VNS Therapy System Physician s Manual

Similar documents
MRI Guidelines for the Axonics Sacral Neuromodulation System

MRI Guidelines for VNS Therapy

MRI GUIDELINES FOR INSPIRE THERAPY

Algovita. MRI Procedure Guidelines. Spinal Cord Stimulation System. 201x

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)

Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System.

Micra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR)

MRI GUIDELINES FOR INSPIRE THERAPY

VNS Therapy System Glossary September 2018

Warning: Patients should not be exposed to MRI environments until the surgical site following pump implantation is fully healed.

The VNS Therapy Magnet

2014 AAPM 56 th Annual Meeting

Advisa MRI and Ensura MRI SureScan pacing systems

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

ImageReady MRI Head Only Guidelines for Spectra WaveWriter Spinal Cord Stimulator System

Phase 1: Output Current

ImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System

AspireSR. Essential information about your new device

MRI guidelines for Medtronic neurostimulation systems for chronic pain

Low-Profile Wrist Fixator. For stabilization of fractures of the distal radius.

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Knee Implants

MRI for Patients with MRI-Conditional Pacing System: Radiographers Role. Lawrance Yip DM, DR, QMH

MRI Procedure Information. For St. Jude Medical MR Conditional Neurostimulation Systems. Clinician's Manual

MRI Procedure Information. For St. Jude Medical MR Conditional Neurostimulation Systems. Clinician's Manual

Medium External Fixator Pediatric Femoral Shaft Frame. Using medium multi-pin clamps.

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Shoulder Implants

Cochlear Implants. Medical Procedures. for MED EL CI Systems. AW33290_5.0 (English US)

Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker

WallFlex Biliary RX Partially Covered Stent System Prescriptive Information

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

Medium External Fixator Humeral Shaft Frame. Modular frame for upper extremity use.

MRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System

Cochlear Implants. Medical Procedures. for MED EL Implant Systems. AW33290_2.0 (English US)

External Distal Radius Fixator. Supplement to the 8 mm rod fixator system

Safety Issue of Static Magnetic Field (1)

An Introduction to VNS Therapy

VNS Therapy Guide. For children and those with special needs with drug-resistant epilepsy

FastFrame External Fixation System. Damage Control Surgical Technique

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Hip Implants

REFILL KIT For use with Prometra Programmable Infusion Systems

Sterile-Packaged Large External Fixator Kits. For treatment of long bone and pelvic fractures that require external fixation.

Large External Fixator Modular Knee Bridge. Using multi-pin clamps.

MRI Safety Information for the HiRes Ultra 3D Cochlear Implant

MRI imaging for patients with cardiac implantable electronic devices (CIEDs)

STANDARD OPERATING PROCEDURE (SOP)

An Introduction to VNS Therapy

Yasargil Permanent Aneurysm Clips

Version überholt. Nicht verwenden. Version obsolète. Ne pas utiliser. Versione obsoleta. Non utilizzare. Verouderde versie. Niet gebruiken.

To Learn More. An Introduction to VNS Therapy. call or visit VNSTherapy.com

Patient Essentials. PATIENT S MANUAL for Heart Failure. June 2017

MRI SureScan pacemakers & ICDs what you need to know

IMAGEREADY MR CONDITIONAL PACING SYSTEM

Large External Fixator Modular Knee Bridge

Annual Associate Safety Module Magnetic Resonance Imaging (MRI)

MRI Information for Medtronic Spinal and Biologics Devices

URGENT FIELD SAFETY NOTICE Overconsumption following ElectroStatic Discharge or MRI scan

Bioness Inc Rye Canyon Loop Valencia, CA USA Telephone: or Website: Rx Only Bioness Inc.

Cardiac Rhythm Management // Manual // ProMRI. ProMRI. MR conditional device systems

Call Medtronic at 1 (800) to verify the patient s current implanted system

MRI Exams in Patients with Non MR Conditional Pacemakers and with MR Conditional Pacemakers

Understanding Peripheral

PATIENT PROGRAMMER 37642

Cardiac Rhythm Therapy // Advanced Features // ProMRI. ProMRI. Checklist and Quick Reference Guide

VNS Therapy Guide. For children and those with special needs with drug-resistant epilepsy

MEDTRONIC CARELINK NETWORK FOR PACEMAKERS. Comparison between the Medtronic CareLink Network for Pacemakers and Transtelephonic Monitoring

Revision A Date:

Button Plate. Reinforcement for transosseous fixations.

The Calcaneal Plate. The Synthes non-locking solution for the Calcaneus.

EasyStep. Operative technique

BEFORE AND AFTER YOUR MRI SCAN. For patients with St. Jude Medical neurostimulation systems for chronic pain

For Small-Statured Adults and Pediatric Patients. Medium External Fixator Basic Modular Frame

Implantation Procedure

Parkinson s disease, Essential Tremor and primary dystonia

DISTAL RADIUS. Instructions for Use

8/28/18. Anesthetic considerations for patients with implanted devices for treating chronic pain and more. Objectives:

TIP CARD. Model Temporary External Pacemaker

SJM MRI ACTIVATOR HANDHELD DEVICE WORKFLOW Model: EX4000. SJM-EDTR Item approved for U.S. use only.

St. Jude Medical 8-Channel Adapter. Clinician's Manual

User Manual: Ives MR Conditional Cup Electrodes J.R. Ives, December 22, 2017

Sacral Nerve Stimulation (SNS) System Implantation

Memo on The Safety of MRI Scanning of Coronary Artery Stents

BRING LIVING BACK TO LIFE. An Educational Booklet for Recipients of the Abbott Portico Transcatheter Aortic Valve

MRI SURESCAN SYSTEMS. Patient Scanning Process PATIENT PRESCREENING. SureScan Pacing, Defibrillation, and CRT-D Systems Verification

MRI and CIEDs. Disclosures

USING YOUR INTELLIS IMPLANTABLE SPINAL CORD STIMULATION SYSTEM

Large External Fixator Delta Frame Ankle Bridge. For staged fixation of the distal tibia.

Electrodes (for TransAeris System)

LCP Metaphyseal Plates. For extra-articular fractures.

Medium External Fixator Delta Frame Ankle Bridge

Pocket Adaptor Kit FOR SPINAL CORD STIMULATION. Tip Cards

The protection you need - without touching your heart

Distal Radius Plate 2.4/2.7 dorsal and volar

EXAMPLE PROTOCOL FOR PATIENT SCANNING PROCESS

CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART

Magnetic resonance imaging safety of NucleusR 24 cochlear implants at 3.0 T

PATIENT CONTROLLER ST. JUDE MEDICAL UNDERSTANDING IMPORTANT FEATURES ON YOUR

Prometra Programmable Pump System Brief Summary

Chronic pain Neurostimulation What is neurostimulation and how does it work? Neurostimulation is a proven, effective, reversible treatment

Transcription:

VNS Therapy System Physician s Manual Pulse Generator Model 102 Pulse Duo Generator Model 102R Demipulse Generator Model 103 Demipulse Duo Generator Model 104 AspireHC Generator Model 105 AspireSR Generator Model 106 Lead Model 302 PerenniaFLEX Lead Model 304 PerenniaDURA Lead Model 303 For Healthcare Professionals May 2015 U.S. Version Rx Only www.vnstherapy.com

MRI with the VNS Therapy System 285

13. MRI with the VNS Therapy System 13.1. Introduction 13.1.1. MR Conditional Device The VNS Therapy System is an MR Conditional device that has been shown to pose no known hazards in a specified magnetic resonance (MR) environment with specified conditions for use. For specific conditions refer to Conditional MR Environments for VNS. Note: For a definition of VNS and MRI terms, see the Glossary. Conditions that define an MRI environment include: Transmit RF coil used Field strength of the static magnetic field (Tesla) Spatial gradient of the static magnetic field (Gauss/cm) Time varying magnetic fields (db/dt) Radio frequency (RF) fields Specific absorption rate (SAR) In vitro tests have been performed with a variety of VNS Therapy Systems in a variety of MRI facilities. Numerical simulations of multiple patient sizes, and the VNS device in worst case and clinical configurations have been conducted. These tests have shown that VNS Therapy System patients may be safely exposed to certain MR environments if the guidelines described herein are followed. However, a risk of injury related to heating of the lead electrodes has been shown in other scenarios. Direct exposure of any part of the VNS System to an MR system RF transmit coil (local or body) can cause the lead electrodes to heat to temperatures that may cause pain, temporary injury, necrosis, or permanent tissue damage. In the case of a broken lead, the exposed lead wire is the point at which these injuries may take place. Caution: The VNS Therapy System lead can focus strong RF energy fields, such as those used during MRI, and cause excessive heating and possible injury if used outside of instructions provided herein. Worst case testing in an MR scanner has been performed on VNS System leads and generators. Due to similarity in construction and observed similarity in test results, VNS Therapy Systems that consist of Model 100C, 101, 102, 102R, 103, 104, 105, or 106 pulse generators and Model 300, 302, 303, or 304 leads are considered equivalent for MRI safety purposes. Specific programmable configurations of the VNS Therapy System device are also required before an MRI is performed. Note: For details, see Pre-MRI Preparation. 286

13.2. Potential Risks and Effects of MRI with VNS Note: For complete VNS indications, contraindications, warnings, and precautions, see the Introduction to the VNS Therapy System chapter. The potential risks of performing MRI on patients with an implanted VNS Therapy System include: Heating effects around the VNS Therapy System, especially electrodes, from RF energy Non-significant levels of current induced through the VNS lead wire by the time-varying gradient level Inadvertent device reset, which erases historical information stored on the device (possibly including device serial number) Inadvertent Magnet Mode activation (i.e., brief magnet application and removal, which initiates a stimulation) from magnetic fields For 106 only, delivery of AutoStim may occur if the feature is programmed on and a rapid increase in heart rate occurs Image distortion and artifacts Magnetic field interactions Device malfunction or damage Hazards from Cyberonics magnets (not implanted) in the vicinity of the MRI scan room 13.2.1. MRI-related Heating Effects Caution: Surgical removal of the VNS Therapy System will be required if MRI using a transmit RF body coil is needed. See the Revision / Replacement / Removal chapter for instructions. If the specific MRI conditions are not followed, tissue damage may result from excessive temperature increases at the electrode end of the lead during MRI scans. Damage to the vagus nerve and/or surrounding structures in the carotid sheath is of particular concern due to the location of VNS Therapy System stimulation electrodes. In vitro tests have shown clinically significant heating of the VNS Therapy System stimulation electrodes of up to a 30 C increase and higher during MRI scans of the head and/or body when the transmit RF body coil was used to apply RF energy. The degree of MRI-related heating observed is primarily influenced by location of the patient in the MR system and by lead wire configuration and length. Acceptable levels of heating, consistently less than a 2 C increase, were shown during in vitro tests and numerical simulations for specific types of MRI conditions (see Conditional MR Environments for VNS ). 287

13.2.2. Gradient Induced Current There is a potential risk that the device may reset due to the MRI environment. There is no safety risk to the patient from MRI gradient induced currents through the device s lead wire. By design, the VNS System delivers levels of current within a specified range on a scheduled duty cycle throughout the day. The currents induced by the MRI were measured, modeled, and demonstrated to be less than the lowest programmable VNS output. Any current induced in the lead by MRI time-varying magnetic fields may result in slight tingling sensation. 13.2.3. Device Reset There is no safety risk to the patient from a device reset. Some information (including serial number, implant date, stimulation parameters, and device operating time) may be lost from the VNS Therapy System pulse generator during a device reset. Most erased data can be reprogrammed, but device operating time cannot. Strong magnetic field gradients and RF energy, similar to that used to reset the pulse generator by design, are present in the MR environment. Pulse generator reset has not been observed during in vitro tests. A few cases of pulse generator reset have been reported by VNS patients in association with MRI procedures. Clinically, nothing can be done to prevent this rare occurrence. In the event of a device reset and loss of data, the VNS Therapy programming system should be used to reprogram the device serial number, implant date, and stimulation parameters to their pre-mri scan values. Note: For details on proper procedures to ensure data is not lost due to device reset, see Pre-MRI Preparation. 13.2.4. VNS Magnet Mode Activation Failure to program the Magnet Mode output to 0 ma may cause Magnet Mode activation by the MRI magnets leading to undesired stimulation. Magnet Mode activation is a frequent occurrence near MR systems. For this reason, the VNS Therapy System Normal Mode and Magnet Mode (as well as AutoStim Mode for Model 106) output currents should be programmed to 0 ma before patient entry into the MR system room. 288

13.2.5. Magnetic Field Interactions Caution: Lower static magnetic field strength does not imply greater safety. Because the primary hazard of MRI to VNS patients is MRIrelated heating, a lower static magnetic field strength and transmit frequency may present a greater hazard. Patients may feel a tugging sensation at the site of the pulse generator. The VNS Therapy System may experience magnetic field interactions associated with the static magnetic field of the MR system due to small amounts of material in the pulse generator sensitive to magnetic fields. This may cause the pulse generator to shift or move slightly within the implant pocket and/or may place mechanical stress on tissues and/or the lead. The VNS Therapy System lead does not directly experience magnetic field interactions, since it is made from nonferromagnetic materials. 13.2.6. Device Malfunction or Damage Tests in various MR systems have not shown damage to, or malfunction of, any VNS Therapy System. If device malfunction or damage were to occur, it could cause painful stimulation or direct current stimulation. Either event may cause nerve damage and other associated problems (See Adverse Events in the indicationspecific information chapters). If patients suspect a malfunction, they should be instructed to exit the MR system room and hold their magnet over their device to stop stimulation, and then contact their physician immediately for further evaluation. Prompt surgical intervention may be required if a malfunction occurs. 13.2.7. VNS AutoStim Mode (Tachycardia Detection - Activation) - Model 106 Only If Tachycardia Detection remains ON during the MRI, the MRI may contribute to false detections. If the AutoStim Mode output has not been programmed to 0 ma, the VNS Therapy System AutoStim Mode may be activated during the imaging, which may result in undesired stimulation. Specific testing of this mode in the MRI environment has not been performed. However, if this feature is deactivated prior to MRI, the Model 106 device is expected to behave in the same way as the other VNS pulse generators. The VNS Therapy System Normal Mode, AutoStim, and Magnet Mode output currents should be programmed to 0 ma, and Tachycardia Detection should be programmed OFF prior to patient entry into the MR system room. 13.3. MRI Guidelines MRI with the VNS Therapy System recommendations are based on phantom 1 tests and numerical simulations of worst-case and 289

recommended implant configurations of standard 43-cm bipolar VNS leads. The following guidelines pertain to full VNS Therapy Systems (generator and lead implanted). For guidance on performing scans on patients with abandoned leads or lead segments see Special cases and considerations. 13.3.1. Pre-MRI Preparation Because of the need to perform diagnostics and change programming parameters, an appropriate healthcare professional with access to a VNS Therapy programming system must prepare the VNS device before the patient enters an MR system room. To prepare the VNS device: 1. Perform an interrogation and record the following information in the patient record or on a copy of the table below. This information is used to restore the device settings in case of a reset. Caution: All VNS patients must have their VNS Therapy System assessed and programmed before an MRI procedure. Patient ID Device SN Implantation Date Output Current Signal Frequency Pulse Width Signal On Time Signal Off Time Mag. Current Mag. On Time Mag. Pulse Width Model 106 AutoStim Output Current Model 106 AutoStim Pulse Width Model 106 AutoStim On Time Model 106 Tachycardia Detection Model 106 Threshold for AutoStim Model 106 Heartbeat Detection 2. Perform System Diagnostics to ensure proper operation of the device. 1 Phantom A patient-equivalent form filled with gelled saline, used for in vitro tests of MRIrelated heating. 290

3. Reprogram the Output Current (OC) parameter settings for Normal Mode, Magnet Mode and AutoStim Mode as follows: Output Current (ma): 0 Mag. Current (ma): 0 AutoStim current (ma): 0 and Tachycardia Detection OFF (Model 106 only) Caution: Scanning of a patient with a VNS Therapy System located outside the C7-T8 exclusion zone has not been evaluated in preclinical testing. and therefore necessitates further evaluation by the MR System operator to verify that the device will not be exposed to the RF Field. 4. Perform a Device Interrogation 1 to verify programming was successful. 5. Verify that placement of the VNS Therapy System is located between C7-T8. Immediately before starting the MRI procedure, the patient should be instructed to notify the MR system operator of pain, discomfort, heating, or other unusual sensations so the operator can terminate the procedure, if needed. 13.3.2. Conditional MR Environments for VNS Non-clinical testing has demonstrated the VNS Therapy System is MR Conditional. 13.3.2.1. Precautions Note: See the Revision / Replacement / Removal chapter for instructions. Do not use the transmit RF body coil for 3 T or 1.5 T imaging, Surgical removal of the VNS Therapy System will be required if MRI using a transmit RF body coil is needed. Not all head RF coils are transmit and receive type. Many are receive only. The use of any local receive coil with the body coil in RF transmit mode presents the same RF heating hazards as the body coil alone with no local coils. Exposure of the VNS Therapy System to any RF transmit coil must be avoided. An exclusion zone has been defined in Figure 88. Surgical removal of the VNS Therapy System will be required if an MRI of the exclusion zone is needed. 13.3.2.2. 1.5 and 3.0 Tesla (T) conditions The VNS Therapy System can be scanned safely immediately after placement under the following conditions: Static magnetic field of 1.5 T or 3 T only 1 When an interrogation is performed by the programming software, the device serial number, implant date, stimulation parameters, and device operating time are automatically logged in the programmer database. This information may be retrieved from the database at any time after interrogation. (See the Programming Software Physician s Manual for further information.) 291

Spatial gradient field of 720 Gauss/cm or less Normal operating mode only Use only head or local transmit/receive coils. In non-clinical testing using a head transmit coil, the VNS Therapy System produced a maximum temperature rise of less than 2 C at a maximum head-averaged specific absorption rate (SAR) of 3.2 W/kg, which was determined by a validated calculation for 15 minutes of MRI scanning in a 1.5 T or 3 T scanner. Imaging the head with the transmit/receive RF head coil will not result in distortion of the image of the brain due to the presence of the electrodes, leads, or generator. Safety has not been demonstrated in patients with implanted devices in addition to VNS Therapy. MRI should not be performed in these patients until safety has been demonstrated. Note: Specific absorption rate (SAR) is a measure of RF power deposition in the patient, usually expressed in watts per kilogram (W/kg). For a given MR system, higher SAR leads to greater heating. For imaging VNS patients, SAR values are maximum head-averaged when using the transmit/ receive head coil. Caution: Not all head RF coils are transmit and receive type. Many are receive only. The use of any local receive coil with the body coil in RF transmit mode presents the same RF heating hazards as the body coil alone with no local coils. Caution: Exposure of the VNS Therapy System to any RF transmit coil must be avoided. 292

13.3.2.3. Special cases and considerations 13.3.2.3.1. Partially explanted VNS Therapy systems The primary risk of MRI to VNS patients is MRI-related heating of the lead. Testing and computer modeling have shown, however, that MRI can be performed safely under the following conditions: Note: See 1.5 and 3.0 Tesla (T) conditions for further guidelines. 1.5 T or 3 T with T/R Head Coil or T/R Extremity Coil If there is a suspected lead break (IPG is still connected) If any length (43 cm or less) remains (no IPG) 1.5 T or 3 T with transmission of RF with the Body Coil (any landmark) If there is 2 cm of lead (i.e., electrodes remain implanted) 13.3.2.3.2. Assessing lead segment length If an MR image is needed and must be obtained using the body coil, a safe length of lead segment remaining (i.e., 2 cm) implanted can be assessed by taking an x-ray. The length of 2 cm can be approximated by visualizing the distance between the positive and negative electrode (~1 cm). By design, there is approximately 1 cm between the positive electrode and the anchor tether, which is also likely remaining. Surgeons are instructed to remove as much of the lead as possible if explanting a system. Figure 84 illustrates the relationship of the electrodes to each other and the positive electrode to the anchor tether. An MRI using the Body coil for transmission of RF, or MRI of the head or extremities with a Head coil or Local (Extremity) coil (respectively) for transmission of RF is allowed if the lead is transected as seen in Figure 84. Figure 84. Transected Lead ( 2 cm) 293

If the lead is transected as seen in Figure 85, only a T/R head MRI or T/R extremity MRI is recommended. A full body MRI is not allowed. Figure 85. Transected Lead (> 2 cm) Warning: If it appears that more than 2 cm of lead remains, then the patient cannot have an MRI with the body coil, but can still have an MRI using a local T/R or head T/R coil as instructed in this chapter. Abandoned lead wires present increased risk of thermal injury to patients during MRI procedures based on their length and their exposure to RF. 13.3.2.3.3. 1.5 and 3.0 MR imaging scenarios Figure 86. Head MR Imaging Note: The crosshairs indicate the iso-center of the MR system s bore. Area of Interest: Brain Transmit RF Coil: Head Brain scans are performed using a transmit/receive RF head coil, which results in minimal or no exposure of VNS to RF energy. 294

Figure 87. Lower Extremity MR Imaging Area of Interest: Knee, Ankle Transmit RF Coil: Local Caution: Exposure of the VNS Therapy System to any RF transmit coil must be avoided. Scans of extremities are performed using an appropriate transmit/ receive local coil, which results in minimal or no exposure of VNS to RF energy. Although not illustrated, MRI scans of the wrist are also possible using an appropriate transmit/receive local coil. 13.3.2.4. Unsafe MR conditions In vitro MRI-related heating tests with the transmit RF body coil have shown potentially injurious temperature increases; therefore, scans should not be performed on patients with VNS under the following conditions: Note: For instructions specific to scanning patients with abandoned leads where use of the body coil for transmission of RF may be permissible, see Special cases and considerations. Note: Testing was only performed using closed (i.e., cylindrical) MRI scanners. Magnetic resonance imaging (MRI) should not be performed with a magnetic resonance body coil in the transmit mode. Under no circumstances should the local transmit coil be placed over the VNS System. Because of this restriction, scanning of the area where the VNS System is implanted is not possible. See Figure 89 for details. Open MRI scanners should not be used for scanning VNS patients. Systems other than 1.5 T and 3 T should not be used for scanning VNS patients. 295

13.3.2.4.1. Unsafe MR imaging scenarios Figure 88. Unsafe MR - Exclusion Zone Caution: This exclusion zone is dependent upon the typical placement of the VNS Therapy System and cannot be scanned under any circumstances. Area of Interest: C7-T8 Exclusion Zone Transmit RF Coil: All types The VNS Therapy System, usually located between C7 and T8, must not be exposed to any RF field from a RF transmit coil. Surgical removal of the VNS Therapy System will be required if an MRI of the exclusion zone is needed. See the Revision / Replacement / Removal chapter for instructions. Figure 89. Unsafe MR Imaging Note: The crosshairs indicate the iso-center of the MR system s bore. Area of Interest: Any Transmit RF Coil: Body 13.3.2.5. MR unsafe devices The VNS Therapy programming system, including the programming wand and the programming computer are MR Unsafe. The patient magnet is also MR Unsafe. These devices must not be brought into the MR scanner room. Many VNS patients or caregivers carry magnets to activate and inhibit the VNS Therapy System. A small magnet, which can attach to a wristband or belt clip, is included in the kit given to all VNS 296

patients. The magnet may be accidentally carried into an MR scan room, where it could cause damage or injury if it becomes a projectile. Figure 90. MR Unsafe Devices Programming Wand and Programming Computer Patient Magnet 13.3.3. Post-MRI Assessment After the MRI procedure, an appropriate healthcare professional with access to a VNS Therapy programming system should assess the condition of the VNS Therapy System. To assess the VNS Therapy System: 1. Interrogate the VNS device. Note: For a complete list of information needed to restore the device settings, see Pre-MRI Preparation. 2. If the pulse generator was reset during the scan, reprogram the serial number, patient ID, and implant date, as needed. 3. Program the patient s therapeutic parameters as they were before the MRI procedure. 4. Perform System Diagnostics. Results should indicate Impedance = OK. 5. Interrogate the device again to confirm that reprogramming was successful. 297

Information and Support 75-0000-1600/3 (Worldwide) 14. INFORMATION AND SUPPORT If there are questions regarding use of the VNS Therapy System or any of its accessories, contact Cyberonics: Manufacturer Cyberonics, Inc. 100 Cyberonics Boulevard Houston, Texas 77058 USA Tel: +1 (281) 228-7200 1 (800) 332-1375 (US and Canada) Fax: +1 (281) 218-9332 Authorized Representative Europe Cyberonics Europe, BVBA Airport Plaza - Kyoto Building Leonardo Da Vincilaan 19 B-1831 Diegem, Belgium Tel: +32.2.720.95.93 Fax: +32.2.720.60.53 24-hour Clinical Technical Support Tel: 1 (866) 882-8804 (US and Canada) +1 (281) 228-7330 (Worldwide) +32 2 790 27 73 (Europe/EMMEA) Internet www.vnstherapy.com 300