Novatech Products for Interventional Pulmonology
|
|
- Kelley Perry
- 5 years ago
- Views:
Transcription
1 Novatech Products for
2 Novatech and Boston Medical Products Bringing you the finest products for Novatech is a manufacturer of top-quality medical products used successfully worldwide in the growing specialty of. Their original product, the DUMON Silicone Stent, has been helping treat patients since 1989, and continues to be the Gold Standard to which all other stents are compared. Boston Medical Products has been manufacturing specialized medical devices for head, neck, and tracheostomy applications since Boston Medical Products is the proud exclusive U.S. Distributor of Novatech products. This catalog features the flagship DUMON Silicone Stents, the largest range of models and sizes in the world, along with the TONN NOVATECH Stent Applicator System. Novatech and Boston Medical Products share a common vision to develop tailored medical devices to give patients a better quality of life. To this end, we are in constant communication with physicians, nurses, healthcare professionals, and patients themselves, striving to improve our existing products and to develop new products. We are aware of the need for individual solutions, so please contact us if you need special customization of our existing designs. For additional information and to see other exciting products from Novatech and Boston Medical Products, please visit. Manufactured by Exclusive U.S. Distributor Page 2
3 Content DUMON Tracheobronchial silicone stents, Tracheal Stent...7, Thin Tracheal Stent...8 DUMON ST, Hourglass Stent...9, Bronchial Stent DUMON Y, Bifurcation Stent Instruments TONN NOVATECH Tracheal and Bronchial Stent Applicator DUTAU Forceps SURVAC Suction Catheters NOVATECH is a registered trademark of Novatech SA in the USA, Europe, and other countries. DUMON is a trademark of Novatech SA. Page 3
4 Tracheobronchial Silicone Stents Novatech DUMON Products for DUMON ST DUMON Y DUMON Renowned for decades Since 1989, Novatech has been manufacturing the patented DUMON silicone stent a stent system that has been tried-and-tested to improve patient comfort. DUMON stents are made of specially treated medical grade transparent or radiopaque silicone (implantable for more than 29 days). They are considered the golden standard to which all others should be compared 1. 1 Bolliger, Pulmonary Reviews, Oct Indications Maintaining airway patency after desobstruction or dilation of a stenosis, in particular in the following cases: tracheobronchial tumors tracheobronchial stenoses with scarring tracheobronchial stenoses after anastomosis, resection or lung transplantation diameter reduction from intraluminal, extraluminal and intramural changes Page 4
5 Features Large collection for perfect adaption The key condition for perfect tolerance of the stents is to use a stent which is perfectly adapted to the patient s needs. For this reason and in order to be prepared for any situation, it is essential to provide the physician with a basic line of different stent types, diameters and lengths. The stents must not be cut in order to avoid the risk of granulation and to ensure transport of secretion (please refer to the Instructions for Use). Anti-migration stud system Depending on the design, there are 2, 3 or 4 lines of studs on the stent outside. The stud design minimizes the risk of migration of the stent by fixing it between the cartilaginous rings of the tracheo-bronchial tree. The stent design inhibits cough reflexes. The studs reduce direct contact between the stent surface and the mucosa and distribute compressive forces evenly among the small stud surfaces. Non-adherent smooth surface The stent inside is treated with a silicone-based layer which makes the surface anti-adherent, minimizing the risk of obstructions and improving the transport of secretion. The stent surface is excellently tolerated by the mucosa. Bevelled ends The ends of the stents are designed to reduce the risk of mucus accumulation. They are specially bevelled to be atraumatic and to improve the transport of secretion. Unrestricted implant-grade silicone (over 29 days) Easy placement The stents can be placed easily with the TONN NOVATECH stent applicator via rigid bronchoscopy. Easy removal The stents can be removed easily by grasping them with rigid forceps and pulling them into a rigid bronchoscope. NOVATECH and LOT imprinted on transparent stents with a diameter of 10 mm or larger Specially bevelled ends Page 5
6 DUMON The different types of stents Designation Type Wall Thickness (mm) Rows of Studs Tracheal Stent Thin Tracheal Stent 1.0 DUMON ST Hourglass Stent particularly for post-intubation stenoses 4 ( = 20 mm: 3) Bronchial Stent DUMON Y Bifurcation Stent The above mentioned stents are available as standard stents, in a large variety of sizes (see chart below). Other sizes and types are available as custom made stents. Stent Size Guide DUMON TD / DUMON TF / DUMON BD Determine the stent length (length of stenosis + 10 mm) and the stent diameter to choose from the available stents. Length (mm) g OD (mm) i This chart comprises only straight stents. For sizes of DUMON Y and DUMON ST, please refer to the respective catalog page. Page 6
7 Tracheal Stents are Novatech s standard endotracheal stents, with a wall thickness of 1.5 mm. Features Available in either transparent or radiopaque Non-adherent smooth surface Anti-migration stud system Bevelled ends Removability Unrestricted implant-grade silicone TD stent in situ transparent Length (mm) g OD (mm) i Custom made stents available. Please contact customer service. radiopaque Length (mm) g OD (mm) i R 03021R 03041R 03061R 03081R 03101R R 03141R 03161R 03181R 03201R 03221R 03231R R 03281R 03301R 03321R 03341R R 03401R 03421R 03441R 03461R R 03531R 03541R 03551R 03561R 03571R 03581R 03591R 03491R 03501R R 03641R 03661R 03681R 03701R 04281R 04291R 04301R 04311R R 04141R 04151R Custom made stents available. Please contact customer service. Page 7
8 Thin Tracheal Stents Endotracheal stents have a wall thickness of only 1.0 mm, which makes larger stent-diameters possible. Enhanced respiratory flow The larger inner diameter of a stent significantly enhances respiratory flow. For a standard tracheal stent of 50 mm in length and 16 mm in external diameter, the inner diameter increases by approx. 6 %, resulting in an increase of the luminal volume of 16 %. Improved transport of secretion The thinner walls of stents facilitate the internal movements of the trachea (respiration, ease of the peristaltic movements of the esophagus). This dynamic stent concept allows better transport of secretion (depending on mucus viscosity). Features Available in either transparent or radiopaque Non-adherent smooth surface Anti-migration stud system Bevelled ends Removability Unrestricted implant-grade silicone transparent Length (mm) g OD (mm) i F 03161F F 03281F 03301F 03321F 03341F F 03401F 03421F 03441F 03461F F 03661F 03681F 03701F 04281F 04291F 04301F F 04151F 04161F 04171F 04181F 04191F 04201F F 04241F 04251F 04261F 04271F 04431F 04441F 04451F Custom made stents available. Please contact customer service. radiopaque Length (mm) g OD (mm) i FR 03281FR 03301FR 03321FR 03341FR FR 03401FR 03421FR 03441FR 03461FR FR 03661FR 03681FR 03701FR 04281FR 04291FR 04301FR FR 04451FR Custom made stents available. Please contact customer service. Page 8
9 DUMON ST Hourglass Stents DUMON ST were designed in collaboration with Prof. Vergnon (Saint Etienne University Hospital, France). They are especially adapted to complex benign stenoses post intubation stenoses post tracheostomy stenoses subglottic stenoses. DUMON ST Easy to place after laser resection or dilatation, this stent is designed to avoid the risk of migration inherent to compression reduction. No migration was observed in a study covering a follow-up period of two years. With a mean dwell time of 19.6 months, even a curative effect has been observed in 4 of 13 patients. 1 The diameters of the distal and proximal ends correspond to the size of the healthy trachea. The central part is narrower, reducing the risk of traumatizing the stenotic part of the trachea while maintaining a sufficient lumen for the airflow and thus reducing the risk of restenosis. The ST was developed in cooperation with Prof. Vergnon, France, especially for treatment of benign tracheal stenosis such as post-intubation stenosis in the proximal part of the trachea. In some cases, placement of an ST-Stent can help prevent a tracheostomy. 2 Features Available in either transparent or radiopaque Non-adherent smooth surface Anti-migration stud system Bevelled ends Removability Unrestricted implant-grade silicone L 1 OD 1 1 Pr Jean-Michel Vergnon, CHEST 2000; 118: Pr Jean-Michel Vergnon, Efficacy and Tolerance of a New Silicone Stent for the Treatment of Benign Tracheal Stenosis. CHEST 2000 L 2 OD 2 L 3 OD 3 DUMON ST transparent DUMON ST radiopaque Dimensions (mm) REF OD Lengths Wall L1 L2 L3 Thickness Custom made stents available. Please contact customer service. Dimensions (mm) REF OD Lengths Wall L1 L2 L3 Thickness 09041R R R R R Custom made stents available. Please contact customer service. Page 9
10 Bronchial Stents stents have been developed for bronchial indications. The stent design corresponds to the smaller bronchi diameters and ensures optimal ventilation of the patient. Improved transport of secretion The 1.0 mm thin walls of stents facilitate the internal move ments of the trachea (respiration, ease of the peristaltic movements of the esophagus). This dynamic stent concept allows better transport of secretion (depending on mucus viscosity). Stent in situ Features Available in either transparent or radiopaque Non-adherent smooth surface Anti-migration stud system Bevelled ends Removability Unrestricted implant-grade silicone transparent Length (mm) g OD (mm) i Custom made stents available. Please contact customer service. radiopaque Length (mm) g OD (mm) i R 04341R 04371R 04391R 04411R 04421R R 03741R 03761R 03781R 03801R 03821R R 03861R 03881R 03901R 03921R R 03981R 04001R 04021R 04041R 04051R Custom made stents available. Please contact customer service. Page 10
11 DUMON Y Bifurcation Stents DUMON Y stents have 3 rows of studs. The posterior side has no studs in order to avoid trauma of the tracheo-esophageal wall. The branches are angled according to anatomy. Custom lengths and diameters are available on request. DUMON Y stents may be modified by Novatech in order to allow airflow to the right upper lobe. DUMON Y A closed right branch stem for pneumonectomized patients with a fistula is available on a custom basis. outer diameter 1 L1 Features Available in transparent only Reduced pressure to the posterior tracheal mucosa Easy placement with TONN NOVATECH stent applicator Anti-migration stud system Non-adherent smooth surface Bevelled ends Removability Unrestricted implant-grade silicone L2 L3 outer diameter outer diameter 3 DUMON Y transparent REF Dimensions (mm) OD Lengths Wall L1 L2 L3 Thickness Custom made stents available. Please contact customer service. 1.0 Page 11
12 TONN NOVATECH Tracheal and Bronchial Stent Applicator basic block pusher clamping rod folding device loading rod introducer tube Developed by Dr. Tonn (Hanover, Germany), the TONN NOVATECH tracheal and bronchial Stent Applicator facilitates the placement of Novatech s tracheobronchial DUMON stents through a rigid bronchoscope. Easy to handle, the TONN NOVATECH Stent Applicator is available in four sizes (BLUE, RED, GREEN and WHITE) allowing the insertion of silicone stents in a wide range of sizes: Stents with an outer diameter of up to 20 mm and a length of up to 160 mm (Y-Stents) can be placed. Furthermore Y-Stent insertion is facilitated. The correct position of the branches for the left and the right bronchus is determined before insertion, minimizing the risk of misplacement and stent damage. Page 12
13 TONN NOVATECH Tracheal and Bronchial Stent Applicator Color Introducer tube length (cm) Introducer tube OD (mm) BLUE BRS B 120 RED BRS R 130 GREEN BRS G 140 WHITE BRS W 150 Individual components available as spare parts. Please contact us for a quotation. REF Which applicator (BLUE, RED, GREEN, WHITE) is used for which DUMON stent? TD Length P P P P P P P 12 P P P P P P P 13 P P P P P P 14 P P P P P P 15 P P P P P P P P P P 16 P P P P P P P P P P 18 P P P TF Length P P 13 P P P P P 14 P P P P P 16 P P P P P P P 18 P P P P P P P 20 P P P P P P P P BD Length P P P P P P 10 P P P P P P 11 P P P P P 12 P P P P P P ST 12 P 14 P 15 P 16 P 18 P Y NB: Stents which can be placed with the BLUE system can also be placed with the RED system. For stents not appearing in the chart and/or for custom made stents, please contact our customer service. Page 13
14 DUTAU Forceps The DUTAU Forceps allows the physician to create a smooth fenestration in a NOVATECH DUMON silicone stent in order to adapt it to a specific situation (e.g. ventilation of the upper lobe). DUTAU Forceps REF Description Items per box 6522 DUTAU Forceps 1 Page 14
15 SURVAC Suction Catheters for bronchoscopy SURVAC are atraumatically rounded single use suction catheters for bronchoscopy. The PTFE-catheters are more flexible than the polycarbonate (PC) catheters. Due to their flexibility and their small diameter, the PT- FE-catheters are adapted to suctioning more distal parts of the tracheobronchial tree. The larger (3 4 mm) polycarbonate catheters are particularly suited for the axial aspiration of larger tumor parts or suctioning of large quantities in emergency cases. REF Description Diameter (mm) ID OD Length (cm) SURVAC PTFE SURVAC PC SURVAC PC SC SURVAC PC Connector Items per box female, PVC 50 Page 15
16 Manufactured by Exclusive U.S. Distributor To Place an Order Our Customer Service Representatives are available from 8:30 a.m. to 5:00 p.m. (EST) Monday through Friday. Orders can also be placed through our 24-hour fax line. Customer Service: (toll-free in the U.S.) Main Telephone: hour-Fax: Prescription Policy U.S. federal law restricts these products to sale by or on the order of a physician. Shipment Standard shipping within the U.S. is FedEx two-day delivery. Express orders are accepted until 3:00 p.m. (EST) for next business day delivery nationwide. Most orders are shipped the same day. Saturday delivery is available in many areas. Warranty Boston Medical Products, Inc. warrants that reasonable care has been used in the manufacturing of all products. All products are warranted to be free of defects at the time of shipment. For specific product warranties, please refer to individual product Instructions for Use. Return Policy Boston Medical Products, Inc. will accept returned items that are unopened in the original packaging. Please call Customer Service to obtain a Return Authorization. Returns accepted within 30 days from invoice date. A Return Authorization is required for all returns. All returns are subject to a restocking fee. Merchandise credit only. BMP-PCA-NOV Boston Medical Products, Inc. 70 Chestnut Street Shrewsbury, MA USA Tel. +1 (508) Fax +1 (508) info@bosmed.com
Rhinology Products. Rhinology Products. Superior solutions for superior patient care.
Rhinology Products Superior solutions for superior patient care. The Doyle Open-Lumen Splint addresses the problem of potential closure of the airway lumen by a hypertrophied turbinate. We also offer the
More informationDouble Y-stenting for tracheobronchial stenosis
ERJ Express. Published on April 10, 2012 as doi: 10.1183/09031936.00015012 Double Y-stenting for tracheobronchial stenosis M. Oki and H. Saka AFFILIATIONS Dept of Respiratory Medicine, Nagoya Medical Center,
More informationDUMON-NOVATECH Y-STENTS: A FOUR-YEAR EXPERIENCE WITH 50 TRACHEOBRONCHIAL TUMORS INVOLVING THE CARINA
Solunum 3, Özel Sayı 2: 260-264, 2001 DUMON-NOVATECH Y-STENTS: A FOUR-YEAR EXPERIENCE WITH 50 TRACHEOBRONCHIAL TUMORS INVOLVING THE CARINA Jean F DUMON* M C DUMON* SUMMARY This article reports a 4-year
More informationSince central airway stenosis is often a lifethreatening. Double Y-stenting for tracheobronchial stenosis. Masahide Oki and Hideo Saka
Eur Respir J 2012; 40: 1483 1488 DOI: 10.1183/09031936.00015012 CopyrightßERS 2012 Double Y-stenting for tracheobronchial stenosis Masahide Oki and Hideo Saka ABSTRACT: The purpose of the present study
More informationBr o n c h o s c o p e
Br y a n-du m o n Br y a n-du m o n Series II Rigid Br o n c h o s c o p e Product Catalog Diagnostic and Therapeutic Applications: Laser Therapy Silicone Stent Placement Foreign Body Removal Deep Biopsy
More information4/24/2017. Tracheal Stenosis. Tracheal Stenosis. Tracheal Stenosis. Tracheal Stenosis. Tracheal Stenosis Endoscopic & Surgical Management
Endoscopic & Surgical Management Pressure ulceration Healing: granulation cicatrization contraction Ann Surg 1969;169:334-348 Gary Schwartz, MD Department of Thoracic Surgery and Lung Transplantation Baylor
More informationcreating stability a bess group company Stents for Gastroenterology
a bess group company Stents for Gastroenterology a bess group company Page 2 CONTENTS aixstent self-expanding Nitinol stents aixstent OES Esophageal Stent... 6 aixstent OEL Esophageal Leakage Stent...
More informationAdvanced Bronchoscopy
Advanced Bronchoscopy Radial Jaw 4 Pulmonary Forceps Ultraflex Tracheobronchial Stent System CRE Pulmonary Balloon Alair Bronchial Thermoplasty Catheter CRE Pulmonary Balloon Radial Jaw 4 Pulmonary Forceps
More informationTherapeutic Bronchoscopy Etiology - Benign Stenosis Post - intubation Trauma Post - operative Inflammatory Idiopathic
Endobronchial Palliation of Airway Disease Douglas E. Wood, MD Professor and Chief Division of Cardiothoracic Surgery Vice-Chair, Department of Surgery Endowed Chair in Lung Cancer Research University
More informationThe use of metallic expandable tracheal stents in the management of inoperable malignant tracheal obstruction
The use of metallic expandable tracheal stents in the management of inoperable malignant tracheal obstruction Alaa Gaafar-MD, Ahmed Youssef-MD, Mohamed Elhadidi-MD A l e x a n d r i a F a c u l t y o f
More informationTelescopic Bronchoscopy via Laryngoscope
Telescopic Bronchoscopy via Laryngoscope New Technique By Amr Hegab MS,FRCS,MD Head of Department of Otolaryngology,Head/Neck & Skull Base Surgery Maadi Armed Forces Hospital Cairo - Egypt Silver Jubilee
More informationTracheostomy/ Laryngectomy PRODUCT CATALOG
1 Tracheostomy/ Laryngectomy PRODUCT CATALOG 2 3 is a highly experienced manufacturer of medical devices for tracheostomized and laryngectomized patients. For many years we have been supplying our customers
More informationColonic Metal Stents MAKING A DIFFERENCE TO HEALTH
Colonic Metal Stents In a fast paced and maturing market, Diagmed Healthcare s Hanarostent has managed to continue to innovate and add unique and clinically superior features to its already premium range.
More informationSTANDARD TRACHEOSTOMY TUBE Better comfort and increased safety for the patient and healthcare provider.
RUSCH CRYSTALCLEARHORIZON PLUS TRACHEOSTOMY LIGATION SYSTEM SET Better comfort and increased safety The for name the you patient know, and the healthcare product provider. you trust. RUSCH CRYSTALCLEAR
More informationAERO DV Tracheobronchial Direct Visualization Stent System
AERO DV Tracheobronchial Direct Visualization Stent System Review Instructions For Use Before Using This System. Single Use Only Non-sterile MR Conditional CONTENTS Instructions for Use...............................
More informationAIRWAY MANAGEMENT SOLUTIONS
KAPITEX HEALTHCARE - SPECIALIST KNOWLEDGE, SUPPORT AND CARE AIRWAY MANAGEMENT SOLUTIONS Specialist tracheostomy management solutions you can trust Kapitex - Adding Quality of Life to Airway Management
More informationBiliary Metal Stents MAKING A DIFFERENCE TO HEALTH
Biliary Metal Stents In a fast paced and maturing market, Diagmed Healthcare s Hanarostent has managed to continue to innovate and add unique and clinically superior features to its already premium range.
More informationMontgomery T-tube placement in the treatment of benign tracheal lesions
European Journal of Cardio-thoracic Surgery 36 (2009) 352 356 www.elsevier.com/locate/ejcts Montgomery T-tube placement in the treatment of benign tracheal lesions Angelo Carretta *, Monica Casiraghi,
More informationTRACHEOSTOMY. Tracheostomy means creation an artificial opening in the trachea with tracheostomy tube insertion
TRACHEOSTOMY Definition Tracheostomy means creation an artificial opening in the trachea with tracheostomy tube insertion Indications for tracheostomy 1-upper airway obstruction with stridor, air hunger,
More informationTracheal Trauma: Management and Treatment. Kosmas Iliadis, MD, PhD, FECTS
Tracheal Trauma: Management and Treatment Kosmas Iliadis, MD, PhD, FECTS Thoracic Surgeon Director of Thoracic Surgery Department Hygeia Hospital, Athens INTRODUCTION Heterogeneous group of injuries mechanism
More informationSection 4.1 Paediatric Tracheostomy Introduction
Bite- sized training from the GTC Section 4.1 Paediatric Tracheostomy Introduction This is one of a series of bite- sized chunks of educational material developed by the Global Tracheostomy Collaborative.
More informationTherapeutic bronchoscopy for malignant airway stenoses: Choice of modality and survival
Original Article Free full text available from www.cancerjournal.net Therapeutic bronchoscopy for malignant airway stenoses: Choice of modality and survival ABSTRACT Background: There are no data regarding
More informationwith Blom-Singer Gel Cap Insertion System
with Blom-Singer Gel Cap Insertion System MEDICAL PROFESSIONAL Instructions For Use R2 37269-02G 37269-02G Effective January 2016 Blom-Singer and InHealth Technologies are registered trademarks of Freudenberg
More informationRota-Trach Double Lumen Tracheostomy Tube VITALTEC
Rota-Trach Double Lumen Tracheostomy Tube VITALTEC Contents INTRODUCTION HISTORY REVIEW ANATOMY & PHYSIOLOGY OPERATIVE PROCEDURE THE RANGE OF TRACHEOSTOMY TUBES ROTA-TRACH TRACHEOSTOMY TUBE INTRODUCTION
More informationInterventional Pulmonology
Interventional Pulmonology The Division of Thoracic Surgery Department of Cardiothoracic Surgery New York Presbyterian/Weill Cornell Medical College p: 212-746-6275 f: 212-746-8223 https://weillcornell.org/eshostak
More informationST-513-S ST-514-S 15ST-515-S
Urmee Healthcare G-1, sho Plalav, (Jwala Estate), Opp. Flyover ridge, S. V. Road, orivali (W), Mumbai - 0 02. INDI +1 22 2 1, 4 5 Telefax : +1 22 2053 Email : deena@vsnl.com LRYNGOLOGY Hood Tracheal T-Tube
More informationIntravascular Ultrasound (IVUS) and Optical Coherence Tomography (OCT)
Intravascular Ultrasound (IVUS) and Optical Coherence Tomography (OCT) Clare McLaren Great Ormond Street Hospital London Introduction IVUS and OCT supplementary techniques to angiography provide information
More informationTERMS & CONDITIONS OF SALE
TERMS & CONDITIONS OF SALE PLACING YOUR ORDER WITH TM For your convenience you can fax your order to: (904) 886-9517 for processing. -or- Check us out and order online at www.invotec.net We will ship ground
More informationBryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL
Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL Table of Contents Bryan-DUmon Series II rigid bronchoscope 1. 2. 3. 4. 5. Diagram and Overview Universal Barrel Bronchial and
More informationFull Range of Tracheostomy Solutions
Full Range of Tracheostomy Solutions Every Breath Counts Choices by Setting Throughout the hospital or home Smiths Medical tracheostomy tubes are designed for performance ER The Portex Cricothyroidotomy
More informationTranslaryngeal tracheostomy
Translaryngeal tracheostomy Issued: August 2013 NICE interventional procedure guidance 462 guidance.nice.org.uk/ipg462 NICE has accredited the process used by the NICE Interventional Procedures Programme
More informationJay B. Brodsky, M.D. Professor Department of Anesthesia tel: (650) Stanford University School of Medicine fax: (650)
Jay B. Brodsky, M.D. Professor Department of Anesthesia tel: (650) 725-5869 Stanford University School of Medicine fax: (650) 725-8544 Stanford, CA, 94305, USA e-mail: jbrodsky@stanford.edu RELIABLE SEPARATION
More informationExternal trauma (MVA, surf board, assault, etc.) Internal trauma (Endotracheal intubation, tracheostomy) Other
Etiology External trauma (MVA, surf board, assault, etc.) Internal trauma (Endotracheal intubation, tracheostomy) Other Systemic diseases (vasculitis, etc.) Chemo/XRT Idiopathic Trans nasal Esophagoscope
More informationAudra Fuller MD, Mark Sigler MD, Shrinivas Kambali MD, Raed Alalawi MD
Clinical Series Successful treatment of post-intubation tracheal stenosis with balloon dilation, argon plasma coagulation, electrocautery and application of mitomycin C Audra Fuller MD, Mark Sigler MD,
More informationCAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE
CAREFULLY READ ALL INSTRUCTIONS PRIOR TO USE INDICATIONS FOR USE The LATERA Absorbable Nasal Implant is indicated for supporting upper and lower lateral nasal cartilage. CAUTION: Federal law restricts
More informationGastric / EUS Metal Stents
Gastric / EUS Metal Stents In a fast paced and maturing market, Diagmed Healthcare s Hanarostent has managed to continue to innovate and add unique and clinically superior features to its already premium
More informationNeonatal Airway Disorders, Treatments, and Outcomes. Steven Goudy, MD Pediatric Otolaryngology Emory University Medical Center
Neonatal Airway Disorders, Treatments, and Outcomes Steven Goudy, MD Pediatric Otolaryngology Emory University Medical Center Disclosure I have nothing to disclose Neonatal and Pediatric Tracheostomy Tracheostomy
More informationBoston. Medical Products. laryngeal and esophageal products
Boston Medical Products laryngeal and Innovation, quality and service that define today s Gold Standards. The Montgomery Laryngeal Stent is a molded silicone prosthesis designed to conform to the normal
More informationAIRWAY MANAGEMENT PRODUCTS
QUICK REFERENCE GUIDE AIRWAY MANAGEMENT PRODUCTS Shiley Endotracheal Tubes SHILEY ENDOTRACHEAL TUBE CATALOG NUMBER CHARTS DESCRIPTION QTY PER BOX SIZE (MM) 1.0 1.5 2.0 2.5 3.0 3.5 4.0 VENTILATOR-ASSOCIATED
More informationTHE THE MORE MORE NATURAL APPROACH TO OPTIMAL FIT
THE THE MORE MORE NATURAL APPROACH Natural Approach TO Optimal Fit TO OPTIMAL FIT Conformability without Compromise THE STANDARD IN Conformability AND Designed for flexibility and conformability in tortuous
More informationRespiratory distress in patients with central airway obstruction
Indian J Thorac Cardiovasc Surg (2010) 26:151 156 DOI 10.1007/s12055-010-0021-0 ORIGINAL ARTICLE Respiratory distress in patients with central airway obstruction Mohamed Abdel Hamied Regal & Yasser Ahmed
More informationThe Hitch Stitch : An Effective Method of Preventing Migration in High Tracheal Stenosis
Interventional Pulmonology Respiration 2017;93:106 111 Received: July 6, 2016 Accepted after revision: November 3, 2016 Published online: December 17, 2016 The Hitch Stitch : An Effective Method of Preventing
More informationDESIGNED FOR DIFFICULT TRACHEAL OR ESOPHAGEAL INTUBATION
Airway Superglottic Kendall Combitube Esophageal/Tracheal Double Lumen Airway for Emergency or Difficult Intubation. Blind placement without laryngoscope Unique design provides patient airway with either
More informationAccess More Patients. Customize Each Seal.
Access More. Customize Each Seal. The Least Invasive Path Towards Proven Patency ULTRA LOW PROFILE TO EASE ADVANCEMENT The flexible, ultra-low 12F ID Ovation ix delivery system enables you to navigate
More informationVBM offers different Tube Fixations for Endotracheal Tubes (oral / nasal), Tracheostomy Tubes, Laryngeal Tubes or Laryngeal Masks.
VBM Tube Fixations VBM offers different Tube Fixations for Endotracheal Tubes (oral / nasal), Tracheostomy Tubes, Laryngeal Tubes or Laryngeal Masks. Application: Anesthesia Intensive Care (long-term intubation)
More informationAirway Remodeling: Preliminary Experience with Bio-Absorbable Airway Stents in Adults Jaus MO, Gonfiotti A, Barale D, Macchiarini P
Airway Remodeling: Preliminary Experience with Bio-Absorbable Airway Stents in Adults Jaus MO, Gonfiotti A, Barale D, Macchiarini P University Hospital Careggi Florence, Italy Disclosure Statement THE
More informationTracheal stenosis in infants and children is typically characterized
Slide Tracheoplasty for Congenital Tracheal Stenosis Peter B. Manning, MD Tracheal stenosis in infants and children is typically characterized by the presence of complete cartilaginous tracheal rings and
More informationZenith Renu AAA Converter Graft. Device Description Planning and Sizing Deployment Sequence Patient Follow-Up
Zenith Renu AAA Converter Graft Device Description Planning and Sizing Deployment Sequence Patient Follow-Up Device description: Device indications The Zenith Renu AAA Converter Graft with Z-Trak Introduction
More informationВосток-пром CATALOGUE INSEMINATION & IN VITRO FERTILIZATION КАТАЛОГ ИНСЕМИНАЦИЯ & РЕПРОДУКТИВНАЯ МЕДИЦИНА. медикал
CATALOGUE INSEMINATION & IN VITRO FERTILIZATION КАТАЛОГ ИНСЕМИНАЦИЯ & РЕПРОДУКТИВНАЯ МЕДИЦИНА Central HQ Karadžičová St. Nb 8-A 82108 Bratislava - SLOVAKIA Phone/Fax Land-line: +421 (0) 2 5939 6000 Fax:
More informationDisclosures. Learning Objectives. Coeditor/author. Associate Science Editor, American Heart Association
Tracheotomy Challenges for airway specialists Elizabeth H. Sinz, MD Professor of Anesthesiology & Neurosurgery Associate Dean for Clinical Simulation Disclosures Coeditor/author Associate Science Editor,
More informationImplantation of a self-expandable metallic inverted Y-stent to treat tracheobronchial stenosis in the carinal region: initial clinical experience
Implantation of a self-expandable metallic inverted Y-stent to treat tracheobronchial stenosis in the carinal region: initial clinical experience R. M. Yang a, X. W. Han a, b,g. Wu b, Y. D. Li b, F. B.
More informationEndobronchial Management of Benign, Malignant, and Lung Transplantation Airway Stenoses
Endobronchial Management of Benign, Malignant, and Lung Transplantation Airway Stenoses Joshua R. Sonett, MD, Robert J. Keenan, MD, Peter F. Ferson, MD, Bartley P. Griffith, MD, and Rodney J. Landreneau,
More informationTracheal Stenosis Following Cuffed Tube Tracheostomy
Tracheal Stenosis Following Cuffed Tube Tracheostomy Anatomical Variation and Selected Treatment Armand A. Lefemine, M.D., Kenneth MacDonnell, M.D., and Hyung S. Moon, M.D. ABSTRACT Tracheal stenosis resulting
More informationPetite Wound Drainage System. 13mm CWV Drainage System. CWSump. CWV with Trocar
CWVDrain Designed to assure optimum cosmetic results Tapered, hubless design provides atraumatic insertion and removal Internal ribs prevent collapsing or kinking Large 150cc capacity reservoir decreases
More informationSubject Index. Bacterial infection, see Suppurative lung disease, Tuberculosis
Subject Index Abscess, virtual 107 Adenoidal hypertrophy, features 123 Airway bleeding, technique 49, 50 Airway stenosis, see Stenosis, airway Anaesthesia biopsy 47 complications 27, 28 flexible 23 26
More informationUse of the Silicone T-tube to Treat Tracheal Stenosis or Tracheal Injury
Use of the Silicone T-tube to Treat Stenosis or Injury Chang-Jer Huang MD Backgound: stenosis or tracheal is a troublesome disease. Traditional temporary tracheostomy and reconstruction can resolve some
More informationCentral airway obstruction (CAO) : laser, APC, stents and other techniques.
Thank you for viewing this presentation. We would like to remind you that this material is the property of the author. It is provided to you by the ERS for your personal use only, as submitted by the author.
More informationPUR Tracheostomy Tubes
PUR Tracheostomy Tubes FreeVent long term/permanent tracheostomy tubes are designed to provide the user with a safe, comfortable and flexible tube that is easy to handle. FreeVent tubes come in a wide
More informationLARYNGOSCOPES/TRACHEASCOPES
NEW! Ossoff-Pilling Video Laryngoscope See page 34 for details. NEONATE/INFANT 521500 Holinger................................. 26 521550 Jackson.................................. 27 522002 Holinger.................................
More informationBalloon in Balloon (BIB )
Balloon in Balloon (BIB ) Stent Placement Catheter INSTRUCTIONS FOR USE CAUTION: FEDERAL (USA) LAW RESTRICTS THIS DEVICE TO SALE BY OR ON THE ORDER OF A PHYSICIAN. Read all instructions prior to use. Distributed
More informationMetallic stent and flexible bronchoscopy without fluoroscopy for acute respiratory failure
Eur Respir J 2008; 31: 1019 1023 DOI: 10.1183/09031936.00099507 CopyrightßERS Journals Ltd 2008 Metallic stent and flexible bronchoscopy without fluoroscopy for acute respiratory failure S-M. Lin*,#, T-Y.
More informationAnatomy and Physiology. The airways can be divided in to parts namely: The upper airway. The lower airway.
Airway management Anatomy and Physiology The airways can be divided in to parts namely: The upper airway. The lower airway. Non-instrumental airway management Head Tilt and Chin Lift Jaw Thrust Advanced
More informationSUBGLOTTIC SECRETION REMOVAL:
ARROW REGIONAL TELEFLEX ANAESTHESIA ISIS Nullan utpat, Better vulputpatie access. ero Best dion practice. ulputat SUBGLOTTIC SECRETION REMOVAL: A VAP REDUCTION STRATEGY Ventilator-Associated Pneumonia
More informationREF Page REF Page REF Page REF Page TRACOE percutan TRACOE technic TRACOE select TRACOE care TRACOE kids TRACOE vario TRACOE larynx TRACOE comfort
REF Numbers Overview REF Page TRACOE percutan 320 19 321 19 322 19 888-322 19 330 19 331 19 332 19 888-332 19 420 18 421 18 422 18 423 18 424 18 425 18 517 15 518 15 520 15 TRACOE vario 450 22 450-P 23
More informationChapter 124: Congenital Disorders of the Trachea. Bruce Benjamin
Chapter 124: Congenital Disorders of the Trachea Bruce Benjamin Investigation of the larynx and pharynx may be incomplete in infants and children with congenital abnormalities without investigation of
More informationEndorectal Balloon (ERB) Endorectal Balloon (ERB) Instructions for Use
Endorectal Balloon (ERB) Instructions for Use GRF-0004-00 Rev. 08 Page 1 of 9 Contents Instructions for Use... 3 Indications for Use... 3 Contraindications... 3 Storage... 4 Warnings... 4 Accessories Provided...
More informationTracheal Collapse: Medical Management Versus Implantable Stents
What is Tracheal Collapse? The trachea (windpipe) is a large tube that is reinforced by cartilage rings. The trachea runs alongside of the esophagus (food pipe) and delivers air to the lungs. Tracheal
More informationKapitex Healthcare. making things clearer for tracheostomy patients
Kapitex Healthcare making things clearer for tracheostomy patients preface In publishing this booklet, Kapitex Healthcare Ltd hopes to provide information and understanding for both the patient and carer
More informationA Proposed Grading System for Post-Intubation Tracheal Stenosis
Original Article 2012 NRITLD, National Research Institute of Tuberculosis and Lung Disease, Iran ISSN: 1735-0344 TANAFFOS A Proposed Grading System for Post-Intubation Tracheal Stenosis Ali Ghorbani 1,
More informationBronchoscopy SICU Protocol
Bronchoscopy SICU Protocol Updated January 2013 Outline Clinical indications Considerations Preparation Bronchoscopy technique Bronchoalveolar Lavage (BAL) Post-procedure Purpose Bronchoscopy is a procedure
More informationCP STENT. Large Diameter, Balloon Expandable Stent
CP STENT Large, Expandable CP STENT OPTIONS 12mm to Expansion 26mm to Expansion CP Matrix (number of zigs) 1.6 2.2 2.8 3.4 3.9 4.5 5 5.5 6 12 14 15 16 18 20 22 24 26 28 30 CP Details: CP is composed of
More informationDay 2 Pulmonary Breakout Interventional Pulmonology
Day 2 Pulmonary Breakout Interventional Pulmonology R. Paul Boesch, DO, MS Assistant Professor, Pulmonary Medicine Mayo Clinic Children s Center Interventional Pediatric Pulmonology or Pulm/ENT airway
More informationApplication of the Montgomery T-tube in subglottic tracheal benign stenosis
Surgical Technique pplication of the Montgomery T-tube in subglottic tracheal benign stenosis Huihui Hu, Jisong Zhang, Fengjie Wu, Enguo Chen Department of Respiratory and Critical Care Medicine, Sir Run
More informationDepartment of Thoracic Medicine, Chang Gung Memorial Hospital, Lin-Kuo Branch, Chang Gung Medical Foundation; Abstract
DOI 10.6314/JIMT.2017.28(4).07 2017 28 243-251 Impacts of Airway Self-expandable Metallic Stent on Ventilator Weaning and Survival of Mechanically Ventilated Patients with Esophageal Cancer and Cental
More informationDIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS
DIGESTIVE HEALTH ENTERAL FEEDING PRODUCTS HALYARD* MIC* AND MIC-KEY* INTRODUCER KITS HALYARD* MIC* and MIC-KEY* Introducer Kits provide physicians with an innovative solution to facilitate the primary
More informationSYMBOLOGY. = Manufacturer. = Manufacturing Serial Number. = Manufacturing Lot Number = Catalog Number LOT REF. = Do not resterilize Single Use Only
damage or expenses directly or indirectly arising from use of this product. This warranty is in lieu of and excludes all other warranties not expressly set forth herein, whether express or implied by operation
More informationWallFlex Biliary Metal Stents
WallFlex Biliary Metal Stents Please Note: These steps are intended to be for general guidance only. For complete instructions for use, indications, contraindications and warnings, please refer to the
More informationAirway stenosis: CT evaluation of endoscopic treatment
Airway stenosis: CT evaluation of endoscopic treatment Poster No.: C-0334 Congress: ECR 2012 Type: Scientific Exhibit Authors: N. Maggialetti, M. Ficco, A. A. A. Stabile Ianora, M. Moschetta, A. Scardapane,
More information2017 Coding & Payment Quick Reference
2017 Coding & Payment Quick Reference Select Pulmonary Procedures Payer policies will vary and should be verified prior to treatment for limitations on diagnosis, coding or site of service requirements.
More informationExtracorporeal Circuit Cannulae { VENOUS}
Extracorporeal Circuit Cannulae { VENOUS} Medtronic are designed to provide optimal venous drainage while providing flexibility and ease of use. We offer a variety of single stage venous cannulae with
More informationproduct catalogue Quality Results for life
product catalogue ET CATHETERS OPU NEEDLES Quality Results for life IUI CATHETERS OOCYTE RETRIEVAL NEEDLES NEEDLES oocyte retrieval needles Manufactured from steel of excellent quality, its triple cut
More informationCardiva Catalyst III INSTRUCTIONS FOR USE
Cardiva Catalyst III INSTRUCTIONS FOR USE IFU 2469 Rev. G CAUTION Federal (USA) law restricts this device to sale by or on the order of a physician. For single use only GRAPHICAL SYMBOLS ON THE CARDIVA
More informationFinally, the Control You Need to Deliver Accurate Treatment
Finally, the Control You Need to Deliver Accurate Treatment LIFESTREAM Covered Stent. has joined BD When you reach for a balloon expandable stent, you require accuracy. The LIFESTREAM Balloon Expandable
More information1 Chapter 40 Advanced Airway Management 2 Advanced Airway Management The advanced airway management techniques discussed in this chapter are to
1 Chapter 40 Advanced Airway Management 2 Advanced Airway Management The advanced airway management techniques discussed in this chapter are to introduce the EMT-B student to these procedures only. In
More informationi INTERACTIVE CATALOG FIND YOUR IDEAL CANNULAE
i INTERACTIVE CATALOG FIND YOUR IDEAL CANNULAE Catalog 2017 i USER TIPS Easily navigate through the pages in our 2017 Cannula Catalog by using the mini-menu shown on upper right of each page. Navigate
More informationTracheostomy and Ventilator Education Program Module 2: Respiratory Anatomy
Tracheostomy and Ventilator Education Program Module 2: Respiratory Anatomy Disclaimer This material is intended for use by trained family members and caregivers of children with tracheostomies who are
More informationPulmonary. Pulmonary Endoscopy. Alair Bronchial Thermoplasty System. Transbronchial Aspiration Needles. Cytology Brushes.
Pulmonary Endoscopy Alair Bronchial Thermoplasty System Alair Bronchial Thermoplasty System... 79 Airway Stents Dynamic (Y) Stent... 79 Polyflex Self-Expanding Silicone Airway Stent... 82 Ultraflex Partially
More informationWhere Therapy is Moving Monarch Airway Clearance System
Where Therapy is Moving Monarch Airway Clearance System Mobile therapy that works. 1,2,3 The Monarch Airway Clearance System is a high frequency chest wall oscillation (HFCWO) therapeutic device with revolutionary
More informationSteroid Therapy for Tracheal Stenosis in Children
Steroid Therapy for Tracheal Stenosis in Children Clinical Experience in 4 Children with Severe Strictures H. Biemann Othersen, Jr., M.D. ABSTRACT Recently a refinement in the treatment of tracheal stenosis
More informationChapter 40 Advanced Airway Management
1 2 3 4 5 Chapter 40 Advanced Airway Management Advanced Airway Management The advanced airway management techniques discussed in this chapter are to introduce the EMT-B student to these procedures only.
More informationP: (888) F: (888)
HOURS Customer Service is available between the hours of 8:30am and 5:30pm (EST) weekdays, excluding holidays. TERMS Terms are Net 30 Days. Freight charges are prepaid and added to customer invoice unless
More informationAll bedside percutaneously placed tracheostomies
Page 1 of 5 Scope: All bedside percutaneously placed tracheostomies Population: All ICU personnel Outcomes: To standardize and outline the steps necessary to safely perform a percutaneous tracheostomy
More informationSubglottic stenosis, with involvement of the lower larynx
Laryngotracheal Resection and Reconstruction John D. Mitchell, MD n, Subglottic stenosis is being recognized with increasing frequency in adults, and may be the most frequent indication for airway intervention
More informationEGIS ESOPHAGEAL STENT. 1. Features & Benefits 2. Ordering information 3. References & Clinical case
EGIS ESOPHAGEAL STENT 1. & Benefits 2. Ordering information 3. References & Clinical case 1. & Benefits (1) Benefits Superior flexibility & conformability Improving compliance in curved organ(tortuous
More information8/8/2013. Disclaimer. Tracheostomy Care in the Home. Polling Question 1. Upper Airway and Respiratory System
Disclaimer Appendix 3 Declaration of Vested Interest Form Name of presenter: Heather Murgatroyd RRT RPSGT Name of employer: DeVilbiss Healthcare Tracheostomy Care in the Home Heather Murgatroyd, RRT, RPSGT
More informationShiley Tracheostomy Products Quick Reference Guide
Shiley Tracheostomy Products Quick Reference Guide SHILEY ACCESSORIES 8A DIC SIC DICFN 8B 8C 8A. Inner Cannula, Disposable (DIC) with integral 15mm snap-lock connector, individually sterile packaged, required
More informationINDEPENDENT LUNG VENTILATION
INDEPENDENT LUNG VENTILATION Giuseppe A. Marraro, MD Director Anaesthesia and Intensive Care Department Paediatric Intensive Care Unit Fatebenefratelli and Ophthalmiatric Hospital Milan, Italy gmarraro@picu.it
More informationCase Report. Management of recurrent distal tracheal stenosis using an endoprosthesis: a case report* Abstract. Introduction.
121 Case Report Management of recurrent distal tracheal stenosis using an endoprosthesis: a case report* André Germano Leite 1, Douglas Kussler 2 Abstract The authors report the case of a patient with
More informationDISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management
DISCOVER NEW HORIZONS IN FLUID DRAINAGE Bringing Safety and Convenience to Fluid Drainage Management DRAIN ASEPT Pleural and Peritoneal Drainage Catheter System 600mL or 1,000mL Evacuated Drainage Bottle
More information