Choose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide
|
|
- Annis Shields
- 5 years ago
- Views:
Transcription
1 Choose for Your Instrument GC Supplies - Shimadzu Instrument Quick Pick Guide Syringes Septa Inlet Liners O-rings and Sealing Rings SilTite FingerTite Ferrules Ferrules Replacement Parts
2 Your chromatography analysis does not end with the selection of the GC column. The combination of components selected for your instrument also make an important contribution to successful separations. SGE brings technology and chromatography expertise to improve your chromatography. SGE Supplies for Sample Preparation, Sample Introduction, and Separation SAMPLE INTRODUCTION - Syringes Our involvement in all areas of chromatography provides us with a unique understanding of your requirements enabling us to optimize syringe design for sample introduction. All our syringes, both manual and autosampler, incorporate SGE s Diamond Syringe Technology offering significantly improved levels of durability, clarity and accuracy. SGE has a comprehensive range of syringe options including plunger protection, removable or fixed needles, a range of needle gauge and length options as well as needle-tip style alternatives. SAMPLE INTRODUCTION - Septa The role of septa for GC analysis is key as many chromatographic problems are caused as a result of inappropriate septa material or inappropriate handling of the septa. Desired septa attributes: Reliably seal against the carrier gas pressure in the inlet. Capable of being pierced and resealed time after time. Capable of being pierced by the syringe needle without pieces of the septa being deposited in the GC inlet system. Must not contaminate or bleed material into the chromatographic system. SAMPLE INTRODUCTION GC Inlet Liners The GC Inlet liner is where the sample is introduced and vaporized into the gaseous phase. The design of the liner is crucial, as is liner deactivation, to ensure reproducible and accurate chromatography. SEPARATION - GC Connections (ferrules and fittings) SGE manufactures an array of connection types for GC use. Poorly defined or selected connections can lead to an increase in dead volume, leaks from cycled temperatures and mismatched tubing sizes.
3 Instrument Quick Pick for Shimadzu Autosampler Syringes All needles are 42 mm long with a cone point style. Shimadzu AOC14, AOC17 and AOC20 Volume Needle Gauge (OD mm) Syringe Code Syringe Pack Size Spare Needle Pack Size Spare Plunger Fixed Needle 5 µl 26 (0.47) 5F-S-0.47C µl 23 (0.63) 5F-S-0.63C Removable Needle 0.5 µl 26 (0.47) 0.5BR-S-0.47C * 0.5 µl 23 (0.63) 0.5BR-S-0.63C * 10 µl 26 (0.47) 10R-S-0.47C µl 23 (0.63) 10R-S-0.63C µl Gas Tight 23 (0.63) 10R-S-GT-0.63C *Denotes spare Needle and Plunger kit. Pack Size Septa SGE has a number of different septa materials: Enduro Blue = For non-demanding routine applications. EC = Combines significantly longer injection life, low bleed and low injection port adhesion. HT = Bleed and temperature optimized, combined with outstanding mechanical properties. Type Material Durability Resealing Solvent Resistance Enduro Blue Tear Resistance Maximum Temperature High Temperature Silicone Excellent Excellent Excellent Excellent 350 C EC High Temperature Silicone Excellent Excellent Excellent Excellent 400 C HT BTO Silicone Excellent Excellent Excellent Excellent 400 C Septum Type Pack Size For Shimadzu 9A, 14, 15A, 16, 17A, 2010 & 2014 Enduro Blue EC HT Inlet Liners Length Description and Geometry Sketch OD (mm) ID (mm) Pack Size (mm) For GC-2010 (SPL-2010 Injector), GC-2014 (SPL-2014 Injector) and GC-17A (SPL-17 Injector) Split / Splitless FocusLiner * Split / Splitless Tapered FocusLiner * Split / Splitless FocusLiner Split / Splitless Tapered FocusLiner
4 Inlet Liners Continued Description and Geometry Sketch OD (mm) ID (mm) Length (mm) Pack Size ConnecTite Liner Standard ConnecTite Liner Top Hole ConnecTite Liner Bottom Hole Split, straight-through liner Splitless straight-through liner Split / Splitless with Single Taper Split / Splitless with middle gooseneck Split / Splitless with recessed gooseneck and quartz wool Split / Splitless with middle gooseneck ConnecTite (0.53 mm ID columns) SPME Liner For GC-14(SPL-14 Injector) Split / Splitless FocusLiner Split / Splitless Tapered FocusLiner Split / Splitless with 2.0 mm middle gooseneck Split / Splitless with single taper Splitless, Direct, wide bore liner for Shimadzu 9A/16A GC * When using a standard 42 mm needle for autosamplers, the sample will be injected on top of the wool for this liner. O-rings and Sealing Rings Description Usage Pack Size Viton O-ring Can be used at temperatures up to 300 C. For 2010 & 2014 (SPL-2010 Injector & SPL Injector). Graphite Sealing Ring Can be used at temperatures up to 450 C. For 14, 15A & 16 (SPL-14 injector) Graphite Sealing Ring Can be used at temperatures up to 450 C. For 17A (SPL-17 injector)
5 SilTite FingerTite Ferrules Description Pack Size SilTite Fingertite Shimadzu 2010 INJ / FID Starter Kit * SilTite Fingertite Shimadzu 2010 INJ / MS Starter Kit * SilTite Fingertite Ferrule 0.4 mm Replacement Items SilTite Fingertite Ferrule 0.5 mm Replacement Items SilTite Fingertite Blanking Ferrule Replacement Items SilTite Fingertite Female Nut Replacement Items * Each starter kit includes all the parts necessary to convert one GC system (one injector and one detector) to the SilTite FingerTite system suitable for installing mm ID capillary columns. In addition there are five SilTite FingerTite nuts, one packet (ten ferrules) of 0.4 mm ID SilTite FingerTite ferrules and a ferrule install tool which allows you to seat the ferrule in the correct position on the capillary column. Ferrules Column ID Description Pack Size GC14A, GC17A, GC2010 and GC2014 Detector / Injectors (Not for MS interfaces or QP2010 Injector) mm ID columns 100% Graphite mm ID columns 100% Graphite mm OD packed columns 100% Graphite mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules n/a SilTite Metal Nuts - Slotted QP5000/5050 Standard MS Interface QP5000-I mm ID columns 15% Graphite/ 85% Vespel Ferrules QP5000-I 0.32 mm ID columns 15% Graphite/ 85% Vespel Ferrules QP5000-II & QP mm ID columns 15% Graphite/ 85% Vespel Ferrules QP5000-II & QP mm ID columns 15% Graphite/ 85% Vespel Ferrules mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules n/a SilTite Metal Nuts-QP5000/5050 Standard MS interface QP5000/5050 Wide Bore MS Interface, QP2010 Injector and QP2010 Standard MS Interface mm ID columns 15% Graphite/ 85% Vespel Ferrules mm ID columns 15% Graphite/ 85% Vespel Ferrules mm ID columns 15% Graphite/ 85% Vespel Ferrules mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules mm ID columns SilTite Metal - Initial Installation 10* mm ID columns SilTite Ferrules n/a SilTite Metal Nuts * Includes ten ferrules, two SilTite nuts. Replacement Parts Material Pack Size Replacement SilTite Nuts For 2010 GC-MS System For 2010 GC-MS System with QP5000 series MS For 2010/2014 GC Injectors and atmospheric detectors QP5000 Jet Separator MS Interface QP5000 Direct MS Interface For All Injectors Jet Separator (Starter Kit), except 2010/
6 SGE's involvement in gas chromatography includes the support we give to our customers. Technical Support Contact us at for technical support information. Our Website is a detailed source for information on chromatography, applications and SGE products. It also profiles the latest posters and materials developed by our technical experts based around the world. SGE Product Selection Guide Our product selection guide can be accessed at BR-0373-C_RevE SGE Analytical Science Pty Ltd 07/2013 AUSTRALIA AND PACIFIC REGION SGE Analytical Science Pty Ltd Toll Free: Tel: +61 (0) Fax: +61 (0) support@sge.com JAPAN SGE Japan Inc Tel: +81 (0) Fax: +81 (0) japan@sge.com EUROPE SGE Europe Ltd Tel: +44 (0) Fax: +44 (0) Tel France: +33 (0) Tel Germany: +49 (0) 6155 / europe@sge.com UNITED STATES OF AMERICA SGE Inc Toll Free: Tel: Fax: usa@sge.com
Sensitive, Accurate and Precise. MS Solutions Through SGE Products. Diamond MS Syringes evol XR MEPS SilTite FingerTite GC Capillary Columns
Sensitive, Accurate and Precise MS Solutions Through SGE Products Diamond MS Syringes evol XR MEPS SilTite FingerTite GC Capillary Columns AUSTRALIA & PACIFIC REGION EUROPE JAPAN USA Introduction Bringing
More informationGas Chromatography Syringe Selection Guide
Gas Chromatography Syringe Selection Guide Peter Morgan, Fisher, Runcorn, Cheshire, UK Technical Note 20552 Key Words Syringe selection Abstract Choosing the correct syringe from the wide selection available
More informationHT5 - High Temperature Stationary Phase for Capillary Gas Chromatography
HT5 - High Temperature Stationary Phase for Capillary Gas Chromatography INTRODUCTION HT5 was the first carborane modified siloxane phase to be commercially available on fused silica capillary columns.
More informationHamilton Syringes. LT N LTN RN TLL TLL with slots. Hamilton Syringe Types Microliter. Hamilton Point Styles
Hamilton LT N LTN RN TLL TLL with slots Hamilton Point Styles Pt. 2 Pt. 3 Pt. 5 Pt. HP Hamilton syringes are designed as precision measuring instruments, and find wide use for sample introduction into
More informationMore accurate results.
More choices. More productivity. More accurate results. Agilent's Complete Line of Autosampler and Manual Syringes Specifications and Selection Guide Table of Contents Introduction to Agilent Syringes...2
More informationNeedle Gauge. Needle OD (mm) Needle ID (mm)
s LC Manual s Beckman/Altex, Rheodyne, SSI Instruments and Valco Valves s and Borosilicate Glass Barrel Outer Diameter () Scale 5 µl and 10 µl = 6.5 mm, 25 µl to 500 µl = 8 mm, 1 ml = 8.8 mm, 2.5 ml =
More informationAnalysis of Omega 3 and Omega 6 FAMEs in Fish Oil and Animal Fat Using an Agilent J&W DB-FATWAX Ultra Inert GC Column
Application Note Food Analysis of Omega 3 and Omega 6 FAMEs in Fish Oil and Animal Fat Using an Agilent J&W DB-FATWAX Ultra Inert GC Column Authors Ingrid Van Der Meer, Yun Zou, and Gustavo Serrano Agilent
More informationinjections. Needle Tip 1 µl Cone 1BR
s General Purpose Manual s 0.5-5 µl Nano With the ability to inject down to 50 nl with high precision and accuracy, SGE Nano s are perfect for Nano capillary chromatography injection as well as making
More informationThe next level of True Blue Performance
In Stock Now! The next level of True Blue Performance Topaz GC inlet liners feature revolutionary technology and inertness to deliver the next level of: Deactivation Reproducibility Productivity www.restek.com/topaz
More informationThe Measure of Excellence. GC Autosampler Syringes. CTC GC PAL Autosampler Syringes (PAL is a registed trademark of CTC Analytics AG, Switzerland)
The Measure of Excellence GC Autosampler Syringes For manual injection and for automatic injectors (autosamplers) from leading manufacturers you can choose from a wide variety of HAMILTON syringes. CTC
More informationcataleg-inl-2007-def6.indd /01/ :27:30
140 cataleg-inl-2007-def6.indd 140 30/01/2009 17:27:30 Index Syringes Hamilton Syringes Content Page Content Page Hamilton General Information 142 Hamilton Syringes 143-146 700 Series MICROLITER Syringes
More informationICP-OES Organics Kit Installation Instructions
The ICP Organics Kit is an accessory for use with the Agilent ICP-OES instruments. It is available in two versions one for axial ICP-OES and the other for radial ICP-OES. It is used to analyze directly
More informationA comparison study of the analysis of volatile organic acids and fatty acids
Application Note Food Testing A comparison study of the analysis of volatile organic acids and fatty acids Using DB-FATWAX Ultra Inert and other WAX GC columns Author Yun Zou Agilent Technologies (Shanghai)
More informationAnalyze Drugs of Abuse with Agilent J&W Ultimate Plus Tubing in an Inert Flow Path
Analyze Drugs of Abuse with J&W Ultimate Plus Tubing in an Inert Flow Path Application Note Forensic Toxicology Author Ngoc A Dang Technologies, Inc. Abstract J&W Ultimate Plus deactivated fused silica
More informationForensic Analysis of Blood Alcohol Concentration
Application Note Forensics Forensic Analysis of Blood Alcohol Concentration Using the Agilent 886 GC with Agilent J&W DB BAC1 UI and Agilent J&W DB-BAC2 UI columns and the Agilent 7697A headspace sampler
More informationRestek PAL SPME Fibers cat.#
1 Restek PAL SPME Fibers cat.# 27478 27483 Solid phase microextraction (SPME) fibers are used to extract organic compounds from solid, liquid, and vapor matrices onto a stationary phase that is bonded
More informationPEEK SS Columns & Guard Columns
PEEK SS Columns & Guard Columns ~ Stainless Steel Analytical Columns ~ PEEK Columns ID 2.1, 4.0, 4.6 & 7.5 mm ~ Jour-Guard Cartridges Stainless Steel or PEEK ~ Stainless Steel End Fittings 1/4 OD Columns
More informationSyringe Guide. The Measure of Excellence for your application
Syringe Guide The Measure of Excellence for your application Unsurpassed Accuracy and Precision Hamilton syringes are the finest quality precision fluid measuring devices available. Top quality materials
More informationHPLC. Varian Dynamax Preparative HPLC Columns
HPLC Varian Dynamax Preparative HPLC Columns Preparative HPLC Simple, successful and economical Linear scale-up move from analytical separation to preparative purification quickly and simply. Dynamic Axial
More informationSeparation of 37 Fatty Acid Methyl Esters Utilizing a High-Efficiency 10 m Capillary GC Column with Optimization in Three Carrier Gases
APPLICATION NOTE Separation of 37 Fatty Acid Methyl Esters Utilizing a High-Efficiency 10 m Capillary GC Column with Optimization in Three Carrier Gases No. 21557 Aaron L. Lamb Thermo Fisher Scientific,
More informationCORESTA RECOMMENDED METHOD N 8
CORESTA RECOMMENDED METHOD N 8 DETERMINATION OF WATER IN THE MAINSTREAM SMOKE OF CIGARETTES BY GAS CHROMATOGRAPHIC ANALYSIS (August 1991) 1. FIELD OF APPLICATION The method is applicable to the particulate
More informationElemental Scientific Semiconductor Catalog for Thermo ELEMENT2
Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2 Ordering Information You may contact us via phone, fax, e-mail, or through our website. EPOND S.A. CP 389 CH-1800 Vevey Switzerland Phone:
More informationAutomated Analysis and Quantitation of Fish Oil Supplements using the MIDI Sherlock Marine Oil Analysis Package
125 Sandy Drive, Newark, Delaware 19713 USA tel: 302-737-4297 fax: 302-737-7781 www.midi-inc.com Automated Analysis and Quantitation of Fish Oil Supplements using the MIDI Sherlock Marine Oil Analysis
More informationCORESTA Recommended Method No. 84
Cooperation Centre for Scientific Research Relative to Tobacco E-Vapour Sub-Group CORESTA Recommended Method No. 84 DETERMINATION OF GLYCERIN, PROPYLENE GLYCOL, WATER, AND NICOTINE IN THE AEROSOL OF E-CIGARETTES
More informationInfinityLab Purification Capillary Kits
InfinityLab Purification Capillary Kits Technical Note This note describes the capillary connections for Agilent preparative systems. Agilent Technologies Contents Abbreviations 3 List of Modules 4 Overview
More informationResults of Using Re-washed Vials and Closures
Results of Using Re-washed Vials and Closures Loy Shick, Thermo Fisher Scientific, Rockwood, TN, USA Brian King, Thermo Fisher Scientific, Runcorn, Cheshire, UK Technical Note 20670 Key Words Autosampler,
More informationLiquid Chromatography Syringes
Liquid Chromatography Syringes Hamilton manufactures a complete range of high performance liquid chromatography (HPLC) syringes and thin layer chromatography (TLC) syringes. HPLC Syringes HPLC syringes
More informationSimple Strategies for GC/MS Success. Rachael Simon Agilent Technologies Product Manager, Gas Chromatography Supplies
Simple Strategies for GC/MS Success Rachael Simon Agilent Technologies Product Manager, Gas Chromatography Supplies 1 Time robbers in the GC/MS lab Looking for leaks Frequent leaks affect sensitivity,
More informationPEEK Columns & Guard Columns
INDEX PEEK Columns 103 Packing Devices 104 Column Coupler One-Piece Fingertight 105 In-Line Biocompatible Guard Column 106 Column End Plugs 107 Column End Plugs, Logotype 107 Disclaimer The maximum holding
More informationDISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management
DISCOVER NEW HORIZONS IN FLUID DRAINAGE Bringing Safety and Convenience to Fluid Drainage Management DRAIN ASEPT Pleural and Peritoneal Drainage Catheter System 600mL or 1,000mL Evacuated Drainage Bottle
More informationHTEC-500 and 700 Series Related
HTEC-500 and 700 Series Related Columns and Reagents 681.407.00 P3-AC -PC Prepacked AC Precolumn (3pcs/pkg) 450.00 3mm 681.406.00 P3-CH-PC Prepacked CH Precolumn (3 pcs/pkg) 450.00 3mm 681.405.00 P3-CA-PC
More information#20 Separation of Alcohols Using Gas Chromatography
#20 Separation of Alcohols Using Gas Chromatography Purpose: The purpose of this experiment is to determine the composition of an unknown alcohol mixture by using gas chromatography. Introduction: A gas
More informationAS Application Note 1602
Determination of the fatty acid composition in refined oils and fats by alkaline transesterification by the ASAN 1602 Status: February 2018 Page 1 / 12 Introduction Animal and vegetable fats play a key
More informationRapid Analysis of 37 FAMEs with the Agilent 8860 Gas Chromatograph
Application Note Food Rapid Analysis of 37 FAMEs with the Agilent 88 Gas Chromatograph Author Youjuan Zhang Agilent Technologies (Shanghai) Co. Ltd., Shanghai 131 P. R. China Abstract An Agilent 88 GC
More informationSTANDARD SAMPLE INTRODUCTION
STANDARD SAMPLE INTRODUCTION PFA and Polypropylene High-Efficiency MicroFlow Nebulizers MicroFlow nebulizers are resistant to clogging, are reliably self-aspirated or pumped and produce a fi ne aerosol
More informationOrdering Information You may contact us via phone, fax, , or through our website.
Elemental Scientific (ESI) designs and produces a range of sample introduction systems for the determination of trace element concentrations and isotope ratios in liquid samples when using inductively
More informationSavillex Technical Note
Savillex Technical Note C400d PFA Concentric Nebulizer for ICP-MS Summary The Savillex C-Flow 400d (C400d) PFA concentric nebulizer combines the reliability of a low flow glass concentric nebulizer with
More informationSelecting The Right Syringe
Selecting The Right Syringe Choosing the Right Hamilton Syringe for Your Application 1. Is your sample a gas or a liquid? For a gas sample, use a GASTIGHT syringe. GASTIGHT 1000, 1700 and 1800 Series 1000/1700
More informationImproving the Analysis of 37 Fatty Acid Methyl Esters
Application Note Food Testing Improving the Analysis of 37 Fatty Acid Methyl Esters Using Three Types of Capillary GC columns Authors Yun Zou Agilent Technologies (Shanghai) Co.Ltd, Shanghai 200131 P.R.China
More informationOrdering Information You may contact us via phone, fax, , or through our website.
(ESI) designs and produces a range of sample introduction systems for the determination of trace element concentrations and isotope ratios in liquid samples when using inductively coupled plasma instrumentation
More informationInterested in conducting your own webinar?
Interested in conducting your own webinar? Email webinars@bnpmedia.com An Automated System for the analysis of fatty acid methyl esters (FAME) in edible oils Institute for Food Safety and Health Illinois
More informationBlood Alcohol Determination with Teledyne Tekmar HT3 Automated Static/Dynamic Headspace Analyzer Application Note Introduction
Blood Alcohol Determination with Teledyne Tekmar HT3 Automated Static/Dynamic Headspace Analyzer Application Note By: Roger Bardsley Introduction Analysis of biological fluids for volatile components by
More informationType Analysis of Citrus Essential Oils by Multidimensional Supercritical Fluid Chromatography/ Gas Chromatography
25 Type Analysis of Citrus Essential Oils by Multidimensional Supercritical Fluid Chromatography/ Gas Chromatography Takashi YARITA, Akira NoMURA and Yoshiyuki HoRIMOTo Department of Analytical Chemistry,
More informationSavillex Technical Note
Savillex Technical Note C700d PFA Concentric Nebulizer for ICP-OES Summary The Savillex C-Flow 700d (C700d) is a concentric PFA nebulizer designed specifically for ICP-OES, combining extreme matrix tolerance
More informationINTEGRAL-BONNET NEEDLE VALVES H-300 SERIES
INTEGRAL-BONNET NEEDLE VALVES SERIES INTEGRAL-BONNET NEEDLE VALVES SERIES FEATURES n Straight and angle pattern n Stainless Steel and Brass construction n MAWP 5000 psi (345 bar) n MAWT 446 F (230 C) n
More informationGC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants
GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants Jeremy Matthews, 1 Alex Chen, 2 and Flavio Bedini 1 1 Thermo Fisher Scientific, Singapore; 2 Alpha Analytical Pte Ltd, Singapore Overview
More informationCalibration Standards
Calibration Standards/ Calibration Standards TSKgel standards polystyrene TSKgel standards poly(ethylene oxide) PStQuick polystyrene calibration standards TSKgel guard column products Fittings Pre-injector
More informationShimadzu s Guide to Vial Selection. Not all vials are the same
Shimadzu s Guide to Vial Selection Not all vials are the same The perfect vial? Struggling to find the right vial or microtiter plate? You are not alone! What material? Are all vials the same? The Perfect
More informationQuickSplitTM Flow Splitters
QuickTM Flow ters between 2 or more detectors such as Mass Spectroscopy and evaporative light scattering, UV, or IR. This is especially important when one of the detectors is destructive, such as Mass
More informationThermo Scientific Finntip Pipette Tips. HANDHELD PIPETTING Finntip Pipette Tips. Details
Thermo Scientific Finntip Pipette Tips Finntip* pipette tips are manufactured using high quality materials and the latest molding techniques for proven reliability. Thermo Scientific Finntip pipette tips
More informationEppendorf Research plus. Raise the limits NEW! Order no. A /GB4/10T/1109/FEEL/PRINT64 Printed in Germany
www.eppendorf.com/research-plus Your local distributor: www.eppendorf.com/worldwide Eppendorf AG 22331 Hamburg Germany Tel: +49 40 538 01-0 Fax: +49 40 538 01-556 E-mail: eppendorf@eppendorf.com Eppendorf
More informationRaise the limits. Eppendorf Research plus
NEW! NEW! Raise the limits Eppendorf Research plus A completely new experience Eppendorf Research plus Eppendorf sets a new standard in pipetting. The ultra light Eppendorf Research plus pipette meets
More informationDETERMINATION OF COMPOSITION OF TRIACYLGLYCEROLS AND COMPOSITION AND CONTENT OF DI-ACYLGLYCEROLS BY CAPILLARY GAS CHROMATOGRAPHY, IN VEGETABLE OILS
INTERNATIONAL OLIVE COUNCIL COI/T.20/Doc. No 32 November 2013 ENGLISH Original: ENGLISH Príncipe de Vergara, 154 28002 Madrid España Telef.: +34 915 903 638 Fax: +34 915 631 263 - e-mail: iooc@internationaloliveoil.org
More informationGC-µECD Analysis and Confirmation of Contract Laboratory Protocol Pesticides in Olive Oil
GC-µECD Analysis and Confirmation of Contract Laboratory Protocol Pesticides in Olive Oil Application Note Food Safety and Environmental Markets Authors Jennifer McCulley and Ken Lynam Agilent Technologies,
More informationYMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability
YMC-Actus Columns for Semi-preparative HPLC Selectivity Durability Loadability Fast semi-preparative chromatography Semi-preparative chromatography is the link between analytical HPLC and preparative LC.
More informationAutomated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS
Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS Application Note Clinical Research Authors Frank David and Bart Tienpont, Research Institute for Chromatography,
More informationSavillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES
Savillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES Summary The Savillex C-Flow 700d (C700d) is a concentric PFA nebulizer designed specifically for ICP-OES, combining extreme matrix
More informationCANNABIS TESTING ACCESSORIES
CANNABIS TESTING ACCESSORIES HPLC/GC/Sample Prep www.phenomenex.com/cannabis Popular Accessories for Cannabis Testing Cannabis Testing Accessories Sample Preparation Vials Sample Preparation Phenex Syringe
More informationMass Directed Flash Chromatography by Biotage. Biotage Dalton Mass Detectors
Mass Directed Flash Chromatography by Biotage Biotage Dalton Mass Detectors Why Do Companies Around the World Choose the Biotage Approach to Flash Purification? As a pioneer of automated Flash purification,
More informationBROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / VACUUM
BROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / ACUUM LAB TABLE OF CONTENTS Content Page Table of Content 2 Product Overview 3 BROEN UniFlex TM BASIC 4-5 Fittings for Non-burnig 2.0 Gases/acuum Turret
More informationInnovations in Large Volume Injection
Innovations in Large Volume Injection Applications of a Chromatographic Zone as Inlet System for GC/MS Jeffery S. Hollis APEX Technologies Silicon Valley, Introduction In typical GC/MS analyses, only a
More informationInline Filters (F Series) Catalog 4130-F July 2005
Inline Filters (F Series) Catalog 4130-F July 2005 Catalog 4130-F Introduction Parker are designed for protection of instrumentation systems from undesirable materials. Component changes or repair and
More informationOrdering Information You may contact us via phone, fax, , or through our website.
Elemental Scientific (ESI) designs and produces a range of sample introduction systems for the determination of trace element concentrations and isotope ratios in liquid samples when using inductively
More informationAnalytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP
Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 1 PFP Application Note Clinical Research Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd Abstract
More informationY s A P. n n. C o. e c. t o r s E R. e s. e l. e e d l I V. e d o s C l. vadsite The Transparent, Split Septum, Needleless Connector
I V T H N E R e e d l A P e l e s Y s C o n n e c t o r s e d o s C l vadsite The Transparent, Split Septum, Needleless Connector What is vadsite? vadsite is a Neutral Displacement Needleless Connector
More informationautosamplers ASI-100 and ASI-100T Autosamplers
autosamplers ASI-100 and ASI-100T Autosamplers The ASI-100 and ASI-100T Automated Sample Injectors are highly flexible autosamplers for automating high performance liquid chromatography (HPLC) methods.
More informationAm I getting the very best value from my UHPLC analyses?
Am I getting the very best value from my UHPLC analyses? Stephen Luke LC Columns Product Manager 1 Primary reasons for UHPLC use Very fast Very high resolution Column 2.1 x 50 mm Column 2.1 x 150 mm Run
More informationLipidomic Analysis by UPLC-QTOF MS
Lipidomic Analysis by UPLC-QTOF MS Version: 1 Edited by: Oliver Fiehn Summary Reagents and Materials Protocol Summary:Lipidomic analysis by UPLC-QTOF mass spectrometry Reagents and Materials: Reagent/Material
More informationDEVELOPMENT AND VALIDATION OF THE GC METHOD FOR THE QUANTITATIVE DETERMINATION OF SEMI-VOLATILE SOLVENTS IN THE PHARMACEUTICAL SUBSTANCE BOSENTAN
Acta Poloniae Pharmaceutica ñ Drug Research, Vol. 71 No. 6 pp. 1107ñ1113, 2014 ISSN 0001-6837 Polish Pharmaceutical Society DEVELOPMENT AND VALIDATION OF THE GC METHOD FOR THE QUANTITATIVE DETERMINATION
More informationUnion Bonnet Valves - VU6 Series
BlowOur Proof Back Seating Hardened Stem Thread Mountable Panel nut Metal Seal Bonnet Union Bonnet Valves VU6 Series Features Pressure rating up to 6000psig (13bar) @38 C (100 F) Temperature rating from
More informationThe challenging extraction of non-polar contaminants out of a non-polar vegetable oil sample
The challenging extraction of non-polar contaminants out of a non-polar vegetable oil sample Presented by Michael Ye ExTech, 2014 sigma-aldrich.com/analytical 1 Agenda 1. Background; why and how analyze
More informationDIAGMED HEALTHCARE. Disposable Injection Needles
DIAGMED HEALTHCARE Disposable Injection Needles The widest choice of both U.G.I and L.G.I needles available in the UK, designed to ensure safe, effective injection with the greatest ease of operation.
More informationSavillex Technical Note
Savillex Technical Note C-Flow PFA Microconcentric Nebulizer Range Summary The Savillex C-Flow PFA concentric nebulizer range comprises of the general purpose C700d (nominal uptake 700 ul/min), suitable
More informationExactly what you re looking for. High Quality Instruments for Vitreoretinal Surgery
Exactly what you re looking for High Quality Instruments for Vitreoretinal Surgery Exactly what you re For over a decade, MedOne has been helping retina surgeons around the world conquer complex surgical
More informationExtraction of 11-nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE. SLE+ Prior to GC/MS Analysis
Application Note AN84 Extraction of -nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE SLE+ Page Extraction of -nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE SLE+
More informationBall Valves. BV & BT Series. Features. Pressure vs. Temperature. Technical Data. Pressure Ratings
Ball Valves & Series Features Any end type and size combination available upon request Adjustable stem seal can be maintained in-line Panel mountable Bi-directional flow All valves are 00% factory tested
More informationLC-MS/MS Method for the Determination of Tenofovir from Plasma
LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract
More informationELEMENT 2/ ELEMENT XR Consumables and Parts Catalog
ELEMENT 2/ ELEMENT XR Consumables and Parts Catalog Revision B - 2 470 Analyze Detect Measure Control 2007 Thermo Fisher Scientific. All rights reserved. Viton is a registered trademark of DuPont Dow Elastomers.
More informationAgilent 1260 Infinity Analytical SFC System
Agilent 1260 Infinity Analytical SFC System Installation Instructions: Checkout Procedure This technical note describes the checkout procedures for the Agilent 1260 Infinity Analytical SFC System. Contents
More informationTHE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT
USER MANUAL THE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT 3 QUICK START GUIDE For those familiar with e-cigarettes, the steps below
More informationAutomated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222
Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222 Joan Stevens, Ph.D.; Luke Roenneburg; Tim Hegeman; Kevin Fawcett
More informationFujiCEM 2. Superior resin-modified glass. Force and Fusion technology. from GC. NEW SLIDE & LOCK system. ionomer luting cement with our innovative
NEW SLIDE & LOCK system FujiCEM 2 from GC Superior resin-modified glass ionomer luting cement with our innovative Force and Fusion technology for your total peace of mind. Take the next step in the dental
More informationAUTOMATED LIQUID HANDLING
AUTOMATED LIQUID HANDLING Instrument Syringes R THE MEASURE OF EXCELLENCE TM The Measure of Excellence Automated Instrument Syringes When it comes to precision fluid handling, rely on the leader. We ve
More informationMeasurement, Separations, and More. More than 2,000 Syringes and Accessories
Measurement, Separations, and More More than 2,000 and Accessories TABLE OF CONTENTS Table of Contents... 3 Manual Sample Transfer and Manual HPLC...3-4 Manual GC... 5 HPLC Autosampler... 6 Featured Product:
More informationAnalysis of Organic Acids and Alcohols Using the Agilent J&W DB-624UI Ultra Inert GC Column
Analysis of Organic Acids and Alcohols Using the Agilent J&W DB-624UI Ultra Inert GC Column Application Note Food Testing & Agriculture Authors Pat Sasso and Ken Lynam Agilent Technologies, Inc. Abstract
More informationProduct Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis
Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis Product # LS-UR2-2.1x100 Ludger Document # LS-uR2-DMB-Guide-v2.1 Ludger Ltd Culham Science Centre Oxford OX14 3EB United Kingdom
More informationThermo Scientific Finnpipette Manual Pipetting Systems. you can handle. anything
Thermo Scientific Manual Pipetting Systems you can handle anything Leader in Pipetting Technology Since the introduction of the first variable volume micropipette in 1971, more than four million Thermo
More informationAchieving Secure Sealing and Instrument Handling in 9 mm Screw Thread Chromatography Vials
Achieving Secure Sealing and Instrument Handling in 9 mm Screw Thread Chromatography Vials Dave Edwards, Thermo Fisher Scientific, Madison, WI, USA Loy Shick, Thermo Fisher Scientific, Suwanee, GA, USA
More informationBeaver-Visitec International. Ophthalmic and Microsurgical Product Catalog
Beaver-Visitec International Ophthalmic and Microsurgical Product Catalog Wet-Field Bipolar Instruments Wet-Field Eraser Straight Eraser styles are available in 18G, 20G, 20-23G tapered and 25G designs.
More informationINSTRUCTIONS FOR USE
Comfort Injects 50 Comfort-in INSTRUCTIONS FOR USE English user manual 1 Introduction Thank you for choosing the Comfort in Needle free Injection system, developed with your comfort and convenience in
More informationANALYSIS OF -HYDROXYBUTYRATE (GHB) AND -BUTYROLACTONE (GBL) IN LIQUIDS PERFORMED AT NATIONAL LABORATORY OF FORENSIC SCIENCE (SKL), SWEDEN
ANALYSIS OF -HYDROXYBUTYRATE (GHB) AND -BUTYROLACTONE (GBL) IN LIQUIDS PERFORMED AT NATIONAL LABORATORY OF FORENSIC SCIENCE (SKL), SWEDEN Per LUNDQUIST National Laboratory of Forensic Science, Linköping,
More informationab Hemoglobin Assay Kit (Colorimetric)
Version 1 Last updated 8 May 2018 ab234046 Hemoglobin Assay Kit (Colorimetric) For the measurement of hemoglobin in various biological samples. This product is for research use only and is not intended
More informationGuidelines for Troubleshooting and Maintenance of AA Systems. Presented by Eric Vanclay, Atomic Spectroscopy Consumables Product Manager
Guidelines for Troubleshooting and Maintenance of AA Systems Presented by Eric Vanclay, Atomic Spectroscopy Consumables Product Manager Common AA Problems Reported by Customers Sensitivity: Sensitivity
More informationIntegration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation
PO-CON69E Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation MSACL 6 EU Stéphane Moreau, Daisuke Kawakami, Toshikazu Minohata Shimadzu Europe GmbH, Duisburg,
More informationNeedle Valves Catalog 4110-NV December 2010
Needle Valves Catalog 4110-NV December 2010 Series Needle Valves Catalog 4110-NV Introduction Parker Series nion onnet Valves have been engineered for use at pressures up to 6,000 (414 bar) and temperatures
More informationElcometer 138/2. Surface Contamination Kit. Operating Instructions
Elcometer 138/2 English Surface Contamination Kit Operating Instructions R English is a registered trademark of Elcometer Limited. All other trademarks acknowledged. Copyright Elcometer Limited. 2010.
More informationOrganophosphorus Pesticides Analysis Using an Agilent J&W DB-5ms Ultra Inert Capillary GC Column. Application Note. Environmental. Abstract.
Organophosphorus Pesticides Analysis Using an Agilent J&W DB-5ms Ultra Inert Capillary GC Column Application Note Environmental Authors Doris Smith and Kenneth Lynam Agilent Technologies, Inc. 2850 Centerville
More informationMinimally Invasive. TEM Instrument System for Transanal Endoscopic Microsurgery
TEM Minimally Invasive TEM Instrument System for Transanal Endoscopic Microsurgery The only complete system for transanal endoscopic microsurgery Unique autoclavable stereoscope for 3-D visualization of
More informationNeedle Valves. We deliver confidence through quality products
We deliver confidence through quality products INTRODUCTION NEEDLE VALVES SD range of Needle valves come in various sizes, sealing styles, end connections and stem types. They are available in bar stock
More information