Novel surfactant to generate robust micro-droplets. product datasheet. Description 2 Main benefits 3 Using Pico-Surf 2 3 Sphere Fluidics Ltd.

Size: px
Start display at page:

Download "Novel surfactant to generate robust micro-droplets. product datasheet. Description 2 Main benefits 3 Using Pico-Surf 2 3 Sphere Fluidics Ltd."

Transcription

1 Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0) F: +44 (0) E: W: Pico-Surf 2 Dolomite Microfluidics North America Office Blacktrace Inc, 29 Albion Place Charlestown, MA 02129, USA C: T: F: E: salesus@dolomite-microfluidics.com Novel surfactant to generate robust micro-droplets product datasheet page Description 2 Main benefits 3 Using Pico-Surf 2 3 Sphere Fluidics Ltd. 4 The Dolomite Centre Limited Page 1 of 5

2 Part name Part No. Pico-Surf 2, 10ml, 2% in FC Pico-Surf 2, 10ml, 5% in FC Pico-Surf 2, 50ml, 2% in FC Pico-Surf 2, 50ml, 5% in FC Pico-Surf 2, 100ml, 2% in FC Pico-Surf 2, 100ml, 5% in FC Description Micro-droplets are a fascinating area of research. They are especially important where tests need to be conducted on only a few nanolitres of sample containing, for example, cells or DNA. Micro-droplet technology enables scientists and researchers to perform thousands of simultaneous reactions on single cells and small populations of molecules contained within aqueous droplets. Pico-Surf 2 is a specialised chemical solution containing a proprietary surfactant in a fluorocarbon carrier oil. The surfactant acts as an interface stabilization agent that enables stability of the picodroplets under a wide range of temperature and biological conditions. Available in 10ml, 50ml and 100ml, the surfactant can be used together with Dolomite s Droplet Junction Chips as well as Dolomite s novel Picodroplet Formation Chip and Picodroplet Reservoir Chip when coated with Pico-Glide 1. Algae growth in picodroplets stabilized with Pico-Surf 2 Pico-Surf 2_product datasheet Page 2 of 5

3 % % The Dolomite Centre Ltd Main benefits Pico-Surf 2 is particularly suitable for cell growth studies and analysis by electrospray ionisation mass spectrometry (ESI-MS) Facilitates reliable formation and stabilization of droplets from Ø 25µm to Ø 100µm (volume range of 8pl to 500pl) No or low background signal in electrospray mass spectrometry (ESI-MS) Long shelf life High purity Using Pico-Surf 2 Droplet Storage and Incubation Users are recommended to store droplets generated with Pico-Surf 2, in sterile, plastic (micro) centrifuge tubes. However, they can also be stored in any device or container having hydrophobic surface properties. Once generated, Pico-Surf 2 emulsions are stable for up to one week when stored between 4 C to 65 C. For long-term storage, especially at elevated temperatures, topping the emulsion with mineral oil is recommended to reduce or eliminate evaporation and contamination. The following graph shows a comparison of protein analysis in samples analysed using picodroplets ESI-MS with conventional ESI-MS alpha LA droplets XL alpha lactalbumin 20 um droplet 9 53 (0.134) Cm (3:561) Picodroplet MS: M -lactalbumin in 22.5 mm NH 4 OAc % Pico-Surf 2 in HFE TOF MS ES+ 290 XL alpha lactalbumin 20 um conventional 8 (0.148) Cm (6:13) Conventional MS: M -lactalbumin in 22.5 mm NH 4 OAc TOF MS ES+ 313 m/z Pico-Surf 2_product datasheet Page 3 of 5

4 Sphere Fluidics Ltd. Sphere Fluidics Ltd is a leading company specialised in picodroplet technology that performs thousands of simultaneous analyses on single cells and small populations of molecules. Sphere Fluidics Ltd is commercialising new lab-on-a-chip and picodroplet technology developed at Cambridge University by company founder Professor Chris Abell and Professor Wilhelm Huck. Focussing on storing and retrieving individual picodroplets containing a unique sample, their technology benefits a wide range of applications, including rapid antibody discovery, identification of novel algal strains and the generation of new biocatalysts. For more information please visit Pico-Surf 2 is a trademark of Sphere Fluidics FC-40 is a trademark of 3M Company Pico-Surf 2_product datasheet Page 4 of 5

5 Pico-Surf 2_product datasheet Page 5 of 5

product datasheet Description 2 Main benefits 2 Using Pico-Break 1 for phase separation of 5 non-cell emulsions

product datasheet Description 2 Main benefits 2 Using Pico-Break 1 for phase separation of 5 non-cell emulsions Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0)1763 242491 F: +44 (0)1763 246125 E: sales@dolomite-microfluidics.com W: www.dolomite-microfluidics.com Pico-Break

More information

Membrane Chip Interface and Accessories

Membrane Chip Interface and Accessories Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0)1763 242491 F: +44 (0)1763 246125 E: sales@dolomite-microfluidics.com W: www.dolomite-microfluidics.com Dolomite

More information

Suppl. Table 1: CV of pooled lipoprotein fractions analysed by ESI-MS/MS

Suppl. Table 1: CV of pooled lipoprotein fractions analysed by ESI-MS/MS Supplement VLDL LDL HDL PC 3.3 1.77 1.3 LPC 4.82 2.5.35 SM 3.1 4.6 1.92 CER 2.17 6.3 4.15 PE 3.18 1.93 2.79 PE-pl 13.18 1.9 2.32 CE 2.9.65.4 FC.36 3.5 2.54 Suppl. Table 1: CV of pooled lipoprotein fractions

More information

DetergentOUT GBS10 Spin Plates

DetergentOUT GBS10 Spin Plates G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name DetergentOUT GBS10 Spin Plates 96-Well Plates for the Removal of Detergents from Peptide

More information

Pluricyte Cardiomyocytes. using the Multiwell MEA System from Multi Channel Systems

Pluricyte Cardiomyocytes. using the Multiwell MEA System from Multi Channel Systems Pluricyte Cardiomyocytes using the Multiwell MEA System from Multi Channel Systems User Guide Version 3.1 / March 2018 Contents 1. Introduction 2 2. Workflow 3 3. Important Recommendations 4 4. Equipment,

More information

Supplementary Figure 1. mrna targets were found in exosomes and absent in free-floating supernatant. Serum exosomes and exosome-free supernatant were

Supplementary Figure 1. mrna targets were found in exosomes and absent in free-floating supernatant. Serum exosomes and exosome-free supernatant were Supplementary Figure 1. mrna targets were found in exosomes and absent in free-floating supernatant. Serum exosomes and exosome-free supernatant were separated via ultracentrifugation and lysed to analyze

More information

Pluricyte Cardiomyocytes

Pluricyte Cardiomyocytes Pluricyte Cardiomyocytes Manual Version 2.1 / March 2018 Contents 1. Introduction 2 2. Equipment, Materials and Reagents 3 3. Methods 4 3.1 Coating of tissue culture plates 4 3.2 Thawing Pluricyte Cardiomyocytes

More information

Paul D. Rainville Ph.D. Health Sciences Group Waters Corporation Waters Corporation 1

Paul D. Rainville Ph.D. Health Sciences Group Waters Corporation Waters Corporation 1 A new level of sensitivity and standardization: The promise of integrated micro fluidic devices coupled with mass spectrometry for the analysis of biofluids Paul D. Rainville Ph.D. Health Sciences Group

More information

Neosolaniol. [Methods listed in the Feed Analysis Standards]

Neosolaniol. [Methods listed in the Feed Analysis Standards] Neosolaniol [Methods listed in the Feed Analysis Standards] 1 Simultaneous analysis of mycotoxins by liquid chromatography/ tandem mass spectrometry [Feed Analysis Standards, Chapter 5, Section 1 9.1 ]

More information

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis

A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis A New HILIC/RP Mixed-Mode Column and Its Applications in Surfactant Analysis X. Liu, C. Pohl, Dionex Corporation, Sunnyvale, CA, USA ABSTRACT Although reversed-phase (RP) silica columns (e.g., C18 and

More information

Simplifying Microfluidic Separation Devices towards Field-Detection of Blood Parasites

Simplifying Microfluidic Separation Devices towards Field-Detection of Blood Parasites Electronic Supplementary Material (ESI) for Analytical Methods. Supplementary Material (ESI) for Analytical Methods Simplifying Microfluidic Separation Devices towards Field-Detection of Blood Parasites

More information

Valve-Based Microfluidic Compression Platform: Single Axon Injury and Regrowth

Valve-Based Microfluidic Compression Platform: Single Axon Injury and Regrowth Supplementary Material (ESI) for Lab on a Chip This Journal is The Royal Society of Chemistry 2011 Valve-Based Microfluidic Compression Platform: Single Axon Injury and Regrowth Suneil Hosmane a, Adam

More information

Exploring Changes in Primary Metabolites in Alzheimer s Disease using Targeted LC-MS/MS

Exploring Changes in Primary Metabolites in Alzheimer s Disease using Targeted LC-MS/MS PO-CON1694E Exploring Changes in Primary Metabolites in Alzheimer s Disease using Targeted LC-MS/MS MSACL 216 EU Nicola Gray 1, Stuart Snowden 2, Min Kim 2, Chris Titman 1, Cristina Legido-Quigley 2 1

More information

Fuan Wu. Generation of α linolenic acid emulsion droplet from silkworm pupae oil by microchips. E mail:

Fuan Wu. Generation of α linolenic acid emulsion droplet from silkworm pupae oil by microchips. E mail: Generation of α linolenic acid emulsion droplet from silkworm pupae oil by microchips Fuan Wu School of Biotechnology, Jiangsu University of Science and Technology Sericultural Research Institute, Chinese

More information

Pur A Lyzer Midi Dialysis Kit Manual

Pur A Lyzer Midi Dialysis Kit Manual Pur A Lyzer Midi Dialysis Kit Manual Pur A Lyzer Midi Dialysis Kit Catalog Numbers PURD10005 PURD35010 PURD60010 PURD35030 PURD60030 PURD35050 PURD60050 PURD35100 PURD60100 Product Description Pur A Lyzer

More information

Formulation of Redispersible Freeze-dried Emulsions. Gladness M. Manecka

Formulation of Redispersible Freeze-dried Emulsions. Gladness M. Manecka Formulation of Redispersible Freeze-dried Emulsions Gladness M. Manecka 1 Introduction Stabilisation Destabilisation Oil Water Coalescence Flocculation Emulsifier + Homogenisation 2 Oil-in-water emulsion

More information

ab Nuclear Extract Kit

ab Nuclear Extract Kit Version 1 Last updated 10 November 2017 ab221978 Nuclear Extract Kit For the preparation of nuclear extracts from mammalian and tissue. This product is for research use only and is not intended for diagnostic

More information

ABIOpure TM Viral (version 2.0)

ABIOpure TM Viral (version 2.0) ABIOpure TM Viral (version 2.0) DNA/RNA Extraction Handbook Cat No: M561VT50 FOR RESEARCH USE ONLY Table of Contents Contents Page Kit Components 3 Precautions 3 Stability & Storage 4 General Description

More information

An Alternative Approach: Top-Down Bioanalysis of Intact Large Molecules Can this be part of the future? Lecture 8, Page 27

An Alternative Approach: Top-Down Bioanalysis of Intact Large Molecules Can this be part of the future? Lecture 8, Page 27 An Alternative Approach: Top-Down Bioanalysis of Intact Large Molecules Can this be part of the future? Lecture 8, Page 27 Top-down HRAM Bioanalysis of Native Proteins/Molecules Relative Abundance 100

More information

Pur A Lyzer Mega Dialysis Kit Manual

Pur A Lyzer Mega Dialysis Kit Manual Pur A Lyzer Mega Dialysis Kit Manual Pur A Lyzer Mega Dialysis Kit Catalog Numbers PURG10010 PURG10015 PURG10020 PURG12010 PURG12015 PURG12020 PURG35010 PURG35015 PURG35020 PURG60010 PURG60015 PURG60020

More information

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS

[ APPLICATION NOTE ] APPLICATION BENEFITS INTRODUCTION WATERS SOLUTIONS KEYWORDS [ APPLICATI TE ] Ion Mobility-enabled Data-dependent Experiments Distinguishing Co-eluting Isomeric Metabolites Using an IMS-QTof Mass Spectrometer Jayne Kirk, 1 Russell Mortishire Smith, 1 Robert Beecher,

More information

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions

O O H. Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION EXPERIMENTAL. LC /MS conditions Simplifying Qual/Quan Analysis in Discovery DMPK using UPLC and Xevo TQ MS Robert S. Plumb and Paul D. Rainville Waters Corporation, Milford, MA, U.S. INTRODUCTION The determination of the drug metabolism

More information

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS

LC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS LC/MS/MS SOLUTIONS FOR LIPIDOMICS Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS Lipids play a key role in many biological processes, such as the formation of cell membranes and signaling

More information

OzScientific Pty Ltd. Knowledge-driven Solutions for Dairy & Food Industries

OzScientific Pty Ltd. Knowledge-driven Solutions for Dairy & Food Industries OzScientific Pty Ltd Knowledge-driven Solutions for Dairy & Food Industries About Us R&D organisation delivering knowledge-driven solutions to the dairy and food industries worldwide. Based at Hoppers

More information

SUPPORTING INFORMATION:

SUPPORTING INFORMATION: 1S SUPPORTING INFORMATION: The discovery of the once weekly glucagon like peptide 1 (GLP-1) analog semaglutide Jesper Lau*, Paw Bloch, Lauge Schäffer, Ingrid Pettersson, Jane Spetzler, Jacob Kofoed, Kjeld

More information

PosterREPRINT EVALUATION OF A RF-ONLY STACKED RING BASED COLLISION CELL WITH AXIAL FIELD FOR THE LC-MS-MS ANALYSIS OF THE METABOLITES OF RABEPRAZOLE

PosterREPRINT EVALUATION OF A RF-ONLY STACKED RING BASED COLLISION CELL WITH AXIAL FIELD FOR THE LC-MS-MS ANALYSIS OF THE METABOLITES OF RABEPRAZOLE OVERVIEW Comparison of the performance of a stacked ring based collision cell with axial field and a hexapole collision cell. Full scan LC-MS/MS-MS using precursor, product and neutral loss modes of operation

More information

Sputum DNA Collection, Preservation and Isolation Kit 50 Individual Devices

Sputum DNA Collection, Preservation and Isolation Kit 50 Individual Devices 3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: techsupport@norgenbiotek.com Sputum DNA Collection, Preservation and Isolation Kit 50 Individual

More information

Investigating Lipids

Investigating Lipids Investigating Lipids In today s culture, there is a stigma associated with the word fat. While it is true that too much fat can lead to health problems, fats (or lipids) play very important roles in biology.

More information

human Total Cathepsin B Catalog Number: DY2176

human Total Cathepsin B Catalog Number: DY2176 human Total Cathepsin B Catalog Number: DY2176 This DuoSet ELISA Development kit contains the basic components required for the development of sandwich ELISAs to measure natural and recombinant human Total

More information

ab Lipid Extraction Kit (Chloroform-Free)

ab Lipid Extraction Kit (Chloroform-Free) ab211044 Lipid Extraction Kit (Chloroform-Free) Instructions for use: For chloroform-free lipid extraction from plasma, serum, cultured cells and tissues. View kit datasheet: www.abcam.com/ab211044 (use

More information

ab HIV-1 Protease Inhibitor Screening Kit (Fluorometric)

ab HIV-1 Protease Inhibitor Screening Kit (Fluorometric) Version 1 Last updated 2 March 2017 ab211106 HIV-1 Protease Inhibitor Screening Kit (Fluorometric) For the rapid, sensitive and accurate screening of potential HIV-1 Protease inhibitors. This product is

More information

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT PA/PH/OMCL (10) 86 2R QUALIFICATION OF EQUIPMENT ANNEX 7: QUALIFICATION OF MASS SPECTROMETERS Full document title and reference Document

More information

Assessment of pro-arrhythmic effects using Pluricyte Cardiomyocytes. on the ACEA xcelligence RTCA CardioECR

Assessment of pro-arrhythmic effects using Pluricyte Cardiomyocytes. on the ACEA xcelligence RTCA CardioECR Assessment of pro-arrhythmic effects using Pluricyte Cardiomyocytes on the ACEA xcelligence RTCA CardioECR User Guide Version 3.0 / March 2018 Contents 1. Introduction 2 2. Workflow 3 3. Important recommendations

More information

Matrix-induced Signal Enhancement of Propamocarb in LC-MS/MS

Matrix-induced Signal Enhancement of Propamocarb in LC-MS/MS Observations concerning a compound a matrix a method other Matrix-induced Signal Enhancement of Propamocarb in LC-MS/MS Reported by: EURL-SRM Version 1 (last update: 24.10.2012) Brief description of problem/observation/solution:

More information

ExiPrep TM Viral DNA/ RNA Kit

ExiPrep TM Viral DNA/ RNA Kit Ver. 2.0 ExiPrep TM Viral DNA Kit (K-3515) ExiPrep TM Viral RNA Kit (K-3525) (K-3535) Safety Warnings and Precautions is developed and sold for research purposes only. It is not recommended for human or

More information

Introduction to LC/MS/MS

Introduction to LC/MS/MS Trends in 2006 Introduction to LC/MS/MS By Crystal Holt, LC/MS Product Specialist, Varian Inc. Toxicology laboratories Increased use of LC/MS Excellent LD Cheaper (still expensive) Much more robust Solves

More information

Fundamentals of Soft Ionization and MS Instrumentation

Fundamentals of Soft Ionization and MS Instrumentation Fundamentals of Soft Ionization and MS Instrumentation Ana Varela Coelho varela@itqb.unl.pt Mass Spectrometry Lab Analytical Services Unit Index Mass spectrometers and its components Ionization methods:

More information

Identification of Ginsenosides Using the SCIEX X500R QTOF System

Identification of Ginsenosides Using the SCIEX X500R QTOF System Identification of Ginsenosides Using the SCIEX X500R QTOF System Wang Sha, Cheng Haiyan, Liu Ting, Li Lijun, Jin Wenhai[Author] SCIEX, Pacific Applications Support Center (Beijing). China Background Ginseng

More information

3D Tissue Models. Simple, Low Cost Fabrication. Simple, Robust Protocols

3D Tissue Models. Simple, Low Cost Fabrication. Simple, Robust Protocols 3D Tissue Models SynVivo is a physiological, cell-based microfluidic platform that provides a morphologically and physiologically realistic microenvironment allowing real-time study of cellular behavior,

More information

ab HRV 3C Protease Inhibitor Screening Kit (Colorimetric)

ab HRV 3C Protease Inhibitor Screening Kit (Colorimetric) Version 2 Last updated 2 March 2017 ab211089 HRV 3C Protease Inhibitor Screening Kit (Colorimetric) For the rapid, sensitive and accurate screening of potential HRV 3C Protease inhibitors. This product

More information

axion Protocol Cell Culture on Microelectrode Arrays Cell Type: Cryopreserved Human ipsc-derived Neurons BioSystems v. 1.1

axion Protocol Cell Culture on Microelectrode Arrays Cell Type: Cryopreserved Human ipsc-derived Neurons BioSystems v. 1.1 axion BioSystems Cell Culture on Microelectrode Arrays Cell Type: Cryopreserved Human ipsc-derived Neurons Protocol v. 1.1 Trademarks Axion BioSystems, Inc. and the logo are trademarks of Axion BioSystems,

More information

DetergentOUT Tween. DetergentOUT GBS10. OrgoSol DetergentOUT

DetergentOUT Tween. DetergentOUT GBS10. OrgoSol DetergentOUT 252PR 01 G-Biosciences, St Louis, MO. USA 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name DetergentOUT Detergent Removal Systems For the Removal of Detergents

More information

B. semisolid materials consisting of hydrophilic and hydrophobic portions

B. semisolid materials consisting of hydrophilic and hydrophobic portions CHEM 470 Understanding Emulsions I. Definitions A. Any heterogeneous system which has at least one immiscible or barely miscible liquid dispersed in another liquid in the form of tiny droplets. A. Becher,

More information

DetergentOUT Detergent Removal Systems

DetergentOUT Detergent Removal Systems 252PR-04 G-Biosciences 1-800-628-7730 1-314-991-6034 technical@gbiosciences.com A Geno Technology, Inc. (USA) brand name DetergentOUT Detergent Removal Systems For the Removal of Detergents from Peptide

More information

Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: Fax:

Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: Fax: Bioneer Corporation 8-11,Munpyeongseo-ro, Daedeok-gu, Daejeon 34302, Republic of Korea Tel: +82-42-930-8777 Fax: +82-42-930-8688 Email: sales@bioneer.co.kr www.bioneer.co.kr Safety Warnings and Precautions

More information

SPG Membrane Emulsification

SPG Membrane Emulsification SPG Membrane Emulsification SPG Technology Co., Ltd. http://www.spg-techno.co.jp/ The characteristics of SPG membrane emulsification is shown in the diagram below compared with emulsification by a high

More information

Analysis of HMF by HPLC

Analysis of HMF by HPLC COST Action 927 Training School Building Skills on the Analysis of Thermal Process Contaminants in Foods 22-26 October 2007, Ankara Analysis of HMF by HPLC Vural Gökmen O O OH Background O COOH O R 2 Carbonyl

More information

Oil bodies as a source of naturally preemulsified oil: novel methodologies for extraction and stabilization.

Oil bodies as a source of naturally preemulsified oil: novel methodologies for extraction and stabilization. Oil bodies as a source of naturally preemulsified oil: novel methodologies for extraction and stabilization. Simone De Chirico, Vincenzo di Bari, David Gray 1 Oil body structure and composition 1 0.5 3

More information

SEPARATION OF BRANCHED PFOS ISOMERS BY UPLC WITH MS/MS DETECTION

SEPARATION OF BRANCHED PFOS ISOMERS BY UPLC WITH MS/MS DETECTION SEPARATION OF BRANCHED PFOS ISOMERS BY UPLC WITH MS/MS DETECTION Marian Twohig 1, Nicholas Ellor 1, Keith Worrall 2, Tim Jenkins 2, Gordon Kearney 2 1 Waters Corporation, 1 Cummings Center, Beverly, MA

More information

AmoyDx TM BRAF V600E Mutation Detection Kit

AmoyDx TM BRAF V600E Mutation Detection Kit AmoyDx TM BRAF V600E Mutation Detection Kit Detection of V600E mutation in the BRAF oncogene Instructions For Use Instructions Version: B3.1 Date of Revision: April 2012 Store at -20±2 o C 1/5 Background

More information

Enhanced delivery methods for greater efficacy

Enhanced delivery methods for greater efficacy On-Line Formulation Training - Anywhere In The World - Enhanced delivery methods for greater efficacy Belinda Carli Director, Institute of Personal Care Science Image showing absorbance in the outer stratum

More information

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Cell Culture (CD63 / CD81)

ab Exosome Isolation and Analysis Kit - Flow Cytometry, Cell Culture (CD63 / CD81) Version 1 Last updated 26 September 2018 ab239682 Exosome Isolation and Analysis Kit - Flow Cytometry, Cell Culture (CD63 / For the isolation and analysis of exosome from cell culture. This product is

More information

FROM GAMETES TO BLASTOCYSTS. Simpler Processes, Less Stress, Better Results.

FROM GAMETES TO BLASTOCYSTS. Simpler Processes, Less Stress, Better Results. FROM GAMETES TO BLASTOCYSTS Simpler Processes, Less Stress, Better Results. HELP AT EVERY STEP with simpler processes, less stress and better results Multipurpose Handling Medium RETRIEVE AND RINSE OOCYTES

More information

Challenges in Rapid Evaporative Ionization of Breast Tissue: a Novel Method for Realtime MS Guided Margin Control During Breast Surgery

Challenges in Rapid Evaporative Ionization of Breast Tissue: a Novel Method for Realtime MS Guided Margin Control During Breast Surgery Challenges in Rapid Evaporative Ionization of Breast Tissue: a Novel Method for Realtime MS Guided Margin Control During Breast Surgery Julia Balog 1, Emrys A. Jones 1, Edward R. St. John 2, Laura J. Muirhead

More information

Cell Migration and Invasion Assays INCUCYTE LIVE-CELL ANALYSIS SYSTEM. Real-time automated measurements of cell motility inside your incubator

Cell Migration and Invasion Assays INCUCYTE LIVE-CELL ANALYSIS SYSTEM. Real-time automated measurements of cell motility inside your incubator Cell Migration and Invasion Assays INCUCYTE LIVE-CELL ANALYSIS SYSTEM Real-time automated measurements of cell motility inside your incubator See the whole story Real-time cell motility visualization and

More information

MagniSort Mouse CD4 Naive T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

MagniSort Mouse CD4 Naive T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures. Page 1 of 2 MagniSort Mouse CD4 Naive T cell Enrichment Kit RUO: For Research Use Only. Not for use in diagnostic procedures. Mouse splenocytes were unsorted (left) or sorted with the MagniSort Mouse CD4

More information

innovative products. faster to market. reliably supplied.

innovative products. faster to market. reliably supplied. innovative products. faster to market. reliably supplied. consumer health E DEVELOPMENT DELIVERY SUPPLY We create unique, tailored consumer health solutions to help your brand grow. With more differentiated

More information

Development of Nutrient Delivery Systems: Ingredients & Challenges

Development of Nutrient Delivery Systems: Ingredients & Challenges Development of Nutrient Delivery Systems David Julian McClements and Hang Xiao Department of Food Science University of Massachusetts Development of Nutrient Delivery Systems: Ingredients & Challenges

More information

Biological Mass Spectrometry. April 30, 2014

Biological Mass Spectrometry. April 30, 2014 Biological Mass Spectrometry April 30, 2014 Mass Spectrometry Has become the method of choice for precise protein and nucleic acid mass determination in a very wide mass range peptide and nucleotide sequencing

More information

Pinpoint Slide RNA Isolation System II Catalog No. R1007

Pinpoint Slide RNA Isolation System II Catalog No. R1007 INSTRUCTION MANUAL Pinpoint Slide RNA Isolation System II Catalog No. R1007 Highlights Allows for the isolation of total RNA from paraffin-embedded tissue sections on glass slides Simple procedure combines

More information

SUPPLEMENTARY INFORMATION

SUPPLEMENTARY INFORMATION DOI: 10.1038/NCHEM.2419 Diversification of Self-Replicating Molecules Jan W. Sadownik, Elio Mattia, Piotr Nowak, Sijbren Otto* University of Groningen, Center for Systems Chemistry, Stratingh Institute

More information

ab Mammalian Cell Lysis Buffer 5X

ab Mammalian Cell Lysis Buffer 5X Version 2 Last updated 19 December 2018 ab179835 Mammalian Cell Lysis Buffer 5X For simple and rapid preparation of mammalian cell lysates. View kit datasheet: www.abcam.com/ab179835 (use www.abcam.cn/ab179835

More information

Metabolomic fingerprinting of serum samples by direct infusion mass spectrometry

Metabolomic fingerprinting of serum samples by direct infusion mass spectrometry Metabolomic fingerprinting of serum samples by direct infusion mass spectrometry Raúl González-Domínguez * Department of Chemistry, Faculty of Experimental Sciences. University of Huelva, Spain. * Corresponding

More information

E.Z.N.A. SQ Blood DNA Kit II. Table of Contents

E.Z.N.A. SQ Blood DNA Kit II. Table of Contents E.Z.N.A. SQ Blood DNA Kit II Table of Contents Introduction and Overview...2 Kit Contents/Storage and Stability...3 Blood Storage and DNA Yield...4 Preparing Reagents...5 100-500 μl Whole Blood Protocol...6

More information

Thyroid Stimulating Hormone (S-TSH) Thyroid Stimulating

Thyroid Stimulating Hormone (S-TSH) Thyroid Stimulating ab108659 Thyroid Stimulating Hormone (S-TSH) Human ELISA Kit Instructions for Use For the quantitative measurement of Human Thyroid Stimulating Hormone (S-TSH) concentrations in serum. This product is

More information

EASIMIP TM PATULIN Product Code: P250 / P250B

EASIMIP TM PATULIN Product Code: P250 / P250B EASIMIP TM PATULIN Product Code: P250 / P250B Molecularly imprinted polymer columns for use in conjunction with HPLC. For in vitro use only. P250B/V5/03.09.18 www.r-biopharm.com Contents Page Test Principle...

More information

The study of phospholipids in single cells using an integrated microfluidic device

The study of phospholipids in single cells using an integrated microfluidic device Supporting Information: The study of phospholipids in single cells using an integrated microfluidic device combined with matrix-assisted laser desorption/ionization mass spectrometry Weiyi Xie,, Dan Gao,

More information

Pneumocystis Carinii Real Time PCR Kit. For In Vitro Diagnostic Use Only User Manual

Pneumocystis Carinii Real Time PCR Kit. For In Vitro Diagnostic Use Only User Manual Revision No.: ZJ0003 Issue Date: Aug 7 th, 2008 Pneumocystis Carinii Real Time PCR Kit Cat. No.: QD-0082-02 For use with ABI Prism 7000/7300/7500/7900; Smart CyclerII; icycler iq 4/iQ 5; Rotor Gene 2000/3000;

More information

BIS-SILANE. Bisco Instructions for Use. 2-Part Porcelain Primer

BIS-SILANE. Bisco Instructions for Use. 2-Part Porcelain Primer Bisco 0459 BIS-SILANE 2-Part Porcelain Primer Instructions for Use IN-151R8 Rev. 7/18 BISCO, Inc. 1100 W. Irving Park Rd. Schaumburg, IL 60193 U.S.A. 1-847-534-6000 1-800-247-3368 Caution: U.S. Federal

More information

Ion Source. Mass Analyzer. Detector. intensity. mass/charge

Ion Source. Mass Analyzer. Detector. intensity. mass/charge Proteomics Informatics Overview of spectrometry (Week 2) Ion Source Analyzer Detector Peptide Fragmentation Ion Source Analyzer 1 Fragmentation Analyzer 2 Detector b y Liquid Chromatography (LC)-MS/MS

More information

EPIGENTEK. EpiQuik Global Acetyl Histone H3K27 Quantification Kit (Colorimetric) Base Catalog # P-4059 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

EPIGENTEK. EpiQuik Global Acetyl Histone H3K27 Quantification Kit (Colorimetric) Base Catalog # P-4059 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE EpiQuik Global Acetyl Histone H3K27 Quantification Kit (Colorimetric) Base Catalog # P-4059 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE The EpiQuik Global Acetyl Histone H3K27 Quantification Kit (Colorimetric)

More information

SCIEX Vitamin D 200M Assay for the Topaz System

SCIEX Vitamin D 200M Assay for the Topaz System The First FDA-Cleared LC-MS/MS Assay for Vitamin D SCIEX Vitamin D 200M Assay for the Topaz System The first FDA-cleared LC-MS/MS assay for Vitamin D Vitamin D is an important building block for human

More information

Human influenza A virus subtype (H3) genesig Easy Kit for use on the genesig q reaction. Primerdesign Ltd

Human influenza A virus subtype (H3) genesig Easy Kit for use on the genesig q reaction. Primerdesign Ltd TM Primerdesign Ltd Human influenza A virus subtype (H3) genesig Easy Kit for use on the genesig q16 50 reaction For general laboratory and research use only 1 genesig Easy: at a glance guide For each

More information

Norgen s HIV Proviral DNA PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad T1000 Cycler

Norgen s HIV Proviral DNA PCR Kit was developed and validated to be used with the following PCR instruments: Qiagen Rotor-Gene Q BioRad T1000 Cycler 3430 Schmon Parkway Thorold, ON, Canada L2V 4Y6 Phone: 866-667-4362 (905) 227-8848 Fax: (905) 227-1061 Email: techsupport@norgenbiotek.com HIV Proviral DNA PCR Kit Product# 33840 Product Insert Intended

More information

EpiQuik Total Histone H3 Acetylation Detection Fast Kit (Colorimetric)

EpiQuik Total Histone H3 Acetylation Detection Fast Kit (Colorimetric) EpiQuik Total Histone H3 Acetylation Detection Fast Kit (Colorimetric) Base Catalog # PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE The EpiQuik Total Histone H3 Acetylation Detection Fast Kit (Colorimetric)

More information

EPIGENTEK. EpiQuik Total Histone Extraction Kit. Base Catalog # OP-0006 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

EPIGENTEK. EpiQuik Total Histone Extraction Kit. Base Catalog # OP-0006 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE EpiQuik Total Histone Extraction Kit Base Catalog # PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE Uses: The EpiQuik Total Histone Extraction Kit is suitable for a quick preparation of total histone extracts

More information

ab Oil Red O (Lipid Stain)

ab Oil Red O (Lipid Stain) Version 2 Last updated 19 December 2018 ab150678 Oil Red O (Lipid Stain) For the histological visualization of fat cells and neutral fat. View kit datasheet: www.abcam.com/ab150678 (use www.abcam.cn/ab150678

More information

Product Use HPSC-CC are for research use only. It is not approved for human or animal use, or for application in in vitro diagnostic procedures.

Product Use HPSC-CC are for research use only. It is not approved for human or animal use, or for application in in vitro diagnostic procedures. HPSC-derived Cardiomyocyte Cells (HPSC-CC) Catalog #6240 Cell Specification Human primary cardiomyocytes and cardiac tissue are superior modeling systems for heart disease studies, drug discovery and toxicity

More information

MagniSort Mouse CD4 T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures.

MagniSort Mouse CD4 T cell Enrichment Kit Catalog Number: RUO: For Research Use Only. Not for use in diagnostic procedures. Page 1 of 2 MagniSort Mouse CD4 T cell Enrichment Kit RUO: For Research Use Only. Not for use in diagnostic procedures. Mouse splenocytes were unsorted (left) or sorted with the MagniSort Mouse CD4 T cell

More information

CESI-MS of Intact Proteins

CESI-MS of Intact Proteins CESI-MS of Intact Proteins Rob Haselberg, Chitra K. Ratnayake, Gerhardus J. de Jong, Govert W. Somsen. iomolecular nalysis, Utrecht University, Universiteitsweg 99, 58 CG, The Netherlands. eckman Coulter,

More information

Rapid Screening and Quantitation of Postharvest Fungicides on Citrus Fruits Using AxION DSA/TOF and Flexar SQ MS

Rapid Screening and Quantitation of Postharvest Fungicides on Citrus Fruits Using AxION DSA/TOF and Flexar SQ MS APPLICATION NOTE Mass Spectrometry Author: Avinash Dalmia PerkinElmer, Inc. Shelton, CT USA Rapid Screening and Quantitation of Postharvest Fungicides on Citrus Fruits Using AxION DSA/TOF and Flexar SQ

More information

Thermo Scientific ART Pipette Tips

Thermo Scientific ART Pipette Tips LIQUID HANDLING Thermo Scientific ART Pipette Tips Now offering a broad selection of barrier, non-filter and specialty tips to fit virtually any pipette in your lab, Thermo Scientific ART pipette tips

More information

INTRODUCTION TO MALDI IMAGING

INTRODUCTION TO MALDI IMAGING INTRODUCTION TO MALDI IMAGING Marten F. Snel, Emmanuelle Claude, Thérèse McKenna, and James I. Langridge Waters Corporation, Manchester, UK INT RODUCTION The last few years have seen a rapid increase in

More information

MEGA Assay. Modernizing quality control in IVF.

MEGA Assay. Modernizing quality control in IVF. MEGA Assay Modernizing quality control in IVF MEGA assures product consistency through: Analysis of pre-implantation embryo development and health by gene expression in addition to morphology Increased

More information

AquaPreserve DNA/RNA/Protein Order # Preservation and Extraction Kit 8001MT, 8060MT

AquaPreserve DNA/RNA/Protein Order # Preservation and Extraction Kit 8001MT, 8060MT AquaPreserve DNA/RNA/Protein Order # Preservation and Extraction Kit 8001MT, 8060MT MoBiTec GmbH 2014 Page 2 Contents 1. Description... 3 2. Kit Contents... 3 3. Terms & Conditions... 3 4. AquaPreserve

More information

EPIGENTEK. EpiQuik Global Histone H4 Acetylation Assay Kit. Base Catalog # P-4009 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

EPIGENTEK. EpiQuik Global Histone H4 Acetylation Assay Kit. Base Catalog # P-4009 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE EpiQuik Global Histone H4 Acetylation Assay Kit Base Catalog # PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE The EpiQuik Global Histone H4 Acetylation Assay Kit is suitable for specifically measuring global

More information

Emulsifiers for Metalworking Fluids

Emulsifiers for Metalworking Fluids Emulsifiers for Metalworking Fluids Emulsifiers from Renewable Resources Caring about nature In water miscible metalworking fluid formulations, emulsifiers constitute one of the most essential components.

More information

GUIDANCE NOTE. Application of MEMS Ultrasonic Transducers to Flow Measurement.

GUIDANCE NOTE. Application of MEMS Ultrasonic Transducers to Flow Measurement. GUIDANCE NOTE Application of MEMS Ultrasonic Transducers www.tuvnel.com Application of MEMS Ultrasonic Transducers Introduction This Guidance Note provides a review of the key issues associated with the

More information

Using CART to Mine SELDI ProteinChip Data for Biomarkers and Disease Stratification

Using CART to Mine SELDI ProteinChip Data for Biomarkers and Disease Stratification Using CART to Mine SELDI ProteinChip Data for Biomarkers and Disease Stratification Kenna Mawk, D.V.M. Informatics Product Manager Ciphergen Biosystems, Inc. Outline Introduction to ProteinChip Technology

More information

EPIGENTEK. EpiQuik Global Histone H3 Acetylation Assay Kit. Base Catalog # P-4008 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

EPIGENTEK. EpiQuik Global Histone H3 Acetylation Assay Kit. Base Catalog # P-4008 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE EpiQuik Global Histone H3 Acetylation Assay Kit Base Catalog # PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE The EpiQuik Global Histone H3 Acetylation Assay Kit is suitable for specifically measuring global

More information

Maintaining and Increasing Corn Oil Value. Joe Riley

Maintaining and Increasing Corn Oil Value. Joe Riley Maintaining and Increasing Corn Oil Value Joe Riley jriley@fecsolutions.com Why Am I Talking To You Today Update on the state of corn oil as a product Where the markets are going How to hold onto your

More information

Summary Chapter 8 CHAPTER 8. Summary. Page 173

Summary Chapter 8 CHAPTER 8. Summary. Page 173 CHAPTER 8 Summary Page 173 Chapter 2: Liquid Chromatography/Tandem Mass Spectrometry Method for Quantitative Estimation of PEG 400 and its Applications A rapid sensitive and selective MRM based method

More information

PosterREPRINT A NOVEL APPROACH TO MALDI-TOF-MS SAMPLE PREPARATION. Presented at ABRF 2002, Austin, Texas, USA, 9th - 12th March 2002.

PosterREPRINT A NOVEL APPROACH TO MALDI-TOF-MS SAMPLE PREPARATION. Presented at ABRF 2002, Austin, Texas, USA, 9th - 12th March 2002. Introduction A NOVEL APPROACH TO MALDI-TOF-MS SAMPLE PREPARATION Ed Bouvier 2, Jeff Brown 1, Emmanuelle Claude 1, John L. Gebler 2, Weibin Chen 2, *Dominic Gostick 1, Kevin Howes 1, James Langridge 1,

More information

A self-tapping internal hex. implant by MAKE IT SIMPLE

A self-tapping internal hex. implant by MAKE IT SIMPLE A self-tapping internal hex. implant by MAKE IT SIMPLE P. 4-5 P. 6-7 P. 8 P. 9 P.10 P.11 P.12 P.13 P.14 P.15 P.16-17 P. 18-19 P. 20-21 P. 22 P. 23 P. 24-25 MIS Warranty: MIS exercises great care and effort

More information

ExiPrep Plus Viral DNA/RNA Kit User s Guide ExiPrep Plus Viral DNA/RNA Kit ExiPrep Plus Viral DNA Kit ExiPrep Plus Viral RNA Kit

ExiPrep Plus Viral DNA/RNA Kit User s Guide ExiPrep Plus Viral DNA/RNA Kit ExiPrep Plus Viral DNA Kit ExiPrep Plus Viral RNA Kit User s Guide ExiPrep Plus Viral DNA/RNA Kit ExiPrep Plus Viral DNA Kit ExiPrep Plus Viral RNA Kit K-4271 K-4272 K-4273 ExiPrep Plus Viral DNA/RNA Kit (K-4271) ExiPrep Plus Viral DNA Kit (K-4272) ExiPrep

More information

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION

Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection INTRODUCTION Probing for Packaging Migrants in a Pharmaceutical Impurities Assay Using UHPLC with UV and Mass Detection Michael Jones Waters Corporation, Wilmslow, UK APPLICATION BENEFITS The ACQUITY Arc System is

More information

LABORATORY MANUAL PHM 2143 PHYSICAL PHARMACY II

LABORATORY MANUAL PHM 2143 PHYSICAL PHARMACY II DEPARTMENT OF PHARMACEUTICAL TECHNOLOGY LABORATORY MANUAL PHM 2143 PHYSICAL PHARMACY II NAME MATRIC NO. Please read the instructions, carry out the lab practical and answer the questions. You may be requested

More information