HIV-1 Seroconversion Panel PRB975
|
|
- Nickolas Stafford
- 6 years ago
- Views:
Transcription
1 Seroconversion OVERVIEW is a five member HIV Seroconversion collected from a single donor over a 14 day period in 2002, prior to antibody seroconversion. -03 is a challenging sample for HIV RNA assays, and the panel clearly demonstrates improvement in sensitivity with the introduction of the 4 th generation tests. s are undiluted aliquots from plasma units. No preservatives were added. CAUTION: Potentially infectious materials. Follow Universal Precautions. Some panel members were found positive for markers of HIV infection; all were found negative for HBsAg and anti-hcv. For Research Use Only. Not for use in diagnostic procedures. Data are provided for informational purposes. SeraCare does not claim that others can duplicate test results exactly. For assistance, contact SeraCare Technical Support at EVOLUTION OF HIV MARKERS IN EARLY INFECTION s/co HIV Ag Anti-HIV 1/2 Anti-HIV 1 Positive cut-off RNA 3.0E E E E E E+05 copies/ml 0 0.0E Since 1st This graph demonstrates the evolution of early HIV infection, illustrated with test results over time for different analytes or analyte combinations. Page 1 of 5 March
2 Seroconversion HIV RNA (copies/ml) Since 1 st Fiebig Stage 1 RealTime RNA m2000 Roche COBAS AmpliPrep COBAS TaqMan Test v 2.0 Siemens Versant RNA 3.0 Assay (bdna) May-02 0 NA BLD BLD BLD May-02 2 NA BLD BLD BLD May-02 7 I 5.7 x x 10 2 BLD May-02 9 I 7.8 x x x May II 8.1 x x x 10 5 Test 25-Jan Jan Jan-12 Test Site RL SC RL Kit Part Code 6L A/B Kit Lot No P07463 D088 Kit Exp. 31-Dec Aug-12 6-Jun-12 Kit Regulatory Status IVD IVD IVD 1 Fiebig stages are categories that define phases of early HIV infection. See Fiebig EW, et al. Dynamics of HIV viremia and antibody seroconversion in plasma donors: implications for diagnosis and staging of primary HIV infection. AIDS 2003, 17:1871-9, and Lee HY, et al. Modeling sequence evolution in acute infection. JTB 2009, 261: HIV Antigen Perkin Elmer biomerieux Alliance VIDAS HIV p24 II pg/ml 1 p24 Ag ELISA s/co May-02 0 < May-02 2 < May-02 7 < May-02 9 < May Test 12-Mar-12 9-Feb-12 Test Site RL SC Kit Part Code NEK050A Kit Lot No Kit Exp. 17-Jul-12 1-Oct-12 Kit Regulatory Status CE RUO 1 Quantitative HIV Antigen results are means of duplicates expressed pg/ml. s 3.0 are considered reactive and noted in red. 2 Immunoassay results are means of duplicates expressed as signal to cutoff ratios (s/co). Ratios 1.0 are considered reactive and noted in red. Page 2 of 5 March
3 Seroconversion HIV Antigen/Antibody (s/co) 1 ARCHITECT AxSYM PRISM Genscreen Ultra HIV Ag/Ab May May May May May Test 30-Jan-12 6-Feb-12 6-Feb-12 6-Feb-12 Test Site RL RL RL SC Kit Part Code 2P36 2G G Kit Lot No LI LF L100 1F1068 Kit Exp. 30-Apr May Nov Nov-12 Kit Regulatory Status CE CE CE CE HIV Antigen/Antibody GS HIV Ag/Ab EIA s/co 1 Murex HIV Ag/Ab Combination s/co 2 Alere Determine /2 Ag/Ab HIV Ag Alere Determine /2 Ag/Ab HIV Ab May NEG NEG May NEG NEG May NEG NEG May NEG NEG May POS NEG Test 15-Mar Jan-12 5-Mar-2012 Test Site SC RL SC Kit Part Code G D26-46 Kit Lot No. 315FJJ-02 D ALCE Kit Exp. 27-Sep Dec Nov-12 Kit Regulatory Status IVD CE CE 1 Immunoassay results are means of duplicates expressed as signal to cutoff ratios (s/co). Ratios 1.0 are considered reactive and noted in red. 2 Immunoassay results are a single result expressed as signal to cutoff ratios (s/co). Ratios 1.0 are considered reactive and noted in red. Page 3 of 5 March
4 Seroconversion HIV Antibody (s/co) 1 Avioq Microelisa System GS /HIV-2 Plus O EIA Siemens HIV 1/O/2 Enhanced ADVIA Centaur May < May < May < May < May <0.05 Test 27-Jan Jan-12 1-Feb-12 Test Site SC SC RL Kit Part Code Kit Lot No. J FBB Kit Exp. 12-Oct May Apr-12 Kit Regulatory Status IVD IVD IVD 1 Immunoassay results are means of duplicates expressed as signal to cutoff ratios (s/co). Ratios 1.0 are considered reactive and noted in red. HIV Confirmatory Since 1 st GS GS Calypte/MAXIM Calypte/MAXIM May-02 0 No Bands Neg No Bands Neg May-02 2 No Bands Neg No Bands Neg May-02 7 No Bands Neg No Bands Neg May-02 9 No Bands Neg No Bands Neg May No Bands Neg No Bands Neg Test 9-Feb-12 6-Feb-12 Test Site SC SC Kit Part Code Kit Lot No A Kit Exp. 24-Jun Nov-12 Kit Regulatory Status IVD IVD Page 4 of 5 March
5 Seroconversion HIV Confirmatory Innogenetics INNO-LIA HIV I/II Innogenetics INNO-LIA HIV I/II May-02 0 No Bands NEG May-02 2 No Bands NEG May-02 7 No Bands NEG May-02 9 No Bands NEG May No Bands NEG Test 12-Mar-12 Test Site RL Kit Part Code INX22206 Kit Lot No Kit Exp. 31-Jan-13 Kit Regulatory Status CE The Product Insert for this panel in PDF form can be found at A printed copy of the Package Insert or Data Sheet may be requested by at info@seracare.com, or by phone at ASK ABOUT RELATED SERACARE PRODUCTS ACCURUN independent quality controls SeraCon and other processed plasma products Global Patient Sample (GPS) Program access to a vast and evolving inventory of single test patient samples Page 5 of 5 March
HIV-1 Seroconversion Panel PRB973
A SERACARE PANEL PRODUCT INTENDED USE The is a group of serial bleeds from an individual plasma donor during seroconversion. This panel is intended for use by diagnostics manufacturers and clinical laboratorians
More informationAccuVert HIV-1 Seroconversion Panel PRB974 ( )
PACKAGE INSERT PRB974 (0600-0258) INTENDED USE PRB974 (0600-0258) is a group of serial bleeds from an individual plasma donor during seroconversion. This panel is intended for use by diagnostics manufacturers
More informationExpression of HIV-1 Markers During Progression of Infection E E E Days Since 1st Bleed
Seroconversion OVERVIEW HIV-1 AccuVert TM Seroconversion PRB970 is a 4 member, 1.0 ml per vial panel of undiluted, naturally-occurring plasma samples. members represent serial bleeds collected from a single
More informationHIV-1 Seroconversion Panel
OVERVIEW This Data Sheet contains test results specific for HIV-1. s are undiluted aliquots from plasma units collected from a single donor. No preservatives were added. CAUTION: Potentially infectious
More informationHIV-1 Seroconversion Panel
A SERACARE PANEL PRODUCT Seroconversion INTENDED USE The Seroconversion is a group of serial bleeds from an individual plasma donor during seroconversion. This is intended for use by diagnostics manufacturers
More informationAccuSet Anti-HIV-1 Mixed Titer Performance Panel
signal to cut-off (s/co) DATA SHEET OVERVIEW PRB205(M3) is a modified 16-member panel originating from Anti- HIV-1 Mixed Titer PRB205(M2). Panel members 3, 5, 6, 17, 21, 22, 23, 24, and 25 from the original
More informationHIV-1 Seroconversion Panel PRB964
A SERACARE PANEL PRODUCT Seroconversion INTENDED USE The is a group of serial bleeds from an individual plasma donor during seroconversion. This is intended for use by diagnostics manufacturers and clinical
More informationAccuSet Anti-HIV-1 Mixed Titer Performance Panel
PACKAGE INSERT PRB205(M3) / (0800-0379) INTENDED USE The Performance Panel PRB205(M3) / (0800-0379) is intended for use by diagnostics manufacturers and clinical laboratorians to evaluate their HIV-1 test
More informationHIV-1 AccuVert Seroconversion Panel (PRB966) / Batch #
s/co c/ml DATA SHEET OVERVIEW 0600-0248 (PRB966) is a 10-member panel of undiluted, naturally occurring plasma samples. Panel members represent serial bleeds collected from a single patient over the course
More informationAccuSet HCV Performance Panel
Signal to cutoff (s/co) DATA SHEET OVERVIEW AccuSet HCV (0810-0204) is a 25-member validation panel of undiluted, naturally occurring plasma samples (1 vial per member, 1.0 ml per vial). Panel members
More informationAccuSet HIV-1/2 Performance Panel
OVERVIEW AccuSet HIV-1/2 (0800-0380) is a 13-member validation panel of undiluted, naturally occurring plasma samples (1 vial per member, 1.0 ml per vial). Panel members represent bleeds from multiple
More informationHIV-1 AccuVert TM Seroconversion Panel
PACKAGE INSERT PRB954 (0600-0238) INTENDED USE The is intended for use by diagnostic manufacturers, researchers, and clinical laboratories to develop, evaluate, or troubleshoot test methods. Characterized
More informationAccuVert HIV-1 Seroconversion Panel PRB955 ( ) / Batch #
Signal to cutoff (s/co) Copies per ml (c/ml) OVERVIEW AccuVert is a 5-member validation panel of undiluted, naturally occurring plasma samples (1 vial per member, 1.0 ml per vial). Panel members represent
More informationAccuVert HBV Seroconversion Panel PHM941(M) ( )
PACKAGE INSERT PHM941(M) (0605-0061) INTENDED USE PHM941(M) (0605-0061) is a group of serial bleeds from an individual plasma donor during HBV seroconversion. This panel is intended for use by diagnostics
More informationAccuSet HBV Worldwide Performance Panel
PACKAGE INSERT 0805-033 INTENDED USE The is intended for use by diagnostic manufacturers, researchers, and clinical laboratories to develop, evaluate, or troubleshoot HBV test methods. Characterized samples
More informationParvovirus B19 Mixed Titer Performance Panel PVP201
A SERACARE PANEL PRODUCT INTENDED USE The is a panel of naturally occurring plasma specimens. This panel is intended for use by diagnostic manufacturers and clinical laboratories to evaluate their Parvovirus
More informationAccuSet Autoimmune Performance Panel
PACKAGE INSERT 0840-0001 INTENDED USE The 0840-0001 is intended for use by diagnostic manufacturers, researchers, and clinical laboratories to develop, evaluate, or troubleshoot autoimmune related test
More informationHIV Serology Quality Assessment Program Revised Summary for Panel HIVSER 2017Oct27
National Laboratory for HIV Reference Services National HIV and Retrovirology Laboratories National Microbiology Laboratory Public Health Agency of Canada HIV Serology Quality Assessment Program Revised
More informationHIV Serology Quality Assessment Program Summary for Panel HIVSER 2017Apr19
National Laboratory for HIV Reference Services National HIV and Retrovirology Laboratories National Microbiology Laboratory Public Health Agency of Canada HIV Serology Quality Assessment Program Summary
More informationHIV Serology Quality Assessment Program Summary for Panel HIVSER 2018Apr19
National Laboratory for HIV Reference Services National HIV and Retrovirology Laboratories National Microbiology Laboratory Public Health Agency of Canada HIV Serology Quality Assessment Program Summary
More informationDiagnostic Tests for HIV
Mountain West AIDS Education and Training Center Diagnostic Tests for HIV David Spach, MD Principal Investigator, Mountain West AETC Professor of Medicine, University of Washington Last Updated: June 22,
More information100 Abbott Park Road Abbott Park, IL Trade Name: ARCHITECT HIV Ag/Ab Combo Assay Approved Date: 18-JUN-2010
Currently Approved CBER Device Premarket Applications (PMAs) As of Nov 10, 2014 Sorted by Applicant Name BP090080-0 BP060002-0 BP120037-0 BP090022-0 BP090032-0 BP040046-0 BP100064-0 BP140120-0 Abbott Laboratories
More informationHIV Serology Quality Assessment Program Summary for Panel HIVS Oct22
National Laboratory for HIV Reference Services National HIV and Retrovirology Laboratories National Microbiology Laboratory Public Health Agency of Canada HIV Serology Quality Assessment Program Summary
More information2018 HIV and HCV Diagnostic Testing Survey
2018 HIV and HCV Diagnostic Testing Survey This survey is designed to capture the 2017 HIV and HCV testing practices in state and local public health laboratories (PHL). The results of the survey will
More informationRoutine HIV Testing Community of Practice Session #2
Routine HIV Testing Community of Practice Session #2 Presenters: Denver Prevention Training Center Broward Community & Family Health Centers, Inc. 20 March 2016 Communities of Practice Routine HIV Testing
More informationARCHITECT HIV Ag/Ab Combo: Moving HIV Diagnostics Forward in the U.S.
ARCHITECT HIV Ag/Ab Combo: Moving HIV Diagnostics Forward in the U.S. Catherine Brennan, Ph.D. Research Fellow Infectious Diseases Research Abbott Diagnostics 1 Agenda ARCHITECT HIV Ag/Ab Combo Assay What
More informationHuman Immunodeficiency Virus Serology
Participant No: _ Human Immunodeficiency Virus Serology Survey No: RT :20 Please print the document labelled Clinical Notes & Test Instructions and enter your results via myqap. Kit Information Please
More informationWHO Prequalification of In Vitro Diagnostics Programme
WHO Prequalification of In Vitro Diagnostics Programme International HIV/Viral Hepatitis Co-Infection Satellite Meeting 19 July 2014, Melbourne Anita Sands Prequalification Diagnostics Team Department
More informationResearch Article Decision on conducting HCV Immunoblot and HCV Viral Load Tests Dependent upon the Result of the Screening Tests
IBIMA Publishing Journal of Virology & Microbiology http://www.ibimapublishing.com/journals/jvm/jvm.html Vol. 2013 (2013), Article ID 332501, 7 pages DOI: 10.5171/2013.332501 Research Article Decision
More informationEvolution of HIV Diagnostics. Goals for the 2010 Conference. Bernard M. Branson, M.D. CDC Division of HIV/AIDS Prevention
Evolution of HIV Diagnostics and Goals for the 2010 Conference Bernard M. Branson, M.D. Associate Director for Laboratory Diagnostics CDC Division of HIV/AIDS Prevention Evolution or other influences like
More informationNew HIV Tests and Algorithm: A change we can believe in
New HIV Tests and Algorithm: A change we can believe in Esther Babady, PhD, D (ABMM) Memorial Sloan-Kettering Cancer Center New York, New York Learning Objectives After this presentation you should be
More informationT pallidum. Table of contents
An assessment of Point of Care Tests for Hepatitis B, Hepatitis C, HIV and Syphilis for use in an Operational Environment to Provide Emergency Transfusion Support Microbiological Diagnostics Assessment
More informationUsing all the data: Immunoassay signal-to-cutoff values provide useful information that should be considered in HIV diagnostic
Using all the data: Immunoassay signal-to-cutoff values provide useful information that should be considered in HIV diagnostic algorithms KP Delaney, M Pentella, B Bennett, and K Landgraf for the CDC/APHL
More informationInfectious Disease Testing. ULTRA Product Line. Safety is not a Matter of Chance
Infectious Disease Testing ULTRA Product Line Safety is not a Matter of Chance ULTRA Product Line The best answer for HBV, HCV and HIV screening: a global automated solution for safe results. Monolisa
More informationHIV Testing Technology and the Latest Algorithm
HIV Testing Technology and the Latest Algorithm David Warshauer, PhD, D(ABMM) Deputy Director, Communicable Diseases Wisconsin State Laboratory of Hygiene HIV Testing has changed over time Patients with
More informationComplicated viral infections
Complicated viral infections Clinical case discussion Diagnostic dilemmas NSW State Reference Laboratory for HIV St Vincent s Hospital Sydney Diagnostic dilemmas Indeterminate or discordant serology (western
More informationFINAL REPORT HBV Serology External Quality Assessment Scheme
FINAL REPORT HBV Serology External Quality Assessment Scheme Programme codes: HBVC4310, HBVC435 Panel ID: 2008/Mar/11 HBV Serology EQAS Panel ID 2008/Mar/11 Page 1 of 9 The NRL is a: NATA-accredited proficiency
More informationWithin 14 days at 2-8⁰C. DO NOT FREEZE WHOLE BLOOD Micro Typing Systems 50 µl plasma
Test Name *Minimum Collection Tubes Sample Stability ABO/Rh Blood Typing 50 µl cells EDTA whole blood (lavender-top) Within 14 days at 2-8⁰C. DO NOT FREEZE WHOLE BLOOD Micro Typing Systems 50 µl plasma
More informationSupplementary Online Content
Supplementary Online Content Peters PJ, Westheimer E, Cohen S, et al. Screening yield of HIV antigen/antibody combination and pooled HIV RNA testing for acute HIV infection in a high-prevalence population.
More informationHIV SELF-TESTING AFRICA
UNITAID PSI HIV SELF-TESTING AFRICA Zambart: Interim Results of Clinical Performance Study Alwyn Mwinga Overview of Presentation Study Objectives Clinical Performance study Visual stability study Progress
More informationHTLV Serology Quality Assessment Program Summary for Panel HTLS Oct22
National Laboratory for HIV Reference Services National HIV and Retrovirology Laboratories National Microbiology Laboratory HTLV Serology Quality Assessment Program Summary for Panel HTLS425 2015Oct22
More informationSerology and International units
Serology and International units L. Grangeot-Keros, National Reference Laboratory for Rubella, Virology Department, A. Béclère Hospital, Clamart, France Detection of rubella-specific IgG antibody Assays
More informationFlu Watch. MMWR Week 3: January 14 to January 20, and Deaths. Virologic Surveillance. Influenza-Like Illness Surveillance
Flu Watch MMWR Week 3: January 14 to January 2, 218 All data are provisional and subject to change as more reports are received. Geographic Spread South Carolina reported widespread activity this week.
More informationDraft Report WHO evaluation of HIV 1/2 STAT-PAK (Chembio Diagnostic Systems Inc)
Date: 6 January 2012 Draft Report WHO evaluation of HIV 1/2 STAT-PAK (Chembio Diagnostic Systems Inc) WHO Collaborating Centre for HIV/AIDS Diagnostic and Laboratory Support Department of Clinical Sciences
More informationHIV Viral Load Quality Assessment Program Summary for Panel HIVVL 2018Oct26
1 National Laboratory for HIV Reference Services National HIV and Retrovirology Laboratories National Microbiology Laboratory Public Health Agency of Canada HIV Viral Load Quality Assessment Program Summary
More informationOverview of HIV Testing Practices and Technology
Overview of HIV Testing Practices and Technology 2019 HIV Diagnostics Conference March 25 th, 2019 Michele Owen, Ph.D National Center for HIV/AIDS, Viral Hepatitis, STD and TB Prevention Centers for Disease
More informationFlu Watch. MMWR Week 4: January 21 to January 27, and Deaths. Virologic Surveillance. Influenza-Like Illness Surveillance
Flu Watch MMWR Week 4: January 21 to January 27, 218 All data are provisional and subject to change as more reports are received. Geographic Spread South Carolina reported widespread activity this week.
More informationSchedule of Accreditation
Schedule of Accreditation Organisation Name National Virus Reference Laboratory INAB Reg No 326MT Contact Name Eimear Malone Address University College Dublin, Belfield, Dublin Contact Phone No 01-7161319
More information1 st and 2 nd Generation EIA
HIV Diagnostic Tests Bernard M. Branson, M.D. Associate D irector for Laboratory D iagnostics Division of HIV/AIDS Prevention Centers for D isease Control & Prevention The views expressed in this presentation
More informationFINAL REPORT HBV Serology External Quality Assessment Scheme
FINAL REPORT HBV Serology External Quality Assessment Scheme Programme codes: HBVC4310, HBVC435 Panel ID: 2008/Oct/28 HBV Serology EQAS Panel ID 2008/Oct/28 Page 1 of 11 The NRL is a: NATA-accredited proficiency
More informationTrends in molecular diagnostics
Trends in molecular diagnostics Detection of target genes of interest Quantification Infectious diseases HIV Hepatitis C & B TB / MAC Cytomegalovirus Herpes simplex Varicella zoster CT/GC HPV Profiling
More informationSituation of XMRV and Blood Transfusion. Celso Bianco, MD ISBT Working Party on TTID Lisbon, June 19, 2011
Situation of XMRV and Blood Transfusion Celso Bianco, MD ISBT Working Party on TTID Lisbon, June 19, 2011 Lombardi et al. Science 326, 585 (2009) Conclusions: CFS and XMRV XMRV found in 67% of CFS patients
More informationCurators of the University of Missouri - Combined January 1, 2016 through December 31, 2016
Cost Management Report Delta Dental Network Coverage Network Utilization Discount Delta Dental PPO Network 28.3% 29.4% Delta Dental Premier Network 67.0% 12.0% Total 95.3% Savings Categories $ % of Net
More informationHIV Update in Laboratory Testing. Patricia Slev, PhD, D(ABCC)
HIV Update in Laboratory Testing Patricia Slev, PhD, D(ABCC) Objectives Explain the advances in HIV diagnostics, including fourth generation Ag/Ab combination HIV screening assays Describe the new CDC
More informationWHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT. Product: Murex HIV Ag/Ab Combination Number: PQDx
WHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT Product: Murex HIV Ag/Ab Combination Number: PQDx 0144-043-00 Abstract Murex HIV Ag/Ab Combination with product codes 7G79-09 (GE41,
More informationWHO PROTOCOL FOR PERFORMANCE LABORATORY EVALUATION OF HIV SEROLOGY ASSAYS
WHO PROTOCOL FOR PERFORMANCE LABORATORY EVALUATION OF HIV SEROLOGY ASSAYS WHO/EMP/RHT/PQT/2017.xx Page 1 of 17 World Health Organization 2017 Some rights reserved. This work is available under the Creative
More informationFAQs about Provider Profiles on Breast Cancer Screenings (Mammography) Q: Who receives a profile on breast cancer screenings (mammograms)?
FAQs about Provider Profiles on Breast Cancer Screenings (Mammography) Q: Who receives a profile on breast cancer screenings (mammograms)? A: We send letters and/or profiles to PCPs with female members
More informationEQAS. Hemoglobin Program (BC80) Cycle 12: December 2014 December 2015 Sample No: 1 Sample Date: 17 Dec 14. Exceptions. Customer Information
(BC80) : December 2014 December 20 Exceptions None at this time. Legend: No Warnings Missing Result Late Results < < > * Amended Result (per participant s request) News Customer Information Please refer
More informationConfirmatory Testing Algorithm. Routine Donor Testing Algorithm
Confirmatory Testing Algorithm Blood Confirmatory ABO/Rh Beckman Coulter PK-ABO/Rh Immucor NEO ABO/Rh Immucor NEO ABO/Rh Immucor Manual ABO/Rh Typing Immucor Manual ABO/Rh Typing Discrepancy Resolution
More informationOpportunities Created by Diagnostic HCV and HIV Nucleic Acid Tests
Opportunities Created by Diagnostic HCV and HIV Nucleic Acid Tests Ann Winters, MD Medical Director, Viral Hepatitis Program, Bureau of Communicable Disease, New York City Department of Health and Mental
More informationISBT WP-TTID Annual Report for Subgroup on Virology Drs. Michael Busch, Kurt Roth and Susan Stramer
ISBT WP-TTID Annual Report for Subgroup on Virology Drs. Michael Busch, Kurt Roth and Susan Stramer Questionnaire on NAT Screening of Blood Donations for an International Forum on 10 years of NAT Screening
More informationHigh Rate of Missed HIV Infections in Individuals With Indeterminate or Negative HIV Western Blots Based on Current HIV Testing Algorithm in China
Journal of Medical Virology 88:1462 1466 (2016) High Rate of Missed HIV Infections in Individuals With Indeterminate or Negative HIV Western Blots Based on Current HIV Testing Algorithm in China Man-Qing
More informationAdvantages and disadvantages of different types of FDA-approved HIV immunoassays used for screening by generation and platform*
Advantages and disadvantages of different types of FDA-approved HIV immunoassays used for screening by generation and platform* HIV immunoassays grouped by generation, platform, and CLIA complexity + Advantages
More informationWHO Prequalification of Diagnostics Programme PUBLIC REPORT
WHO Prequalification of Diagnostics Programme PUBLIC REPORT Product: Murex HBsAg Version 3 with Murex HBsAg Confirmatory Version 3 Number: PQDx 0121-043-00 Abstract Murex HBsAg Version 3 with Murex HBsAg
More informationA Case of False-Positive Test Results in a Pregnant Woman of Unknown HIV Status at Delivery
A Case of False-Positive Test Results in a Pregnant Woman of Unknown HIV Status at Delivery Pascale Akl, MD, 1 Kenneth E. Blick, PhD 1* Lab Med Spring 2014;45:259-263 DOI: 10.1309/LMAAGVXK05LUWOQN ABSTRACT
More informationWHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT. Product: Bioelisa HIV 1+2 Ag/Ab Number: PQDx
WHO Prequalification of In Vitro Diagnostics Programme PUBLIC REPORT Product: Bioelisa HIV 1+2 Ag/Ab Number: PQDx 0183-060-00 Abstract Bioelisa HIV 1+2 Ag/Ab with product codes 3000-1172 and 300-1173,
More informationLearning Objectives. New HIV Testing Algorithm from CDC. Overview of HIV infection and disease 3/15/2016
New HIV Testing Algorithm from CDC ASCLS-Michigan March 31, 2016 Dr. Kathleen Hoag Learning Objectives Following attendance and review of material provided, attendees will be able to: 1. Describe the new
More informationSUPPLIER/MANUFACTURER PERFORMANCE REPORT
80/30 MOO 8 PHAHOLYOTHIN RD., T.KUKHOT, A.LUMLOOKKAR, PATHUMTHANI 30, THAILAND TEL : (66-) 9958 9, 995330 FAX : (66-) SUPPLIER/MANUFACTURER PERFORMANCE REPORT 80/30 MOO 8 PHAHOLYOTHIN RD., T.KUKHOT, A.LUMLOOKKAR,
More informationWHO list of prequalified in vitro diagnostic products
WHO list of in vitro diagnostic products : Rest of the world. Regulatory version applied to products not approved by stringent/mature NRAs or not regulated Last update: 8 April 2016 Year 2016 HIV RDT OraQuick
More informationQuality Control Solutions
Quality Control Solutions 1 CONTENT QCONNECT 3 ABOUT DIAMEX 6 ABOUT NRL 7 ABOUT EXACT DIAGNOSTICS 7 PRODUCTS 8 SEROLOGY MULTIMARKER RANGE 10 SEROLOGY SINGLE ANALYTE RANGE 16 NAT CONTROL RANGE 19 EXACT
More information18 Week 92% Open Pathway Recovery Plan and Backlog Clearance
18 Week 92% Open Pathway Recovery Plan and Backlog Clearance Page 1 of 6 17.05.2012 1.0 Background 18-Week 92% Open Pathway RECOVERY PLAN The Trust has achieved compliance against the admitted and non-admitted
More informationP0078 SeraQ ARCHITECT P0078
P0078 SeraQ ARCHITECT P0078 The kit insert contains a detailed protocol and should be read carefully before testing the run control to ensure optimal performance Table of contents Intended Use... 3 Key
More informationDiagnostic Methods of HBV infection. Zohreh Sharifi,ph.D of Virology Research center, Iranian Blood Transfusion Organization (IBTO)
Diagnostic Methods of HBV infection Zohreh Sharifi,ph.D of Virology Research center, Iranian Blood Transfusion Organization (IBTO) Hepatitis B-laboratory diagnosis Detection of HBV infection involves
More informationWith the aim of continuous improvement of our products, Biokit increases the shelf life of bioelisa HIV 1+2 Ag/Ab from 10 to 12 months.
1 NEWS BK NEWS # 377 /MKT DATE : 18-01-2016 TITLE : SHELF-LIFE EXTENSION OF bioelisa HIV 1+2 Ag/Ab With the aim of continuous improvement of our products, Biokit increases the shelf life of bioelisa HIV
More informationOverview of the Radiation Exposure Doses of the Workers at Fukushima Daiichi Nuclear Power Station
Click here for the corrections made < Reference > December 3, 212 Tokyo Electric Power Company Overview of the Radiation Exposure Doses of the Workers at Fukushima Daiichi Nuclear Power Station * As of
More informationMcLean ebasis plus TM
McLean ebasis plus TM Sample Hospital (0000) Report For Qtr HBIPS Core Measures McLean Hospital 115 Mill Street Belmont, MA 02478 1 2012 Department of Mental Health Services Evaluation Tel: 617-855-3797
More informationFGSZ Zrt. from 28 February 2019 till 29 February 2020 AUCTION CALENDAR: YEARLY YEARLY BUNDLED AT CROSS BORDER POINTS
AUCTION CALENDAR: YEARLY YEARLY BUNDLED AT CROSS BORDER POINTS FIRM CAPACITY - First Monday of July 01.06.2019* 01.07.2019 07:00 01.10.2019 04:00 01.10.2020 04:00 2019/2020 01.10.2020 04:00 01.10.2021
More informationTri-County Opioid Safety Coalition Data Brief December 2017 Clackamas, Multnomah, and Washington Counties
Medicaid-Funded Alternative Treatment for Back Pain in the Tri-County Region Key Findings The percentage of members with a back pain diagnosis who received an alternative treatment increased from 29% in
More informationLaboratory for Clinical and Biological Studies, University of Miami Miller School of Medicine, Miami, FL, USA.
000000 00000 0000 000 00 0 bdna () 00000 0000 000 00 0 Nuclisens () 000 00 0 000000 00000 0000 000 00 0 Amplicor () Comparison of Amplicor HIV- monitor Test, NucliSens HIV- QT and bdna Versant HIV RNA
More informationQuit Rates of New York State Smokers
Quit Rates of New York State Smokers Sara M. Abrams, MPH Data Manager NYS Smokers Quitline Sara.Abrams@roswellpark.org September 6, 20 Presentation Outline Basic Quitline Service How Quit Rates are defined
More informationFrom Analytics to Action
From Analytics to Action Overview So, what are we talking about here? How to make incremental changes to your digital content that will result in positive user actions Overview Rooted in the hard sciences
More informationSouth Plains Emergency Medical Services, Inc. P.O. Box Lubbock, Texas 79453
South Plains Emergency Medical Services, Inc. P.O. Box 53597 Lubbock, Texas 79453 June 28, 2017 TO: SPEMS EMS Services SUBJECT: SPEMS PARAMEDIC PROTOCOL VARIANCE With the ongoing medication shortages,
More informationCurators of the University of Missouri - Combined January 01, 2013 through December 31, 2013 Cost Management Report
Cost Management Report Program Design Specifics Standard Claims Management SAVINGS CATEGORIES SAVINGS RESULTS % OF NET SUBMITTED DOLLARS % OF PAID DOLLARS Deductible Applied $1,296,627 5.68% 9.78% Patient
More informationHIV Viral Load Quality Assessment Program Summary for Panel HIVVL 2017Oct27
1 The National Laboratory for HIV Reference Services is Accredited to ISO 15189 and ISO 17043 National Laboratory for HIV Reference Services National HIV and Retrovirology Laboratories National Microbiology
More informationSeasonality of influenza activity in Hong Kong and its association with meteorological variations
Seasonality of influenza activity in Hong Kong and its association with meteorological variations Prof. Paul Chan Department of Microbiology The Chinese University of Hong Kong Mr. HY Mok Senior Scientific
More informationVQA HIV DNA Control SOP Version 5.0 HIV DNA Testing 13 March 2012
1. PRINCIPLE 1.1. The Virology Quality Assurance (VQA) Laboratory provides external cell pellet controls for use in the validation of assays that detect HIV proviral DNA. 1.2. HIV seronegative peripheral
More informationHTLV Serology Quality Assessment Program Summary for Panel HTLVSER 2017Apr19
National Laboratory for HIV Reference Services National HIV and Retrovirology Laboratories National Microbiology Laboratory HTLV Serology Quality Assessment Program Summary for Panel HTLVSER 2017Apr19
More informationErgebnisse der Abfrage zu NAT-only positiven Befunden beim Blutspendescreening (NAT yield) Micha Nübling, PEI
Ergebnisse der Abfrage zu NAT-only positiven Befunden beim Blutspendescreening (NAT yield) Micha Nübling, PEI NAT for cellular blood components in Germany Definition of minimal NAT sensitivity limit (ID)
More informationCALIBRATION OF ANALYTICAL STANDARDS FOR HBV-DNA, HCV-RNA AND HIV-1 RNA IN GENOME COPIES BY A REFERENCE METHOD
CALIBRATION OF ANALYTICAL STANDARDS FOR HBV-DNA, HCV-RNA AND HIV-1 RNA IN GENOME COPIES BY A REFERENCE METHOD AAJ van Drimmelen, E.R. Bax and W.G.V. Quint, BioQControl (BQC), Delft Diagnostic Laboratories
More informationThe Latest in HIV Tests: What Do the Results Mean?
The Latest in HIV Tests: What Do the Results Mean? Bernard M. Branson MD Principal Consultant, Scientific Affairs LLC Atlanta, Georgia Objectives At the end of this workshop, participants will be able
More informationNational Screening laboratory Sanquin The use of NAT in blood donation screening in The Netherlands. TransMed conference Bhopal 18 November 2016
Dr. Anton van Weert National Screening laboratory Sanquin The use of NAT in blood donation screening in The Netherlands TransMed conference Bhopal 18 Introduction Thank you! Anton van Weert, PhD, MBA Manager
More informationHBV-DNA reference panels
HBV-DNA reference panels The kit insert contains a detailed protocol and should be read carefully before testing the run control to ensure optimal performance Table of contents Overview HBV-DNA panels
More informationSleep Market Panel. Results for June 2015
Sleep Market Panel Results for June 2015 Notes: o This is a monthly trending report of panel member data along with additional analysis by: Sleep labs affiliated with Hospitals vs. Independent Labs o Hospital
More informationKhalid Alquthami (Correspondence) Regional Lab, Makkah. Saudi Arabia
1 Regional Lab, Makkah. Saudi Arabia stract: Clinical specificity and genotype/subtype detection of viruses using the Cobas TaqScreen MPX system V 2.0, which is a nucleic acid test (NAT) that uses multiples
More informationCustomer Service and Ordering Address Biologicals Quality Control B.V. Droogmakerij 31h 1851 LX Heiloo The Netherlands
PRODUCT CATALOGUE Customer Service and Ordering Address Biologicals Quality Control B.V. Droogmakerij 31h 1851 LX Heiloo The Netherlands Communication +31 72 202 07 30 +31 72 202 07 31 sales@bioqcontrol.com
More informationMicropathology Ltd. University of Warwick Science Park, Venture Centre, Sir William Lyons Road, Coventry CV4 7EZ
www.micropathology.com info@micropathology.com Micropathology Ltd Tel 24hrs: +44 (0) 24-76 323222 Fax / Ans: +44 (0) 24-76 - 323333 University of Warwick Science Park, Venture Centre, Sir William Lyons
More informationto be notified: all parties involved in the graduated plan procedure. Annexes
Paul-Ehrlich-Institut Postfach 63207 Langen, Germany To all marketing authorisation holders of cellular blood preparations and therapeutic single plasmas as well as authorisation holders of stem cells
More informationURGENT FIELD SAFETY NOTICE FSCA3193. Etest Ceftriaxone TXL32 (Ref , ) SPB Packaging
16 January 2017 Attachment 3 URGENT FIELD SAFETY NOTICE FSCA3193 Etest Ceftriaxone TXL32 (Ref. 412302, 412303) SPB Packaging Dear This letter is intended for all ETEST Ceftriaxone TXL32 (Ref. 412302, 412303)
More informationA Summary of Clinical Evidence
A Summary of Clinical Evidence Supporting the use of the Alere Determine HIV-1/2 Ag/Ab Combo Rapid Test to assist in the diagnosis of Human Immunodeficiency Virus (HIV) TAP HERE TO SEE THE PRODUCTS Table
More information