CSR-DAT. Implant system Key to implant codes Table of colour codes ZirTi surface. The Range CSR-DAT implants

Size: px
Start display at page:

Download "CSR-DAT. Implant system Key to implant codes Table of colour codes ZirTi surface. The Range CSR-DAT implants"

Transcription

1 Catalogue

2

3 CSR-DAT Implant system Key to implant codes Table of colour codes ZirTi surface The Range CSR-DAT implants 6 6 Surgical instruments Surgical Kit Initial and intermediate drills Final drills, related stops and countersink drills Additional instruments Prosthetic components Healing abutments Impression and model phase SIMPLE temporary posts Pre-made posts Preparable posts Castable posts with base in gold alloy and cobalt-chrome P.A.D. (Disparallel Screwed Prostheses) P.A.D. for the D.P.F. tecnique (Direct Prosthetic Framework) Echo custom-made prosthesis T-Connect Locator R-Tx abutments Accessories for overdenture on Locator R-Tx abutments Overdenture on ball attachments Accessories for overdenture on ball attachments Overdenture on bars General indications Composition of the materials Advice for overcasting with base alloys Bibliography on Sweden & Martina implants since

4 IMPLANT SYSTEM Key to implant codes Implants are coded with mnemonic codes that allow easy identification of the piece. Below is a table showing how the mnemonic codes work using VSR-ZT as an example: type of implant surface diameter length VSR ZT VSR: CSR-DAT implant ZT: ZirTi surface 380: 3.80 mm 420: 4.20 mm This is the dimension of the endosseous diameter of the implant, measured at the medial third. 065: 6.50 mm 085: 8.50 mm 100: mm 115: mm 130: mm 150: mm 180: mm Nominal length expressing the endosseous length of the implant. All measurements are in mm, unless otherwise indicated. Table of colour codes A colour code system has been defined in the CSR-DAT implant system to identify the endosseous diameter of the implant. Transfers for taking impressions, laboratory analogues, final drills and the sequence on the surgical tray are also identified with the colour code. implant ø colour code on pack and reference on surgical tray connection platform ø ø 3.00 ø 3.00 main dimensions ø 4.10 ø 4.50 ø 3.80 ø 4.20 final drill fixation screw colour code colour code for implant transfer and analogue M 1.8 M 1.8 4

5 IMPLANT SYSTEM ZirTi surface CSR-DAT implants are available in ZirTi surface, characterized by sand-blasting with zirconium oxide and etching with mineral acids. Sand-blasting with zirconium oxide and etching with mineral acids are processes that give surfaces a characteristic micromorphology capable of increase significantly the bone-to-implant contact area and promote osseointegration ZirTi surface seen at 4.000x and x magnifications using a scanning electron microscope Image of a ZirTi surface portion captured with a radio-frequency optical interferometer: the micromorphology of the surface and the regularity of the peaks obtained with sandblasting and etching treatments can clearly be noted 5

6 THE RANGE CSR-DAT implants CSR-DAT implants are characterized by a cylindrical morphology designed to obtain a great primary stability in any clinical situation, exploiting wherever possible the bicortical engagement. They are available in two diameters sharing the same conical connection of ø 3.00 mm. 6

7 THE RANGE 3.80 mm 4.20 mm 6.50 VSR-ZT VSR-ZT ø 4.10 ø 3.80 ø 2.80 ø ø 4.20 ø VSR-ZT VSR-ZT ø 4.10 ø 3.80 ø 2.80 ø ø 4.20 ø VSR-ZT VSR-ZT ø 4.10 ø 3.80 ø 2.80 ø ø 4.20 ø VSR-ZT VSR-ZT ø 4.10 ø 3.80 ø 2.80 ø ø 4.20 ø VSR-ZT VSR-ZT ø 4.10 ø 4.50 ø 3.80 ø ø 4.20 ø VSR-ZT VSR-ZT ø 4.10 ø 4.50 ø ø ø 2.80 ø VSR-ZT ø 4.10 VSR-ZT ø 4.50 ø ø ø 2.80 ø 3.30 surgical cover screw VSR-VT VSR-VT Every implant is sold with its own surgical cover screw. Surgical cover screws are made of Gr. 4 titanium and are also available individually in sterile packs, and must be tightened to 8-10 Ncm. See technical characteristics of Gr. 4 titanium on page 56. 7

8 SURGICAL INSTRUMENTS Surgical kit The surgical kit of CSR-DAT implant system, designed for the maximum simplicity of use, contains all the instruments necessary for both surgical and prosthetic phases. The instrument categories are screen-printed on the tray to allow the user to identify each instrument during surgery and correctly replace it after cleaning and sterilization procedure. The kit contains dedicated drills for the preparation of both implant diameters, their respective depth stops and Easy Insert Drivers for the correct insertion of the fixtures. The kit consists of a Radel case with a surgical tray designed to hold and display instruments in a guided order of use. The sequences of the instruments to be used are indicated by coloured marks The kit contains a practical torque wrench to control the torque applied for the insertion of implants The compact dimensions of the case make it particularly practical for daily use and transport 8

9 SURGICAL INSTRUMENTS description code Complete surgical kit of the instruments necessary for CSR-DAT implants ZCSR-INT Radel instrument tray for CSR-DAT instruments CSR-TRAY 9

10 SURGICAL INSTRUMENTS Initial and intermediate drills All Sweden & Martina drills are made of surgical stainless steel with high resistance to corrosion and wear. The extreme accuracy of design and production allows use completely free from vibrations and oscillations. Fresa lanceolata: molto tagliente e precisa, facilità l apertura del sito Precision implantare drill: soprattutto very sharp in caso and di precise, osso corticale it facilitates molto duro. the opening of the implant site, especially in cases of very hard cortical bone Pilot and intermediate drill share the same set of stops, designed to allow the drills to be used in total safety during the initial surgical phase Intermediate drill: the progressive geometry of the tip has been designed to guide itself into the hole prepared by the pilot drill Pilot drill: the different heights of the laser markings ensure better visibility in the surgical field and greater ease of recognition of the different depths during use LS LL LL: Total length of the working part, excluding the tip. LS: Length of the tip. This measure must be calculated in addition to the length of the preparation hole

11 SURGICAL INSTRUMENTS precision drill FS-230 precision drill 4.80 pilot drill and intermediate drill CSR-FP-200 pilot drill CSR-FI-280 intermediate drill ø mm ø ø pilot drill and intermediate drill related stops CSR-STOP Stop 6.50 mm for pilot drill and intermediate drill CSR-STOP Stop 8.50 mm for pilot drill and intermediate drill CSR-STOP Stop mm for pilot drill and intermediate drill CSR-STOP Stop mm for pilot drill and intermediate drill CSR-STOP Stop mm for pilot drill and intermediate drill CSR-STOP Stop mm for pilot drill and intermediate drill Please note: CSR-FP-200 and CSR-FI-280 drills always make a hole that is longer than the implant to be inserted. The oversizing (LS) is equal to the height of the tip of the drill used. See drawing on the previous page. 11

12 SURGICAL INSTRUMENTS Final drills, related stops and countersink drill Final drills are made of surgical stainless steel with high resistance to corrosion and wear. The kit contains two final drills for the preparation of sites for the respective implant diameters, which share the same set of stops, and also a countersink drill for the coronal preparation of the site. Final drill ø 3.20 mm for ø 3.80 mm implants Countersink drill Depth stops presents two coloured rings, since they can be used with both the final drills Final drill ø 3.60 mm for ø 4.20 mm implants: the progressive geometry of the tip allows the previous drill to be guided into the preparation hole bored by the previous drill, giving the operator greater control over movement LS LL LL: Total length of the working part, excluding the tip. LS: Length of the tip. This measure must be calculated in addition to the length of the preparation hole

13 SURGICAL INSTRUMENTS implant ø final drill CSR-FF-320 CSR-FF-360 ø ø ø 2.60 ø ø 3.00 ø final drills and related stops CSR-STOP Stop 6.50 mm for final drill CSR-STOP Stop 8.50 mm for final drill CSR-STOP Stop mm for final drill CSR-STOP Stop mm for final drill CSR-STOP Stop mm for final drill CSR-STOP Stop mm for final drill Please note: CSR-FF-320 and CSR-FF-360 drills always make a hole that is longer than the implant to be inserted. The oversizing (LS) is equal to the height of the tip of the drill used. See drawing on the previous page. countersink drill CSR-FC ø 4.45 ø

14 SURGICAL INSTRUMENTS Additional instruments All the additional instruments for CSR-DAT implants, made of surgical stainless steel, have been designed to offer maximum ergonomics and ease of use. All the instruments have a laser-marked code for the easy identification of the piece and are available individually as a spare. Easy Insert driver: engages directly the implant to guarantee a safe grip that does not deform the connection during insertion Driver: solid help for the removal of implants Prosthesic screwdrivers: designed for the retention and fastening of prosthesis fixation screws 14

15 SURGICAL INSTRUMENTS Drivers description code kit Short driver with right angle shank EASYC4-EX230-CA ZCSR-INT Long driver with right angle shank EASYL4-EX230-CA ZCSR-INT Driver with connector for dynamometric key EASY4-EX230-EX ZCSR-INT Drivers description code kit Short driver BC-EX230 ZCSR-INT Long driver BL-EX230 ZCSR-INT Torque wrench with control lever description code kit Torque wrench with control lever allowing torque to be displayed during use. Laser-etched marks at Ncm. TWL ZCSR-INT Important warning In order to respect the tightening torque indicated for each prosthetic component it is recommended the use of the prosthesic screwdrivers with the CRI5-KIT ratchet, working as a dynamometric key with torque control. 15

16 SURGICAL INSTRUMENTS Ratchet description code kit Kit composed of a ratchet and accessories for quick torque adjustment and periodic maintenance (driver and lubricant). The ratchet can be used as a dynamometric key with torque control from 10 to 70 Ncm with adjustment lines at Ncm and as a fixed key CRI5-KIT Not included in the surgical kit, available separately Surgical screwdrivers description code kit Screwdriver for surgical cover screws and fixation screws, digital, extra-short HSMXS-20-DG ZCSR-INT Screwdriver for surgical cover screws and fixation screws, digital, short HSM-20-DG ZCSR-INT Screwdriver for surgical cover screws and fixation screws, digital, long HSML-20-DG ZCSR-INT Prosthesic screwdrivers description code kit Screwdriver for fixation screws, with hexagonal connector for ratchet or hand knob, short HSM-20-EX ZCSR-INT Screwdriver for fixation screws, with hexagonal connector for ratchet or hand knob, long HSML-20-EX ZCSR-INT Screwdriver for fixation screws, with hexagonal connector for ratchet or hand knob, extra-long HSMXL-20-EX ZCSR-INT Driver for fixation screws, with right angle shank HSM-20-CA ZCSR-INT 16

17 SURGICAL INSTRUMENTS Other prosthesic screwdrivers description code kit Screwdriver for ball attachments, with hexagonal connector for ratchet BASCC-EX Not included in the surgical kit, available separately Screwdriver for standard abutments and straight P.A.D. abutments, with hexagonal connector for ratchet AVV2-ABUT ZCSR-INT Digital screwdriver for Locator R-Tx abutments, hexagon 1.25 mm Not included in the surgical kit, available separately Right angle screwdriver for Locator R-Tx abutments, hexagon 1.25 mm Not included in the surgical kit, available separately Instrument for the insertion, fitting and maintaining of the titanium cap for CAP-TIT-1 ball attachments AVV-CAP-TIT-1 Not included in the surgical kit, available separately 17

18 SURGICAL INSTRUMENTS Adaptors and extensions description code kit Extension for drivers, screwdrivers and manual drivers, with hexagonal connector for ratchet BPM-15 ZCSR-INT Extension for surgical drills PROF-CAL3 ZCSR-INT Driver for mounter and mechanical adaptor with right angle shank for instruments with hexagonal connector B-AVV-CA3 ZCSR-INT Screwdriver for right angle instruments with hexagonal connector for ratchet, digital AVV-CA-DG-EX ZCSR-INT P.A.D. transfer screw for manual screwing PAD-VTRAL-140-MAN ZCSR-INT Carrier to transfer angled P.A.D. abutments into the oral cavity, sterilizable and reusable. It must be fixed to abutments with screw PAD-VTRAL-140 PAD-CAR Not included in the surgical kit, available separately Parallelism pins description code kit Parallelism pin PP-2/28 ZCSR-INT ø 2.80 ø 2.00 Parallelism pin with depth lines, large PPTL-2-28 Not included in the surgical kit, available separately ø 2.80 ø Parallelism pin with depth lines, small PPTS-2-28 Not included in the surgical kit, available separately ø 2.80 ø 2.00

19 CSR-L130 rev 02/16 CSR-L120 rev 02/16 CSR-L100 rev 02/16 SURGICAL INSTRUMENTS Depth gauge description code kit Depth gauge PROF3 Not included in the surgical kit, available separately Spare O-ring description code kit Kit with 5 spare O-ring for all accessories with hexagonal connector for dynamometric key and ratchet ORING Not included in the surgical kit, available separately X-ray templates description code kit X-ray template for CSR-DAT implants Real dimensions CSR-L100 ZCSR-INT CSR-DAT RIPRODUZIONE SCALA REALE - REAL DIMENSIONS Impianto cilindrico Fixture ø 3.80 mm Fixture ø 4.20 mm con connessione conica DAT Cylindrical implant with H 6.5 mm H 6.5 mm conical DAT connection VSR-ZT VSR-ZT VSR-M VSR-M ø implant H 8.5 mm H 8.5 mm VSR-ZT VSR-ZT ø max VSR-M VSR-M ø apex H 10 mm H 10 mm VSR-ZT VSR-ZT VSR-M VSR-M H 11.5 mm H 11.5 mm VSR-ZT VSR-ZT VSR-M VSR-M H 13 mm H 13 mm VSR-ZT VSR-ZT VSR-M VSR-M H 15 mm H 15 mm VSR-ZT VSR-ZT VSR-M VSR-M H 18 mm H 18 mm VSR-ZT VSR-ZT VSR-M VSR-M H X-ray template for CSR-DAT implants 20% increased dimensions CSR-L120 ZCSR-INT CSR-DAT RIPRODUZIONE SCALA MAGGIORATA DEL 20% - DIMENSIONS ENLARGED BY 20% Impianto cilindrico Fixture ø 3.80 mm Fixture ø 4.20 mm con connessione conica DAT Cylindrical implant with H 6.5 mm H 6.5 mm conical DAT connection VSR-ZT VSR-ZT VSR-M VSR-M ø implant H 8.5 mm H 8.5 mm VSR-ZT VSR-ZT ø max VSR-M VSR-M ø apex H 10 mm H 10 mm VSR-ZT VSR-ZT VSR-M VSR-M H 11.5 mm H 11.5 mm VSR-ZT VSR-ZT VSR-M VSR-M H 13 mm H 13 mm VSR-ZT VSR-ZT VSR-M VSR-M H 15 mm H 15 mm VSR-ZT VSR-ZT VSR-M VSR-M H 18 mm H 18 mm VSR-ZT VSR-ZT VSR-M VSR-M H X-ray template for CSR-DAT implants 30% increased dimensions CSR-L130 ZCSR-INT CSR-DAT RIPRODUZIONE SCALA MAGGIORATA DEL 30% - DIMENSIONS ENLARGED BY 30% Impianto cilindrico Fixture ø 3.80 mm Fixture ø 4.20 mm con connessione conica DAT Cylindrical implant with H 6.5 mm H 6.5 mm conical DAT connection VSR-ZT VSR-ZT VSR-M VSR-M ø implant H 8.5 mm H 8.5 mm VSR-ZT VSR-ZT ø max VSR-M VSR-M ø apex H 10 mm H 10 mm VSR-ZT VSR-ZT VSR-M VSR-M H 11.5 mm H 11.5 mm VSR-ZT VSR-ZT VSR-M VSR-M H 13 mm H 13 mm VSR-ZT VSR-ZT VSR-M VSR-M H 15 mm H 15 mm VSR-ZT VSR-ZT VSR-M VSR-M H 18 mm H 18 mm VSR-ZT VSR-ZT VSR-M VSR-M H 19

20 PROSTHETIC COMPONENTS Healing abutments The healing abutments are made of Gr. 5 titanium and present an anatomical emergence profile. They must be tightened at a maximum of 10 Ncm, using the HSM screwdrivers series, whose full codes can be found on page 16. Healing abutments are also available with narrow profile, maintaining their diameter at 3.80/4.00 mm, useful in case of reduced interproximal space Healing abutments with regular profile have a diameter that opens out to 4.50 mm and allow excellent tissue reconditioning for the positioning of prosthesis with the same profile diameter Laser marking is located on the upper face of the healing abutment with a reference for the conical connection (with the code V ), and a three numbers code (in this example 453): the first two numbers refer to the coronal dimensions (in this example 45=4.50 mm), and the final number refer to the transgingival height (3= 3.00 mm transgingival height) Transgingival height: height measured from the implant connection platform to the head of the abutment Transgingival height 20

21 PROSTHETIC COMPONENTS prosthesis profile narrow regular emergence profile ø Healing abutment Anatomical emergence profile Transgingival H mm VSR-TMG-1.4-S - ø 3.80 Healing abutment Anatomical emergence profile Transgingival H mm VSR-TMG-2-S VSR-TMG-2 ø 4.00 ø 4.50 Healing abutment Anatomical emergence profile Transgingival H mm VSR-TMG-3-S VSR-TMG-3 ø 4.00 ø 4.50 Healing abutment Anatomical emergence profile Transgingival H mm VSR-TMG-4-S VSR-TMG-4 ø 4.00 ø 4.50 Healing abutment Anatomical emergence profile Transgingival H mm VSR-TMG-5-S VSR-TMG-5 ø 4.00 ø 4.50 Recommended tightening torque for healing abutments: 8-10 Ncm. See technical characteristics of Gr. 5 titanium on page

22 PROSTHETIC COMPONENTS Impression and model phase Components for impressions and models are manufactured with the same machines used to produce implants, ensuring a real guarantee of precision from the point of view of tolerance and fidelity in the reproduction of the clinical situation. Transfers Pick-up and closed-tray transfers are made of Gr. 5 titanium anodized according to the colour code of the reference implant diameter, facilitating the identification of the different fixtures that may be used. A PEEK cap is available for use with closed-tray transfers, allowing more precise impressions to be taken on them. Pick-up transfers: the design of the upper portion guarantees an excellent retention in the impression material Closed-tray transfers: for closed-tray impressions, these are used with a PEEK cap that guarantees a precise and stable positioning in the impression material Pick-up transfers with narrow profile: to be distinguished from the transfers with regular profile, they have a white laser marking, and allow the taking of impressions in case of reduced interproximal space 22

23 PROSTHETIC COMPONENTS Pick-up transfers prosthesis profile narrow regular implant ø Pick-up transfer Straight emergence profile Fixation screw included VSR-TRA-380-S VSR-TRA-380 VSR-TRA ø 4.00 ø 4.50 ø 4.50 Fixation screw Supplied with transfers and also available separately as a spare Single pack VSR-VTRA Use VSR-VTRA Use VSR-VTRA M 1.8 Fixation screw for pick-up transfer For manual screwing VSR-VTRA-180-MAN Use VSR-VTRA-180-MAN Use VSR-VTRA-180-MAN Not included with transfers, available optionally* in single pack M 1.8 Optional fixation screw Not included with transfers, available optionally* in single pack VSR-VTRA Use VSR-VTRA Use VSR-VTRA M 1.8 Optional fixation screw Not included with transfers, available optionally* in single pack VSR-VTRA Use VSR-VTRA Use VSR-VTRA M 1.8 Recommended tightening torque for the transfer screws: 8-10 Ncm. *Pick-up transfer package includes VSR-VTRA screw. The other optional screws must be ordered separately. See technical characteristics of Gr. 5 titanium on page

24 PROSTHETIC COMPONENTS Closed-tray transfers implant ø Closed-tray transfer Straight emergence profile Fixation screw included VSR-TRAS-380 VSR-TRAS-420 ø ø PEEK cap for taking impression Not included with transfer, available separately as a spare U-CAPM-380 ø Use U-CAPM-380 Fixation screw for transfers VSR-VTRA Use VSR-VTRA Supplied with transfer and also available separately as a spare Single pack M Optional fixation screw Not included with transfer, available optionally Single pack VSR-VTRA Use VSR-VTRA M 1.8 Recommended tightening torque for the transfer screws: 8-10 Ncm. 24 See technical characteristics of Gr. 5 titanium on page 57.

25 PROSTHETIC COMPONENTS Analogues Analogues for CSR-DAT implants are made of Gr. 5 titanium, coloured according to the colour code of the related implant diameter. Even though the implants share the same connection (conical with ø 3.00 mm) individual analogues have been produced for both implants to allow the laboratory to precisely replicate the platform and the emergence anatomy of the respective diameter. implant ø CSR-DAT implant analogue VSR-ANA-380 VSR-ANA-420 ø ø See technical characteristics of Gr. 5 titanium on page

26 PROSTHETIC COMPONENTS SIMPLE temporary posts Temporary posts can be used in a conventional way after the bone healing period, or immediately after surgical insertion of the implants, if conditions for immediate loading are present. They can also be used as an alternative to the traditional healing abutments for soft tissues reconditioning, depending on the prosthetic protocols adopted. PEEK is an extremely strong biocompatible material, even though it can be easily milled at the chairside. The titanium base guarantees maximum connection precision. PEEK posts are ideal to support single cemented crowns The repositioning hexagon of the temporary titanium posts guarantees the non-rotational aspect, ideal to create temporary single and screwretained prostheses The centring cone of the temporary posts without the repositioning hexagon facilitates the insertion into the conical connection 26

27 PROSTHETIC COMPONENTS implant ø SIMPLE temporary posts in PEEK with base in Gr. 5 titanium Engaging With hexagon Fixation screw included VSR-MPSC ø 5.70 ø SIMPLE temporary posts in Gr. 5 titanium Engaging With hexagon Fixation screw included VSR-MP 9.20 ø SIMPLE temporary posts in Gr. 5 titanium Non engaging Fixation screw included VSR-MP-ROT 9.20 ø Single pack Pack of 10 pieces VSR-VM-180 VSR-VM Fixation screw supplied with temporary posts and also available separately as a spare M 1.8 During laboratory phases tightening torque must not exceed 8-10 Ncm. Recommended torque for fixation screws: Ncm. Important warning It is recommended to respect the tightening torque, otherwise the conical coupling of the connection could make the remotion of the screw and the post difficult. Important warning It is recommended always to use test screws for the laboratory phases and to keep the new screw supplied for the final fastening in the oral cavity. See technical characteristics of Gr. 5 titanium and PEEK on pages 57 and

28 PROSTHETIC COMPONENTS Pre-made posts Produced in Gr. 5 titanium, these posts are subjected to a controlled passivation process that changes their surface colour to a characteristic golden pale yellow colour. This colour is obtained through an oxidation process and, therefore, there is no type of coating, ensuring the use of a highly biocompatible surface. Pre-made posts for direct screwing are available, ideal for One-Abutment-One-Time protocols. They are also particularly useful for the stabilization of intraoral welding titanium bars for rehabilitations with immediate loading, because this technology guarantees the absolute immobility of both the prosthesis and the implant. The analogue of the post for direct screwing is anodized according to the colour code of the reference implant diameter. In One-Abutment-One-Time protocol, when the impression is taken directly on the post, the position and emergence of the implant and post can be transferred to the laboratory Angled posts offer an angle of 15 and are available with a regular and a narrow profile One-piece abutments have a recess, inside which a screwdriver of HSM system must be inserted for the tightening A PEEK cap for taking impression directly on posts is available 28

29 PROSTHETIC COMPONENTS implant ø Solid one-piece abutments Non engaging VSR-MDAD Use VSR-MDAD 8.00 ø 3.90 Analogue for solid one-piece abutments VSR-ANAMD VSR-ANAMD ø 3.80 ø 4.20 PEEK cap for taking impression directly on post U-CAPM-380 Use U-CAPM-380 ø Recommended definitive tightening torque for solid one-piece abutments: Ncm. During laboratory phases and any chairside examinations, tightening torque must not exceed 8 10 Ncm. Important warning It is recommended to respect the tightening torque, otherwise the conical coupling of the connection could make the remotion of the screw and the post difficult. Important warning It is recommended always to use test screws for the laboratory phases and to keep the new screw supplied for the final fastening in the oral cavity. See technical characteristics of Gr. 5 titanium and PEEK on pages 57 and

30 PROSTHETIC COMPONENTS prosthesis profile narrow regular emergence profile ø Straight pre-made posts Engaging Transgingival H mm Fixation screw included VSR-MDPF ø Straight pre-made posts Engaging Transgingival H mm Fixation screw included - VSR-MD ø Straight pre-made posts Engaging Transgingival H mm Fixation screw included - VSR-MD ø Straight pre-made posts Engaging Transgingival H mm Fixation screw included - VSR-MD-4 ø PEEK cap for taking impression directly on post U-CAPM-380 ø Use U-CAPM-380 Single pack Pack of 10 pieces VSR-VM-180 VSR-VM Use VSR-VM-180 Fixation screw supplied with the posts and also available separately as a spare M 1.8 Recommended torque for definitive fastening of fixation screws: Ncm. During laboratory phases and any chairside examinations, tightening torque must not exceed 8 10 Ncm. Important warning It is recommended to respect the tightening torque, otherwise the conical coupling of the connection could make the remotion of the screw and the post difficult. 30 See technical characteristics of Gr. 5 titanium and PEEK on pages 57 and 58.

31 PROSTHETIC COMPONENTS prosthesis profile narrow regular emergence profile ø Angled pre-made posts at 15 Engaging Fixation screw included VSR-MAPF VSR-MA ø ø PEEK cap for taking impression directly on post U-CAPM-380 Use U-CAPM-380 ø Single pack Pack of 10 pieces Fixation screw supplied with the posts and also available separately as a spare VSR-VM-180 VSR-VM M 1.8 Use VSR-VM-180 Recommended torque for definitive fastening of fixation screws: Ncm. During laboratory phases and any chairside examinations, tightening torque must not exceed 8 10 Ncm. Important warning It is recommended to respect the tightening torque, otherwise the conical coupling of the connection could make the remotion of the screw and the post difficult. Important warning It is recommended always to use test screws for the laboratory phases and to keep the new screw supplied for the final fastening in the oral cavity. See technical characteristics of Gr. 5 titanium and PEEK on pages 57 and

32 PROSTHETIC COMPONENTS Preparable posts They are made of Gr. 5 titanium and are able to respond to complex anatomical requirements in terms of both narrow prosthetic spaces and disparallel implants, since they can be milled. The connections of milled posts are indexed, ideal in case of rehabilitations with cemented single crowns or multiple prostheses. Pre-cut posts: allow very pronounced angles to be reached, up to 25, limiting the time needed to reduce them by milling Post with a narrow profile can be adapted to the anatomy obtained with narrow temporary posts, so that highly custom-made prostheses can be produced 32

33 PROSTHETIC COMPONENTS Prosthesis profile narrow regular emergence profile ø Preparable posts Engaging Fixation screw included VSR-MF-S VSR-MF ø ø Pre-cut posts Engaging Fixation screw included - VSR-MFP ø Single pack Pack of 10 pieces Fixation screw supplied with the posts and also available separately as a spare VSR-VM-180 VSR-VM M 1.8 Use VSR-VM-180 Recommended torque for definitive fastening of fixation screws: Ncm. During laboratory phases and any chairside examinations, tightening torque must not exceed 8 10 Ncm. Important warning It is recommended to respect the tightening torque, otherwise the conical coupling of the connection could make the remotion of the screw and the post difficult. Important warning It is recommended always to use test screws for the laboratory phases and to keep the new screw supplied for the final fastening in the oral cavity. See technical characteristics of Gr. 5 titanium on page

34 PROSTHETIC COMPONENTS Castable posts with base in gold alloy and cobalt-chrome Castable posts with a metal base combine the simplicity of castable solutions with a base in gold alloy or cobalt-chrome, highly biocompatible materials. The melting point of the above-mentioned alloys permits to preserve the base against dimensional alterations during the overcasting of the castable part, thereby maintaining the precision of the post-implant connection. The engaging version, with hexagon, is ideal for single rehabilitations The non engaging version has a guide cylinder for the insertion into the connection, in order to make this easier in case of multiple rehabilitations 34

35 PROSTHETIC COMPONENTS prosthesis profile narrow regular emergence profile ø Castable posts with pre-made base in gold alloy 1 For overcasting Engaging With hexagon Fixation screw included VSR-UC-S ø VSR-UC ø Castable posts with pre-made base in gold alloy 1 For overcasting Non engaging Fixation screw included - VSR-UC-ROT ø Castable posts with pre-made base in cobalt-chrome For overcasting Engaging With hexagon Fixation screw included VSR-UCRCO-S ø VSR-UCRCO ø Castable posts with pre-made base in cobalt-chrome For overcasting Non engaging Rotating Fixation screw included - VSR-UCRCO-ROT ø Spare castable sleeves for castable posts with pre-made base in gold alloy and cobalt-chrome Single pack Fixation screw not included A-CCUCR-330 A-CCUCR Single pack Pack of 10 pieces Fixation screw supplied with the posts and also available separately as a spare VSR-VM-180 VSR-VM M 1.8 Use VSR-VM-180 Recommended torque for fixation screws: Ncm. During laboratory phases and any chairside examinations, tightening torque must not exceed 8 10 Ncm. Important warning It is recommended to respect the tightening torque, otherwise the conical coupling of the connection could make the remotion of the screw and the post difficult. Important warning It is recommended always to use test screws for the laboratory phases and to keep the new screw supplied for the final fastening in the oral cavity. See technical characteristics of gold alloy 1 and cobalt-chrome on pages 61 and 62 respectively. 35

36 PROSTHETIC COMPONENTS P.A.D. (Disparallel Screwed Prosthesis) P.A.D. system has been developed to facilitate the realization of multiple screw-retained prostheses even in presence of divergent implants and disparallel prosthetic emergence axes. In particular, P.A.D. angled abutments are simple and predictable solutions for implants positioned with an extreme inclination in distal saddles. P.A.D. system is characterized by its great versatility, including a wide range of straight abutments (available in various transgingival heights, from 1.00 mm to 4.00 mm), angled abutments (available with inclinations of 30 and 17 ) and a complete line of components necessary for the production of over-structures (transfers, analogues, sleeves, etc). P.A.D. posts: they all have the same upper cone, angled at 15, which facilitates the manoeuvres of insertion and removal of multiple screw-retained prostheses Upper cone allows further repositioning of the prosthetic structure by 15 per side, which in the case of angled P.A.D. abutments are added to the angles of 17 or 30. This characteristic allows easy management of disparallelism of up to 45 per side. 36 Important warning It is recommended always to use test screws for the laboratory phases and to keep the new screw supplied for the final fastening in the oral cavity.

37 PROSTHETIC COMPONENTS implant ø Straight P.A.D. abutments Transgingival H mm VSR-PAD-AD-10 ø Straight P.A.D. abutments Transgingival H mm VSR-PAD-AD-20 ø Straight P.A.D. abutments Transgingival H mm VSR-PAD-AD-30 ø Straight P.A.D. abutments Transgingival H mm VSR-PAD-AD-40 ø P.A.D. abutments Angled at 17 Transgingival H mm VSR-PAD-AA-173 ø P.A.D. abutments Angled at 30 Transgingival H mm VSR-PAD-AA-303 ø Single pack Pack of 10 pieces VSR-VM-180 VSR-VM Fixation screw supplied and also available separately as a spare M 1.8 Driver for standard abutments and P.A.D. abutments, with hexagonal connector for ratchet Not included in the surgical kit, available separately AVV2-ABUT P.A.D. transfer screw for manual screwing, usable as a carrier to transport angled P.A.D. abutments into the oral cavity, sterilizable and reusable PAD-VTRAL-140-MAN M 1.4 Carrier to transfer angled P.A.D. abutments into the oral cavity, sterilizable and reusable. It must be fixed to abutments with screw PAD-VTRAL-140 Not included in the surgical kit, available separately PAD-CAR Recommended tightening torque for directly screwed posts: Ncm. Recommended torque for fixation screws: Ncm. During laboratory phases and any chairside examinations, tightening torque must not exceed 8 10 Ncm. Important warning It is recommended to respect the tightening torque, otherwise the conical coupling of the connection could make the remotion of the screw and the post difficult. See technical characteristics of Gr. 5 titanium on page

38 PROSTHETIC COMPONENTS P.A.D. components description code Protection cap for P.A.D. abutments in Gr. 5 titanium. Fixation screw included (code PAD-VP-140) PAD-CG Protection cap for P.A.D. abutments in PEEK. Fixation screw included (code PAD-VP-140) PAD-CGP Non engaging rotating caps in POM for direct impression taking on P.A.D. abutments PAD-CAP Engaging caps in POM for direct impression taking on P.A.D. abutments, with hexagon PAD-CAP-EX Pick-up transfer in Gr. 5 titanium for P.A.D. abutments, rotating Long transfer screw included (code PAD-VTRAL-140) PAD-TRA Pick-up transfer in Gr. 5 titanium for P.A.D. abutments, with hexagon, non-rotating Long transfer screw included (code PAD-VTRAL-140) PAD-TRA-EX Spare long screw for P.A.D. transfers supplied with transfers and also available separately as a spare PAD-VTRAL-140 Spare screw for P.A.D. transfers supplied with transfers and also available separately as a spare PAD-VTRA-140 Analogue for P.A.D. abutments in Gr. 5 titanium PAD-ANA Castable sleeves in PMMA for P.A.D. abutments, rotating Fixation screw included PAD-CC 38 See technical characteristics of Gr. 5 titanium, PMMA, POM and gold alloy 1 from page 57.

39 PROSTHETIC COMPONENTS description code Castable sleeves in PMMA for P.A.D. abutments, with hexagon, non-rotating Fixation screw included PAD-CC-EX Castable posts in PMMA with a pre-made base in gold alloy 1, rotating, non engaging, for overcasting on P.A.D. abutments Fixation screw included Castable posts in PMMA with a premade base in cobalt-chrome, rotating, non engaging, for overcasting on P.A.D. abutments Fixation screw included Spare screw for P.A.D. abutment prosthetic components Supplied with all the components for making the over-structure and also available as a spare Also available in packs of 10 pieces (code PAD-VP ) PAD-UC PAD-UCRCO PAD-VP-140 P.A.D. components for the reline and the cemented technique description code Sleeves in PEEK for P.A.D. abutments, rotating for the relining of existing prosthesis Fixation screw included (code PAD-VP-140) PAD-CP Sleeves in PEEK for P.A.D. abutments, with hexagon, non-rotating for the relining of existing prosthesis Fixation screw included (code PAD-VP-140) PAD-CP-EX Sleeves in Gr. 5 titanium for P.A.D. abutments, rotating for the relining of existing prosthesis Fixation screw included (code PAD-VP-140) PAD-CT Sleeves in Gr. 5 titanium for P.A.D. abutments, with hexagon, non-rotating for the relining of existing prosthesis Fixation screw included (code PAD-VP-140) PAD-CT-EX Castable posts in PMMA for cementing techniques on sleeves in Gr. 5 titanium PAD-CCEM Spare screw for P.A.D. abutments prosthetic components supplied with all the components for making the over-structure and also available as a spare Also available in packs of 10 pieces (code PAD-VP ) PAD-VP-140 Recommended tightening torque for fixing protection caps: 8-10 Ncm. Recommended torque for fixing prosthetic screws: Ncm. Important warning It is recommended always to use test screws for the laboratory phases and to keep the new screw supplied for the final fastening in the oral cavity. See technical characteristics of Gr. 5 titanium, PMMA, POM and gold alloy 1 from page

40 PROSTHETIC COMPONENTS P.A.D. for the D.P.F. technique (Direct Prosthetic Framework) P.A.D. abutments have demonstrated to be valid supports for the application of various simplified prosthetic protocols, including the creation of temporary structures for full-arch implant rehabilitations with immediate loading, using a very safe and simple procedure. D.P.F. components have been specifically developed to create a castable absolutely passive resin structure directly in the oral cavity, not restricted by connection geometries, without imprecisions due to the taking of impression and the development of the model. The metal truss intraoral cementation obtained subsequently by casting makes it possible to reduce insertion times for a reinforced temporary prosthesis to 8 hours after the completion of surgery, at the same time conserving all the important requirements of resistance and passivity during the initial phase of implant loading. The temporary structure thus created can also be used as a position template for the production of the definitive prosthesis. STEP 3 The assembled structure is casted in the laboratory, obtaining the metal structure for the final truss STEP 1 The castable bar is fixed to the caps with a photo-polymerisable resin STEP 2 After photo-polymerisation of the truss, the structure is removed from the oral cavity 40

41 PROSTHETIC COMPONENTS description code Set of all the components for the D.P.F. technique on a single P.A.D. abutment The set includes the titanium sleeve (PAD-CT-LV), the castable centring device (PAD-CC-LV), the anti-escape plug (PAD-TR-LV), the protective O-ring (PAD-ORING-LV) and the fixation screw (PAD-VP-140) PAD-LV Spare titanium sleeve for the D.P.F. technique The pack does not include the fixation screw PAD-CT-LV ø 5.00 Spare castable centring device for the D.P.F. technique PAD-CC-LV ø Spare anti-escape plug for the D.P.F. technique PAD-TR-LV ø Spare O-ring for the D.P.F. technique PAD-ORING-LV Single pack Pack of 10 pieces PAD-VP-140 PAD-VP Spare screw for P.A.D. abutment prosthetic components M 1.4 Castable bar, L cm, ø 2.20 mm BARC Recommended tightening torque: Ncm. 41

42 PROSTHETIC COMPONENTS Echo custom-made prosthesis Maximum aesthetic results and design flexibility, in the case of custom-made prosthesis, can be reached with custom-made Echo posts and Echo Direct Bridges, designed using CAD-CAM technique and produced by Sweden & Martina Echo milling centre. Custom-made titanium posts represent the evolution of millable posts, as they permit excellent adaptation of the prosthesis to the patient s gingival anatomy, difficult to achieve with conventional laboratory techniques. Posts in zirconium oxide are also available, currently representing the most advanced custom-made solution, as they offer many advantages in terms of the translucence of restorations, extreme personalization of the manufacture, biocompatibility and the absence of corrosion in the oral cavity, maximum connection precision, excellent resistance to occlusal loads, lower invasiveness due to perfect adaptation to tissues and shorter chairside times. The aluminium Scan-transfer is available for scanning (see following pages). For further information on the Echo system, contact Sweden & Martina CAD-CAM product specialists. Custom-made posts: Biomedical Gr. 5 titanium Zirconia Milled cobalt-chrome Laser-melted cobalt-chrome PEEK Biomedical resin for temporary structures Fibreglass Lithium disilicate Milled bars screwed onto implants: Milled biotitanium Milled cobalt-chrome 42

43 PROSTHETIC COMPONENTS DIRECT/TORONTO Bridge and screwed bridges with connector for T-Connect supports cementing: Biomedical Gr. 5 titanium Zirconia Milled cobalt-chrome Sintered cobalt-chrome PMMA PEEK Biomedical resin for temporary structures Fibreglass Lithium disilicate Bridge structure screwed to DIRECT/TORONTO Bridge: Biomedical Gr. 5 titanium Zirconia Milled cobalt-chrome Biomedical resin for temporary structures 43

44 PROSTHETIC COMPONENTS implant ø Laboratory scan transfer in Ergal Fixation screw included VSR-CAMETRA Scanbody in PEEK specific for intraoral use Fixation screw included VSR-INT-CAMTRA 7.00 Single pack Pack of 10 pieces VSR-VM-180 VSR-VM Spare screw for scan transfer and Echo scanbody for implants M 1.8 Recommended tightening torque: 8 10 Ncm. Important warning It is recommended to respect the tightening torque, otherwise the conical coupling of the connection could make the remotion of the screw and the post difficult. 44

45 PROSTHETIC COMPONENTS implant ø ECHO scan transfer in aluminium to transfer the positioning of P.A.D. connections Engaging Fixation screw included PAD-CAMETRA ø 5.00 Single pack PAD-VCAM-140 Spare screw for tightening prosthetic over-structures in zirconium oxide on P.A.D. abutments in Gr. 5 titanium complete with lock ring washer M 1.4 Single pack Pack of 10 pieces PAD-VP-140 PAD-VP Spare screw for tightening prosthetic over-structures ECHO in titanium and cobalt-chrome on P.A.D. abutments in Gr. 5 titanium M 1.4 Pack of 10 pieces CAMPRON Spare lock ring washers for fixation screw heads, for custom-made posts in zirconium oxide, ECHO structures in classic PEEK and over-structures in zirconium oxide Recommended tightening torque: Ncm. Important warning In the case of prostheses on more than one post, it is recommended to fix transfers together with resin to guarantee the stability and solidity of the impression. 45

46 PROSTHETIC COMPONENTS T-Connect T-Connect supports are made of Gr. 5 titanium and can be used to create custom-made posts for single or multiple prostheses in titanium, zirconia, cobalt-chrome, PEEK and biomedical resin, using open CAD-CAM systems, including Echo by Sweden & Martina, without sacrificing the micrometric precision in coupling between platforms that can be obtained with conventional components. Echo users can also choose to use T-Connect supports: posts in zirconium produced in this way have a small titanium base that prevents the contact between the zirconium body and the implant platform. If posts are made through Echo software, see page 44 for the scan transfer codes to be used. For further information on compatible systems contact Sweden & Martina CAD-CAM product specialists at Special sleeves to be fitted onto the conical body of T-Connect supports facilitate modelling the wax-up while respecting volumes; the total height of mm helps to preserve the screw hole from accidental obstructions The cementing cone is available in two heights: 4.00 mm and 6.00 mm T-Connect supports are available both with a repositioning index for single crowns and in a rotating version for multiple rehabilitations 46

47 PROSTHETIC COMPONENTS implant ø T-Connect supports for single prosthesis Cementing cone H mm Fixation screw included VSR-BASTZR-S-4 ø T-Connect supports for multiple prosthesis Cementing cone H mm Fixation screw included VSR-BASTZR-M-4 ø T-Connect supports for single prosthesis Cementing cone H mm Fixation screw included VSR-BASTZR-S-6 ø T-Connect supports for multiple prosthesis Cementing cone H mm Fixation screw included VSR-BASTZR-M ø Single pack Pack of 10 pieces VSR-VM-180 VSR-VM Fixation screw supplied with T-Connects and also available separately as a spare M 1.8 Sleeve for wax-up modelling on T-Connect supports with cone H mm A-CCBAS Sleeve for wax-up modelling on T-Connect supports with cone H mm A-CCBAS Recommended torque for fixation screws: Ncm. Important warning It is recommended to respect the tightening torque, otherwise the conical coupling of the connection could make the remotion of the screw and the post difficult. Important warning It is recommended always to use test screws for the laboratory phases and to keep the new screw supplied for the final fastening in the oral cavity. See technical characteristics of Gr. 5 titanium and PMMA on pages 57 and 59 respectively. 47

48 PROSTHETIC COMPONENTS Locator R-Tx abutment Locator R-Tx* abutments are a simple, safe and versatile patented prosthetic solution for anchoring overdentures to implants. The latest generation of the system developed by Zest Anchors has a double retention for engagement and a narrow coronal profile for an easy prosthesis insertion. The Locator R-Tx system permits to correct the insertion axis by up to a total of 60 (30 per implant). The abutments are made of Gr. 5 titanium and are available in different transgingival heights. They must be tightened to Ncm using the optional screwdrivers available, which codes can be found on page 51. Locators R-Tx are included in all-in-one package, including inserts with various levels of retention and a metal cap. See pages 50 and 51 for a list of the accessories available. Locator R-Tx system includes a cap with augmented geometry to resist movements, coloured in pink for enhanced aesthetic results The new DuraTec treatment, a nitriding process that alternates layers of titanium and carbon, gives Locator R-Tx abutments a highly aesthetic pink colouration, robust and resistant to wear Greater possibility to correct the insertion axis and five inserts with different retention levels 48

49 PROSTHETIC COMPONENTS implant ø Locator R-Tx abutments Transgingival H mm All-in-one package ø Locator R-Tx abutments Transgingival H mm All-in-one package ø Locator R-Tx abutments Transgingival H mm All-in-one package ø Locator R-Tx abutments Transgingival H mm All-in-one package ø Locator R-Tx abutments Transgingival H mm All-in-one package ø Locator R-Tx abutments Transgingival H mm All-in-one package ø Recommended torque for definitive tightening: Ncm. During laboratory phases and any chairside examinations, tightening torque must not exceed 8 10 Ncm. Important warning It is recommended to respect the tightening torque, otherwise the conical coupling of the connection could make the remotion of the screw and the post difficult. Important warning It is recommended always to use test screws for the laboratory phases and to keep the new screw supplied for the final fastening in the oral cavity. *Locator R-Tx abutments and their respective accessories on the following pages are medical devices manufactured and patented by Zest Anchors, 2875 Loker Avenue East, Carlsbad, CA92010, USA. Locator R-Tx is a registered trademark of Zest Anchors, Inc. The European Authorized Representative for the purposes of the Medical Devices Directive 93/42/EEC is Ventura Implant and Attachment Systems, 69 The Avenue, Ealing, London W13 8JR, England. 49

50 PROSTHETIC COMPONENTS Accessories for overdenture on Locator R-Tx abutments description code Kit containing 2 AC caps, 2 spacer rings, 2 black retainers for taking impression and 2 inserts for each of the four retention levels (without retention, low retention, medium retention and high retention) Pack of 4 grey inserts, without retention Pack of 4 blue inserts, low retention Pack of 4 pink inserts, medium retention Pack of 4 white inserts, high retention Pack of 4 light blue inserts, extra retention Pack of 4 retainers in black plastic for taking impression Pack of 20 spacer rings for the prosthesis relining phase Pack of 4 aluminium analogues for Locator R-Tx abutment ø 3.35 mm

51 PROSTHETIC COMPONENTS description codice Pack of 4 aluminium analogues for Locator R-Tx abutments ø 4.00 mm Pack of 4 aluminium analogues for Locator R-Tx abutments ø 5.00 mm Pack of 4 transfers for Locator R-Tx abutments with low retention, single size for all platforms Pack of 4 spacer rings for the prosthesis relining phase Locator Core Tool. Steel instrument for the insertion of retainers in caps and in the retaining sleeve for drivers to transfer the Locator R-Tx abutments into the oral cavity Digital screwdriver for Locator R-Tx abutments, hexagon 1.25 mm Screwdriver for right angle for Locator R-Tx abutments, hexagon 1.25 mm

52 PROSTHETIC COMPONENTS Overdenture on ball attachments The anchoring system with ball attachments, also known as ball joints, is composed of a Gr. 5 titanium post with spherical top with a diameter of 2.20 mm and of a selection of many anchoring matrices that can be directly incorporated into the removable prosthesis. See the following pages for a list of the matrices available and the respective accessories. 52

53 PROSTHETIC COMPONENTS implant ø Ball attachments Transgingival H mm VSR-AS-1 ø 2.20 ø Ball attachments Transgingival H mm VSR-AS-2 ø 2.20 ø Ball attachments Transgingival H mm VSR-AS-3 ø 2.20 ø Ball attachments Transgingival H mm VSR-AS-4 ø 2.20 ø Analogue of the ball attachment ANAS ø 2.20 ø Steel screwdriver for ball attachments, with connector for ratchet or manual knob BASCC-EX Not included in the surgical kit, available separately Recommended torque for definitive tightening: Ncm. During laboratory phases and any chairside examinations, tightening torque must not exceed 8 10 Ncm. Important warning It is recommended to respect the tightening torque, otherwise the conical coupling of the connection could make the removal of the post difficult. See technical characteristics of Gr. 5 titanium on page

54 PROSTHETIC COMPONENTS Accessories for overdenture on ball attachments Polyamide caps for ball attachments description code Polyamide cap for ball attachments ø 2.20 mm CAP-TFL-1 Steel container for polyamide cap with outer ø 4.8 mm The total height is 3.20 mm CONT-CAP-TFL-1 Titanium caps for ball attachments description code Gr. 5 titanium cap complete with cap in two parts, titanium retention spring and plastic mounting ring for ball attachments ø 2.20 mm. The total height is 3.20 mm CAP-TIT-1 Spare plastic ring for titanium cap H 2.20 mm AN-CAP-TIT-1 Spare retention spring for titanium cap, average hardness, steel, ø 3.20 mm MOL1-CAP-TIT-1 Spare retention spring for titanium cap, soft, for progressive adaptation of prostheses, steel, ø 3.20 mm MOL2-CAP-TIT-1 Driver for mounting and maintenance of the titanium cap CAP-TIT-1 AVV-CAP-TIT-1 Gold alloy caps for ball attachments description code Gold alloy 2 caps for ball attachments ø 2.20 mm, complete with 3 plastic positioning rings and a tin laboratory spacer. The total height is 3.10 mm, and the external diameter is 3.50 mm CAP-1 54

55 PROSTHETIC COMPONENTS O-ring retention devices for ball attachments* description code Ring-shaped metal container for rubber O-rings. For ball attachments ø 2.20 mm. The total height is 1.50 mm, and the external diameter is 4.50 mm Pack of 6 pieces * Red ring in silicon for laboratory use, outside ø 4.50 mm, H mm Pack of 12 pieces * White ring in natural rubber, soft, outside ø 4.50 mm, H mm Pack of 12 pieces * Black ring in natural rubber, hard, outside ø 4.50 mm, H mm Pack of 12 pieces * *Retention O-rings for ball attachments are manufactured by Implant Direct Sybron International, Malibu Hills Road, Calabasas Hills, U.S.A. The European Authorized Representative for the purposes of the Medical Devices Directive 93/42/EEC is Kerr Italia Srl, 332 Via Passanti, Scafati (SA), Italy. Overdenture on bars description code Castable bar, L cm, H. 3.00, thickness 2.20 mm Ovoid-shaped profile with spacer BAR-CAV-TIT Divisible bar attachment in titanium for oval bars, H mm, thickness 2.20 mm CAV-TIT Castable bar, L cm, ø 2.20 mm BARC Bar attachment in gold alloy 3, for round bars ø 2.20 mm CAV-375 See technical characteristics of Gr. 5 titanium on page

Prama. Implant system 4 ZirTi Surface 4 Key to implant codes 4 Table of colour codes 5. The range 6 Prama 6 Prama RF 7

Prama. Implant system 4 ZirTi Surface 4 Key to implant codes 4 Table of colour codes 5. The range 6 Prama 6 Prama RF 7 Catalogue Prama Implant system 4 ZirTi Surface 4 Key to implant codes 4 Table of colour codes 5 The range 6 Prama 6 Prama RF 7 Surgical instruments 10 Surgical kit 10 Initial and intermediate drills 12

More information

Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Sweden & Martina or distributor sales office

Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Sweden & Martina or distributor sales office Catalogue Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Sweden & Martina or distributor sales office for current products availability. Premium

More information

Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Sweden & Martina or distributor sales office

Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Sweden & Martina or distributor sales office Product catalogue Some products may not be regulatory cleared/released for sale in all markets. Please contact the local Sweden & Martina or distributor sales office for current products availability.

More information

Guide to the sequence of use of prosthetic components

Guide to the sequence of use of prosthetic components Prosthetic Manual PRAMA Guide to the sequence of use of prosthetic components 4 Platform connection Guide chart to the single prosthetic connection Connection details Contracone seal Prosthetic screws

More information

I M P L A N T O L O G Y

I M P L A N T O L O G Y IMPLANTOLOGY Premium Straight The cylindrical implant with 16 years of clinical success and over 60 publications. All Premium Straight implants have a smooth collar 0.80 mm high, a cylindrical shape and

More information

A complete surgical kit for Premium and Shelta systems

A complete surgical kit for Premium and Shelta systems SURGICAL KIT A complete surgical kit for Premium and Shelta systems The combined Premium Shelta surgical kit contains the instruments for the surgical and prosthetic phases of the fixtures of both implant

More information

A complete surgical kit for Premium and Shelta systems

A complete surgical kit for Premium and Shelta systems SURGICAL KIT A complete surgical kit for Premium and Shelta systems The combined Premium Shelta surgical kit contains the instruments for the surgical and prosthetic phases of the fixtures of both implant

More information

OVERDENTURE PROSTHETIC MANUAL. Shelta

OVERDENTURE PROSTHETIC MANUAL. Shelta OVERDENTURE PROSTHETIC MANUAL Shelta PROSTHETIC MANUAL TABLE OF CONTENTS Connection platform 6 Anchoring with Locator abutments 34 Prosthetic instruments 12 Anchoring with ball attachments 50 Techniques

More information

CSR-DAT. The range 12 CSR-DAT implants 12

CSR-DAT. The range 12 CSR-DAT implants 12 Surgical Manual CSR-DAT The Implants 4 Clinical indications for the application of implant-prosthetic therapies 4 Side and secondary effects 5 General indications 6 Method of use 7 CSR-DAT implants 8

More information

Shelta. Implant system 4 ZirTi surface 4 Key to the implant codes 5. The range 6 Shelta implants 6 Shelta SL implants 8

Shelta. Implant system 4 ZirTi surface 4 Key to the implant codes 5. The range 6 Shelta implants 6 Shelta SL implants 8 Catalogue Shelta Implant system 4 ZirTi surface 4 Key to the implant codes 5 The range 6 Shelta implants 6 Shelta SL implants 8 Surgical intruments 10 Surgical Kit 10 A complete surgical kit for Premium

More information

NARROW DIAMETER implant

NARROW DIAMETER implant ND NARROW DIAMETER implant TABLE OF CONTENTS ND - NARROW DIAMETER implant Implant characteristics page 04 Dental implant page 05 Open Tray Impression Transfer page 06 Titanium Abutments page 07 O-Ball

More information

Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants

Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants Select Part 2 Internal Tri-Channel Connection Replace Select NobelSpeedy Replace NobelReplace and compatible implants listed below Select Part 2 contains only the Tri-Channel Internal Connection compatible

More information

Premium Straight. Premium Straight Shorty. Premium Straight length range. from 7.00 mm to mm. Ø 3.30 mm Ø 3.80 mm Ø 4.25 mm Ø 5.

Premium Straight. Premium Straight Shorty. Premium Straight length range. from 7.00 mm to mm. Ø 3.30 mm Ø 3.80 mm Ø 4.25 mm Ø 5. Premium Straight Premium is the cylindrical implant with 17 years of clinical success and over 60 publications. All Premium Straight implants have a machined neck 0.80 mm high, a cylindrical shape and

More information

MICRODENT EXTERNAL CONNECTION PRODUCTS GUIDE EXTERNAL CONNECTION IMPLANTS IMPLANTOLOGY SYSTEMS. Product presentation. Digital information

MICRODENT EXTERNAL CONNECTION PRODUCTS GUIDE EXTERNAL CONNECTION IMPLANTS IMPLANTOLOGY SYSTEMS. Product presentation. Digital information Product presentation Digital information IMPLANTOLOGY SYSTEMS EXTERNAL CONNECTION PRODUCTS GUIDE www.microdentsystem.com Implant catalogues SYSTEM UNIVERSAL Implantes de conexión externa Other catalogues

More information

For technical assistance: Tel Working time: 8.30 am pm

For technical assistance: Tel Working time: 8.30 am pm I For technical assistance: Tel. +39 059 392827 Working time: 8.30 am - 5.30 pm Index JD Digital solutions for Intraoral Scanning JD Implant Libraries JD Guided Surgery Kit JD Surgical Guide and 3D Model

More information

NARROW DIAMETER implant

NARROW DIAMETER implant N NARROW IAMETER implant N Precision dental solutions C-Tech Implant is a dynamic company with aggressive growth, producing components and product lines primarily for dental implantology. International

More information

SwissPlant Prosthetic Catalog. SwissPlant

SwissPlant Prosthetic Catalog. SwissPlant SwissPlant Prosthetic Catalog Contoured Snap-On Angled Contoured Ball Attachment Gold/Plastic Castable Locator Attachment Plastic Temporary Screw Receiving Plastic Non-Engaging Castable Narrow Titanium

More information

Legacy Prosthetic Catalog

Legacy Prosthetic Catalog Legacy Prosthetic Catalog Straight Snap-On Straight Contoured Angled Contoured Ball Attachment Gold/Plastic Castable Locator Attachment Plastic Temporary Screw Receiving Plastic Non-Engaging Castable 15

More information

OT EQUATOR CASTABLE Single Attachment for Overdentures

OT EQUATOR CASTABLE Single Attachment for Overdentures OT EQUATOR CASTABLE Single Attachment for Overdentures pick-up impression OT EQUATOR PROFILE CASTABLE MALE ATTACHMENT individual tray RETENTIVE CAPS OT EQUATOR HOUSING VIOLET CAP RIGID RETENTION (2.7Kg)

More information

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G IQ IMPLANTS Smart Choice PRODUCT C ATA L O G www.iqimplants.com info@iqimplants.com 2 TABLE OF CONTENTS GENERAL Company Profile 3 IMPLANTS 5 PROSTHETICS 13 TOOLS 27 3 COMPANY PROFILE IQ Implants Ltd. reflects

More information

SURGICAL MANUAL GLOBAL

SURGICAL MANUAL GLOBAL SURGICAL MANUAL GLOBAL SURGICAL MANUAL INDEX Global implants 04 The range Patient history and treatment plan 30 12 Implant insertion Connection platform 72 14 References Surgical instruments 74 18 When

More information

Type 1. Type 2. Straumann Bone Level. The L-Series abutments are compatible with» L-SERIES «

Type 1. Type 2. Straumann Bone Level. The L-Series abutments are compatible with» L-SERIES « The L-Series abutments are compatible with L-SERIES «Bone Level DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments. Type 1 angled over flat Type 2 angled over

More information

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag. PROSTHESIS MANUAL INDEX PRESENTATION Pag. 05 CEMENT-SCREWED PROSTHESIS Pag. 12 INTRODUCTION PROSTHESIS MANUAL WARNINGS Pag. 06 Pag. 06 IMPRESSION TAKING: NECESSARY MATERIAL PROSTHESIS: NECESSARY MATERIAL

More information

Restoring Straumann implants. with Locator abutments.

Restoring Straumann implants. with Locator abutments. Restoring Straumann implants with Locator abutments. 1 1 Straumann is the industrial partner of the ITI (International Team for Implantology) in the areas of research, development, and education. Contents.

More information

S i m p l i c I t y, c o m f o r t, a e s t h e t i c s. axiom. The new dimension

S i m p l i c I t y, c o m f o r t, a e s t h e t i c s. axiom. The new dimension S i m p l i c I t y, c o m f o r t, a e s t h e t i c s axiom The new dimension 2 Implants by anthogyr axiom, t h e n e w g e n e r a t i o n i m p l a n t axiom characteristics represent the perfect synthesis

More information

EasyLineImplant. Guided Surgery

EasyLineImplant. Guided Surgery EasyLineImplant Guided Surgery Guided surgery Guided Surgery represents an improvement in the traditional surgery, increasing the advantages for clinicians and patients. The guided procedure allows reaching

More information

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray) INSTRUCTIONS FOR THE DENTIST synocta impression procedure, Screw-retained and Snap-on Screw-retained (Open tray) Snap-on (Closed tray) click 1. Attach synocta Impression caps to implants. Hand-tighten

More information

- RESTORATIVE PRODUCT CATALOG

- RESTORATIVE PRODUCT CATALOG - RESTORATIVE PRODUCT CATALOG MADE IN USA Others make Implants to sell... Tatum Surgical makes Implants to treat your Patients. Your Source for Implants To Meet Every Clinical Need Tatum... 4 Angled Post

More information

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

The LOCATOR concept. Simplicity and versatility for prosthesis fixation The concept Simplicity and versatility for prosthesis fixation The concept Experience the freedom in prosthesis fixation Simple and secure fixation of implant-supported prostheses is essential for successful

More information

HEXAGON Implant System

HEXAGON Implant System HEXAGON Implant System PRODUCT N 1 CATALOG 2018 2 Table of contents Implants... 4 Prosthetics Lab Components, Abutments... 5 Zest LOCATOR, R-Tx and F-Tx...6 Multi-Unit Abutments...7 Instruments...8 Zest

More information

Type 1. Type 2. Straumann Tissue Level. The N-Series abutments are compatible with» N-SERIES «

Type 1. Type 2. Straumann Tissue Level. The N-Series abutments are compatible with» N-SERIES « The N-Series abutments are compatible with N-SERIES «Tissue Level DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments. Type 1 angled over flat Type 2 angled over

More information

Prosthodontic Procedure

Prosthodontic Procedure Prosthodontic Procedure TSH BNT Regeneration Implant Systems CAD-CAM Digital Solutions Services Important: before using Phibo The innovative and patented design of the Phibo implant systems incorporates

More information

NARROW DIAMETER implant

NARROW DIAMETER implant NARROW IAMETER implant Impianto NARROW IAMETER Implant characteristics pag 04 ental Implants pag 06 Titanium healing abutments pag 06 Open tray impression transfer pag 07 Closed tray impression transfer

More information

US Implant System 2013 PROSTHETIC PROCEDURE

US Implant System 2013 PROSTHETIC PROCEDURE US Implant System 2013 PROSTHETIC PROCEDURE Contents TS Implant System Cement retained restoration 06 Cement retained bridges with the Cement abutment system 18 Cement retained crown with the Angled abutment

More information

SimpleLine II Surgical / Prosthesis Manual

SimpleLine II Surgical / Prosthesis Manual SimpleLine II Surgical / Prosthesis Manual SimpleLine II SURGICAL MANUAL Surgical Drill Sequence 04 Fixture Installation 05 Fixture Connection 06 Surgical Kit Maintenance 08 Warnings 09 04 SimpleLine ll

More information

MICROCONE. IPS Implant Systems

MICROCONE. IPS Implant Systems MICROCONE IPS Implant Systems CATALOGUE 2018 MICROCONE Surgery 10 Prosthetics 26 Prosthetic Tools 47 Accessories 50 4» With Microcone a unique implant system has been developed by MEDENTiKA providing

More information

N E W S M I L E S E V E R Y D AY

N E W S M I L E S E V E R Y D AY C ATA LO G 2 0 6 N E W S M I L E S E V E R Y D AY Neodent provides you with a complete range of products and services that are designed and produced by a team of professionals who truly love what they

More information

A fresh look at implantology

A fresh look at implantology A fresh look at implantology 2 Anthogyr introduces Axiom Multi Level In their quest for increasingly reliable, accessible and relevant solutions, the Anthogy yr team has devised a way to bring even more

More information

WE VE MADE FIXED FULL-ARCH RESTORATIONS A SNAP. NO SCREWS. NO CEMENT. NO COMPROMISES.

WE VE MADE FIXED FULL-ARCH RESTORATIONS A SNAP. NO SCREWS. NO CEMENT. NO COMPROMISES. WE VE MADE FIXED FULL-ARCH RESTORATIONS A SNAP. NO SCREWS. NO CEMENT. NO COMPROMISES. LOCATOR F-Tx A NEW WAY TO THINK ABOUT FIXED FULL-ARCH RESTORATIONS. LOCATOR F-Tx IS A SIMPLIFIED, TIME SAVING SOLUTION

More information

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER Product Catalogue 1 Product Chart Follow the lines to see which products that fits both diameters and which that are special. In true OSPOL philosophy, most of the instruments and abutments fits both diameters.

More information

InterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free

InterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free InterActive System Prosthetic Catalog simplycrown & bridge SMART PACK InterActive All-in-1 Packaging simplyinteractive Mount-Free CONICAL Cover Screws, Healing Collars & Transfers Replacement Surgical

More information

. Simplification. High Performance. Safety and Longevity. The fundamental goal is to restore the quality of life of patients.

. Simplification. High Performance. Safety and Longevity. The fundamental goal is to restore the quality of life of patients. Catalog 4 P-I product line was developed by te Osseointegration pioneer, Professor Per-Ingvar Brånemark, jointly wit experienced scientists in world recognized entities to meet modern implant dentistry

More information

RATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG A company of the KLINGEL GROUP

RATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG A company of the KLINGEL GROUP RATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG 0 A company of the KLINGEL GROUP Contents Universal ratchet without torque function General information All ratchets are available with different

More information

SwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD

SwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD SwishPlant System Catalog ------------ 4.1mmD ------------ 3.7mmD ------------ 3.3mmD SwishPlant 6.5mmD ------------ 6.5mmD ------------ 5.7mmD Table of Contents SwishPlant Fixture Mount Packaging Page

More information

GUIDED SURGERY TECHNIQUE

GUIDED SURGERY TECHNIQUE GUIDED SURGERY TECHNIQUE INDEX WORKFLOW...4 OUR SOLUTIONS...5 PLANNING PROTOCOL - PARTIAL EDENTULISM...6 - TOTAL EDENTULISM...9 SOFTWARE FEATURES...12 SURGICAL COMPONENTS FOR GUIDED IMPLANTOLOGY...14

More information

ESTHETIC LINE implant

ESTHETIC LINE implant EL ESTHETIC LINE implant EL ESTHETIC LINE implant TABLE OF CONTENTS EL - ESTHETIC LINE implant Implant characteristics page 04 Dental implants page 05 Closed tray impression transfer page 06 Open tray

More information

Ankylos. Product Catalog

Ankylos. Product Catalog Product Catalog General prosthetic advice for In order to obtain utmost benefit from the unique restorative features of the implant system, please observe the following guidelines: Avoid occlusal overload,

More information

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l Two-Piece ReActive Tri-Lobe Implants with Multi-Unit Abutments One-Piece ScrewIndirect Implants

More information

Implant System MAKE IT SIMPLE

Implant System MAKE IT SIMPLE Implant System MAKE IT SIMPLE P. 4-5 P. 6-7 P. 8-9 P. 10-13 P. 14 P. 15-17 P. 18-19 P. 20-21 MIS Warranty: MIS exercises great care and effort in maintaining the superior quality of its products. All MIS

More information

Biomimetic Product catalogue

Biomimetic Product catalogue Biomimetic Product catalogue 20 Pol. Industrial Santa Anna I Apartado 20 08251 Santpedor (Barcelona) España T. (+34) 902 38 38 48 F. (+34) 93 827 38 73 www.avinent.com avinent@avinent.com 1 CORAL is the

More information

4766 Research Dr. San Antonio, TX insightdentalsystems.com

4766 Research Dr. San Antonio, TX insightdentalsystems.com OVERVIEW OF THE INSIGHT DENTAL IMPLANT DELIVERY SYSTEM The IDS system comes in a unit dose implant system where its advantage provides sterile instrumentation in one single-use kit. It is organized to

More information

Straumann Dental Implant System. Fax Order Form Collection.*

Straumann Dental Implant System. Fax Order Form Collection.* Straumann Dental Implant System. Fax Order Form Collection.* * The NNC Fax Order Form is still a stand alone document due to the unique restorative portfolio Straumann USA, LLC Tissue Level Implants for

More information

product catalog

product catalog product catalog 2014-2015 02 Table of Contents About ADN 03 ntroduction About ADN... 3 Dental mplant Systems... 5 Surface Treatments... 6 nternal Conical Connection mplant Systems Touareg CloseFit mplant

More information

INTRODUCTION. Why Choose Cortex Prosthetics?

INTRODUCTION. Why Choose Cortex Prosthetics? Prosthetic Manual 4 INDEX Introduction 6-14 Impression Techniques 15-29 Abutments Selection Handling 30-33 Temporary Restorations 34-38 Screw Reiained Restorations 39-52 Removable Restorations 53-63 5

More information

WE VE MADE FIXED FULL-ARCH RESTORATIONS A SNAP.

WE VE MADE FIXED FULL-ARCH RESTORATIONS A SNAP. LOCATOR F-Tx A NEW WAY TO THINK ABOUT FIXED FULL-ARCH RESTORATIONS. LOCATOR F-Tx IS A SIMPLIFIED, TIME SAVING SOLUTION for fixed full-arch restorations with no compromise to prosthesis strength or esthetics.

More information

SURGICAL MANUAL. Shelta

SURGICAL MANUAL. Shelta SURGICAL MANUAL Shelta SURGICAL MANUAL CONTENTS THE IMPLANTS...4 Clinical indications for resorting to implantoprosthetic therapies...4 Side and secondary effects...5 General indications...6 Method of

More information

NEW NEW. An Extended Solution for Narrow Ridges

NEW NEW. An Extended Solution for Narrow Ridges NEW mm NEW An Extended Solution for Narrow Ridges NICE System: An Extended Solution for Narrow Ridges Quality Alpha-Bio Tec presents an advanced new NARROW implant solution for narrow alveolar ridges and

More information

SURGICAL MANUAL. Premium

SURGICAL MANUAL. Premium SURGICAL MANUAL Premium SURGICAL MANUAL TABLE OF CONTENTS IMPLANT SYSTEM... 4 Clinical indication for resorting to implantoprosthetic therapies...4 Side and secondary effects...5 General indications...6

More information

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants Very small abutment head easy and secure handling Ankylos The SmartFix concept Prosthetic solution on angled implants Stable prosthetic fit The area supporting the prosthesis is extended distally by the

More information

Legacy TM. System Catalog. Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4

Legacy TM. System Catalog. Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4 Legacy TM System Catalog Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4 Table of Contents Page # Design, Surface & Dimensions 1-5 6-13 Legacy TM 1, Legacy TM 2, Legacy TM 3 & Legacy TM 4 s Labeling &

More information

The intelligent system.

The intelligent system. The intelligent system. Contents This is isy The intelligent system 5 Cost efficient implant sets 7 Total flexibility 9 Purposeful simplicity 11 The digital future 13 Quality without compromise 15 isy

More information

the perfect fusion Catalogue

the perfect fusion Catalogue the perfect fusion Catalogue Valladolid, June 2014 Dear Doctors, We are pleased to introduce our new MG In-Hex Catalogue 2014. Castilla y León Young Businessman of the Year Award. Valladolid 2003 Established

More information

SMARTbase Beauty Done Better

SMARTbase Beauty Done Better SMARTbase Beauty Done Better Tools Legacy InterActive SMARTbase. Beauty Done Better. Implant Direct s SMARTbase CAD/CAM abutments combine superior aesthetics for your patients and more freedom of choice

More information

Stock Prosthetic Guide 2014

Stock Prosthetic Guide 2014 Stock Prosthetic Guide 2014 Straumann Variobase Versatile & Cost-effective Abutment Solution The new Straumann Variobase Abutment delivers a highly cost-effective solution for screw or cement-retained

More information

Where technology meets dentistry INNOVATION. at a GLANCE

Where technology meets dentistry INNOVATION. at a GLANCE Where technology meets dentistry INNOVATION at a GLANCE ABOUT PALTOP Paltop is a premium manufacturer of dental implants that strives to provide highest quality products in the dental arena. Leveraging

More information

Astra Tech Implant System. Product catalog. OsseoSpeed TX

Astra Tech Implant System. Product catalog. OsseoSpeed TX Astra Tech Implant System Product catalog OsseoSpeed TX Astra Tech Implant System CONTENTS Astra Tech Implant System 4 Product overview 3.0 5 Product overview 3.5/4.0 6 Product overview 4.5/5.0 8 Surgical

More information

CAD/CAM SMARTbase Beauty Done Better

CAD/CAM SMARTbase Beauty Done Better CAD/CAM SMARTbase Beauty Done Better Tools Legacy InterActive SMARTbase. Beauty Done Better. Implant Direct s SMARTbase CAD/CAM abutments combine superior aesthetics for your patient and more freedom of

More information

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants Multi-Unit Abutment System SIC Safe on Four Optimum use of available bone by angled placement of implants Multi-Unit Abutment System SIC Safe on Four Safe on Four The SIC Safe on Four system is a further

More information

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit a perfect fit IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS Open and closed impression-taking Impression-taking for option platform switching Bite registration Temporary

More information

CHECK-UP Determination of Impression type & Method after implant placement

CHECK-UP Determination of Impression type & Method after implant placement CHECK-UP Determination of Impression type & Method after implant placement Fixture level impression Abutment level impression Transfer impression Conventional method Pick-up impression Plastic impression

More information

Quick start Prosthetics

Quick start Prosthetics EN Quick start Prosthetics Easy and effective YELLOW PROSTHETIC PLATFORM QN CEMENTED RESTORATIONS ESTHETIC AUTMENTS OPEN TRAY POST IMPLANT ANALOG Indexed components with internal conical connection. 0.7

More information

Biomimetic PEARL. Product catalogue

Biomimetic PEARL. Product catalogue Biomimetic PEARL Product catalogue PEARL is the AVINENT system of mini implants, an innovative product with unique features that aims to provide a quality alternative to what is available today as regards

More information

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable. PRODUCT CATALOG Since 1985» Simple. Predictable. Profitable. 2014 IMPLANTS HEALING PLUG INSERTERS COLLAGEN PRODUCTS 3.0mm Well Integra-CP Part No. DIAMETER LENGTH Price 345-306 4.5mm mm $280.00 345-308

More information

PRODUCT CATALOG 2014 CONELOG IMPLANTATSYSTEM PRODUCT PRODUKTKATALOG CATALOG 2014

PRODUCT CATALOG 2014 CONELOG IMPLANTATSYSTEM PRODUCT PRODUKTKATALOG CATALOG 2014 PRODUCT CATALOG 2014 CONELOG IMPLANTATSYSTEM PRODUCT PRODUKTKATALOG CATALOG 2014 Valid from May 2014 ADDED VALUE THROUGH COMPETENCE IN IMPLANTOLOGY A partnership with CAMLOG encompasses the exceptional

More information

For the oral rehabilitation

For the oral rehabilitation For the oral rehabilitation Contents For superstructures Chapter 1 Overview of prosthetic modes 1. Prosthetic modes of the PLATON system 2. Factors involved in prosthetic design Chapter 2 Cement-retained

More information

SIMPLE INSERTION, NATURAL STABILITY. Self-cutting capacity in both directions Makes it possible to achieve high primary stability with low torque

SIMPLE INSERTION, NATURAL STABILITY. Self-cutting capacity in both directions Makes it possible to achieve high primary stability with low torque JD EVOLUTION PLUS+ SIMPLE INSERTION, NATURAL STABILITY. FEATURES ADVANTAGES Internal hex connection with lead-in bevel, 100% compatible with Zimmer Screw-Vent The Connection is universally recognized by

More information

Product Catalog 2017/2018. Straumann International Edition

Product Catalog 2017/2018. Straumann International Edition Product Catalog 2017/2018 Straumann International Edition Note A list of abbreviations can be found on the reverse of this fold-out page. List of abbreviations -04 Pack of 4 ABS ADLC Al AS BL BLT EDTA

More information

simply simply digital simply crown & bridge simply removable simply fixed simply à la carte

simply simply digital simply crown & bridge simply removable simply fixed simply à la carte TM crown & bridge fixed removable digital à la carte imagine... being able to order the way you treatment plan so you can focus on the dentistry, rather than the components knowing your treatment costs

More information

Prosthodontic Procedure

Prosthodontic Procedure Prosthodontic Procedure Aurea Regeneration Implant Systems CAD-CAM Digital Solutions Services AUREA IMPLANT SYSTEM PROSTHODONTIC PROCEDURE IMPORTANT BEFORE USING AUREA IMPLANT SYSTEM The innovative and

More information

RDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED

RDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED RDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED Introducing the new CIT Implant C ONFIDENCE I NSPIRING T ECHNOLOGY see more page.10 RDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED TABLE OF CONTENTS

More information

Prosthodontic Procedure

Prosthodontic Procedure Prosthodontic Procedure TSA TSA Advance Regeneration Implant Systems CAD-CAM Digital Solutions Services IMPORTANT: BEFORE USING Phibo The innovative and patented design of the Phibo implant systems incorporates

More information

RePlant System Prosthetic Catalog

RePlant System Prosthetic Catalog RePlant System Prosthetic Catalog Healing Collars, Transfers, Analogs & Alignment Tools Healing Collars Components include Dual-Grip feature for use with 1.25mmD Hex Tool or Nobel Unigrip ScrewDriver Width

More information

FOR PROFESSIONALS. Product Catalogue. Cochlear Vistafix 3 System A BONE ANCHORED PROSTHETIC SOLUTION

FOR PROFESSIONALS. Product Catalogue. Cochlear Vistafix 3 System A BONE ANCHORED PROSTHETIC SOLUTION FOR PROFESSIONALS Product Catalogue Cochlear Vistafix 3 System A BONE ANCHORED PROSTHETIC SOLUTION 1 The Vistafix 3 System consists of: Cochlear Vistafix VXI300 Implant (Vistafix 3 Implant) Cochlear Vistafix

More information

How something small, can make such a big difference!! Your best choice in overdenture

How something small, can make such a big difference!! Your best choice in overdenture How something small, can make such a big difference!! Your best choice in overdenture Why? Kerator has the worldʼs most powerful competitiveness in overdenture attachment system. KERATOR was chosen over

More information

IMPRESSION PROCEDURES TRAINING MANUAL

IMPRESSION PROCEDURES TRAINING MANUAL IMPRESSION PROCEDURES TRAINING MANUAL 01 01 A.B. DENTAL A.B. Dental is proud to present this impression taking procedure protocol. This manual explains, step by step, the procedure while using A.B. Dental

More information

isy indications and techniques

isy indications and techniques This is isy 3 The isy Implant System demonstrates its unique talents in numerous indications. Its intelligence allows the clinician to focus on what is most common in their everyday implant practice. isy

More information

PHILOSOPHY SWISS QUALITY PERFORMANCE

PHILOSOPHY SWISS QUALITY PERFORMANCE SYSTEM OVERVIEW PHILOSOPHY TRI Dental Implants is an innovative provider of dental implant solutions from Switzerland. Join our unique approach in implant dentistry! Founder & CEO Tobias S. Richter 100%

More information

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments

UDELL DENTAL LABORATORY Instructions for Use PREAT Precision Attachments Indications Instructions The Locator Root Attachment is designed for use with overdentures or partial dentures, retained in whole or in part by endodontically treated roots in the mandibular or maxilla.

More information

PRAMA. Surgical Manual

PRAMA. Surgical Manual PRAMA Surgical Manual Prama The implants Clinical indications for resorting to implantoprosthetic therapies Side and secondary effects General indications Method of use Prama implants Prama RF implants

More information

NobelParallel Conical Connection Product overview

NobelParallel Conical Connection Product overview NobelParallel Conical Connection Product overview Access to innovative restorative solutions Take advantage of innovative solutions available only for the internal conical connection, such as the cement-free

More information

External Hexagon Hybrid Implants. External Hexagon Hybrid Implants. Versatility.

External Hexagon Hybrid Implants. External Hexagon Hybrid Implants. Versatility. External Hexagon Hybrid Implants Versatility. www.pibranemark.com HEX-S Solid Enhanced Macrogeometry Easy, Safe and Simplified installation (!). Special Conical Drills have the same geometry of Hybrid

More information

C O M PA N Y P R O F I L E S I N C E W E H AV E B E E N H E L P I N G D E N T I S T S T O M A K E T H E I R PAT I E N T S S M I L E

C O M PA N Y P R O F I L E S I N C E W E H AV E B E E N H E L P I N G D E N T I S T S T O M A K E T H E I R PAT I E N T S S M I L E C O M PA N Y P R O F I L E SINCE 1977 W E H AV E B E E N H E L P I N G D E N T I S T S T O M A K E T H E I R PAT I E N T S S M I L E A LONG ROAD DEDICATED TO IMPLANTOLOGY With over 40 years of experience

More information

Osteoconductive S.L.A. Surface. Fantastic surface, Bioseal, and Perfect achievement of CMI f ixation.

Osteoconductive S.L.A. Surface. Fantastic surface, Bioseal, and Perfect achievement of CMI f ixation. Fantastic surface, Bioseal, and Perfect achievement of CMI f ixation. Osteoconductive S.L.A. Surface No residual acid and cytotoxicity were observed in the surface examination. IS-II active Product Catalog

More information

SuperLine & Implantium Surgical / Prosthesis Manual

SuperLine & Implantium Surgical / Prosthesis Manual SuperLine & Implantium Surgical / Prosthesis Manual SuperLine & Implantium SURGICAL MANUAL Surgical Drill Sequence I 04 Surgical Drill Sequence II 06 Drilling Depth Guide 08 Fixture Connection 10 Installation

More information

Prothesis. For SHELTA implants

Prothesis. For SHELTA implants Prothesis For SHELTA implants XA posts for cemented prosthesis These posts, made of Gr. 5 titanium, allow cemented prosthesis to be fitted using the One-Abutment-One-Time technique, in which the XA post

More information

3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38).

3. Insert Tocar Sleeves Insert the NCB tissue protection sleeve assembly 1.6 to 10mm through a skin incision (Fig. 38). NCB Proximal Humerus Plating System Surgical Technique 19 2. Temporary Plate Fixation The plate can be temporary fixed to the bone with 1.6mm K-wire through the proximal cannulated fixation screw of the

More information

PRODUCT INFORMATION FOR CORTEX ABUTMENTS AND OTHER RESTORATIVE COMPONENTS

PRODUCT INFORMATION FOR CORTEX ABUTMENTS AND OTHER RESTORATIVE COMPONENTS PRODUCT INFORMATION FOR CORTEX ABUTMENTS AND OTHER RESTORATIVE COMPONENTS The Cortex Implants are intended for single or multiple replacements of lost teeth and provide a way to attach the prosthetic pieces

More information

prosthetic technique manual

prosthetic technique manual prosthetic technique manual table of contents table of contents introduction modules why choose BioHorizons prosthetics? surgical and prosthetic options & impression technique overview impression technique

More information

» Guided Surgery. by MEDENTiKA « MEDENTIGUIDE SURGERY MANUAL QUATTROCONE QUATTROCONE30. IPS Implant systems

» Guided Surgery. by MEDENTiKA « MEDENTIGUIDE SURGERY MANUAL QUATTROCONE QUATTROCONE30. IPS Implant systems » Guided Surgery by MEDENTiKA «IPS Implant systems MEDENTIGUIDE QUATTROCONE QUATTROCONE30 SURGERY MANUAL » MedentiGuide «MedentiGuide drill sleeves support the surgeon in preparing the implant bed for

More information

High-end solution STEP-BY-STEP USER GUIDE

High-end solution STEP-BY-STEP USER GUIDE High-end solution STEP-BY-STEP USER GUIDE System Contents REAL TIME Restoration Guided Conical drill Multi-Unit abutment, Conical connection Guided kit for conical connection implant procedure C1 & V3

More information