PEEK SS Columns & Guard Columns
|
|
- Jeremy Maxwell
- 5 years ago
- Views:
Transcription
1 PEEK SS Columns & Guard Columns ~ Stainless Steel Analytical Columns ~ PEEK Columns ID 2.1, 4.0, 4.6 & 7.5 mm ~ Jour-Guard Cartridges Stainless Steel or PEEK ~ Stainless Steel End Fittings 1/4 OD Columns ~ Stainless Steel Preparative Columns ~ In-Line Biocompatible Guard Columns ~ One-Piece Column Coupler ~ Column End Plugs Stainless Steel Analytical Columns Jour s 4.6 mm ID stainless steel analytical columns are made of high quality SS316L. The finish of the inner surface is extremely smooth with a maximum of 0.2 µm RA. We prefer for safety reasons (especially when packing columns) the threaded (5/16-24) tubing type with SS end-fitting and SS insert. The insert is on the inside conical shaped in order to provide an equal sample distribution over the 0.5 or 2 µm frit. Frits are made of SS 316L and supplied with a PEEK ring. All connections are female fittings. We also offer 3.0 and 4.0 mm ID columns. Stainless Steel Analytical Columns 4.6 mm ID Length 0.5 µm 2.0 µm 50 mm mm mm mm mm Stainless Steel Analytical Columns 4.0 mm ID
2 Length 0.5 µm 2.0 µm 50 mm mm mm mm mm Length 0.5 µm 2.0 µm 50 mm mm mm mm mm Insert End Fitting Packing Adapter Slurry Reservoir Packing Seal P PEEK Encased SS Frit, 2µm P PEEK Encased SS Frit, 0.5 µm
3 PEEK Columns PEEK Columns 4.6 mm & 4.0 mm ID Today s HPLC and IC applications are more demanding than ever. The limitations of traditional stainless steel pose significant problems for a growing number of important biotechnology and ion chromatography applications. Wetted Surfaces: PEEK and PAT (PEEK Alloyed with Teflon) frits Pressures: Max. 350 bar (5000 psi) continous. During packing Max. 560 bar (8000 psi) PEEK Columns 7.5 mm ID Ideal for Semi-prep Biochromatography. The basic column design is shown in the figure and consists of a length of threaded PEEK tubing and two Peek end fittings with the packed bed held in place by two PAT (PEEK Alloyed with Teflon) frits. Connections are made through PEEK inlet and outlet fittings which accept 1/16 OD tubing and standard fingertight fittings. Max operating pressure 350 bar (5000 psi). Low Protein Binding insures high recovery and accurate quantification Wetted Surfaces: PEEK and PAT (PEEK Alloyed with Teflon) frits Pressure: Up to 350 bar (5000 psi) PEEK Columns 2.1 mm ID We have designed this column for your narrow-bore applications and where only limited amounts of sample are available for analysis. Because 2.1 mm ID columns operate at 1/5th the flow rate of their 4.6 mm counterparts, the same sample mass injected on a 2.1 mm column will produce 5X the detector signal. This greater mass sensitivity provides the same analysis as a 4.6 mm column with only 20% of the sample. Only PEEK and PAT (PEEK Alloyed with Teflon) contact the fluid stream. Wetted Surfaces: PEEK and PAT frits Pressure: Should not be used over 210 bar (3000 psi) 2.1 mm ID PEEK Column Tube PAT Frit PEEK End Fitting PEEK Columns 2.1 mm ID mm x 2.1 mm mm x 2.1 mm mm x 2.1 mm mm x 2.1 mm mm x 2.1 mm mm x 2.1 mm PAT Frit End Fitting
4 65216 Packing Adapter Packing Seal PEEK End Fitting PAT Frit 4.6 mm ID PEEK Column Tube PEEK Columns 4.6 mm ID mm x 4.6 mm mm x 4.6 mm mm x 4.6 mm mm x 4.6 mm mm x 4.6 mm mm x 4.6 mm mm x 4.6 mm PAT Frit PEEK End Fitting Packing Adapter Packing Seal 7.5 mm ID PEEK Column Tube PEEK Frit Spacer PAT Frit PEEK End Fitting PEEK Columns 7.5 mm ID mm x 7.5 mm mm x 7.5 mm mm x 7.5 mm mm x 7.5 mm mm x 7.5 mm
5 mm x 7.5 mm PAT Frit PEEK End Fitting PEEK Frit Spacer Packing Adapter Packing Seal PEEK End Fitting PAT Frit 4.0 mm ID PEEK Column Tube mm x 7.5 mm mm x 7.5 mm mm x 7.5 mm mm x 7.5 mm mm x 7.5 mm mm x 7.5 mm PAT Frit PEEK End Fitting Packing Adapter Packing Seal Jour-Guard Cartridges Stainless Steel or PEEK
6 Jour-Guard Cartridge System is a breakthrough in simplicity, reliability and performance! Packing SS Jour-Guard Cartridge RP/C18-5 µm SS Jour-Guard Cartridge RP/C8-5 µm SS Jour-Guard Cartridge RP/Phenyl-5 µm SS Jour-Guard Cartridge NP/Silica-5 µm PEEK Jour-Guard Cartridge RP/C18-5 µm PEEK Jour-Guard Cartridge RP/C8-5 µm PEEK Jour-Guard Cartridge RP/Phenyl-5 µm PEEK Jour-Guard Cartridge NP/Silica-5 µm Jour-Guard Holder Includes: P/N 25602, Jour One-Piece Column Coupler, Female Type
7 Stainless Steel End Fittings 1/4 OD Columns - Can be delivered with or without distributor plate - Comes complete with 0.5, 2 or 5 µm SS frits - Ready for mounting with a configuration to match most instruments. We produce high quality SS column end fittings for standard 1/4 columns from SS 316L steel. Here is a fitting which is passivated with nitric acid and which features a flow geometry producing optimum distribution of sample and eluant across the surface of the column. The Jour SS end fittings are cleaned with ultrasound and are ready for mounting. Stainless Steel End Fittings 1/4 OD Columns CE CE14-2 CE14-5 Stainless Steel Column End Fitting with 0.5 µm SS Frit Stainless Steel Column End Fitting with 2 µm SS Frit Stainless Steel Column End Fitting with 5 µm SS Frit Back to Peek - SS Columns & Guard Columns Stainless Steel Preparative Columns Jour offers a complete line of empty 20 mm ID (1 OD) preparative columns in a variety of lengths including guard columns. We use a zero void end-cap, which accepts industry standard (10-32) fittings and all columns have threaded ends. This avoids the complicated connections with ferrules and allows easy cleaning and refilling. Jour Stainless Steel 20 mm ID Prep. Columns Length (mm)
8 Untitled Document Page 8 of SS Prep. Column 20 mm ID 50 mm SS Prep. Column 20 mm ID 100 mm SS Prep. Column 20 mm ID 150 mm SS Prep. Column 20 mm ID 250 mm SS Prep. Column 20 mm ID 300 mm SS Prep. Column 20 mm ID 500 mm SS Prep. Column 20 mm ID 1000 mm Accessories for 20 mm ID Prep. Columns 43 Slurry reservoir complete for 20 mm ID (1 OD) columns (light version, 1 m length, 20 mm ID) 44 Slurry reservoir complete for 20 mm ID (1 OD) columns (heavy version, 40 mm ID) 46 SS Replacement Frit 5 µm 47 SS Column to Column Adapter 20 mm (to join two columns or guard columns) 48 SS Guard Column (50 mm) 49 SS End piece 54 SS Plate Teflon encased Poro-Web Frit OD 20 mm Thickness 1.7 mm 2 µm Teflon encased Poro-Web Frit OD 20 mm Thickness 1.7 mm 5 µm Back to Peek - SS Columns & Guard Columns In-Line Biocompatible Guard Column - Biocompatible - Easy to Fill Jour's In-Line PEEK Guard Column System extends the life of your valuable analytical column by trapping contaminants from the sample and mobile phase, thereby preventing loss of retention.
9 Only PEEK and PAT contact the eluant and sample. This system is ideal for use with proteins or other biopolymers that may be contaminated or adsorbed by metal surfaces. Jour Guard Columns are easily dry-packed or slurry packed. Guard columns may be changed in minutes without the use of tools - all connections may be made by hand. In-Line PEEK Guard Column In-Line Guard Column, Includes Long Cartridge Nut Guard Cartridge Insert Guard Cartridge ID 8.00 x 3.00 mm Filter Body Slurry Packing Adapter Back to Peek - SS Columns & Guard Columns One-Piece Column Coupler - Join Column to Column - Join Column to Guard Column - Join Column to Injector or Detector - No Wrenches Required Seals to 350 bar (5000 psi) - Metal-Free PEEK Version Here is a inexpensive way to connect columns without the use of extra tubing to join a column to a guard column or to join a column to the injector. The One-Piece-Column-Coupler is made of PEEK with a knurled handle which replaces wrenches. It is also metal-free, and can sustain a working pressure of 350 bar (5000 psi). One-Piece Column Coupler Color Code Female Type Column Coupler for Columns with Black female ports Waters Type Column Coupler for Waters Columns Red Male Type Column Coupler for Columns with Red + Bushing Male Fittings, Valco Type Column Coupler for Valco Fittings Blue Waters Type Column Coupler to Female ports Black with W & F intials
10 Back to Peek - SS Columns & Guard Columns Column End Plugs Try our column end plugs in fingertight design. One size fits all columns. Easy handling is guaranteed by the additional 5/16" wrench flat, which allows you to loosen the plug in case it should be stuck. The long design and the threading down to the ferrule ensures a safe closing of your valuable column. We have made the entire test: Plug sealing, plug evaporation and of course the drop test. We recommend our Column End Plug. Column End Plugs P/N Color 4071 White 4072 Black 4073 Red 4074 Green 4075 Blue Back to Peek - SS Columns & Guard Columns
PEEK Columns & Guard Columns
INDEX PEEK Columns 103 Packing Devices 104 Column Coupler One-Piece Fingertight 105 In-Line Biocompatible Guard Column 106 Column End Plugs 107 Column End Plugs, Logotype 107 Disclaimer The maximum holding
More informationCalibration Standards
Calibration Standards/ Calibration Standards TSKgel standards polystyrene TSKgel standards poly(ethylene oxide) PStQuick polystyrene calibration standards TSKgel guard column products Fittings Pre-injector
More informationACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity
ACE CN-ES Combining CN polar selectivity with enhanced hydrophobicity Extended Spacer Extra Stability New stationary phase technology for UHPLC and HPLC separations Alternative polar selectivity for method
More informationProtect your expensive HPLC and UHPLC columns from premature failure with MAC-MOD Pre-Column Filters
Protect your expensive HPLC and UHPLC columns from premature failure with MAC-MOD Pre-Column Filters Over 70% of the failures of HPLC columns are caused by inlet frit plugging. MAC-MOD Pre-Column Filters
More informationSecurityGuard. Column Protection for UHPLC, HPLC to PREP. A Universal Guard Cartridge System. Increases HPLC Column Lifetime, Guaranteed!
U.S. Patent No. 6, 162, 362 Column Protection for UHPLC, HPLC to PREP Protect HPLC columns and extend lifetime Virtually no change in chromatography Available in analytical, semi-prep, and preparative
More informationHamilton Syringes. LT N LTN RN TLL TLL with slots. Hamilton Syringe Types Microliter. Hamilton Point Styles
Hamilton LT N LTN RN TLL TLL with slots Hamilton Point Styles Pt. 2 Pt. 3 Pt. 5 Pt. HP Hamilton syringes are designed as precision measuring instruments, and find wide use for sample introduction into
More informationNeedle Gauge. Needle OD (mm) Needle ID (mm)
s LC Manual s Beckman/Altex, Rheodyne, SSI Instruments and Valco Valves s and Borosilicate Glass Barrel Outer Diameter () Scale 5 µl and 10 µl = 6.5 mm, 25 µl to 500 µl = 8 mm, 1 ml = 8.8 mm, 2.5 ml =
More informationautosamplers ASI-100 and ASI-100T Autosamplers
autosamplers ASI-100 and ASI-100T Autosamplers The ASI-100 and ASI-100T Automated Sample Injectors are highly flexible autosamplers for automating high performance liquid chromatography (HPLC) methods.
More informationAdvanced Column Designs and Innovative Packing Procedures
Advanced Column Designs and Innovative Packing Procedures The Perfect Combination for Preparative and Process HPLC Separations 2002 Product Catalog MODcol Yesterday and Today Founded in 1982 by Dr. Yehuda
More informationPurification - Flash Chromatography
SuperFlash Compound Purification Columns Optimal Design Cost effective, high performance disposable flash column specifically designed for flash chromatography. Excellent Separations Designed to deliver
More informationINTEGRAL-BONNET NEEDLE VALVES H-300 SERIES
INTEGRAL-BONNET NEEDLE VALVES SERIES INTEGRAL-BONNET NEEDLE VALVES SERIES FEATURES n Straight and angle pattern n Stainless Steel and Brass construction n MAWP 5000 psi (345 bar) n MAWT 446 F (230 C) n
More informationContents. Coming soon from Teryair!!
Technical products for the ship suppl y industry Contents Teryair is a specialist manufacturer of precision pneumatic tools and marine industrial equipment. Our factories in Mumbai, India are certified
More informationCompressor Accessories
Compressor Accessories Series 11 Superior quality for superior performance COMPRESSOR OIL Description MINERAL 11.1100 1 litre container 11.1400 4 litre container SYNTHETIC 11.1200 1 litre container 11.1500
More informationQuickSplitTM Flow Splitters
QuickTM Flow ters between 2 or more detectors such as Mass Spectroscopy and evaporative light scattering, UV, or IR. This is especially important when one of the detectors is destructive, such as Mass
More informationMEDIUM-FLOW PNEUMOTACH TRANSDUCER
MEDIUM-FLOW PNEUMOTACH TRANSDUCER SS11LA for MP3x and MP45 System TSD117 & TSD117-MRI for MP150/MP100 System RX117 Replacement Airflow Head See also: AFT series of accessories for airflow and gas analysis
More informationHPLC. Varian Dynamax Preparative HPLC Columns
HPLC Varian Dynamax Preparative HPLC Columns Preparative HPLC Simple, successful and economical Linear scale-up move from analytical separation to preparative purification quickly and simply. Dynamic Axial
More informationProduct Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis
Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis Product # LS-R1-4.6x150 Ludger Document # LS-R1-DMB-Guide-v5.1 Ludger Ltd Culham Science Centre Oxford OX14 3EB United
More informationChoosing Preparative Columns
Choosing Preparative Relationship between Column I.D., Sample Loading Volume and Flow Rate In preparative operations, column internal diameter sizes from 6.0 to 100 mm are widely used. When the analytical
More informationBabyBio IMAC columns DATA SHEET DS
BabyBio IMAC columns DATA SHEET DS 45 655 010 BabyBio columns for Immobilized Metal Ion Affinity Chromatography (IMAC) are ready-to-use for quick and easy purification of polyhistidine-tagged (His-tagged)
More informationCheck Valves PRODUCT DESCRIPTION FEATURES & BENEFITS TECHNICAL SPECIFICATIONS
Check Valves PRODUCT DESCRIPTION CPI check valves are designed for high pressure applications where reverse flow and leakage must be kept to a minimum. Typical applications include engine, pump and compressor
More informationinjections. Needle Tip 1 µl Cone 1BR
s General Purpose Manual s 0.5-5 µl Nano With the ability to inject down to 50 nl with high precision and accuracy, SGE Nano s are perfect for Nano capillary chromatography injection as well as making
More informationNeedle Valves. We deliver confidence through quality products
We deliver confidence through quality products INTRODUCTION NEEDLE VALVES SD range of Needle valves come in various sizes, sealing styles, end connections and stem types. They are available in bar stock
More informationTECHNICAL SPECIFICATIONS. Carbon Steel / Stainless Steel One piece design BALL. Stainless Steel MAXIMUM OPERATING TEMPERATURE CRACKING PRESSURE
Check Valves PRODUCT DESCRIPTION CPI check valves are designed for high pressure applications where reverse flow and leakage must be kept to a minimum. Typical applications include engine, pump and compressor
More informationSelection and Optimization of the Sample Introduction System
Selection and Optimization of the Sample Introduction System Geoff Tyler*, Lisa Goldstone, Odile Hirsch* Jobin Yvon, Inc., 3880 Park Avenue, Edison, NJ 08820 * Jobin Yvon SAS, 16-18, rue du Canal, 91165
More informationThermo Finnigan. 6-2 LCQ Advantage Getting Started-
To set up the LCQ Advantage to acquire data in the APCI/MS mode, you do the following:.install the APCI probe assembly.set up to infuse your analyte into the MS detector using a syringe pump connected
More informationBROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / VACUUM
BROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / ACUUM LAB TABLE OF CONTENTS Content Page Table of Content 2 Product Overview 3 BROEN UniFlex TM BASIC 4-5 Fittings for Non-burnig 2.0 Gases/acuum Turret
More informationTHOMAFLUID - Handbook III
Reichelt Chemietechnik GmbH + Co. THOMAFLUID - Handbook III Capillary Connectors Micro Connectors Macro Connectors Pipe Connectors Welding Sleeves Bonded Socket Joints Plug-in Connectors HPLC Connectors
More informationCam & Groove Fittings. King Nipples
Cam & Groove Fittings King Nipples Index Aluminum Type A, Male Adapter x Female NPT...3 Type B, Female Coupler x Male NPT...3 Type C, Female Coupler x Hose Shank...4 Type D, Female Coupler x Female NPT...4
More informationACE HILIC + + UHPLC and HPLC Columns. For Reproducible Polar Analyte Separations. Three HILIC Column Chemistries Available
ACE HILIC UHPLC and HPLC s For Reproducible Polar Analyte Separations Three HILIC Chemistries Available ACE HILIC s What is HILIC? Hydrophilic Interaction Liquid Chromatography (HILIC) was first described
More informationLC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined
ProteCol LC Columns - Exceed the limit A premium inert range of LC columns delivering optimal peak shape. ProteCol -G Glass lined ProteCol -P PEEK lined B C A D E F A Column end cap B PEEK frit housing
More informationChoose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide
Choose for Your Instrument GC Supplies - Shimadzu Instrument Quick Pick Guide Syringes Septa Inlet Liners O-rings and Sealing Rings SilTite FingerTite Ferrules Ferrules Replacement Parts Your chromatography
More informationInfinityLab Purification Capillary Kits
InfinityLab Purification Capillary Kits Technical Note This note describes the capillary connections for Agilent preparative systems. Agilent Technologies Contents Abbreviations 3 List of Modules 4 Overview
More informationProduct Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis
Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis Product # LS-UR2-2.1x100 Ludger Document # LS-uR2-DMB-Guide-v2.1 Ludger Ltd Culham Science Centre Oxford OX14 3EB United Kingdom
More informationMEDICAL GAS FITTINGS & CONNECTIONS Quick Reference Guide
MEDICAL GAS FITTINGS & CONNECTIONS Quick Reference Guide www.baycorporation.com ISO 9001 ISO 13485 Follow us: 867 Canterbury Rd., Westlake, OH 44145 USA P: 440.835.2212 888.835.3800 F: 440.835.1377 E:
More informationInline Filters (F Series) Catalog 4130-F July 2005
Inline Filters (F Series) Catalog 4130-F July 2005 Catalog 4130-F Introduction Parker are designed for protection of instrumentation systems from undesirable materials. Component changes or repair and
More informationNew Zealand s Most Advanced Urinal Technologies
New Zealand s Most Advanced Urinal Technologies Caroma is offering three new, advanced technology urinal options to meet industry needs where water-saving is a vital project requirement. A major breakthrough
More informationHTEC-500 and 700 Series Related
HTEC-500 and 700 Series Related Columns and Reagents 681.407.00 P3-AC -PC Prepacked AC Precolumn (3pcs/pkg) 450.00 3mm 681.406.00 P3-CH-PC Prepacked CH Precolumn (3 pcs/pkg) 450.00 3mm 681.405.00 P3-CA-PC
More informationThe LOCATOR concept. Simplicity and versatility for prosthesis fixation
The concept Simplicity and versatility for prosthesis fixation The concept Experience the freedom in prosthesis fixation Simple and secure fixation of implant-supported prostheses is essential for successful
More informationBONE SUBSTITUTION SPECIAL MEMBRANES SCREWS RIVETS
BONE SUBSTITUTION SPECIAL MEMBRANES SCREWS RIVETS 1 Introduction About the company 2 Technology and quality 3 Applied raw materials 5 BIONIKA Titanium membrane meshes Titanium membranes Special membrane
More informationOverview on YMC Column Hardware and Phases
Overview on and Phases Contents UHPLC Column Hardware PT and CC...page 02 Analytical Column Hardware PTH and WT...page 03 Analytical Column Hardware QT and QC...page 04 Analytical Column Hardware GC...page
More informationSavillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES
Savillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES Summary The Savillex C-Flow 700d (C700d) is a concentric PFA nebulizer designed specifically for ICP-OES, combining extreme matrix
More informationA New Era in SFC Column Technology
B TM A ew Era in SFC Column Technology Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level
More informationQuickSplit TM Flow Splitters
Quick TM Flow ters between 2 or more detecrs such as Mass Spectroscopy and evaporative light scattering, UV, or IR. This is especially important when one of the detecrs is destructive, such as Mass Spec
More informationMisc: Interchange Coupling
Wing Style Interchange Coupling Misc: Interchange Coupling Series: W Interchange: Parker 6100 - Seals: Nitrile - Threaded sleeve allows connection/disconnection under pressure - Coupler: brass material
More informationSavillex Technical Note
Savillex Technical Note C400d PFA Concentric Nebulizer for ICP-MS Summary The Savillex C-Flow 400d (C400d) PFA concentric nebulizer combines the reliability of a low flow glass concentric nebulizer with
More informationPart 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants
Select Part 2 Internal Tri-Channel Connection Replace Select NobelSpeedy Replace NobelReplace and compatible implants listed below Select Part 2 contains only the Tri-Channel Internal Connection compatible
More informationRUBBER WATERBLAST HOSES
up to 15, PSI (1 Bar) RUBBER WATERBLAST HOSES These high pressure hose assemblies combine rugged construction, dependability and safe performance. Designed specifically for waterblast applications Lightweight
More informationOverview on YMC Column Hardware and Phases
Overview on and Phases Content UHPLC Column Hardware PT and CC...page 03 Analytical Column Hardware PTH and WT...page 04 Analytical Column Hardware QT and QC...page 05 Analytical Column Hardware GC...page
More informationP SERIES. 250 psi NFPA Pneumatic Cylinder TECHNICAL BROCHURE. Bore Sizes from 11/2 to 14
Actuation Solutions and Systems for the P SERIES 250 psi NFPA Pneumatic Cylinder Bore Sizes from 11/2 to 14 Actuation Solutions and Systems for the Design & Materials Temperature Ratings Low Temp. -54
More informationROTARY UNION 9000 SERIES GENERAL PURPOSE MODELS ADDED MODELS ADDED. Operating Parameters FEATURES & BENEFITS MEDIA PRESSURE* TEMPERATURE* SPEED*
ROTARY UNION 9 SERIES GENERAL PURPOSE Operating Parameters Steam, Hot Oil, Water MEDIA PRESSURE* 25 psi (Water), 75 psi (Steam), psi (Hot Oil) MODELS ADDED MODELS ADDED TEMPERATURE* 6 F (Hot Oil), 378
More informationCarnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual
Page 1 / 14 Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual ZV-3051-0200-15 200 Page 2 / 14 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. TEST
More informationcomponents IC, PB PSCK Pressure switches Digital pressure gauges Pressure gauges GA, GS NV, FM Gauge accessories A, AH/R HLS, H, T
Pressure switches t series IC, PB PSCK t page 188 Digital pressure gauges DG 189 Pressure gauges Gauge accessories Manifolds, couplers, hoses, tubing G GA, GS NV, FM A, AH/R HLS, H, T 190 191 192 High
More informationElemental Scientific Semiconductor Catalog for Thermo ELEMENT2
Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2 Ordering Information You may contact us via phone, fax, e-mail, or through our website. EPOND S.A. CP 389 CH-1800 Vevey Switzerland Phone:
More informationPetite Wound Drainage System. 13mm CWV Drainage System. CWSump. CWV with Trocar
CWVDrain Designed to assure optimum cosmetic results Tapered, hubless design provides atraumatic insertion and removal Internal ribs prevent collapsing or kinking Large 150cc capacity reservoir decreases
More informationProduct Guide for LudgerSep TM R1 HPLC Column for Glycan Analysis
Product Guide for LudgerSep TM R1 HPLC Column for Glycan Analysis (Ludger Product Code: LS-R1-4.6x150) Ludger Ltd Culham Science Centre Oxford OX14 3EB United Kingdom Tel: +44 1865 408 554 Fax: +44 870
More informationSavillex Technical Note
Savillex Technical Note C700d PFA Concentric Nebulizer for ICP-OES Summary The Savillex C-Flow 700d (C700d) is a concentric PFA nebulizer designed specifically for ICP-OES, combining extreme matrix tolerance
More informationMore accurate results.
More choices. More productivity. More accurate results. Agilent's Complete Line of Autosampler and Manual Syringes Specifications and Selection Guide Table of Contents Introduction to Agilent Syringes...2
More informationCANNABIS TESTING ACCESSORIES
CANNABIS TESTING ACCESSORIES HPLC/GC/Sample Prep www.phenomenex.com/cannabis Popular Accessories for Cannabis Testing Cannabis Testing Accessories Sample Preparation Vials Sample Preparation Phenex Syringe
More informationTru-Fit 10k Fittings
Tru-Fit 10k Fittings TruFit 10K Pipe and Adapter Fittings are designed and manufactured to provide a reliable connection in high pressure systems running to 10,000 psi. Manufactured from fully-traceable
More informationNeedle Valves Catalog 4110-NV December 2010
Needle Valves Catalog 4110-NV December 2010 Series Needle Valves Catalog 4110-NV Introduction Parker Series nion onnet Valves have been engineered for use at pressures up to 6,000 (414 bar) and temperatures
More informationICP-OES Organics Kit Installation Instructions
The ICP Organics Kit is an accessory for use with the Agilent ICP-OES instruments. It is available in two versions one for axial ICP-OES and the other for radial ICP-OES. It is used to analyze directly
More informationPremium Chemical Free Iron/Sulphur Filter Installation Manual
Premium Chemical Free Iron/Sulphur Filter Installation Manual 220 Bayview Avenue Unit 18 Barrie, Ontario, Canada, L4N 4Y8 www.excaliburwater.com EXCALIBUR PREMIUM CHEMICAL FREE IRON/SULPHUR FILTER INSTALLATION
More informationQuick Sealing with a Twist to Connect Actuation Method
- Finger tighten seals up to 689 bar (10,000 psi) for pneumatic and hydraulic testing - Safe and Reliable leak tight connections to male and female threads - Eliminate thread damage, sealant and wrenches
More informationAeris. Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations. Aeris PEPTIDE. Aeris WIDEPORE
Aeris Precision Engineered Core- Shell Particles for Ultra-High Resolution BioSeparations Aeris is a specialized line of reversed phase core-shell UHPLC columns, built exclusively for the ultra-high performance
More informationChromatogram Search Tool Search by compound name, synonym, CAS # or keyword Pinnacle II Columns
: 3μm or 5μm particles; 110Å pore size Silica at, for total control of quality and reproducibility. Excellent replacement for the original Hypersil material. Physical and chromatographic properties similar
More informationExtraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis
Application Note AN784 Extraction of Multiple Mycotoxins from Nuts Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis This application note
More informationSolutions for Liquid Handling
221 INDEX Filter Barrier Tips 222 Barrier-ESP Tips & Non-Filter Tips (Racked) 224 Non-Filter ESP Tips 224 ESP Reloading System 225 Empty Trays & Racks 226 Microcentrifuge Tubes 227 Screw Cap Tubes 228
More informationEnvironmental Submersible Pumps
Environmental Submersible Pumps Grundfos 85S Enviro Retrofitted Submersible Pumps These Grundfos submersible pumps are made of stainless steel and retrofitted with PTFE to handle the rigors of contaminated
More informationAgilent Technologies Prep LC Columns
Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies has always taken seriously its responsibility to ensure your success. That s why all our instruments and supplies
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS THANK YOU FOR CHOOSING reo sac THE REVOLUTIONARY REINFORCED RAINWATER STORAGE SYSTEM Before you begin, please take time to review the installation instructions and cross check
More informationRATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG A company of the KLINGEL GROUP
RATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG 0 A company of the KLINGEL GROUP Contents Universal ratchet without torque function General information All ratchets are available with different
More informationSample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results
Sample Preparation Techniques for Biological Matrices: Finding the right balance to achieve optimal results Presenter: Diana Wang Applications Engineer SPP-Support@agilent.com 1 Today s Agenda - Why sample
More informationEnvironmental Submersible Pumps
Environmental Submersible Pumps Grundfos 300S Enviro Retrofitted Submersible Pumps These Grundfos submersible pumps are made of stainless steel and retrofitted with PTFE to handle the rigors of contaminated
More informationYMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability
YMC-Actus Columns for Semi-preparative HPLC Selectivity Durability Loadability Fast semi-preparative chromatography Semi-preparative chromatography is the link between analytical HPLC and preparative LC.
More informationFITTINGS. Pneufit C composite and Pneufit M fittings Inch Ø 1/8" to 1/2" O/D tube
Pneufit C composite and Pneufit M fittings Ø 1/8" to 1/2" Ready to use. Over 1,000 composite push-in pneumatic fittings. Releasable stainless-steel grab-ring to grip nylon or polyurethane (8 or 9 durometer).
More informationColumns for HPLC. Columns for HPLC
Basic principles of preparative HPLC Basically, preparative HPLC follows the same rules as analytical scale chromatography. However, there are important differences in the aims of the two techniques. In
More informationCaleva tablet dissolution baths normally use cannula style filters with a large range of porosities. 100 Pack 1000 Case. 100 Pack 1000 Case
Filters Caleva Compatible Cannula Filters Caleva tablet dissolution baths normally use cannula style filters with a large range of porosities. PSFIL001-CA-100 PSFIL001-CA-1000 0810100 0810101 PSFIL004-CA-100
More informationCOST, PROCESS & QUALITY IMPROVEMENT
COST, PROCESS & QUALITY IMPROVEMENT - Finger tighten seals up to 10,000 psi (689 bar) for pneumatic and hydraulic testing - Safe and Reliable leak tight connections to male and female threads - Eliminate
More informationImpact resistant PBT body in black for Pneufit C and light gray for Pneufit M.
Pneufit C composite and Pneufit M fittings Ø Â" to Ë" Ready to use. Over 1,000 composite push-in pneumatic fittings. Releasable stainless-steel grab-ring to grip nylon or polyurethane (85 or 95 durometer).
More informationEnvironmental Submersible Pumps
Environmental Submersible Pumps Grundfos 230S Enviro Retrofitted Submersible Pumps These Grundfos submersible pumps are made of stainless steel and retrofitted with PTFE to handle the rigors of contaminated
More informationForensic Analysis of Blood Alcohol Concentration
Application Note Forensics Forensic Analysis of Blood Alcohol Concentration Using the Agilent 886 GC with Agilent J&W DB BAC1 UI and Agilent J&W DB-BAC2 UI columns and the Agilent 7697A headspace sampler
More informationACE. For increased polar retention and alternative selectivity. Alternative selectivity for method development
ACE C8-Amide For increased polar retention and alternative selectivity Alternative selectivity for method development Improved separations with polar, acidic, basic and phenolic compounds High efficiency
More informationProduct Index by Coupler Style & Interchange
Product Index by Coupler Style & Interchange Flat Face Style Series Description Page # A Premier ISO 16028 Interchange Flat Face Coupling In accordance with ISO 16028 for Interchange and Performance. s:
More informationVitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid
Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Application Note Clinical Research Authors Derick Lucas and Limian Zhao Agilent Technologies, Inc. Abstract Lipids from
More informationInstructions for Use. IJ Catheter Ultrasound Model Version 2400 Series
Instructions for Use IJ Catheter Ultrasound Model Version 2400 Series 3601 Sagamore Parkway North, Suite B Lafayette, IN 47904 Phone 765.742.4813 www.hemocleanse.com Instructions Revision 3.0 2014 Table
More informationFujiCEM 2. Superior resin-modified glass. Force and Fusion technology. from GC. NEW SLIDE & LOCK system. ionomer luting cement with our innovative
NEW SLIDE & LOCK system FujiCEM 2 from GC Superior resin-modified glass ionomer luting cement with our innovative Force and Fusion technology for your total peace of mind. Take the next step in the dental
More informationToday s Improved Compressed Air Piping Method
STEP 1 STEP 2 STEP 3 (see page 8 for detailed instructions) Today s Improved Compressed Air Piping Method FAST INSTALLATION TIME -Aluminum piping is easy to cut and lift -O-ring seals ensure a leak free
More informationPerformance of an ultra low elution volume 96-well plate
Performance of an ultra low elution volume 96-well plate Claude R. Mallet, Ziling Lu, Jeff R. Mazzeo, Uwe D. Neue Waters Corporation PittCon 2003 March 10-14 2003 Orlando, Florida Today s Challenges Faced
More informationRadnoti Langendorff Constant Pressure Non-Recirculating Pump Driven Isolated Heart System For Mouse EZ
Radnoti Langendorff Constant Pressure Non-Recirculating Pump Driven Isolated Heart System For Mouse Radnoti 2006 Description Qty Part # Base only, for 4-bar stand 1 159950-B4 Stabilizer Bar only, for 4-Bar
More informationSS11LA Pneumotach Transducer
BIOPAC Systems, Inc. 42 Aero Camino Goleta, CA 93117 Ph (805) 685-0066 Fax (805) 685-0067 www.biopac.com info@biopac.com SS11LA Pneumotach Transducer The SS11LA can be used to measure respiratory flow
More informationProduct Guide for LudgerSep TM C3 anion exchange HPLC Column for Glycan Analysis
Product Guide for LudgerSep TM C3 anion exchange HPLC Column for Glycan Analysis (Ludger Product Code: LS-C3-7.5x75) Ludger Document # LS-C3-Guide-v3.0 Ludger Ltd Culham Science Centre Oxford OX14 3EB
More informationProduct Guide. MSP Corporation Rice Creek Parkway, Suite 300. Shoreview, Minnesota 55126, U.S.A. Phone: Fax:
Product Guide inhalertesting MSP Corporation 5910 Rice Creek Parkway, Suite 300 Shoreview, Minnesota 55126, U.S.A. Phone: 651.287.8100 Fax: 651.287.8140 sales@mspcorp.com www.mspcorp.com About This Guide
More information15K CATALOG. 15K psi Water Blasting Parts and Accessories. Accessories. Control Guns. Fittings. Rigid Lances. Flex Lances. Hoses. Nozzles.
2015 CATALOG Always Providing Service 15K psi Water Blasting Parts and Accessories Accessories Calder Ltd Prescott Drive Warndon Worcester WR4 9NE United Kingdom Control Guns web: email: tel: fax: www.calderltd.com
More informationUnion Bonnet Valves - VU6 Series
BlowOur Proof Back Seating Hardened Stem Thread Mountable Panel nut Metal Seal Bonnet Union Bonnet Valves VU6 Series Features Pressure rating up to 6000psig (13bar) @38 C (100 F) Temperature rating from
More informationBMI Medical. Ventricular Catheter T
Shunting System Ventricular Catheter 01101 01101T Barium-impregnated silicone catheter provides resistance to kinking and compression. Stainless steel stylet allows catheter to be directed during catheter
More informationDiagnosis 220 Temporary Filling Carrier. Periodontics Periodontal Curette / Sharpener
Diagnosis 220 Temporary Filling Carrier Periodontics Periodontal Curette / Sharpener Conservative Treatment Composite Syringe / Rubber Dam Punch / Clamp Forceps / Rubber Dam Kit / Reamer Stand / Endodontic
More informationTEKNOCRAFT INC. Proportional Valves. Mini Valves. Outlet Balanced Valves. Standard Valves. Your Proportional Valve Specialists
TEKNOCRAFT INC. Your Proportional Valve Specialists Proportional Valves Mini Valves Outlet Balanced Valves Standard Valves Table of Contents Teknocraft Unique Designs... 3 Mini Valves... 6 Outlet Balanced
More informationAm I getting the very best value from my UHPLC analyses?
Am I getting the very best value from my UHPLC analyses? Stephen Luke LC Columns Product Manager 1 Primary reasons for UHPLC use Very fast Very high resolution Column 2.1 x 50 mm Column 2.1 x 150 mm Run
More informationHypersil BDS and Hypersil Classical HPLC Columns
LC Columns and Accessories Hypersil BDS and Hypersil Classical HPLC Columns Exceptionally reliable and reproducible general purpose columns Exceptionally reliable robust columns that guarantee you have
More information