Scientific Programme 40 glorious years of AMPI
|
|
- Jeffrey Doyle
- 5 years ago
- Views:
Transcription
1 Scientific Programme 40 glorious years of AMPI Annual Conference of Association of Medical Physicists of India (Northern Chapter) February 20-21, 2016 Exploring Diverse Applications of Medical Physics in Cancer Management Saturday February 20, 2016 Venue: KN Udupa Auditorium, IMS, BHU, Varanasi Day-1 (Saturday) February 20, AM Onwards Registration 8.00 AM 9:00 AM Breakfast Session AM to 9:45 AM Dr NC Singhal Oration Chairpersons: Dr Arun Chougule and Dr Atul Tyagi Evolution of Radiotherapy at MOH Dr Kamlesh Passi Session-2 9:45 AM to AM Advances in Radiation Oncology Chairpersons : Dr AK Shukla and Dr RNL Srivastva 9: I-1 Advancements in Regulation in Application of Radiation in Medicine Dr AU Sonawane 10:00-10:15 I-2 Cyberknife : How has it changed the radiotherapy practice? Dr S Hukku 10:15 10:30 I-3 Pitfall in Stereotactic Ablative Body Radiotherapy (SABR) Dr. Dayananda Sharma Session-3 10:45 AM to 11:45 AM Image based Radiotherapy Chairpersons: Dr P Chaurasia and Dr Sai Vardharajan 10:45-11:00 I-4 Early experience with 3D Ultrasound based Image Guided Radiotherapy. Dr Gautam Sharan 11:00-11:15 I-5 Relevance of brachytherapy in era of IMRT/ IGRT in head and neck cancers Dr Sushmita Ghoshal 11:15 11:30 I-6 Image based radiotherapy, where we stand? Dr R Chary 11:45-12:00 Tea PM to 1.00 PM Inauguration Session PM to 1.30 PM Dosimetry Chairpersons: Dr NK Painuly and Dr AK Srivastva
2 1:00 1:10 O-1 Validation of simultaneous treatment of multiple targets in thorax region planned with mono isocenter using three dimensional conformal radiotherapy(3dcrt) A dosimetric study using an in-house made thorax phantom Challapalli Srinivas 1:10 1:20 O-2 Dosimetric characterization of commercial OSL nanodot for Diagnostic energy range use - A care should be taken for use Gourav Kumar Jain 1:20 1:30 O-3 Dosimetric evaluation of synthetic single crystal diamond detector. Prashant Kumar Shinde 1.30 PM to 2.30 PM Lunch Session PM to 3.30 PM Quantitative imaging going beyond displaying medical images Chairpersons : Dr VK Dangwal and Dr Rajesh Singh 2:30 2:45 I-7 Reconstruction techniques in Nuclear Medicine Imaging Dr S Kheruka 2:45 3:00 I-8 Quantification an important tool in radiotherapy planning Dr Pankaj Tandon 3:00 3:15 I-9 Particle radiotherapy: An Emerging Technology for Treatment of Cancer Dr AK Rath 3:15 3:25 O-4 Optimization of input parameters of Supra-threshold Stochastic Resonance image processing algorithm for the detection of Abdomino-Pelvic tumors on PET/CT scan Kartik Saroha Session PM to 4.30 PM Patient positioning and Immobilization in IGRT/IMRT Chairpersons: Dr Devesh Gupta and Mr N Balasubramanian 3:30 3:45 I-10 Patient Positioning And Immobilization In Static And Dynamic Adaptive Radiotherapy: An Integral Part Of IGRT Dr Arun S Oinam 3:45 4:00 I-11 Non-radiographic Methods of IGRT Dr Manoj Samewal 4:00 4:15 T-1 What's new in radiotherapy from Teambest. Muralidharan AN 4.15 PM to 4.30 PM Tea Session-7 4:30 PM to 5.30 PM Treatment planning and execution Chairpersons : Dr K Adhikari and Mr Suraj Mishra 4:30 4:45 I-12 Past, present and future of VMAT technique in different sites: Breast, Head and Neck, Brain and Craniospinal irradiation for medduloblastoma and PNET treatment Mr Biplab Sarkar 4:45 5:00 I-13 Commemorating Forty Years of AMPI Dr Arun Chougule 5:00 5:15 I-14 Heterogeneities and treatment planning system dose calculation Dr Anuj Tyagi
3 5:15 5: Impact of systematic errors on DVH parameters of different oar and target volumes in intracavitary brachytherapy (ICBT) Ankur Mourya 5.30 PM to 6.30 PM Session-8 Panel Discussion: will Co-60 replace the Ir-192 source for Brachytherapy Moderator : Dr V Subramani Clinician View: For the motion : Against The motion : Dr Vikas Kumar Mr Saji Oomen Mr Gobinda Pal 6.30 PM General Body Meeting (GBM) AMPI-NC 7.00 PM onwards Dinner, Venue Hotel Madhuvan Palace, Near DLW Day-2 (Sunday), February 21, AM to 9.00 AM Breakfast Session AM to AM Quality control: Imaging and therapy Chairpersons : Dr SC Bansal and Mr MPS Mann 9:00 9:10 O-6 Total Skin electron Beam therapy (TSET): Commissioning and first application at PGIMER, Chandigarh Gaurav Trivedi 9:10 9:20 O-7 Quality assurance of dynamic MLC for volumetric modulated arc therapy using EPIQA Shaheen Parveen 9:20 9:35 I-16 Monte Carlo based Dose Calculations in Clinical Treatment Planning System Dr T Ganesh 9:35 9: 50 I-15 Basic quality control in diagnostic radiology Mr.Erik Wikstrom Session AM to AM CMPI Teaching Session Chairpersons: Dr C Srinivas and Dr Tiwari 10:00 10:15 I-17 Overview of Image Guided Radiotherapy Dr KJ Maria Das 10:15 10:30 I-18 Clinical practice of IGRT with correction strategy Dr T Ganesh 10:30 10:45 I-19 Quality assurance of Image guided Radiotherapy Mr. Ritu Raj AM to AM Tea Session AM to PM Free Paper Session Chairpersons : Dr Vivek Kumar and Mr Bikramjit Singh 11:15-11:30 I-20 Newer Trends in Bio-Electrical Activities Dr. D V Rai
4 11:30 11:40 O-8 Finding optimum beam arrangement in intensity modulated radiotherapy planning for pituitary adenoma in terms of TCP and NTCP Richa Sharma 11:40 11:50 O-9 Teaching the programming concepts to Nuclear Medicine using scratch 2.0 programming language Anil Kumar Pandey 11:50 12:00 O-10 Biomedical application of resonant X-rays on high Z nanomaterials L.Natarajan 12:00 12:10 O-11 Requirement analysis for the Interactive Multimedia educational package on Filtered Back Projection Technique Umesh yadav Session AM to 2.00 PM Mohan Dai Oswal Best Paper Session Chairpersons :Dr Rajesh Vashistha and Dr Neeraj Sharma 12:30 12:40 BP-1 Dosimetric evaluation of complex/irregular fields generated by Eclipse Treatment planning system for Bhabhatron-II telecobalt unit. Athiyaman 12:40 12:50 BP-2 Composition analysis of Ex-Vivo Coronary Atherosclerotic Plaque samples by Dual Energy CT: For non invasive detection of complicated plaque Avinav Bharati 12:50 1:00 BP-3 RPM gating IMRT with indigenously designed Non-monotonous Segmented MLC leaf sequences: A Clinically feasible Safe gated IMRT Gaganpreet Singh 1:00 1:10 BP-4 Establishing inherent uncertainty in the shifts determined by volumetric imaging Giri U K 1:10 1:20 BP-5 Large Field Splitting for Dynamic IMRT treatments reducing MLC interplay effect and Total MU delivered. Rose Kamal 1:20-1:30 BP-6 Frameless stereotaxy: Initial experience at a tertiary care centre using dual imaging environment using six dimensional couch movements. Satheesh A 1:30 1:40 BP-7 Determination of optimal PTV margins Shefali Pahwa 1:40-1:50 BP-8 Investigation of dose prediction accuracy of Pencil beam convolution algorithm in a inhomogeneous phantom VP Pandey Procedure for Selection of Mohan Dai Oswal Best Paper Five Judges will select best paper award as per following criteria. Marks Quality of subject matter 15 Quality of slides 05 Quality of presentation 10 Time limit 05 Question and answer 15 Total 50 Qualifying marks PM to 2.30 PM Valedictory Function 2.30 PM Lunch
5 Best Poster Presentation Instruction for poster presentation: Display time: From 20 th Feb,2016 before 11:00 AM to 21 st Feb,2016 before 12:00 AM Size of the poster: 30 Inches (Height) x 40 Inches (Width) Marks Quality of subject matter 15 Quality of Poster 05 Quality of Poster composing 15 Question and answer 15 Total 50 Qualifying marks 30 List of Posters All the Posters would be Evaluated for Best Poster Award P-1 Effects of variable tube voltages & slice thicknesses of CT scanner on CT calibration curve Ritesh Mhatre P-2 Segmentation of soft tissue structure in a CT slice corresponding to Liver. Deepak Aheer P-3 Measurement of effective attenuation coefficient a new compensator alloy KAUSHIK S P-4 Estimates of radiation doses to extremity, eye lens and thyroid during cardiac catheterization V. Chaturvedi P-5 Dosimetric Comparison of Volumetric Modulated Arc Therapy (VMAT), DMLC (Dynamic IMRT), and 3DCRT in Left breast Cancer after Breast Conserving Surgery receiving Left Breast Irradiation Bauskar Pratibha P-6 A treatment planning ANALYSIS FOR comparing 3D Conformal radiotherapy modulation and fixed field IMRT for cervix uteri radiotherapy with cisplatin K.N.SRIKANTH P-7 A Study on the Effect of Orientation of the Stereotactic Field Detector in Small Field Dosimetry Bhagat Chand P-8 Monte Carlo simulation of Varian Medical Linear Accelerator for different electron beam energies Bhumika Handa P-9 Radiation dose audit for patients undergoing digital radiography examinations in Uttarakhand (India) V. Prasad P-10 Impact of Catheter Reconstruction error on dose distribution in High Dose Rate Intracavitary Brachytherapy and evaluation of OAR doses Deepak Thaper P-11 Automatic Registration Using Intensity Based Similarity Measure Radhika Jain P-12 Patient Dose with Quality Image under Diagnostic Reference levels Suresh Kumar Akula P-13 New Imaging Technologies for Screening, Staging & Management of Cancer UMESH YADAV P-14 Study of effect of different CT scanning protocols on HU variation and their impact on TPS Calculations
6 Mamta Mahur P-15 A measurement of radiation output from X- ray Tubes: AIIMS Experience R. Karan P-16 Analysis of daily quality assurance tests for Tomotherapy and two Varian linear accelerators Three months review. Pratishtha Kushwaha P-17 Self assessment & detection of breast cancer Priyanka Singh P-18 Conventional patient specific IMRT QA and 3DVH verification of Dose Distribution for Helical Tomotherapy Prabhat Krishna Sharma P-19 Radiation induced cancer risk estimation for contralaterl breast in 3 D conformal treatments of post mastectomy cancer patients based on OED Hemalatha A Thanks
EORTC Member Facility Questionnaire
Page 1 of 9 EORTC Member Facility Questionnaire I. Administrative Data Name of person submitting this questionnaire Email address Function Phone Institution Address City Post code Country EORTC No Enter
More informationTHE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS
THE TRANSITION FROM 2D TO 3D AND TO IMRT - RATIONALE AND CRITICAL ELEMENTS ICTP SCHOOL ON MEDICAL PHYSICS FOR RADIATION THERAPY DOSIMETRY AND TREATMENT PLANNING FOR BASIC AND ADVANCED APPLICATIONS March
More informationLeila E. A. Nichol Royal Surrey County Hospital
2 nd UK and Ireland Dosimetry Check User Meeting Symposium Clatterbridge Cancer Centre, 24 th October 2012 Leila E. A. Nichol Royal Surrey County Hospital Leila.Nichol@nhs.net *My experience with Dosimetry
More informationCURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT
CURRICULUM OUTLINE FOR TRANSITIONING FROM 2-D RT TO 3-D CRT AND IMRT Purpose The purpose of this curriculum outline is to provide a framework for multidisciplinary training for radiation oncologists, medical
More informationGuideline & Reports 医学物理学会教育委員会資料
Guideline & Reports 医学物理学会教育委員会資料 2017/11 更新 report title year keyword 1 keyword 2 AAPM TG211 Classification and evaluation strategies of auto-segmentation approaches for PET 2017 PET autosegmentation
More informationVerification of Advanced Radiotherapy Techniques
Verification of Advanced Radiotherapy Techniques Catharine Clark, PhD Principal Research Scientist Radiation Dosimetry group and Consultant Clinical Scientist Royal Surrey County Hospital 2 nd December
More informationMedical Dosimetry Graduate Certificate Program IU Graduate School & The Department of Radiation Oncology IU Simon Cancer Center
Medical Dosimetry Graduate Certificate Program IU Graduate School & The Department of Radiation Oncology IU Simon Cancer Center All students accepted into the Medical Dosimetry Graduate Certificate Program
More informationTherapeutic Medical Physics. Stephen J. Amadon Jr., Ph.D., DABR
Therapeutic Medical Physics Stephen J. Amadon Jr., Ph.D., DABR Outline 1. Why physicists are needed in medicine 2. Branches of medical physics 3. Physics in Radiation Oncology 4. Treatment types and Treatment
More informationWHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY
doi:10.1016/j.ijrobp.2009.03.029 Int. J. Radiation Oncology Biol. Phys., Vol. 75, No. 1, pp. 253 259, 2009 Copyright Ó 2009 Elsevier Inc. Printed in the USA. All rights reserved 0360-3016/09/$ see front
More informationRADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident
Resident s Name: RADIATION ONCOLOGY RESIDENCY PROGRAM Competency Evaluation of Resident Rotation: PHYS 703: Clinical Rotation 2 Inclusive dates of rotation: Feb. 26, 2016 Aug. 25, 2016 Director or Associate
More informationEvaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases
Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases CASE STUDY Institution: Odette Cancer Centre Location: Sunnybrook
More informationTreatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI)
Treatment Planning Evaluation of Volumetric Modulated Arc Therapy (VMAT) for Craniospinal Irradiation (CSI) Tagreed AL-ALAWI Medical Physicist King Abdullah Medical City- Jeddah Aim 1. Simplify and standardize
More informationImplementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy
Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy Implementation of radiosurgery and SBRT requires a fundamentally sound approach Errors don t blur out
More informationAssessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom
Assessing Heterogeneity Correction Algorithms Using the Radiological Physics Center Anthropomorphic Thorax Phantom David Followill, Ph.D. Associate Director Radiological Physics Center RPC History Lesson
More informationQuality Assurance of TPS: comparison of dose calculation for stereotactic patients in Eclipse and iplan RT Dose
Petrovic B Comparison of dose calculation algorithms for stereotaxy Quality Assurance of TPS: comparison of dose calculation for stereotactic patients in and RT Dose Borislava Petrovic 1, Aleksandra Grządziel
More informationTechnical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.
Technical Study Stereotactic Radiosurgery with Elekta Versa HD and Monaco Accuracy of a single isocenter, multiple brain metastases VMAT plan delivered to a pseudo-patient dosimetric gel phantom Institution
More informationReena Phurailatpam. Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery
Intensity Modulated Radiation Therapy of Medulloblastoma using Helical TomoTherapy: Initial Experience from planning to delivery Reena Phurailatpam Tejpal Gupta, Rakesh Jalali, Zubin Master, Bhooshan Zade,
More informationIROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015
IROC Liver Phantom Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015 The study groups are requests that each institution keep the phantom for no more than 2 weeks. During
More informationI. Equipments for external beam radiotherapy
I. Equipments for external beam radiotherapy 5 linear accelerators (LINACs): Varian TrueBeam 6, 10 & 18 MV photons, 6-18 MeV electrons, image-guided (IGRT) and intensity modulated radiotherapy (IMRT),
More informationAAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction
AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction Parham Alaei, Ph.D. Department of Radiation Oncology University of Minnesota NCCAAPM Fall
More informationPGY-1. Resident Review Session Schedule
1. August Simulation & Treatment 1.1. Sim Setup 1.2. Sim Techniques 1.3. 4DCT 1.4. Breath Hold / Gating 1.5. Treatment Setup 1.6. Treatment Delivery 1.7. Filming 1.7.1. Port film 1.7.2. kv 1.7.3. CBCT
More informationThe Radixact System Experience at Miami Cancer Institute. Tino Romaguera, D.Sc. Senior Physicist
The Radixact System Experience at Miami Cancer Institute Tino Romaguera, D.Sc. Senior Physicist Disclosure An honorarium is provided by Accuray for this presentation The views expressed in this presentation
More informationSBRT fundamentals. Outline 8/2/2012. Stereotactic Body Radiation Therapy Quality Assurance Educational Session
Stereotactic Body Radiation Therapy Quality Assurance Educational Session J Perks PhD, UC Davis Medical Center, Sacramento CA SBRT fundamentals Extra-cranial treatments Single or small number (2-5) of
More informationAccuracy Requirements and Uncertainty Considerations in Radiation Therapy
Departments of Oncology and Medical Biophysics Accuracy Requirements and Uncertainty Considerations in Radiation Therapy Introduction and Overview 6 August 2013 Jacob (Jake) Van Dyk Conformality 18 16
More informationMany vendors are beginning to allow couch motion during radiation delivery.
Dynamic Couch Motion Many vendors are beginning to allow couch motion during radiation delivery. Varian developer mode allows institutions to perform research using these types of treatments. Tomotherapy
More informationAdvances in external beam radiotherapy
International Conference on Modern Radiotherapy: Advances and Challenges in Radiation Protection of Patients Advances in external beam radiotherapy New techniques, new benefits and new risks Michael Brada
More informationQuality assurance and credentialing requirements for sites using inverse planned IMRT Techniques
TROG 08.03 RAVES Quality assurance and credentialing requirements for sites using inverse planned IMRT Techniques Introduction Commissioning and quality assurance of planning systems and treatment delivery
More informationCredentialing for the Use of IGRT in Clinical Trials
Credentialing for the Use of IGRT in Clinical Trials James M. Galvin, DSc Thomas Jefferson University Hospital Jefferson Medical College Philadelphia, PA and The Radiation Therapy Oncology Group RADIATION
More informationDefining Target Volumes and Organs at Risk: a common language
Defining Target Volumes and Organs at Risk: a common language Eduardo Rosenblatt Section Head Applied Radiation Biology and Radiotherapy (ARBR) Section Division of Human Health IAEA Objective: To introduce
More informationOriginal Article. Teyyiba Kanwal, Muhammad Khalid, Syed Ijaz Hussain Shah, Khawar Nadeem
Original Article Treatment Planning Evaluation of Sliding Window and Multiple Static Segments Technique in Intensity Modulated Radiotherapy for Different Beam Directions Teyyiba Kanwal, Muhammad Khalid,
More informationNIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD. Dosimetry Planning
NIA MAGELLAN HEALTH RADIATION ONCOLOGY CODING STANDARD Dosimetry Planning CPT Codes: 77295, 77300, 77301, 77306, 77307, 77321, 77316, 77317, 77318, 77331, 77399 Original Date: April, 2011 Last Reviewed
More informationCan we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy
Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy David Shepard, Ph.D. Swedish Cancer Institute Seattle, WA Timothy D. Solberg, Ph.D. University of Texas Southwestern
More informationChapters from Clinical Oncology
Chapters from Clinical Oncology Lecture notes University of Szeged Faculty of Medicine Department of Oncotherapy 2012. 1 RADIOTHERAPY Technical aspects Dr. Elemér Szil Introduction There are three possibilities
More informationGuidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy
Guidelines for the use of inversely planned treatment techniques in Clinical Trials: IMRT, VMAT, TomoTherapy VERSION 2.1 April 2015 Table of Contents Abbreviations & Glossary... 3 Executive Summary...
More informationLung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014
Lung Spine Phantom Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014 The study groups are requesting that each institution keep the phantom for no more than 2 week. During this
More informationEvaluation of Dosimetry Check software for IMRT patient-specific quality assurance
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 3, 2015 Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance Ganesh Narayanasamy, Travis Zalman, Chul S. Ha,
More informationThe RPC s Evaluation of Advanced Technologies. AAPM Refresher Course July 29, 2008 Geoffrey S. Ibbott, Ph.D. and RPC Staff
The RPC s Evaluation of Advanced Technologies AAPM Refresher Course July 29, 2008 Geoffrey S. Ibbott, Ph.D. and RPC Staff 1 http://rpc.mdanderson.org Supported by: NCI grants CA10953 and CA81647, and an
More informationIntroduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology
Introduction of RapidArc TM : an example of commissioning and implementing a QA programme for a new technology Philip Mayles Clatterbridge Centre for Oncology, Wirral, UK 1 What is RapidArc (or VMAT)?
More informationA TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *
Romanian Reports in Physics, Vol. 66, No. 2, P. 394 400, 2014 A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM * D. ADAM 1,2,
More informationAlbert Lisbona Medical Physics Department CLCC Nantes Atlantique a
The Equipment : safety, commissioning, re commissioning calibration : Equipements : sûreté, recette, modification calibration A medical physicist point of view. Albert Lisbona Medical Physics Department
More informationA VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *
Romanian Reports in Physics, Vol. 66, No. 2, P. 401 410, 2014 A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM * M. D. SUDITU 1,2, D. ADAM 1,2, R. POPA 1,2, V. CIOCALTEI
More informationIMRT/IGRT Patient Treatment: A Community Hospital Experience. Charles M. Able, Assistant Professor
IMRT/IGRT Patient Treatment: A Community Hospital Experience Charles M. Able, Assistant Professor Disclosures I have no research support or financial interest to disclose. Learning Objectives 1. Review
More information8/2/2012. Transitioning from 3D IMRT to 4D IMRT and the Role of Image Guidance. Part II: Thoracic. Peter Balter, Ph.D.
8/2/2012 Transitioning from 3D IMRT to 4D IMRT and the Role of Image Guidance Part II: Thoracic Peter Balter, Ph.D. Disclosure Dr. Balter is Physics PI on a trial comparing Cyberknife based SBRT with surgery,
More informationFeasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment
Chinese Journal of Cancer Original Article Feasibility of the partial-single arc technique in RapidArc planning for prostate cancer treatment Suresh Rana 1 and ChihYao Cheng 2 Abstract The volumetric modulated
More informationActivity report from JCOG physics group
2013.5.9 Global Harmonization Group meeting ICCR2013 @ Melbourne Activity report from JCOG physics group 1 Hokkaido University, Graduate School of Medicine, 2 National Cancer Center, Center for Cancer
More informationFEE RULES RADIATION ONCOLOGY FEE SCHEDULE CONTENTS
Tel: +27-21-9494060 Fax: +27-21-9494112 E-mail: leon.gouws@cancercare.co.za FEE RULES RADIATION ONCOLOGY FEE SCHEDULE CONTENTS 1. EXTERNAL BEAM RADIATION... 2 2. PLANNING OF TREATMENT... 2 3. DELIVERY
More informationLimits of Precision and Accuracy of Radiation Delivery Systems
Limits of Precision and Accuracy of Radiation Delivery Systems Jean M. Moran, Ph.D. 1 and Timothy Ritter, Ph.D. 2 1 University of Michigan, Ann Arbor, Michigan 2 Ann Arbor Veterans Affairs Hospital, Ann
More informationStereotaxy. Outlines. Establishing SBRT Program: Physics & Dosimetry. SBRT - Simulation. Body Localizer. Sim. Sim. Sim. Stereotaxy?
Establishing SBRT Program: Physics & Dosimetry Lu Wang, Ph.D. Radiation Oncology Department Fox Chase Cancer Center Outlines Illustrate the difference between SBRT vs. CRT Introduce the major procedures
More information3D Pre-treatment Dose Verification for Stereotactic Body Radiation Therapy Patients
3D Pre-treatment Dose Verification for Stereotactic Body Radiation Therapy Patients G Asuni *1, T vanbeek 1, E VanUtyven 1, P McCowan 1,2, and B.M.C. McCurdy 1,2,3 1 Medical Physics Department, CancerCare
More informationLinac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR
Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR PhD, FAAPM, FACR, FASTRO Department of Radiation Oncology Indiana University School of Medicine Indianapolis, IN, USA Indra J. Das,
More informationCyberKnife Technology in Ablative Radiation Therapy. Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017
CyberKnife Technology in Ablative Radiation Therapy Jun Yang PhD Cyberknife Center of Philadelphia Drexel University Jan 2017 Objectives Components and work flow of CyberKnife Motion management of CyberKnife
More informationFuture upcoming technologies and what audit needs to address
Future upcoming technologies and what audit needs to address Dr R.I MacKay History of audit Absolute dose - Simple phantom standard dose measurement Point doses in beams - Phantoms of relatively simple
More informationOverview of Advanced Techniques in Radiation Therapy
Overview of Advanced Techniques in Radiation Therapy Jacob (Jake) Van Dyk Manager, Physics & Engineering, LRCP Professor, UWO University of Western Ontario Acknowledgements Glenn Bauman Jerry Battista
More informationA Dosimetric Comparison of Whole-Lung Treatment Techniques. in the Pediatric Population
A Dosimetric Comparison of Whole-Lung Treatment Techniques in the Pediatric Population Corresponding Author: Christina L. Bosarge, B.S., R.T. (R) (T) Indiana University School of Medicine Department of
More informationFROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE. Geoffrey S. Ibbott, Ph.D. June 20, 2017
FROM ICARO1 TO ICARO2: THE MEDICAL PHYSICS PERSPECTIVE Geoffrey S. Ibbott, Ph.D. June 20, 2017 1 DISCLOSURES My institution holds Strategic Partnership Research Agreements with Varian, Elekta, and Philips
More informationIGRT1 technologies. Paweł Kukołowicz Warsaw, Poland
IGRT1 technologies Paweł Kukołowicz Warsaw, Poland Minimal prerequisite for good, efficient radiotherapy ICTP 2015 Paweł Kukołowicz 2/29 Minimal prerequisite for good, efficient radiotherapy Well trained
More informationData Collected During Audits for Clinical Trials. July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff
Data Collected During Audits for Clinical Trials July 21, 2010 Geoffrey S. Ibbott, Ph.D. and RPC Staff RPC Programs Assure... Constancy of basic machine calibration (TLD/OSLD Audits) Validity of treatment
More informationDosisverifikation mit Delta 4 Discover während der Behandlung
Dosisverifikation mit Delta 4 Discover während der Behandlung Anders Adolfson, Regional Sales Manager at Scandidos AK IMRT 2015 in Erlangen, March 19 th 2015 Agenda Which problem does Delta 4 Discover
More informationAbstract: A National Project for the in-vivo dosimetry in radiotherapy: first results
Abstract: A National Project for the in-vivo dosimetry in radiotherapy: first results A.Piermattei 1, L. Azario 1, S. Cilla 2, A.Fidanzio 1, F.Greco 1, M.T.Russo 3, S. Zucca 4 1 Istituto di Fisica e Unità
More informationIntensity-Modulated and Image- Guided Radiation Treatment. Outline. Conformal Radiation Treatment
Intensity-Modulated and Image- Guided Radiation Treatment J. Daniel Bourland, PhD Professor Departments of Radiation Oncology, Physics, and Biomedical Engineering Wake Forest University School of Medicine
More informationEric E. Klein, Ph.D. Chair of TG-142
Eric E. Klein, Ph.D. Chair of TG-142 Professor of Radiation Oncology Washington University St. Louis, MO 2010 AAPM Annual Meeting Med. Phys. 21(4) 1994 Performance-based, comprehensive guidelines for preventing
More informationThe objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical
The objective of this lecture is to integrate our knowledge of the differences between 2D and 3D planning and apply the same to various clinical sites. The final aim will be to be able to make out these
More informationThe Physics of Oesophageal Cancer Radiotherapy
The Physics of Oesophageal Cancer Radiotherapy Dr. Philip Wai Radiotherapy Physics Royal Marsden Hospital 1 Contents Brief clinical introduction Imaging and Target definition Dose prescription & patient
More informationSecond Symposium on Precision Image-Guided Small Animal RadioTherapy, Vancouver, Canada, August
Second Symposium on Precision Image-Guided Small Animal RadioTherapy, Vancouver, Canada, August 11-13 2014 Program: Second Symposium on Precision Image-Guided Small Animal RadioTherapy, Aug 11-13, 2014
More informationCredentialing for Clinical Trials -IGRT. Evidence Based Radiation Oncology. Levels of Clinical Evidence. Why Credentialing?
Acknowledgements Credentialing for Clinical Trials -IGRT Invitation from Organizers RTOG Headquarter QA Team ATC Collaborators Evidence Based Radiation Oncology Clinical Trials From Collaborative Groups
More informationOutline. Chapter 12 Treatment Planning Combination of Beams. Opposing pairs of beams. Combination of beams. Opposing pairs of beams
Chapter 12 Treatment Planning Combination of Beams Radiation Dosimetry I Text: H.E Johns and J.R. Cunningham, The physics of radiology, 4 th ed. http://www.utoledo.edu/med/depts/radther Outline Combination
More informationHampton University Proton Therapy Institute
Hampton University Proton Therapy Institute Brief introduction to proton therapy technology, its advances and Hampton University Proton Therapy Institute Vahagn Nazaryan, Ph.D. Executive Director, HUPTI
More informationIntroduction. Modalities used in imaging guidance. Flat panel detector. X-ray Imaging Dose to Patients in the Era of Image-Guided Radiation Therapy
X-ray Imaging Dose to Patients in the Era of Image-Guided Radiation Therapy George Ding, Ron Price, Charles Coffey Vanderbilt-Ingram Cancer Center Vanderbilt University Medical Center, Nashville, TN Introduction
More informationFlattening Filter Free beam
Dose rate effect in external radiotherapy: biology and clinic Marta Scorsetti, M.D. Radiotherapy and Radiosurgery Dep., Istituto Clinico Humanitas, Milan, Italy Brescia October 8th/9th, 2015 Flattening
More informationChanging Paradigms in Radiotherapy
Changing Paradigms in Radiotherapy Marco van Vulpen, MD, PhD Mouldroomdag-2015 Towards the elimination of invasion 1 NIH opinion on the future of oncology Twenty-five years from now,i hope that we won
More informationADVANCES IN RADIATION TECHNOLOGIES IN THE TREATMENT OF CANCER
ADVANCES IN RADIATION TECHNOLOGIES IN THE TREATMENT OF CANCER Bro. Dr. Collie Miller IARC/WHO Based on trends in the incidence of cancer, the International Agency for Research on Cancer (IARC) and WHO
More informationEvaluation of Dynamic Delivery Quality Assurance Process for Internal Target Volume Based RapidArc
Original Article PMP Progress in Medical Physics 28(4), December 217 https://doi.org/1.14316/pmp.217.28.4.181 pissn 258-4445, eissn 258-4453 Evaluation of Dynamic Delivery Quality Assurance Process for
More informationIntensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies
Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies ICPT School on Medical Physics for Radiation Therapy Justus Adamson PhD Assistant Professor Department of Radiation
More informationTo Reduce Hot Dose Spots in Craniospinal Irradiation: An IMRT Approach with Matching Beam Divergence
SCIENCE & TECHNOLOGY To Reduce Hot Dose Spots in Craniospinal Irradiation: An IMRT Approach with Matching Beam Divergence Alburuj R. Rahman*, Jian Z. Wang, Dr. Z. Huang, Dr. J. Montebello Department of
More informationIMAT: intensity-modulated arc therapy
: intensity-modulated arc therapy M. Iori S. Maria Nuova Hospital, Medical Physics Department Reggio Emilia, Italy 1 Topics of the talk Rotational IMRT techniques: modalities & dedicated inverse-planning
More informationElectron Beam ET - Reloaded Therapy - Reloaded
8/4/216 Electron Beam ET - Reloaded Therapy - Reloaded Qiuwen Wu, Ph.D. Department of Radiation Oncology Duke University 1 Introduction: e vs. γ vs. p Electron Photon Proton Depth dose and lateral profiles
More informationBorges C 1, Zarza- Moreno M 2, Teixeira N 2, Vaz P 3 1
Borges C 1, Zarza- Moreno M 2, Teixeira N 2, Vaz P 3 1 Medicalconsult SA, Lisboa, Portugal; 2 Escola Superior de Tecnologias da Saúde, Lisboa, Portugal; 3 InsEtuto Tecnológico e Nuclear, InsEtuto Superior
More informationUnrivaled, End-to-End
PHANTOMS Unrivaled, End-to-End Stereotactic QA Industry-leading 0.1mm accuracy minimizes errors at each link in the stereotactic quality assurance chain. Stereotactic radiosurgery (SRS) is governed by
More informationIMRT Planning Basics AAMD Student Webinar
IMRT Planning Basics AAMD Student Webinar March 12, 2014 Karen Chin Snyder, MS Senior Associate Physicist Department of Radiation Oncology Disclosures The presenter has received speaker honoraria from
More informationClinical Impact of Couch Top and Rails on IMRT and Arc Therapy
Texas Medical Center Library DigitalCommons@TMC UT GSBS Dissertations and Theses (Open Access) Graduate School of Biomedical Sciences 8-2011 Clinical Impact of Couch Top and Rails on IMRT and Arc Therapy
More informationImplementing SBRT Protocols: A NRG CIRO Perspective. Ying Xiao, Ph.D. What is NRG Oncology?
Implementing SBRT Protocols: A NRG CIRO Perspective Ying Xiao, Ph.D. What is NRG Oncology? One of five new NCI-supported National Clinical Trials Network (NCTN) groups. NCTN officially started March 1,
More informationClinical Implications of High Definition Multileaf Collimator (HDMLC) Dosimetric Leaf Gap (DLG) Variations
Original Article PROGRESS in MEDICAL PHYSICS 27(3), Sept. 2016 http://dx.doi.org/10.14316/pmp.2016.27.3.111 pissn 2508-4445, eissn 2508-4453 Clinical Implications of High Definition Multileaf Collimator
More informationUNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies
UNIVERSITY OF WISCONSIN-LA CROSSE Graduate Studies A SINGLE INSTITUTION S EXPERIENCE IN DEVELOPING A PURPOSEFUL AND EFFICIENT OFF-LINE TECHNIQUE FOR ADAPTIVE RADIOTHERAPY IN A CLINICAL ENVIRONMENT A Research
More informationSmall field dosimetry, an example of what a Medical Physicist does (& some more examples) A/PROF SCOTT CROWE MEDICAL PHYSICIST
Small field dosimetry, an example of what a Medical Physicist does (& some more examples) A/PROF SCOTT CROWE MEDICAL PHYSICIST What is a Medical Physicist? Medical physics application of physics concepts
More informationMeasurement Guided Dose Reconstruction (MGDR) Transitioning VMAT QA from phantom to patient geometry
Measurement Guided Dose Reconstruction (MGDR) Transitioning VMAT QA from phantom to patient geometry Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology Conflict of interest None Acknowledgement: Jim
More informationIndependent Dose Verification for IMRT Using Monte Carlo. C-M M Charlie Ma, Ph.D. Department of Radiation Oncology FCCC, Philadelphia, PA 19111, USA
Independent Dose Verification for IMRT Using Monte Carlo C-M M Charlie Ma, Ph.D. Department of Radiation Oncology FCCC, Philadelphia, PA 19111, USA Outline Why Monte Carlo for IMRT QA? Experimental verification
More informationVerification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film
Verification of treatment planning system parameters in tomotherapy using EBT Radiochromic Film E.B.Rajmohan¹, Pratik Kumar¹, Bhudatt Paliwal,² David Westerly², N.Gopishankar³, R.K.Bisht³, D.Tewatia²,
More informationSRS Uncertainty: Linac and CyberKnife Uncertainties
SRS Uncertainty: Linac and CyberKnife Uncertainties Sonja Dieterich, PhD Linac/CyberKnife Technological Uncertainties 1 Linac Mechanical/Radiation Isocenters Depuydt, Tom, et al. "Computer aided analysis
More informationPHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015)
PHYS 383: Applications of physics in medicine (offered at the University of Waterloo from Jan 2015) Course Description: This course is an introduction to physics in medicine and is intended to introduce
More informationAre Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?
Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program? Can you currently use direct documentation and measurement of delivered dose to ensure you did not underdose or
More informationIMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)
IMRT QUESTIONNAIRE Institution: Date: / / Address: Physicist: e-mail: Telephone: Fax: Research Associate: email: Telephone: Fax: Dosimetrist: email: Telephone: Fax: Responsible Radiation Oncologist(s)
More informationPotential conflicts-of-interest. Respiratory Gated and Four-Dimensional Tumor Tracking Radiotherapy. Educational objectives. Overview.
Respiratory Gated and Four-Dimensional Tumor Tracking Radiotherapy Potential conflicts-of-interest I am PI of a sponsored research agreement between Stanford University and Varian Medical Systems P Keall
More informationVMAT plans for treatment prostate cancer: Dosimetric verifications and comparison with 3D-CRT and IMRT
VMAT plans for treatment prostate cancer: Dosimetric verifications and comparison with 3D-CRT and IMRT Poster No.: C-0520 Congress: ECR 2011 Type: Scientific Exhibit Authors: Y. Kawasaki, S. Tadokoro,
More informationIROC Lung Phantom 3D CRT / IMRT. Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015
IROC Lung Phantom 3D CRT / IMRT Guidelines for Planning and Irradiating the IROC Lung Phantom. Revised Dec 2015 The IROC requests that each institution keep the phantom for no more than 2 weeks. During
More informationImaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT
Imaging of Scattered Radiation for Real Time Tracking of Tumor Motion During Lung SBRT April 25 nd, 2015 Lung Cancer Lung cancer is the most lethal cancer: Over 224,000 new diagnoses in the U.S. predicted
More informationRadiosurgery by Leksell gamma knife. Josef Novotny, Na Homolce Hospital, Prague
Radiosurgery by Leksell gamma knife Josef Novotny, Na Homolce Hospital, Prague Radiosurgery - Definition Professor Lars Leksell The tools used by the surgeon must be adapted to the task and where the human
More informationComparison of high and low energy treatment plans by evaluating the dose on the surrounding normal structures in conventional radiotherapy
Turkish Journal of Cancer Volume 37, No. 2, 2007 59 Comparison of high and low energy treatment plans by evaluating the dose on the surrounding normal structures in conventional radiotherapy MUHAMMAD BASIM
More informationDose rate response of Digital Megavolt Imager detector for flattening filter-free beams
Received: 12 May 2017 Revised: 23 October 2017 Accepted: 10 April 2018 DOI: 10.1002/acm2.12358 RADIATION ONCOLOGY PHYSICS Dose rate response of Digital Megavolt Imager detector for flattening filter-free
More informationDosimetric Comparison: Acuros XB vs AAA
Dosimetric Comparison: Acuros XB vs AAA Leo El Hage, Chris James, Jim Frantzis, Roger Li, Venkata Sheshadri Epworth Radiation Oncology Epworth HealthCare Excellence. Everywhere. Everyday Background Epworth
More information