Technical Bulletin. Technical Information for Quidel Molecular Influenza A+B Assay on the Bio-Rad CFX96 Touch

Similar documents
Technical Bulletin. Technical Information for Lyra Direct Strep Assay

From M100en v2014aug06 Page 1 of 35

Allergy Basics. This handout describes the process for adding and removing allergies from a patient s chart.

INTERPRETATION OF RESULTS USING THE LIFE TECHNOLOGIES QUANTSTUDIO DX REAL-TIME PCR INSTRUMENT... 14

TMWSuite. DAT Interactive interface

Clinical Essentials Test Blueprint

QUICK REFERENCE INSTRUCTIONS For use with Sofia and Sofia 2. Rx only

Sleep Apnea Therapy Software Clinician Manual

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

Sleep Apnea Therapy Software User Manual

Anticoagulation Manager - Getting Started

HIV-1 Viral Load Real Time (RG)

DENTRIX ENTERPRISE 8.0.5

User Instruction Guide

QUICK REFERENCE INSTRUCTIONS For use with Sofia only.

Quick guide for 3shape order form

BlueBayCT - Warfarin User Guide

QUICK REFERENCE INSTRUCTIONS

AudioConsole. User Guide. Doc. No EN/01 Part No EN

Sanako Lab 100 STS USER GUIDE

SANAKO Lab 100 STS USER GUIDE

HBV Real-TM Quant Handbook

HIV DNA Qual FRT Real Time Kit

PBSI-EHR Off the Charts!

Entering HIV Testing Data into EvaluationWeb

ShoreTel Trunk Side Integration Guide

Instructions for Use. RealStar Influenza Screen & Type RT-PCR Kit /2017 EN

altona RealStar Instructions for Use RealStar CMV PCR Kit /2017 EN DIAGNOSTICS

Appendix B. Nodulus Observer XT Instructional Guide. 1. Setting up your project p. 2. a. Observation p. 2. b. Subjects, behaviors and coding p.

Lionbridge Connector for Hybris. User Guide

MODULE: SQUAT JUMP BRIEF DESCRIPTION:

Making a Room Reservation with Service Requests in Virtual EMS

OneTouch Reveal Web Application. User Manual for Healthcare Professionals Instructions for Use

[HEALTH MAINTENANCE AND INVITATIONS/REMINDERS] June 2, 2014

Diabetes Management Software V1.3 USER S MANUAL

About REACH: Machine Captioning for Video

Proteome Discoverer Version 1.3

How to enter and update Immunizations using HF71

Creating YouTube Captioning

Step-by-Step RECD Guide

RaySafe i3 INSTALLATION & SERVICE MANUAL

INSTRUCTOR WALKTHROUGH

(DNA) Real-time PCR. Exicycler 96 Rotor-Gene Q/6000 PCR

This document presents the reader with instructions on using AudBase in the UCSF environment. AudBase Guidebook. Application How-To.

Available for CEREC SW, inlab CAD SW, 3Shape, Dental Wings, DWOS Lava Edition, exocad, Open design software. Atlantis. Atlantis Core File.

Storage: Logix Smart Zika Virus Master Mix and Logix Smart Zika Virus Positive Control must be stored at -20 ⁰C and can last up to 60 days.

Managing and Taking Notes

Using SPSS for Correlation

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

Dementia Direct Enhanced Service

Module 3: Pathway and Drug Development

Instructions for Use. RealStar Influenza S&T RT-PCR Kit /2017 EN

HOW TO USE THE BENCHMARK CALENDAR SYSTEM

General Single Ion Calibration. Pete 14-May-09

Corporate Online. Using Term Deposits

Managing and Taking Notes

RESULTS REPORTING MANUAL. Hospital Births Newborn Screening Program June 2016

Software Version 2.0. User s Guide

RealLine HCV Qualitative Str-Format

Welcome to CareLink Pro

Provider Dashboard User's Manual

MEAT CONTENT CALCULATION

Content Part 2 Users manual... 4

Chapter 8: ICD-10 Enhancements in Avalon

Care Pathways User Guide

Specimen. Humeral Head. Femoral Head. Objective. Femoral Condyle (medial) Supplementary Figure 1

Warfarin Help Documentation

Nodule Detection process: 1. Click on the patient study to be loaded 2. Click the drop down arrow next to the analysis button and select LNA

OneTouch Reveal Web Application. User Manual for Patients Instructions for Use

(DNA) Real-time PCR. Exicycler 96 Rotor-Gene Q/6000 PCR

Diabetes Management App. Instruction Manual

RealLine HIV quantitative Str-Format

Cloud Condensation Nuclei Counter (CCN) Module

GlucoManager TM. Pro Software. User s Guide

The Hospital Anxiety and Depression Scale Guidance and Information

Titrations in Cytobank

Using the CFS Infrastructure

Medtech32 Diabetes Get Checked II Advanced Form Release Notes

iworx Sample Lab Experiment AN-5: Cockroach Leg Mechanoreceptors

Chronic Pain Management Workflow Getting Started: Wrenching In Assessments into Favorites (do once!)

GE Healthcare Life Sciences. Methodology Guideline AA. Quantification of influenza hemagglutinin using Biacore T200

Amplifon Hearing Health Care

Avian Influenza A H5N8

Documenting Patient Immunization. New Brunswick 2018/19

Data Management System (DMS) User Guide

Registration Instructions Thank you for joining the Million Mile Movement!

1. Automatically create Flu Shot encounters in AHLTA in 2 mouse clicks. 2. Ensure accurate DX and CPT codes used for every encounter, every time.

Unit 1: Introduction to the Operating System, Computer Systems, and Networks 1.1 Define terminology Prepare a list of terms with definitions

Simple Caption Editor User Guide. May, 2017

To open a CMA file > Download and Save file Start CMA Open file from within CMA

ShadeVision v Color Map

MNSCREEN TRAINING MANUAL Hospital Births Newborn Screening Program October 2015

Graphical User Interface for Windows for MCM Module

User Guide for Classification of Diabetes: A search tool for identifying miscoded, misclassified or misdiagnosed patients

ESC-100 Introduction to Engineering Fall 2013

Global reporting system for hepatitis (GRSH) data approval manual

Cerner COMPASS ICD-10 Transition Guide

hmhco.com National GO Math! K 6 USER GUIDE Personal Math Trainer Powered by Knewton

Getting Started.

Transcription:

Technical Bulletin Technical Information for Quidel Molecular Influenza A+B Assay on the Bio-Rad CFX96 Touch Quidel Corporation has verified the performance of the Quidel Molecular Influenza A+B Assay on the Bio-Rad CFX96 Touch, software version 3.0. Internal studies performed by Quidel have demonstrated performance on this instrument is substantially equivalent to analytical and clinical performance data found in the package insert. Due to variations in thermocyclers there are different settings and additional programming procedures that should be followed for the CFX96 Touch software 3.0. These procedures are detailed on pages 2-5. For technical support on the Quidel Molecular Influenza A+B Assay, please call 1+ (800) 874-1517 or (858) 552 1100 (outside the U.S.), Monday through Friday, between 8:00 a.m. and 5:00 p.m., Eastern Time. For e mail support contact technicalsupport@quidel.com You may also visit our website at quidel.com for this or any other Quidel product. Page 1 of 6

Influenza A+B Assay Supplemental Instructions: Creating a CFX96 Touch Influenza A+B Assay Protocol Template Purpose: The following supplemental instructions will aid in programming an assay template for CFX96 Touch from Bio-Rad to run the Quidel Molecular Influenza A+B Assay kit. Seek specific training or guidance if you are unfamiliar with the use of this platform. For assistance with this protocol, please contact Quidel Technical Support directly. Limitations: The following protocol was developed for use with Quidel Molecular Influenza A+B kit specifically. Its suitability for other assays is unknown. Check with Bio-Rad to ensure software compatibility. Programming Instructions: 1. Launch the CFX96 Touch software package 2. In the Startup Wizard pop-up window Select instrument to be CFX96 from the drop down menu 3. Under Select Run Type press the User-defined button 4. Create a new thermocycler protocol by selecting Create New from the Run Setup window 5. Make the following changes to the cycling conditions in the Protocol Editor: Change the Sample Volume to 20 µl a. Under Tools in the top left toolbar select Run Time Calculator and check 96 Wells-All Channels b. Step 1 (Hold) i. Reps: 1 ii. Temp: 55 C iii. Time: 5:00 c. Step 2 (Hold) i. Reps: 1 ii. Temp: 60 C iii. Time: 5:00 d. Step 3 (Hold) i. Reps: 1 ii. Temp: 65 C iii. Time: 5:00 iv. Remove the plate read from this stage by selecting the Remove Plate Read button on the lower left e. Step 4 (2-Step Amplification Stage) i. Highlight step 3 and go to the lower left of the window and select Insert Step for a total of 2 times until step 5 is reached (ensure in the upper left of the window the drop-down menu for Insert Step has After selected). ii. Highlight step 4 and set as follows: 1. Temp: 92 C 2. Time: 0:05 iii. Highlight step 5 and set as follows: Page 2 of 6

1. Temp: 57 C 2. Time: 0:40 3. Go to the left of the screen and select Remove Plate Read button iv. Select step 6, the GOTO step, and change to state GOTO step 4 and change the times to repeat to 9 f. Step 7 (2-Step Amplification Stage) i. With step 6 highlighted select Insert Step button, on the lower left of the window, for a total of 2 times (until step 8 is reached) ii. Highlight step 7 and set as follows: 1. Temp: 92 C 2. Time: 0:05 iii. Highlight step 8 and set as follows: 1. Temp: 57 C 2. Time: 0:40 3. In the left of the window select Add Plate Read to Step button 4. Highlight step 8 and select Insert GOTO button on the lower left of the window iv. Select step 9, the GOTO step, and change to GOTO step 7 and times to repeat to 34 g. Save the new cycling conditions as protocol for future use i. At the upper left of the screen select the Save button ii. Save in the ExpressLoad folder iii. Name the file Quidel Molecular Influenza A+B iv. Save as type Protocol File (*.prcl) v. Select Save vi. Click Ok in the protocol editor window 6. Define the plate setup a. In the Run Setup window select the Plate tab b. Under Express Load in the drop-down menu select Quick Plate 96 wells All Channels.pltd c. Select the Edit Selected button to customize the plate setup d. In the upper toolbar select Settings. The default settings need to be set. i. Plate Size select 96 Wells ii. Plate Type select BR Clear iii. Number Convention select Scientific Notation iv. Units select Copy Number e. Leave the Scan Mode set to All Channels at the top of the window f. Select the Select Fluorophores button on the upper right of the Plate Editor window i. De-select all default fluorophores ii. Select FAM, HEX, and Cy5 and click Ok g. In the Plate Editor window highlight the whole plate and click the check box in front of all fluorophores: FAM, HEX, and Cy5 h. Select the Experiment Settings button in order to define the Targets i. In the lower left of the Experiment Settings window in the New box type in Influenza A and select Add ii. Repeat this for Influenza B and the PRC iii. Select Ok i. In the Plate Editor window next to FAM in the drop-down menu under Target Name select Influenza A, for HEX select Influenza B, and for Cy5 select PRC j. Save the new plate setup for future use i. At the upper left of the screen select the Save button ii. Save in the ExpressLoad folder Page 3 of 6

iii. Name the file Quidel Molecular Influenza A+B plate iv. Save as type Plate File (*.pltd) v. Select Save vi. Click Ok in the Plate Editor window k. Exit the software Page 4 of 6

Influenza A+B Assay Supplemental Instructions: Analyzing a CFX96 Touch Influenza A+B Assay Run Purpose: The following supplemental instructions will aid in analyzing a Quidel Molecular Influenza A+B Assay run on the CFX96 Touch from Bio-Rad. Seek specific training or guidance if you are unfamiliar with the use of this platform. For assistance with this analysis, please contact Quidel Technical Support directly. Limitations: The following analysis was developed for use with Quidel Molecular Influenza A+B kit specifically. Its suitability for other assays is unknown. Check with Bio-Rad to ensure software compatibility. Analysis Instructions: 1. Open the run file that needs to be analyzed 2. In the upper left select the Quantification Tab 3. On the Amplification curve check the box in front of Log Scale 4. Select Settings in the toolbar in the upper left of the screen a. For the Cq Determination Mode select Single Threshold b. Under the Baseline Setting choose Baseline Subtracted Curve Fit c. For Analysis Mode select Target d. Under Cycles to Analyze choose 1-35 and then click Ok e. The baseline cycles and the threshold for each target need to be set i. Ensure that only the Influenza A box is checked in the amplification plot ii. Go up to Settings in the toolbar and select Baseline Threshold 1. At the top of the box select Auto Calculated for the Baseline Cycles 2. For the Single Threshold at the bottom of the box select User Defined a. Set this to 164 b. Select Ok iii. Uncheck the Influenza A box and check the Influenza B box in the amplification plot iv. Go up to Settings in the toolbar and select Baseline Threshold 1. At the top of the box select Auto Calculated for the Baseline Cycles 2. For the Single Threshold at the bottom of the box select User Defined a. Set this to 100 b. Select Ok v. Uncheck the Influenza B box and check the PRC box in the amplification plot vi. Go up to Settings in the toolbar and select Baseline Threshold 1. At the top of the box select Auto Calculated for the Baseline Cycles 2. For the Single Threshold at the bottom of the box select User Defined a. Set this to 100 b. Select Ok 5. Exit the software Page 5 of 6

Interpretation of the Quidel Molecular Influenza A+B Assay Results on the CFX96 Touch Assay Result Detector: Influenza A Detector: Influenza B Detector: Process Control Interpretation of Results Negative Cq < 5.0 or Cq > 35.0 Cq < 5.0 or Cq > 35.0 5.0 Cq 35.0 No Influenza A or Influenza B viral RNA detected; PRC Detected Influenza A Positive 5.0 Cq 35.0 Cq<5.0 or Cq>35.0 NA* Influenza A viral RNA detected Influenza B Positive Cq < 5.0 or Cq > 35.0 5.0 Cq 35.0 NA* Influenza B viral RNA detected Influenza A and B Positive 5.0 Cq 35.0 5.0 Cq 35.0 NA* Influenza A and Influenza B viral RNA detected Invalid Cq < 5.0 or Cq > 35.0 Cq < 5.0 or Cq > 35.0 Cq < 5.0 or Cq > 35.0 No Influenza A or Influenza B viral RNA and no PRC detected; invalid test. Retest the same purified sample. If the test is also invalid, re extract and retest another aliquot of the same sample or obtain a new sample and retest. *No Cq value is required for the Process Control to make a positive call. 0738ID0713I (07/13) Page 6 of 6