4 Columns for HTS and LC/MS Analysis
|
|
- Earl Watson
- 5 years ago
- Views:
Transcription
1 YMC GENERAL CATALG Columns for HTS and LC/MS Analysis Semi-micro columns for LC/MS YMC-UltraHT series YMC CombiChrom ,99 93 第 章.indd :51:39 AM
2 Semi-micro columns for LC/MS Wide selection of packing materials and column sizes Most suitable for microanalysis S e m i - m i c r o c o l u m n s o p t i m i z e d f o r L C / M S YMC Co., Ltd. s Semi-micro columns are high performance columns, providing good peak shapes when used with mobile phase suitable for LC/MS. They come in a wide range of column sizes and with a wide selection of packing materials. This enables column selection according to the intended purpose, such as rapid analysis or precise separation. Abundant packing material types Packing material Triart C18 Pro C18 Hydrosphere C18 Pro C18 RS Pro C8 Pro C TMS Ph CN Characteristics Versatile hybrid silica based DS column, great chemical durability, excellent peak shape in every condition High performance DS packing material Can be used with 1 water mobile phase Superior separation for hydrophilic compounds High carbon DS packing material, high durability Separation behavior may differ from DS, since stationary phase hydrophobicity is lower than DS Have available π electrons derived from functional groups and show different separation characteristics from DS. π-π interactions For details about characteristics of these and other packing materials, see pages for each column. Reduced column bleed 1.E+9 8.E+8 TIC Triart C18 No column Bleeding of stationary phases can often contribute to high back ground signals when employing MS and other hyphenated detection techniques. YMC Triart C18 column shows no contribution to the signal observed by the MS positive total ion current (TIC) trace. Such performance allows for low limits of detection (high S/N ratio) for MS and other detection techniques..e+8.e min Column : YMC-Triart C18 (5 µm, 1 Å) 5. mmi.d. Eluent : A) water/formic acid (1/.1) B) acetonitrile/formic acid (1/.1) 5 B (-1 min), 5-1 B (1-5 min), 1 B (5-1 min), 1-5 B (1-1.1 min), 5 B ( min) Flow rate :. ml/min Temperature : Detection :ESI positive, TIC (m/z 5-1) A p p l i c a t i o n mau 1 5 Melamine-spiked pet food (1 mg/kg, final.5 µg/ml) NH N N H N N NH Melamine Sample preparation method Pet food (1 g) 5 aqueous acetonitrile (5 ml) Sonication for 3 min Centrifugation at 1, rpm for 1 min Filtration Dilution times with eluent A Filtration Injection min (R819D) Melamine in pet food, conditions for LC/MS Column : YMC-UltraHT Hydrosphere C18 ( µm, 1 Å) 5. mmi.d. Eluent : A) water/heptafluorobutyric acid (1/.1) B) methanol/heptafluorobutyric acid (1/.1) 5 B (-.17 min), 5-9 B (.17-3 min) Flow rate :. ml/min Temperature : Detection :UV at nm Injection :1 µl Melamine in pet food was analyzed with volatile eluent for LC/MS analysis. Hydrosphere C18 is suitable LC/MS column for hydrophilic compounds that are difficult to retain in reversed phase conditions. 9 第 章.indd :51:1 AM
3 A p p l i c a t i o n Intens. sample_1ul_-c,5_1_753.d: BPC All MS x1 (S9111A) LC/TF-MS analysis of the in vitro metabolites of diltiazem in human liver S9 metabolites unchanged DTZ Diltiazem HCl (DTZ) min Intens. x1 BPC sample_1ul_-c,5_1_753.d: BPC All MS x1 EIC [unchanged DTZ] sample_1ul_-c,5_1_753.d: EIC 15.19±.1 +All MS x1 x1 x1 EIC [-CH] EIC [-CCH] EIC [-(CH)] EIC [-C(CH)] EIC [-C(CH)3] sample_1ul_-c,5_1_753.d: EIC 1.153±.1 +All MS sample_1ul_-c,5_1_753.d: EIC ±.1 +All MS sample_1ul_-c,5_1_753.d: EIC ±.1 +All MS sample_1ul_-c,5_1_753.d: EIC 359.1±.1 +All MS sample_1ul_-c,5_1_753.d: EIC 35.17±.1 +All MS min A p p l i c a t i o n Courtesy of J.Watanabe, Bruker Daltonics K. K. Column : YMC-UltraHT Hydrosphere C18 ( µm, 1 Å) 5. mmi.d. Eluent : A) mm HCNH, B) methanol 5 B (-.5 min), 5-8 B ( min), 8 B (3.5- min) Flow rate :. ml/min Temperature : 37 Detection : ESI, positive mode, m/z 1-1 (Bruker Daltonics micrtf II) YMC-UltraHT Hydrosphere C18 is suitable for ultra fast LC analysis of hydrophilic compounds like drug metabolites. It is possible to analyze in short time due to the combination high resolution µm column and TF-MS analysis. (F118B) Diode Array 7 nm 1.5e3 min TIC 1.e7 m/z 1 1.8e m/z 5 1.8e m/z e LC/MS analysis of tetracycline antibiotics 3 1 H H3C xytetracycline (MW.) HC 3 H3C Tetracycline (MW.) Cl HC 3 Chlortetracycline (MW 78.8) N H3C H3C N N N NH NH NH X peak area 1 R = concentration (µg/ml) min NH Column : YMC-Triart C18 (5 µm, 1 Å) 5. mmi.d. Eluent : acetonitrile/water/formic acid (15/85/.1) Flow rate :. ml/min Temperature : Detection : A) UV at 7 nm B) ESI positive-mode Injection : 1 µl (.-1 µg/ml) Doxycycline (MW.) Triart C18 shows no adsorption for coordinate compound of tetracyclines with good peak shape and quantitative. Therefore, it is applicable for high sensitive analysis. 95 第 章.indd :51:5 AM
4 Analytical columns Semi-micro columns for LC/MS rdering information Semi-micro column for LC/MS(See P,7 for µm of UltraHT Series) Packing material Particle size Pore size (µm) (Å) Column size inner diameter length(mm) Triart C18 S TA1S3-3WT. 5 TA1S3-5WT. 75 TA1S3-L5WT. 1 TA1S3-1WT. 15 TA1S3-15WT S TA1S5-3WT. 5 TA1S5-5WT. 75 TA1S5-L5WT. 1 TA1S5-1WT. 15 TA1S5-15WT Pro C18 S AS1S3-H51WT 1. 5 AS1S3-51WT 1. 1 AS1S3-11WT AS1S3-H5P5WT AS1S3-5P5WT AS1S3-1P5WT. 35 AS1S3-H5WT. 5 AS1S3-5WT. 75 AS1S3-L5WT. 1 AS1S3-1WT. 15 AS1S3-15WT S AS1S5-151WT 1. 5 AS1S5-51WT AS1S5-15P5WT AS1S5-5P5WT. 35 AS1S5-H5WT. 5 AS1S5-5WT. 75 AS1S5-L5WT. 1 AS1S5-1WT. 15 AS1S5-15WT. 5 AS1S5-5WT Hydrosphere C18 S HS1S3-H51WT 1. 5 HS1S3-51WT 1. 1 HS1S3-11WT HS1S3-H5P5WT HS1S3-5P5WT HS1S3-1P5WT. 35 HS1S3-H5WT. 5 HS1S3-5WT. 75 HS1S3-L5WT. 1 HS1S3-1WT. 15 HS1S3-15WT S HS1S5-151WT 1. 5 HS1S5-51WT HS1S5-15P5WT HS1S5-5P5WT. 35 HS1S5-H5WT. 5 HS1S5-5WT. 75 HS1S5-L5WT. 1 HS1S5-1WT. 15 HS1S5-15WT. 5 HS1S5-5WT Packing material Particle size Pore size (µm) (Å) Column size inner diameter length(mm) Pro C18 RS S RS8S3-H51WT 1. 5 RS8S3-51WT 1. 1 RS8S3-11WT RS8S3-H5P5WT RS8S3-5P5WT RS8S3-1P5WT. 35 RS8S3-H5WT. 5 RS8S3-5WT. 75 RS8S3-L5WT. 1 RS8S3-1WT. 15 RS8S3-15WT S RS8S5-151WT 1. 5 RS8S5-51WT RS8S5-15P5WT RS8S5-5P5WT. 35 RS8S5-H5WT. 5 RS8S5-5WT. 75 RS8S5-L5WT. 1 RS8S5-1WT. 15 RS8S5-15WT. 5 RS8S5-5WT Pro C8 S S1S3-H5WT. 5 S1S3-5WT. 75 S1S3-L5WT S S1S5-151WT 1. 5 S1S5-51WT S1S5-15P5WT S1S5-5P5WT. 5 S1S5-5WT. 75 S1S5-L5WT. 1 S1S5-1WT. 15 S1S5-15WT Pro C S BS1S3-H5WT. 5 BS1S3-5WT. 75 BS1S3-L5WT S BS1S5-151WT 1. 5 BS1S5-51WT BS1S5-15P5WT BS1S5-5P5WT. 5 BS1S5-5WT. 75 BS1S5-L5WT. 1 BS1S5-1WT. 15 BS1S5-15WT 9 第 章.indd :51: AM
5 YMC-UltraHT series YMC-UltraHT series are C18 bonded-phases based on highly efficient µm spherical silica particles. YMC-UltraHT series columns are specially designed for high-speed and high throughput analysis in various fields such as pharmaceuticals, foods, and environmental. The YMC-UltraHT series have two See P 7 for details of YMC-UltraHT series. products; Pro C18 is as our standard DS, and Hydrosphere C18 for hydrophilic compounds. Both show the same selectivity and superior peak shapes as 3 µm and 5 µm Pro series, so easy method transfer from conventional HPLC to ultra-fast LC is available without changing elution conditions. Simultaneous analysis for agricultural chemicals by LC/MS YMC-Pack Pro C mmi.d. 3 µm Gradient : 15- B (-1 min), B (1-3.5 min), -5 B (3.5- min), 5-55 B (-8 min), B ( min), 95 B (17.5- min) Flow rate :. ml/min Intensity, cps Intensity, cps 9.5e5 9.e5 8.5e5 8.e5 7.5e5 7.e5.5e5.e5 5.5e5 5.e5.5e5.e5 3.5e5 3.e5.5e5.e5 1.5e5 1.e5 5.e. Gradient Flow rate 1.e 9.e5 8.e5 7.e5.e5 5.e5.e5 3.e5.e5 1.e5. XIC of +MRM (5 pairs) YMC-UltraHT Pro C mmi.d. µm : 15- B (-.5 min), B ( min), -5 B ( min), 5-55 B (3- min), B (-8.75 min), 95 B ( min) :. ml/min XIC of +MRM (5 pairs) , Time, min 9 1, Eluent : A) 5 mm CNH in water B) 5 mm CNH in methanol Temperature :ambient Detection :ESI, Positive, MRM (API5) Sample : Pesticide Mixture Standard Solution PL-7-, manufactured by Wako Pure Chemical Industries, Ltd Time, min 7 analysis time 1/ , , Max..8e5 cps. Max. 3.e5 cps. Courtesy of J.Watanabe, TAKARA BI INC. 1. Thiamethoxam (Q1/Q3 : 9.3/11.3). Clothianidin (Q1/Q3 : 5.3/19.1) 3. Chloridazon (Q1/Q3 :.3/77.). Thiacloprid (Q1/Q3 : 53.3/1.) 5. Thiabendazole (Q1/Q3 :.3/175.). Azamethiphos (Q1/Q3 : 35./183.) 7. Dimethirimol (Q1/Q3 : 1./71.1) 8. Isoxaflutole (Q1/Q3 : 3./51.1) 9. Pyriftalid (Q1/Q3 : 319.3/139.1) 1. (E)-Ferimzone (Q1/Q3 : 55./91.1) 11. (Z)-Ferimzone (Q1/Q3 : 55./91.1) 1. Methoxyfenozide (Q1/Q3 : 39./19.3) 13. Iprovalicarb (Q1/Q3 : 31./119.3) 1. Chromafenozide (Q1/Q3 : 395./175.1) 15. Butafenacil (Q1/Q3 : 9.1/331.1) 1. Simeconazole (Q1/Q3 : 9.3/7.1) 17. Cyazofamid (Q1/Q3 : 35./18.) 18. Naproanilide (Q1/Q3 : 9.3/171.3) 19. Fenoxycarb (Q1/Q3 : 3.3/88.1). Anilofos (Q1/Q3 : 38./199.1) 1. Cyflufenamid (Q1/Q3 : 31.3/95.). Pyrazolynate (Q1/Q3 : 39.1/91.) 3. Indoxacarb (Q1/Q3 : 58.1/3.). Benzofenap (Q1/Q3 : 31./15.1) 5. Furathiocarb (Q1/Q3 : 383.3/195.). Cloquintocet-mexyl (Q1/Q3 : 33.3/38.) Shown in above chromatogram, the compounds of agricultual chemicals were analyzed on Pro C18 column (3 µm, 15. mmi.d.). Every basic compound shows good peak shape. Below chromatogram was obtained with UltraHT Pro C18 ( µm, 75. mmi.d.), it shows same separation pattern with short time analysis. 97 第 章.indd :5:3 AM
6 High throughput column YMC CombiChrom Column with a particle size of 5 µm and a length of 5 mm for high-speed separation The most suitable column design for gradient analysis Excellent durability F o r s c r e e n i n g o r i s o l a t i o n o f c o m b i n a t o r i a l c h e m i s t r y c o m p o u n d s YMC CombiChrom is intended for screening or isolation of combinatorial chemistry compounds. Its excellent durability enables it to be used under severe conditions, including high flow rate, and it may be scaled-up from analytical to preparative. High-speed separation using CombiChrom min 1B 5 1 min Eluent: A) water/acetic acid (99/1) B) methanol/acetic acid (99/1) 1B CombiChrom can greatly shorten gradient elution analysis time due to a high flow rate. As a result, as many as samples per day can be treated, and the amount of mobile phase used can be reduced. 1. p-hydroxybenzoic acid. n-propyl gallate 3. -Hydroxymethyl-,-di-tert-butylphenol. n-ctyl gallate 5. n-dodecyl gallate 5 mm column Cycle time min CombiChrom Cycle time 7.5 min Possible number of gradient analyses per day 8 times Possible number of gradient analyses per day 19 Amount of mobile phase required for one gradient cycle Analytical column, ml Preparative column, 1 ml (5 mmi.d.) about 1/3 Amount of mobile phase required for one gradient cycle Screen,.5 ml Prep, 5 ml (5 mmi.d.) 98 第 章.indd :5:3 AM
7 Scale-up Scale-up to isolation can be achieved easily because the analytical conditions of CombiScreen can be directly applied to CombiPrep. 8 1 min 8 1 min Eluent : A) acetonitrile/water/acetic acid (7/3/1) B) acetonitrile/acetic acid (1/1) -1 B (- min), 1 B (-1 min) 1- B (1-1.1 min), B ( min) Temperature :ambient Detection :UV at 5 nm rdering information YMC CombiChrom Packing material Particle size (µm) CombiScreen. 5 mm CombiPrep 5 mm CombiPrep 3 5 mm Pro C18 S-5 CCASS5-5WT CCASS5-5WT CCASS5-53WT Hydrosphere C18 S-5 CCHSS5-5WT CCHSS5-5WT CCHSS5-53WT Pro C18 RS S-5 CCRSS5-5WT CCRSS5-5WT CCRSS5-53WT DS-A S-5 CCAAS5-5WT CCAAS5-5WT CCAAS5-53WT DS-AM S-5 CCAMS5-5WT CCAMS5-5WT CCAMS5-53WT DS-AQ S-5 CCAQS5-5WT CCAQS5-5WT CCAQS5-53WT DS-AL S-5 CCALS5-5WT CCALS5-5WT CCALS5-53WT Pro C8 S-5 CCSS5-5WT CCSS5-5WT CCSS5-53WT Pro C S-5 CCBSS5-5WT CCBSS5-5WT CCBSS5-53WT Ph S-5 CCPHS5-5WT CCPHS5-5WT CCPHS5-53WT CN S-5 CCCNS5-5WT CCCNS5-5WT CCCNS5-53WT SIL S-5 CCSLS5-5WT CCSLS5-5WT CCSLS5-53WT Polyamine Ⅱ S-5 CCPBS5-5WT CCPBS5-5WT CCPBS5-53WT Diol-NP (1 Å) S-5 CCDNS5-5WT CCDNS5-5WT CCDNS5-53WT 99 第 章.indd :5:3 AM
8 第 章.indd :5:3 AM
3 Normal-Phase Columns. Reversed-Phase C18 Columns (ODS) Reversed-Phase Columns (Other than ODS) Columns for HTS and LC/MS Analysis.
We are pleased to present the 11th YMC General Catalog. Since its formation in 1980, YMC Co., Ltd. has been working in the rapidly changing field of chemistry. Over this time, the rate of discovery of
More informationDetermination of 44 Pesticides in Foodstuffs by LC/MS/MS Application
Determination of Pesticides in Foodstuffs by LC/MS/MS Application Food Safety Authors Masahiko Takino Agilent Technologies, Inc. Hachioji, Tokyo Japan Toshitsugu Tanaka Kobe Institute of Health Department
More informationReversed-Phase Columns (Other than ODS)
7 Reversed-Phase Columns (ther than DS) Types and characteristics of reversed-phase columns -- 9, 9 YMC-Pack Pro C8, C--------------------------- 96 YMC-Pack C 8 --------------------------------------
More informationLC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D
LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D Introduction Components of pharmaceutical products and food products often include high
More informationYMC-Actus. Columns for Semi-preparative HPLC. Selectivity Durability Loadability
YMC-Actus Columns for Semi-preparative HPLC Selectivity Durability Loadability Fast semi-preparative chromatography Semi-preparative chromatography is the link between analytical HPLC and preparative LC.
More informationYMC-Triart C18. Multilayer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology
YMC-Triart C18 Versatile hybrid silica based HPLC column The Selectivity Company Multilayer hybrid material for HPLC ph and temperature stability Innovative micro-reactor technology www.ymc.de 2 YMC-Triart
More informationSepax Technologies, Inc.
Sepax Technologies, Inc. Sepax Technologies, Inc. develops and manufactures products in the area of chemical and biological separations, biosurfaces and proteomics. Sepax product portfolio includes ) liquid
More informationAnalytical and Preparative SFC Columns
Analytical and Preparative SFC Columns Best Performance for Supercritical Fluid Chromatography Sepax SFC-Cyano... Sepax SFC-Amino... Sepax SFC-Pyridine... Sepax SFC-SCX... 5 Sepax SFC-Diol... 6 Sepax SFC-Silica...
More informationYMC HILIC Columns for Polar Analytes
YMC HILIC Columns for Polar Analytes Polar Analytes Advantages In general, reliable applications in HPLC require a minimum retention factor (k ) of 2. In the widely used reversed phase methods polar compounds
More informationApplication Guide. Ultra Fast HPLC
Application Guide Ultra Fast HPLC Food & Beverages YMC UltraHT HPLC Columns for Ultra Fast LC Nowadays the need for Ultra Fast LC and Rapid Resolution is still growing, especially in the pharmaceutical
More informationYMC-Triart C18. Multi-layer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology
YMC-Triart C18 Versatile hybrid silica based HPLC Column The Selectivity Company Multi-layer hybrid material for HPLC ph and temperature stability Innovative micro-reactor technology www.ymc.de 2 YMC-Triart
More information176 YMC Chiral Columns
176 YMC Chiral Columns YMC Chiral Columns 177 Chiral Columns Content YMC Chiral NEA(R)(S)... 178-181 YMC Chiral CD BR... 182-185 Ordering Information... 186 HPLC Columns for Optical Isomer Separation Introduction
More informationUltrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 1290 Infinity LC system
Ultrafast analysis of synthetic antioxidants in vegetable oils using the Agilent 19 Infinity LC system Application Note Food Authors Standard solution Gerd Vanhoenacker, Frank David, Pat Sandra Research
More informationSelectivity Comparison of Agilent Poroshell 120 Phases in the Separation of Butter Antioxidants
Selectivity Comparison of Agilent Poroshell 1 Phases in the Separation of Butter Antioxidants Application Note Food Testing & Agriculture Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd. Abstract
More informationA New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis
A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis X. Liu, C. Pohl, Dionex Corporation, Sunnyvale, CA, USA ABSTRACT Although reversed-phase (RP) silica columns (e.g., C18 and
More informationUltra Columns. also available. ordering note
: 3μm or 5μm particles; 100Å pore size Our broadest selection of stationary phases, including unique phases. High density bondings, for maximum retention. High-purity, Type B silica gives excellent peak
More informationHyper-fast & Super-rugged
Hyper-fast & Super-rugged UHPLC & HPLC columns FALL 2013 PRODUCT CATALOG Hyper-fast & Super-rugged UHPLC & HPLC columns he introduction of HALO columns, developed using innovative Fused-Core particle
More informationSeparation of Vitamin D and Vitamin D Metabolites on FLARE C18 MM (Mixed Mode) HPLC Column
Diamond Analytics Technical Note: T131-1 Separation of Vitamin D and Vitamin D Metabolites on FLARE C1 MM (Mixed Mode) HPLC Column Introduction In this technical note, the versatility of the diamond-based
More informationUltra Columns HPLC COLUMNS
Acetaminophen, Narcotic Analgesics.............519 Aldehydes, Ketones...........................500 Beclomethasone.............................523 Corticosteroids..............................529 Explosives..................................501
More informationSeQuant ZIC -HILIC For all who expect more...
SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore Corp. is a subsidiary of Merck KGaA, Darmstadt, Germany Poor
More informationAnalysis of HMF by HPLC
COST Action 927 Training School Building Skills on the Analysis of Thermal Process Contaminants in Foods 22-26 October 2007, Ankara Analysis of HMF by HPLC Vural Gökmen O O OH Background O COOH O R 2 Carbonyl
More informationThe Raptor HILIC-Si Column
The Raptor HILIC-Si Column With Raptor LC columns, Restek chemists became the first to combine the speed of superficially porous particles (also known as SPP or core-shell particles) with the resolution
More informationUltra High Performance Liquid Chromatograph. Nexera X2 C196-E079
Ultra High Performance Liquid Chromatograph Nexera X2 C196-E79 Maximizing the Potential of UHPLC/HPLC Analyses Intelligence Intelligent data solutions, including a new i -PDeA peak calculation method for
More informationAgilent Technologies Prep LC Columns
Agilent Technologies Prep LC Columns Agilent Technologies Prep LC Columns Agilent Technologies has always taken seriously its responsibility to ensure your success. That s why all our instruments and supplies
More informationEurospher II the logical choice. Physical properties of Eurospher II silica gel: Silica gel: ultra pure, > % Metal content: < 10 ppm
HPLC SMB smometry Euroline Eurospher II Eurospher II the logical choice After more than years on the market, our Eurospher stationary phase has established a reputation for being a first-class packing
More informationSeQuant ZIC -HILIC For all who expect more...
SeQuant ZIC -ILIC For all who expect more... The better choice for PLC and LC/MS of all types of polar and hydrophilic compounds EMD Millipore is a division of Merck KGaA, Darmstadt, Germany Poor retention
More informationYMC-Triart C18. Multilayer hybrid material for HPLC ph and temperature stability. Innovative micro-reactor technology
YMC-Triart C18 Versatile hybrid silica based HPLC column The Selectivity Company Multilayer hybrid material for HPLC ph and temperature stability Innovative micro-reactor technology www.ymc.de 2 YMC-Triart
More informationNew Solvent Grade Targeted for Trace Analysis by UHPLC-MS
New Solvent Grade Targeted for Trace Analysis by UHPLC-MS Subhra Bhattacharya, Deva H. Puranam, and Stephen C. Roemer Thermo Fisher Scientific Fisher Chemical, One Reagent Lane, Fair Lawn, NJ Material
More information11:00 a.m. EST Telephone Number: Chair Person: Tim Spaeder
Stephen W. Coates LC Columns Marketing Specialist Consumables and Accessories Business Unit May 17, 2 High-Throughput Separations for QA/QC, LC/MS, LC/MS/MS, Combinatorial Chemistry, and Rapid Method Development
More informationACE C18-AR Use the Power!
combines the retention and separation characteristics of a C18 phase with the extra selectivity of an integral phenyl functional group. The combination provides extra resolving power for a wide variety
More informationMass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System
Application Note Food Testing and Agriculture Mass-Based Purification of Natural Product Impurities Using an Agilent 126 Infinity II Preparative LC/MSD System Authors Florian Rieck and Jörg Hippler Agilent
More informationFortis Method Development Options
Method Dev Fortis Method Development Options Choice of Stationary phase functionality Based on Ultra pure silica Reversed Phase (RP) and Normal Phase (NP) options Fortis Ho - Polar endcapped C8 - Increased
More informationSUMMARY, CONCLUSION & RECOMMENDATIONS
196 Chapter-5 SUMMARY, CONCLUSION & RECOMMENDATIONS 197 CHAPTER 5 5.1 Summary, Conclusion and Recommendations Summary and Conclusion are drawn based on the work carried out by the author on development
More informationShuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W
Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky
More informationSeparation of Macrocyclic Lactones (Avermectins) on FLARE C18 MM & FLARE C18+ Columns
Separation of Macrocyclic Lactones (Avermectins) on FLARE C8 MM & FLARE C8+ Columns Introduction Diamond Analytics Technical Note: T05- Avermectins are a series of 6-membered macrocyclic lactone derivatives
More informationExtended Application Note
Extended Application Note Comparison of 4 μm vs. 2.o Columns in Analysis of Drospirenone/Ethinyl Estradiol Tablet APP A-339 www.mtc-usa.com 1-732-578-1777 INTRODUCTION The formulation of drospirenone and
More informationThe high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns.
The high efficiency of sub-2 µm UHPLC columns combined with the low pressure and high speed of monolith columns. Fast High peak capacity Low back pressure PROTEIN PEPTIDE UHPLC COLUMNS Put these new, high-performance
More informationTransfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694
Transfer and Speed-up of Methods to Fused-Core Particle Columns EPA Method 1694 Ed Mauney, Hillel K. Brandes, William H. Campbell, Wayne K. Way, Richard A. Henry, David S. Bell, and Carmen T. Santasania
More informationImpact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids
Impact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids David S. Bell, Carmen T. Santasania, Jennifer Claus, Wayne K. Way, and Craig R. Aurand Supelco, Div. of
More informationA Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS
A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these
More informationDetection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS
Detection of Low Level of Chloramphenicol in Milk and Honey with MIP SPE and LC-MS-MS Olga Shimelis, An Trinh, and Michael Ye Supelco, Div. of Sigma-Aldrich, Bellefonte, PA T407125 Introduction Molecularly
More informationImpurity Profiling of Carbamazepine by HPLC/UV
Application Note: 52049 Impurity Profiling of Carbamazepine by HPLC/UV Terry Zhang, Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela Hypersil GOLD Carbamazepine Drug Analysis
More informationRestek Ultra II HPLC Columns
Restek Ultra II HPLC Columns THE Choice for All U(HPLC) Systems November 2009 1 www.chromtech.net.au, sales@chromtech.net.au, Tel: 03 9762 2034, Fax: 03 9761 1169 Topics for Today Introducing Restek Ultra
More informationOverview on YMC Column Hardware and Phases
Overview on and Phases Content UHPLC Column Hardware PT and CC...page 03 Analytical Column Hardware PTH and WT...page 04 Analytical Column Hardware QT and QC...page 05 Analytical Column Hardware GC...page
More informationUPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes
UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes Catalin E. Doneanu, Weibin Chen, and Jeffrey R. Mazzeo Waters Corporation, Milford, MA, U.S. A P P L I C AT ION B E N E F
More informationAgilent Anion-Exchange Media for Proteins - Loading vs Resolution - Effect of Flow Rate and Example Protein Separations
Agilent Anion-Exchange Media for Proteins - Loading vs Resolution - Effect of Flow Rate and Example Protein Separations Technical Overview Introduction PL-SAX is a hydrophilic strong anion-exchange chromatographic
More informationOverview on YMC Column Hardware and Phases
Overview on and Phases Contents UHPLC Column Hardware PT and CC...page 02 Analytical Column Hardware PTH and WT...page 03 Analytical Column Hardware QT and QC...page 04 Analytical Column Hardware GC...page
More informationDetermination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography
Determination of Tetracyclines in Chicken by Solid-Phase Extraction and High-Performance Liquid Chromatography Application ote Food Safety Authors Chen-Hao Zhai and Yun Zou Agilent Technologies Co. Ltd.
More informationLC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell 120 EC C18 Column
Application Note Clinical Research LC/MS/MS Separation of Cholesterol and Related Sterols in Plasma on an Agilent InfinityLab Poroshell EC C8 Column Authors Rongjie Fu and Zhiming Zhang Agilent Technologies
More informationTransferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC
Transferring a Method for Analysis of DNPH-Derivatized Aldehydes and Ketones from HPLC to UHPLC Application Note Environmental Author Melanie Metzlaff Agilent Technologies, Inc. Waldbronn, Germany Abstract
More informationHigh Throughput simultaneous analysis of 39 amino acids in various foods without derivatization using LC-MS/MS
PO-CON1532E High Throughput simultaneous analysis of 39 amino acids in various foods without derivatization using LC-MS/MS ASMS 2015 ThP 409 Manabu Yukiyama 1, Keiko Matsumoto 1, Jun Watanabe 1, Itaru
More informationRebaudioside a From Multiple Gene Donors Expressed in Yarrowia Lipolytica
Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016 Rebaudioside a From Multiple Gene Donors Expressed in Yarrowia Lipolytica This
More informationLC Columns - Exceed the limit. A premium inert range of LC columns delivering optimal peak shape. ProteCol -P PEEK lined
ProteCol LC Columns - Exceed the limit A premium inert range of LC columns delivering optimal peak shape. ProteCol -G Glass lined ProteCol -P PEEK lined B C A D E F A Column end cap B PEEK frit housing
More informationSPME-LC Fibers for a Variety of Applications
SPME-LC Fibers for a Variety of Applications Robert Shirey 1, Craig Aurand 1, Dajana Vuckovic 2, Katherine Stenerson 1, Yong Chen 1, Leonard Sidisky 1, and Janusz Pawliszyn 2 1 Supelco, Div. of Sigma-Aldrich,
More informationRapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column
APPLICATION NOTE 21673 Rapid and sensitive UHPLC screening of additives in carbonated beverages with a robust organic acid column Authors Aaron Lamb and Brian King, Thermo Fisher Scientific, Runcorn, UK
More informationJournal of Chemical and Pharmaceutical Research
Available on line www.jocpr.com Journal of Chemical and Pharmaceutical Research ISSN No: 0975-7384 CODEN(USA): JCPRC5 J. Chem. Pharm. Res., 2011, 3(2):770-775 Validation of Rapid Liquid Chromatographic
More informationAnalyze Barbiturates in Urine with Agilent 6430 LC/MS/MS and Poroshell 120 EC-C18
Analyze Barbiturates in Urine with Agilent 6 LC/MS/MS and Poroshell EC-C8 Application ote Forensic Toxicology Authors Elijah Steinbauer and Pat Friel Toxicology Laboratory at the Veterans Administration
More informationHICHROM. Chromatography Columns and Supplies NEW PRODUCTS. Catalogue 9. Hichrom Limited
HICHROM Chromatography Columns and Supplies NEW PRODUCTS Catalogue 9 1 The Markham Centre, Station Road Theale, Reading, Berks, RG7 4PE, UK Tel: +44 (0)118 930 3660 Fax: +44 (0)118 932 3484 Email: sales@hichrom.co.uk
More informationPhenyl-Hexyl. UHPLC Columns. lternate, complementary selectivity to C18 and C8 bonded phases
Phenyl-Hexyl UHPLC Columns lternate, complementary selectivity to A C8 and C8 bonded phases articularly recommended for P compounds containing aromatic groups xcellent bonded phase stability for E durable,
More informationHigh-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System
High-Resolution Analysis of Intact Triglycerides by Reversed Phase HPLC Using the Agilent 1290 Infinity LC UHPLC System Application Note Food, Hydrocarbon Processing Authors Michael Woodman Agilent Technologies,
More informationApplication Note. Abstract. Authors. Pharmaceutical
Analysis of xycodone and Its Metabolites-oroxycodone, xymorphone, and oroxymorphone in Plasma by LC/MS with an Agilent ZRBAX StableBond SB-C18 LC Column Application ote Pharmaceutical Authors Linda L.
More informationAnalytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 120 PFP
Analytical Method Development for USP Related Compounds in Paclitaxel Using an Agilent Poroshell 1 PFP Application Note Clinical Research Author Rongjie Fu Agilent Technologies (Shanghai) Co. Ltd Abstract
More informationMeteoric Core. Core-Shell Columns for UHPLC & HPLC. Easy Method Optimization! Excellent Chromatography with Fast Separation!
Meteoric Core Easy Method Optimization! Excellent Chromatography with Fast Separation! Core Porous shell layer Meteoric Core Particle Image Structure Schöttmannshof 19 46539 Dinslaken Phone +49 (0)2064
More informationUsing Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes
Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes Eric S. Grumbach,, Diane M. Diehl and Jeffrey R. Mazzeo 2003 Waters Corp. Outline Introduction HILIC Definition
More informationUnequalled durability against water elution. % tr
Unequalled durability against water elution 2 Revolutionary aqueous durability for aminopropyl phase 1 3 4 1. fructose (2.5mg/mL) 3. sucrose (2.5mg/mL) 500 hr 2. glucose 400 hr Aqueous to non-aqueous Normal
More informationMatrix-induced Signal Enhancement of Propamocarb in LC-MS/MS
Observations concerning a compound a matrix a method other Matrix-induced Signal Enhancement of Propamocarb in LC-MS/MS Reported by: EURL-SRM Version 1 (last update: 24.10.2012) Brief description of problem/observation/solution:
More informationIon Exchange and Reversed Phase interactions in selective Bio-SPME extractions of designer drugs
Ion Exchange and Reversed Phase interactions in selective Bio-SPME extractions of designer drugs Frank Michel, Craig R. Aurand, Robert E. Shirey, Yong Chen, Leonard M. Sidisky sigma-aldrich.com/analytical
More informationInertSustain Amide 技術資料
InertSustain Amide 技術資料 InertSustain Amide Physical Properties Silica Particle Size Surface Area Pore Size Pore Volume Bonded Phase End-capping Carbon Loading ph Range USP Code :ES (Evolved Surface) Silica
More informationHigh-Throughput Separations for QA/QC, LC/MS, LC/MS/MS, Combinatorial Chemistry and Rapid Method Development
Robert Ricker Bio-Applications Scientist CABU April 5, 2 Rapid Resolution HPLC High-Throughput Separations for QA/QC, LC/MS, LC/MS/MS, Combinatorial Chemistry and Rapid Method Development Slide 4 Ultra-Fast
More informationIon Exchange Chromatography COSMOGEL IEX Series Columns
Ion Echange Chromatography COSMOGEL IEX Series Columns Available in 3 different ion-echange modes Anion-echange type, Cation-echange type, Amphoteric ion-echange type Available for 3 different application
More informationEffective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate
Effective use of Pharmacopeia guidelines to reduce cost of chromatographic analysis for Fluticasone propionate Application Note Pharmaceutical QA/QC Author Siji Joseph Agilent Technologies, Inc. Bangalore,
More informationUNISON UK - Amino For Aqueous Elutions and Exceptional Separation Balance
UNISON UK - Amino For Aqueous Elutions and Exceptional Separation Balance Revolutionary aqueous durability Aqueous to non-aqueous High speed normal phase separation 3μm particle size Superior resolution
More informationInertSustainBio C18. Rapid Separations of Proteins and Peptides
InertSustainBio C18 Rapid Separations of Proteins and Peptides High Recoveries of Proteins and Peptides The 200A pore size silica creates the opportunity to separate compounds having a molecular weight
More informationGlycanPac AXR-1 Columns
CHRMATGRAPHY GlycanPac AXR- Columns For High Resolution Glycan Analysis Product Specifications The Thermo Scientific GlycanPac AXR- columns are highperformance, silica-based HPLC columns for simultaneous
More informationConverting a CHP Method for Insulin to Agilent Poroshell 120 Columns
Converting a CHP Method for Insulin to Agilent Poroshell Columns Application Note Biopharm Author Rongjie Fu Agilent Technologies (Shanghai) Co., Ltd. 4 Ying Lun Road Shanghai 3 China Abstract A regulatory
More informationUCT SELECTRA C18 HPLC COLUMN INNOVATION THROUGH CHEMISTRY
UCT SELECTRA C18 HPLC COLUMN INNOVATION THROUGH CHEMISTRY SELECTRA C18 HPLC COLUMNS Benefits Good choice for easily converting current C18 methods Suitable for most traditional reverse phase analyses High
More informationProfiling Analysis of Polysulfide Silane Coupling Agent
C146-E154 Profiling Analysis of Polysulfide lane Coupling Agent Technical Report vol.42 1. Introduction Recently, in line with the oil-conservation movement, silica, as a non-petroleum resource, is increasingly
More informationProbing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION
Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection Michael Jones Waters Corporation, Wilmslow, UK APPLICATION BENEFITS The ACQUITY Arc System is
More informationTerence Hetzel, Thorsten Teutenberg, Torsten C. Schmidt Institut für Energie- und Umwelttechnik e. V.
Terence Hetzel, Thorsten Teutenberg, Torsten C. Schmidt Institut für Energie- und Umwelttechnik e. V. Method development of cytotoxic drugs selectivity IAC Seminar, 06.03.2015 Content Introduction Definition
More informationQuantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System
Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System Marta Kozak Clinical Research Applications Group Thermo Fisher Scientific San Jose CA Clinical Research use only, Not for
More informationInertSustain Phenylhexyl. A New Second Choice Column to Change Chromatographic Behavior
InertSustain Phenylhexyl A ew Second Choice Column to Change Chromatographic Behavior Providing Alternative Selectivity to C8 Phases InertSustain Phenylhexyl columns are bonded with phenylhexyl groups,
More informationThe LC Column Playbook
The LC Column Playbook Mark Powell Applications Engineer Technical Support 1 Overview How do we achieve our goal: Resolution? Efficiency Particle size Column length Selectivity Bonded phase Mobile phase
More informationChoosing Preparative Columns
Choosing Preparative Relationship between Column I.D., Sample Loading Volume and Flow Rate In preparative operations, column internal diameter sizes from 6.0 to 100 mm are widely used. When the analytical
More informationCannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 1290 Infinity II/6230B LC/TOF system
Cannabinoid Profiling and Quantitation in Hemp Extracts using the Agilent 9 Infinity II/63B LC/TOF system Application Brief Authors Mike Adams, Karen Kaikaris, and A. Roth CWC Labs Joan Stevens, Sue D
More informationRaptor HILIC-Si: Simplify the Switch to HILIC
Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed
More informationApplication Note. Separation of clindamycin phosphate and process impurities. Summary. Introduction. Category Pharmaceutical analysis Matrix
Application Note Separation of clindamycin phosphate and process impurities Category Pharmaceutical analysis Matrix Drugs Method UHPLC Keywords Antibiotics, process impurities, quality control Analytes
More informationCOSMOSIL HPLC Columns
COSMOSIL HPLC Columns Sample Organic Compounds (low M.W.) Reversed 3C 18 -EB L1 Octadecyl Excellent for basic compounds 3 µm silica packing material C 18 -MS-II L1 Octadecyl Multi-purpose C 18 Monofunctional
More informationNormal Phase Chemistries
170 Normal Phases Normal Phases 171 Normal Phase Chemistries Contents YMC-Pack SIL (Silica)... 172-173 YMC-Pack PVA-Sil... 174-175 YMC-Pack CN (Cyano)... 176-177 YMC-Pack Diol-NP... 178-179 YMC-Pack Polyamine
More informationApplication of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices
Application ote #LCMS-2 esquire series Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices Introduction The simple monitoring
More informationAgilent 6470 Triple Quadrupole LC/MS System and EMR-Lipid. The Combination for Confident Pesticide Quantitation. Christoph Mueller
Agilent 670 Triple Quadrupole LC/MS System and EMR-Lipid The Combination for Confident Pesticide Quantitation Christoph Mueller Agilent Technologies LCMS Application Scientist EMEAI Food Market Program
More informationAnalysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column
Application Note Pharmaceutical and Food Testing Analysis of Amino Acids Derived Online Using an Agilent AdvanceBio AAA Column Author Lu Yufei Agilent Technologies, Inc. Abstract A liquid chromatographic
More information- intermediate polarity between normal phase silica and other alkyl bonded reversed phases - operates in either normal phase or reversed phase mode
Normal Phases 125 YMC-Pack TMS (C1) - intermediate polarity between normal phase silica and other alkyl bonded reversed phases L13 USP - operates in either normal phase or reversed phase mode YMC-Pack
More informationTransfer. Flexible. Universal. 12 YMC-Triart. Scalable particles: EASY UHPLC HPLC. YMC-Triart: ph 1-12 Temperatures up to 70 C
2 YMC-Triart Transfer Scalable particles: EASY UHPLC HPLC Flexible YMC-Triart: ph -2 Temperatures up to 70 C Universal YMC-Triart for acidic, basic and neutral analytes YMC-Triart 3 YMC-Triart Contents
More informationRapid and sensitive UHPLC screening for water soluble vitamins in sports beverages
APPLICATION NOTE 21671 Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages Authors Jon Bardsley, Thermo Fisher Scientific, Runcorn, UK Keywords Vanquish Flex, Acclaim PolarAdvantage
More informationRapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer
Robert Plumb, Michael D. Jones, and Marian Twohig Waters Corporation, Milford, MA, USA INTRODUCTION The detection and characterization of impurities and degradation products of an active pharmaceutical
More informationRaptor HILIC-Si: Simplify the Switch to HILIC
Stationary Phase: Silica Selectivity Accelerated Raptor HILIC-Si: Simplify the Switch to HILIC Retain polar compounds without ion-pairing reagents. 2.7 µm Raptor core-shell particles provide the speed
More informationErgovaline. [Methods listed in the Feed Analysis Standards] 1 Liquid chromatography Note 1, 2 [Feed Analysis Standards, Chapter 5, Section 2
Ergovaline C 29 35 5 5 MW: 533.619 CAS o.: 2873-38-3 [Summary of ergovaline] Ergovaline is a kind of ergot alkaloids produced by endophytes eotyphodium coenophialum and eotyphodium lolli, symbionts of
More informationSPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine
SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA
More informationLiquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E
Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E Ultra-High Sensitivity By incorporating newly improved ion optics and collision cell technology, the LCMS-8040 provides higher multiple reaction
More information