Application Note # MT-91. High Quality MALDI Imaging of Proteins and Peptides in Small Rodent Organ Tissues. Bruker Daltonics.

Similar documents
Technical Note # TN-31 Redefining MALDI-TOF/TOF Performance

Application Note # MT-111 Concise Interpretation of MALDI Imaging Data by Probabilistic Latent Semantic Analysis (plsa)

Small Molecule Drug Imaging of Mouse Tissue by MALDI-TOF/TOF Mass Spectrometry and FTMS

Bruker Daltonics. autoflex III smartbeam. The Standard in MALDI-TOF Performance MALDI-TOF/TOF. think forward

MALDI Imaging Drug Imaging Detlev Suckau Head of R&D MALDI Bruker Daltonik GmbH. December 19,

Normalization in MALDI-TOF imaging datasets of proteins: practical considerations

MALDI-IMS (MATRIX-ASSISTED LASER DESORPTION/IONIZATION

Sequence Identification And Spatial Distribution of Rat Brain Tryptic Peptides Using MALDI Mass Spectrometric Imaging

The study of phospholipids in single cells using an integrated microfluidic device

Application Note # MT-94 Direct Read-out of Thin Layer Chromatography (TLC) using MALDI-TOF

FPO. Label-Free Molecular Imaging. Innovation with Integrity. Discover, localize and quantify biochemical changes and molecular markers

Supporting information for

Application Note # FTMS-46 solarix XR: Analysis of Complex Mixtures

Application Note # ET-17 / MT-99 Characterization of the N-glycosylation Pattern of Antibodies by ESI - and MALDI mass spectrometry

Supporting Information. Evolution of atomically precise silver clusters to superlattices

Isolation of pure cell populations from healthy and

Three Dimensional Mapping and Imaging of Neuropeptides and Lipids in Crustacean Brain

Imaging Mass Microscope

LOCALISATION, IDENTIFICATION AND SEPARATION OF MOLECULES. Gilles Frache Materials Characterization Day October 14 th 2016

The J105 SIMS. A New Instrument for 3-Dimensional Imaging and Analysis. Paul Blenkinsopp, Ionoptika Ltd

Future Directions: Tissue and Cell Imaging Robert C. Murphy

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

Application Note # LCMS-89 High quantification efficiency in plasma targeted proteomics with a full-capability discovery Q-TOF platform

Solid-in-oil peptide nanocarriers for transcutaneous cancer vaccine delivery. against melanoma

MALDI Mass Spectrometry: A Label-Free Solution for Ultra-High-Throughput Screening

INTRODUCTION TO MALDI IMAGING

18 Urinary system. 19 Male reproductive system. Female reproductive system. Blok 11: Genital and Urinary Tract Diseases

MALDI Imaging Mass Spectrometry

MS-IMS (MALDI-IMAGING)?

PUBLISHED VERSION Gustafsson JOR, et al. PERMISSIONS.

Nature Neuroscience: doi: /nn Supplementary Figure 1. Large-scale calcium imaging in vivo.

Clinical Microbiology

Protein and peptides in pictures: Imaging with MALDI mass spectrometry

The MALDI Biotyper An In Vitro Diagnostic System (IVD) for Identification of Bacteria and Yeasts with a Global Reach

Mass Spectrometry. Actual Instrumentation

An optical dosimeter for the selective detection of gaseous phosgene with ultra-low detection limit

Expression of acid base transporters in the kidney collecting duct in Slc2a7 -/-

Data Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section

TissueSurgeon Hard Tissue Applications

The topic of normal vascular and glomerular anatomy is introduced

MALDI Sepsityper Kit

Application Note FTMS-53+MT-115 MALDI Imaging Success Stories in Clinical Research Mini Review

Nature Neuroscience doi: /nn Supplementary Figure 1. Characterization of viral injections.

Neural stem cells and the neurobiology of ageing. Chen Siyun 1, Dawe G.S. 2

Nanostructured ZnO as a solution-processable transparent electrode material for low-cost photovoltaics

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography

Supporting Information

Pt 8 mm. 12 mm ITO ~ Figure S1. Top view of the Pt-IDA electrode on the glass slide with 50-µm and 50-µm

Synthesis and Characterization of Mn 2+ Doped Zn 2. Phosphor Films by Combustion CVD Method

Automated Sample Preparation/Concentration of Biological Samples Prior to Analysis via MALDI-TOF Mass Spectroscopy Application Note 222

Matrix Assisted Laser Desorption Ionization Time-of-flight Mass Spectrometry

Using Infrared and Raman Microspectroscopies to Compare Ex Vivo Involved Psoriatic Skin and Normal Human Skin

New Instruments and Services

Bruker Daltonics. Introduction

The time has come: SINGLE CELL western blotting. Parrinello Natalia TJC

Supporting information for: Memory Efficient. Principal Component Analysis for the Dimensionality. Reduction of Large Mass Spectrometry Imaging

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

MALDI-TOF analysis of whole blood: its usefulness and potential in the assessment of HbA1c levels

Proteomic Biomarker Discovery in Breast Cancer

SUMMARY. Keywords: quail, Coturnix japonica, morphology, ovary, oviduct, neurotrophins, immunohistochemistry

SOM Husse et al. Supplementary online material. Synaptotagmin10-Cre, a driver to disrupt clock genes in the SCN

Desorption Electrospray Ionization Coupled with Ultraviolet Photodissociation for Characterization of Phospholipid Isomers in Tissue Sections

Multimodal and multispectral imaging approaches to study the diffusion of pepsin during in vitro digestion of meat

Applications for MALDI-TOF Imaging Present and Future

Molecular Cartography:

Keeping an Eye on Molecular Imaging: Drug Efficacy & Toxicity in Ophthalmology

Optical Properties of Aligned Zinc Oxide Nanorods

New Instruments and Services

Modeling of Hippocampal Behavior

Systematic analysis of protein-detergent complexes applying dynamic light scattering to optimize solutions for crystallization trials

C a t a r a c t G l a u c o m a R e t i n a R e f r a c t i v e. The GDxVCC Early answers and ongoing assessment for glaucoma

Cover Page. The handle holds various files of this Leiden University dissertation

Bildgebende Massenspektrometrie Erfolgreiche Anwendungen in der biomedizinischen Forschung. Markus Stoeckli

Plasticity of Cerebral Cortex in Development

Analysis of Peptides via Capillary HPLC and Fraction Collection Directly onto a MALDI Plate for Off-line Analysis by MALDI-TOF

Reversible Formation of Ag 44 from Selenolates

Biological Mass Spectrometry. April 30, 2014

On the Dynamics of Kefir Volatome

Brooke Dilmetz. Quantitation of PFAS using MALDI-TOF MS

A pillar[2]arene[3]hydroquinone which can self-assemble to a molecular zipper in the solid state

Suppl. Information Supplementary Figure 1. Strategy/latency analysis of individual mice during maze learning. a,

PosterREPRINT A NOVEL APPROACH TO MALDI-TOF-MS SAMPLE PREPARATION. Presented at ABRF 2002, Austin, Texas, USA, 9th - 12th March 2002.

Supplementary Information

Morphogenesis of the residual body of the mouse testis

A systematic investigation of CID Q-TOF-MS/MS collision energies to allow N- and O-glycopeptide identification by LC-MS/MS

Alere Technologies GmbH

Solution range. Superior accuracy in surface interaction analysis

Qualitative & Quantitative MS imaging technique for BAK distribution in eye. Stauber Jonathan, PhD CSO ImaBiotech

A&P 2 Endocrine Pre-Lab Guide Information from Videos and Exercises

Supplementary Information

LYMPH GLAND. By : Group 1

Epithelium tissue system

Utility of neurological smears for intrasurgical brain cancer diagnostics and tumour cell percentage by DESI-MS

Characterization of Zinc Oxide Nanolaminate Films. B. J. Oleson, L. M. Bilke, J. S. Krueger, S. T. King

Distinction layer by layer. HRT II Rostock Cornea Module

Tissue Profiling by MALDI-Tof MS: Basic Principles From Small Molecules to Proteins

Supplementary Figure S1: Histological analysis of kainate-treated animals

Supplementary Figure 1. ACE robotic platform. A. Overview of the rig setup showing major hardware components of ACE (Automatic single Cell

Exercise 6. Procedure

THE EFFECTS OF LIGATION OF CAUDA EPIDIDYMIDIS ON THE DOG TESTIS

Transcription:

Bruker Daltonics Application Note # MT-91 18385 Da 6230 Da 7843 Da High Quality MALDI Imaging of Proteins and Peptides in Small Rodent Organ Tissues New developments in MALDI instrumentation, laser technology and sample preparation techniques have turned research-style MALDI imaging of proteins and peptides into a routine technique. To evaluate the potential of MALDI imaging with regard to the resolution and information content of the images that can be obtained, biological systems with well-defined structures on both the macroscopic and microscopic level are helpful. Organs of small mammals, such as the brain, kidney, testis, pancreas and spleen of mice or rats have these desired properties and are easily accessible. For these reasons, they are preferred samples for MALDI imaging method development. In this application note we present the current state-of-the-art in MALDI imaging of rodent organs. Introduction Over the last few years the popularity of MALDI imaging has increased tremendously. The high potential of MALDI imaging is best recognized in cancer research, where murine organs are often used as model systems. In addition, they represent preferred samples for method development and evaluation of the technique. The main reasons for this, aside from the easy accessibility, ethical implications and sample handling (compared to human tissue), are the size and the clear macroscopic structure of most murine organs. For example, the main features of a mouse kidney are obvious, even to an untrained observer. Coronal brain sections, due to their clear left-right symmetry, are particularly well suited for direct comparison of different experimental parameters. With the introduction of the Bruker ImagePrep system, sample preparations that allow spatial resolution of 50 100 μm or better can be routinely achieved for the first time. Model systems with defined anatomical features of this scale are therefore necessary to evaluate the possibilities of sample preparation. To demonstrate the current possibilities in MALDI imaging, this work shows MALDI images of several rodent organs acquired with the MALDI Molecular Imager system. Experimental Rat organs were snap frozen in liquid nitrogen and stored at -80 C before use. Cryosections for MALDI imaging were cut on a Cryo-microtome (Leica) and transferred onto cold Indium-Tin-Oxide (ITO) coated glass slides. To thawmount the tissue sections, glass slides were warmed from underneath with the palm of a hand. Sections were then desiccated in vacuum for 5 min, washed twice in 70 % Ethanol and once in 100 % Ethanol for one minute each, then desiccated again. Matrix coating was applied in an

ImagePrep TM station using the pre-installed standard method for sinapinic acid. Spectra were acquired on an autoflex III mass spectrometer with smartbeam laser in linear mode (200 400 laser shots per pixel). fleximaging software (Bruker Daltonics) was used for the visualization and analysis of MALDI images that were acquired at image resolutions from 80-240 µm. For accurate alignment of MALDI images and histological features, H&E staining of the same kidney section was performed after MALDI analysis (postacquisition staining). Mass signal overlay Spermatozoa development Testis Epididymis Fig. 1a: Rat testis: The maturation occurs during Spermatozoa migration from testis to epididymis. m/z = 5470 Da m/z = 6177 Da m/z = 18746 Da Fig. 1b: The overlay of three specific peptides in different colors shows tubule walls, spermatozoa, and different developmental stages simultaneously. 80 µm image resolution is mandatory to resolve these structures. Scalebar: 1 mm Sample courtesy of Charles Pineau, Rennes, France Molecular masses correspond with maturation of the spermatozoa Optical image 2922 Da 3460 Da 4811 Da 4936 Da 5006 Da 5149 Da 5357 Da 5470 Da 6177 Da 6263 Da 9559 Da 9778 Da 9852 Da 18746 Da Fig. 1c: Several peptides correspond to the maturation of spermatozoa or tissue morphology. Spermatozoa in the tubuli can be clearly correlated to different peaks. Images taken at 80 μm resolution. Scalebar: 1 mm

Resolution Matters! 80 µm 160 µm 240 µm Fig. 1d: Rat epididymis image analysis at varying image resolution (80 µm, 160 µm and 240 µm pixel size). Tubuli (red) are clearly resolved at 80 µm but not at lower image resolution. Scalebar: 1 mm Results Rat testis / epididymis The testis/epididymis is a good model to evaluate the correlation of MALDI images with conventional histology, since it shows very distinct anatomical features at different scales. The development of spermatozoa begins in the testis and continues along the epididymis (Fig 1a). Changes in protein expression patterns along this path coincide with the maturation of spermatozoa: Several protein signals corresponding with the maturation of the spermatozoa can be detected (Fig. 1c). On a smaller scale, spermatozoa migrate inside tubuli, which can be seen as dark islands in the optical image in Fig. 1b. The good MALDI image resolution obtained using the ImagePrep (down to 25 µm, here: 80 µm pixel size) is particularly noteworthy, as it allows a clear distinction between tubule wall and lumen. In Fig. 1b an overlay of three mass signals shows tubuli walls, spermatozoa and different development stages at the same time. The tubuli of the epididymis represent a structure that can only be resolved at a high image resolution of 80 µm or better (Fig. 1d). Rat brain The rat brain is a widely used model for the evaluation of MALDI imaging preparations. The distinct advantage of the coronal brain section as used in this example is the clear left-right symmetry. On top of that, the brain has a wide variety of functionally and anatomically distinct regions, which can be further detailed using molecular marker based histology ( Molecular Histology ). Fig. 2a displays a schematic of major brain regions in the section shown. The different masses selected for molecular imaging in Fig. 2a outline a wide variety of functionally different brain areas. The image resolution in this experiment was 80 µm, sufficient to resolve minute structures such as the granule cell layer of the dentate gyrus (the thin band in the hippocampus visible at mass 6230 Da, arrow in Fig. 2a), which is accurately displayed in the molecular image. Fig 2a shows overlays of different molecular signals simultaneously, underlining the molecular multiplexing analysis capability of MALDI imaging.

Masses indicate different features Cortex Corpus callosum Hippocampal formation Thalamus Hypothalamus Caudoputamen 6551 Da optical image 6713 Da 4963 Da 7542 Da 4938 Da 7843 Da 5433 Da 14092 Da 5764 Da 18358 Da Fig. 2a: Many different brain regions can clearly be associated with specific peptide signals. The image resolution was 80 µm. Scalebar: 5 mm Sample courtesy of Eckhard Friauf, Kaiserslautern, Germany

Detection of structures with 80µm width optical image 18385 Da 6230 Da 7843 Da Fig. 2b: The fine structure (~80 µm thickness) in the hippocampus (arrows) is visualized by m/z 6230. This is perfectly reflected by the molecular image (also compare figure 2a). Overlays of different molecular signals are shown. Scalebar: 5 mm Imaging of mouse kidney cortex medulla pelvis optical H&E stain schematic 3085 Da 4234 Da 4469 Da 4510 Da 4613 Da 5491 Da 6057 Da 8045 Da 9946 Da Fig. 3a: The main, functionally different regions (see schematic) are clearly separated by the molecular signals at 200 µm resolution. Scalebar: 2 mm

Bruker Daltonics is continually improving its products and reserves the right to change specifications without notice. Bruker Daltonics 06-2008, MT-91 Mouse kidney The kidney can be subdivided into three major, functionally different regions: The renal cortex, the renal medulla and the renal pelvis, as seen in the schematic (Fig 3a). In the example shown, a mouse kidney was analyzed with 200 µm image resolution, thus only the main features are resolved. Cortex, medulla and pelvis are clearly distinguishable by molecular markers, and a layered structure becomes apparent inside the cortex. Fig. 3b shows selected masses as multi-colored overlays. Smaller scale features are present in the kidney, such as the glomeruli, but in the mouse these are below 30 µm in diameter and are therefore not resolved in the MALDI image shown. Conclusion The presented data provide insights into state-of-the-art MALDI imaging data quality. Recent crucial improvements in MALDI technology and sample preparation techniques, namely the smartbeam laser technology [1] and the ImagePrep station [2], currently allow the routine generation of high quality MALDI imaging data. An image resolution of 80 µm, as shown here for the epididymis and brain sample, provides good imaging results at reasonable acquisition time in a robust regime, but certainly does not touch the current resolution limits. Protocols and instrumentation enabling image resolution of 30 50 µm are available and even 10 µm seems in reach methods are currently under development at Bruker Daltonics. Multi-color overlay of selected masses Acknowledgements We thank Charles Pineau and Régis Lavigne, University of Rennes, France, for providing the rat testis sample and Eckhard Friauf and Bernd Kaltwaßer, University of Kaiserslautern, for providing the rat brain sample. Authors Michael Becker, Sören-Oliver Deininger, Rene C. Krieg, Martin Schürenberg, Detlev Suckau Bruker Daltonik GmbH, Bremen, Germany References Fig. 3b: Cortex, medulla and pelvis are clearly separated at 200 µm image resolution by the molecular signals shown. Scalebar: 2 mm [1] Holle, A., Haase, A., Kayser, M. & Hoehndorf, J. Optimizing UV laser focus profiles for improved MALDI performance. J. Mass Spectrom. 41, 705 716 (2006). [2] Bruker Daltonics Technical Note-18 ImagePrep Keywords Molecular Histology Instrumentation & Software ImagePrep autoflex III fleximaging For research use only. Not for use in diagnostic procedures. www.bdal.com Bruker Daltonik GmbH Bremen Germany Phone +49 (421) 2205-0 Fax +49 (421) 2205-103 sales@bdal.de Bruker Daltonics Inc. Billerica, MA USA Phone +1 (978) 663-3660 Fax +1 (978) 667-5993 ms-sales@bdal.com