Quick Reference Guide. on Turbodyne SC
|
|
- Oliver Short
- 5 years ago
- Views:
Transcription
1 RF Turbodyne RF Quantitative turbidimetric immunoassay for determination of Rheumatoid Factors Turbodyne RF is used for the detection of Rheumatoid Arthritis (RA), Differential diagnosis of RA from Rheumatic fever and other rheumatic disorders. Turbodyne RF Kit components: Turbodyne RF Activation Buffer (R1) Turbodyne RF Latex Reagent (R2) Turbodyne RF Smart Card suitably modified Fc fraction of human IgG Smart card with RF Calibration curve calibrated with a standard traceable to International Reference Preparation of Rheumatoid Arthritis serum Measuring range: IU/ml Specificity: Suitably modified Fc fraction of human IgG specific for IgM rheumatoid factors Latex based Fc fraction of aggregated human IgG reagent (R2) Calibration traceable to WH International reference preparation of Rheumatoid arthritis serum High Specificity to heterospecific IgM - RF Facilitates complete utilization of reagent within stability period Turbodyne RF control I N N V A T I V E E X C E L L E N C E
2 CRP Turbodyne CRP Quantitative turbidimetric immunoassay for determination of C-Reactive Protein Turbodyne CRP is used for the detection of inflammatory conditions, measuring the severity of conditions, differential diagnosis of bacterial and viral infections, also used for monitoring response to therapy. Turbodyne CRP Kit components: Turbodyne CRP Activation Buffer (R1) Turbodyne CRP Latex Reagent (R2) Turbodyne CRP Smart Card anti-crp antibody. Smart card Calibration curve calibrated with a standard traceable to W.H.. International Reference Standard (85/506) for Human C-reactive protein Measuring range: mg/dl Specificity: Anti-CRP antibodies of IgG class specific to CRP Ready to use uniform suspension of polystyrene latex particles coated with anti-crp antibody (R2) High Specificity to C - reactive protein Calibrator traceable to International reference standard (85/506) for C - reactive protein Facilitates complete utilization of reagent within stability period Turbodyne CRP control I N N V A T I V E E X C E L L E N C E
3 AS Turbodyne AS Quantitative turbidimetric immunoassay for determination of Antistreptolysin Turbodyne AS is used for detection of A streptococcal infection such as sore throat, rheumatic fever and rheumatic heart disease. Turbodyne AS Kit components: Turbodyne AS Activation Buffer (R1) Turbodyne AS Latex Reagent (R2) Turbodyne AS Smart Card stabilized Streptolysin '' Smart card Calibration curve that is traceable to the International standard for Anti-Streptolysin (97/662) Measuring range: IU/ml Specificity: Purified Streptolysin specific for Anti-Streptolysin antibodies Latex conjugated with Stabilized Streptolysin '' reagent (R2) Calibrator traceable to International reference standard for Antistreptolysin '' (97/662) High Specificity to Antistreptolysin '' Turbodyne AS control I N N V A T I V E E X C E L L E N C E
4 MA Turbodyne MA Quantitative turbidimetric immunoassay for determination of Microalbuminaria Turbodyne MA is used for the detection of Microalbuminuria. Turbodyne MA Kit components: Turbodyne MA Activation Buffer (R1) Turbodyne MA Anti-Human Albumin Reagent (R2) Turbodyne MA Smart Card Ready to use solution of anti-human albumin antibody Smart card with MA master calibration curve calibrated with a standard traceable to the IFCC reference material CRM 470 Measuring range: mg/l Specificity: Anti-human albumin antibody specific to human albumin Anti-human albumin reagent (R2) Calibrator traceable to IFCC reference preparation 'CRM 470' High Specificity to human albumin Turbodyne MA control I N N V A T I V E E X C E L L E N C E
5 IgE Turbodyne IgE Quantitative turbidimetric immunoassay for the estimation of Immunoglobulin E (IgE) in human serum Turbodyne IgE is used to determine if an allergic reaction is IgE mediated or non IgE mediated. IgE levels can increase in atopic diseases, neoplasm, immunodeficiencies and parasitic infections. Turbodyne IgE Kit components: Turbodyne IgE Activation Buffer (R1) Turbodyne IgE Latex Reagent (R2) Turbodyne IgE Smart Card Ready to use polystyrene latex particles coated with antihuman IgE Smart Card with IgE master calibration curve calibrated with a standard traceable to the Standard International Preparation of IgE 75/502 from WH Measuring range: IU/ml Specificity: Anti-human IgE antibody specific to IgE in human serum Ready to use polystyrene latex particles coated with antihuman IgE (R2) Calibrator traceable to International reference preparation (WH) of IgE 75/502 High Specificity to Immunoglobulin class IgE Turbodyne IgE control I N N V A T I V E E X C E L L E N C E
6 Cystatin C Turbodyne Cystatin C Quantitative turbidimetric immunoassay for Cystatin C Turbodyne Cystatin C is used for detection of Cystatin C. Serum Cystatin C is proposed to be an ideal endogenous marker for glomerular filtration rate (GFR) especially in patients with moderate to severe impaired renal impairment. Turbodyne Cystatin C Kit components: Turbodyne Cystatin C Activation Buffer (R1) Turbodyne Cystatin C Latex Reagent (R2) Turbodyne Cystatin C Smart Card purified immunoglobulin fraction that is directed against Cystatin C Smart card with Cystatin C calibration curve with a standard that has been validated against IFCC standard Measuring range: mg/l Specificity: Purified immunoglobulin fraction specific to Cystatin C Use of latex coated with purified immunoglobulin fraction directed against Cystatin C (R2) High Specificity Turbodyne Cystatin C control I N N V A T I V E E X C E L L E N C E
7 HbA1c Turbodyne HbA1c Turbidimetric immunoassay for quantitative determination of HbA1c in human blood Turbodyne HbA1c is used for long term assessment of glycemic state of patients with diabetes and goals for therapy are set at specific HbA1c values. Turbodyne HbA1c is a turbidimetric immunoassay for direct determination of HbA1c in human blood without the need to estimate total hemoglobin. Turbodyne HbA1c Kit components: Turbodyne HbA1c Latex Reagent (R1) Turbodyne HbA1c Antibody Reagent (R2) Turbodyne HbA1c Hemolysing Reagent Turbodyne HbA1c Smart Card Ready to use uniform suspension of latex particles Ready to use solution of mouse anti-human HBA1c and goat anti mouse IgG antibody Ready to use solution Smart card with HbA1c calibration curve calibrated with a standards traceable to a NGSP National Glycohaemoglobulin Standardisation Program) certified method that has documented traceability to the Diabetes control and Complications Trial (DCCT) reference method Measuring range: HbA1c in the concentration 5-15% Direct results in % HbA1c Uses Monoclonal mouse antihuman HbA1c antibody Standardized using calibrators traceable to NGSP/DCCT Directly measures % HbA1c without measuring total hemoglobin Accurate results, reacts only with HbA1c Results aligned to Reference Method Turbodyne HbA1c control I N N V A T I V E E X C E L L E N C E
HumaTex CRP. Design Verification. Contents
Design Verification HumaTex CRP Contents 1 Function... 2 2 Reproducibility... 2 3 Sensitivity and dynamic range... 2 Preparation of serum control panel... 2 Sensitivity test results... 2 Prozone check...
More informationExcellence and confidence
Thermo Scientific System Reagents Fully supported and guaranteed, CE marked system solutions Streamlined supply and support Maximum stability and reduced waste Standardised performance in External Quality
More informationAnswering your daily challenges in ASO detection. Anti-Streptolysin O. rapid test. rheumajet ASO I NFECTIOU S DI SEASES.
Answering your daily challenges in ASO detection Anti-Streptolysin O rheumajet ASO I NFECTIOU S DI SEASES I N F E C T I O U S D I S E A S E S Anti-streptolysin O Anti-Streptolysin O (ASO) antibodies appear
More informationBulk Assay Supply Catalog
Bulk Assay Supply Catalog Living Immunoassay Excellence Biokit is a privately owned biotechnological company that is part of Werfen. It was founded in 1973 and is aimed at the research, development, manufacture
More informationThermo Scientific System Reagents Excellence in Clinical Chemistry
Thermo Scientific System Reagents Excellence in Clinical Chemistry Part of Thermo Fisher Scientific Covering over 150 CE marked products, Thermo Scientific system reagents are specifically developed and
More informationPrimary Sample Manual Infectious Serology Issue No Effective Date: 20/09/17 Page 1 of 15 EUROFINS BIOMNIS
Issue No. 2.02 Effective Date: 20/09/17 Page 1 of 15 Written / Revised By: Dr. Mike Louw, Medical Director Date: Reviewed By: Date: Dr. Sinead Kelly, Infectious Serology Consultant Authorised By: Jean-Sébastien
More informationOptimized for best performance in clinical chemistry testing
Optimized for best performance in clinical chemistry testing System Reagents for Indiko and Konelab clinical and specialty chemistry analyzers Complete system solutions Thermo Scientific system reagents
More informationTurbidos. Design Verification. Contents
Design Verification Turbidos Contents 1 adjustment... 2 2 Target value determination... 2 3 Stability... 2 3.1 Accelerated stress data... 2 3.2 Open vial stability... 3 3.3 Real Time Stability... 4 4 Result
More informationSmart Diagnostics for Point-of-Care!
Smart Diagnostics for Point-of-Care! The one special multi-parameter Point-of-Care (POC) instrument that covers the constantly expanding range of applications with the highest precision. Designed for HbA1c
More informationLatex Agglutination Kits
Latex Agglutination Kits 062916tr Headquarters A Culture of Service 1430 West McCoy Lane Santa Maria, CA 93455 800.266.2222 : phone Sales@HardyDiagnostics.com www.hardydiagnostics.com Distribution Centers
More informationLaboratory Procedure Handout RHEUMATOID FACTORS
KING ABDULAZIA UNIVERSITY FACULTY OF APPLIED MEDICAL SCIENCES DEPARTEMENT OF LABORATORY MEDICAL TECHNOLOGY Laboratory Procedure Handout RHEUMATOID FACTORS RF Latex agglutination for detection of RF INTRODUCTION
More informationHexagon PSA. Design Verification. Contents
Design Verification Hexagon PSA Contents 1. Function...2 2. Sensitivity, Dynamic Range and Traceability...2 Description of Control Materials...2 Analytical Sensitivity...2 3. Clinical Evaluation...3 Evaluation
More informationMADE IN KOREA. Advanced POCT. Automated 6 Channels. Automated Single Channel. POCT to Desktop. Our technology covers it all!
MADE IN KOREA Advanced POCT Automated 6 Channels Automated Single Channel POCT to Desktop Our technology covers it all! Compact Desktop Immuno- Automated desktop 6 channels 2 bays Bay random access Run
More informationEvaluation Report. Eurolyser HbA1c Test Kit on Smart and Cube Analyser
Evaluation Report Eurolyser HbA1c Test Kit on Smart and Cube Analyser Locations Location 1: Klinisk kemi University Hospital MAS Malmö Operator: Dr. Benny Larsson Date: June/July 2007 Location 2: Eurolyser
More informationVITROS MicroTip Assay Summary
AAT α-antitrypsin AMPH Amphetamine ApoA1 Apolipoprotein A1 ApoB Apolipoprotein B1 ASO Antistreptolysin O BARB Barbiturates BENZ Benzodiazapines C3 Complement C3 6.7 99 AAT/HPT PV FS Pack 2 (Saline dilution)
More informationAFIAS 6 (Automatic Fluorescence Immuno-Assay)
AFIAS 6 (Automatic Fluorescence Immuno-Assay) Each SMART kit contains ten (10) cartridges, one (1) ID Chip, and one (1) instruction for use AFIAS 6 (Automatic Fluorescence Immuno-Assay) is a next-generation,
More informationEffective Date: 09/08 Supersedes Revision/Date: Original Revision: 09/08 Date Adopted:
Institution: Procedure No.: Page 1 of 5 Procedure: ASI RF DIRECT SLIDE TEST Doc#: 6004-700DC CLSI Effective Date: 09/08 Supersedes Revision/Date: Original Revision: 09/08 Supersedes Procedure # Prepared
More informationThe Adiponectin Turbidimetric Immunoassay Reagent Kit
The Adiponectin Turbidimetric Immunoassay Reagent Kit Catalogue number: 51010 For the quantitative determination of Adiponectin in human serum and plasma This package insert must be read in its entirety
More informationThermo Scientific Konelab System Reagents For convenient and reliable analysis
Thermo Scientific Konelab System Reagents For convenient and reliable analysis Part of Thermo Fisher Scientific Thermo Scientific Konelab system reagents ensure the high quality analysis results Easy-to-use
More informationDIRECT ENZYMATIC HbA1c ASSAY
DIRECT ENZYMATIC HbA1c ASSAY ACCURATE AND SIMPLE DIAZYME INNOVATIONS IN CLINICAL DIAGNOSTICS About Diazyme Diazyme Laboratories is a Division of General Atomics located in Poway, California. Diazyme uses
More informationInnovation in Diagnostics. ToRCH. A complete line of kits for an accurate diagnosis INFECTIOUS ID DISEASES
Innovation in Diagnostics ToRCH A complete line of kits for an accurate diagnosis INFECTIOUS ID DISEASES EN TOXOPLASMOSIS Toxoplasmosis is a parasitic disease caused by with the obligate intracellular
More informationREAD HIGHLIGHTED CHANGES
BIO-FLASH Toxo IgM 3000-8554 50 tests The BIO-FLASH Toxo IgM is a fully automated chemiluminescent two-step immunoassay for qualitative measurement of IgM antibodies to Toxoplasma gondii in human serum
More informationEvaluation Report: Eurolyser CRP test (ST0100 and ST0102) on. CUBE analyser (CA0100)
Evaluation Report: Eurolyser CRP test (ST0100 and ST0102) on CUBE analyser (CA0100) Location Location: Eurolyser Diagnostica GmbH Operators: Simone Wieser; Franz Helminger; Michael Gruber Date: July-November
More informationLaboratory and Measurement Issues. Greg Miller, PhD Virginia Commonwealth University Richmond, VA
Laboratory and Measurement Issues Greg Miller, PhD Virginia Commonwealth University Richmond, VA Outline Serum/plasma creatinine Serum/plasma cystatin C Urine albumin Urine protein Creatinine standardization
More informationDesign Verification. Form:
Design Verification SYPHILIS TPHA liquid CONTENTS 1 Function... 2 2 Sensitivity... 2 Preparation of Serum Control Panel... 2 Kit Controls Positive and Negative... 3 3 Traceability... 3 4 Specificity and
More informationCystatin C (serum, plasma, urine)
Cystatin C (serum, plasma, urine) 1 Name and description of analyte 1.1 Name of analyte Cystatin C (serum, plasma and urine) 1.2 Alternative names Cystatin 3, post-gamma-globulin, neuroendocrine basic
More informationUrine/CSF Albumin Reagent. Urine/CSF Albumin Calibrator
December 2014 PRODUCT ANNOUNCEMENT AU Clinical Chemistry Systems AU400/400 e, AU480, AU640/640 e, AU680, AU2700, AU5400, and AU5800 Product Urine/CSF Albumin Reagent Urine/CSF Albumin Reagent Urine/CSF
More informationRheumatoid Factor Plus Test System
Rheumatoid Factor Plus Test System A Microparticle-Based Immunoassay for Rheumatoid Factor (RF) IgM Antibodies Product Number: A91101M INTENDED USE The Zeus Scientific, Inc. AtheNA Multi-Lyte RF Plus Test
More informationSee external label 2 C-8 C = C-REACTIVE PROTEIN (CRP) LATEX SLIDE TEST
CORTEZ DIAGNOSTICS, INC. 21250 Califa Street, Suite 102 and 116, Woodland Hills, CA 91367 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com
More informationBiochemistry Adult Reference Ranges
Certified correct on 28/06/2016 Biochemistry Adult Reference Ranges Test Reference range Units Reference range from Traceable to standard reference material Albumin 35 50 g/l Pathology IRMM ERM-DA470k/IFCC
More informationREAD HIGHLIGHTED CHANGES
BIO-FLASH anti-hbs 3000-8581 100 tests The BIO-FLASH anti-hbs is a fully automated chemiluminescent simultaneous immunoassay for quantitative measurement of antibodies to Hepatitis B surface antigen (anti-hbs)
More informationRubella Latex Agglutination Test
Rubella Latex Agglutination Test Cat. No.:DLAT1088 Pkg.Size:30T Intended use The Rubella Latex Agglutination Test is a rapid latex particle agglutination test for the qualitative and semi-quantitative
More informationPOC Testing: The New Standard. InnovaStar From DiaSys.
POC Testing: The New Standard. InnovaStar From DiaSys. Easy to use, superior precision, rapid results: InnovaStar from DiaSys brings POC testing to a whole new level. A fully automatic, compact analyzer
More informationPRODUCT CATALOGUE YOUR GLOBAL PARTNER IN DIAGNOSTICS
PRODUCT CATALOGUE YOUR GLOBAL PARTNER IN DIAGNOSTICS WELCOME Omega Diagnostics Ltd is a wholly owned subsidiary of Omega Diagnostics Group PLC. Formed in 1987, Omega is one of the UK s leading manufacturers
More informationPlasma proteins Quantitatively, proteins are the most important part of the soluble components of the blood plasma.
Plasma proteins 42 Plasma proteins Quantitatively, proteins are the most important part of the soluble components of the blood plasma. concentrations of between 60 and 80 g L 1, they constitute approximately
More informationREAGENTS THE HIGHEST QUALITY RANGE OF ROUTINE AND NOVEL REAGENTS
THE HIGHEST QUALITY RANGE OF ROUTINE AND NOVEL REAGENTS Advancing Biochemistry Testing for Laboratories CONTENTS 01 06 43 46 53 55 60 BENEFITS OF RANDOX REAGENTS REAGENTS - RANDOX THIRD PARTY REAGENTS
More informationTowards a Certified Reference Material for HbA 2
Towards a Certified Reference Material for HbA 2 amalia.munoz-pineiro@ec.europa.eu Joint Research Centre Serving society Stimulating innovation Supporting legislation CRM What are Reference Materials (RMs)?
More informationPrevalent of Post streptococcal Infections among renal failure patients in Khartoum state
EUROPEAN ACADEMIC RESEARCH Vol. IV, Issue 8/ November 6 ISSN 86-8 www.euacademic.org Impact Factor:.56 (UIF) DRJI Value: 5.9 (B+) Prevalent of Post streptococcal Infections among renal failure TASABEEH
More informationhuman Total Cathepsin B Catalog Number: DY2176
human Total Cathepsin B Catalog Number: DY2176 This DuoSet ELISA Development kit contains the basic components required for the development of sandwich ELISAs to measure natural and recombinant human Total
More informationPRODUCT DATA SHEET. Human IgE MICRO-ELISA Test Kit
Human IgE MICRO-ELISA Test Kit Prod. No.: Pkg. Size: T177 96 Tests Description The MICRO-ELISA IMMUNOGLOBULIN E (IgE) test is a solid phase sandwich-type enzyme immunoassay (ELISA) Diagnostic Kit for the
More informationabia IgE total ref DK ivd Note: Changes highlighted
abia IgE total ref DK.048.01.3 ivd Note: Changes highlighted Intended use abia IgE total enzyme immunoassay for the quantitative determination of total immunoglobulin E (IgE) concentration in human serum.
More informationQuantitative estimation of protein in urine
Quantitative estimation of protein in urine By sulphosalicalic acid Method BCH 472 In a healthy renal and urinary tract system, the urine contains no protein or only trace amounts. The presence of increased
More informationSecondary fluorescent staining of virus antigens by rheumatoid factor and fluorescein-conjugated anti-lgm
Ann. rheum. Dis. (1973), 32, 53 Secondary fluorescent staining of virus antigens by rheumatoid factor and fluorescein-conjugated anti-lgm P. V. SHIRODARIA, K. B. FRASER, AND F. STANFORD From the Department
More informationMeasles IgM ELISA Kit
Measles IgM ELISA Kit Catalog Number KA2257 96 assays Version: 03 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle of the Assay...
More informationD-Immunologic Detection of Microorganisms
D-Immunologic Detection of Microorganisms Immunologic methods take advantage of the specificity of antigenantibody binding. For example, known antigens and antibodies are used as diagnostic tools in identifying
More informationLIAISON Measles IgG The fully automated solution for quantitative antibody detection
LIAISON Measles IgG The fully automated solution for quantitative antibody detection FOR OUTSIDE THE US AND CANADA ONLY LIAISON Measles IgG Number of tests 100 Key assay features Method Assay range Solid
More informationInsulin (Porcine/Canine) ELISA
Insulin (Porcine/Canine) ELISA For the quantitative measurement of insulin in Porcine/Canine serum and plasma (EDTA) For Research Use Only. Not For Use In Diagnostic Procedures. Catalog Number: 80-INSPO-E01
More informationCOMPONENT NAME COMPONENT # QUANTITY STORAGE SHELF LIFE FORMAT. Store at 2-8 C. Do not freeze. Store at 2-8 C. Do not freeze.
This document is available at www.stemcell.com/pis Catalog #18765 EasySep Mouse CD4+CD62L+ T Cell Isolation Kit For processing 1x 10^9 cells Description Isolate highly purified naïve CD4+ T cells (CD4+CD62L+)
More informationCOMPONENT NAME COMPONENT # QUANTITY STORAGE SHELF LIFE FORMAT. Store at 2-8 C. Do not freeze. Store at 2-8 C. Do not freeze.
This document is available at www.stemcell.com/pis Catalog #18765 EasySep Mouse CD4+CD62L+ T Cell Isolation Kit For processing 1x 10^9 cells Description Isolate highly purified naïve CD4+ T cells (CD4+CD62L+)
More informationWHO Prequalification of Diagnostics Programme PUBLIC REPORT
WHO Prequalification of Diagnostics Programme PUBLIC REPORT Product: Murex HBsAg Version 3 with Murex HBsAg Confirmatory Version 3 Number: PQDx 0121-043-00 Abstract Murex HBsAg Version 3 with Murex HBsAg
More informationTRACEABILITY and UNCERTAINTY 9
AAT Antitrypsin alpha 1 AAGP Acid glycoprotein alpha 1 immunoturbidimetric Gen. Acid phosphatase total 1-naphthyl phosphate Gen. Acid phosphatase total 1-naphthyl phosphate Gen. Integra 00 plus Acid phosphatase,
More informationCHEMILUMINESCENCE ENZYME IMMUNOASSAY (CLIA) (IgE) IgE
DIAGNOSTIC AUTOMATION, INC. 21250 Califa Street, Suite 102 and 116, Woodland Hills, California 91367 USA Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com
More informationMycoplasma pneumoniae IgG ELISA Kit
Mycoplasma pneumoniae IgG ELISA Kit Catalog Number KA2260 96 assays Version: 01 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle
More informationDIAZYME PRODUCT LIST LIST INNOVATIONS IN CLINICAL DIAGNOSTICS
DIAZYME PRODUCT LIST LIST PRODUCT 2 13 INNOVATIONS IN CLINICAL DIAGNOSTICS About Diazyme Diazyme Laboratories is a Division of General Atomics located in Poway, California. Diazyme uses its proprietary
More informationFinTest IgG4 Screen 20 ELISA KIT
FinTest IgG4 Screen 20 ELISA KIT Cat. No.:DEIA6196 Pkg.Size:96T Intended use Enzyme immunoassay (microtiter strips) for the detection and the quantitative determination of IgG4 antibodies against 20 Food
More informationUrinary Collagen IV EIA
Urinary Collagen IV EIA Enzyme Immunoassay Instructions for Use FOR RESEARCH USE ONLY Not for use in Diagnostic Procedures ACTIF 3-27-3 Kyodo, Setagaya-ku, Tokyo 1560052 JAPAN TEL&FAX: +81(0)3-6413-1860
More informationRapid-VIDITEST. Influenza A
Rapid-VIDITEST Influenza A (One step Influenza A Card test for the detection of Influenza type A antigen from human nasopharyngeal specimens (swab, nasopharyngeal wash and aspirate). Instruction manual
More informationPERIOSTIN ELISA CONTENTS
PERIOSTIN ELISA for the quantitative determination of Periostin in human serum, EDTA plasma, heparin plasma, and citrate plasma Cat. No. BI-20433. 12 x 8 tests CONTENTS ASSAY CHARACTERISTICS Summary...
More informationGentian Canine CRP Immunoassay Application Note for Abbott Architect * c4000
v2-jan214 Gentian Canine CRP Immunoassay Application Note for Abbott Architect * c4 Intended Use The canine CRP immunoassay on Abbott's Architect c4 is an in vitro diagnostic test for quantitative determination
More informationMouse Anti-OVA IgM Antibody Assay Kit
Mouse Anti-OVA IgM Antibody Assay Kit Catalog # 3017 For Research Use Only - Not Human or Therapeutic Use INTRODUCTION Ovalbumin (OVA) is a widely used antigen for inducing allergic reactions in experimental
More informationPorcine/Canine Insulin ELISA
Porcine/Canine Insulin ELISA For the quantitative determination of insulin in porcine or canine serum and plasma. Please read carefully due to Critical Changes, e.g., Calculation of Results. For Research
More informationGentian Canine CRP Immunoassay Application Note for scil VitroVet*
v02-jan2014 Gentian Canine CRP Immunoassay Application Note for scil VitroVet* Intended Use The canine CRP immunoassay on scil VitroVet is an in vitro diagnostic test for quantitative determination of
More informationHuman Influenza A (Swine Flu) Rapid test
Human Influenza A (Swine Flu) Rapid test Cat.No: DTSXY-Z9 Lot. No. (See product label) Size 20T Intended use The Influenza A (Swine Flu) test is a rapid chromatographic immunoassay for the qualitative
More informationHumaTex Febrile Antigens
Design Verification HumaTex Febrile Antigens Contents 1 Function... 2 2 Product Line... 2 3 Sensitivity... 2 Description of Control Materials... 2 Kit controls Positive and Negative... 3 4 Interferences...
More informationFecal H. pylori Antigen Rapid Test (Strip)
Fecal H. pylori Antigen Rapid Test (Strip) Cat. No.:DTS526 Pkg.Size: Intended use This H. pylori Antigen Rapid Test is intended for the direct qualitative detection of the presence of H. pylori antigen
More informationChlamydia Trachomatis IgM ELISA Kit
Chlamydia Trachomatis IgM ELISA Kit Catalog Number KA0960 96 assays Version: 03 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle
More information7/31/2018. Overview of Next Generation Cardiac Troponin T High Sensitivity. Disclosures. Course Objectives: high sensitive Troponin T assay
Overview of Next Generation Cardiac Troponin T High Sensitivity Arleen Francis Medical & Scientific Liaison Roche Diagnostics 1 Disclosures Arleen Francis is an employee of Roche Diagnostics and a member
More informationPS + MPs PS - MPs 37% 36% 64% 64%
Supplementary Figure 1. Amount and distribution of phosphatidylserine negative (PS - ) and phosphatidylserine positive (PS + ) MPs in 280 SLE patients and 280 controls. Circles are proportional to the
More informationQuantitative protein estimation of Urine
Quantitative protein estimation of Urine 1 In a healthy renal and urinary tract system, the urine contains no protein or only trace amounts. The presence of increased amounts of protein in the urine can
More informationDengue IgG/IgM/NS1 Combo Rapid Test Device
Dengue IgG/IgM/NS1 Combo Rapid Test Device Cat.No: DTSXY-L2 Lot. No. (See product label) Intended Use The Dengue IgG/IgM/NS1 Combo Rapid Test Device is a lateral flow chromatographic immunoassay for the
More informationRHEUMATIC FEVER RHF-1. Disease name. Basis of diagnosis
RHF-1 RHEUMATIC FEVER Disease name Disease Indicate whether this is an initial (i.e first) attack of rheumatic fever or a recurrent attack (an episode in a person with known past history of acute rheumatic
More informationStandard Operating Procedure
Subject Free Thyroxine (FT4-II) cobas e411 Index Number Lab-1594 Section Regional/Affiliate Subsection Laboratory Category Departmental Contact Goplin, Darcy Last Revised 2/2/2017 References Required document
More informationMouse Total IgA Antibody Detection Kit
Mouse Total IgA Antibody Detection Kit Catalog # 3019 For Research Use Only - Not Human or Therapeutic Use INTRODUCTION The total IgA levels in specimens are often determined in mouse disease models involving
More informationThe NGAL Turbidimetric Immunoassay Reagent Kit
Antibody and Immunoassay Services Li Ka Shing Faculty of Medicine, University of Hong Kong The NGAL Turbidimetric Immunoassay Reagent Kit Catalogue number: 51300 For the quantitative determination of NGAL
More informationCreatinine & egfr A Clinical Perspective. Suheir Assady MD, PhD Dept. of Nephrology & Hypertension RHCC
Creatinine & egfr A Clinical Perspective Suheir Assady MD, PhD Dept. of Nephrology & Hypertension RHCC CLINICAL CONDITIONS WHERE ASSESSMENT OF GFR IS IMPORTANT Stevens et al. J Am Soc Nephrol 20: 2305
More informationSummary of Recommendation Statements Kidney International Supplements (2013) 3, 5 14; doi: /kisup
http://www.kidney-international.org & 2013 DIGO Summary of Recommendation Statements idney International Supplements (2013) 3, 5 14; doi:10.1038/kisup.2012.77 Chapter 1: Definition and classification of
More informationEndogenous antibody interference in immunoassays. Ellen Anckaert, M.D., Ph.D. Dienst Klinische Chemie en Radio-immunologie UZ Brussel
Endogenous antibody interference in immunoassays Ellen Anckaert, M.D., Ph.D. Dienst Klinische Chemie en Radio-immunologie UZ Brussel To help protect your privacy, PowerPoint has blocked automatic download
More informationRapid-VIDITEST. Astrovirus Card
Rapid-VIDITEST Astrovirus Card One step Astrovirus Card Test. Instruction manual INTENDED USE: The Rapid-VIDITEST Astrovirus Card is a one step coloured chromatographic immunoassay for the qualitative
More information5/10/2014. Observation, control of blood pressure. Observation, control of blood pressure and risk factors.
Overview The Kidneys Nicola Barlow Clinical Biochemistry Department City Hospital Renal physiology Renal pathophysiology Acute kidney injury Chronic kidney disease Assessing renal function GFR Proteinuria
More informationTechnical Bulletin. Performance Characteristics of the BN ProSpecä System. By Liana Frances Romero, BS, MT(ASCP)
Technical Bulletin Performance Characteristics of the BN ProSpecä System By Liana Frances Romero, BS, MT(ASCP) Introduction The BN ProSpecä System is an automated nephelometry analyzer for in vitro diagnostic
More informationHuman Allergen Specific IgE ELISA Kits
Intended Use Human Allergen Specific IgE ELISA Kits These kits are in vitro assays for the qualitative or quantitative detection of allergen-specific IgE antibodies in human serum. They are intended for
More informationImmunology. Lecture- 8
Immunology Lecture- 8 Immunological Disorders Immunodeficiency Autoimmune Disease Hypersensitivities Immunodeficiency 1. Immunodeficiency --> abnormal production or function of immune cells, phagocytes,
More informationMetabolic Syndrome. Antibodies and antigens
Metabolic Syndrome Antibodies and antigens HYTEST METABOLIC SYNDROME Introduction Metabolic syndrome is a cluster of conditions that increases the likelihood of cardiovascular heart diseases and diabetes.
More informationCHEMILUMINESCENCE ENZYME IMMUNOASSAY (CLIA) (IgE) IgE. Cat #
DIAGNOSTIC AUTOMATION, INC. 21250 Califa Street, Suite 102 and 116, Woodland Hills, California 91367 USA Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com
More informationFor questions 1-5, match the following with their correct descriptions. (24-39) A. Class I B. Class II C. Class III D. TH1 E. TH2
Questions Made by SI ATTENDEES!! :) Page 1 of 6 Student-Made Practice Exam Activity All questions, answers, and slide numbers are based off of Monday s SI activity, where students/attendees created possible
More informationcobas c 501 analyzer and cobas c 311 analyzer Within Run Imprecision Guidelines
cobas c 501 analyzer and cobas c 311 analyzer General Information How to use these guidelines Unless otherwise indicated, the data presented is the same for both the cobas c 501 analyzer and the cobas
More informationDIAZYME PRODUCT LIST LIST INNOVATIONS IN CLINICAL DIAGNOSTICS
DIAZYME PRODUCT LIST LIST PRODUCT 2 14 INNOVATIONS IN CLINICAL DIAGNOSTICS About Diazyme Diazyme Laboratories is a Division of General Atomics located in Poway, California. Diazyme uses its proprietary
More informationMouse GLP-2 EIA. Cat. No. KT-374. For the quantitative determination of GLP-2 in mouse serum or plasma. For Research Use Only. 1 Rev.
Mouse GLP-2 EIA For the quantitative determination of GLP-2 in mouse serum or plasma. Cat. No. KT-374 For Research Use Only. 1 Rev. 11357374 PRODUCT INFORMATION Mouse GLP-2 EIA Cat. No. KT-374 INTENDED
More informationLuke Droney IMMUNOGLOBULIN LEVELS AND FUNCTION
IMMUNOGLOBULIN LEVELS AND FUNCTION Interpret changes in immunoglobulin levels within the clinical context including - Immunodeficiency - Disorders characterised by hypergammaglobulinaemia, rheumatoid arthritis,
More informationshort catalogue clinical chemistry immunoturbidimetric tests calibrators standards controls supplementary reagents instruments Probedruck ::018 ::016
DiaSys_Kurzkatalog_2015_141209 10.12.2014 12:07 Uhr Seite 1 C ::010 ::011 ::012 ::013 ::014 M Y CM MY ::015 CY CMY K ::016 ::017 15 short catalogue ::026 ::027 ::028 ::029 ::036 ::030 ::037 ::018 ::031
More informationDIAZYME PRODUCT LIST LIST INNOVATIONS IN CLINICAL DIAGNOSTICS
DIAZYME PRODUCT LIST LIST PRODUCT 2 15 INNOVATIONS IN CLINICAL DIAGNOSTICS About Diazyme Diazyme Laboratories is a Division of General Atomics located in Poway, California. Diazyme uses its proprietary
More informationRF IgM (Rheumatoid Factor) (EIA-2775)
INTENDED USE The DRG Rheumatoid Factor (RF) IgM ELISA test system is intended for the qualitative and semi-quantitative detection of RF IgM-class antibody in human serum. The test system is intended to
More informationEXCELLENT CORRELATION OF ACTIM CRP WITH QUANTITATIVE INSTRUMENT RESULTS
EXCELLENT CORRELATION OF ACTIM CRP WITH QUANTITATIVE INSTRUMENT RESULTS Results of Actim CRP test were compared to quantitative results obtained by different instruments. Different sample types were also
More informationInsulin ELISA. For the quantitative determination of insulin in serum and plasma.
Insulin ELISA For the quantitative determination of insulin in serum and plasma. For In Vitro Diagnostic use within the United States of America. This product is for Research Use Only outside of the United
More informationRat Insulin ELISA. For the quantitative determination of insulin in rat serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.
Rat Insulin ELISA For the quantitative determination of insulin in rat serum and plasma For Research Use Only. Not For Use In Diagnostic Procedures. Catalog Number: Size: 80-INSRT-E01, E10 96 wells, 10
More informationToxoplasma gondii IgM (Toxo IgM)
DIAGNOSTIC AUTOMATION, INC. 21250 Califa Street, Suite 102 and116, Woodland Hills, CA 91367 Tel: (818) 591-3030 Fax: (818) 591-8383 onestep@rapidtest.com technicalsupport@rapidtest.com www.rapidtest.com
More informationRat C-peptide ELISA. For the quantitative determination of C-peptide in rat serum. For Research Use Only. Not For Use In Diagnostic Procedures.
Rat C-peptide ELISA For the quantitative determination of C-peptide in rat serum. For Research Use Only. Not For Use In Diagnostic Procedures. Catalog Number: Size: 80-CPTRT-E01 96 wells Version: May 26,
More informationANTI-COLLAGEN TYPE IV IgG SUBCLASSES AND THE DEVELOPMENT OF DIABETIC MICROVASCULAR COMPLICATIONS
Division of Biology, Department of Biology and Pathological Physiology University School of Medicine 1, St. Kliment Ohridski Street 58 Pleven, Bulgaria E-mail: nicoloff_bg@yahoo.com Original Scientific
More information