Section of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou

Size: px
Start display at page:

Download "Section of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou"

Transcription

1 Section of total knee replacement Total Knee Replacement System Knieendoprothesen System Système de prothèse totale de genou Introduction: This knee system features great versality with its modular component design and an instrument system that allows the surgeon to select the operative technique which best suits him and his patient. It also affords the option of retaining or resecting the posterior cruciate ligament. The components are designed to be used in a press-fit cemented. Specific features of the system offer the following advantages; Cemented using conservative cemen techniques. Cementless based on press-fit experience. Fixation system, size and shapes adapted to the inividual anatomy of the femur, tibia and patella. Maximum congruency between femoral and tibial and between patellar and femoral component to minimize polyethylene wear. Prosthetic shapes contribute to stability throughout a full range of movement. All femoral components are comparable with all the tibial components. Minimal bone resection, consistent with pathological condition. Accuracy ensures optimal fit at prosthesis-bone interface. Option for extra or intramedullary alignment, the use of a tensor posterior cruciate retention or section. C-

2 The Stemless Femoral Components Indication : The stemless femoral components is designed to resurface the degenereted articular surfaces of the femur. The system is designed to provide four widths of prothesis for more accurate anatomical fit. This femoral component is available for primary knees without stem and used with two titanium splined pegs. : This stemless femoral component is manufactured from casting Cr.Co-alloy according to ASTM F.75 - ISO 58/. This alloy characterized by demonstrating excellent biocompatibility together with a high resistance of corrosion and superiormechanical s () L L Style Tibial Metal Back Indication : These components are designed to replace the articular surface of the degenerated tibia as part of a total needed replacement. The tibial metal back component will accept the usual maximum area contact polyethylene component or a minimally constrained component. : The tibial metal back is manufactured from titanium TiAlV according to ASTM F. - ISO 58/. which has been specifically designed for the manufacture of orthopaedic implants C-

3 Tibial Polyethylene Components Indication : Totally resurfaces the tibial plateau incorporating a metal stem for patients needing extra stability. The polyethyene insert is supported by metal to minimise potential cold flow. : UHMWPE Ultra Heavy Molecular Weight Polyethylyene meets ASTM F.8 and ISO 58/ standards. Selected for its, high degree of purity, good biotolerance, good mechanical performance and friction properties. Less Constrained Constrained K L C-

4 Tibial Stems Indication : The tibial stems are modular to allow the surgeon to select the optimal length which is usually 5, 8 or in the primary knee. : The tibial modular stem is manufactured from titanium TiAlV according to ASTM F. - ISO 58/. which has been specifically designed for the manufacture of orthopaedic implants. Patella Component Indication : The design of patella component provides increased contact area to reduce surface stress. It provides more accurate patello-femoral articulation and the two availbale sizes permit more precise conformance to anatomic requirements. : UHMWPE Ultra Heavy Molecular Weight Polyethylyene meets ASTM F.8 and ISO 58/ standards. Selected for its, high degree of purity, good biotolerance, good mechanical performance and friction properties. Polyethylene Condylar Anchorage Peg Indication : It is possible to use either polyethylene finned pegs or titanium splined pegs with the base plate and femoral component. : The condylar anchorage peg is manufactured from titanium TiAlV according to ASTM F. - ISO 58/. Certified -alloy according to ASTM F.75 - ISO 58/. Which has been specifically designed for the manufacture of orthopaedic implants. Polyethylene -alloy Diam C-

5 Modular Revision Femoral Components Indication : The modular revision femoral component provides extra stability with modular stem together and it may be used in revision surgery. Revision arthroplasty is indicated for aseptic loosening of condylar or unicompartmental prostheses. It may also be carried out either as one or two stages procedure for saptic loosening. Occasionaly the bony anatomy is such as to make the use of the revision components more appropriate than the standard implants. : This modular steed femoral component is manufactured from casting Cr.Co-alloy according to ASTM F.75 - ISO 58/. This alloy characterized by demonstrating excellent biocompatibility together with a high resistance of corrosion and superiormechanical s () L L Style Modular Revision Stem Indication : To be used in conjuction of revision femoral component for providing extra stability in revision surgery. Available in three different lengths (-- ). : The modular revision stem is manufactured from TiAlV according to ASTM F.-ISO 58/ which has been specifically designed for manufacture of orthopaedic Stem 8 C-5

6 Modular Femoral Augment Components Indication : To be used with femoral revision component. : The femoral augments components is manufactured from TiAlV alloy according to ASTM F. and ISO 58/. K () () Style Revision Condylar Anchorage Peg Indication : To be used with femoral revision component. : The femoral augments components is manufactured from TiAlV alloy according to ASTM F. and ISO 58/. Certified -alloy according to ASTM F.75 - ISO 58/. This product is in the sterile packing with Modular Femoral Augment Components alloy 555 C-

7 Tibial Metal Back Indication : These components are designed to replace the articular surface of the degenerated tibia as part of a total needed replacement. The tibial metal back component will accept the usual maximum area contact polyethylene component or a minimally constrained component. : The tibial metal back is manufactured from titanium TiAlV according to ASTM F. - ISO 58/. which has been specifically designed for the manufacture of orthopaedic implants Modular Tibial Augment Component Complete Indication : To be used with tibial component. : The tibial augments components is manufactured from TiAlV alloy according to ASTM F. and ISO 58/ K () () Revision Condylar Anchorage Peg with Support Indication : To be used with tibial component. : The tibial augments components is manufactured from TiAlV alloy according to ASTM F. and ISO 58/. Certified -alloy according to ASTM F.75 - ISO 58/ alloy 555 This product is in the sterile packing with Modular Tibial Augment Components Complete. C-7

8 Modular Tibial Half Augment Components Indication : To be used with tibial component. : The tibial augments components is manufactured from TiAlV alloy according to ASTM F. and ISO 58/. K () () Revision Condylar Anchorage Peg with Support Indication : To be used with tibial component. : The tibial augments components is manufactured from TiAlV alloy according to ASTM F. and ISO 58/.Certified -alloy according to ASTM F.75 - ISO 58/ alloy 555 This product is in the sterile packing with Modular Tibial Augment Components Complete. Condylar Anchorage Peg Indication : It is possible to use either polyethylene finned pegs or titanium splined pegs with the base plate and femoral component. : The condylar anchorage peg is manufactured from titanium TiAlV according to ASTM F. - ISO 58/. Certified -alloy according to ASTM F.75 - ISO 58/. Which has been specifically designed for the manufacture of orthopaedic implants. -alloy Diam This product is in the sterile packing with Modular Tibial Augment Components Complete. 5 C-8

9 Tibial Polyethylene Components Indication : Totally resurfaces the tibial plateau incorporating a metal stem for patients needing extra stability. The polyethyene insert is supported by metal to minimise potential cold flow. : UHMWPE Ultra Heavy Molecular Weight Polyethylyene meets ASTM F.8 and ISO 58/ standards. Selected for its, high degree of purity, good biotolerance, good mechanical performance and friction properties. Less Constrained Constrained K L C-9

10 Tibial Stems Indication : The tibial stems are modular to allow the surgeon to select the optimal length which is usually 5, 8 or in the primary knee. : The tibial modular stem is manufactured from titanium TiAlV according to ASTM F. - ISO 58/. which has been specifically designed for the manufacture of orthopaedic implants. Patella Component Indication : The design of patella component provides increased contact area to reduce surface stress. It provides more accurate patello-femoral articulation and the two availbale sizes permit more precise conformance to anatomic requirements. : UHMWPE Ultra Heavy Molecular Weight Polyethylyene meets ASTM F.8 and ISO 58/ standards. Selected for its, high degree of purity, good biotolerance, good mechanical performance and friction properties. Polyethylene Condylar Anchorage Peg Indication : It is possible to use either polyethylene finned pegs or titanium splined pegs with the base plate and femoral component. : The condylar anchorage peg is manufactured from titanium TiAlV according to ASTM F. - ISO 58/. Certified -alloy according to ASTM F.75 - ISO 58/. Which has been specifically designed for the manufacture of orthopaedic implants. Polyethylene -alloy Diam C-

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System Over 20 Years of Proven Clinical Success Zimmer Natural-Knee II System CSTi Porous Coating Structurally similar to human bone CSTi porous coating combines the excellent biocompatibility of titanium with

More information

Section of Modular Hip Prostheses cemented. TMC-3 Modular Hip Prosthesis, cemented. TMC-3 Modular Hüftprothese, zementiert

Section of Modular Hip Prostheses cemented. TMC-3 Modular Hip Prosthesis, cemented. TMC-3 Modular Hüftprothese, zementiert Section of Modular Hip Prostheses cemented TMC-3 Modular Hip Prosthesis, cemented TMC-3 Modular Hüftprothese, zementiert Prothèse de hanche modulaire TMC-3, cimentée Indication : The TMC-3 Modular hip

More information

Total Knee Replacement

Total Knee Replacement Total Knee Replacement A total knee replacement, also known as total knee arthroplasty, involves removing damaged portions of the knee, and capping the bony surfaces with man-made prosthetic implants.

More information

Knee Replacement Implants

Knee Replacement Implants Knee Replacement Implants During knee replacement surgery, an orthopaedic surgeon will resurface your damaged knee with artificial components, called implants. There are many different types of implants.

More information

Partial Knee Replacement

Partial Knee Replacement Partial Knee Replacement A partial knee replacement removes damaged cartilage from the knee and replaces it with prosthetic implants. Unlike a total knee replacement, which removes all of the cartilage,

More information

CONSENSUS ORTHOPEDICS INC. CONSENSUS KNEE SYSTEM

CONSENSUS ORTHOPEDICS INC. CONSENSUS KNEE SYSTEM CONSENSUS ORTHOPEDICS INC. CONSENSUS KNEE SYSTEM IMPORTANT INFORMATION FOR SURGEON: PLEASE READ PRIOR TO IMPLANTING THIS DEVICE IN A CLINICAL SETTING. THE SURGEON SHOULD BE FAMILIAR WITH THE SURGICAL TECHNIQUE.

More information

PARTIAL KNEE REPLACEMENT

PARTIAL KNEE REPLACEMENT PARTIAL KNEE REPLACEMENT A partial knee replacement removes damaged cartilage from the knee and replaces it with prosthetic implants. Unlike a total knee replacement, which removes all of the cartilage,

More information

Important notice: the device(s) can be prescribed and implanted only by a doctor legally authorized to perform this type of surgery.

Important notice: the device(s) can be prescribed and implanted only by a doctor legally authorized to perform this type of surgery. rev.10 CAUTION Federal law (USA) restricts this device to sale, by or on the order of a physician. ENGLISH - EVOLIS/GMK KNEE PROSTHESIS - INSTRUCTIONS FOR USE Important notice: the device(s) can be prescribed

More information

Total Knee Original System Primary Surgical Technique

Total Knee Original System Primary Surgical Technique Surgical Procedure Total Knee Original System Primary Surgical Technique Where as a total hip replacement is primarily a bony operation, a total knee replacement is primarily a soft tissue operation. Excellent

More information

Dual Articular.

Dual Articular. Dual Articular 2000 www.biomet.co.uk D e s i g n R a t i o n a l e The Dual Articular Knee has been in use since 1991 and offers a flexible reconstructive solution for total knee surgery; for both revision

More information

Biomechanical Investigations on the Total Knee Arthroplasty (TKA)

Biomechanical Investigations on the Total Knee Arthroplasty (TKA) Fernando Fonseca, MD PhD Hospitais da Universidade de Coimbra Faculdade de Medicina / Universidade de Coimbra Faculdade de Ciências da Saúde / Universidade da Beira Interior pereirafonseca@gmail.com KNEE

More information

Stefan Rahm MD University Hospital Balgrist

Stefan Rahm MD University Hospital Balgrist Knee Prosthesis Models & Materials, Surgical Techniques and Approaches Stefan Rahm MD University Hospital Balgrist INTRODUCTION VARUS VALGUS 46 Y OLD MALE Pain in the medial compartment left more than

More information

Zimmer Segmental System

Zimmer Segmental System Zimmer Segmental System Simple solutions for solving complex salvage cases A Step Forward The Zimmer Segmental System is designed to address patients with severe bone loss associated with disease, trauma

More information

TOTAL KNEE ARTHROPLASTY (TKA)

TOTAL KNEE ARTHROPLASTY (TKA) TOTAL KNEE ARTHROPLASTY (TKA) 1 Anatomy, Biomechanics, and Design 2 Femur Medial and lateral condyles Convex, asymmetric Medial larger than lateral 3 Tibia Tibial plateau Medial tibial condyle: concave

More information

CLINICAL AND OPERATIVE APPROACH FOR TOTAL KNEE REPLACEMENT DR.VINMAIE ORTHOPAEDICS PG 2 ND YEAR

CLINICAL AND OPERATIVE APPROACH FOR TOTAL KNEE REPLACEMENT DR.VINMAIE ORTHOPAEDICS PG 2 ND YEAR CLINICAL AND OPERATIVE APPROACH FOR TOTAL KNEE REPLACEMENT DR.VINMAIE ORTHOPAEDICS PG 2 ND YEAR Evolution of TKR In 1860, Verneuil proposed interposition arthroplasty, involving the insertion of soft tissue

More information

Biomechanics of. Knee Replacement. Mujda Hakime, Paul Malcolm

Biomechanics of. Knee Replacement. Mujda Hakime, Paul Malcolm Biomechanics of Knee Replacement Mujda Hakime, Paul Malcolm 1 Table of contents Knee Anatomy Movements of the Knee Knee conditions leading to knee replacement Materials Alignment and Joint Loading Knee

More information

Sulzer Orthopedics Joint & Fracture Care

Sulzer Orthopedics Joint & Fracture Care Sulzer Orthopedics Joint & Fracture Care Natural-Knee Family Anatomic design for superior clinical results. Natural-Knee Natural-Knee Family: A solution for every knee. Asymmetric design increases coverage

More information

Revision systems. Catalogue - revision implants ARTHROPLASTY

Revision systems. Catalogue - revision implants ARTHROPLASTY evision systems Catalogue revision implants ATHOPASTY Material for implants Contens ist of materials MATEIA ISO DIN ASTM Stainless steel Wrought high nitrogen stainless steel Unalloyed titanium 321 329

More information

Knee arthroplasty: What radiologists should know.

Knee arthroplasty: What radiologists should know. Knee arthroplasty: What radiologists should know. Poster No.: C-2174 Congress: ECR 2014 Type: Educational Exhibit Authors: J. Araújo 1, J. Pires 2, J. Oliveira 3, C. Macedo 1, S. Magalhães 1, I. Ferreira

More information

National Joint Replacement Registry. Outcomes of Classes No Longer Used Hip and Knee Arthroplasty SUPPLEMENTARY

National Joint Replacement Registry. Outcomes of Classes No Longer Used Hip and Knee Arthroplasty SUPPLEMENTARY National Joint Replacement Registry Outcomes of Classes No Longer Used Hip and Knee Arthroplasty SUPPLEMENTARY Report 2017 AOAnjrr 2016 supplementary report AOAnjrr 2016 supplementary report Contents SUMMARY...

More information

Hip Implants. Hip Implants. 6 Your partner for implants and trauma products. Euromed Implants GmbH General Catalogue

Hip Implants. Hip Implants. 6 Your partner for implants and trauma products. Euromed Implants GmbH General Catalogue 6 Modular Straight Cemented Stem The modular straight cemented stem hip prosthesis is designed to be used as a primary and revision total hip. The 4 stem sizes allow accurate matching of prosthesis to

More information

Operations included in the National Joint Registry (NJR)

Operations included in the National Joint Registry (NJR) Operations included in the National Joint Registry (NJR) Quick links, go to: Hips > Knees > Ankles > Elbows > Shoulders > Trauma > Version 8 June 2018 1 Version control Version number Date Amendments 1

More information

Vanguard Complete Knee System

Vanguard Complete Knee System Complete Knee System Design Rationale Knees Hips Extremities Cement and Accessories PMI Technology 1 One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized

More information

JOINT RULER. Surgical Technique For Knee Joint JRReplacement

JOINT RULER. Surgical Technique For Knee Joint JRReplacement JR JOINT RULER Surgical Technique For Knee Joint JRReplacement INTRODUCTION The Joint Ruler * is designed to help reduce the incidence of flexion, extension, and patellofemoral joint problems by allowing

More information

Consistency in U2 Knee System over Time

Consistency in U2 Knee System over Time U2 TM Knee System Consistency in U2 Knee System over Time Share the same femoral profile of all types allow inter-changibility Uniform AP/ML dimensions in all tibial components enhance intraoperative flexibility

More information

Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing

Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing Journal of Orthopaedic Surgery 2001, 9(1): 45 50 Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing KY Chiu, TP Ng, WM Tang and P Lam Department of Orthopaedic Surgery, The University

More information

Revolution. Unicompartmental Knee System

Revolution. Unicompartmental Knee System Revolution Unicompartmental Knee System While Total Knee Arthroplasty (TKA) is one of the most predictable procedures in orthopedic surgery, many patients undergoing TKA are in fact excellent candidates

More information

HOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX

HOSPITAL A (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX HOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX HIP IMPLANTS TOTAL HIPS Ultra High Demand (metal on metal) Femur, ingrowth Femoral head, metal Acetabular shell, ingrowth Acetabular liner,

More information

Operations included in the National Joint Registry (NJR) Quick links, go to: Hips > Knees > Ankles > Elbows > Shoulders > Trauma >

Operations included in the National Joint Registry (NJR) Quick links, go to: Hips > Knees > Ankles > Elbows > Shoulders > Trauma > Operations included in the National Joint Registry (NJR) Quick links, go to: Hips > Knees > Ankles > Elbows > Shoulders > Trauma > Version 5 December 2013 1 Version control Version number Date Amendments

More information

Pre-Op Planning for your knee replacement surgery

Pre-Op Planning for your knee replacement surgery Pre-Op Planning for your knee replacement surgery Are You Considering Knee Replacement Surgery? Knee pain can be the result of injury, biomechanical problems, or disease. When stiffness and pain in your

More information

EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE.

EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE. EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE. The year 2010 marked Exactech s silver aiversary and 25 years of mobility. As a company founded by an orthopaedic surgeon and a biomedical

More information

Regenerex Primary Tibial Tray

Regenerex Primary Tibial Tray Cruciate Retaining and Posterior Stabilized Surgical Technique Addendum to the Vanguard Complete Knee System Knees Hips Extremities Cement and Accessories PMI Technology Contents Microplasty Knee Instrumentation

More information

BULLETIN. Medial Rotation Knee Technical Dossier. Derek R Cooper Director of Sales & Marketing. 14th January 2004

BULLETIN. Medial Rotation Knee Technical Dossier. Derek R Cooper Director of Sales & Marketing. 14th January 2004 14th January 2004 Medial Rotation Knee Technical Dossier BULLETIN Bulletin No. 011 The attached document is now readily available to support your sales and marketing activities. The dossier plots the development

More information

National Joint Replacement Registry. Lay Summary 2015 Annual Report Hip and Knee Replacement

National Joint Replacement Registry. Lay Summary 2015 Annual Report Hip and Knee Replacement National Joint Replacement Registry Lay Summary 2015 Annual Report Hip and Knee Replacement SUPPLEMENTARY REPORT 2015 TABLE OF CONTENTS Introduction... 1 A brief history of the Registry origins... 1 The

More information

Intramedullary Tibial Preparation

Intramedullary Tibial Preparation Surgical Technique Intramedullary Tibial Preparation Primary Total Knee Arthroplasty LEGION Total Knee System Intramedullary tibial preparation Contents Introduction...2 IM tibial highlights...3 Preoperative

More information

Medial Rotation Knee. Technical Dossier

Medial Rotation Knee. Technical Dossier Medial Rotation Knee Technical Dossier Manufactured by MatOrtho Limited 13 Mole Business Park Randalls Road Leatherhead Surrey KT22 7BA United Kingdom. T: +44 (0)1372 224200 info@matortho.com For more

More information

CONTRIBUTING SURGEON. Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD

CONTRIBUTING SURGEON. Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD CONTRIBUTING SURGEON Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD System Overview The EPIK Uni is designed to ease the use of the

More information

Individual oncological implants

Individual oncological implants Individual oncological implants Catalogue - individual oncological implants ONCOLOGICAL Materials for implants List of materials MATERIAL ISO ČSN DIN ASTM Stainless steel 5832-1 17350 výběr 17 443 W.Nr.

More information

Product Information & Procedure Wall Chart

Product Information & Procedure Wall Chart Partial Knee System Product Information & Procedure Wall Chart Reproducible, balanced approach to partial knee replacement Developed by Dr. Gerard A. Engh Dr. Engh is renowned for his expertise in developing

More information

Revision Surgical Technique

Revision Surgical Technique TOTAL KNEE SYSTEM Revision Surgical Technique GENESIS II Revision Surgical Technique TABLE OF CONTENTS Introduction................................... 2 Preop Planning.................................

More information

OSS Overview Biomet Oncology Salvage System Featuring the Finn Knee

OSS Overview Biomet Oncology Salvage System Featuring the Finn Knee OSS Overview Biomet Oncology Salvage System Featuring the Finn Knee Biomet, Finn & Arcom are trademarks of Biomet Inc. 1 Table of Contents Overview...page 4 Introduction History of Hinged Knees Clinical

More information

Proven Gen-Flex Revision Knee System. Surgical Protocol

Proven Gen-Flex Revision Knee System. Surgical Protocol Proven Gen-Flex Revision Knee System Surgical Protocol Proven Gen-Flex Revision Knee System Surgeon Design Team The Proven Gen-Flex Revision Knee System Instrumentation and Surgical Protocol were developed

More information

Zimmer NexGen Rotating Hinge Knee Primary/ Revision

Zimmer NexGen Rotating Hinge Knee Primary/ Revision Zimmer NexGen Rotating Hinge Knee Primary/ Revision Surgical Technique Designed for use in revision and difficult primary surgeries 1 INTRODUCTION The NexGen Rotating Hinge Knee Components are designed

More information

Saiph Knee System. Technical Dossier

Saiph Knee System. Technical Dossier Saiph Knee System Technical Dossier Developed in collaboration with an international surgical team Professor Justin P Cobb Chair in Orthopaedic Surgery Imperial College Hospital, London Professor Fares

More information

Why precision is powerful

Why precision is powerful Why precision is powerful A new answer for isolated patellofemoral OA First generation PFJ implants had sharp, constraining trochlear grooves and were prone to complications such as maltracking and catching

More information

Surgical Technique. Poly UHMWPE. Bio Hyaluronic Acid. Advancing Materials. Advancing Outcomes.

Surgical Technique. Poly UHMWPE. Bio Hyaluronic Acid. Advancing Materials. Advancing Outcomes. Surgical Technique Bio Hyaluronic Acid Poly UHMWPE Advancing Materials. Advancing Outcomes. Surgical 2 Assessment 1. Proper implant sizing is determined by placing the appropriate sized trial over the

More information

Aesculap Orthopaedics univation

Aesculap Orthopaedics univation Aesculap Orthopaedics univation Knee Endoprosthesis System one system two knees Secure alignment and implantation with OrthoPilot UNIVATION one system two knees The univation System provides implant precision,

More information

Instrumentation Options

Instrumentation Options Instrumentation Options With the introduction of Microplasty and Premier Instrumentation platforms and advancements such as our patented Slidex Technology, the Vanguard Complete Knee System is the surgeon

More information

Integra Cadence Total Ankle System PATIENT INFORMATION

Integra Cadence Total Ankle System PATIENT INFORMATION Integra Cadence Total Ankle System PATIENT INFORMATION Fibula Articular Surface Lateral Malleolus Tibia Medial Malleolus Talus Anterior view of the right ankle region Talo-fibular Ligament Calcaneal Fibular

More information

PARTIALS?1 SHOULD BE AT LEAST 20% DID YOU KNOW OF KNEE REPLACEMENTS

PARTIALS?1 SHOULD BE AT LEAST 20% DID YOU KNOW OF KNEE REPLACEMENTS PARTIAL KNEE DID YOU KNOW AT LEAST 20% OF KNEE REPLACEMENTS SHOULD BE PARTIALS?1 Research shows that surgeons utilizing Partial Knee Arthroplasty (PKA) for at least 20% of their annual knee arthroplasties

More information

Finite Element Analysis of a Novel High Flexion Knee (Ti UHMWPE) used in Total Knee Arthroplasty

Finite Element Analysis of a Novel High Flexion Knee (Ti UHMWPE) used in Total Knee Arthroplasty ISPUB.COM The Internet Journal of Bioengineering Volume 4 Number 1 Finite Element Analysis of a Novel High Flexion Knee (Ti UHMWPE) used in Total Knee Arthroplasty S Sivarasu, M Lazar Citation S Sivarasu,

More information

The power of simplicity

The power of simplicity The power of simplicity The power of simplicity Consider the facts, and take a look at the future: Revision TKA procedures are projected to double between now and 2015. 1 Restoration of a normal joint

More information

Extramedullary Tibial Preparation

Extramedullary Tibial Preparation Surgical Technique Extramedullary Tibial Preparation Primary Total Knee Arthroplasty LEGION Total Knee System Extramedullary tibial preparation Contents Introduction...2 EM tibial highlights...3 Preoperative

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 EMPIRICAL TESTING CORP. 4628 Northpark Drive Colorado Springs, CO 80918 Dawn Lissy Phone: 719 264 9937 dlissy@empiricaltesting.com MECHANICAL Valid To: January

More information

Description Materials Indications Patient selection factors to be considered include: Contraindications Absolute contraindications include:

Description Materials Indications Patient selection factors to be considered include:  Contraindications Absolute contraindications include: Description The Patello-Femoral Wave Arthroplasty Systems incorporate a distal femoral trochlear surface articular component that mates to a taper post via a taper interlock, and an all-polyethylene patella

More information

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology Regenerex Porous Titanium Construct Knees Hips Extremities Cement and Accessories PMI Trauma Technology One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized

More information

Vanguard 360 Revision Knee System. Design Rationale

Vanguard 360 Revision Knee System. Design Rationale Vanguard 360 Revision Knee System Design Rationale One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art of medical

More information

LPS SYSTEM POCKET GUIDE

LPS SYSTEM POCKET GUIDE LPS SYSTEM POCKET GUIDE Implants Procedural Uses Instruments & Trials L P S Limb Preservation System L P S Limb Preservation System The purpose of this document is to review the LPS (Limb Preservation

More information

Surgical procedure. METS SMILES Total Knee Replacement

Surgical procedure. METS SMILES Total Knee Replacement Surgical procedure METS SMILES Total Knee Replacement Surgical Procedure Contents 1.0 2.0 3.0 4.0 Device information 2 3 1.1 Product overview 1.2 Indications 1.3 Absolute contra-indications 1.4 Relative

More information

Complications of Total Knee Arthroplasty

Complications of Total Knee Arthroplasty Progress in Clinical Medicine Complications of Total Knee Arthroplasty JMAJ 44(5): 235 240, 2001 Shinichi YOSHIYA*, Masahiro KUROSAKA** and Ryosuke KURODA*** *Director, Department of Orthopaedic Surgery,

More information

Analysis of an Early Intervention Tibial Component for Medial Osteoarthritis

Analysis of an Early Intervention Tibial Component for Medial Osteoarthritis Analysis of an Early Intervention Tibial Component for Medial Osteoarthritis Miriam Chaudhary, M.Sc. 1, Peter S. Walker, PhD 2. 1 NYU Hospital for Joint Diseases, New York City, NY, USA, 2 NYU-Hospital

More information

2016 CELEBRATING 15 YEARS OF DATA REPORT NATIONAL JOINT REPLACEMENT REGISTRY. Outcomes of Classes No Longer Used Hip and Knee Arthroplasty

2016 CELEBRATING 15 YEARS OF DATA REPORT NATIONAL JOINT REPLACEMENT REGISTRY. Outcomes of Classes No Longer Used Hip and Knee Arthroplasty NATIONAL JOINT REPLACEMENT REGISTRY Outcomes of Classes No Longer Used Hip and Knee Arthroplasty SUPPLEMENTARY REPORT 2016 CELEBRATING 15 YEARS OF DATA Contents INTRODUCTION...3 HIP REPLACEMENT...4 Partial

More information

Evolution. Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee. Key Aspects

Evolution. Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee. Key Aspects Evolution Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee Key Aspects MicroPort s EVOLUTION Medial-Pivot Knee System was designed to recreate the natural anatomy that is lost during a total

More information

YOUR TOTAL KNEE REPLACEMENT

YOUR TOTAL KNEE REPLACEMENT YOUR TOTAL KNEE REPLACEMENT Dr. M.S. Barrow Barrow Physiotherapy MBBch (Wits), FCS (SA) Orth. Waterfall City Hospital Orthopaedic Surgeon Tel: 011 304 7829 Suite 5, East Wing, Sunninghill Hospital www.barrowphysiotherapy.co.za

More information

BIOTECH FUTURE KNEE Minimal Invasive (and classic) Surgical Technique

BIOTECH FUTURE KNEE Minimal Invasive (and classic) Surgical Technique BIOTECH FUTURE KNEE Minimal Invasive (and classic) Surgical Technique Page No. Product description 2. Pre-operational planning 3. 1st step Femoral resection 4. P/S Femoral component 7. 2nd step Proximal

More information

Stephen R Smith Northeast Nebraska Orthopaedics PC. Ligament Preserving Techniques in Total Knee Arthroplasty

Stephen R Smith Northeast Nebraska Orthopaedics PC. Ligament Preserving Techniques in Total Knee Arthroplasty Stephen R Smith Northeast Nebraska Orthopaedics PC Ligament Preserving Techniques in Total Knee Arthroplasty 10-15% have Fair to poor Results? Why? The complication rate is 2.567% If It happens To You

More information

Abramsohn Retractor 1

Abramsohn Retractor 1 Abramsohn Retractor 1 Calibrated Femoral Tibial Spreaders Small Medium Large Designed to remain in position, with the femur and tibia separated, without the need of an assistant, and to minimize crushing

More information

ZIMMER NEXGEN CRUCIATE RETAINING (CR) AND LEGACY KNEE POSTERIOR STABILIZED (LPS) TRABECULAR METAL MONOBLOCK TIBIAS. Surgical Technique Addendum

ZIMMER NEXGEN CRUCIATE RETAINING (CR) AND LEGACY KNEE POSTERIOR STABILIZED (LPS) TRABECULAR METAL MONOBLOCK TIBIAS. Surgical Technique Addendum ZIMMER NEXGEN CRUCIATE RETAINING (CR) AND LEGACY KNEE POSTERIOR STABILIZED (LPS) TRABECULAR METAL MONOBLOCK TIBIAS Surgical Technique Addendum SURGICAL TECHNIQUE FOR NEXGEN CRUCIATE RETAINING (CR) AND

More information

Condylar constrained system in primary total knee replacement: our experience and literature review

Condylar constrained system in primary total knee replacement: our experience and literature review Original Article Page 1 of 5 Condylar constrained system in primary total knee replacement: our experience and literature review Luigi Sabatini 1, Salvatore Risitano 1, Lorenzo Rissolio 1, Andrea Bonani

More information

INSTRUMENTS. Product Rationale

INSTRUMENTS. Product Rationale INSTRUMENTS Product Rationale R E C O V E R Y F U N C T I O N S U R V I V O R S H I P DePuy believes in an approach to knee arthroplasty that places equal importance on recovery, function and survivorship.

More information

TOTAL KNEE SYSTEM WHEN INNOVATION AND INTUITION ALIGN.

TOTAL KNEE SYSTEM WHEN INNOVATION AND INTUITION ALIGN. TOTAL KNEE SYSTEM WHEN INNOVATION AND INTUITION ALIGN. Exactech has made history with our highly evolved Optetrak comprehensive knee system a system that has three decades of clinical success and proven

More information

Surgical Technique. VISIONAIRE FastPak Instruments for the LEGION Total Knee System

Surgical Technique. VISIONAIRE FastPak Instruments for the LEGION Total Knee System Surgical Technique VISIONAIRE FastPak Instruments for the LEGION Total Knee System VISIONAIRE FastPak for LEGION Instrument Technique* Nota Bene The technique description herein is made available to the

More information

Optimum implant geometry

Optimum implant geometry Design Rationale Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available

More information

Cementless Oxford unicompartmental knee replacement shows reduced radiolucency at one year

Cementless Oxford unicompartmental knee replacement shows reduced radiolucency at one year Cementless Oxford unicompartmental knee replacement shows reduced radiolucency at one year H. Pandit, C. Jenkins, D. J. Beard, J. Gallagher, A. J. Price, C. A. F. Dodd, J. W. Goodfellow, D. W. Murray From

More information

[ICESTM-2018] ISSN Impact Factor

[ICESTM-2018] ISSN Impact Factor GLOBAL JOURNAL OF ENGINEERING SCIENCE AND RESEARCHES MODELING AND FINITE ELEMENT ANALYSIS OF KNEE JOINT PROSTHESIS U.D.S.Prathap varma *1,S.Rajesh 2, B.Suresh Kumar 3 & P.Rama Murthy Raju 4 *1 M.TechScholar,

More information

NexGen Legacy LPS-Flex Knee. Brochure

NexGen Legacy LPS-Flex Knee. Brochure NexGen Legacy LPS-Flex Knee Brochure What postoperative range of motion can your TKA patients expect? For patients with the ability and desire to perform For patients with the ability high-flexion activities,

More information

UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD

UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS 66th Annual Meeting February 4-9, 1999 Anaheim, California COMMITTEE ON BIOMEDICAL ENGINEERING COMMITTEE ON

More information

OSSIS is an ISO accredited company.

OSSIS is an ISO accredited company. CUSTOM IMPLANTS Over the last 15 years Ossis orthopaedic surgeons and materials and design engineers have been at the leading-edge of innovation in patient-specific implants. Ossis combines the use of

More information

TRK REVISION KNEE Surgical Technique

TRK REVISION KNEE Surgical Technique 1 TRK REVISION KNEE Surgical Technique 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. INTERCONDYLAR RESECTION...... page FEMORAL STEM...... page NON CEMENTED FEMORAL STEM...... page TRIAL FEMORAL COMPONENTS...... page

More information

Endo-Model SL. Rotational and Hinge Knee Prosthesis System. Implants & Instruments

Endo-Model SL. Rotational and Hinge Knee Prosthesis System. Implants & Instruments Endo-Model SL Rotational and Hinge Knee Prosthesis System Implants & Instruments Presented by: Waldemar Link GmbH & Co. KG Barkhausenweg 10 22339 Hamburg, Germany Tel.: +49 40 53995-0 info@linkhh.de www.linkorthopaedics.com

More information

OSSIS is an ISO accredited company.

OSSIS is an ISO accredited company. CUSTOM IMPLANTS Over the last 15 years Ossis orthopaedic surgeons and materials and design engineers have been at the leading-edge of innovation in patient-specific implants. Ossis combines the use of

More information

Inspiring people, Enriching lives

Inspiring people, Enriching lives TM Inspiring people, Enriching lives Encore Medical, L.P. 9800 Metric Blvd. Austin, Texas 78758 512-832-9500 www.encoremed.com Encore Medical, L.P. Cat. # 0152-017 2.5k/rev. A Encore and Foundation are

More information

Featuring. Technology. Product Rationale

Featuring. Technology. Product Rationale Featuring Technology Product Rationale 2 Optimum implant geometry Extending proven TRI-LOCK heritage The original TRI-LOCK Stem was introduced in 1981. This implant was the first proximally coated tapered-wedge

More information

Uniglide. Unicompartmental Knee Replacement Mk III surgical technique

Uniglide. Unicompartmental Knee Replacement Mk III surgical technique Uniglide Unicompartmental Knee Replacement Mk III surgical technique Uniglide Contents Operative summary 4 Pre-operative assessment 6 Preparation 7 Incision 7 Approach 7 Medial procedure 8 Tibial preparation

More information

Product Portfolio. Consensus Knee Systems. Consensus Hip Systems

Product Portfolio. Consensus Knee Systems. Consensus Hip Systems 1115 Windfield Way, Suite 100 El Dorado Hills, Ca 95762 916-355-7100, 916-355-7190 info@consensusortho.com consensusortho.com Product Portfolio Consensus Knee Systems Consensus Hip Systems Product Portfolio

More information

KRI M-O-M knee reconstruction implant surgical technique Femorotibial M-O-M coupling

KRI M-O-M knee reconstruction implant surgical technique Femorotibial M-O-M coupling knee reconstruction implant surgical technique Femorotibial M-O-M coupling knee reconstruction implant surgical technique Femorotibial M-O-M coupling MUTARS was developed in co-operation with Prof. Dr.

More information

ANATOMIC SURGICAL TECHNIQUE. 5 in 1. Conventional instrumentation 07/11/2013

ANATOMIC SURGICAL TECHNIQUE. 5 in 1. Conventional instrumentation 07/11/2013 ANATOMIC SURGICAL TECHNIQUE 5 in 1 Conventional instrumentation PRO.GB.933/1.0 Octobre 2013 2 Tibial step 3 Intramedullary technique - Based on the preoperative plan, drill the medullary canal with the

More information

Rationale and Surgical Technique

Rationale and Surgical Technique Rationale and Surgical Technique Trekking Primary Knee Integrated System Rationale The implant system Trekking is one of the most advanced systems for total knee arthroplasty available today. All the principal

More information

I want that next-generation knee

I want that next-generation knee I want that next-generation knee High flex Potentially longer-lasting More normal feeling Gender-optimized Less-invasive procedure Advanced design technology The last ten years have yielded an explosion

More information

Triathlon Tritanium Knee System

Triathlon Tritanium Knee System Triathlon Tritanium Knee System Table of Contents Cementless TKA... 4 Why Cementless TKA?... 4 Cementless TKA - Clinical History... 4 Published RSA Results Comparing Fixation Methods... 5 Biologic Fixation...

More information

Knee Revision. Portfolio

Knee Revision. Portfolio Knee Revision Portfolio I use the DePuy Revision Knee System because of its versatility. With this system I can solve nearly any situation I encounter in the OR. Dr. Thomas Fehring, OrthoCarolina Hip and

More information

A Systematic Review on Performance of the Vanguard Complete Knee System

A Systematic Review on Performance of the Vanguard Complete Knee System A Systematic Review on Performance of the Vanguard Complete Knee System Author: Jing Xie, Ph.D. June 30, 2011 Abstract A systematic review was conducted to evaluate the clinical performance of the Vanguard

More information

Arcos Modular Femoral Revision System

Arcos Modular Femoral Revision System Arcos Modular Femoral Revision System Arcos System Simplify the Complex The Arcos Modular Femoral Revision System meets the demands of complex hip revision surgery by offering surgeons and OR staff the

More information

Surgical Technique Final Trial Reduction and Component Implantation of

Surgical Technique Final Trial Reduction and Component Implantation of Surgical Technique Final Trial Reduction and Component Implantation of TC *smith&nephew TC-PLUS PRIMARY Mobile Bearing TC-PLUS PRIMARY Mobile Bearing Final Trial Reduction and Component Implantation of

More information

RS Arthrodesis Implant surgical technique

RS Arthrodesis Implant surgical technique RS Arthrodesis Implant surgical technique RS Arthrodesis implant surgical technique MUTARS was developed in co-operation with Prof. Dr. W. Winkelmann (former director) and Prof. Dr. G. Gosheger (director),

More information

Hard Implants. Lecture #13

Hard Implants. Lecture #13 Hard Implants Lecture #13 Refs: 1. Park, J. B. and Bronzino, J. D., eds., Biomaterials: Principles and Applications. CRC Press, Boca Raton, FL, 2003. 2. Park, J. B., Biomaterials Science and Engineering.

More information

Both Knee Re-revision Operations with Different Types of Endoprosthesis after Septic Complications

Both Knee Re-revision Operations with Different Types of Endoprosthesis after Septic Complications DOI: 10.2478/v10163-012-0036-2 ACTA CHIRURGICA LATVIENSIS 2011 (11) CASE REPORT Both Knee Re-revision Operations with Different Types of Endoprosthesis after Septic Complications Silvestris Zebolds*/***,

More information

Torn ACL - Anatomic Footprint ACL Reconstruction

Torn ACL - Anatomic Footprint ACL Reconstruction Torn ACL - Anatomic Footprint ACL Reconstruction The anterior cruciate ligament (ACL) is one of four ligaments that are crucial to the stability of your knee. It is a strong fibrous tissue that connects

More information

U2 PSA. Revision Knee. Surgical Protocol

U2 PSA. Revision Knee. Surgical Protocol U2 PSA TM Revision Knee Surgical Protocol Table of Contents 1 Component Removal... 2 Tibial Preparation... 2.1 Tibial Canal Preparation... 2.2 Proximal Tibial Resection... 2.3 Non Offset Tibial Preparation...

More information

Uniglide. Unicompartmental Knee Replacement Mk III surgical technique. The mobile bearing is not commercially available in the USA

Uniglide. Unicompartmental Knee Replacement Mk III surgical technique. The mobile bearing is not commercially available in the USA Uniglide Unicompartmental Knee Replacement Mk III surgical technique The mobile bearing is not commercially available in the USA Uniglide Contents Introduction 4 Compatibility chart 7 Operative summary

More information