Sensitive, Accurate and Precise. MS Solutions Through SGE Products. Diamond MS Syringes evol XR MEPS SilTite FingerTite GC Capillary Columns

Size: px
Start display at page:

Download "Sensitive, Accurate and Precise. MS Solutions Through SGE Products. Diamond MS Syringes evol XR MEPS SilTite FingerTite GC Capillary Columns"

Transcription

1 Sensitive, Accurate and Precise MS Solutions Through SGE Products Diamond MS Syringes evol XR MEPS SilTite FingerTite GC Capillary Columns AUSTRALIA & PACIFIC REGION EUROPE JAPAN USA

2 Introduction Bringing you a range of products to suit your MS analyses, SGE provides the highest quality syringes, ferrules and columns. Diamond MS Syringes The Choice for Sensitivity Improve the sensitivity of your MS analysis: Lowest syringe carryover Reduced non specific sample interaction and increased analyte recovery Ultra smooth removable needles with choice of surface treatment Direct MS Infusion Rapid and Sensitive Sample Preparation, Direct Infusion into ESI MS Coupling MEPS technology with a digitally controlled analytical syringe, evol MEPS semi-automates sample preparation from extraction through to analysis. SilTite FingerTite The Smart Alternative The next generation ferrule system for gas chromatography systems delivering an easy, leak free installation for capillary columns without the use of any tools. GC Capillary Column Range The High Five The complete polysilphenylene and polycarborane GC column range New BP5MS optimized silphenylene column Five selectivities to suit your analyses

3 Diamond MS Syringes The Choice for Sensitivity Improve the sensitivity of your MS analysis: Lowest syringe carryover Reduced non specific sample interaction and increased analyte recovery Ultra smooth removable needles with choice of surface treatment We understand how important your MS results are, and how precious your sample is, so we engineered new syringes and needles to bring you the Diamond MS Syringe range. Diamond MS syringes and needles are MS ready and designed to improve the sensitivity of your MS results. Lowest Syringe Carryover The unique design of Diamond MS syringes and removable needles ensures carryover is reduced to levels lower even than the best fixed needle syringes available. In the event of needle damage, Diamond MS needles provide a cost effective alternative to purchasing an entire fixed needle syringe. Diamond MS syringes have unbeatable cleanability thereby further reducing carryover. Diamond MS Syringe Design SilTite metal ferrule for zero adhesive and zero interaction Specialized seal eliminates dead volume Clear visibility of plunger at zero position Color coded needle design Precise needle alignment for 0% sample transfer Reduce Non-Specific Interaction and Increase Sample Recovery Anything in the sample flowpath can interact with your sample and impact your results, so SGE has developed Ultra Smooth needles to reduce non specific interaction between your sample and the needle. 3 Ultra Smooth needles available for you to choose based on your sample properties: Ultra Smooth Ultra Smooth with Hydrophilic Treamtment Ultra Smooth with Hydrophobic Treatment To reduce non specific sample interaction even further, there are two needle treatment options available to avoid sample interactions due to hydrophilicity and hydrophobicity.

4 Reduce Non-Specific Interaction and Increase Sample Recovery Number of peaks above,000 counts ( LOG scale ) Conventional Syringe Reduced Non -Specific Interaction / Carryover Diamond MS syringe with Ultra Smooth Hydrophilic Coated Needle Diamond MS syringe with Ultra Smooth Needle Diamond MS syringe with Ultra Smooth Hydrophobic Coated Needle Clean syringes were washed 6 times with neat methanol, each wash was collected. Samples were then placed in an Eksigent Tempo LC system and the loading pump (50% methanol/0.1% Formic acid/water) used to infuse (initial flow of 2 µl/min then reduced to 0.5 µl/min for analysis) via a nanospray III ion source into an AB Sciex QTRAP Spectra were collected for a positive EMS scan of 0-00 amu. Diamond MS syringes are 0 times more sensitive than a conventional syringe. The Choice for Sensitivity How to choose your MS ready syringe and needle for improved sensitivity: 1. Choose a manual syringe or one specifically designed for your instrument 2. Select the syringe capacity 3. Choose the needle geometry LC or GC injections, tip design and needle dimensions 4. Choose which 'Ultra Smooth' needle best suits your application SYRINGES All syringes have a PTFE Plunger Tip Part Number Volume (ul) Manual Syringes Agilent Autosampler Syringes Shimadzu Autosampler Syringe CTC PAL Autosampler Syringes Thermo RSH Autosampler Syringes For more information on this product visit

5 Direct MS Infusion Rapid and Sensitive Source Analyzer Multiplier MS Infusion evol and µspe Use evol where ever you would use a syringe or syringe pump - preparation of standards, precise dispensing, dilution, injection, titration, sample preparation, MEPS (micro SPE) AND... direct MS infusion. Comparative results and additional benefits: Significant cost savings vs infusion pump Convenient sample and calibrant introduction by direct infusion Very low and controlled flow rate Syringe Pump and evol Flow Profiles µl Syringe 5 µl/min Portable does not require constant connection to a power source Program and save methods Compact Arbitrary Intensity Arbitrary Intensity Syringe Pump evol Conditions: m/z Na (NaCOOH) 3, n = 3 replicates of each run. Positive ion mode, Mass range m/z. End plate voltage -450 V, Capillary voltage V, Nebuliser 16 psi, Dry gas 5.0 ml/min, Dry temperature 180 C, External calibration sodium formate. SPE is well known as a preparative technique for sample analysis using GC-MS or LC-MS. Opiate detection in Urine evol MEPS provides fast, easy sample preparation and the digital syringe format allows convenient sample introduction by direct infusion into the ESI-MS. Below is the analysis of opiate metabolites extracted from Urine using reversed-phase MEPS and infused directly into the ESI-MS source. MS Conditions Positive ion mode Mass range m/z. End plate voltage -500 V Capillary voltage V Nebuliser 25 psi Dry gas 4.0 ml/min Dry temperature 180 C External calibration sodium formate ± ± ± ± ± Masses Codeine-6-Glucuronide m/z Morphine-6-Glucuronide m/z Morphine-3-Glucuronide m/z Codeine m/z Morphine m/z Norcodeine m/z Normorphine m/z Figure 2. Extracted Ion Chromatogram of Dilute Urine Processed Using MEPS and Infused Directly into the ESI Source.

6 SilTite FingerTite The Smart Alternative This next generation GC ferrule has been designed to be installed only with the force of your fingers (no tools required) delivering an easy, leak and maintenance free seal. Why is it a next generation connection? 0 % Graphite Graphite Vespel SilTite FingerTIte Mechanical Strength Soft Hard Hard Temperature Limit 450 C 350 C No practical limit Grip strength on column Soft Moderate Strong Doesn t need retightening after installation x Ideal for GC-MS applications (minimal porosity) x No tools required for installation and removal x x Permanent positioning of ferrule x x / No deterioration x x Cannot break the capillary column with over-tightening x x No column creep x x Chemically inert x x Who benefits from this product? GC-MS users SilTite FingerTite has been developed with the unique, leak and air free properties of SilTite ferrules, resulting in superior air tightness to reduce background noise in sensitive MS applications so you can use them with confidence. % Response of Base Fragment 69 m/z Graphite Vespel ferrule Relative Abundances: 28/69 = 9.08 Nitrogen % 32/69 = 2.56 Oxygen % Air m/z Figure 1. MS trace using a Graphite Vespel ferrule after 5 temperature cycles. SilTite FingertTite ferrule % Response of Base Fragment 69 m/z Relative Abundances: 28/69 = 0.97 Nitrogen % 32/69 = 0.39 Oxygen % No Air m/z Figure 2. MS trace using a SilTite FingertTite ferrule after 5 temperature cycles. (Using an MS, no leaks can be detected, even after 400 temperature cycles between 70 ºC and 400 ºC).

7 GC Capillary Column Range The High Five The complete polysilphenylene and polycarborane GC column range New BP5MS optimized silphenylene column 5 Selectivities to suit your analyses A Variety of Selectivities to Suit Your Analyses Introducing the new BP5MS GC column completing the SGE High Five range of capillary columns. BP5MS Optimized Silphenylene content for general purpose MS analyses BP5 For general purpose analyses BPX5 Extremely inert, suitable for general purpose analyses, ideal for trace analysis HT5 Unique phase for high temperature applications HT8 The preferred column for polychlorinated biphenyl (PCB) compounds Optimized Silphenylene Content for General Purpose MS Analyses Evaluating Organo Chlorine Pesticides (OCP) on BP5MS. Instrument: TRACE GC/POLARIS-Q Carrier gas: He (1.5 ml/min) Injector: Split/Splitless mode Injector Temp: 275 C Split Mode: Splitless (1 min split valve closed) Split Flow: 30 ml/min Column: 30 m x 0.25 mm x 0.25 µm BP5MS (P/N 0543) Oven Temperature: 60 C (5 min) 8 C/min 300 C ( min) MS Transfer Line Temperature: 300 C MS Type: ITD MS Source Temperature: 225 C MS Acquisition Mode: Segmented Scan amu

8 GC Column Comparison Table Overview Perfect for your 5% MS analysis. Non polar, 5% equivalence. Low bleed, great inertness Minimum Temperature ( C) Maximum Continuous Temperature ( C) Maximum Cycling Temperature ( C) Phase Structure BP5MS BP5 BPX5 HT5 HT8 A general purpose phase with excellent high temperature characteristics. Popular column range used for a wide variety of applications A highly inert phase, suitable for MS use. It has been designed for robustness and is suitable for over 80% of all routine analyses performed by chromatographers Unique high temperature phase suited for simulated distillation and other petroleum applications High temperature and low bleed column for polychlorinated biphenyl (PCB) compounds Separates PCB s on ortho-ring substitution as well as boiling point Industry Suited Trace Analysis General Purpose General Purpose General Purpose Fuels, Environment, Food Environment Optimized for MS analysis Yes - Yes - - Polarity Non-polar Non-polar Non-polar Low polarity Low polarity Solvent Rinsable Yes - Ordering Information For more information on SGE MS specialized products, visit contact your local SGE ofiice or your local distributor. BR-0000-H SGE Analytical Science Pty Ltd 05/2012 AUSTRALIA & PACIFIC REGION SGE Analytical Science Pty Ltd 7 Argent Place, Ringwood Victoria 3134 Australia Toll Free: Tel: +61 (0) Fax: +61 (0) support@sge.com JAPAN SGE Japan Inc RK CUBE 3F 6-85, Ohta-machi Naka-Ku, Yokohama-shi Kanagawa Japan Tel: Fax: japan@sge.com EUROPE SGE Europe Ltd European Head Office 1 Potters Lane Kiln Farm Milton Keynes MK11 3LA United Kingdom Toll Free: Toll Free Fax: Tel: Fax: Tel France: Fax France: Tel Germany: +49 (0) 6155 / Fax Germany: +49 (0) 6155 / europe@sge.com UNITED STATES OF AMERICA SGE Incorporated 2007 Kramer Lane Austin Texas USA Toll Free: (800) Tel: Fax: usa@sge.com

Choose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide

Choose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide Choose for Your Instrument GC Supplies - Shimadzu Instrument Quick Pick Guide Syringes Septa Inlet Liners O-rings and Sealing Rings SilTite FingerTite Ferrules Ferrules Replacement Parts Your chromatography

More information

HT5 - High Temperature Stationary Phase for Capillary Gas Chromatography

HT5 - High Temperature Stationary Phase for Capillary Gas Chromatography HT5 - High Temperature Stationary Phase for Capillary Gas Chromatography INTRODUCTION HT5 was the first carborane modified siloxane phase to be commercially available on fused silica capillary columns.

More information

Gas Chromatography Syringe Selection Guide

Gas Chromatography Syringe Selection Guide Gas Chromatography Syringe Selection Guide Peter Morgan, Fisher, Runcorn, Cheshire, UK Technical Note 20552 Key Words Syringe selection Abstract Choosing the correct syringe from the wide selection available

More information

Analyze Drugs of Abuse with Agilent J&W Ultimate Plus Tubing in an Inert Flow Path

Analyze Drugs of Abuse with Agilent J&W Ultimate Plus Tubing in an Inert Flow Path Analyze Drugs of Abuse with J&W Ultimate Plus Tubing in an Inert Flow Path Application Note Forensic Toxicology Author Ngoc A Dang Technologies, Inc. Abstract J&W Ultimate Plus deactivated fused silica

More information

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN784 Extraction of Multiple Mycotoxins from Nuts Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis This application note

More information

Needle Gauge. Needle OD (mm) Needle ID (mm)

Needle Gauge. Needle OD (mm) Needle ID (mm) s LC Manual s Beckman/Altex, Rheodyne, SSI Instruments and Valco Valves s and Borosilicate Glass Barrel Outer Diameter () Scale 5 µl and 10 µl = 6.5 mm, 25 µl to 500 µl = 8 mm, 1 ml = 8.8 mm, 2.5 ml =

More information

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN782 Extraction of Multiple Mycotoxins from Grain Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis This application

More information

A FORENSIC TOXICOLOGY METHOD FOR THE DETERMINATION OF DESOMORPHINE, HEROIN, METHADONE, BUPRENORPHINE AND METABOLITES IN URINE USING LC/MS QQQ

A FORENSIC TOXICOLOGY METHOD FOR THE DETERMINATION OF DESOMORPHINE, HEROIN, METHADONE, BUPRENORPHINE AND METABOLITES IN URINE USING LC/MS QQQ FORENSICS MARKET A FORENSIC TOXICOLOGY METHOD FOR THE DETERMINATION OF DESOMORPHINE, HEROIN, METHADONE, BUPRENORPHINE AND METABOLITES IN URINE USING LC/MS QQQ Desomorphine, also known by its street name

More information

autosamplers ASI-100 and ASI-100T Autosamplers

autosamplers ASI-100 and ASI-100T Autosamplers autosamplers ASI-100 and ASI-100T Autosamplers The ASI-100 and ASI-100T Automated Sample Injectors are highly flexible autosamplers for automating high performance liquid chromatography (HPLC) methods.

More information

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants Jeremy Matthews, 1 Alex Chen, 2 and Flavio Bedini 1 1 Thermo Fisher Scientific, Singapore; 2 Alpha Analytical Pte Ltd, Singapore Overview

More information

Simple Strategies for GC/MS Success. Rachael Simon Agilent Technologies Product Manager, Gas Chromatography Supplies

Simple Strategies for GC/MS Success. Rachael Simon Agilent Technologies Product Manager, Gas Chromatography Supplies Simple Strategies for GC/MS Success Rachael Simon Agilent Technologies Product Manager, Gas Chromatography Supplies 1 Time robbers in the GC/MS lab Looking for leaks Frequent leaks affect sensitivity,

More information

Rapid and Robust Detection of THC and Its Metabolites in Blood

Rapid and Robust Detection of THC and Its Metabolites in Blood Rapid and Robust Detection of THC and Its Metabolites in Blood Application Note Forensics/Doping Control Author Stephan Baumann Agilent Technologies, Inc. Santa Clara CA 95051 USA Abstract A robust method

More information

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Application Note: 346 MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Gargi Choudhary and Diane Cho, Thermo Fisher Scientific, San Jose, CA Wayne Skinner and

More information

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis Application Note AN807 Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco Page Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco SPE Columns prior to LC-MS/MS Analysis This application

More information

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA

More information

Results of Using Re-washed Vials and Closures

Results of Using Re-washed Vials and Closures Results of Using Re-washed Vials and Closures Loy Shick, Thermo Fisher Scientific, Rockwood, TN, USA Brian King, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20670 Key Words Autosampler,

More information

Analysis of Omega 3 and Omega 6 FAMEs in Fish Oil and Animal Fat Using an Agilent J&W DB-FATWAX Ultra Inert GC Column

Analysis of Omega 3 and Omega 6 FAMEs in Fish Oil and Animal Fat Using an Agilent J&W DB-FATWAX Ultra Inert GC Column Application Note Food Analysis of Omega 3 and Omega 6 FAMEs in Fish Oil and Animal Fat Using an Agilent J&W DB-FATWAX Ultra Inert GC Column Authors Ingrid Van Der Meer, Yun Zou, and Gustavo Serrano Agilent

More information

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Xiang He 1, Adrian Taylor 2 and Alexandre Wang 1 1 SCIEX, Redwood City, USA. 2 SCIEX, Concord,

More information

AS Application Note 1602

AS Application Note 1602 Determination of the fatty acid composition in refined oils and fats by alkaline transesterification by the ASAN 1602 Status: February 2018 Page 1 / 12 Introduction Animal and vegetable fats play a key

More information

Agilent 1220 Infinity LC System Performance Specifications

Agilent 1220 Infinity LC System Performance Specifications IET International Equipment Trading, Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 1220 Infinity LC System Performance

More information

Extraction of 11-nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE. SLE+ Prior to GC/MS Analysis

Extraction of 11-nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE. SLE+ Prior to GC/MS Analysis Application Note AN84 Extraction of -nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE SLE+ Page Extraction of -nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE SLE+

More information

Innovations in Large Volume Injection

Innovations in Large Volume Injection Innovations in Large Volume Injection Applications of a Chromatographic Zone as Inlet System for GC/MS Jeffery S. Hollis APEX Technologies Silicon Valley, Introduction In typical GC/MS analyses, only a

More information

Colonne Gascromatografiche

Colonne Gascromatografiche SGE dispone di un ampia gamma di colonne capillari per GC utilizzabili praticamente in qualunque applicazione cromatografica. Di seguito sono riportate in modo sintetico le principali caratteristiche dei

More information

injections. Needle Tip 1 µl Cone 1BR

injections. Needle Tip 1 µl Cone 1BR s General Purpose Manual s 0.5-5 µl Nano With the ability to inject down to 50 nl with high precision and accuracy, SGE Nano s are perfect for Nano capillary chromatography injection as well as making

More information

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System Application Note Food Testing and Agriculture Mass-Based Purification of Natural Product Impurities Using an Agilent 126 Infinity II Preparative LC/MSD System Authors Florian Rieck and Jörg Hippler Agilent

More information

Separation of 37 Fatty Acid Methyl Esters Utilizing a High-Efficiency 10 m Capillary GC Column with Optimization in Three Carrier Gases

Separation of 37 Fatty Acid Methyl Esters Utilizing a High-Efficiency 10 m Capillary GC Column with Optimization in Three Carrier Gases APPLICATION NOTE Separation of 37 Fatty Acid Methyl Esters Utilizing a High-Efficiency 10 m Capillary GC Column with Optimization in Three Carrier Gases No. 21557 Aaron L. Lamb Thermo Fisher Scientific,

More information

Forensic Analysis of Blood Alcohol Concentration

Forensic Analysis of Blood Alcohol Concentration Application Note Forensics Forensic Analysis of Blood Alcohol Concentration Using the Agilent 886 GC with Agilent J&W DB BAC1 UI and Agilent J&W DB-BAC2 UI columns and the Agilent 7697A headspace sampler

More information

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) Michael Rummel, Matthew Trass, Michael Campognone, and Sky Countryman Phenomenex, Inc., 411 Madrid Avenue, Torrance,

More information

Liquid Chromatography Syringes

Liquid Chromatography Syringes Liquid Chromatography Syringes Hamilton manufactures a complete range of high performance liquid chromatography (HPLC) syringes and thin layer chromatography (TLC) syringes. HPLC Syringes HPLC syringes

More information

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine High-Throughput Quantitative LC-MS/MS Analysis of and 14 Benzodiazepines in Urine Bill Yu, Kristine Van Natta, Marta Kozak, Thermo Fisher Scientific, San Jose, CA Application Note 588 Key Words Opiates,

More information

Analysis of several common. organic acids in tobacco leaf, snus, and moist snuff

Analysis of several common. organic acids in tobacco leaf, snus, and moist snuff Analysis of several common organic acids in tobacco leaf, snus, and moist snuff S. C. Moldoveanu, W. A. Scott R.J. Reynolds Tobacco Co. Background Among the organic acids commonly present in tobacco, are

More information

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography Application Note Metabolomics Author Yuqin Dai Agilent Technologies, Inc. 31 Stevens Creek Blvd,

More information

Agilent 1260 Infinity Analytical SFC System

Agilent 1260 Infinity Analytical SFC System Agilent 1260 Infinity Analytical SFC System Installation Instructions: Checkout Procedure This technical note describes the checkout procedures for the Agilent 1260 Infinity Analytical SFC System. Contents

More information

Chromatography Vacuum Ultraviolet Spectroscopy

Chromatography Vacuum Ultraviolet Spectroscopy Application Note Differentiation and Determination Differentiation and Determination of Fatty Acid Methyl of Fatty Esters Acid by Gas Methyl Chromatography Esters by Vacuum Gas Ultraviolet Spectroscopy

More information

using the Agilent 7696A Sample Prep

using the Agilent 7696A Sample Prep Automated Clean-up for Mineral Oil (Hydrocarbon Oil Index) Analysis using the Agilent 7696A Sample Prep WorkBench Application Note Automated Sample Preparation Authors Frank David, Karine Jacq, and Bart

More information

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research Dominic Foley, Michelle Wills, and Lisa Calton Waters Corporation, Wilmslow, UK APPLICATION

More information

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS TECHNICAL NOTE 21883 Fast and easy separation of 23 drugs of abuse including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS Authors Kean Woodmansey 1, Jon Bardsley 1 and Stacy

More information

Application. Detection of Cannabinoids in Oral Fluid Using Inert Source GC/MS. Introduction. Authors. Abstract. Forensic Toxicology

Application. Detection of Cannabinoids in Oral Fluid Using Inert Source GC/MS. Introduction. Authors. Abstract. Forensic Toxicology Detection of Cannabinoids in Oral Fluid Using Inert Source GC/MS Application Forensic Toxicology Authors Christine Moore, Sumandeep Rana, and Cynthia Coulter Immunalysis Corporation 829 Towne Center Drive

More information

Mass Directed Flash Chromatography by Biotage. Biotage Dalton Mass Detectors

Mass Directed Flash Chromatography by Biotage. Biotage Dalton Mass Detectors Mass Directed Flash Chromatography by Biotage Biotage Dalton Mass Detectors Why Do Companies Around the World Choose the Biotage Approach to Flash Purification? As a pioneer of automated Flash purification,

More information

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079 Ultra High Performance Liquid Chromatograph Nexera X2 C196-E79 Maximizing the Potential of UHPLC/HPLC Analyses Intelligence Intelligent data solutions, including a new i -PDeA peak calculation method for

More information

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa Application Note Small Molecule Pharmaceuticals & Generics Author Mike Chang Agilent Technologies, Inc. 5 Commercentre

More information

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these

More information

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices Application ote #LCMS-2 esquire series Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices Introduction The simple monitoring

More information

LC-MS/MS Method for the Determination of Tenofovir from Plasma

LC-MS/MS Method for the Determination of Tenofovir from Plasma LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract

More information

Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System

Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System Application Note Forensics, Workplace Drug Testing Detection of Cannabinoids in Oral Fluid with the Agilent 7010 GC-MS/MS System Authors Fred Feyerherm and Anthony Macherone Agilent Technologies, Inc.

More information

Single Quadrupole Compact Mass Spectrometer for Liquid Sample

Single Quadrupole Compact Mass Spectrometer for Liquid Sample Single Quadrupole Compact Mass Spectrometer for Liquid Sample YL INSTRUMENT CO., LTD. YL9900 MS quickly provides essential information and improves the chemist's workflow. Mordern organic labs have become

More information

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS Introduction Drug analysis from whole blood is gaining popularity due to a more complete measurement

More information

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager Quick Start Guide Step 1. Calibrate the Q-TOF LC/MS for low m/z ratios 2 Step 2. Set up a Flow Injection Analysis (FIA) method for

More information

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky

More information

Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS

Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS Application Note 269 Identification and Quantification at ppb Levels of Common Cations and Amines by IC-MS INTRODUCTION Ion chromatography (IC) has been extensively used as the preferred separation technique

More information

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research Stephen Balloch and Gareth Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS Analytical selectivity afforded by mass selective detection Wide linear measuring range Simple, inexpensive sample

More information

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS TECHNICAL NOTE 21882 Robust extraction, separation, and quantitation of structural isomer steroids human plasma by SPE-UHPLC-MS/MS Authors Jon Bardsley 1, Kean Woodmansey 1, and Stacy Tremintin 2 1 Thermo

More information

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS Application Note Clinical Research Authors Frank David and Bart Tienpont, Research Institute for Chromatography,

More information

Quantitative Analysis of -Hydroxybutyrate in Hair Using Target Analyte Finding Processing of Comprehensive GC-HRT Data

Quantitative Analysis of -Hydroxybutyrate in Hair Using Target Analyte Finding Processing of Comprehensive GC-HRT Data Quantitative Analysis of -Hydroxybutyrate in Hair Using Target Analyte Finding Processing of Comprehensive GC-HRT Data LECO Corporation; Saint Joseph, Michigan USA Key Words: Pegasus GC-HRT, GHB, Hair,

More information

4-Fluoroethamphetamine

4-Fluoroethamphetamine NMS Labs 2300 Stratford Ave Willow Grove, PA 19090 4-Fluoroethamphetamine Sample Type: Seized Material Latest Revision: January 3, 2019 Date Received: July 31, 2018 Date of Report: January 3, 2019 1. GENERAL

More information

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer A Robustness Study for the Agilent 7 LC-MS/MS Mass Spectrometer Application Note Clinical Research Authors Linda Côté, Siji Joseph, Sreelakshmy Menon, and Kevin McCann Agilent Technologies, Inc. Abstract

More information

Lipidomic Analysis by UPLC-QTOF MS

Lipidomic Analysis by UPLC-QTOF MS Lipidomic Analysis by UPLC-QTOF MS Version: 1 Edited by: Oliver Fiehn Summary Reagents and Materials Protocol Summary:Lipidomic analysis by UPLC-QTOF mass spectrometry Reagents and Materials: Reagent/Material

More information

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value Agilent 64 Triple Quadrupole LC/MS Sensitivity, Reliability, Value Sensitivity, Reliability, Value Whether you quantitate drug metabolites, measure herbicide levels in food, or determine contaminant levels

More information

Rapid Analysis of 37 FAMEs with the Agilent 8860 Gas Chromatograph

Rapid Analysis of 37 FAMEs with the Agilent 8860 Gas Chromatograph Application Note Food Rapid Analysis of 37 FAMEs with the Agilent 88 Gas Chromatograph Author Youjuan Zhang Agilent Technologies (Shanghai) Co. Ltd., Shanghai 131 P. R. China Abstract An Agilent 88 GC

More information

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS Jenny Chen, Hongxia Wang, Zhiqi Hao, Patrick Bennett, and Greg Kilby Thermo Fisher

More information

ANALYTICAL REPORT 5F-MDMB-PINACA (C20H28FN3O3) methyl 2-{[1-(5-fluoropentyl)-1H-indazol-3-yl]formamido}-3,3-dimethylbutanoate

ANALYTICAL REPORT 5F-MDMB-PINACA (C20H28FN3O3) methyl 2-{[1-(5-fluoropentyl)-1H-indazol-3-yl]formamido}-3,3-dimethylbutanoate Vodovodna 95 1000 Ljubljana SLOVENIJA ANALYTICAL REPORT 5F-MDMB-PINACA (C20H28FN3O3) methyl 2-{[1-(5-fluoropentyl)-1H-indazol-3-yl]formamido}-3,3-dimethylbutanoate Remark other NPS detected: none Sample

More information

Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer

Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer APPLICATION NOTE 72819 Detection of oxygenated polycyclic aromatic hydrocarbons (oxy-pahs) in APCI mode with a single quadrupole mass spectrometer Author Maria Grübner; Thermo Fisher Scientific, Germering,

More information

More accurate results.

More accurate results. More choices. More productivity. More accurate results. Agilent's Complete Line of Autosampler and Manual Syringes Specifications and Selection Guide Table of Contents Introduction to Agilent Syringes...2

More information

ANALYTICAL REPORT 1. bk-2c-b ( C10H12BrNO3) 2-amino-1-(4-bromo-2,5-dimethoxyphenyl)ethan-1-one

ANALYTICAL REPORT 1. bk-2c-b ( C10H12BrNO3) 2-amino-1-(4-bromo-2,5-dimethoxyphenyl)ethan-1-one Vodovodna 95 1000 Ljubljana SLOVENIJA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1 bk-2c-b ( C10H12BrNO3) 2-amino-1-(4-bromo-2,5-dimethoxyphenyl)ethan-1-one

More information

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS application LC/MS Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS Introduction Many kinds of natural colors are used in beverages,

More information

Automated Analysis and Quantitation of Fish Oil Supplements using the MIDI Sherlock Marine Oil Analysis Package

Automated Analysis and Quantitation of Fish Oil Supplements using the MIDI Sherlock Marine Oil Analysis Package 125 Sandy Drive, Newark, Delaware 19713 USA tel: 302-737-4297 fax: 302-737-7781 www.midi-inc.com Automated Analysis and Quantitation of Fish Oil Supplements using the MIDI Sherlock Marine Oil Analysis

More information

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer application Note Liquid Chromatography/ Mass Spectrometry Authors Sharanya Reddy Blas Cerda PerkinElmer, Inc. Shelton, CT USA Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate

More information

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine J. Jones, S. Westwood, T. Liddicoat, L. Pereira, T. Edge Thermo Fisher Scientific, Manor Park, Runcorn, UK Overview Purpose:

More information

Uptake and Metabolism of Phthalate Esters by Edible Plants

Uptake and Metabolism of Phthalate Esters by Edible Plants 1 Supporting Information for 2 3 Uptake and Metabolism of Phthalate Esters by Edible Plants 4 Jianqiang Sun, Xiaoqin Wu, Jay Gan * 5 6 7 Department of Environmental Sciences, University of California,

More information

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System Keywords Introduction Application Note PHA0413 High Pressure Liquid Chromatography

More information

PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES. DR. A. RAMESH, Ph.D, D.Sc.,

PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES. DR. A. RAMESH, Ph.D, D.Sc., PHOTOCATALYTIC DECONTAMINATION OF CHLORANTRANILIPROLE RESIDUES IN WATER USING ZnO NANOPARTICLES DR. A. RAMESH, Ph.D, D.Sc., raamesh_a@yahoo.co.in 1 OBJECTIVES Determination of persistence and photolysis

More information

Determination of Gamma-Hydroxy-Butyrate (GHB) in Biological Samples

Determination of Gamma-Hydroxy-Butyrate (GHB) in Biological Samples Determination of Gamma-Hydroxy-Butyrate (GHB) in Biological Samples Application Note Forensic Toxicology Authors Joe Crifasi Saint Louis University Forensic Toxicology Laboratory Saint Louis, MO, USA Ron

More information

Improved Characterization of Perfumes with GC GC-TOFMS

Improved Characterization of Perfumes with GC GC-TOFMS Improved Characterization of Perfumes with LECO Corporation; Saint Joseph, Michigan USA Key Words: Pegasus 4D, Peak Capacity, Thermal Focusing, Structured Chromatograms, Perfume Analysis 1. Introduction

More information

ANALYTICAL REPORT 1 DPT (C16H24N2) [2-(1H-indol-3-yl)ethyl]dipropylamine.

ANALYTICAL REPORT 1 DPT (C16H24N2) [2-(1H-indol-3-yl)ethyl]dipropylamine. Vodovodna 95 1000 Ljubljana SLOVENIJA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1 DPT (C16H24N2) [2-(1H-indol-3-yl)ethyl]dipropylamine

More information

Hamilton Syringes. LT N LTN RN TLL TLL with slots. Hamilton Syringe Types Microliter. Hamilton Point Styles

Hamilton Syringes. LT N LTN RN TLL TLL with slots. Hamilton Syringe Types Microliter. Hamilton Point Styles Hamilton LT N LTN RN TLL TLL with slots Hamilton Point Styles Pt. 2 Pt. 3 Pt. 5 Pt. HP Hamilton syringes are designed as precision measuring instruments, and find wide use for sample introduction into

More information

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ Application Note Clinical Research Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ Authors Jennifer Hitchcock 1, Lauren Frick 2, Peter Stone 1, and Vaughn Miller 2 1 Agilent

More information

Rapid Separation of Fatty Acid Methyl Esters

Rapid Separation of Fatty Acid Methyl Esters Application Note Food Testing & Agriculture Rapid Separation of Fatty Acid Methyl Esters Using DB-FastFAME Intuvo GC columns Author Yun Zou Agilent Technologies (Shanghai) Co. Ltd. Shanghai 200131 P. R.

More information

ANALYTICAL REPORT 1 3C-P (C14H23NO3) 1-(3,5-dimethoxy-4-propoxylphenyl)propan-2-amine.

ANALYTICAL REPORT 1 3C-P (C14H23NO3) 1-(3,5-dimethoxy-4-propoxylphenyl)propan-2-amine. Vodovodna 95, 1000 LJUBLJANA, SLOVENIA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1 3C-P (C14H23NO3) 1-(3,5-dimethoxy-4-propoxylphenyl)propan-2-amine

More information

ANALYTICAL REPORT 1. N-methyl-2AI ( C10H13N) Remark other NPS detected: none. N-methyl-2,3-dihydro-1H-inden-2-amine. Sample ID:

ANALYTICAL REPORT 1. N-methyl-2AI ( C10H13N) Remark other NPS detected: none. N-methyl-2,3-dihydro-1H-inden-2-amine. Sample ID: Vodovodna 95 1000 Ljubljana SLOVENIJA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1 N-methyl-2AI ( C10H13N) N-methyl-2,3-dihydro-1H-inden-2-amine

More information

Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection

Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection Application Note Cannabis Qualitative and quantitative determination of cannabinoid profiles and potency in CBD hemp oil using LC/UV and Mass Selective Detection Authors Mike Adams, Annette Roth, Sue D

More information

Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222

Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222 Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222 Joan Stevens, Ph.D.; Luke Roenneburg; Tim Hegeman; Kevin Fawcett

More information

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Application Note Clinical Research Authors Derick Lucas and Limian Zhao Agilent Technologies, Inc. Abstract Lipids from

More information

Toxicology Screening of Whole Blood Extracts Using GC/Triple Quadrupole/MS

Toxicology Screening of Whole Blood Extracts Using GC/Triple Quadrupole/MS Toxicology Screening of Whole Blood Extracts Using GC/Triple Quadrupole/MS Application Note Forensic Toxicology Authors Bruce Quimby and Mike Szelewski Agilent Technologies, Inc. 2850 Centerville Road

More information

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution Joanne Mather, Steve Cubbedge, Debadeep Bhattacharya, and Robert S. Plumb Waters Corporation, Milford, MA, U.S. A P P L

More information

ANALYTICAL REPORT 1, 2

ANALYTICAL REPORT 1, 2 Vodovodna 95 1000 Ljubljana SLOVENIJA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1, 2 Phenibut (C10H13NO2) 4-amino-3-phenylbutanoic acid

More information

Designer Cannabinoids

Designer Cannabinoids Liquid Chromatography Mass Spectrometry SSI-LCMS-010 Designer Cannabinoids LCMS-8030 Summary A rapid LC-MS-MS method for determination of designer cannabinoids in smokeable herbs was developed. Background

More information

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Application Note LCMS-109 A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Time of Flight (LC-TOF) Mass Spectrometry Introduction Many clinical

More information

The Measure of Excellence. GC Autosampler Syringes. CTC GC PAL Autosampler Syringes (PAL is a registed trademark of CTC Analytics AG, Switzerland)

The Measure of Excellence. GC Autosampler Syringes. CTC GC PAL Autosampler Syringes (PAL is a registed trademark of CTC Analytics AG, Switzerland) The Measure of Excellence GC Autosampler Syringes For manual injection and for automatic injectors (autosamplers) from leading manufacturers you can choose from a wide variety of HAMILTON syringes. CTC

More information

Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS. Peio RISS ICP-MS Application Specialist.

Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS. Peio RISS ICP-MS Application Specialist. Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS Peio RISS ICP-MS Application Specialist aurora Elite Bruker ICP-MS aurora series The aurora series design All-digital

More information

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS A RAPID AD SESITIVE AALYSIS METD OF SUDA RED I, II, III & IV I TOMATO SAUCE USIG ULTRA PERFORMACE LC MS/MS Choon Keow G, aomi TAAKA, Michelle KIM, Swee Lee YAP Waters Asia, Regional Technology Center,

More information

Analysis of short chain organic acids in tobacco and in some flavored e-liquids

Analysis of short chain organic acids in tobacco and in some flavored e-liquids Analysis of short chain organic acids in tobacco and in some flavored e-liquids S.C. Moldoveanu, Karen B. Kilby, Amanda G. Hudson 1 Background Short chain organic acids from acetic to caprylic play an

More information

Determination of Amantadine Residues in Chicken by LCMS-8040

Determination of Amantadine Residues in Chicken by LCMS-8040 Liquid Chromatography Mass Spectrometry Determination of Amantadine Residues in Chicken by LCMS-8040 A method for the determination of amantadine in chicken was established using Shimadzu Triple Quadrupole

More information

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates Application Note Clinical Research Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates Authors Limian Zhao and Megan Juck Agilent Technologies, Inc. Abstract

More information

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions Simplifying Qual/Quan Analysis in Discovery DMPK using UPLC and Xevo TQ MS Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION The determination of the drug metabolism

More information

Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2

Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2 Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2 Ordering Information You may contact us via phone, fax, e-mail, or through our website. EPOND S.A. CP 389 CH-1800 Vevey Switzerland Phone:

More information

LC-Based Lipidomics Analysis on QTRAP Instruments

LC-Based Lipidomics Analysis on QTRAP Instruments LC-Based Lipidomics Analysis on QTRAP Instruments Junhua Wang and Paul RS Baker SCIEX LC-Based Lipidomics Analysis Topics Covered Lipid extraction techniques Hydrophilic Interaction Chromatography (HILIC)

More information

Impact of Chromatography on Lipid Profiling of Liver Tissue Extracts

Impact of Chromatography on Lipid Profiling of Liver Tissue Extracts Impact of Chromatography on Lipid Profiling of Liver Tissue Extracts Application Note Clinical Research Authors Mark Sartain and Theodore Sana Agilent Technologies, Inc. Santa Clara, California, USA Introduction

More information

ANALYTICAL REPORT 1, 2

ANALYTICAL REPORT 1, 2 Vodovodna 95 1000 Ljubljana SLOVENIJA T: +386 (0)1 428 44 93 E: nfl@policija.si www.policija.si Remark other NPS detected: none ANALYTICAL REPORT 1, 2 4-MEAP (C14H21NO) 2-(ethylamino)-1-(4-methylphenyl)pentan-1-one

More information

SUPPLEMENTARY MATERIAL

SUPPLEMENTARY MATERIAL SUPPLEMENTARY MATERIAL Artepillin C, is it a good marker for quality control of Brazilian Green Propolis? Cui-ping Zhang 1, Xiao-ge Shen 1, Jia-wei Chen 1, Xia-sen Jiang 1, Kai Wang 2, Fu-liang Hu 1 *

More information