Hamilton Syringes. LT N LTN RN TLL TLL with slots. Hamilton Syringe Types Microliter. Hamilton Point Styles

Size: px
Start display at page:

Download "Hamilton Syringes. LT N LTN RN TLL TLL with slots. Hamilton Syringe Types Microliter. Hamilton Point Styles"

Transcription

1 Hamilton LT N LTN RN TLL TLL with slots Hamilton Point Styles Pt. 2 Pt. 3 Pt. 5 Pt. HP Hamilton syringes are designed as precision measuring instruments, and find wide use for sample introduction into analytical instruments, as well as volume dispensers for accurate, small-scale dilutions. Hamilton Syringe Types Microliter - For use with liquids. It has an individually-fitted stainless steel plunger. Modified Microliter - For micro-sampling liquids, the entire sample is contained in the needle. A tungsten-wire plunger travels the length of the needle to displace the sample. Gastight - This features a precision PTFE plunger tip, for use with both gases and liquids. Syringe Terminations N RN TLL LT Hamilton Point Styles Point Style 2 - For septa penetration and GC injections Point Style 3 - For pipetting and HPLC injections Point Style 5 - Used to minimize septum coring Point Style HP - Used on Agilent 7673 / 1683 Autosamplers Syringe Terminations N, Cemented Needle - Needles are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. Not autoclavable. RN, Removable Needle - Removable needles seat precisely to the zero graduation mark of the syringe; damaged needles are easily replaced. Autoclavable when disassembled. TLL, PTFE Luer Lock - The male luer taper accepts all luer-hub needles and connectors; locks luer hubs in place. Autoclavable when disassembled. LT, Luer Tip - Ground glass syringe barrel with a male luer taper accepts most hypodermic needles. Autoclavable when disassembled. LTN, Luer Tip Cemented Needle - Needles are cemented into the glass syringe barrel at a point corresponding to the zero graduation mark. Not autoclavable. KH, Knurled Hub - The knurled hub, with replaceable needle, is used on 7000 series syringes only. Autoclavable when disassembled. The knurled hub enables high injection pressures and attachment of spacers, for repeatable-depth injections. LTN KH 108 Chromatography Research Supplies, Inc.

2 Hamilton Digital Syringe The only N.I.S.T. traceable, calibrated syringe device available Easy-to-read LCD displays volume dispensed within +/- 0.5% of the syringe volume Used with Hamilton syringes with total volumes of 0.5 to 500 µl Comes with certificates of analysis CRS offers the Hamilton Digital Syringe, for unsurpassed accuracy and precision. With the Digital Syringe, problems of plunger tip positioning and consistency are eliminated. Note: The handle can be used with any existing syringe of the types listed. However, it is only N.I.S.T. traceable with the serialized syringe that comes with it when ordered. Digital Syringe Microliter Digital Model Volume Gauge Length Pt. 2 Pt. 3 N- Cemented Needle 75 5 µl 26s 2 / 51 mm DS µl 26s 2 / 51 mm DS80300 DS µl 22s 2 / 51 mm DS µl 22s 2 / 51 mm DS80400 DS µl 22s 2 / 51 mm DS80500 DS µl 22s 2 / 51 mm DS80600 DS µl 22s 2 / 51 mm DS80700 DS µl 22 2 / 51 mm DS80800 DS80865 RN- Removable Needle 75 5 ul 26s 2 / 51 mm DS ul 26s 2 / 51 mm DS ul 22s 2 / 51 mm ul 22s 2 / 51 mm DS ul 22s 2 / 51 mm DS ul 22s 2 / 51 mm DS ul 22s 2 / 51 mm DS ul 22 2 / 51 mm DS80830 Gastight Digital Model Volume Gauge Length Pt. 2 Pt. 3 N- Cemented Needle µl 26s 2 / 51 mm DS80000 DS µl 22s 2 / 51 mm DS80200 DS µl 22s 2 / 51 mm DS80900 DS µl 22s 2 / 51 mm DS81000 DS µl 22s 2 / 51 mm DS81100 DS µl 22 2 / 51 mm DS81217* RN- Removable Needle µl 26s 2 / 51 mm DS µl 22s 2 / 51 mm DS µl 22s 2 / 51 mm DS µl 22s 2 / 51 mm DS µl 22s 2 / 51 mm DS µl 22 2 / 51 mm DS81230 *Cemented luer-tip needle (LTN)

3 Hamilton Microliter Microliter - This is the standard syringe for use with liquids. It has a stainless steel plunger individually fitted to the barrel. Microliter 700 Series - The standard Microliter syringe SM Explanation of Codes 5 µl 10 µl 25 µl 50 µl 100 µl 250 µl 500 µl Codes Model: N RN LT PT N- 6 pack RN- 6 pack Gauge/Length/Point 26s/2/2 26s/2/2 22s/2/2 22s/2/2 22s/2/2s 22s/2/2 22/2/2 N RN LT 600 Series - The compact Microliter syringe 2.5 µl 5 µl Codes Model: RN Gauge/Length/Point 22s/2/3 22s/2/3 KH Pt Series - The Microliter syringe with a handle and replaceable parts SM 5 µl 10 µl 25 µl 50 µl 100 µl 250 µl Codes Model: N RN Gauge/Length/Point 26s/2/2 26s/2/2 22s/2/2 22s/2/2 22s/2/2s 22s/2/2 Note: s with a gauge designates narrow-bore. For complete replacement needle listing, see page Chromatography Research Supplies, Inc.

4 Hamilton Microliter Hamilton Microliter, from left to right; 700, 800, 900 and 7000 series. 900 Series - The economical Microliter syringe with a handle SM 5 µl 10 µl Codes Model: N RN Gauge/Length/Point 26s/2/2 26s/2/ Series - The Modified Microliter syringe with the sample in the needle SM 0.5 µl 1 µl 1 µl 2 µl 2 µl 5 µl Codes Model: KH Gauge/Length/Point 25s/2.75/2 25s/2.75/2 22s/2.75/2 25s/2.75/2 23s/2.75/2s 24/2.75/2 Note: s with the gauge designates narrow-bore. Chaney (Reproducibility) Adapters For consistent, reproducible injections Prevents syringe plunger bending Adjustable stop prevents plunger damage Easily installed For 700, 1700 and 7000 series Chaney Adapters For 700, 1700; 10 µl For 700 above 10 µl; For 1700; µl For 800, For For 800, 900 and 1800 series Guide Assembly Prevents syringe plunger bending Adjustable stop prevents plunger damage Easily installed Guide Assembly For 700, 5 µl and 10 µl; For 700, 1700; above 10 µl For 7000 Series

5 Hamilton Gastight Gastight - This type of syringe features a precision-machined PTFE plunger tip, for use with both gas and liquid samples. N RN LT 1700 Series - The standard Gastight syringe SM 10 µl 25 µl 50 µl 100 µl 250 µl 500 µl Codes Model: N RN LT TLL Gauge/Length/Point 26s/2/2 22s/2/2 22s/2/2 22s/2/2 22s/2/2s 22/2/2 KH LTN TLL PT Series - The Gastight syringe with a handle and replaceable parts SM 10 µl 25 µl 50 µl 100 µl 250 µl Codes Model: N RN Gauge/Length/Point 26s/2/2 22s/2/2 22s/2/2 22s/2/2s 22s/2/2 Note: s with a gauge designates narrow-bore. For complete replacement needle listing, see page 112 Chromatography Research Supplies, Inc.

6 Hamilton Gastight 1000 Series - The high performance Gastight syringe SM 1 ml 1.25 ml 2.5 ml 5 ml 10 ml Codes Model: RN LT LTN TLL LTNPT Gauge/Length/Point 22/2/2 22/2/2 22/2/2 22/2/2 22/2/ Series, ml - The high performance Gastight syringe 25 ml 50 ml 100 ml Codes Model: TLL Super For air sampling, preparing gas standards, calibrating reservoirs PTFE luer lock termination for many applications Acrylic plastic barrel Hamilton Company s Super will handle your big jobs. These are suitable for many measuring and sampling applications in the lab and field. The PTFE luer lock fitting takes standard luer-hub needles (needles not included). Please note the acrylic barrel is not suitable for use with solvents. Volume SO L S L S L S L Super Syringe 113

7 Hamilton SampleLock Lock your sample in the SampleLock syringe with the easy-to-use twist valve Inject internal standards through the valve port into samples contained in the SampleLock syringe Pressurize gaseous samples prior to GC injection Prevent loss of sample and plunger blowout at elevated pressures with the positive rear plunger stop SampleLock SampleLock syringes allow you to collect, store, transport, and analyze liquid or gaseous samples without the danger of evaporative loss or environmental contamination. Common applications for SampleLock syringes include environmental sample collection and storage, pre-pressurization of gaseous samples for GC analyses, and sample spiking. The SampleLock syringe combines the quality of the world-renowned Hamilton Gastight syringe with an easy-to-use twist valve. The syringe is available in sizes ranging from 50 µl to 100 ml. A positive rear stop on the SampleLock syringe (250 µl to 100 ml) prevents plunger blowout and loss of sample. In addition, for improved precision and accuracy, the SampleLock syringes may be used in conjunction with Hamilton Company s new Digital Syringe. SampleLock syringes come with 2, point style 2 RN needles, 22 gauge (except 22s gauge for µl). Valve Operation - The SampleLock valve is easy to use; a simple twist is all it takes to open or close the valve. Open the valve by turning it so that the cap is in line with the fluid path. Close the valve by turning it so that the cap is perpendicular to the fluid path. Purge & Trap Syringe - A purge and trap (P & T) version of the SampleLock syringe is available in 5 ml capacity. It comes with a male luer fitting, and is designed for analysis of drinking water following methods such as EPA 502, 503 and 524. SampleLock Model Volume 1705SL 50 µl SL 100 µl SL 250 µl SL 500 µl SL 1.0 ml SL 2.5 ml SL 5 ml SLPT 5 ml P&T SL 10 ml SL 25 ml SL 50 ml SL 100 ml Chromatography Research Supplies, Inc.

8 Hamilton Specialty GC Syringe Pack This convenient package contains three of the most often needed syringes for GC: 701N (10 µl - standard liquid measuring device); 1702N ( 25 µl - for gas or liquid injections); 7001KH (1 µl - eliminates dead volume). GC Syringe Pack µl Syringe with Stainless Steel Needle For Capillary On-Column Injection Inject small samples directly onto columns (0.25 mm ID and greater) with this fine-diameter needle syringe. Capacity is 0.5 µl. The stainless steel needle has a 0.23 mm OD OC Syringe Spare Needle/Plunger Assembly Fused Silica Needle Syringe For Capillary On-Column Injection Hamilton combines their popular Microliter syringes with a needle made from fused silica (coated with high-temperature polyimide for strength), for direct injection onto your fused silica capillary column. The deactivated fused silica needles and precision syringe hubs and ferrules ensure accurate, reproducible and essentially inert sample handling. The needles are available in various lengths and they can be used with 10 µl Microliter syringes as well as the 10 µl Gastight syringe. Accuracy and reproducibility are within 1% of the syringe volume Fused-Silica Needle 701 RNFS Syringe, 10 µl capillary RNFS Syringe, 10 µl capillary Replacement Parts FS Needle, 10 cm x 0.17 mm OD PTFE Ferrule, 0.17 mm bore diameter Spacer

9 Hamilton GC Autosampler Dual Gauge 23s - 26s (Tapered) Needle for Agilent 7673 / 7683 Autosampler Provides the durability of a 23s gauge needle Ability of a 26s gauge needle to perform split/ splitless and on-column injections Model/ Capacity Gauge Microliter - The syringe without the PTFE-tipped plungers 700 Series Cemented Needle Syringe 5 µl 23s - 26s µl 23s - 26s Series Removable Needle Syringe 5 µl 23s - 26s µl 23s - 26s Gastight - The syringe with the PTFE-tipped plungers 1700 Series Cemented Needle Syringe 5 µl 23s - 26s µl 23s - 26s Series Removable Needle Syringe 5 µl 23s - 26s µl 23s - 26s Dual-Gauge Syringe Six-Packs for Agilent 7673A Cemented needle Storage container provided 23s - 26s Gauge Qty 5 µl Microliter 6/pk µl Gastight 6/pk µl Microliter 6/pk µl Gastight 6/pk for PerkinElmer Autosystem TM GC OD / Length / Pt. Style 5 µl 0.47 mm / / µl 0.63 mm / / , Chromatography Research Supplies, Inc.

10 Hamilton GC Autosampler Single Gauge Needle for Agilent 7673 / 7683 Autosampler Gauge 700 Series Cemented Needle Syringe Microliter 5 µl 23s µl 26s µl 23s µl 26s Series Removable Needle Syringe Microliter 5 µl 23s µl 26s µl 23s µl 26s Series Removable Needle Syringe Gastight 10 µl 23s µl 26s Replacement Needles, 6/pk, for Microliter or Gastight 23s s Single Gauge Syringe Six-Packs Agilent 7673 / 83 Cemented needle Microliter Storage container provided Capacity Gauge Qty 5 µl 23s 6/pk µl 26s 6/pk µl 23s 6/pk µl 26s 6/pk for Agilent 7670A, 7671A, 7672A Model / Capacity 700 Series Syringe, 26s Gauge 10 µl Cemented Needle µl Removable Needle Series Syringe, 26s Gauge 10 µl Cemented Needle µl Removable Needle Series Syringe, 25s Gauge 1 µl Knurled Hub Syringe Six-Pack for Agilent 7670A, 7671A, 7672A Syringe; Six 10 µl Hamilton 700 Series Microliter cemented needles Hamilton 700 Series Microliter syringe 117

11 Hamilton HPLC Autosampler for Waters WISP Autosampler 1700 Series Gastight 25 µl µl Priming Syringe for Waters Use for priming Waters HPLC pumps 501, 510, 610, 610E, 6000, 6000A Use for sampling with PrepLC 500A LCs Priming Syringe Rheodyne, Altrex, Valco VISF-2 Injectors 2 length OD Point style 3, no taper Model / Capacity Gauge 600 Series Removable Needle 2.5 µl 22s µl 22s Series Cemented Needle 10 µl 22s µl 22s µl 22s µl 22s µl µl Series Removable Needle 10 µl 22s µl 22s µl 22s µl 22s µl µl Removable Needle RN Style Capacity Gauge Qty For Rheodyne, Alex, Valco VISF-2 Injectors µl 22s 6/pk ml 22 6/pk For Valco VISF-1 Injectors µl 22s 6/pk ml 22 6/pk Chromatography Research Supplies, Inc.

12 Hamilton HPLC Autosampler and Carbon Analyzer for PerkinElmer - For series 200 Autosampler Capacity 1705CX 50 µl CX 250 µl CX 500 µl C 1.0 ml C 2.5 ml for Shimadzu - For SIL6A Autosampler Capacity 1710RN without Needle 100 µl for Themo Instruments Capacity For Autosampler models SP8780 / SP8875 / SP C 500 µl C 2.5 ml For Autosampler models AS100 / AS300 / AS1000 / AS3000 / AS C 250 µl C 500 µl C 1 ml C 2.5 ml C 5 ml Carbon Analyzer Syringe The Carbon Analyzer Syringe incorporates a special luer tapered hub cemented over a 700 Series syringe. The syringe is used in conjunction with total organic carbon analyzers to monitor waste water and environmentally sensitive water resources. Syringe parts in contact with sample are borosilicate glass, 302 stainless steel plunger and 304 stainless steel needle. Gauge 50 µl, 705CA Syringe µl, 705CA Syringe µl, 710CA Syringe µl, 725CA Syringe Carbon Analyzer Syringe 119

13 Pt. 2 Pt. 3 Pt. 5 Hamilton Needles Point Style 2 - For septa penetration and GC injections; 22 O bevel Point Style 3 - For pipetting and HPLC injections; blunt tip Point Style 5 - Used to minimize septum coring; conical point with side port Removable Needles for RN Style, 6/pk Point Style 2 Point Style 3 Point Style 5 For ul 22 gauge s gauge gauge s gauge For 250 ul - 10 ml 22 gauge s gauge gauge s gauge RN Style Needles Luer Lock Needles for Hamilton LT and TLL, 6/pk These are replacement needles for LT and TLL syringes. They are available with a metal (nickel-plated brass) or fluorocarbon (Kel-F) hub. Needles are made from type 304 stainless steel. Needles are 2 long and have point style 2, 3 or 5. Metal Hub Kel-F Hub OD x ID Metal Metal Metal Kel-F Kel-F Kel-F Gauge mm Point 2 Point 3 Point 5 Point 2 Point 3 Point x s.47 x x x s.71 x x x x Chromatographic Luer Hub Needles, 6/pk Made from 304 stainless steel tubing, 2 long Electrotapered Gauge Metal Hub CTFE Hub 22s s s Chromatography Research Supplies, Inc.

14 Accessories Needle Cleaning Kit This kit is specifically designed for cleaning syringes and needles. It includes one bottle of organic, biodegradable cleaning solution, and 10 each of five different diameter tungsten wires, ranging in diameter from to Suggested cleaning procedures are included. This kit is especially recommended for use with Hamilton needles and syringes. Needle Cleaning Kit Fine Wire Kit The CRS Fine Wire Kit lets you clean many small items around the lab; also useful for bending into microhooks, other uses. The kit contains a pin vise and 30 stainless steel wires, 10 of each of the following sizes: 0.006, and Please note: the wires in this kit cannot be used to clean 26s or 22s gauge needles. Fine Wire Kit Hamilton Syringe Cleaner The Hamilton Syringe Cleaner effectively cleans 7000 Series syringes by vaporizing residues with a combination of high heat (approximately 370 O C) and vacuum (0.1 mm Hg). The syringe needle is inserted through the septum for 30 seconds while the plunger is reciprocated several times. This cleaner is not effective against syringes with plugged needles or frozen plungers. Care should be used when handling because of the extreme temperature generated. The cleaner is available in 120 or 220 volt versions. Syringe Cleaner, 120 V Syringe Cleaner, 220 V

15 VICI Sampling Series A Syringe - Built-in Valve The Series A syringe is supplied with a turn valve for storage of samples at either sub-ambient pressures or elevated pressures to 17 bar (250 psi). The syringe eliminates back-flushing prior to injection because you can pressurize the sample. The Series A syringe contains a positive rear flange plunger stop to prevent blowout of the barrel at elevated pressures. The plunger is made of PTFE for leak tight fit. Series A Syringe 100 µl Series A Syringe µl Series A Syringe µl Series A Syringe ml Series A Syringe ml Series A Syringe ml Series A Syringe ml Series A Syringe Replacement Needles.028 OD x.005 ID, 2.25 Tapered OD x.012 ID, 2.25 Side Port Series A-2 Syringe - Push Button Valve This is one of the handiest syringes available for gas sampling. The Series A-2 features a unique push-button valve that allows sample storage capability in syringes as small as 25 µl. It is also useful for samples with low-boiling components that could be lost through evaporation. The push-button valve allows for pre-pressurizing the samples before injection. The A-2 syringe has very low dead volume due to the special needle and needle connector. Series A-2 Syringe 25 µl Series A-2 Syringe µl Series A-2 Syringe µl Series A-2 Syringe µl Series A-2 Syringe µl Series A-2 Syringe ml Series A-2 Syringe ml Series A-2 Syringe ml Series A-2 Syringe ml Series A-2 Syringe Replacement Needles.028 OD x.005 ID, 2 Bevel up to 100 µl Series A-2 Syringe OD x.012 ID, 2 Bevel up to 100 µl Series A-2 Syringe OD x.012 ID, 2 Side Port for all Series A Chromatography Research Supplies, Inc.

16 VICI Sampling Series C Syringe - without Valve This syringe has all the features of the Series A except the valve. It is useful for everyday in-lab sampling; low-cost. The Series C syringe has a special slip-on needle connector for a lower dead volume than the average luer-style connectors. 100 µl Series C Syringe µl Series C Syringe µl Series C Syringe ml Series C Syringe ml Series C Syringe ml Series C Syringe ml Series C Syringe Series C Syringe Replacement Needles.028 OD x.005 ID, 2.25 Tapered OD x.012 ID, 2.25 Side Port Series D Syringe- Economical The Series D syringe is a high-precision, no frills gas syringe. The syringe has a leak-tight Pressure-Lok plunger tip and no-dead-volume barrel design. 1 ml Series D Syringe ml Series D Syringe Series D Syringe Replacement Needles.028 OD x.005 ID, 2.25 Tapered OD x.012 ID, 2.25 Side Port Pressure-Lok Mini-Injector Injects as little as 0.01 µl. With this syringe you can directly inject small samples without using splitters, for improved reproducibility. The Pressure-Lok Mini-Injector uses a notched plunger within the needle; the fixed sample volume is contained in the notch. A PTFE packing seals the needle and plunger to prevent leakage. Available in two fixed volumes; needle length is 2 3/ µl Syringe µl Syringe

17 VICI Sampling Series CG-130 Syringe - Research Grade The Series CG-130 has a plunger gauged to stop at zero without bottoming out. This aids in stopping the needle from plugging or dislodging and enhances reproducibility. The CG-130 syringe handles gases or liquids and has a self-lubricating PTFE plunger tip. are color coded for identification. Series CG-130 Syringe 5 µl Fixed Needle Syringe µl Fixed Needle Syringe µl Removable Needle Syringe µl Removable Needle Syringe Replacement needles, 3/pk Series C-120 Syringe - Leak-Proof Seal The Series-120 is suitable for general purpose chromatography work. It comes equipped with a PTFE plunger and provides a leak tight seal to 17 bar ( 250 psi). This syringe can be used with liquids or gases. The Series-120 also includes a barrel extension beyond the rear flange, which permits attachment of a vacuum bulb or line for cleaning. Series C-120 Syringe 5 µl Fixed Needle Syringe µl Fixed Needle Syringe µl Fixed Needle Syringe µl Fixed Needle Syringe Series C-160 Syringe - High Quality The C-160 offers reliable performance at an economical price. A plunger tip of stress-formed virgin PTFE is self-lubricating and durable, and the PTFE needle seat at the rear of the needle prevents possible dissolution of the needle cement or contamination of the sample. Pressure rated at 17 bar (250 psi) maximum, gases and liquids. Replacement needles are open end bevel type, sized.019 x.005 x Series C-160 Syringe 5 µl Fixed Needle Syringe µl Fixed Needle Syringe µl Fixed Needle Syringe µl Fixed Needle Syringe µl Removable Needle Syringe µl Removable Needle Syringe µl Removable Needle Syringe µl Removable Needle Syringe Replacement Needles Replacement Needles, 3/pk Chromatography Research Supplies, Inc.

18 VICI Sampling Autosampler For PerkinElmer AS-100/300 and VICI models GC-311 and GC-411 Available for normal (standard) or viscous liquid samples. The viscous syringes use needles with wider IDs. Needle IDs for the standard syringe is.005. Needle IDs for the viscous syringes are listed below. 3 µl Standard Syringe µl Standard Syringe µl Standard Syringe µl Viscous Syringe µl Viscous Syringe µl Viscous Syringe Replacement Needles For 3 µl Standard Syringe For 5 µl Standard Syringe For 10 µl Standard Syringe For 3 µl Standard Syringe, ID For 5 µl Standard Syringe, ID For 10 µl Standard Syringe, ID Autosampler Syringe - For Agilent 7673A The Dynatech syringe for the Agilent 7673 / 7683A has the Pressure-Lok design and a PTFE plunger tip for greater precision and durability. The syringe has 10 µl capacity. 22 gauge, Blunt Needle Syringe gauge, Blunt Needle Syringe gauge, Bevel Needle Syringe

Selecting The Right Syringe

Selecting The Right Syringe Selecting The Right Syringe Choosing the Right Hamilton Syringe for Your Application 1. Is your sample a gas or a liquid? For a gas sample, use a GASTIGHT syringe. GASTIGHT 1000, 1700 and 1800 Series 1000/1700

More information

cataleg-inl-2007-def6.indd /01/ :27:30

cataleg-inl-2007-def6.indd /01/ :27:30 140 cataleg-inl-2007-def6.indd 140 30/01/2009 17:27:30 Index Syringes Hamilton Syringes Content Page Content Page Hamilton General Information 142 Hamilton Syringes 143-146 700 Series MICROLITER Syringes

More information

More accurate results.

More accurate results. More choices. More productivity. More accurate results. Agilent's Complete Line of Autosampler and Manual Syringes Specifications and Selection Guide Table of Contents Introduction to Agilent Syringes...2

More information

Needle Gauge. Needle OD (mm) Needle ID (mm)

Needle Gauge. Needle OD (mm) Needle ID (mm) s LC Manual s Beckman/Altex, Rheodyne, SSI Instruments and Valco Valves s and Borosilicate Glass Barrel Outer Diameter () Scale 5 µl and 10 µl = 6.5 mm, 25 µl to 500 µl = 8 mm, 1 ml = 8.8 mm, 2.5 ml =

More information

AUTOMATED LIQUID HANDLING

AUTOMATED LIQUID HANDLING AUTOMATED LIQUID HANDLING Instrument Syringes R THE MEASURE OF EXCELLENCE TM The Measure of Excellence Automated Instrument Syringes When it comes to precision fluid handling, rely on the leader. We ve

More information

injections. Needle Tip 1 µl Cone 1BR

injections. Needle Tip 1 µl Cone 1BR s General Purpose Manual s 0.5-5 µl Nano With the ability to inject down to 50 nl with high precision and accuracy, SGE Nano s are perfect for Nano capillary chromatography injection as well as making

More information

Syringe Guide. The Measure of Excellence for your application

Syringe Guide. The Measure of Excellence for your application Syringe Guide The Measure of Excellence for your application Unsurpassed Accuracy and Precision Hamilton syringes are the finest quality precision fluid measuring devices available. Top quality materials

More information

Syringes & Liquid Handling

Syringes & Liquid Handling Syringes & Liquid Handling Hamilton Manual Syringes Manual Syringe Guide Microliter Syringes Gastight Syringes Syringe Accessories Syringe Cleaning & Maintenance Hamilton LC Autosampler Syringes CTC LC

More information

Liquid Chromatography Syringes

Liquid Chromatography Syringes Liquid Chromatography Syringes Hamilton manufactures a complete range of high performance liquid chromatography (HPLC) syringes and thin layer chromatography (TLC) syringes. HPLC Syringes HPLC syringes

More information

Syringe Care and Use Guide. Complete Guide to Maintaining and Using Hamilton Microliter, Gastight and Specialty Syringes

Syringe Care and Use Guide. Complete Guide to Maintaining and Using Hamilton Microliter, Gastight and Specialty Syringes Syringe Care and Use Guide Complete Guide to Maintaining and Using Hamilton Microliter, Gastight and Specialty Syringes TABLE OF CONTENTS Table of Contents Introduction...4 Syringe Use...6 Daily Use Protocol...6

More information

AUTOMATED LIQUID HANDLING

AUTOMATED LIQUID HANDLING AUTOMATED LIQUID HANDLING Instrument Syringes R THE MEASURE OF EXCELLENCE TM The Measure of Excellence Automated Instrument Syringes When it comes to precision fluid handling, rely on the leader. We ve

More information

Choose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide

Choose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide Choose for Your Instrument GC Supplies - Shimadzu Instrument Quick Pick Guide Syringes Septa Inlet Liners O-rings and Sealing Rings SilTite FingerTite Ferrules Ferrules Replacement Parts Your chromatography

More information

Gas Chromatography Syringe Selection Guide

Gas Chromatography Syringe Selection Guide Gas Chromatography Syringe Selection Guide Peter Morgan, Fisher, Runcorn, Cheshire, UK Technical Note 20552 Key Words Syringe selection Abstract Choosing the correct syringe from the wide selection available

More information

SYRINGE CARE AND USE. Complete Guide to Maintaining and Using Hamilton GASTIGHT, MICROLITER TM, and Specialty Syringes

SYRINGE CARE AND USE. Complete Guide to Maintaining and Using Hamilton GASTIGHT, MICROLITER TM, and Specialty Syringes SYRINGE CARE AND USE Complete Guide to Maintaining and Using Hamilton GASTIGHT, MICROLITER TM, and Specialty Syringes Table of Contents Introduction 3 Syringe Schematics 4 Syringe Use 5 Daily Use Protocol

More information

The Measure of Excellence. GC Autosampler Syringes. CTC GC PAL Autosampler Syringes (PAL is a registed trademark of CTC Analytics AG, Switzerland)

The Measure of Excellence. GC Autosampler Syringes. CTC GC PAL Autosampler Syringes (PAL is a registed trademark of CTC Analytics AG, Switzerland) The Measure of Excellence GC Autosampler Syringes For manual injection and for automatic injectors (autosamplers) from leading manufacturers you can choose from a wide variety of HAMILTON syringes. CTC

More information

Measurement, Separations, and More. More than 2,000 Syringes and Accessories

Measurement, Separations, and More. More than 2,000 Syringes and Accessories Measurement, Separations, and More More than 2,000 and Accessories TABLE OF CONTENTS Table of Contents... 3 Manual Sample Transfer and Manual HPLC...3-4 Manual GC... 5 HPLC Autosampler... 6 Featured Product:

More information

PEEK SS Columns & Guard Columns

PEEK SS Columns & Guard Columns PEEK SS Columns & Guard Columns ~ Stainless Steel Analytical Columns ~ PEEK Columns ID 2.1, 4.0, 4.6 & 7.5 mm ~ Jour-Guard Cartridges Stainless Steel or PEEK ~ Stainless Steel End Fittings 1/4 OD Columns

More information

INTEGRAL-BONNET NEEDLE VALVES H-300 SERIES

INTEGRAL-BONNET NEEDLE VALVES H-300 SERIES INTEGRAL-BONNET NEEDLE VALVES SERIES INTEGRAL-BONNET NEEDLE VALVES SERIES FEATURES n Straight and angle pattern n Stainless Steel and Brass construction n MAWP 5000 psi (345 bar) n MAWT 446 F (230 C) n

More information

ICP-OES Organics Kit Installation Instructions

ICP-OES Organics Kit Installation Instructions The ICP Organics Kit is an accessory for use with the Agilent ICP-OES instruments. It is available in two versions one for axial ICP-OES and the other for radial ICP-OES. It is used to analyze directly

More information

#20 Separation of Alcohols Using Gas Chromatography

#20 Separation of Alcohols Using Gas Chromatography #20 Separation of Alcohols Using Gas Chromatography Purpose: The purpose of this experiment is to determine the composition of an unknown alcohol mixture by using gas chromatography. Introduction: A gas

More information

PEEK Columns & Guard Columns

PEEK Columns & Guard Columns INDEX PEEK Columns 103 Packing Devices 104 Column Coupler One-Piece Fingertight 105 In-Line Biocompatible Guard Column 106 Column End Plugs 107 Column End Plugs, Logotype 107 Disclaimer The maximum holding

More information

Parts and Consumables. Sciclone ALH 3000 and Zephyr Liquid Handlers

Parts and Consumables. Sciclone ALH 3000 and Zephyr Liquid Handlers Parts and Consumables Sciclone ALH 3000 and Zephyr Liquid Handlers 2006 DISPOSABLE TIPS 3 ARRAYS 7 CONSUMABLE POSITIONING 8 ON-DECK ACCESSORIES 10 TEMPERATURE CONTROLLED LOCATORS 12 WASHING STATIONS 13

More information

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer HI 903 Karl Fischer Volumetric Titrator Measures 100 ppm to 100% water content Precision titrant delivery system 40,000 step, piston dosing pump Accurate to 0.1% Delivers as little as 0.125 µl of titrant

More information

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis

Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis Product Guide for LudgerSep TM ur2 UHPLC Column for DMB Sialic Acid Analysis Product # LS-UR2-2.1x100 Ludger Document # LS-uR2-DMB-Guide-v2.1 Ludger Ltd Culham Science Centre Oxford OX14 3EB United Kingdom

More information

Helping to protect you from exposure to hazardous drugs

Helping to protect you from exposure to hazardous drugs Helping to protect you from exposure to hazardous drugs Closed system solution: Texium closed male luer and SmartSite needle-free valve products What you can t see can hurt you The risks are well documented

More information

max airless Operating Manual for Dispenser Read this manual thoroughly before operating the Labmax airless!

max airless Operating Manual for Dispenser Read this manual thoroughly before operating the Labmax airless! Operating Manual for max airless Dispenser Read this manual thoroughly before operating the Labmax airless! witeg Labortechnik GmbH Am Bildacker 16 D-97866 Wertheim/Main Phone: +49 (0)9342 / 9301-0 Fax:

More information

Sterile hypodermic needles for single use Requirements and test methods

Sterile hypodermic needles for single use Requirements and test methods Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 7864 Fourth edition 2016-08-01 Sterile hypodermic needles for single use Requirements and test methods Aiguilles hypodermiques stériles, non réutilisables

More information

EASIMIP TM PATULIN Product Code: P250 / P250B

EASIMIP TM PATULIN Product Code: P250 / P250B EASIMIP TM PATULIN Product Code: P250 / P250B Molecularly imprinted polymer columns for use in conjunction with HPLC. For in vitro use only. P250B/V5/03.09.18 www.r-biopharm.com Contents Page Test Principle...

More information

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis

Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis Product # LS-R1-4.6x150 Ludger Document # LS-R1-DMB-Guide-v5.1 Ludger Ltd Culham Science Centre Oxford OX14 3EB United

More information

Double Block and Bleed ball valve have evolved to replace the process of bolting together individual valves to provide dual isolation.

Double Block and Bleed ball valve have evolved to replace the process of bolting together individual valves to provide dual isolation. Bleed valve Double Block and Bleed ball valve have evolved to replace the process of bolting together individual valves to provide dual isolation. This new assembly provides great savings in weight, space

More information

Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2

Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2 Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2 Ordering Information You may contact us via phone, fax, e-mail, or through our website. EPOND S.A. CP 389 CH-1800 Vevey Switzerland Phone:

More information

CORESTA RECOMMENDED METHOD N 8

CORESTA RECOMMENDED METHOD N 8 CORESTA RECOMMENDED METHOD N 8 DETERMINATION OF WATER IN THE MAINSTREAM SMOKE OF CIGARETTES BY GAS CHROMATOGRAPHIC ANALYSIS (August 1991) 1. FIELD OF APPLICATION The method is applicable to the particulate

More information

Safe Use of Needles. Year Group: All. Document number: CSL_U02

Safe Use of Needles. Year Group: All. Document number: CSL_U02 Year Group: All Document number: CSL_U02 Equipment for this station: Needles Syringes Sharps bin Equipment list: In most situations, you will not need to recap needles but will dispose directly into a

More information

Sensitive, Accurate and Precise. MS Solutions Through SGE Products. Diamond MS Syringes evol XR MEPS SilTite FingerTite GC Capillary Columns

Sensitive, Accurate and Precise. MS Solutions Through SGE Products. Diamond MS Syringes evol XR MEPS SilTite FingerTite GC Capillary Columns Sensitive, Accurate and Precise MS Solutions Through SGE Products Diamond MS Syringes evol XR MEPS SilTite FingerTite GC Capillary Columns AUSTRALIA & PACIFIC REGION EUROPE JAPAN USA Introduction Bringing

More information

DISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management

DISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management DISCOVER NEW HORIZONS IN FLUID DRAINAGE Bringing Safety and Convenience to Fluid Drainage Management DRAIN ASEPT Pleural and Peritoneal Drainage Catheter System 600mL or 1,000mL Evacuated Drainage Bottle

More information

THE CASE OF THE DRUNK DRIVER; GC APPROACH From Science in Motion, Juniata College

THE CASE OF THE DRUNK DRIVER; GC APPROACH From Science in Motion, Juniata College THE CASE OF THE DRUNK DRIVER; GC APPROACH From Science in Motion, Juniata College STANDARDS ADDRESSED 1.2.11.A, 2.4.11.E 3.4.10.A, 3.7.10.A 3.7.12.A INTRODUCTION ON GAS CHROMATOGRAPH Chromatography is

More information

autosamplers ASI-100 and ASI-100T Autosamplers

autosamplers ASI-100 and ASI-100T Autosamplers autosamplers ASI-100 and ASI-100T Autosamplers The ASI-100 and ASI-100T Automated Sample Injectors are highly flexible autosamplers for automating high performance liquid chromatography (HPLC) methods.

More information

This document is a preview generated by EVS

This document is a preview generated by EVS INTERNATIONAL STANDARD ISO 8537 Third edition 2016-03-15 Sterile single-use syringes, with or without needle, for insulin Seringues à insuline, stériles, non réutilisables, avec ou sans aiguille Reference

More information

Thermo Scientific Finntip Pipette Tips. HANDHELD PIPETTING Finntip Pipette Tips. Details

Thermo Scientific Finntip Pipette Tips. HANDHELD PIPETTING Finntip Pipette Tips. Details Thermo Scientific Finntip Pipette Tips Finntip* pipette tips are manufactured using high quality materials and the latest molding techniques for proven reliability. Thermo Scientific Finntip pipette tips

More information

QuickSplitTM Flow Splitters

QuickSplitTM Flow Splitters QuickTM Flow ters between 2 or more detectors such as Mass Spectroscopy and evaporative light scattering, UV, or IR. This is especially important when one of the detectors is destructive, such as Mass

More information

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual Page 1 / 14 Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual ZV-3051-0200-15 200 Page 2 / 14 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. TEST

More information

INSTRUCTIONS FOR USE

INSTRUCTIONS FOR USE Comfort Injects 50 Comfort-in INSTRUCTIONS FOR USE English user manual 1 Introduction Thank you for choosing the Comfort in Needle free Injection system, developed with your comfort and convenience in

More information

Super Clean TM. Gas Filters BIG TRAP INLINE FILTERS. Ideal for Central Purifying Solutions Largest Big Trap Available High Pressure Stainless Steel

Super Clean TM. Gas Filters BIG TRAP INLINE FILTERS. Ideal for Central Purifying Solutions Largest Big Trap Available High Pressure Stainless Steel Super Cln TM Gas Filters BIG TRAP INLINE FILTERS EP-B 04774871.0 U.S. Patent Pending 10/567,949 2015 WWW.SGT-NL.COM Idl for Central Purifying Solutions Largest Big Trap Available High Pressure Stainless

More information

InfinityLab Purification Capillary Kits

InfinityLab Purification Capillary Kits InfinityLab Purification Capillary Kits Technical Note This note describes the capillary connections for Agilent preparative systems. Agilent Technologies Contents Abbreviations 3 List of Modules 4 Overview

More information

Thermo Scientific Finnpipette Manual Pipetting Systems. you can handle. anything

Thermo Scientific Finnpipette Manual Pipetting Systems. you can handle. anything Thermo Scientific Manual Pipetting Systems you can handle anything Leader in Pipetting Technology Since the introduction of the first variable volume micropipette in 1971, more than four million Thermo

More information

MEDIUM-FLOW PNEUMOTACH TRANSDUCER

MEDIUM-FLOW PNEUMOTACH TRANSDUCER MEDIUM-FLOW PNEUMOTACH TRANSDUCER SS11LA for MP3x and MP45 System TSD117 & TSD117-MRI for MP150/MP100 System RX117 Replacement Airflow Head See also: AFT series of accessories for airflow and gas analysis

More information

Forensic Analysis of Blood Alcohol Concentration

Forensic Analysis of Blood Alcohol Concentration Application Note Forensics Forensic Analysis of Blood Alcohol Concentration Using the Agilent 886 GC with Agilent J&W DB BAC1 UI and Agilent J&W DB-BAC2 UI columns and the Agilent 7697A headspace sampler

More information

Lipidomic Analysis by UPLC-QTOF MS

Lipidomic Analysis by UPLC-QTOF MS Lipidomic Analysis by UPLC-QTOF MS Version: 1 Edited by: Oliver Fiehn Summary Reagents and Materials Protocol Summary:Lipidomic analysis by UPLC-QTOF mass spectrometry Reagents and Materials: Reagent/Material

More information

EASI-EXTRACT FOLIC ACID Product Code: P81 / P81B

EASI-EXTRACT FOLIC ACID Product Code: P81 / P81B EASI-EXTRACT FOLIC ACID Product Code: P81 / P81B Immunoaffinity columns for use in conjunction with HPLC or LC-MS/MS. For in vitro use only. P81/V16/13.04.15 www.r-biopharm.com Contents Page Test Principle...3

More information

Exactly what you re looking for. High Quality Instruments for Vitreoretinal Surgery

Exactly what you re looking for. High Quality Instruments for Vitreoretinal Surgery Exactly what you re looking for High Quality Instruments for Vitreoretinal Surgery Exactly what you re For over a decade, MedOne has been helping retina surgeons around the world conquer complex surgical

More information

YY Translated English of Chinese Standard: YY

YY Translated English of Chinese Standard: YY Translated English of Chinese Standard: YY0497-2005 www.chinesestandard.net Sales@ChineseStandard.net YY ICS 11.040.20 C 31 Pharmaceutical National Standard of the People s Republic of China YY 0497-2005

More information

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates

Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates Application Note Clinical Research Protein Precipitation for Biological Fluid Samples Using Agilent Captiva EMR Lipid 96-Well Plates Authors Limian Zhao and Megan Juck Agilent Technologies, Inc. Abstract

More information

Savillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES

Savillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES Savillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES Summary The Savillex C-Flow 700d (C700d) is a concentric PFA nebulizer designed specifically for ICP-OES, combining extreme matrix

More information

Calibration Standards

Calibration Standards Calibration Standards/ Calibration Standards TSKgel standards polystyrene TSKgel standards poly(ethylene oxide) PStQuick polystyrene calibration standards TSKgel guard column products Fittings Pre-injector

More information

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS

Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS Automated Sample Preparation for Profiling Fatty Acids in Blood and Plasma using the Agilent 7693 ALS Application Note Clinical Research Authors Frank David and Bart Tienpont, Research Institute for Chromatography,

More information

BROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / VACUUM

BROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / VACUUM BROEN UNIFLEX FITTINGS FOR NON-BURNING 2.0 GASES / ACUUM LAB TABLE OF CONTENTS Content Page Table of Content 2 Product Overview 3 BROEN UniFlex TM BASIC 4-5 Fittings for Non-burnig 2.0 Gases/acuum Turret

More information

Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL

Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL Bryan-Dumon Series II Rigid Bronchoscope and Stent Placement Kit USER MANUAL Table of Contents Bryan-DUmon Series II rigid bronchoscope 1. 2. 3. 4. 5. Diagram and Overview Universal Barrel Bronchial and

More information

micropipettes clinical laboratory single channel fully autoclavable

micropipettes clinical laboratory single channel fully autoclavable 46 clinical laboratory single channel micropipettes fully autoclavable High precision micro pipettes combine the highest levels of accuracy and precision with design innovations intended to make the pipetting

More information

Product Catalog 2016 EMEA

Product Catalog 2016 EMEA Product Catalog EMEA 2016 PORTFOLIO SOL-M Standard medical devices SOL-GUARD Basic safety medical devices SOL-CARE Innovative and advanced safety-engineered medical devices Sol-Millennium Europe Sp. z

More information

Shimadzu s Guide to Vial Selection. Not all vials are the same

Shimadzu s Guide to Vial Selection. Not all vials are the same Shimadzu s Guide to Vial Selection Not all vials are the same The perfect vial? Struggling to find the right vial or microtiter plate? You are not alone! What material? Are all vials the same? The Perfect

More information

Savillex Technical Note

Savillex Technical Note Savillex Technical Note C700d PFA Concentric Nebulizer for ICP-OES Summary The Savillex C-Flow 700d (C700d) is a concentric PFA nebulizer designed specifically for ICP-OES, combining extreme matrix tolerance

More information

Inline Filters (F Series) Catalog 4130-F July 2005

Inline Filters (F Series) Catalog 4130-F July 2005 Inline Filters (F Series) Catalog 4130-F July 2005 Catalog 4130-F Introduction Parker are designed for protection of instrumentation systems from undesirable materials. Component changes or repair and

More information

BIOPSY GUN. Delivered in sterile peel-open package. Device is made of Stainless Steel and PP material.

BIOPSY GUN. Delivered in sterile peel-open package. Device is made of Stainless Steel and PP material. BIOPSY GUN Biopsy Gun is a reusable system for histological core biopsies. It has a throw (advancement) of 25mm and is used in conjunction with a single use needle. This device is used to obtain tissue

More information

Purification - Flash Chromatography

Purification - Flash Chromatography SuperFlash Compound Purification Columns Optimal Design Cost effective, high performance disposable flash column specifically designed for flash chromatography. Excellent Separations Designed to deliver

More information

STANDARD SAMPLE INTRODUCTION

STANDARD SAMPLE INTRODUCTION STANDARD SAMPLE INTRODUCTION PFA and Polypropylene High-Efficiency MicroFlow Nebulizers MicroFlow nebulizers are resistant to clogging, are reliably self-aspirated or pumped and produce a fi ne aerosol

More information

BGS MODEL HP-165M FLUID END PARTS LIST

BGS MODEL HP-165M FLUID END PARTS LIST BGS MODEL HP-165M FLUID END PARTS LIST ITEM PART NUMBER REQ'D PART DESCRIPTION NO. QTY 001 BGS 008-024179-350 1 POWER FRAME 007 BGS 170-012005-353 1 PIPE PLUG, MAGNETIC 014 BGS 001-013059-999 1 FILTER/BREATHER

More information

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide

LeadCare BLOOD LEAD ANALYZER. Quick Reference Guide LeadCare II BLOOD LEAD ANALYZER Quick Reference Guide Precautions Precautions Caution The LeadCare II Blood Lead Analyzer is a CLIA-waived device. Facilities that perform tests with the LeadCare II System

More information

Savillex Technical Note

Savillex Technical Note Savillex Technical Note C400d PFA Concentric Nebulizer for ICP-MS Summary The Savillex C-Flow 400d (C400d) PFA concentric nebulizer combines the reliability of a low flow glass concentric nebulizer with

More information

Agilent 1220 Infinity LC System Performance Specifications

Agilent 1220 Infinity LC System Performance Specifications IET International Equipment Trading, Ltd. www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL +847.913.0777 for Refurbished & Certified Lab Equipment Agilent 1220 Infinity LC System Performance

More information

CORESTA Recommended Method No. 84

CORESTA Recommended Method No. 84 Cooperation Centre for Scientific Research Relative to Tobacco E-Vapour Sub-Group CORESTA Recommended Method No. 84 DETERMINATION OF GLYCERIN, PROPYLENE GLYCOL, WATER, AND NICOTINE IN THE AEROSOL OF E-CIGARETTES

More information

15 cm Reservoir Tubing. 210 cm Tubing

15 cm Reservoir Tubing. 210 cm Tubing 12 Aerosol Therapy nebulisers AEROSOL THERAPY MICRO MIST SMALL VOLUME NEBULISER The MICRO MIST small volume nebuliser is designed for performance and economy and can be used for hand-held or in-line treatments.

More information

THOMAFLUID - Handbook III

THOMAFLUID - Handbook III Reichelt Chemietechnik GmbH + Co. THOMAFLUID - Handbook III Capillary Connectors Micro Connectors Macro Connectors Pipe Connectors Welding Sleeves Bonded Socket Joints Plug-in Connectors HPLC Connectors

More information

FLUID MANAGEMENT FLUID MANAGEMENT

FLUID MANAGEMENT FLUID MANAGEMENT FLUID MANAGEMENT FLUID MANAGEMENT DualWave Arthroscopy Pump The DualWave is an integrated inflow and outflow fluid management system that may also be used as a simple inflow-only arthroscopy pump. The

More information

Restek PAL SPME Fibers cat.#

Restek PAL SPME Fibers cat.# 1 Restek PAL SPME Fibers cat.# 27478 27483 Solid phase microextraction (SPME) fibers are used to extract organic compounds from solid, liquid, and vapor matrices onto a stationary phase that is bonded

More information

ISO INTERNATIONAL STANDARD. Sterile single-use intravascular catheter introducers

ISO INTERNATIONAL STANDARD. Sterile single-use intravascular catheter introducers INTERNATIONAL STANDARD ISO 11070 First edition 1998-05-01 Sterile single-use intravascular catheter introducers Introducteurs de cathéters intravasculaires stériles, non réutilisables A Reference number

More information

Sterile hypodermic syringes for single use. Part 1: Syringes for manual use

Sterile hypodermic syringes for single use. Part 1: Syringes for manual use Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 7886-1 Second edition 2017-05 Sterile hypodermic syringes for single use Part 1: Syringes for manual use Seringues hypodermiques stériles, non

More information

CORESTA Guide N o 18

CORESTA Guide N o 18 CORESTA Guide N o 18 November 2016 Technical Guide for Sample Handling and Sample Collection of E-Cigarettes and E-Vapour Generating Products E-Vapour Sub-Group 1. REVIEW AND HISTORY Issue Date Reason

More information

WHAT WORKS? A comprehensive guide to safer needle and syringe selection for injecting drug users. Second edition. Fully revised and updated

WHAT WORKS? A comprehensive guide to safer needle and syringe selection for injecting drug users. Second edition. Fully revised and updated WHAT WORKS? A comprehensive guide to safer needle and syringe selection for injecting drug users Second edition Fully revised and updated What works? 2011 Exchange Supplies Second edition, 2016 What works?

More information

Innovations in Administration and Injection Systems EXPERIENCED CREATIVE FOCUSED

Innovations in Administration and Injection Systems EXPERIENCED CREATIVE FOCUSED Innovations in Administration and Injection Systems EXPERIENCED CREATIVE FOCUSED Meeting Your Drug Administration Challenges Your injectable drug product will be perfectly pure when you ship it, but will

More information

EASI-EXTRACT BIOTIN Product Code: P82 / P82B

EASI-EXTRACT BIOTIN Product Code: P82 / P82B EASI-EXTRACT BIOTIN Product Code: P82 / P82B Immunoaffinity columns for use in conjunction with HPLC or LC-MS/MS. For in vitro use only. AOAC Official First Action Method 2016.02 P82/V8/23.03.17 www.r-biopharm.com

More information

The Do s and Don ts of Pressure Transducers

The Do s and Don ts of Pressure Transducers The Do s and Don ts of Pressure Transducers ABSTRACT When specifying a pressure transducer for a process measurement, a number of items have to be considered. Some of the more important ones are discussed

More information

HI Total Acidity Mini Titrator for Water Analysis

HI Total Acidity Mini Titrator for Water Analysis HI 84530 Total Acidity Mini Titrator for Water Analysis Piston Driven Pump with Dynamic Dosing The HI 84530 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts the

More information

Needle Valves. We deliver confidence through quality products

Needle Valves. We deliver confidence through quality products We deliver confidence through quality products INTRODUCTION NEEDLE VALVES SD range of Needle valves come in various sizes, sealing styles, end connections and stem types. They are available in bar stock

More information

Wolf Laboratories Limited

Wolf Laboratories Limited Wolf Laboratories Limited www.wolflabs.co.uk Tel: 01759 301142 Fax:01759 301143 sales@wolflabs.co.uk Use the above details to contact us if this literature doesn't answer all your questions. Pricing on

More information

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family

Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family Galt Medical Corp. A leader in vascular and interventional medical devices. part of the GaltNeedleTech TM Family MICRO-INTRODUCERS Micro-Introducer Kits Galt s Micro-Introducer Kits with smooth transition,

More information

Ross Brown Sales Pty. Ltd. Portable Pressure/Vacuum Comparator

Ross Brown Sales Pty. Ltd. Portable Pressure/Vacuum Comparator Ross Brown Sales Pty. Ltd. Portable Pressure/Vacuum Comparator The data provided above is for information purposes only and no warranty of accuracy or reliability is given. Page 17 of 30 Pressure Generating

More information

HTEC-500 and 700 Series Related

HTEC-500 and 700 Series Related HTEC-500 and 700 Series Related Columns and Reagents 681.407.00 P3-AC -PC Prepacked AC Precolumn (3pcs/pkg) 450.00 3mm 681.406.00 P3-CH-PC Prepacked CH Precolumn (3 pcs/pkg) 450.00 3mm 681.405.00 P3-CA-PC

More information

Because your patients trust you to be your best

Because your patients trust you to be your best Because your patients trust you to be your best BD Anesthesia Solutions About BD Anesthesia Solutions A tradition of excellence in regional anesthesia BD has produced regional anesthesia products for most

More information

A FEW WORDS ABOUT US

A FEW WORDS ABOUT US Veterinary Product Catalogue 2018 A FEW WORDS ABOUT US SOL-MILLENNIUM Medical Group is a relatively new enterprise at just 10 years old, but is quickly building a reputation as a trusted, reliable and

More information

Ordering Information You may contact us via phone, fax, , or through our website.

Ordering Information You may contact us via phone, fax,  , or through our website. Elemental Scientific (ESI) designs and produces a range of sample introduction systems for the determination of trace element concentrations and isotope ratios in liquid samples when using inductively

More information

Adjustable Dumbbells selection

Adjustable Dumbbells selection We take the hassle out of ordering online and importing into Bermuda... We will get it for you!!!!!! Adjustable Dumbbells selection Bowflex SelectTech 1090s DumbBells $1,110.00 delivered Each dumbbell

More information

LINEAR. 7.5Fr. IAB Catheter. This document is intended to provide information to an international audience outside of the US.

LINEAR. 7.5Fr. IAB Catheter. This document is intended to provide information to an international audience outside of the US. LINEAR 7.5Fr. IAB Catheter This document is intended to provide information to an international audience outside of the US. Maquet offers a range of convenient and innovative clinical solutions for counterpulsation

More information

Thermo Finnigan. 6-2 LCQ Advantage Getting Started-

Thermo Finnigan. 6-2 LCQ Advantage Getting Started- To set up the LCQ Advantage to acquire data in the APCI/MS mode, you do the following:.install the APCI probe assembly.set up to infuse your analyte into the MS detector using a syringe pump connected

More information

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION TABLE OF CONTENTS EDITION 5 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2 - INTRODUCTION 2.1. INTRODUCTION 3 Section 3 - GENERAL 3.1. UNPACKING AND INSTALLATION

More information

OTAGO LIPOSURG. Compact, powerful system for infiltration and liposuction

OTAGO LIPOSURG. Compact, powerful system for infiltration and liposuction OTAGO LIPOSURG Compact, powerful system for infiltration and liposuction The Otago LipoSurg is the first medical device which allows infiltration and Liposuction in a single compact device. FEATURES AND

More information

J350, J360 and J370 PLUMBING PARTS CATALOG

J350, J360 and J370 PLUMBING PARTS CATALOG PREMIUM J0, J0 and J0 PLUMBING PARTS CATALOG PUMP Pump/Motor # * 0 * 00- HOUSING: FRONT 00-0 O-RING: FRONT HOUSING 00- IMPELLER:. DIA 00-0 PUMP: SEAL ASSY / VITON 00- HOUSING: REAR BRACKET 00-0 MOTOR:.HP

More information

QuickSplit TM Flow Splitters

QuickSplit TM Flow Splitters Quick TM Flow ters between 2 or more detecrs such as Mass Spectroscopy and evaporative light scattering, UV, or IR. This is especially important when one of the detecrs is destructive, such as Mass Spec

More information

Parts identification:

Parts identification: TRANSPARENT CATHETERIZATION SIMULATOR Parts identification: Clamp Urethra channel Prostate velcro strap (male genitalia only) Transparent Simulator Bladder tubing and luer locks Female genitalia Male genitalia

More information

INSTRUCTIONS FOR PREPARING AND GIVING AN INJECTION OF ENBREL POWDER

INSTRUCTIONS FOR PREPARING AND GIVING AN INJECTION OF ENBREL POWDER INSTRUCTIONS FOR PREPARING AND GIVING AN INJECTION OF ENBREL POWDER Introduction The following instructions explain how to prepare and inject Enbrel powder for injection. Please read the instructions carefully

More information