An fmri Phantom Based on Electric Field Alignment of Molecular Dipoles

Similar documents
P2 Visual - Perception

Classification and Statistical Analysis of Auditory FMRI Data Using Linear Discriminative Analysis and Quadratic Discriminative Analysis

Functional MRI Mapping Cognition

Titelmaster The physics of functional magnetic resonance imaging (fmri)

Table 1. Summary of PET and fmri Methods. What is imaged PET fmri BOLD (T2*) Regional brain activation. Blood flow ( 15 O) Arterial spin tagging (AST)

Q-Sense fmri in the MRI environment

Optical Illusions and Human Visual System: Can we reveal more? CIS Micro-Grant Executive Report and Summary of Results

The physiology of the BOLD signal What do we measure with fmri?

Methods for assessing the brain basis of developmental disorders

RECENT ADVANCES IN CLINICAL MR OF ARTICULAR CARTILAGE

PHYSICS OF MRI ACQUISITION. Alternatives to BOLD for fmri

Announcements. Final Exam will be a take-home exam. Format similar to the short assignment (no multiple choice, etc.)

Cardiac MRI at 7T Syllabus contribution: Matthew Robson

Removal of Nuisance Signal from Sparsely Sampled 1 H-MRSI Data Using Physics-based Spectral Bases

Procedia - Social and Behavioral Sciences 159 ( 2014 ) WCPCG 2014

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Knee Implants

ACR MRI Accreditation Program. ACR MRI Accreditation Program Update. Educational Objectives. ACR accreditation. History. New Modular Program

An Unified Approach for fmri-measurements used by a New Real-Time fmri Analysis System

Functional Magnetic Resonance Imaging with Arterial Spin Labeling: Techniques and Potential Clinical and Research Applications

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Shoulder Implants

Turbo ASL: Arterial Spin Labeling With Higher SNR and Temporal Resolution

FLORIDA STATE UNIVERSITY NEWS THE OFFICIAL NEWS SOURCE OF FLORIDA STATE UNIVERSITY. FSU unveils Florida s most advanced MRI machine

INTRO TO BOLD FMRI FRANZ JOSEPH GALL ( ) OUTLINE. MRI & Fast MRI Observations Models Statistical Detection

BOLD signal dependence on blood flow and metabolism. Outline

Initial Clinical Experience of TOSHIBA 3T MRI

Concurrent near-infrared spectroscopy (NIRS) and functional magnetic resonance imaging (fmri) of the brain

Why measure heart iron?

ACR Accreditation Update in MRI

MRI/MRS Biomarkers. Robert E. Lenkinski, Ph.D.

Intrinsic Signal Optical Imaging

Problem Set #8 Rad 226

BOLD signal compartmentalization based on the apparent diffusion coefficient

MR QA/QC for MRgRT. Rick Layman, PhD, DABR Department of Radiology July 13, 2015

A. DeWerd. Michael Kissick. Larry. Editors. The Phantoms of Medical. and Health Physics. Devices for Research and Development.

EEG-Correlated Functional MRI: Recent Methodologic Progress and Current Issues

COGNITIVE SCIENCE 17. Peeking Inside The Head. Part 1. Jaime A. Pineda, Ph.D.

Syllabus References. Resources. Video: MRI Introduction

Daniel Bulte. Centre for Functional Magnetic Resonance Imaging of the Brain. University of Oxford

Overview. Fundamentals of functional MRI. Task related versus resting state functional imaging for sensorimotor mapping

Publication for the Philips MRI Community Issue 39 December 2009

Visualization strategies for major white matter tracts identified by diffusion tensor imaging for intraoperative use

Clinically Available Optical Topography System

Breakout Session 1: Image Acquisition

Simultaneous Acquisition of Cerebral Blood Volume-, Blood Flow-, and Blood Oxygenation-Weighted MRI Signals at Ultra-High Magnetic Field

ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS

MR Advance Techniques. Vascular Imaging. Class II

Repeatability of 2D FISP MR Fingerprinting in the Brain at 1.5T and 3.0T

Supplementary Online Content

Supplementary information Detailed Materials and Methods

Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR Imaging

Development of Ultrasound Based Techniques for Measuring Skeletal Muscle Motion

COMPUTED TOMOGRAPHY COURSE

*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Hip Implants

Hemodynamics and fmri Signals

Functional Chest MRI in Children Hyun Woo Goo

APPLICATION AND DEPLOYMENT OF ADVANCED NDE TECHNIQUES IN HIGH PRESSURE VESSELS

MRI Guidelines for the Axonics Sacral Neuromodulation System

Introduction. Cardiac Imaging Modalities MRI. Overview. MRI (Continued) MRI (Continued) Arnaud Bistoquet 12/19/03

BioMatrix Tuners: CoilShim

TG-128: Quality Assurance for Prostate Brachytherapy Ultrasound

Cover Page. The handle holds various files of this Leiden University dissertation

MRI GUIDELINES FOR INSPIRE THERAPY

Biophysical and physiological bases of fmri signals: challenges of interpretation and methodological concerns

JiangSu Magspin Instrument Co., Ltd

Hemodynamics and fmri Signals

High-resolution T 2 -reversed magnetic resonance imaging on a high-magnetic field system Technical note

Contributions to Brain MRI Processing and Analysis

A quality control program for MR-guided focused ultrasound ablation therapy

Perfusion-Based fmri. Thomas T. Liu Center for Functional MRI University of California San Diego May 7, Goal

Introduction to simultaneous EEG-fMRI

PINPOINTING RADIATION THERAPY WITH THE PRECISION OF MR.

Biomedical Imaging: Course syllabus

MRI GUIDELINES FOR INSPIRE THERAPY

Introduction to Functional MRI

Choosing the metabolomics platform

Lions Gate Secondary Wastewater Treatment Plant

Investigations in Resting State Connectivity. Overview

Functional Magnetic Resonance Imaging

5/2/2013. Real-time fmri: Methods and applications

Define functional MRI. Briefly describe fmri image acquisition. Discuss relative functional neuroanatomy. Review clinical applications.

Magnetization Preparation Sequences

Magnetic resonance imaging safety of NucleusR 24 cochlear implants at 3.0 T

Routine Quality Assurance Cookbook

Perfusion Physics. ICMRI2018 March 29-31, 2018 Grand Hilton Hotel, Seoul, Korea. Asian Forum Ⅱ: Perfusion MRI SY24-1.

ULTRASOUND QA SOLUTIONS. Ensure Accurate Screening, Diagnosis & Monitoring DOPPLER FLOW PHANTOMS MULTI-PURPOSE PHANTOMS TRANSDUCER TEST PHANTOMS

Assessment of longer post-labeling delays to measure CBF using pseudo-continuous ASL with background suppression

POSITION TITLE: Sr. Research Imaging Specialist, Vanderbilt University Institute of Imaging Science

Progress Report. Author: Dr Joseph Yuan-Mou Yang Qualification: PhD Institution: Royal Children s Hospital Date: October 2017

Brain and Cognition. Cognitive Neuroscience. If the brain were simple enough to understand, we would be too stupid to understand it

The Effects of Music intervention on Functional connectivity. Supplemental Information

ASL BASICS II. Learning Objectives. Outline. Acquisition. M. A. Fernández-Seara, Ph. D. Arterial spin labeled perfusion MRI: basic theory

Ultrasound its place in medical diagnostics

How Much Tesla Is Too Much?

The Tools: Imaging the Living Brain

APPLICATIONS OF ASL IN NEUROSCIENCE

An introduction to functional MRI

fmri Acquisition: Temporal Effects

Automated Practical System Qualification, Validation and Reporting acc. ASTM E

Neuroimaging vs. other methods

Basics of Quantification of ASL

Transcription:

An fmri Phantom Based on Electric Field Alignment of Molecular Dipoles Innovative Graduate Student Proposal Yujie Qiu, Principal Investigator, Graduate Student Joseph Hornak, Faculty Sponsor, Thesis Advisor Chester F. Carlson Center for Imaging Science Rochester Institute of Technology Abstract Multi-center fmri research has been carried out in many institutes and universities because it has many advantages such as larger sample size, more disease cases, and so on. But the differences between magnetic imaging systems setup at different sites makes the data hard to combine and difficult to interpret. Some groups have made their own phantoms to address this problem but there are still some questions left. We proposed to build a new phantom based on electric field alignment of molecular dipoles. This phantom not only simulates the T * 2 change during the fmri experiments but also eliminating the metallic effect and moving parts. This proposal seeks funds for partial support of the principal investigator to carry out the project. Dollar Request: $5,000.00 Desired Funding Dates: January 1 through May 30, 2011

Scientific justification Function magnetic resonance imaging (fmri) opens a new window for us to explore how the brain works without cutting it open. The magnetic susceptibility difference caused by the change of T 2 *, which is the combination of the spin-spin relaxation time (T 2 ) and the effect due to magnetic field inhomogeneities, between oxygenated hemoglobin and deoxygenated hemoglobin makes it possible for fmri to detect the active functional region or find the connectivity among the active regions when people perform a specific task like tapping fingers or reading books. However, this blood-oxygenation-level dependent (BOLD) effect is quite small. When buried in non-uniform noise and various physiological fluctuations, these weak and valuable signals are quite hard to obtain via subtracting the average image of the control task from the average image of the active task. [1] Therefore, the commonly employed method at present is to get statistical maps from the fmri data. Statistical knowledge tells us that the larger the sample size, the more approximate the result is to the real answer. Unfortunately, the number of subjects who are willing to do the fmri experiment is always limited for every research site. Sometimes even though the sample size is not a problem, the misunderstanding of the tasks and motion during the experiment would ruin the data and result in unreliable results. In order to reduce the influence brought by these circumstances, it is ideal to strengthen the collaboration of fmri research sites, hence every site can take advantage of the data acquired from other sites. This measure is particularly useful for some rare diseases. Some research institutes and universities have begun to build such an organization and carried out many meaningful experiments. [2] But are all the data coming from different sites comparable and able to use the same software to do the statistical analysis? This question is not easy to answer. Nowadays there are three major MRI whole-body manufacturers (GE, Siemens, and Philips) set up at most research sites. They have different magnetic field strength (1.5T, 3T, or 4T), are equipped with different head coils, and employ different pulse sequences, and reconstruction methods. Casey et al. [3] found the reproducibility of fmri results from multicenter research but also observed the differences among the sites. At this moment, quality assurance seems quite important. Usual quality control ways involve resolution and RF homogeneity test via special constructed phantoms, [4] which are aimed at relative static signals, while fmri signals are changing during the experiment. It will be better if there is a phantom capable of simulating signal changes between the control and active task. Some groups have thought about the idea of designing a special phantom for fmri quality control and two types of phantom have been made. One (Type I) is to fill the phantom with special material which has similar spin-lattice relaxation time (T 1 ) and T 2 to that of the gray matter of the brain. What Friedman et al. [5] and Olsrud et al. [6] constructed is such kind of phantom. The difference between these two groups is that Friedman only designed a static phantom to test the stability of the system performance and Olstrud s purpose was to mimic the active and control status of the brain. He concocted two solutions with only a tiny disparity in T 1, T 2, and T 2 *. When doing the experiment, the control part or the active part is physically moved into the center of the coil. This kind of phantom is easy to make and the mixture of agarose is homogeneous and will not lead to magnetic field inhomogeneities. However, it is not convenient to switch the control status to active or vice versa during the experiment. In addition, for

different strength of magnetic field, the relaxation times (T 1, T 2 and T * 2 ) are different, which means for every system with different magnetic field, an exclusive phantom should be made. Last but not the least, agraose may degrade over time, so some preservative should be added or the phantom should be checked regularly. The other type of phantom (Type II) did not use the same mechanism to mimic the BOLD signal. Researchers employed electronic properties to alter the signal but not through the relaxation time changes. Renvall et al. [7] utilized a current-induced magnetic field to change the local applied magnetic field (B o ) near an electric conductor. Cheng et al. [8] utilized a radio frequency (RF) resonant circuit to change the RF magnetic field (B 1 ) so that different signals were obtained. These kinds of phantoms contain metallic parts within the field-of-view (FOV) which will affect the magnetic field homogeneity. Their strength is that it is easy to synchronize the signal change to the fmri experiment. Our idea is inspired by Jone s paper [9] which showed that with the application of an electric field, some polar liquids undergo a change in their T 1 value. If these liquids are used as the filling of our phantom, we can simulate the changes between control and active status during the fmri experiments by changing the strength of the electric field. Compared to the Type II phantom, our phantom only has small metallic parts that can be placed outside the FOV. In other words, our phantom possesses the advantages of both Type I and Type II phantoms, which simulate the BOLD signal through the same mechanism and is simple to alter the intensity of the signal. To pursue this research, we first need to determine the change in T 1, T 2, and T * 2 of different polar liquids with an applied electric field. Only by knowing this information can a proper polar liquid be selected. These values will be measured on RIT s 300 MHz NMR spectrometer with a to be constructed sample holder across which an electric field can be applied. The specific pulse sequences are: 1) Inversion Recovery pulse sequence to measure T 1, 2) Multi-echo spin-echo sequence to measure T 2, and 3) Gradient-echo echo-planar imaging sequence to measure T * 2. After appropriate polar liquid is determined, a phantom will be constructed. The additional tasks which will be performed are: 1) Use an echo planar imaging sequence to acquire the fmri images, and 2) Optimizing acquisition parameters. When the data are collected from the imager, they will be transferred to and stored in one of the CIS computer for processing. SPM and AFNI are popular in fmri filed and both of them are free. [10] We will use these two software packages to analyze the data acquired from our phantom and validate its effectiveness. In summary, by constructing this phantom, we will gain a deeper understanding of the data acquisition procedure from the fmri experiment and how it can vary from site to site or machine to machine. By becoming familiar with the SPM and AFNI data processing software, we will be able to incorporate a phantom into a patient/volunteer imaging protocol and provide a new method to ensure the stability of the systems used in multi center studies. This should promote the collaboration of the institutes and get more reliable results from the fmri data.

Budget Request The proposed project is expected to take several years to complete. This proposal only covers the PI s effort for a portion (5 months) of this period. During this period, the PI will devote 100% of her time to this research and thus the requested funds will be used to support her stipend. The advisor will provide the polar liquids and material to make the phantom. The total funds requested are $5,000. Table 1. Proposed budget for phantom research Category Item Period Effort Amount Personal Graduate Stipend Jan. May 2011 $5000 Total $5000 Project plan The goal of this project is to make an fmri phantom to do the quality control to ensure the reproducibility of the results and comparableness of the data acquired from the multi-centers. The proposed job is expected to take two years to complete. The timeline, outcome and milestone are listed in Table 2. The first three milestones are expected to achieve during the funded period, while the others will be fulfilled in two years. The NMR spectrometer and MR imager will be made an appointment when needing to use. Table 2. Project Plan Milestone Measure T 1 and T 2 of some polar liquids using NMR spectrometer Add electric potentials and measure these T 1 and T 2 using different current levels Design and build a phantom for use on an MRI Measure T 1, T 2, and T * 2 of the phantom at 1.5 and 3.0 T. Acquire real fmri experiment data on a magnetic resonance imager Analyze the experimental results using SPM and AFNI Time Line Jan Feb Mar Apr May x x x x x x Outcome Determine the proper polar liquid will be used Build an phantom for fmri quality control Find the differences among these parameters in different sites Master the procedure of how to perform fmri experiments Evaluate the phantom

References [1] R. B. Buxton, Introduction to functional magnetic resonance imaging : principles and techniques. Cambridge, UK ; New York: Cambridge University Press, 2002. [2] D. I. Kim, et al., "Auditory oddball deficits in schizophrenia: an independent component analysis of the fmri multisite function BIRN study.," Schizophr Bull, vol. 35, pp. 67-81, Jan 2009. [3] B. J. Casey, et al., "Reproducibility of fmri results across four institutions using a spatial working memory task.," Neuroimage, vol. 8, pp. 249-61, Oct 1998. [4] J. P. Hornak, The Basics of MRI. Available: http://www.cis.rit.edu/htbooks/mri/, 2010 [5] L. Friedman and G. Glover, "Report on a multicenter fmri quality assurance protocol.," J Magn Reson Imaging, vol. 23, pp. 827-39, Jun 2006. [6] J. Olsrud, A. Nilsson, P. Mannfolk, A. Waites, and F. Ståhlberg, "A two-compartment gel phantom for optimization and quality assurance in clinical BOLD fmri.," Magn Reson Imaging, vol. 26, pp. 279-86, Feb 2008. [7] V. Renvall, R. Joensuu, and R. Hari, "Functional phantom for fmri: a feasibility study.," Magn Reson Imaging, vol. 24, pp. 315-20, Apr 2006. [8] H. Cheng, et al., "SmartPhantom--an fmri simulator.," Magn Reson Imaging, vol. 24, pp. 301-13, Apr 2006. [9] G. P. Jones, A. Bradbury, and P. A. Bradley, "Electric Field Induced Changes of Spin Lattice Relaxation Time T1 in Polar Liquids," Mol. Cryst. Liq. Cryst., vol. 55, p. 7, 1979. [10] S. A. Huettel, A. W. Song, and G. McCarthy, Functional magnetic resonance imaging. Sunderland, Mass.: Sinauer Associates, Publishers, 2004.