Discrete Industrial Analyzer System Reagents for Food and Other Sample Materials
|
|
- Annis Glenn
- 6 years ago
- Views:
Transcription
1 Discrete Industrial Analyzer System Reagents for Food and Other Sample Materials Analyte Code Product name Max. nbr. of tests/kit (1 Method Sample matrix Interference filter nm (2 Test ranges Unit Acetaldehyde Acetaldehyde (3 Acetaldehyde standard, 100 mg/l 250 Enzymatic test with acetaldehyde beverage 340 / 2500 mg/l Acetic acid Acetic Acid (4 Acetic acid Acetic Acid (ACS) 150 Enzymatic test with acetate kinase Enzymatic test with acetylcoenzyme A synthetase (ACS) 340 / g/l 340 / g/l AlphaAmino Nitrogen (3 AlphaAmino Nitrogen (NOPA) NOPA Standard, 150 mg/l Colorimetric test with OPA (o Phthaldialdehyde) and NAC (Nacetylcysteine) 340 / 700 (750) 20 mg/l AlphaAmylase AlphaAmylase 780 Enzymatic test with ethylidenepnpg7 (EpNPG7) as the substrate Enzyme, detergent 405 / U/l Ammonia (4 Ammonia Ammonia Enzymatic test with glutamate 340 / mg/l LAscorbic acid LAscorbic acid 250 Colorimetric test with the tetrazolium salt MTT 575 / mg/l LAsparagine ( LAsparagine/LAsparticAcid 350 Washfluid Enzymatic test with malate hydrogenase and Lasparaginase 340 / mg/l D16080_0217 Page 1 of 6
2 LAspartic Acid (5 LAsparagine/LAsparticAcid 350 Bitterness ( BC System liquid BC Diluent BC Eluent 360 Enzymatic test with malate hydrogenase Column extraction of bittering components from beer and wort and subsequent photometric determination Calcium Calcium (Ca) 350 Colorimetric test with Arsenazo III Citric Acid Citric acid 250 Enzymatic test with citrate lyase Cholesterol Copper Ethanol DFructose (1,3/1,4)BetaGlucan Cholesterol Food (3 Cholesterol Food Std, 2000 mg/l ( ( (3 Copper Copper Standard, 5 mg/l Washfluid Ethanol Alcohol Standard. 0.5 g/l DFructose Sugar Combination Std, g/l BetaGlucan (High MW) BetaGlucan Standard, 500 mg/l DGluconic Acid DGluconic Acid Enzymatic test with cholesterol oxidase, peroxidase and with colorimetric indicator chinonimin Colorimetric test with DiBrPAESA Enzymatic test with alcohol Enzymatic test with hexokinase, phosphoglucose isomerase and glucose6phosphate Novel colorimetric test Enzymatic test with 6Pgluconate and gluconate kinase Beer, Wort 340 / mg/l 275 / 5100 BU 660 / mg/l 340 / mg/l 540 / 20 mg/l 600 / mg/l 340 / g/l 340 / g/l 5500 (7 mg/l 405 / mg/l 340 / 750 (700) mg/l D16080_0217 Page 2 of 6
3 DGlucose DGlucose & DFructose DGlucose & DFructose & Sucrose Glycerol ( ( ( ( (3 DGlucose DGlucose Sugar Combination Std, g/l DGlucose+DFructose DGlucose+DFructose Sugar Combination Std, 1.0 g/l DGlucose+DFructose+Sucrose DGlucose+DFructose+Sucrose Sugar Combination Std, 1.5 g/l Glycerol Glycerol Glycerol Standard, 0.2 g/l LGlutamic Acid (5 LGlutamic Acid BetaHydroxybutyric Acid (3 ß Hydroxybutyrate ß Hydroxybutyrate Std, 100 mg/l Enzymatic test with hexokinase and glucose6phosphate Enzymatic test with hexokinase, phosphoglucose isomerase and glucose6phosphate Enzymatic test with betafructosidase (Invertase), hexokinase, phosphoglucose isomerase and glucose6 phosphate Enzymatic test with glycerokinase, ADP dependent hexokinase and glucose6phosphate Enzymatic test with glutamate Enzymatic test with D3 hydroxybutyric and nitrotetrazolium blue Iron Total Iron (Fe) 850 Colorimetric test with Ferene S DIsocitric acid DIsocitric Acid DLactic Acid LLactic Acid ( (3 DLactic Acid Acid Combination Std, 200 mg/l LLactic Acid Acid Combination Std, 200 mg/l Enzymatic test with isocitrate Enzymatic test with Dlactate Enzymatic test with Llactate 340 / g/l 5500 (7 mg/l 340 / g/l 340 / g/l 340 / g/l 492 / g/l 540 / mg/l 600 / mg/l 340 / mg/l 340 / mg/l 340 / mg/l D16080_0217 Page 3 of 6
4 Lactose ( (3 Lactose (Glucose) (8 Lactose (Glucose) (8 Lactose Standard, 1.00 g/l Lipase Lipase 500 Enzymatic test with galactosidase (Lactase), hexokinase and glucose 6phosphate Colorimetric test with methylresorufin Magnesium Magnesium (Mg) 350 Colorimetric test with Xylidyl Blue I LMalic Acid Oxalic Acid ph ( ( ( ( (3 LMalic Acid LMalic Acid Acid Combination Std, g/l Oxalic Acid Oxalic Acid Standard, 45 mg/l ph (Colorimetric) ECM ph 4 Standard ECM ph 7 Standard Polyphenols Total Polyphenol 280 Potassium Potassium Enzymatic test with Lmalate and glutamateoxalacetatetransaminase Enzymatic test with oxalate oxidase Colorimetric test with ph indicator dyes Colorimetric test with Folin Ciocalteau reagent Turbidimetric test with tetraphenylborate Proteins Total Protein (Biuret) 450 Colorimetric test with Biuret Sulfur dioxide Sucrose SO2 Free SO2 Total Sucrose (Total Glucose) (8 Sugar Combination Std, 0.75 g/l 430 Colorimetric test with pararosaniline Colorimetric test with DTNB Enzymatic test with betafructosidase, hexokinase and glucose6phosphate Enzyme, detergent Beer, Wort 340 / g/l 575 / up to 60 mg/100 g 510 / mg/l 340 / 700 (750) g/l 600 / mg/l 575 / ph at 37 C 700 / 500 mg/l as Gallic acid 540 / mg/l 540 / g/l 2150 mg/l 575 / 750 (700) 20 mg/l 405 / 750 (700) 250 (7 mg/l 340 / g/l (7 mg/l D16080_0217 Page 4 of 6
5 Tartaric Acid Tartaric acid (5 480 Colorimetric test with ammonium monovanadate 540 / g/l Total Acids Total Acids (Wine ph 7) Total Acids (Juice ph 8) Colorimetric tests with bromothymol blue 620 / 700 (750) g/l as Tartaric acid g/l as Sulfuric acid g/l as Citric acid Urea (3 Urea (Ammonia) (9 Urea Standard Enzymatic test with urease and glutamate 340 / mg/l NOTE: 1. Number of tests/ kit is test flow dependent number. 2. λ1/λ2 (main/side wavelength in nm), alternative wavelength provided in brackets (λ) 3. Standard solution for method calibration, concentrations are Lot dependent 4. Arena kits only 5. Kit contains a standard solution for calibration 6. Method available for the Gallery Plus Beermaster with BCM analyzer only 7. Separate low range application available 8. DGlucose result is needed for Sucrose and Lactose calculation from assayed Glucose 9. Ammonia result is needed for Urea calculation from assayed Ammonia D16080_0217 Page 5 of 6
6 NIST traceable standards for ECM measurements Parameter Code Product name Kit size ECM ph 2 Standard ECM ph 4 Standard ph ECM ph 7 Standard ECM ph 10 Standard ECM ph 12 Standard ECM Conductivity 0.08 Standard Conductivity (ms/cm) ECM Conductivity 1.4 Standard ECM Conductivity 13 Standard ECM Conductivity 112 Standard Africa Denmark Japan Russia/CIS Australia EuropeOther Korea Singapore Austria Finland Latin America Sweden Belgium France Middle East Switzerland Canada Germany Netherlands Taiwan Brazil India New Zealand UK/Ireland China (free call domestic) Italy Norway USA thermofisher.com/discreteanalysis 2017 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries. The information and technical specifications are subject to change without notice. Product availability may vary from country to country. Please contact your local sales representative for more information. D16080_ / 2017
Nitrogen/Protein Determination in Starch by Flash Combustion using Large Sample Weight as an Alternative to the Kjeldahl Method
Nitrogen/Protein Determination in Starch by Flash Combustion using Large Sample Weight as an Alternative to the Kjeldahl Method Liliana Krotz and Guido Giazzi Thermo Fisher Scientific, Milan, Italy Overview
More informationHigh-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine
High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring and in Urine Xiaolei Xie, Joe DiBussolo, Marta Kozak; Thermo Fisher Scientific, San Jose, CA Application Note 627 Key Words, norbuprenorphine,
More informationEnzymatic Analysis for Food and Feed
Enzymatic Analysis for Food and Feed Enzymatic tests are widely used as analytical tools for the analysis of food products such as fruit juices, wine or beer, dairy products, eggs and meat. Enzymatic test
More informationDetection and Quantification of Inorganic Arsenic in Fruit Juices by Capillary Ion Chromatography with Suppressed Conductivity Detection
Detection and Quantification of Inorganic Arsenic in Fruit Juices by Capillary Ion Chromatography with Suppressed Conductivity Detection Hua Yang, Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA
More informationAnalytical test kits. Glutamine Lactic acids Malic acids Pyruvic acid Sucrose Sulfite Urea
5 Analytical test kits Acetaldehyde Acetic acid Ammonia Arginine Ethanol Fructose Glucose Glutamine Lactic acids Malic acids Pyruvic acid Sucrose Sulfite Urea Principles & Features NZYTech test kits are
More informationCarl Fisher, Terri Christison, Hua Yang, Monika Verma, and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA
Fast Determination of Lactose and Lactulose in Dairy Products Using a 4 μm Particle Column and High-Performance Anion-Exchange Chromatography with Carl Fisher, Terri Christison, Hua Yang, Monika Verma,
More informationFT-Raman Surface Mapping of Remineralized Artificial Dental Caries
FT-Raman Surface Mapping of Remineralized Artificial Dental Caries I. Stangel, 1 R. Rubinovitz, 2 G.D. Arndt, 3 D. Byerly, 3 C. Theriot, 3 J.E. Kerr, 4 1 BioMat Sciences, Bethesda, MD; 2 Thermo Fisher
More informationDetermination of Carbohydrates in Kombucha Using HPAE-PAD
Determination of Carbohydrates in Kombucha Using HPAE-PAD Beibei Huang, Jingli Hu, and Jeffrey Rohrer Thermo Fisher Scientific, Sunnyvale, CA USA Application Note 1152 Key Words Glucose, Fructose, Sucrose,
More informationD-FRUCTOSE and D-GLUCOSE
www.megazyme.com DFRUCTOSE and DGLUCOSE (Liquid Stable Format) ASSAY PROCEDURE KFRGLQR 02/17 (1100 AutoAnalyser Assays of each per Kit) or (1100 Microplate Assays of each per Kit) Megazyme 2017 INTRODUCTION:
More informationThermo Scientific Dionex CarboPac MA1 Column
CHROMATOGRAPHY Thermo Scientific Dionex CarboPac MA Column Product Specifications HPLC columns for the analysis of weakly ionizable carbohydrates. Simple methods with pulsed amperometric detection Reduced
More informationHigh-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine
High-Throughput Quantitative LC-MS/MS Analysis of and 14 Benzodiazepines in Urine Bill Yu, Kristine Van Natta, Marta Kozak, Thermo Fisher Scientific, San Jose, CA Application Note 588 Key Words Opiates,
More informationDetermination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode
Deteration of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode Bruce Bailey, Marc Plante, David Thomas, Qi Zhang and Ian Acworth Thermo Fisher
More informationA Rapid UHPLC Method for the Analysis of Biogenic Amines and Metabolites in Microdialysis Samples
A Rapid UHPLC Method for the Analysis of Biogenic Aes and Metabolites in Microdialysis Samples Bruce Bailey and Ian Acworth; Thermo Fisher Scientific, Chelmsford, MA Overview Purpose: To develop an Ultra
More informationMercury Speciation Determinations in Asian Dietary Supplements
Mercury Speciation Determinations in Asian Dietary Supplements Terri Christison, Deepali Mohindra, Frank Hoefler, and Linda Lopez, Thermo Fisher Scientific, Sunnyvale, California, USA Overview Purpose:
More informationEnhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase
Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase Subhra Bhattacharya and Stephen C. Roemer Thermo Fisher Scientific Global Chemicals, Fair Lawn, NJ, USA AbstrAct Liquid
More informationThe Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis
The Investigation of Factors Contributing to Immunosuppressant Drugs Variability in LC-MS/MS Analysis Joseph Herman, Dayana Argoti, and Sarah Fair Thermo Fisher Scientific, Franklin, MA, USA Overview Purpose:
More informationBioPlex 2200 Infectious Disease Panels
BioPlex 2200 System BioPlex 2200 Infectious Disease Panels An Expanding Multiplexed Assay Menu Lyme HIV Ag-Ab MMV IgM Syphilis Total & RPR MMRV EBV HSV-1 & HSV-2 EBV IgM ToRC IgM ToRC Leading the way with
More informationGC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants
GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants Jeremy Matthews, 1 Alex Chen, 2 and Flavio Bedini 1 1 Thermo Fisher Scientific, Singapore; 2 Alpha Analytical Pte Ltd, Singapore Overview
More informationThermo Scientific ART Pipette Tips
LIQUID HANDLING Thermo Scientific ART Pipette Tips Now offering a broad selection of barrier, non-filter and specialty tips to fit virtually any pipette in your lab, Thermo Scientific ART pipette tips
More informationRapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection
Rapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection Bruce Bailey, Marc Plante, David Thomas, Qi Zhang and Ian Acworth Thermo Fisher Scientific, Chelmsford,
More informationMS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine
Application Note: 346 MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Gargi Choudhary and Diane Cho, Thermo Fisher Scientific, San Jose, CA Wayne Skinner and
More informationInternal Calibration System of Thermo Scientific Varioskan Flash with Improved Sensitivity, Accuracy and Dynamic Range
Internal Calibration System of Thermo Scientific Varioskan Flash with Improved Sensitivity, Accuracy and Dynamic Range Marika Raitio and Jorma Lampinen Thermo Fisher Scientific, Vantaa, Finland Key Words
More informationSolving One of Chromatography s Biggest Dilemmas Proper Sealing of Chromatography Autosampler Vials
Solving One of Chromatography s Biggest Dilemmas Proper Sealing of Chromatography Autosampler Vials D. Edwards 2, D. Lennartz 1, L.Shick 2 1 Thermo Fisher Scientific, Langerwehe, Germany 2 Thermo Fisher
More informationBio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c. VARIANT II TURBO Link System. Fully-Automated HbA 1c Testing
Bio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c VARIANT II TURBO Link System Fully-Automated HbA 1c Testing Bio-Rad Laboratories HEMOGLOBIN Testing VARIANT II TURBO Link System Efficient streamlined
More informationBio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c. VARIANT II TURBO Link. Fully-Automated HbA 1c Testing
Bio-Rad Laboratories HEMOGLOBIN Testing Bio-Rad A1c VARIANT II TURBO Link Fully-Automated HbA 1c Testing Bio-Rad Laboratories HEMOGLOBIN Testing VARIANT II TURBO Link Efficient streamlined process Powerful
More informationImproved Extraction and Analysis of Hexavalent Chromium from Soil and Water
Improved Extraction and Analysis of Hexavalent Chromium from Soil and Water Richard F. Jack, 1 Jinshui Che, 2 Lipika Basumallick, 1 and Jeffrey Rohrer 1 1 Thermo Fisher Scientific, Sunnyvale, CA, USA;
More informationComparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D
Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D Julie A. Horner 1, Marta Kozak 1, Subodh Nimkar 1, and August A. Specht 1 1 Thermo Fisher Scientific, San Jose,
More informationChemical compatibility of the Pall QPoint TM Docking Station - Tap Assembly with common surface disinfectants
Technical Report.78a Chemical compatibility of the Pall QPoint TM - Tap Assembly with common surface disinfectants QPoint - More than Filtration .0 Background The Pall QPoint Tap Water Filter Assembly
More informationManufacturer Report for Siemens Unassayed Chemistry Lot Exp 30 Jun 2018
Acetaminophen Enzymatic, colorimetric µg/ml.09 0..0.09 0..0 0. 0. 0. 0. 9.. 9.0 0.9.0..9.. Albumin Bromcresol Purple (BCP) g/dl.0 0.0..0 0.00.. 0.0.. 0.09..9 0.0..9 0.0..0 0.0..0 0.0. Alkaline Phosphatase
More informationEvaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites
Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites Valérie Thibert 1, Norbert Dirsch 2, Johannes Engl 2, Martin Knirsch 2 1 Thermo Fisher Scientific,
More informationOptimized for best performance in clinical chemistry testing
Optimized for best performance in clinical chemistry testing System Reagents for Indiko and Konelab clinical and specialty chemistry analyzers Complete system solutions Thermo Scientific system reagents
More informationCALIBRATION SERUM LEVEL 3 (CAL 3)
CALIBRATION SERUM LEVEL 3 (CAL 3) CAT. NO. CAL 2351 LOT NO. 907UE SIZE: 20 x 5ml EXPIRY: 2019-07-28 GTIN: 05055273200966 INTENDED USE For use as a Calibrator in clinical chemistry assays. RANDOX Calibration
More informationThe first and only fully-automated, multiplexed solution for Measles, Mumps, Rubella and Varicella-zoster virus antibody testing
Bio-Rad Laboratories BioPlex 2200 System BioPlex 2200 MMRV IgG Kit The first and only fully-automated, multiplexed solution for Measles, Mumps, Rubella and Varicella-zoster virus antibody testing Bio-Rad
More informationBioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS
Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS Jenny Chen, Hongxia Wang, Zhiqi Hao, Patrick Bennett, and Greg Kilby Thermo Fisher
More informationASSAYED URINE CONTROL - LEVEL 3 (URN ASY CONTROL 3)
SSAYED URINE CONTROL - LEVEL 3 (URN ASY CONTROL 3) CAT. NO. AU 2353 LOT NO. 797UC SIZE: 12 x 10 ml EXPIRY: 2019-03 INTENDED USE This product is intended for in vitro diagnostic use, in the quality control
More informationClinical Chemistry Reagents Brochure
Clinical Chemistry Reagents Brochure ekfdiagnostics.com Central Laboratory STANBIOChemistry from EKF Diagnostics Welcome to our Reagents Brochure EKF Diagnostics Stanbio Chemistry menu includes liquid-stable
More informationDetermination of Ethyl Sulfate Impurity in Indinavir Sulfate Drug Using Ion Chromatography
Application Note 8 Determination of Ethyl Sulfate Impurity in INTRODUCTION Indinavir sulfate is a specific and potent inhibitor of HIV- protease and is widely used in the treatment of AIDS. Indinavir sulfate
More informationImproving Food Process Control Using the
Improving Food Process Control Using the UPLC Amino Acid Analysis Solution Hillary B. Hewitson, Thomas E. Wheat, Diane M. Diehl INTRODUCTION Food products have different desirability and value based in
More informationEuropean Pharmacopoeia solutions
Reagena manufactures numerous Ph.Eur compliant solutions for use in quality control, production and identification. These products include buffers, stabilizers, identification reagents, controls, calibrators,
More information[ Care and Use Manual ]
MALDI Calibration Kit I. Introduction The MALDI Calibration Kit is a conveniently packaged selection of MALDI matrices and calibration standards (includes high-purity Neg Ion Mode Calibrant for accurate
More informationThermo Fisher Scientific, Sunnyvale, CA, USA; 2 Thermo Fisher Scientific, San Jose, CA, USA
An Ultra High Resolution Glycan Column for Isomeric Separation and the Structural Identification of Labeled N-Glycans from Proteins Including Antibodies Udayanath Aich, 1 Julian Saba, 2 Rosa Viner, 2 Shanhua
More informationProviding a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis
Providing a Universal, ne-step Alternative to Liquid-Liquid Extraction in Bioanalysis Jessalynn P. Wheaton, Erin E. Chambers, and Kenneth J. Fountain APPLICATIN BENEFITS n Simple, one-step sample preparation
More informationCALIBRATION SERUM LEVEL 3 (CAL 3)
CALIBRATION SERUM LEVEL 3 (CAL 3) CAT. NO. CAL 2351 LOT NO. 709UE SIZE: 20 x 5ml EXP: 2016-12 INTENDED USE For use as a Calibrator in clinical chemistry assays. RANDOX Calibration Sera are based on lyophilised
More informationDetermination of Inorganic Ions and Organic Acids in Non-Alcoholic Carbonated Beverages
Application Note Determination of Inorganic Ions and Organic Acids in Non-Alcoholic Carbonated Beverages INTRODUCTION The determination of inorganic anions and cations and organic acids in non-alcoholic
More informationThermo Scientific System Reagents Excellence in Clinical Chemistry
Thermo Scientific System Reagents Excellence in Clinical Chemistry Part of Thermo Fisher Scientific Covering over 150 CE marked products, Thermo Scientific system reagents are specifically developed and
More informationExcellence and confidence
Thermo Scientific System Reagents Fully supported and guaranteed, CE marked system solutions Streamlined supply and support Maximum stability and reduced waste Standardised performance in External Quality
More informationCardiac Assessment Controls
Bio-Rad Laboratories CARDIAC ASSESSMENT CONTROLS Cardiac Assessment Controls Value Assigned for Clinical Laboratory and Point of Care Test Systems Solving the Challenges of Troponin I Testing for the Central
More informationSafety and added value, guaranteed
Food and Feed Analysis Safety and added value, guaranteed Costa Brava 30, 08030 Barcelona (España) Tel. +34 93 311 00 00 foodquality@biosystems.es www.biosystems.es Modern society demands safe foods that
More informationIncreasing Extraction Efficiency of Wet Samples Using a Novel New Polymer During Accelerated Solvent Extraction
Increasing Extraction Efficiency of Wet Samples Using a Novel New Polymer During Accelerated Solvent Extraction SM Rahmat Ullah, Kannan Srinivasan, Chris Pohl, Pranathi Perati and Alexander Zhang Thermo
More informationResults you can trust
PRODUCT I NF OR MAT ION pharmdx Results you can trust The first and only FDA-approved PD-L1 test to assess the magnitude of treatment effect on progression-free survival in melanoma patients from OPDIVO
More informationDayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA
The Utilization of Novel Platform in a LC-MS/MS Workflow for the Analysis of Vitamin D, Testosterone, Immunosuppressants, Chemotherapeutics and Cortisol Dayana Argoti, Kerry Hassell, Sarah J. Fair, and
More informationBio-Rad Laboratories. Hemoglobin Testing. VARIANT II Hemoglobin Testing System For HbA 1c
Bio-Rad Laboratories Hemoglobin Testing VARIANT II Hemoglobin Testing System For HbA 1c Bio-Rad CDM System CDM 5.1 VII Instrument Patient Report V2_A1c_NU Patient Data Sample ID: AD Patient ID: Name: Physician:
More informationMeasuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA
Measuring Phytosterols in Health Supplements by LC/MS Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA Overview Purpose: Develop a method for the extraction of phytosterols
More informationInfectious Disease Testing. ULTRA Product Line. Safety is not a Matter of Chance
Infectious Disease Testing ULTRA Product Line Safety is not a Matter of Chance ULTRA Product Line The best answer for HBV, HCV and HIV screening: a global automated solution for safe results. Monolisa
More informationQuantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation
Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation Valérie Thibert, Bénédicte Duretz Thermo Fisher Scientific, Courtaboeuf,
More informationApplicationNOTE EXACT MASS MEASUREMENT OF ACTIVE COMPONENTS OF TRADITIONAL HERBAL MEDICINES BY ORTHOGONAL ACCELERATION TIME-OF-FLIGHT.
Objective The aim of the study presented is to determine the presence of target Gingkolides in Gingko biloba leaf extract. The data presented shows Gingkolides determined to be present in the extract analyzed.
More informationClinical Chemisty Reagents Brochure. ekfdiagnostics.com STANBIOChemistry from EKF Diagnostics. Central Laboratory
Clinical Chemisty Reagents Brochure ekfdiagnostics.com STANBIOChemistry from EKF Diagnostics Central Laboratory Welcome to our Reagents Brochure EKF Diagnostics Stanbio Chemistry menu includes liquid-stable
More informationFast UHPLC Methods for Analysis of Amino Acids
Fast UHPLC Methods for Analysis of Ao Acids Qi Zhang, Bruce Bailey, Marc Plante, David Thomas, and Ian Acworth Thermo Fisher Scientific, Chelmsford, MA, USA Overview Purpose: Methods that offer both rapid
More informationCALIBRATION SERUM - LEVEL 2 (CAL 2)
CAT. NO. CAL 2350 LOT NO. 1242UN SIZE: 20 x 5ml EXPIRY: 2020-02-28 GTIN: 05055273200959 INTENDED USE For use as a Calibrator in clinical chemistry assays. RANDOX Calibration Sera are based on lyophilised
More informationAPPLICATIONS TN Determination of Sugars in Animal Feed using HPLC-ELSD
Determination of Sugars in Animal Feed using HPLC-ELSD Laura Snow, Zeshan Aqeel, Allen Misa and Scott Krepich Phenomenex, Inc., Madrid Ave., Torrance, CA 9050 USA Laura Snow Scientist- Phenologix Outside
More informationASSAYED URINE CONTROL - LEVEL 2 (URN ASY CONTROL 2)
ASSAYED URINE CONTROL - LEVEL 2 (URN ASY CONTROL 2) CAT. NO. AU 2352 LOT NO. 718UC SIZE: 12 x 10ml EXPIRY: 2017-10 INTENDED USE This product is intended for in vitro diagnostic use in the quality control
More informationshort catalogue diasys diagnostic systems clinical chemistry immunoturbidimetric tests calibrators standards controls supplementary reagents
::010 ::011 ::012 ::013 ::014 ::015 ::016 ::017 ::018 short catalogue 11 ::026 ::027 ::028 ::029 ::030 ::031 ::032 ::036 ::037 ::038 ::039 ::043 ::044 ::045 clinical chemistry ::048 ::049 immunoturbidimetric
More informationThe Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection
Application Note 9 The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection INTRODUCTION The accurate measurement of the amount of sugar in final molasses
More informationThird Party Controls for Your Dade Behring Systems
Bio-Rad Laboratories Q U A L I T Y C O N T R O L Third Party Controls for Your Dade Behring Systems The Complete QC Solution from Bio-Rad Laboratories Bio-Rad has the control you need for your Dade Behring
More informationWELCOME. NZYTech is an ISO 9001:2008 certified company. We are continuosly improving the excellence of our operational and quality systems.
2017 ASSAY KITS WELCME At NZYTech we work passionately to achieve our goals. ur mission is to provide the scientific and industrial communities with a wide range of first class high quality products &
More informationDynamic Analysis of HIV-Human Protein-Protein Interactions During Infection
Dynamic Analysis of HIV-Human Protein-Protein Interactions During Infection Jeffrey Johnson, 1 Shannon Eliuk, 2 Amnon Golan, 1 Tasha Johnson, 1 Vlad Zabrouskov, 2 Nevan Krogan 1 1 UCSF, San Francisco,
More informationFOOD TESTING RAPID'L.Mono Chromogenic Media. Detect Listeria Species in 24 Hours
FOOD TESTING RAPID'L.Mono Chromogenic Media * Fast results Easy identification by colony color Cost-effective detection Choice of plates or bottled media Simple protocol Independent test validation Complete
More informationA New Era in SFC Column Technology
B TM A ew Era in SFC Column Technology Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level
More informationCardiac Assessment Controls A critical element of reliable cardiac testing
Cardiac Assessment Controls Cardiac Assessment Controls A critical element of reliable cardiac testing Choose the products best suited for your cardiac assessment needs Each year, 17.7 million people on
More informationTGX and TGX Stain-Free FastCast Acrylamide Kits
Electrophoresis TGX and TGX Stain-Free FastCast Acrylamide Kits The newest frontier for handcast gels It s Time to Expect More from Handcast Gels! FastCast kits provide unparalleled convenience and performance.
More informationAnnex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005
Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-14285-01-00 according to DIN EN ISO/IEC 17025: Period of validity: 03.02.2017 to 14.09.2021 Holder of certificate: ADM WILD
More informationInfectious Disease Testing. UriSelect 4 Medium. Direct Identification Visibly Reliable
Infectious Disease Testing Urielect 4 Medium Direct Identification Visibly Reliable Urielect 4 Non selective chromogenic medium for the isolation, differentiation and enumeration of urinary tract infections
More informationThermo Scientific LipidSearch Software for Lipidomics Workflows. Automated Identification and Relative. Quantitation of Lipids by LC/MS
Thermo Scientific LipidSearch Software for Lipidomics Workflows Automated Identification and Relative of Lipids by LC/MS The promise of lipidomics Lipidomics is a new field of study crucial for understanding
More informationPosterREPRINT INTRODUCTION. 2-D PAGE of Mouse Liver Samples. 2-D PAGE of E.coli Samples. Digestion / Cleanup. EXPERIMENTAL 1-D PAGE of BSA Samples
INTRODUCTION Identification and characterization of low abundance proteins separated by 2D gel electrophoresis is complicated by two important factors; the use of suitable staining techniques for the visualization
More informationCLINICAL CHEMISTRY REAGENTS. Product Profile
Product Profile Why Clinical Chemistry Reagents? Quantitative determination of specific analytes associated with various types of disease. Diagnosis Identifying a disease already present Prognosis Forecasting
More informationReflectometry Reflectoquant
Reflectometry Reflectoquant General information 58 RQflex 10 61 RQflex 10 plus 61 Test kits 62 57 Reflectometric Measurements Reflectoquant Easy in-process monitoring The simplest possible handling combined
More informationETB Data. there was. compared
AETA 2009 Survey Report Introduction Included in this report are survey data collected from the member embryo transfer business ss (ETB s) of the American Embryo Transfer Association for 2009. This report
More informationDetermination of Carbohydrates in Beverages and Milk Products by HPAE-PAD and Capillary HPAE-PAD
Determination of Carbohydrates in Beverages and Milk Products by HPAE-PAD and Capillary HPAE-PAD Terri Christison, Monika Verma, Aaron Kettle, Carl Fisher, Linda Lopez; Thermo Fisher Scientific, Sunnyvale,
More informationDetermination of Benzoate in Liquid Food Products by Reagent-Free Ion Chromatography
Application Note 65 Determination of Benzoate in Liquid Food Products by Reagent-Free Ion Chromatography INTRODUCTION Preservatives are commonly added to many food products, such as soda, fruit juice,
More informationUse of a Tandem Mass Spectrometry Research Method for the Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots
Use of a Tandem Mass Spectrometry Research Method for the Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots Xiaolei Xie and Marta Kozak Thermo Fisher Scientific, San Jose, CA, USA Application
More informationSialic Acid Determination in Glycoproteins: Comparison of Two Liquid Chromatography Methods. Experimental. Introduction. Method 1.
Sialic Acid Determination in Glycoproteins: Comparison of Two Liquid Chromatography Methods Deanne Hurum and Jeffrey Rohrer, Thermo Fisher Scientific, Sunnyvale, CA, USA Introduction Sialic acids are critical
More informationHRM Series PCB Power Relays
Features: SPCO contacts. Sealed to allow washing after flow soldering. Specifications: Coil Data: Nominal Voltage Nominal Power consumption : 3V dc to 24V dc. : 540mW to 720mW. Contact Data: Contact Arrangement
More informationPRODUCT INFORMATION. New Reagents for Dako CoverStainer. Choose the H&E staining intensity you want.
PRODUCT INFORMATION Primary Staining Dako CoverStainer Reagents New Reagents for Dako CoverStainer. Choose the H&E staining intensity you want. New flexible staining intensities to fit y Dako H&E Staining
More informationImmunohematology. IH-QC Modular System. Select. Combine. Control.
Immunohematology IH-QC Modular System Select. Combine. Control. IH-QC Modular System Select. Combine. Control. Transfusion guidelines recommend regular checking of test materials, test methods, local working
More informationEnhancing Sequence Coverage in Proteomics Studies by Using a Combination of Proteolytic Enzymes
Enhancing Sequence Coverage in Proteomics Studies by Using a Combination of Proteolytic Enzymes Dominic Baeumlisberger 2, Christopher Kurz 3, Tabiwang N. Arrey, Marion Rohmer 2, Carola Schiller 3, Thomas
More informationHeart Health Exploring the OTC options
Heart Health Exploring the OTC options (186 pages) Definitions & methodology Executive summary (26 pages) Overview Cardiovascular diseases are the world s biggest killer What are cardiovascular diseases?
More informationLC-MS/MS Method for the Determination of Tenofovir from Plasma
LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract
More informationHUMAN ASSAYED MULTI-SERA - LEVEL 3 (HUM ASY CONTROL 3)
0086 HUMAN ASSAYED MULTI-SERA - LEVEL 3 (HUM ASY CONTROL 3) CAT. NO. HE1532 / HS2611 LOT NO. 789UE SIZE: 20 x 5ml / 5 x 5ml EXP: 2019-05 INTENDED USE This product is intended for in vitro diagnostic use
More informationLC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine
LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine J. Jones, S. Westwood, T. Liddicoat, L. Pereira, T. Edge Thermo Fisher Scientific, Manor Park, Runcorn, UK Overview Purpose:
More informationHER2 CISH pharmdx TM Kit Interpretation Guide Breast Cancer
P A T H O L O G Y HER2 CISH pharmdx TM Kit Interpretation Guide Breast Cancer FROM CERTAINTY COMES TRUST For in vitro diagnostic use HER2 CISH pharmdx Kit HER2 CISH pharmdx Kit is intended for dual-color
More informationFOURIER STUDY GREYLOCK PRESS: CTS PRODUCT SAMPLE - FOURIER YES. Did the study achieve its main objective?
FOURIER STUDY Did the study achieve its main objective? 2 15% 1 5% 9.8% YES FOURIER compared Repatha with placebo in patients who were taking a statin and had hardening or narrowing of the arteries and
More informationslge112 Molecular Allergology Product Characteristics ImmunoCAP ISAC slge 112
slge112 Molecular Allergology Product Characteristics ImmunoCAP ISAC slge 112 IMMUNOCAP ISAC 112 Contents Intended Use 1 Principle of test procedure 1 Clinical utility 1 Sample information 2 Measuring
More informationBio-Rad Laboratories. Cardiac Assessment Controls. Value Assigned for Clinical Laboratory and Point of Care Test Systems
Bio-Rad Laboratories Cardiac Assessment Controls Cardiac Assessment Controls Value Assigned for Clinical Laboratory and Point of Care Test Systems Solving the Challenges of Troponin I Testing for the Central
More informationRespiration. Organisms can be classified based on how they obtain energy: Autotrophs
Respiration rganisms can be classified based on how they obtain energy: Autotrophs Able to produce their own organic molecules through photosynthesis Heterotrophs Live on organic compounds produced by
More informationWESTERN EUROPE PREVALENCE AND INCIDENCE OF PERIPHERAL ARTERY DISEASE AND CRITICAL LIMB ISCHEMIA 2017
WESTERN EUROPE PREVALENCE AND INCIDENCE OF PERIPHERAL ARTERY DISEASE AND CRITICAL LIMB ISCHEMIA 2017 Mary L. Yost 404-520-6652 , LLC 23 Ridge Rd. Beaufort, SC 20097 Copyright Pending 2017 All rights reserved,
More informationHER2 FISH pharmdx TM Interpretation Guide - Breast Cancer
P A T H O L O G Y HER2 FISH pharmdx TM Interpretation Guide - Breast Cancer For In Vitro Diagnostic Use FDA approved as an aid in the assessment of patients for whom Herceptin TM (trastuzumab) treatment
More informationIntegrated Targeted Quantitation Method for Insulin and its Therapeutic Analogs
Integrated Targeted Quantitation Method for Insulin and its Therapeutic Analogs Eric Niederkofler, 1 Dobrin Nedelkov, 1 Urban Kiernan, 1 David Phillips, 1 Kemmons Tubbs, 1 Scott Peterman, 2 Bryan Krastins,
More informationWater. Nutrition Facts Serving Size 20 fl oz (591 ml) Servings Per Container 1. Amount Per Serving Calories 0 Calories from Fat 0
Water Serving Size 20 fl oz (591 ml) Servings Per Container 1 Calories 0 Calories from Fat 0 Sodium 0mg 0% Total Carbohydrate 0g 0% Sugars 0g Not a significant source of other nutrients. Ingredients: PURIFIED
More informationHUMAN ASSAYED MULTI-SERA - LEVEL 2 (HUM ASY CONTROL 2)
0120 HUMAN ASSAYED MULTI-SERA - LEVEL 2 (HUM ASY CONTROL 2) CAT. NO. HN1530 / HS2611 LOT NO. 995UN SIZE: 20 x 5ml / 5 x 5ml EXP: 2018-12 INTENDED USE This product is intended for in vitro diagnostic use,
More informationHUMAN ASSAYED MULTI-SERA - LEVEL 2 (HUM ASY CONTROL 2)
0843 HUMAN ASSAYED MULTI-SERA - LEVEL 2 (HUM ASY CONTROL 2) CAT. NO. HN1530 / HS2611 LOT NO. 899UN SIZE: 20 x 5ml / 5 x 5ml EXPIRY: 2018-02 INTENDED USE This product is intended for in vitro diagnostic
More information