Latest Innovations in LC/MS/MS from Waters for Metabolism and Bioanalytical Applications

Size: px
Start display at page:

Download "Latest Innovations in LC/MS/MS from Waters for Metabolism and Bioanalytical Applications"

Transcription

1 Latest Innovations in LC/MS/MS from Waters for Metabolism and Bioanalytical Applications Ignatius J. Kass Senior Field Marketing Manager Pharmaceutical MS

2 Challenges in Pharmaceutical Sample Analysis Quantitative Bioanalysis Robust reliable methods Sensitivity Analyte confirmation Matrix effects Metabolites In Safety Testing Obtain qualitative data? Metabolic Profiling Confidence Sensitivity Throughput Obtain quantitative data?

3 New Additions to the Xevo Family Class leading UPLC MS and MS/MS performance Technology for simultaneous targeted quantification and high-sensitivity full scan MS and MS/MS monitoring The most sensitive, exact-mass, quantitative and qualitative benchtop MS/MS system Uses UPLC/MS E, a simple, patented method of data acquisition to comprehensively catalog complex samples in a single analysis

4 Analytical Workflow Engineered Simplicity Prepare IntelliStart technology for simplified set-up Analyze Enhanced compatibility with ACQUITY UPLC Performance and usability through Engineered Simplicity TM Automated calibration check and system monitoring Outstanding instrument sensitivity and selectivity Interpret MassLynx application managers, utilizing chemical intelligence, make sense of large, complex data sets Decide Arrive at business / research critical information faster

5 Intellistart IntelliStart Automated MS Resolution & Calibration Checks Performance and usability through Engineered Simplicity TM IntelliStart Automated MRM Method Developer Quanpedia Automated MRM Time Window & Data Rate Scheduling IntelliStart Automated LC/MS System Check Automatically ensure the system is ready to run IntelliStart Automated System Monitoring.

6 Innovations Providing Solutions for Quantitative Bioanalysis Radar Faster method development Qualitative profiling capability Step Wave Increased sensitivity Tools to assist with Regulatory Guidelines Matrix Factor determination MIST Guidelines

7 Method Development: More Depth to Your Data Fluticasone 501> Fluticasone 501> Radar Solvent Blank Radar Solvent Blank Radar Plasma Blank Radar Plasma Blank Phospholipids 184> Time0 Phospholipids 184> Time

8 Calculating a Spiked Simple MethodMatrix Factor XIC Analyte XIC Internal Standard Solvent + Analyte and Internal Standard Extracted Matrix + Analyte and Internal Standard A= 100 A= 90 A= 95 A= 85 MF = A matrix /A solvent MF = 90/100 =.90 MF = A matrix /A solvent MF = 85/95 =.89 IS Normalized MF = MF AN /MF IS IS Normalized MF =.90/.89 = 1.01

9 Alternate Approach for Calculating Matrix Factors LC Column MRM Signal 1) Determine AnalyteProfile AN and IS injected through the column 2) Inject Solvent Blank 3) Inject Extracted Matrix Blank Solvent Blank injected with post column infusion of AN and IS Extracted Blank injected with post column infusion of AN and IS AN and IS infused post-column Analyte = AN Internal Standard = IS

10 Automating Matrix Factor Calculations: Integrated Intellistart Fluidics

11 Matrix Factor Calculation Results Time Time

12 Quantitative Bioanalysis: Pushing the Sensitivity Barriers Potent, low dose compounds Biologics and Therapeutic peptides challenge the sensitivity requirements: Multiple charge states Many fragments Desmopressin

13 Desmopressin 25x S:N Xevo TQ-S Xevo TQ

14 StepWave, Radar and ScanWave Enabled Analysis: More Information Ibuprofen - MRM Glucuronide Metabolite Full Scan MS Hydroxyl - Glucuronide Metabolite - Full Scan MS Ketone Metabolite - Full Scan MS

15 ScanWave Enhanced Product Ion Spectra Ibuprofen MRM ScanWave Collision Cell Enhanced product ion spectra Ketone Metabolite Glucuronide Metabolite Hydroxyl Glucuronide Metabolite

16 An alternate Approach to Full Scan Profiling Metabolites Screen for selected panel of metabolites Commonly reported metabolites User definable Predicts metabolite MRMs based upon Parent Compound MSMS Generates MANY MRMs 1 msec dwell With RADAR, full scan MS may be added to the experiment

17 Develop Theoretical MRMs to Investigate MSMS of Parent Compound Identify Product Ions From Parent Compound Select Metabolites from list of probable transformations MS Source and Analyzer Conditions Automatic Product Ion Selection Spectra of Parent Automatically Obtained from MassLynx Calculate MRMs and Write MS Method File imrm Method List of Potential Metabolites from Text File

18 imrm method

19 Compare Full Scan vs MRM Experiment Full Scan MS MRM Group hr 17_4_005a _4_005a _4_005a 100 XIC Group hr 12: MS2 ES e : MS2 ES e5 XIC : MS2 ES e5 XIC Dealkylation Hydroxylation Demethylation 1.84 MRM > MRM > MRM > _4_005a : MS2 ES e6 XIC Parent 2.11 MRM 442.2> Time 0 Time

20 m/z 428 -Demethylation 1.84 MRM > PIC Scan Acquisition e Full Scan MS XIC m/z

21 Metabolic Stability Plots Demethylation Hydroxylation

22 Latest innovations in Metabolite Profiling Xevo G2 QTof Intellistart Maximizes instrument uptime and ensures optimal performance and consistency From Lab to Lab and user to user QuanTof MS E Quantitative information in addition to full high resolution scan accurate mass profiling Structural analysis for metabolite localization

23 Metabolite Identification WorkFlow For in-vitro/in-vivo samples Resolve metabolites chromatographically UPLC strategy for sensitivity and resolution Detect metabolites UPLC/MS, MS E Exact mass, Data rich information Eliminate background and control peaks Identify metabolites MetaboLynx for data processing Identification of expected and unexpected metabolites Mass defect filtering Confirm metabolite structures MassFragment for metabolite structure assignment and confirmation Quantify metabolites Absolute or relative quantification of metabolites

24 Alternate Scanning LC-MS (LC-MS E ) time resolved accurate mass measurements LE LE m1 sec EE D. EE Gas cell collision energy alternates between MS E low (typically, 5 ev) and is a UNBIASED process elevated energy (typically,5 ev linear ramp from 15 ev - 42 ev) LC-MS E alternate scanning provides quantitative accurate mass measurement for all detectable peptide precursor and product ions throughout UPLC separation EE EE

25 MetaboLynx XS: 1 µm Human Liver Microsome Verapamil Incubation Samples Found Metabolites Combined Metabolites MS Spectrum Metabolite XIC of Metabolite XIC of Metabolite in Control Parent Drug Structure

26 MSMS Information Displayed in the Fragment Analysis Window. Product Ion Information Precursor Ion Information Neutral Loss Information

27 Verapamil Product Ion Spectrum Interpretation Ver0319_ (8.845) : TOF MS ES+ 4.15e m/z

28 MassFragment Structural Assignment

29 Verapamil Fragment Assignment to Structure Ver0319_ (8.845) mDa 2: TOF MS ES+ 4.15e5-0.1 mda -0.1 mda -0.5mDa -0.1mDa -0.0 mda m/z

30 Samples, Time Course

31 Metabolic Stability Plot

32 Alprazolam Quantitation Curve QuanTof Fully TargetLynx Compatible Alprazolam in PPT Plasma 3x Dev <20 at LOQ Dev <15 other

33 Alprazolam Quantitation Curve Absolute, Internal Standards: R 2 = R 2 = pg/ml 20 pg/ml to 200 ng/ml 200,000 pg/ml Relative Response Factors: Via Orthogonal Detection (UV, RAD)

34 Summary Xevo TQ-S and Xevo G2 QTof provide class leading instrument performance Innovative Technologies such as StepWave, ScanWave and QuanTof engineered to integrate into existing workflows and open paths to new workflows for comprehensive sample analysis and increased productivity LCMS Innovations to merge Quantitative and Qualitative analysis without compromising your analytical objectives

35 Acknowledgements Waters Corporation Paul Rainville Marian Twohig Joanne Mather Rob Plumb Kate Yu Henry Shion Steve McDonald Gordon Fujumoto Alan Millar Jeff Goshawk Alex Hooper Hoffman-LaRoche Zhenmin Liang Astra Zeneca, UK David Higton Dotmatics, LTD

36

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions Simplifying Qual/Quan Analysis in Discovery DMPK using UPLC and Xevo TQ MS Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION The determination of the drug metabolism

More information

INTRODUCTION CH 3 CH CH 3 3. C 37 H 48 N 6 O 5 S 2, molecular weight Figure 1. The Xevo QTof MS System.

INTRODUCTION CH 3 CH CH 3 3. C 37 H 48 N 6 O 5 S 2, molecular weight Figure 1. The Xevo QTof MS System. Fast and Sensitive in vitro Metabolism Study of Rate and Routes of Clearance for Ritonavir using UPLC CUPLED with the Xevo QTof MS System Jose Castro-Perez, Kate Yu, John Shockcor, Henry Shion, Emma Marsden-Edwards,

More information

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer

Rapid, Simple Impurity Characterization with the Xevo TQ Mass Spectrometer Robert Plumb, Michael D. Jones, and Marian Twohig Waters Corporation, Milford, MA, USA INTRODUCTION The detection and characterization of impurities and degradation products of an active pharmaceutical

More information

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution Joanne Mather, Steve Cubbedge, Debadeep Bhattacharya, and Robert S. Plumb Waters Corporation, Milford, MA, U.S. A P P L

More information

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Evelyn Goh Waters Pacific, Singapore APPLICATION BENEFITS This method allows for the simultaneous analysis of 12 water-soluble

More information

Chemical Analysis Business Operations Waters Corporation Milford MA

Chemical Analysis Business Operations Waters Corporation Milford MA The Detection and Identification of Unknown Contaminants During ToF Screening and Structural Elucidation for Pesticides in River Water Using an Integrated Software Approach Chemical Analysis Business Operations

More information

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1 Development of an SPE-LC/MS/MS Assay for the Simultaneous Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid in Support of Alzheimer s Research Dr. Erin E. Chambers Waters Corporation Presented

More information

Quantitation by High Resolution Mass Spectrometry: Case Study of TOF MS for the Quantitation of Allopurinol from Human Plasma

Quantitation by High Resolution Mass Spectrometry: Case Study of TOF MS for the Quantitation of Allopurinol from Human Plasma Quantitation by High Resolution Mass Spectrometry: Case Study of TOF MS for the Quantitation of Allopurinol from Human Plasma Shaokun Pang 1, Weixing Sun 2, Adrien Musuku 2, Xavier J. Misonne 1 1 SCIEX,

More information

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

[ APPLICATION NOTE ] High Sensitivity Intact Monoclonal Antibody (mab) HRMS Quantification APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS Yun Wang Alelyunas, Henry Shion, Mark Wrona Waters Corporation, Milford, MA, USA APPLICATION BENEFITS mab LC-MS method which enables users to achieve highly sensitive bioanalysis of intact trastuzumab

More information

Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK

Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK HIGH-THRUGHPUT REACTIVE METABLITE SCREEIG FR DICLFEAC BY UPLC AD XEV TQ MS WITH SCAWAVE Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford,

More information

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes

UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes UPLC/MS Monitoring of Water-Soluble Vitamin Bs in Cell Culture Media in Minutes Catalin E. Doneanu, Weibin Chen, and Jeffrey R. Mazzeo Waters Corporation, Milford, MA, U.S. A P P L I C AT ION B E N E F

More information

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS Mark Ritchie and Evelyn Goh Waters Pacific Pte Ltd., Singapore A P P L I C AT ION B E N E F I T S Delivers a rapid 10-min MRM method

More information

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis Ying Qing Yu Waters Corporation, Milford, MA, USA APPLICATION BENEFITS

More information

The Comparison of High Resolution MS with Triple Quadrupole MS for the Analysis of Oligonucleotides

The Comparison of High Resolution MS with Triple Quadrupole MS for the Analysis of Oligonucleotides The Comparison of High Resolution MS with Triple Quadrupole MS for the Analysis of Oligonucleotides Mohammed Abrar Unilabs York Bioanalytical Solutions Outline Introduction Why LC-MS/MS? Limitations of

More information

Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk

Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk Yoann Deceuninck 1, Emmanuelle Bichon 1, Paul Silcock 2, Fabrice Monteau

More information

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid Joanne ( 乔安妮 ) Mather Senior Scientist Waters Corporation Data courtesy of Erin Chambers and Mary

More information

Towards High Resolution MS in Regulated Bioanalysis

Towards High Resolution MS in Regulated Bioanalysis Towards High Resolution MS in Regulated Bioanalysis Benno Ingelse MSD 3 rd EB focus meeting June 12 th 13 th Brussels, Belgium Contributors Gary Adamson Ken Anderson Kevin Bateman Cynthia Chavez-Eng Inhou

More information

SYNAPT G2-S High Definition MS (HDMS) System

SYNAPT G2-S High Definition MS (HDMS) System SYNAPT G2-S High Definition MS (HDMS) System High performance, versatility, and workflow efficiency of your MS system all play a crucial role in your ability to successfully reach your scientific and business

More information

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research Stephen Balloch and Gareth Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS Analytical selectivity afforded by mass selective detection Wide linear measuring range Simple, inexpensive sample

More information

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations For Research Use Only. Not for use in diagnostic procedures. 1 2015 AB Sciex RUO-MKT-11-1018-A For research

More information

Analysis of drugs of abuse in biological matrix using Time of Flight technology

Analysis of drugs of abuse in biological matrix using Time of Flight technology Analysis of drugs of abuse in biological matrix using Time of Flight technology Niclas Stephanson, PhD Department of Clinical Pharmacology Karolinska University Hospital Karolinska Institutet Stockholm,

More information

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS [ APPLICATI TE ] Ion Mobility-enabled Data-dependent Experiments Distinguishing Co-eluting Isomeric Metabolites Using an IMS-QTof Mass Spectrometer Jayne Kirk, 1 Russell Mortishire Smith, 1 Robert Beecher,

More information

ACHIEVEMENTS ARE LIMITED ONLY BY ASPIRATIONS.

ACHIEVEMENTS ARE LIMITED ONLY BY ASPIRATIONS. ACHIEVEMENTS ARE LIMITED ONLY BY ASPIRATIONS. BE FIRST TO DISCOVER, TO PUBLISH, TO DEVELOP, TO SUCCEED. ENTER A NEW DIMENSION OF PERFORMANCE. Your success depends on your ability to optimize laboratory

More information

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research Dominic Foley, Michelle Wills, and Lisa Calton Waters Corporation, Wilmslow, UK APPLICATION

More information

Improving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer

Improving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer Improving Selectivity in Quantitative Analysis Using MS 3 on a Hybrid Quadrupole-Linear Ion Trap Mass Spectrometer Overview Increased selectivity is achieved in quantitative analysis by using MS 3. The

More information

CHARACTERIZATION AND DETECTION OF OLIVE OIL ADULTERATIONS USING CHEMOMETRICS

CHARACTERIZATION AND DETECTION OF OLIVE OIL ADULTERATIONS USING CHEMOMETRICS CHARACTERIZATION AND DETECTION OF OLIVE OIL ADULTERATIONS USING CHEMOMETRICS Paul Silcock and Diana Uria Waters Corporation, Manchester, UK AIM To demonstrate the use of UPLC -TOF to characterize and detect

More information

Reducing Sample Volume and Increasing Sensitivity for the Quantification of Human Insulin and 5 Analogs in Human Plasma Using ionkey/ms

Reducing Sample Volume and Increasing Sensitivity for the Quantification of Human Insulin and 5 Analogs in Human Plasma Using ionkey/ms Reducing Sample Volume and Increasing Sensitivity for the Quantification of Human Insulin and 5 Analogs in Human Plasma Using ionkey/ms Erin E. Chambers and Kenneth J. Fountain Waters Corporation, Milford,

More information

The New 6495 Triple Quadrupole LC/MS

The New 6495 Triple Quadrupole LC/MS The New 6495 Triple Quadrupole LC/MS Experience A New Level of Confidence Martin Haex Product Specialist MS and Automation 1 Overview of Topics The New 6495 QQQ LC/MS Technology Innovations Quantitation

More information

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS SCIEX QTRAP 4500 LC-MS/MS System and Spark Holland PICO Adrian M. Taylor 1, Peter Ringeling 2, Martin Sibum 2, Stefan Sturm

More information

High resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives

High resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives High resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives Lieve Dillen Drug Safety Sciences Analytical Sciences, Non-regulated Bioanalysis Presentation outline

More information

Method Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection

Method Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection Method Development for the Analysis of Endogenous Steroids Using Convergence Chromatography with Mass Spectrometric Detection Christopher J. Hudalla, Stuart Chadwick, Fiona Liddicoat, Andrew Peck, and

More information

PosterREPRINT RAPID, SELECTIVE SCREENING OF URINE SAMPLES FOR GLUCURONIDES BY LC/MS/MS INTRODUCTION ABSTRACT

PosterREPRINT RAPID, SELECTIVE SCREENING OF URINE SAMPLES FOR GLUCURONIDES BY LC/MS/MS INTRODUCTION ABSTRACT ABSTRACT The traditional study of in vivo drug metabolism in plasma or urine samples is often complicated by the presence of many endogenous compounds. Several mass spectrometric techniques are often applied

More information

Application Note # LCMS-89 High quantification efficiency in plasma targeted proteomics with a full-capability discovery Q-TOF platform

Application Note # LCMS-89 High quantification efficiency in plasma targeted proteomics with a full-capability discovery Q-TOF platform Application Note # LCMS-89 High quantification efficiency in plasma targeted proteomics with a full-capability discovery Q-TOF platform Abstract Targeted proteomics for biomarker verification/validation

More information

A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS.

A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS. A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS. Martin R Green*, Keith Richardson, John Chipperfield, Nick Tomczyk, Martin

More information

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS LC/MS/MS SOLUTIONS FOR LIPIDOMICS Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS Lipids play a key role in many biological processes, such as the formation of cell membranes and signaling

More information

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids

A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids A Definitive Lipidomics Workflow for Human Plasma Utilizing Off-line Enrichment and Class Specific Separation of Phospholipids Jeremy Netto, 1 Stephen Wong, 1 Federico Torta, 2 Pradeep Narayanaswamy, 2

More information

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Application Note Clinical Research Authors Derick Lucas and Limian Zhao Agilent Technologies, Inc. Abstract Lipids from

More information

Identification & Confirmation of Structurally Related Degradation Products of Simvastatin

Identification & Confirmation of Structurally Related Degradation Products of Simvastatin Identification & Confirmation of Structurally Related Degradation Products of Simvastatin Power of QTRAP Systems for Identification and Confirmation of Degradation Products Dilip Reddy 1, Chandra Sekar

More information

Development of a High Sensitivity SPE-LC-MS/MS Assay for the Quantification of Glucagon in Human Plasma Using the ionkey/ms System

Development of a High Sensitivity SPE-LC-MS/MS Assay for the Quantification of Glucagon in Human Plasma Using the ionkey/ms System Development of a High Sensitivity SPE-LC-MS/MS Assay for the Quantification of Glucagon in Human Plasma Using the ionkey/ms System Mary E. Lame, Erin E. Chambers, Sukhdev S. Bangar, and Kenneth J. Fountain

More information

LC-MS/MS Solutions for Comprehensive Cannabis Analysis

LC-MS/MS Solutions for Comprehensive Cannabis Analysis MODERN CANNABIS LC-MS/MS ANALYSIS TOTAL SOLUTION LC-MS/MS Solutions for Comprehensive Cannabis Analysis PIONEERING YOUR ANALYTICAL TESTING REQUIREMENTS Your Partner for LC-MS/MS Solutions for Cannabis

More information

Quantification of Budesonide Using UPLC and Xevo TQ-S

Quantification of Budesonide Using UPLC and Xevo TQ-S Tirupateswara Rao B., Sudarshan Mantha, and Gopal Vaidyanathan Waters India MS Application Laboratory, Bangalore, India A P P L I C AT ION B E N E F I T S This work demonstrates the benefits of the Regulated

More information

Supplementary Information

Supplementary Information Supplementary Information Molecular imaging of brain localization of liposomes in mice using MALDI mass spectrometry Annabelle Fülöp 1,2, Denis A. Sammour 1,2, Katrin Erich 1,2, Johanna von Gerichten 4,

More information

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF

Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF Impurity Identification using a Quadrupole - Time of Flight Mass Spectrometer QTOF PUSHER TOF DETECTOR ZSPRAY TM Ion Source SAMPLING CONE SKIMMER RF HEXAPOLE RF HEXAPOLE QUADRUPOLE IN NARROW BANDPASS MODE

More information

Moving from targeted towards non-targeted approaches

Moving from targeted towards non-targeted approaches Gesundheitsdirektion Moving from targeted towards non-targeted approaches Anton Kaufmann Official Food Control Authority of the Canton of Zurich () Switzerland 2 Overview I From single residue to multi

More information

Simultaneous Analysis of Intact Human Insulin and Five Analogs in Human Plasma Using μelution SPE and a CORTECS UPLC Column

Simultaneous Analysis of Intact Human Insulin and Five Analogs in Human Plasma Using μelution SPE and a CORTECS UPLC Column Simultaneous Analysis of Intact Human Insulin and Five Analogs in Human Plasma Using μelution SPE and a CORTECS UPLC Column Erin E. Chambers and Kenneth J. Fountain Waters Corporation, Milford, MA, USA

More information

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value

Agilent 6410 Triple Quadrupole LC/MS. Sensitivity, Reliability, Value Agilent 64 Triple Quadrupole LC/MS Sensitivity, Reliability, Value Sensitivity, Reliability, Value Whether you quantitate drug metabolites, measure herbicide levels in food, or determine contaminant levels

More information

Amadeo R. Fernández-Alba

Amadeo R. Fernández-Alba % of compounds % of compounds % of compounds % of compounds Amadeo R. Fernández-Alba LC-Orbitrap QExactive Focus Instrumental LOQ 1% 9% 8% 7% 6% 5% 4% 3% 2% 1% %.1 mg/g.2 mg/g Tomato.5 mg/g ddms2 Target

More information

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids Data Independent Acquisition on TripleTOF and X-Series QTOF Systems for Seized Drug Analysis Oscar G. Cabrices

More information

Made For Routine Food, Environment, and Forensic Testing

Made For Routine Food, Environment, and Forensic Testing Made For Routine Food, Environment, and Forensic Testing The X500R QTOF System Powered by SCIEX OS High resolution mass spec, in perfect balance It s Time You Were Heard For far too long you ve had to

More information

SEPARATION OF BRANCHED PFOS ISOMERS BY UPLC WITH MS/MS DETECTION

SEPARATION OF BRANCHED PFOS ISOMERS BY UPLC WITH MS/MS DETECTION SEPARATION OF BRANCHED PFOS ISOMERS BY UPLC WITH MS/MS DETECTION Marian Twohig 1, Nicholas Ellor 1, Keith Worrall 2, Tim Jenkins 2, Gordon Kearney 2 1 Waters Corporation, 1 Cummings Center, Beverly, MA

More information

A High Sensitivity UPLC/MS/MS Method for the Analysis of Clopidogrel and Clopidogrel Carboxylic Acid Metabolite in Human K 2 EDTA Plasma

A High Sensitivity UPLC/MS/MS Method for the Analysis of Clopidogrel and Clopidogrel Carboxylic Acid Metabolite in Human K 2 EDTA Plasma A High Sensitivity UPLC/MS/MS Method for the Analysis of Clopidogrel and Clopidogrel Carboxylic Acid Metabolite in Human K 2 EDTA Plasma Jennifer L. Simeone, Paul D. Rainville, Robert S. Plumb Waters Corporation,

More information

Small Molecule Science: Experimental designs for achieving ultra trace analysis

Small Molecule Science: Experimental designs for achieving ultra trace analysis Small Molecule Science: Experimental designs for achieving ultra trace analysis Michael P. Balogh Principal scientist Waters Corporation 211 Waters Corporation 1 www.cosmoscience.org The Society for Small

More information

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager

MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager MS/MS Library Creation of Q-TOF LC/MS Data for MassHunter PCDL Manager Quick Start Guide Step 1. Calibrate the Q-TOF LC/MS for low m/z ratios 2 Step 2. Set up a Flow Injection Analysis (FIA) method for

More information

A UPLC/MS Approach for the Diagnosis of Inborn Errors of Metabolism

A UPLC/MS Approach for the Diagnosis of Inborn Errors of Metabolism Elizabeth Want, 1 Stephen McDonald 2 1 Imperial College, London, UK 2 Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S UPLC /MS E was used to profile diagnostic metabolites in a

More information

Considerations of the use of Triple Quadrupoles or Ion Traps in Quantitative Applications

Considerations of the use of Triple Quadrupoles or Ion Traps in Quantitative Applications Considerations of the use of Triple Quadrupoles or Ion Traps in Quantitative Applications Triple Stage Quadrupole API MS / MS Full Scan Products / - IONS AND NEUTRALS FORMED IN API SOURCE Q0 LENS TRANSPORTS

More information

Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology. Ultra sensitive quantitative performance

Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology. Ultra sensitive quantitative performance Agilent 6490 Triple Quadrupole LC/MS System with ifunnel Technology Ultra sensitive quantitative performance Unmatched quantitative performance for the most challenging analyses The Agilent 6490 Triple

More information

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ Application Note Clinical Research Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ Authors Jennifer Hitchcock 1, Lauren Frick 2, Peter Stone 1, and Vaughn Miller 2 1 Agilent

More information

Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology

Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology Claude Mallet, 1 Jennifer Simeone, 2 Paul Rainville 3 1 Workflow Integration Group, Separations Technologies,

More information

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis Providing a Universal, ne-step Alternative to Liquid-Liquid Extraction in Bioanalysis Jessalynn P. Wheaton, Erin E. Chambers, and Kenneth J. Fountain APPLICATIN BENEFITS n Simple, one-step sample preparation

More information

Determination of Amantadine Residues in Chicken by LCMS-8040

Determination of Amantadine Residues in Chicken by LCMS-8040 Liquid Chromatography Mass Spectrometry Determination of Amantadine Residues in Chicken by LCMS-8040 A method for the determination of amantadine in chicken was established using Shimadzu Triple Quadrupole

More information

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Application Note LCMS-109 A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Time of Flight (LC-TOF) Mass Spectrometry Introduction Many clinical

More information

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these

More information

Fully Automated Online Sample Preparation AND Quantification of Amiodarone from Whole Blood using CLAM-LC-MS/MS

Fully Automated Online Sample Preparation AND Quantification of Amiodarone from Whole Blood using CLAM-LC-MS/MS PO-CON177E Fully Automated Online Sample Preparation AND Quantification of Amiodarone from Whole Blood using CLAM-LC-MS/MS ASMS 17 ThP 93 Christian Bunse 1, Lars Kröner 1 Shimadzu Deutschland GmbH, Duisburg,

More information

Fast, Robust and Reliable Method for the Identification and Quantitation of Sildenafil Residue in Honey using LC-MS/MS

Fast, Robust and Reliable Method for the Identification and Quantitation of Sildenafil Residue in Honey using LC-MS/MS Fast, Robust and Reliable Method for the Identification and Quantitation of Sildenafil Residue in Honey using LC-MS/MS Praveen K. Sharma 1, Neha Bhasin 1, Prasanth Joseph 1, Manoj G Pillai 1, and André

More information

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer A Robustness Study for the Agilent 7 LC-MS/MS Mass Spectrometer Application Note Clinical Research Authors Linda Côté, Siji Joseph, Sreelakshmy Menon, and Kevin McCann Agilent Technologies, Inc. Abstract

More information

Jody Dunstan, 1 Antonietta Gledhill, 1 Ailsa Hall, 2 Patrick Miller, 2 Christian Ramp 3. Waters Corporation, Manchester, UK 2

Jody Dunstan, 1 Antonietta Gledhill, 1 Ailsa Hall, 2 Patrick Miller, 2 Christian Ramp 3. Waters Corporation, Manchester, UK 2 Quantification of the Hormones Progesterone and Cortisol in Whale Breath Samples Using Novel, Non-Invasive Sampling and Analysis with Highly-Sensitive ACQUITY UPLC and Xevo TQ-S Jody Dunstan, 1 Antonietta

More information

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases

Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases Clinical, Forensic & Toxicology Applications Rapid and Accurate LC-MS/MS Analysis of Nicotine and Related Compounds in Urine Using Raptor Biphenyl LC Columns and MS-Friendly Mobile Phases By Shun-Hsin

More information

Technical Note # TN-31 Redefining MALDI-TOF/TOF Performance

Technical Note # TN-31 Redefining MALDI-TOF/TOF Performance Bruker Daltonics Technical Note # TN-31 Redefining MALDI-TOF/TOF Performance The new ultraflextreme exceeds all current expectations of MALDI-TOF/TOF technology: A proprietary khz smartbeam-ii TM MALDI

More information

Liquid Chromatograph Mass Spectrometer LCMS-8060 C146-E286

Liquid Chromatograph Mass Spectrometer LCMS-8060 C146-E286 Liquid Chromatograph Mass Spectrometer LCMS-8060 C146-E286 EVERYTHING Sensitivity Speed Solutions LCMS-8060 The LCMS-8060 pushes the limits of what we can see. Creating the future of LC/MS/MS analysis

More information

Discovery Metabolomics - Quantitative Profiling of the Metabolome using TripleTOF Technology

Discovery Metabolomics - Quantitative Profiling of the Metabolome using TripleTOF Technology ANSWERS FOR SCIENCE. KNOWLEDGE FOR LIFE. Discovery Metabolomics - Quantitative Profiling of the Metabolome using TripleTOF Technology Baljit Ubhi Ph.D ASMS Baltimore, June 2014 What is Metabolomics? Also

More information

Rapid Analysis of Bisphenols A, B, and E in Baby Food and Infant Formula Using ACQUITY UPLC with the Xevo TQD

Rapid Analysis of Bisphenols A, B, and E in Baby Food and Infant Formula Using ACQUITY UPLC with the Xevo TQD Rapid Analysis of Bisphenols A, B, and E in Baby Food and Infant Formula Using ACQUITY UPLC with the Xevo TQD Claude R. Mallet Waters Corporation, Milford, MA, USA A P P L I C AT ION B E N E F I T S This

More information

The Application of UPLC/MS E for the Analysis of Bile Acids in Biological Fluids

The Application of UPLC/MS E for the Analysis of Bile Acids in Biological Fluids The Application of UPLC/MS E for the Analysis of Bile Acids in Biological Fluids Elizabeth J. Want, 1 Muireann Coen, Perrine Masson, Hector C. Keun, Jake T.M. Pearce, Michael D. Reily, Donald Robertson,

More information

UPLC/MS/MS Method for the Routine Quantification of Regulated and Non-Regulated Lipophilic Marine Biotoxins in Shellfish

UPLC/MS/MS Method for the Routine Quantification of Regulated and Non-Regulated Lipophilic Marine Biotoxins in Shellfish UPLC/MS/MS Method for the Routine Quantification of Regulated and n-regulated Lipophilic Marine Biotoxins in Shellfish Arjen Gerssen, 1 Mirjam D. Klijnstra, 1 Simon Cubbon, 2 and Antonietta Gledhill 2

More information

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification 22 SEPARATION SCIENCE REDEFINED MAY 2005 Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification In the drug discovery process the detection and

More information

Data Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section

Data Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section Data Independent MALDI Imaging HDMS E for Visualization and Identification of Lipids Directly from a Single Tissue Section Emmanuelle Claude, Mark Towers, and Kieran Neeson Waters Corporation, Manchester,

More information

Paul D. Rainville Ph.D. Health Sciences Group Waters Corporation Waters Corporation 1

Paul D. Rainville Ph.D. Health Sciences Group Waters Corporation Waters Corporation 1 A new level of sensitivity and standardization: The promise of integrated micro fluidic devices coupled with mass spectrometry for the analysis of biofluids Paul D. Rainville Ph.D. Health Sciences Group

More information

LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods

LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods LC/MS/MS of Trichothecenes and Zearalenone in Wheat Using Different Sample Prep Methods Application Note Food Testing & Agriculture Authors Nick Byrd and Danielle Sweeney Campden BRI Gloucestershire UK

More information

UPLC-HRMS: A tool for multi-residue veterinary drug methods

UPLC-HRMS: A tool for multi-residue veterinary drug methods AOAC, Paris, November 23-24, 2009 UPLC-HRMS: A tool for multi-residue veterinary drug methods Anton Kaufmann Official Food Control Authority of the Canton of Zurich (Kantonales Labor Zürich) The challenge

More information

Liquid Chromatograph Mass Spectrometer LCMS-8050 C146-E232A

Liquid Chromatograph Mass Spectrometer LCMS-8050 C146-E232A Liquid Chromatograph Mass Spectrometer LCMS-85 C146-E232A Speed and Sensitivity Beyond Comparison Continuing the evolution of Shimadzu's UF technology, Shimadzu introduces the LCMS-85 triple quadrupole

More information

Ultra High Definition Optimizing all Analytical Dimensions

Ultra High Definition Optimizing all Analytical Dimensions Ultra High Definition Optimizing all Analytical Dimensions Sensitivity Dynamic Range Signal Response Linearity Separation Speed Peak Capacity Chromatogram Mass Spectrum Mass Accuracy Resolving Power Acquisition

More information

Detection of Cotinine and 3- hydroxycotine in Smokers Urine

Detection of Cotinine and 3- hydroxycotine in Smokers Urine Detection of Cotinine and 3- hydroxycotine in Smokers Urine Behavioural and Situational Research Group School of Medicine, University of Tasmania Version number: 2 Effective date: 01/12/2015 Review due:

More information

A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine

A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine PO-CON737E A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine ASMS 7 WP 353 Shao Hua Chia ; Zhi Wei Edwin Ting ; Daisuke Kawakami

More information

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids

Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids PO-CON1576E Comprehensive Two-Dimensional HPLC and Informative Data Processing for Pharmaceuticals and Lipids HPLC 2015 PSB-MULTI-06 Yoshiyuki WATABE, Tetsuo IIDA, Daisuke NAKAYAMA, Kanya TSUJII, Saki

More information

Simple Method (IS-MRM) to Monitor Lysophospholipids and Phospholipids During LC-MS Method Development via In-Source CID

Simple Method (IS-MRM) to Monitor Lysophospholipids and Phospholipids During LC-MS Method Development via In-Source CID Simple Method (IS-MRM) to Monitor Lysophospholipids and Phospholipids During LC-MS Method Development via In-Source CID James Little, Eastman Chemical Company, Kingsport, TN Overview Phospholipids and

More information

Extended Mass Range Triple Quadrupole for Routine Analysis of High Mass-to-charge Peptide Ions

Extended Mass Range Triple Quadrupole for Routine Analysis of High Mass-to-charge Peptide Ions Extended Mass Range Triple Quadrupole for Routine Analysis of High Mass-to-charge Peptide Ions Application Note Targeted Proteomics Authors Linfeng Wu, Christine A. Miller, Jordy Hsiao, Te-wei Chu, Behrooz

More information

Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of

Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of 4.1. Introduction Dry eye disease commonly known as atopic keratoconjunctivitis is an autoimmune disease of eyes. The disease is characterized by lesser or some time no-significant production of tear;

More information

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System

PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System Application Note LC/MS PTM Discovery Method for Automated Identification and Sequencing of Phosphopeptides Using the Q TRAP LC/MS/MS System Purpose This application note describes an automated workflow

More information

MALDI Imaging Drug Imaging Detlev Suckau Head of R&D MALDI Bruker Daltonik GmbH. December 19,

MALDI Imaging Drug Imaging Detlev Suckau Head of R&D MALDI Bruker Daltonik GmbH. December 19, MALDI Imaging Drug Imaging Detlev Suckau Head of R&D MALDI Bruker Daltonik GmbH December 19, 2014 1 The principle of MALDI imaging Spatially resolved mass spectra are recorded Each mass signal represents

More information

The Agilent MassHunter Software. One Software for all Agilent Mass Spec Systems

The Agilent MassHunter Software. One Software for all Agilent Mass Spec Systems The Agilent MassHunter Software One Software for all Agilent Mass Spec Systems MassHunter The most innovative MS SW! MassHunter Workstation One software for all Agilent MS Systems Minimize learning (and

More information

Quantification with Proteome Discoverer. Bernard Delanghe

Quantification with Proteome Discoverer. Bernard Delanghe Quantification with Proteome Discoverer Bernard Delanghe Overview: Which approach to use? Proteome Discoverer Quantification Method What When to use Metabolic labeling SILAC Cell culture systems Small

More information

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E

Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E Liquid Chromatograph Mass Spectrometer LCMS-8040 C146-E188E Ultra-High Sensitivity By incorporating newly improved ion optics and collision cell technology, the LCMS-8040 provides higher multiple reaction

More information

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine High-Throughput Quantitative LC-MS/MS Analysis of and 14 Benzodiazepines in Urine Bill Yu, Kristine Van Natta, Marta Kozak, Thermo Fisher Scientific, San Jose, CA Application Note 588 Key Words Opiates,

More information

[ APPLICATION NOTE ] UPLC-MS/MS Analysis of 45 Amino Acids Using the Kairos Amino Acid Kit for Biomedical Research INTRODUCTION APPLICATION BENEFITS

[ APPLICATION NOTE ] UPLC-MS/MS Analysis of 45 Amino Acids Using the Kairos Amino Acid Kit for Biomedical Research INTRODUCTION APPLICATION BENEFITS UPLC-MS/MS Analysis of 45 Amino Acids Using the Kairos Amino Acid Kit for Biomedical Research Padhraic Rossiter, 1 Jaime Salcedo Dominguez, 1 Jennifer Warren, 1 Norma Breen, 1 Lisa Calton 2 1 Waters Corporation,

More information

Sue D Antonio Application Chemist Cedar Creek, TX

Sue D Antonio Application Chemist Cedar Creek, TX Sue D Antonio Application Chemist Cedar Creek, TX What is Hemp Oil? CBD hemp oil is a natural botanical extract of the common hemp plant. CBD hemp oil is derived from the seeds and stem of the Cannabis

More information

[ APPLICATION NOTE ] A Generic Kit-Based Approach for LC-MS/MS Quantification of Urinary Albumin for Clinical Research APPLICATION BENEFITS

[ APPLICATION NOTE ] A Generic Kit-Based Approach for LC-MS/MS Quantification of Urinary Albumin for Clinical Research APPLICATION BENEFITS A Generic Kit-Based Approach for LC-MS/MS Quantification of Urinary Albumin for Clinical Research Mary Lame, Caitlin Dunning, and Erin Chambers Waters Corporation, Milford, MA, USA APPLICATION BENEFITS

More information

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer Abstract This study demonstrates a sensitive, rapid and reliable research

More information

ION MOBILITY COUPLED TO HIGH RESOLUTION MASS SPECTROMETRY: THE POSSIBILITIES, THE LIMITATIONS

ION MOBILITY COUPLED TO HIGH RESOLUTION MASS SPECTROMETRY: THE POSSIBILITIES, THE LIMITATIONS ION MOBILITY COUPLED TO HIGH RESOLUTION MASS SPECTROMETRY: THE POSSIBILITIES, THE LIMITATIONS Anton Kaufmann Official Food Control Authority of the Canton of Zurich (Kantonales Labor Zürich) Switzerland

More information

LC-MS/MS Method for the Determination of Tenofovir from Plasma

LC-MS/MS Method for the Determination of Tenofovir from Plasma LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract

More information

Increasing the Peak Capacity of LC/MS/MS Systems for the Analysis of Complex Biological Samples

Increasing the Peak Capacity of LC/MS/MS Systems for the Analysis of Complex Biological Samples Increasing the Peak Capacity of LC/MS/MS Systems for the Analysis of Complex Biological Samples Mark A. McDowall Pharmaceutical Discovery & Life Sciences Waters Corporation, Manchester, UK 2011 Waters

More information

Workflow for Screening and Quantification of the SAMHSA (NIDA) Panel in Urine Using UHPLC-TOF

Workflow for Screening and Quantification of the SAMHSA (NIDA) Panel in Urine Using UHPLC-TOF APPLICATIO OTE Liquid Chromatography/ Mass Spectrometry Authors: Avinash Dalmia Joanne Mather PerkinElmer, Inc. Shelton, CT Workflow for Screening and Quantification of the SAMHSA (IDA) Panel in Urine

More information