LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

Size: px
Start display at page:

Download "LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine"

Transcription

1 LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine J. Jones, S. Westwood, T. Liddicoat, L. Pereira, T. Edge Thermo Fisher Scientific, Manor Park, Runcorn, UK

2 Overview Purpose: An LC-MS/MS method for the extraction of 21 opiates and opiate derivatives from urine is demonstrated in this poster. Method: Using a cation exchange SPE method, sample preparation is fast and reproducible giving excellent recovery levels for each compound. The analysis is carried out on a polar endcapped C18 column. The method presented provides chromatographic separation of the isobaric metabolites of morphine, morphine-3beta-dglucuronide, morphine-6beta-d-glucuronide and hydromorphone-3beta-d-glucuronide, which exhibit the same MRM transitions. Results: The method shows good accuracy and precision with %RSD less than 6.2% for all compounds. The compound recovery is in the range of %, with LOQs ranging from ng/ml. Introduction Opiates such as morphine and codeine are naturally occurring alkaloids found in the poppy plant. Semisynthetic opioids, such as hydrocodone, hydromorphone, oxycodone and oxymorphone, and fully-synthetic, such as fentanyl, methadone and tramadol, are derivatives of opiates but not classified as opiates themselves. Opiates are most commonly used in pain relief, particularly in palliative care to alleviate severe and chronic pain associated with terminal conditions. However, misuse of opiates for recreational use is also common due to the side effects such as sedation and euphoria. An initial method for the quantification of opiates from biological matrix used GC-MS. This required the conversion of the glucuronide conjugates to the free form via acid or enzyme hydrolysis, followed by post extraction derivatization. This approach was not only expensive and time consuming, but it is also difficult to ensure complete hydrolysis [1]. LC-MSMS, not only eliminates the necessity of derivatization, but the chromatographic separation and sensitivity achieved also allows for the successful quantification of the free and conjugated species. In order to extract opiates from the urine matrix for quantitative studies, an approach that can be taken is Solid Phase Extraction (SPE). The extraction detailed here is carried out using Thermo Scientific TM SOLA TM SCX. SOLA is a revolutionary SPE device, which provides an unparalleled performance in terms of reproducibility, extract cleanliness and sensitivity compared to conventional SPE, phospholipid and protein precipitation products. The US Substance Abuse and Mental Health Services Administration (SAMHSA) have established limits for most of the opiates at 2000 ng/ml [2]. However, raised levels of opiates or opiates derivatives have been reported in samples which were sourced from a subject which had consumed poppy seeds from bakery goods. Therefore, the range has been extended for this screening assay to ensure fewer false negatives. Methods 2 LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

3 fewer false negatives Methods Sample Pretreatment A standard spiking solution of 21opiates was prepared in methanol. A working internal standard solution of 12 deuterated opiates was prepared in methanol. 180 µl of blank urine was added to 800 µl of 1% formic acid in water. For standards and quality control (QC) samples, 10 µl of standard spiking solution was added, for blanks 10 µl of methanol was added. For standards and QCs 10 µl of working internal standard solution was added and for blanks 10 µl of methanol was added. All samples were vortexed for 30 seconds and then centrifuged for 5 minutes at 5000 rpm. Sample Preparation Plate type: SOLA SCX 10 mg / 2 ml Conditioning stage: 500 µl methanol then 500 µl water Application stage: 1000 µl of sample at approximately 1 ml/min Washing stage 1: 500 µl 1% formic acid in water Washing stage 2: 500 µl 1% formic acid in methanol Elution stage: 2 x 250 µl methanol / acetonitrile / triethylamine (45:45:10 v/v) Dry down under nitrogen without heat and reconstitute in 200 µl 0.1% formic acid in water. Mix well. Liquid Chromatography Instrumentation: Thermo Scientific TM Accela TM 600 LC system Column: Thermo Scientific TM Hypersil GOLD TM aq, 3 µm, 100 x 4.6 mm Mobile phase A: Water + 0.1% formic acid Mobile phase B: Methanol + 0.1% formic acid Flow rate: 1 ml/min Column temperature: 30 C Injection volume: 20 µl Injection wash solvent 1: Water Injection wash solvent 2: 45:45:10 (v/v/v) IPA / acetonitrile / acetone Thermo Scientific Poster Note PN20815_e 06/13S 3

4 TABLE 1. LC gradient conditions. Time (minutes) % A % B Mass Spectrometry Instrumentation: Thermo Scientific TM TSQ Vantage Triple Stage Quadrupole Mass Spectrometer TABLE 2. TSQ Vantage TM conditions. Ionization conditions HESI Polarity Positive Spray voltage (V) 4000 Vaporiser temperature ( C) 450 Sheath gas pressure (Arb) 40 Aux gas pressure (Arb) 25 Capillary temp ( C) 275 Collision pressure (mtorr) 1.5 Scan time (s) Q1 (FWHM) 0.7 Q3 (FWHM) 0.7 TABLE 3. Compound transition details. Parent S-Lens Quantifier (m/z) (V) (m/z) Compound 4 LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine Qualifier (m/z) Collision Energies (V) Quantifier, Qualifier normeperidine ,13 norfentanyl , 35 meperidine , 20 O-desmethyltramadol , 41 cis-tramadol , 46 EDDP , 23 norhydrocodone , 36 morphine , 25 hydromorphone , 40 hydrocodone , 38 codeine , 41 oxymorphone , 28 noroxycodone , 24 methadone , 27 oxycodone , 28 fentanyl , 37 morphine-3beta-dglucuronide , 42 morphine-6beta-dglucuronide , 40 hydromorphone-3beta- D-glucuronide , 47 codeine-6beta-dglucuronide , 25 oxymorphone-3beta-dglucuronide , 41 fentanyl D , 38 codeine D , 43 hydromorphone D , 41 methadone D , 28 morphine D , 40 norhydrocodone D , 36 noroxycodone D , 24 oxycodone D , 28 cis-tramadol D , 35 meperidine D , 20 hydrocodone D , 39 oxymorphone D , 29

5 Compound confirmation by ion ratio was achieved for each analyte over the specified concentration range. The % target ratio of qualifier ion to quantifier ion was attained during method development and set in the quantification method. Results Separation of all the isobaric metabolites was achieved using a C18 polar endcapped column. The polar group provides a controlled interaction mechanism by which polar compounds can be retained and resolved, and enables the use of 100% aqueous mobile phase at the gradient start. The separation of the glucuronide metabolites of morphine (3 and 6 position) and also the hydromorphone were baseline resolved and is demonstrated in Figure 1. Figure 2 shows an example chromatogram obtained at the LOQ for fentanyl, demonstrating the sensitivity of the assay. Opiate standards extracted from urine gave linear calibration curves over the dynamic range as specified for each compound (Table 4). QC samples were run in replicates of six at a concentration of 30, 150 and 300 ng/ml. Accuracy was assessed at each standard and QC level, all data points were within ±15% or ±20% at the LLOQ. Table 4 shows the mean relative error (%) for QCM (n=6). The precision at each of the QC levels for each of the 21 compounds is less than 6.2% RSD. Overspikes were analyzed in triplicate at concentrations of 15, 250 and 600 ng/ml and used to calculate recovery. The overall percentage recovery level was calculated using the average recovery at the three QC levels, and was greater than 83% for all compounds (Table 4). Thermo Scientific Poster Note PN20815_e 06/13S 5

6 FIGURE 1. Representative chromatogram of morphine- 6beta-D-glucuronide (1), hydromorphone-3beta-dglucuronide (2) and morphine-3beta-d-glucuronide (3) SRM, extracted from urine at 500 ng/ml. FIGURE 2. Representative chromatogram of fentanyl SRM, extracted from urine at 0.2 ng/ml. TABLE 4. Dynamic range, coefficient of determination, accuracy, precision and recovery data for extracted opiate and opiate derivative standards. Compound Linearity Range (ng/ml) Coefficient of Mean determination Relative Error (%) at QCM (n=6) (%RSD) QCM at 150 ng/ml (n=6) % Recovery normeperidine norfentanyl meperidine O-desmethyltramadol cis-tramadol EDDP norhydrocodone morphine hydromorphone hydrocodone codeine oxymorphone noroxycodone methadone oxycodone fentanyl morphine-3beta-dglucuronide morphine-6beta-dglucuronide hydromorphone-3beta- D-glucuronide codeine-6beta-dglucuronide oxymorphone-3beta-dglucuronide LC-MS/MS Method for the Determination of 21 Opiates and Opiate Derivatives in Urine

7 -D-glucuronide Conclusion SOLA SCX SPE plates and a Hypersil GOLD aq HPLC column allows for a simple extraction and rapid quantification of 21 opiates or opiate derivatives from urine using multiple internal standards. A Hypersil GOLD aq HPLC column provided the chromatographic separation of the isobaric metabolites of morphine, morphine-3beta-d-glucuronide, morphine-6beta-d-glucuronide and hydromorphone-3beta- D-glucuronide which exhibit the same MRM transitions. LOQs ranged from ng/ml for all compounds. Extraction recoveries for each compound was in the range of %. The method showed excellent accuracy and precision with %RSD less than 6.2% for all compounds. The ion ratio criteria were achieved at each standard and QC level for each compound. References 1. Wang P., Stone J.A., Chen K.H., Gross S.F., Haller C.A., Wu A.H. Incomplete recovery of prescription opioids in urine using enzymatic hydrolysis of glucuronide metabolites. Journal of Analytical Toxicology 2006; 30: SAMHSA (2010) Manual for Urine Laboratories, National Laboratory Certification Program, 1 October U.S Department of Health and Human Services Thermo Fisher Scientific Inc. All rights reserved. ISO is a trademark of the International Standards Organization. All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries. This information is presented as an example of the capabilities of Thermo Fisher Scientific Inc. products. It is not intended to encourage use of these products in any manners that might infringe the intellectual property rights of others. Specifications, terms and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details. Thermo Fisher Scientific, Sunnyvale, CA USA is ISO 9001:2008 Certified. Australia Austria Belgium Brazil China Denmark France Germany India Italy Japan Korea Netherlands Singapore Sweden Switzerland Taiwan UK/Ireland USA and Canada PN20815_E 06/13S

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine

SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine SPE-LC-MS/MS Method for the Determination of Nicotine, Cotinine, and Trans-3-hydroxycotinine in Urine J. Jones, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 709 Key Words SPE, SOLA

More information

LC-MS/MS Method for the Determination of Tenofovir from Plasma

LC-MS/MS Method for the Determination of Tenofovir from Plasma LC-MS/MS Method for the Determination of Tenofovir from Plasma Kimberly Phipps, Thermo Fisher Scientific, Runcorn, Cheshire, UK Application Note 687 Key Words SPE, SOLA CX, Hypersil GOLD, tenofovir Abstract

More information

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine

High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring Buprenorphine and Norbuprenorphine in Urine High-Throughput, Cost-Efficient LC-MS/MS Forensic Method for Measuring and in Urine Xiaolei Xie, Joe DiBussolo, Marta Kozak; Thermo Fisher Scientific, San Jose, CA Application Note 627 Key Words, norbuprenorphine,

More information

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation

Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation Quantitative Analysis of THC and Main Metabolites in Whole Blood Using Tandem Mass Spectrometry and Automated Online Sample Preparation Valérie Thibert, Bénédicte Duretz Thermo Fisher Scientific, Courtaboeuf,

More information

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine

High-Throughput Quantitative LC-MS/MS Analysis of 6 Opiates and 14 Benzodiazepines in Urine High-Throughput Quantitative LC-MS/MS Analysis of and 14 Benzodiazepines in Urine Bill Yu, Kristine Van Natta, Marta Kozak, Thermo Fisher Scientific, San Jose, CA Application Note 588 Key Words Opiates,

More information

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS

Fast and easy separation of 23 drugs of abuse. including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS TECHNICAL NOTE 21883 Fast and easy separation of 23 drugs of abuse including high, stable resolution of isobaric opioids from human urine by UHPLC-MS/MS Authors Kean Woodmansey 1, Jon Bardsley 1 and Stacy

More information

LC-MS/MS Method for the Determination of Raloxifene and its Glucuronide Metabolites from Human Plasma Using SPE Micro Elution

LC-MS/MS Method for the Determination of Raloxifene and its Glucuronide Metabolites from Human Plasma Using SPE Micro Elution LC-MS/MS Method for the Determination of Raloxifene and its Glucuronide Metabolites from Human Plasma Using SPE Micro Elution Krishna Rao Dara, Dr. Tushar N. Mehta, Centre of Excellence for Asia Pacific

More information

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis

The Investigation of Factors Contributing to Immunosuppressant Drugs Response Variability in LC-MS/MS Analysis The Investigation of Factors Contributing to Immunosuppressant Drugs Variability in LC-MS/MS Analysis Joseph Herman, Dayana Argoti, and Sarah Fair Thermo Fisher Scientific, Franklin, MA, USA Overview Purpose:

More information

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites

Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites Evaluation of an LC-MS/MS Research Method for the Analysis of 33 Benzodiazepines and their Metabolites Valérie Thibert 1, Norbert Dirsch 2, Johannes Engl 2, Martin Knirsch 2 1 Thermo Fisher Scientific,

More information

Direct Analysis of Urinary Opioids and Metabolites by Mixed-Mode µelution SPE Combined with UPLC/MS/MS for Forensic Toxicology

Direct Analysis of Urinary Opioids and Metabolites by Mixed-Mode µelution SPE Combined with UPLC/MS/MS for Forensic Toxicology Direct Analysis of Urinary Opioids and Metabolites by Mixed-Mode µelution SPE Combined with UPLC/MS/MS for Forensic Toxicology Jonathan P. Danaceau, Erin E. Chambers, and Kenneth J. Fountain Waters Corporation,

More information

Dayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA

Dayana Argoti, Kerry Hassell, Sarah J. Fair, and Joseph Herman Thermo Fisher Scientific, Franklin, MA, USA The Utilization of Novel Platform in a LC-MS/MS Workflow for the Analysis of Vitamin D, Testosterone, Immunosuppressants, Chemotherapeutics and Cortisol Dayana Argoti, Kerry Hassell, Sarah J. Fair, and

More information

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants

GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants GC-MS/MS Analysis of Benzodiazepines Using Analyte Protectants Jeremy Matthews, 1 Alex Chen, 2 and Flavio Bedini 1 1 Thermo Fisher Scientific, Singapore; 2 Alpha Analytical Pte Ltd, Singapore Overview

More information

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine

MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Application Note: 346 MS/MS as an LC Detector for the Screening of Drugs and Their Metabolites in Race Horse Urine Gargi Choudhary and Diane Cho, Thermo Fisher Scientific, San Jose, CA Wayne Skinner and

More information

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS

Robust extraction, separation, and quantitation of structural isomer steroids from human plasma by SPE-UHPLC-MS/MS TECHNICAL NOTE 21882 Robust extraction, separation, and quantitation of structural isomer steroids human plasma by SPE-UHPLC-MS/MS Authors Jon Bardsley 1, Kean Woodmansey 1, and Stacy Tremintin 2 1 Thermo

More information

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS

A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS A Comprehensive Screening of Illicit and Pain Management Drugs from Whole Blood Using SPE and LC/MS/MS Introduction Drug analysis from whole blood is gaining popularity due to a more complete measurement

More information

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA

Measuring Phytosterols in Health Supplements by LC/MS. Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA Measuring Phytosterols in Health Supplements by LC/MS Marcus Miller and William Schnute Thermo Fisher Scientific, San Jose, CA, USA Overview Purpose: Develop a method for the extraction of phytosterols

More information

Impurity Profiling of Carbamazepine by HPLC/UV

Impurity Profiling of Carbamazepine by HPLC/UV Application Note: 52049 Impurity Profiling of Carbamazepine by HPLC/UV Terry Zhang, Guifeng Jiang, Thermo Fisher Scientific, San Jose, CA, USA Key Words Accela Hypersil GOLD Carbamazepine Drug Analysis

More information

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography

A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Application Note LCMS-109 A Simple and Accurate Method for the Rapid Quantitation of Drugs of Abuse in Urine Using Liquid Chromatography Time of Flight (LC-TOF) Mass Spectrometry Introduction Many clinical

More information

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS)

High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) High Throughput Extraction of Opiates from Urine and Analysis by GC/MS or LC/MS/MS) Michael Rummel, Matthew Trass, Michael Campognone, and Sky Countryman Phenomenex, Inc., 411 Madrid Avenue, Torrance,

More information

Testing robustness: Immunosuppressant drugs in blood with a TSQ Quantis MS for clinical research

Testing robustness: Immunosuppressant drugs in blood with a TSQ Quantis MS for clinical research TEHNIL NOTE 64969 Testing robustness: Immunosuppressant drugs in blood with a TSQ Quantis MS for clinical research uthors Kristine Van Natta, Neloni Wijeratne, laudia Martins Thermo Fisher Scientific,

More information

Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D

Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D Comparison of Full Scan MS2 and MS3 Linear Ion Trap Approaches for Quantitation of Vitamin D Julie A. Horner 1, Marta Kozak 1, Subodh Nimkar 1, and August A. Specht 1 1 Thermo Fisher Scientific, San Jose,

More information

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS

Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS Bioanalytical Quantitation of Biotherapeutics Using Intact Protein vs. Proteolytic Peptides by LC-HR/AM on a Q Exactive MS Jenny Chen, Hongxia Wang, Zhiqi Hao, Patrick Bennett, and Greg Kilby Thermo Fisher

More information

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics

Quantitative Analysis of Opiates in Urine Using RRHT LC/MS/MS. Application. Authors. Introduction. Abstract. Forensics Quantitative Analysis of piates in Urine Using RRHT LC/MS/MS Application Forensics Authors Sheher Mohsin Agilent Technologies, Inc. 10 N. Martingale Rd., Suite 550 Schaumburg, IL 60173 USA Yanan Yang Agilent

More information

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis

Providing a Universal, One-step Alternative to Liquid-Liquid Extraction in Bioanalysis Providing a Universal, ne-step Alternative to Liquid-Liquid Extraction in Bioanalysis Jessalynn P. Wheaton, Erin E. Chambers, and Kenneth J. Fountain APPLICATIN BENEFITS n Simple, one-step sample preparation

More information

Detection and Quantification of Inorganic Arsenic in Fruit Juices by Capillary Ion Chromatography with Suppressed Conductivity Detection

Detection and Quantification of Inorganic Arsenic in Fruit Juices by Capillary Ion Chromatography with Suppressed Conductivity Detection Detection and Quantification of Inorganic Arsenic in Fruit Juices by Capillary Ion Chromatography with Suppressed Conductivity Detection Hua Yang, Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA

More information

Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase

Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase Enhanced LC-MS Sensitivity of Vitamin D Assay by Selection of Appropriate Mobile Phase Subhra Bhattacharya and Stephen C. Roemer Thermo Fisher Scientific Global Chemicals, Fair Lawn, NJ, USA AbstrAct Liquid

More information

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System

Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System Quantitative Analysis of Vit D Metabolites in Human Plasma using Exactive System Marta Kozak Clinical Research Applications Group Thermo Fisher Scientific San Jose CA Clinical Research use only, Not for

More information

LCMS-8050 Drugs of Abuse: 113 Analytes with Polarity Switching

LCMS-8050 Drugs of Abuse: 113 Analytes with Polarity Switching Liquid Chromatography Mass Spectrometry SSI-LCMS-8 LCMS-8 Drugs of Abuse: Analytes with Polarity Switching LCMS-8 Summary Seventy six analytes and their internal standards are described below. Multiple

More information

Robust and Fast Analysis of Tobacco-Specific Nitrosamines by LC-MS/MS

Robust and Fast Analysis of Tobacco-Specific Nitrosamines by LC-MS/MS Application Note 242 Robust and Fast Analysis of Tobacco-Specific Nitrosamines by LC-MS/MS INTRODUCTION Tobacco-specific nitrosamines (TSNA) are a group of carcinogens found only in tobacco products. They

More information

Determination of Amantadine Residues in Chicken by LCMS-8040

Determination of Amantadine Residues in Chicken by LCMS-8040 Liquid Chromatography Mass Spectrometry Determination of Amantadine Residues in Chicken by LCMS-8040 A method for the determination of amantadine in chicken was established using Shimadzu Triple Quadrupole

More information

A FORENSIC TOXICOLOGY METHOD FOR THE DETERMINATION OF DESOMORPHINE, HEROIN, METHADONE, BUPRENORPHINE AND METABOLITES IN URINE USING LC/MS QQQ

A FORENSIC TOXICOLOGY METHOD FOR THE DETERMINATION OF DESOMORPHINE, HEROIN, METHADONE, BUPRENORPHINE AND METABOLITES IN URINE USING LC/MS QQQ FORENSICS MARKET A FORENSIC TOXICOLOGY METHOD FOR THE DETERMINATION OF DESOMORPHINE, HEROIN, METHADONE, BUPRENORPHINE AND METABOLITES IN URINE USING LC/MS QQQ Desomorphine, also known by its street name

More information

Use of a Tandem Mass Spectrometry Research Method for the Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots

Use of a Tandem Mass Spectrometry Research Method for the Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots Use of a Tandem Mass Spectrometry Research Method for the Analysis of Amino Acids and Acylcarnitines in Dried Blood Spots Xiaolei Xie and Marta Kozak Thermo Fisher Scientific, San Jose, CA, USA Application

More information

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS

A RAPID AND SENSITIVE ANALYSIS METHOD OF SUDAN RED I, II, III & IV IN TOMATO SAUCE USING ULTRA PERFORMANCE LC MS/MS A RAPID AD SESITIVE AALYSIS METD OF SUDA RED I, II, III & IV I TOMATO SAUCE USIG ULTRA PERFORMACE LC MS/MS Choon Keow G, aomi TAAKA, Michelle KIM, Swee Lee YAP Waters Asia, Regional Technology Center,

More information

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis

Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE. SLE+ Prior to LC/MS-MS Analysis Application Note AN890 Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE SLE+ Page Extraction of a Comprehensive Steroid Panel from Human Serum Using ISOLUTE SLE+ Prior to LC/MS-MS

More information

Validation of an Automated Method to Remove

Validation of an Automated Method to Remove Shahana Wahab Huq 1, Richard Thomas 2, Agnes Cua 2, Seyed Sadjadi 1 1 Phenomenex, 411 Madrid Avenue, Torrance, CA 951 2 Precision Toxicology, 33 Bunker Hill Street, San Diego, CA 9219 Validation of an

More information

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN784 Extraction of Multiple Mycotoxins from Nuts Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Nuts Using ISOLUTE Myco prior to LC-MS/MS Analysis This application note

More information

Application Note. Abstract. Authors. Pharmaceutical

Application Note. Abstract. Authors. Pharmaceutical Analysis of xycodone and Its Metabolites-oroxycodone, xymorphone, and oroxymorphone in Plasma by LC/MS with an Agilent ZRBAX StableBond SB-C18 LC Column Application ote Pharmaceutical Authors Linda L.

More information

Agilent Clinical LC/MS: Review of Established LC-MS QQQ Clinical Research Applications. dr. Jan Srbek, HPST. Page 1

Agilent Clinical LC/MS: Review of Established LC-MS QQQ Clinical Research Applications. dr. Jan Srbek, HPST. Page 1 Agilent Clinical LC/MS: Review of Established LC-MS QQQ Clinical Research Applications dr. Jan Srbek, HPST Page 1 Major LC-MS Clinical Applications Steroids/Endocrinology Vitamin D Testosterone, Estradiol

More information

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer

A Robustness Study for the Agilent 6470 LC-MS/MS Mass Spectrometer A Robustness Study for the Agilent 7 LC-MS/MS Mass Spectrometer Application Note Clinical Research Authors Linda Côté, Siji Joseph, Sreelakshmy Menon, and Kevin McCann Agilent Technologies, Inc. Abstract

More information

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry

Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry Determination of β2-agonists in Pork Using Agilent SampliQ SCX Solid-Phase Extraction Cartridges and Liquid Chromatography-Tandem Mass Spectrometry Application Note Food Safety Authors Chenhao Zhai Agilent

More information

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS

DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS FORENSICS AND TOXICOLOGY ANALYSIS DETERMINATION OF CANNABINOIDS, THC AND THC-COOH, IN ORAL FLUID USING AN AGILENT 6490 TRIPLE QUADRUPOLE LC/MS Solutions for Your Analytical Business Markets and Applications

More information

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research

Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research Analysis of Testosterone, Androstenedione, and Dehydroepiandrosterone Sulfate in Serum for Clinical Research Dominic Foley, Michelle Wills, and Lisa Calton Waters Corporation, Wilmslow, UK APPLICATION

More information

Increased Identification Coverage and Throughput for Complex Lipidomes

Increased Identification Coverage and Throughput for Complex Lipidomes Increased Identification Coverage and Throughput for Complex Lipidomes Reiko Kiyonami, David Peake, Yingying Huang, Thermo Fisher Scientific, San Jose, CA USA Application Note 607 Key Words Q Exactive

More information

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs

Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis of Basic Drugs Seyed Sadjadi, Shahana Huq, Sean Orlowicz and Laura Snow Phenomenex, Inc., 411 Madrid Ave., Torrance, CA 90501 USA Comparison of Different Whole Blood Sample Pretreatment Methods for Targeted Analysis

More information

Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE. PLD+ Prior to LC-MS/MS Analysis

Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE. PLD+ Prior to LC-MS/MS Analysis Application Note AN842.V. Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE PLD+ Prior to LC-MS/MS Analysis Page Extraction of 25-hydroxy Vitamin D from Serum Using ISOLUTE PLD+ Prior to LC-MS/MS

More information

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS

A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS A Novel Solution for Vitamin K₁ and K₂ Analysis in Human Plasma by LC-MS/MS By Shun-Hsin Liang and Frances Carroll Abstract Vitamin K₁ and K₂ analysis is typically complex and time-consuming because these

More information

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid

Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Vitamin D Metabolite Analysis in Biological Samples Using Agilent Captiva EMR Lipid Application Note Clinical Research Authors Derick Lucas and Limian Zhao Agilent Technologies, Inc. Abstract Lipids from

More information

LC-MS/MS quantitative analysis of Polyunsaturated Omega 3, 6,7 and 9 Fatty Acids in Serum for

LC-MS/MS quantitative analysis of Polyunsaturated Omega 3, 6,7 and 9 Fatty Acids in Serum for POSTER NOTE 64921 LC-MS/MS quantitative analysis of Polyunsaturated Omega 3, 6,7 and 9 Fatty Acids in Serum for Research Use LC-MS/MS quantitative analysis of Poly Rory M Doyle*, Thermo Scientific, Inc,

More information

Detection of Cotinine and 3- hydroxycotine in Smokers Urine

Detection of Cotinine and 3- hydroxycotine in Smokers Urine Detection of Cotinine and 3- hydroxycotine in Smokers Urine Behavioural and Situational Research Group School of Medicine, University of Tasmania Version number: 2 Effective date: 01/12/2015 Review due:

More information

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis

Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis Application Note AN782 Extraction of Multiple Mycotoxins from Grain Using ISOLUTE Myco Page 1 Extraction of Multiple Mycotoxins From Grain Using ISOLUTE Myco prior to LC-MS/MS Analysis This application

More information

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis

Extraction of Aflatoxin M1 From Infant Formula Using ISOLUTE Myco SPE Columns prior to LC-MS/MS Analysis Application Note AN807 Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco Page Extraction of Aflatoxin M From Infant Formula Using ISLUTE Myco SPE Columns prior to LC-MS/MS Analysis This application

More information

Automated Hydrolysis, Extraction and Determination of Opioids in Urine using a Novel Robotic Autosampler and LC-MS/MS Platform

Automated Hydrolysis, Extraction and Determination of Opioids in Urine using a Novel Robotic Autosampler and LC-MS/MS Platform Automated Hydrolysis, Extraction and Determination of Opioids in Urine using a Novel Robotic Autosampler and LC-MS/MS Platform Fredrick D. Foster, John R. Stuff, Jacqueline Whitecavage GERSTEL, Inc., 701

More information

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system

Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Fast and simultaneous analysis of ethanol metabolites and barbiturates using the QTRAP 4500 LC-MS/MS system Xiang He 1, Adrian Taylor 2 and Alexandre Wang 1 1 SCIEX, Redwood City, USA. 2 SCIEX, Concord,

More information

Supporting Information

Supporting Information Supporting Information Schlosburg et al. 10.1073/pnas.1219159110 SI Materials and Methods: Quantification of Heroin Metabolites Sample Collection. Trunk blood was collected in a 1:1 ratio with acetate

More information

Application Note. Author. Abstract. Introduction. Food Safety

Application Note. Author. Abstract. Introduction. Food Safety Determination of β2-agonists in Pork with SPE eanup and LC-MS/MS Detection Using Agilent BondElut PCX Solid-Phase Extraction Cartridges, Agilent Poroshell 120 column and Liquid Chromatography-Tandem Mass

More information

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research

UPLC-MS/MS Analysis of Azole Antifungals in Serum for Clinical Research Stephen Balloch and Gareth Hammond Waters Corporation, Wilmslow, UK APPLICATION BENEFITS Analytical selectivity afforded by mass selective detection Wide linear measuring range Simple, inexpensive sample

More information

Paul D. Rainville Ph.D. Health Sciences Group Waters Corporation Waters Corporation 1

Paul D. Rainville Ph.D. Health Sciences Group Waters Corporation Waters Corporation 1 A new level of sensitivity and standardization: The promise of integrated micro fluidic devices coupled with mass spectrometry for the analysis of biofluids Paul D. Rainville Ph.D. Health Sciences Group

More information

Modernizing the Forensic Lab with LC-MS/MS Technology

Modernizing the Forensic Lab with LC-MS/MS Technology Modernizing the Lab with LC-MS/MS Technology Innovative SCIEX Analytical Tools for the Rapid Identification of Drugs of Abuse in Samples Oscar G. Cabrices 1, Holly McCall 1, Xiang He 1, Alexandre Wang

More information

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS

Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS Comprehensive Forensic Toxicology Screening in Serum using On-Line SPE LC-MS/MS SCIEX QTRAP 4500 LC-MS/MS System and Spark Holland PICO Adrian M. Taylor 1, Peter Ringeling 2, Martin Sibum 2, Stefan Sturm

More information

Sample Concentration and Analysis of Human Hormones in Drinking Water

Sample Concentration and Analysis of Human Hormones in Drinking Water Sample Concentration and Analysis of Human Hormones in Drinking Water Carl Fisher Applications Chemist Ion Chromatography/Sample Preparation Thermo Fisher Scientific March 1, 215 1 The world leader in

More information

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer

Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer Application Note LCMS-108 Quantitation of benzodiazepines and Z-drugs in serum with the EVOQ TM LC triple quadrupole mass spectrometer Abstract This study demonstrates a sensitive, rapid and reliable research

More information

Screening by immunoassay and confirmation & quantitation by GC-MS of buprenorphine and norbuprenorphine in urine, whole blood and serum

Screening by immunoassay and confirmation & quantitation by GC-MS of buprenorphine and norbuprenorphine in urine, whole blood and serum Screening by immunoassay and confirmation & quantitation by GC-MS of buprenorphine and norbuprenorphine in urine, whole blood and serum NINA KANGAS, SIRPA MYKKÄNEN, SANNA KYLLÖNEN, PÄIVI RAJALA, KARI ARINIEMI

More information

Determination of Opiates and Metabolites in Blood Using Electrospray LC/MS. Application Note

Determination of Opiates and Metabolites in Blood Using Electrospray LC/MS. Application Note Deteration of piates and Metabolites in Blood Using Electrospray LC/MS Application Note Scott A. Schlueter and James D. Hutchison, Jr. Montana Department of Justice, Division of Forensic Science John M.

More information

Extraction of 11-nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE. SLE+ Prior to GC/MS Analysis

Extraction of 11-nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE. SLE+ Prior to GC/MS Analysis Application Note AN84 Extraction of -nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE SLE+ Page Extraction of -nor-9-carboxy-tetrahydrocannabinol from Hydrolyzed Urine by ISOLUTE SLE+

More information

Solving One of Chromatography s Biggest Dilemmas Proper Sealing of Chromatography Autosampler Vials

Solving One of Chromatography s Biggest Dilemmas Proper Sealing of Chromatography Autosampler Vials Solving One of Chromatography s Biggest Dilemmas Proper Sealing of Chromatography Autosampler Vials D. Edwards 2, D. Lennartz 1, L.Shick 2 1 Thermo Fisher Scientific, Langerwehe, Germany 2 Thermo Fisher

More information

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ

Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ Application Note Clinical Research Analysis of anti-epileptic drugs in human serum using an Agilent Ultivo LC/TQ Authors Jennifer Hitchcock 1, Lauren Frick 2, Peter Stone 1, and Vaughn Miller 2 1 Agilent

More information

Mercury Speciation Determinations in Asian Dietary Supplements

Mercury Speciation Determinations in Asian Dietary Supplements Mercury Speciation Determinations in Asian Dietary Supplements Terri Christison, Deepali Mohindra, Frank Hoefler, and Linda Lopez, Thermo Fisher Scientific, Sunnyvale, California, USA Overview Purpose:

More information

Rapid and Sensitive Analysis of a 93-Compound Forensic Panel in Urine using the QTRAP /Triple Quad 4500 LC- MS/MS System

Rapid and Sensitive Analysis of a 93-Compound Forensic Panel in Urine using the QTRAP /Triple Quad 4500 LC- MS/MS System Rapid and Sensitive Analysis of a 93-Compound Forensic Panel in Urine using the QTRAP /Triple Quad 4500 LC- MS/MS System Xiang He, 1 Casey Burrows 1, Matthew Noestheden 2, Michael Jarvis, 2 Adrian Taylor,

More information

Rapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection

Rapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection Rapid and Direct Analysis of Free Phytosterols by Reversed Phase HPLC with Electrochemical Detection Bruce Bailey, Marc Plante, David Thomas, Qi Zhang and Ian Acworth Thermo Fisher Scientific, Chelmsford,

More information

Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology

Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology Analysis of Rosuvastatin in Dried Blood Spot and Plasma Using ACQUITY UPLC with 2D Technology Claude Mallet, 1 Jennifer Simeone, 2 Paul Rainville 3 1 Workflow Integration Group, Separations Technologies,

More information

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode

Determination of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode Deteration of Clinically Relevant Compounds using HPLC and Electrochemical Detection with a Boron-Doped Diamond Electrode Bruce Bailey, Marc Plante, David Thomas, Qi Zhang and Ian Acworth Thermo Fisher

More information

Determination of Selected Illegal Drugs and its Important Metabolites in Waste Water by Large Volume Direct Injection HPLC-MS/MS

Determination of Selected Illegal Drugs and its Important Metabolites in Waste Water by Large Volume Direct Injection HPLC-MS/MS Determination of Selected Illegal Drugs and its Important Metabolites in Waste Water by Large Volume Direct Injection HPLC-MS/MS Jean-Daniel Berset 1 and André Schreiber 2 1 Water and Soil Protection Laboratory,

More information

Integrated Targeted Quantitation Method for Insulin and its Therapeutic Analogs

Integrated Targeted Quantitation Method for Insulin and its Therapeutic Analogs Integrated Targeted Quantitation Method for Insulin and its Therapeutic Analogs Eric Niederkofler, 1 Dobrin Nedelkov, 1 Urban Kiernan, 1 David Phillips, 1 Kemmons Tubbs, 1 Scott Peterman, 2 Bryan Krastins,

More information

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid

Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid Development of a Bioanalytical Method for Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid Joanne ( 乔安妮 ) Mather Senior Scientist Waters Corporation Data courtesy of Erin Chambers and Mary

More information

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages

Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages APPLICATION NOTE 21671 Rapid and sensitive UHPLC screening for water soluble vitamins in sports beverages Authors Jon Bardsley, Thermo Fisher Scientific, Runcorn, UK Keywords Vanquish Flex, Acclaim PolarAdvantage

More information

Dienes Derivatization MaxSpec Kit

Dienes Derivatization MaxSpec Kit Dienes Derivatization MaxSpec Kit Item No. 601510 www.caymanchem.com Customer Service 800.364.9897 Technical Support 888.526.5351 1180 E. Ellsworth Rd Ann Arbor, MI USA TABLE OF CONTENTS GENERAL INFORMATION

More information

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1

Dr. Erin E. Chambers Waters Corporation. Presented by Dr. Diego Rodriguez Cabaleiro Waters Europe Waters Corporation 1 Development of an SPE-LC/MS/MS Assay for the Simultaneous Quantification of Amyloid Beta Peptides in Cerebrospinal Fluid in Support of Alzheimer s Research Dr. Erin E. Chambers Waters Corporation Presented

More information

Offline and online sample extraction for the quantification of benzodiazepines in human plasma or serum for clinical research

Offline and online sample extraction for the quantification of benzodiazepines in human plasma or serum for clinical research TECHNICAL NOTE 64913 Valium (diazepam) structure Offline and online sample extraction for the quantification of benzodiazepines in human plasma or serum for clinical research Authors Claudio De Nardi,

More information

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation

Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation PO-CON69E Integration of steroids analysis in serum using LC-MS/MS with full-automated sample preparation MSACL 6 EU Stéphane Moreau, Daisuke Kawakami, Toshikazu Minohata Shimadzu Europe GmbH, Duisburg,

More information

Carl Fisher, Terri Christison, Hua Yang, Monika Verma, and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA

Carl Fisher, Terri Christison, Hua Yang, Monika Verma, and Linda Lopez Thermo Fisher Scientific, Sunnyvale, CA, USA Fast Determination of Lactose and Lactulose in Dairy Products Using a 4 μm Particle Column and High-Performance Anion-Exchange Chromatography with Carl Fisher, Terri Christison, Hua Yang, Monika Verma,

More information

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer

Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate Mass AxION 2 TOF Mass Spectrometer application Note Liquid Chromatography/ Mass Spectrometry Authors Sharanya Reddy Blas Cerda PerkinElmer, Inc. Shelton, CT USA Quantitative Analysis of Drugs of Abuse in Urine using UHPLC Coupled to Accurate

More information

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS A Comprehensive Method for the Analysis of Pain Management Drugs and Drugs of Abuse Incorporating Simplified, Rapid Mixed-Mode SPE with UPLC-MS/MS for Clinical Research Jonathan P. Danaceau, Scott Freeto,

More information

LC Application Note. Dangerous driver?

LC Application Note. Dangerous driver? LC Application Note Dangerous driver? www.palsystem.com Dangerous driver? Robert M. Sears 1 ; Kenneth C. Lewis 2 ; and Kim Gamble 3 1 SC Law Enforcement Division, Columbia, SC 29221; 2 OpAns LLC, Durham

More information

Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk

Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk Meeting Challenging Requirements for the Quantitation of Regulated Growth Promoters Dexamethasone and Betamethasone in Liver and Milk Yoann Deceuninck 1, Emmanuelle Bichon 1, Paul Silcock 2, Fabrice Monteau

More information

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS

Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS Analysis of Acrylamide in French Fries using Agilent Bond Elut QuEChERS AOAC kit and LC/MS/MS Food Application Author Fadwa Al-Taher Institute for Food Safety and Health Illinois Institute of Technology

More information

Step 3: muscle, nasal sprays and drops or used as topical

Step 3: muscle, nasal sprays and drops or used as topical Extraction of Corticosteroids using 96-well Supported Liquid Extraction (SLE) and LC-MS/MS Analysis Lee Williams, Matthew Cleeve, elen Lodder, Steve Jordan, Richard Calverley & Joanna Smith Biotage GB

More information

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column

4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column Clinical, Forensic & Toxicology Applications 4.5 Minute Analysis of Benzodiazepines in Urine and Whole Blood Using LC/MS/MS and an Ultra Biphenyl Column By Amanda Rigdon Abstract A rapid, sensitive method

More information

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition

Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Rapid Analysis of Water-Soluble Vitamins in Infant Formula by Standard-Addition Evelyn Goh Waters Pacific, Singapore APPLICATION BENEFITS This method allows for the simultaneous analysis of 12 water-soluble

More information

Fig. 1: Chemical structure of arachidonic acid COOH CH 3

Fig. 1: Chemical structure of arachidonic acid COOH CH 3 Elimination of Matrix Effects Using Mixed-mode SPE Plate for High Throughput Analysis of Free Arachidonic Acid in Plasma by LC-MS/MS Wan Wang, Suzi Qin, Linsen Li, Warren Chen, Jerry Wang 179, Southern

More information

[ APPLICATION NOTE ] UPLC-MS/MS Analysis of 45 Amino Acids Using the Kairos Amino Acid Kit for Biomedical Research INTRODUCTION APPLICATION BENEFITS

[ APPLICATION NOTE ] UPLC-MS/MS Analysis of 45 Amino Acids Using the Kairos Amino Acid Kit for Biomedical Research INTRODUCTION APPLICATION BENEFITS UPLC-MS/MS Analysis of 45 Amino Acids Using the Kairos Amino Acid Kit for Biomedical Research Padhraic Rossiter, 1 Jaime Salcedo Dominguez, 1 Jennifer Warren, 1 Norma Breen, 1 Lisa Calton 2 1 Waters Corporation,

More information

Rapid and Robust Detection of THC and Its Metabolites in Blood

Rapid and Robust Detection of THC and Its Metabolites in Blood Rapid and Robust Detection of THC and Its Metabolites in Blood Application Note Forensics/Doping Control Author Stephan Baumann Agilent Technologies, Inc. Santa Clara CA 95051 USA Abstract A robust method

More information

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions Simplifying Qual/Quan Analysis in Discovery DMPK using UPLC and Xevo TQ MS Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION The determination of the drug metabolism

More information

Analysis of drugs of abuse in biological matrix using Time of Flight technology

Analysis of drugs of abuse in biological matrix using Time of Flight technology Analysis of drugs of abuse in biological matrix using Time of Flight technology Niclas Stephanson, PhD Department of Clinical Pharmacology Karolinska University Hospital Karolinska Institutet Stockholm,

More information

Nitrogen/Protein Determination in Starch by Flash Combustion using Large Sample Weight as an Alternative to the Kjeldahl Method

Nitrogen/Protein Determination in Starch by Flash Combustion using Large Sample Weight as an Alternative to the Kjeldahl Method Nitrogen/Protein Determination in Starch by Flash Combustion using Large Sample Weight as an Alternative to the Kjeldahl Method Liliana Krotz and Guido Giazzi Thermo Fisher Scientific, Milan, Italy Overview

More information

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations

Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations Advancing your Forensic Toxicology Analyses; Adopting the Latest in Mass Spectrometry Innovations For Research Use Only. Not for use in diagnostic procedures. 1 2015 AB Sciex RUO-MKT-11-1018-A For research

More information

Analysis of Cholesterol-Lowering Drugs (Statins) Using Dried Matrix Spot Technology

Analysis of Cholesterol-Lowering Drugs (Statins) Using Dried Matrix Spot Technology Analysis of Cholesterol-Lowering Drugs (Statins) Using Dried Matrix Spot Technology Application Note Small Molecule Pharmaceuticals and Generics Authors Ritu Arora, William udson, Ben Yong, and Paul Boguszewski

More information

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis

Comprehensive Study of SLE as a Sample. Preparation Tool for Bioanalysis Comprehensive Study of SLE as a Sample Preparation Tool for Bioanalysis Wan Wang, Warren Chen, Jerry Wang Bonna-Agela Technologies 179 Southern Street, West TEDA, Tianjin, China Abstract A simple, fast,

More information

Extraction of Synthetic and Naturally Occurring Cannabinoids in Urine Using SPE and LC-MS/MS

Extraction of Synthetic and Naturally Occurring Cannabinoids in Urine Using SPE and LC-MS/MS Extraction of Synthetic and Naturally Occurring Cannabinoids in Urine Using SPE and LC-MS/MS UCT Part Numbers SSHLD063 Styre Screen HLD 60 mg, 6 ml column SPHPHO6001-5 Select ph Buffer Pouches 100 mm Phosphate

More information