injections. Needle Tip 1 µl Cone 1BR
|
|
- Suzan Weaver
- 6 years ago
- Views:
Transcription
1 s General Purpose Manual s µl Nano With the ability to inject down to 50 nl with high precision and accuracy, SGE Nano s are perfect for Nano capillary chromatography injection as well as making accurate standards that require small volumes. The sample is only drawn into the needle, not the syringe barrel. When the plunger is depressed, the sample is completely dispensed by the Nano plunger that extends to the tip of the needle. Displacing the full sample during injection results in virtually zero dead volume and carry over between Reduced Diameter injections. The plungers and needles are matched sets and must be replaced as a set. Refer to page 65 for a list of replacement plunger and needle kits. Sample NOZZLE TIP SHOWN IN DIAGRAM. s and ± 2 % (dispensed volume) Borosilicate Glass Barrel Outer Diameter () 6.5 mm and 8 mm Scale 0.5 µl (6.5 mm barrel) = mm, 0.5 µl (8 mm barrel) = 63.7 mm, 1 µl = 54.1 mm, 63.7 mm, 5 µl = 48.7 mm Code and 6.5 mm Outer Diameter () Barrel 0.5 µl Cone 0.5BNR µl Bevel 0.5BNR-5BV µl Cone 0.5BNR-5/ mm Outer Diameter () Barrel 0.5 µl Cone 0.5BR µl Bevel 0.5BR-7BV µl Cone 1BR µl Bevel 1BR-5BV µl Cone 1BR µl Bevel 1BR-7BV µl Cone 1BR µl Cone 1BR-7/ µl Cone 5BR µl Bevel 5BR-5BV µl Cone 5BR µl Bevel 5BR-7BV µl Cone 5BR µl Nozzle 5BR-7N When replacing the plunger and needle follow the instructions included in the kit the front cover nut must be loosened before removing the plunger. s Fitted with Repeating Adaptor See page 63 for more details about the RAX repeating adaptor. Code and 6.5 mm Outer Diameter () Barrel 0.5 µl Cone 0.5BNR-5-RAX µl Cone 0.5BNR-5/0.47-RAX mm Outer Diameter () Barrel 0.5 µl Cone 0.5BR-7-RAX µl Cone 1BR-5-RAX µl Cone 1BR-7-RAX s General Purpose Manual s 35
2 s General Purpose Manual s 5-10 µl Metal s and Borosilicate Glass Barrel Outer Diameter () Scale ± 1 % (dispensed volume) 6.5 mm (guided plunger syringes 8 mm) 54.1 mm Standard Protection s Fixed Code 10 Pack 25 Pack 5 µl Bevel 5F µl Bevel 5F µl Cone 5F /0.63C 10 µl Bevel 10F µl Bevel 10F µl cone 10F-5C µl Bevel 10F µl Cone 10F- 4.2/0.63C Removable µl Bevel 5R µl Bevel 10R µl Bevel 10R SuperFlex s protection helps prevent plunger bending during injection. Code No Fixed 5 µl Bevel 5FX µl Cone 5FX-5C µl Bevel 10FX µl Bevel 10FX µl Cone 10FX-5C µl Cone 10FX-5/0.63C Removable 5 µl Bevel 5RX µl Bevel 10RX The virtually indestructible Titanium Nickel alloy plunger of the SuperFlex s is ideal for student use. 36 This selection guide can be viewed as an electronic book at sge.com/selectionguide
3 s and Guided s Guided plunger syringes are the most rugged syringe available, making them perfect for industrial environments. Fixed Code No 5 µl Bevel 5F-GP µl Bevel 10F-GP Removable 5 µl Bevel 5R-GP µl Bevel 5R-GP µl Bevel 5R-GPS * 10 µl Bevel 10R-GP µl Bevel 10R-GP * Short half scale syringe (scale length 27 mm). s Fitted with Repeating Adaptor See page 63 for more details about the RAX repeating adaptor. Fixed Code No 10 µl Bevel 10F-RAX Removable 5 µl Bevel 5R-RAX µl Bevel 10R-RAX Removable - Guided 5 µl Bevel 5R-GP-RAX µl Bevel 10R-GP-RAX µl Bevel 10R-GP-7-RAX The RAX repeating adaptor improves precision and reproducibility when repeatedly injecting the same volume manually. s General Purpose Manual s 37
4 s General Purpose Manual s µl Metal s and Borosilicate Glass Barrel Outer Diameter () Scale ± 1 % (dispensed volume) 8 mm 60 mm Code Fixed 25 µl Bevel 25F µl Bevel 50F µl Bevel 100F µl Bevel 250F µl Bevel 500F Removable 25 µl Bevel 25R µl Bevel 50R µl Bevel 100R µl Bevel 100R µl Bevel 250R µl Bevel 500R s Fitted with Repeating Adaptor See page 63 for more details about the RAX repeating adaptor. Code Removable 25 µl Bevel 25R-RAX µl Bevel 50R-RAX µl Bevel 100R-RAX µl Bevel 250R-RAX µl Bevel 500R-RAX To eliminate carryover between samples, flush the syringe with solvent 5-20 times, remembering to discard the first 2-3 washes. 38 For more syringe tips view our video at sge.com/support/videos
5 µl PTFE ped Borosilicate Glass Barrel Outer Diameter () Scale ± 1 % (dispensed volume) 10 µl = 6.5 mm, µl = 8 mm 10 µl = 54.1 mm, µl = 60 mm s and Fixed PTFE ped Code 10 µl Bevel 10F-GT µl Bevel 10F-GT µl Bevel 25F-GT µl Bevel 50F-GT µl Bevel 100F-GT µl Bevel 250F-GT µl Bevel 500F-GT Removable 10 µl Bevel 10R-GT µl Bevel 25R-GT µl Bevel 50R-GT µl Bevel 100R-GT µl Bevel 250R-GT µl Bevel 500R-GT Guided 10 µl Bevel 10R-GP-GT On-Column 10 µl On- Column Fixed Luer 10R-GT-OC- CE µl F-LT-GT µl F-LT-GT µl F-LT-GT µl F-LT-GT Fixed Luer Lock 50 µl F-LL-GT µl F-LL-GT µl F-LL-GT µl F-LL-GT s General Purpose Manual s 39
6 s General Purpose Manual s ml PTFE ped Also Suitable for Pumps and Dispensers s and Borosilicate Glass Barrel Outer Diameter () Scale Thread in Button ± 1 % (dispensed volume) 1 ml = 9 mm, 2.5 ml = 11 mm, 5 ml = 14 mm, 10 ml = 18 mm, 25 ml = 27 mm, 50 ml = 32.8 mm, 100 ml = 40.8 mm 1 25 ml = 60 mm, 50 ml = 84.2 mm, 100 ml = 104 mm 6-32 UNC PTFE ped Code Fixed 1 ml Bevel 1MDF-GT ml Bevel 2.5MDF-GT Removable 1 ml Bevel 1MR-GT * 2.5 ml Bevel 2.5MDR-GT ml Bevel 5MDR-GT ml Bevel 10MDR-GT Fixed Luer 1.0 ml Luer 1MF-LT-GT * 2.5 ml Luer 2.5MDF-LT-GT Fixed Luer Lock 1.0 ml Luer Lock 1MDF-LL-GT ml Luer Lock 2.5MDF-LL-GT ml Luer Lock 5MDF-LL-GT ml Luer Lock 10MDF-LL-GT ml Luer Lock 25MDF-LL-GT Removable Luer Lock 5 ml Luer Lock 5MDR-LL-GT ml Luer Lock 10MDR-LL-GT ml Luer Lock 25MR-LL-GT ml Luer Lock 50MR-LL-GT * 100 ml Luer Lock 100MR-LL-GT * * No thread in plunger stem of syringe part numbers , , and s Valves valves are ideal for sample storage and transportation or to pressurize sample prior to injection. SGE offers three basic types of manually operated syringe valves; push-pull for smaller volumes (25 µl 2.5 ml), septum and pushbutton for larger volumes (5 ml 2 L). SGE Luer, Luer Lock and removable needle syringes can be fitted with valves. The valve allows fluid to be stored in the syringe without contamination. 40 For more syringe tips view our video at sge.com/support/videos
7 Push-pull Valves Septum Valve Push-button Valves CLOSE OPEN OPEN CLOSE (Turn to close) OPEN s and and Push-pull valves suit removable needle 25 µl ml syringes The septum cap (P/N ) allows sample access without loss or contamination. It can be removed and Luer Lock needles or devices fitted Suits 5 ml - 2 L syringes with removable Luer Lock or removable needle Suitable for any Luer Lock and Luer syringes or other Luer devices. With the valve in the closed position it is possible to move the plunger to pre-pressurize the sample. Description Valve Code Valve Push-pull Valve with Replaceable µl ml V25/2.5M-0.63C * Push-pull Valve with Replaceable µl ml V25/2.5M-0.47C ˆ Push-pull Valve with Luer Lock 25 µl ml VLL25/2.5M Push-button Valve with Luer Lock or Removable 5 ml - 2 L VLLMA Septum Valve 5 ml - 2 L VLLMA5/ Push-button Valve for Luer Lock Devices 50 µl - 2 L SLLV * 50 mm, 0.63 mm cone tip needle. ˆ 50 mm, 0.47 mm cone tip needle. s Pre-fitted with Valves PTFE ped Code Valve Pre-fitted with Removable Push-pull Valve 50 µl 50R-V-GT µl 100R-V-GT µl 250R-V-GT µl 500R-V-GT ml 1MR-V-GT ml 2.5MDR-V-GT Pre-fitted with Luer Lock Valve 1 ml 1MR-VLL-GT ml 2.5MDR-VLL-GT ml 5MDR-VLLMA-GT ml 10MDR-VLLMA-GT ml 25MDR-VLLMA-GT ml 50MR-VLLMA-GT ml 100MR-VLLMA-GT Valve s For use with P/N and Pack Size Valve Cone Side Hole/Dome Cone See page 67 for the complete range of Luer Lock needles suitable for use on Luer Lock valves. s Valves 41
8 s valves SealTight s and SealTight low pressure valves are designed for improved valve seal life. SGE valves have overcome the problem of leakage by reducing perpendicular rotor force, and optimizing the rotor face union, thereby improving PTFE plug integrity. The end result is a longer life seal. The SealTight Valves are completely inert and enable connection of a variety of fittings. Valves are available in standard (SV) or bulkhead panel mounting connection (SVP) which can be easily mounted to a dispenser. Other valves, including custom OEM configurations, are available. Flow Path 1.5 mm (0.059") Threaded Ports 1/4 28 UNF Pressure Rating 120 psi Temperature Rating C Standard Weight 58 g Bulkhead Weight 65 g Breakaway Torque 0.15 Nm Lifetime Testing 8,000 cycles ADVANTAGES Extended life resulting from face rotor seal technology, making valves cost effective and reliable. Inert PTFE and Kel-F flow path compatible with a variety of solvents and sample matrices. Easily reassembled by hand: no need to torque it up like other valves. Screw thread for connection onto 5 ml 2 L syringes using syringe-valve connector ( ). APPLICATIONS Description Mounting Code Distribution Valves 2-way L Bulkhead SVP-2L/D way T Standard SV-3T/D way T Bulkhead SVP-3T/D Port Valves I flow 2 port Standard SV-2I/I T flow 3 port Standard SV-3T/T T flow 3 port Bulkhead SVP-3T/T L flow 3 port Standard SV-3T/L L flow 3 port Bulkhead SVP-3T/L SealTight Valve Fittings and Connectors 2-way L 3-way T I flow 2 port T flow 3 port L flow 3 port SealTight valves offer the versatility to be utilized in a variety of industries and applications: Dispensers. Diluters. Flow path variation. Biocompatible, suitable for use in pathology equipment. Description Code Kel-F Female Luer KSV-FL Kel-F Male Luer KSV-LT Metal Thread Male Luer Lock - PTFE Flow Path MSV-LL Valve Connector (fits 5 ml 2 L syringes) PTFE Flow Path MSV-SYR Flangeless Tubing Connector for 1/16" Tubing (includes 2 ferrules) MSV-1/ Flangeless Tubing Connector for 1/8" Tubing (includes 2 ferrules) MSV-1/8FLT Ferrules for 1/16" Tubing PF Ferrules for 1/8" Tubing PF s Valves
Needle Gauge. Needle OD (mm) Needle ID (mm)
s LC Manual s Beckman/Altex, Rheodyne, SSI Instruments and Valco Valves s and Borosilicate Glass Barrel Outer Diameter () Scale 5 µl and 10 µl = 6.5 mm, 25 µl to 500 µl = 8 mm, 1 ml = 8.8 mm, 2.5 ml =
More informationHamilton Syringes. LT N LTN RN TLL TLL with slots. Hamilton Syringe Types Microliter. Hamilton Point Styles
Hamilton LT N LTN RN TLL TLL with slots Hamilton Point Styles Pt. 2 Pt. 3 Pt. 5 Pt. HP Hamilton syringes are designed as precision measuring instruments, and find wide use for sample introduction into
More informationAUTOMATED LIQUID HANDLING
AUTOMATED LIQUID HANDLING Instrument Syringes R THE MEASURE OF EXCELLENCE TM The Measure of Excellence Automated Instrument Syringes When it comes to precision fluid handling, rely on the leader. We ve
More informationMore accurate results.
More choices. More productivity. More accurate results. Agilent's Complete Line of Autosampler and Manual Syringes Specifications and Selection Guide Table of Contents Introduction to Agilent Syringes...2
More informationAUTOMATED LIQUID HANDLING
AUTOMATED LIQUID HANDLING Instrument Syringes R THE MEASURE OF EXCELLENCE TM The Measure of Excellence Automated Instrument Syringes When it comes to precision fluid handling, rely on the leader. We ve
More informationSelecting The Right Syringe
Selecting The Right Syringe Choosing the Right Hamilton Syringe for Your Application 1. Is your sample a gas or a liquid? For a gas sample, use a GASTIGHT syringe. GASTIGHT 1000, 1700 and 1800 Series 1000/1700
More informationcataleg-inl-2007-def6.indd /01/ :27:30
140 cataleg-inl-2007-def6.indd 140 30/01/2009 17:27:30 Index Syringes Hamilton Syringes Content Page Content Page Hamilton General Information 142 Hamilton Syringes 143-146 700 Series MICROLITER Syringes
More informationChoose for Your Instrument. GC Supplies - Shimadzu Instrument Quick Pick Guide
Choose for Your Instrument GC Supplies - Shimadzu Instrument Quick Pick Guide Syringes Septa Inlet Liners O-rings and Sealing Rings SilTite FingerTite Ferrules Ferrules Replacement Parts Your chromatography
More informationNeedle Valves. We deliver confidence through quality products
We deliver confidence through quality products INTRODUCTION NEEDLE VALVES SD range of Needle valves come in various sizes, sealing styles, end connections and stem types. They are available in bar stock
More informationSavillex Technical Note
Savillex Technical Note C400d PFA Concentric Nebulizer for ICP-MS Summary The Savillex C-Flow 400d (C400d) PFA concentric nebulizer combines the reliability of a low flow glass concentric nebulizer with
More informationmax airless Operating Manual for Dispenser Read this manual thoroughly before operating the Labmax airless!
Operating Manual for max airless Dispenser Read this manual thoroughly before operating the Labmax airless! witeg Labortechnik GmbH Am Bildacker 16 D-97866 Wertheim/Main Phone: +49 (0)9342 / 9301-0 Fax:
More informationSTANDARD SAMPLE INTRODUCTION
STANDARD SAMPLE INTRODUCTION PFA and Polypropylene High-Efficiency MicroFlow Nebulizers MicroFlow nebulizers are resistant to clogging, are reliably self-aspirated or pumped and produce a fi ne aerosol
More informationTHOMAFLUID - Handbook III
Reichelt Chemietechnik GmbH + Co. THOMAFLUID - Handbook III Capillary Connectors Micro Connectors Macro Connectors Pipe Connectors Welding Sleeves Bonded Socket Joints Plug-in Connectors HPLC Connectors
More informationPEEK SS Columns & Guard Columns
PEEK SS Columns & Guard Columns ~ Stainless Steel Analytical Columns ~ PEEK Columns ID 2.1, 4.0, 4.6 & 7.5 mm ~ Jour-Guard Cartridges Stainless Steel or PEEK ~ Stainless Steel End Fittings 1/4 OD Columns
More informationSyringe Guide. The Measure of Excellence for your application
Syringe Guide The Measure of Excellence for your application Unsurpassed Accuracy and Precision Hamilton syringes are the finest quality precision fluid measuring devices available. Top quality materials
More informationLiquid Chromatography Syringes
Liquid Chromatography Syringes Hamilton manufactures a complete range of high performance liquid chromatography (HPLC) syringes and thin layer chromatography (TLC) syringes. HPLC Syringes HPLC syringes
More informationINTEGRAL-BONNET NEEDLE VALVES H-300 SERIES
INTEGRAL-BONNET NEEDLE VALVES SERIES INTEGRAL-BONNET NEEDLE VALVES SERIES FEATURES n Straight and angle pattern n Stainless Steel and Brass construction n MAWP 5000 psi (345 bar) n MAWT 446 F (230 C) n
More informationMechanically actuated valves
Mechanically actuated valves /2-5/2 spool valves with /8 NPT threaded ports Installation in any position Comprehensive range of actuations, direct or servo-piloted Special versions on request Materials
More informationTJF-160F/VF Cleaning and Disinfection Checklist
TJF-160F/VF Cleaning and Disinfection Checklist TJF-160F/VF Cleaning and Disinfection Checklist This checklist is used to evaluate and confirm if cleaning and disinfection of the TJF-160F/VF has been performed
More informationGas Chromatography Syringe Selection Guide
Gas Chromatography Syringe Selection Guide Peter Morgan, Fisher, Runcorn, Cheshire, UK Technical Note 20552 Key Words Syringe selection Abstract Choosing the correct syringe from the wide selection available
More informationIn-Line Accessories. In-Line Pressure Gauges. Pressure Gauges. In-Line Accessories
Pressure Gauges Pressure gauges for monitoring system pressure Hoses and test points for sampling oil and determining ISO cleanliness levels Flanges to connect components Valves for system control In-Line
More informationautosamplers ASI-100 and ASI-100T Autosamplers
autosamplers ASI-100 and ASI-100T Autosamplers The ASI-100 and ASI-100T Automated Sample Injectors are highly flexible autosamplers for automating high performance liquid chromatography (HPLC) methods.
More informationSavillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES
Savillex Technical Note C-Flow 700d PFA Concentric Nebulizer for ICP-OES Summary The Savillex C-Flow 700d (C700d) is a concentric PFA nebulizer designed specifically for ICP-OES, combining extreme matrix
More informationPlant, components and devices for very high and high pressures (7000 bar and over)
Plant, components and devices for very high and high pressures (7000 bar and over) VALVES AND FITTINGS UP TO 1035 BAR MATERIALS All fittings are manufactured from EN 1.4404 / AISI 316L stainless steel
More informationPEEK Columns & Guard Columns
INDEX PEEK Columns 103 Packing Devices 104 Column Coupler One-Piece Fingertight 105 In-Line Biocompatible Guard Column 106 Column End Plugs 107 Column End Plugs, Logotype 107 Disclaimer The maximum holding
More informationMeasures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer
HI 903 Karl Fischer Volumetric Titrator Measures 100 ppm to 100% water content Precision titrant delivery system 40,000 step, piston dosing pump Accurate to 0.1% Delivers as little as 0.125 µl of titrant
More informationINSTRUCTIONS FOR USE
Comfort Injects 50 Comfort-in INSTRUCTIONS FOR USE English user manual 1 Introduction Thank you for choosing the Comfort in Needle free Injection system, developed with your comfort and convenience in
More informationA step-by-step preparation guide
A step-by-step preparation guide For needle and needle-free systems This guide provides detailed instructions on the reconstitution, dilution, and storage of VELETRI. It is intended to be used after your
More informationHelping to protect you from exposure to hazardous drugs
Helping to protect you from exposure to hazardous drugs Closed system solution: Texium closed male luer and SmartSite needle-free valve products What you can t see can hurt you The risks are well documented
More informationSkydrol Crystal Pressure Fittings CPF
Common Specifications (applies to all CPF fittings in this datasheet) DESCRIPTION CPF is an improved cone type fitting system that adds a unique o-ring sealing system which permits leak free connections
More informationSavillex Technical Note
Savillex Technical Note C700d PFA Concentric Nebulizer for ICP-OES Summary The Savillex C-Flow 700d (C700d) is a concentric PFA nebulizer designed specifically for ICP-OES, combining extreme matrix tolerance
More informationCrystal Pressure Fittings CPF
Common Specifications (applies to all CPF fittings in this datasheet) DESCRIPTION CPF is an improved cone type fitting system that adds a unique o-ring sealing system which permits leak free connections
More informationPurification - Flash Chromatography
SuperFlash Compound Purification Columns Optimal Design Cost effective, high performance disposable flash column specifically designed for flash chromatography. Excellent Separations Designed to deliver
More informationLION. Application Note PRECISION. Linear Position Measurement with Eddy-Current Sensors. LA March, Applicable Equipment: Applications:
LION PRECISION Application Note LA02-0061 March, 2013 Linear Position Measurement with Eddy-Current Sensors Position, Displacement Applicable Equipment: Eddy-Current position measurement systems. Applications:
More informationEducation for self administration of intravenous therapy HOME IV THERAPY. 30 minute - Baxter Pump Tobramycin
HOME IV THERAPY Tobramycin Tobramycin Check the order on the drug chart This can change when the results from your blood test come through. Your doctor will change the order, if required. A copy of the
More informationCATHETER ACCESS KIT. For use with Prometra Programmable Infusion Systems
CATHETER ACCESS KIT Caution: Federal (USA) Law restricts this device to sale by or on the order of a physician. Table of Contents Contents... 3 Description... 3 Indications... 3 Contraindications... 3
More informationSyringe Care and Use Guide. Complete Guide to Maintaining and Using Hamilton Microliter, Gastight and Specialty Syringes
Syringe Care and Use Guide Complete Guide to Maintaining and Using Hamilton Microliter, Gastight and Specialty Syringes TABLE OF CONTENTS Table of Contents Introduction...4 Syringe Use...6 Daily Use Protocol...6
More informationA FEW WORDS ABOUT US
Veterinary Product Catalogue 2018 A FEW WORDS ABOUT US SOL-MILLENNIUM Medical Group is a relatively new enterprise at just 10 years old, but is quickly building a reputation as a trusted, reliable and
More informationSensitive, Accurate and Precise. MS Solutions Through SGE Products. Diamond MS Syringes evol XR MEPS SilTite FingerTite GC Capillary Columns
Sensitive, Accurate and Precise MS Solutions Through SGE Products Diamond MS Syringes evol XR MEPS SilTite FingerTite GC Capillary Columns AUSTRALIA & PACIFIC REGION EUROPE JAPAN USA Introduction Bringing
More informationY s A P. n n. C o. e c. t o r s E R. e s. e l. e e d l I V. e d o s C l. vadsite The Transparent, Split Septum, Needleless Connector
I V T H N E R e e d l A P e l e s Y s C o n n e c t o r s e d o s C l vadsite The Transparent, Split Septum, Needleless Connector What is vadsite? vadsite is a Neutral Displacement Needleless Connector
More informationFITTINGS. Pneufit C composite and Pneufit M fittings Inch Ø 1/8" to 1/2" O/D tube
Pneufit C composite and Pneufit M fittings Ø 1/8" to 1/2" Ready to use. Over 1,000 composite push-in pneumatic fittings. Releasable stainless-steel grab-ring to grip nylon or polyurethane (8 or 9 durometer).
More informationQuickSplitTM Flow Splitters
QuickTM Flow ters between 2 or more detectors such as Mass Spectroscopy and evaporative light scattering, UV, or IR. This is especially important when one of the detectors is destructive, such as Mass
More informationNeedle Valves Catalog 4110-NV December 2010
Needle Valves Catalog 4110-NV December 2010 Series Needle Valves Catalog 4110-NV Introduction Parker Series nion onnet Valves have been engineered for use at pressures up to 6,000 (414 bar) and temperatures
More informationCONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED ARC 5 ELECTRONIC CIGARETTE KIT.
USER MANUAL YOUR ARC 5 BATTERY CS AIR SLIM TANK Tank connection Mouthpiece CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED ARC 5 ELECTRONIC CIGARETTE KIT. UP adjustment button DOWN adjustment button
More informationImpact resistant PBT body in black for Pneufit C and light gray for Pneufit M.
Pneufit C composite and Pneufit M fittings Ø Â" to Ë" Ready to use. Over 1,000 composite push-in pneumatic fittings. Releasable stainless-steel grab-ring to grip nylon or polyurethane (85 or 95 durometer).
More informationInfinityLab Purification Capillary Kits
InfinityLab Purification Capillary Kits Technical Note This note describes the capillary connections for Agilent preparative systems. Agilent Technologies Contents Abbreviations 3 List of Modules 4 Overview
More informationAutotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from
Technical Information and Specifications detailed specification sheets from www.malvern.co.uk/autotitrator MPT-2 Autotitrator Description The MPT-2 autotitrator is an optional accessory compatible with
More informationCrystal Pressure Fittings CPF
Common Specifications (applies to all CPF fittings in this datasheet) DESCRIPTION CPF is an improved cone type fitting system that adds a unique o-ring sealing system which permits leak free connections
More informationActivity # 4. Measurement of Enzyme Activity
Activity # 4. Measurement of Enzyme Activity Adapted from Experimental Molecular Biology Lab Manual, Stephen H. Munroe, Marquette University Week 1 Protein Extraction, Concentration Measurement & Instrument
More informationLateral Flow Reagent Dispenser Instruction Manual
Lateral Flow Reagent Dispenser Instruction Manual 1182 Monte Vista Ave. Suite #11 Claremont, CA 91786 0 Phone: 909-920-3887 Fax: 909-946-1132 Specifications Dimensions (L x W x H): 457 x 146 x 75 mm (excluding
More informationYY Translated English of Chinese Standard: YY
Translated English of Chinese Standard: YY0497-2005 www.chinesestandard.net Sales@ChineseStandard.net YY ICS 11.040.20 C 31 Pharmaceutical National Standard of the People s Republic of China YY 0497-2005
More informationEducation for Self Administration of Intravenous Therapy HOME IV THERAPY PICC. Portacath
HOME IV THERAPY PICC Portacath Who To contact Cardio-Respiratory Integrated Specialist Services (CRISS) Office hours 0800 1630 hours Ph: 364 0167 Weekends and after hours, phone Christchurch Hospital operator
More informationSterile hypodermic syringes for single use. Part 1: Syringes for manual use
Provläsningsexemplar / Preview INTERNATIONAL STANDARD ISO 7886-1 Second edition 2017-05 Sterile hypodermic syringes for single use Part 1: Syringes for manual use Seringues hypodermiques stériles, non
More informationSYRINGE CARE AND USE. Complete Guide to Maintaining and Using Hamilton GASTIGHT, MICROLITER TM, and Specialty Syringes
SYRINGE CARE AND USE Complete Guide to Maintaining and Using Hamilton GASTIGHT, MICROLITER TM, and Specialty Syringes Table of Contents Introduction 3 Syringe Schematics 4 Syringe Use 5 Daily Use Protocol
More informationElemental Scientific Semiconductor Catalog for Thermo ELEMENT2
Elemental Scientific Semiconductor Catalog for Thermo ELEMENT2 Ordering Information You may contact us via phone, fax, e-mail, or through our website. EPOND S.A. CP 389 CH-1800 Vevey Switzerland Phone:
More informationSAFEty. Medicina Intravenous safety systems
SAFEty Medicina Intravenous safety systems There is significant evidence that safer products should be more widely used, but until now these alternatives have been significantly more expensive. SAFEty
More informationDISCOVER NEW HORIZONS IN FLUID DRAINAGE. Bringing Safety and Convenience to Fluid Drainage Management
DISCOVER NEW HORIZONS IN FLUID DRAINAGE Bringing Safety and Convenience to Fluid Drainage Management DRAIN ASEPT Pleural and Peritoneal Drainage Catheter System 600mL or 1,000mL Evacuated Drainage Bottle
More informationThermo Finnigan. 6-2 LCQ Advantage Getting Started-
To set up the LCQ Advantage to acquire data in the APCI/MS mode, you do the following:.install the APCI probe assembly.set up to infuse your analyte into the MS detector using a syringe pump connected
More information#NPPG2016. ENFit syringes. Andrew Wignell, Paediatric Pharmacist, Nottingham University Hospitals
#NPPG2016 ENFit syringes Andrew Wignell, Paediatric Pharmacist, Nottingham University Hospitals ENFit Syringes Andrew Wignell andrew.wignell@nuh.nhs.uk Objectives Describe the background to the changes
More informationCATHETERIZATION TRAINER ON A STAND
CATHETERIZATION TRAINER ON A STAND Parts identification: Clamp Prostate velcro strap (male genitalia only) Genitalia stand male female Urethra channel Bladder tubing and luer locks Female genitalia Male
More informationTHE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT
USER MANUAL THE TOTALLY WICKED TORNADO NC CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED TORNADO NC ELECTRONIC CIGARETTE KIT 3 QUICK START GUIDE For those familiar with e-cigarettes, the steps below
More informationInstallation, operation and service manual BMA 04
BMA 04 Please read this manual carefully before installing and using the BMA 04 safe measuring coupling. Wigersma & Sikkema warranty obligations do not apply in case of non-observance of this manual. 1
More informationPatient Information Publications Warren Grant Magnuson Clinical Center National Institutes of Health
Warren Grant Magnuson Clinical Center National Institutes of Health What is a subcutaneous injection? A subcutaneous injection is given in the fatty layer of tissue just under the skin. A subcutaneous
More informationISO INTERNATIONAL STANDARD. Sterile single-use intravascular catheter introducers
INTERNATIONAL STANDARD ISO 11070 First edition 1998-05-01 Sterile single-use intravascular catheter introducers Introducteurs de cathéters intravasculaires stériles, non réutilisables A Reference number
More informationBAYER: KOGENATE FS WITH BIOSET (Recombinant FVIII)
BAYER: KOGENATE FS WITH BIOSET (Recombinant FVIII) KOGENATE FS, Recombinant Antihemophilic Factor, is indicated for the prevention and control of bleeding episodes in people with hemophilia A (classical
More informationPART III: CONSUMER INFORMATION
IMPORTANT: PLEASE READ PART III: CONSUMER INFORMATION NiaStase RT (eptacog alfa, activated) Activated Recombinant Human Blood Coagulation Factor VII Room Temperature Stable This leaflet is Part III of
More informationISO INTERNATIONAL STANDARD. Sterile hypodermic syringes for single use Part 4: Syringes with re-use prevention feature
INTERNATIONAL STANDARD ISO 7886-4 First edition 2006-10-01 Sterile hypodermic syringes for single use Part 4: Syringes with re-use prevention feature Seringues hypodermiques stériles, non réutilisables
More informationInstructions For Use. SOLUTION FOR INJECTION IN PRE-FILLED PEN 250 micrograms
Instructions For Use SOLUTION FOR INJECTION IN PRE-FILLED PEN 250 micrograms Contents 1. How to use your Ovitrelle pre-filled pen 2. Before you start using your Ovitrelle pre-filled pen 3. Getting your
More informationALPROLIX Coagulation Factor IX (Recombinant), Fc Fusion Protein INSTRUCTIONS FOR USE Do not Do not YOUR KIT CONTAINS:
ALPROLIX Coagulation Factor IX (Recombinant), Fc Fusion Protein INSTRUCTIONS FOR USE Read the Instructions for Use before you start using ALPROLIX and each time you get a refill. There may be new information.
More informationSyringes & Liquid Handling
Syringes & Liquid Handling Hamilton Manual Syringes Manual Syringe Guide Microliter Syringes Gastight Syringes Syringe Accessories Syringe Cleaning & Maintenance Hamilton LC Autosampler Syringes CTC LC
More informationACE CN-ES. Extra Stability. Extended Spacer. Enhanced Selectivity ACE. Combining CN polar selectivity with enhanced hydrophobicity
ACE CN-ES Combining CN polar selectivity with enhanced hydrophobicity Extended Spacer Extra Stability New stationary phase technology for UHPLC and HPLC separations Alternative polar selectivity for method
More informationParts identification:
TRANSPARENT CATHETERIZATION SIMULATOR Parts identification: Clamp Urethra channel Prostate velcro strap (male genitalia only) Transparent Simulator Bladder tubing and luer locks Female genitalia Male genitalia
More informationCONFIGURE YOUR OWN CUSTOM-MADE SUPERIOR FOLLICLE ASPIRATION SET IN 7 STEPS
CONFIGURE YOUR OWN CUSTOM-MADE SUPERIOR FOLLICLE ASPIRATION SET IN 7 STEPS COPY OR DOWNLOAD AT WWW.GYNETICS.BE, COMPLETE AND RETURN FOR INQUIRY STEP 1 CHOOSE YOUR FLUSH NEEDLE TICK BOX Needle Lumen Gauge
More informationProduct Catalog 2016 EMEA
Product Catalog EMEA 2016 PORTFOLIO SOL-M Standard medical devices SOL-GUARD Basic safety medical devices SOL-CARE Innovative and advanced safety-engineered medical devices Sol-Millennium Europe Sp. z
More informationPfizer, BeneFIX R2 Recombinant Factor IX
Pfizer, BeneFIX R2 Recombinant Factor IX BeneFIX, Recombinant Factor IX, is indicated for the prevention and control of bleeding episodes in people with hemophilia B (Christmas Disease). BeneFIX is also
More informationa state of the art 04-23 24-29 29 30-34 36 37-45 REVERSE OSMOSIS SYSTEMS Traditional Systems / Economic Series 1520059001 EC-105 :: STANDARD 5 FILTER RO SYSTEM 1520059002 EC-106 :: STANDARD 6 FILTER RO
More informationWHAT WORKS? A comprehensive guide to safer needle and syringe selection for injecting drug users. Second edition. Fully revised and updated
WHAT WORKS? A comprehensive guide to safer needle and syringe selection for injecting drug users Second edition Fully revised and updated What works? 2011 Exchange Supplies Second edition, 2016 What works?
More informationThermo Scientific Finntip Pipette Tips. HANDHELD PIPETTING Finntip Pipette Tips. Details
Thermo Scientific Finntip Pipette Tips Finntip* pipette tips are manufactured using high quality materials and the latest molding techniques for proven reliability. Thermo Scientific Finntip pipette tips
More informationSavillex Technical Note
Savillex Technical Note C-Flow PFA Microconcentric Nebulizer Range Summary The Savillex C-Flow PFA concentric nebulizer range comprises of the general purpose C700d (nominal uptake 700 ul/min), suitable
More informationAdministering Intravenous Medication By Syringe Pump
Administering Intravenous Medication By Syringe Pump CEAC 0820 February 2015 Administering Intravenous Medication By Syringe Pump You must change the tubing every day around the same time each day. Always
More informationStandard Operating Procedure for cannulation
Standard Operating Procedure for cannulation Effective date: 26.07.2017 Review due date: 31.03.2019 Original Author Name: Richard Metcalfe Position: PhD Student Date: 05.12.2012 Reviewer Name: Pippa Heath
More informationProduct Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis
Product Guide for LudgerSep TM R1 HPLC Column for DMB labelled Sialic Acid Analysis Product # LS-R1-4.6x150 Ludger Document # LS-R1-DMB-Guide-v5.1 Ludger Ltd Culham Science Centre Oxford OX14 3EB United
More informationHumaPen LUXURA HD INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE
1 HumaPen LUXURA HD INSULIN DELIVERY DEVICE INSTRUCTIONS FOR USE For use only with Lilly 3 ml insulin cartridges (100 units/ml). Do not use other brands of insulin cartridges. The color of your HumaPen
More informationINSTRUCTIONS FOR PREPARING AND GIVING AN INJECTION OF ENBREL POWDER
INSTRUCTIONS FOR PREPARING AND GIVING AN INJECTION OF ENBREL POWDER Introduction The following instructions explain how to prepare and inject Enbrel powder for injection. Please read the instructions carefully
More informationAward Matrix HPVC Intravenous Access Devices and Administration Consumables (Effective 1st March 2017)
Award Matri HPVC2013-079 Intravenous Access Devices and Administration Consumables (Effective 1st March 2017) Product Category Bater Healthcare Telefle Medical Australia Medifle Industries 01- PERIPHERAL
More informationEQUASHIELD II Closed System. Technical Spe. FDA cleared under ONB product code and substantiated to prevent microbial ingress up to 7 days
EQUASHIELD II Closed System Technical Spe FDA cleared under ONB product code and substantiated to prevent microbial ingress up to 7 days The System F E A T U R E S The clinically proven EQUASHIELD Closed
More informationMisc: Interchange Coupling
Wing Style Interchange Coupling Misc: Interchange Coupling Series: W Interchange: Parker 6100 - Seals: Nitrile - Threaded sleeve allows connection/disconnection under pressure - Coupler: brass material
More informationNEW! Thermo Scientific ClipTip Pipetting Systems. sealed in security. feel the difference
NEW! Thermo Scientific ClipTip Pipetting Systems sealed in security feel the difference Breakthrough ClipTip technology See it in action at: www.fishersci.com/handleanything Achieve newfound confidence
More informationParts and Consumables. Sciclone ALH 3000 and Zephyr Liquid Handlers
Parts and Consumables Sciclone ALH 3000 and Zephyr Liquid Handlers 2006 DISPOSABLE TIPS 3 ARRAYS 7 CONSUMABLE POSITIONING 8 ON-DECK ACCESSORIES 10 TEMPERATURE CONTROLLED LOCATORS 12 WASHING STATIONS 13
More information12 series (Pneufit) Push-in fittings
> > Port size: Ø /8... /2, Ø 4... 2 mm tube size, SP and NPT threads > > Very compact units > > asy tube insertion for rapid assembly of pneumatic circuits > > Positive tube anchorage > > ll taper threads
More informationDePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0)
Reference: 1. Data on file at DePuy Spine TM 2008 DePuy Spine International is a joint venture with Biedermann Motech, GmbH. This publication is not intended for distribution in the USA. X-ray on front
More informationInstallation, operation and service manual BMA 05
BMA 05 Please read this manual carefully before installing and using the BMA 05 safe measuring coupling. Wigersma & Sikkema warranty obligations do not apply in case of non-observance of this manual. 1
More informationTop Performance. Uncompromising from the bottom to the top Eppendorf Varispenser 2 and Varispenser 2x
Top Performance Uncompromising from the bottom to the top Eppendorf Varispenser 2 and Varispenser 2x 2 Varispenser 2/2x Eppendorf Varispenser 2 / 2x For laboratory tasks with aliquots of aggressive solutions
More informationNONGYNECOLOGICAL CYTOLOGY FINE NEEDLE ASPIRATION SPECIMENS
NONGYNECOLOGICAL CYTOLOGY FINE NEEDLE ASPIRATION SPECIMENS I. Purpose Fine needle aspiration of mass lesions is commonly utilized in the detection and characterization of a variety of malignant diseases.
More informationAutopen 24 is an easy to use insulin injection pen, designed for use with 3.0ml sanofi aventis insulin cartridges. Compatible with all pen needles*.
Instructions for use English Autopen 24 is an easy to use insulin injection pen, designed for use with 3.0ml sanofi aventis insulin cartridges. Compatible with all pen needles*. PLEASE FOLLOW THESE STEP-BY-STEP
More informationELECTRONIC CIGARETTE KIT USER MANUAL
ELECTRONIC CIGARETTE KIT USER MANUAL Mouthpiece Sliding Top Cap CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED OPTIMUS ELECTRONIC CIGARETTE KIT. Airflow Control Ring LED Indicator Light OLED Screen
More informationThis document is a preview generated by EVS
INTERNATIONAL STANDARD ISO 8537 Third edition 2016-03-15 Sterile single-use syringes, with or without needle, for insulin Seringues à insuline, stériles, non réutilisables, avec ou sans aiguille Reference
More informationCigarette Smoking Machine CSM-SCSM. User s Manual
Cigarette Smoking Machine CSM-SCSM User s Manual CH TECHNOLOGIES (USA), Inc. Copyright 2011 CONTENTS 1. Introduction... 3 2. CSM-SCSM Description... 3 3. CSM-SCSM Specifications...6 4. Preparation of CSM-SCSM
More information