Review Article Echocardiographic Assessment of Preload Responsiveness in Critically Ill Patients

Size: px
Start display at page:

Download "Review Article Echocardiographic Assessment of Preload Responsiveness in Critically Ill Patients"

Transcription

1 Cardiology Research and Practice Volume 2012, Article ID , 7 pages doi: /2012/ Review Article Echocardiographic Assessment of Preload Responsiveness in Critically Ill Patients Alexander Levitov and Paul E. Marik Division of Pulmonary and Critical Care Medicine, Eastern Virginia Medical School, Norfolk, VA 23507, USA Correspondence should be addressed to Alexander Levitov, levitoab@evms.edu Received 11 April 2011; Revised 28 May 2011; Accepted 8 June 2011 Academic Editor: Antoine Vieillard-Baron Copyright 2012 A. Levitov and P. E. Marik. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. Fluid challenges are considered the cornerstone of resuscitation in critically ill patients. However, clinical studies have demonstrated that only about 50% of hemodynamically unstable patients are volume responsive. Furthermore, increasing evidence suggests that excess fluid resuscitation is associated with increased mortality. It therefore becomes vital to assess a patient s fluid responsiveness prior to embarking on fluid loading. Static pressure (CVP, PAOP) and echocardiographic (IVC diameter, LVEDA) parameters fails to predict volume responsiveness. However, a number of dynamic echocardiographic parameters which are based on changes in vena-caval dimensions or cardiac function induce by positive pressure ventilation or passive leg raising appear to be highly predictive of volume responsiveness. 1. Introduction Shock (hemodynamic failure) is ubiquitous in the modern intensive care unit (ICU). Venodilation, transudation of fluid from the vascular space into the interstitium and increased insensible losses result in hypovolemia early in the course of patients with sepsis. Early goal-directed therapy (EGDT) emphasizes aggressive fluid resuscitation of septic patients during the initial 6 hours of presentation [1]. Persistent hypotension after initial fluid resuscitation is common and poses the dilemma of whether the patient should receive additional fluid boluses or a vasopressor agent should be initiated. Persistent signs of organ hypoperfusion such as oliguria make this decision crucial. While number of technologies including pulse counter analysis [2], transpulmonary thermodilution [3] and bioreactance[4] have all shown promise in evaluation of volume status of septic patients, bedside ultrasonography has already established itself as useful technique to evaluate cardiac function [5]. Applying the same echocardiographic techniques to dynamically assess the physiological response to spontaneous or mechanical ventilation, bedside maneuvers and the response to therapeutic interventions will likely become a cornerstone of hemodynamic monitoring in the modern ICU. 2. Benefits and Pitfalls of Fluid Resuscitation When hypovolemia (either absolute or relative) is suspected, fluid resuscitation will provide benefit to the patient by increasing venous return, cardiac output, arterial blood pressure and ultimately tissue perfusion. The rapidity, with which euvolemia is reestablished may be a decisive factor in the eventual outcome [1]. That being said, there is an increasing body of evidence suggesting that fluid resuscitation is not without serious and possibly lethal complications. Those complications may be related to preexisting conditions such as systolic or diastolic heart failure, cor pulmonale, or the development of sepsis-related cardiac dysfunction [6]. Extravasation of fluids may result in worsening of acute respiratory distress syndrome (ARDS) and prolonged mechanical ventilation [7]. Anemia and clotting disorders occur with hemodilution. Excessive fluid resuscitation can be positively correlated with increased mortality in the ICU [8 10]. Given the risk to benefit ratio of volume expansion, the key question is whether the patient would benefit from additional fluid boluses. It is essential to make this determination as clinical studies have repeatedly demonstrated that only about 50% of hemodynamically unstable ICU patients are volume responsive (see definitions below).

2 2 Cardiology Research and Practice 3. Fluid Challenge versus Volume Responsiveness Previously this question was answered by administering a fluid challenge of 30 ml/kg of crystalloid solution, and the patients clinical (blood pressure, heart rate, urine output) and hemodynamic response (CVP, PAOP) to the challenge was evaluated. Importantly, because a fluid challenge has to be given to assess volume responsiveness, and hypervolemia is associated with significant complications, one would suggest that the increase in mortality associated with invasive hemodynamic monitoring [11] may be attributed to this approach. Therefore, given the increased mortality associated with excessive fluid resuscitation it seems prudent to be able to predict the response to a fluid bolus prior to administering the bolus; a concept known as volume responsiveness. The standard definition of volume responsiveness is a >15% increase in cardiac output in response to volume expansion. Although the volume of the fluid bolus has not been well standardized, a volume of between 500 ml to 1000 ml of crystalloid solution has been most studied. One or more baseline hemodynamic parameters are measured and evaluated for the ability to discriminate between responders and nonresponders. 4. Static Parameters A static parameter is measured under a single ventricular loading condition and is presumed to reliably estimate the preload of the right ventricle (RV), left ventricle (LV), or both ventricles. This estimation is used to evaluate the probability of responsiveness to ventricular filling, by assuming that a lower preload increases the probability of a response to volume expansion. Several static parameters of ventricular preload have been used in the ICU; some are based on direct pressure measurements, while others use echocardiographic indices Static Pressure Parameters. The traditional approach to fluid resuscitation consists of measuring a pressure parameter such as the central venous pressure (CVP) or pulmonary artery occlusion pressure (POAP) together with a cardiac output determination. The clinician would then prescribe a fluid challenge and reassess the above mentioned parameters. This approach has been largely discredited by the data suggesting a poor or no correlation between the CVP or PAOP and volume responsiveness as well as intravascular volume [12]. Nevertheless, the vast majority of intensivists still utilize the CVP to assess volume status [13] and the major critical care societies advocate for CVP as a measure of successful fluid resuscitation [14]. Several studies have demonstrated that the response to a fluid challenge even in healthy volunteers cannot be predicted by either the CVP or PAOP. In a study by Kumar et al. [15] in healthy subjects, static indices of ventricular preload (CVP,PAOP, LVEDV index, and RVEDV index) and cardiac performance indices (cardiac index, stroke volume index) were measured before and after 3 liters of normal saline loading. In this study, there was no correlation between baseline static pressure parameters and changes in the cardiac performance indices (cardiac index and stroke volume index) after fluid loading. Similarly, there was no correlation between changes in the CVP and PAOP and changes in cardiac performance [16]. A meta-analysis by Coudray et al. [17] reviewed five studies on a mixed population of spontaneously breathing critically ill patients and demonstrated the absence of a correlation between the initial PAOP and the response to a crystalloid infusion (an average of 1 liter) Static Echocardiographic Parameters. As echocardiography is noninvasive, it has advantages over pressure-derived parameters particular those obtained from pulmonary artery catheterization. Transthoracic echocardiography (TTE) is preferred; however, in certain circumstance transesophageal echocardiography (TEE) may be required. The CVP and PAOP (left atrial pressure) can be approximated by echocardiography. In spontaneously breathing patients, there is a fairly good correlation between the size of the IVC and the CVP. However, Feissel et al. demonstrated that the absolute IVC size failed to predict fluid responsiveness in patients with septic shock [18]. PAOP (left atrial pressure) estimates involve the use of Doppler mitral flow E/A ratio, pulmonary venous flow, tissue Doppler (E/Ea ratio), or colored coded Doppler (E/Vp ratio). While beyond the expertise level of most American intensivists, the estimated left atrial pressure can be estimated as part of a comprehensive echocardiographic examination performed by an experienced operator. However, it is worth noting that the PAOP fails to predict volume responsiveness whether measured directly or by echocardiography. The RV and LV diastolic diameter or area has been used as a measure of preload. However, Tavernier et al. and Feissel et al. [19, 20] have demonstrated that LV size (left ventricular end diastolic area LVEDA) is not a useful predictor of fluid responsiveness in patients on mechanical ventilation, unless LV is very small and hyperkinetic. A meta-analysis by Marik et al. [21] demonstrated the failure of the LVEDA to predict volume responsiveness in mechanically ventilated patients. Generally speaking, static parameters appear to be poor predictors of volume responsiveness except in patients with relatively obvious hypovolemia, which is a relatively uncommon event in modern ICU practice. It can, therefore, be concluded, that standard static indices of preload are not useful in predicting volume responsiveness in ICU patients. This observation may be due to dynamic changes in left (LV) and to a lesser degree right ventricular (RV) compliance, making the diastolic pressure-volume relationship nonlinear, unpredictable, and perhaps subject to change during resuscitation itself. Systolic left ventricular function is also a subject to change in critically ill patients, even those, without preexistent cardiac disease. Vieillard-Baron and coauthors demonstrated the development of systolic left ventricular dysfunction in 60% of patient with septic shock [6]. Changing left ventricular function makes it difficult to predict the position of the patient on his/her Frank-Starling

3 Cardiology Research and Practice 3 curve. It is even difficult to estimate which family of Frank- Starling relationships should be utilized to predict fluid responsiveness (see Figure1). Furthermore, the development of acute right ventricular failure (acute cor pulmonale), particularly in patients receiving mechanical ventilation with high plateau pressures (>27 cm H 2 O), further confounds the issue [22]. Unrecognized acute right ventricular failure can mimic hypovolemia hemodynamically but would not respond or even get worse with volume expansion. Dynamic hemodynamic parameters offer the intensivists the best opportunity of predicting response to fluid resuscitation. 5. Dynamic Parameters of Volume Responsiveness Dynamic parameters are used to determine the patients position on his/her Frank-Starling curve (Figure 1) and specifically to determine whether the patient is situated on the ascending portion of the Frank-Starling curve where an increase of preload results in increase of stroke volume (SV) (preload-dependent situation), or on the plateau portion where a variation of preload does not alter SV (preloadindependent situation). Several approaches can be used to determine on what portion of the preload/stroke volume relationship the ventricle is functioning to establish the diagnosis of preload dependence or independence. Most utilize observation of cardiac response to either mechanical or spontaneous breathing cycle and breathing related variations in intrathoracic pressure. These pressure changes directly effect RV and LV preload and provides a tool to correlate these preload changes to SV. Alternatively, bedside maneuvers such as passive leg raising (PLR) result in alterations of RV and LV preload can be utilized to establish similar correlations Ventilated versus Spontaneously Breathing Patient. By significantly increasing RV preload, spontaneous breathing is crucial to maintaining normal hemodynamic status. Mechanical ventilation substantially increases intrathoracic pressure, decreasing RV preload and thus has predictably negative hemodynamic consequences. Moreover, traditional positive pressure ventilation also reverses inspiration/expiration phases from a hemodynamic point of view, changing many breathing related phenomena (i.e., paradoxical pulse) to its opposite (reverse pulsus paradoxus) [23] Dynamic Echocardiographic Parameters in Patients on Mechanical Ventilation. Analysis of the respiratory changes of LV stroke volume during mechanical ventilation provides a dynamic, biventricular evaluation of preload dependence. The respiratory changes of stroke volume can be estimated by Doppler analysis of velocity-time integral (VTI) during TTE or TEE. In clinical studies, maximal ascending aortic flow velocity or VTI variation measured with TEE predict, with high sensitivity and specificity, increases in cardiac output after fluid infusion in patients with septic shock. A cut-off value of respiratory cycle changes of 12% for maximal flow velocity and 20% for aortic VTI-discriminated responders from nonresponders [20]. Similar information that can be obtained from interrogation of ascending aorta with TTE (Figure 2) or descending aorta. Another approach to identify volume responsiveness used 2D images. Cannesson et al. [24] assessed LV diastolic area (LVDA) changes by TEE from the short axis view. They found that a 16% respiratory variation of LVDA predicted fluid responsiveness with a sensitivity of 92% and a specificity of 83%. Utilizing a similar principle, IVC and superior vena cava (SVC) diameter changes during mechanical ventilation can be used to predict fluid responsiveness (see Figure 3). The inferior vena cava diameter by TTE is analyzed from a subcostal long axis view and recorded by using M mode. The superior vena cava diameter is recorded from TEE longitudinal view at Cut-off values of 12% (by using (max min)/mean value)) and 18% (by using (max min)/min value) for IVC (distensibility index) and 36% for SVC (collapsibility index) were found to accurately (sensitivity 90%, specificity 100%) separate responders and non-responders that as an intrathoracic. The potential benefit of using SVC is due to the fact that as intrathoracic organ the SVC is subject to greater respiratory variations and intrathoracic pressure resulting from mechanical ventilation. Though SVC collapsibility appears to be the most reliable index of volume responsiveness, it does require TEE [25] and thus is out of reach of most intensivists in the United States. Ventilator induced preload changes as predictors of volume responsiveness have only been evaluated in patients on flow limited, volume cycled ventilation and without patient ventilator dyssynchrony. Furthermore, although the level of positive end expiratory pressure (PEEP) is known to influence venous return and biventricular function the effect of PEEP on echocardiographic assessment of volume responsiveness has not been studied. Other requirements include presence of a normal sinus rhythm, normal intraabdominal pressure and absence of significant RV dysfunction. Although a positive response to PLR seems to be predictive of volume responsiveness in mechanically ventilated patients (sensitivity 90% specificity 83%) [26] further studies are necessary to better understand the role of this bedside maneuver in this population of critically ill patients Dynamic Echocardiographic Parameters in Spontaneously Breathing Patients. Several publications have proposed using PLR maneuver to predict preload responsiveness (Figure 4). This maneuver rapidly mobilizes about ml of blood from the lower limbs to the intrathoracic compartment and reproduces the effects of similar volume fluid bolus (Figure 1). Being completely reversible this maneuver is devoid of any risks associated with an actual fluid challenge. The test consists of raising both legs of the supine patient to an angle of 45 in relation to the bed while measuring SV and cardiac output before and immediately (1 3 minutes) following the PLR maneuver. This may be accomplished by measuring the VTI of the aortic outflow with either TTE (apical five-chamber view) or TEE (deepgastric view). Monnetetal. [27] demonstrated that when

4 4 Cardiology Research and Practice Stroke volume Preload responsiveness Preload unresponsiveness b a b a A B Ventricular preload PLR Figure 1: Depending on LV systolic function two distinct families of Frank-Starling relationships are formed, exemplified by solid and interrupted lines. Patients with hemodynamics following solid line pattern (preserved left ventricular systolic function) are more likely to benefit from preload manipulation, then those following the interrupted line pattern (reduced left ventricular systolic function). When Ventricle is functioning on the steep part of the Frank-Starling curve, there is a preload reserve. The passive leg raising (PLR) test (and a fluid challenge) increases stroke volume. By contrast, once the ventricle is operating near the flat part of the curve, there is no preload reserve and PLR (and a fluid challenge) has little effect on the stroke volume. (a) (b) (c) (d) Figure 2: Respiratory variations of maximal velocity (Vmax) (a and c) and VTI (b and d) of aortic blood flow recorded with a pulsed Doppler transthoracic echocardiography in a mechanically ventilated patient (a and c). Presence of significant respiratory variations of Vmax (Vmax Vmin/[Vmax + Vmin/2]; /1.19 = 17%) and VTI (VTImax VTImin/[VTImax + VTI min/2]; /19 = 18%). (b and d) Same patient after volume expansion, regression of the respiratory variations: Vmax ( /1.34 = 4%), VTI ( /22.9 = 5%). Reproduced with permission from Levitov et al. Critical care Ultrasonography Mc Graw Hill 2009.

5 Cardiology Research and Practice 5 (a) (b) (c) Figure 3: Respiratory vena cava variations in different circumstances. (a) Significant superior vena cava (SVC) collapsibility recorded with transesophageal echocardiography (TEE). (b) Significant inferior vena cava (IVC) distensibility recorded with transthoracic echocardiography (TTE) in a mechanically ventilated patient. (c) Significant vena cava collapsibility recorded with transthoracic echocardiography (TTE) in a spontaneously breathing patient. Reproduced with permission from Levitov et al. Critical care Ultrasonography Mc Graw Hill (a) (b) (c) Figure 4: The realization of a passive leg raising maneuver in three steps: (a) at baseline the patient is laying in a semirecumbent position, the trunk of the patient at 45 up to the horizontal; (b) the entire bed is pivoted to obtain a head down tilt at 45. (c) The head of the bed is adjusted to obtain a strictly horizontal. PLR induced an increase of aortic flow of >10%, it was predictive of an increase of aortic flow of >15% in response to volume expansion (sensitivity: 97%; specificity: 94%). Volume expansion was performed with 500 ml of isotonic saline over 10 minutes. Thirty-seven (52%) of the 71 patients included in this study responded to volume expansion; 22 subjects had spontaneous breathing activity (spontaneous breathing mode with inspiratory assistance). This study also evaluated respiratory cycle induced pulse pressure variations. The authors concluded that respiratory cyclic variations of pulse pressure 12% were similarly predictive of an increase of aortic flow by >15% in response to volume expansion in mechanically ventilated patients (sensitivity: 88%; specificity: 93%). However, in spontaneously breathing patient s predictive value of respiratory pulse pressure variations was poor. In two other studies aortic VTI, stroke volume and cardiac output were recorded using transthoracic echocardiography in spontaneously breathing patients

6 6 Cardiology Research and Practice during a PLR maneuver. Lamia et al. [28] demonstrateda PLR-induced increase in stroke volume of 12.5% or more predicted an increase in stroke volume of 15% or more after volume expansion, with a sensitivity of 77% and a specificity of 100%. In this study, patients were intubated with spontaneous breathing. Static indices of preload such as left ventricular diastolic area and E/Ea ratio failed to predict volume responsiveness. Maizel et al. [29] studied 34 spontaneously breathing patients; an increase of cardiac output or stroke volume by >12% during PLR was highly predictive of volume responsiveness. Sensitivity and specificity values were 63% and 89%, respectively. In addition, this study demonstrated that PLR may be used to predict volume responsiveness in patients with atrial fibrillation. Increased intraabdominal pressure, however, strongly interferes with the ability of PLR to predict fluid responsiveness [30]. In conclusion, echocardiography provides the intensivist with several methods to determine volume responsiveness in patients with hemodynamic failure. The clinician with basic skills in critical care echocardiography may use respiratory variation of IVC diameter to identify the preload-dependent patient combined with pattern recognition of small hyperdynamic LV. The intensivist with advanced TTE skill level may use respiratory variation of SV determined by Doppler echocardiography (VTI) and changes in SV following the PLR maneuver to identify volume responsiveness. Intensivist with TEE skills may effectively utilize this modality in patients presenting technical challenge for TTE. Advent of minimally invasive TEE monitoring probes might allow intensivist views of SVC not available on TTE and real time LV and RV function monitoring abilities, previously unavailable at bedside. Widespread use of newer modes of mechanical ventilation (APRV, HFOV) provides new challenges and opportunities for the evaluation of their effect of cardiac performance and volume responsiveness. Further studies are necessary to determine if this increase in physiological insight will translate into improved outcomes of critically ill patients. Conflict of Interests The authors declare that they have no conflict of interests. References [1] E. Rivers, B. Nguyen, S. Havstad et al., Early goal-directed therapy in the treatment of severe sepsis and septic shock, New England Medicine, vol. 345, no. 19, pp , [2] P. E. Marik, R. Cavallazzi, T. Vasu, and A. Hirani, Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature, Critical Care Medicine, vol. 37, no. 9, pp , [3] S. Boussat, T. Jacques, B. Levy et al., Intravascular volume monitoring and extravascular lung water in septic patients with pulmonary edema, Intensive Care Medicine, vol. 28, no. 6, pp , [4] B. Benomar, A. Ouattara, P. Estagnasie, A. Brusset, and P. Squara, Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test, Intensive Care Medicine, vol. 36, no. 11, pp , [5] A. R. Manasia, H. M. Nagaraj, R. B. Kodali et al., Feasibility and potential clinical utility of goal-directed transthoracic echocardiography performed by noncardiologist intensivists using a small hand-carried device (SonoHeart) in critically ill patients, Cardiothoracic and Vascular Anesthesia, vol. 19, no. 2, pp , [6] A. Vieillard-Baron, V. Caille, C. Charron, G. Belliard, B. Page, and F. Jardin, Actual incidence of global left ventricular hypokinesia in adult septic shock, Critical Care Medicine, vol. 36, no. 6, pp , [7] H. P. Wiedemann, A. P. Wheeler, G. R. Bernard et al., Comparison of two fluid-management strategies in acute lung injury, New England Medicine, vol. 354, no. 24, pp , [8]J.H.Boyd,J.Forbes,T.A.Nakada,K.R.Walley,andJ.A. Russell, Fluid resuscitation in septic shock: a positive fluid balance and elevated central venous pressure are associated with increased mortality, Critical Care Medicine, vol. 39, no. 2, pp , [9] C. V. Murphy, G. E. Schramm, J. A. Doherty et al., The importance of fluid management in acute lung injury secondary to septic shock, Chest, vol. 136, no. 1, pp , [10] A. L. Rosenberg, R. E. Dechert, P. K. Park, and R. H. Bartlett, Review of a large clinical series: association of cumulative fluid balance on outcome in acute lung injury: a retrospective review of the ARDSnet tidal volume study cohort, Intensive Care Medicine, vol. 24, no. 1, pp , [11] A. F. Connors, T. Speroff, N.V.Dawsonetal., Theeffectiveness of right heart catheterization in the initial care of critically ill patients, the American Medical Association, vol. 276, no. 11, pp , [12] P. E. Marik, M. Baram, and B. Vahid, Does central venous pressure predict fluid responsiveness? Chest, vol. 134, no. 1, pp , [13] L. A. McIntyre, P. C. Hébert, D. Fergusson, D. J. Cook, and A. Aziz, A survey of Canadian intensivists resuscitation practices in early septic shock, Critical Care, vol. 11, article R74, [14] R. P. Dellinger, M. M. Levy, J. M. Carlet et al., Surviving sepsis campaign: international guidelines for management of severe sepsis and septic shock: 2008, Critical Care Medicine, vol. 36, no. 1, pp , [15] A. Kumar, R. Anel, E. Bunnell et al., Pulmonary artery occlusion pressure and central venous pressure fail to predict ventricular filling volume, cardiac performance, or the response to volume infusion in normal subjects, Critical Care Medicine, vol. 32, no. 3, pp , [16] F. Michard and J. L. Teboul, Predicting fluid responsiveness in ICU patients: a critical analysis of the evidence, Chest, vol. 121, no. 6, pp , [17] A. Coudray, J. A. Romand, M. Treggiari, and K. Bendjelid, Fluid responsiveness in spontaneously breathing patients: a review of indexes used in intensive care, Critical Care Medicine, vol. 33, no. 12, pp , [18] M. Feissel, F. Michard, J. P. Faller, and J. L. Teboul, The respiratory variation in inferior vena cava diameter as a guide to fluid therapy, Intensive Care Medicine, vol. 30, no. 9, pp , [19] B. Tavernier, O. Makhotine, G. Lebuffe, J. Dupont, and P. Scherpereel, Systolic pressure variation as a guide to fluid therapy in patients with sepsis-induced hypotension, Anesthesiology, vol. 89, no. 6, pp , 1998.

7 Cardiology Research and Practice 7 [20] M. Feissel, F. Michard, I. Mangin, O. Ruyer, J. P. Faller, and J. L. Teboul, Respiratory changes in aortic blood velocity as an indicator of fluid responsiveness in ventilated patients with septic shock, Chest, vol. 119, no. 3, pp , [21] P. E. Marik, R. Cavallazzi, and T. Vasu, Stroke volume variations and fluid responsiveness. A systematic review of literature, Critical Care Medicine, vol. 37, pp , [22] F. Jardin and A. Vieillard-Baron, Is there a safe plateau pressure in ARDS? The right heart only knows, Intensive Care Medicine, vol. 33, no. 3, pp , [23]R.A.Massumi,D.T.Mason,Z.Vera,R.Zelis,J.Otero,and E. A. Amsterdam, Reversed pulsus paradoxus, New England Medicine, vol. 289, no. 24, pp , [24] M. Cannesson, J. Slieker, O. Desebbe, F. Farhat, O. Bastien, and J. J. Lehot, Prediction of fluid responsiveness using respiratory variations in left ventricular stroke area by transoesophageal echocardiographic automated border detection in mechanically ventilated patients, Critical Care, vol. 10, article R171, [25] C. Charron, V. Caille, F. Jardin, and A. Vieillard-Baron, Echocardiographic measurement of fluid responsiveness, Current Opinion in Critical Care, vol. 12, no. 3, pp , [26] A. Lafanechère, F. Pène, C. Goulenok et al., Changes in aortic blood flow induced by passive leg raising predict fluid responsiveness in critically ill patients, Critical Care, vol. 10, no. 5, article R132, [27] X. Monnet, M. Rienzo, D. Osman et al., Passive leg raising predicts fluid responsiveness in the critically ill, Critical Care Medicine, vol. 34, no. 5, pp , [28] B. Lamia, A. Ochagavia, X. Monnet, D. Chemla, C. Richard, and J. L. Teboul, Echocardiographic prediction of volume responsiveness in critically ill patients with spontaneously breathing activity, Intensive Care Medicine, vol.33,no.7,pp , [29] J. Maizel, N. Airapetian, E. Lorne, C. Tribouilloy, Z. Massy, and M. Slama, Diagnosis of central hypovolemia by using passive leg raising, Intensive Care Medicine, vol. 33, no. 7, pp , [30] Y. Mahjoub, J. Touzeau, N. Airapetian et al., The passive legraising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension, Critical Care Medicine, vol. 38, no. 9, pp , 2010.

8 MEDIATORS of INFLAMMATION The Scientific World Journal Gastroenterology Research and Practice Diabetes Research International Endocrinology Immunology Research Disease Markers Submit your manuscripts at BioMed Research International PPAR Research Obesity Ophthalmology Evidence-Based Complementary and Alternative Medicine Stem Cells International Oncology Parkinson s Disease Computational and Mathematical Methods in Medicine AIDS Behavioural Neurology Research and Treatment Oxidative Medicine and Cellular Longevity

Volume Responsiveness in Critically Ill Patients

Volume Responsiveness in Critically Ill Patients SOUND JUDGMENT SERIES Volume Responsiveness in Critically Ill Patients Use of Sonography to Guide Management David Evans, MD, Giovanna Ferraioli, MD, John Snellings, MD, Alexander Levitov, MD Invited paper

More information

Utility of transthoracic echocardiography (TTE) in assessing fluid responsiveness in critically ill patients a challenge for the bedside sonographer

Utility of transthoracic echocardiography (TTE) in assessing fluid responsiveness in critically ill patients a challenge for the bedside sonographer Continuing education Med Ultrason 2016, Vol. 18, no. 4, -514 DOI: 10.11152/mu-880 Utility of transthoracic echocardiography (TTE) in assessing fluid responsiveness in critically ill patients a challenge

More information

Preload optimisation in severe sepsis and septic shock

Preload optimisation in severe sepsis and septic shock Preload optimisation in severe sepsis and septic shock Prof. Jean-Louis TEBOUL Medical ICU Bicetre hospital University Paris South France Conflicts of interest Member of themedical Advisory Board ofpulsion

More information

Fluid responsiveness and extravascular lung water

Fluid responsiveness and extravascular lung water Fluid responsiveness and extravascular lung water Prof. Jean-Louis TEBOUL Medical ICU Bicetre hospital University Paris-South France Conflicts of interest Member of the Medical Advisory Board of Maquet/Pulsion

More information

ICU Volume 12 - Issue 4 - Winter 2012/ Matrix Features

ICU Volume 12 - Issue 4 - Winter 2012/ Matrix Features ICU Volume 12 - Issue 4 - Winter 2012/2013 - Matrix Features Fluid Management in Critically Ill Patients: A Guided Approach Prof. Antonio Artigas, MD, PhD ICU Management & Practice Editorial Board Member

More information

Jan M. Headley, R.N. BS

Jan M. Headley, R.N. BS Fluid First: Using PLR & SVV to Optimize Volume Jan M. Headley, R.N. BS Disclosure Director, Clinical Marketing & Professional Education Edwards Lifesciences Does this Patient NEED Fluid?? WE Have a Problem

More information

Prof. Dr. Iman Riad Mohamed Abdel Aal

Prof. Dr. Iman Riad Mohamed Abdel Aal The Use of New Ultrasound Indices to Evaluate Volume Status and Fluid Responsiveness in Septic Shock Patients Thesis Submitted for partial fulfillment of MD degree in Anesthesiology, Surgical Intensive

More information

Online Supplement. Hemodynamic Assessment of Patients With Septic Shock Using Transpulmonary Thermodilution and Critical Care Echocardiography

Online Supplement. Hemodynamic Assessment of Patients With Septic Shock Using Transpulmonary Thermodilution and Critical Care Echocardiography Online Supplement Hemodynamic Assessment of Patients With Septic Shock Using Transpulmonary Thermodilution and Critical Care Echocardiography A Comparative Study Philippe Vignon, MD, PhD; Emmanuelle Begot,

More information

CHAPTER 13. Fluid Responsiveness

CHAPTER 13. Fluid Responsiveness CHAPTER 13 Fluid Responsiveness SECTION 1 Introduction Administration of an intravenous fluid challenge is a common medical intervention in the hypotensive or hypovolemic patient. Ideally, a fluid challenge

More information

Hemodynamic monitoring beyond cardiac output

Hemodynamic monitoring beyond cardiac output Hemodynamic monitoring beyond cardiac output Prof Xavier MONNET Medical Intensive Care Unit Bicêtre Hospital Assistance publique Hôpitaux de Paris FRANCE Conflicts of interest Lilly GlaxoSmithKline Pulsion

More information

FLUID RESUSCITATION AND MONITORING IN SEPSIS PROTOCOLIZED VS USUAL CARE DEEPA BANGALORE GOTUR MD, FCCP ASSISTANT PROFESSOR, WEILL CORNELL MEDICAL

FLUID RESUSCITATION AND MONITORING IN SEPSIS PROTOCOLIZED VS USUAL CARE DEEPA BANGALORE GOTUR MD, FCCP ASSISTANT PROFESSOR, WEILL CORNELL MEDICAL FLUID RESUSCITATION AND MONITORING IN SEPSIS PROTOCOLIZED VS USUAL CARE DEEPA BANGALORE GOTUR MD, FCCP ASSISTANT PROFESSOR, WEILL CORNELL MEDICAL COLLEGE NOVEMBER 10 TH 2017 TEXAS SCCM SYMPOSIUM Disclosures

More information

Using Functional Hemodynamic Indicators to Guide Fluid Therapy

Using Functional Hemodynamic Indicators to Guide Fluid Therapy CE 2.6 HOURS Continuing Education Using Functional Hemodynamic Indicators to Guide Fluid Therapy A more accurate and less invasive way to gauge responsiveness to iv volume replacement. OVERVIEW: Hemodynamic

More information

Assessing Preload Responsiveness Using Arterial Pressure Based Technologies. Patricia A. Meehan, RN, MS Education Consultant Edwards Lifesciences, LLC

Assessing Preload Responsiveness Using Arterial Pressure Based Technologies. Patricia A. Meehan, RN, MS Education Consultant Edwards Lifesciences, LLC Assessing Preload Responsiveness Using Arterial Pressure Based Technologies Patricia A. Meehan, RN, MS Education Consultant Edwards Lifesciences, LLC Content Description : Fluid administration is a first

More information

Tailored Volume Resuscitation in the Critically Ill is Achievable. Objectives. Clinical Case 2/16/2018

Tailored Volume Resuscitation in the Critically Ill is Achievable. Objectives. Clinical Case 2/16/2018 Tailored Volume Resuscitation in the Critically Ill is Achievable Heath E Latham, MD Associate Professor Fellowship Program Director Pulmonary and Critical Care Objectives Describe the goal of resuscitation

More information

Sepsis Wave II Webinar Series. Sepsis Reassessment

Sepsis Wave II Webinar Series. Sepsis Reassessment Sepsis Wave II Webinar Series Sepsis Reassessment Presenters Nova Panebianco, MD Todd Slesinger, MD Fluid Reassessment in Sepsis Todd L. Slesinger, MD, FACEP, FCCM, FCCP, FAAEM Residency Program Director

More information

Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge*

Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge* Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge* David Osman, MD; Christophe Ridel, MD; Patrick Ray, MD; Xavier Monnet, MD, PhD; Nadia Anguel, MD; Christian

More information

3/14/2017. Disclosures. None. Outline. Fluid Management and Hemodynamic Assessment Paul Marik, MD, FCCP, FCCM

3/14/2017. Disclosures. None. Outline. Fluid Management and Hemodynamic Assessment Paul Marik, MD, FCCP, FCCM Fluid Management and Hemodynamic Assessment Paul Marik, MD, FCCP, FCCM Disclosures Stocks Advisory boards Grants Speakers Bureau None Outline Hemodynamic Goals Fluid Resuscitation Historical Perspective

More information

Purist? or Pragmatist? Assessment & Management of ICU Volume Status

Purist? or Pragmatist? Assessment & Management of ICU Volume Status Assessment & Management of ICU Volume Status 9 th Annual Rocky Mountain Hospital Medicine Symposium Denver, Colorado Paula Dennen, MD Assistant Professor of Medicine Nephrology and Critical Care Medicine

More information

FLUIDS AND SOLUTIONS IN THE CRITICALLY ILL. Daniel De Backer Department of Intensive Care Erasme University Hospital Brussels, Belgium

FLUIDS AND SOLUTIONS IN THE CRITICALLY ILL. Daniel De Backer Department of Intensive Care Erasme University Hospital Brussels, Belgium FLUIDS AND SOLUTIONS IN THE CRITICALLY ILL Daniel De Backer Department of Intensive Care Erasme University Hospital Brussels, Belgium Why do we want to administer fluids? To correct hypovolemia? To increase

More information

Index. K Knobology, TTE artifact, image resolution, ultrasound, 14

Index. K Knobology, TTE artifact, image resolution, ultrasound, 14 A Acute aortic regurgitation (AR), 124 128 Acute aortic syndrome (AAS) classic aortic dissection diagnosis, 251 263 evolutive patterns, 253 255 pathology, 250 251 classifications, 247 248 incomplete aortic

More information

Hemodynamic Monitoring Pressure or Volumes? Antonio Pesenti University of Milan Italy

Hemodynamic Monitoring Pressure or Volumes? Antonio Pesenti University of Milan Italy Hemodynamic Monitoring Pressure or Volumes? Antonio Pesenti University of Milan Italy antonio.pesenti@unimi.it CCCF 2017 Is it useful? YES: CVP It is an important diagnostic element! Your best guess CVP

More information

Sepsis Update: Focus on Early Recognition and Intervention. Disclosures

Sepsis Update: Focus on Early Recognition and Intervention. Disclosures Sepsis Update: Focus on Early Recognition and Intervention Jessie Roske, MD October 2017 Disclosures I have no actual or potential conflict of interest in relation to this program/presentation. I will

More information

Case Report Sinus Venosus Atrial Septal Defect as a Cause of Palpitations and Dyspnea in an Adult: A Diagnostic Imaging Challenge

Case Report Sinus Venosus Atrial Septal Defect as a Cause of Palpitations and Dyspnea in an Adult: A Diagnostic Imaging Challenge Case Reports in Medicine Volume 2015, Article ID 128462, 4 pages http://dx.doi.org/10.1155/2015/128462 Case Report Sinus Venosus Atrial Septal Defect as a Cause of Palpitations and Dyspnea in an Adult:

More information

Echocardiography to guide fluid therapy in critically ill patients: check the heart and take a quick look at the lungs

Echocardiography to guide fluid therapy in critically ill patients: check the heart and take a quick look at the lungs Editorial Echocardiography to guide fluid therapy in critically ill patients: check the heart and take a quick look at the lungs Federico Franchi 1 *, Luigi Vetrugno 2 *, Sabino Scolletta 1 1 Department

More information

Arterial Pulse Pressure Variation During Positive Pressure Ventilation and Passive Leg Raising

Arterial Pulse Pressure Variation During Positive Pressure Ventilation and Passive Leg Raising Arterial Pulse Pressure Variation During Positive Pressure Ventilation and Passive Leg Raising J.-L. Teboul, X. Monnet, and C. Richard Introduction Inadequate cardiac preload can play a major role in the

More information

Echocardiography as a diagnostic and management tool in medical emergencies

Echocardiography as a diagnostic and management tool in medical emergencies Echocardiography as a diagnostic and management tool in medical emergencies Frank van der Heusen MD Department of Anesthesia and perioperative Care UCSF Medical Center Objective of this presentation Indications

More information

Invasive Cardiac Output Monitoring and Pulse Contour Analysis. Harshad B. Ranchod Paediatric Intensivist Chris Hani Baragwanath Hospital COPICON 2011

Invasive Cardiac Output Monitoring and Pulse Contour Analysis. Harshad B. Ranchod Paediatric Intensivist Chris Hani Baragwanath Hospital COPICON 2011 Invasive Cardiac Output Monitoring and Pulse Contour Analysis Harshad B. Ranchod Paediatric Intensivist Chris Hani Baragwanath Hospital COPICON 2011 Introduction The primary goal of haemodynamic monitoring

More information

The cornerstone of treating patients with hypotension,

The cornerstone of treating patients with hypotension, Does the Central Venous Pressure Predict Fluid Responsiveness? An Updated Meta-Analysis and a Plea for Some Common Sense* Paul E. Marik, MD, FCCM 1 ; Rodrigo Cavallazzi, MD 2 Background: Aim: Data Sources:

More information

Assessing volume status and fluid responsiveness in the emergency department

Assessing volume status and fluid responsiveness in the emergency department Clin Exp Emerg Med 2014;1(2):67-77 http://dx.doi.org/10.15441/ceem.14.040 Assessing volume status and fluid responsiveness in the emergency department David C. Mackenzie 1, Vicki E. Noble 2 1 Department

More information

Fluid optimization strategies in critical care patients

Fluid optimization strategies in critical care patients Perioperative & Critical Care Medicine Page 1 of 5 Fluid optimization strategies in critical care patients X García*, G Gruartmoner, J Mesquida Abstract Introduction Fluid optimization is an important

More information

Bioreactance-based passive leg raising test can predict fluid responsiveness in elderly patients with septic shock

Bioreactance-based passive leg raising test can predict fluid responsiveness in elderly patients with septic shock Original Article Page 1 of 6 Bioreactance-based passive leg raising test can predict fluid responsiveness in elderly patients with septic shock Caibao Hu 1 *, Guolong Cai 1 *, Jing Yan 1, Hongjie Tong

More information

Respiratory Physiology and the Impact of Different Modes of Ventilation on the Photoplethysmographic Waveform

Respiratory Physiology and the Impact of Different Modes of Ventilation on the Photoplethysmographic Waveform Sensors 2012, 12, 2236-2254; doi:10.3390/s120202236 Review OPEN ACCESS sensors ISSN 1424-8220 www.mdpi.com/journal/sensors Respiratory Physiology and the Impact of Different Modes of Ventilation on the

More information

Swan Ganz catheter: Does it still have a role? Daniel De Backer Department of Intensive Care Erasme University Hospital Brussels, Belgium

Swan Ganz catheter: Does it still have a role? Daniel De Backer Department of Intensive Care Erasme University Hospital Brussels, Belgium Swan Ganz catheter: Does it still have a role? Daniel De Backer Department of Intensive Care Erasme University Hospital Brussels, Belgium How can cardiac output be measured? Thermodilution Arterial waveform

More information

The Use of Dynamic Parameters in Perioperative Fluid Management

The Use of Dynamic Parameters in Perioperative Fluid Management The Use of Dynamic Parameters in Perioperative Fluid Management Gerard R. Manecke Jr., M.D. Chief, Cardiac Anesthesia UCSD Medical Center San Diego, CA, USA Thanks to Tom Higgins, M.D. 1 Goals of today

More information

Echocardiography Volume assessment. Justin Mandeville 2014

Echocardiography Volume assessment. Justin Mandeville 2014 Echocardiography Volume assessment Justin Mandeville 2014 Volume assessment and the intensivist Hypovolaemic shock Fluid tolerance Optimising cardiac output Avoiding overloading Guided fluid removal Add

More information

Disclaimer. Improving MET-based patient care using treatment algorithms. Michael R. Pinsky, MD, Dr hc. Different Environments Demand Different Rules

Disclaimer. Improving MET-based patient care using treatment algorithms. Michael R. Pinsky, MD, Dr hc. Different Environments Demand Different Rules Michael R. Pinsky, MD - June 29, 26 Improving MET-based patient care using Michael R. Pinsky, MD, Dr hc Department of Critical Care Medicine University of Pittsburgh Disclaimer Michael R. Pinsky, MD is

More information

Review Article. Interactive Physiology in Critical Illness : Pulmonary and Cardiovascular Systems. Introduction

Review Article. Interactive Physiology in Critical Illness : Pulmonary and Cardiovascular Systems. Introduction 310 Indian Deepak J Physiol Shrivastava Pharmacol 2016; 60(4) : 310 314 Indian J Physiol Pharmacol 2016; 60(4) Review Article Interactive Physiology in Critical Illness : Pulmonary and Cardiovascular Systems

More information

Point-of-Care Ultrasound Closer look at the Inferior Vena Cavae &

Point-of-Care Ultrasound Closer look at the Inferior Vena Cavae & Point-of-Care Ultrasound Closer look at the Inferior Vena Cavae & Brief Introduction to Gross Systolic Function Omar S. Darwish, MS, DO Certified in Point-of-Care Ultrasound Hospitalist University of California,

More information

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the Edwards PreSep oximetry catheter

The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the Edwards PreSep oximetry catheter 1 2 The Vigileo monitor by Edwards Lifesciences supports both the FloTrac Sensor for continuous cardiac output and the Edwards PreSep oximetry catheter for continuous central venous oximetry (ScvO2) 3

More information

DESIGNER RESUSCITATION: TITRATING TO TISSUE NEEDS

DESIGNER RESUSCITATION: TITRATING TO TISSUE NEEDS DESIGNER RESUSCITATION: TITRATING TO TISSUE NEEDS R. Phillip Dellinger MD, MSc, MCCM Professor and Chair of Medicine Cooper Medical School of Rowan University Chief of Medicine Cooper University Hospital

More information

Goal-directed resuscitation in sepsis; a case-based approach

Goal-directed resuscitation in sepsis; a case-based approach Goal-directed resuscitation in sepsis; a case-based approach Jorge A Guzman, MD, FCCM Head, Section Critical Care Medicine Respiratory Institute Cleveland Clinic Foundation The challenges to managing septic

More information

IN THE NAME OF GOD SHOCK MANAGMENT OMID MORADI MOGHADDAM,MD,FCCM IUMS ASSISTANT PROFESSOR

IN THE NAME OF GOD SHOCK MANAGMENT OMID MORADI MOGHADDAM,MD,FCCM IUMS ASSISTANT PROFESSOR IN THE NAME OF GOD SHOCK MANAGMENT OMID MORADI MOGHADDAM,MD,FCCM IUMS ASSISTANT PROFESSOR The ability to evaluate and manage a critically ill patient is one of the most important skills any intensivist

More information

ENDPOINTS OF RESUSCITATION

ENDPOINTS OF RESUSCITATION ENDPOINTS OF RESUSCITATION Fred Pieracci, MD, MPH Acute Care Surgeon Denver Health Medical Center Assistant Professor of Surgery University of Colorado Health Science Center OUTLINE Recognition and characterization

More information

Predicting fluid responsiveness in the intensive care unit: a clinical guide

Predicting fluid responsiveness in the intensive care unit: a clinical guide review Netherlands Journal of Critical Care Copyright 2008, Nederlandse Vereniging voor Intensive Care. All Rights Reserved. Received June 2008; accepted January 2009 Predicting fluid responsiveness in

More information

Patrick C. Cullinan, DO, NBPNS, FCCM, FACOEP, FACOI Associate Clinical Professor, UIWSOM, San Antonio, Texas Adjunct Assistant Professor, University

Patrick C. Cullinan, DO, NBPNS, FCCM, FACOEP, FACOI Associate Clinical Professor, UIWSOM, San Antonio, Texas Adjunct Assistant Professor, University Patrick C. Cullinan, DO, NBPNS, FCCM, FACOEP, FACOI Associate Clinical Professor, UIWSOM, San Antonio, Texas Adjunct Assistant Professor, University of Texas Health Science Center, Department of Emergency

More information

Shock, Monitoring Invasive Vs. Non Invasive

Shock, Monitoring Invasive Vs. Non Invasive Shock, Monitoring Invasive Vs. Non Invasive Paula Ferrada MD Assistant Professor Trauma, Critical Care and Emergency Surgery Virginia Commonwealth University Shock Fluid Pressors Ionotrope Intervention

More information

6/5/2014. Sepsis Management and Hemodynamics. 2004: International group of experts,

6/5/2014. Sepsis Management and Hemodynamics. 2004: International group of experts, Sepsis Management and Hemodynamics Javier Perez-Fernandez, M.D., F.C.C.P. Medical Director Critical Care Services, Baptist t Hospital of Miamii Medical Director Pulmonary Services, West Kendall Baptist

More information

Nurse Driven Fluid Optimization Using Dynamic Assessments

Nurse Driven Fluid Optimization Using Dynamic Assessments Nurse Driven Fluid Optimization Using Dynamic Assessments 2016 1 WHAT WE BELIEVE We believe that clinicians make vital fluid and drug decisions every day with limited and inconclusive information Cheetah

More information

Protocolized Cardiovascular Management Based on Ventricular-arterial Coupling

Protocolized Cardiovascular Management Based on Ventricular-arterial Coupling Protocolized Cardiovascular Management Based on Ventricular-arterial Coupling M. R. Pinsky Introduction Central to the management of any hemodynamically unstable patient is the rapid assessment of the

More information

Sepsis Management: Past, Present, and Future

Sepsis Management: Past, Present, and Future Sepsis Management: Past, Present, and Future Benjamin Ferrell, MD Tennessee ACP Meeting October 28, 2017 Learning Objectives Identify the most updated definition and clinical criteria for sepsis Describe

More information

Fluid Resuscitation and Monitoring in Sepsis. Deepa Gotur, MD, FCCP Anne Rain T. Brown, PharmD, BCPS

Fluid Resuscitation and Monitoring in Sepsis. Deepa Gotur, MD, FCCP Anne Rain T. Brown, PharmD, BCPS Fluid Resuscitation and Monitoring in Sepsis Deepa Gotur, MD, FCCP Anne Rain T. Brown, PharmD, BCPS Learning Objectives Compare and contrast fluid resuscitation strategies in septic shock Discuss available

More information

Bedside echocardiographic evaluation of hemodynamics in sepsis: is a qualitative evaluation sufficient?

Bedside echocardiographic evaluation of hemodynamics in sepsis: is a qualitative evaluation sufficient? Intensive Care Med (2006) 32:1547 1552 DOI 10.1007/s00134-006-0274-7 ORIGINAL Antoine Vieillard-Baron Cyril Charron Karim Chergui Olivier Peyrouset François Jardin Bedside echocardiographic evaluation

More information

Hemodynamic Monitoring

Hemodynamic Monitoring Perform Procedure And Interpret Results Hemodynamic Monitoring Tracheal Tube Cuff Pressure Dean R. Hess PhD RRT FAARC Hemodynamic Monitoring Cardiac Rate and Rhythm Arterial Blood Pressure Central Venous

More information

How and why I give IV fluid Disclosures SCA Fluids and public health 4/1/15. Andrew Shaw MB FRCA FCCM FFICM

How and why I give IV fluid Disclosures SCA Fluids and public health 4/1/15. Andrew Shaw MB FRCA FCCM FFICM How and why I give IV fluid Andrew Shaw MB FRCA FCCM FFICM Professor and Chief Cardiothoracic Anesthesiology Vanderbilt University Medical Center 2015 Disclosures Consultant for Grifols manufacturer of

More information

Review Article Can Transthoracic Echocardiography Be Used to Predict Fluid Responsiveness in the Critically Ill Patient? A Systematic Review

Review Article Can Transthoracic Echocardiography Be Used to Predict Fluid Responsiveness in the Critically Ill Patient? A Systematic Review Critical Care Research and Practice Volume 2012, Article ID 513480, 9 pages doi:10.1155/2012/513480 Review Article Can Transthoracic Echocardiography Be Used to Predict Fluid Responsiveness in the Critically

More information

Dr. F Javier Belda Dept. Anesthesiology and Critical Care Hospital Clinico Universitario Valencia (Spain) Pulsion MAB

Dr. F Javier Belda Dept. Anesthesiology and Critical Care Hospital Clinico Universitario Valencia (Spain) Pulsion MAB State of the Art Hemodynamic Monitoring III CO, preload, lung water and ScvO2 The winning combination! Dr. F Javier Belda Dept. Anesthesiology and Critical Care Hospital Clinico Universitario Valencia

More information

Assessment of loading conditions with cardiac ultrasound. A comprehensive review

Assessment of loading conditions with cardiac ultrasound. A comprehensive review REVIEWS Anaesthesiology Intensive Therapy 2015, vol. 47, no 5, XXX XXX ISSN 1642 5758 10.5603/AIT.a2015.0068 www.ait.viamedica.pl Assessment of loading conditions with cardiac ultrasound. A comprehensive

More information

Editor s key points. Y. Song 1,2, Y. L. Kwak 1,2,3, J. W. Song 1,2, Y. J. Kim 1 and J. K. Shim 1,2 *

Editor s key points. Y. Song 1,2, Y. L. Kwak 1,2,3, J. W. Song 1,2, Y. J. Kim 1 and J. K. Shim 1,2 * British Journal of Anaesthesia 113 (1): 61 6 (2014) Advance Access publication 9 April 2014. doi:10.1093/bja/aeu057 Respirophasic carotid artery peak velocity variation as a predictor of fluid responsiveness

More information

Surviving Sepsis Campaign. Guidelines for Management of Severe Sepsis/Septic Shock. An Overview

Surviving Sepsis Campaign. Guidelines for Management of Severe Sepsis/Septic Shock. An Overview Surviving Sepsis Campaign Guidelines for Management of Severe Sepsis/Septic Shock An Overview Mechanical Ventilation of Sepsis-Induced ALI/ARDS ARDSnet Mechanical Ventilation Protocol Results: Mortality

More information

Department of Medicine, Division of Pulmonary and Critical Care Medicine, Eastern Virginia Medical School, Norfolk, VA, USA

Department of Medicine, Division of Pulmonary and Critical Care Medicine, Eastern Virginia Medical School, Norfolk, VA, USA of 13 5/17/2011 11:48 PM www.medscape.com Authors and Disclosures Paul E. Marik, MD, FCCM, FCCP Department of Medicine, Division of Pulmonary and Critical Care Medicine, Eastern Virginia Medical School,

More information

Fluids in Sepsis Less is more. Dr Anand Senthi Joondalup Health Campus ED MBBS, MAppFin, GradCertPubHlth,

Fluids in Sepsis Less is more. Dr Anand Senthi Joondalup Health Campus ED MBBS, MAppFin, GradCertPubHlth, Fluids in Sepsis Less is more Dr Anand Senthi Joondalup Health Campus ED MBBS, MAppFin, GradCertPubHlth, FRACGP @drsenthi Summary Discussion of the evidence for/against fluid resuscitation in septic shock

More information

Department of General Medicine, Kilpauk Medical College and Hospital, Chennai, Tamil Nadu, India * Corresponding author

Department of General Medicine, Kilpauk Medical College and Hospital, Chennai, Tamil Nadu, India * Corresponding author Original Research Article Study on clinical assessment of volume status and correlation to the respiratory variation in inferior vena cava diameter by echocardiography, a non-invasive method of measuring

More information

Echocardiography can noninvasively

Echocardiography can noninvasively Bedside echocardiography in the assessment of the critically ill Yanick Beaulieu, MD, FRCPC Advances in ultrasound technology continue to enhance its diagnostic applications in daily medical practice.

More information

Key words: hand-carried ultrasound; mechanical ventilation; pulse pressure variation

Key words: hand-carried ultrasound; mechanical ventilation; pulse pressure variation Original Research CRITICAL CARE MEDICINE Radial Artery Pulse Pressure Variation Correlates With Brachial Artery Peak Velocity Variation in Ventilated Subjects When Measured by Internal Medicine Residents

More information

Transthoracic Echocardiography:

Transthoracic Echocardiography: Transthoracic Echocardiography: An essential tool for the obstetric anaesthetist? Brendan Carvalho MBBCh, FRCA Department of Anesthesiology Stanford University, California Focused TTE Stethoscope of the

More information

Doppler echocardiography in shocked patients

Doppler echocardiography in shocked patients REVIEW C URRENT OPINION Doppler echocardiography in shocked patients Xavier Repessé a,b, Laurent Bodson a,b, and Antoine Vieillard-Baron a,b Purpose of review To reiterate the necessity of integrating

More information

Cardiac Output Monitoring - 6

Cardiac Output Monitoring - 6 Cardiac Output Monitoring - 6 How to use Wrexham s Cardiac Output Monitors. Wrexham Maelor Critical Care Version 02.05.16 Introduction Types of Devices: NICOM - Cheetah Oesophageal Doppler +/- Pulse Contour

More information

Fluids in Sepsis: How much and what type? John Fowler, MD, FACEP Kent Hospital, İzmir Eisenhower Medical Center, USA American Hospital Dubai, UAE

Fluids in Sepsis: How much and what type? John Fowler, MD, FACEP Kent Hospital, İzmir Eisenhower Medical Center, USA American Hospital Dubai, UAE Fluids in Sepsis: How much and what type? John Fowler, MD, FACEP Kent Hospital, İzmir Eisenhower Medical Center, USA American Hospital Dubai, UAE In critically ill patients: too little fluid Low preload,

More information

Response to Fluid Boluses in the Fluid and Catheter Treatment Trial

Response to Fluid Boluses in the Fluid and Catheter Treatment Trial [ Original Research Critical Care ] Response to Fluid Boluses in the Fluid and Catheter Treatment Trial Matthew R. Lammi, MD ; Brianne Aiello, MD ; Gregory T. Burg, MD ; Tayyab Rehman, MD ; Ivor S. Douglas,

More information

Fluid Responsiveness Monitoring In Surgical and Critically Ill Patients

Fluid Responsiveness Monitoring In Surgical and Critically Ill Patients Fluid Responsiveness Monitoring In Surgical and Critically Ill Patients Clinical Impact of Goal-Directed Therapy Release Date: September 1, 2010 Expiration Date: September 30, 2011 Needs Statement Volume

More information

Recent Advances in Chest Medicine

Recent Advances in Chest Medicine Recent Advances in Chest Medicine Fluid Therapy in Resuscitated Sepsis* Less Is More Lakshmi Durairaj, MD; and Gregory A. Schmidt, MD, FCCP Fluid infusion may be lifesaving in patients with severe sepsis,

More information

Patient Safety Safe Table Webcast: Sepsis (Part III and IV) December 17, 2014

Patient Safety Safe Table Webcast: Sepsis (Part III and IV) December 17, 2014 Patient Safety Safe Table Webcast: Sepsis (Part III and IV) December 17, 2014 Presenters Mark Blaney, RN Regional Nurse Educator CHI Franciscan Health Karen Lautermilch Director, Quality & Performance

More information

SHOCK. Emergency pediatric PICU division Pediatric Department Medical Faculty, University of Sumatera Utara H. Adam Malik Hospital

SHOCK. Emergency pediatric PICU division Pediatric Department Medical Faculty, University of Sumatera Utara H. Adam Malik Hospital SHOCK Emergency pediatric PICU division Pediatric Department Medical Faculty, University of Sumatera Utara H. Adam Malik Hospital 1 Definition Shock is an acute, complex state of circulatory dysfunction

More information

Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock: 2016

Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock: 2016 Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock: 2016 Mitchell M. Levy MD, MCCM Professor of Medicine Chief, Division of Pulmonary, Sleep, and Critical Care

More information

Case Report Asymptomatic Pulmonary Vein Stenosis: Hemodynamic Adaptation and Successful Ablation

Case Report Asymptomatic Pulmonary Vein Stenosis: Hemodynamic Adaptation and Successful Ablation Case Reports in Cardiology Volume 2016, Article ID 4979182, 4 pages http://dx.doi.org/10.1155/2016/4979182 Case Report Asymptomatic Pulmonary Vein Stenosis: Hemodynamic Adaptation and Successful Ablation

More information

PCV and PAOP Old habits die hard!

PCV and PAOP Old habits die hard! PCV and PAOP Old habits die hard! F Javier Belda MD, PhD Head of Department Associate Professor Anaesthesia and Critical Care Hospital Clínico Universitario Valencia (SPAIN) An old example TOBACO SMOKING

More information

Goal-directed vs Flow-guidedresponsive

Goal-directed vs Flow-guidedresponsive Goal-directed vs Flow-guidedresponsive therapy S Magder Department of Critical Care, McGill University Health Centre Flow-directed vs goal directed strategy for management of hemodynamics S Magder Curr

More information

Functional Hemodynamic Monitoring and Management A practical Approach

Functional Hemodynamic Monitoring and Management A practical Approach Functional Hemodynamic Monitoring and Management A practical Approach Daniel A. Reuter Center of Anesthesiology and Intensive Care Medicine Hamburg-Eppendorf University Hospital Hamburg, Germany Euronaesthesia

More information

Surviving Sepsis Campaign Guidelines 2012 & Update for David E. Tannehill, DO Critical Care Medicine Mercy Hospital St.

Surviving Sepsis Campaign Guidelines 2012 & Update for David E. Tannehill, DO Critical Care Medicine Mercy Hospital St. Surviving Sepsis Campaign Guidelines 2012 & Update for 2015 David E. Tannehill, DO Critical Care Medicine Mercy Hospital St. Louis Be appropriately aggressive the longer one delays aggressive metabolic

More information

Original Research Article

Original Research Article ASSESSMENT AND COMPARISON OF CARDIAC FUNCTION AND VOLUME STATUS USING BEDSIDE ECHOCARDIOGRAPHY IN CRITICALLY ILL PATIENTS WITH OTHER CONVENTIONAL METHODS Priyanka Dwivedi, Shahbaz Ahmad, Vivek Pushp 3,

More information

Initial experience with Imacor htee-guided management of patients following transplant and mechanical circulatory support.

Initial experience with Imacor htee-guided management of patients following transplant and mechanical circulatory support. Thomas Jefferson University Jefferson Digital Commons Department of Cancer Biology Faculty Papers Department of Cancer Biology Fall 11-1-2012 Initial experience with Imacor htee-guided management of patients

More information

Bedside Ultrasound. US Guided Fluid Resuscitation. Michiel J. van Veelen, Emergency Physician, DTM&H

Bedside Ultrasound. US Guided Fluid Resuscitation. Michiel J. van Veelen, Emergency Physician, DTM&H Bedside Ultrasound US Guided Fluid Resuscitation Michiel J. van Veelen, Emergency Physician, DTM&H Outline Shock and Fluid Resuscitation in ICU Ultrasound in Shock Ultrasound Guided Fluid Resuscitation

More information

Troubleshooting Audio

Troubleshooting Audio Welcome! Audio for this event is available via ReadyTalk Internet Streaming. No telephone line is required. Computer speakers or headphones are necessary to listen to streaming audio. Limited dial-in lines

More information

The Hemodynamic Puzzle

The Hemodynamic Puzzle The Hemodynamic Puzzle SVV NIRS O 2 ER Lactate Energy Metabolism (Oxygen Consumption) (Ml/min/m 2 ) Oxygen Debt: To Pay or Not to Pay? Full Recovery Possible Delayed Repayment of O 2 Debt Oxygen Deficit

More information

Adult Echocardiography Examination Content Outline

Adult Echocardiography Examination Content Outline Adult Echocardiography Examination Content Outline (Outline Summary) # Domain Subdomain Percentage 1 2 3 4 5 Anatomy and Physiology Pathology Clinical Care and Safety Measurement Techniques, Maneuvers,

More information

Das recht Ventrikel ist auch noch da! RV function The RV operates as. Physiology Not very sensitive to preload Good compliance of the free wall

Das recht Ventrikel ist auch noch da! RV function The RV operates as. Physiology Not very sensitive to preload Good compliance of the free wall Das recht Ventrikel ist auch noch da! I.Michaux Intensive Care Medicine University Hospital CHU UCL Namur Mont-Godinne Belgium RV function The RV operates as a low pressure, volume pump, moving the blood

More information

Appendix II: ECHOCARDIOGRAPHY ANALYSIS

Appendix II: ECHOCARDIOGRAPHY ANALYSIS Appendix II: ECHOCARDIOGRAPHY ANALYSIS Two-Dimensional (2D) imaging was performed using the Vivid 7 Advantage cardiovascular ultrasound system (GE Medical Systems, Milwaukee) with a frame rate of 400 frames

More information

Response to questions at ACCA Webinar on Echocardiography in Critical Care

Response to questions at ACCA Webinar on Echocardiography in Critical Care Response to questions at ACCA Webinar on Echocardiography in Critical Care The participants in the Webinar were Bernard Cosyns [Professor of Cardiology at the Free University, Brussels, Belgium, and Chairman

More information

Research Article Haemodynamic Monitoring in the Intensive Care Unit: Results from a Web-Based Swiss Survey

Research Article Haemodynamic Monitoring in the Intensive Care Unit: Results from a Web-Based Swiss Survey BioMed Research International, Article ID 129593, 9 pages http://dx.doi.org/10.1155/2014/129593 Research Article Haemodynamic Monitoring in the Intensive Care Unit: Results from a Web-Based Swiss Survey

More information

Making the Case For Less Invasive Flow Based Parameters: APCO + SVV. Patricia A. Meehan, RN, MS, CCRN (a) Education Consultant Edwards Lifesciences

Making the Case For Less Invasive Flow Based Parameters: APCO + SVV. Patricia A. Meehan, RN, MS, CCRN (a) Education Consultant Edwards Lifesciences Making the Case For Less Invasive Flow Based Parameters: APCO + SVV Patricia A. Meehan, RN, MS, CCRN (a) Education Consultant Edwards Lifesciences A New Gold Standard? How does the system work? Sensor

More information

Predicting preload responsiveness using simultaneous recordings of inferior and superior vena cavae diameters

Predicting preload responsiveness using simultaneous recordings of inferior and superior vena cavae diameters Charbonneau et al. Critical Care 2014, 18:473 RESEARCH Open Access Predicting preload responsiveness using simultaneous recordings of inferior and superior vena cavae diameters Hélène Charbonneau 1,2,6*,

More information

Point of Care Ultrasound in the ICU

Point of Care Ultrasound in the ICU Point of Care Ultrasound in the ICU JENNIFER P. KANAAN, M.D. ASSISTANT PROFESSOR OF MEDICINE UNIVERSITY OF CONNECTICUT I have no disclosures 1 Ultrasound Ultrasound imaging is among the fastest, safest

More information

Should we measure the central venous pressure to guide fluid management? Ten answers to 10 questions

Should we measure the central venous pressure to guide fluid management? Ten answers to 10 questions De Backer and Vincent Critical Care (2018) 22:43 DOI 10.1186/s13054-018-1959-3 VIEWPOINT Should we measure the central venous pressure to guide fluid management? Ten answers to 10 questions Daniel De Backer

More information

Definition- study of blood flow Haemodynamic monitoring refers to monitoring of blood in the cardiovascular system Uses Is NB in the critically ill

Definition- study of blood flow Haemodynamic monitoring refers to monitoring of blood in the cardiovascular system Uses Is NB in the critically ill By Craig Definition- study of blood flow Haemodynamic monitoring refers to monitoring of blood in the cardiovascular system Uses Is NB in the critically ill pt Can assist diagnosis and decision making

More information

Hemodynamic Monitoring To Guide Volume Resuscitation

Hemodynamic Monitoring To Guide Volume Resuscitation Hemodynamic Monitoring To Guide Volume Resuscitation Nick Johnson, MD Acting Assistant Professor Division of Emergency Medicine Attending Physician, Medical & Neuro-Intensive Care Units Harborview Medical

More information

Reverse (fluid) resuscitation Should we be doing it? NAHLA IRTIZA ISMAIL

Reverse (fluid) resuscitation Should we be doing it? NAHLA IRTIZA ISMAIL Reverse (fluid) resuscitation Should we be doing it? NAHLA IRTIZA ISMAIL 65 Male, 60 kg D1 in ICU Admitted from OT intubated Diagnosis : septic shock secondary to necrotising fasciitis of the R lower limb

More information

Index. Note: Page numbers of article titles are in boldface type.

Index. Note: Page numbers of article titles are in boldface type. Note: Page numbers of article titles are in boldface type. A Abdomen, and aorta, as causes of shock, point-of-care ultrasonography in assessment of, 915 917 Abdominal compartment syndrome, trauma patient

More information

JFICMI Basic Critical Care Echocardiography (BCCE)

JFICMI Basic Critical Care Echocardiography (BCCE) JFICMI Basic Critical Care Echocardiography (BCCE) 2017 Introduction The International expert statement on training standards for critical care ultrasonography position paper published in Intensive Care

More information

Obligatory joke. The case for why it matters. Sepsis: More is more. Goal-Directed Fluid Resuscitation 6/1/2013

Obligatory joke. The case for why it matters. Sepsis: More is more. Goal-Directed Fluid Resuscitation 6/1/2013 Obligatory joke Keep your eye on the food. Goal-Directed Fluid Resuscitation Christopher G. Choukalas, MD, MS Department of Anesthesia and Perioperative Care University of California, San Francisco The

More information

CHEST. The cornerstone of treating patients with shock. Original Research

CHEST. The cornerstone of treating patients with shock. Original Research CHEST The Use of Bioreactance and Carotid Doppler to Determine Volume Responsiveness and Blood Flow Redistribution Following Passive Leg Raising in Hemodynamically Unstable Patients Paul E. Marik, MD ;

More information