Cross-section dimensions and mechanical properties of esthetic orthodontic coated archwires

Size: px
Start display at page:

Download "Cross-section dimensions and mechanical properties of esthetic orthodontic coated archwires"

Transcription

1 ORIGINAL ARTICLE Cross-section dimensions and mechanical properties of esthetic orthodontic coated archwires Dayanne Lopes da Silva, a Claudia Trindade Mattos, b Eduardo Franzotti Sant Anna, c Ant^onio Carlos de Oliveira Ruellas, c and Carlos Nelson Elias d Rio de Janeiro, Brazil Introduction: There has been continuing interest in the development and use of esthetic and effective orthodontic archwires. The aims of this study were to evaluate the inner alloy core dimensions of 4 brands of as-received esthetic coated wires and their mechanical properties before and after 21 days of oral exposure, compared with conventional stainless steel and nickel titanium wires. Methods: Four groups (Ortho Organizers, Carlsbad, Calif; TP Orthodontics, LaPorte, Ind; Orthometric, Beijing, China; and Trianeiro, Rio Claro, S~ao Paulo, Brazil) of orthodontic archwires were tested. Five properties were evaluated: inner wire dimensions, modulus of elasticity, modulus of resilience, maximum deflection force, and load deflection curve characteristics. Images of the transverse sections from the specimens were made with a stereoscope. The inner alloy core dimensions of each wire were measured by using Image Pro Plus software (version 4.5; Media Cybernetics, Silver Spring, Md). All specimens were tested in a universal testing machine in a 3-point bending test. Results: Coated wires of the Ortho Organizers and Trianeiro groups showed greater reductions in their inner alloy core dimensions and produced lower loading and unloading forces and lower modulus of elasticity, modulus of resilience, and maximum deflection force values than did their control wires. Inner alloy core dimensions and the mechanical behavior of coated wires practically did not differ from the control wires in the TP Orthodontics and Orthometric groups. Conclusions: The reduction on the inner alloy core dimensions to compensate for the coating thickness seems to be the variable responsible for greater changes in the mechanical properties of esthetic coated wires. (Am J Orthod Dentofacial Orthop 2013;143:S85-91) Much progress has been made in the development of esthetic clear and translucent brackets for use in labial orthodontics. 1 However, the most effective wires continue to be manufactured from efficient metal alloys. They have the flexibility, strength, and chemical resistance needed for orthodontic purposes. Nevertheless, they are clearly visible to observers, and patients with esthetic brackets might resist their use. a PhD student, Department of Orthodontics, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil. b Substitute professor, Department of Orthodontics, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil. c Professor, Department of Orthodontics, Universidade Federal do Rio de Janeiro, Rio de Janeiro, Brazil. d Professor, Department of Mechanical Engineering and Materials Science, Instituto Militar de Engenharia, Rio de Janeiro, Brazil. The authors report no commercial, proprietary, or financial interest in the products or companies described in this article. Reprint requests to: Ant^onio Carlos de Oliveira Ruellas, Av. Professor Rodolpho Paulo Rocco, 325, Ilha do Fund~ao, Rio de Janeiro, Rio de Janeiro, CEP: , Brazil; , antonioruellas@yahoo.com.br. Submitted, May 2012; revised and accepted, September /$36.00 Copyright Ó 2013 by the American Association of Orthodontists. Metallic archwires coated with colored polymers or inorganic materials are currently the solution to this esthetic problem. 2 Materials used in coating are polymers such as synthetic fluorine-containing resin or epoxy resin composed mainly of polytetrafluoroethylyene, which is used to simulate tooth color. 3 The process of applying this coating to the archwire includes some surface treatment on the wire and the use of clean compressed air as a transport medium for the atomized polytetrafluoroethylyene particles to coat the wire. The set is further heat treated in a chamber furnace. 4 The mechanical properties of metallic archwires could be affected during this process and by possible changes on their inner alloy core dimensions to compensate for the thickness of the coating layer. The mechanical properties of orthodontic archwires can be assessed by using a 3-point bending test, which evaluates the load-deflection properties, considered the most important parameters to determine the biologic nature of tooth movement, 5 and provides information on the behavior of wires when subjected to deflection in the horizontal and vertical directions. 6,7 No studies S85

2 S86 Silva et al Table I. Characteristics of the archwires used in the study Group Manufacturer Cross-section size (in) Composition Coating surface I Ortho Organizers, Carlsbad, Calif Control: Pro Form Shiny Bright Stainless steel (CrNi) - Coated: Tooth Tone Plastic Coated All surfaces II TP Orthodontics, LaPorte, Ind Control: Shiny Bright Stainless steel (CrNi) - Coated: Aesthetic Shiny Bright Labial III Orthometric, Beijing, China Control: Flexy Super Elastic NiTi - Coated: Esthetic Flexy Super Elastic Labial IV Trianeiro, Rio Claro, S~ao Paulo, Brazil Control: NiTi wire NiTi - Coated: Coated wire NiTi All surfaces CrNi, Chromium-nickel; NiTi, nickel-titanium. have been conducted to examine the inner alloy core dimensions of esthetic coated stainless steel and nickel-titanium archwires and their mechanical properties after oral exposure. The aims of this research were to investigate the inner alloy core dimensions of as-received esthetic coated archwires and their mechanical properties (3-point bending test) before and after oral exposure, compared with conventional stainless steel and nickel-titanium archwires. MATERIAL AND METHODS Sample size calculations were performed for each test. A sample size of at least 5 wire segments per group was required to detect a difference of of an inch in the dimensions between the coated and the control wires, with a standard deviation of , a significance level of 5%, and a test power of Based on the results from a pilot study, a sample size calculation was performed showing that at least 5 as-received and 10 postclinical wire segments would be enough to detect a 10% difference in the mechanical properties tested in this study with a significance level of 5% and a test power of Four brands of esthetic coated archwires (Ortho Organizers, Carlsbad, Calif; TP Orthodontics, LaPorte, Ind; Orthometric, Beijing, China; and Trianeiro, Rio Claro, S~ao Paulo, Brazil) were tested, and their respective control counterparts (conventional stainless steel and nickel-titanium archwires) were evaluated (Table I). The sample included 176 wire segments at least 20 mm in length. Eighty wire segments were from asreceived archwires (5 specimens of each kind of wire used to measure the inner alloy core dimensions, and 5 were used in the 3-point bending test), and 96 segments (12 specimens of each kind of wire used in the 3-point bending test) were retrieved after 21 days in oral cavities. The retrieved wire segments were obtained from 12 subjects. Ethical approval was obtained for this investigation from the ethics in research committee of the Institute of Public Health Studies from the Federal University of Rio de Janeiro in Brazil (process ). Informed consent form was signed by all patients who met the following criteria: good oral hygiene, no caries, and no systemic changes. Two metal brackets (Morelli, Sorocaba, S~ao Paulo, Brazil) were bonded to teeth on each hemiarch with a distance between them of at least 20 mm. The coated wire segment was tied into the slot, and its control wire segment was tied juxtaposed to the upper base of the brackets wings by using stainless steel in ligatures (Morelli) and ligature pliers (Fig 1). A split-mouth design was used in all groups. The groups were allocated randomly to each hemiarch by using random number tables. The generator and executor of the randomization were separate persons (C.T.M. and D.L.S.). Oral hygiene instructions were given, and the patients used the same types of toothbrush, toothpaste, and dental floss throughout the study. The subjects were told not to use any other oral agents, including oral irrigators or antimicrobial mouthrinses. In every participant, the specimens were placed and removed by the same operator (D.L.S.). The subjects were not aware of which wire was placed in each quadrant in the mouth. Since the colors of the coated wires differed slightly from brand to brand, it was not possible to blind the operator to the types of coated wire. After 21 days, the wire segments were removed and individually placed in an ultrasound cleaner (Cristofoli; Campo Mour~ao, Parana, Brazil) immersed in a multiuse detergent (Amway, Ada, Mich) for 30 minutes, so that organic debris could be removed. The same procedure was used for the as-received specimens. After in-vivo clinical exposure, all samples were subjected to mechanical testing. April 2013 Vol 143 Issue 4 Supplement 1 American Journal of Orthodontics and Dentofacial Orthopedics

3 Silva et al S87 Fig 1. Orthodontic appliances in the oral environment: A, frontal view; B, side view. C, Control wire segment; E, esthetic coated wire segment. Fig 2. Stereoscope images of inner alloy core height and width (3 measurements of each kind): A, group I (Ortho Organizers) coated wire; B, group I control wire. Original magnification, 45 times. Five as-received wires were taken from each group and included, with their transverse section facing up, in plastic tubes (height, 10 mm; diameter, 5 mm) filled with light-curing composite resin (Monolok 2 ; Rocky Mountain Orthodontics, Denver, Colo). Then the samples were ground in a water-cooled polishing machine (Politriz DP-9U2; Struers A/S, Copenhagen, Denmark) with 360-, 400-, 600-, and 1200-grit abrasive papers under refrigeration. The images of the transverse section from each specimen were made with a stereoscope at 45 times magnification (model SZ61; Olympus, Tokyo, Japan). The inner alloy core height and width (3 measurements of each kind) of each wire were measured by using Image Pro Plus software (version 4.5; Media Cybernetics, Silver Spring, Md) (Fig 2). A total of 60 readings, including height and width, were measured in each group. The wires were tested according to a 3-point bending test (ISO 15841). The span length of 10 mm, the crosshead speed of 6.0 mm per minute, and the radii of the fulcrum and the indenter of 0.1 mm were used as suggested by the ISO standardization for orthodontic wire mechanical tests. The load was applied with a 50-N load cell in a universal testing machine (model DL 10000; Emic, Parana, Brazil) to the middle of the specimens, and the flexural strength values were recorded with Tesc software (Emic). Deflection was carried out with a centrally placed indenter moved by a computercontrolled stepper motor. Five as-received and 12 postclinical specimens for control and coated wires of each group were tested for a deflection of 3.1 mm, the force was registered, and the hysteresis curves produced on the chart s recorder were compared. For stainless steel wires, the testing was performed at room temperature, and for nickel-titanium wires at 37 C. The modulus of elasticity was calculated in the linear portion of force-deflection curves of each specimen using the equation American Journal of Orthodontics and Dentofacial Orthopedics April 2013 Vol 143 Issue 4 Supplement 1

4 S88 Silva et al Table II. Means, standard deviations, and P values of independent-samples t test between control and coated wires in each group for wire dimensions (in) Measured inner alloy core dimensions Control 3 coated Stated dimensions Height Width Height Width Group Height Width Mean 6 SD Mean 6 SD P value P value I Control \0.001 \0.001 Coated II Control Coated III Control \0.001 Coated IV Control \0.001 \0.001 Coated Table III. Comparisons of modulus of elasticity, modulus of resilience, and maximum deflection force of as-received and postclinical control and coated wires in each group Modulus of elasticity (GPa) Mean 6 SD Modulus of resilience (N.mm) Mean 6 SD Maximum deflection force (N) Mean 6 SD Group As-received Postclinical As-received Postclinical As-received Postclinical I Control (10.0)aA (7.12)bA 4.15 (0.11)aA 5.30 (0.18)bA (0.23)aA (0.27)bA Coated (4.21)aB (6.31)aB 3.72 (0.09)aB 4.44 (0.25)bB (0.29)aB (0.34)bB II Control (2.54)aA (6.05)bA 2.63 (0.05)aA 5.45 (0.42)bA (0.28)aA (0.50)bA Coated (5.83)aA (13.34)bA 2.70 (0.04)aA 3.34 (0.17)bB (1.04)aA (0.33)bB III Control (10.50)aA (3.59)aA (0.29)aA (1.09)aA (0.19)aA (0.53)bA Coated (13.54)aA (5.57)aA (1.23)aA (0.57)aA (0.75)aA (0.44)aA IV Control (2.89)aA (4.70)bA (0.53)aA (0.35)bA (0.07)aA (0.24)aA Coated (3.38)aB (6.41)aB (1.05)aB (0.20)aB 9.77 (0.17)aB 9.97 (0.23)aB a and b, Different letters mean a statistically significant difference (P\0.05) between as-received and postclinical samples in each group (same line). A and B, Different letters mean a statistically significant difference (P \0.05) between control and coated wires of each kind, as-received or postclinical (same column). E5 PL3 4BH 3 F ; where P is load, L is span length, B is wire width, H is wire height, and F is deflection. Resilience was measured by the modulus of resilience and expressed as the amount of elastic strain energy per unit of volume. This modulus was computed by integrating the area under the linear portion of the stress deflection diagram with OriginPro software (version 8.0; OriginLab, Northampton, Mass). Statistical analysis A standard statistical software package (version 16.0; SPSS, Chicago, Ill) was used for data analysis. The Kolmogorov-Smirnov test was applied to verify the normality of the results, and the independent-samples t test was used to compare the coated and control wires of each brand and to compare the as-received and postclinical samples of each kind of wire. RESULTS Measured inner alloy core and nominal cross-section dimensions for as-received coated and control wire segments used in this investigation are shown in Table II.In general, most measured values for coated wires were smaller than the nominal sizes given by the manufacturers, and there was a significant difference between the control and the coated cross-section dimensions. April 2013 Vol 143 Issue 4 Supplement 1 American Journal of Orthodontics and Dentofacial Orthopedics

5 Silva et al S89 Fig 3. Average force-deflection curves for each group of as-received and postclinical samples. Group II (TP Orthodontics) was the only one that practically maintained the nominal sizes, and there was no significant difference between the control and coated cross-section dimensions in this group. Coated wires from group III (Orthometric) showed an average reduction of only in in their stated width. There were further reductions in both height and width of coated wires in groups I (Ortho Organizers) and IV (Trianeiro), when compared with the stated dimensions. Table III shows the mean values, standard deviations, and comparisons of modulus of elasticity, modulus of resilience, and maximum deflection force for control and coated wire segments in each group, both for asreceived and postclinical specimens. As-received and postclinical coated wires in groups I (Ortho Organizers) and IV (Trianeiro) showed lower modulus of elasticity, modulus of resilience, and maximum deflection force values when compared with their controls. No significant differences in modulus of elasticity and maximum deflection force values between the control and coated wires were observed in group II (TP Orthodontics). However, lower modulus of resilience values were observed in the as-retrieved coated wire segments in this group when compared with their controls. Group III (Orthometric) showed no significant differences between the control and coated wires in the mechanical properties evaluated in all times tested. The representative bending plots for as-received and postclinical coated and control wires of each group are shown in Figure 3. The bending curves for as-received and postclinical control and coated wire segments in groups II (TP Orthodontics) and III (Orthometric) were similar. However, there were considerable general differences in bending deformation behavior for the control and coated wire segments in groups I (Ortho Organizers) and IV (Trianeiro). In these groups, coated wires produced lower loading and unloading forces than did the control wires. DISCUSSION The performance of an archwire depends on the wire material and its cross-sectional geometry. Smaller American Journal of Orthodontics and Dentofacial Orthopedics April 2013 Vol 143 Issue 4 Supplement 1

6 S90 Silva et al archwires are selected to ensure lower forces in the initial stage of fixed appliance mechanotherapy, but they result in inadequate control of tooth movement, since there would be much play between the wire and the bracket. 8 In the final stages, it is necessary to obtain better engagement between the wire and the bracket with larger wires for better control of tooth movement. Thus, wire dimension is a critical and important component in force delivery, but manufacturers differ in their abilities to produce wires accurately Among the wires measured, those from TP Orthodontics were the only ones that practically maintained the nominal sizes, and there was no significant difference between control cross-section dimensions and coated inner alloy core dimensions. In general, most inner alloy core dimensions measured for the coated wires were smaller than the nominal sizes given by the manufacturers, and there was a significant difference between the control and coated cross-section sizes. The archwires with coating on all surfaces from groups I (Ortho Organizers) and IV (Trianeiro) showed the greatest reductions in their inner alloy core height and width compared with the stated dimensions (Table II). In one of the 2 groups with coating only on the vestibular surface (group III, Orthometric), the inner alloy core width was different from the stated width (Table II). Coated wires can have smaller inner alloy core dimensions to compensate for the thickness of the coating layer. That is why both height and width might be affected when all surfaces receive a coating layer, and width is sometimes affected when only the vestibular surface is coated. However, clinicians must be aware that manufacturers generally state the cross-section dimensions of the archwires, including the coating thickness, and not the real size of only the stainless steel or nickel-titanium material. Therefore, these archwires are not expected to have a mechanical behavior similar to an uncoated archwire with the same dimensions. Changes in the stated wire dimensions might influence torsional clearance and stiffness. 9,10 Many orthodontists are likely to use the nominal wire size as their guide in some clinical situations. The results from this study highlight the importance of considering larger nominal wire size than would normally be selected when using archwires with all surfaces coated. Because the amount of torsional clearance between wire and bracket depends on the slot and wire dimensions, as well as the degree of wire rounding, an undersized wire results in poorer fit in the bracket slot and might lead to less control during tooth movement. 12 The advantages of a 3-point bending test are the close simulation to clinical applications and its ability to differentiate wires with superelastic properties. 5 In addition, it offers a high degree of reproducibility that facilitates comparisons between studies. 13 This test produced load-deflection diagrams consisting of an upper loading curve and a lower unloading curve. The loading curve represents the force needed to engage the wire in the bracket, whereas the unloading curve represents the forces delivered to the teeth during treatment stages. 14 The modulus of elasticity corresponds to the elastic stiffness or the rigidity of the material. 15 Increased values indicate stiffer wires. 11 Modulus of resilience is the ability of a material to store energy when deformed elastically and to deliver it when the strain is removed. 15 Resilience tells the orthodontist how much potential energy can be recovered from the wire. In this study, for comparisons, the wire configuration and the alloy used in the manufacture of the control and coated archwires in each group were identical. These results show differences between the stated and the measured dimensions mainly in the coated wires. Furthermore, there are variabilities with respect to mechanical properties in the control and coated wires. Asreceived and postclinical coated wires in groups I (Ortho Organizers) and IV (Trianeiro) showed lower modulus of elasticity, modulus of resilience, and maximum deflection force values when compared with their controls (Table III). The analysis of the bending curves in these groups showed that coated wires produced lower loading and unloading forces than did the control wires (Fig 3). These archwires with a coating layer on all surfaces showed greater reductions in their inner alloy core dimensions; this could explain their different mechanical behavior. These results agree with those of Elayyan et al, 2 where coated wires also showed lower loading and unloading forces compared with uncoated wires, and the authors suggested that it was almost certainly because of the decrease in the size of the active nickel-titanium wires in them. However, the authors did not measure the cross-section size of the wires and evaluated only 1 type of archwire. On the contrary, inner alloy core dimensions of coated wires in group II (TP Orthodontics) practically did not differ from the control wires. In group III (Orthometric), only a decrease in width, where the coating was applied, was noted. Both groups had a coating layer only on the archwire s labial surface. The bending curves for these groups were similar when comparing as-received and postclinical control and coated wires (Fig 3). The major point an orthodontist should consider when selecting a particular wire size is the stiffness of the wire or its load-deflection rate. These differences in the mechanical properties between coated and control wires are probably due to deviations from stated sizes, or variations in material properties and the method of April 2013 Vol 143 Issue 4 Supplement 1 American Journal of Orthodontics and Dentofacial Orthopedics

7 Silva et al S91 applying the coating layer on the wires; this might have been heat treatment. Small changes in cross-section size produce large changes in the load deflection. 11 Ideally, manufacturers should keep inner alloy core dimensions the same and apply a coating layer on the labial surface of the wire that does not compromise its actual size, as shown in group II (TP Orthodontics). In other words, it would be appropriate for orthodontists to have at their disposal coated esthetic archwires with their real metallic dimensions matching their stated dimensions and thus having the same properties as identical solid stainless steel or nickel-titanium wires. Moreover, a coating layer only on the labial surface, which would not be in contact with brackets, could probably provide better bracket-wire engagement with no interference from this layer. CONCLUSIONS 1. Groups with a coating layer on all surfaces showed greater reductions in their inner alloy core dimensions to compensate for the thickness of the coating layer. These as-received and postclinical coated wires produced lower loading and unloading forces and lower modulus of elasticity, modulus of resilience, and maximum deflection force values than did their control wires. 2. The mechanical behavior of the groups whose inner alloy core dimensions practically did not differ from the control wires was similar when comparing the asreceived and postclinical control and coated wires. 3. The reduction of the inner alloy core dimensions seems to be the variable responsible for greater changes in the mechanical properties of coated archwires, along with variations in the materials properties. REFERENCES 1. Russell JS. Aesthetic orthodontic brackets. J Orthod 2005;32: Elayyan F, Silikas N, Bearn D. Mechanical properties of coated superelastic archwires in conventional and self-ligating orthodontic brackets. Am J Orthod Dentofacial Orthop 2010;137: Ramadan AA. Removing hepatitis C virus from polytetrafluoroethylyene-coated orthodontic archwires and other dental instruments. East Mediterr Health J 2009;9: Husmann P, Bourauel C, Wessinger M, J ager A. The frictional behavior of coated guiding archwires. J Orofac Orthop 2002;63: Krishnan V, Kumar K. Mechanical properties and surface characteristics of three archwire alloys. Angle Orthod 2004;74: Kapila S, Sachdeva R. Mechanical properties and clinical applications of orthodontic wires. Am J Orthod Dentofacial Orthop 1989;96: Walker M, White R, Kula K. Effect of fluoride prophylactic agents on the mechanical properties of nickel-titanium-based orthodontic wires. Am J Orthod Dentofacial Orthop 2005;127: Juvvadi SR, Kailasam V, Padmanabhan S, Chitharanjan AB. Physical, mechanical, and flexural properties of 3 orthodontic wires: an in-vitro study. Am J Orthod Dentofacial Orthop 2010;138: Meling T, Ødegaard J, Meling E. On mechanical properties of square and rectangular stainless steel wires tested in torsion. Am J Orthod Dentofacial Orthop 1997;111: Meling T, Ødegaard J. On the variability of cross-sectional dimensions and torsional properties of rectangular nickel-titanium arch wires. Am J Orthod Dentofacial Orthop 1998;113: Burstone CJ. Variable-modulus orthodontics. Am J Orthod 1981; 80: Meling T, Ødegaard J, Meling E. A theoretical evaluation of the influence of variation in bracket slot height and wire rounding on the amount of torsional play between bracket and wire. Kieferorthopadische Mitteilungen 1993;7: Wilkinson PD, Dysart PS, Hood JA, Herbison GP. Load-deflection characteristics of superelastic nickel-titanium orthodontic wires. Am J Orthod Dentofacial Orthop 2002;121: Segner D, Ibe D. Properties of superelastic wires and their relevance to orthodontic treatment. Eur J Orthod 1995;17: Brantley WA. Orthodontic wires. In: Brantley WA, Eliades T, editors. Orthodontic materials: scientific and clinical aspects. Stuttgart, Germany, and New York: Thieme; p American Journal of Orthodontics and Dentofacial Orthopedics April 2013 Vol 143 Issue 4 Supplement 1

Comparative analysis of load/deflection ratios of conventional and heat-activated rectangular NiTi wires

Comparative analysis of load/deflection ratios of conventional and heat-activated rectangular NiTi wires Comparative analysis of load/deflection ratios of conventional and heat-activated rectangular NiTi wires Fabio Schemann-Miguel 1, Flávio Cotrim-Ferreira 2, Alessandra Motta Streva 3, Alexander Viégas de

More information

Comparison of mechanical properties of beta-titanium wires between leveled and unleveled brackets: an in vitro study

Comparison of mechanical properties of beta-titanium wires between leveled and unleveled brackets: an in vitro study Insabralde et al. Progress in Orthodontics 2014, 15:42 RESEARCH ARTICLE Comparison of mechanical properties of beta-titanium wires between leveled and unleveled brackets: an in vitro study Open Access

More information

With judicious treatment planning, the clinical

With judicious treatment planning, the clinical CLINICIAN S CORNER Selecting custom torque prescriptions for the straight-wire appliance Earl Johnson San Francisco, Calif Selecting custom torque prescriptions based on the treatment needs of each patient

More information

wiirre e a a n n d d w wiirre e ffo orrms ms

wiirre e a a n n d d w wiirre e ffo orrms ms wire and wire forms wire and wire forms wire and wire forms Leone orthodontic wires are available in a range of alloys and different grades of elasticity and hardness to meet any therapeutic requirements.

More information

The Loading And Unloading Properties Of Various Arch Wires As A Function Of Cross Sectional Dimension And Inter Bracket Span Width System

The Loading And Unloading Properties Of Various Arch Wires As A Function Of Cross Sectional Dimension And Inter Bracket Span Width System The Loading And Unloading roperties Of Various Arch Wires As A Function Of Cross Sectional Dimension And Inter Bracket Span Width System Authors: Thomas Mathew MDS Orthodontics, Lecturer, Faculty of Dentistry,

More information

SE NiTi Heat Activated NiTi Ultra T Heat Activated NiTi Stainless Steel Beta Titanium. Ultra T Archwires

SE NiTi Heat Activated NiTi Ultra T Heat Activated NiTi Stainless Steel Beta Titanium. Ultra T Archwires S1:1 170421 7390 SOLITAIRE Single Pack s OrthoQuest offers the highest quality wires available in the orthodontic industry. Our wires are designed to exact specifications by trained engineers and manufactured

More information

Table of Contents Section 7 Table of Contents

Table of Contents Section 7 Table of Contents Table of Contents Section 7 Table of Contents archwire products 7 3M Unitek Nitinol Heat-Activated Archwire... 7.6 3M Unitek Nitinol Super-Elastic Archwire... 7.7 3M Unitek Nitinol Classic Archwire...

More information

Load-Deflection Characteristics of Superelastic Nickel-Titanium Wires

Load-Deflection Characteristics of Superelastic Nickel-Titanium Wires Original Article Load-Deflection Characteristics of Superelastic Nickel-Titanium Wires Theodosia N. Bartzela a ; Christiane Senn b ; Andrea Wichelhaus c ABSTRACT Objective: To determine the mechanical

More information

Anchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282

Anchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282 tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282 266 . innovative comprehensive efficient. Dentaurum Online Shop shop.dentaurum.com

More information

Plus Combines Traditional Twin Bracket Treatment With Self-Ligation Convenience

Plus Combines Traditional Twin Bracket Treatment With Self-Ligation Convenience Lotus Plus Combines Traditional Twin Bracket Treatment With Self-Ligation Convenience Designed by an Orthodontist The initial concept for the Lotus Plus Self-Ligating Bracket System started with a simple

More information

American Orthodontics americanortho.com (800) Damon, Natural, Ovoid, Roth. .016" x.022",.017" x.025",.018" x.025",.019" x.025",.021" x.

American Orthodontics americanortho.com (800) Damon, Natural, Ovoid, Roth. .016 x.022,.017 x.025,.018 x.025,.019 x.025,.021 x. Focus On WIRES 3M 3munitek.com (800) 423-4588 American Orthodontics americanortho.com (800) 558-7687 ClearBow clearbow.com (855) 538-4002 Dentaurum dentaurum.com (800) 523-3946 Wire name Unitek Beta III

More information

Thermal Nitanium. Archwires. Reduced Friction. Accelerated Results.

Thermal Nitanium. Archwires. Reduced Friction. Accelerated Results. Accel Low Friction Thermal Nitanium Archwires Reduced Friction. Accelerated Results. A Revolution In Sliding Mechanics Accel Low Friction Thermal Nitanium Archwires are the start of a new age in nickel

More information

THE NEW STANDARD IN CERAMIC BRACKET DESIGN

THE NEW STANDARD IN CERAMIC BRACKET DESIGN THE NEW STANDARD IN CERAMIC BRACKET DESIGN The model shown is wearing unretouched ClearVu Cosmetic Brackets featuring Personalized Color-Matching Technology. INNOVATIVE DESIGN For Doctors and Patients

More information

Mechanical and Surface Properties of Initial and Working Aesthetic Orthodontic Archwires

Mechanical and Surface Properties of Initial and Working Aesthetic Orthodontic Archwires ANNALS OF DENTISTRY University of Malaya ORIGINAL ARTICLE Mechanical and Surface Properties of Initial and Working Aesthetic Orthodontic Archwires Tang YC 1, Peh XL 1, Zakaria N N 2, Radzi Z 2* 1 Faculty

More information

The load/deflection characteristics of thermally activated orthodontic archwires

The load/deflection characteristics of thermally activated orthodontic archwires European Journal of Orthodontics 25 (2003) 417 421 2003 European Orthodontic Society The load/deflection characteristics of thermally activated orthodontic archwires Farnaz Parvizi and W. P. Rock School

More information

Delta Force. Bracket System. Putting you in the driver s seat for ultimate control

Delta Force. Bracket System. Putting you in the driver s seat for ultimate control Delta Force Bracket System Putting you in the driver s seat for ultimate control Variable Force Orthodontics The Delta Force Bracket System incorporates an advanced design that allows you to control the

More information

of the strain and of the temperature. Superelasticity in Orthodontics was first described for Japanese NiTi, which

of the strain and of the temperature. Superelasticity in Orthodontics was first described for Japanese NiTi, which ISSN: 0975-766X CODEN: IJPTFI Available Online through Research Article www.ijptonline.com SUPERELASTICITY OF NiTi Niha Naveed*, Dr. Sri Rengalakshmi Final Year BDS, Department of Orthodontics, Saveetha

More information

Measurements of the torque moment in various archwire bracket ligation combinations

Measurements of the torque moment in various archwire bracket ligation combinations European Journal of Orthodontics 34 (2012) 374 380 doi:10.1093/ejo/cjr022 Advance Access Publication 13 May 2011 The Author 2011. Published by Oxford University Press on behalf of the European Orthodontic

More information

GAC Archwire Collection

GAC Archwire Collection GAC Archwire Collection All the Metal That Matters Copper to Nickel and All Points In-Between Your choice in archwires is a critical decision in your quest for excellence. GAC has been recognized as a

More information

Is nickel titanium superior to multistranded stainless steel wire in aligning crowded lower anteriors? A comparative in-vivo study.

Is nickel titanium superior to multistranded stainless steel wire in aligning crowded lower anteriors? A comparative in-vivo study. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861. Volume 9, Issue 3 (Jul.- Aug. 2013), PP 47-51 Is nickel titanium superior to multistranded stainless steel

More information

Premium Heat Activated Arch Wire

Premium Heat Activated Arch Wire Premium Heat Activated Arch Wire TM Premium Heat Activated Arch Wire American Orthodontics is dedicated to continuous improvement, and delivers on this commitment by manufacturing our Tanzo Premium Heat

More information

Review of Orthodontic Archwires

Review of Orthodontic Archwires Chapter 2 Review of Orthodontic Archwires 2.1 Introduction The archwire, through mechanical interaction with the bracket slots, are designed to move teeth from malocclusion to a preferred dental occlusion.

More information

Simply Great Wire! Great prices.

Simply Great Wire! Great prices. 2017 CATALOG Simply Great Wire! Great prices. CONTENTS 2-4 NiTi Wires 5 Stainless Steel Wires 6-7 Archforms 8 Beta Titanium Molybdenum Wires 9 Wire Auxiliaries WWW.HIGHLANDMETALS.COM NiTi Wires SuperElastic

More information

Introducing the Clarity SL Self-Ligating Appliance System

Introducing the Clarity SL Self-Ligating Appliance System Introducing the Clarity SL Self-Ligating Appliance System Lunch and Learn Agenda Clarity SL Brackets Overview Consultation Benefits Bracket Positioning Benefits Bonding Benefits Leveling & Aligning Benefits

More information

ARCHWIRE. An extensive selection of high quality wire types and arch forms WIRE PRODUCTS. Wires. TruFlex Nickel Titanium Archwire. TruFlex.

ARCHWIRE. An extensive selection of high quality wire types and arch forms WIRE PRODUCTS. Wires. TruFlex Nickel Titanium Archwire. TruFlex. ARCHWIRE An extensive selection of high quality wire types and arch forms Archwire P.76-77, P.79, P.84-85 Thermal Archwire Copper Archwire TRIFECTA Thermal Archwire BetaForce Beta Titanium Archwire P.78-79

More information

Experience with Contemporary Tip-Edge plus Technique A Case Report.

Experience with Contemporary Tip-Edge plus Technique A Case Report. IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861. Volume 13, Issue 3 Ver. I. (Mar. 2014), PP 12-17 Experience with Contemporary Tip-Edge plus Technique A Case

More information

Victory Series Active Self-Ligating Brackets. Reliable. and. Effective

Victory Series Active Self-Ligating Brackets. Reliable. and. Effective Victory Series Active Self-Ligating Brackets Reliable and Effective Victory Series Active Self-Ligating Brackets Reliability Victory Series SL Brackets are widely accepted as an industry benchmark for

More information

The effect of Gable angle size and spring activation distance of 0.016x0.022 NiTi and TMA sectional T-loop towards force, moment y.

The effect of Gable angle size and spring activation distance of 0.016x0.022 NiTi and TMA sectional T-loop towards force, moment y. Padjadjaran Journal of Dentistry 2009;21(2):78-87. The effect of angle size and spring activation distance of 0.016x0.022 NiTi and TM sectional T-loop towards force, moment y values Norman Wachyudi, Tono

More information

History of NiTinol. Ni = Nickel Ti = Titanium N = Naval O = Ordnance L = Laboratory

History of NiTinol. Ni = Nickel Ti = Titanium N = Naval O = Ordnance L = Laboratory History of NiTinol Ni = Nickel Ti = Titanium N = Naval O = Ordnance L = Laboratory NiTinol was discovered in a laboratory of the U.S. Marines in 1962 (US-Naval Ordnance Laboratory). The U.S. Marines wanted

More information

Clinical Study Clinical Efficiency of Two Sequences of Orthodontic Wires to Correct Crowding of the Lower Anterior Teeth

Clinical Study Clinical Efficiency of Two Sequences of Orthodontic Wires to Correct Crowding of the Lower Anterior Teeth Hindawi Publishing Corporation e Scientific World Journal Volume 2015, Article ID 690280, 5 pages http://dx.doi.org/10.1155/2015/690280 Clinical Study Clinical Efficiency of Two Sequences of Orthodontic

More information

Plastic deformation occurs if the stress exceeds the

Plastic deformation occurs if the stress exceeds the ONLINE ONLY Effects of stress relaxation in beta-titanium orthodontic loops Sergei Godeiro Fernandes Rabelo Caldas, a Renato Parsekian Martins, b Rodrigo F. Viecilli, c Marılia Regalado Galv~ao, a and

More information

MATERIAL CHARACTERISTICS OF THE ORTHODONTIC ARCHWIRES

MATERIAL CHARACTERISTICS OF THE ORTHODONTIC ARCHWIRES DAAAM INTERNATIONAL SCIENTIFIC BOOK 20 pp. 30-308 CHAPTER 2 MATERIAL CHARACTERISTICS OF THE ORTHODONTIC ARCHWIRES SZUHANEK, C. Abstract Our aim was to investigate the mechanical properties of coated superelastic

More information

Archwires & Accessories

Archwires & Accessories Archwires & Accessories Orthodontic products-catalog 01 55 Archwires and Accessories Summary Archwire Shapes 58 Initialloy 59 BioEdge 60 BioActive 61 Reverse Curve 62 Beta Titanium 62 Stainless Steel Archwires

More information

Use of a Tip-Edge Stage-1 Wire to Enhance Vertical Control During Straight Wire Treatment: Two Case Reports

Use of a Tip-Edge Stage-1 Wire to Enhance Vertical Control During Straight Wire Treatment: Two Case Reports Case Report Use of a Tip-Edge Stage-1 Wire to Enhance Vertical Control During Straight Wire Treatment: Two Case Reports Helen Taylor, BDS, MScD, DOrth, MOrth, FDSRCS(Eng) a Abstract: Vertical control is

More information

The management of impacted

The management of impacted Using a rigid hook and spring auxiliary slid onto the archwire to direct eruption of impacted teeth BY S. JAY BOWMAN, DMD, MSD, AND ALDO CARANO, DR ODONT, MS, SPEC ORTHOD Figure 1: A 12-year-old female

More information

Introduction. Formerly known as Susan David

Introduction. Formerly known as Susan David European Journal of Orthodontics 20 (1998) 589 596 1998 European Orthodontic Society A comparative in vitro study of the frictional characteristics of two types of self-ligating brackets and two types

More information

The conservative treatment of Class I malocclusion with maxillary transverse deficiency and anterior teeth crowding

The conservative treatment of Class I malocclusion with maxillary transverse deficiency and anterior teeth crowding B B O C a s e R e p o r t The conservative treatment of Class I malocclusion with maxillary transverse deficiency and anterior teeth crowding Lincoln I. Nojima* Abstract This report describes the treatment

More information

A clinical comparison of three aligning archwires in terms of alignment efficiency: A prospective clinical trial

A clinical comparison of three aligning archwires in terms of alignment efficiency: A prospective clinical trial Original Article A clinical comparison of three aligning archwires in terms of alignment efficiency: A prospective clinical trial Reem Sh. Abdelrahman a ; Kazem S. Al-Nimri b ; Emad F. Al Maaitah c ABSTRACT

More information

Dental Materials Journal 2015; 34(3): Keisuke TOCHIGI, Souichiro ODA and Kazuhito ARAI INTRODUCTION

Dental Materials Journal 2015; 34(3): Keisuke TOCHIGI, Souichiro ODA and Kazuhito ARAI INTRODUCTION Dental Materials Journal 2015; 34(3): 388 393 Influences of archwire size and ligation method on the force magnitude delivered by nickel-titanium alloy archwires in a simulation of mandibular right lateral

More information

Evaluation of Torsional Strength of Ceramic Brackets Produced by Arch Wire Twisting Moment

Evaluation of Torsional Strength of Ceramic Brackets Produced by Arch Wire Twisting Moment Evaluation of Torsional Strength of Produced by Arch Wire Twisting Moment Raghavendra S. Vhanbatte, 1 Rashmi V. Uddanwadiker, 2 Pallavi Patil 3 1 Postgraduate student, Department of Mechanical Engineering,

More information

Controlled Space Closure with a Statically Determinate Retraction System

Controlled Space Closure with a Statically Determinate Retraction System Original Article Controlled Space Closure with a Statically Determinate Retraction System Kwangchul Choy, DDS, MS, PhD a ; Eung-Kwon Pae, DDS, MSc, PhD b ; Kyung-Ho Kim, DDS, MS, PhD c ; Young Chel Park,

More information

Torque efficiency of different archwires in and inch conventional brackets

Torque efficiency of different archwires in and inch conventional brackets Original Article Torque efficiency of different archwires in 0.018- and 0.022-inch conventional brackets Iosif Sifakakis a ; Nikolaos Pandis b ; Margarita Makou c ; Theodore Eliades d ; Christos Katsaros

More information

Valeri Petrov 1, Ivana Ilievska 2, Laura Andreeva 1, Valdek Mikli 3, Andrzej Zaleski 4, Angelina Stoyanova-Ivanova 2

Valeri Petrov 1, Ivana Ilievska 2, Laura Andreeva 1, Valdek Mikli 3, Andrzej Zaleski 4, Angelina Stoyanova-Ivanova 2 DOI: 10.18044/Medinform.201741.559 Studying the Effects of Autoclaving Process on Orthodontic Archwires Valeri Petrov 1, Ivana Ilievska 2, Laura Andreeva 1, Valdek Mikli 3, Andrzej Zaleski 4, Angelina

More information

We Give Back. Reduce Emergency Visits! ATTACHMENTS. No More Poking Archwires! Crimpable Mini Stops. Tooth Tone Crimpable Mini Stops

We Give Back. Reduce Emergency Visits! ATTACHMENTS. No More Poking Archwires! Crimpable Mini Stops. Tooth Tone Crimpable Mini Stops TTCHMENTS We Give Back Ortho Technology is a proud Founder Level Partner of the merican ssociation of Orthodontists Foundation. Ortho Technology is committed to making a positive difference in the future

More information

Aesthetic Brackets and Accessories

Aesthetic Brackets and Accessories Aesthetic Brackets and Accessories Our Strength is our Service Ortho-Care s version of the MBT prescription shown in this chapter is not claimed to be a duplication, and does not in any way imply endorsement

More information

THE EFFECT OF TOPICAL FLUORIDE AGENTS ON COATED NICKEL-TITANIUM ARCHWIRES. A THESIS IN Oral and Craniofacial Sciences

THE EFFECT OF TOPICAL FLUORIDE AGENTS ON COATED NICKEL-TITANIUM ARCHWIRES. A THESIS IN Oral and Craniofacial Sciences THE EFFECT OF TOPICAL FLUORIDE AGENTS ON COATED NICKEL-TITANIUM ARCHWIRES A THESIS IN Oral and Craniofacial Sciences Presented to the Faculty of the University of Missouri Kansas City in partial fulfillment

More information

Dental Research Journal

Dental Research Journal Dental Research Journal Original Article Effect of dry heat and steam sterilization on load-deflection characteristics of -titanium wires: An in vitro study Shiva Alavi 1, Neda Sinaee 1 1 Torabinejad Dental

More information

3D CONTROL HAS ARRIVED

3D CONTROL HAS ARRIVED TM 3D CONTROL HAS ARRIVED 1 Pitts 21 Self-Ligating System Pitts 21 Self-Ligating System Integrated Hooks An available option on the 3 s, 4 s and 5 s for your convenience at no extra charge. Smooth, Rounded

More information

The effect of buccal lingual slot dimension size on third-order torque response

The effect of buccal lingual slot dimension size on third-order torque response European Journal of Orthodontics, 2017, 209 214 doi:10.1093/ejo/cjw043 Advance Access publication 3 June 2016 Original Article The effect of buccal lingual slot dimension size on third-order torque response

More information

Combined aging effects of strain and thermocycling on unload deflection modes of nickel-titanium closed-coil springs: An in-vitro comparative study

Combined aging effects of strain and thermocycling on unload deflection modes of nickel-titanium closed-coil springs: An in-vitro comparative study ORIGINAL ARTICLE Combined aging effects of strain and thermocycling on unload deflection modes of nickel-titanium closed-coil springs: An in-vitro comparative study Gabriele Vidoni, a Giuseppe Perinetti,

More information

A randomized clinical trial to compare three methods of orthodontic space closure

A randomized clinical trial to compare three methods of orthodontic space closure Journal of Orthodontics, Vol. 29, 2002, 31 36 SCIENTIFIC SECTION A randomized clinical trial to compare three methods of orthodontic space closure V. Dixon, M. J. F. Read, K. D. O Brien, H. V. Worthington

More information

The Effect of Water Storage on Bending Properties of Esthetic, Fiber-Reinforced Composite Orthodontic Wires

The Effect of Water Storage on Bending Properties of Esthetic, Fiber-Reinforced Composite Orthodontic Wires Marquette University e-publications@marquette Master's Theses (2009 -) Dissertations, Theses, and Professional Projects The Effect of Water Storage on Bending Properties of Esthetic, Fiber-Reinforced Composite

More information

Copper, Aluminum and Nickel: A New Monocrystalline Orthodontic Alloy

Copper, Aluminum and Nickel: A New Monocrystalline Orthodontic Alloy Loma Linda University TheScholarsRepository@LLU: Digital Archive of Research, Scholarship & Creative Works Loma Linda University Electronic Theses, Dissertations & Projects 9-2014 Copper, Aluminum and

More information

A New Low-Friction Ligation System

A New Low-Friction Ligation System 2005 JCO, Inc. May not be distributed without permission. www.jco-online.com A New Low-Friction Ligation System ARTURO FORTINI, MD, DDS MASSIMO LUPOLI, MD, DDS VITTORIO CACCIAFESTA, DDS, MS Many factors

More information

Canine Extrusion Technique with SmartClip Self-Ligating Brackets

Canine Extrusion Technique with SmartClip Self-Ligating Brackets Canine Extrusion Technique with SmartClip Self-Ligating Brackets Dr. Luis Huanca Ghislanzoni Dr. Luis Huanca received his DDS in 2006 and the MS and Specialist in Orthodontics in 2009 from the University

More information

Frictional Forces of a Fixed, Esthetic Orthodontic Appliance System

Frictional Forces of a Fixed, Esthetic Orthodontic Appliance System UNLV Theses, Dissertations, Professional Papers, and Capstones 12-1-2012 Frictional Forces of a Fixed, Esthetic Orthodontic Appliance System Brady Michael Nance University of Nevada, Las Vegas, brady.nance@sdm.unlv.edu

More information

The influence of distal-end heat treatment on deflection of nickel-titanium archwire

The influence of distal-end heat treatment on deflection of nickel-titanium archwire The influence of distal-end heat treatment on deflection of nickel-titanium archwire Marcelo Faria da Silva 1, Célia Regina Maia Pinzan-Vercelino 2, Júlio de Araújo Gurgel 2 DOI: http://dx.doi.org/10.1590/2177-6709.21.1.083-088.oar

More information

How does temperature influence the properties of rectangular nickel titanium wires?

How does temperature influence the properties of rectangular nickel titanium wires? European Journal of Orthodontics 28 (2006) 282 291 doi:10.1093/ejo/cji079 Advance Access publication 30 September 2005 The Author 2005. Published by Oxford University Press on behalf of the European Orthodontics

More information

Comparison of deflection forces of esthetic archwires combined with ceramic brackets*

Comparison of deflection forces of esthetic archwires combined with ceramic brackets* Original Article http://dx.doi.org/10.1590/1678-7757-2017-0220 Comparison of deflection forces of esthetic archwires combined with ceramic brackets* Abstract Murilo MATIAS 1 Marcos Roberto de FREITAS 1

More information

Even though the acid-etching technique is useful

Even though the acid-etching technique is useful SHORT COMMUNICATION Bond failure rates with a self-etching primer: A randomized controlled trial Julio Pedra e Cal-Neto, a Cátia Abdo Quintão, b Marco Antônio de Oliveira Almeida, c and José Augusto Mendes

More information

Advantages. Fantastic. systems. Together with Unitek Lateral Development Archwires, this system puts you in control to

Advantages. Fantastic. systems. Together with Unitek Lateral Development Archwires, this system puts you in control to 3M Self-Ligating Appliances Lateral Development System Treatment Advantages Fantastic Finishes For orthodontic professionals who choose lateral development as a desired treatment outcome, 3M now offers

More information

Advantages. Fantastic. Treatment. Finishes. 3M Self-Ligating Appliances Lateral Development System. Unitek Lateral Development Archwires

Advantages. Fantastic. Treatment. Finishes. 3M Self-Ligating Appliances Lateral Development System. Unitek Lateral Development Archwires 3M Self-Ligating Appliances Lateral Development System Treatment Advantages Fantastic Finishes Adhesive Coated Appliance System Adhesive Coated Appliance System Unitek Lateral Development Archwires For

More information

tomas - Anchorage System

tomas - Anchorage System 302-000-00 1 Set 302-200-00 1 kit tomas -set (starter-set) Skeletal anchorage for orthodontic tooth movement The tomas -set contains all components of the system and is recommended to start out in this

More information

American Orthodontics (800) NiTi, superelastic NiTi, thermal NiTi x.022,.017 x.025,.018 x.025,.019 x.025

American Orthodontics (800) NiTi, superelastic NiTi, thermal NiTi x.022,.017 x.025,.018 x.025,.019 x.025 Wire Name 3M Unitek (800) 423-4588 3MUnitek.com Unitek Nitinol Heat-Activated Archwire OrthoForm II American Orthodontics (800) 558-7687 americanortho.com Dentaurum (800) 523-3946 dentaurum.com DENTSPLY

More information

A Collection of High Quality Orthodontic Instruments

A Collection of High Quality Orthodontic Instruments A Collection of High Quality Orthodontic Instruments User friendly ergonomic design Tenvis instruments starts with a great design, the finest materials and a commitment to quality. Meticulously handcrafted

More information

MemRx Orthodontic Appliances

MemRx Orthodontic Appliances MemRx Orthodontic Appliances Uses and Instructions The MemRx Fundamentals As the need for faster, more efficient treatment of non-compliant patients increases, orthodontic!technology and materials has

More information

Synergistic effect of wire bending and salivary ph on surface properties and mechanical properties of orthodontic stainless steel archwires

Synergistic effect of wire bending and salivary ph on surface properties and mechanical properties of orthodontic stainless steel archwires Hobbelink et al. Progress in Orthodontics (2015) 16:37 DOI 10.1186/s40510-015-0109-6 RESEARCH Open Access Synergistic effect of wire bending and salivary ph on surface properties and mechanical properties

More information

Orthodontic bracket slot dimensions as measured from entire bracket series

Orthodontic bracket slot dimensions as measured from entire bracket series Original Article Orthodontic bracket slot dimensions as measured from entire bracket series Paul Brown a ; Warren Wagner b ; Hyden Choi c ABSTRACT Objective: To measure the slot dimensions of an entire

More information

Integrative Orthodontics with the Ribbon Arch By Larry W. White, D.D.S., M.S.D.

Integrative Orthodontics with the Ribbon Arch By Larry W. White, D.D.S., M.S.D. Integrative Orthodontics with the Ribbon Arch By Larry W. White, D.D.S., M.S.D. Abstract The ribbon arch previously had great popularity and utility early in the 20 th century, but lost its appeal as edgewise

More information

Friction between different wire bracket combinations in vitro evaluation

Friction between different wire bracket combinations in vitro evaluation www.scielo.br/jaos Friction between different wire bracket combinations in vitro evaluation Tatiana Kelly da Silva FIDALGO 1, Matheus Melo PITHON 2, José Vinicius Bolognesi MACIEL 2, Ana Maria BOLOGNESE

More information

TOL

TOL 2017 TOL 877.223.8114 www.tinglab.com Dear Valued Customer, Ting Orthodontic Lab & Supply is proud to celebrate 30 years of providing outstanding service to many of the finest orthodontists and dentists

More information

INFLUENCE OF ARTIFICIAL SALIVA ON NiTi ORTHODONTIC WIRES: A STUDY ON THE SURFACE CHARACTERIZATION

INFLUENCE OF ARTIFICIAL SALIVA ON NiTi ORTHODONTIC WIRES: A STUDY ON THE SURFACE CHARACTERIZATION Materials Science, Vol. 47, No. 6, May, 2012 (Ukrainian Original Vol. 47, No. 6, November December, 2011) INFLUENCE OF ARTIFICIAL SALIVA ON NiTi ORTHODONTIC WIRES: A STUDY ON THE SURFACE CHARACTERIZATION

More information

Mechanical Properties of Different Aesthetic Archwires

Mechanical Properties of Different Aesthetic Archwires Original Article Mechanical Properties of Different Aesthetic Archwires Mehmet Akın, DDS, PhD; 1 Zehra İleri, DDS, PhD; 1 Sertaç Aksakallı, DDS, PhD; 2, * and Faruk Ayhan Basxçiftçi, DDS, PhD 3 ABSTRACT

More information

INDICATIONS. Fixed Appliances are indicated when precise tooth movements are required

INDICATIONS. Fixed Appliances are indicated when precise tooth movements are required DEFINITION Fixed Appliances are devices or equipments that are attached to the teeth, cannot be removed by the patient and are capable of causing tooth movement. INDICATIONS Fixed Appliances are indicated

More information

Objectives: The shape memory resulting from the superelasticity and thermoelastic effect

Objectives: The shape memory resulting from the superelasticity and thermoelastic effect www.scielo.br/jaos Transition temperature range of thermally activated nickel-titanium archwires 1 1 1 FREITAS 1 2 1- Department of Orthodontics. Ingá Faculty, Maringá, PR, Brazil. 2- Department of Biomedical

More information

Focus on Minor Tooth Movement Systems

Focus on Minor Tooth Movement Systems Accutech Orthodontic Lab Inc (800) 734-7855 accutechortho.com Allesee Orthodontic Appliances (AOA Labs) (800) 262-5221 aoalab.com Appliance Therapy Group (800) 423-3270 ApplianceTherapy.com ClearCorrect

More information

(12) Patent Application Publication (10) Pub. No.: US 2005/ A1

(12) Patent Application Publication (10) Pub. No.: US 2005/ A1 (19) United States US 2005O130094A1 (12) Patent Application Publication (10) Pub. No.: US 2005/0130094A1 Graham (43) Pub. Date: Jun. 16, 2005 (54) ORTHODONTIC ACCESSORY ARCH BAR (52) U.S. Cl.... 433/20

More information

Mechanical Properties of Graded Thermodynamic Nickel Titanium Archwires in Bending and Torsion

Mechanical Properties of Graded Thermodynamic Nickel Titanium Archwires in Bending and Torsion Mechanical Properties of Graded Thermodynamic Nickel Titanium Archwires in Bending and Torsion by Ouliana Oguienko A thesis submitted in conformity with the requirements for the degree of Master of Science

More information

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal

Acknowledgments Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal Preface p. v Acknowledgments p. vii Introduction p. 1 Objectives p. 1 Goals p. 2 History of Dental Materials p. 3 The Oral Environment p. 4 Characteristics of the Ideal Dental Material p. 5 Quality Assurance

More information

The Ultimate in Crystal Clear Aesthetics

The Ultimate in Crystal Clear Aesthetics The Ultimate in Crystal Clear Aesthetics SEM x500 SEM x30 SEM x25 SEM x30 Patient Aesthetics The macro photograph shows the clarity of the flawless PURE brackets. Made from pure monocrystalline sapphire

More information

HYCON DEVICE: A PRECISE AND CONTROLLED METHOD OF SPACE CLOSURE A CASE REPORT

HYCON DEVICE: A PRECISE AND CONTROLLED METHOD OF SPACE CLOSURE A CASE REPORT HYCON DEVICE: A PRECISE AND CONTROLLED METHOD OF SPACE CLOSURE A CASE REPORT Authors: Dr Arun Kumar G a Master of Dental Surgery(Orthodontics) Associate Professor, Department of Orthodontics & Dentofacial

More information

GREAT LAKES BRACKETS. Treat with Quality. Treat with Confidence.

GREAT LAKES BRACKETS. Treat with Quality. Treat with Confidence. GREAT LAKES BRACKETS Treat with Quality. Treat with Confidence. BRACKET SYSTEMS DESIGNED BY ORTHODONTISTS, FOR ORTHODONTISTS, GREAT LAKES BRACKETS DELIVER. EVERY SINGLE BRACKET IS HAND INSPECTED AND ENGINEERED

More information

PhD in Materials for Health, Environment and Energy, University of Rome Tor Vergata, Rome, Italy

PhD in Materials for Health, Environment and Energy, University of Rome Tor Vergata, Rome, Italy Aesthetic orthodontic Archwires: the state of Art Introduction M. TOTINO 1, A. RICCIO 1, M. LEO 1, L. ARCURI 1, L. CERRONI 2, G. PASQUANTONIO 2, R. CONDÒ 2 1 PhD in Materials for Health, Environment and

More information

Characterizing constraining forces in the alignment phase of orthodontic treatment

Characterizing constraining forces in the alignment phase of orthodontic treatment Original Article Characterizing constraining forces in the alignment phase of orthodontic treatment Christopher G. Gibson a ; Feng-Chang Lin b ; Ceib Phillips c ; Alex Edelman d ; Ching-Chang Ko e ABSTRACT

More information

SELF LIGATING BRACKETS. 1. Commercial name: EasyClip EasyClip+ Lotus Self-ligating single buccal tubes

SELF LIGATING BRACKETS. 1. Commercial name: EasyClip EasyClip+ Lotus Self-ligating single buccal tubes PAGE 1 of 6 1. Commercial name: EasyClip EasyClip+ Lotus Self-ligating single buccal tubes 2. Manufacturer: Aditek do Brasil Ltda. Address: Cesário Mota, 14 ZIP: 14140-000 - Cravinhos SP - Brazil Phone:

More information

Mechanical Behavior of Silver Alloys Used as Cast Post and Core in Maxillary Incisors

Mechanical Behavior of Silver Alloys Used as Cast Post and Core in Maxillary Incisors Vol. Materials 7, No. Research, 2, 2004 Vol. 7, No. 2, Mechanical 255-262, 2004. Behavior of Silver Alloys Used as Cast Post and Core in Maxillary Incisors 2004 255 Mechanical Behavior of Silver Alloys

More information

Orthodontic Product Catalog

Orthodontic Product Catalog Orthodontic Product Catalog ceramic brackets 1 self-ligating appliances 2 metal brackets 3 3M Vision 3M Technology Advancing Every Company 3M Products Enhancing Every Home 3M Innovation Improving Every

More information

Class I. Clear Fixed Appliance vs. Aligner Treatment for Arch Development. Clinician: Dr. Stuart Frost, Phoenix, AZ Patient: A.M.

Class I. Clear Fixed Appliance vs. Aligner Treatment for Arch Development. Clinician: Dr. Stuart Frost, Phoenix, AZ Patient: A.M. Clear Fixed Appliance vs. Aligner Treatment for Arch Development Class I End-to-End Molar Clinician: Dr. Stuart Frost, Phoenix, AZ Patient: A.M. Pretreatment Diagnosis Class I (end-to-end molar on right),

More information

A comparative assessment of torque generated by lingual and conventional brackets

A comparative assessment of torque generated by lingual and conventional brackets European Journal of Orthodontics 35 1 of (2013) 6 375 380 doi:10.1093/ejo/cjs029 Advance Access publication 9 May 2012 The Author 2012. Published by Oxford University Press on behalf of the European Orthodontic

More information

Wire is the key player in the movement of teeth, so choosing the right wire is critical for successful treatment. ODP offers a full range of wire

Wire is the key player in the movement of teeth, so choosing the right wire is critical for successful treatment. ODP offers a full range of wire w i r e p r o d u c t s Wire is the key player in the movement of teeth, so choosing the right wire is critical for successful treatment. ODP offers a full range of wire types, arch forms, sizes, and force

More information

A Comparison of Frictional Resistance between Active and Passive Self-ligating Brackets with Conventional Bracket Systems

A Comparison of Frictional Resistance between Active and Passive Self-ligating Brackets with Conventional Bracket Systems 10.5005/jp-journals-10015-1102 H ORIGINAL Jyothikiran et RESEARCH al A Comparison of Frictional Resistance between Active and Passive Self-ligating Brackets with Conventional Bracket Systems 1 H Jyothikiran,

More information

Efficient Bonding Protocol for the Insignia Custom Bracket System

Efficient Bonding Protocol for the Insignia Custom Bracket System Efficient Bonding Protocol for the Insignia Custom Bracket System Abstract The Insignia appliance is reverse-engineered from a digital set-up of the prescribed dental alignment. Each bracket configuration,

More information

Effects of CO 2 laser debonding of a ceramic bracket on the mechanical properties of enamel

Effects of CO 2 laser debonding of a ceramic bracket on the mechanical properties of enamel Original Article Effects of CO 2 laser debonding of a ceramic bracket on the mechanical properties of enamel Masahiro Iijima a ; Yoshitaka Yasuda b ; Takeshi Muguruma c ; Itaru Mizoguchi d ABSTRACT Objective:

More information

SnapLink Re-Convertible Tube

SnapLink Re-Convertible Tube SnapLink Re-Convertible Tube Background Buccal tubes are attached to the upper and lower molars to anchor the distal ends of archwires, or to attach an auxiliary wire, headgear or lip bumper, or as an

More information

Effect of Sodium Fluoride Mouthwash on the Frictional Resistance of Orthodontic Wires

Effect of Sodium Fluoride Mouthwash on the Frictional Resistance of Orthodontic Wires Original Article Effect of Sodium Fluoride Mouthwash on the Frictional Resistance of Orthodontic Wires Allahyar Geramy 1, Tabassom Hooshmand 2, Tahura Etezadi 3 1 Professor, Dental Research Center, Dentistry

More information

RESEARCH ARTICLE /jp-journals

RESEARCH ARTICLE /jp-journals 10.5005/jp-journals-10021-1131 RESEARCH ARTICLE Parikshit Rajkumar Rao et al Evaluation and Comparison of Biomechanical Properties of Snail Loop with that of Opus Loop and Teardrop Loop for en masse Retraction

More information

Effects of a diamond-like carbon coating on the frictional properties of orthodontic wires

Effects of a diamond-like carbon coating on the frictional properties of orthodontic wires Original Article Effects of a diamond-like carbon coating on the frictional properties of orthodontic wires Takeshi Muguruma a ; Masahiro Iijima b ; William A. Brantley c ; Itaru Mizoguchi d ABSTRACT Objective:

More information

Comparison of the superelasticity of different nickel titanium orthodontic archwires and the loss of their properties by heat treatment

Comparison of the superelasticity of different nickel titanium orthodontic archwires and the loss of their properties by heat treatment J Mater Sci: Mater Med (2016) 27:158 DOI 10.1007/s10856-016-5767-5 BIOMATERIALS SYNTHESIS AND CHARACTERIZATION Original Research Comparison of the superelasticity of different nickel titanium orthodontic

More information

An in vitro investigation of the influence of self-ligating brackets, low friction ligatures, and archwire on frictional resistance

An in vitro investigation of the influence of self-ligating brackets, low friction ligatures, and archwire on frictional resistance European Journal of Orthodontics 29 (2007) 390 397 doi:10.1093/ejo/cjm007 The Author 2007. Published by Oxford University Press on behalf of the European Orthodontic Society. All rights reserved. For permissions,

More information

The effect of surface treatment and clinical use on friction in NiTi orthodontic wires

The effect of surface treatment and clinical use on friction in NiTi orthodontic wires Dental Materials (2005) 21, 938 945 www.intl.elsevierhealth.com/journals/dema The effect of surface treatment and clinical use on friction in NiTi orthodontic wires Andrea Wichelhaus a, *, Marc Geserick

More information