Syringes & Liquid Handling

Size: px
Start display at page:

Download "Syringes & Liquid Handling"

Transcription

1 Syringes & Liquid Handling Hamilton Manual Syringes Manual Syringe Guide Microliter Syringes Gastight Syringes Syringe Accessories Syringe Cleaning & Maintenance Hamilton LC Autosampler Syringes CTC LC Autosampler Syringes Syringes for Manual HPLC Valves Syringes for Valco VISF-1 Valves Hamilton GC Autosampler Syringes Syringes for Agilent Syringes for Thermo Scientific Syringes for Shimadzu CTC GC Autosampler Syringes Hamilton Pipettes SoftGrip Single Channel Pipettes SoftGrip Multi-Channel Pipettes Pipette Tips SofTop Quick Dispenser Hamilton Microlab 600 MicroLab Dual Syringe Diluters MicroLab Dispensers Microlab Software Replacement Parts Valves, Tubing, Upgrade Kits & Accessories Hand Probes, Foot Switch & Printer Kit Standalone Syringe Pumps

2 Featured Products 408 Hamilton Syringes 416 Hamilton Syringe Accessories Reproducibility (Chaney) Adapter Improve the reproducibility of multiple manual injections with the Chaney Adapter. Calibrated Syringe A Certificate of Calibration is provided with the product and the procedure is performed with an unbroken chain of calibrations traceable to N.I.S.T. procedure Digital Syringe 4 Hamilton SoftGrip Pipettes 46 Hamilton MicroLab 600 Diluters & Dispensers Reduce time preparing samples or dispensing reagents Minimize experimental variation from one user to the next Manage log files from any PC Comply with EPA, FDA GLP and GMP, 1 CFR Part 11, and ISO N.I.S.T. traceable calibration Notes from the Support Desk Hamilton Syringe FAQ What is the accuracy of Hamilton syringes? Hamilton syringes are manufactured to be accurate within ±1% of nominal volume, and with precision within 1%, measured at 80% of total scale volume. The design of our barrel and plunger dimensions assures high levels of accuracy and precision. The Hamilton Company Quality System is ISO certified. Can Hamilton syringes be used on humans? Hamilton syringes are not manufactured for human use. To discuss potential off label uses for Hamilton syringes please contact us. Is the volume of fluid in the needle part of the total volume of the dispensed fluid? When using a Hamilton syringe, the volume in the needle (called dead volume) is considered constant and the volume being dispensed is absolute. The same dead volume is maintained throughout aspirate and dispense stages. What are the most versatile syringes made by Hamilton? Gastight syringes are the most versatile syringes. Plungers are replaceable if they get bent. Any of the Metal hub, Kel-F or Removable needle allow for the replacement of needle if they become bent or plugged. How can I sterilize my syringe? Chemical sterilization is the preferred method for all Hamilton products. Autoclaving syringes should only be used as a last resort and only where specifically stated. Syringe sterilization is not straightforward. Not all syringes can be autoclaved. Is the Digital Syringe automated or manual? The Digital Syringe is a manual syringe with a digital display which allows you to clearly see the aspirated volume. The Digital Syringe is not automated, it will not dispense with the touch of a button. It operates like a typical syringe, but there is no guessing as to the volume being aspirated or dispensed. What does the "s" mean in a s or 6s gauge needle? The "s" represents a smaller ID for the needle and a thicker needle wall for better durability. For example, a 6 gauge needle has an OD of 0.46 mm and an ID of 0.6 mm while the 6s gauge needle has an OD of 0.47 mm and an ID of 0.1 mm. The 6s has half the ID of the 6 gauge needle. The difference in the wall thickness also nearly doubled with 6s gauge having a thickness of 0.18 mm while the 6 gauge is only 0.10 mm. "s" indicates a added strength. O.D. 0.7 mm I.D mm O.D. 0.7 mm s I.D mm Syringes & Liquid Handling

3 SYRINGES Hamilton Manual Syringes Hamilton Manual Syringes Standard Needle Point Styles POINT STYLE DESCRIPTION APPLICATION 10 1 sharp, beveled, curved non-coloring Gas chromatography, septum piercing Syringe Terminations TERMINATION REMARK AUTOCLAVABLE Cemented Needle (N) For low-volume syringes No Blunt, electro-polished HPLC injection, thin-layer chromatography (TLC), general liquid handling Luer Tip Cemented Needle (LTN) For mid-volume syringes No Conical with side port for penetration without coring Headspace, applications prone to needle clogging, minimal septum damage Removable Needle (RN) Yes if disassembled AS Conical, non coring designed to withstand multiple injections Autosampler injection, pre-pierced septa Knurled Hub (KH) For Modified Microliter syringes only Yes if disassembled Needle Gauge "s" indicates a added strength. Luer Tip (LT) PTFE Luer Lock (TLL) Yes if disassembled Yes if disassembled O.D. 0.7 mm I.D mm O.D. 0.7 mm s I.D mm SampleLock (SL) Integrated on/off valve No GAUGE O.D. (mm) I.D. (mm) s Fixed Needle (FN) Found on CTC C-Line and X-Type syringes No ChemSeal (C) 1/4" 8 UNF/ threaded connection Yes if disassembled s Hamilton Syringe Series Guide The key to selecting the right syringe for your application is to identify your sample type and determine the smallest volume to be dispensed or injected. Hamilton offers two type of syringes, Gastight and Microliter, which differ in the design of the plunger. SYRINGE SERIES VOLUME SYRINGE TYPE PLUNGER TYPE PAGE NO µl µl Modified Microliter Tungsten µl µl Microliter Reinforced stainless steel fitted µl 00 µl Microliter Stainless steel fitted µl 0 µl Microliter Reinforced stainless steel fitted µl 10 µl Microliter Reinforced stainless steel fitted µl 00 µl Gastight PTFE tipped ml 100 ml Gastight PTFE tipped µl 0 µl Gastight Reinforced PTFE tipped 414 Super Syringe 0. L L Gastight Acrylic plunger with Buna-N O-ring Chrom Tech your chromatography specialists

4 Hamilton Manual Syringes SYRINGES Hamilton Modified Microliter Syringes 7000 Series These syringes are designed to dispense volumes below μl. This requires an extremely small tungsten plunger wire that travels to the tip of the needle. The resulting design has zero dead volume and is accurate below 0 nl. The 7000 series syringe is used for dispensing minute liquid volumes and features a Modified Microliter design. The series employs a plunger wire inside the needle to accurately dispense ultra-low volumes. The needle is bored to extremely accurate tolerances to accommodate the plunger wire. With the plunger inside the needle, the standard dead volume inside the needle is eliminated. Tightening the nut applies force to the ferrule The black sleeve indicates volume and protects the plunger wire Plunger travels inside the needle through to the tip The PTFE ferrule presses into the Knurled Hub to create a seal around the plunger wire HAMILTON 7000 SERIES Knurled Hub VOLUME 0. µ L 0. µ L 1 µ L 1 µ L µ L µ L µ L MODEL GAUGE 4 Knurled Hub (KH) Syringe (point style ) Knurled Hub (KH) Syringe (point style ) N/A ACCESSORIES (Syringe not included) Reproducibility Adapter Syringe Guide Digital Syringe For Syringe Calibration Service, add the prefix "CAL" to the beginning of the syringe s part number. Note: Needles are 70 mm; Max temperature: 9 F (11 C); Max pressure: 6,000 PSI 1) Needle length is 100 mm Add the prefix "DS" to the beginning of the syringe s part number. (Base unit not sold separately) Hamilton Microliter Syringes 600 Series The 600 series are robust syringes consisting of two distinct parts. The bottom half of the barrel accurately measures the liquid sample and the top half supports the plunger. In addition, the top section of the plunger is thicker to further reduce the risk of bending the plunger. These syringes require half of the standard stroke length making them ideal for one-handed operation. The plungers and barrels are not interchangeable or replaceable. HAMILTON 600 SERIES Removable Needle Syringes & Repl Needles s "s" indicates added strength VOLUME. µ L µ L MODEL 6 6 GAUGE s s (point style ) For Syringe Calibration Service, add the prefix "CAL" to the beginning of the syringe s part number. Note: Needles are 1 mm; Max temperature: 9 F (11 C); Max pressure:,000 PSI Point Style Small RN Small RN Recommended Use: The 600 series is great for animal injections because one hand is free for manipulating the animal. Authorized Distributor

5 SYRINGES Hamilton Manual Syringes Hamilton Microliter Syringes 700 Series HAMILTON 700 SERIES Cemented Needle Syringes Removable Needle Syringes & Repl Needles Luer Tip Syringes & Repl Needles s "s" indicates added strength VOLUME µl 10 µl µl 0 µl 100 µl 0 µl 00 µl MODEL GAUGE 6s 6s s s s s LENGTH mm mm mm mm mm mm mm Cemented Needle (N) Syringe (point style ) Cemented Needle (N) Syringe (point style ) Cemented Needle (N) Syringe (specify needle) (point style ) Replacement RN Needles Luer Tip (LT) Syringe Replacement Hub Needles (6/pk) (6/pk) Point Style Small RN Small RN Small RN Small RN Small RN Large RN Large RN N/A Point Style Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub ACCESSORIES (Syringe not included) PB600 Repeating Dispenser N/A N/A Reproducibility (Chaney) Adapter Syringe Guide Digital Base Unit Add the prefix "DS" to the beginning of the syringe s part number. (Base unit not sold separately) 1) gauge ) s gauge For Syringe Calibration Service, add the prefix "CAL" to the beginning of the syringe s part number. Note: Max temperature: Cemented Needle: 1 F (0 C), All others: 9 F (11 C) Max pressure: 100 µl:,000 PSI, All others: 1,000 PSI Digital Syringe Reproducibility (Chaney) Adapter Syringe Guide Microliter Syringes 600, 700, 800 and 900 Series Microliter syringes are for use with liquids and incorporates a stainless steel plunger that is individually fitted to it s matching syringe barrel (they are not interchangeable be very careful to keep each plunger with its original syringe). These micro-volume syringes have a very close tolerance between the plunger and the barrel which creates a liquid-tight seal without parts such as O-rings that eventually wear out. These syringes are ideal for aqueous and organics samples that are not prone to precipitation, crystallization or bonding with glass. Point style gauge Termination Flange Needle gauge Barrel with graduations Fitted plunger 410 Chrom Tech your chromatography specialists

6 Hamilton Manual Syringes SYRINGES Hamilton Microliter Syringes 800 Series The 800 series syringes are a reinforced plunger version of the 700 series. The 800 series has the same liquid handling capabilities as the 700 series, but with the addition of a blue removable aluminum syringe holder that attaches to the flange of the syringe. The syringe holder prevents heat transfer, dispense inaccuracies, plunger blow outs and plunger bending during injection. A two-piece extended plunger further eliminates the risk of breakage. A friction screw at the top of the barrel can be adjusted to give the user some control over dispensing speed and prevent the accidental removal of the plunger. In addition, the syringe holder can be fitted with different barrel/plunger assemblies to cover a range of volumes. Recommended Use: This syringe is intended for applications where the plunger on a 700 series syringe might be bent. Excellent for novice users. HAMILTON 800 SERIES Removable Needle Syringes & Repl Needles s "s" indicates added strength VOLUME µ L 10 µ L µ L 0 µ L 100 µ L 0 µ L MODEL GAUGE 6s 6s s s s s Cemented Needle (N) Syringe (point style ) (point style ) N/A Point Style Small RN Small RN Small RN Small RN Small RN Large RN ACCESSORIES (Syringe not included) Reproducibility (Chaney) Adapter For Syringe Calibration Service, add the prefix "CAL" to the beginning of the syringe s part number. Note: Needles are 1 mm; Max temperature: Cemented Needle: 1 F (0 C) All others: 9 F (11 C); Max pressure:,000 PSI Hamilton Microliter Syringes 900 Series The 900 series has the same liquid handling capabilities as the 800 series but is a more economical version. The 900 series does not have any replaceable parts making the initial cost less than the 800 series. HAMILTON 900 SERIES Removable Needle Syringes & Repl Needles s "s" indicates added strength VOLUME µ L 10 µ L MODEL GAUGE 6s 6s Cemented Needle (N) Syringe (point style ) (point style ) Point Style Small RN Small RN ACCESSORIES (Syringe not included) Reproducibility (Chaney) Adapter For Syringe Calibration Service, add the prefix "CAL" to the beginning of the syringe s part number. Note: Needles are 1 mm; Max temperature: Cemented Needle: 1 F (0 C) Removable Needle: 9 F (11 C); Max pressure:,000 PSI Recommended Use: This syringe is perfect when a robust syringe is desired and budget is a consideration. Reproducibility (Chaney) Adapter Authorized Distributor

7 SYRINGES Hamilton Manual Syringes Hamilton Gastight Syringes 1700 Series HAMILTON 1700 SERIES Cemented Needle Syringes Removable Needle Syringes & Repl Needles Luer Tip Syringes & Repl Needles SL Syringes & Repl Needles PTFE Luer Lock Syringes & Repl Needles s "s" indicates added strength VOLUME 10 µl µl 0 µl 100 µl 0 µl 00 µl MODEL GAUGE 6s s s s s LENGTH 1 mm 1 mm 1 mm 1 mm 1 mm 1 mm Cemented Needle (N) Syringe (point style ) Cemented Needle (N) Syringe (point style ) Cemented Needle (N) Syringe (specify needle) (point style ) (point style ) Luer Tip (LT) Syringe SampleLock (SL) Syringe (point style ) PTFE Luer Lock (TLL) Syringe ChemSeal (C) (no needle available) Point Style Small RN Small RN Small RN Small RN Large RN Large RN Point Style Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub N/A N/A Point Style Large RN Large RN Large RN Large RN N/A N/A Point Style Metal Hub Metal Hub Metal Hub Metal Hub Metal Hub Metal Hub ACCESSORIES (Syringe not included) Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub PB600 Repeating Dispenser Reproducibility (Chaney) Adapter Syringe Guide Digital Base Unit Add "DS" to the beginning of the syringe s part number. (Base unit not sold separately) 1) LTN gauge ) s gauge ) gauge For Syringe Calibration Service, add the prefix "CAL" to the beginning of the syringe s part number. Note: Max temp: Cemented Needle: 1 F (0 C), All others: 9 F (11 C) Max Pressure: 0 00 µl: 00 PSI, SampleLock Syringes: 0 PSI, All others: 1,000 PSI 41 Chrom Tech your chromatography specialists

8 Hamilton Manual Syringes SYRINGES Hamilton Gastight Syringes 1000 Series HAMILTON 1000 SERIES Cemented Needle Syringes Removable Needle Syringes & Repl Needles Luer Tip Syringes & Repl Needles SL Syringes & Repl Needles PTFE Luer Lock Syringes & Repl Needles VOLUME 1 ml. ml ml 10 ml ml 0 ml 100 ml MODEL GAUGE LENGTH 1 mm 1 mm 1 mm 1 mm 1 mm 1 mm 1 mm Cemented Needle (LTN) Syringe (point style ) Cemented Needle (LTN) Syringe (point style ) Cemented Needle (LTN) Syringe (specify needle) (point style ) Luer Tip (LT) Syringe SampleLock (SL)Syringe (point style ) Point Style Large RN Large RN Large RN Large RN Point Style Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub Point Style Large RN Large RN Large RN Large RN Large RN Large RN Large RN PTFE Luer Lock (TLL) Syringe without slots PTFE Luer Lock (TLL) Syringe without flange, without slots ChemSeal (C) (no needle available) Point Style Metal Hub Metal Hub Metal Hub Metal Hub Metal Hub Metal Hub Metal Hub ACCESSORIES (Syringe not included) Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub PB600 Repeating Dispenser ) Needle is point style For Syringe Calibration Service, add the prefix "CAL" to the beginning of the syringe s part number. Note: Max temperature: Cemented Needle: 1 F (0 C), All others: 9 F (11 C) Max pressure: 1 10 ml: 00 PSI, All others: 100 PSI Authorized Distributor

9 SYRINGES Hamilton Manual Syringes Hamilton Gastight Syringes 1800 Series The 1800 series syringe is the Gastight version of the 800 series syringes. The 1800 series was designed to eliminate the possibility of plunger damage. It has the same liquid handling capabilities as the 1700 series but the extended plunger eliminates breakage and allows the user some control over the dispense speed. HAMILTON 1800 SERIES Removable Needle Syringes & Repl Needles s "s" indicates added strength VOLUME 10 µ L µ L 0 µ L 100 µ L 0 µ L MODEL GAUGE 6s s s s s (point style ) Point Style Small RN Small RN Small RN Small RN Large RN ACCESSORIES (Syringe not included) Reproducibility (Chaney) Adapter For Syringe Calibration Service, add the prefix "CAL" to the beginning of the syringe s part number. Note: Needles are 1 mm; Max temperature: Cemented Needle: 1 F (0 C) Removable Needle: 9 F (11 C); Max pressure: 1,000 PSI, except 0 µl: 00 PSI Gastight Syringes Polymer tip creates a leak-free seal for both liquids and gases Hamilton Gastight Syringes Super Syringe Super Syringes were designed primarily for air sampling, preparing gas standards, calibrating reservoirs, and pneumographs. The Super Syringe is the only Hamilton syringe with an acrylic barrel, which makes this syringe slightly less chemically resistant. HAMILTON SUPER SYRINGE VOLUME 0. L 1 L 1. L L MODEL S000 S1000 S100 S000 PTFE Luer Lock (TLL) Syringe Tracheal Adapter Note: Max temperature: 80 C (176 F); Max pressure: 0 PSI 414 Chrom Tech your chromatography specialists

10 Hamilton SYRINGES Hamilton (6/pk) HAMILTON HUB NEEDLES METAL HUB (N) KEL-F HUB (KF) GAUGE PT STYLE PT STYLE PT STYLE CUSTOM NEEDLES 1 PT STYLES,, 4 CUSTOM NEEDLES PT STYLES, AS PT STYLE PT STYLE PT STYLE CUSTOM NEEDLES 1 PT STYLES,, CUSTOM NEEDLES PT STYLES, AS 6s s HAMILTON REMOVABLE NEEDLES (RN) FOR. 100 µl SYRINGES GAUGE PT STYLE PT STYLE PT STYLE CUSTOM NEEDLES 1 PT STYLES,, CUSTOM NEEDLES PT STYLES, AS FOR 0 µl 10 ml SYRINGES PT STYLE PT STYLE PT STYLE CUSTOM NEEDLES 1 PT STYLES,, 4 CUSTOM NEEDLES PT STYLES, AS 6s s ) Please specify length and point style ) Please specify length (Point style ) Authorized Distributor distributed by

11 SYRINGES Hamilton Syringe Accessories Hamilton Syringe Accessories PB600 Repeating Dispenser Consistently dispense sample up to 0 times with the push of a button. The repeating dispenser works with Microliter or Gastight syringes from 10 µl to 10 ml. USE THIS SYRINGE VOLUME Digital Syringe The only N.I.S.T. traceable, calibrated syringe device available. It comes completely calibrated with its own "Certificate of Calibration". The easy-to-read LCD screen displays volume dispensed within ±0.% of the syringe volume. It is used with Hamilton syringes with total volumes of 0. to 00 µl. Reproducibility (Chaney) Adapter For consistent, reproducible injections. It also prevents the plunger from bending. The adjustable stop prevents plunger damage. Easily installed. Syringe Guide The Syringe Guide is a cost effective plunge support device. With only two guide arms the Syringe Guide protects the plunger from damage but should not be used to improve accuracy and precision. µl PER DISPENSE 10 µl 0. µl µl 0. µl 0 µl 1 µl 100 µl µl 0 µl µl 00 µl 10 µl 1 ml 0 µl. ml 0 µl ml 100 µl 10 ml 00 µl MTB Sampling Valve Lever-actuated on/off valve for storing and transporting samples in any Gastight TLL syringe PART NO Kel-F hub needles attach to the valve Pressure tested to 100 PSI; autoclavable Bore I.D., 0.09" Septum Adapter Store and sample syringe contents through the Septum Adapter Attaches to any TLL syringe or luer lock fitting Replaceable septum Removable (RN) Adapters DESCRIPTION 8680 MTB Sampling Valve PART NO DESCRIPTION 1 Septum Adapter (TLL), includes 1 septa 7810 Replacement Septa, 7 mm dia, 1/pk For 0 µl and larger removable needle (RN) syringes Port ID of.09" allows sample spiking with a 701N syringe Provides connection to threaded fittings, tubing assemblies, tees and crosses PART NO DESCRIPTION 080 Male Luer/Removable Needle Hub (L) 081 Female Luer/Removable Needle Hub (L) 08 Male Luer Lock/Removable Needle Hub (L) Calibrated Syringe Hamilton Company offers a calibration service for precision syringes and Digital Syringes. A Certificate of Calibration is provided with the product and the procedure is performed with an unbroken chain of calibrations traceable to N.I.S.T. procedure 416 Chrom Tech your chromatography specialists

12 Hamilton Syringe Cleaning & Maintenance SYRINGES Hamilton Syringe Cleaning & Maintenance Syringe Cleaner Clean 7000 Series Modified Microliter syringes with only heat (70 C) or add a vacuum source (0.1 mm mercury) to remove suspected residuals Microliter and Gastight syringes may be cleaned when a voltage rheostat* is added to reduce the chamber temperature to 0 C; a vacuum source (0.1 mm mercury) can be added to remove suspected residuals Not effective for frozen plungers or plugged needles PART NO DESCRIPTION Syringe Cleaner, 10VAC 7661 Syringe Cleaner, 0VAC 760 Replacement Septa, mm diameter, 1/pk * Note: Voltage rheostat and vacuum source must be purchased separately Syringe Cleaning Tips To clean the plunger, remove it from the syringe barrel and gently wipe with a lint-free tissue. Reinsert the plunger into the barrel and pump deionized water or acetone through the needle and syringe. Air dry the syringe for storage. Needle Cleaning Kit Contains a selection of various diameter tungsten wires for cleaning plugged needles Biodegradable cleaning concentrate helps to remove tenacious residues PART NO DESCRIPTION 1811 Cleaning Concentrate, 00 ml (not included in cleaning kit) HAMILTON CLEANING WIRES PART NO CLEANING WIRES (7" IN LENGTH) USE TO CLEAN NEEDLE GAUGES " O.D., 10/pk s, 6s, " O.D., 10/pk 6s, " O.D., 10/pk s, s, " O.D., 10/pk " O.D., 10/pk " O.D., 10/pk, (and larger) Needle Cleaning Tips Should a needle become clogged, do not attempt to clean it by forcing liquid or compressed air through the syringe. Excessive pressure will split the glass barrel. Remove the plunger from the syringe before cleaning the needle. Cleaning wires are used to dislodge any foreign material or residue build-up. Use deionized water or acetone to thoroughly rinse the syringe. Authorized Distributor

13 SYRINGES LC Autosampler Syringes Hamilton CTC LC Autosampler Syringes FEATURES ADVANTAGES/BENEFIT S LINE C LINE X TYPE Inert PTFE-Polymer Plunger Tip Inert PTFE-Polymer Plunger Tip Unique plunger and flange design High mechanical stability for increased syringe lifetime. Compatible with organics, and high as well as low ph solutions. Ensures reliable installation and alignment of the plunger and barrel X X X X X X Needle attached directly to the barrel Minimizes carryover X X No glue or cement in fluid path Deactivated needle and barrel Deactivated needle and barrel Deactivated needle and barrel Better solvent compatibility longer syringe life Prevents sample adsorption on inner surface of the barrel Extremely smooth surface for low friction and increased plunger lifetime Eliminates contact between samples and metal components X X X X X X X Adjustable button to prevent plunger damage New flange design for accurate syringe installation X-Type 100X zoom Coated glass Improved needle hub design for zero carryover Color-coded hub for quick needle volume identification Uncoated Glass Microscope view confirms the very smooth inner surface of the coated X-Type glass barrel. HAMILTON SYRINGES FOR CTC/LEAP LC AUTOSAMPLERS VOLUME TYPE 10 µl µl 0 µl 100 µl 100 µl 0 µl 00 µl 1000 µl 00 µl 000 µl HAMILTON CTC PAL HTC-xt, HTS-xt AND HTX-xt LC AUTOSAMPLER SYRINGES MODEL "s" indicates GAUGE s added strength s s s Cemented (N) Needle (point style ) Fixed Needle (FN) (point style ) Fixed Needle (FN) (point style ) HAMILTON CTC LEAP A00S LC AUTOSAMPLER SYRINGES Cemented (N) Needle (point style ) Note: Needles are 1 mm 1 LTN Termination Slimline Syringe S C X S TECH TIP Related Product Inlet Needle Sleeves Designed to fit CTC PAL Autosamplers PART NO DESCRIPTION QTY CT-NS Inlet Needle Sleeve /pk CT-NS-0 Inlet Needle Sleeve 0/pk 418 HAMILTON AUTOSAMPLER SYRINGES VOLUME µl 0 µl 100 µl 0 µl 00 µl 1000 µl 00 µl 000 µl MODEL GAUGE No needle No needle No needle No needle No needle No needle No needle No needle FOR THERMO SCIENTIFIC AS 100/00 & AS 1000/000/00 ChemSeal (C) Syringe FOR SPARK HOLLAND* ChemSeal (C) Syringe FOR PERKINELMER SERIES 00 ChemSeal (C) Syringe The Hamilton Spark Holland syringe line works with the following manufacturers autosamplers: Spark Holland Midas, Triathlon, Endurance and Alias, Antec AS 100 and AS 110, Dionex ESA Model 4, 40 and 40MT, Beckman Coulter 08, and Grace/Alltech Model 80. Chrom Tech your chromatography specialists

14 LC Autosampler Syringes SYRINGES Hamilton Syringes for Most Manual HPLC Valves Point style, or s gauge needle For IDEX valves (Rheodyne & Upchurch), Valco, Beckman Coulter, Altex and SSI Injection Valve Syringes HAMILTON 700 SERIES MANUAL SYRINGES s "s" indicates added strength HAMILTON 1700 SERIES MANUAL SYRINGES VOLUME 10 µl µl 0 µl 100 µl 0 µl 00 µl MODEL GAUGE s s s s Cemented Needle (N) Syringe VOLUME 10 µl µl 0 µl 100 µl 0 µl 00 µl MODEL GAUGE s s s s s Cemented Needle (N) Syringe N/A Luer Tip (LT) Syringe PTFE Luer Lock (TLL) Syringe Point Style Small RN Small RN Small RN Small RN Large RN Large RN N/A N/A Point Style Metal Hub Metal Hub Metal Hub Metal Hub Metal Hub Metal Hub For Syringe Calibration Service, add the prefix "CAL" to the beginning of the syringe s part number. Note: Needles are 1 mm 1) gauge ) LTN Termination Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub Kel-F Hub Hamilton Syringes for Valco VISF-1 Valves HAMILTON SYRINGES FOR VALCO VISF-1 INJECTION VALVE s "s" indicates added strength *Please specify length and point style Note: Needles are 19 mm VOLUME µl 0 µl 100 µl 0 µl 000 µl µl MODEL GAUGE s s s s (point style ) 6/pk Point Style * Authorized Distributor

15 SYRINGES GC Autosampler Syringes Hamilton Syringes for Agilent GC Instrumentation s "s" indicates added strength ASN AUTOSAMPLER CEMENTED NEEDLE HP 769/768/HP 767 HP 7670,7671, 767 ASRN AUTOSAMPLER REMOVABLE NEEDLE (N) CEMENTED NEEDLE (RN) REMOVABLE NEEDLE MODEL VOLUME GAUGE/LENGTH/PT STYLE s 6s -6s s 6s -6s 6s 6s MICROLITER SYRINGES µL x/1.71"/hp µL x/1.71"/hp µl x/1.71"/hp , 6/pk µl x/1.71"/hp µl x/"/ µL x/1.71"/hp , 6/pk 10µL x/1.71"/hp µL x/1.71/ µL x/"/ , 6/pk 10µL x/"/ 8066 GASTIGHT SYRINGES 17 µl x/1.71"/hp , 6/pk µl x/1.71"/hp µL x/1.71"/hp , 6/pk 10µL x/1.71"/hp µL x/"/ Hamilton Syringes for Thermo Scientific Autosampler Syringes HAMILTON SYRINGES FOR THERMO SCIENTIFIC AS 800, AS 000 s "s" indicates added strength Note: Needles are 80 mm VOLUME 10 µl MODEL 701 GAUGE Cemented Needle (N) Syringe (point style AS) 6s 8018 HAMILTON SYRINGES FOR THERMO SCIENTIFIC HEADSPACE HS 0/00/80 Note: Needles are 6 mm VOLUME 00 µl MODEL 100 GAUGE Cemented Needle (LTN) Syringe (point style ) 0660 Thermo Scientific Finnigan AS 000 Autosampler HAMILTON SYRINGES FOR THERMO SCIENTIFIC AI/AS 000 TRI PLUS SYRINGES s "s" indicates added strength Note: Needles are 0 mm VOLUME µl 10 µl MODEL GAUGE 6s 6s Cemented Needle (N) Syringe (point style AS) Cemented Needle (N) Syringe (point style ) Chrom Tech your chromatography specialists

16 GC Autosampler Syringes SYRINGES Hamilton Syringes for Shimadzu Autosampler HAMILTON SYRINGES FOR SHIMADZU AOC-9 s "s" indicates added strength Note: Needles are 1 mm VOLUME µl 10 µl MODEL GAUGE 6s 6s (point style ) HAMILTON SYRINGES FOR SHIMADZU AOC-14/AOC-17/AOC-0 s "s" indicates added strength Note: Needles are 4 mm VOLUME µl 10 µl MODEL GAUGE s s (point style ) Shimadzu AOC-14 Autosampler Hamilton CTC GC Autosampler Syringes FEATURES ADVANTAGES/BENEFIT S LINE C LINE Inert PTFE-Polymer Plunger Tip Inert PTFE-Polymer Plunger Tip Unique plunger and flange design High mechanical stability for increased syringe lifetime. Compatible with organics, and high as well as low ph solutions. Ensures reliable installation and alignment of the plunger and barrel Needle attached directly to the barrel Minimizes carryover X No glue or cement in fluid path Better solvent compatibility longer syringe life X X X X X X HAMILTON SYRINGES FOR CTC/LEAP GC AUTOSAMPLERS VOLUME TYPE µl 10 µl 10 µl 10 µl µl µl µl 100 µl 100 µl HAMILTON CTC PAL GC-xt AND Combi PAL-xt GC AUTOSAMPLER SYRINGES MODEL "s" indicates GAUGE s added strength 6s 6s s s s 6s 6s 6s Cemented (N) Needle (point style AS) Fixed Needle (FN) (point style AS) Note: Needles are 1 mm 1 PT Style Slimline Syringe S C , , HAMILTON SYRINGES FOR CTC/LEAP GC HEADSPACE AUTOSAMPLERS VOLUME TYPE 1.0 ml 1.0 ml. ml. ml.0 ml HAMILTON CTC PAL GC-xt AND Combi PAL-xt GC AUTOSAMPLER SYRINGES MODEL GAUGE 6 6 Luer Tip Cemented (LTN) Needle (point style ) Note: Needles are 1 mm HD Authorized Distributor

17 SYRINGES Hamilton Pipettes Hamilton SoftGrip Pipettes Single Channel Wide selection of ergonomic pipettes Completely autoclavable Guaranteed accuracy and precision SoftGrip pipettes routinely receive the highest user satisfaction score of 10 on 11 different aspects of a pipette, including plunger and eject forces, weight, diameter, and texture. Choose from six adjustable volume and ten fixed volume SoftGrip pipettes covering 0. µl to 1 ml. All pipettes have color-coded plunger buttons and labels for easy volume identification. SoftGrip air-displacement pipettes are built from high quality, state-of-the-art materials designed to provide years of reliable service. All pipettes are completely autoclavable for easy decontamination and sterilization without the need for disassembly and recalibration. The isolated volume ring prevents accidental volume changes. A magnified, easy-to-read micrometer ensures reproducible, accurate volume setting. Each pipette meets or exceeds industry standards for accuracy and precision when used with Hamilton Universal AdvanTip Precision Pipette Tips. HAMILTON SOFTGRIP ADJUSTABLE VOLUME PIPETTES, 0. µ L 1 m L PART NO VOLUME INCREMENTS (µl) COLOR AT 10% OF PIPETTE VOLUME ACCURACY WITHIN ±% PRECISION WITHIN % AT 100% OF PIPETTE VOLUME ACCURACY WITHIN ±% µl 0.00 Aqua µl 0.0 Purple µl 0.0 Forest Green µl 0. Violet µl 0. Brick Red µl 1 ml.0 Sky Blue PRECISION WITHIN % HAMILTON SOFTGRIP FIXED VOLUME PIPETTES, µ L 1 m L AT 100% OF PIPETTE VOLUME PART NO VOLUME COLOR ACCURACY WITHIN ±% PRECISION WITHIN % µl Steel Blue µl Purple µl Forest Green µl Sandstone µl Violet µl Mustard µl Burnt Orange µl Brick Red µl Olive Green ml Sky Blue HAMILTON SINGLE CHANNEL PIPETTE ACCESSORIES PART NO PRODUCT DESCRIPTION Single channel pipette carousel Constructed of heavy, solvent-resistant plastic; holds six single and multi-channel pipettes Calibration labels, 10/pk Quickly record and view calibration data with labels on your pipettes 400 Calibration key For simple calibration in the field Chrom Tech your chromatography specialists

18 Hamilton Pipettes SYRINGES Hamilton SoftGrip Pipettes Multi-Channel Easily Adjusts for Left-Hand Operation Completely Autoclavable Guaranteed Accuracy and Precision Hamilton SoftGrip pipettes are available as 8-channel and 1-channel adjustable volume manual pipettes in two volume ranges covering µl to 0 µl and 0 µl to 00 µl. The pipettes have color-coded plunger buttons and labels for quick volume identification. The unique, long tip ejector lever and movable lower body can be rotated a full 60º relative to the handle to provide maximum comfort for left- or right-handed use. Additionally, the easily activated tip ejector lever releases all the tips in single stroke. Made of the finest materials, the entire SoftGrip multi-channel pipette can be autoclaved without the need for disassembly or recalibration. Accuracy and precision is guaranteed when used with Hamilton Universal AdvanTip Precision Pipette Tips. HAMILTON SOFTGRIP MULTI-CHANNEL PIPETTES, 8-CHANNEL, µ L 00 µl PART NO VOLUME INCREMENTS (µl) COLOR AT 10% OF PIPETTE VOLUME ACCURACY WITHIN ±% PRECISION WITHIN % AT 100% OF PIPETTE VOLUME ACCURACY WITHIN ±% µl x Sandstone µl x 8 0. Brick Red PRECISION WITHIN % HAMILTON SOFTGRIP MULTI-CHANNEL PIPETTES, 1-CHANNEL, µ L 00 µl PART NO VOLUME INCREMENTS (µl) COLOR AT 10% OF PIPETTE VOLUME ACCURACY WITHIN ±% PRECISION WITHIN % AT 100% OF PIPETTE VOLUME ACCURACY WITHIN ±% µl x Sandstone µl x 1 0. Brick Red PRECISION WITHIN % HAMILTON MULTI-CHANNEL PIPETTE ACCESSORIES PART NO PRODUCT DESCRIPTION 419 Multi-Channel Pipette Stand Constructed of heavy, solvent-resistant plastic; holds one multi-channel pipette Calibration labels, 10/pk Quickly record and view calibration data with labels on your pipettes 400 Calibration key For simple calibration in the field Authorized Distributor

19 SYRINGES Hamilton Pipettes Hamilton Universal AdvanTip LT & Precision Pipette Tips 10 µl Pipette Tips Volume Range µl Recommended for,, and 10 µl pipettes HAMILTON 10 µ L PIPETTE TIPS LOW RETENTION STANDARD DESCRIPTION TOTAL TIPS Bulk, 1,000 tips/bag 1, Bulk, Extended Length, 1,000 tips/bag 1, Racked, 96 tips/rack 1, Racked, Extended Length, 96 tips/rack Racked, Pre-Sterilized, 96 tips/rack Racked, Filter, Pre-Sterilized, 96 tips/rack 1, Racked, Extended Length, Filter, Pre-Sterilized, 96 tips/rack Stacked Rack, 96 tips/rack, racks/stack µl Pipette Tips Volume Range 00 µl Recommended for 0,, 0, 100, and 00 µl pipettes. Also can be used with 00 µl pipettes when pipetting volumes of 00 µl or less HAMILTON 00 µ L PIPETTE TIPS LOW RETENTION STANDARD DESCRIPTION TOTAL TIPS Racked, 96 tips/rack Racked, Pre-Sterilized, 96 tips/rack Racked, Filter, Pre-Sterilized, 96 tips/rack µl Pipette Tips Volume Range 00 µl Recommended for 0 and 00 µl pipettes HAMILTON 00 µ L PIPETTE TIPS LOW RETENTION STANDARD DESCRIPTION TOTAL TIPS Bulk, 1,000 tips/bag 1, Racked, 96 tips/rack Racked, Pre-Sterilized, 96 tips/rack Racked, Filter, Pre-Sterilized, 96 tips/rack ml Pipette Tips Volume Range 100 1,000 µl Recommended for 00 and 1,000 µl pipettes HAMILTON 1 m L PIPETTE TIPS LOW RETENTION STANDARD DESCRIPTION TOTAL TIPS Bulk, 1,000 tips/bag 1, Racked, 96 tips/rack Racked, Pre-Sterilized, 96 tips/rack Racked, Filter, Pre-Sterilized, 96 tips/rack Chrom Tech your chromatography specialists

20 Hamilton Pipettes SYRINGES Hamilton SofTop Quick Dispenser Adjustable volume bottle top dispensing Maximum chemical and thermal resistance with ceramic plunger Fast and accurate micrometer volume adjustment The SofTop Quik Dispenser is safe and easy-to-use with an exceptional soft touch and sure-grip ergonomic design. Calibrated volumetric steps assure identical volume delivery every time. The graduated gauge offers user-independent reproducible volume delivery. With an innovative plunger made of aluminum oxide ceramic, there is no chance of abrasions, scratching, swelling, or flaking of a coating layer. The SofTop Quik Dispenser has a screw-fitted suction hose, eliminating the possibility of air bubbles during aspiration. The fully autoclavable SofTop Quik Dispenser is available in six versions from 0. ml to 60 ml. Each dispenser is individually tested and shipped with a Certificate of Quality. HAMILTON SOFTOP QUICK DISPENSER PART NO DESCRIPTION SofTop Quik Dispenser, ml SofTop Quik Dispenser, ml SofTop Quik Dispenser, 10 ml SofTop Quik Dispenser, 0 ml SofTop Quik Dispenser, ml Dispensing Nozzle for SofTop Quik Dispensers up to 10 ml Dispensing Nozzle for SofTop Quik Dispensers 0 ml and 60 ml Suction Tube for SofTop Quik Dispensers up to 10 ml, 1" Suction Tube for SofTop Quik Dispensers 0 ml and 60 ml, 1" Authorized Distributor

21 SYRINGESHamilton Microlab 600 Benefits of the Hamilton Microlab 600 Reduce time preparing samples or dispensing reagents Minimize experimental variation from one user to the next Manage log files from any PC Comply with EPA, FDA GLP and GMP, 1 CFR Part 11, and ISO N.I.S.T. traceable calibration The Microlab 600 offers labs a way to securely monitor processes and greatly increase efficiency. No more adjusting pipettes and recalculating dilutions. Quickly recall stored dispenses and dilutions with Favorites. Trigger the hand probe or tap the foot switch to actuate the syringe drives according to a predefined program. Hamilton Dual Syringe Diluters How Does it Work? Step 1. Program sample and diluent volume. Step. Trigger the hand probe to fill left syringe with diluent and aspirate sample into the hand probe with the right syringe. Sample is isolated in the dispense tubing Step. Trigger the hand probe to dispense the sample and then the diluent into the vial to complete the dilution and wash the tube for the next sample. Concentrated Sample 1/ 1/ 1/10 1/100 1/1,000 1/10,000 Diluent Concentrated Sample HAMILTON DUAL SYRINGE DILUTERS PART NO DESCRIPTION CONCORDE HAND PROBE ML61-DIL Dual Syringe Diluter with Basic Controller ML6-DIL Dual Syringe Diluter with Advanced Controller DISPOSABLE TIP HAND PROBE ML6-DTHP Microlab 600 Diluter with Disposable Tip Hand Probe CLICKSURE TIPS FOR DTHP 7 0 µl, non-sterile ClickSure Tips, 960 tips, racked 4 0 µl, non-sterile ClickSure Tips, 960 tips, bulk 6 0 µl, sterile ClickSure Tips, 960 tips, racked 9 1 ml, non-sterile ClickSure Tips, 960 tips, racked 4 1 ml, non-sterile ClickSure Tips, 960 tips, bulk 8 1 ml, sterile ClickSure Tips, 960 tips, racked The- -DIL model ships with the Concorde hand probe, universal valves, fill/dispense tubing, accessory holder, country-specific power cord, and the choice of two syringes. If syringes are not selected at the time of order,. ml and 0 µl syringes are included. The -DTHP model ships with the Disposable Tip Hand Probe, universal valves, fill tubing, Cable Management System, country-specific power cord, and the choice of two syringes. If syringes are not selected at the time of the order,. ml and 0 μl syringes are included. 0 µl ClickSure Tip 1 ml ClickSure Tip 46 Chrom Tech your chromatography specialists

22 Hamilton Microlab 600 SYRINGES Hamilton Dual Syringe Diluters (cont.) Dilution Wizard Dual Syringe Dilution 1 Fill with diluent from the reservoir Aspirate sample into the hand probe Dispense sample and diluent Serial Dilution (Programmed) Repeat the steps for single or dual dilution with varying dilution ratios and the same final volume. 1 1/10 Serial Dilution (Tube to Tube) 1/ 1/0 4 1/100 1 Sample 1/10 1/ /1000 Repeat the steps for single or dual dilution and use the resulting dilution as the sample for the next dilution. Multi Sample Dilution (or Internal Standard Addition) 1 Fill with diluent from the reservoir Aspirate sample into the hand probe Aspirate standard into the hand probe 4 Dispense standard, sample, and diluent Dilution Options Single Sample Dilution The trigger is pressed and the sample is aspirated into the tip using the right syringe while diluent is drawn into the left syringe. The trigger is pressed again and the sample is dispensed from the tip. The tip is ejected. 4 Another trigger dispenses the diluent to complete the dilution. Multi- Sample Dilution Aspirate Sample 1 into ClickSure Tip. Aspirate Sample. Repeat with additional solutions. Dispense Samples. 4 Discard ClickSure Tip. Dispense Diluent. Authorized Distributor

23 SYRINGESHamilton Microlab 600 Hamilton Dispensers The Microlab 600 is able to dispense volumes from 100 nl to 0 ml. The Microlab 600 uses positive displacement syringes to accurately dispense volatile, viscous, and dense liquids independent of atmospheric influences. The inert fluid path is compatible with harsh chemicals, making the Microlab 600 the most reliable and robust dispensing system available. Icon Key Valve HAMILTON DISPENSERS PART NO DESCRIPTION ML610-DIS Single Syringe Dispenser with Basic Controller ML60-DIS Single Syringe Dispenser with Advanced Controller ML61-DIS Dual Syringe Dispenser with Basic Controller ML6-DIS Dual Syringe Dispenser with Advanced Controller ML61-CNT Dual Syringe Continuous Dispenser with Basic Controller ML6-CNT Dual Syringe Continuous Dispenser with Advanced Controller Reservoir Color Guide Reagent 1 / System Fluid Reagent Sample Titration Endpoint Hand Probe Syringe Types of Dispensers Single Syringe Dispenser The syringe fills from a reservoir and dispenses from the hand probe. Dual Syringe Dispenser Each syringe fills from a separate reservoir and dispenses separately from the hand probe. Continuous Dispenser One syringe fills while the other syringe is dispensing from the same reservoir. 48 Chrom Tech your chromatography specialists

24 Hamilton Microlab 600 SYRINGES Hamilton Dispensers (cont.) Dispenser Options Aliquot Dispense Aliquot Wizard Dispense Wizard Single Syringe Aliquot Single Syringe Aliquot Aliquot Dispense Wizard Repetitively dispense aliquots of the same volume at Aliquot Dispense Aliquot Wizard Dispense Wizard the press of a button. Single Syringe Aliquot or Serial Dispense Aliquot Dispense Wizard 1 Fill from reservoir 1 Fill from reservoir Single Syringe Aliquot Single Syringe Aliquot Single Syringe Aliquot 1 Dual Syringe Aliquot Dual Syringe Aliquot Dual Syringe Aliquot Dual Syringe Aliquot Dispense through hand probe Dispense through hand probe Dispense 4 Dispense 4 4 Dispense 4 Dispense Serial Dispense Wizard Repetitively dispense aliquots of differing volumes at the press of a button. Dual Syringe Aliquot or Serial Dispense 1 Dual Syringe Aliquot Titration Wizard Slowly add liquid to another liquid until an end-point is reached. An example of this application is adding acid or base to a ph buffer. Pipette Wizard Simulate a manual pipette used to transfer liquid from one vessel to the next. Titration A large initial volume is dispensed to get close to the endpoint. Then a smaller step volume is dispensed until the endpoint is reached. 1 Fill from reservoirs Dispense the initial volume Dispense the step volume Pipette Aspirate sample into the hand probe Dispense sample from the hand probe Authorized Distributor

25 SYRINGESHamilton Microlab 600 Hamilton Microlab 600 Specifications CONTROLLER SPECIFICATIONS Screen size Screen resolution Tilt positions Mounting options Program memory Communication type Power rating Dimensions Weight.7" (1 cm diagonal) 640 x 480 pixels positions from 90 to flat On top of the syringe pump, bench top, or wall mount GB (with Advanced upgrade) Ethernet, 10/100 BASE-T 4 VDC,. A.9" x 6." x 7" (7. x 16.1 x mm) in down position 1.9 lbs (0.86 kg) SINGLE AND DUAL SYRINGE PUMP SPECIFICATIONS Accuracy +/- 1% Precision +/- 0.% Syringe drive mechanism Flow rate Syringe resolution Compatible syringes Volume range Fluid path Communication type Communication protocol Pump memory Calibration Certifications Power requirements Power rating Dimensions Weight 1.8 stepper motor with variable volumetric flow rate µl/second (depending on the syringe that is selected) 0.00% of the nominal syringe volume 10,, 0, 100, 0, 00 µl, 1,.,, 10, and 0 ml BFP Syringes 1.0 µl - 0 ml Borosilicate, PTFE, CTFE Ethernet, 10/100 BASE-T.NET.0 Application Programming Interface (API) One method stored in non volatile memory Factory tested and traceable to N.I.S.T. standards CE, CSA V 1. A max 0160 Hz 4 VDC,. A 7 x. x 10. inch (177.8 x 19.7 x 66.7 mm) 1 lbs (.9 kg) 1 Fanless heat vent 1 4 volt power input 1 4 CAN daisy chain input/output RS- console port 4 6 Power over Ethernet (PoE) TTL input/output 6 1 Memory Slot 4 Ethernet 6 Optional Power Input Host USB for Mouse, Keyboard, 6 Printer, and Barcode Scanner Slave USB Port Optional RS High torque valve motors 4 Precision syringe drives with 48,000 step resolution over 60 mm Limited power and prime buttons Independent left and right trigger points 40 Chrom Tech your chromatography specialists

26 Hamilton Microlab 600 SYRINGES Microlab Software Choosing a Controller Hamilton conducted human factor studies to create a clear and understandable system that is communicated through a straightforward user interface. Each screen was thoughtfully designed to simplify the flow of each process and maximize its ease of use. Basic Controller The Basic Microlab 600 controller quickly performs standard dilutions and dispensing using a Quick Start screen. Advanced Controller The Advanced controller contains a significant number of additional features and allows users to create methods using air gaps, washing, repetitive dispensing, and more. For users with the Basic controller that would like to upgrade, it can be easily converted to the Advanced using a simple software kit (P/N ). BASIC & ADVANCED FUNCTIONALITY COMPARISON FEATURES BASIC ADVANCED Quick Start Screen Prime the instrument, program the dispense volume, and start dispensing Graphical Pump Status Animations of the fluid path display the current and future state of the syringe pump Adaptive Dispense Control Adjust dispense volumes in mid-process and the instrument will recalculate the remaining dispenses and proper time to refill Configuration Guide Step-by-step help to set up the instrument Wizards Dedicated Wizards for aliquot dispensing, serial dispensing, dilution, pipetting, and titration Favorites Menu Quickly access frequently used methods Custom Method Programming Create custom applications not covered by a Wizard Enhanced Security Meet 1 CFR Part 11 and FDA GMP/GLP requirements using custom security options Method Storage Create and run more than 1,000 methods on a single controller Log File Creation Create and store files on a memory card, or permanently on a PC using LyncStore, to meet hardcopy archive requirements Language Options Operate the instrument in 10 languages Software Upgrades Download software updates and receive exciting new features Hamilton Microlab 600 Ordering Information HAMILTON DUAL SYRINGE DILUTERS PART NO DESCRIPTION CONCORDE HAND PROBE ML61-DIL Dual Syringe Diluter with Basic Controller ML6-DIL Dual Syringe Diluter with Advanced Controller DISPOSABLE TIP HAND PROBE ML6-DTHP Microlab 600 Diluter with Disposable Tip Hand Probe CLICKSURE TIPS FOR DTHP 7 0 µl, non-sterile ClickSure Tips, 960 tips, racked 4 0 µl, non-sterile ClickSure Tips, 960 tips, bulk 6 0 µl, sterile ClickSure Tips, 960 tips, racked 9 1 ml, non-sterile ClickSure Tips, 960 tips, racked 4 1 ml, non-sterile ClickSure Tips, 960 tips, bulk 8 1 ml, sterile ClickSure Tips, 960 tips, racked HAMILTON DISPENSERS PART NO DESCRIPTION ML610-DIS Single Syringe Dispenser with Basic Controller ML60-DIS Single Syringe Dispenser with Advanced Controller ML61-DIS Dual Syringe Dispenser with Basic Controller ML6-DIS Dual Syringe Dispenser with Advanced Controller ML61-CNT Dual Syringe Continuous Dispenser with Basic Controller ML6-CNT Dual Syringe Continuous Dispenser with Advanced Controller Authorized Distributor

27 SYRINGESHamilton Microlab 600 Hamilton Microlab 600 Replacement Parts Syringes Select the smallest syringe with a maximum volume that is greater than the largest volume to be dispensed. Ideally the smallest volume to be dispensed should fall within the optimal ranges listed to the left. The Microlab 600 can dispense volumes below the optimal range but there will be some impact on accuracy and precision. The SaltLine Syringes should be used when working with solutions that have a high salt concentration. HAMILTON SYRINGES PART NO SYRINGE SIZE OPTIMAL RANGE STANDARD SYRINGES μl 1 10 μl μl. μl μl 0 μl μl μl μl 0 μl μl 0 00 μl ml 100 μl 1.0 ml ml 0 μl. ml ml 00 μl.0 ml ml ml ml..0 ml ml 0.0 ml SALTLINE SYRINGES 08 1 ml 100 μl ml 086 ml 00 μl -.0 ml ml ml Power Supply & Power Cords HAMILTON POWER SUPPLY & POWER CORDS PART NO DESCRIPTION DIAGRAM OF PLUG POWER SUPPLY Power Supply Universal (110 0 VAC) N/A POWER CORDS Continental Europe, Russia, Schuko 89-0 Australia, New Zealand, Argentina, China 89-0 UK, Ireland, Malaysia, Middle East 89-0 Power Cord USA, Canada, Mexico, Central America, Brazil, Japan Hamilton Valves, Tubing, Upgrade Kits & Miscellaneous Accessories Universal Valves & Accessories HAMILTON UNIVERSAL VALVES & ACCESSORIES PART NO VALVE ASSEMBLY Left Valve Assembly Right Valve Assembly Valve Cross Tube Assembly Valve Plug Valve Plugs PTFE Tubing Assemblies HAMILTON PTFE TUBING ASSEMBLIES PART NO GAUGE TYPE LENGTH Misc. Accessories INTERNAL VOLUME Fill Tubing 48" (119 mm) 1.1 ml Dispense Tubing 4" (17 mm) 1.9 ml Fill Tubing Custom Length 0.94 µl/mm Dispense Tubing Custom Length 0.94 µl/mm Fill Tubing 48" (119 mm) 4.7 ml Dispense Tubing 4" (17 mm).1 ml Fill Tubing Custom Length.7 µl/mm Dispense Tubing Custom Length.7 µl/mm Continuous Fill Tubing 0.94 µl/mm Continuous Fill Tubing.7 µl/mm Upgrade Kit Cross Tube HAMILTON UPGRADE KIT PART NO UPGRADE KIT INCLUDES Basic to Advanced Controller Upgrade Kit Custom Programmer Kit (Compatible with Microsoft.NET.0 and higher) Left Valve Fill & Dispense Tubing (Dispense tubing has tapered end) Advanced manual, GB SD card, SD to USB converter, and programmer software CD Programmer software CD with manual, Application Programming Interface, and example LabView, Visual C# and Visual Basic programs. Accessory Holder & Wire Stand Tubing Clips Right Valve 4 Power Supply Chrom Tech your chromatography specialists HAMILTON UNIVERSAL VALVES & ACCESSORIES PART NO DESCRIPTION Tubing Clips (/pk) Accessory Holder & Tubing Wire Stand Cable Management System

28 Hamilton Microlab 600 SYRINGES Hamilton Hand Probes, Foot Switch & Printer Kit HAMILTON AIRSHIELD, HAND PROBES, FOOT SWITCH AND PRINTER KIT PART NO DESCRIPTION Luer Lock Conversion Kit Concorde CT Hand Probe Dual Push Button Hand Probe Disposable Tip Hand Probe ( μl)* Large Volume Disposable Tip Hand Probe (1 - ml) 770 ml Disposable Tips (0/pk) Foot Switch AirShield AirShield Tubing (includes tubing clamp) Microlab Printer * Tips for this probe can be found on page Luer Lock Conversion Kit (Standard with the Dual Syringe Dispenser) (Standard with the Single Syringe Dispenser, Dual Syringe Diluter, and Continuous Dispenser) (0. 1,000 µl) (1 ml) For sensitive applications, the sample is aspirated into a disposable plastic tip which is thrown away between each sample, eliminating any change for carryover The AirShield is a separate accessory that can be purchased for any Microlab 600 instrument. It creates a positive pressure blanket of fresh air inside the pump that pushes air out over critical components on the outside of the pump, protecting them from the environment. Hamilton Standalone Syringe Pumps Take full command of your diluting and dispensing applications with the Microlab 600 standalone syringe pump. The standalone syringe pump allows you to custom program methods and deploy commands to any instrument on your network from anywhere in the world. HAMILTON STANDALONE PUMP PART NO DESCRIPTION ML60 Single Syringe Pump ML6 Dual Syringe Pump All standalone pumps ship complete with a universal valve(s), country-specific power cord, Custom Programmer kit, and choice of syringes. If no syringe(s) is/are selected at the time of the order 1 ml syringe(s) will be included automatically. Authorized Distributor

Selecting The Right Syringe

Selecting The Right Syringe Selecting The Right Syringe Choosing the Right Hamilton Syringe for Your Application 1. Is your sample a gas or a liquid? For a gas sample, use a GASTIGHT syringe. GASTIGHT 1000, 1700 and 1800 Series 1000/1700

More information

Hamilton Syringes. LT N LTN RN TLL TLL with slots. Hamilton Syringe Types Microliter. Hamilton Point Styles

Hamilton Syringes. LT N LTN RN TLL TLL with slots. Hamilton Syringe Types Microliter. Hamilton Point Styles Hamilton LT N LTN RN TLL TLL with slots Hamilton Point Styles Pt. 2 Pt. 3 Pt. 5 Pt. HP Hamilton syringes are designed as precision measuring instruments, and find wide use for sample introduction into

More information

Liquid Chromatography Syringes

Liquid Chromatography Syringes Liquid Chromatography Syringes Hamilton manufactures a complete range of high performance liquid chromatography (HPLC) syringes and thin layer chromatography (TLC) syringes. HPLC Syringes HPLC syringes

More information

Measurement, Separations, and More. More than 2,000 Syringes and Accessories

Measurement, Separations, and More. More than 2,000 Syringes and Accessories Measurement, Separations, and More More than 2,000 and Accessories TABLE OF CONTENTS Table of Contents... 3 Manual Sample Transfer and Manual HPLC...3-4 Manual GC... 5 HPLC Autosampler... 6 Featured Product:

More information

Syringe Guide. The Measure of Excellence for your application

Syringe Guide. The Measure of Excellence for your application Syringe Guide The Measure of Excellence for your application Unsurpassed Accuracy and Precision Hamilton syringes are the finest quality precision fluid measuring devices available. Top quality materials

More information

cataleg-inl-2007-def6.indd /01/ :27:30

cataleg-inl-2007-def6.indd /01/ :27:30 140 cataleg-inl-2007-def6.indd 140 30/01/2009 17:27:30 Index Syringes Hamilton Syringes Content Page Content Page Hamilton General Information 142 Hamilton Syringes 143-146 700 Series MICROLITER Syringes

More information

Syringe Care and Use Guide. Complete Guide to Maintaining and Using Hamilton Microliter, Gastight and Specialty Syringes

Syringe Care and Use Guide. Complete Guide to Maintaining and Using Hamilton Microliter, Gastight and Specialty Syringes Syringe Care and Use Guide Complete Guide to Maintaining and Using Hamilton Microliter, Gastight and Specialty Syringes TABLE OF CONTENTS Table of Contents Introduction...4 Syringe Use...6 Daily Use Protocol...6

More information

More accurate results.

More accurate results. More choices. More productivity. More accurate results. Agilent's Complete Line of Autosampler and Manual Syringes Specifications and Selection Guide Table of Contents Introduction to Agilent Syringes...2

More information

SYRINGE CARE AND USE. Complete Guide to Maintaining and Using Hamilton GASTIGHT, MICROLITER TM, and Specialty Syringes

SYRINGE CARE AND USE. Complete Guide to Maintaining and Using Hamilton GASTIGHT, MICROLITER TM, and Specialty Syringes SYRINGE CARE AND USE Complete Guide to Maintaining and Using Hamilton GASTIGHT, MICROLITER TM, and Specialty Syringes Table of Contents Introduction 3 Syringe Schematics 4 Syringe Use 5 Daily Use Protocol

More information

Needle Gauge. Needle OD (mm) Needle ID (mm)

Needle Gauge. Needle OD (mm) Needle ID (mm) s LC Manual s Beckman/Altex, Rheodyne, SSI Instruments and Valco Valves s and Borosilicate Glass Barrel Outer Diameter () Scale 5 µl and 10 µl = 6.5 mm, 25 µl to 500 µl = 8 mm, 1 ml = 8.8 mm, 2.5 ml =

More information

AUTOMATED LIQUID HANDLING

AUTOMATED LIQUID HANDLING AUTOMATED LIQUID HANDLING Instrument Syringes R THE MEASURE OF EXCELLENCE TM The Measure of Excellence Automated Instrument Syringes When it comes to precision fluid handling, rely on the leader. We ve

More information

AUTOMATED LIQUID HANDLING

AUTOMATED LIQUID HANDLING AUTOMATED LIQUID HANDLING Instrument Syringes R THE MEASURE OF EXCELLENCE TM The Measure of Excellence Automated Instrument Syringes When it comes to precision fluid handling, rely on the leader. We ve

More information

Gas Chromatography Syringe Selection Guide

Gas Chromatography Syringe Selection Guide Gas Chromatography Syringe Selection Guide Peter Morgan, Fisher, Runcorn, Cheshire, UK Technical Note 20552 Key Words Syringe selection Abstract Choosing the correct syringe from the wide selection available

More information

Thermo Scientific Finnpipette Manual Pipetting Systems. you can handle. anything

Thermo Scientific Finnpipette Manual Pipetting Systems. you can handle. anything Thermo Scientific Manual Pipetting Systems you can handle anything Leader in Pipetting Technology Since the introduction of the first variable volume micropipette in 1971, more than four million Thermo

More information

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer HI 903 Karl Fischer Volumetric Titrator Measures 100 ppm to 100% water content Precision titrant delivery system 40,000 step, piston dosing pump Accurate to 0.1% Delivers as little as 0.125 µl of titrant

More information

injections. Needle Tip 1 µl Cone 1BR

injections. Needle Tip 1 µl Cone 1BR s General Purpose Manual s 0.5-5 µl Nano With the ability to inject down to 50 nl with high precision and accuracy, SGE Nano s are perfect for Nano capillary chromatography injection as well as making

More information

max airless Operating Manual for Dispenser Read this manual thoroughly before operating the Labmax airless!

max airless Operating Manual for Dispenser Read this manual thoroughly before operating the Labmax airless! Operating Manual for max airless Dispenser Read this manual thoroughly before operating the Labmax airless! witeg Labortechnik GmbH Am Bildacker 16 D-97866 Wertheim/Main Phone: +49 (0)9342 / 9301-0 Fax:

More information

The Measure of Excellence. GC Autosampler Syringes. CTC GC PAL Autosampler Syringes (PAL is a registed trademark of CTC Analytics AG, Switzerland)

The Measure of Excellence. GC Autosampler Syringes. CTC GC PAL Autosampler Syringes (PAL is a registed trademark of CTC Analytics AG, Switzerland) The Measure of Excellence GC Autosampler Syringes For manual injection and for automatic injectors (autosamplers) from leading manufacturers you can choose from a wide variety of HAMILTON syringes. CTC

More information

Parts and Consumables. Sciclone ALH 3000 and Zephyr Liquid Handlers

Parts and Consumables. Sciclone ALH 3000 and Zephyr Liquid Handlers Parts and Consumables Sciclone ALH 3000 and Zephyr Liquid Handlers 2006 DISPOSABLE TIPS 3 ARRAYS 7 CONSUMABLE POSITIONING 8 ON-DECK ACCESSORIES 10 TEMPERATURE CONTROLLED LOCATORS 12 WASHING STATIONS 13

More information

Color-coded display window for easy tip selection. Precise, 4-digit volume display with integrated zoom function for optimal readability

Color-coded display window for easy tip selection. Precise, 4-digit volume display with integrated zoom function for optimal readability LIQUID HANDLING LIQUID HANDLING Simple volume adjustment Our premium BOECO GP Series single- and multichannel air-interface adjustable Micropipettes include all features requested by the user: Robustness,

More information

Thermo Scientific Finntip Pipette Tips. HANDHELD PIPETTING Finntip Pipette Tips. Details

Thermo Scientific Finntip Pipette Tips. HANDHELD PIPETTING Finntip Pipette Tips. Details Thermo Scientific Finntip Pipette Tips Finntip* pipette tips are manufactured using high quality materials and the latest molding techniques for proven reliability. Thermo Scientific Finntip pipette tips

More information

HI Total Acidity Mini Titrator for Water Analysis

HI Total Acidity Mini Titrator for Water Analysis HI 84530 Total Acidity Mini Titrator for Water Analysis Piston Driven Pump with Dynamic Dosing The HI 84530 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts the

More information

Advanced in vitro exposure systems VITROCELL VC 10 S-TYPE SMOKING ROBOT

Advanced in vitro exposure systems VITROCELL VC 10 S-TYPE SMOKING ROBOT Advanced in vitro exposure systems VITROCELL VC 10 S-TYPE SMOKING ROBOT Platform concept conventional cigarettes e-cigarettes fast cleaning VITROCELL SMOKING ROBOT VC 10 S-TYPE Features all special requirements

More information

NEW! Thermo Scientific ClipTip Pipetting Systems. sealed in security. feel the difference

NEW! Thermo Scientific ClipTip Pipetting Systems. sealed in security. feel the difference NEW! Thermo Scientific ClipTip Pipetting Systems sealed in security feel the difference Breakthrough ClipTip technology See it in action at: www.fishersci.com/handleanything Achieve newfound confidence

More information

micropipettes clinical laboratory single channel fully autoclavable

micropipettes clinical laboratory single channel fully autoclavable 46 clinical laboratory single channel micropipettes fully autoclavable High precision micro pipettes combine the highest levels of accuracy and precision with design innovations intended to make the pipetting

More information

Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL

Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL Table of Contents Bryan-DUmon Series II rigid bronchoscope 1. 2. 3. 4. 5. Diagram and Overview Universal Barrel Bronchial and

More information

Top Performance. Uncompromising from the bottom to the top Eppendorf Varispenser 2 and Varispenser 2x

Top Performance. Uncompromising from the bottom to the top Eppendorf Varispenser 2 and Varispenser 2x Top Performance Uncompromising from the bottom to the top Eppendorf Varispenser 2 and Varispenser 2x 2 Varispenser 2/2x Eppendorf Varispenser 2 / 2x For laboratory tasks with aliquots of aggressive solutions

More information

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION TABLE OF CONTENTS EDITION 5 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2 - INTRODUCTION 2.1. INTRODUCTION 3 Section 3 - GENERAL 3.1. UNPACKING AND INSTALLATION

More information

autosamplers ASI-100 and ASI-100T Autosamplers

autosamplers ASI-100 and ASI-100T Autosamplers autosamplers ASI-100 and ASI-100T Autosamplers The ASI-100 and ASI-100T Automated Sample Injectors are highly flexible autosamplers for automating high performance liquid chromatography (HPLC) methods.

More information

NEW! Thermo Scientific ClipTip Pipetting Systems. sealed in security. feel the difference

NEW! Thermo Scientific ClipTip Pipetting Systems. sealed in security. feel the difference NEW! Thermo Scientific ClipTip Pipetting Systems sealed in security feel the difference Breakthrough ClipTip technology See it in action at: thermoscientific.com/cliptip Achieve newfound confidence with

More information

Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2

Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2 Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2 Ordering Information You may contact us via phone, fax, e-mail, or through our website. EPOND S.A. CP 389 CH-1800 Vevey Switzerland Phone:

More information

NEW! Thermo Scientific ClipTip Pipetting Systems. sealed in security. feel the difference

NEW! Thermo Scientific ClipTip Pipetting Systems. sealed in security. feel the difference NEW! Thermo Scientific ClipTip Pipetting Systems sealed in security feel the difference Breakthrough ClipTip technology See it in action at: thermoscientific.com/cliptip Achieve newfound confidence with

More information

MEDIUM-FLOW PNEUMOTACH TRANSDUCER

MEDIUM-FLOW PNEUMOTACH TRANSDUCER MEDIUM-FLOW PNEUMOTACH TRANSDUCER SS11LA for MP3x and MP45 System TSD117 & TSD117-MRI for MP150/MP100 System RX117 Replacement Airflow Head See also: AFT series of accessories for airflow and gas analysis

More information

THE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT

THE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT USER MANUAL THE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT 3 QUICK START GUIDE For those familiar with e-cigarettes, the steps below

More information

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual Page 1 / 14 Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual ZV-3051-0200-15 200 Page 2 / 14 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. TEST

More information

ELECTRONIC PIPETTE. The electronic pipette with guaranteed performance in both standard and repetitive pipetting. PRECISE EASY-TO-USE RELIABLE

ELECTRONIC PIPETTE. The electronic pipette with guaranteed performance in both standard and repetitive pipetting. PRECISE EASY-TO-USE RELIABLE ELECTRONIC PIPETTE The electronic pipette with guaranteed performance in both standard and repetitive pipetting. PRECISE EASY-TO-USE RELIABLE DELIVER ON-TARGET PERFORMANCE PIPETMAN M has been designed

More information

FasMate Quick Connectors Industry Applications:

FasMate Quick Connectors Industry Applications: FasMate Quick Connectors Industry Applications: The FasMate Series instantly seals threaded ports from vacuum up to 344.7 bar. The patented proprietary design makes sealing threaded ports as easy as 1,

More information

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis HI 84532 Titratable Acidity Mini Titrator for Fruit Juice Analysis Piston Driven Pump with Dynamic Dosing The HI 84532 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts

More information

BROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / VACUUM

BROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / VACUUM BROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / ACUUM LAB TABLE OF CONTENTS Content Page Table of Content 2 Product Overview 3 BROEN UniFlex TM BASIC 4-5 Fittings for Non-burnig 2.0 Gases/acuum Turret

More information

PEEK SS Columns & Guard Columns

PEEK SS Columns & Guard Columns PEEK SS Columns & Guard Columns ~ Stainless Steel Analytical Columns ~ PEEK Columns ID 2.1, 4.0, 4.6 & 7.5 mm ~ Jour-Guard Cartridges Stainless Steel or PEEK ~ Stainless Steel End Fittings 1/4 OD Columns

More information

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis

HI Titratable Acidity Mini Titrator for Fruit Juice Analysis HI 84532 Titratable Acidity Mini Titrator for Fruit Juice Analysis Piston Driven Pump with Dynamic Dosing The HI 84532 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts

More information

SURETEST Torque Calibration System

SURETEST Torque Calibration System SURETEST TM The SURETEST is a laboratory grade instrument which captures torque measurements with a user friendly interface. It features a large LCD graphical display. It may be used with a single transducer

More information

TJF-160F/VF Cleaning and Disinfection Checklist

TJF-160F/VF Cleaning and Disinfection Checklist TJF-160F/VF Cleaning and Disinfection Checklist TJF-160F/VF Cleaning and Disinfection Checklist This checklist is used to evaluate and confirm if cleaning and disinfection of the TJF-160F/VF has been performed

More information

Choose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide

Choose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide Choose for Your Instrument GC Supplies - Shimadzu Instrument Quick Pick Guide Syringes Septa Inlet Liners O-rings and Sealing Rings SilTite FingerTite Ferrules Ferrules Replacement Parts Your chromatography

More information

Rev 1.0. CMA 470 Refrigerated Fraction Collector

Rev 1.0. CMA 470 Refrigerated Fraction Collector 8002778 Rev 1.0 CMA 470 Refrigerated Fraction Collector CMA 470 REFRIGERATED FRACTION COLLECTOR USER S MANUAL CONTENTS 1 INTRODUCTION... 3 2 SAFETY... 3 3 UNPACKING & ASSEMBLY... 4 3.1 Packing list...

More information

Innovations in Administration and Injection Systems EXPERIENCED CREATIVE FOCUSED

Innovations in Administration and Injection Systems EXPERIENCED CREATIVE FOCUSED Innovations in Administration and Injection Systems EXPERIENCED CREATIVE FOCUSED Meeting Your Drug Administration Challenges Your injectable drug product will be perfectly pure when you ship it, but will

More information

Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE

Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE Options for e-cigarettes VITROCELL VC 1 SMOKING MACHINE Manual smoking machine with high tech features square puff profiles higher puff

More information

Product Catalog 2016 EMEA

Product Catalog 2016 EMEA Product Catalog EMEA 2016 PORTFOLIO SOL-M Standard medical devices SOL-GUARD Basic safety medical devices SOL-CARE Innovative and advanced safety-engineered medical devices Sol-Millennium Europe Sp. z

More information

HI Total Alkalinity Mini Titrator for Water Analysis

HI Total Alkalinity Mini Titrator for Water Analysis HI 84531 Total Alkalinity Mini Titrator for Water Analysis Piston Driven Pump with Dynamic Dosing The HI 84531 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts the

More information

THYROID UPTAKE SYSTEMS

THYROID UPTAKE SYSTEMS 76 CAPTUS 4000e THYROID UPTAKE SYSTEM New and improved stand provides ergonomically adjustable monitor and easy to position articulating collimator arm. Four sided comfortable handle grips and swivel wheels

More information

STANDARD SAMPLE INTRODUCTION

STANDARD SAMPLE INTRODUCTION STANDARD SAMPLE INTRODUCTION PFA and Polypropylene High-Efficiency MicroFlow Nebulizers MicroFlow nebulizers are resistant to clogging, are reliably self-aspirated or pumped and produce a fi ne aerosol

More information

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide LeadCare II BLOOD LEAD ANALYZER Quick Reference Guide Precautions Precautions Caution The LeadCare II Blood Lead Analyzer is a CLIA-waived device. Facilities that perform tests with the LeadCare II System

More information

SURETEST Torque Calibration System

SURETEST Torque Calibration System SURETEST Torque SURETEST TM The SURETEST is a laboratory grade instrument which captures torque measurements with a user friendly interface. It features a large LCD graphical display. It may be used with

More information

Advanced in vitro exposure systems

Advanced in vitro exposure systems Advanced in vitro exposure systems VITROCELL VC 1/7 SMOKING MACHINE Features for e-cigarettes VITROCELL VC 1/7 SMOKING MACHINE Linear smoking machine with high tech features square puff profiles higher

More information

HI Total Alkalinity Mini Titrator for Water Analysis

HI Total Alkalinity Mini Titrator for Water Analysis HI 84531 Total Alkalinity Mini Titrator for Water Analysis Piston Driven Pump with Dynamic Dosing The HI 84531 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts the

More information

25-Hydroxyvitamin D2-D3 Serum LC-MS/MS APCI Analysis Kit User Manual

25-Hydroxyvitamin D2-D3 Serum LC-MS/MS APCI Analysis Kit User Manual Page 1 / 15 25-Hydroxyvitamin D2-D3 Serum LC-MS/MS APCI Analysis Kit User Manual ZV-3046-0200-10 200 Page 2 / 15 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. IVD SYMBOLS...

More information

Cigarette Smoking Machine CSM-SCSM. User s Manual

Cigarette Smoking Machine CSM-SCSM. User s Manual Cigarette Smoking Machine CSM-SCSM User s Manual CH TECHNOLOGIES (USA), Inc. Copyright 2011 CONTENTS 1. Introduction... 3 2. CSM-SCSM Description... 3 3. CSM-SCSM Specifications...6 4. Preparation of CSM-SCSM

More information

Low Row. User manual E S S E N T I A L S T R E N G T H

Low Row. User manual E S S E N T I A L S T R E N G T H E L E M E N T E S S E N T I A L S T R E N G T H User manual 1 The identification plate of and manufacturer, affixed on the back panel of the weight stack, gives the following details: A B C D E Name and

More information

Savillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES

Savillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES Savillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES Summary The Savillex C-Flow 700d (C700d) is a concentric PFA nebulizer designed specifically for ICP-OES, combining extreme matrix

More information

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I

PORTO 2 VENT CPAP OS. Operator s Manual. PORTO 2VENT CPAP OS System Operator s Manual Part Number Rev I PORTO 2 VENT CPAP OS Operator s Manual 1 2 TABLE of CONTENTS 1. Introduction 3. Operating Instructions 1a. Definitions 3a. Setting the CPAP Level 1b. General Description 3b. Applying the Breathing Circuit

More information

Quick Sealing with a Twist to Connect Actuation Method

Quick Sealing with a Twist to Connect Actuation Method - Finger tighten seals up to 689 bar (10,000 psi) for pneumatic and hydraulic testing - Safe and Reliable leak tight connections to male and female threads - Eliminate thread damage, sealant and wrenches

More information

Instruction Manual Aerogen, Inc. Part No. AG-AL1010 Rev. C

Instruction Manual Aerogen, Inc. Part No. AG-AL1010 Rev. C Instruction Manual 2004 Aerogen, Inc. Part No. AG-AL1010 Rev. C Table of Contents Introduction... 3 System description... 4 Warnings... 5 Cautions... 5 Electromagnetic Susceptibility... 5 Symbols... 6

More information

Eppendorf Research plus. Raise the limits NEW! Order no. A /GB4/10T/1109/FEEL/PRINT64 Printed in Germany

Eppendorf Research plus. Raise the limits NEW!  Order no. A /GB4/10T/1109/FEEL/PRINT64 Printed in Germany www.eppendorf.com/research-plus Your local distributor: www.eppendorf.com/worldwide Eppendorf AG 22331 Hamburg Germany Tel: +49 40 538 01-0 Fax: +49 40 538 01-556 E-mail: eppendorf@eppendorf.com Eppendorf

More information

Raise the limits. Eppendorf Research plus

Raise the limits. Eppendorf Research plus NEW! NEW! Raise the limits Eppendorf Research plus A completely new experience Eppendorf Research plus Eppendorf sets a new standard in pipetting. The ultra light Eppendorf Research plus pipette meets

More information

Thermo Scientific ClipTip Pipetting Systems. Sealed in security Feel the difference

Thermo Scientific ClipTip Pipetting Systems. Sealed in security Feel the difference Thermo Scientific ClipTip Pipetting Systems Sealed in security Feel the difference Breakthrough ClipTip technology Achieve newfound confidence with the Thermo Scientific ClipTip pipetting system that lock

More information

888/890 Enter the Titrando world

888/890 Enter the Titrando world 888/890 Enter the Titrando world 2 888 Titrando potentiometric titrator 890 Titrando Karl Fischer titrator Touch Control with large color screen Titration software PC Control or tiamo TM for operation

More information

Patient Information Publications Warren Grant Magnuson Clinical Center National Institutes of Health

Patient Information Publications Warren Grant Magnuson Clinical Center National Institutes of Health Warren Grant Magnuson Clinical Center National Institutes of Health What is a subcutaneous injection? A subcutaneous injection is given in the fatty layer of tissue just under the skin. A subcutaneous

More information

CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED ARC 5 ELECTRONIC CIGARETTE KIT.

CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED ARC 5 ELECTRONIC CIGARETTE KIT. USER MANUAL YOUR ARC 5 BATTERY CS AIR SLIM TANK Tank connection Mouthpiece CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED ARC 5 ELECTRONIC CIGARETTE KIT. UP adjustment button DOWN adjustment button

More information

NEW! Thermo Scientific ClipTip Pipetting Systems. sealed in security. feel the difference

NEW! Thermo Scientific ClipTip Pipetting Systems. sealed in security. feel the difference NEW! Thermo Scientific ClipTip Pipetting Systems sealed in security feel the difference Breakthrough ClipTip technology See it in action at: thermoscientific.com/cliptip Achieve newfound confidence with

More information

Agilent 1220 Infinity LC System Performance Specifications

Agilent 1220 Infinity LC System Performance Specifications IET International Equipment Trading, Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 1220 Infinity LC System Performance

More information

QuickSplitTM Flow Splitters

QuickSplitTM Flow Splitters QuickTM Flow ters between 2 or more detectors such as Mass Spectroscopy and evaporative light scattering, UV, or IR. This is especially important when one of the detectors is destructive, such as Mass

More information

INTEGRAL-BONNET NEEDLE VALVES H-300 SERIES

INTEGRAL-BONNET NEEDLE VALVES H-300 SERIES INTEGRAL-BONNET NEEDLE VALVES SERIES INTEGRAL-BONNET NEEDLE VALVES SERIES FEATURES n Straight and angle pattern n Stainless Steel and Brass construction n MAWP 5000 psi (345 bar) n MAWT 446 F (230 C) n

More information

Helping to protect you from exposure to hazardous drugs

Helping to protect you from exposure to hazardous drugs Helping to protect you from exposure to hazardous drugs Closed system solution: Texium closed male luer and SmartSite needle-free valve products What you can t see can hurt you The risks are well documented

More information

Pipet Tips. Overview Tip Refill System Microvolume Tips Universal Fit Aerosol Barrier Tips Multi-Barrier Tips...

Pipet Tips. Overview Tip Refill System Microvolume Tips Universal Fit Aerosol Barrier Tips Multi-Barrier Tips... Pipet Tips Overview... 74 Tip Refill System... 76 Microvolume Tips... 77 Universal Fit... 68 Aerosol Barrier Tips... 80 Multi-Barrier Tips... 82 Axypet-16 384-Format Tips... 83 Macrovolume Tips... 83 Gel

More information

Ordering Information You may contact us via phone, fax, , or through our website.

Ordering Information You may contact us via phone, fax,  , or through our website. Elemental Scientific (ESI) designs and produces a range of sample introduction systems for the determination of trace element concentrations and isotope ratios in liquid samples when using inductively

More information

Eppendorf SOP. Standard Operating Procedure for Pipettes. Register your instrument!

Eppendorf SOP. Standard Operating Procedure for Pipettes. Register your instrument! rating Procedure for Pipettes EN) Operating P Procedure for Pipettes Register your instrument! www.eppendorf.com/myeppendorf Standard Operating Procedure for Pipettes Copyright 2014 Eppendorf AG, Hamburg.

More information

Total Acid Number in petroleum products by automatic titration

Total Acid Number in petroleum products by automatic titration APPLICATION NOTE Total Acid Number in petroleum products by automatic titration No. T3 Water Analysis Instruments, Thermo Fisher Scientific Key words TAN, ASTM D664, ISO 6619, oil, used oil, lubricant,

More information

Ordering Information You may contact us via phone, fax, , or through our website.

Ordering Information You may contact us via phone, fax,  , or through our website. (ESI) designs and produces a range of sample introduction systems for the determination of trace element concentrations and isotope ratios in liquid samples when using inductively coupled plasma instrumentation

More information

Calibration Standards

Calibration Standards Calibration Standards/ Calibration Standards TSKgel standards polystyrene TSKgel standards poly(ethylene oxide) PStQuick polystyrene calibration standards TSKgel guard column products Fittings Pre-injector

More information

Shimadzu s Guide to Vial Selection. Not all vials are the same

Shimadzu s Guide to Vial Selection. Not all vials are the same Shimadzu s Guide to Vial Selection Not all vials are the same The perfect vial? Struggling to find the right vial or microtiter plate? You are not alone! What material? Are all vials the same? The Perfect

More information

COST, PROCESS & QUALITY IMPROVEMENT

COST, PROCESS & QUALITY IMPROVEMENT COST, PROCESS & QUALITY IMPROVEMENT - Finger tighten seals up to 10,000 psi (689 bar) for pneumatic and hydraulic testing - Safe and Reliable leak tight connections to male and female threads - Eliminate

More information

NEW: with integrated step counter. Count on it! The new Eppendorf Multipette M4: simple, stress-free and ergonomic

NEW: with integrated step counter. Count on it! The new Eppendorf Multipette M4: simple, stress-free and ergonomic NEW: with integrated step counter Count on it! The new Eppendorf Multipette M4: simple, stress-free and ergonomic 2 Eppendorf Multipette M4 Serial pipetting made easy The Multipette M4 makes performing

More information

SIMPLICITY - PERFORMANCE - EXCELLENCE. Equipment for implantology and surgery

SIMPLICITY - PERFORMANCE - EXCELLENCE. Equipment for implantology and surgery SIMPLICITY - PERFORMANCE - EXCELLENCE Equipment for implantology and surgery Table of Contents Equipment for implantology and surgery P. 4 IMPLANTEO a Implantology and surgery motor P. 6 MONT BLANC RANGE

More information

Medescan Nebuliser Med - S600A Instructions Manual

Medescan Nebuliser Med - S600A Instructions Manual Medescan Nebuliser Med - S600A Instructions Manual Please read this guidebook carefully before operating this unit Your Nebuliser is intended for use in the treatment of asthma, COPD and other respiratory

More information

Signet 2850 Conductivity/Resistivity Sensor Electronics

Signet 2850 Conductivity/Resistivity Sensor Electronics Signet 850 Conductivity/Resistivity Sensor Electronics -850.090- -850.090- Rev. C 08/07 English ENGLISH SAFETY INSTRUCTIONS. Depressurize and vent system prior to installation or removal.. Confi rm chemical

More information

FINE INSTRUMENTS AND EQUIPMENT FOR LIPOPLASTY

FINE INSTRUMENTS AND EQUIPMENT FOR LIPOPLASTY FINE INSTRUMENTS AND EQUIPMENT FOR LIPOPLASTY Handles & Hubs Vitruvian Handle 20% lighter than a standard handle Thumb imprint for comfort Easy tubing connection Ribbed surface for excellent grip and control

More information

Exactly what you re looking for. High Quality Instruments for Vitreoretinal Surgery

Exactly what you re looking for. High Quality Instruments for Vitreoretinal Surgery Exactly what you re looking for High Quality Instruments for Vitreoretinal Surgery Exactly what you re For over a decade, MedOne has been helping retina surgeons around the world conquer complex surgical

More information

Savillex Technical Note

Savillex Technical Note Savillex Technical Note C700d PFA Concentric Nebulizer for ICP-OES Summary The Savillex C-Flow 700d (C700d) is a concentric PFA nebulizer designed specifically for ICP-OES, combining extreme matrix tolerance

More information

HEINE Otoscopes. Page 007 / / GENERAL MEDICINE AND ENT INSTRUMENTS OTOSCOPES [ 006 ] 01. K 180 F.O. mini 3000 F.O.

HEINE Otoscopes. Page 007 / / GENERAL MEDICINE AND ENT INSTRUMENTS OTOSCOPES [ 006 ] 01. K 180 F.O. mini 3000 F.O. [ 006 ] 01 OTOSCOPES HEINE Otoscopes BETA 400 F.O. BETA 200 F.O. K 180 F.O. mini 3000 F.O. BETA 100 K 100 mini 3000 Housing construction Metal Polycarbonate Viewing window Glass Acrylic 3 x magnification

More information

Simple. Stress-free. The Newtron Ultrasonics Series

Simple. Stress-free. The Newtron Ultrasonics Series Simple. Stress-free. The Newtron Ultrasonics Series 1 3 YEARS OF EXPERTISE FOR YOUR SAFETY. Our researchers and developers blazed new trails with the invention of piezoelectric ultrasonic technology in

More information

Lateral Flow Reagent Dispenser Instruction Manual

Lateral Flow Reagent Dispenser Instruction Manual Lateral Flow Reagent Dispenser Instruction Manual 1182 Monte Vista Ave. Suite #11 Claremont, CA 91786 0 Phone: 909-920-3887 Fax: 909-946-1132 Specifications Dimensions (L x W x H): 457 x 146 x 75 mm (excluding

More information

ASPIJECT. ASPIJECT Active. ASPIJECT Safe PAROJECT INJECTION

ASPIJECT. ASPIJECT Active. ASPIJECT Safe PAROJECT INJECTION DENTAL INNOVATIONS INJECTION ASPIJECT ASPIJECT Safe ASPIJECT Active PAROJECT Injection syringe for infiltration and block anaesthesia. For automatic (passive) aspiration. Its unique design offers the ultimate

More information

INSTRUCTIONS FOR USE

INSTRUCTIONS FOR USE Comfort Injects 50 Comfort-in INSTRUCTIONS FOR USE English user manual 1 Introduction Thank you for choosing the Comfort in Needle free Injection system, developed with your comfort and convenience in

More information

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial

Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial Instructions for Use Enbrel (en-brel) (etanercept) for injection, for subcutaneous use Multiple-dose Vial How do I prepare and give an injection with Enbrel multiple-dose vial? A multiple-dose vial contains

More information

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems

Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems Signet 2850 Conductivity/Resistivity Sensor Electronics and Integral Systems Features Certificate of calibration supplied with all sensors. Universal Mount Custom cell constant programmed into the electronics.

More information

Linear Array Transducer

Linear Array Transducer User Guide Type 8809 Linear Array Transducer English BB 0911-H August 2012 For Professional Users Only WORLD HEADQUARTERS Mileparken 34 DK-2730 Herlev Denmark Tel.:+45 44528100 / Fax:+45 44528199 www.bkmed.com

More information

RUBBER WATERBLAST HOSES

RUBBER WATERBLAST HOSES up to 15, PSI (1 Bar) RUBBER WATERBLAST HOSES These high pressure hose assemblies combine rugged construction, dependability and safe performance. Designed specifically for waterblast applications Lightweight

More information

OTAGO LIPOSURG. Compact, powerful system for infiltration and liposuction

OTAGO LIPOSURG. Compact, powerful system for infiltration and liposuction OTAGO LIPOSURG Compact, powerful system for infiltration and liposuction The Otago LipoSurg is the first medical device which allows infiltration and Liposuction in a single compact device. FEATURES AND

More information

Mouse C-Peptide ELISA Kit

Mouse C-Peptide ELISA Kit Mouse C-Peptide ELISA Kit Cat.No: DEIA4507 Lot. No. (See product label) Size 96T Intended Use The Mouse C-Peptide ELISA kit is for the quantitative determination of c-peptide in mouse serum, plasma, and

More information

Restek PAL SPME Fibers cat.#

Restek PAL SPME Fibers cat.# 1 Restek PAL SPME Fibers cat.# 27478 27483 Solid phase microextraction (SPME) fibers are used to extract organic compounds from solid, liquid, and vapor matrices onto a stationary phase that is bonded

More information