Hydrolysis Unit B-411 / E-416 Technical data sheet

Size: px
Start display at page:

Download "Hydrolysis Unit B-411 / E-416 Technical data sheet"

Transcription

1 Hydrolysis Unit B-4 / E-46 Technical data sheet The Hydrolysis Unit B-4 and E-46 ensure safe and fast acid hydrolysis for total fat content determination handling four or six samples simultaneously. The method complies with the standardized methods (Weibull Stoldt, AOAC). The B-4 (4 position) works with the B-8 extraction unit while the E-46 (6 position) is compatible with the E-86 extraction unit. POWER PREHEATING OFF HYDROLYSIS HEATING BÜCHI Hydrolysis Unit E-46

2 Scope of delivery All models are delivered ready to use and are packaged with: Components E-46 B-4 Sample tubes 8 4 Sample aspiration tubes 6 4 Rubber coupling, EPDM 6 4 Rubber coupling, Viton 4 Suction tube for E-46 Suction tube for B-4 Cap for rinsing sample tube 6 4 Stoppers, blind plug 8 4 Bottle of.5 kg quartz sand Order code Choose the configuration according to your needs: Hydrolysis Unit E-46: Supply voltage 0 0 V ±0 % 50/60 Hz 0V ±0 % 50/60 Hz Hydrolysis Unit E-46: Sealing modification 8 0 V ±0 % 50/60 Hz / Viton Hydrolysis Unit B-4: Supply voltage, sealing material V ±0 % 50/60 Hz, EPDM V ±0 % 50/60 Hz, EPDM 6 0 V ±0 % 50/60 Hz, Viton Dimensions and weight Dimensions (WxHxD) Weight E x 600 x 570 mm 4.5 kg B-4 75 x 600 x 570 mm.5 kg

3 Technical data B-4 E-46 Volume of glass sample tubes 0 ml 5 ml Height of glass sample tubes 7 ml 05 ml Volume of sample tubes Maximum sample weight Recommended particle size of quartz sand 00 ml 0g mm Recommended diatomaceous earth Celite 55 Recommended concentration of hydrochloric acid 4 mol/l Mains voltage 0 V ± 0 % or 0 V ± 0 % Frequency Power consumption Overvoltage category 50/60 Hz 00W II Pollution degree Ambient conditions For indoor use only, altitude up to 000 m above sea level, maximum relative humidity 80 % for temperatures up to 0 C, ambient temperature 0-40 C Accessories Glass parts Qty Order number Picture Sample tubes Glass sample tubes with frit for B Glass sample tubes with frit for E-8/ Glass sample tubes with frit for E-8/ Suction tube for B Suction tube for E Sample aspiration tube Additional parts Qty Order number Picture Rubber coupling, EPMD Rubber coupling, Viton Rubber coupling, Viton

4 Additional parts Qty Order number Picture Stoppers ø 45 mm, blind plug Cap for sample tube Upper insulation plate B Upper insulation plate E Pair of glass tongs 0004 Holder for sample tubes (6 pos.) 0409 Holder for sample tubes ( pos.) 0404 Holder for glass sample tubes, PTFE, microwavable (6 pos.) 0590 Holder for glass sample tubes, PP (4 pos.) 0746 Water jet pump, plastic 09 Vacuum hose Ø 0/ Quartz sand,.5 kg Special sand to be used for extraction and hydrolysis, fat free, fire dried, mm Quartz sand, 5 kg Special sand to be used for extraction and hydrolysis, fat free, fire dried, mm IQ/OQ package for B-4/E Repeating OQ for B-4/E Accessories pictures

5 Functional principle For the Weibull-Stoldt fat determination in food and animal feed, the sample must be hydrolyzed to make the fat accessible for extraction, as solvents are not capable of breaking lipids bound as lipoproteins, liposaccharides or sterol esters. Therefore hydrolysis is used to transform these lipids into extractable forms, allowing reproducible fat determination. The sample is boiled in dilute hydrochloric acid (typically 4 mol/l) to break down proteins and high molecular weight carbohydrates into acid soluble constituents. The powerful IR-heating enables fast heat transfer to the sample vessels. The hydrolysis normally takes 0 min. Then the sample is filtered over a glass sample tube filled with sand and celite. The filter residue containing the fat is rinsed with water to become neutralized. Finally the filter residue is dried ready for extraction. The celite distributes the hydrolysate evenly in the tube, preventing any clumping and helps facilitate the extraction process. The glass sample tube is designed to be used directly in the Extraction units E-8/86 or B-8 without manual transfer of the sample. Quality in your hands B-4 E-46 Data Sheet en A / Technical data are subject to change without notice / Quality Systems ISO 900 The English version is the original language version and serves as basis for all translations into other languages.

BÜCHI Hydrolysis Unit B-411 BÜCHI Extraction System B-811

BÜCHI Hydrolysis Unit B-411 BÜCHI Extraction System B-811 BÜCHI Hydrolysis Unit B-411 BÜCHI Extraction System B-811 Fat Determination in Bakery and Dairy Products according to the Weibull-Stoldt Method 1. Summary A simple and fast procedure for fat determination

More information

TECHNICAL BULLETIN METHOD 1: DETERMINATION OF TOTAL DIETARY FIBRE

TECHNICAL BULLETIN METHOD 1: DETERMINATION OF TOTAL DIETARY FIBRE TOTAL DIETARY FIBER KIT Cat N 32 v.3210051 TECHNICAL BULLETIN METHOD 1: DETERMINATION OF TOTAL DIETARY FIBRE Introduction This procedure for the determination of total dietary fiber is based on the method

More information

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer

Measures 100 ppm to 100% water content. Precision titrant delivery system. Anti-diffusion burette tip. Built-in stirrer HI 903 Karl Fischer Volumetric Titrator Measures 100 ppm to 100% water content Precision titrant delivery system 40,000 step, piston dosing pump Accurate to 0.1% Delivers as little as 0.125 µl of titrant

More information

Nitrogen and Protein Determination in Meat Products by Accelerated Digestion with Hydrogen Peroxide and Sulfuric Acid

Nitrogen and Protein Determination in Meat Products by Accelerated Digestion with Hydrogen Peroxide and Sulfuric Acid 071/2011 SpeedDigester K-436, K-439 Kjeldahl Sampler System K-370/K-371 Nitrogen and Protein Determination in Meat Products by Accelerated Digestion with Hydrogen Peroxide and Sulfuric Acid 071/2011 SpeedDigester

More information

Autotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from

Autotitrator. Technical Information and Specifications. mpt-2. detailed specification sheets from Technical Information and Specifications detailed specification sheets from www.malvern.co.uk/autotitrator MPT-2 Autotitrator Description The MPT-2 autotitrator is an optional accessory compatible with

More information

ASE Prep CR Na+ form

ASE Prep CR Na+ form ASE Prep CR Na+ form ASE Prep CR Na+ form Product Manual Page 1 of 10 PRODUCT MANUAL for the ASE Prep CR Na+ form CATION EXCHANGE RESIN 500g (P/N 080024) Dionex Corporation 2008 Document No. 065243 Revision

More information

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL 1 2 Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...

More information

General Information. Ordering. Popular Downloads. Dimensions. Technical

General Information. Ordering. Popular Downloads. Dimensions. Technical S201M-B6 Products Low Voltage Products and Systems Modular DIN Rail Products Miniature Circuit Breakers MCBs General Information Extended Product Type: S201M-B6 Product ID: 2CDS271001R0065 EAN: 4016779549424

More information

MYOMED 632X MYOMED 632X = MYOFEEDBACK MYOMED 632X = ALSO PRESSURE FEEDBACK MYOMED 632X = ALSO ELECTROTHERAPY V = ALSO VACUUM U = ALSO ULTRASOUND

MYOMED 632X MYOMED 632X = MYOFEEDBACK MYOMED 632X = ALSO PRESSURE FEEDBACK MYOMED 632X = ALSO ELECTROTHERAPY V = ALSO VACUUM U = ALSO ULTRASOUND MYOMED 632X MYOMED 632X = MYOFEEDBACK Myofeedback involves registering the electrical muscle activity using surface electrodes or cavity electrodes. The Myomed 632X is easy to operate and ensures that

More information

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION

TABLE OF CONTENTS 1.1. WARRANTY DAMAGED SHIPMENTS SERVICE INTRODUCTION UNPACKING AND INSTALLATION TABLE OF CONTENTS EDITION 5 Section 1 - WARRANTY & SERVICE 1.1. WARRANTY 2 1.2. DAMAGED SHIPMENTS 2 1.3. SERVICE 2 Section 2 - INTRODUCTION 2.1. INTRODUCTION 3 Section 3 - GENERAL 3.1. UNPACKING AND INSTALLATION

More information

Fibertec 1023 Dietary Fibre Solutions

Fibertec 1023 Dietary Fibre Solutions Fibertec 1023 Dietary Fibre Solutions Tecator Line The Fibertec 1023 Dietary Fibre Analysis System is a semi-automated incubation and filtration system for quantitative determination of dietary fibre in

More information

S201-Z2. Miniature Circuit Breaker - S200-1P - Z - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

S201-Z2. Miniature Circuit Breaker - S200-1P - Z - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S200-1P - Z - 2 ampere General Information Extended Product Type Product ID S201-Z2 2CDS251001R0278 EAN 40167795054 Catalog Description Long Description Miniature Circuit

More information

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP

TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED P18L TYPE USER S MANUAL. from a CURRENT LOOP TEMPERATURE and HUMIDITY TRANSDUCER SUPPLIED from a CURRENT LOOP P18L TYPE USER S MANUAL Contents 1. Application... 2 2. Basic requirements, operational safety... 2 3. Installation... 2 3.1. Assembly...

More information

SONOPULS STATUS HANDSFREE ULTRASOUND MAKES A DIFFERENCE FOR PATIENT AND THERAPIST

SONOPULS STATUS HANDSFREE ULTRASOUND MAKES A DIFFERENCE FOR PATIENT AND THERAPIST HANDSFREE ULTRASOUND MAKES A DIFFERENCE FOR PATIENT AND THERAPIST The StatUS TM ultrasound treatment is the latest development in therapy and treatment comfort. StatUS TM stands for Stationary Ultra Sound.

More information

Compressor Nebulizer. Model UN-014

Compressor Nebulizer. Model UN-014 Compressor Nebulizer Model UN-014 Instruction Manual Original Manuel d instructions Traduction Manual de Instrucciones Traducción Manuale di Istruzioni Traduzione ITALIANO ESPAÑOL FRANÇAIS ENGLISH 1WMPD4003398

More information

Tropic plus ultrasonic nebulizer Consumables and Accessories

Tropic plus ultrasonic nebulizer Consumables and Accessories Tropic plus ultrasonic nebulizer Consumables and Accessories Whether for humidifying the ambient air near the patient or for nebulizing medication, the Tropic plus ultrasonic nebulizer is the right solution.

More information

Safety Data Sheet. according to Regulation (EU) No. 1907/2006. SYMPROfluid universal

Safety Data Sheet. according to Regulation (EU) No. 1907/2006. SYMPROfluid universal Page 1 of 5 1. Identification of the substance/preparation and of the company/undertaking Identification of the substance or preparation Use of the substance/preparation Special denture cleaner for use

More information

Glucose analyser GA 3

Glucose analyser GA 3 Glucose analyser GA 3 NEW The GA 3 from KABE LABORTECHNIK for a precise determination of glucose and lactate values Precise, fully automated, quick and economical the GA 3! The GA 3 represents a further

More information

S201-C2. Miniature Circuit Breaker - S200-1P - C - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

S201-C2. Miniature Circuit Breaker - S200-1P - C - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S200-1P - C - 2 ampere General Information Extended Product Type Product ID 2CDS251001R0024 EAN 40167795225 Catalog Description Long Description Miniature Circuit Breaker

More information

OTAGO LIPOSURG. Compact, powerful system for infiltration and liposuction

OTAGO LIPOSURG. Compact, powerful system for infiltration and liposuction OTAGO LIPOSURG Compact, powerful system for infiltration and liposuction The Otago LipoSurg is the first medical device which allows infiltration and Liposuction in a single compact device. FEATURES AND

More information

PROCEDURE FOR GENERATION AND TESTING OF MAINSTREAM TOBACCO HEATING SYSTEM (THS or IQOS) AEROSOL USING A LINEAR SMOKING MACHINE

PROCEDURE FOR GENERATION AND TESTING OF MAINSTREAM TOBACCO HEATING SYSTEM (THS or IQOS) AEROSOL USING A LINEAR SMOKING MACHINE PROCEDURE FOR GENERATION AND TESTING OF MAINSTREAM TOBACCO HEATING SYSTEM (THS or IQOS) AEROSOL USING A LINEAR SMOKING MACHINE 1 P age Table of contents / Table des matières 1 Introduction...3 1 Scope...3

More information

NO: 24 / 2 NC: 24 / 2 at 0.1 Hz

NO: 24 / 2 NC: 24 / 2 at 0.1 Hz PCB Relays Safety Relay with double contacts OA 621, OA 6 According to DIN EN 618-1, DIN EN 618-3 With forcibly guided contacts High switching safety because of gold plated double contacts Clearance and

More information

Liquid ring vacuum pumps single-stage

Liquid ring vacuum pumps single-stage Liquid ring vacuum pumps single-stage LOH 20103, LOH 20107 Pressure range: Suction volume flow: 150 to 1013 mbar 7 to 58 m³/h CONSTRUCTION TYPE Sterling SIHI liquid ring vacuum pumps are displacement pumps

More information

MILESTONE MILESTONE ETHOS X. Microwave Total Fat Determination in Milk and Milk Products

MILESTONE MILESTONE ETHOS X. Microwave Total Fat Determination in Milk and Milk Products MILESTONE H E L P I N G C H E M I S T S MILESTONE ETHOS X Microwave Total Fat Determination in Milk and Milk Products 02 03 ETHOS X for Total Fat Determination in Milk and Milk Products MILESTONE HELPING

More information

IODINE AFFINITY. 3. Extraction Shells: Paper, 80 x 22 mm (Note 1)

IODINE AFFINITY. 3. Extraction Shells: Paper, 80 x 22 mm (Note 1) IODIN.01-1 IODINE AFFINITY PRINCIPLE SCOPE Iodine complexes preferentially with the amylose (linear fraction) in corn starch. After defatting by solvent extraction, and drying, the sample is dispersed

More information

RLS /E-EV MX SERIES

RLS /E-EV MX SERIES RLS 300 800/E-EV MX SERIES RLS/E-EV MX series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier,

More information

RLS /E MX SERIES

RLS /E MX SERIES RLS 310 610/E MX SERIES The RLS/E-MX series of burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier,

More information

Most of the ethanol that is used as a biofuel in this country is produced from corn.

Most of the ethanol that is used as a biofuel in this country is produced from corn. Chem 251 Ethanol from Corn Most of the ethanol that is used as a biofuel in this country is produced from corn. In this experiment you will make ethanol from frozen corn kernels using a process similar

More information

ICP-OES Organics Kit Installation Instructions

ICP-OES Organics Kit Installation Instructions The ICP Organics Kit is an accessory for use with the Agilent ICP-OES instruments. It is available in two versions one for axial ICP-OES and the other for radial ICP-OES. It is used to analyze directly

More information

RLS /M MX SERIES

RLS /M MX SERIES RLS/M burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all, more flexible.

More information

RLS /M MX SERIES

RLS /M MX SERIES The RLS/M MX series of burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above

More information

S202M-K2UC. Miniature Circuit Breaker - S200MUC - 2P - K - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions.

S202M-K2UC. Miniature Circuit Breaker - S200MUC - 2P - K - 2 ampere. General Information. Ordering. Popular Downloads. Dimensions. ABB Miniature Circuit Breaker - S00MUC - P - K - ampere General Information Extended Product Type Product ID S0M-KUC CDS7061R077 EAN 4013614433146 Catalog Description Long Description Miniature Circuit

More information

3. Dimensions, weights Placement and Assembly Pressure drops Noise data Material... 14

3. Dimensions, weights Placement and Assembly Pressure drops Noise data Material... 14 These technical specifications state a row of manufactured sizes and models of smoke extraction dampers - single (further only dampers) SEDS-L. It is valid for production, designing, ordering, delivery,

More information

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF

GB Translated English of Chinese Standard: GB NATIONAL STANDARD OF Translated English of Chinese Standard: GB5009.4-2016 www.chinesestandard.net Sales@ChineseStandard.net NATIONAL STANDARD OF GB THE PEOPLE S REPUBLIC OF CHINA GB 5009.4-2016 National Food Safety Standard

More information

Miniature Circuit Breaker - S200-1P - B - 2 ampere. acc. to IEC / 400 V AC acc. to IEC V AC

Miniature Circuit Breaker - S200-1P - B - 2 ampere. acc. to IEC / 400 V AC acc. to IEC V AC ABB Miniature Circuit Breaker - S200-1P - B - 2 ampere General Information Extended Product Type S201-B2 Product ID 2CDS251001R0025 EAN 4016779612944 Catalog Description Miniature Circuit Breaker - S200-1P

More information

THE NEW 4 SERIES. Complete, easy-to-use, fast and the responsible choice!

THE NEW 4 SERIES. Complete, easy-to-use, fast and the responsible choice! THE NEW 4 SERIES Complete, easy-to-use, fast and the responsible choice! THE NEW 4 SERIES COMPLETE, EASY-TO-USE, FAST AND THE RESPONSIBLE CHOICE! Complete, easy-to-use, fast and the responsible choice!

More information

Pectins. Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016

Pectins. Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016 Residue Monograph prepared by the meeting of the Joint FAO/WHO Expert Committee on Food Additives (JECFA), 82 nd meeting 2016 Pectins This monograph was also published in: Compendium of Food Additive Specifications.

More information

Product data sheet VAPODEST 500

Product data sheet VAPODEST 500 VAPODEST 500 Standard configuration VAP 500 Multi Touch Sensitive Screen 7 Automatic addition H 3 BO 3 Automatic addition H 2 O Automatic addition NaOH / reagent Programmable reaction time Programmable

More information

UNIBOX II III & IV. Exclusive CD edition March 2006

UNIBOX II III & IV. Exclusive CD edition March 2006 Exclusive CD edition March 2006 UniBox II and III: Fibre-optic Solutions for Fixed Connections The ready-to-install splice modules for the UniBox II and III combine the advantages of the UniBox family

More information

Vacuum pumps. Vacuum pumps

Vacuum pumps. Vacuum pumps For over 50 years, PIAB has been developing a range of vacuum solutions that cover the widely varying needs of the market. We constantly strive to improve our products and adapt them to market needs by

More information

RLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES

RLS/E-EV MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES The RLS/E-EV MX series of burners covers a firing range from 350 to 2400 kw, and they have been designed for use in low or medium temperature hot water boilers, hot air or steam boilers, diathermic oil

More information

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has

More information

NO: 250 / 2 NC: 250 / 1 AC 15 6) NO: 250 / 3 NC: 250 / 2 DC 13 5) NO: 24 / 1 NC: 24 / 1 DC 13 5) at 0.1 Hz. NO: 24 / 4 NC: 24 / 4 to UL 508

NO: 250 / 2 NC: 250 / 1 AC 15 6) NO: 250 / 3 NC: 250 / 2 DC 13 5) NO: 24 / 1 NC: 24 / 1 DC 13 5) at 0.1 Hz. NO: 24 / 4 NC: 24 / 4 to UL 508 PCB relays Safety relays OA 5611, OA 5612 According to DIN EN 618-1, DIN EN 618-3 With forcibly guided contacts High switching reliability due to crown contacts Low rated power consumption High mechanical

More information

METHOD OF TEST FOR DETERMINATION OF INSOLUBLE RESIDUE OF CARBONATE AGGREGATES

METHOD OF TEST FOR DETERMINATION OF INSOLUBLE RESIDUE OF CARBONATE AGGREGATES Laboratory Testing Manual Date: 96 05 01 Page 1 of 6 METHOD OF TEST FOR DETERMINATION OF INSOLUBLE RESIDUE OF CARBONATE AGGREGATES 1. SCOPE 1.1 This method covers the determination of the percentage of

More information

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. GB Translated English of Chinese Standard: GB Translated English of Chinese Standard: GB1987-2007 www.chinesestandard.net Sales@ChineseStandard.net NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA GB ICS 67.220.20 X 41 Replacing GB 1987-1986 Food

More information

PLEASE READ THIS USER MANUAL BEFORE USE

PLEASE READ THIS USER MANUAL BEFORE USE USER MANUAL Humalog 200 units/ml KwikPen, solution for injection in a pre-filled pen insulin lispro PLEASE READ THIS USER MANUAL BEFORE USE USE ONLY IN THIS PEN, OR SEVERE OVERDOSE CAN RESULT Read the

More information

Organic Molecule Composition of Milk: Lab Investigation

Organic Molecule Composition of Milk: Lab Investigation Name: Organic Molecule Composition of Milk: Lab Investigation Introduction & Background Milk & milk products have been a major food source from earliest recorded history. Milk is a natural, nutritionally

More information

Side Channel R ing Blower

Side Channel R ing Blower Side Channel R ing Blower ------------------------------------- INSTRUCTION MNUL ------------------------------------ RB20../ 30../ 40../ 50../ 60 / 80.. SERIES CONTENT PGE 1. SFETY REQUIREMENT... 1 2.

More information

Off-line filter system

Off-line filter system Off-line filter system 15 NFT / 35 NFT RE 51431-B/03.10 Replaces: -.- English Operating instructions The data specified above only serve to describe the product. No statements concerning a certain condition

More information

Chapter 5: Analysis of water content, total solids & water activity

Chapter 5: Analysis of water content, total solids & water activity Chapter 5: Analysis of water content, total solids & water activity 1 Water is an essential constituent of many foods. It may occur as an intracellular or extracellular component in vegetable and animal

More information

with ENFit compatible connectors Enteral Syringes & Accessories PRODUCT GUIDE & ORDER CODES

with ENFit compatible connectors Enteral Syringes & Accessories PRODUCT GUIDE & ORDER CODES with ENFit compatible connectors Enteral Syringes & Accessories PRODUCT GUIDE & ORDER CODES LD31603 WHAT IS ENFit? To further reduce the risk of enteral tube feeding misconnections and improve patient

More information

HI Total Acidity Mini Titrator for Water Analysis

HI Total Acidity Mini Titrator for Water Analysis HI 84530 Total Acidity Mini Titrator for Water Analysis Piston Driven Pump with Dynamic Dosing The HI 84530 incorporates dynamic dosing to provide precison titrant delivery. Dynamic dosing adjusts the

More information

Medescan Nebuliser Med - S600A Instructions Manual

Medescan Nebuliser Med - S600A Instructions Manual Medescan Nebuliser Med - S600A Instructions Manual Please read this guidebook carefully before operating this unit Your Nebuliser is intended for use in the treatment of asthma, COPD and other respiratory

More information

ELEMENT 2/ ELEMENT XR Consumables and Parts Catalog

ELEMENT 2/ ELEMENT XR Consumables and Parts Catalog ELEMENT 2/ ELEMENT XR Consumables and Parts Catalog Revision B - 2 470 Analyze Detect Measure Control 2007 Thermo Fisher Scientific. All rights reserved. Viton is a registered trademark of DuPont Dow Elastomers.

More information

RL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw

RL/B MZ SERIES. Two Stage Light Oil Burners FIRING RATES LIGHT OIL RL 300/B MZ RL 400/B MZ. 600/ kw 1000/ kw RL/B MZ series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all, more

More information

You should wear eye protection throughout this practical. Amylase is harmful, avoid contact with eyes and skin.

You should wear eye protection throughout this practical. Amylase is harmful, avoid contact with eyes and skin. Practical 3 - The identification of biological chemicals present in solutions This practical focuses on making decisions about measurements and observations, recording and presenting data and observations,

More information

Safety Data Sheet. according to Regulation (EC) No 1907/2006 TECO. SECTION 1: Identification of the substance/mixture and of the company/undertaking

Safety Data Sheet. according to Regulation (EC) No 1907/2006 TECO. SECTION 1: Identification of the substance/mixture and of the company/undertaking Page 1 of 5 SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier 1.2. Relevant identified uses of the substance or mixture and uses advised against

More information

Instruction Manual Aerogen, Inc. Part No. AG-AL1010 Rev. C

Instruction Manual Aerogen, Inc. Part No. AG-AL1010 Rev. C Instruction Manual 2004 Aerogen, Inc. Part No. AG-AL1010 Rev. C Table of Contents Introduction... 3 System description... 4 Warnings... 5 Cautions... 5 Electromagnetic Susceptibility... 5 Symbols... 6

More information

Technical Data Sheet SONOFLOW CO.55 V1.0

Technical Data Sheet SONOFLOW CO.55 V1.0 Technical Data Sheet SONOFLOW CO.55 V1.0 The sensor series SONOFLOW CO.55 V1.0 designed as clamp-on-sensors detect the flow rate of liquids in plastic tubes of different diameters or materials within a

More information

Helping to protect you from exposure to hazardous drugs

Helping to protect you from exposure to hazardous drugs Helping to protect you from exposure to hazardous drugs Closed system solution: Texium closed male luer and SmartSite needle-free valve products What you can t see can hurt you The risks are well documented

More information

Nebulizers. Small Volume Nebulizers

Nebulizers. Small Volume Nebulizers Small Volume MICRO MIST Nebulizer The MICRO MIST small volume nebulizer is designed for performance and economy and includes the design features needed by today s respiratory care practitioners. It can

More information

Material Safety Data Sheet

Material Safety Data Sheet Page of 5 SECTION : Identification of the substance/mixture and of the company/undertaking Product identifier Product group: Standard Product Chemical characterization ( Mixture ) INCI Name: Glycerin,

More information

Membrane Chip Interface and Accessories

Membrane Chip Interface and Accessories Unit 1, Anglian Business Park, Orchard Road, Royston, Hertfordshire, SG8 5TW, UK T: +44 (0)1763 242491 F: +44 (0)1763 246125 E: sales@dolomite-microfluidics.com W: www.dolomite-microfluidics.com Dolomite

More information

Advanced in vitro exposure systems

Advanced in vitro exposure systems Advanced in vitro exposure systems VITROCELL VC 1/7 SMOKING MACHINE Features for e-cigarettes VITROCELL VC 1/7 SMOKING MACHINE Linear smoking machine with high tech features square puff profiles higher

More information

Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE

Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE Advanced in vitro exposure systems VITROCELL VC 1 SMOKING MACHINE Options for e-cigarettes VITROCELL VC 1 SMOKING MACHINE Manual smoking machine with high tech features square puff profiles higher puff

More information

Safety Data Sheet. according to Regulation (EU) No. 1907/ Identification of the substance/preparation and of the company/undertaking

Safety Data Sheet. according to Regulation (EU) No. 1907/ Identification of the substance/preparation and of the company/undertaking Print date: 12.04.2011 MSDS: Page 1 of 5 1. Identification of the substance/preparation and of the company/undertaking MSDS-ID: Company/undertaking identification Company name: Street: Place: Fahltskamp

More information

max airless Operating Manual for Dispenser Read this manual thoroughly before operating the Labmax airless!

max airless Operating Manual for Dispenser Read this manual thoroughly before operating the Labmax airless! Operating Manual for max airless Dispenser Read this manual thoroughly before operating the Labmax airless! witeg Labortechnik GmbH Am Bildacker 16 D-97866 Wertheim/Main Phone: +49 (0)9342 / 9301-0 Fax:

More information

Myomed 632: The most complete device for safe treatments Myofeedback, pressure feedback, electrotherapy and ultrasound

Myomed 632: The most complete device for safe treatments Myofeedback, pressure feedback, electrotherapy and ultrasound Myomed 632: The most complete device for safe treatments Myofeedback, pressure feedback, electrotherapy and ultrasound R A complete series of therapies in the new Myomed 632 Myomed 632 = myofeedback Myofeedback

More information

BUCHI NIR Applications Milling & Bakery Industry

BUCHI NIR Applications Milling & Bakery Industry BUCHI NIR Applications Milling & Bakery Industry You need fast and reliable information about your samples in order to make far-reaching decisions. We support you in overcoming your daily challenges, from

More information

J320, J330 and J340 PLUMBING PARTS CATALOG

J320, J330 and J340 PLUMBING PARTS CATALOG PREMIUM J0, J0 and J0 PLUMBING PARTS CATALOG PREMIUM PUMP Pump/Motor # Location (for the J0 and J0) Pump/Motor # Location (for the J0) * 9 0 * 00- HOUSING: FRONT 00-90 O-RING: FRONT HOUSING 00-9 IMPELLER:.9

More information

Geräteblatt Pallazza III PGI

Geräteblatt Pallazza III PGI Technische Dokumentation Geräteblatt Pallazza III 535.08 PGI Geräteblatt Pallazza III 535.08 PGI Geräteblatt Pelletofen Fiche technique Poêle à pellets Scheda tecnica Stufe pellet Equipment sheet Pellet

More information

J350, J360 and J370 PLUMBING PARTS CATALOG

J350, J360 and J370 PLUMBING PARTS CATALOG PREMIUM J0, J0 and J0 PLUMBING PARTS CATALOG PUMP Pump/Motor # * 0 * 00- HOUSING: FRONT 00-0 O-RING: FRONT HOUSING 00- IMPELLER:. DIA 00-0 PUMP: SEAL ASSY / VITON 00- HOUSING: REAR BRACKET 00-0 MOTOR:.HP

More information

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual

Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual Page 1 / 14 Carnitine / Acylcarnitines Dried Blood Spots LC-MS/MS Analysis Kit User Manual ZV-3051-0200-15 200 Page 2 / 14 Table of Contents 1. INTENDED USE... 3 2. SUMMARY AND EXPLANATION... 3 3. TEST

More information

SWITCHGEAR PBD. fuse bases

SWITCHGEAR PBD. fuse bases SWITCHGEAR PBD fuse bases designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links ENERGY SAFELY SWITCHED SWITCHGEAR

More information

SWITCHGEAR PBD. fuse bases

SWITCHGEAR PBD. fuse bases SWITCHGEAR PBD fuse bases designed for distribution of electricity and protection of electrical equipment against short-circuits and overloads with industrial fuse links ENERGY SAFELY SWITCHED SWITCHGEAR

More information

INSTRUCTIONS FOR CLEANING, DISINFECTION AND STERILIZATION OF DFS INSTRUMENTS

INSTRUCTIONS FOR CLEANING, DISINFECTION AND STERILIZATION OF DFS INSTRUMENTS Preparation (cleaning, disinfection and sterilization) of reusable rotating dental instruments General principles All instruments must be cleaned, disinfected and sterilized before each use; this applies

More information

SpeedDigester K-436, K-439 Kjeldahl Sampler System K-370/K-371 Nitrogen and Protein Determination in Milk according to the micro-kjeldahl Method

SpeedDigester K-436, K-439 Kjeldahl Sampler System K-370/K-371 Nitrogen and Protein Determination in Milk according to the micro-kjeldahl Method SpeedDigester K-436, K-439 Kjeldahl Sampler System K-370/K-371 Nitrogen and Protein Determination in Milk according to the micro-kjeldahl Method 031/2010 031/2010 SpeedDigester K-436 / K-439 Kjeldahl Sampler

More information

The Cannabis Workflow and the IMPORTANCE OF TEMPERATURE CONTROL

The Cannabis Workflow and the IMPORTANCE OF TEMPERATURE CONTROL WHITEPAPER The Cannabis Workflow and the IMPORTANCE OF TEMPERATURE CONTROL As more states legalize the recreational and medicinal use of cannabis in the United States and Canada, the number of processors

More information

Innovations in Administration and Injection Systems EXPERIENCED CREATIVE FOCUSED

Innovations in Administration and Injection Systems EXPERIENCED CREATIVE FOCUSED Innovations in Administration and Injection Systems EXPERIENCED CREATIVE FOCUSED Meeting Your Drug Administration Challenges Your injectable drug product will be perfectly pure when you ship it, but will

More information

Other Major Component Inspection II

Other Major Component Inspection II Other Major Component Inspection II Ultrasonic Inspection Technique for BWR Shroud Support Plate Access Hole Covers S.W. Glass III, B. Thigpen, Areva, France BACKGROUND Access hole covers (AHC) are found

More information

ISO 1567 INTERNATIONAL STANDARD. Dentistry Denture base polymers. Art dentaire Polymères pour base de prothèses dentaires. Third edition

ISO 1567 INTERNATIONAL STANDARD. Dentistry Denture base polymers. Art dentaire Polymères pour base de prothèses dentaires. Third edition INTERNATIONAL STANDARD ISO 1567 Third edition 1999-02-15 Dentistry Denture base polymers Art dentaire Polymères pour base de prothèses dentaires A Reference number Contents 1 Scope...1 2 Normative references...1

More information

RLS/BP MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 300/BP MX 600/ kw RLS 400/BP MX 800/ kw DUAL FUEL.

RLS/BP MX SERIES. Low NOx Modulating Dual Fuel Burners FIRING RATES. RLS 300/BP MX 600/ kw RLS 400/BP MX 800/ kw DUAL FUEL. RLS/BP MX series burners are characterised by a modular monoblock structure that means all necessary components can be combined in a single unit thus making installation easier, faster and, above all,

More information

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document By the Authority Vested By Part 5 of the United States Code 552(a) and Part 1 of the Code of Regulations 51 the attached document has

More information

STANDARD FOR PROCESSED TOMATO CONCENTRATES CODEX STAN * Adopted in Revised in 2007, Amended in 2013.

STANDARD FOR PROCESSED TOMATO CONCENTRATES CODEX STAN * Adopted in Revised in 2007, Amended in 2013. STANDARD FOR PROCESSED TOMATO CONCENTRATES CODEX STAN 57-1981* Adopted in 1981. Revised in 2007, 2017. Amended in 2013. * Formerly CAC/RS 57-1972. CODEX STAN 57-1981 2 1. SCOPE This Standard applies to

More information

HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual

HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT. Instruction Manual HCS70004P, HCS70004G HCS70004C, HCS70004BL HCS70004DP, HCS70004 AEROMIST COLORS NEBULIZER COMPRESSOR KIT Instruction Manual TABLE OF CONTENTS IEC Symbols...2 Important Safeguards...2 Introduction...3 Specifications...4

More information

I AM SAFER. Reliable X-ray technology that reduces radiation exposure

I AM SAFER. Reliable X-ray technology that reduces radiation exposure I AM SAFER Reliable X-ray technology that reduces radiation exposure EN 40 cm / 80 cm / 110 cm (16 / 31 / 43 ) 70 cm (27 ) 9 cm (3,5 ) 36 cm (14 ) 79 cm / 119 cm / 149 cm (31 / 46 / 59 ) 87 cm (34 ) 81

More information

Ordering Information. ProteOn XPR36 System. Protein Interaction Analysis

Ordering Information. ProteOn XPR36 System. Protein Interaction Analysis Protein Interaction Analysis Ordering Information ProteOn XPR36 System The ProteOn XPR36 system is an optical biosensor capable of simultaneously measuring 36 individual molecular interactions. It integrates

More information

Safe. Clean. Rapid. DAC UNIVERSAL cleans, lubricates and sterilizes at the touch of a button

Safe. Clean. Rapid. DAC UNIVERSAL cleans, lubricates and sterilizes at the touch of a button CAD/CAM SYSTEMS INSTRUMENTS HYGIENE SYSTEMS TREATMENT CENTERS IMAGING SYSTEMS DAC UNIVERSAL cleans, lubricates and sterilizes at the touch of a button Safe. Clean. Rapid. DAC UNIVERSAL The hygiene formula

More information

10 Sulfaquinoxaline H N O S O. 4-amino-N-quinoxalin-2-ylbenzenesulfonamide C 14 H 12 N 4 O 2 S MW: CAS No.:

10 Sulfaquinoxaline H N O S O. 4-amino-N-quinoxalin-2-ylbenzenesulfonamide C 14 H 12 N 4 O 2 S MW: CAS No.: 10 Sulfaquinoxaline N N H N O S O NH 2 4-amino-N-quinoxalin-2-ylbenzenesulfonamide C 14 H 12 N 4 O 2 S MW: 300.33 CAS No.: 59-40-5 Outline of sulfaquinoxaline Sulfaquinoxaline is light yellow to brownish

More information

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories

International Atomic Energy Agency. Department of Nuclear Sciences and Applications. IAEA Environment Laboratories International Atomic Energy Agency Department of Nuclear Sciences and Applications IAEA Environment Laboratories Vienna International Centre, P.O. Box 100, 1400 Vienna, Austria REFERENCE SHEET CERTIFIED

More information

RLS/M MZ SERIES. Modulating Dual Fuel Burners FIRING RATES DUAL FUEL

RLS/M MZ SERIES. Modulating Dual Fuel Burners FIRING RATES DUAL FUEL The RLS/M MZ series of burners covers a fi ring range from 550 to 2460 kw, and they have been designed for use in hot or superheated water boilers, hot air or steam generators, diathermic oil boilers.

More information

Plastic Storage Bottles. Product Selection Guide

Plastic Storage Bottles. Product Selection Guide Plastic Product Selection Guide Contents Page Introduction... 1 Physical Properties of Plastic Bottles... 1 Comparison of Plastic.... 2 Polystyrene (PS).... 3 Accessories for PS.... 3 Square Polycarbonate

More information

EXPERIMENT 4 DETERMINATION OF REDUCING SUGARS, TOTAL REDUCING SUGARS, SUCROSE AND STARCH

EXPERIMENT 4 DETERMINATION OF REDUCING SUGARS, TOTAL REDUCING SUGARS, SUCROSE AND STARCH Practical Manual Food Chemistry and Physiology EXPERIMENT 4 DETERMINATION OF REDUCING SUGARS, TOTAL REDUCING SUGARS, SUCROSE AND STARCH Structure 4.1 Introduction Objectives 4.2 Experiment 4a: Reducing

More information

Elcometer 138/2. Surface Contamination Kit. Operating Instructions

Elcometer 138/2. Surface Contamination Kit. Operating Instructions Elcometer 138/2 English Surface Contamination Kit Operating Instructions R English is a registered trademark of Elcometer Limited. All other trademarks acknowledged. Copyright Elcometer Limited. 2010.

More information

Reprocessing Guide. Autoclavable Arthroscope and Hardware Sterilization Tray

Reprocessing Guide. Autoclavable Arthroscope and Hardware Sterilization Tray Reprocessing Guide Autoclavable Arthroscope and Hardware Sterilization Tray 0233032116 Contents Introduction...2 Intended Use of Sterilization Trays...4 Warnings...5 Cautions...5 Instructions...6 Sterilization

More information

12 series (Pneufit) Push-in fittings Ø 1/8... 1/2, Ø mm tube size, BSP and NPT threads

12 series (Pneufit) Push-in fittings Ø 1/8... 1/2, Ø mm tube size, BSP and NPT threads 2 series (Pneufit) Push-in fittings Ø /8... /2, Ø 4... 2 mm tube size, SP and NPT threads Very compact units asy tube insertion for rapid assembly of pneumatic circuits Positive tube anchorage ll taper

More information

Safety Data Sheet. according to Regulation (EC) No 1907/2006. SECTION 1: Identification of the substance/mixture and of the company/undertaking

Safety Data Sheet. according to Regulation (EC) No 1907/2006. SECTION 1: Identification of the substance/mixture and of the company/undertaking Sterngold Dental, LLC Page 1 of 5 SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier EZ Pickup 10ml 1.2. Relevant identified uses of the substance

More information

Quick Sealing with a Twist to Connect Actuation Method

Quick Sealing with a Twist to Connect Actuation Method - Finger tighten seals up to 689 bar (10,000 psi) for pneumatic and hydraulic testing - Safe and Reliable leak tight connections to male and female threads - Eliminate thread damage, sealant and wrenches

More information

ab ATP Synthase Enzyme Activity Microplate Assay Kit

ab ATP Synthase Enzyme Activity Microplate Assay Kit ab109714 ATP Synthase Enzyme Activity Microplate Assay Kit Instructions for Use For the quantitative measurement of ATP Synthase activity in samples from Human, Rat and Cow This product is for research

More information

Safety Data Sheet. SECTION 1: Identification of the substance/mixture and of the company/undertaking

Safety Data Sheet. SECTION 1: Identification of the substance/mixture and of the company/undertaking Product code: 110368, 110400-110404, 110406 (1300_GHS) Page 1 of 5 SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier 1.2. Relevant identified uses

More information