Reliability of Nested PCR for Detection of Chlamydia pneumoniae DNA in Atheromas: Results from a Multicenter Study Applying Standardized Protocols

Size: px
Start display at page:

Download "Reliability of Nested PCR for Detection of Chlamydia pneumoniae DNA in Atheromas: Results from a Multicenter Study Applying Standardized Protocols"

Transcription

1 JOURNAL OF CLINICAL MICROBIOLOGY, Dec. 2002, p Vol. 40, No /02/$ DOI: /JCM Copyright 2002, American Society for Microbiology. All Rights Reserved. Reliability of Nested PCR for Detection of Chlamydia pneumoniae DNA in Atheromas: Results from a Multicenter Study Applying Standardized Protocols Petra Apfalter, 1 * Ojan Assadian, 2 Francesco Blasi, 3 Jens Boman, 4 Charlotte A. Gaydos, 5 Michael Kundi, 6 Athanasios Makristathis, 1 Marion Nehr, 1 Manfred L. Rotter, 1 and Alexander M. Hirschl 1 Division of Clinical Microbiology 1 and Division of Hospital Hygiene, 2 Hygiene-Institute, and Department of Occupational and Social Hygiene, Institute of Environmental Health, 6 University of Vienna, Vienna, Austria; Institute of Respiratory Diseases, University of Milan, IRCCS Policlinico, Milan, Italy 3 ; Department of Clinical Virology, Umeå University Hospital, Umeå, Sweden 4 ; and Department of Medicine, Division of Infectious Diseases, The Johns Hopkins University, Baltimore, Maryland 5 Received 7 March 2002/Returned for modification 13 July 2002/Accepted 12 August 2002 The present multicenter study was designed to find explanations for the discrepancies in the reported rates of detection of Chlamydia pneumoniae DNA in endarterectomy specimens. Coded identical sets of (i) a C. pneumoniae DNA dilution series (panel 1; n 10), (ii) spiked control tissue specimens (panel 2; n 10 specimens, including 5 negative controls), and (iii) endarterectomy specimens (panel 3; 15 atheromas, 5 negative controls) were analyzed at four laboratories by three standardized DNA extraction methods in each laboratory and a nested touchdown PCR protocol targeting the ompa gene of C. pneumoniae. Panel 1 samples were correctly identified as positive to levels of 0.3 inclusion-forming units (IFU)/PCR mixture (100%) and 0.03 IFU/PCR mixture (50%). All negative controls were correctly reported as negative. Panel 2 samples were identified as C. pneumoniae positive to levels of 0.01 IFU/PCR mixture (100%) and IFU/PCR mixture (91%), independent of the DNA extraction method used, and only one false-positive result was reported. For panel 3 samples, 5 of 240 (2%) analyses (in which DNA extractions and PCR were performed at the same laboratory) were positive; the positive specimens were from three endarterectomy specimens and two negative controls. After exchange of DNA extracts between laboratories, 13 of 15 atheroma samples were C. pneumoniae DNA positive in at least 1 of a series of 48 analyses per atheroma sample; however, the overall positivity rate did not exceed 5% (33 of 720 analyses) and therefore was lower than that for the negative controls (8%; 19 of 240 analyses). Not a single positive result could be achieved when all panel 3 extracts (n 240 analyses) were reamplified by a 16S rrna PCR followed by hybridization with a C. pneumoniae-specific probe. Statistical analyses demonstrated that positive results did not occur in an independent and random fashion and could most likely be explained by amplicon carryover at the nested PCR level as well as amplicon introduction during DNA extraction, but not by the patterns of distribution of very low target levels or a certain DNA extraction protocol. The results of studies by nested PCR for detection of the prevalence of C. pneumoniae will always be questionable. * Corresponding author. Mailing address: Department of Clinical Microbiology, Hygiene-Institute, University of Vienna, Vienna University Hospital, Währinger Gürtel 18-20/5P, A-1090 Vienna, Austria, Phone: 43 (1) Fax: 43 (1) Petra.Apfalter@akh-wien.ac.at. During the past decade the association between Chlamydia pneumoniae, an important respiratory pathogen in humans (10, 11), and atherosclerosis (8) has continually been strengthened by direct detection of the organism in atherosclerotic tissues (21). Although there are no standardized PCR protocols, nested PCR has so far been the method most often used for this purpose. However, comparison of the data has been difficult because detection rates have varied considerably by protocol and individual testing center (4, 9, 12, 14 19, 21, 22, 24). Until now no systematic evaluation of various DNA extraction protocols and kits or of PCRs has been conducted for atherosclerotic tissue specimens. It is still not clear if methodological difficulties, a target distribution problem, various C. pneumoniae prevalences in different studies, or all of these factors account for the vast divergence of positive findings. To date only two published studies have compared the results of detection methods conducted at different centers (1, 19). The rates of concordance of positive results in the study organized by Ramirez et al. (19) ranged between 9 and 82%. Since different parts of the atherosclerotic vessels were analyzed in the participating laboratories, a random distribution of C. pneumoniae within the plaques may explain some of the discrepancies. Recently, a multicenter trial was conducted to compare various DNA extraction methods and PCR protocols by using identical specimens (1), but no correlation between the detection rates and the sensitivities of the methods was found. While analyses performed with control tissues spiked with C. pneumoniae constantly showed similar results within the different laboratories, the reported rates of positivity for the atheroma panel varied between 0 and 60%, with the maximum rate of concordance for positive results being only 25% (1). 4428

2 VOL. 40, 2002 NESTED PCR FOR C. PNEUMONIAE DNA DETECTION 4429 As a continuation of that study, the present multicenter study was designed to find explanations for these rather unexpected results by keeping experimental variables to a minimum. This study specifically addresses the following questions. Does the DNA extraction protocol influence the overall rate of positivity for C. pneumoniae in atherosclerotic vessels? Given that the level of the target in a clinical sample is very low, does replicate PCR testing enhance sensitivity and therefore raise the overall positivity rate? Does contamination play a role, and if so, at what step does it occur? MATERIALS AND METHODS Study design. Four laboratories that participated in a previous study (1) received three experimental panels that were numbered by a participant-specific code and that consisted of aliquots of (i) a ready-to-use C. pneumoniae DNA dilution series (panel 1; for determination of the sensitivity of the nested touchdown PCR protocol of Tong and Sillis [23], which targets the ompa gene of C. pneumoniae), (ii) mock-infected control tissue specimens (panel 2; for comparison of the three DNA extraction methods performed independently at each laboratory), and (iii) endarterectomy samples (for extraction of the DNA from each sample at each center by the same three protocols used for panel 2 samples, followed by sharing of DNA among the laboratories and testing for ompa by nested PCR). In addition, the amount of DNA in all 240 panel 3 DNA extracts exchanged among the laboratories (20 samples were prepared at each of the four laboratories, with three DNA extraction methods used per sample) was measured (DyNA-Quant 200 fluorometer; Pharmacia, San Francisco, Calif.) and retested by using primers targeting the 16S rrna gene of C. pneumoniae, followed by dot blot analysis (16) at laboratory A. C. pneumoniae dilution series. Serial dilutions of a frozen chlamydial stock preparation (strain MUL-1; M. Maass, Lübeck, Germany) were cultured in triplicate onto HEp-2 cells (CCL-23; American Type Culture Collection), and infectivity titers were determined 72 h after infection as described previously (20). To obtain purified C. pneumoniae elementary bodies for DNA preparation, stock chlamydiae were purified by differential centrifugation. To determine the corresponding numbers of chlamydial particles by immunofluorescence microscopy, aliquots of chlamydial dilutions were centrifuged onto lysin-coated coverslips. All experiments were done in triplicate. DNA from elementary bodies was extracted as described previously (2) and measured with a DyNA-Quant 200 fluorometer (Pharmacia). Experimental panel 1. Each participant received 10 aliquots (50 l each) of a 10-fold dilution of chlamydial DNA (n 6) and water-containing negative controls (n 4) ready for testing by PCR. The aliquots with DNA contained C. pneumoniae DNA at concentrations ranging from 1.3 g/ml to 13 pg/ml (corresponding to 10 5 to 1 chlamydial particles/ml or to inclusionforming units [IFU]/ml). Experimental panel 2. Each participant received in triplicate 10 aliquots of C. pneumoniae-spiked porcine aortic tissue samples (n 5; containing 10 2,10 1,1, 0.1, and 0.05 IFU [corresponding to to 17.5 particles]/ml of aortic porcine homogenate, respectively) and unspiked (n 5) porcine aortic tissue samples. The porcine aortic tissue samples had been homogenized to 20 mg/ml in Dulbecco s phosphate-buffered saline (Gibco, Life Technologies, Paisley, Scotland) and were prepared as described recently (1). Aliquots of 2 ml each were centrifuged (15,000 g for 30 min) at 4 C, and pellets ready for DNA extraction were stored at 80 C. Experimental panel 3. Frozen ( 80 C) endarterectomy specimens (n 15) obtained from patients with severe atherosclerosis and therefore undergoing vascular surgery (carotid artery, n 8; femoral artery, n 3; aneurysm of the abdominal aorta, n 4) were thawed in one session, decalcified, and homogenized to 20 mg/ml in Dulbecco s phosphate-buffered saline with sterile tissue grinders, vortexed, immediately divided into 2-ml aliquots, centrifuged at 4 C (15,000 g for 30 min), and refrozen as pellets at 80 C. Negative controls (porcine aortic tissue; n 5) were prepared together with those used for panel 2. Thus, each participating laboratory received a total of 60 samples (specimens, n 45; negative controls, n 15; three aliquots of each specimen and control for three different DNA extractions). No mock-infected tissue controls were included in panel 3, and neither the laboratory in which the specimens in the panel were prepared nor the pipettes used to prepare the specimens in the panel had ever been used for C. pneumoniae-related work. Panels 1 and 2 were prepared after the processing of negative controls and clinical specimens in a laminar-flow cabinet in a physically separated room. Experimental panels were stored at 80 C until they were shipped within 48 h on dry ice to the collaborating laboratories. DNA extraction. DNA of identical tissue aliquots (40 mg of tissue for each of panels 2 and 3) were extracted by use of two commercial kits, the High Pure PCR template preparation kit (BM kit; suitable for extraction of DNA from 25 to 50 mg of tissue; Boehringer, Mannheim, Germany) and the QIAmp DNA Mini kit (Q kit; tissue protocol adjusted to 40 mg; Qiagen, Chatsworth, Calif.), according to the instructions of the manufacturers. DNA was also extracted by a conventional proteinase K phenol-chloroform protocol (K protocol) (2). The DNA was eluted or dissolved in a volume of 200 l and divided into four 50- l aliquots. One aliquot was tested by PCR at the same laboratory where the DNA extraction was performed, and the other three aliquots were sent to the other laboratories for analysis by PCR. PCR. Each laboratory used identical amounts of template for PCR analysis: 10 l of template (2 mg of tissue)/50 l offirst-round PCR mixture and 1 l of amplicon/50 l of the PCR mixture for the nested PCR step. Otherwise, the PCRs as well as the cycling conditions were as described previously (23). To check for the presence of PCR inhibitors that may have been present in the atheroma panel, all panel 3 DNA extracts prepared in each laboratory (60 at each laboratory) were run in duplicate; the samples tested were unspiked or spiked with C. pneumoniae DNA in an amount corresponding to that from about one to five elementary bodies. In case of inhibition the study protocol recommended retesting of a 1:10 dilution of the original DNA extract. The nested PCR products were separated by electrophoresis in 3% agarose gels at 80 V/h by using Tris-borate-EDTA buffer (ph 8.3) and were visualized with ethidium bromide. Negative results were considered or reported as true negative only if the DNA in the corresponding spiked sample could be amplified, all extraction-negative as well as in-house negative controls tested negative, and the positive controls (which contained the same small amount of C. pneumoniae DNA used to spike the samples) tested positive. The presence of amplicons 207 bp in length was considered a positive result for C. pneumoniae if all controls reacted as expected. To minimize the risk of contamination, DNA extraction, PCR amplification, and electrophoresis were performed in separate rooms in all four laboratories. Each room had its own UV hood and set of pipettes, gloves, and disposable racks; and aerosol-resistant pipette tips were used. All reagents used were subdivided into small aliquots for each PCR run. Furthermore, the surface of every tube containing foreign panel 3 DNA extracts was decontaminated with sodium hypochlorite prior to handling in the area where PCR was carried out in each laboratory. To further avoid contamination, samples were always handled in the following order: clinical specimens (including the five blindly matched negative controls) as well as extraction-negative controls at every second position, inhouse water containing negative controls at each fifth position for the first and nested PCRs, spiked specimens, in-house negative control, master mix control, and positive control. The same procedure had to be followed throughout the nested PCR setup. Statistical analysis. The purpose of the statistical analysis was to analyze the distribution of positive results for negative controls and atheromas across different combinations of laboratories, PCR extractions, and amplification (panel 3). For every such combination a series of 5 negative controls and 15 atheroma samples was available. Therefore, the probability of observing k positive results among n samples tested (n 5 and 15, respectively) is given by a binomial distribution, provided the probability for a positive result is constant and independent for each sample (i.e., provided that the probability of contamination is constant over all laboratories, DNA extractions, and the amplification assay for the negative samples and that the joint probability of detection of chlamydial DNA and contamination is constant for atheroma samples). Comparisons of the observed and expected distributions of positive results were done by Pearson s chi-square goodness-of-fit test. RESULTS Panel 1. The results for a blindly tested DNA dilution series are shown in Table 1. All four laboratories (100%) identified the C. pneumoniae DNA-containing controls as positive to a level of IFU/ml ( IFU/PCR mixture), and two laboratories (50%) detected 3 IFU/ml ( IFU/PCR mixture). All analyses (n 16) of the water-containing negative controls (n 4) had a negative result in all laboratories (100%).

3 4430 APFALTER ET AL. J. CLIN. MICROBIOL. TABLE 1. Detection of C. pneumoniae DNA in a ready-to-use dilution series in four laboratories Sample Amt of chlamydiae/pcr mixture a PCR result b by laboratory IFU EBs c Amt of DNA A B C D S1 30 1, ng S S pg S S pg S S pg S S fg S fg a Amount of chlamydiae (IFU corresponding to elementary bodies or DNA) in a 10- l amplified DNA extract/50 l offirst-round PCR mixture. b, reported as C. pneumoniae positive by nested PCR;, reported as C. pneumoniae negative by nested PCR. c EBs, elementary bodies. TABLE 2. Detection of C. pneumoniae in aliquots of porcine aortic tissue samples in four laboratories by three different DNA extraction protocols Sample Amt of chlamydiae/pcr mixture a IFU PCR result by the following DNA extraction protocol for the indicated laboratory c BM kit Q kit K protocol EBs b A B C D A B C D A B C D S1 10 3,500 S2 0 0 S S4 0 0 S S6 0 0 S S8 0 0 S S a Amount of chlamydiae (numbers of IFU corresponding to numbers of elementary bodies) in a 10- l amplified DNA extract/50 l offirst-round PCR mixture. b EBs, elementary bodies. c, reported as C. pneumoniae positive by nested PCR;, reported as C. pneumoniae negative by nested PCR. TABLE 3. Clinical evaluation of three different DNA extraction protocols for detection of C. pneumoniae DNA in endarterectomy specimens a Sample b Atheroma (n 15) Negative control (n 5) C. pneumoniae positive PCR results by the following DNA extraction protocol for the indicated laboratory: BM kit Q kit K protocol A B C D A B C D A B C D c d c a The PCR results reported from the four laboratories are for DNA extracts exclusively prepared in each laboratory. b An endarterectomy specimen or porcine aortic tissue (negative controls) was reported as C. pneumoniae positive when extracts prepared in each laboratory were tested by PCR. c Concordant results for two endarterectomy specimens (arteria carotis and arteria femoralis). d Endarterectomy specimen (arteria femoral) different from the arteria femoralis described in note c. Panel 2. C. pneumoniae-spiked tissue samples (n 5; three aliquots of each sample) and unspiked tissue samples (n 5; three aliquots of each sample) were analyzed, and the results are shown in Table 2. By use of the BM kit all four laboratories (100%) identified the spiked samples as positive to 0.5 IFU/ml (0.005 IFU/PCR mixture). Nineteen of 20 analyses of the negative controls (n 5) were reported as negative (95%). By use of the Q kit, three laboratories (75%) identified the samples spiked with C. pneumoniae as positive to 0.5 IFU/ml (0.005 IFU/PCR mixture), and 1 laboratory identified the spiked samples as positive to 1 IFU/ml (0.01 IFU/PCR mixture). All 20 analyses of the negative controls (n 5) had negative results (100%). By the noncommercially available K protocol, one laboratory failed to detect C. pneumoniae in any of the spiked control tissues, and the other three laboratories identified C. pneumoniae in the samples spiked with C. pneumoniae as positive to 0.5 IFU/ml (0.005 IFU/PCR mixture). The results for all negative controls (100%) were reported as negative. Panel 3. Clinical evaluation. Table 3 displays only the PCR results obtained with the DNA extracts prepared in each laboratory. Of a total of 240 analyses (180 analyses with 15 endarterectomy specimens and 60 analyses with 5 negative controls), 7 (3%) were reported to be positive for C. pneumoniae: 5 positive analyses (2%) stemmed from 3 endarterectomy specimens (for laboratory C, concordant results for one arteria carotis specimen and one arteria femoralis specimen with the BM kit and by the K protocol; for laboratory D, one positive arteria femoralis specimen with the Q kit;) and 2 (0.8%) stemmed from negative controls (for laboratory C, BM kit). Laboratories A and B did not report any positive results from their own atheroma extracts and identified all negative controls as negative. Subsequently, DNA extracts (three extracts per sample per laboratory) were exchanged among the four laboratories, and the PCR results are summarized in Table 4. Taken together, each sample was analyzed 48 times (12 DNA extracts per sample tested by PCR at four laboratories each; in summary, 960 analyses [720 and 240 analyses from supposedly identical aliquots of 15 endarterectomy samples and 5 negative controls, respectively]). In summary, 33 of 720 analyses (5%) of endarterectomy specimens were positive for C. pneumoniae, but none of them was positive by more than 5 of 48 analyses, showing a concordant result for positivity of only 10%. At least 1 of 48 analyses reported a positive result for 13 endarterectomy specimens (86%). Only two atheromas were reported to be negative by all 48 analyses. Compared to the results for the endarterectomy specimens, the ratio of positivity was greater for the negative controls (19 of 240; 8%) with at least 2 of 48 analyses reporting positive results for all five negative controls. Considering the different DNA extraction methods, the distributions of positive results for C. pneumoniae were as follows: for the BM kit, 22 of 240 (9%) endarterectomy samples and 11 of 80 (14%) negative controls; for the Q kit, 5 of 240 (2%) endarterectomy samples and 5 of 80 (6%) negative controls; for the K protocol, 6 of 240 (3%) endarterectomy samples and

4 VOL. 40, 2002 NESTED PCR FOR C. PNEUMONIAE DNA DETECTION 4431 a Each sample was tested by PCR 48 times, with a total of 960 analyses performed: 720 and 240 analyses with identical aliquots from 15 endarterectomy samples and 5 negative controls, respectively. Negative control (n 5) Atheroma (n 15) A B C D A B C D A B C D A B C D A B C D A B C D A B C D A B C D A B C D A B C D A B C D A B C D BM Q K BM Q K BM Q K BM Q K Panel 3 sample laboratory A laboratory B laboratory C laboratory D C. pneumoniae-positive PCR results by method and laboratory for: TABLE 4. Clinical evaluation of three different DNA extraction protocols for detection of C. pneumoniae DNA in endarterectomy specimens after exchange of DNA extracts among four laboratories (laboratories A to D) a TABLE 5. Overall C. pneumoniae positivity rates for endarterectomy samples (panel 3) and negative controls reported by each laboratory (laboratories A to D) by the origin of the DNA extracts tested and the DNA extraction protocol used Laboratory Total no. of positive a analyses positive b atheromas falsepositives analyses c positive analyses (origin d of extracts) Atheroma Negative controls c DNA extraction method or protocol used A (C) BM 2 (C) 1 (C) K B (C) 2 (C) BM 2 (C) 1 (C) K C (A) 1 (A) BM 1 (B) 1 (B) BM 2 (C) 2 (C) BM 1 (D) 1 (D) BM 2 (A) 1 (A) Q 2 (B) Q 2 (C) K D (A) 1 (A) BM 4 (C) 3 (C) BM 3 (A) Q 1 (C) Q 1 (D) Q 1 (C) K a Number of samples reported as C. pneumoniae DNA positive of a total of 960 analyses. b Number of endatherectomy specimens reported as C. pneumoniae DNA positive of a total of 720 analyses. c Porcine aortic tissue samples (negative controls) reported as C. pneumoniae DNA positive of a total of 240 analyses. d DNA was extracted at laboratory A, B, C, or D. 3 of 80 (4%) negative controls. Table 5 shows the overall positivity ratio achieved by each laboratory in the context of the origins of the DNA extracts. All 240 exchanged panel 3 DNA extracts retested at laboratory A by a 16S rrna nested PCR (for laboratory H, the detection limit for spiked vascular tissue samples was 1 elementary body/pcr mixture [1]) followed by dot blot hybridization were negative for C. pneumoniae DNA. The mean DNA contents of these extracts measured at laboratory A were 0.12, 0.11, 0.04, and 0.07 g/ l for laboratories A, B, C, and D, respectively. With respect to the various DNA extraction methods, the mean DNA content in extracts obtained with the BM kit was 0.11 g/ l (range of mean values, to 0.19 g/ lat laboratories C and A, respectively), the mean DNA content in extracts obtained with the Q kit was 0.11 g/ l (range of mean values, to 0.15 g/ l at laboratories C and A [and laboratory B], respectively), and the mean DNA content in extracts obtained by the K protocol was 0.03 g/ l (range of mean values, to 0.04 g/ l at laboratories C and D, respectively). Statistics. Analysis of the frequency distribution of positive results for negative controls, assuming a contamination probability of 8% (the results for negative controls reported as positive), and comparison with the binomial revealed a goodness-of-fit chi-square statistic of 3.08 (2 degrees of freedom [df]), which was almost significant (P 0.215). Under the assumption of constancy of contamination probability and independence, among the five negative controls tested there

5 4432 APFALTER ET AL. J. CLIN. MICROBIOL. were slightly too many series with no positive results and too few with just one positive result. For the endarterectomy samples, however, the deviation from the binomial distribution was highly significant (chi-square 11.99; df 3; P 0.007). In particular, the probability (under the assumption of constancy and independence) that more than five positive atheroma specimens would be observed among 15 atheroma specimens is 3 to 100,000 given the overall rate of positivity (5%). Note that one of the series had 11 positive specimens. From these results the assumption of constancy and independence of positive specimens can be refuted. Thus, the observation of a positive result does not occur in an independent and random fashion. If this had been due to the presence of chlamydial DNA in some of the samples but not in others, the frequency distribution of positive results for the 15 specimens across the 48 tests performed should likewise have deviated from the binomial. However, this was not the case (chi-square 2.589; df 4; P 0.629). DISCUSSION This study was originally undertaken because the demand for a standardized PCR assay for the detection of C. pneumoniae from clinical specimens has evolved in recent years (5, 7). Hence, four laboratories applied the nested PCR of Tong and Sillis (23) to DNA extracts prepared by different extraction methods under standardized conditions and also interchanged DNA extracts. The PCR results of the present study achieved with purified C. pneumoniae DNA were uniform, highly sensitive (0.3 to 0.03 IFU/PCR mixture), specific, and reproducible at a very low target level at each laboratory and therefore allowed the direct comparison of the three DNA extraction protocols applied to mock-infected controls. With the exception of the in-house K protocol and one false-positive result at laboratory D, even lower detection limits (0.005 IFU/PCR mixture) were reported for the mock-infected controls. It could be that the presence of tissue DNA acted as a carrier and increased the total yield of the C. pneumoniae targets. However, the results for the endarterectomy samples are not altogether unexpected considering the results of the previous study (1), but they are nevertheless disappointing. If the focus is exclusively on data derived from analyses done with extracts prepared by each laboratory (Table 3), only 7 (3%) of 240 analyses reported positive results for C. pneumoniae: laboratory C reported four positive results (2%) for two endarterectomy specimens (specimens 3 and 14) but two false-positive results for negative controls as well, and laboratory D found specimen 2 to be positive with the Q kit. Laboratories A and B did not report any positive results from the atheroma extracts that they prepared in their own laboratories and identified all negative controls as negative. In light of the false-positive results obtained with negative controls at laboratory C, none of these positive results for endarterectomy specimens should be considered valid. After exchange of extracts, at least 1 of 48 analyses was positive for 13 endarterectomy specimens (86%), a finding which could be in accordance with the fact that the target level was extremely low, but the distribution of positive findings did not follow a random distribution (even if the calculation was done with a background false-positivity rate of 8%). Therefore, an interpretation that nearly 90% of the specimens were positive (e.g., at a very low level) is not very convincing and is statistically very unlikely, although much higher PCR positivity rates have been published for specimens with low levels of target DNA, such as atherosclerotic tissues and peripheral blood mononuclear cells with only triplicate or even no repetitive testing at all (3, 4, 6, 12 14, 17, 25). Again, in this study the deviation of the number of positive results from the binomial distribution within each combination of laboratory, PCR extraction, and PCR amplification could have been because some specimens were truly positive. However, in this case the distribution calculated over specimens should also deviate from a binomial distribution. This was definitely not the case. Therefore, positivity is much more likely due to other factors than the presence of C. pneumoniae DNA in atheromas in the present study. Contamination, especially amplicon carryover in the nested PCR, is known to be an insidious problem, and it is possible that the literature in the field is biased by false-positive PCR results. This and the fact that studies with negative findings are less likely to be published could bias conclusions drawn from systematic reviews and meta-analyses. In the present study, only two atheroma samples (from 48 analyses) were reported to be completely negative, which was not true for the negative controls, with a minimum of two analyses per 48 testing attempts reporting positive results for all five negative controls. Importantly, the positivity rate was even higher for negative controls than for endarterectomy samples. It is obvious that there was a contamination problem, but where and at what step did it occur? The only laboratory that reported false-positive results at a time when no foreign extracts had been tested was laboratory C, and most but not all positive findings stemmed from extracts provided from that laboratory (34 of 52 analyses [65%]; Table 5); e.g., all 16 analyses with positive results reported by laboratory B stemmed from extracts prepared at laboratory C. On the other hand, laboratory C itself reported a lower positivity rate, and laboratory A reported only a single positive specimen among the same extracts. The occurrence of amplicon carryover at laboratory B during nested PCR could also explain the 13 positive samples tested in a series (Table 4). Anyhow, occurrences of contamination seem to be randomly dispersed among the results at a frequency below 2%, and cases of clustered contamination were detected in which almost all samples tested were positive. This points to a heterogeneity of contamination, with the most critical steps throughout the whole procedure being the nested step of the PCR itself as well as ompa amplicon introduction during DNA extraction. The fact that not a single positive sample could be detected when the extracts were retested by a PCR assay targeting a different gene (with the same detection limit for C. pneumoniae DNA for this kind of specimen) further supports the hypothesis of ompa amplicon contamination, as does the overall distribution of positive findings for laboratory C itself and laboratory D (Table 5). Ong et al. (18) associated the high numbers of positive findings in the previous study (1) with the application of the BM kit (whose use requires a large number of manipulation steps, resulting in a high rate of false-positive results). However, we are of the opinion that the choice of DNA extraction

6 VOL. 40, 2002 NESTED PCR FOR C. PNEUMONIAE DNA DETECTION 4433 kit is of minor importance. The Q kit, e.g., requires as many manipulation steps as the BM kit (six spin steps and opening of vials on 11 occasions until elution of DNA), but only a few or even no positive results were achieved with that kit in the present study and the previous study (1) as well as in the study conducted by Ong et al. (18). In addition, in the present study both kits recovered similar amounts of DNA, and although laboratory C especially appeared to be more efficient in recovering DNA with the BM kit, these extracts revealed the smallest amounts of DNA compared to the amounts detected by the other laboratories when they used the BM kit. In this study experienced laboratories obviously had problems with contamination. It stands to reason that all four laboratories performed DNA extraction, first and nested PCR amplifications, and electrophoresis in separate rooms equipped with their own UV hoods, sets of pipettes, disposable racks, and aerosol-resistant pipette tips. Furthermore, all participants were requested to decontaminate tubes containing external foreign DNA before they opened the tubes and performed PCR at each laboratory and to include additional water-containing negative controls in the first PCR and at the nested PCR level as well as negative controls following the whole DNA extraction procedure. Since the ompa PCR assay applied in the present study consisted of a nested step, inactivation of the first PCR product (containing dutp instead of dttp) by the enzyme uracil N-glycosylase as well as isopsoralen treatment could not be performed, since both methods would have destroyed the template for the nested PCR step. Anyhow, all attempts were used to reduce contamination, and PCR results were reported only if all in-house negative controls as well as positive controls reacted as expected; however, contamination did happen and came to light only because of the study design. These data demonstrate the limits of nested PCR, which might be necessary for detection of an organism assumed to be present only at a very low level but whose use is connected with a high risk of contamination. As long as methods like nested PCR are used, we recommend that several negative control tissue samples always be included for each specimen analyzed. Control samples should contain enough carrier DNA to detect low-level amplicon carryover and should be used instead of negative controls containing water only, and controls must be used throughout the procedure, from DNA extraction to detection of the PCR product. By this procedure contamination can at least be identified immediately. In addition, external quality control should be aimed at every laboratory performing nested PCR on clinical samples. Furthermore, repeated analyses (including repeated DNA extractions) can be performed to further increase specificity. However, the drawback of this procedure is that it is labor intensive and expensive. Therefore, alternative highly sensitive methods such as real-time PCR should be established on a commercial basis as soon as possible because they are less prone to contamination and, in addition, allow target quantification. The main conclusion of the present study is that although the intention was to control the methodology as best as possible, the question of cross-contamination remains whenever a nested PCR is performed. In this sense, the results of studies that use nested PCR to determine the prevalence of C. pneumoniae will always be questionable. REFERENCES 1. Apfalter, P., F. Blasi, J. Boman, C. A. Gaydos, M. Kundi, M. Maass, A. Makristathis, A. Meijer, R. Nadrchal, K. Persson, M. L. Rotter, C. Y. W. Tong, G. Stanek, and A. M. Hirschl Multicenter comparison trial of DNA extraction methods and PCR assays for detection of Chlamydia pneumoniae in endarterectomy specimens. J. Clin. Microbiol. 39: Ausubel, F. M., R. Breut, R. E. Kingston, D. D. Moore, J. G. Seidman, J. A. Smith, and K. Struhl (ed.) Preparation of genomic DNA from bacteria, p In Current protocols in molecular biology. John Wiley & Sons, Inc., New York, N.Y. 3. Blasi, F., J. Boman, G. Esposito, G. Melissano, R. Chiesa, R. Cosentini, P. Tarsia, Y. Tshomba, M. Betti, M. Alessi, N. Morelli, and L. Allegra Chlamydia pneumoniae DNA detection in peripheral blood mononuclear cells is predictive of vascular infection. J. Infect. Dis. 180: Blasi, F., F. Denti, M. Erba, R. Cosentini, R. Raccanelli, A. Rinaldi, L. Fagetti, G. Esposito, U. Roberti, and L. Allegra Detection of Chlamydia pneumoniae but not Helicobacter pylori in atherosclerotic plaques of aortic aneurysms. J. Clin. Microbiol. 34: Boman, J., and M. Hammerschlag Chlamydia pneumoniae and atherosclerosis: critical assessment of diagnostic methods and relevance to treatment studies. Clin. Microbiol. Rev. 15: Boman, J., S. Söderberg, J. Forsberg, L. S. Birgander, A. Allard, K. Persson, E. Jidell, U. Kumlin, P. Juto, A. Waldenström, and G. Wadell High prevalence of Chlamydia pneumoniae DNA in peripheral blood mononuclear cells in patients with cardiovascular disease and in middle-aged blood donors. J. Infect. Dis. 178: Dowell, S. F., R. W. Peeling, J. Boman, G. M. Carlone, B. S. Fields, J. Guarner, M. R. Hammerschlag, L. A. Jackson, C. C. Kuo, M. Maass, T. O. Messmer, D. F. Talkington, M. L. Tondella, S. R. Zaki, and the Chlamydia pneumoniae Workshop Participants Standardizing Chlamydia pneumoniae assays: recommendations from the Centers for Disease Control and Prevention (USA) and the Laboratory Centre for Disease Control (Canada). Clin. Infect. Dis. 33: Grayston, J. T Background and current knowledge of Chlamydia pneumoniae and atherosclerosis. J. Infect. Dis. 181(Suppl. 3):S402 S Jantos, C. A., A. Nesseler, W. Waas, W. Baumgärtner, H. Tillmanns, and W. Haberbosch Low prevalence of Chlamydia pneumoniae in atherectomy specimens from patients with coronary heart disease. Clin. Infect. Dis. 28: Kauppinen, M., and P. Saikku Pneumonia due to Chlamydia pneumoniae: prevalence, clinical features, diagnosis and treatment. Clin. Infect. Dis. 21:S244 S Kuo, C. C., L. A. Jackson, L. A. Campbell, and J. T. Grayston Chlamydia pneumoniae (TWAR). Clin. Microbiol. Rev. 8: Kuo, C. C., A. Shor, L. A. Campbell, H. Fukushi, D. L. Patton, and J. T. Grayston Demonstration of Chlamydia pneumoniae in atherosclerotic lesions of coronary arteries. J. Infect. Dis. 167: Maass, M., C. Bartels, P. M. Engel, U. Mamat, and H. H. Sievers Endovascular presence of viable Chlamydia pneumoniae is a common phenomenon in coronary artery disease. J. Am. Coll. Cardiol. 31: Maass, M., E. Krause, P. M. Engel, and S. Krüger Endovascular presence of Chlamydia pneumoniae in patients with hemodynamically effective carotid artery stenosis. Angiology 8: Meijer, A., J. A. van der Vliet, P. J. M. Roholl, S. K. Gielis-Proper, A. de Vries, and J. M. Ossewaarde Chlamydia pneumoniae in abdominal aortic aneurysms abundance of membrane components in the absence of heat shock protein 60 and DNA. Arterioscler. Thromb. Vasc. Biol. 19: Nadrchal, R., A. Makristathis, P. Apfalter, M. Rotter, W. Trubel, I. Huk, P. Polterauer, and A. M. Hirschl Detection of Chlamydia pneumoniae DNA in atheromatous tissues by polymerase chain reaction. Wien. Klin. Wochenschr. 111: Ong, G., B. J. Thomas, A. O. Mansfield, B. R. Davidson, and D. Taylor- Robinson Detection and widespread distribution of Chlamydia pneumoniae in the vascular system and its possible implications. J. Clin. Pathol. 49: Ong, G. M., P. V. Coyle, A. A. B. Barros D Sa, W. G. McCluggage, W. P. Duprex, H. J. O Neill, D. E. Wyatt, K. B. Bamford, B. O Loughlin, and C. McCaughey Non-detection of Chlamydia species in arotid atheroma using generic primers by nested PCR in a population with a high prevalence of Chlamydia pneumoniae antibody. BMC Infect. Dis. 1:12. [Online.] 19. Ramirez, J. A., and the Chlamydia pneumoniae/atherosclerosis Study Group Isolation of Chlamydia pneumoniae from the coronary artery of a patient with coronary atherosclerosis. Ann. Intern. Med. 125: Roblin, M. R., W. Dumornay, and M. R. Hammerschlag Use of HEp-2 cells for improved isolation and passage of Chlamydia pneumoniae. J. Clin. Microbiol. 30: Taylor-Robinson, D., and B. J. Thomas Chlamydia pneumoniae in atherosclerotic tissue. J. Infect. Dis. 181(Suppl. 3):S437 S Thomas, M., Y. Wong, D. Thomas, M. Ajaz, V. Tsang, P. J. Gallaher, and

7 4434 APFALTER ET AL. J. CLIN. MICROBIOL. M. E. Ward Relation between direct detection of Chlamydia pneumoniae DNA in human coronary arteries at postmortem examination and histological severity (Stary grading) of associated atherosclerotic plaque. Circulation 99: Tong, C. Y. W., and M. Sillis Detection of Chlamydia pneumoniae and Chlamydia psittaci in sputum samples by PCR. J. Clin. Pathol. 46: Weiss, S. M., P. M. Roblin, C. A. Gaydos, P. Cummings, D. L. Patton, N. Schulhoff, J. Shani, R. Frankel, K. Penney, T. C. Quinn, M. R. Hammerschlag, and J. Schachter Failure to detect Chlamydia pneumoniae in coronary atheromas of patients undergoing atherectomy. J. Infect. Dis. 173: Wong, Y., K. D. Dawkins, and M. E. Ward Circulating Chlamydia pneumoniae DNA as a predictor of coronary artery disease. J. Am. Coll. Cardiol. 34:

Multicenter Comparison Trial of DNA Extraction Methods and PCR Assays for Detection of Chlamydia pneumoniae in Endarterectomy Specimens

Multicenter Comparison Trial of DNA Extraction Methods and PCR Assays for Detection of Chlamydia pneumoniae in Endarterectomy Specimens JOURNAL OF CLINICAL MICROBIOLOGY, Feb. 2001, p. 519 524 Vol. 39, No. 2 0095-1137/01/$04.00 0 DOI: 10.1128/JCM.39.2.519 524.2001 Copyright 2001, American Society for Microbiology. All Rights Reserved. Multicenter

More information

Product # Kit Components

Product # Kit Components 3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: (905) 227-8848 Fax: (905) 227-1061 Email: techsupport@norgenbiotek.com Pneumocystis jirovecii PCR Kit Product # 42820 Product Insert Background Information

More information

Besides conventional risk factors, inflammation seems to

Besides conventional risk factors, inflammation seems to No Evidence of Involvement of Chlamydia pneumoniae in Severe Cerebrovascular Atherosclerosis by Means of Quantitative Real-Time Polymerase Chain Reaction Petra Apfalter, MD; Wolfgang Barousch, BSc; Marion

More information

Kit Components Product # EP42720 (24 preps) MDx 2X PCR Master Mix 350 µl Cryptococcus neoformans Primer Mix 70 µl Cryptococcus neoformans Positive

Kit Components Product # EP42720 (24 preps) MDx 2X PCR Master Mix 350 µl Cryptococcus neoformans Primer Mix 70 µl Cryptococcus neoformans Positive 3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: techsupport@norgenbiotek.com Cryptococcus neoformans End-Point PCR Kit Product# EP42720 Product

More information

Norgen s HIV proviral DNA PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad icycler

Norgen s HIV proviral DNA PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad icycler 3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: (905) 227-8848 Fax: (905) 227-1061 Email: techsupport@norgenbiotek.com HIV Proviral DNA PCR Kit Product # 33840 Product Insert Background Information

More information

Chlamydia pneumoniae DNA in the Arterial Wall of Patients with Peripheral Vascular Disease

Chlamydia pneumoniae DNA in the Arterial Wall of Patients with Peripheral Vascular Disease Infection Clinical and Epidemiological Study Chlamydia pneumoniae DNA in the Arterial Wall of Patients with Peripheral Vascular Disease J. Gutiérrez, J. Linares-Palomino, C. Lopez-Espada, M. Rodríguez,

More information

Norgen s HIV Proviral DNA PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad T1000 Cycler

Norgen s HIV Proviral DNA PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad T1000 Cycler 3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: techsupport@norgenbiotek.com HIV Proviral DNA PCR Kit Product# 33840 Product Insert Intended

More information

Cytomegalovirus (CMV) End-Point PCR Kit Product# EP36300

Cytomegalovirus (CMV) End-Point PCR Kit Product# EP36300 3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: techsupport@norgenbiotek.com Cytomegalovirus (CMV) End-Point PCR Kit Product# EP36300 Product

More information

Effect of Azithromycin plus Rifampin versus That of Azithromycin Alone on the Eradication of Chlamydia pneumoniae

Effect of Azithromycin plus Rifampin versus That of Azithromycin Alone on the Eradication of Chlamydia pneumoniae Antimicrobial Agents and Chemotherapy, June 1999, p. 1491-1493, Vol. 43, No. 6 0066-4804/99/$04.00+0 Copyright 1999, American Society for Microbiology. All rights reserved. Effect of Azithromycin plus

More information

Chlamydia pneumoniae Eradication from Carotid Plaques. Results of an Open, Randomised Treatment Study

Chlamydia pneumoniae Eradication from Carotid Plaques. Results of an Open, Randomised Treatment Study Eur J Vasc Endovasc Surg 18, 355 359 (1999) Article No. ejvs.1999.0915 Chlamydia pneumoniae Eradication from Carotid Plaques. Results of an Open, Randomised Treatment Study G. Melissano 1, F. Blasi 2,

More information

ABIOpure TM Viral (version 2.0)

ABIOpure TM Viral (version 2.0) ABIOpure TM Viral (version 2.0) DNA/RNA Extraction Handbook Cat No: M561VT50 FOR RESEARCH USE ONLY Table of Contents Contents Page Kit Components 3 Precautions 3 Stability & Storage 4 General Description

More information

JOURNAL OF CLINICAL MICROBIOLOGY, July 2000, p Vol. 38, No. 7. Copyright 2000, American Society for Microbiology. All Rights Reserved.

JOURNAL OF CLINICAL MICROBIOLOGY, July 2000, p Vol. 38, No. 7. Copyright 2000, American Society for Microbiology. All Rights Reserved. JOURNAL OF CLINICAL MICROBIOLOGY, July 2000, p. 2622 2627 Vol. 38, No. 7 0095-1137/00/$04.00 0 Copyright 2000, American Society for Microbiology. All Rights Reserved. Analytical Sensitivity, Reproducibility

More information

A positive association of peripheral arterial occlusive disease (PAD) and Chlamydophila (Clamydia) pneumoniae

A positive association of peripheral arterial occlusive disease (PAD) and Chlamydophila (Clamydia) pneumoniae J. Basic Microbiol. 45 (2005) 4, 294 300 DOI: 10.1002/jobm.200410501 (Departments of Microbiology and Surgery 1, University Hospital San Cecilio, University of Granada; Laboratorio Vircell 2 ; Granada,

More information

Urine - Based XMRV RT-PCR Detection Kit Product # 34700

Urine - Based XMRV RT-PCR Detection Kit Product # 34700 3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: techsupport@norgenbiotek.com Urine - Based XMRV RT-PCR Detection Kit Product # 34700 Product

More information

HIV-1 Viral Load Real Time (RG)

HIV-1 Viral Load Real Time (RG) -1 Viral Load Real Time (RG) Real Time RT-PCR type 1 RNA quantification assay MSP Reg. pending Valdense 3616. 11700. Montevideo. Uruguay. phone (598) 2 336 83 01. Fax (598) 2 336 71 60. Info@atgen.com.uy

More information

Pneumocystis Carinii Real Time PCR Kit. For In Vitro Diagnostic Use Only User Manual

Pneumocystis Carinii Real Time PCR Kit. For In Vitro Diagnostic Use Only User Manual Revision No.: ZJ0003 Issue Date: Aug 7 th, 2008 Pneumocystis Carinii Real Time PCR Kit Cat. No.: QD-0082-02 For use with ABI Prism 7000/7300/7500/7900; Smart CyclerII; icycler iq 4/iQ 5; Rotor Gene 2000/3000;

More information

Microsart Calibration Reagent

Microsart Calibration Reagent Instructions for Use Microsart Calibration Reagent Prod. No. SMB95-2021 Mycoplasma arginini Prod. No. SMB95-2022 Mycoplasma orale Prod. No. SMB95-2023 Mycoplasma gallisepticum Prod. No. SMB95-2024 Mycoplasma

More information

Development and Evaluation of Real-Time PCR-Based Fluorescence Assays for Detection of Chlamydia pneumoniae

Development and Evaluation of Real-Time PCR-Based Fluorescence Assays for Detection of Chlamydia pneumoniae JOURNAL OF CLINICAL MICROBIOLOGY, Feb. 2002, p. 575 583 Vol. 40, No. 2 0095-1137/02/$04.00 0 DOI: 10.1128/JCM.40.2.575 583.2002 Copyright 2002, American Society for Microbiology. All Rights Reserved. Development

More information

Single Cell Quantitative Polymer Chain Reaction (sc-qpcr)

Single Cell Quantitative Polymer Chain Reaction (sc-qpcr) Single Cell Quantitative Polymer Chain Reaction (sc-qpcr) Analyzing gene expression profiles from a bulk population of cells provides an average profile which may obscure important biological differences

More information

RealLine Mycoplasma genitalium Str-Format

RealLine Mycoplasma genitalium Str-Format Instructions for use ASSAY KIT FOR THE QUALITATIVE DETECTION OF MYCOPLASMA GENITALIUM DNA BY REAL-TIME PCR METHOD In vitro Diagnostics () VBD4396 96 Tests valid from December 2018 Rev06_1218_EN Page 1

More information

Leukemia BCR-ABL Fusion Gene Real Time RT-PCR Kit

Leukemia BCR-ABL Fusion Gene Real Time RT-PCR Kit Revision No.: ZJ0003 Issue Date: Aug 7 th, 2008 Leukemia BCR-ABL Fusion Gene Real Time RT-PCR Kit Cat. No.: TR-0126-02 For use with ABI Prism 7000/7300/7500/7900(96 well); Smart Cycler II; icycler iq 4/iQ

More information

Endovascular Presence of Viable Chlamydia pneumoniae Is a Common Phenomenon in Coronary Artery Disease

Endovascular Presence of Viable Chlamydia pneumoniae Is a Common Phenomenon in Coronary Artery Disease JACC Vol. 31, No. 4 March 15, 1998:827 32 827 CORONARY ARTERY DISEASE Endovascular Presence of Viable Chlamydia pneumoniae Is a Common Phenomenon in Coronary Artery Disease MATTHIAS MAASS, MD, CLAUS BARTELS,

More information

MINIREVIEW. Molecular Diagnosis of Chlamydia pneumoniae Infection

MINIREVIEW. Molecular Diagnosis of Chlamydia pneumoniae Infection JOURNAL OF CLINICAL MICROBIOLOGY, Dec. 1999, p. 3791 3799 Vol. 37, No. 12 0095-1137/99/$04.00 0 Copyright 1999, American Society for Microbiology. All Rights Reserved. MINIREVIEW Molecular Diagnosis of

More information

Roche Molecular Biochemicals Application Note No. HP 1/1999

Roche Molecular Biochemicals Application Note No. HP 1/1999 Roche Molecular Biochemicals Application Note No. HP 1/1999 Nucleic Acid Purification High Pure Viral Nucleic Acid Kit High Pure 16 System Viral Nucleic Acid Kit Efficiency of Hepatitis C Virus sample

More information

For in vitro Veterinary Diagnostics only. Kylt Rotavirus A. Real-Time RT-PCR Detection.

For in vitro Veterinary Diagnostics only. Kylt Rotavirus A. Real-Time RT-PCR Detection. For in vitro Veterinary Diagnostics only. Kylt Rotavirus A Real-Time RT-PCR Detection www.kylt.eu DIRECTION FOR USE Kylt Rotavirus A Real-Time RT-PCR Detection A. General Kylt Rotavirus A products are

More information

Recommended laboratory tests to identify influenza A/H5 virus in specimens from patients with an influenza-like illness

Recommended laboratory tests to identify influenza A/H5 virus in specimens from patients with an influenza-like illness World Health Organization Recommended laboratory tests to identify influenza A/H5 virus in specimens from patients with an influenza-like illness General information Highly pathogenic avian influenza (HPAI)

More information

AmoyDx TM BRAF V600E Mutation Detection Kit

AmoyDx TM BRAF V600E Mutation Detection Kit AmoyDx TM BRAF V600E Mutation Detection Kit Detection of V600E mutation in the BRAF oncogene Instructions For Use Instructions Version: B3.1 Date of Revision: April 2012 Store at -20±2 o C 1/5 Background

More information

Hepatitis B Virus Genemer

Hepatitis B Virus Genemer Product Manual Hepatitis B Virus Genemer Primer Pair for amplification of HBV Viral Specific Fragment Catalog No.: 60-2007-10 Store at 20 o C For research use only. Not for use in diagnostic procedures

More information

CMV DNA Quantification Using an Automated Platform for Nucleic Acid Extraction and Real- time PCR Assay Set-up

CMV DNA Quantification Using an Automated Platform for Nucleic Acid Extraction and Real- time PCR Assay Set-up JCM Accepts, published online ahead of print on 11 May 2011 J. Clin. Microbiol. doi:10.1128/jcm.00721-11 Copyright 2011, American Society for Microbiology and/or the Listed Authors/Institutions. All Rights

More information

Sputum DNA Collection, Preservation and Isolation Kit 50 Individual Devices

Sputum DNA Collection, Preservation and Isolation Kit 50 Individual Devices 3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: techsupport@norgenbiotek.com Sputum DNA Collection, Preservation and Isolation Kit 50 Individual

More information

Mitochondrial DNA Isolation Kit

Mitochondrial DNA Isolation Kit Mitochondrial DNA Isolation Kit Catalog Number KA0895 50 assays Version: 01 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Background... 3 General Information... 4 Materials

More information

1. Intended Use New Influenza A virus real time RT-PCR Panel is used for the detection of universal influenza A virus, universal swine Influenza A vir

1. Intended Use New Influenza A virus real time RT-PCR Panel is used for the detection of universal influenza A virus, universal swine Influenza A vir New Influenza A Virus Real Time RT-PCR Kit User Manual LT028310RRFY - 1 - 1. Intended Use New Influenza A virus real time RT-PCR Panel is used for the detection of universal influenza A virus, universal

More information

Urine - Based CMV PCR Detection Kit Product # 36300

Urine - Based CMV PCR Detection Kit Product # 36300 3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: techsupport@norgenbiotek.com Urine - Based CMV PCR Detection Kit Product # 36300 Product Insert

More information

WHO Prequalification of Diagnostics Programme PUBLIC REPORT. Product: VERSANT HIV-1 RNA 1.0 Assay (kpcr) Number: PQDx

WHO Prequalification of Diagnostics Programme PUBLIC REPORT. Product: VERSANT HIV-1 RNA 1.0 Assay (kpcr) Number: PQDx WHO Prequalification of Diagnostics Programme PUBLIC REPORT Product: VERSANT HIV-1 RNA 1.0 Assay (kpcr) Number: PQDx 0115-041-00 Abstract The VERSANT HIV-1 RNA 1.0 Assay (kpcr) with product codes 10375763,

More information

Product Manual. Omni-Array Sense Strand mrna Amplification Kit, 2 ng to 100 ng Version Catalog No.: Reactions

Product Manual. Omni-Array Sense Strand mrna Amplification Kit, 2 ng to 100 ng Version Catalog No.: Reactions Genetic Tools and Reagents Universal mrna amplification, sense strand amplification, antisense amplification, cdna synthesis, micro arrays, gene expression, human, mouse, rat, guinea pig, cloning Omni-Array

More information

Internal Validation Guide of Y-STR Systems for Forensic Laboratories Printed in USA. 11/12 Part# GE713

Internal Validation Guide of Y-STR Systems for Forensic Laboratories Printed in USA. 11/12 Part# GE713 REFERENCE MANUAL Internal Validation Guide of Y-STR Systems for Forensic Laboratories 11/12 Internal Validation Guide of Y-STR Systems for Forensic Laboratories PLEASE DISCARD PREVIOUS VERSIONS. All technical

More information

altona RealStar Instructions for Use RealStar CMV PCR Kit /2017 EN DIAGNOSTICS

altona RealStar Instructions for Use RealStar CMV PCR Kit /2017 EN DIAGNOSTICS altona DIAGNOSTICS Instructions for Use RealStar CMV PCR Kit 1.2 08/2017 EN RealStar RealStar CMV PCR Kit 1.2 For research use only! (RUO) 021202 INS-021200-EN-S01 48 08 2017 altona Diagnostics GmbH Mörkenstr.

More information

Instructions for Use. RealStar Influenza S&T RT-PCR Kit /2017 EN

Instructions for Use. RealStar Influenza S&T RT-PCR Kit /2017 EN Instructions for Use RealStar Influenza S&T RT-PCR Kit 3.0 01/2017 EN RealStar Influenza S&T RT-PCR Kit 3.0 For research use only! (RUO) 163003 INS-163000-EN-S02 96 01 2017 altona Diagnostics GmbH Mörkenstr.

More information

Circulating Chlamydia pneumoniae DNA as a Predictor of Coronary Artery Disease

Circulating Chlamydia pneumoniae DNA as a Predictor of Coronary Artery Disease Journal of the American College of Cardiology Vol. 34, No. 5, 1999 1999 by the American College of Cardiology ISSN 0735-1097/99/$20.00 Published by Elsevier Science Inc. PII S0735-1097(99)00391-5 Circulating

More information

For purification of viral DNA and RNA from a wide range of sample materials

For purification of viral DNA and RNA from a wide range of sample materials QIAamp virus kits For purification of viral DNA and RNA from a wide range of sample materials Automatable on QIAGEN s proven QIAamp Kits set the standard for purification of viral DNA and RNA. QIAamp virus

More information

RealLine HIV qualitative Str-Format

RealLine HIV qualitative Str-Format Instructions for Use REAL TIME PCR DETECTION KIT FOR HUMAN IMMUNODEFICIENCY VIRUS RNA Research Use Only (RUO) RealLine HIV Qualitative (Str-format) VBD0196 96 Tests valid from July 2016 Rev01072016_EN

More information

Instructions for Use. RealStar Influenza Screen & Type RT-PCR Kit /2017 EN

Instructions for Use. RealStar Influenza Screen & Type RT-PCR Kit /2017 EN Instructions for Use RealStar Influenza Screen & Type RT-PCR Kit 4.0 05/2017 EN RealStar Influenza Screen & Type RT-PCR Kit 4.0 For research use only! (RUO) 164003 INS-164000-EN-S01 96 05 2017 altona

More information

Identification of Microbes Lecture: 12

Identification of Microbes Lecture: 12 Diagnostic Microbiology Identification of Microbes Lecture: 12 Electron Microscopy 106 virus particles per ml required for visualization, 50,000-60,000 magnification normally used. Viruses may be detected

More information

Product Use HPSC-CC are for research use only. It is not approved for human or animal use, or for application in in vitro diagnostic procedures.

Product Use HPSC-CC are for research use only. It is not approved for human or animal use, or for application in in vitro diagnostic procedures. HPSC-derived Cardiomyocyte Cells (HPSC-CC) Catalog #6240 Cell Specification Human primary cardiomyocytes and cardiac tissue are superior modeling systems for heart disease studies, drug discovery and toxicity

More information

Murex Chlamydia Verification Kit

Murex Chlamydia Verification Kit 1F83-01 E C06DK05GB Murex Chlamydia Verification Kit DK05 For the confirmatory testing of clinical samples reactive in Murex Chlamydia (1F82-01) Note Changes Highlighted 2005 Abbott / Printed in the UK

More information

Urinary 8-Isoprostane ELISA kit

Urinary 8-Isoprostane ELISA kit Urinary 8-Isoprostane ELISA kit Catalog Number: 8isoU Store at -20 C. FOR RESEARCH USE ONLY V.020420 Introduction This competitive ELISA kit is for determination of free and glucronidated 8-isoprostane

More information

attomol HLA-B*27-Realtime LT 2 Assay for the detection of the human HLA-B*27-locus using LightCycler (Do not use for tissue typing!

attomol HLA-B*27-Realtime LT 2 Assay for the detection of the human HLA-B*27-locus using LightCycler (Do not use for tissue typing! attomol HLA-B*27-Realtime LT 2 Assay for the detection of the human HLA-B*27-locus using LightCycler (Do not use for tissue typing!) For in vitro diagnostic use only! 50 determinations Order number: 95

More information

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for use with the PrimePCR Reverse Transcription Control Assay

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for use with the PrimePCR Reverse Transcription Control Assay Catalog # Description 172-5080 SingleShot Cell Lysis Kit, 100 x 50 µl reactions 172-5081 SingleShot Cell Lysis Kit, 500 x 50 µl reactions For research purposes only. Introduction The SingleShot Cell Lysis

More information

EXO-DNAc Circulating and EV-associated DNA extraction kit

EXO-DNAc Circulating and EV-associated DNA extraction kit Datasheet EXO-DNAc Circulating and EV-associated DNA extraction kit This product is for research use only. It is highly recommended to read this users guide in its entirety prior to using this product.

More information

Chlamydia pneumoniae in arteries: the facts, their interpretation, and future studies

Chlamydia pneumoniae in arteries: the facts, their interpretation, and future studies J Clin Pathol 1998;51:793 797 793 Leader Imperial College School of Medicine at St Mary s, London W2, UK D Taylor-Robinson B J Thomas Correspondence to: Professor D Taylor-Robinson, Department of Genitourinary

More information

Molecular diagnosis of infectious disease - Method validation and environmental setting 傳染病的分子診斷 - 方法確認與環境背景. WC Yam 任永昌

Molecular diagnosis of infectious disease - Method validation and environmental setting 傳染病的分子診斷 - 方法確認與環境背景. WC Yam 任永昌 Molecular diagnosis of infectious disease - Method validation and environmental setting 傳染病的分子診斷 - 方法確認與環境背景 WC Yam 任永昌 Dept of Microbiology Queen Mary Hospital The University of Hong Kong Clinical and

More information

EXO-DNA Circulating and EV-associated DNA extraction kit

EXO-DNA Circulating and EV-associated DNA extraction kit Datasheet EXO-DNA Circulating and EV-associated DNA extraction kit This product is for research use only. It is highly recommended to read this users guide in its entirety prior to using this product.

More information

Outbreak of Respiratory Tract Infections on an Islet in Korea: Possible Chlamydia pneumoniae Infection

Outbreak of Respiratory Tract Infections on an Islet in Korea: Possible Chlamydia pneumoniae Infection Jpn. J. Infect. Dis., 59, 294-298, 2006 Original Article Outbreak of Respiratory Tract Infections on an Islet in Korea: Possible Chlamydia pneumoniae Infection Kwang-Jun Lee, Su-Jin Kwon, Bo-Ram Choi,

More information

X/01/$ DOI: /CDLI Received 6 November 2000/Returned for modification 6 February 2001/Accepted 27 February 2001

X/01/$ DOI: /CDLI Received 6 November 2000/Returned for modification 6 February 2001/Accepted 27 February 2001 CLINICAL AND DIAGNOSTIC LABORATORY IMMUNOLOGY, May 2001, p. 588 592 Vol. 8, No. 3 1071-412X/01/$04.00 0 DOI: 10.1128/CDLI.8.3.588 592.2001 Comparison of Two Commercial Microimmunofluorescence Kits and

More information

RNA/DNA Stabilization Reagent for Blood/Bone Marrow

RNA/DNA Stabilization Reagent for Blood/Bone Marrow For general laboratory use. Not for use in diagnostic procedures. FOR IN VITRO USE ONLY. RNA/DNA Stabilization Reagent for Blood/Bone Marrow For simultaneous cell lysis and stabilization of nucleic acids

More information

For Research Use Only Ver

For Research Use Only Ver INSTRUCTION MANUAL Quick-cfDNA Serum & Plasma Kit Catalog No. D4076 Highlights High-quality DNA, including cell-free, is easily and robustly purified from up to 10 ml of serum/plasma, up to 1 ml amniotic

More information

XTRAKT FFPE Kit / Manual

XTRAKT FFPE Kit / Manual XTRAKT FFPE Kit / Manual For manual extraction of RNA, mirna and/or DNA from Formalin Fixed Paraffin Embedded (FFPE) tissue samples Catalog No. # XTK2.0-96 For research use only. Not intended for diagnostic

More information

VQA Control SOP Version 4.0 Roche Amplicor HIV-1 DNA Test, v August 2007

VQA Control SOP Version 4.0 Roche Amplicor HIV-1 DNA Test, v August 2007 1. PRINCIPLE 1.1. The Virology Quality Assurance (VQA) Laboratory provides external cell pellet controls for use in the validation of assays that detect HIV proviral DNA. 1.2. HIV seronegative peripheral

More information

RealLine HCV Qualitative Str-Format

RealLine HCV Qualitative Str-Format Instructions for use REAL TIME PCR DETECTION KIT FOR THE HEPATITIS C VIRUS RNA (HCV) Research Use Only (RUO) (Str-format) VBD0795 96 Tests valid from: October 2018 Rev05_1018_EN Page 1 of 8 Explanation

More information

HDV Real-TM. Handbook

HDV Real-TM. Handbook HDV Real-TM Handbook for use with RotorGene 3000/6000 (Corbett Research), SmartCycler (Cepheid), iq icycler and iq5 (Biorad), Applied Biosystems 7300/7500 Real Time PCR Systems (Applera), MX3000P and MX3005P

More information

Human Immunodeficiency Virus-1 (HIV-1) Genemer. Primer Pair for amplification of HIV-1 Specific DNA Fragment

Human Immunodeficiency Virus-1 (HIV-1) Genemer. Primer Pair for amplification of HIV-1 Specific DNA Fragment Product Manual Human Immunodeficiency Virus-1 (HIV-1) Genemer Primer Pair for amplification of HIV-1 Specific DNA Fragment Catalog No.: 60-2002-10 Store at 20 o C For research use only. Not for use in

More information

A Comparison of Ligase Chain Reaction to

A Comparison of Ligase Chain Reaction to Infectious Diseases in Obstetrics and Gynecology 6:57-60 (I 998) (C) 1998 Wiley-Liss, Inc. A Comparison of Ligase Chain Reaction to Polymerase Chain Reaction in the Detection of C.hlamydia trachomatis

More information

IV2-113E Use by. Invitron Glargine ELISA Kit REF LOT IVD. Definitions. English. For in-vitro diagnostic use. Instructions for use.

IV2-113E Use by. Invitron Glargine ELISA Kit REF LOT IVD. Definitions. English. For in-vitro diagnostic use. Instructions for use. Definitions Instructions for use REF Catalogue number IV2-113E Use by English Invitron Glargine ELISA Kit For in-vitro diagnostic use Σ 96 LOT IVD Lot/Batch Code Storage temperature limitations In vitro

More information

Human Influenza A (Swine Flu) Rapid test

Human Influenza A (Swine Flu) Rapid test Human Influenza A (Swine Flu) Rapid test Cat.No: DTSXY-Z9 Lot. No. (See product label) Size 20T Intended use The Influenza A (Swine Flu) test is a rapid chromatographic immunoassay for the qualitative

More information

CRISPRaTest Functional dcas9-activator Assay Kit v1 Last update: 2018/07/04 Cellecta, Inc.

CRISPRaTest Functional dcas9-activator Assay Kit v1 Last update: 2018/07/04 Cellecta, Inc. CRISPRaTest Functional dcas9-activator Assay Kit v1 Last update: 2018/07/04 Cellecta, Inc. Copyright (c) 2018 Cellecta, Inc. All Rights Reserved. Table of Contents 1. CRISPRaTest Functional dcas9-activator

More information

AquaPreserve DNA/RNA/Protein Order # Preservation and Extraction Kit 8001MT, 8060MT

AquaPreserve DNA/RNA/Protein Order # Preservation and Extraction Kit 8001MT, 8060MT AquaPreserve DNA/RNA/Protein Order # Preservation and Extraction Kit 8001MT, 8060MT MoBiTec GmbH 2014 Page 2 Contents 1. Description... 3 2. Kit Contents... 3 3. Terms & Conditions... 3 4. AquaPreserve

More information

VQA HIV DNA Control SOP Version 5.0 HIV DNA Testing 13 March 2012

VQA HIV DNA Control SOP Version 5.0 HIV DNA Testing 13 March 2012 1. PRINCIPLE 1.1. The Virology Quality Assurance (VQA) Laboratory provides external cell pellet controls for use in the validation of assays that detect HIV proviral DNA. 1.2. HIV seronegative peripheral

More information

INTRODUCTION PRODUCT DESCRIPTION

INTRODUCTION PRODUCT DESCRIPTION INTRODUCTION Mycoplasma are known as important contaminants of biological products derived from cell lines in the biopharmaceutical industry affecting every parameter of a cell culture system. Contaminated

More information

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2

02006B 1 vial 02006B 1 vial Store at -20 C. Lyophilized recombinant IL-2 For detection and measurement of human interleukin 2 Catalog #02006 Catalog #02007 2 Plates 10 Plates Product Description The Human Interleukin 2 (IL-2) ELISA Kit is designed for the quantitative detection

More information

Rubella Latex Agglutination Test

Rubella Latex Agglutination Test Rubella Latex Agglutination Test Cat. No.:DLAT1088 Pkg.Size:30T Intended use The Rubella Latex Agglutination Test is a rapid latex particle agglutination test for the qualitative and semi-quantitative

More information

HIV-1 Genemer Detection Kit Ready to Use Amplification Kit for HIV-1 Specific DNA Fragment Analysis

HIV-1 Genemer Detection Kit Ready to Use Amplification Kit for HIV-1 Specific DNA Fragment Analysis Product Manual HIV-1 Genemer Detection Kit Ready to Use Amplification Kit for HIV-1 Specific DNA Fragment Analysis For research use only. Not for use in diagnostic procedures for clinical purposes Catalog

More information

Validation Report: VERSA Mini PCR Workstation Reverse Transcription of Avian Flu RNA and Amplification of cdna & Detection of H5N1

Validation Report: VERSA Mini PCR Workstation Reverse Transcription of Avian Flu RNA and Amplification of cdna & Detection of H5N1 I. Objectives Validation Report: VERSA Mini PCR Workstation Reverse Transcription of Avian Flu RNA and Amplification of cdna & Detection of H5N1 1. To ensure stability of RNA (highly thermolabile and degradatively

More information

A complete next-generation sequencing workfl ow for circulating cell-free DNA isolation and analysis

A complete next-generation sequencing workfl ow for circulating cell-free DNA isolation and analysis APPLICATION NOTE Cell-Free DNA Isolation Kit A complete next-generation sequencing workfl ow for circulating cell-free DNA isolation and analysis Abstract Circulating cell-free DNA (cfdna) has been shown

More information

Lumino Firefly Luciferase Assay

Lumino Firefly Luciferase Assay G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name Lumino Firefly Luciferase Assay (Cat. # 786 1267, 786 1268) think proteins! think G-Biosciences

More information

ACTG Laboratory Technologist Committee Revised Version 2.0 ACTG Lab Man Coulter HIV-1 p24 ELISA May 21, 2004

ACTG Laboratory Technologist Committee Revised Version 2.0 ACTG Lab Man Coulter HIV-1 p24 ELISA May 21, 2004 Coulter HIV p24 1. PRINCIPLE The Human Immunodeficiency Virus Type 1 (HIV-1) is recognized as the etiologic agent of acquired immunodeficiency syndrome (AIDS). The virus is transmitted by sexual contact,

More information

Midi Plant Genomic DNA Purification Kit

Midi Plant Genomic DNA Purification Kit Midi Plant Genomic DNA Purification Kit Cat #:DP022MD/ DP022MD-50 Size:10/50 reactions Store at RT For research use only 1 Description: The Midi Plant Genomic DNA Purification Kit provides a rapid, simple

More information

RealLine HBV / HCV / HIV Str-Format

RealLine HBV / HCV / HIV Str-Format Instructions for use ASSAY KIT FOR THE QUALITATIVE AND DIFFERENTIAL DETECTION OF HEPATITIS B VIRUS DNA, HEPATITIS C VIRUS RNA, AND HUMAN IMMUNODEFICIENCY VIRUS TYPES 1 AND 2 RNA USING THE PCR/RT-PCR METHOD

More information

Chlamydia pneumoniae PCR reagents Detection with real time PCR reagents

Chlamydia pneumoniae PCR reagents Detection with real time PCR reagents Chlamydia pneumoniae PCR reagents Detection with real time PCR reagents Overview:... 1 Products... 2 C. pneumoniae FAM-BHQ1 Primer-probe PP3400 0.055ml... 2 AttoMaster 2X Mix for qpcr AM10 1.25 ml... 2

More information

Chlamydia pneumoniae in atheroma: consideration of criteria for causality

Chlamydia pneumoniae in atheroma: consideration of criteria for causality 812 School of Pathology, University of the Witwatersrand, South Africa A Shor National Centre for Occupational Health, Johannesburg, South Africa J I Phillips MRC Sexually Transmitted Diseases Research

More information

Total Histone H3 Acetylation Detection Fast Kit (Colorimetric)

Total Histone H3 Acetylation Detection Fast Kit (Colorimetric) Total Histone H3 Acetylation Detection Fast Kit (Colorimetric) Catalog Number KA1538 48 assays Version: 02 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use...

More information

Pinpoint Slide RNA Isolation System II Catalog No. R1007

Pinpoint Slide RNA Isolation System II Catalog No. R1007 INSTRUCTION MANUAL Pinpoint Slide RNA Isolation System II Catalog No. R1007 Highlights Allows for the isolation of total RNA from paraffin-embedded tissue sections on glass slides Simple procedure combines

More information

AmpliX HBV Quantitative

AmpliX HBV Quantitative Instructions for use REAL TIME PCR DETECTION AND QUANTITATION KIT OF HEPATITIS B VIRUS DNA Research Use Only (RUO) (Lyo-format) VBD0595 96 rcs valid from May 2013 Explanation of symbols used in labeling

More information

ACTG Laboratory Technologist Committee Revised Version 2.0 ACTG Lab Man HIV Qualitative PBMC Micrococulture 1 June 2004

ACTG Laboratory Technologist Committee Revised Version 2.0 ACTG Lab Man HIV Qualitative PBMC Micrococulture 1 June 2004 HIV QUALITATIVE PBMC MICROCOCULTURE ASSAY 1. PRINCIPLE: 1.1 A co-culture of patient peripheral blood mononuclear cells (PBMC) and uninfected PHA-stimulated PBMCs is maintained under ideal conditions to

More information

EpiQuik Circulating Acetyl Histone H3K18 ELISA Kit (Colorimetric)

EpiQuik Circulating Acetyl Histone H3K18 ELISA Kit (Colorimetric) EpiQuik Circulating Acetyl Histone H3K18 ELISA Kit (Colorimetric) Base Catalog # PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE Uses: The EpiQuik Circulating Acetyl Histone H3K18 ELISA Kit (Colorimetric)

More information

E.Z.N.A. SQ Blood DNA Kit II. Table of Contents

E.Z.N.A. SQ Blood DNA Kit II. Table of Contents E.Z.N.A. SQ Blood DNA Kit II Table of Contents Introduction and Overview...2 Kit Contents/Storage and Stability...3 Blood Storage and DNA Yield...4 Preparing Reagents...5 100-500 μl Whole Blood Protocol...6

More information

Chromatin IP (Isw2) Fix soln: 11% formaldehyde, 0.1 M NaCl, 1 mm EDTA, 50 mm Hepes-KOH ph 7.6. Freshly prepared. Do not store in glass bottles.

Chromatin IP (Isw2) Fix soln: 11% formaldehyde, 0.1 M NaCl, 1 mm EDTA, 50 mm Hepes-KOH ph 7.6. Freshly prepared. Do not store in glass bottles. Chromatin IP (Isw2) 7/01 Toshi last update: 06/15 Reagents Fix soln: 11% formaldehyde, 0.1 M NaCl, 1 mm EDTA, 50 mm Hepes-KOH ph 7.6. Freshly prepared. Do not store in glass bottles. 2.5 M glycine. TBS:

More information

The Prevalence of Chlamydia pneumoniae

The Prevalence of Chlamydia pneumoniae 152 JACC Vol. 33, No. 1 The Prevalence of Chlamydia pneumoniae in Atherosclerotic and Nonatherosclerotic Blood Vessels of Patients Attending for Redo and First Time Coronary Artery Bypass Graft Surgery

More information

Europium Labeling Kit

Europium Labeling Kit Europium Labeling Kit Catalog Number KA2096 100ug *1 Version: 03 Intended for research use only www.abnova.com Table of Contents Introduction... 3 Intended Use... 3 Background... 3 Principle of the Assay...

More information

Introduction to Cladosporium_spp

Introduction to Cladosporium_spp Techne qpcr test Cladosporium_spp 150 tests For general laboratory and research use only 1 Introduction to Cladosporium_spp Cladosporium is a genus of slow growing fungi, colonies are mostly dark green

More information

Identification of Chlamydia pneumoniae by DNA Amplification

Identification of Chlamydia pneumoniae by DNA Amplification JOURNAL OF CLINICAL MICROBIOLOGY, Apr. 1992, p. 796-800 0095-1137/92/040796-05$02.00/0 Copyright 1992, American Society for Microbiology Vol. 30, No. 4 Identification of Chlamydia pneumoniae by DNA Amplification

More information

RealLine HIV quantitative Str-Format

RealLine HIV quantitative Str-Format Instructions for use DETECTION AND QUANTIFICATION OF THE HUMAN IMMUNODEFICIENCY VIRUS RNA BY REAL TIME PCR Research Use Only (RUO) Attention! Please read the information about quantification process carefully!

More information

Immunoblotting Analysis of Abdominal Aortic Aneurysms Using Antibodies Against Chlamydia pneumoniae Recombinant MOMP

Immunoblotting Analysis of Abdominal Aortic Aneurysms Using Antibodies Against Chlamydia pneumoniae Recombinant MOMP Eur J Vasc Endovasc Surg 24, 81±85 (2002) doi:10.1053/ejvs.2002.1658, available online at http://www.idealibrary.com on Immunoblotting Analysis of Abdominal Aortic Aneurysms Using Antibodies Against Chlamydia

More information

Chlamydia Rapid Screen Test (RAP-2858) RUO in the USA. Revised 28 Jul 2006

Chlamydia Rapid Screen Test (RAP-2858) RUO in the USA. Revised 28 Jul 2006 INDICATION For the rapid detection of Chlamydia Trachomatis antigens in swab specimens. For in vitro diagnostic use only, except in the United States where it is intended for Research Use Only. SUMMARY

More information

Tabriz, Iran 5Department of Parasite and Fungal diseases, Razi Institute, Iran

Tabriz, Iran 5Department of Parasite and Fungal diseases, Razi Institute, Iran Journal of Research in Medical and Dental Sciences 2018, Volume 6, Issue 3, Page No: 1-6 Copyright CC BY-NC-ND 4.0 Available Online at: www.jrmds.in eissn No. 2347-2367: pissn No. 2347-2545 The Presence

More information

CEPHIA Consortium for the Evaluation and Performance of HIV Incidence Assays STANDARD OPERATING PROCEDURE

CEPHIA Consortium for the Evaluation and Performance of HIV Incidence Assays STANDARD OPERATING PROCEDURE CEPHIA Consortium for the Evaluation and Performance of HIV Incidence Assays STANDARD OPERATING PROCEDURE TITLE : SOP for (off board dilution) Less Sensitive Modified VITROS Enzyme Immunoassay CEPHIA DOCUMENT

More information

XCF TM COMPLETE Exosome and cfdna Isolation Kit (for Serum & Plasma)

XCF TM COMPLETE Exosome and cfdna Isolation Kit (for Serum & Plasma) XCF TM COMPLETE Exosome and cfdna Isolation Kit (for Serum & Plasma) Cat# XCF100A-1 User Manual Store kit components at +4ºC and +25ºC Version 1 2/2/2017 A limited-use label license covers this product.

More information

Xpert MTB/RIF Training. Indira Soundiram 2012

Xpert MTB/RIF Training. Indira Soundiram 2012 Xpert MTB/RIF Training Indira Soundiram 2012 A Better Way to Platform Design GeneXpert Infinity-48 GeneXpert Module GX-I GX-II GX-IV GX-XVI 2 Defining Molecular Diagnostics Any Test Any Time Any Sample

More information