Volume Quantification of 123I-DaTSCAN Imaging by MatLab for the Differentiation and Grading of Parkinsonism and Essential Tremor

Size: px
Start display at page:

Download "Volume Quantification of 123I-DaTSCAN Imaging by MatLab for the Differentiation and Grading of Parkinsonism and Essential Tremor"

Transcription

1 Volume Quantification of 123I-DaTSCAN Imaging by MatLab for the Differentiation and Grading of Parkinsonism and Essential Tremor Maria Lyra, John Striligas, Maria Gavrilleli, Nefeli Lagopati Radiation Physics Unit, A Radiology Department National & Kapodistrian University of Athens, Athens, Greece (Hellas), mlyra@med.uoa.gr Abstract 123I-DaTSCAN imaging studies have shown the ability to detect loss of striatal dopamine transporters. Aim of this work is to evaluate whether mathematical approach of striatum imaging data by Matlab program processing can differentiate between parkinsonian syndromes, of various stages, and essential tremor, and thus increase diagnostic accuracy. The extraction of parameters by digitized processing of 123I-DaTSCAN (123I-ioflupane) images to differentiate between parkinsonism and essential tremor and evaluation of SPECT imaging of the dopamine transporters (DAT) in vivo, will produce a display of pattern recognition. Eccentricity, major & minor axis length, orientation, area, equivalent diameter and integral intensity of both left & right ganglia were determined. A specific ratio of both ganglia parameters gives a classification indication and contributes in diagnosis decision. Keywords DaTSCAN; MatLab image processing; volume quantification; Parkinsomism; striatum I. INTRODUCTION 123I-DaTSCAN (123Ioflupane) is a cocaine analogue that binds to presynaptic dopamine. The dopamine transporter (DAT) is a plasma membrane protein expressed exclusively in dopamine neurons. Imaging of dopamine transporters, situated in the membrane of dopaminergic neurons could detect degeneration of the dopaminergic nigrostriatal pathway [1]. 123I-DaTSCAN imaging studies have shown the ability to detect loss of striatal dopamine transporters. A correct diagnosis of Parkinson s disease (PD) is dependent upon clinical interpretation of the characteristic asymmetrical Parkinsonism responsive to anti-parkinson therapy; there is no specific diagnostic test or biomarker. Clinical distinction of PD from essential tremor (ET) is sometimes difficult due to indefinite parkinsonian features or atypical presentation of PD such as with postural tremor. In ET the occurrence of asymmetry, rest tremor, or other isolated parkinsonian features may contribute to diagnostic doubt. Misdiagnosis is more likely by non specialists than by movement disorder experts. In post-mortem series, atypical parkinsonian syndromes (e.g. multiple system atrophy, progressive supra-nuclear palsy or cortico-basal degeneration) accounted for half of such misdiagnoses [2]-[3]. Abnormal DAT imaging among subjects with olfactory deficit or rapid eye movement sleep disorder, who later develop motor features of PD, suggests that the technique is sensitive even in the pre-motor phase. DAT imaging accurately differentiates between established PD and ET when clinical criteria are fulfilled [4]. It must be noticed that there is variability in size of striatum ~15%; caudate is fatter than putamen and specific uptake ratio decreases with age. Published studies in earlier disease are more limited, in particular regarding blinded imaging analysis and duration of follow-up [5]. The requirement to set a specific volume cut-off threshold is problematic due to the wide overlap between the two diseases, presumably resulting from the individual variation in absolute striatal size. Quantification of DAT single photon emission tomography (SPECT) imaging is suitable for discriminating Parkinsonian syndromes from ET movement disorder, facilitating an early diagnosis of the disease, following up the progression of the disease and assessing the effects of treatment strategies [6]. To objectively assess striatal DAT binding, quantification is mandatory. Nevertheless, the different degradations that are involved in the reconstruction process affect the quantification output. Thus, image /10/$ IEEE 163

2 degrading effects such as attenuation, the spatially variant point spread function scatter and the partial volume effect have to be compensated to achieve an accurate quantification [7]-[9]. In the 123 I decay scheme, there are a few high-energy photons that have a non-negligible contribution to the final image. The effect of this high-energy contamination has to be compensated to improve the image quality and quantification. Generally, partial volume effect causes an underestimation of activity. This effect is especially severe in small structures such as the basal ganglia [10]. To contribute to the differentiation of PD and ET we have extracted special parameters of the images for the characterization of ganglia by differences in morphology as well as in function. Measure properties of the SPECT images regions are calculated by an algorithm in Matlab. Our algorithm calculates shape measurements (Eccentricity, major & minor axis length, orientation, area, equivalent diameter) and pixel measurements (min, max, mean and integral Intensity). Reference [11] has presented a similar algorithm in the IEEE, 2009 International Conference on Advances in Recent Technologies in Communication and Computing. They extracted area, major and minor axis length, eccentricity, orientation, equiv diameter, solidity and perimeter from MR images for segmentation of brain tumours. II. METHOD 123I-DaTSCAN imaging studies have shown the ability to detect loss of striatal dopamine transporters. It has been suggested that the ratio of tracer accumulation in the putamen to that in the caudate nucleus may allow parkinsonian syndromes progression to be assessed [5]. Caudate nucleus and putamen -arise from the same mass of cells- complete the neo striatum or striatum. The head of the caudate nucleus appears to be continuous with the anterior part of the putamen. In SPECT imaging it is difficult to accurately discriminate to two above mentioned structures. By our work no attempt is tried to define the putamen image from that of caudate nucleus. We, on the contrary, estimate the morphofunctional differences of the left and right sub-region of striatum in order to obtain indications on differential diagnosis between PD and ET. A. Patients DaTscan imaging was completed in 2 groups of patients. Group 1 was consisted of 14 patients, with a diagnosis of Parkinsonism in various stages and group 2, included 8 patients with a diagnosis of ET. The study subjects received 400 mg of potassium perchlorate 1 hour before injection of tracer and 200 mg 12 and 24 hours after injection in order to reduce 123 I uptake in their thyroid gland. All patients (group 1 and group 2) were scanned during an 18-months period. 148 MBq DaTscan were injected intravenously. To minimise the potential for pain at the injection site during administration, a slow intravenous injection (15-20 seconds) was completed. The radioligand for striatal dopamine transporter imaging were supplied by GE Healthcare. Then, SPECT acquisition studies were performed. B. Data Acquisition Imaging of the 22 patients (group 1 and group 2) was completed by GE Starcam Brain neurotransmission SPECT imaging with 123 I was performed with low energy high resolution (LEHR) parallel collimator. Total radiation exposure effective dose- to the study subjects was 9 12 msv. The subjects were scanned 4 hours post injection (at peak time of the specific activity of 123I-DaTSCAN). Data were acquired with a full 360 o rotation (120 views for 40sec each) in a 128x128 matrix mode. Radius of rotation was 14 cm. Images were acquired in a step and shoot mode. The energy window (20%) was centred on 159 kev. The pixel size is made up from a combination of field of view, matrix size and zoom factor and it was 3.2mm. Unprocessed projection data were reviewed in cinematic display, prior to reconstruction, to assess the presence and degree of motion and other potential artefacts, in order to exclude (remove) angular projection data in a possible patient motion. C. Data Processing The GE Xeleris-2 image processing system was used to reconstruct angular projections data. Transaxial, sagittal and coronal slices were reconstructed using the filtered back-projection (FBP) technique (Butterworth: order of 8.0 and a cut-off frequency 0.75 cm 1). Chang s attenuation correction was applied (uniform attenuation coefficient of 0.12 cm 1 ). Scatter correction was not applied because of the fact that most radioactivity was expected to be concentrated into the striatum. The imaging resolution was 8 mm. Coronal slices were visually surveyed and the slices were consecutively summarized to the total slice thickness of 3.2 mm and four of them, on the level of the highest striatal radioactivity, were used for region of interest analysis (fig.1). In group of ET subjects, no degeneration signs were found scintigraphically (Fig.1) Figure 1. Series of central 123I-DaTSCAN SPECT imaging slices of ET subject. DATSCAN uptake is highest in middle slices of Striatum. 4 of them, on the level of the highest striatal radioactivity, were summarized for region of interest analysis. Degeneration of the nigrostriatal pathway was found scintigraphically in the first group (Fig.2). 164

3 Figure I-DaTSCAN SPECT imaging central slice of a PD subjects of group 1. Loss in uniformity and increased background and inhomogeneity are remarked in the image. Background intensity isocontours defines the threshold of the striatum specifically in each case (Fig.3). For the slices delineation a histogram technique for the lower threshold was used. A threshold for each patient was defined as the 60% of the maximum striatal count density. Figure 3. Isocontouring on central coronal slice. a) a PD subject with high eccentricity difference between the left and right sub region of the striatum b) low eccentricity difference of the 2 sub-regions in a ET subject. We have transferred the dicom images in a PC (2GHz dual core CPU, 2GB RAM) and saved in an uncompressed bitmap format. Images were processed by Interactive Data Language (IDL) tools for the creation of iso-intensity contours and determine threshold (Fig.3). The slices were processed using the Matlab (The Mathworks, Inc.) development system. The program was written using Matlab s scripting language and graphical user interface (GUI) developer. We have analyzed the SPECT coronal slices data producing a magnified striatum image in the dicom format file (fig.4). Quantification was undertaken by creating the mesh figures over the whole striatum (caudate nucleus, putamen). Mesh figure represents the Intensity Volume of the two regions of striatum (fig.5a, fig.6a, fig.7a). The images were executed in less than a 30 seconds including the pre-processing time. The proposed algorithm takes only 20 second to process the single image slice to create mesh plot and calculate the parameters. Figure 4. Magnified striatum images were obtained for processing, segmentation and data collection by Matlab. Major axis length, areas and integral intensity differences are calculated for the ET and PD subjects. The proposed algorithm was tested using the software MatLabR2010b with images of different views (transverse and coronal views) and of matrix sizes ( , 256x256). Then, parameters calculations of striatum right and left sub-regions (Fig.4) were extracted. Calculated factors for left and right part of the basic ganglia were area, major and minor axis, eccentricity, orientation, equivalent diameter and integral intensity and were used for evaluation. Area is defined as the actual number of pixels in the region. It is used in the algorithm with the integral intensity for comparison as a percentage difference. Major Axis Length defines the length (in pixels) of the major axis of the ellipse that has the same normalized second central moments as the region. The shorter the major axis length is the greater defect of dopamine transporters, an indication of positive PD. Minor Axis Length is the length (in pixels) of the minor axis of the ellipse that has the same normalized second central moments as the region. Eccentricity specifies the eccentricity of the ellipse that has the same second-moments as the region. The eccentricity is the ratio of the distance between the foci of the ellipse and its major axis length. The value is between 0 and 1. 0 and 1 are degenerate cases; an ellipse whose eccentricity is 0 is actually a circle, while an ellipse whose eccentricity is 1 is a line segment. Eccentricity higher of 0.5 was calculated in slices of subjects diagnosed as PD. Orientation is the angle (in degrees ranging from -90 to 90 degrees) between the x-axis and the major axis of the ellipse that has the same second-moments as the region. High declination of the two sub regions in degrees is a feature in PD slices. Equivalent Diameter is the definition of the diameter of a circle with the same area as the region. It is used for the calculation of the equivalent sphere volume of each sub region of the striatum and the estimation of their dopamine transporters volume difference. Background intensity, on the image, plays a crucial role both in visual and quantitative diagnostic evaluation. 165

4 Mean background counts is a weighting factor for the extraction of the final classification index. The smallest sub-region is consistent with the size of imaging resolution (_0.8 cm_0.8 cm_0.8 cm). The volume of the striatum is 6 7 cm 3 in healthy controls. Each subregion of interest is the left or right part of the striatum. The total number of counts in these sub-regions was defined by the ratio of integral intensity per area of each striatum part. From the mean number of counts (counts/voxel) in each sub-region, the observed relative dispersion was calculated. This relative dispersion was used as a measure of the heterogeneity of regional striatal DAT density at each sub-region. The observed dispersions of the striatal tracer distributions were also calculated. The difference of major as well as minor axis length of the 2 striatum sub-regions was calculated as a percentage and is an indication of the striatum DAT transporters positions deformation. Orientation and eccentricity differences were calculated to give factors that characterize dispersion of DAT transporters to abnormal positions. III. RESULTS Iso-intensities Ellipse areas were created all around the striatum to create the mesh plot (Fig.5a, Fig.6a and Fig.7a). Data were extracted and Area, Eccentricity, major & minor axis length, Orientation, equivalent Diameter and Integral Intensity of both left & right ganglia were calculated (Fig.5b, Fig.6b, and Fig.7b) Loss in uniformity-mesh plotting distribution is used for grades extraction. The difference of intensity volume percentage of Mesh plotting of the striatum sub-regions images gives a semi quantitative index. Quantitative profile indices were extracted and ratios of specific binding were calculated of the images of left and right part of the striatum. These indices are calculated for both PD subjects and for ET diagnosed subjects. Specific binding ratio is lower in PD than in ET subjects. Striatal uptake ratios were graded up to 4 abnormal levels. The results of the proposed algorithm are gained by a parametric combination of each sub-region coronal slice and a correlation of the two sub-regions of the stratum gives final diagnostic factor for each patient. These factors of the striatum of PD and ET subjects are summarized and a range of (4,8+/-3,9) expresses PD grade while ET indices cover the (0,9+/-0,4) range. Figure 5. a) Intensity of dopamine receptors area is plotted in mesh plot. Processing by our algorithm gives the Intensity distribution and b) useful parameters of each sub-region of striatum are calculated for classification 166

5 2010 CSSR 2010 Initial Submission Figure 7. a) Mesh plotting of the striatum image similar indices of intensities over areas for both sub regions. b) Values of Eccentricity, major & minor axis length, Orientation, equivalent Diameter for both left & right ganglia were determined to be close for this ET subject. Figure 6. a) Subject 6. Loss in volume intensity is indicated in Mesh plotting distribution. Volume intensity difference as a percentage gives the abnormality of the striatum. b) Segmentation parameters were extracted. Differences of major and minor axis as percentage, eccentricity and orientation of the 2 sub regions, give diagnostic factors values for a PD subject. IV. DISCUSSION & CONCLUSION Semi-quantitative analysis of striatum mesh figures and caudate/putamen intensities (uptake) were consistent with the results of visual inspection and clinical diagnosis. Matlab processing and analysis of 123I-DaTSCAN images can contribute to the differentiation between essential tremor and Parkinsonism, especially in early staged Parkinson's disease. These days, detection of basic ganglia function and the exact location and orientation has become an extremely important task in the differential diagnosis of Parkinson Disease than that of Essential Tremor. Detection of striatum function and structure (relative to Dopamine Transporters) plays an important role in the planning and analysis of various treatments and follow up of Parkinson diseases. Because of this, development of efficient and accurate DaTSCAN image segmentation techniques has become an important area of research today, in neurology. Via IDL & Matlab program we integrated an array oriented language and a graphical display technique by profiles of the regions of interest data. Quantitative factors were extracted and ratios of specific binding were calculated of the striatum imaging of all subjects (PD & ET) and correlated. 167

6 Striatal uptake ratios were graded up to 4 levels. Group of ET subjects covered the 1 grade and intersect to abnormal grade 2. Our results show that quantitative analysis of Datscan images provides an objective way to extract and interpret image data. We have presented a method to differentiate PD diagnosis from ET diagnosis. The algorithm developed measure parameters from 123I-DatSCAN SPECT images that are characteristic for each patient and we can classify to two groups of PD and ET. Segmentation method gives striatum regions property functions using image processing toolbox. The parameters extracted are area, major and minor axis length, eccentricity, orientation, equivalent diameter and integral intensity for each striatum sub region. This method is quite versatile, fast and simple to use. Quantitative processing of 123I-DaTSCAN images is a useful diagnostic test in the differential diagnosis of tremor disorders. Semi-quantitative analysis of specific binding uptake was consistent with the results of visual inspection and clinical diagnosis. Studies have further demonstrated that, automated observant-independent software in DAT imaging adds to diagnostic accuracy in patients with suspected PD at the earliest stages of illness [12]. Reliable, rapid, easy-toadminister automated tools for quantitative analysis of DAT images would potentially improve diagnostic accuracy and enable more effective, widespread use of DAT imaging technology in clinical practice [13]. Other investigators have published a comparison of different methods of DatSCAN quantification by analyzing the relative SPECT imaging [14]. It is important to indicate that literature suggests an association between ET and PD. The risk of incident PD has been quantified in cases of ET [15]. Patients with ET were four times more likely than controls to develop incident PD during prospective follow-up. These data confirm and begin to quantify the link between these two diseases. The performance of a pattern recognition program can also aid to detect Parkinsonism in early stage. The proposed technique used for PD and ET differential diagnosis, can also be applied to other applications in nuclear medical imaging of small organs as thyroid gland for texture evaluation or in paediatric nuclear nephrology imaging using the parameters calculated by this algorithm to determine left and right kidney parenchyma situation. ACKNOWLEDGMENT All authors are thankful to the personnel of Medical Imaging Center in Athens for their assistance in acquiring the patients imaging data. REFERENCES [1] DaTSCAN, PDS information sheet FS4, 48, Parkinson;s Disease Society, 2001 [2] E. Tolosa, G. Wenning, W. Poewe, The diagnosis of Parkinson s disease, Lancet Neurol., Vol. 5, pp , 2006 [3] V.L. Marshall, C. B. Reininger, M. Marquardt, J.Patterson, D.M. Hadley, W.H. Oertel et al, Parkinson s disease is overdiagnosed clinically at baseline in diagnostically uncertain cases: A 3-year European multicenter study with repeat [123I]FP- CIT SPECT, Movement Disorders, Vol. 24, No. 4, pp , 2009 [4] A. Hughes, S.E. Daniel, L Kilford, A.J. Lees, Accuracy of clinical diagnosis of idiopathic Parkinson s disease: a clinicopathological study of 100 cases, J Neurol Neurosurg Psychiatry, vol.55, pp , 1992 [5] H.Y. Shin, S.Y. Kang, J.H. Yang,, H.S. Kim, M.S. Lee, and Y.H. Sohn, Use of the Putamen/Caudate Volume Ratio for Early Differentiation between Parkinsonian Variant of Multiple System Atrophy and Parkinson Disease, Journal of Clinical Neurology, Vol. 3, pp79-81, June 2007 [6] C. Crespo, J. Gallego, A. Cot, C. Falcón, S. Bullich, D. Pareto et al, Quantification of dopaminergic neurotransmission SPECT studies with 123I-labelled radioligands. A comparison between different imaging systems and data acquisition protocols using Monte Carlo simulation, Eur J Nucl Med Mol Imaging, Vol.35, pp , 2008, DOI /s z [7] A.Paschali, L. Messinis, O. Kargiotis, V. Lakiotis, Z. Kefalopoulou, C. Constantoyannis et al SPECT neuroimaging and neuropsychological functions in different stages of Parkinson s disease Eur J Nucl Med Mol Imaging Vol.37, pp: , 2010, DOI /s [8] F. Doepp, M. Plotkin, L.Siegel, A. Kivi, D.Gruber, E. Lobsien, et al, Brain Parenchyma Sonography and 123I-FP-CIT SPECT in Parkinson s Disease and Essential Tremor Movement Disorders, Vol. 23, No. 3, 2008, pp [9] Castellano, L. Bonilha, L.M. Li, F. Cendes Texture analysis of medical images Clinical Radiology, Vol. 59, pp , 2004 [10] K. Van Laere, C. Casteels, L. De Ceuninck, B. Vanbilloen, A. Maes, L. Mortelmans et al Dual-tracer dopamine transporter and perfusion SPECT in differential diagnosis of Parkinsonism Using template-based discriminant analysis, J Nucl Med, Vol.47, pp , [11] L. Singh, R.B. Dubey, Z.A. Jaffery, Segmentation and Characterization of Brain Tumor from MR Images, Advances in Recent Technologies in Communication and Computing, IEEE Computer Society International conference, pp , 2009, /ARTCom [12] W. Koch, P. Radau, C. Hamann, K. Tatsch, Clinical testing of an optimized software solution for an automated, observerindependent evaluation of dopamine transporter SPECT studies, J Nucl Med., Vol.46, pp , 2005 [13] R. Buchert, G.Berding, F.Wilke, IBZM tool: a fully automated expert system for the evaluation of IBZM SPECT studies, Eur J Nucl Med Mol Imaging, Vol.33, pp , 2006 [14] R.J. Morton, M.J. Guy, R. Clauss, P.J. Hinton, C.A. Marshall, E.A. Clarke, Comparison of different methods of DatSCAN quantification, Nucl Med Commun. Vol.26, pp , 2005 [15] J. Benito-León, E.D Louis, F. Bermejo-Pareja, Risk of incident Parkinson s disease and Parkinsonism in essential tremor: a population based study, J Neurol Neurosurg Psychiatry, Vol.80, pp , 2009, doi: /jnnp

Impact of CT based attenuation correction on quantitative assessment of DaTSCAN ( 123 I-Ioflupane) imaging in diagnosis of extrapyramidal diseases

Impact of CT based attenuation correction on quantitative assessment of DaTSCAN ( 123 I-Ioflupane) imaging in diagnosis of extrapyramidal diseases Nuclear Medicine Review 2008 Vol. 11, No. 2, pp. 53 58 Copyright 2008 Via Medica ISSN 1506 9680 Impact of CT based attenuation correction on quantitative assessment of DaTSCAN ( 123 I-Ioflupane) imaging

More information

Corporate Medical Policy

Corporate Medical Policy Corporate Medical Policy Dopamine Transporter Imaging with Single Photon Emission File Name: Origination: Last CAP Review: Next CAP Review: Last Review: dopamine_transporter_imaging_with_single_photon_emission_computed_tomography

More information

Optimized, Automated Striatal Uptake Analysis Applied to SPECT Brain Scans of Parkinson s Disease Patients

Optimized, Automated Striatal Uptake Analysis Applied to SPECT Brain Scans of Parkinson s Disease Patients Optimized, Automated Striatal Uptake Analysis Applied to SPECT Brain Scans of Parkinson s Disease Patients I. George Zubal, Michele Early, Olive Yuan, Danna Jennings, Kenneth Marek, and John P. Seibyl

More information

Views and Reviews. [ 123 I]FP-CIT (DaTscan) SPECT Brain Imaging in Patients with Suspected Parkinsonian Syndromes ABSTRACT

Views and Reviews. [ 123 I]FP-CIT (DaTscan) SPECT Brain Imaging in Patients with Suspected Parkinsonian Syndromes ABSTRACT Views and Reviews [ 123 I]FP-CIT (DaTscan) SPECT Brain Imaging in Patients with Suspected Parkinsonian Syndromes Robert A. Hauser, MD, Donald G. Grosset, MD From the Departments of Neurology, Molecular

More information

Dopamine Transporter Imaging with Single Photon Emission Computed Tomography

Dopamine Transporter Imaging with Single Photon Emission Computed Tomography Last Review Status/Date: September 2014 Page: 1 of 14 Photon Emission Computed Tomography Description Dopamine transporter imaging with single photon emission computed tomography (DAT-SPECT) is being evaluated

More information

SPECT Dopamin Transporter lmaging Agent

SPECT Dopamin Transporter lmaging Agent SPECT Dopamin Transporter lmaging Agent Product Summary Product Name DATrace-123 Injection Active Ingredient Action Mechanism DATrace-123 is used as a radiopharmaceutical for the SPECT imaging of Dopamine

More information

I-123 SPECT: task groups

I-123 SPECT: task groups I-123 SPECT: task groups Literature Review: Seibyl Claim Formulation Clinical Image Acquisition & Processing: Dewaraja Phantoms/ DRO: Dickson & Zimmerman Quantitative & Image Analysis: Seibyl & Miyaoka

More information

Transcranial sonography in movement disorders

Transcranial sonography in movement disorders Transcranial sonography in movement disorders Uwe Walter 1st Residential Training of the European Society of Neurosonology and Cerebral Hemodynamics September 7-12, 2008 Bertinoro, Italy Department of

More information

Imaging biomarkers for Parkinson s disease

Imaging biomarkers for Parkinson s disease 3 rd Congress of the European Academy of Neurology Amsterdam, The Netherlands, June 24 27, 2017 Teaching Course 6 MDS-ES/EAN: Neuroimaging in movement disorders - Level 2 Imaging biomarkers for Parkinson

More information

GE Healthcare. Protocol Manual. Abnormal Scan. Normal Scan. Period-Shaped. Comma-Shaped

GE Healthcare. Protocol Manual. Abnormal Scan. Normal Scan. Period-Shaped. Comma-Shaped GE Healthcare Protocol Manual Normal Scan Comma-Shaped Abnormal Scan Period-Shaped 1 Contents Section 1: Introduction... 4 1.1 Scope 1.2 What is DaTscan? Section 2: Image Acquisition, Interpretation, and

More information

POLICY PRODUCT VARIATIONS DESCRIPTION/BACKGROUND RATIONALE DEFINITIONS BENEFIT VARIATIONS DISCLAIMER CODING INFORMATION REFERENCES POLICY HISTORY

POLICY PRODUCT VARIATIONS DESCRIPTION/BACKGROUND RATIONALE DEFINITIONS BENEFIT VARIATIONS DISCLAIMER CODING INFORMATION REFERENCES POLICY HISTORY Original Issue Date (Created): July 30, 2013 Most Recent Review Date (Revised): May 20, 2014 Effective Date: August 1, 2014 POLICY PRODUCT VARIATIONS DESCRIPTION/BACKGROUND RATIONALE DEFINITIONS BENEFIT

More information

Short communication. dwk&:key words: Parkinson s disease Single-photon emission tomography Dopamine transporter imaging Aging. Materials and methods

Short communication. dwk&:key words: Parkinson s disease Single-photon emission tomography Dopamine transporter imaging Aging. Materials and methods Short communication [ 123 I]β-CIT single-photon emission tomography in Parkinson s disease reveals a smaller decline in dopamine transporters with age than in controls G. Tissingh 1, P. Bergmans 1, J.

More information

Clinical evaluation of [ 123 I]FP-CIT SPECT scans on the novel brain-dedicated InSPira HD SPECT system: a head-to-head comparison

Clinical evaluation of [ 123 I]FP-CIT SPECT scans on the novel brain-dedicated InSPira HD SPECT system: a head-to-head comparison Adriaanse et al. EJNMMI Research (2018) 8:85 https://doi.org/10.1186/s13550-018-0436-y SHORT COMMUNICATION Clinical evaluation of [ 123 I]FP-CIT SPECT scans on the novel brain-dedicated InSPira HD SPECT

More information

Introduction, use of imaging and current guidelines. John O Brien Professor of Old Age Psychiatry University of Cambridge

Introduction, use of imaging and current guidelines. John O Brien Professor of Old Age Psychiatry University of Cambridge Introduction, use of imaging and current guidelines John O Brien Professor of Old Age Psychiatry University of Cambridge Why do we undertake brain imaging in AD and other dementias? Exclude other causes

More information

A Snapshot on Nuclear Cardiac Imaging

A Snapshot on Nuclear Cardiac Imaging Editorial A Snapshot on Nuclear Cardiac Imaging Khalil, M. Department of Physics, Faculty of Science, Helwan University. There is no doubt that nuclear medicine scanning devices are essential tool in the

More information

FEP Medical Policy Manual

FEP Medical Policy Manual FEP Medical Policy Manual Effective Date: January 15, 2018 Related Policies: 6.01.06 Miscellaneous (Noncardiac, Nononcologic) Applications of Positron Emission Tomography 6.01.55 β-amyloid Imaging With

More information

Application of 3D Printing to Molecular Radiotherapy Phantoms. Nick Calvert Nuclear Medicine Group The Christie NHS Foundation Trust, Manchester

Application of 3D Printing to Molecular Radiotherapy Phantoms. Nick Calvert Nuclear Medicine Group The Christie NHS Foundation Trust, Manchester Application of 3D Printing to Molecular Radiotherapy Phantoms Nick Calvert Nuclear Medicine Group The Christie NHS Foundation Trust, Manchester Molecular Radiotherapy Radionuclide administered to patient

More information

GE Healthcare. Protocol Manual. Abnormal Scan. Normal Scan. Period-Shaped. Comma-Shaped

GE Healthcare. Protocol Manual. Abnormal Scan. Normal Scan. Period-Shaped. Comma-Shaped GE Healthcare Protocol Manual Normal Scan Comma-Shaped Abnormal Scan Period-Shaped Contents Section 1: Introduction... 4 1.1 Scope 1.2 What is DaTscan? Section 2: Image Acquisition, Interpretation, and

More information

Application of Pattern Recognition Framework for Quantification of Parkinson s Disease in DAT SPECT Imaging

Application of Pattern Recognition Framework for Quantification of Parkinson s Disease in DAT SPECT Imaging Application of Pattern Recognition Framework for Quantification of Parkinson s Disease in DAT SPECT Imaging Saurabh Jain, Yousef Salimpour, Laurent Younes, Gwenn Smith, Zoltan Mari, Vesna Sossi, Arman

More information

Photon Attenuation Correction in Misregistered Cardiac PET/CT

Photon Attenuation Correction in Misregistered Cardiac PET/CT Photon Attenuation Correction in Misregistered Cardiac PET/CT A. Martinez-Möller 1,2, N. Navab 2, M. Schwaiger 1, S. G. Nekolla 1 1 Nuklearmedizinische Klinik der TU München 2 Computer Assisted Medical

More information

Dopamine Transporter Imaging With Single-Photon Emission Computed. Tomography

Dopamine Transporter Imaging With Single-Photon Emission Computed. Tomography Dopamine Transporter Imaging With Single-Photon Emission Computed Tomography Policy Number: 6.01.54 Last Review: 9/2017 Origination: 9/2015 Next Review: 9/2018 Policy Blue Cross and Blue Shield of Kansas

More information

Creation and validation of an I-123 FP-CIT template for statistical image analysis using high-resolution SPECT for parkinsonian patients

Creation and validation of an I-123 FP-CIT template for statistical image analysis using high-resolution SPECT for parkinsonian patients Ann Nucl Med (2016) 30:477 483 DOI 10.1007/s12149-016-1085-8 ORIGINAL ARTICLE Creation and validation of an I- FP-CIT template for statistical image analysis using high-resolution SPECT for parkinsonian

More information

years; baseline off-state Unified Parkinson s Disease Rating Scale (UPDRS) motor ratings 24.6 ± 6.8).

years; baseline off-state Unified Parkinson s Disease Rating Scale (UPDRS) motor ratings 24.6 ± 6.8). Jourdain et al. 1 Supplemental Data Supplemental Methods Subjects We studied 28 PD subjects (20 men and 8 women; age 61.0 ± 9.6 (mean ± SD) years; duration 8.7 ± 9.6 years; baseline off-state Unified Parkinson

More information

Clinical Study Serotonin Transporter Availability in Early Stage Parkinson s Disease and Multiple System Atrophy

Clinical Study Serotonin Transporter Availability in Early Stage Parkinson s Disease and Multiple System Atrophy ISRN Neurology, Article ID 345132, 4 pages http://dx.doi.org/10.1155/2014/345132 Clinical Study Serotonin Transporter Availability in Early Stage Parkinson s Disease and Multiple System Atrophy S. R. Suwijn,

More information

The Parkinson s You Can t See

The Parkinson s You Can t See The Parkinson s You Can t See We principally see the motor phenomena of Parkinson's disease, but is there an early stage without visible features? Might this provide a window for disease-modifying therapy?

More information

DIFFERENTIAL DIAGNOSIS SARAH MARRINAN

DIFFERENTIAL DIAGNOSIS SARAH MARRINAN Parkinson s Academy Registrar Masterclass Sheffield DIFFERENTIAL DIAGNOSIS SARAH MARRINAN 17 th September 2014 Objectives Importance of age in diagnosis Diagnostic challenges Brain Bank criteria Differential

More information

Imaging of the dopaminergic system with SPECT has

Imaging of the dopaminergic system with SPECT has Clinical Testing of an Optimized Software Solution for an Automated, Observer-Independent Evaluation of Dopamine Transporter SPECT Studies Walter Koch, MD 1 ; Perry E. Radau, PhD 2 ; Christine Hamann,

More information

PET in Radiation Therapy. Outline. Tumor Segmentation in PET and in Multimodality Images for Radiation Therapy. 1. Tumor segmentation in PET

PET in Radiation Therapy. Outline. Tumor Segmentation in PET and in Multimodality Images for Radiation Therapy. 1. Tumor segmentation in PET Tumor Segmentation in PET and in Multimodality Images for Radiation Therapy Wei Lu, Ph.D. Department of Radiation Oncology Mallinckrodt Institute of Radiology Washington University in St. Louis Outline

More information

Draft agreed by Scientific Advice Working Party 26 October Adopted by CHMP for release for consultation 09 November

Draft agreed by Scientific Advice Working Party 26 October Adopted by CHMP for release for consultation 09 November 29 May 2018 EMA/CHMP/SAWP/765041/2017 Committee for Medicinal Products for Human Use (CHMP) Qualification opinion on dopamine transporter imaging as an enrichment biomarker for Parkinson s disease clinical

More information

Brain neurotransmission SPECT is currently devoted

Brain neurotransmission SPECT is currently devoted Quantitative Accuracy of Dopaminergic Neurotransmission Imaging with I SPECT Marine Soret, MSc 1 ; Pierre Malick Koulibaly, PhD 2 ; Jacques Darcourt, MD, PhD 2 ;Sébastien Hapdey, PhD 1 ; and Irène Buvat,

More information

Update on functional brain imaging in Movement Disorders

Update on functional brain imaging in Movement Disorders Update on functional brain imaging in Movement Disorders Mario Masellis, MSc, MD, FRCPC, PhD Assistant Professor & Clinician-Scientist Sunnybrook Health Sciences Centre University of Toronto 53 rd CNSF

More information

Dopamine Transporter Imaging With Single-Photon Emission Computed. Tomography

Dopamine Transporter Imaging With Single-Photon Emission Computed. Tomography Dopamine Transporter Imaging With Single-Photon Emission Computed Tomography Policy Number: 6.01.54 Last Review: 9/2018 Origination: 9/2015 Next Review: 9/2019 Policy Blue Cross and Blue Shield of Kansas

More information

Calculation methods in Hermes Medical Solutions dosimetry software

Calculation methods in Hermes Medical Solutions dosimetry software Calculation methods in Hermes Medical Solutions dosimetry software Helena McMeekin MSc. Clinical Applications Scientist, Hermes Medical Solutions MRTDosimetry Scientific Workshop The Principals and Clinical

More information

Quantitative and Qualitative Evaluations of Defect Images in Different Regions of Myocardial Phantom under Implementation of Various Filters in SPECT

Quantitative and Qualitative Evaluations of Defect Images in Different Regions of Myocardial Phantom under Implementation of Various Filters in SPECT Indian Journal of Science and Technology, Vol 8(12), DOI: 10.17485/ijst/2015/v8i12/31943, June 2015 ISSN (Print) : 0974-6846 ISSN (Online) : 0974-5645 Quantitative and Qualitative Evaluations of Defect

More information

Round table: Moderator; Fereshteh Sedaghat, MD, PhD Brain Mapping in Dementias and Non-invasive Neurostimulation

Round table: Moderator; Fereshteh Sedaghat, MD, PhD Brain Mapping in Dementias and Non-invasive Neurostimulation Round table: Moderator; Fereshteh Sedaghat, MD, PhD Brain Mapping in Dementias and Non-invasive Neurostimulation 1. Reflection of Mild Cognitive Impairment (MCI) and Dementias by Molecular Imaging, PET

More information

Kinematic Modeling in Parkinson s Disease

Kinematic Modeling in Parkinson s Disease Kinematic Modeling in Parkinson s Disease Alexander Hui Department of Bioengineering University of California, San Diego La Jolla, CA 92093 alexhui@ucsd.edu Abstract Parkinson s disease is a slowly progressing

More information

Background. New Cross Hospital is a 700 bed DGH located in central England

Background. New Cross Hospital is a 700 bed DGH located in central England Background New Cross Hospital is a 700 bed DGH located in central England Regional Heart & Lung centre opened in 2005 Covering the Black Country (Population >1,000,000) Nuclear Medicine Department Single

More information

SPECT and PET Imaging: DaT Scan, Cerebral Blood Flow and Epilepsy

SPECT and PET Imaging: DaT Scan, Cerebral Blood Flow and Epilepsy SPECT and PET Imaging: DaT Scan, Cerebral Blood Flow and Epilepsy Dana Mathews Ph.D. M.D. Division of Nuclear Medicine Department of Radiology The University of Texas Southwestern Medical Center Financial

More information

Ultralow Dose Chest CT with MBIR

Ultralow Dose Chest CT with MBIR Ultralow Dose Chest CT with MBIR Ella A. Kazerooni, M.D. Professor & Director Cardiothoracic Radiology Associate Chair for Clinical Affairs University of Michigan Disclosures Consultant: GE Healthcare

More information

Dopamine transporter imaging 123 I-FP-CIT (DaTSCAN) SPET in differential diagnosis of dopa-responsive dystonia and young-onset Parkinson s disease

Dopamine transporter imaging 123 I-FP-CIT (DaTSCAN) SPET in differential diagnosis of dopa-responsive dystonia and young-onset Parkinson s disease Dopamine transporter imaging I-FP-CIT (DaTSCAN) SPET in differential diagnosis of dopa-responsive dystonia and young-onset Parkinson s disease Leposava D. Brajkovic 1 MD Marina V. Svetel 2, MD, PhD Vladimir

More information

QIBA Profile: Quantifying Dopamine Transporters with 123 Iodine Labeled Ioflupane in Neurodegenerative Diseases

QIBA Profile: Quantifying Dopamine Transporters with 123 Iodine Labeled Ioflupane in Neurodegenerative Diseases 5 QIBA Profile: Quantifying Dopamine Transporters with 123 Iodine Labeled Ioflupane in Neurodegenerative Diseases (Short Title: SPECT dopamine transporters) 10 Stage: Version 1.1 for Conformance Testing

More information

UvA-DARE (Digital Academic Repository) SPECT imaging in young patients with schizophrenia Lavalaye, J. Link to publication

UvA-DARE (Digital Academic Repository) SPECT imaging in young patients with schizophrenia Lavalaye, J. Link to publication UvA-DARE (Digital Academic Repository) SPECT imaging in young patients with schizophrenia Lavalaye, J. Link to publication Citation for published version (APA): Lavalaye, J. (2001). SPECT imaging in young

More information

Radiation Detection and Measurement

Radiation Detection and Measurement Radiation Detection and Measurement Range of charged particles (e.g.,!: µm; ": mm) Range of high energy photons (cm) Two main types of interactions of high energy photons Compton scatter Photoelectric

More information

Truncation in Myocardial Perfusion SPECT Imaging

Truncation in Myocardial Perfusion SPECT Imaging International Journal of Nuclear Energy Scie nce and Engineering Vol. 2 Iss. 4, December 2012 Truncation in Myocardial Perfusion SPECT Imaging Brian Wosnitzer *, Marvin Friedman, Gordon DePuey Division

More information

Draft agreed by Scientific Advice Working Party 26 October Adopted by CHMP for release for consultation 09 November

Draft agreed by Scientific Advice Working Party 26 October Adopted by CHMP for release for consultation 09 November 1 2 3 20 November 2017 EMA/765041/2017 Product Development Scientific Support Department 4 Draft qualification opinion on molecular neuroimaging of 5 the dopamine transporter as biomarker to identify 6

More information

Evaluation of Parkinson s Patients and Primary Care Providers

Evaluation of Parkinson s Patients and Primary Care Providers Evaluation of Parkinson s Patients and Primary Care Providers 2018 Movement Disorders Half Day Symposium Elise Anderson MD Medical Co-Director, PBSI Movement Disorders 6/28/2018 1 Disclosures GE Speaker,

More information

Dual-isotope imaging ( 123 I/ 99m Tc) has potential clinical

Dual-isotope imaging ( 123 I/ 99m Tc) has potential clinical Absolute Activity Quantitation in Simultaneous I/ Tc Brain SPECT Georges El Fakhri, Stephen C. Moore, Philippe Maksud, André Aurengo, and Marie Foley Kijewski Department of Radiology, Harvard Medical School

More information

University of Groningen. Quantitative CT myocardial perfusion Pelgrim, Gert

University of Groningen. Quantitative CT myocardial perfusion Pelgrim, Gert University of Groningen Quantitative CT myocardial perfusion Pelgrim, Gert IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check

More information

Early Detection of Lung Cancer

Early Detection of Lung Cancer Early Detection of Lung Cancer Aswathy N Iyer Dept Of Electronics And Communication Engineering Lymie Jose Dept Of Electronics And Communication Engineering Anumol Thomas Dept Of Electronics And Communication

More information

Dopamine Transporter Imaging With Single-Photon Emission Computed Tomography

Dopamine Transporter Imaging With Single-Photon Emission Computed Tomography Dopamine Transporter Imaging With Single-Photon Emission Computed Tomography Applies to all products administered or underwritten by Blue Cross and Blue Shield of Louisiana and its subsidiary, HMO Louisiana,

More information

3D ultrasound applied to abdominal aortic aneurysm: preliminary evaluation of diameter measurement accuracy

3D ultrasound applied to abdominal aortic aneurysm: preliminary evaluation of diameter measurement accuracy 3D ultrasound applied to abdominal aortic aneurysm: preliminary evaluation of diameter measurement accuracy Poster No.: C-0493 Congress: ECR 2011 Type: Authors: Keywords: DOI: Scientific Paper A. LONG

More information

Basal ganglia motor circuit

Basal ganglia motor circuit Parkinson s Disease Basal ganglia motor circuit 1 Direct pathway (gas pedal) 2 Indirect pathway (brake) To release or augment the tonic inhibition of GPi on thalamus Direct pathway There is a tonic inhibition

More information

MPI Overview. Artifacts and Pitfalls in MPI. Acquisition and Processing. Peeyush Bhargava MD, MBA

MPI Overview. Artifacts and Pitfalls in MPI. Acquisition and Processing. Peeyush Bhargava MD, MBA Artifacts and Pitfalls in MPI MPI Overview Peeyush Bhargava MD, MBA www.nuclearmd.com ~ 40% of all Nuclear Medicine Procedures ~ 9 million procedures every year in US >95% are SPECT,

More information

Learnings from Parkinson s disease: Critical role of Biomarkers in successful drug development

Learnings from Parkinson s disease: Critical role of Biomarkers in successful drug development Learnings from Parkinson s disease: Critical role of Biomarkers in successful drug development Ken Marek Coalition Against Major Diseases and FDA 2014 Annual Scientific Workshop Oct 2014 Disclosure Co-founder

More information

Austin Radiological Association Nuclear Medicine Procedure WHITE BLOOD CELL MIGRATION STUDY (In-111-WBCs, Tc-99m-HMPAO-WBCs)

Austin Radiological Association Nuclear Medicine Procedure WHITE BLOOD CELL MIGRATION STUDY (In-111-WBCs, Tc-99m-HMPAO-WBCs) Austin Radiological Association Nuclear Medicine Procedure WHITE BLOOD CELL MIGRATION STUDY (In-111-WBCs, Tc-99m-HMPAO-WBCs) Overview Indications The White Blood Cell Migration Study demonstrates the distribution

More information

Brain imaging for the diagnosis of people with suspected dementia

Brain imaging for the diagnosis of people with suspected dementia Why do we undertake brain imaging in dementia? Brain imaging for the diagnosis of people with suspected dementia Not just because guidelines tell us to! Exclude other causes for dementia Help confirm diagnosis

More information

Accuracy of SPECT bone scintigraphy in diagnosis of meniscal tears ABSTRACT

Accuracy of SPECT bone scintigraphy in diagnosis of meniscal tears ABSTRACT 1 Iran J Nucl Med 2005; 23 Accuracy of SPECT bone scintigraphy in diagnosis of meniscal tears M. Saghari 1, M. Moslehi 1, J. Esmaeili 2, M.N. Tahmasebi 3, A. Radmehr 4, M. Eftekhari 1,2, A. Fard-Esfahani

More information

SPECT or PET for Cardiovascular Screening in High-Risk Patients

SPECT or PET for Cardiovascular Screening in High-Risk Patients SPECT or PET for Cardiovascular Screening in High-Risk Patients Paeng, Jin Chul MD PhD Department of Nuclear Medicine Seoul National University Hospital Contents Recent Development in SPECT and PET Technology

More information

Austin Radiological Association Nuclear Medicine Procedure PET SODIUM FLUORIDE BONE SCAN (F-18 NaF)

Austin Radiological Association Nuclear Medicine Procedure PET SODIUM FLUORIDE BONE SCAN (F-18 NaF) Austin Radiological Association Nuclear Medicine Procedure PET SODIUM FLUORIDE BONE SCAN (F-18 NaF) Overview Indication Sodium Fluoride F18 injection is a radioactive diagnostic agent for positron emission

More information

Austin Radiological Association BRAIN AMYLOID STUDY (F-18-Florbetapir)

Austin Radiological Association BRAIN AMYLOID STUDY (F-18-Florbetapir) Austin Radiological Association BRAIN AMYLOID STUDY (F-18-Florbetapir) Overview The Brain Amyloid Study with F-18-florbetapir depicts the extracellular deposition of B- amyloid (Aβ) peptides (or plaques

More information

A Comparison of Strategies for Summing Gated Myocardial Perfusion SPECT: Are False Negatives a Potential Problem?

A Comparison of Strategies for Summing Gated Myocardial Perfusion SPECT: Are False Negatives a Potential Problem? ISPUB.COM The Internet Journal of Cardiology Volume 4 Number 1 A Comparison of Strategies for Summing Gated Myocardial Perfusion SPECT: Are False Negatives a Potential Problem? J Wheat, G Currie Citation

More information

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method

Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method Iran. J. Radiat. Res., 2004; 1(4): 187-194 Measurement of organ dose in abdomen-pelvis CT exam as a function of ma, KV and scanner type by Monte Carlo method M.R. Ay 1, M. Shahriari 2, S. Sarkar 3, P.

More information

Extraction of Blood Vessels and Recognition of Bifurcation Points in Retinal Fundus Image

Extraction of Blood Vessels and Recognition of Bifurcation Points in Retinal Fundus Image International Journal of Research Studies in Science, Engineering and Technology Volume 1, Issue 5, August 2014, PP 1-7 ISSN 2349-4751 (Print) & ISSN 2349-476X (Online) Extraction of Blood Vessels and

More information

NIH Public Access Author Manuscript Proc SPIE. Author manuscript; available in PMC 2014 February 07.

NIH Public Access Author Manuscript Proc SPIE. Author manuscript; available in PMC 2014 February 07. NIH Public Access Author Manuscript Published in final edited form as: Proc SPIE. 2007 March 5; 6512: 651236. doi:10.1117/12.708950. Semi-Automatic Parcellation of the Corpus Striatum Ramsey Al-Hakim a,

More information

CT Optimisation for Paediatric SPECT/CT Examinations. Sarah Bell

CT Optimisation for Paediatric SPECT/CT Examinations. Sarah Bell CT Optimisation for Paediatric SPECT/CT Examinations Sarah Bell Sarah.bell14@nhs.net Outline 1. Introduction 2. Aims and Objectives 3. Methods 4. Results 5. Discussion 6. Conclusions 7. References Introduction

More information

Dose Calibration for DaTscan

Dose Calibration for DaTscan GE Healthcare Dose Calibration for DaTscan Please review the simple steps below to learn how to properly calibrate your dose of DaTscan. 1 2 3 4 5 6 7 8 9 Reading DaTscan in the Dose Calibrator 1. Place

More information

Evaluating the roles of the basal ganglia and the cerebellum in time perception

Evaluating the roles of the basal ganglia and the cerebellum in time perception Sundeep Teki Evaluating the roles of the basal ganglia and the cerebellum in time perception Auditory Cognition Group Wellcome Trust Centre for Neuroimaging SENSORY CORTEX SMA/PRE-SMA HIPPOCAMPUS BASAL

More information

Imaging in epilepsy: Ictal perfusion SPECT and SISCOM

Imaging in epilepsy: Ictal perfusion SPECT and SISCOM Imaging in epilepsy: Ictal perfusion SPECT and SISCOM Patrick Dupont Laboratory for Cognitive Neurology Laboratory for Epilepsy Research Medical Imaging Research Center KU Leuven, Belgium E-mail: Patrick.Dupont@med.kuleuven.be

More information

Medical Physics 4 I3 Radiation in Medicine

Medical Physics 4 I3 Radiation in Medicine Name: Date: 1. This question is about radiation dosimetry. Medical Physics 4 I3 Radiation in Medicine Define exposure. A patient is injected with a gamma ray emitter. The radiation from the source creates

More information

Modifi ed CT perfusion contrast injection protocols for improved CBF quantifi cation with lower temporal sampling

Modifi ed CT perfusion contrast injection protocols for improved CBF quantifi cation with lower temporal sampling Investigations and research Modifi ed CT perfusion contrast injection protocols for improved CBF quantifi cation with lower temporal sampling J. Wang Z. Ying V. Yao L. Ciancibello S. Premraj S. Pohlman

More information

Diagnostic Accuracy of Parkinson Disease by Support Vector Machine (SVM) Analysis of 123 I-FP-CIT Brain SPECT Data

Diagnostic Accuracy of Parkinson Disease by Support Vector Machine (SVM) Analysis of 123 I-FP-CIT Brain SPECT Data Diagnostic Accuracy of Parkinson Disease by Support Vector Machine (SVM) Analysis of 123 I-FP-CIT Brain SPECT Data Implications of Putaminal Findings and Age Barbara Palumbo, MD, Mario Luca Fravolini,

More information

Research Article Pre- and Postsynaptic Dopamine SPECT in Idiopathic Parkinsonian Diseases: A Follow-Up Study

Research Article Pre- and Postsynaptic Dopamine SPECT in Idiopathic Parkinsonian Diseases: A Follow-Up Study BioMed Research International Volume 2013, Article ID 143532, 14 pages http://dx.doi.org/10.1155/2013/143532 Research Article Pre- and Postsynaptic Dopamine SPECT in Idiopathic Parkinsonian Diseases: A

More information

ORIGINAL CONTRIBUTION

ORIGINAL CONTRIBUTION ORIGINAL CONTRIBUTION Common Misdiagnosis of a Common Neurological Disorder How Are We Misdiagnosing Essential Tremor? Samay Jain, MD; Steven E. Lo, MD; Elan D. Louis, MD, MS Background: As a common neurological

More information

Reproducibility of Uptake Estimates in FDG PET: a Monte Carlo study

Reproducibility of Uptake Estimates in FDG PET: a Monte Carlo study Reproducibility of Uptake Estimates in FDG PET: a Monte Carlo study Juliette Feuardent, Marine Soret, Irène Buvat 1 Abstract Tumor glucose metabolism measurements from Fluoro-deoxyglucose (FDG) Positron

More information

Modified Fractal Analysis of Brain PET and SPECT to Assess Grey and White Matter Function

Modified Fractal Analysis of Brain PET and SPECT to Assess Grey and White Matter Function Modified Fractal Analysis of Brain PET and SPECT to Assess Grey and White Matter Function Harold T. Pretorius, M.D., Ph.D., ^Jerome J. Kelly, M.D.,^ Gwen Hubbell M.D.,^ Claire Hubbell M.D., M.B.A.,^ Ellen

More information

COMPUTERIZED SYSTEM DESIGN FOR THE DETECTION AND DIAGNOSIS OF LUNG NODULES IN CT IMAGES 1

COMPUTERIZED SYSTEM DESIGN FOR THE DETECTION AND DIAGNOSIS OF LUNG NODULES IN CT IMAGES 1 ISSN 258-8739 3 st August 28, Volume 3, Issue 2, JSEIS, CAOMEI Copyright 26-28 COMPUTERIZED SYSTEM DESIGN FOR THE DETECTION AND DIAGNOSIS OF LUNG NODULES IN CT IMAGES ALI ABDRHMAN UKASHA, 2 EMHMED SAAID

More information

Il ruolo di nuove tecniche di imaging per la diagnosi precoce di demenza

Il ruolo di nuove tecniche di imaging per la diagnosi precoce di demenza Parma, 23 maggio 2017 Il ruolo di nuove tecniche di imaging per la diagnosi precoce di demenza Livia Ruffini SC Medicina Nucleare Azienda Ospedaliero-Universitaria di Parma PET AND SPECT STUDIES OF THE

More information

Shape Modeling of the Corpus Callosum for Neuroimaging Studies of the Brain (Part I) Dongqing Chen, Ph.D.

Shape Modeling of the Corpus Callosum for Neuroimaging Studies of the Brain (Part I) Dongqing Chen, Ph.D. The University of Louisville CVIP Lab Shape Modeling of the Corpus Callosum for Neuroimaging Studies of the Brain (Part I) Dongqing Chen, Ph.D. Computer Vision & Image Processing (CVIP) Laboratory Department

More information

MRI Image Processing Operations for Brain Tumor Detection

MRI Image Processing Operations for Brain Tumor Detection MRI Image Processing Operations for Brain Tumor Detection Prof. M.M. Bulhe 1, Shubhashini Pathak 2, Karan Parekh 3, Abhishek Jha 4 1Assistant Professor, Dept. of Electronics and Telecommunications Engineering,

More information

Preview of Presentation

Preview of Presentation Preview of Presentation Discuss Healthcare Environment Clinical Implementation of Technical Innovations SNMMI/ASNC Joint Statement on Rb-82 Cardiac PET Imaging Protocol Principles of Rb-82 Cardiac Imaging

More information

FDG-PET e parkinsonismi

FDG-PET e parkinsonismi Parkinsonismi FDG-PET e parkinsonismi Valentina Berti Dipartimento di Scienze Biomediche, Sperimentali e Cliniche Sez. Medicina Nucleare Università degli Studi di Firenze History 140 PubMed: FDG AND parkinsonism

More information

COGNITIVE IMPAIRMENT IN PARKINSON S DISEASE

COGNITIVE IMPAIRMENT IN PARKINSON S DISEASE 1 GENERAL INTRODUCTION GENERAL INTRODUCTION PARKINSON S DISEASE Parkinson s disease (PD) is a neurodegenerative movement disorder, named after James Parkinson who described some of its characteristic

More information

Austin Radiological Association Ga-68 NETSPOT (Ga-68 dotatate)

Austin Radiological Association Ga-68 NETSPOT (Ga-68 dotatate) Austin Radiological Association Ga-68 NETSPOT (Ga-68 dotatate) Overview Ga-68 dotatate binds to somatostatin receptors, with highest affinity for subtype 2 receptors (sstr2). It binds to cells that express

More information

Biases affecting tumor uptake measurements in FDG-PET

Biases affecting tumor uptake measurements in FDG-PET Biases affecting tumor uptake measurements in FDG-PET M. Soret, C. Riddell, S. Hapdey, and I. Buvat Abstract-- The influence of tumor diameter, tumor-tobackground activity ratio, attenuation, spatial resolution,

More information

8/10/2016. PET/CT Radiomics for Tumor. Anatomic Tumor Response Assessment in CT or MRI. Metabolic Tumor Response Assessment in FDG-PET

8/10/2016. PET/CT Radiomics for Tumor. Anatomic Tumor Response Assessment in CT or MRI. Metabolic Tumor Response Assessment in FDG-PET PET/CT Radiomics for Tumor Response Evaluation August 1, 2016 Wei Lu, PhD Department of Medical Physics www.mskcc.org Department of Radiation Oncology www.umaryland.edu Anatomic Tumor Response Assessment

More information

Parkinsonism or Parkinson s Disease I. Symptoms: Main disorder of movement. Named after, an English physician who described the then known, in 1817.

Parkinsonism or Parkinson s Disease I. Symptoms: Main disorder of movement. Named after, an English physician who described the then known, in 1817. Parkinsonism or Parkinson s Disease I. Symptoms: Main disorder of movement. Named after, an English physician who described the then known, in 1817. Four (4) hallmark clinical signs: 1) Tremor: (Note -

More information

TWO HANDED SIGN LANGUAGE RECOGNITION SYSTEM USING IMAGE PROCESSING

TWO HANDED SIGN LANGUAGE RECOGNITION SYSTEM USING IMAGE PROCESSING 134 TWO HANDED SIGN LANGUAGE RECOGNITION SYSTEM USING IMAGE PROCESSING H.F.S.M.Fonseka 1, J.T.Jonathan 2, P.Sabeshan 3 and M.B.Dissanayaka 4 1 Department of Electrical And Electronic Engineering, Faculty

More information

Nuclear neurology. Zámbó Katalin Department of Nuclear Medicine

Nuclear neurology. Zámbó Katalin Department of Nuclear Medicine Nuclear neurology Zámbó Katalin Department of Nuclear Medicine To refresh your memory Brain has a high rate of oxidative metabolism. It has no reserves either of oxygen or of glucose and has a very limited

More information

Visualization strategies for major white matter tracts identified by diffusion tensor imaging for intraoperative use

Visualization strategies for major white matter tracts identified by diffusion tensor imaging for intraoperative use International Congress Series 1281 (2005) 793 797 www.ics-elsevier.com Visualization strategies for major white matter tracts identified by diffusion tensor imaging for intraoperative use Ch. Nimsky a,b,

More information

Faezeh Vedaei 1, 2, Alireza Kamali asl 1, Faraz Kalantari 3,4,, Mohammad Reza Ay

Faezeh Vedaei 1, 2, Alireza Kamali asl 1, Faraz Kalantari 3,4,, Mohammad Reza Ay Assessment of the impact of applying attenuation correction on the accuracy of activity recovery in Tc99m-ECD brain SPECT of healthy subject using Statistical Parametric Mapping (SPM) Faezeh Vedaei 1,

More information

T he main symptoms of idiopathic Parkinson s disease

T he main symptoms of idiopathic Parkinson s disease 1211 PAPER How useful is [ 123 I]b-CIT SPECT in clinical practice? J Eerola, P J Tienari, S Kaakkola, P Nikkinen, J Launes... See end of article for authors affiliations... Correspondence to: Dr Johanna

More information

Differential Diagnosis of Hypokinetic Movement Disorders

Differential Diagnosis of Hypokinetic Movement Disorders Differential Diagnosis of Hypokinetic Movement Disorders Dr Donald Grosset Consultant Neurologist - Honorary Professor Institute of Neurological Sciences - Glasgow University Hypokinetic Parkinson's Disease

More information

Estimation of Breast Density and Feature Extraction of Mammographic Images

Estimation of Breast Density and Feature Extraction of Mammographic Images IJIRST International Journal for Innovative Research in Science & Technology Volume 2 Issue 11 April 2016 ISSN (online): 2349-6010 Estimation of Breast Density and Feature Extraction of Mammographic Images

More information

CALCULATION of the CEREBRAL HEMORRHAGE VOLUME USING ANALYSIS of COMPUTED TOMOGRAPHY IMAGE

CALCULATION of the CEREBRAL HEMORRHAGE VOLUME USING ANALYSIS of COMPUTED TOMOGRAPHY IMAGE CALCULATION of the CEREBRAL HEMORRHAGE VOLUME USING ANALYSIS of COMPUTED TOMOGRAPHY IMAGE Cory Amelia* Magister of Physics, Faculty of Science and Mathematics, Diponegoro University, Semarang, Indonesia

More information

Impaired Regional Myocardial Function Detection Using the Standard Inter-Segmental Integration SINE Wave Curve On Magnetic Resonance Imaging

Impaired Regional Myocardial Function Detection Using the Standard Inter-Segmental Integration SINE Wave Curve On Magnetic Resonance Imaging Original Article Impaired Regional Myocardial Function Detection Using the Standard Inter-Segmental Integration Ngam-Maung B, RT email : chaothawee@yahoo.com Busakol Ngam-Maung, RT 1 Lertlak Chaothawee,

More information

responsiveness HMPAO SPECT in Parkinson's disease before and after levodopa: correlation with dopaminergic (SSmTc HMPAO) as a tracer in 21 patients

responsiveness HMPAO SPECT in Parkinson's disease before and after levodopa: correlation with dopaminergic (SSmTc HMPAO) as a tracer in 21 patients 18 1ournal of Neurology, Neurosurgery, and Psychiatry 1994;57:18-185 Department of Neurology H S Markus A J Lees Institute of Nuclear Medicine, University College and Middlesex School of Medicine, London,

More information

Simulations of Preclinical andclinical Scans in Emission Tomography, Transmission Tomography and Radiation Therapy. Using GATE

Simulations of Preclinical andclinical Scans in Emission Tomography, Transmission Tomography and Radiation Therapy. Using GATE GATE Simulations of Preclinical andclinical Scans in Emission Tomography, Transmission Tomography and Radiation Therapy Using GATE Quick tour & Highlights! GATE Training, INSTN-Saclay, October 2015 Albertine

More information

A comparative study of machine learning methods for lung diseases diagnosis by computerized digital imaging'"

A comparative study of machine learning methods for lung diseases diagnosis by computerized digital imaging' A comparative study of machine learning methods for lung diseases diagnosis by computerized digital imaging'" Suk Ho Kang**. Youngjoo Lee*** Aostract I\.' New Work to be 1 Introduction Presented U Mater~al

More information

Supplementary Online Content

Supplementary Online Content Supplementary Online Content Jauhar S, Nour MM, Veronese M, et al. A test of the transdiagnostic dopamine hypothesis of psychosis using positron emission tomographic imaging in bipolar affective disorder

More information