1 The use of cone-beam computed tomography in dentistry : An advisory statement from the American Dental Association Council on Scientific Affairs The American Dental Association Council on Scientific Affairs JADA 2012;143(8): The following resources related to this article are available online at jada.ada.org ( this information is current as of August 15, 2012): Updated information and services including high-resolution figures, can be found in the online version of this article at: This article cites 8 articles, 2 of which can be accessed free: Information about obtaining reprints of this article or about permission to reproduce this article in whole or in part can be found at: Downloaded from jada.ada.org on August 15, 2012 Reproduction or republication strictly prohibited without prior written permission of the American Dental Association.

2 The use of cone-beam computed tomography in dentistry An advisory statement from the American Dental Association Council on Scientific Affairs The American Dental Association Council on Scientific Affairs The emergence of cone-beam computed tomography (CBCT) has expanded the field of oral and maxillofacial radiology. CBCT imaging provides three-dimensional volumetric data construction of dental and associated maxillofacial structures with isotropic resolution and high dimensional accuracy. A CBCT scanner uses a collimated x-ray source that produces a cone- or pyramid-shaped beam of x- radiation, which makes a single full or partial circular revolution around the patient, producing a sequence of discrete planar projection images using a digital detector. These two-dimensional images are reconstructed into a three-dimensional volume that can be viewed in a variety of ways, including cross-sectional images and volume renderings of the oral anatomy. Although CBCT units produce a higher radiation dose than one would receive from a single traditional dental radiograph, the radiation dose delivered typically is less than that produced during a medical multichannel computed tomographic scan. CBCT radiation doses also vary widely according to the device used, x-ray energy and filtration, tolerance for image noise and motion artifacts, and the size of the imaging area (field of view [FOV]) that is used to acquire volumetric data 1-3 (Table, 2,4,5 page 901). Since CBCT devices were introduced commercially in the United States in 2001, dentists have come to use the technology in increasing numbers. Yet, A B S T R A C T Background and Overview. The American Dental Association Council on Scientific Affairs (CSA) promotes safe use of conebeam computed tomography (CBCT) and appropriate professional justification of CBCT imaging procedures. The CSA reviewed the current research literature to develop collaborative guidance regarding the use of CBCT in dentistry with input from a broad group of stakeholder organizations. The Council s principles for CBCT safety may be applied to any number of potential dental CBCT imaging applications. Practice Implications. As with other radiographic modalities, CBCT imaging should be used only after a review of the patient s health and imaging history and the completion of a thorough clinical examination. Dental practitioners should prescribe CBCT imaging only when they expect that the diagnostic yield will benefit patient care, enhance patient safety or improve clinical outcomes significantly. Key Words. Radiation protection; professional practice; dental radiography; cone-beam computed tomography. JADA 2012;143(8): Address reprint requests to the Council on Scientific Affairs, American Dental Association, 211 E. Chicago Ave., Chicago, Ill JADA 143(8) August

3 although CBCT technologies have advanced rapidly across time, concerns have been expressed about whether the information acquired with CBCT imaging warrants the additional exposure risk, as well as about the level of training, education and experience required to interpret the CBCT data set. 1 To provide guidance on CBCT imaging, national and international groups have prepared basic principles, 1 position statements 6,7 and professional guidelines for CBCT use. 4,8 Recommendations for adequate operator education regarding use and interpretation of CBCT imaging also have been published. 1,6 In addition, CBCT guidance documents are being developed by dental specialty organizations. 9 As with any clinical guidance regarding the acquisition of diagnostic information, dentists must keep in mind their primary ethical obligation to protect patients from harm. Consistent with its mission to serve as a primary resource on the science of dentistry, the ADA Council on Scientific Affairs (CSA) reviewed the current science, guidance and other resources available from professional organizations to prepare this advisory statement of principles for the safe use of CBCT in dentistry. The Council then sought comments and input from a range of stakeholder organizations (listed in the acknowledgments at the end of this article) to develop this collaborative guidance statement for the profession. PRINCIPLES FOR THE SAFE USE OF DENTAL AND MAXILLOFACIAL CONE- BEAM COMPUTED TOMOGRAPHY The Council recommends adherence to the following principles for the safe and appropriate use of CBCT in clinical practice. das with other radiographic modalities, CBCT imaging should be used only after a review of the patient s health and imaging history and completion of a thorough clinical examination. din accordance with the National Council on Radiation Protection & Measurements 10 (NCRP s) Report No. 145 and standard selection criteria for dental radiographs, 11 clinicians should perform radiographic imaging, including CBCT, only after professional justification that the potential clinical benefits will outweigh the risks associated with exposure to ionizing radiation. All radiographic examinations should be indicated clinically and justified appropriately, and such examinations should not be performed for screening purposes. Additional considerations should be weighed prior to the exposure of children and adolescents. These patients are more radiosensitive (that is, their cancer risk per unit dose of ionizing radiation is higher), and they have a longer lifetime risk of developing radiation-induced cancers. 12,13 dthe clinician should prescribe traditional dental radiographs and CBCT scans only when he or she expects that the diagnostic yield will benefit patient care, enhance patient safety, significantly improve clinical outcomes or all of these. dcbct should be considered as an adjunct to standard oral imaging modalities. CBCT may supplement or replace conventional (twodimensional or panoramic) dental radiography for the diagnosis, monitoring and treatment of oral disease or the management of oral conditions when, in the clinician s decision-making process, he or she determines that oral anatomical structures of interest may not be captured adequately by means of conventional radiography. din accordance with the as-low-as-reasonablyachievable (ALARA) principle, radiation dose for dental patients should be optimized to achieve the lowest practical level to address a specific clinical situation. (Author s note: Dose optimization means delivering a radiation dose to the organs and tissues of clinical interest no greater than that required for adequate imaging and minimizing the dose to other structures. The patient s radiation dose is considered to be optimized when imaging is performed with the least amount of radiation required to provide adequate image quality. The goal of every imaging procedure is to provide images adequate for the clinical purpose. What constitutes adequate image quality depends on the modality being used and the clinical question being asked.) The clinician should limit the radiation dose for CBCT scans by optimizing image quality, using the smallest FOV necessary for imaging a specific anatomical area of interest and using the lowest combination of tube output and scan time (in milliamperes) consistent with adequate image noise content and motion artifact. dcbct operators should take every precaution to reduce radiation dose and ensure the patient s safety during CBCT imaging. The use of thyroid collars and lead aprons is recommended in the NCRP s 10 radiation safety guid- ABBREVIATION KEY. ADA: American Dental Association. ALARA: As low as reasonably achievable. CBCT: Cone-beam computed tomography. CSA: Council on Scientific Affairs. FOV: Field of view. NCRP: National Council on Radiation Protection & Measurements. 900 JADA 143(8) August 2012

4 TABLE Effective dose estimates for common dental radiographic examinations and cone-beam computed tomographic (CBCT) imaging.* ance for the dental profession. However, it is neither possible nor desirable to use these protective devices in all clinical situations, especially in cases in which the collar or apron may obstruct the area of interest. Protective thyroid collars and lead aprons should be used when they will not interfere with the examination. da CBCT examination should be prescribed by a dentist who has appropriate training and education in CBCT imaging, including an understanding of the significance of CBCT selection and imaging findings. dcbct images of the oral and maxillofacial structures that are the subject of the CBCT examination should be evaluated by a dentist with appropriate training and education in CBCT interpretation. (Author s note: Establishing formal standards for CBCT training and education is beyond the scope of this CSA advisory statement. The Council will share the statement with the Commission on Dental Accreditation and other educational groups for further consideration.) dregardless of the primary purpose for the selection of CBCT, the complete image data set must be interpreted by an appropriately qualified health care provider (such as a dentist or a physician). The prescribing clinician should receive a thorough radiological report. If the prescriber also interprets the CBCT images, he or she should enter the findings into the patient record and communicate them appropriately to the patient or, if the patient is a minor, to the patient s parent or legal guardian. ddental practitioners who use CBCT devices must receive appropriate training and education in the safe use of CBCT imaging systems. Although there may be instances in which training provided by vendors of CBCT systems is appropriate, dental practitioners should consider the source of the information concerning radiation safety. The Council encourages CBCT operators to participate in continuing education courses to maintain adequate knowledge regarding radiation protection in the dental care setting. IMAGING TECHNIQUE EFFECTIVE DOSE Conventional Radiography Four-image posterior bitewings with photo-stimulable phosphor (PSP) 5.0 or F-speed film and rectangular collimation Panoramic radiograph with charge-coupled device Cephalometric radiograph, posteroanterior or lateral with PSP Full-mouth radiographs With PSP storage or F-speed film and rectangular collimation 34.9 With PSP or F-speed film and round collimation CBCT Dentoalveolar CBCT (small and medium field of view [FOV]) (61) Maxillofacial CBCT (large FOV) (87) * Estimates for adult patients based on data from Pauwels and colleagues, 2 The SEDENTEXCT Project 4 and Ludlow and colleagues. 5 Measured in microsieverts. Median values for effective dose provided parenthetically. ddentists must abide by applicable federal and state regulations in the provision of dental imaging modalities. This includes following regulations or guidance to ensure a safe working environment for both the staff and the public in relation to CBCT equipment and other sources of ionizing radiation. CBCT unit operators should contact state and local radiation control programs to verify any additional requirements for operation of CBCT, including applicable requirements for licensure or accreditation. ddentists should use professional judgment in the prescription and performance of CBCT examinations by consulting recommendations from available CBCT guidelines and by considering the specific clinical situation and needs of the individual patient. Given the ongoing development and research in this technology, dentists should stay abreast of the scientific literature and apply an evidence- and science-based approach to the use of CBCT. dthis advisory statement calls for appropriate agencies within the ADA and the dental community at large to develop and implement recommendations and criteria for adequate CBCT training and education of dentists or other CBCT unit operators. These recommendations should include but not be limited to patient evaluation, radiation protection, selection of appropriate CBCT imaging parameters, performance of the CBCT examination and image interpretation. The recommendations also must include requirements for predoctoral dental education programs and for continuing education coursework and training. dfacilities considering the installation of JADA 143(8) August

5 CBCT devices should consult a health physicist (or other qualified expert) to perform a shielding analysis based on NCRP reports 145 and ,14 dfacilities using CBCT systems should consult a health physicist (or other qualified expert) to perform equipment performance and compliance evaluations initially at installation and then follow a schedule in compliance with local, state and federal requirements. The Council recommends that a performance evaluation be completed at least annually. The evaluations should include patient dose estimation to assist the facility with patient dose management. dstaffs of facilities using CBCT should establish a quality control program. This program can be based on the manufacturer s recommendations or can be established, implemented and monitored by a qualified expert. SUMMARY CBCT technologies offer an advanced point-ofcare imaging modality that clinicians should use selectively as an adjunct to conventional dental radiography. The selection of CBCT for dental and maxillofacial imaging should be based on professional judgment in accordance with the best available scientific evidence, weighing potential patient benefits against the risks associated with the level of radiation dose. Clinicians must apply the ALARA principle in protecting patients and staff during the acquisition of CBCT images. This includes appropriate justification of CBCT use, optimizing technical factors, using the smallest FOV necessary for diagnostic purposes and using appropriate personal protective shielding. Disclosure. Members of the American Dental Association Council on Scientific Affairs (CSA) are required to maintain a current conflict-of-interest disclosure to participate in CSA activities. No potential conflicts of interest relevant to this statement were reported. The American Dental Association (ADA) Council on Scientific Affairs gratefully acknowledges Dr. John Ludlow, professor, School of Dentistry, University of North Carolina, Chapel Hill, and Dr. Sharon Brooks, professor emerita, School of Dentistry, University of Michigan, Ann Arbor, for their assistance in finalizing this advisory statement. The ADA expresses its appreciation to the following organizations for their significant contributions to the statement: the American Academy of Oral and Maxillofacial Pathology; the American Academy of Oral and Maxillofacial Radiology; the American Academy of Pediatric Dentistry; the American Academy of Periodontology; the American Association of Endodontists; the American Association of Oral and Maxillofacial Surgeons; the American Association of Orthodontists; the American Association of Physicists in Medicine; the Conference of Radiation Control Program Directors; the National Council on Radiation Protection & Measurements; and the U.S. Food and Drug Administration. 1. Horner K, Islam M, Flygare L, Tsiklakis K, Whaites EJ. Basic principles for use of dental cone beam computed tomography: consensus guidelines of the European Academy of Dental and Maxillofacial Radiology. Dentomaxillofac Radiol 2009;38(4): Pauwels R, Beinsberger J, Collaert B, et al; SEDENTEXCT Project Consortium. Effective dose range for dental cone beam computed tomography scanners. Eur J Radiol 2012;81(2): Ludlow JB, Ivanovic M. Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;106(1): The SEDENTEXCT Project. Radiation Protection: Cone Beam CT for Dental and Maxillofacial Radiology: Evidence Based Guidelines 2011 (v2.0 Final). Accessed May 11, Ludlow JB, Davies-Ludlow LE, White SC. Patient risk related to common dental radiographic examinations: the impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculation. JADA 2008;139(9): Carter L, Farman AG, Geist J, et al; American Academy of Oral and Maxillofacial Radiology. American Academy of Oral and Maxillofacial Radiology executive opinion statement on performing and interpreting diagnostic cone beam computed tomography. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;106(4): Joint Position Statement of the American Association of Endodontists and the American Academy of Oral and Maxillofacial Radiology. Use of cone-beam computed tomography in endodontics. paper_cb.pdf. Accessed July 10, Academy of Osseointegration guidelines of the Academy of Osseointegration for the provision of dental implants and associated patient care. Int J Oral Maxillofac Implants 2010;25(3): Scarfe WC. All that glitters is not gold : standards for conebeam computerized tomographic imaging (published online ahead of print Feb. 3, 2011). Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011;111(4): doi: /j.tripleo National Council on Radiation Protection & Measurements. Radiation Protection in Dentistry (Report No. 145). Bethesda, Md.: NRCP Publications; American Dental Association; U.S. Department of Health and Human Services. The Selection of Patients for Dental Radiographic Examinations. Chicago: American Dental Association; topics_radiography_examinations.pdf. Accessed May 11, National Research Council of The National Academies, Committee to Assess Health Risks from Exposure to Low Levels of Ionizing Radiation, Board of Radiation Effects Research, Division on Earth and Life Studies Health Risks From Exposure to Low Levels of Ionizing Radiation: BEIR VII phase 2. Washington: National Academy of Sciences, National Academies Press; International Commission on Radiological Protection. The 2007 Recommendations of the International Commission on Radiological Protection (publication 103). Ann ICRP 2007;37(2-4): National Council on Radiation Protection & Measurements. Structural Shielding Design for Medical Imaging Facilities (Report No. 147). Bethesda, Md.: NRCP Publications; JADA 143(8) August 2012

Managing Cone Beam CT Dose in Paediatric Dental Imaging

Managing Cone Beam CT Dose in Paediatric Dental Imaging Ask EuroSafe Imaging Tips & Tricks Paediatric Imaging Working Group Managing Cone Beam CT Dose in Paediatric Dental Imaging Raija Seuri (HUS Medical Imaging Center, FI) Cristina Almeida (Centro Hospitalar

More information

The Role of. 54 MARCH 2016 // dentaltown.com. radiology feature. by Deepak Gupta, MDS

The Role of. 54 MARCH 2016 // dentaltown.com. radiology feature. by Deepak Gupta, MDS The Role of Imaging by Deepak Gupta, MDS Dr. Deepak Gupta completed his post graduation in oral medicine and maxillofacial radiology in 2011. He is currently an Associate Professor/ Reader in the Department

More information

STANDARD OF PRACTICE. Dental CT Scanners CONTENTS. April 2011

STANDARD OF PRACTICE. Dental CT Scanners CONTENTS. April 2011 April 2011 STANDARD OF PRACTICE Approved by Council April 18, 2011 Dental CT Scanners This document is the standard of practice in relation to the use of dental computed tomography (CT) scanners with respect

More information

SUMMARY AND EXTRACTS FROM THE 2010 GUIDANCE ON THE SAFE USE OF DENTAL CONE BEAM CT (COMPUTED TOMOGRAPHY) EQUIPMENT

SUMMARY AND EXTRACTS FROM THE 2010 GUIDANCE ON THE SAFE USE OF DENTAL CONE BEAM CT (COMPUTED TOMOGRAPHY) EQUIPMENT SUMMARY AND EXTRACTS FROM THE 2010 GUIDANCE ON THE SAFE USE OF DENTAL CONE BEAM CT (COMPUTED TOMOGRAPHY) EQUIPMENT The use of dental CBCT equipment must comply with all the regulations (IRR99 and IR(ME)R2000)

More information

Agenda: Dental Cone Beam Imaging

Agenda: Dental Cone Beam Imaging Cone Beam Imaging Agenda: Dental Cone Beam Imaging *Definition and Functionality *Usage and diagnostics benefits *Comparative radiation information *Federal regulatory responsibilities: manufacturing *State

More information

Dental ConeBeam Computed Tomography (CBCT) X-ray Systems

Dental ConeBeam Computed Tomography (CBCT) X-ray Systems Dental ConeBeam Computed Tomography (CBCT) X-ray Systems PROPOSED REVISIONS TO 4732.XXXX, 1.0 4732.#### DENTAL CONEBEAM COMPUTED TOMOGRAPHY (CBCT) X-RAY SYSTEMS; STATIONARY AND MOBILE. Subpart 1. Applicability.

More information

Johan Hartshorne 1. Summary. Introduction

Johan Hartshorne 1. Summary. Introduction R E V I E W A R T I C L E Essential guidelines for using cone beam computed tomography (CBCT) in implant dentistry. Part 3: Radiation dose, risks, safety, ethical and medico-legal considerations Johan

More information

CT Quality Control Manual FAQs

CT Quality Control Manual FAQs CT Quality Control Manual FAQs General Question: How often will the QC Manual be updated and how will those updates be communicated? Answer: The ACR CT Physics Subcommittee will review any comments, issues

More information

The Practice Standards for Medical Imaging and Radiation Therapy. Sonography Practice Standards

The Practice Standards for Medical Imaging and Radiation Therapy. Sonography Practice Standards The Practice Standards for Medical Imaging and Radiation Therapy Sonography Practice Standards 2017 American Society of Radiologic Technologists. All rights reserved. Reprinting all or part of this document

More information

Comparison of adsorbed skin dose received by patients in cone beam computed tomography, spiral and conventional computed tomography scanninng

Comparison of adsorbed skin dose received by patients in cone beam computed tomography, spiral and conventional computed tomography scanninng (1390 3 24 ) 3 3 2 - - - 1-1 -2-3 Comparison of adsorbed skin dose received by patients in cone beam computed tomography, spiral and conventional computed tomography scanninng Ghazi Khanlou Sani K 1, Eskandarlou

More information

Dental Radiography Core Subject. Digital Radiography

Dental Radiography Core Subject. Digital Radiography Dental Radiography Core Subject Digital Radiography Aims: To develop an understanding of the history of digital radiography, the different types of digital x-rays and the advantages and disadvantages of

More information

Prepublication Requirements

Prepublication Requirements Issued Prepublication Requirements Standards Revisions for Organizations Providing Fluoroscopy Services The Joint Commission has approved the following revisions for prepublication. While revised requirements

More information

Radiation Safety & Determining Need for Radiographs

Radiation Safety & Determining Need for Radiographs Radiation Safety & Determining Need for Radiographs Guidelines for Radiographic Examination All radiation is harmful! These guidelines have been established to protect the patient and operator from unnecessary

More information

Current Concepts in Caries Management Diagnostic, Treatment and Ethical/Medico-Legal Considerations. Radiographic Caries Diagnosis

Current Concepts in Caries Management Diagnostic, Treatment and Ethical/Medico-Legal Considerations. Radiographic Caries Diagnosis Current Concepts in Caries Management Diagnostic, Treatment and Ethical/Medico-Legal Considerations Richard N. Bohay, DMD, MSc, MRCDC Associate Professor, Schulich School of Medicine & Dentistry Schulich

More information

User Guide for Dental and Maxillofacial Cone Beam Computed Tomography (CBCT)

User Guide for Dental and Maxillofacial Cone Beam Computed Tomography (CBCT) User Guide for Dental and Maxillofacial Cone Beam Computed Tomography (CBCT) Poster No.: C-0756 Congress: ECR 2014 Type: Educational Exhibit Authors: J. Ukkonen, J. Asp; Helsinki/FI Keywords: Education

More information

Kodak Dental Radiography Series. Radiation Safety in Dental Radiography. Dental

Kodak Dental Radiography Series. Radiation Safety in Dental Radiography. Dental Kodak Dental Radiography Series Radiation Safety in Dental Radiography Dental Radiation Safety in Dental Radiography The goal of dental radiography is to obtain diagnostic information while keeping the

More information

Two-dimensional (2D) images have provided. Cone Beam Computed Tomography in Dentistry: What Dental Educators and Learners Should Know

Two-dimensional (2D) images have provided. Cone Beam Computed Tomography in Dentistry: What Dental Educators and Learners Should Know Cone Beam Computed Tomography in Dentistry: What Dental Educators and Learners Should Know Shawn Adibi, D.D.S., F.D.O.C.S., M.Ed.; Wenjian Zhang, D.D.S., M.S., Ph.D.; Tom Servos, D.D.S.; Paula N. O Neill,

More information

A Cone Beam Computed Tomography Study Among Dental Residents Based on a Questionnaire

A Cone Beam Computed Tomography Study Among Dental Residents Based on a Questionnaire A Cone Beam Computed Tomography Study Among Dental Residents Based on a Questionnaire Alexandra Mihaela Stoica, Assistant Lecturer, DMD Monica Monea, Associate Prof., DMD, PhD Dragos Dan Sita, Assistant

More information

BRITISH SOCIETY OF DENTAL AND MAXILLOFACIAL RADIOLOGY CORE CURRICULA IN DENTAL RADIOGRAPHY AND RADIOLOGY FOR THE DENTAL TEAM

BRITISH SOCIETY OF DENTAL AND MAXILLOFACIAL RADIOLOGY CORE CURRICULA IN DENTAL RADIOGRAPHY AND RADIOLOGY FOR THE DENTAL TEAM BRITISH SOCIETY OF DENTAL AND MAXILLOFACIAL RADIOLOGY CORE CURRICULA IN DENTAL RADIOGRAPHY AND RADIOLOGY FOR THE DENTAL TEAM 2015 0 INTRODUCTION The original core curriculum in Dental Radiography and Radiology

More information

Dental Radiography Series

Dental Radiography Series Dental Radiography Series Guidelines for prescribing dental radiographs. Background Radiological s are used to discover and define the type and extent of disease in many clinical situations. However, public

More information

The College of Dental Surgeons of Saskatchewan Radiation and Imaging Standard

The College of Dental Surgeons of Saskatchewan Radiation and Imaging Standard The College of Dental Surgeons of Saskatchewan Radiation and Imaging Standard Legislation Radiation safety has long been a priority in Saskatchewan. This province, the first in Canada to have radiation

More information

Awareness and Attitude among Dental Professional towards CBCT

Awareness and Attitude among Dental Professional towards CBCT IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861. Volume 10, Issue 5 (Sep.- Oct. 2013), PP 55-59 Awareness and Attitude among Dental Professional towards CBCT

More information

Dental Intraoral X-ray Systems

Dental Intraoral X-ray Systems Dental Intraoral X-ray Systems PROPOSED REVISIONS TO 4732.XXXX, 2.0 4732.#### DENTAL INTRAORAL X-RAY SYSTEMS; STATIONARY AND MOBILE. Commented [JC(1]: Based on part 4732.0880. Subpart 1. Applicability.

More information

Assessment of Response of Dental Clinicians and Patients towards Different Imaging Modalities Used In Diagnostic Evaluation of Dental Implant Therapy.

Assessment of Response of Dental Clinicians and Patients towards Different Imaging Modalities Used In Diagnostic Evaluation of Dental Implant Therapy. Assessment of Response of Dental Clinicians and Patients towards Different Imaging Modalities Used In Diagnostic Evaluation of Dental Implant Therapy. Khairnar Mayur Sudhakar, Raut Darshana Hemant, Bakshi

More information

ASRT Position Statements

ASRT Position Statements ASRT Position Statements Effective June 25, 2017 Contents Collective Bargaining Units... 1 Conjoint Evaluation of Educational Programs... 1 Degree Requirements for Medical Imaging and Radiation Therapy

More information

Current status of diagnostic imaging in dental university hospitals in Japan

Current status of diagnostic imaging in dental university hospitals in Japan Oral Radiol (2004) 20:15 21 Japanese Society for Oral and Maxillofacial Radiology and Springer-Verlag Tokyo 2004 DOI 10.1007/s11282-004-0010-3 ORIGINAL ARTICLE Takehito Sasaki Minoru Fujita Tsuguhisa Katoh

More information

Head to new heights with your imaging SCANORA 3D

Head to new heights with your imaging SCANORA 3D SCANORA 3D Head to new heights with your imaging Benefits at a glance The solution for dentomaxillofacial and ENT imaging Easy Patient seated for added stability during exposure. Clear, self-explinatory

More information

Factors determining Radiation Protection Practices among Indian General Dental Practitioners: An Explorative Study

Factors determining Radiation Protection Practices among Indian General Dental Practitioners: An Explorative Study wjd Almas Binnal et al ORIGINAL RESEARCH 10.5005/jp-journals-10015-1404 Factors determining Radiation Protection Practices among Indian General Dental Practitioners: An Explorative Study 1 Almas Binnal,

More information

ISSN (Print) Original Research Article

ISSN (Print) Original Research Article Scholars Journal of Dental Sciences (SJDS) Sch. J. Dent. Sci., 2017; 4(11):491-495 Scholars Academic and Scientific Publisher (An International Publisher for Academic and Scientific Resources) www.saspublisher.com

More information

Perception of dental undergraduates and interns on radiation protection safety protocol - A questionnaire based crosssectional

Perception of dental undergraduates and interns on radiation protection safety protocol - A questionnaire based crosssectional Original Research Article Perception of dental undergraduates and interns on radiation protection safety protocol - A questionnaire based crosssectional study Sonia Behal * Reader, Oral Medicine and Radiology,

More information

Downloaded from jdm.tums.ac.ir at 9:49 IRDT on Wednesday March 27th 2019 *** ****

Downloaded from jdm.tums.ac.ir at 9:49 IRDT on Wednesday March 27th 2019 *** **** CB **** -*** -** -* ** *** **** itle: Comparison of radiation absorbed dose in target organs in maxillofacial imaging with panoramic, conventional linear tomography, cone beam computed tomography and computed

More information

5.I.1. GENERAL PRACTITIONER ANNOUNCEMENT OF CREDENTIALS IN NON-SPECIALTY INTEREST AREAS

5.I.1. GENERAL PRACTITIONER ANNOUNCEMENT OF CREDENTIALS IN NON-SPECIALTY INTEREST AREAS Report of the Council on Ethics, Bylaws and Judicial Affairs on Advisory Opinion 5.I.1. GENERAL PRACTITIONER ANNOUNCEMENT OF CREDENTIALS IN NON-SPECIALTY INTEREST AREAS Ethical Advertising under ADA Code:

More information

Test Bank CHAPTER 1. Multiple Choice. 1. Who was awarded the first Nobel Prize for physics in 1901, for his experimental work with. radiation?

Test Bank CHAPTER 1. Multiple Choice. 1. Who was awarded the first Nobel Prize for physics in 1901, for his experimental work with. radiation? Test Bank CHAPTER 1 Multiple Choice 1. Who was awarded the first Nobel Prize for physics in 1901, for his experimental work with radiation? a. W. J. Morton b. O. Walkhoff c. W. D. Coolidge d. W. C. Roentgen

More information

Current situation of cone beam computed tomography in dentomaxillofacial radiology education.

Current situation of cone beam computed tomography in dentomaxillofacial radiology education. Biomedical Research 2017; 28 (11): 5014-5019 ISSN 0970-938X www.biomedres.info Current situation of cone beam computed tomography in dentomaxillofacial radiology education. Nilufer Ersan *, Erdogan Fisekcioglu,

More information

RADIATION PROTECTION IN DENTISTRY AND ORAL AND MAXILLOFACIAL IMAGING

RADIATION PROTECTION IN DENTISTRY AND ORAL AND MAXILLOFACIAL IMAGING NCRP DRAFT SC 4-5 REPORT RADIATION PROTECTION IN DENTISTRY AND ORAL AND MAXILLOFACIAL IMAGING Note: Copyright permission is being sought for the figures and tables requiring such permission prior to their

More information

Summary at End of the Project, June 2011

Summary at End of the Project, June 2011 Summary at End of the Project, June 2011 1.1 Project context and objectives The SEDENTEXCT project (1 January 2008 30 June 2011) focused on enhanced safety and efficacy in the use of Cone Beam Computed

More information

Appendix I. List of stakeholders consulted with on the Patient Radiation Protection Manual and members of the Medical Exposure Radiation Unit

Appendix I. List of stakeholders consulted with on the Patient Radiation Protection Manual and members of the Medical Exposure Radiation Unit References References The accuracy, quality and relevance of these works are not guaranteed or uniform and more recent information may have superseded these works. This list is not exhaustive. It does

More information

Facing the challenges: IAEA activities to protect the patients

Facing the challenges: IAEA activities to protect the patients Facing the challenges: IAEA activities to protect the patients Debbie Gilley Radiation Protection of Patients Radiation Safety and Monitoring Section Division of Radiation, Transport and Waste Safety 18

More information

Using cone beam technology in orthodontics

Using cone beam technology in orthodontics PRACTICE US Using cone beam technology in orthodontics Continuing education earn 2 ce credits! Edward Lin explains the benefits of adding cone beam technology to the orthodontic armamentaria Since cone

More information

The IAC Standards and Guidelines for Dental CT Accreditation

The IAC Standards and Guidelines for Dental CT Accreditation The IAC Standards and Guidelines for Dental CT Accreditation Table of Contents All entries in Table of Contents are linked to the corresponding sections. Introduction... 3 Part A: Organization... 4 Section

More information

Code of Practice for Radiation Protection in Dentistry. Code of Practice For Radiation Protection in Dentistry

Code of Practice for Radiation Protection in Dentistry. Code of Practice For Radiation Protection in Dentistry Code of Practice for Radiation Protection in Dentistry Code of Practice For Radiation Protection in Dentistry 10 OCTOBER 2017 CONTENTS 1. INTRODUCTION... 3 1.0 CITATION... 3 1.1 BACKGROUND... 3 1.2 PURPOSE

More information

IONISING RADIATION REGULATIONS 99

IONISING RADIATION REGULATIONS 99 IONISING RADIATION REGULATIONS 99 & IRMER IONISING RADIATION MEDICAL EXPOSURE REGULATIONS BARBARA LAMB Specialist Radiographer Dental and maxillofacial radiography BarbaraHLamb@googlemail.com 07775994424

More information

CT Dose Reduction in Pediatric Patients

CT Dose Reduction in Pediatric Patients CT Dose Reduction in Pediatric Patients By Kelly Firestine, RT(R)(CT)(M) Executive Summary CT is an incredibly valuable imaging tool, but there are unique concerns with pediatric patients, including the

More information

The Practice Standards for Medical Imaging and Radiation Therapy

The Practice Standards for Medical Imaging and Radiation Therapy The Practice Standards for Medical Imaging and Radiation Therapy Advisory Opinion Statement Use of Post-Exposure Shuttering, Cropping and Electronic Masking in Radiography 2018 American Society of Radiologic

More information

NEW JERSEY RADIOLOGIC TECHNOLOGY BOARD OF EXAMINERS (BOARD) DENTAL RADIOGRAPHY CURRICULUM REQUIREMENTS GENERAL REQUIREMENTS

NEW JERSEY RADIOLOGIC TECHNOLOGY BOARD OF EXAMINERS (BOARD) DENTAL RADIOGRAPHY CURRICULUM REQUIREMENTS GENERAL REQUIREMENTS CHRIS CHRISTIE DEPARTMENT OF ENVIRONMENTAL PROTECTION BOB MARTIN Governor Division of Environmental Safety and Health Commissioner Bureau of X-Ray Compliance, Technologist Certification Section KIM GUADAGNO

More information

Multislice CT versus cone beam CT: dosimetric and image quality comparision.

Multislice CT versus cone beam CT: dosimetric and image quality comparision. Multislice CT versus cone beam CT: dosimetric and image quality comparision. Poster No.: C-2589 Congress: ECR 2015 Type: Authors: Scientific Exhibit C. Dionisi 1, A. Crispo 2, E. Stefani 3, A. Lovaglio

More information

NEW JERSEY RADIOLOGIC TECHNOLOGY BOARD OF EXAMINERS (BOARD) DENTAL RADIOGRAPHY CURRICULUM REQUIREMENTS

NEW JERSEY RADIOLOGIC TECHNOLOGY BOARD OF EXAMINERS (BOARD) DENTAL RADIOGRAPHY CURRICULUM REQUIREMENTS CHRIS CHRISTIE DEPARTMENT OF ENVIRONMENTAL PROTECTION BOB MARTIN Governor Division of Environmental Safety and Health Commissioner Bureau of X-Ray Compliance, Technologist Certification Section KIM GUADAGNO

More information

Limited X-ray Machine Operator (LXMO) Curriculum Analysis

Limited X-ray Machine Operator (LXMO) Curriculum Analysis Program Number Program Name Date / /20 Limited X-ray Machine Operator (LXMO) Curriculum Analysis DIRECTIONS: Determine the course(s) in which each of the following content area is covered and enter the

More information

TEST GDP DCP. Dental Hygienists and Therapists. Radiography and Radiation Protection. Radiography and Radiation Protection IR(ME)R 2000

TEST GDP DCP. Dental Hygienists and Therapists. Radiography and Radiation Protection. Radiography and Radiation Protection IR(ME)R 2000 Radiography and Radiation Protection IR(ME)R 2000 J Makdissi DDS IQE MMedSc FDSRCS(Eng.) DDRRCR Clinical Senior Lecturer and Honorary Consultant Dental and Maxillofacial Radiology GDP a) Radiation physics

More information

Dental Extraoral X-ray Systems

Dental Extraoral X-ray Systems Dental Extraoral X-ray Systems PROPOSED REVISIONS TO 4732.XXXX, 1.0 4732.#### DENTAL EXTRAORAL X-RAY SYSTEMS; STATIONARY AND MOBILE. Subpart 1. Applicability. A registrant s x-ray system used for dental

More information

Cone Beam Computed Tomography (CBCT) and Digital Radiographies Requested and Related Factors by Iranian General Dentists

Cone Beam Computed Tomography (CBCT) and Digital Radiographies Requested and Related Factors by Iranian General Dentists Journal of Research in Medical and Dental Science 2018, Volume 6, Issue 4, Page No: 12-17 Copyright CC BY-NC 4.0 Available Online at: www.jrmds.in eissn No. 2347-2367: pissn No. 2347-2545 Cone Beam Computed

More information

International Journal of Radiation Research, January 2017

International Journal of Radiation Research, January 2017 Downloaded from ijrr.com at : +0330 on Tuesday November th Volume 5, No International Journal of Radiation Research, January 7 Radiation dose to the thyroid, eyes and parotid glands of patients undergoing

More information

3D Imaging: The Path to the Future of Dentistry (16DS004)

3D Imaging: The Path to the Future of Dentistry (16DS004) Email @ Conflict of Interest First Name MI Last Name Jr. / Sr. In accordance with the ADA CERP Standard V., everyone involved in planning or presenting this educational activity will be required to disclose

More information

Dental Radiography STANDARDS & GUIDELINES TABLE OF CONTENTS. College of Dental Surgeons of BC

Dental Radiography STANDARDS & GUIDELINES TABLE OF CONTENTS. College of Dental Surgeons of BC STANDARDS & GUIDELINES Dental Radiography TABLE OF CONTENTS Standards and guidelines inform practitioners and the public of CDSBC s expectations for registrants. This document primarily contains guidelines

More information

created by high-voltage devices Examples include medical and dental x-rays, light, microwaves and nuclear energy

created by high-voltage devices Examples include medical and dental x-rays, light, microwaves and nuclear energy What is radiation? Radiation is energy emitted from a source, that travels through space and can penetrate matter. Listed below are two types that we are exposed to and contribute to our overall radiation

More information

Policy Statement on Thyroid Shielding During Diagnostic Medical and Dental Radiology. American Thyroid Association

Policy Statement on Thyroid Shielding During Diagnostic Medical and Dental Radiology. American Thyroid Association Policy Statement on Thyroid Shielding During Diagnostic Medical and Dental Radiology American Thyroid Association June 2012 TABLE OF CONTENTS EXECUTIVE SUMMARY... 3 I. INTRODUCTION... 5 II. MAMMOGRAPHY...

More information

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION

Managing Patient Dose in Computed Tomography (CT) INTERNATIONAL COMMISSION ON RADIOLOGICAL PROTECTION Managing Patient Dose in Computed Tomography (CT) International Commission on Radiological Protection Information abstracted from ICRP Publication 87 Available at www.icrp.org Task Group: M.M. Rehani,

More information

CBCT Specific Guidelines for South African Practice as Indicated by Current Literature:

CBCT Specific Guidelines for South African Practice as Indicated by Current Literature: CBCT Specific Guidelines for South African Practice as Indicated by Current Literature: CF Hoogendijk Maxillo- facial and Oral surgery: Trauma: 1. Facial trauma for the confirmation or exclusion of fractures

More information

New York Radiation Health and Safety (NYR)

New York Radiation Health and Safety (NYR) New York Radiation Health and Safety (NYR) Exam Outline and Suggested References State Regulations Each state s dental board implements regulations and establishes rules for delegating legally allowable

More information

icat Precise Policy and Procedure Manual

icat Precise Policy and Procedure Manual ORAL SURGERY GROUP P.A. PRACTICE LIMITED TO ORAL AND MAXILLOFACIAL SURGERY DENTAL IMPLANTS, WISDOM TEETH, ORAL PATHOLOGY, AND ORAL MEDICINE Dr. David M. Rauch Dr. Philip S. Engel Dr. Richard K. Stern Dr.

More information

Effect of Spatial Position in the Field of View on Dimensional Changes in Cone Beam Computed Tomography

Effect of Spatial Position in the Field of View on Dimensional Changes in Cone Beam Computed Tomography Original Article Effect of Spatial Position in the Field of View on Dimensional Changes in Cone Beam Computed Tomography Mehrdad Panjnoush 1, Yasaman Kheirandish 2, Negar Zeini 3 1 Associate Professor,

More information

Evaluation of X-ray protective shielding used in dental offices in Kerman, Iran, in 2014

Evaluation of X-ray protective shielding used in dental offices in Kerman, Iran, in 2014 Received: 17 May 2016 Accepted: 3 Dec. 2016 Evaluation of X-ray protective shielding used in dental offices in Kerman, Iran, in 2014 Abstract Jahangir Haghani DDS, MSc 1, Maryam Raoof DDS, MSc 2, Maryam

More information

Life Science Journal 2014;11(6)

Life Science Journal 2014;11(6) Knowledge, Attitude and Perception among Egyptian Dental Undergraduates, Interns and Postgraduate Regard Biological Hazards and Radiologic Protection Techniques: A Questionnaire Based Cross-Sectional Study

More information

RECTANGULAR COLLIMATION

RECTANGULAR COLLIMATION A SPECIAL REPORT RECTANGULAR COLLIMATION No longer a matter of choice! Robert Langlais DDS MS FACD University of Texas San Antonio, Texas This Special Report is made available by Interactive Diagnostic

More information

AWARNESS TOWARDS RADIATION PROTECTION MEASURES AMONG DENTAL PRACTITIONERS IN COORG DISTRICT: A QUESTIONNAIRE STUDY

AWARNESS TOWARDS RADIATION PROTECTION MEASURES AMONG DENTAL PRACTITIONERS IN COORG DISTRICT: A QUESTIONNAIRE STUDY Original Article International Journal of Dental and Health Sciences Volume 02,Issue 06 AWARNESS TOWARDS RADIATION PROTECTION MEASURES AMONG DENTAL PRACTITIONERS IN COORG DISTRICT: A QUESTIONNAIRE STUDY

More information

IRMER Ionising Radiation Medical Exposure Regulations

IRMER Ionising Radiation Medical Exposure Regulations IRMER Ionising Radiation Medical Exposure Regulations Download for information at www.scottishdental.org IONISING RADIATION (MEDICAL EXPOSURE ) REGULATION 2000 (as Amended) (IR(ME)R AN EXPLANATION GUIDE

More information

Evaluation and Optimization of Exposure Index in Lumbar Spine and Pelvis X-Ray

Evaluation and Optimization of Exposure Index in Lumbar Spine and Pelvis X-Ray Evaluation and Optimization of Exposure Index in Lumbar Spine and Pelvis X-Ray Poster No.: C-1492 Congress: ECR 2012 Type: Scientific Exhibit Authors: R. M. Lopes, L. H. Domingos ; Mortágua/PT, Azoia de

More information

Dental Hygiene Spring 2018 Summer 2014 Fall COURSE OUTLINE DHT 1032 Dental Radiography 2 Credit Hours

Dental Hygiene Spring 2018 Summer 2014 Fall COURSE OUTLINE DHT 1032 Dental Radiography 2 Credit Hours COURSE OUTLINE DHT 1032 Dental Radiography 2 Credit Hours Course Description This course prepares the dental hygiene student to expose, process and critique intra and extraoral radiographs for clinical

More information

Multi-stakeholder meeting on the optimised use of CT scanners

Multi-stakeholder meeting on the optimised use of CT scanners Multi-stakeholder meeting on the optimised use of CT scanners The Process of CT dose optimisation through education and training and role of CT Manufacturers Dean Pekarovič EFRS - CT Expert Group EFRS

More information

Breast Tomosynthesis. What is breast tomosynthesis?

Breast Tomosynthesis. What is breast tomosynthesis? Scan for mobile link. Breast Tomosynthesis Breast tomosynthesis is an advanced form of mammography, a specific type of breast imaging that uses low-dose x-rays to detect cancer early when it is most treatable.

More information

Reduced Projection Algorithm for 2D Cephalograms Derived from 3D CBCT Images in Orthodontics

Reduced Projection Algorithm for 2D Cephalograms Derived from 3D CBCT Images in Orthodontics Reduced Projection Algorithm for 2D Cephalograms Derived from 3D CBCT Images in Orthodontics BY ABDELRAHMAN SALEM D.D.S., University of Jordan, Amman, Jordan 2009 THESIS Submitted as partial fulfillment

More information

Common Intra Oral Radiographic Errors Made by Dental Students

Common Intra Oral Radiographic Errors Made by Dental Students GMJ. 2013;2(2):44-48 Common Intra Oral Radiographic Errors Made by Dental Students Abdolaziz Haghnegahdar 1, Pegah Bronoosh 1, Mohamad Mehdi Taheri 2, Amin Farjood 2 1 Department of Oral and Maxillofacial

More information

Dental Cone Beam CT. What is Dental Cone Beam CT?

Dental Cone Beam CT. What is Dental Cone Beam CT? Scan for mobile link. Dental Cone Beam CT Dental cone beam computed tomography (CT) is a special type of x-ray equipment used when regular dental or facial x-rays are not sufficient. Your doctor may use

More information

CS 9300 Family. The power of flexibility

CS 9300 Family. The power of flexibility CS 9300 Family The power of flexibility The new CS 9300 digital imaging system from Carestream Dental take the guesswork out of examinations The all-in-one CS 9300 is the most versatile multimodality imaging

More information

Mastering Basic Skills Eases Conversion to Rectangular Collimation

Mastering Basic Skills Eases Conversion to Rectangular Collimation Mastering Basic Skills Eases Conversion to Rectangular Collimation Switching to Rectangular Collimation: First Know the Basics. Johan K. Aps, DDS, MSc, MSc, PhD Johan K. Aps, DDS, MSc, MSc, PhD -Special

More information

The use of ionizing radiation in medical and

The use of ionizing radiation in medical and SHORT COMMUNICATION Radiation protection guidelines for the practicing orthodontist Muralidhar Mupparapu Newark, NJ This article summarizes the most recent (December 2003) dental x-ray guidelines from

More information

Digital Implant Dentistry Workflow

Digital Implant Dentistry Workflow Digital Implant Dentistry Workflow Ahmad Kutkut, DDS, MS, FICOI, DICOI Director of Predoctoral Implant Program Chair UKCD Implant Board ahmad.kutkut@uky.edu Disclaimer Neither I or any of my immediate

More information

People Exposed to More Radiation from Medical Exams

People Exposed to More Radiation from Medical Exams People Exposed to More Radiation from Medical Exams With its release of a new report, titled Ionizing Radiation Exposure of the Population of the United States (Report No. 160, 2009), the National Council

More information

CT Scanning Protocol For V2R Guided Surgery Solutions

CT Scanning Protocol For V2R Guided Surgery Solutions CT Scanning Protocol For V2R Guided Surgery Solutions 2 V2R CT Scanning Protocol \\ Contents Contents General requirements... 3 V2R Dual Scan Protocol... 5 V2R Single Scan Protocol... 8 Overview... 10

More information

Mapping the ASRT Objectives for Radiation Protection (47 Objectives) and Radiation Biology (21 Objectives) to this Text

Mapping the ASRT Objectives for Radiation Protection (47 Objectives) and Radiation Biology (21 Objectives) to this Text Appendix B Mapping the ASRT Objectives for Radiation Protection (47 Objectives) and Radiation Biology (21 Objectives) to this Text 1. Identify and justify the need to minimize unnecessary radiation exposure

More information

Debra Pennington, MD Director of Imaging Dell Children s Medical Center

Debra Pennington, MD Director of Imaging Dell Children s Medical Center Debra Pennington, MD Director of Imaging Dell Children s Medical Center 1 Gray (Gy) is 1 J of radiation energy/ 1 kg matter (physical quantity absorbed dose) Diagnostic imaging doses in mgy (.001 Gy)

More information

CBCT: A dentist perspective

CBCT: A dentist perspective SEGi Review ISSN: 1985.5672 Vol.9, December 2015 CBCT: A dentist perspective Dr. Ranjana Garg, Faculty of Dentistry SEGi University. Dr. Vivek Vijay Gupta Faculty of Dentistry SEGi University Abstract

More information

Establishment of local diagnostic reference levels for quality control in intraoral radiography

Establishment of local diagnostic reference levels for quality control in intraoral radiography Oral Radiol (27) 33:38 44 DOI.7/s282-6-24-9 ORIGINAL ARTICLE Establishment of local diagnostic reference levels for quality control in intraoral radiography Maki Izawa Yasuo Harata Noriyoshi Shiba Nobuhide

More information

Patient dose assessment of CT perfusion scanning at the RSCH

Patient dose assessment of CT perfusion scanning at the RSCH Patient dose assessment of CT perfusion scanning at the RSCH Lesley Leavesley, Emma Whitehead, Matthew Pryor, Debbie Peet Regional Radiation Protection Service Royal Surrey County Hospital, Guildford Overview

More information

HDS PROCEDURE CODE GUIDELINES

HDS PROCEDURE CODE GUIDELINES D0100 - D0999 Clinical Oral Evaluations D0120 - D0180 The codes in this section have been revised to recognize the cognitive skills necessary for patient evaluation. The collection and recording of some

More information

Scope of Practice for the Diagnostic Ultrasound Professional

Scope of Practice for the Diagnostic Ultrasound Professional Scope of Practice for the Diagnostic Ultrasound Professional Copyright 1993-2000 Society of Diagnostic Medical Sonographers, Dallas, Texas USA: All Rights Reserved Worldwide. Organizations which endorse

More information

Radiation Dose Specification

Radiation Dose Specification Chapter 9 Dose Limits for Exposure to Ionizing Radiation Dose Limits for exposure to Ionizing Radiation apply to: Occupational workers Nonoccupational workers Radiation Dose Specification Equivalent Dose

More information

Chapter 10: Special Topics

Chapter 10: Special Topics Chapter 10: Special Topics Slide set of 71 slides based on the chapter authored by D. McLean and J. Shepherd of the publication (ISBN 978-92-0-131010-1): Diagnostic Radiology Physics: A Handbook for Teachers

More information

SEDENTEXCT: Guidelines and evidence-based use of CBCT

SEDENTEXCT: Guidelines and evidence-based use of CBCT : Guidelines and evidence-based use of CBCT Keith Horner John Dalton Rutherford Bragg UK largest single-site University 34,000 students University Dental Hospital of Manchester 90,000 patients attend

More information

Twelfth Annual Warren K. Sinclair Keynote Address

Twelfth Annual Warren K. Sinclair Keynote Address THE INFLUENCE OF NCRP ON RADIATION PROTECTION IN THE U.S.: REGULATION AND GUIDANCE Twelfth Annual Warren K. Sinclair Keynote Address Kenneth R. Kase Annual Meeting of NCRP 16 March 2015 1 OUTLINE Introduction

More information

X-RAY REGULATORY GUIDE

X-RAY REGULATORY GUIDE Minnesota Department of Health Radiation Control, X-ray Unit Protecting, maintaining and improving the health of all Minnesotans by promoting radiation safety through guidance and collaboration with the

More information

Thank You for Visiting Us at the Hawaii Dental Association Convention!

Thank You for Visiting Us at the Hawaii Dental Association Convention! February 2013 Help Us Help Our Members Find You! Register your office with information to help our HDS members find you! Specific information regarding your dental office will help members identify the

More information

Dosimetry of recently introduced CBCT Units for Oral and Maxillofacial Radiology

Dosimetry of recently introduced CBCT Units for Oral and Maxillofacial Radiology Dosimetry of recently introduced CBCT Units for Oral and Maxillofacial Radiology John B Ludlow, Laura E Davies-Ludlow, André Mol University of North Carolina, Chapel Hill, NC Background CBCT is seeing

More information

Proposed Radiation Safety Regulations: Submission form

Proposed Radiation Safety Regulations: Submission form Proposed Radiation Safety Regulations: Submission form Making a submission This form is designed to assist submitters responding to the discussion points in Proposed Radiation Safety Regulations: A consultation

More information

In the teaching of oral and maxillofacial medical imaging with CBCT technology.

In the teaching of oral and maxillofacial medical imaging with CBCT technology. Biomedical Research 2017; Special Issue: S90-S95 ISSN 0970-938X www.biomedres.info In the teaching of oral and maxillofacial medical imaging with CBCT technology. Jiameng Yu 1*, Li Yu 1, Benjuan Wei 1,

More information

Revised: 8/05; 9/08; 9/09; 8/11; 8/12; 1/13 Reviewed: 3/10

Revised: 8/05; 9/08; 9/09; 8/11; 8/12; 1/13 Reviewed: 3/10 DCH RADIOGRAPHY PROGRAM CURRICULUM 17 Hours of Pre-requisites are required before entering into the professional phase of the Radiography Program. Pre-requisites English Comp I Intermediate College Algebra

More information

organizations including the International Commission on Radiation Protection exposure dose management system to all the studies and

organizations including the International Commission on Radiation Protection exposure dose management system to all the studies and Background & Purpose Background Purpose As Through radiation this exposure research, in the we medical intend field to increases systematically worldwide, record efforts and are under manage way the to

More information

True Low Dose. Exact time to display image on screen may vary upon computer and network configuration.

True Low Dose. Exact time to display image on screen may vary upon computer and network configuration. RAYSCAN ALPHA PLUS True Low Dose Cone Beam CT Industry Leading Resolution High resolution images provide all the clinical information needed while keeping radiation exposure low. Endodontics - Smallest

More information

CT Imaging at the Point-of-Care

CT Imaging at the Point-of-Care ENGLISH True Dedication The new Planmed Verity Extremity CT Scanner revolutionizes extremity CT imaging. The compact unit brings 3D imaging at emergency departments, orthopedic clinics or trauma centers

More information

The knowledge of general dentists in Tabriz about using of digital radiography in dentistry

The knowledge of general dentists in Tabriz about using of digital radiography in dentistry Merit Research Journal of Medicine and Medical Sciences (ISSN: 2354-323X) Vol. 4(5) pp. 255-259, May, 2016 Available online http://www.meritresearchjournals.org/mms/index.htm Copyright 2016 Merit Research

More information