University of Tartu, Estonia Janssen Pharmaceutica NV, Belgium

Size: px
Start display at page:

Download "University of Tartu, Estonia Janssen Pharmaceutica NV, Belgium"

Transcription

1 Semiquantitative ESI/MS analysis of metabolites in biological matrices made feasible via prediction of ionization efficiencies Piia Liigand, Jaanus Liigand, Filip Cuyckens, Rob J. Vreeken, Anneli Kruve University of Tartu, Estonia Janssen Pharmaceutica NV, Belgium

2 Methoxychlor HPTE LC/MS Stable isotope labelled internal standards

3 Standard substance free quantitation Aldicarb 4-methoxypyridine ESI+ Aldicarb sulfoxide m/z 4-nitrophenol 2-methoxypyridine m/z m/z Salicylic acid ESI- 2-nitrophenol Benzoic acid m/z m/z 180 m/z

4 Signal Signal Ionization efficiencies C 1 = C 2 Signal m/z Signal 1 < Signal 2 8.E+07 6.E+07 4.E+07 C 1 < C 2 Ionization efficiency 2.E+07 0.E+00 4.E+07 0.E+00 5.E-06 1.E-05 2.E-05 2.E-05 3.E-05 Leito et al Rapid. Commun. Mass Spectrom 22 (2008) E+07 2.E+07 1.E+07 0.E+00 0.E+00 2.E-05 4.E-05 6.E-05 8.E-05 c (M) log IE = log slope 1 slope 2 c (M)

5 Predicted logie Modelling COSMOtherm 5 MS measurements 3 1 Physicochemical parameters log IE predicted = f x 1 x n -3 log IE measured = log slope 1 slope 2-5 Measured logie

6 Oss et al Anal. Chem. 82 (2010) ; Liigand et al Anal. Chem. 89 (2017) Predicted logie ESI /80 0.1% formic acid/acetonitrile 62 compounds: logp = -22 6; pk a (aq) = Mismatch 7 times log IE = α WANS Measured logie R 2 = 0.63 s = 0.87

7 Predicted logie ESI- 20/80 0.1% ammonia/acetonitrile logp = 1 18; pk a (aq) = Model development R 2 = 0.83 mismatch 2.5 times Validation mismatch 3 times log IE = α 0.51 WAPS -4 Measured logie benzoic acid phenol salicylic acid validation set Kruve et al Anal. Chem. 86 (2014)

8 c predicted (M) log IE (Sciex) logie Transferability between instruments 11 setups: 4 vendors, 3 ion sources, 5 mass-analyzers Order of IEs independent of the instrument R 2 = Anchoring is recommended (calibration compounds) Concentration mismatch lower than 2.5 times 1.0E Setup A Setup B Setup C Setup D 4 1.0E E E E E-05 c actual (M) Liigand et al J. Am. Soc. Mass Spectrom 26 (2015) y = 0.80x R² = log IE (Thermo)

9 c predicted (µm) logie predicted Transferability between solvents ESI- 10 solvent compositions 62 compounds Flow injection (0.2 ml/min) logie measured Validation with gradient LC/ESI/MS Mismatch 3.7 times (44 times without model) See poster WP 298 on Wednesday Kruve et al Anal. Chem. 89 (2017) c actual (µm)

10 Could this also work in biological matrices? O HO HO Benzoic acid Salicylic acid 3-CF 3 SO 2 -benzoic acid plasma blood liver tissue AUTOSAMPLER CSF Warfarin Naproxen Sorbic acid Dodecanoic acid Lincomycin Taurocholic acid Fumaric acid brain tissue urine 20/80 0.1% ammonia/acetonitrile Protein precipitation MS 1 ESI- Flow injection Liigand et al Anal. Chim. Acta (available online:

11 logie I. Measuring logie in matrices Warfarin Taurocholic acid 3-CF 3 SO 2 -benzoic acid Salicylic acid Dodecanoic acid Benzoic acid Naproxen Lincomycin Sorbic acid Fumaric acid Urine Plasma Blood CSF Liver Brain Solvent Liigand et al Anal. Chim. Acta (available online:

12 logie I. Measuring logie in matrices Warfarin Taurocholic acid 3-CF 3 SO 2 -benzoic acid Salicylic acid Dodecanoic acid Benzoic acid Naproxen Lincomycin Sorbic acid Fumaric acid Urine Plasma Blood CSF Liver Brain Solvent Liigand et al Anal. Chim. Acta (available online:

13 logie I. Measuring logie in matrices 2 Warfarin 90% signal suppressed 0-4 Warfarin Taurocholic acid 3-CF 3 SO 2 -benzoic acid Salicylic acid Urine Solvent Dodecanoic acid Benzoic acid Naproxen Lincomycin Sorbic acid Fumaric acid Fumaric acid -2 99% signal suppressed Blood Solvent Urine Plasma Blood CSF Liver Brain Solvent Liigand et al Anal. Chim. Acta (available online:

14 II. Correlation with neat solvent Urine Plasma Blood logie urine logie plasma y = 1.80x y = 2.15x 1.74 y = 2.10x R² = R² = R² = 0.71 logie solv logie solv logie solv logie blood CSF Liver Brain logie CSF logie liver y = 1.42x R² = logie solv logie solv y = 1.40x 1.01 R² = logie solv Liigand et al Anal. Chim. Acta (available online: logie brain y = 1.37x 0.80 R² = 0.87

15 III. Model development COSMOtherm log IE = a WAPS + b α + c WAPS pk a α s LOO mismatch... Leave-one-out cross validation MLR Liigand et al Anal. Chim. Acta (available online:

16 Predicted logie III. Model to predict logie log IE = coef WAPS WAPS + coef α α + intercept 2 coef WAPS coef α intercept R 2 mismatch Solvent Urine Plasma Blood Liver Brain CSF Liigand et al Anal. Chim. Acta (available online: Measured logie SOLVENT PLASMA URINE BLOOD LIVER BRAIN CSF -4 R 2 = times mismatch

17 Standard substance free quantitation log IE blood = 0.50 WAPS α Ionization logie (benzoic acid) = Signal (benzoic acid) = logie (salicylic acid) = Signal (salicylic acid) = efficiency c(salicylic acid) c(benzoic acid) = signal (salicylic acid) signal(benzoic acid) IE(salicylic acid) IE(benzoic acid) Salicylic acid c(salicylic acid) c(benzoic acid) = 8x mismatch Benzoic acid m/z

18 Proof-of-concept Approach works! ESI+ and ESI-, different setups, different mobile phases, biological matrices C of calibration compounds 2D structure of compound of interest MS 1 signal Poster WP 298 Wednesday Technical aspects Software (automation) LC, adducts More matrices (environmental, food, botanics) Self-improving How can you use it? IE prediction model Concentration estimate

19 Conclusion Predicting ESI ionization efficiencies Different ESI modes Different mobile phase compositions Transferable between different instruments Biological matrices Semiquantitative analysis prediction mismatch 8 times

20 Poster WP 298 on Wednesday Thank you! Kruvelab.com

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System

Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System Automated Purification and Analytical Reinjection of a Small Molecule Drug, Probenecid, on a Gilson LC/MS Dual Function System Keywords Introduction Application Note PHA0413 High Pressure Liquid Chromatography

More information

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography

Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography Profiling of Endogenous Metabolites Using Time-of-Flight LC/MS with Ion Pair Reverse Phase Chromatography Application Note Metabolomics Author Yuqin Dai Agilent Technologies, Inc. 31 Stevens Creek Blvd,

More information

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Application Note: 346 MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Gargi Choudhary and Diane Cho, Thermo Fisher Scientific, San Jose, CA Wayne Skinner and

More information

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System Marta Kozak Clinical Research Applications Group Thermo Fisher Scientific San Jose CA Clinical Research use only, Not for

More information

Title: Pharmacokinetics of daikenchuto, a traditional Japanese medicine (Kampo) after. single oral administration to healthy Japanese volunteers

Title: Pharmacokinetics of daikenchuto, a traditional Japanese medicine (Kampo) after. single oral administration to healthy Japanese volunteers Title: Pharmacokinetics of daikenchuto, a traditional Japanese medicine (Kampo) after single oral administration to healthy Japanese volunteers Authors: Masaya Munekage, Hiroyuki Kitagawa, Kengo Ichikawa,

More information

Direct Analysis of Folic Acid in Digestive Juices by LC/TOF-MS Application

Direct Analysis of Folic Acid in Digestive Juices by LC/TOF-MS Application Direct Analysis of Folic Acid in Digestive Juices by LC/TOF-MS Application Food Safety Authors M. H. Blokland, P. W. Zoontjes, S. S. Sterk, and L. A. van Ginkel, National Institute of Public Health and

More information

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices

Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices Application ote #LCMS-2 esquire series Application of LC/Electrospray Ion Trap Mass Spectrometry for Identification and Quantification of Pesticides in Complex Matrices Introduction The simple monitoring

More information

A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS.

A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS. A NOVEL METHOD OF M/Z DRIFT CORRECTION FOR OA-TOF MASS SPECTROMETERS BASED ON CONSTRUCTION OF LIBRARIES OF MATRIX COMPONENTS. Martin R Green*, Keith Richardson, John Chipperfield, Nick Tomczyk, Martin

More information

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa

Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa Reduced Ion Suppression and Improved LC/MS Sensitivity with Agilent Bond Elut Plexa Application Note Small Molecule Pharmaceuticals & Generics Author Mike Chang Agilent Technologies, Inc. 5 Commercentre

More information

Determination of Unbound Urinary Amino Acids Incorporated with Creatinine Normalization by LC-MS/MS Method with CLAM-2000 Online Sample Pre-treatment

Determination of Unbound Urinary Amino Acids Incorporated with Creatinine Normalization by LC-MS/MS Method with CLAM-2000 Online Sample Pre-treatment PO-CON133E Determination of Unbound Urinary Amino Acids Incorporated with Creatinine Normalization by LC-MS/MS Method with CLAM-2000 Online Sample Pre-treatment ASMS 201 WP 34 Zhe Sun 1, Jie Xing 1, Ei

More information

A FORENSIC TOXICOLOGY METHOD FOR THE DETERMINATION OF DESOMORPHINE, HEROIN, METHADONE, BUPRENORPHINE AND METABOLITES IN URINE USING LC/MS QQQ

A FORENSIC TOXICOLOGY METHOD FOR THE DETERMINATION OF DESOMORPHINE, HEROIN, METHADONE, BUPRENORPHINE AND METABOLITES IN URINE USING LC/MS QQQ FORENSICS MARKET A FORENSIC TOXICOLOGY METHOD FOR THE DETERMINATION OF DESOMORPHINE, HEROIN, METHADONE, BUPRENORPHINE AND METABOLITES IN URINE USING LC/MS QQQ Desomorphine, also known by its street name

More information

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation Valérie Thibert, Bénédicte Duretz Thermo Fisher Scientific, Courtaboeuf,

More information

Edgar Naegele. Abstract

Edgar Naegele. Abstract Simultaneous determination of metabolic stability and identification of buspirone metabolites using multiple column fast LC/TOF mass spectrometry Application ote Edgar aegele Abstract A recent trend in

More information

LCMS-8030 Application Report. Steroids: Testosterone, Progesterone, Estradiol, Ethinylestradiol

LCMS-8030 Application Report. Steroids: Testosterone, Progesterone, Estradiol, Ethinylestradiol LCMS-8030 Application Report Steroids: Testosterone, Progesterone, Estradiol, Ethinylestradiol Summary: Sensitivity was tested for four steroids on the LCMS-8030 triple quadrupole mass spectrometer coupled

More information

An Alternative Approach: Top-Down Bioanalysis of Intact Large Molecules Can this be part of the future? Lecture 8, Page 27

An Alternative Approach: Top-Down Bioanalysis of Intact Large Molecules Can this be part of the future? Lecture 8, Page 27 An Alternative Approach: Top-Down Bioanalysis of Intact Large Molecules Can this be part of the future? Lecture 8, Page 27 Top-down HRAM Bioanalysis of Native Proteins/Molecules Relative Abundance 100

More information

Targeted and untargeted metabolic profiling by incorporating scanning FAIMS into LC-MS. Kayleigh Arthur

Targeted and untargeted metabolic profiling by incorporating scanning FAIMS into LC-MS. Kayleigh Arthur Targeted and untargeted metabolic profiling by incorporating scanning FAIMS into LC-MS Kayleigh Arthur K.Arthur@lboro.ac.uk Introduction LC-MS is a highly used technique for untargeted profiling analyses

More information

Abstract. Introduction

Abstract. Introduction A Fast Dilute-And-Shoot Method for Simultaneous 5-Hydroxyindoleacetic Acid (5-HIAA), Vanillylmandelic Acid (VMA), and Homovanillic Acid (HVA) LC-MS/MS Analysis in Human Urine By Shun-Hsin Liang and Sue

More information

A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine

A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine PO-CON737E A Novel Platform of On-line Sample Pre-treatment and LC/MS/MS Analysis for Screening and Quantitation of Illicit Drugs in Urine ASMS 7 WP 353 Shao Hua Chia ; Zhi Wei Edwin Ting ; Daisuke Kawakami

More information

Summary Chapter 8 CHAPTER 8. Summary. Page 173

Summary Chapter 8 CHAPTER 8. Summary. Page 173 CHAPTER 8 Summary Page 173 Chapter 2: Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitative Estimation of PEG 400 and its Applications A rapid sensitive and selective MRM based method

More information

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Evelyn Goh Waters Pacific, Singapore APPLICATION BENEFITS This method allows for the simultaneous analysis of 12 water-soluble

More information

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS

Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS Rapid Lipid Profiling of Serum by Reverse Phase UPLC-Tandem Quadrupole MS Mark Ritchie and Evelyn Goh Waters Pacific Pte Ltd., Singapore A P P L I C AT ION B E N E F I T S Delivers a rapid 10-min MRM method

More information

The Analysis of Jojoba Oil by LC-Coordination Ion Spray-MS (LC-CIS-MS)

The Analysis of Jojoba Oil by LC-Coordination Ion Spray-MS (LC-CIS-MS) The Analysis of Jojoba Oil by LC-Coordination Ion Spray-MS (LC-CIS-MS) K. Lazou 1, A. d Oosterlinck 2, L. De Reu 1, M. Schelfaut 2, and P. Sandra 2 * 1 Department of Chemical Quality Control, Janssen Pharmaceutica,

More information

Maria João Mendes Mendonça Barreira Department of Health Promotion and Chronic Deseases, INSA

Maria João Mendes Mendonça Barreira Department of Health Promotion and Chronic Deseases, INSA Quantification of four immunosuppressant drugs by Liquid Chomatography-Tandem Mass Spectrometry using Direct Injection. Maria João Mendes Mendonça Barreira Department of Health Promotion and Chronic Deseases,

More information

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Xiang He 1, Adrian Taylor 2 and Alexandre Wang 1 1 SCIEX, Redwood City, USA. 2 SCIEX, Concord,

More information

Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase

Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase Subhra Bhattacharya and Stephen C. Roemer Thermo Fisher Scientific Global Chemicals, Fair Lawn, NJ, USA AbstrAct Liquid

More information

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer application Note Liquid Chromatography/ Mass Spectrometry Authors Sharanya Reddy Blas Cerda PerkinElmer, Inc. Shelton, CT USA Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate

More information

Application Note: 425. Introduction. Goal. Experimental Conditions

Application Note: 425. Introduction. Goal. Experimental Conditions Application Note: 425 Determination of Different Classes of Pesticide Residues in Processed Fruits and Vegetables by LC-MS Using the TSQ Quantum Ultra According to EU Directive 91/414 EEC Eleni Botitsi,

More information

Analysis of Choline and its Metabolites on the Finnigan LTQ

Analysis of Choline and its Metabolites on the Finnigan LTQ Analysis of Choline and its Metabolites on the Finnigan LTQ Gargi Choudhary Diane Cho Thermo Electron, San Jose, CA Abstracted from a poster presented at Montreux 3 LC/MS Symposium, with co-authors: Brad

More information

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS

application Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS application LC/MS Natural Food Colorants Analysis of Natural Food Colorants by Electrospray and Atmospheric Pressure Chemical Ionization LC/MS Introduction Many kinds of natural colors are used in beverages,

More information

Author. Introduction. Small Molecule Pharmaceuticals & Generics

Author. Introduction. Small Molecule Pharmaceuticals & Generics Agilent Bond Elut Plexa PCX Cation Exchange SPE A Destination to a Better Sensitivity in LC/MS Bioanalysis Resulting from Minimized Ion-Suppression Application Note Small Molecule Pharmaceuticals & Generics

More information

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification

Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification 22 SEPARATION SCIENCE REDEFINED MAY 2005 Ultra Performance Liquid Chromatography Coupled to Orthogonal Quadrupole TOF MS(MS) for Metabolite Identification In the drug discovery process the detection and

More information

Lipidomic Analysis by UPLC-QTOF MS

Lipidomic Analysis by UPLC-QTOF MS Lipidomic Analysis by UPLC-QTOF MS Version: 1 Edited by: Oliver Fiehn Summary Reagents and Materials Protocol Summary:Lipidomic analysis by UPLC-QTOF mass spectrometry Reagents and Materials: Reagent/Material

More information

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis

Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis Applying a Novel Glycan Tagging Reagent, RapiFluor-MS, and an Integrated UPLC-FLR/QTof MS System for Low Abundant N-Glycan Analysis Ying Qing Yu Waters Corporation, Milford, MA, USA APPLICATION BENEFITS

More information

Dienes Derivatization MaxSpec Kit

Dienes Derivatization MaxSpec Kit Dienes Derivatization MaxSpec Kit Item No. 601510 www.caymanchem.com Customer Service 800.364.9897 Technical Support 888.526.5351 1180 E. Ellsworth Rd Ann Arbor, MI USA TABLE OF CONTENTS GENERAL INFORMATION

More information

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA

More information

High resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives

High resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives High resolution mass spectrometry for bioanalysis at Janssen. Current experiences and future perspectives Lieve Dillen Drug Safety Sciences Analytical Sciences, Non-regulated Bioanalysis Presentation outline

More information

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions Simplifying Qual/Quan Analysis in Discovery DMPK using UPLC and Xevo TQ MS Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION The determination of the drug metabolism

More information

Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system

Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 6410 Triple Quadrupole LC/MS system Quantification of lovastatin in human plasma by LC/ESI/MS/MS using the Agilent 641 Triple Quadrupole LC/MS system Application Note Clinical Research Author Siji Joseph Agilent Technologies Bangalore, India

More information

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine J. Jones, S. Westwood, T. Liddicoat, L. Pereira, T. Edge Thermo Fisher Scientific, Manor Park, Runcorn, UK Overview Purpose:

More information

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Application Note Clinical Research Authors Derick Lucas and Limian Zhao Agilent Technologies, Inc. Abstract Lipids from

More information

Oxysterol Derivatization MaxSpec Kit

Oxysterol Derivatization MaxSpec Kit Oxysterol Derivatization MaxSpec Kit Item No. 601540 www.caymanchem.com Customer Service 800.364.9897 Technical Support 888.526.5351 1180 E. Ellsworth Rd Ann Arbor, MI USA TABLE OF CONTENTS GENERAL INFORMATION

More information

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W

Shuguang Li, Jason Anspach, Sky Countryman, and Erica Pike Phenomenex, Inc., 411 Madrid Ave., Torrance, CA USA PO _W Simple, Fast and Accurate Quantitation of Human Plasma Vitamins and Their Metabolites by Protein Precipitation Combined with Columns Using HPLC-UV, HPLC-FLD or LC/MS/MS Shuguang Li, Jason Anspach, Sky

More information

Application Note. Abstract. Authors. Pharmaceutical

Application Note. Abstract. Authors. Pharmaceutical Analysis of xycodone and Its Metabolites-oroxycodone, xymorphone, and oroxymorphone in Plasma by LC/MS with an Agilent ZRBAX StableBond SB-C18 LC Column Application ote Pharmaceutical Authors Linda L.

More information

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants Jeremy Matthews, 1 Alex Chen, 2 and Flavio Bedini 1 1 Thermo Fisher Scientific, Singapore; 2 Alpha Analytical Pte Ltd, Singapore Overview

More information

ACE C18-AR Use the Power!

ACE C18-AR Use the Power! combines the retention and separation characteristics of a C18 phase with the extra selectivity of an integral phenyl functional group. The combination provides extra resolving power for a wide variety

More information

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1.

Run 1 Run 2 TDP PLP TDP PLP. 3.0e5 2.8e5 2.2e5. 2.6e5 2.4e5. 2.2e5 2.0e5. Intensity, cps. 1.8e5 1.6e5 1.4e5 1.2e5 1.0e5 4.0e4. 2.0e e5 1. APPLICATIONS A Simple and Effective High ph LC/MS/MS Method for Determination of Underivatized Vitamin B1 and B6 in Human Whole Blood Ramkumar Dhandapani Technical Manager Ramkumar loves to write poems,

More information

Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS. Peio RISS ICP-MS Application Specialist.

Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS. Peio RISS ICP-MS Application Specialist. Enhanced Detection Capabilities in Speciation Analysis Using a Highly Sensitive ICP-MS Peio RISS ICP-MS Application Specialist aurora Elite Bruker ICP-MS aurora series The aurora series design All-digital

More information

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column Clinical, Forensic & Toxicology Applications 4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column By Amanda Rigdon Abstract A rapid, sensitive method

More information

Analysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo, Nihon Waters, JAPAN

Analysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo, Nihon Waters, JAPAN Waters Alliance LC/MS System Analytical Conditions Chromatograms Mass Spectra Calibration Quantitation Analysis of Pesticides (II) Metribuzin & their metabolites in Rice Jun Yonekubo,, JAPAN Key Words

More information

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer A Robustness Study for the Agilent 7 LC-MS/MS Mass Spectrometer Application Note Clinical Research Authors Linda Côté, Siji Joseph, Sreelakshmy Menon, and Kevin McCann Agilent Technologies, Inc. Abstract

More information

Removal of Triton X-100 from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE)

Removal of Triton X-100 from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE) Removal of Triton X- from Plasma Samples Using Mixed-Mode Solid Phase Extraction (SPE) Jonathan P. Danaceau, Erin Chambers, and Kenneth J. Fountain Waters Corporation, 34 Maple Street, Milford, MA USA

More information

High-Throughput Analysis of Oligonucleotides using Automated Electrospray Ionization Mass Spectrometry

High-Throughput Analysis of Oligonucleotides using Automated Electrospray Ionization Mass Spectrometry High-Throughput Analysis of Oligonucleotides using Automated Electrospray Ionization Mass Spectrometry Mark E. Hail 1, Brian Elliott 2, Kerry Nugent 3, Jeffrey L. Whitney 1, and David J. Detlefsen 1 1

More information

The setup and validation of an LC-MS/MS assay of Androstenedione & Testosterone a labs experience

The setup and validation of an LC-MS/MS assay of Androstenedione & Testosterone a labs experience The setup and validation of an LC-MS/MS assay of Androstenedione & Testosterone a labs experience Keith Mulready Specialist Senior Medical Scientist Why measure Testosterone? Hypogonadism in Males Cancer

More information

Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement

Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement Separation of Polyphenols by Comprehensive 2D-LC and Molecular Formula Determination by Coupling to Accurate Mass Measurement Application Note Food Testing & Agriculture Author Edgar Naegele Agilent Technologies,

More information

for the Identification of Phosphorylated Peptides

for the Identification of Phosphorylated Peptides Application of a Data Dependent Neutral-Loss Experiment on the Finnigan LTQ for the Identification of Phosphorylated Peptides Gargi Choudhary Diane Cho Thermo Electron, San Jose, CA Abstracted from posters

More information

Noora Perkola Finnish Environment Institute. Nordic MS Symposium November 9, 2011, Båstad, Sweden

Noora Perkola Finnish Environment Institute. Nordic MS Symposium November 9, 2011, Båstad, Sweden Noora Perkola Finnish Environment Institute Nordic MS Symposium November 9, 2011, Båstad, Sweden Artificial Sweeteners Used as additives in various food products to replace sugar 4 non-caloric sweeteners

More information

SUPPLEMENTARY INFORMATION

SUPPLEMENTARY INFORMATION SUPPLEMENTARY INFORMATION Sex-specific metabolic profiles of androgens and its main binding protein SHBG in a middle aged population without diabetes Uwe Piontek, Henri Wallaschofski, Gabi Kastenmüller,

More information

Overview of Matrix Effects in Bioanalysis

Overview of Matrix Effects in Bioanalysis Overview of Matrix Effects in Bioanalysis Patrick Bennett & Jing Tu PPD Laboratories 31March2017 Outline 1. Definitions 2. Overview of Matrix Effects 3. Regulatory guidance on matrix effect(s): FDA and

More information

Challenges in Separation Technologies

Challenges in Separation Technologies Challenges in Separation Technologies Erin Shammel Baker Xing Zhang, Yehia Ibrahim, Matthew Monroe, Dennis Mehinagic, Justin Teeguarden, Thomas Metz and Richard D. Smith Pacific Northwest National Laboratory

More information

Impact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids

Impact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids Impact of Reversed-Phase Chiral Chromatography on the LC-MS Analysis of Drugs in Biological Fluids David S. Bell, Carmen T. Santasania, Jennifer Claus, Wayne K. Way, and Craig R. Aurand Supelco, Div. of

More information

Vitamin D3 and related compounds by ESI and APCI

Vitamin D3 and related compounds by ESI and APCI Liquid Chromatography Mass Spectrometry SSI-LCMS-9 Vitamin D and related compounds by ESI and APCI LCMS-8 Summary Vitamin D and related compounds were measured by LC-ESI/APCI-MS-MS. Background Accurate

More information

Determination of Multi-Residue Tetracyclines and their Metabolites in Milk by High Performance Liquid Chromatography - Tandem Mass Spectrometry

Determination of Multi-Residue Tetracyclines and their Metabolites in Milk by High Performance Liquid Chromatography - Tandem Mass Spectrometry Determination of Multi-Residue Tetracyclines and their Metabolites in Milk by igh Performance Liquid Chromatography - Tandem Mass Spectrometry Application ote Food Authors Yanyan Fang, ao Zhai, and Yun

More information

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution

Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution Matrix Factor Determination with the Waters Regulated Bioanalysis System Solution Joanne Mather, Steve Cubbedge, Debadeep Bhattacharya, and Robert S. Plumb Waters Corporation, Milford, MA, U.S. A P P L

More information

Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK

Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford, MA, U.S. and Manchester, UK HIGH-THRUGHPUT REACTIVE METABLITE SCREEIG FR DICLFEAC BY UPLC AD XEV TQ MS WITH SCAWAVE Jose Castro-Perez, Henry Shion, Kate Yu, John Shockcor, Emma Marsden-Edwards, Jeff Goshawk Waters Corporation, Milford,

More information

Analysis of Limonin in Citrus Juice Using QuEChERS and LC-MS/MS

Analysis of Limonin in Citrus Juice Using QuEChERS and LC-MS/MS Analysis of Limonin in Citrus Juice Using QuEChERS and LC-MS/MS UCT Part Numbers ECQUEU7-MP Mylar pouch containing 4g MgSO4, 1g NaCl, 1g Na3Cit 2H2O and 0.5g Na2Cit 1.5H2O CUMPSC1875CB2CT 2mL dspe tube

More information

Two-Dimensional LC/MS/MS to Reduce Ion Suppression in the Determination of Cannabinoids in Blood Plasma

Two-Dimensional LC/MS/MS to Reduce Ion Suppression in the Determination of Cannabinoids in Blood Plasma Two-Dimensal LC/MS/MS to Reduce Ion Suppress in the Determinat of Cannabinoids in Blood Plasma Applicat Note Forensic Toxicology Authors Gerd Vanhoenacker, Mieke Steenbeke, Koen Sandra, and Pat Sandra

More information

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS

New Solvent Grade Targeted for Trace Analysis by UHPLC-MS New Solvent Grade Targeted for Trace Analysis by UHPLC-MS Subhra Bhattacharya, Deva H. Puranam, and Stephen C. Roemer Thermo Fisher Scientific Fisher Chemical, One Reagent Lane, Fair Lawn, NJ Material

More information

Time-of-Flight LC/MS Identification and Confirmation of a Kairomone in Daphnia magna Cultured Medium. Application. Authors. Abstract.

Time-of-Flight LC/MS Identification and Confirmation of a Kairomone in Daphnia magna Cultured Medium. Application. Authors. Abstract. Time-of-Flight LC/MS Identification and Confirmation of a Kairomone in Daphnia magna Cultured Medium Application Natural Product Chemistry Authors Hideaki Uchida Agilent Technologies Japan, Ltd. Tokyo

More information

Analytical Challenges in Veterinary Toxicology: Bromethalin

Analytical Challenges in Veterinary Toxicology: Bromethalin Analytical Challenges in Veterinary Toxicology: Bromethalin Mike Filigenzi, Birgit Puschner, Linda Aston, Robert Poppenga CAHFS-UC Davis School of Veterinary Medicine First things first: Acknowledgements

More information

Unique Retention and Selectivity of Pentafluorophenylpropyl Phases for High-Throughput LC/MS Analysis

Unique Retention and Selectivity of Pentafluorophenylpropyl Phases for High-Throughput LC/MS Analysis Unique Retention and Selectivity of Pentafluorophenylpropyl Phases for High-Throughput LC/MS Analysis David S. Bell Supelco, Bellefonte, PA ASMS 22 T42119 (xxx) Overview 2 The LC/MS retention and sensitivity

More information

Ion fragmentation of small molecules in mass spectrometry

Ion fragmentation of small molecules in mass spectrometry Ion fragmentation of small molecules in mass spectrometry Jeevan Prasain jprasain@uab.edu 6-2612 Nomenclature: the main names and acronyms used in mass spectrometry Molecular ion: Ion formed by addition

More information

IC-MS Environmental Applications - Water Testing. Application Notebook

IC-MS Environmental Applications - Water Testing. Application Notebook IC-MS Environmental Applications - Water Testing Application Notebook Table of Contents Environmental Sample Using IC-MS 3 Environmental Applications: Water Testing Acrylamide in Water 4 Trace Urea in

More information

Analysis of Polar Pesticides Using a Mixed-Phase Mode HPLC Column

Analysis of Polar Pesticides Using a Mixed-Phase Mode HPLC Column Analysis of Polar Pesticides Using a Mixed-Phase Mode HPLC Column Narong Chamkasem, Southeast Food and Feed Laboratory (SFFL), U.S. Food and Drug Administration, Atlanta, GA Disclaimer The findings and

More information

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No.

Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection. EPL-BAS Method No. Page 1 of 10 Determination of 6-Chloropicolinic Acid (6-CPA) in Crops by Liquid Chromatography with Tandem Mass Spectrometry Detection EPL-BAS Method No. 205G881B Method Summary: Residues of 6-CPA are

More information

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ Application Note Clinical Research Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ Authors Jennifer Hitchcock 1, Lauren Frick 2, Peter Stone 1, and Vaughn Miller 2 1 Agilent

More information

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ

LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ LC-MS/MS analysis of Chlorates in Milk and Whey Powder using the Agilent 6470 QQQ Anthony Sullivan, LC/MS Product Specialist Melanie Mülek and Christoph Müller LC-MS Applications Specialists Hewlett-Packard-Str.

More information

LC/MS Method for Comprehensive Analysis of Plasma Lipids

LC/MS Method for Comprehensive Analysis of Plasma Lipids Application Note omics LC/MS Method for Comprehensive Analysis of Plasma s Authors Tomas Cajka and Oliver Fiehn West Coast Metabolomics Center, University of California Davis, 451 Health Sciences Drive,

More information

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids

SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids SWATH Acquisition Enables the Ultra-Fast and Accurate Determination of Novel Synthetic Opioids Data Independent Acquisition on TripleTOF and X-Series QTOF Systems for Seized Drug Analysis Oscar G. Cabrices

More information

LCMS Vitamin D3 Method development

LCMS Vitamin D3 Method development LCMS-85 Vitamin D3 Method development Background Vitamin D3 Analysis is in demand in SAP region especially in Singapore and India Clinical Diagnostics and Clinical Research is demanding this application

More information

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine High-Throughput Quantitative LC-MS/MS Analysis of and 14 Benzodiazepines in Urine Bill Yu, Kristine Van Natta, Marta Kozak, Thermo Fisher Scientific, San Jose, CA Application Note 588 Key Words Opiates,

More information

Pilot experiments to investigate the glucuronidation of axitinib with human liver microsomes.

Pilot experiments to investigate the glucuronidation of axitinib with human liver microsomes. Zientek MA, Goosen TC, Tseng E, Lin J, Bauman JN, Walker GS, Kang P, Jiang Y, Freiwald S, Neul D and Smith BJ. In Vitro Kinetic Characterization of Axitinib Metabolism. Drug Metab Dispos. Supplemental

More information

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D

LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D LC/MS Analysis of Various Hydrophilic Compounds Using a Polymer-Based Amino Column - Shodex TM HILICpak TM VG-50 2D Introduction Components of pharmaceutical products and food products often include high

More information

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS [ APPLICATI TE ] Ion Mobility-enabled Data-dependent Experiments Distinguishing Co-eluting Isomeric Metabolites Using an IMS-QTof Mass Spectrometer Jayne Kirk, 1 Russell Mortishire Smith, 1 Robert Beecher,

More information

Author. Introduction. Abstract

Author. Introduction. Abstract Simultaneous Measurement of Sirolimus and Tacrolimus Concentrations in Blood by Semi-Automated Extraction and Liquid Chromatography-Electrospray Ionization Mass Spectrometry Application Author Gary L.

More information

Development and Validation of a Liquid Chromatography- Mass Spectrometry method for analysis of Oxysterols in Human Plasma

Development and Validation of a Liquid Chromatography- Mass Spectrometry method for analysis of Oxysterols in Human Plasma 1 Development and Validation of a Liquid Chromatography- Mass Spectrometry method for analysis of Oxysterols in Human Plasma Rohini Narayanaswamy University At Buffalo, The State University of New York

More information

Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection

Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with LC/MS Detection Application Note Food Testing, Metabolomics, Agricultural Chemistry, Environmental Quantitative Analysis of Underivatized Amino Acids in Plant Matrix by Hydrophilic Interaction Chromatography (HILIC) with

More information

Fully Automated Online Sample Preparation AND Quantification of Amiodarone from Whole Blood using CLAM-LC-MS/MS

Fully Automated Online Sample Preparation AND Quantification of Amiodarone from Whole Blood using CLAM-LC-MS/MS PO-CON177E Fully Automated Online Sample Preparation AND Quantification of Amiodarone from Whole Blood using CLAM-LC-MS/MS ASMS 17 ThP 93 Christian Bunse 1, Lars Kröner 1 Shimadzu Deutschland GmbH, Duisburg,

More information

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System

Mass-Based Purification of Natural Product Impurities Using an Agilent 1260 Infinity II Preparative LC/MSD System Application Note Food Testing and Agriculture Mass-Based Purification of Natural Product Impurities Using an Agilent 126 Infinity II Preparative LC/MSD System Authors Florian Rieck and Jörg Hippler Agilent

More information

Supplementary Information. Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a

Supplementary Information. Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a Supplementary Information Effects of Perfluorooctanoic Acid on Metabolic Profiles in Brain and Liver of Mouse by a High-throughput Targeted Metabolomics Approach Nanyang Yu, Si Wei, *, Meiying Li, Jingping

More information

Workflow for Screening and Quantification of the SAMHSA (NIDA) Panel in Urine Using UHPLC-TOF

Workflow for Screening and Quantification of the SAMHSA (NIDA) Panel in Urine Using UHPLC-TOF APPLICATIO OTE Liquid Chromatography/ Mass Spectrometry Authors: Avinash Dalmia Joanne Mather PerkinElmer, Inc. Shelton, CT Workflow for Screening and Quantification of the SAMHSA (IDA) Panel in Urine

More information

Authors. Abstract. Introduction. Environmental

Authors. Abstract. Introduction. Environmental Determination of Ultratrace Amitrol in Water Samples by in situ Derivatization-Solid Phase Extraction-Liquid Chromatography-Mass Selective Detector Application Environmental Authors Gerd Vanhoenacker,

More information

Institute of Toxicology Clinical Toxicology and Pharmacology Berliner Betrieb für Zentrale Gesundheitliche Aufgaben, Berlin

Institute of Toxicology Clinical Toxicology and Pharmacology Berliner Betrieb für Zentrale Gesundheitliche Aufgaben, Berlin LOGO Institute of Toxicology Clinical Toxicology and Pharmacology Berliner Betrieb für Zentrale Gesundheitliche Aufgaben, Berlin Rapid Quantification of Tilidine, Nortilidine and Bisnortilidine in Urine

More information

Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes

Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes Using Hydrophilic Interaction Chromatography (HILIC) for the Retention of Highly Polar Analytes Eric S. Grumbach,, Diane M. Diehl and Jeffrey R. Mazzeo 2003 Waters Corp. Outline Introduction HILIC Definition

More information

27 November p. 01

27 November p. 01 p. 01 The fairy-tale of a multi-analyte LC/MS/MSassay for quantification of low pg/ml levels of active drug compounds and metabolites of a topical fixed dose combination product. Vibeke H. Sunesen & Morten

More information

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies.

Using Software Tools to Improve the Detection of Impurities by LC/MS. Application Note. Christine Miller Agilent Technologies. Using Software Tools to Improve the Detection of Impurities Application Note Christine Miller Introduction The analysis of raw materials and finished products for or impurities presents a challenge in

More information

Application of a new capillary HPLC- ICP-MS interface to the identification of selenium-containing proteins in selenized yeast

Application of a new capillary HPLC- ICP-MS interface to the identification of selenium-containing proteins in selenized yeast Application of a new capillary HPLC- ICP-MS interface to the identification of selenium-containing proteins in selenized yeast Application note Food supplements Authors Juliusz Bianga and Joanna Szpunar

More information

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research Stephen Balloch and Gareth Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS Analytical selectivity afforded by mass selective detection Wide linear measuring range Simple, inexpensive sample

More information

Measuring Lipid Composition LC-MS/MS

Measuring Lipid Composition LC-MS/MS Project: Measuring Lipid Composition LC-MS/MS Verification of expected lipid composition in nanomedical controlled release systems by liquid chromatography tandem mass spectrometry AUTHORED BY: DATE: Sven

More information

LC-MS Analysis of Botanicals

LC-MS Analysis of Botanicals Botanical workshop UAB, Sept 11, 26 LC-MS Analysis of Botanicals Jeevan K. Prasain, Ph.D. Department of Pharmacology & Toxicology, UAB Purdue-UAB Botanicals Center for Age-related Disease Applications

More information

LC-MS/MS for the quantification of Peptide biomarker and mixture of closely related Protein in formulation

LC-MS/MS for the quantification of Peptide biomarker and mixture of closely related Protein in formulation EUROPEAN BIOANALYSIS FORUM Barcelona, November 14-16, 2012 LC-MS/MS for the quantification of Peptide biomarker and mixture of closely related Protein in formulation Luc-Alain SAVOY CONTENT Part I: SGS

More information