Beam commissioning. and annual Qa. ggggg fffff. Fastest, most accurate, most reliable relative dosimetry iba DOSIMETRY // 1

Size: px
Start display at page:

Download "Beam commissioning. and annual Qa. ggggg fffff. Fastest, most accurate, most reliable relative dosimetry iba DOSIMETRY // 1"

Transcription

1 Beam commissioning and annual Qa ggggg fffff 7 Fastest, most accurate, most reliable relative dosimetry iba DOSIMETRY // 1

2 relative dosimetry Fastest, most accurate and most reliable the Gold standard redefined the new Blue Phantom 2 For over 35 years IBA Dosimetry has been providing the highest quality dosimetry equipment and services, with more than 3,500 SATiSFieD WATeR phantom USeRS worldwide. The new Blue Phantom 2 embodies decades of expertise, research and experience in the development and clinical use of water phantom systems. Over 20,000 LinACS CoMMiSSioneD are testimony of IBA s leading competence! CoMMiSSioninG SeRviCe ADvAnTAGe! Book IBA commissioning service and get your linac commissioned much faster The Blue Phantom² is designed based on IBA s unique commissioning service field experience 5 TiMeS FASTeR DATA SCAnninG Dramatically cut your commissioning times with the Linear Diode Array: Complete profi le scanning at once Highest resolution down to 0.5 mm Find out more on page 7. FASTeST & MoST ACCURATe SeTUp WiTH ConFiDenCe The micro-leveling technology allows for extremely accurate alignment of the system to the water surface in just 2 minutes! Faster and more accurate than automated setup Avoids redundancy of validation needs of automated procedures No tank movement, no wave building certified accuracy better than ±0.1 mm CeRTiFieD ACCURACy Uncompromised commissioning accuracy for your advanced IMRT, IGRT and rotational treatments User Validated Setup: Visual checks provide highest confidence in setup accuracy. Only the Blue Phantom² is calibrated and certifi ed to guarantee highest accuracy and reproducibility of min ± 0.1mm! Have full trust in your beam profi le data! HiGHeST positioning ACCURACy Unique absolute measurements Cal alibration Cer ertificat ate Blue Phantom², Seria erial No.: Unique contact-less sensors Highest detector positioning accuracy without mechanical wear! Adaptive Scan Optimization X Y Z The Blue Phantom 2 is equipped with a unique high-precision sensor technology. Continuous absolute measurements of chamber position on all 3 axis The superior solution is a non-contact absolute position sensor (vs. typical indirect stepper motor measurements). UniQUe: ADApTive SCAn optimization Speed as well as Accuracy! ASO signifi cantly speeds up continuous and step-by-step scanning ASO overcomes the restrictions of all other systems that compromise speed vs. high resolution scanning iba Acquablue: water treatment for protecting mechanical parts and saving water from decay certified accuracy better than ±0.1 mm Looking at this new series of the Blue Phantom, I am happy to see a continuous and significant progress in accuracy, flexibility, long term mechanical stability and reliability since Wellhofer Dosimetry started Automatic scanning speed adaptation enables optimal accuracy for the different profi le segments as well as developing and producing water phantoms 35 years ago. fastest scanning where fewer data points are needed Take advantage of experience, knowhow and consequent Find out more on page 5. innovation by having a Blue Phantom 2. MANFRED WELLHÖFER 2 // iba DOSIMETRY PREDECESSOR OF IBA DOSIMETRY, INVENTOR OF WATER PHANTOMS iba DOSIMETRY // 3 You Tube Find out iba-dosimetry.com/bluephantom

3 the difference Between Good and excellent software? omnipro-accept workflow optimized omnipro-accept 7.4 Fully WoRKFLoW oriented, menu guided OmniPro-Accept software: designed to increase your efficiency and to reduce the commissioning and QA time of your Linac. SCAn optimization Select different scan speeds or data point densities in different regions of the scan. Uniquely optimizing the overall measurement time and resolution. Adaptive Scan Optimization Start page Queue Setup Data Acquisition Data Handling & Analysis RTpS Transfer ASO Adaptive Scan Optimization: This unique scanning mode ensures the shortest measuring time combined with a high spatial resolution. Time saving without compromizing accuracy! ADvAnCeD CoMMiSSioninG interface Menu guided workfl ow optimization Step-by-step and continuous scanning MoRe AUToMATeD FeATUReS Output factor determination Central axis correction via automated measurement routine TRUe WoRKFLoW efficiency QUeUe SeTUp DATA ACQUiSiTion DATA HAnDLinG & AnALySiS RTpS TRAnSFeR Advanced data processing with macros & various algorithms AUToMATiC QUeUe GeneRATion Fast & automatic data acquisition with predefi ned queues for all major TPS Save time with smart sorting algorithm for optimized scan sequences Sorting, prioritizing and multiple edits of scan queues to maximize effi ciency Intuitive setup of user specifi c queues Adjustable scanning parameters for optimized measurements 1D, 2D and 3D graphical and geometrical visualization of detector position during scanning Easy fi ltering and sorting Fast creation and export of data tables (PDD, TMR, OAR, etc.) Copy & paste to other applications, eg. MS Excel Exchange data with other IBA Dosimetry applications e.g. OmniPro-I mrt, OmniPro-Advance Accurate data analysis via standard and customizable protocols Analysis of TrueBeam / FFF scans Overlaying profi les for quantitative comparison 2D array and isodose calculation and display Library of mathematical smoothing and interpolation functions 4 // iba DOSIMETRY iba DOSIMETRY // 5

4 most efficient & most accurate linac commissioning & Qa > 5 times Faster Beam ProFile measurements ADvAnCeD CoMMiSSioninG interface OmniPro-Accept Software is tailored to make your commissioning and annual QA faster and better Menu guided workfl ows enable easy operations Unique features like the ASO scanning dramatically shorten the procedures Advanced data handling and connectivity Pre-Programmed TPS data requirements LDA-99: DRAMATiCALLy ReDUCe your CoMMiSSioninG TiMe WiTHoUT CoMpRoMiSinG HiGHeST ACCURACy instant MeASUReMenT of entire profiles Start your treatments days earlier Consistent high accuracy measurements, according to TG-106 standards interactive MiCRo-LeveLinG SySTeM For most effi cient and user validated setup of the phantoms SinGLe HAnD ConTRoL increases efficiency For easy and intuitive control of the Blue Phantom² and water reservoir CCU (CoMMon ConTRoL UniT) Its compact design integrates a controller and two independent electrometers: Simultaneous support of diodes and ionization chambers Built-in pressure & temperature sensor interfaces prepared for automatic Kt,p correction in-plane and cross-plane scanning consistency of blue phantom 2 with CC13 chamber MoST ACCURATe & MoST ReLiAbLe Blue Phantom²: the right solution for your crucial Linac commissioning From the inventor of water phantoms > 20,000 Linacs commissioned Over 35 years of experience ConSiSTenTLy ACCURATe MeASUReMenTS in X AnD y Small ionization chambers like IBA s CC-13 ensure scanning direction independent accuracy, regardless of detector movement and orientation (according to TG-106 report). LeADinG TeCHnoLoGy Highest linear diode array resolution with 99 p-type semiconductor detectors Software controlled automatic LDA-99 shift and measurements: fastest data sampling resolution down to 0.5 mm Reliable commissioning and QA of dynamic wedges and MLC fi elds Suitable for photons and electrons Online Linac adjustment with real-time dose measurement & analysis In-water and in-air measurements LDA-99 00:03 3 secs for 2.5 mm pitch (198 data points) CoMMiSSioninG TiMe SAvinG WiTH iba UniQUe TeCHnoLoGy Conventional tank blue phantom² with LDA Tank setup pdd/output factor data collection pdd/output factor data collection Comparison shows a typical Linac / RTpS commissioning: * Typical step-by-step scanning with average data resolution takes minimum 7 days ** Profile and wedge scanning with LDA saves up to 6 days in Linac commissioning *** Data Modelling typically takes 5 days but can vary depending on RTPS CoMpARiSon of beam profile ACQUiSiTion MoDULeS LDA** The whole profile at once Continuous scanning Step-by-step scanning profile scanning step-by-step* profile scanning Data modeling*** Times shown are average, based on commissioning of 3 photon energies with average 765 profiles PDD / Output Factors; Times incl. changes in machine setup, wedges, breaks and starts 00:32 03:12 Data modeling*** p p p p p p commissioning completed 6 days earlier days days more patient treatment time I have been using IBA s Blue Phantom and the innovative linear diode array during the commissioning of my Trilogy and Novalis TX Linacs. The capability to acquire profiles instantly, allowed me to collect all beam data in a fraction of the time. The speed of the LDA-99 versus a single detector is unmatched in the industry. R. RODEBAUGH, PH.D. CHESAPEAKE GENERAL HOSPITAL, CHESAPEAKE, VA 6 // iba DOSIMETRY iba DOSIMETRY // 7

5 accessories to complete Your system TMR-SeT WATeR ReSeRvoiR Online measurement of tissue maximum ratio (TMR) with fi xed source detector distance Continuous TMR depth dose curve measurement with real-time display of dose vs. water level Unique IBA high-accuracy contact-less sensor technology to accurately measure the changing water level Separate tank trolley on wheels with a polyethylene water reservoir Pump for uni-directional or bi-directional water transport Electronic pump control for TMR/TPR measurement (option) blue phantom HeLiX The smaller tank for periodic quick QA tasks and for TomoTherpy commissioning & QA. Based on Blue Phantom² technology Operated with OmniPro-Accept software and Common Control Unit 3D movement enables scanning without tank repositioning ± 0.1mm detector positioning accuracy. Certifi ed! LiFT TAbLe Find out more at iba-dosimetry.com/bluephantom Compact design: Provides full tank access without lift table bumping causing setup failures (compare to other tables with extended legs) Easy to store and convenient to drive even through narrow mazes Convenient and fast positioning of the water phantom incl. leveling frame for vertical & horizontal fi ne adjustment (electrical version) Water phantom carriage with manual or electric (telescopic) lifting 2 fi xed and 2 steerable rollers with brakes, incl. storage compartments TeMpeRATURe SenSoR The water temperature measurement is used in combination with the pressure measurement (built-in pressure sensor provided in the CCU) Automatic Kt,p correction for output factor determination Easy setup in the water tank ±0.3 C measurement accuracy DeDiCATeD QUALiTy DeTeCToRS ACCURACy FoR ALL AppLiCATionS IBA Dosimetry offers a complete range of detectors, including ionization chambers and semiconductor detectors. The Universal Holders enable fast and fl exible mounting of all chambers and detectors in vertical and horizontal orientation Calibrated in our Calibration Laboratory, accredited by DAkkS and member of the IAEA/WHO SSDL ConneCTiviTy The Blue Phantom is connected to the hospital network via Ethernet: Standard Ethernet cable instead of special cables East to connect, easy and inexpensive to replace! The main things I look for in a scanning system are positional accuracy, reproducibility, and stability. The folks at IBA Dosimetry definitely got it right with this one. The typical potentiometers and stepper-motors of other systems are replaced with contact-less absolute measurement sensors. This ingenious piece of engineering provides 0.1 mm accuracy, ± 0.1 mm reproducibility, and unsurpassed l ong-term stability. Over 20 years, I have used many systems from many vendors. This is by far the best! SCOTT R. CONLEY, MS, DABR CAROLINAEAST HEALTH SYSTEM, NEW BERN, NORTH CAROLINA, USA 8 // iba DOSIMETRY iba DOSIMETRY // 9

6 BudGets may differ. customize to Your needs, without compromising on QualitY MAXiMUM FLeXibiLiTy FoR A WiDe RAnGe of USe AnD budget! The Blue Phantom2 is the only water phantom customizable to your specific requirements: Select among various premium value adding features Gain maximum flexibility to configure to your individual needs and budget Choose from advanced options designed to save time and increase accuracy and flexibility MAXiMiZe efficiency MAXiMiZe ACCURACy increase FLeXibiLiTy instant MeASUReMenT of entire profiles UniQUe ASo ADApTive SCAn optimization SoFTWARe ConTRoLLeD CoMMon ConTRoL UniT 5x faster scanning Combine speed AND accuracy! Selectable input: floated or grounded flexible use of various IBA detectors 3 secs for 2.5 mm pitch (198 data points) with LDA Without moving the tank, without wave building extend your SKiLLS physics SeRviCeS UTiLiZe iba MAnpoWeR AnD expertise CALibRATion SeRviCe CeRTiFieD ACCURACy FoR your TooLS output FACToR TAbLe Determination of output factors Comparison in graphic charts and tables AD AC E UpGRADe your efficiency in CoMMiSSioninG & AnnUAL QA! RFA -300 BLUE PHANTOM (generation 1) NEW BLUE PHANTOM 2 WeDGe CHeCK MoDULe In just 2 minutes CAX CoRReCTion Central axis check Measurements with automated CAX correction Continuous measurement of TMR curves with realtime display le nt p to ex e TRAininG CoURSeS Wedge factor and angle determination TMR-SeT 10 // iba DOSIMETRY iba ACADeMy TRAininG Y Fast and complete tank drainage without manual lifting Accurate horizontal alignment of the scanning mechanism enhance your existing AppLiCATionS ta SLAnTeD bottom MiCRo-LeveLinG FRAMe product UpGRADeS f ro m For fast and accurate measurements Optimal Workflows and Highest Efficiency Treatment safety with best QA standards M ConTinUoUS SCAnninG MoDe Define and automatically execute most optimal scan resolution vs. scan speed for different beam profile segments ise Your satisfaction as a customer and user of IBA equipment is in the center of all of our activities. Therefore we strive for innovative SoLUTionS AnD SeRviCeS with one goal in mind: to constantly improve your dosimetry and to enable you to do your dosimetry the FASTeST, MoST ACCURATe and MoST ReLiAbLe way! rt MoDULAR DeSiGn iba Advancements in Linac technology demand more and more data collection during commissioning. Ensure you keep up with unique IBA innovations that will enable you to save valuable time and provide highest accuracy. Enhance your knowledge, maximize your utilization, operate most efficient! Discover the curriculum of the International Competence Center ICC and our online webinars: Application Courses Product Training Clinical Sessions Adaptive Scan Optimization and LDA-99 provide dramatically faster data scanning with high accuracy THin WinDoW Highest accuracy with contact-less sensor technology, certified to +/- 0.1mm! Enabling horizontal irradiations through only 3 mm PMMA Software upgrades for your existing RFA-300 and Blue Phantom (generation 1): Boost your workflow efficiency and ease of use Find the latest upgrade solutions and CAReprogram information online! iba DOSIMETRY // 11

7 Reliability you can count on: Water Tank Exterior water tank dimensions (LxWxH): Blue Phantom 2 with OmniPro-Accept (V 7) 675 mm x 645 mm x 560 mm 480 mm x 480 mm x 410 mm Fastest, 0.1 mm Most Accurate and Scanning volume (LxWxH): Position resolution: Position accuracy: ± 0.1 mm Position reproducibility: ± 0.1 mm Speed: Positioning Speed: max. 50 mm/s; Scanning Speed: max. 25 mm/s Approximate volume: 200 l Wall thickness / material: 15 mm / acrylic Weight (empty): 45 kg Common Control Unit (CCU) For over 35 years IBA Dosimetry has been Maximum resolution: 0.5 fa at 0.4 na full scale; 5 fa at 40 na full scale; 0.5 pa at 4 ua full scale providing the highest quality dosimetry Full scale range: 0.4 na / 40 na / 4uA Leakage current: equipment < 200 fa, to typically more <20 than fa satisfied Time constant: 20 ms Bias voltage range: customers ± 50 through worldwide. ± 500 V Trigger interface: RS 485 (custom specific) The new Blue Phantom 2, with over 25,000 Common interface: ETHERNET (100BaseT) Main supply: Linacs 100 commissioned, 240 V AC ± 10 %; 50/60 embodies Hz decades LDA-99SC of expertise, research and experience in Number of diodes: 99 Diode spacing: the development 5 mm (center-to-center) of water phantom Diode specifications Type of silicon: systems. Hi-pSi diode detectors Chip size: 2.45 mm x 2.45 mm Diameter of active area: 2.0 mm ggggg Sensitivity: 35 gy/nc Effective measurement point: fffff <1 mm Positioning in phantom: 0, 45, 90 and 135 degrees Water Reservoirs Pump direction: bi-directional (HA05) / uni-directional (HA06) Tank volume: 220 l Flow control: 20 l/min Dimensions (LxWxH): 970 mm x 660 mm x 830 mm Weight (empty): 70 k Lift Tables Operation: manual (HA01)/ electric (HA03) Vertical range: mm / mm Vertical adjustable range (tilt): ± 15 mm / 20 mm Horizontal adjustable range: 15 mm in X/Y direction Rotation in XY plane: n.a. / ± 5 Table size: 635 mm x 635 mm / 680 mm x 680 mm Dimensions (LxWxH): 790 mm x 630 mm x 660 mm / 840 mm x 680 mm x 660 mm Weight (empty): 69 kg / 116 kg TMR Set (requires Water Reservoir HA05) Scan length: 30 cm Position reproducibility: ± 0.3 mm Filling / draining speed: 50 mm / min emxx Number of channels: 99+1 Measurement mode: dose, dose rate, real-time, simultaneous measurements of all channels Characteristics (Dose/Dose rate) Input range: 0 na to 500 na Accuracy: ± 1 % for currents > 10 pa Resolution: 100 fc (for charge values up to 0.2 mc) A/D converter: 128 simultaneous working A/D converters Dimensions (LxWxH): 320 mm x 265 mm x 70 mm Weight: 3.75 kg Minimum Computer Requirements Operating systems (US-English versions only): Processor: RAM: Graphics card: Screen resolution: Network: Free space on harddisk: Windows XP Professional, Service Pack 3, 32 bit Windows Vista Ultimate, Service Pack 2, 32 bit Windows 7 Enterprise, Service Pack 2, 32 bit and 64 bit Dual Core (or equivalent), 2 GHz or better 2 GB of RAM DirectX 9c compatible, 256 MB video RAM, no shared memory minimum 1280x1024 with 32 bit color Ethernet (RJ-45) connection to connect controllers (e.g. CCU, emxx) minimum 300 MB free disk space before installation and 80 MB after installation: For archiving of data, much more disk space is needed Made in Germany. Supported globally. info@iba-dosimetry.com Europe, Middle East, Africa IBA Dosimetry GmbH Bahnhofstr Schwarzenbruck, Germany Tel.: Fax: North America, Latin America IBA Dosimetry America 3150 Stage Post Drive, Suite 110 Bartlett, TN 38133, USA Tel.: Fax: Asia Pacific IBA Dosimetry Asia Pacific No.6, Xing Guang Er Jie Beijing OPTO-mechatronics Industrial Park (OIP), Tongzhou District Beijing , China Tel.: Fax: Discover more Online RT-BR-BP2-Rev Q500 IBA 2012 All rights reserved Manufacturer: IBA Dosimetry GmbH Technical data is subject to change without prior notice. Depicted product images and specifications may differ from the actual scope of delivery // IBA DOSIMETRY

8 3D Treatment Verification and Patient Dose Analysis COMPASS: Maximize Efficiency, Minimize Errors, Better Outcomes

9 2 IBA DOSIMETRY 3D PLAN VERIFICATION

10 Radiation Therapy is advancing rapidly, improving treatment accuracy but also introducing new uncertainties and risks. Ensure patient safety and better treatment outcomes by eliminating the unknown. COMPASS provides you critical details needed for confident plan verification and approval.

11 COMPASS 3D Treatment Plan Verification at a glance Physics Analysis Conventional phantom-based QA is a generally accepted method to validate the treatment plan based on comparison of measured vs. planned dose. These common QA techniques are reaching their limits* when advanced treatments require a more advanced analysis. In cases of discrepancies a full understanding of the clinical impact and relevance is needed. True Volumetric Measurement: Linac output and gantry angle COMPASS Efficiency: Fast pass / fail analysis reference measured comparison analysis [ ] We used the unique COMPASS solution for verifi cation of over 220 patient plans in the fi rst 18 months after introduction. COMPASS was primarily used for QA of complex IMRT treatment plans for H&N but also in some cases like prostate, sarcomas, and carcinomas of the skin. Erik Korevaar, PhD, Medical Physicist, Radiotherapy Department of the University Medical Center Groningen, Netherlands 4 IBA DOSIMETRY 3D PLAN VERIFICATION * Conventional IMRT QA Analysis Metrics Do Not Predict Clinically-Relevant Patient Dose Errors, Nelms BE, Zhen H, Tomé WA. Submitted for publication, May 2010.

12 Patient-based Clinical Evaluation COMPASS builds on our past knowledge and provides the power to verify dose based on the patient s individual CT data set in addition to the common QA tools: The Physicist and the Radiation Oncologist can now review plans on a common understandable platform, enabling better plan verifi cation and safer treatments. COMPASS Accuracy and Reliability: Evaluation of the clinical relevance of discrepancies relating physics analysis to 3D patient dose reference COMPASS 3D dose difference Patient CT DVH, 3D dose difference and 3D gamma analysis at organ level 5 IBA DOSIMETRY 3D PLAN VERIFICATION

13 COMPASS Efficiency: Fastest Plan Analysis COMPASS provides a fast and familiar plan QA solution based on standard physics acceptance criteria. This plan QA solution allows a rapid pass or fail analysis. In case of substantial dose discrepancies of plan vs. measurements COMPASS extends into 3D patient anatomy based analysis. reference measured comparison analysis Using the MatriXX-based pre-treatment confi guration it has been shown that the COMPASS system can achieve the necessary precision in plan verifi cation while shortening the time required for pre-treatment QA. Prof. Dr. Frank Lohr, University Heidelberg, Universitätsmedizin Mannheim, Germany 6 IBA DOSIMETRY 3D PLAN VERIFICATION

14 Measurement accuracy down to the details seamless measurement of the whole plan delivery accurate analysis of rotational plans individual check for each IMRT segment (step and shoot or dynamic) precise measurement of gantry angle per frame rapid response measurement with sampling rate up to 20 frames/sec Comprehensive analysis fast analysis of response difference (plan vs. delivered) precise evaluation per fi eld or for each segment/control point reliable check even for small MLC errors Fast overview of all frames (planned vs. measured) overview provides fast response comparison on control-point level analytic overview of delivery process check reference vs. planned consistency for small fl uctuations Predicted Measured Reporting fast one-click automatic generation of comprehensive report patient individual reporting for electronic records, print or export to Excel add patient anatomy to the equation 7 IBA DOSIMETRY 3D PLAN VERIFICATION

15 COMPASS Accuracy and Reliability: With Patient Anatomy COMPASS enables the Radiation Therapy Team to combine their physics and clinical expertise for a full treatment evaluation based on the clinical protocol. The team benefi ts from a complete understanding of the clinical relevance of dose discrepancies and necessary corrective action, speeding up processes and enabling earlier and better patient treatment. 3D dose difference reference COMPASS COMPASS output display on patient CT will be very beneficial for our physicians. [ ] COMPASS will take a significant place for our IMRT and Rotational treatment plan verification. Charles W. Coffey, Ph.D. and Jostin Brian Crass, M.S., Radiation Oncology Department, Vanderbilt-Ingram Cancer Center, USA 8 IBA DOSIMETRY 3D PLAN VERIFICATION

16 Fastest overview of the entire plan immediate FAIL alert if predefi ned prescription doses and tolerances are missed automatic OAR and PTV analysis based on your clinical protocols TPS DVH Measured comparative DVH enables fastest assessment of reference (TPS) vs. delivered dose full visualization fl exibility (all ROI s or one by one) Reliable analysis of dose discrepancy details the % difference between reference (TPS) and actual measured dose (Compass) is determined in the patient CT immediate understanding of dose discrepancies in single organs Most accurate verification of clinical relevance of errors patient dose guided decisions instead of traditional physics pass criteria analyze doses in absolute Gy (gray) values; verify target average dose and homogeneity, analyze OAR dose constraints understand clinical relevance, gain full treatment confi dence and better outcome Comprehensive Reporting indication specifi c template for consistent report generation including DVH, displays of planned and reference patient dose, dose difference etc. COMPASS: Maximize Efficiency, Minimize Errors, Better Outcomes 9 IBA DOSIMETRY 3D PLAN VERIFICATION

17 Workflow Driven Analysis Patient Data True 3D Volumetric Measurement MatriXX Evolution mounted on Gantry enables full 360 data acquisition for true 3D dose reconstruction and analysis Treatment Plan (reference) 10 IBA DOSIMETRY 3D PLAN VERIFICATION

18 Visualize, Verify, Validate Patient CT import Plan Delivery Verification Fast comparison and analysis planned & measured data import Patient Based Verification 3D dose comparison, DVH analysis Treatment Validation Protocol-based PASS/FAIL criteria, reporting in comparative DVH/table COMPASS provides instant and most reliable plan verification based on the user s individual clinical treatment protocol. Tolerances, maximum/minimum doses and dose homogeneity can be set per critical organ and treatment volume. 11 IBA DOSIMETRY 3D PLAN VERIFICATION

19 3D volumetric measurement with all 1020 detectors permanently in the beam PIC (Ionization Chamber Technology) for optimum detector performance and stability angle sensor to precisely correlate linac output and gantry angle upgrade path available for exisiting MatriXX users 12 IBA DOSIMETRY 3D PLAN VERIFICATION

20 Maximize Efficiency COMPASS relates to 3D patient dose revealing the clinical relevance of dose discrepancies. Minimize Errors COMPASS gives you the power to analyze the entire treatment chain from the plan to the patient. Better Outcome COMPASS provides a platform to combine the expertise of the RT team, putting the clinical protocol in the center of plan verification. 13 IBA DOSIMETRY 3D PLAN VERIFICATION

21 Add Patient Anatomy into your equation Plan QA + Patient Anatomy = Accuracy Gamma Analysis + Patient Anatomy = Efficiency Expertise + Patient Anatomy = Better Outcome 14 IBA DOSIMETRY 3D PLAN VERIFICATION

22

23 IBA Activities in a Nutsahell IBA delivers solutions of unprecedented precision with a focus in the fields of cancer diagnosis and therapy. Diagnostics Portfolio Safer Imaging, Earlier Cancer Detection Advanced quality assurance devices for Medical Imaging: Solutions for x-ray diagnosis and patient-dose monitoring Unique expertise in the design of cyclotrons: Solutions for radiopharmaceutical tracers incl. production and distribution Radiation Therapy Portfolio Fighting Cancer Undisputed leader in Particle Therapy: enabling the most precise and effective radiation therapy Industry leading QA and dosimetry solutions: maximizing efficiency, minimizing errors, better outcomes Imaging fiducial markers: Visicoil enabling high precision tumor targeting Sterilization & Ionization Improving Hygiene and Safety of Everyday Life Electron accelerators and high power X-Ray solutions: applied in many industries to sterilize medical devices, to cold pasteurize food products or to improve polymer properties IBA a Belgian company, is listed on the paneuropean stock exchange EURONEXT and its Annual Reports can be downloaded on the Website: Contact details: info@iba-dosimetry.com Europe, Middle East, Africa IBA Dosimetry GmbH Bahnhofstr Schwarzenbruck, Germany Tel.: Fax: North America, Latin America IBA Dosimetry America 3150 Stage Post Drive, Suite 110 Bartlett, TN 38133, USA Tel.: Fax: Asia Pacific IBA Dosimetry Asia Pacific No.6, Xing Guang Er Jie Beijing OPTO-mechatronics Industrial Park (OIP), Tongzhou District Beijing , China Tel.: Fax: COMPASS software is developed in cooperation with RaySearch Laboratories AB. patent pending MatriXX was designed and built in cooperation with Torino University and INFN Technical data is subject to change without prior notice. RT-BR-E-COMPASS Rev IBA 2011 / All rights reserved Manufacturer: IBA Dosimetry GmbH

24 Quality Control in Medical x-ray Imaging Multimeter, kv-meter, Dosimeter

25 MagicMaX is the optimized solution for advanced beam verification and quality assurance in all x-ray imaging modalities Radiography Fluoroscopy Dental Mammography The multimeter solution Uniquely Efficient enabling one-shot full QA Uniquely Versatile integrating in any workflow and QA need Uniquely Powerful providing expert level comprehensive data Uniquely

26 Uniquely Efficient the one shot full QA solution 1 The one-shot full QA solution Position micro footprint detector on the test plate MagicMaX in combination with test plate Primus empowers fastest and earliest quality assurance. dose acceptance plus image quality in one single setup with only one x-ray exposure 2 Fastest workflow, shorter QA, higher machine uptime One single exposure fast setup on the imaging device plug and play solution by design one exposure only, no need for repeated room entering 3 Full QA with full beam data......and image quality with unobstructed view at the test plate

27 Uniquely Versatile adaptable to any workflow QA need MagicMaX for all needs Fully customizable solution to fit your needs, your workflow and your budget MagicMaX mas-clamp Unique invasive and noninvasive measurements integrated in one tool Flexible computer hardware Use your own laptop or optional IBA mini notebook MagicMaX Multimeter with connected: XR-multidetector for Radiography, Fluoroscopy and Dental XM multidetector for Mammography Connect a second dose sensor to the MagicMaX for simultaneous entrance and exit dose measurement Connect the MagicMaX masclamp* for unique invasive and noninvasive measurements integrated in one tool *availability pending Connect the MM-LS MagicMaX Light Probe and verify lux measurements of viewing boxes, image intensifier output and x-ray light fields within a measuring range of 0.1 lx - 10,000 lx Additional dose detectors attachable to MagicMaX: Detector RQM - flexible dose detector for mammography Detector RQA - flexible dose detector for radiography, fluoroscopy, dental

28 Uniquely Powerful for conventional and digital applications Comprehensive! MagicMaX is designed to combine workflow efficiency with comprehensive data recording and analysis, making the solution the powerful tool from quick checks down to the most demanding expert level measurements. Proven, Certified & Calibrated MagicMaX has been proven by leading institutions such as the PTB Germany. High quality measurements for QA reliability Simultaneous measurements of kvp, PPV, time, dose, dose rate, filtration and more... Highest 0.1ms time resolution for best data quality Measurement of HVL (half value layer) Most accurate pulse information Anode ripples detectable kvp / PPV Dose Dose Rate Time HVL Waveform MagicMaX -Rad/Flu/Dent kv 50 ngy - 50 Gy 160 ngy/s mgy/s 0.2 ms s mm Al PPV, internal & external* dose rate, mas* MagicMaX -Mam kv * 50nGy - 50Gy 160 ngy/s mgy/s 0.2 ms s mm Al PPV, internal & external* dose rate, mas* MagicMaX -Dent kv 50 ngy - 50 Gy 160 ngy/s mgy/s 0.2 ms s mm Al PPV, internal dose rate, mas** * depending on Target/Filtration combination **depending on detector availability

29 Full Control at your Finger Tips the MagicMaX Software Efficiency and Power View of your choice : configure the screen to your needs, select between large digital display, scope type waveforms, tables or cards Powerful instant storage of screenshots or data export to Excel reports Saving all recorded measurements and waveforms for future analysis Retrieve and add entire measurement sessions at any time Run MagicMaX software on several computers and obtain software upgrades z z Real waveform figure Save & open sessions Favourite view generator Export via one click MagicMaX software

30 Fully Portable Solution the MagicMaX Case Remain flexible, stay mobile: The compact MagicMaX case enables you to have your QA kit with you whenever and wherever you need it. MagicMaX & Detector in one case Flexibility & mobility zequipment protection Expandable accessories

31 Full QA Solutions extending workflow efficiency in Medical Imaging Dose readings visible from Conrol Room MagicMaX & Test Plate Primus Multi-modality x-ray imaging QA ensuring quality beams and image quality LXcan & Display Q Quality Assurance for Medical Displays ensuring quality images for safer diagnosis one-shot full QA solution advanced beam and imaging checks fastest workflow, higher machine uptime Spot-Luminance-Meter: distance & screen contact measurements uniquely combined fastest workflow guided software Complete measuring set for digital and conventional radiographic and fluoroscopic x-ray units

32 IBA Activities in a Nutshell MI-BR-E-MagicMax Rev Q.:500 IBA 2011 / All rights reserved IBA delivers solutions of unprecedented precision with a focus in the fields of cancer diagnosis and therapy. Diagnostics Portfolio Safer Imaging, Earlier Cancer Detection Advanced quality assurance devices for Medical Imaging: Solutions for x-ray diagnosis and patient-dose monitoring Unique expertise in the design of cyclotrons: Solutions for radiopharmaceutical tracers incl. production and distribution Radiation Therapy Portfolio Fighting Cancer Undisputed leader in Particle Therapy: enabling the most precise and effective radiation therapy Industry leading QA and dosimetry solutions: maximizing efficiency, minimizing errors, better outcomes Imaging fiducial markers: Visicoil enabling high precision tumor targeting Sterilization & Ionization Improving Hygiene and Safety of Everyday Life Electron accelerators and high power X-Ray solutions: applied in many industries to sterilize medical devices, to cold pasteurize food products or to improve polymer properties IBA, a Belgian company, is listed on the paneuropean stock exchange EURONEXT and its Annual Reports can be downloaded on the Website: Depicted product images may differ from the actual scope of delivery. Images and technical specifications are subject to change without prior notice. Contact details: info@iba-dosimetry.com Europe, Middle East, Africa IBA Dosimetry GmbH Bahnhofstr Schwarzenbruck, Germany Tel.: Fax: North America, Latin America IBA Dosimetry America 3150 Stage Post Drive, Suite 110 Bartlett, TN 38133, USA Tel.: Fax: Asia Pacific IBA Dosimetry Asia Pacific No.6, Xing Guang Er Jie Beijing OPTO-mechatronics Industrial Park (OIP), Tongzhou District Beijing , China Tel.: Fax: Distributed by:

33 MatriXX Evolution System The Solution for Rotational Treatment QA

34 Rotational therapy Rotational therapy techniques have shifted paradigms in terms of treatment efficiency and precision. Simultaneous modulation of gantry rotation speed, dose rate and MLC position at every gantry angle result in a highly accurate conformity of the dose delivery with greatly diminished treatment times. With this significant improvements, plans can now be tailored to each clinical case. With this increased dynamic, the need for fast and accurate dosimetric verification of planned vs. delivered doses as well as dedicated Linac QA is evident. Advanced treatment techniques require advanced Dosimetry solutions. 2 IBA DOSIMETRY ROTATIONAL QA

35 Maximize efficiency, minimize errors The fastest and most accurate way to validate your RapidArc, VMAT, Hi-Art or conventional IMRT treatment plan under exact treatment conditions. Easy set-up on the patient couch. MatriXX Evolution digital 2D Dosimetry: fastest sampling time, highest spatial resolution and lowest angular dependancy. Unique Plastic Water phantom for quick set-up and registration. Only one phantom needed throughout the entire process. Workflow driven efficiency in OmniPro-I mrt software. Gantry angle measurement for angular dependency optimization. 3 IBA DOSIMETRY ROTATIONAL QA

36 with software MatriXX Evolution is the optimized 2D digital verifi cation system for Rotational therapy techniques. It operates with the intuitive and user-friendly OmniPro-I mrt application software for complete plan verifi cation and QA of IMRT / IGRT / Rotational treatments: Air-vented pixel ionization chambers (~ 10 %). Parallel read-out of all ionization chambers without dead time. Down to 20 msec / sample. Highest spatial resolution: 1020 ionization chambers in an active area of 24 x 24 cm 2. Gantry angle sensor for: easy set-up on the gantry easy alignment indicated by the LEDs OmniPro-I mrt software platform: TPS import Visual comparison MatriXX Evolution and film measurement Mathematical analysis MatriXX was designed and built in cooperation with Torino University and INFN. 4 IBA DOSIMETRY ROTATIONAL QA

37 One, multiple configurations The MULTICube provides an efficient way to validate the dose under parameters mirroring those of the patient during treatment. The new MULTICube combined with MatriXX Evolution and OmniPro-I mrt software is the smart solution for all dynamic applications. The multiple configurations in 5 cm increments allow you to physically position the measurement plane of the MatriXX Evolution at a point in the phantom material that will resemble its position in the patient. The MULTICube enables you to position the MatriXX Evolution in different depths vertically by raising the measurement plane off the couch by up to 20 cm. Removable film cassette with registration points for independent film verification at same measurement plane as the MatriXX Evolution. 5 IBA DOSIMETRY ROTATIONAL QA

38 Speed, Accuracy, Versatility Speed Display of each frame as a function of the gantry angle Composite dose distribution measurement. Total delivery time 76 sec Accuracy MatriXX Evolution, highest reproducibility and accuracy of measurements Angular dependency optimized by the gantry angle measurement 6 IBA DOSIMETRY ROTATIONAL QA

39 Versatility: both patient and Linac QA Patient QA using MatriXX Evolution Measured (MatriXX) Profiles Planned (TPS) Analysis Linac QA using MatriXX Evolution Measured (MatriXX) Profiles Planned (TPS) Analysis 7 IBA DOSIMETRY ROTATIONAL QA

40 The workflow 4 simple steps towards treatment RapidArc, VMAT PLAN 2) Treatment plan is recalculated with chambers at isocenter distance; Dose Maps are calculated and information is exported to OmniPro-I mrt 1) CT of MatriXX Evolution with MULTICube and export to TPS Hi-Art 2) Treatment plan is recalculated with chambers at isocenter distance; Dose Maps are calculated and information is exported to OmniPro-I mrt 8 IBA DOSIMETRY ROTATIONAL QA

41 Accept: Patient ready to treat 3) Set-up and deliver plan to MatriXX Evolution and MULTICube 4) MatriXX Evolution data is compared to plan data using the palette of intuitive evaluation tools with OmniPro-I mrt Reject: Further evaluation is needed 4) MatriXX Evolution data is compared to plan data using the palette of intuitive evaluation tools with OmniPro-I mrt Accept: Patient ready to treat 3) Set-up and deliver plan to MatriXX Evolution and MULTICube Reject: Further evaluation is needed Export to DQA for analysis 9 IBA DOSIMETRY ROTATIONAL QA

42 Clinical proof RapidArc VMAT The introduction of a novel treatment delivery technique as RapidArc asks for effi cient and accurate methods to verify the calculated dose distributions. At the VU University medical center of Amsterdam, the Netherlands, we choose to perform the patient specifi c QA in arc-based plans with both fi lm dosimetry and with MatriXX Evolution measurements. In contrast to fi lm measurements, MatriXX Evolution measurements are displayed instantaneously and they provide a very fast way to verify the dose calculations. With the introduction of new techniques like RapidArc, it is important to have a fast method to measure the stability of plan delivery in time, for which the MatriXX Evolution is a suitable detector. We hope that in the future we can fully replace fi lm measurements with MatriXX Evolution dosimetry. Dr. Wilko Verbakel Medical Physicist, Dept of Radiation Oncology VU University Medical Center De Boelelaan 1117 NL-1081 HV Amsterdam VMAT is a very fast and effi cient treatment delivery technique and it is thus imperative to have a time effi cient QA tool. Verifi cation of composite treatment plans has been the preferred approach for patient specifi c IMRT verifi cation at the Department of Radiotherapy, Medical University Vienna/AKH Vienna since Using a similar approach for rotational high precision RT techniques was thus obvious to us. MatriXX Evolution allows to perform QA in a very effi cient manner and provides direct online and multidimensional information about dosimetric deviations. Assoc. Prof. Dietmar GEORG, Ph.D. Head, Div. Medical Radiation Physics Department of Radiotherapy Medical University Vienna / AKH Vienna Währinger Gürtel AT 1090 Vienna Hi-Art We have used the MatriXX Evolution at St. Agnes Cancer Center for approximately 1 year and have found it to provide accuracy that is similar to point ion chamber measurements while also being an acceptable alternative to fi lm for dose localization. In addition, the use of the MatriXX Evolution has reduced our IMRT plan verifi cation times by over 50% by eliminating the extra steps of fi lm processing and digitization, and the conversion of point ion chamber readings to obtain absolute dose. Timothy Holmes, PhD Director, Medical Physics/RSO St. Agnes Cancer Center 900 Caton Ave, Baltimore, MD USA IBA DOSIMETRY ROTATIONAL QA

43 Technical specifications MULTICube Size MULTICube: Approximate weight: Removable film cassette: Material: Size MULTICubeLite: Approximate weight: Removable film cassette: Material: 31.4 cm (L) x 34 cm (W)) x 34 cm (H) 33 kg 4.1 kg Plastic Water within 0.5% from 150 kev to 100 MeV of true water dose 31.4 cm (L) x 34 cm (W) x 22 cm (H) 19.8 kg 4.1 kg Plastic Water within 0.5% from 150 kev to 100 MeV of true water dose MatriXX Evolution Number of chambers: 1020 Active area: 24.4 x 24.4 cm 2 Sensor layout: matrix in a plane arranged in a 32 x 32 grid Pixel distance: 7.62 mm center-to-center Chamber type: vented pixel ionization chambers Chamber size: 4.5 (Ø) x 5 (h) mm, chamber volume 0.08 cm 3 Typical sensitivity: 0.42 nc/gy Effective point of measurement: 3 mm from surface Accuracy of angle sensor: +/- 0.6 Minimum computer requirements (OmniPro-I mrt) Operating system: Microsoft Windows (XP, VISTA * 32-bit) Processor: Pentium (or equivalent), 1.8 GHz or better Memory (RAM): 2 GB (recommended for real-time mode) Hard disk: with at least 160 MB available, recommended 40 GB for data archiving Monitor and graphics: supporting a resolution of 1024 x 768 pixel at True Colour (32-bit) Ports: available Ethernet connection (RJ-45 for I mrt MatriXX) interface to film scanner, USB 2.0 Import of planned data: CadPlan (dose / fluence), CMS (dose / fluence), BrainLAB (dose / fluence), Plato (dose), Pinnacle (fluence) and from all TPS that support DICOM RT or RTOG formats Technical data is subject to change without prior notice. TomoTherapy and TomoTherapy Hi-Art are trademarks of TomoTherapy Plastic Water is a trademark of CIRS RapidArc TM is a trademark of Varian Medical Systems Inc. * Some accessories might not be Microsoft Windows Vista TM compatible (e.g. Film scanner) 11 IBA DOSIMETRY ROTATIONAL QA

44 IBA Activities in a Nutshell IBA delivers solutions of unprecedented precision with a focus in the fields of cancer diagnosis and therapy. Diagnostics Portfolio Safer Imaging, Earlier Cancer Detection Advanced quality assurance devices for Medical Imaging: Solutions for x-ray diagnosis and patient-dose monitoring Unique expertise in the design of cyclotrons: Solutions for radiopharmaceutical tracers incl. production and distribution Radiation Therapy Portfolio Fighting Cancer Undisputed leader in Particle Therapy: enabling the most precise and effective radiation therapy Industry leading QA and dosimetry solutions: maximizing efficiency, minimizing errors, better outcomes Imaging fiducial markers: Visicoil enabling high precision tumor targeting Sterilization & Ionization Improving Hygiene and Safety of Everyday Life Electron accelerators and high power X-Ray solutions: applied in many industries to sterilize medical devices, to cold pasteurize food products or to improve polymer properties Contact details: info@iba-dosimetry.com Europe, Middle East, Africa IBA Dosimetry GmbH Bahnhofstr Schwarzenbruck, Germany Tel.: Fax: North America, Latin America IBA Dosimetry America 3150 Stage Post Drive, Suite 110 Bartlett, TN 38133, USA Tel.: Fax: Asia Pacific IBA Dosimetry Asia Pacific No.6, Xing Guang Er Jie Beijing OPTO-mechatronics Industrial Park (OIP), Tongzhou District Beijing , China Tel.: Fax: RT-BR-E-MatriXX Evolution Rev IBA 2011 / All rights reserved Manufacturer IBA Dosimetry GmbH IBA a Belgian company, is listed on the paneuropean stock exchange EURONEXT and its Annual Reports can be downloaded on the Website:

45 What You See Is What You Treat VISICOILTM

46 Next generation implantable linear tissue marker for high precision real-time Image Guidance Magnified image of VISICOIL * Usable with conformal RT, IMRT, IGRT and adaptive RT Visible under ultrasound, X-Ray, portal imaging, CT and MRI imaging Allows for accurate targeting when using a localized radiation field Helps reduce subjectivity of daily patient positioning Makes organ movement and deformation visible Designed to be stable and non-migrating in soft tissue Multiple lengths ensure differentiation of markers, thus making volume, size and orientation easy to determine Only 2 coils needed (compared to 3-5 conventional markers for the same accuracy) * patent pending 2 IBA DOSIMETRY VISICOIL

47 Flexible helical coil structure Conforms to highly mobile tissue as it changes shape, orientation and position Sterile, ready to use delivery systems Coil length used per implant site Coil Diameter 0.35 mm 0.75 mm 1.10 mm Needle carrier Enables easy, accurate placement and deployment Multiple lengths Available in three dedicated diameters (0.35 mm, 0.75 mm and 1.10 mm) as well as four lengths (0.5 cm, 1 cm, 2 cm and 3 cm) Visibility * 0.5 cm length not available for 0.35 version * Pre-loaded markers* Existing diameters: 0.35 mm, 0.75 mm, 1.10 mm Available in 17, 18 or 19G needles Unique design Less traumatic Fewer needle punctures Allows for placement in more delicate tumors Prostate 1 cm, 0.5 cm, 0.5 cm, 2 cm 1 cm, 2 cm 1 cm, 2 cm Breast* 0.5 cm, 0.5 cm, 1 cm 1 cm Lung* 1 cm, 0.5 cm, 0.5 cm, 2 cm, 1 cm, 2 cm, 1 cm, 2 cm, 3 cm 3 cm 3 cm Cervix* 0.5 cm, 1 cm, 2 cm Pancreas* 1 cm, 2 cm, 3 cm * Implantation techniques in organ sites other than prostate not currently validated by RadioMed. Coil lengths indicated are suggested lengths based on early clinical work. Specifiic coil length/diameter needs to be determined by the implanting physician. (0.75mm VISICOIL) TRUS BAT Visible under all common imaging modalities Ideal for image fusion Portal Imaging MRI CT X-Ray Recommended visualization techniques CT-Fluro-TRUS MRI Trans-Abdominal Ultrasound EPID-Portal KV, OBI MV 0.35 mm 0.75 mm 1.10 mm * CE marked 3 IBA DOSIMETRY VISICOIL

48 IBA Activities in a Nutshell IBA delivers solutions of unprecedented precision with a focus in the fields of cancer diagnosis and therapy. Diagnostics Portfolio Safer Imaging, Earlier Cancer Detection Advanced quality assurance devices for Medical Imaging: Solutions for x-ray diagnosis and patient-dose monitoring Unique expertise in the design of cyclotrons: Solutions for radiopharmaceutical tracers incl. production and distribution Radiation Therapy Portfolio Fighting Cancer Undisputed leader in Particle Therapy: enabling the most precise and effective radiation therapy Industry leading QA and dosimetry solutions: maximizing efficiency, minimizing errors, better outcomes Imaging fiducial markers: Visicoil enabling high precision tumor targeting Sterilization & Ionization Improving Hygiene and Safety of Everyday Life Electron accelerators and high power X-Ray solutions: applied in many industries to sterilize medical devices, to cold pasteurize food products or to improve polymer properties IBA a Belgian company, is listed on the paneuropean stock exchange EURONEXT and its Annual Reports can be downloaded on the Website: Contact details: info@iba-dosimetry.com Europe, Middle East, Africa IBA Dosimetry GmbH Bahnhofstr Schwarzenbruck, Germany Tel.: Fax: North America, Latin America IBA Dosimetry America 3150 Stage Post Drive, Suite 110 Bartlett, TN 38133, USA Tel.: Fax: Asia Pacific IBA Dosimetry Asia Pacific No.6, Xing Guang Er Jie Beijing OPTO-mechatronics Industrial Park (OIP), Tongzhou District Beijing , China Tel.: Fax: IM-BR-E-VISICOIL Rev IBA 2011 / All rights reserved VISICOIL is a trademark of IBA Dosimetry VISICOIL is manufactured by RadioMed, Inc.; 3150 Stage Post Drive, Suite 110, Bartlett, TN 38133, USA

Blue Phantom 2 with OmniPro-Accept (V 7) Fastest, Most Accurate and Most Reliable Solution for Relative Dosimetry

Blue Phantom 2 with OmniPro-Accept (V 7) Fastest, Most Accurate and Most Reliable Solution for Relative Dosimetry Blue Phantom 2 with OmniPro-Accept (V 7) Fastest, Most Accurate and Most Reliable Solution for Relative Dosimetry Relative Dosimetry Fastest, most Accurate and most Reliable For over 30 years IBA Dosimetry

More information

Blue Phantom 2 with. Built for the next generation. Introduction Introduction Introduction Introtro Intro Intro

Blue Phantom 2 with. Built for the next generation. Introduction Introduction Introduction Introtro Intro Intro Blue Phantom 2 with In OmniPro-Accept Vivo treatment (V verification 7) Built for the next generation Introduction Introduction Introduction Introtro Intro Intro The rapid development of advanced treatment

More information

Efficient Dosimetry for Proton Therapy

Efficient Dosimetry for Proton Therapy Efficient Dosimetry for Proton Therapy Why IBA Dosimetry? IBA Dosimetry offers the full product range tailored to fit any Proton Therapy QA needs. PT treatment safety, as well as most efficient dosimetry

More information

Your Global Quality Assurance Platform All-in-One. All Connected. All Secure.

Your Global Quality Assurance Platform All-in-One. All Connected. All Secure. Your Global Quality Assurance Platform All-in-One. All Connected. All Secure. www.iba-dosimetry.com Dealing with complexity in your QA? All-in-One. Linacs OK Patients OK Reports APPROVED Satellite Center

More information

Online Care, Online Control, Online Confidence

Online Care, Online Control, Online Confidence Online Care, Online Control, Online Confidence * Online Treatment Monitoring and much more! Designed for Efficiency provides you with online control and online confidence of treating your patients exactly

More information

Pre-treatment verification for IMRT / IGRT and Rotational therapy

Pre-treatment verification for IMRT / IGRT and Rotational therapy In OmniPro-I mrt Vivo treatment software verification Pre-treatment verification for IMRT / IGRT and Rotational therapy Introduction Introduction Introduction Introtro Intro Intro The rapid development

More information

Absolute Dosimetry. Versatile solid and water phantoms. Introduction Introduction Introduction Introtro Intro Intro

Absolute Dosimetry. Versatile solid and water phantoms. Introduction Introduction Introduction Introtro Intro Intro In Phantoms Vivo treatment for Absolute Dosimetry verification Versatile solid and water phantoms Introduction Introduction Introduction Introtro Intro Intro The rapid development of advanced treatment

More information

IBA Dosimetry Company Presentation. Patient Safety & Quality Control

IBA Dosimetry Company Presentation. Patient Safety & Quality Control IBA Dosimetry Company Presentation Patient Safety & Quality Control IBA Mission Protect, enhance and save lives Protect, Enhance, and Save Lives - 2 - The History of IBA Dosimetry A story of innovation

More information

iba-dosimetry.com INTEGRATED QUALITY ASSURANCE Solution Overview

iba-dosimetry.com INTEGRATED QUALITY ASSURANCE Solution Overview iba-dosimetry.com Solution Overview 2 3 IBA DOSIMETRY WHY? Protect, Enhance and Save Lives At IBA we share ideas and know-how with our customers and partners to provide innovative solutions for the diagnosis

More information

See it! Trust it! Treat it!

See it! Trust it! Treat it! Flexible soft tissue Marker for IGRT, SBRT & PT See it! Trust it! Treat it! THORACIC GI GU CERVIX See it! Improved Marker Visibility by Design Conventional gold seeds VISICOIL linear fiducial marker 1)

More information

Unrivaled, End-to-End

Unrivaled, End-to-End PHANTOMS Unrivaled, End-to-End Stereotactic QA Industry-leading 0.1mm accuracy minimizes errors at each link in the stereotactic quality assurance chain. Stereotactic radiosurgery (SRS) is governed by

More information

IMAGE-GUIDED RADIATION THERAPY

IMAGE-GUIDED RADIATION THERAPY IMAGE-GUIDED RADIATION THERAPY Your Single Source Oncology Solutions Provider Plan. Target. Treat. At Best NOMOS, we design products and solutions that help medical professionals treat a variety of cancers.

More information

Volumetric Modulated Arc Therapy - Patient Specific QA

Volumetric Modulated Arc Therapy - Patient Specific QA Volumetric Modulated Arc Therapy - Patient Specific QA Daliang Cao, PhD, DABR Swedish Cancer Institute, Seattle, WA VMAT plan QA methods Composite dose measurement Film & ion chamber diode array Mapcheck

More information

Elekta Synergy Digital accelerator for advanced IGRT

Elekta Synergy Digital accelerator for advanced IGRT Elekta Synergy Digital accelerator for advanced IGRT Setting the standard for confident care The Field of Radiation Therapy is Constantly Changing Being able to take full advantage of the latest clinical

More information

Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance

Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 3, 2015 Evaluation of Dosimetry Check software for IMRT patient-specific quality assurance Ganesh Narayanasamy, Travis Zalman, Chul S. Ha,

More information

Amendment No. 2. Item No. 2 (Rfx/ Event number )

Amendment No. 2. Item No. 2 (Rfx/ Event number ) Amendment 2 Sub: Amendment to the Document 06.12.2018 Ref.: Notice Inviting Bid ref. HITES/PCD/NCI-AIIMS/36/18-19 dated 26.09.2018 read with its Amendment no. 1 dated 19.11.18 The following changes have

More information

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St.

Quality Assurance of Ultrasound Imaging in Radiation Therapy. Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St. Quality Assurance of Ultrasound Imaging in Radiation Therapy Zuofeng Li, D.Sc. Murty S. Goddu, Ph.D. Washington University St. Louis, Missouri Typical Applications of Ultrasound Imaging in Radiation Therapy

More information

Elekta Infinity Digital accelerator for advanced treatments

Elekta Infinity Digital accelerator for advanced treatments Elekta Infinity Digital accelerator for advanced treatments Redefining treatment precision, speed and control Confidence to increase conformance and speed without compromising target coverage Set yourself

More information

Elekta Infinity. Digital accelerator for advanced treatments. Redefining treatment precision, speed and control

Elekta Infinity. Digital accelerator for advanced treatments. Redefining treatment precision, speed and control Elekta Infinity Digital accelerator for advanced treatments Redefining treatment precision, speed and control Do you have the confidence to increase conformance and speed without compromising target coverage?

More information

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry DETECTORS Always perfectly oriented. Semiflex 3D 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry The New Reference Class Full 3D Geometry For FFF and FF Beams Semiflex 3D 3D Detector

More information

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry

Semiflex 3D. Always perfectly oriented. 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry DETECTORS Always perfectly oriented. Semiflex 3D 3D Thimble Ionization Chamber for Relative and Absolute Dosimetry The New Reference Class Full 3D Geometry For FFF and FF Beams Semiflex 3D 3D Detector

More information

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications

Varian Treatment. Streamlined Treatment Delivery Management Application. Specifications Varian Treatment Streamlined Treatment Delivery Management Application Specifications Specifications Varian Treatment 1 Introduction Streamlined Treatment Delivery Management Varian Treatment verifies

More information

RaySafe X2 Solo DENT. X-ray meter for dental applications

RaySafe X2 Solo DENT. X-ray meter for dental applications RaySafe X2 Solo DENT X-ray meter for dental applications Quality Assurance in Dental X-ray Hundreds of millions of X-ray exposures are done every year in dental clinics around the globe. The majority are

More information

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA

CHAPTER 5. STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA CHAPTER 5 STUDY OF ANGULAR RESPONSE OF asi 1000 EPID AND IMATRIXX 2-D ARRAY SYSTEM FOR IMRT PATIENT SPECIFIC QA 5.1 Introduction With the advent of new techniques like intensity modulated radiotherapy

More information

EORTC Member Facility Questionnaire

EORTC Member Facility Questionnaire Page 1 of 9 EORTC Member Facility Questionnaire I. Administrative Data Name of person submitting this questionnaire Email address Function Phone Institution Address City Post code Country EORTC No Enter

More information

Leila E. A. Nichol Royal Surrey County Hospital

Leila E. A. Nichol Royal Surrey County Hospital 2 nd UK and Ireland Dosimetry Check User Meeting Symposium Clatterbridge Cancer Centre, 24 th October 2012 Leila E. A. Nichol Royal Surrey County Hospital Leila.Nichol@nhs.net *My experience with Dosimetry

More information

Introduction. Modalities used in imaging guidance. Flat panel detector. X-ray Imaging Dose to Patients in the Era of Image-Guided Radiation Therapy

Introduction. Modalities used in imaging guidance. Flat panel detector. X-ray Imaging Dose to Patients in the Era of Image-Guided Radiation Therapy X-ray Imaging Dose to Patients in the Era of Image-Guided Radiation Therapy George Ding, Ron Price, Charles Coffey Vanderbilt-Ingram Cancer Center Vanderbilt University Medical Center, Nashville, TN Introduction

More information

Ingenia MR-RT. MR Systems. The comprehensive MR-sim solution to fit your planning

Ingenia MR-RT. MR Systems. The comprehensive MR-sim solution to fit your planning Ingenia MR-RT MR Systems The comprehensive MR-sim solution to fit your planning Table of contents Experience the difference MRI makes 3 A comprehensive MR-sim solution 4 Position with precision 6 Tailored

More information

ph fax

ph fax This product is available through: JRT Associates www.standardimaging.com 800-261-4446. ph 608-831-0025. fax 608-831-2202 5 Nepperhan Avenue, Suite 2B 3120 Deming Way Middleton WIElmsford, 53562-1461 NY

More information

Elekta - a partner and world-leading supplier

Elekta - a partner and world-leading supplier Experience Elekta Elekta - a partner and world-leading supplier of clinical solutions for image guided radiation therapy, stereotactic radiotherapy, radiosurgery and brachytherapy, as well as advanced

More information

Solutions at GE Inspection Technologies

Solutions at GE Inspection Technologies Solutions at GE Inspection Technologies Business Overview Paul A. Meyer Our Company A global leader in technology-driven inspection solutions that deliver productivity, quality, and safety to our customers

More information

IMRT QUESTIONNAIRE. Address: Physicist: Research Associate: Dosimetrist: Responsible Radiation Oncologist(s)

IMRT QUESTIONNAIRE. Address: Physicist:   Research Associate:   Dosimetrist:   Responsible Radiation Oncologist(s) IMRT QUESTIONNAIRE Institution: Date: / / Address: Physicist: e-mail: Telephone: Fax: Research Associate: email: Telephone: Fax: Dosimetrist: email: Telephone: Fax: Responsible Radiation Oncologist(s)

More information

Implementation of advanced RT Techniques

Implementation of advanced RT Techniques Implementation of advanced RT Techniques Tibor Major, PhD National Institute of Oncology Budapest, Hungary 2. Kongres radiološke tehnologije, Vukovar, 23-25. September 2016. Current RT equipments at NIO,

More information

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS

STEREOTACTIC DOSE VERIFICATION PHANTOM VERSATILE STEREOTACTIC QA PHANTOMS PHANTOMS VERSATILE STEREOTACTIC QA For fast and accurate commissioning of Accuray CyberKnife treatment systems and patient specific dose verification plans STEREOTACTIC DOSE VERIFICATION PHANTOM Stereotactic

More information

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer? Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer? Dimos Baltas Dept. of Medical Physics & Engineering, Strahlenklinik, Klinikum Offenbach GmbH 63069 Offenbach, Germany

More information

Digital mammography imaging from Carestream Health solutions for great workflow, productivity, and patient care.

Digital mammography imaging from Carestream Health solutions for great workflow, productivity, and patient care. Digital Mammography Imaging on KODAK CR Systems Digital mammography imaging from Carestream Health solutions for great workflow, productivity, and patient care. Commercial distribution of the CR Mammography

More information

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015

IROC Liver Phantom. Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015 IROC Liver Phantom Guidelines for Planning and Irradiating the IROC Liver Phantom. Revised July 2015 The study groups are requests that each institution keep the phantom for no more than 2 weeks. During

More information

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy

Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy Implementing New Technologies for Stereotactic Radiosurgery and Stereotactic Body Radiation Therapy Implementation of radiosurgery and SBRT requires a fundamentally sound approach Errors don t blur out

More information

IROC Head and Neck Phantom. Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised MARCH 2014

IROC Head and Neck Phantom. Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised MARCH 2014 IROC Head and Neck Phantom Guidelines for Planning and Irradiating the IROC IMRT Phantom. Revised MARCH 2014 The study groups are requesting that each institution keep the phantom for a period of time

More information

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR

Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR Linac or Non-Linac Demystifying And Decoding The Physics Of SBRT/SABR PhD, FAAPM, FACR, FASTRO Department of Radiation Oncology Indiana University School of Medicine Indianapolis, IN, USA Indra J. Das,

More information

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM *

A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM * Romanian Reports in Physics, Vol. 66, No. 2, P. 394 400, 2014 A TREATMENT PLANNING STUDY COMPARING VMAT WITH 3D CONFORMAL RADIOTHERAPY FOR PROSTATE CANCER USING PINNACLE PLANNING SYSTEM * D. ADAM 1,2,

More information

Automated Plan Quality Check with Scripting. Rajesh Gutti, Ph.D. Clinical Medical Physicist

Automated Plan Quality Check with Scripting. Rajesh Gutti, Ph.D. Clinical Medical Physicist Automated Plan Quality Check with Scripting Rajesh Gutti, Ph.D. Clinical Medical Physicist Veera.Gutti@BSWHealth.org Outline Introduction - BSW Automation in Treatment planning Eclipse Scripting API Script

More information

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program?

Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program? Are Transmission Detectors a Necessary Tool for a Safe Patient Radiation Therapy Program? Can you currently use direct documentation and measurement of delivered dose to ensure you did not underdose or

More information

Radiation Oncology. The conf ident path to treatment Philips Radiation Oncology Solutions

Radiation Oncology. The conf ident path to treatment Philips Radiation Oncology Solutions Radiation Oncology The conf ident path to treatment Philips Radiation Oncology Solutions The confident path to treatment Philips Radiation Oncology Solutions Imaging Image registration Contouring Treatment

More information

Patient and Linac QA - present and the future

Patient and Linac QA - present and the future Patient and Linac QA - present and the future IBA Dosimetry Sandra Kos Service Department Customer Support Specialist sandra.kos@iba-group.com 1 IBA Dosimetry Part of IBA Group OUR MISSION At IBA we dare

More information

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification

Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 11, NUMBER 2, SPRING 2010 Dosimetric study of 2D ion chamber array matrix for the modern radiotherapy treatment verification Sathiyan Saminathan, a Ravikumar

More information

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation

8/2/2018. Disclosure. Online MR-IG-ART Dosimetry and Dose Accumulation Online MR-IG-ART Dosimetry and Dose Accumulation Deshan Yang, PhD, Associate Professor Department of Radiation Oncology, School of Medicine Washington University in Saint Louis 1 Disclosure Received research

More information

I. Equipments for external beam radiotherapy

I. Equipments for external beam radiotherapy I. Equipments for external beam radiotherapy 5 linear accelerators (LINACs): Varian TrueBeam 6, 10 & 18 MV photons, 6-18 MeV electrons, image-guided (IGRT) and intensity modulated radiotherapy (IMRT),

More information

iviewdose Confidence and assurance in dose delivery

iviewdose Confidence and assurance in dose delivery iviewdose Confidence and assurance in dose delivery As radiotherapy techniques advance and treatment plans become more complex, involving escalated doses and increasingly conformal deliveries, the need

More information

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT

Normal tissue doses from MV image-guided radiation therapy (IGRT) using orthogonal MV and MV-CBCT Received: 28 September 2017 Revised: 17 November 2017 Accepted: 28 December 2017 DOI: 10.1002/acm2.12276 RADIATION ONCOLOGY PHYSICS Normal tissue doses from MV image-guided radiation therapy (IGRT) using

More information

Clinical Precision for Best Cancer Care. Dee Mathieson Senior Vice President Oncology Business Line Management

Clinical Precision for Best Cancer Care. Dee Mathieson Senior Vice President Oncology Business Line Management Clinical Precision for Best Cancer Care Dee Mathieson Senior Vice President Oncology Business Line Management Optimizing clinical results Key drivers in modern Radiation Therapy Clinical precision Continuous

More information

SunCHECK Patient Comprehensive Patient QA

SunCHECK Patient Comprehensive Patient QA The SunCHECK Platform SunCHECK Patient Comprehensive Patient QA SunCHECK Patient // Comprehensive Patient QA Automate Your Patient QA SunCHECK Patient automates all your Patient QA needs from Secondary

More information

MVCT Image. Robert Staton, PhD DABR. MD Anderson Cancer Center Orlando. ACMP Annual Meeting 2011

MVCT Image. Robert Staton, PhD DABR. MD Anderson Cancer Center Orlando. ACMP Annual Meeting 2011 MVCT Image Guidance and QA Robert Staton, PhD DABR MD Anderson Cancer Center Orlando ACMP Annual Meeting 2011 Disclosures MDACCO has received grant funding from TomoTherapy, Inc. Overview TomoTherapy MVCT

More information

A model for assessing VMAT pre-treatment verification systems and VMAT optimization algorithms

A model for assessing VMAT pre-treatment verification systems and VMAT optimization algorithms 1 st Workshop: Radiotherapy Modelling - Luz Saint Sauveur, Sep 2016 A model for assessing VMAT pre-treatment verification systems and VMAT optimization algorithms A R Barbeiro 1, A Ureba 2, J A Baeza 3,

More information

D DAVID PUBLISHING. Uncertainties of in vivo Dosimetry Using Semiconductors. I. Introduction. 2. Methodology

D DAVID PUBLISHING. Uncertainties of in vivo Dosimetry Using Semiconductors. I. Introduction. 2. Methodology Journal of Life Sciences 9 (2015) 120-126 doi: 10.17265/1934-7391/2015.03.005 D DAVID PUBLISHING Uncertainties of in vivo Dosimetry Using Semiconductors Zeina Al Kattar, Hanna El Balaa and Saeed Zahran

More information

Assessment of a three-dimensional (3D) water scanning system for beam commissioning and measurements on a helical tomotherapy unit

Assessment of a three-dimensional (3D) water scanning system for beam commissioning and measurements on a helical tomotherapy unit JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 1, 2015 Assessment of a three-dimensional (3D) water scanning system for beam commissioning and measurements on a helical tomotherapy unit

More information

SpiderX. Portable Residual Stress X-Ray Diffractometer.

SpiderX. Portable Residual Stress X-Ray Diffractometer. Portable Residual Stress X-Ray Diffractometer www.gnr.it About SpiderX GNR Analytical Instrument offers equipment based on X-Ray Diffraction to measure residual stress state and retained austenite content.

More information

Herlev radiation oncology team explains what MRI can bring

Herlev radiation oncology team explains what MRI can bring Publication for the Philips MRI Community Issue 46 2012/2 Herlev radiation oncology team explains what MRI can bring The radiotherapy unit at Herlev University Hospital investigates use of MRI for radiotherapy

More information

Dosisverifikation mit Delta 4 Discover während der Behandlung

Dosisverifikation mit Delta 4 Discover während der Behandlung Dosisverifikation mit Delta 4 Discover während der Behandlung Anders Adolfson, Regional Sales Manager at Scandidos AK IMRT 2015 in Erlangen, March 19 th 2015 Agenda Which problem does Delta 4 Discover

More information

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction

AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction AAPM Task Group 180 Image Guidance Doses Delivered During Radiotherapy: Quantification, Management, and Reduction Parham Alaei, Ph.D. Department of Radiation Oncology University of Minnesota NCCAAPM Fall

More information

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014

Lung Spine Phantom. Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014 Lung Spine Phantom Guidelines for Planning and Irradiating the IROC Spine Phantom. MARCH 2014 The study groups are requesting that each institution keep the phantom for no more than 2 week. During this

More information

MRI to fit your planning. Philips Panorama HFO Oncology Configuration

MRI to fit your planning. Philips Panorama HFO Oncology Configuration MRI to fit your planning Philips Panorama HFO Oncology Configuration MR Imaging that fits Philips Panorama HFO Oncology Configuration allows radiation oncologists to take full advantage of MRI s excellent

More information

Small field diode dosimetry

Small field diode dosimetry Small field diode dosimetry Parham Alaei, Ph.D. Department of Radiation Oncology University of Minnesota NCCAAPM Symposium-October 10, 2013 1 Diodes as beam data collection detectors Diodes as in vivo

More information

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou.

Technical Study. Institution University of Texas Health San Antonio. Location San Antonio, Texas. Medical Staff. Daniel Saenz. Niko Papanikolaou. Technical Study Stereotactic Radiosurgery with Elekta Versa HD and Monaco Accuracy of a single isocenter, multiple brain metastases VMAT plan delivered to a pseudo-patient dosimetric gel phantom Institution

More information

Welcome to a better way for YOU and YOUR patient.

Welcome to a better way for YOU and YOUR patient. Welcome to a better way for YOU and YOUR patient. The Next Generation of Prostate Care from Invivo Current methods of prostate cancer screening, such as prostate-specifi c antigen (PSA) tests and digital

More information

A new geometric and mechanical verification device for medical LINACs

A new geometric and mechanical verification device for medical LINACs JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 3, NUMBER 2, SPRING 2002 A new geometric and mechanical verification device for medical LINACs Keith T. Welsh,* Robert A. Wlodarczyk, and L. E. Reinstein

More information

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography

RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY. L19: Optimization of Protection in Mammography IAEA Training Material on Radiation Protection in Diagnostic and Interventional Radiology RADIATION PROTECTION IN DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY L19: Optimization of Protection in Mammography

More information

For true visualisation

For true visualisation ENGLISH For true visualisation Planmeca ProModel is a patient-specific physical model for high-end maxillofacial operations and dental surgery. By reproducing the anatomy of the patient in real-size, Planmeca

More information

ABAS Atlas-based Autosegmentation

ABAS Atlas-based Autosegmentation ABAS Atlas-based Autosegmentation Raising contouring to the next level Simultaneous Truth and Performance Level Estimation (STAPLE) Unique to ABAS, the STAPLE calculation is more robust than simple averaging.

More information

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4

Practical Reference Dosimetry Course April 2015 PRDC Program, at a glance. Version 1.0. Day 1 Day 2 Day 3 Day 4 Practical Reference Dosimetry Course 21-24 April 2015 PRDC 2015 Program, at a glance Version 1.0 Day 1 Day 2 Day 3 Day 4 Quantities and Units Free air chambers Uncertainties Brachytherapy traceability

More information

Delivering Top Performance. Outstanding Value. Exceptional Reliability. ACUSON X150 Ultrasound System. Answers for life.

Delivering Top Performance. Outstanding Value. Exceptional Reliability. ACUSON X150 Ultrasound System. Answers for life. Delivering Top Performance. Outstanding Value. Exceptional Reliability. ACUSON X150 Ultrasound System Answers for life. Gynecology Imaging Ovarian Follicles Abdominal Imaging Renal Vasculature, Color Doppler

More information

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past.

Disclosure. Outline. Machine Overview. I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past. Clinical Implementation of the CyberKnife Disclosure I have received honoraria from Accuray in the past. I have had travel expenses paid by Accuray in the past. Mary Ellen Masterson-McGary McGary CyberKnife

More information

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM *

A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM * Romanian Reports in Physics, Vol. 66, No. 2, P. 401 410, 2014 A VMAT PLANNING SOLUTION FOR NECK CANCER PATIENTS USING THE PINNACLE 3 PLANNING SYSTEM * M. D. SUDITU 1,2, D. ADAM 1,2, R. POPA 1,2, V. CIOCALTEI

More information

Mammography. Background and Perspective. Mammography Evolution. Background and Perspective. T.R. Nelson, Ph.D. x41433

Mammography. Background and Perspective. Mammography Evolution. Background and Perspective. T.R. Nelson, Ph.D. x41433 - 2015 Background and Perspective 2005 (in US) Women Men Mammography Invasive Breast Cancer Diagnosed 211,240 1,690 Noninvasive Breast Cancer Diagnosed 58,940 Deaths from Breast Cancer 40,410 460 T.R.

More information

Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive

Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive Captus 3000 Thyroid Uptake And Well System The Ultimate... User Friendly... Intuitive Performing Thyroid Uptake measurements has never been easier. The Captus 3000 combines a software program with the

More information

Dedicated to Mammography

Dedicated to Mammography ENGLISH True Dedication As the number of women diagnosed with breast cancer increases every year, more women are surviving cancer and are able to carry on living their everyday lives. Thanks to screening

More information

SRS Uncertainty: Linac and CyberKnife Uncertainties

SRS Uncertainty: Linac and CyberKnife Uncertainties SRS Uncertainty: Linac and CyberKnife Uncertainties Sonja Dieterich, PhD Linac/CyberKnife Technological Uncertainties 1 Linac Mechanical/Radiation Isocenters Depuydt, Tom, et al. "Computer aided analysis

More information

MAX-HD SRS PHANTOM THE COMPREHENSIVE END-TO-END SRS PHANTOM SCAN PLAN LOCALIZE TREAT. distributed by:

MAX-HD SRS PHANTOM THE COMPREHENSIVE END-TO-END SRS PHANTOM SCAN PLAN LOCALIZE TREAT. distributed by: SRS PHANTOM SCAN PLAN LOCALIZE TREAT THE COMPREHENSIVE END-TO-END SRS PHANTOM distributed by: Tel: +33 (0) 42 88 68 41 info@orion-france.com www.orion-france.com 2, Avenue du General Balfourier 75016 Paris,

More information

Dental Line. 3D digital panoramic system. radiology ahead

Dental Line. 3D digital panoramic system. radiology ahead Dental Line 3D digital panoramic system radiology ahead new generation 3D digital panoramic unit 3D imaging s value available for anyone Following the incredible success of the innovative digital panoramic

More information

Advanced in vitro exposure systems

Advanced in vitro exposure systems Advanced in vitro exposure systems VITROCELL VC 1/7 SMOKING MACHINE Features for e-cigarettes VITROCELL VC 1/7 SMOKING MACHINE Linear smoking machine with high tech features square puff profiles higher

More information

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy

Can we hit the target? Can we put the dose where we want it? Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy Quality Assurance in Stereotactic Radiosurgery and Fractionated Stereotactic Radiotherapy David Shepard, Ph.D. Swedish Cancer Institute Seattle, WA Timothy D. Solberg, Ph.D. University of Texas Southwestern

More information

IROC Prostate Phantom. Guidelines for Planning and Treating the IROC IMRT Prostate Phantom. Revised March 2014

IROC Prostate Phantom. Guidelines for Planning and Treating the IROC IMRT Prostate Phantom. Revised March 2014 IROC Prostate Phantom Guidelines for Planning and Treating the IROC IMRT Prostate Phantom. Revised March 2014 The study groups are requesting that each institution keep the phantom for a period of time

More information

DELIVERED PATIENT DOSE

DELIVERED PATIENT DOSE SOFTWARE DELIVERED PATIENT DOSE The only software that provides a true picture of patient and dose at each stage of treatment. Adaptivo patient dosimetry software does something other patient dosimetry

More information

Varian Acuity BrachyTherapy Suite One Room Integrated Image-Guided Brachytherapy

Varian Acuity BrachyTherapy Suite One Room Integrated Image-Guided Brachytherapy Varian Acuity BrachyTherapy Suite One Room Integrated Image-Guided Brachytherapy The Acuity BrachyTherapy Suite Integrating Imaging, Planning, and Treatment in a Single Room Each component draws on the

More information

IMRT QA: Point Dose Measurements or 2D Array?

IMRT QA: Point Dose Measurements or 2D Array? QA for IMRT IMRT QA: Point Dose Measurements or D Array? General Linac QA for IMRT MLC checks Dose linearity at low MU Patient-specific measurements Performed using various methods Purpose is to verify

More information

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases

Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases Evaluation of Monaco treatment planning system for hypofractionated stereotactic volumetric arc radiotherapy of multiple brain metastases CASE STUDY Institution: Odette Cancer Centre Location: Sunnybrook

More information

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D.

Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, Pamela Myers, Ph.D. Spatially Fractionated Radiation Therapy: GRID Sponsored by.decimal Friday, August 22, 2014 Pamela Myers, Ph.D. Introduction o o o o o Outline GRID compensator Purpose of SFRT/GRID therapy Fractionation

More information

Mass Spectrometry Made Simple for Clinical Diagnostic Labs

Mass Spectrometry Made Simple for Clinical Diagnostic Labs Mass Spectrometry Made Simple for Clinical Diagnostic Labs The SCIEX Topaz System with FDA-Cleared Topaz Vitamin D 200M Assay Kit Mass Spectrometry Made Simple SCIEX Topaz System for Clinical Diagnostics

More information

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device

Titan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device Titan power The best just got better Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device Let your equipment and needs interact The first and only one of its kind 4

More information

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer?

Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer? Can we deliver the dose distribution we plan in HDR-Brachytherapy of Prostate Cancer? Dimos Baltas 1,3, Natasa Milickovic 1, Nikolaos Zamboglou 2 1 Dept. of Medical Physics & Engineering, 2 Strahlenklinik,

More information

Welcome to a better way for

Welcome to a better way for Welcome to a better way for The Next Generation of Prostate Care from Invivo biopsy standard, commonly suffers from poor image resolution, and the biopsy needle often passes through tumor-free areas of

More information

GE Healthcare. LOGIQ E9 XDclear 2.0. Complete Ultrasound HEAD TO TOE OBESE TO THIN NEONATE TO GERIATRIC

GE Healthcare. LOGIQ E9 XDclear 2.0. Complete Ultrasound HEAD TO TOE OBESE TO THIN NEONATE TO GERIATRIC GE Healthcare LOGIQ E9 XDclear 2.0 Complete Ultrasound HEAD TO TOE OBESE TO THIN NEONATE TO GERIATRIC In addition to extraordinary image quality, the system has been further enhanced to meet the needs

More information

Head to new heights with your imaging SCANORA 3D

Head to new heights with your imaging SCANORA 3D SCANORA 3D Head to new heights with your imaging Benefits at a glance The solution for dentomaxillofacial and ENT imaging Easy Patient seated for added stability during exposure. Clear, self-explinatory

More information

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES

SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES SHIELDING TECHNIQUES FOR CURRENT RADIATION THERAPY MODALITIES MELISSA C. MARTIN, M.S., FACR, FAAPM PRESIDENT AAPM - 2017 PRESIDENT - THERAPY PHYSICS INC., GARDENA, CA MELISSA@THERAPYPHYSICS.COM AAPM Spring

More information

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies

Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies Intensity Modulated Radiation Therapy: Dosimetric Aspects & Commissioning Strategies ICPT School on Medical Physics for Radiation Therapy Justus Adamson PhD Assistant Professor Department of Radiation

More information

SUPERIORITY OF A REAL TIME PLANNING TECHNIQUE OVER IMAGE GUIDED RADIATION THERAPY FOR THE TREATMENT OF PRIMARY PROSTATE CANCERS

SUPERIORITY OF A REAL TIME PLANNING TECHNIQUE OVER IMAGE GUIDED RADIATION THERAPY FOR THE TREATMENT OF PRIMARY PROSTATE CANCERS SUPERIORITY OF A REAL TIME PLANNING TECHNIQUE OVER IMAGE GUIDED RADIATION THERAPY FOR THE TREATMENT OF PRIMARY PROSTATE CANCERS Authors: Scott Merrick James Wong MD, Mona Karim MD, Yana Goldberg MD DISCLOSURE

More information

Completion of Treatment Planning. Eugene Lief, Ph.D. Christ Hospital Jersey City, New Jersey USA

Completion of Treatment Planning. Eugene Lief, Ph.D. Christ Hospital Jersey City, New Jersey USA Completion of Treatment Planning Eugene Lief, Ph.D. Christ Hospital Jersey City, New Jersey USA Outline Entering Prescription Plan Printout Print and Transfer DRR Segment BEV Export to R&V Physician approval

More information

Mobile radiography realizes its full potential

Mobile radiography realizes its full potential Mobile radiography realizes its full potential Integrated, wireless workflows increase mobile radiography s contribution to patient care Who/where Radiology Department, Galway Clinic Doughiska, Galway,

More information

CyBio Felix Your Automated Application Starts Here

CyBio Felix Your Automated Application Starts Here Title Label Lab Automation CyBio Felix Your Automated Application Starts Here 2 CyBio FeliX Future-Proof Liquid Handling Automation Transform your manual workflows to automated processes on your benchtop!

More information

ARCCHECK: COMPREHENSIVE EVALUATION OF THE DIODE ARRAY PHANTOM - RULES OF THUMB FOR PHANTOM USE FOR QA. By Vibha Chaswal, Ph.D.

ARCCHECK: COMPREHENSIVE EVALUATION OF THE DIODE ARRAY PHANTOM - RULES OF THUMB FOR PHANTOM USE FOR QA. By Vibha Chaswal, Ph.D. ARCCHECK: COMPREHENSIVE EVALUATION OF THE DIODE ARRAY PHANTOM - RULES OF THUMB FOR PHANTOM USE FOR QA By Vibha Chaswal, Ph.D. ACKNOWLEDGEMENT Dr. Nilendu Gupta, Dr. Arnab Chakrabarti Dr. Yi Rong, Michael

More information