InfinityLab Purification Capillary Kits

Size: px
Start display at page:

Download "InfinityLab Purification Capillary Kits"

Transcription

1 InfinityLab Purification Capillary Kits Technical Note This note describes the capillary connections for Agilent preparative systems. Agilent Technologies

2 Contents Abbreviations 3 List of Modules 4 Overview 5 General Installation Notes 5 Installation Notes for 1260 Infinity II Column Organizer G9328A 6 Installation Notes for 1290 Infinity II Column Compartment G7163B 8 Configurations with 1260 Infinity II Column Organizer (G9328A) 10 Entry Level System Configurations (with Manual Injector) 10 Standard UV/LC System Configurations 16 Standard Mass-Based Systems Configuration 24 Configurations with 1290 Infinity II Preparative Column Compartment (G7163B) 28 Entry Level System Configurations (with Manual Injector) 28 Standard UV/LC System Configurations 34 Standard Mass-Based System Configurations 40 Accessories 44 UV Accessories 44 MS Accessories 44 2

3 Abbreviations Table 1 Abbreviations Modules VWD Variable wavelength detector Diode array detector MI Manual Injector DC Delay Coil Organizer RC Recovery collector FC Fraction collector PRV Pressure relieve valve BPR Back pressure regulator FM Flow modulator Fittings R fitting for flex capillaries: for rigid capillaries: S lock fitting Capillaries and tubings UV1...5 Capillaries to connect the s of the liquid chromatographic part of the system MS1...6 Capillaries to connect the s of the mass spectrometric part of the system 0.3f 0.3 ID flex capillary 0.5r 0.5 ID rigid capillary ESD Electrostatic discharge Material SST Stainless steel PTFE Polytetrafluorethylene PEEK Polyether ether ketone 3

4 List of Modules Table 2 G7161A G7161B G7114A G7115A G7165A G7159B G7166A G1364E G1328D G7157A G7170B G9324A List of s 1260 Infinity II Preparative Binary Pump 1290 Infinity II Preparative Binary Pump 1260 Infinity II Variable Wavelength Detector 1260 Infinity II Diode Array Detector WR 1260 Infinity II Multiple Wavelength Detector 1290 Infinity II Preparative Open-Bed Fraction Collecor 1260 Infinity II Preparative Valve-Based Fraction Collector 1260 Infinity II Preparative Fraction Collector 1260 Infinity II Manual Preparative Injector 1260 Infinity II Preparative Autosampler 1290 Infinity II MS Flow Modulator 1260 Infinity II Delay Coil Organizer PREP Pressure Relief Valve Kit G7163B G9328A G7110A 1290 Infinity II Preparative Column Compartment 1260 Infinity II Column Organizer 1260 Infinity II Isocratic Pump ERI Remote and Leak Module G6125B MSD 4

5 Overview General Installation Notes Capillaries and Fittings Capillary UV/LC kits ( , , , ) are flow dependent. The proper kit needs to be selected based on the desired flow range. The MS Upgrade kit ( ) is only one kit. It contains all capillaries for all flow ranges. Four capillaries (UV2A, 2B, 2C, 2D) are provided to connect sampler and column. All capillaries with an inner diameter (ID) of 0.3 and 0.5 are flexible. Only the MS1B capillary from column to flow modulator is always rigid. This capillary is guided between s and needs to remain in its fixed position. The bypass of the flow modulator is part of accessory kit G All capillaries going to the ports of the flow modulator need UHP-FF fittings. NOTE Do not use swagelock for the flow modulator, the ports can be damaged. The Multiple Wavelength Detector is not depicted in the drawings. The same principles as for the Diode Array Detector apply. Only removable fittings are used for columns. Either Quick Turn Fittings for flexible capillaries, or UHP-FF for rigid capillaries. General rules If the height of the stack configuration exceeds the safety limit (0.89 m), the solvent cabinet has to be placed next to the stack on the base plate. The base plate is needed in case the Solvent Cabinet is placed on a bench by itself, and has to be ordered separately (p/n G ). 5

6 Installation Notes for 1260 Infinity II Column Organizer G9328A Columns and Column Holders To keep the capillary from column to detector as short as possible, the column needs to be mounted at the highest possible position, and in the front of the column organizer. Two capillaries (UV2A, UV2B) are provided to connect sampler and column: UV2A is used for columns shorter than 15 cm, UV2B is used for long columns of 15 cm and more. Fix columns with the following column holders: M size holders ( ) for 9.4 /10, 21.2 and 30 columns, L size holders (G ) for 50 columns, L size holders have to be ordered separately. The 25 cm columns require two M size holders, shorter columns need only one holder. One M holder can be used for pre-column. Manual Injection Valve G1328D (MI) The MI must be installed in the first groove of the column organizer extrusion plate. The MI can be installed at any height. In combination with columns shorter than 25 cm, the MI can be positioned in the middle of the column organizer. In combination with columns 25 cm or longer, the MI needs to be installed at the lowest possible position. The MI requires a suitable waste container (bottle or beaker) for waste and siphoning capillaries. NOTE The kit does not contain a waste container. The waste container must be provided by the customer. The waste container has to be placed on the leak plate. 6

7 In the case that a 20 ml stainless steel loop is used, it has to be bent in the direction of the extrusion to leave enough space for the container on the leak plate. None of the other loops limit the space for the container. The waste and siphoning capillaries have to be bent. The end of the capillaries have to be at the same height as the position of the injection needle. Pressure Relieve Valve (PRV, ) and Back Pressure Regulator (BPR, ) PRV must be installed with every configuration. NOTE The PRV is required for safety reasons. The PRV and BPR come with the Preparative LC system. The PRV is installed at the outlet of the Delay Coil Organizer, if available. If the PRV is used as a single item, the following measures are required: The PRV has to be connected with system tubing from the detector. This connection requires union to ¼-28. The PRV has to be fixed to the column organizer using S holders. The PRV has to be placed on the upper part of the extrusion. NOTE The length of the capillary from the detector to the PRV is intentionally limited. The PRV waste tubing is guided to the leak plate by S holders. The BPR needs to be installed ahead of the Recovery Collector. The use of BPR is recoended only for certain flow rates, check for operating instructions. The BPR can be fixed at any position on the extrusion using S holders. 7

8 Installation Notes for 1290 Infinity II Column Compartment G7163B General The Delay Coil Organizer must be installed at the highest valve position. The Flow Modulator must be installed in the second highest valve position. The Recovery Collector can be installed at any available free valve position. Columns and Column Holders The column should be mounted at the highest possible position of the Column Compartment. The capillaries UV2A, UV2B, UV2C and UV2D are used to connect the column with the sampler. Select the suitable capillary length depending on the position or length of the column. Fix columns with the following column holders: M size holders ( ) for 9.4 /10, 21.2 and 30 columns, L size holders (G ) for 50 columns, The 25 cm columns require two M size holders, shorter columns need only one M size holder. One M size holder can be used for pre-column. Manual Injection Valve G1328D (MI) The MI should be installed on the bottom part of the small mounting plate of the Column Compartment in the first groove. The MI requires a suitable waste container (bottle or beaker) for waste and siphoning capillaries. NOTE The kit does not contain a waste container. The waste container must be provided by the customer. The waste container has to be placed on the plateau of the Column Compartment. Columns need to be installed such that they do not collide with MI, loop or siphoning capillaries, usually on the left part of the extrusion. 8

9 The waste and siphoning capillaries have to be bent. The end of the capillaries have to be at the same height as the position of injection needle and should point down to the waste container. Pressure Relieve Valve (PRV, ) and Back Pressure Regulator (BPR, ) PRV must be installed with every configuration. NOTE The PRV is required for safety reasons. The PRV and BPR come with the Preparative LC system. The PRV is installed at the outlet of the Delay Coil Organizer, if available. If the PRV is used as a single item, the following measures are required: The PRV has to be connected with system tubing from the detector. This connection requires union to ¼-28. The PRV has to be fixed to the Column Compartment using S holders ( ). The PRV has to be placed on the upper part of the extrusion. NOTE The length of the capillary from the detector to the PRV is intentionally limited. The PRV waste tubing is guided to the leak sensor by S holders. The use of BPR is recoended only for certain flow rates, check for operating instructions. The BPR can be fixed at any position on the extrusion using S holders. 9

10 Configurations with 1260 Infinity II Column Organizer (G9328A) Entry Level System Configurations (with Manual Injector) Entry Level System Configurations Table 3 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV kit for each flow rate Flow range 4 8mL/min ml/min 80 From To Length /cm Fittings UV1 Pump Sampler f UV2A Sampler Column f UV2B Sampler Column f UV3 Column VWD/ f UV4 VWD/ DC Box/ PRV f r UV5 VWD/ PRV f

11 Table 4 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G ) Tubing Kit 50 (G ) Tubing Kit 150 (G ) Tubing Kit 200 (G ) Suitable for the flow up to 1 8 ml/min ml/min ml/min 150 Table 5 Preparative Fraction Collector tubing kits (G1364E) P/N Preparative Fraction Collector tubing kit G G G Coent 4 8 ml/min ml/min 11

12 12

13 Entry Level System Configurations with Delay Coil Organizer (G9324A) Table 6 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV kit for each flow rate Flow range 4 8mL/min ml/min 80 From To Length /cm Fittings UV1 Pump Sampler f UV2A Sampler Column f UV2B Sampler Column f UV3 Column VWD/ f UV4 VWD/ DC Box/ PRV f r UV5 VWD/ PRV f Table 7 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G ) Tubing Kit 50 (G ) Tubing Kit 150 (G ) Tubing Kit 200 (G ) Suitable for the flow up to 1 8 ml/min ml/min ml/min

14 Table 8 Preparative Fraction Collector tubing kits (G1364E) P/N Preparative Fraction Collector tubing kit G G G Coent 4 8 ml/min ml/min 14

15 15

16 Standard UV/LC System Configurations Configuration with Preparative Open-Bed Fraction Collector Table 9 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV kit for each flow rate Flow range 4 8mL/min ml/min 80 From To Length /cm Fittings UV1 Pump Sampler f UV2A Sampler Column f UV2B Sampler Column f UV3 Column VWD/ f UV4 VWD/ DC Box/ PRV f r UV5 VWD/ PRV f Table 10 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G ) Tubing Kit 50 (G ) Tubing Kit 150 (G ) Tubing Kit 200 (G ) Suitable for the flow up to 1 8 ml/min ml/min ml/min

17 17

18 Configuration with Preparative Open-Bed Fraction Collector and Delay Coil Organizer (G9324) Table 11 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV kit for each flow rate Flow range 4 8mL/min ml/min 80 From To Length /cm Fittings UV1 Pump Sampler f UV2A Sampler Column f UV2B Sampler Column f UV3 Column VWD/ f UV4 VWD/ DC Box/ PRV f r UV5 VWD/ PRV f Table 12 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G ) Tubing Kit 50 (G ) Tubing Kit 150 (G ) Tubing Kit 200 (G ) Suitable for the flow up to 1 8 ml/min ml/min ml/min

19 19

20 Configuration with Preparative Fraction Collector Table 13 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV kit for each flow rate Flow range 4 8mL/min ml/min 80 From To Length /cm Fittings UV1 Pump Sampler f UV2A Sampler Column f UV2B Sampler Column f UV3 Column VWD/ f UV4 VWD/ DC Box/ PRV f r UV5 VWD/ PRV f Table 14 Preparative Fraction Collector tubing kits (G1364E) P/N Preparative Fraction Collector tubing kit G G G Coent 4 8 ml/min ml/min 20

21 21

22 Configuration with Preparative Fraction Collector and Delay Coil Organizer (G9324) Table 15 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV kit for each flow rate Flow range 4 8mL/min ml/min 80 From To Length /cm Fittings UV1 Pump Sampler f UV2A Sampler Column f UV2B Sampler Column f UV3 Column VWD/ f UV4 VWD/ DC Box/ PRV f r UV5 VWD/ PRV f Table 16 Preparative Fraction Collector tubing kits (G1364E) P/N Preparative Fraction Collector tubing kit G G G Coent 4 8 ml/min ml/min 22

23 23

24 Standard Mass-Based Systems Configuration Table 17 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV kit for each flow rate Flow range 4 8mL/min ml/min 80 From To Length /cm Fittings UV1 Pump Sampler f UV2A Sampler Column f UV2B Sampler Column f UV3 Column VWD/ f UV4 VWD/ DC Box/ PRV f r UV5 VWD/ PRV f

25 Table 18 Upgrade Capillary kit MS-Based Prep LC Upgrade Capillary kit MS-Based Prep LC No kit 4 8mL/min ml/min 80 1 kit only From To Length /cm ID / No. ID / No. ID / No. ID / No. Fittings MS1B Column Flow modul r r MS2 Flow modul. VWD/ f MS3 Make up Flow modul FLOW INDEPENDENT CAPILLARIES MS4 Flow modul. MS MS5 MS restriction capillary MS6 MS waste capillary NON Table 19 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G ) Tubing Kit 50 (G ) Tubing Kit 150 (G ) Tubing Kit 200 (G ) Suitable for the flow up to 1 8 ml/min ml/min ml/min

26 Table 20 Preparative Fraction Collector tubing kits (G1364E) P/N Preparative Fraction Collector tubing kit G G G Coent 4 8 ml/min ml/min Length/cm No. Fittings FM FM

27 27

28 Configurations with 1290 Infinity II Preparative Column Compartment (G7163B) Entry Level System Configurations (with Manual Injector) Entry Level System Configuration Table 21 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV kit for each flow rate Flow range 4 8mL/min ml/min 80 From To Length /cm Fittings UV1 Pump Sampler f UV2A Sampler Column f UV2B Sampler Column f UV2C Sampler Column f UV2D Sampler Column f UV3 Column VWD/ f UV4 VWD/ DC Box/ PRV f r

29 Table 22 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G ) Tubing Kit 50 (G ) Tubing Kit 150 (G ) Tubing Kit 200 (G ) Suitable for the flow up to 1 8 ml/min ml/min ml/min 150 Table 23 Preparative Fraction Collector tubing kits (G1364E) P/N Preparative Fraction Collector tubing kit G G G Coent 4 8 ml/min ml/min 29

30 30

31 Entry Level System Configuration with Delay Coil Organizer (G9324A) Table 24 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV kit for each flow rate Flow range 4 8mL/min ml/min 80 From To Length /cm Fittings UV1 Pump Sampler f UV2A Sampler Column f UV2B Sampler Column f UV2C Sampler Column f UV2D Sampler Column f UV3 Column VWD/ f UV4 VWD/ DC Box/ PRV f r Table 25 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G ) Tubing Kit 50 (G ) Tubing Kit 150 (G ) Tubing Kit 200 (G ) Suitable for the flow up to 1 8 ml/min ml/min ml/min

32 Table 26 Preparative Fraction Collector tubing kits (G1364E) P/N Preparative Fraction Collector tubing kit G G G Coent 4 8 ml/min ml/min 32

33 33

34 Standard UV/LC System Configurations Standard UV/LC System Configurations Table 27 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV kit for each flow rate Flow range 4 8mL/min ml/min 80 From To Length /cm Fittings UV1 Pump Sampler f UV2A Sampler Column f UV2B Sampler Column f UV2C Sampler Column f UV2D Sampler Column f UV3 Column VWD/ f UV4 VWD/ DC Box/ PRV f r

35 Table 28 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G ) Tubing Kit 50 (G ) Tubing Kit 150 (G ) Tubing Kit 200 (G ) Suitable for the flow up to 1 8 ml/min ml/min ml/min 150 Table 29 Preparative Fraction Collector tubing kits (G1364E) P/N Preparative Fraction Collector tubing kit G G G Coent 4 8 ml/min ml/min 35

36 36

37 Standard UV/LC System Configurations with Delay Coil Organizer (G9328A) Table 30 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV kit for each flow rate Flow range 4 8mL/min ml/min 80 From To Length /cm Fittings UV1 Pump Sampler f UV2A Sampler Column f UV2B Sampler Column f UV2C Sampler Column f UV2D Sampler Column f UV3 Column VWD/ f UV4 VWD/ DC Box/ PRV f r Table 31 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G ) Tubing Kit 50 (G ) Tubing Kit 150 (G ) Tubing Kit 200 (G ) Suitable for the flow up to 1 8 ml/min ml/min ml/min

38 Table 32 Preparative Fraction Collector tubing kits (G1364E) P/N Preparative Fraction Collector tubing kit G G G Coent 4 8 ml/min ml/min 38

39 39

40 Standard Mass-Based System Configurations Table 33 Capillary Kit Prep UV/LC Overview System Capillary Kit Prep LC/UV kit for each flow rate Flow range 4 8mL/min ml/min 80 From To Length /cm Fittings UV1 Pump Sampler f UV2A Sampler Column f UV2B Sampler Column f UV2C Sampler Column f UV2D Sampler Column f UV3 Column VWD/ f UV4 VWD/ DC Box/ PRV f r

41 Table 34 Upgrade Capillary kit MS-Based Prep LC Upgrade Capillary kit MS-Based Prep LC No kit 4 8mL/min ml/min 80 1 kit only From To Length /cm ID / No. ID / No. ID / No. ID / No. Fittings MS1A Column Flow modul f MS2 Flow modul. VWD/ f MS3 Make up Flow modul FLOW INDEPENDENT CAPILLARIES MS4 Flow modul. MS MS5 MS restriction capillary MS6 MS waste capillary NON Table 35 Preparative Open-Bed Fraction Collector tubing kits (G7159B) P/N Preparative Open-Bed Fraction Collector tubing kit Tubing Kit 8 (G ) Tubing Kit 50 (G ) Tubing Kit 150 (G ) Tubing Kit 200 (G ) Suitable for the flow up to 1 8 ml/min ml/min ml/min

42 Table 36 Preparative Fraction Collector tubing kits (G1364E) P/N Preparative Fraction Collector tubing kit G G G Coent 4 8 ml/min ml/min Length/cm No. Fittings FM FM

43 43

44 Accessories UV Accessories Table 37 Accessories for kits , , , A-Line Quick Turn LC Fitting for Column 2 pcs for kits and UHP-FF FITTING for Column 2 pcs for kits and m Tube ESD PTFE OD2.5 ID ESD-Fitting OD Union Flat-Bottom 1/4-28 ESD Plastic and PEEK tubing cutter Fitting-Handle Sealtight-Handle MS Accessories Table 38 Accessories 3 m Tube ESD PTFE OD 2.5 ID ESD-Fitting OD Fitting adapter to SST TEE-LOW DEAD VOLUME Fitting-Handle Sealtight-Handle NOTE The flow modulator bypass is part of the G Flow Modulator Accessory Kit. *G * *G * G Number: G Edition: 11/2017 Printed in Germany Agilent Technologies, Inc 2017 Agilent Technologies, Inc Hewlett-Packard-Strasse Waldbronn, Germany

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System Application Note Food Testing and Agriculture Mass-Based Purification of Natural Product Impurities Using an Agilent 126 Infinity II Preparative LC/MSD System Authors Florian Rieck and Jörg Hippler Agilent

More information

Chiral Multicolumn Method Development on the Agilent 1260 Infinity II SFC System

Chiral Multicolumn Method Development on the Agilent 1260 Infinity II SFC System Chiral Multicolumn Method Development on the Agilent 126 Infinity II SFC System Application Note Small Molecule Pharmaceuticals Author Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany Abstract

More information

Agilent 1260 Infinity Analytical SFC System

Agilent 1260 Infinity Analytical SFC System Agilent 1260 Infinity Analytical SFC System Installation Instructions: Checkout Procedure This technical note describes the checkout procedures for the Agilent 1260 Infinity Analytical SFC System. Contents

More information

Agilent 1260 Infinity Analytical Hybrid SFC/UHPLC system

Agilent 1260 Infinity Analytical Hybrid SFC/UHPLC system Agilent 1260 Infinity Analytical Hybrid SFC/UHPLC system Shared use of Columns - Technical Note This technical note describes the methods required to perform automated column switching in SFC/LC and SFC/LC/MS

More information

Chiral Screening for SFC and UHPLC with the Agilent 1260 Infinity II SFC/UHPLC Hybrid System

Chiral Screening for SFC and UHPLC with the Agilent 1260 Infinity II SFC/UHPLC Hybrid System Application Note Small Molecule Pharmaceutical Chiral Screening for SFC and UHPLC with the Agilent 16 Infinity II SFC/UHPLC Hybrid System Author Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

More information

ICP-OES Organics Kit Installation Instructions

ICP-OES Organics Kit Installation Instructions The ICP Organics Kit is an accessory for use with the Agilent ICP-OES instruments. It is available in two versions one for axial ICP-OES and the other for radial ICP-OES. It is used to analyze directly

More information

QuickSplitTM Flow Splitters

QuickSplitTM Flow Splitters QuickTM Flow ters between 2 or more detectors such as Mass Spectroscopy and evaporative light scattering, UV, or IR. This is especially important when one of the detectors is destructive, such as Mass

More information

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns

Maximizing Efficiency Using Agilent InfinityLab Poroshell 120 Columns Maximizing Efficiency Using Agilent InfinityLab Poroshell 12 Columns 1, Plates in Less Than Minutes Using Coupled Column Technology Application Note Food, Environmental, Chemical, Pharmaceutical Authors

More information

Performance Characteristics of the Agilent 1290 Infinity II Multicolumn Thermostat

Performance Characteristics of the Agilent 1290 Infinity II Multicolumn Thermostat Performance Characteristics of the Agilent 9 Infinity II Multicolumn Thermostat Technical Overview Author Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany Abstract This Technical Overview

More information

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate

Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Application Note Pharmaceutical QA/QC Author Siji Joseph Agilent Technologies, Inc. Bangalore,

More information

Comparison of a UPLC Method across Multiple UHPLC Systems

Comparison of a UPLC Method across Multiple UHPLC Systems Comparison of a UPLC Method across Multiple UHPLC Systems Tanya Jenkins Waters Corporation, Milford, MA, U.S. INTRODUCTION In 2004, Waters introduced the ACQUITY UPLC System. Since this launch, many liquid

More information

2D-LC as an Automated Desalting Tool for MSD Analysis

2D-LC as an Automated Desalting Tool for MSD Analysis 2D-LC as an Automated Desalting Tool for MSD Analysis Direct Mass Selective Detection of a Pharmaceutical Peptide from an MS-Incompatible USP Method Application Note Biologics and Biosimilars Author Sonja

More information

More accurate results.

More accurate results. More choices. More productivity. More accurate results. Agilent's Complete Line of Autosampler and Manual Syringes Specifications and Selection Guide Table of Contents Introduction to Agilent Syringes...2

More information

Performance characteristics of the Agilent 1100 Series preparative pump. Technical Note. Abstract

Performance characteristics of the Agilent 1100 Series preparative pump. Technical Note. Abstract Performance characteristics of the Agilent Series preparative pump Technical Note Abstract The Agilent Series preparative pump as part of the Agilent Series purification system is especially designed for

More information

Agilent 1220 Infinity LC System Performance Specifications

Agilent 1220 Infinity LC System Performance Specifications IET International Equipment Trading, Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 1220 Infinity LC System Performance

More information

Calibration Standards

Calibration Standards Calibration Standards/ Calibration Standards TSKgel standards polystyrene TSKgel standards poly(ethylene oxide) PStQuick polystyrene calibration standards TSKgel guard column products Fittings Pre-injector

More information

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system

Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system Maximizing chromatographic peak capacity with the Agilent 1290 Infinity LC system A practical guide on how to use parameters to increase peak capacity Application Note Pharmaceutical and Chemical Author

More information

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column

Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column Application Note Pharmaceutical and Food Testing Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column Author Lu Yufei Agilent Technologies, Inc. Abstract A liquid chromatographic

More information

PEEK SS Columns & Guard Columns

PEEK SS Columns & Guard Columns PEEK SS Columns & Guard Columns ~ Stainless Steel Analytical Columns ~ PEEK Columns ID 2.1, 4.0, 4.6 & 7.5 mm ~ Jour-Guard Cartridges Stainless Steel or PEEK ~ Stainless Steel End Fittings 1/4 OD Columns

More information

Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF

Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF Application Note 219 Joan Stevens, PhD; Luke Roenneburg; Kevin Fawcett (Gilson,

More information

Needle Gauge. Needle OD (mm) Needle ID (mm)

Needle Gauge. Needle OD (mm) Needle ID (mm) s LC Manual s Beckman/Altex, Rheodyne, SSI Instruments and Valco Valves s and Borosilicate Glass Barrel Outer Diameter () Scale 5 µl and 10 µl = 6.5 mm, 25 µl to 500 µl = 8 mm, 1 ml = 8.8 mm, 2.5 ml =

More information

Thermo Finnigan. 6-2 LCQ Advantage Getting Started-

Thermo Finnigan. 6-2 LCQ Advantage Getting Started- To set up the LCQ Advantage to acquire data in the APCI/MS mode, you do the following:.install the APCI probe assembly.set up to infuse your analyte into the MS detector using a syringe pump connected

More information

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System

Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 1290 Infinity LC System Increasing resolution using longer columns while maintaining analysis time Advantages of the wide power range of the Agilent 129 Infinity LC System Application Note Pharmaceutical and Chemical Analysis

More information

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP

Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 1 PFP Application Note Clinical Research Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd Abstract

More information

Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement

Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement Application Note Food Testing & Agriculture Author Edgar Naegele Agilent Technologies,

More information

Choose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide

Choose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide Choose for Your Instrument GC Supplies - Shimadzu Instrument Quick Pick Guide Syringes Septa Inlet Liners O-rings and Sealing Rings SilTite FingerTite Ferrules Ferrules Replacement Parts Your chromatography

More information

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract.

Application Note. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice. Author. Abstract. Agilent Application Solution Analysis of ascorbic acid, citric acid and benzoic acid in orange juice Application Note Author Food Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India 8 6 4 2

More information

Optimizing Chiral Separations and Purification of Enantiomers Through Selective Sample Slicing and Column Switching

Optimizing Chiral Separations and Purification of Enantiomers Through Selective Sample Slicing and Column Switching Optimizing Chiral Separations and Purification of Enantiomers Through Selective Sample Slicing and Column Switching Application Note PHA0113 Keywords Enantiomers, Purification, Chiral Pharmaceuticals,

More information

Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution

Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution Qualitative and quantitative determination of phenolic antioxidant compounds in red wine and fruit juice with the Agilent 1290 Infinity 2D-LC Solution Application Note Food Testing Author Edgar Naegele

More information

Application Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine-

Application Note. Small Molecule Pharmaceuticals. 2-Ethyl-2-phenylmalonamide Ethosuximide Primidone Carbamazepine. Carbamazepine- Analysis of Pharmaceutical Substances Using HPLC and UHPLC Methods Backward Compatibility for Validated Analytical Procedures and Methods Comparing the Infi nity LC and the Infi nity II LC Application

More information

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079

Ultra High Performance Liquid Chromatograph. Nexera X2 C196-E079 Ultra High Performance Liquid Chromatograph Nexera X2 C196-E79 Maximizing the Potential of UHPLC/HPLC Analyses Intelligence Intelligent data solutions, including a new i -PDeA peak calculation method for

More information

Lipidomic Analysis by UPLC-QTOF MS

Lipidomic Analysis by UPLC-QTOF MS Lipidomic Analysis by UPLC-QTOF MS Version: 1 Edited by: Oliver Fiehn Summary Reagents and Materials Protocol Summary:Lipidomic analysis by UPLC-QTOF mass spectrometry Reagents and Materials: Reagent/Material

More information

Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC

Analysis of Counterfeit Antidiabetic Drugs by UHPLC with the Agilent 1220 Infinity Mobile LC Analysis of Counterfeit Antidiabetic Drugs by UPLC with the Agilent 1 Infinity Mobile LC Application Note Small Molecule Pharmaceuticals & Generics Author Sonja Schneider Agilent Technologies, Inc. Waldbronn,

More information

QuickSplit TM Flow Splitters

QuickSplit TM Flow Splitters Quick TM Flow ters between 2 or more detecrs such as Mass Spectroscopy and evaporative light scattering, UV, or IR. This is especially important when one of the detecrs is destructive, such as Mass Spec

More information

Technical Data Sheet SONOFLOW CO.55 V1.0

Technical Data Sheet SONOFLOW CO.55 V1.0 Technical Data Sheet SONOFLOW CO.55 V1.0 The sensor series SONOFLOW CO.55 V1.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a

More information

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC

Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC Application Note Environmental Author Melanie Metzlaff Agilent Technologies, Inc. Waldbronn, Germany Abstract

More information

HPLC to UHPLC Transfer of USP Method for Amlodipine Besylate Using the Agilent 1290 Infinity II LC

HPLC to UHPLC Transfer of USP Method for Amlodipine Besylate Using the Agilent 1290 Infinity II LC HPLC to UHPLC Transfer of USP Method for Amlodipine Besylate Using the Agilent 129 Infinity II LC Application Note Small Molecule Pharmaceuticals Authors Gerd Vanhoenacker, Mieke Steenbeke, Koen Sandra,

More information

Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2

Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2 Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2 Ordering Information You may contact us via phone, fax, e-mail, or through our website. EPOND S.A. CP 389 CH-1800 Vevey Switzerland Phone:

More information

Purification - Flash Chromatography

Purification - Flash Chromatography SuperFlash Compound Purification Columns Optimal Design Cost effective, high performance disposable flash column specifically designed for flash chromatography. Excellent Separations Designed to deliver

More information

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System

High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System Application Note Food, Hydrocarbon Processing Authors Michael Woodman Agilent Technologies,

More information

injections. Needle Tip 1 µl Cone 1BR

injections. Needle Tip 1 µl Cone 1BR s General Purpose Manual s 0.5-5 µl Nano With the ability to inject down to 50 nl with high precision and accuracy, SGE Nano s are perfect for Nano capillary chromatography injection as well as making

More information

HPLC Analysis with Fluorescence Detection of Chlorophyll Degradation Products Pheophytins and Pyropheophytin in Virgin Olive Oil

HPLC Analysis with Fluorescence Detection of Chlorophyll Degradation Products Pheophytins and Pyropheophytin in Virgin Olive Oil HPLC Analysis with Fluorescence Detection of Chlorophyll Degradation Products Pheophytins and Pyropheophytin in Virgin Olive Oil Application Note Authors Xueqi Li, Selina Wang UC Davis Olive Center Robert

More information

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit

Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit Rapid Gradient and Elevated Temperature UHPLC of Flavonoids in Citrus Fruit Application Note General Chromatography, Food Industry Authors John W. Henderson Jr., Judy Berry, Anne Mack, William Long Agilent

More information

Online 2D-LC Analysis of Complex N-Glycans in Biopharmaceuticals Using the Agilent 1290 Infinity 2D-LC Solution

Online 2D-LC Analysis of Complex N-Glycans in Biopharmaceuticals Using the Agilent 1290 Infinity 2D-LC Solution Online D-LC Analysis of Complex N-Glycans in Biopharmaceuticals Using the Agilent 19 Infinity D-LC Solution Comprehensive and Multiple Heart-Cutting D-LC Analysis for Highest Resolution Application Note

More information

autosamplers ASI-100 and ASI-100T Autosamplers

autosamplers ASI-100 and ASI-100T Autosamplers autosamplers ASI-100 and ASI-100T Autosamplers The ASI-100 and ASI-100T Automated Sample Injectors are highly flexible autosamplers for automating high performance liquid chromatography (HPLC) methods.

More information

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis Product # LS-R1-4.6x150 Ludger Document # LS-R1-DMB-Guide-v5.1 Ludger Ltd Culham Science Centre Oxford OX14 3EB United

More information

Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222

Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222 Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222 Joan Stevens, Ph.D.; Luke Roenneburg; Tim Hegeman; Kevin Fawcett

More information

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager Quick Start Guide Step 1. Calibrate the Q-TOF LC/MS for low m/z ratios 2 Step 2. Set up a Flow Injection Analysis (FIA) method for

More information

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column

LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column Application Note Clinical Research LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell EC C8 Column Authors Rongjie Fu and Zhiming Zhang Agilent Technologies

More information

Application Note. Preparative Isolation of Piperine from Black Pepper Extracts. Summary. Introduction. Fig. 1

Application Note. Preparative Isolation of Piperine from Black Pepper Extracts. Summary. Introduction. Fig. 1 Application Note Preparative Isolation of Piperine from Black Pepper Extracts Category Food analysis Matrix Pepper Extract Method analytical HPLC, preparative HPLC Keywords Pepper, quality control, purity

More information

Am I getting the very best value from my UHPLC analyses?

Am I getting the very best value from my UHPLC analyses? Am I getting the very best value from my UHPLC analyses? Stephen Luke LC Columns Product Manager 1 Primary reasons for UHPLC use Very fast Very high resolution Column 2.1 x 50 mm Column 2.1 x 150 mm Run

More information

Analysis of Vitamins Using an SFC/UHPLC Hybrid System with a Triple Quadrupole LC/MS for Quantification

Analysis of Vitamins Using an SFC/UHPLC Hybrid System with a Triple Quadrupole LC/MS for Quantification Application ote Food Testing and Agriculture Analysis of Vitamins Using an SF/UPL ybrid System with a Triple Quadrupole L/MS for Quantification ounts 4.6.4...8.6.4....4.6.8...4.6.8 Acquisition time (min

More information

Analysis of bisphenol A leaching from baby feeding bottles

Analysis of bisphenol A leaching from baby feeding bottles Agilent Application Solution Analysis of bisphenol A leaching from baby feeding bottles Application Note Consumer Products Author Syed Salman Lateef Agilent Technologies, Inc. Bangalore, India Abstract

More information

JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA

JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA JEFFERSON Cabinet Style Transformers Three-Phase 15 to 1000 KVA TYPICAL APPLICATIONS All general loads, indoors or outdoors, including lighting, industrial & commercial Schools Hospitals Factories Office

More information

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System Keywords Introduction Application Note PHA0413 High Pressure Liquid Chromatography

More information

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology

APPLICATIONS TN Overview of Kinetex 2.6 µm Core-Shell Technology Determination of Impurities and Related Substances for Acetylsalicylic Acid (Ph. Eur. Monograph 9): Increased Sensitivity and Resolution, Faster Analysis, and Reduced Solvent Usage Using Kinetex 2.6 µm

More information

HPLC. Varian Dynamax Preparative HPLC Columns

HPLC. Varian Dynamax Preparative HPLC Columns HPLC Varian Dynamax Preparative HPLC Columns Preparative HPLC Simple, successful and economical Linear scale-up move from analytical separation to preparative purification quickly and simply. Dynamic Axial

More information

Parts and Consumables. Sciclone ALH 3000 and Zephyr Liquid Handlers

Parts and Consumables. Sciclone ALH 3000 and Zephyr Liquid Handlers Parts and Consumables Sciclone ALH 3000 and Zephyr Liquid Handlers 2006 DISPOSABLE TIPS 3 ARRAYS 7 CONSUMABLE POSITIONING 8 ON-DECK ACCESSORIES 10 TEMPERATURE CONTROLLED LOCATORS 12 WASHING STATIONS 13

More information

Purification - Flash Chromatography

Purification - Flash Chromatography SuperFlash Compound Purification Columns Optimal Design Cost effective, high performance disposable flash column specifically designed for flash chromatography. Excellent Separations Designed to deliver

More information

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer A Robustness Study for the Agilent 7 LC-MS/MS Mass Spectrometer Application Note Clinical Research Authors Linda Côté, Siji Joseph, Sreelakshmy Menon, and Kevin McCann Agilent Technologies, Inc. Abstract

More information

Edgar Naegele. Abstract

Edgar Naegele. Abstract Simultaneous determination of metabolic stability and identification of buspirone metabolites using multiple column fast LC/TOF mass spectrometry Application ote Edgar aegele Abstract A recent trend in

More information

Application Note. Authors. Abstract. Petrochemical

Application Note. Authors. Abstract. Petrochemical Fast screening of impurities in biodiesel using the Agilent 160 Infinity Analytical SFC System in combination with evaporative light scattering detection Application Note Petrochemical Authors Maria Rambla-Alegre,

More information

With extended functionality the sensors are also applicable for the detection of air bubbles.

With extended functionality the sensors are also applicable for the detection of air bubbles. Technical Data Sheet The sensor series designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a few milliseconds. With extended functionality

More information

Fig.1. Denatonium benzoate (DB) chemical structure

Fig.1. Denatonium benzoate (DB) chemical structure ILIADE code 280 CLEN Method Determination of Denatonium Benzoate in Alcoholic Products by HPLC-UV 1 Scope The purpose of this method is verification of fulfilment of the legislative requirements on denatured

More information

cataleg-inl-2007-def6.indd /01/ :27:30

cataleg-inl-2007-def6.indd /01/ :27:30 140 cataleg-inl-2007-def6.indd 140 30/01/2009 17:27:30 Index Syringes Hamilton Syringes Content Page Content Page Hamilton General Information 142 Hamilton Syringes 143-146 700 Series MICROLITER Syringes

More information

By: Stephanie Bendtsen, Joseph Calderan, and Celeste Dupont Team 17 Client: Dr. Sun

By: Stephanie Bendtsen, Joseph Calderan, and Celeste Dupont Team 17 Client: Dr. Sun By: Stephanie Bendtsen, Joseph Calderan, and Celeste Dupont Team 17 Client: Dr. Sun Flow Loop Design Introduction Purpose: to build a pulsatile flow loop that allows for implementation and testing of mechanical

More information

Gas Chromatography Syringe Selection Guide

Gas Chromatography Syringe Selection Guide Gas Chromatography Syringe Selection Guide Peter Morgan, Fisher, Runcorn, Cheshire, UK Technical Note 20552 Key Words Syringe selection Abstract Choosing the correct syringe from the wide selection available

More information

Extended Application Note

Extended Application Note Extended Application Note Comparison of 4 μm vs. 2.o Columns in Analysis of Drospirenone/Ethinyl Estradiol Tablet APP A-339 www.mtc-usa.com 1-732-578-1777 INTRODUCTION The formulation of drospirenone and

More information

Hamilton Syringes. LT N LTN RN TLL TLL with slots. Hamilton Syringe Types Microliter. Hamilton Point Styles

Hamilton Syringes. LT N LTN RN TLL TLL with slots. Hamilton Syringe Types Microliter. Hamilton Point Styles Hamilton LT N LTN RN TLL TLL with slots Hamilton Point Styles Pt. 2 Pt. 3 Pt. 5 Pt. HP Hamilton syringes are designed as precision measuring instruments, and find wide use for sample introduction into

More information

ELEMENT 2/ ELEMENT XR Consumables and Parts Catalog

ELEMENT 2/ ELEMENT XR Consumables and Parts Catalog ELEMENT 2/ ELEMENT XR Consumables and Parts Catalog Revision B - 2 470 Analyze Detect Measure Control 2007 Thermo Fisher Scientific. All rights reserved. Viton is a registered trademark of DuPont Dow Elastomers.

More information

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I PORTO 2 VENT CPAP OS Operator s Manual 1 2 TABLE of CONTENTS 1. Introduction 3. Operating Instructions 1a. Definitions 3a. Setting the CPAP Level 1b. General Description 3b. Applying the Breathing Circuit

More information

10 mg in 1.4 ml. XTerra MS C 18, 4.6 x 50 mm. Volume injected: Injector Column. Waste. Pump. Pump. Splitter

10 mg in 1.4 ml. XTerra MS C 18, 4.6 x 50 mm. Volume injected: Injector Column. Waste. Pump. Pump. Splitter MILLIGRM SLE PURIFITION INTO SINGLE WELL OF 96-WELL PLTE ecilia. Mazza, Jie Y. avanaugh, Diane M. Diehl, Tom Wheat, Jo-nn Jablonski, Jeffrey R. Mazzeo Waters orporation, Milford, M 1757 Presented at Pittcon,

More information

Doubling the throughput of long chromatographic methods by using a novel Dual LC workflow

Doubling the throughput of long chromatographic methods by using a novel Dual LC workflow APPLICATIN NTE 7601 Doubling the throughput of long chromatographic methods by using a novel Dual LC workflow Authors Sylvia Grosse, Mauro De Pra, Frank Steiner Thermo Fisher Scientific, Germering, Germany

More information

Application Note. Purification of ω-3-fatty acids from fish oil using MCSGP. Summary. Countercurrent chromatography, multicolumn.

Application Note. Purification of ω-3-fatty acids from fish oil using MCSGP. Summary. Countercurrent chromatography, multicolumn. Application Note Purification of ω-3-fatty acids from fish oil using MCSGP Category Matrix Method Keywords Analytes ID Countercurrent chromatography, multicolumn HPLC ω -3-fatty acids MCSGP MCSGP, countercurrent

More information

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products

Application Note. Authors: C. Ledesma, M. Gibert, J.R. Gibert Ingenieria Analitica S.L. Extracts from various food products High-Performance Anion-Exchange Chromatography coupled with Pulsed Electrochemical Detection as a powerful tool to evaluate lactose content in lactose-free labeled products Application Note Authors: C.

More information

Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract.

Application Note. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling. Abstract. Agilent Application Solution Analysis of fat-soluble vitamins from food matrix for nutrition labeling Application Note Food 1 Agilent 12 Infinity 1 Author Siji Joseph Agilent Technologies, Inc. Bangalore,

More information

USP purity analysis of pravastatin sodium using the Agilent 1120 Compact LC

USP purity analysis of pravastatin sodium using the Agilent 1120 Compact LC USP purity analysis of pravastatin sodium using the Agilent 1120 Compact LC Application Note Manufacturing QA/QC Authors Syed S. Lateef, Siji Joseph Agilent Technologies Bangalore, India 500 400 Pravastatin

More information

Continuation of Reversed-Phase HPLC Analysis Studies of Steviol Glycosides Isolated From Stevia rebaudiana Bertoni

Continuation of Reversed-Phase HPLC Analysis Studies of Steviol Glycosides Isolated From Stevia rebaudiana Bertoni Journal of Food Research; Vol. 4, No. 2; 2015 ISSN 1927-0887 E-ISSN 1927-0895 Published by Canadian Center of Science and Education Continuation of Reversed-Phase HPLC Analysis Studies of Steviol Glycosides

More information

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer HI 903 Karl Fischer Volumetric Titrator Measures 100 ppm to 100% water content Precision titrant delivery system 40,000 step, piston dosing pump Accurate to 0.1% Delivers as little as 0.125 µl of titrant

More information

SUN VALLEY STOVE COMPANY

SUN VALLEY STOVE COMPANY LO HI ON PILOT LO HI ON PILOT SUN VALLEY STOVE COMPANY VENT-FREE NATURAL GAS STOVE HEATER ILLUSTRATED PARTS BREAKDOWN MSVFBNR 1 2 6 21 3 7 4 21 11 22 9 12 23 10 13 OFF 1 17 24 14 16 17 1 19 OFF 12 OWNER

More information

SUPERCRITICAL FLUID EXTRACTION OF TETRAHYDROCANNABINOL FROM MARIHUANA. DETERMINATION OF TETRAHYDROCANNABINOL AND TETRAHYDROCANNABINOL ACID

SUPERCRITICAL FLUID EXTRACTION OF TETRAHYDROCANNABINOL FROM MARIHUANA. DETERMINATION OF TETRAHYDROCANNABINOL AND TETRAHYDROCANNABINOL ACID SUPERCRITICAL FLUID EXTRACTION OF TETRAHYDROCANNABINOL FROM MARIHUANA. DETERMINATION OF TETRAHYDROCANNABINOL AND TETRAHYDROCANNABINOL ACID Lél EÖRY 1, Vera SZALAY 1, Tibor VERESS 2 1 Eötvös L. University,

More information

Independent Column Temperature Control Using an LTM Oven Module for Improved Multidimensional Separation of Chiral Compounds

Independent Column Temperature Control Using an LTM Oven Module for Improved Multidimensional Separation of Chiral Compounds Independent Column Temperature Control Using an LTM Oven Module for Improved Multidimensional Separation of Chiral Compounds Application Note Food and Flavors Author Frank David Research Institute for

More information

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0

Technical Data Sheet SONOFLOW CO.55/xxx(H) V2.0 The sensor series SONOFLOW CO.55/xxx V2.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a few milliseconds. For applications on

More information

Agilent 7700x ICP-MS

Agilent 7700x ICP-MS Agilent 7700x ICP-MS Metals analysis Mid ppt to low ppb detection range Option to detect in four different gas modes to gain optimum detection of multiple metals or interferences in a sample Autosampler

More information

Instrument Assembly Quick Guide

Instrument Assembly Quick Guide Instrument ssembly Quick Guide assembly_qg_br.0, 07/8 08 shcroft Inc. assembly_qg_br.0, Rev., 06/8 info@.800.38.858 ssembly Resource ssembly Information LL SHROFT SSEMLIES RE DESIGNED Y OUR ENGINEERS TO

More information

Designing an Extractables and Leachables Study

Designing an Extractables and Leachables Study Designing an Extractables and Leachables Study 1 2 Overview Background InformaAon Materials of Construction What addiaves are used? MulAlayer films? PrinAng Inks? Finished Packaging Which surfaces does

More information

Forensic Analysis of Blood Alcohol Concentration

Forensic Analysis of Blood Alcohol Concentration Application Note Forensics Forensic Analysis of Blood Alcohol Concentration Using the Agilent 886 GC with Agilent J&W DB BAC1 UI and Agilent J&W DB-BAC2 UI columns and the Agilent 7697A headspace sampler

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS THANK YOU FOR CHOOSING reo sac THE REVOLUTIONARY REINFORCED RAINWATER STORAGE SYSTEM Before you begin, please take time to review the installation instructions and cross check

More information

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis Product # LS-UR2-2.1x100 Ludger Document # LS-uR2-DMB-Guide-v2.1 Ludger Ltd Culham Science Centre Oxford OX14 3EB United Kingdom

More information

Radnoti Langendorff Constant Pressure Non-Recirculating Pump Driven Isolated Heart System For Mouse EZ

Radnoti Langendorff Constant Pressure Non-Recirculating Pump Driven Isolated Heart System For Mouse EZ Radnoti Langendorff Constant Pressure Non-Recirculating Pump Driven Isolated Heart System For Mouse Radnoti 2006 Description Qty Part # Base only, for 4-bar stand 1 159950-B4 Stabilizer Bar only, for 4-Bar

More information

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS

SAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS 224500 SAFETY SHOWERS AND EYEWASHES PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 013010 Accessibility for People with Disabilities B. Section 115000 Laboratory Equipment

More information

In-Line Accessories. In-Line Pressure Gauges. Pressure Gauges. In-Line Accessories

In-Line Accessories. In-Line Pressure Gauges. Pressure Gauges. In-Line Accessories Pressure Gauges Pressure gauges for monitoring system pressure Hoses and test points for sampling oil and determining ISO cleanliness levels Flanges to connect components Valves for system control In-Line

More information

VENTILATOR PRODUCT ACCESSORIES CATALOG

VENTILATOR PRODUCT ACCESSORIES CATALOG VENTILATOR PRODUCT ACCESSORIES CATALOG Puritan Bennett TM 980 Ventilator Puritan Bennett TM 840 Ventilator PROMOTIONAL MATERIALS FOR USE IN THE U.S. TABLE OF CONTENTS Puritan Bennett 980 Ventilator Accessories...

More information

PROXIMAL TIBIAL PLATE

PROXIMAL TIBIAL PLATE SURGICAL NÁSTROJE TECHNIQUE PRO ARTROSKOPII PROXIMAL INSTRUMENTS TIBIAL FOR PLATE ARTHROSCOPY Proximal Tibial Plate Description of medical device The Proximal Tibial Plate is used in epyphyseal and metaphyseal

More information

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS Application Note Clinical Research Authors Frank David and Bart Tienpont, Research Institute for Chromatography,

More information

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION TABLE OF CONTENTS EDITION 5 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2 - INTRODUCTION 2.1. INTRODUCTION 3 Section 3 - GENERAL 3.1. UNPACKING AND INSTALLATION

More information

AUTOMATED LIQUID HANDLING

AUTOMATED LIQUID HANDLING AUTOMATED LIQUID HANDLING Instrument Syringes R THE MEASURE OF EXCELLENCE TM The Measure of Excellence Automated Instrument Syringes When it comes to precision fluid handling, rely on the leader. We ve

More information

Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection

Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection Application Note Food Testing, Metabolomics, Agricultural Chemistry, Environmental Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with

More information

MICS & FEMORAL CANNULAE

MICS & FEMORAL CANNULAE MICS & FEMORAL CANNULAE Cannulae that can High performance cannulae for direct and femoral cannulation, either in conventional or minimally invasive cardiac surgery 1. Pfeiffer et al. Interactive Cardiovascular

More information

GASTRO-INTESTINAL (ENTERAL)

GASTRO-INTESTINAL (ENTERAL) GASTRO-INTESTINAL (ENTERAL) GASTRO-INTESTINAL (ENTERAL) 127 B A C D Gastrostomy Feeding Tubes & Accessories Tri-Funnel Replacement Gastrostomy Tube Green inflator cuff, sterile. Bard 12 French, 5 cc balloon,

More information