Introduction. Paulo de Tarso Ponte Pierre-Filho, 1 Rui Barroso Schimiti, 1 Jose Paulo Cabral de Vasconcellos 1 and Vital Paulino Costa 1,2

Size: px
Start display at page:

Download "Introduction. Paulo de Tarso Ponte Pierre-Filho, 1 Rui Barroso Schimiti, 1 Jose Paulo Cabral de Vasconcellos 1 and Vital Paulino Costa 1,2"

Transcription

1 ACTA OPHTHALMOLOGICA SCANDINAVICA 2006 Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, SITA Standard and SITA Fast perimetry in perimetrically inexperienced individuals Paulo de Tarso Ponte Pierre-Filho, 1 Rui Barroso Schimiti, 1 Jose Paulo Cabral de Vasconcellos 1 and Vital Paulino Costa 1,2 1 Glaucoma Service, Department of Ophthalmology, University of Campinas, São Paulo, Brazil 2 Glaucoma Service, Department of Ophthalmology, University of Sa o Paulo, Sa o Paulo, Brazil ABSTRACT. Purpose: To evaluate the sensitivity and specificity of the screening modes of frequency-doubling technology (FDT), tendency-oriented perimetry (TOP), SITA Standard (SS) and SITA Fast (SF) in perimetrically inexperienced individuals. Methods: One eye of 64 glaucoma patients and 53 normal subjects who had never undergone automated perimetry were tested with programs C-20-5 (FDT), G1 (TOP) and 24-2 (SS and SF). The gold standard for glaucoma was the presence of a typical glaucomatous optic disc appearance on stereoscopic examination (judged by a glaucoma expert), and intraocular pressure (IOP) > 21 mmhg. The test order among strategies was randomized for each subject. To define an abnormal visual field, we applied three criteria for SS and SF and two criteria for TOP and FDT, all of which have been previously described in the literature. Sensitivities and specificities among the different criteria were compared using the Cochran test. Results: Frequency-doubling technology showed the shortest mean test duration, followed by TOP, SF and SS (p < 0.05). Sensitivity ranges were % for SS, % for SF, % for TOP, and % for FDT (p = 0.34). Specificity ranges were % for FDT, % for TOP, % for SF and % for SS. The specificity obtained with criterion 2 for FDT (based on the presence of two or more abnormal locations regardless of the severity of abnormal points) was higher than those measured with the other strategies (p < 0.01). Conclusion: When testing individuals with no perimetric experience, moderate sensitivities and specificities should be expected, regardless of the strategy chosen. Key words: visual field perimetry sensitivity specificity glaucoma screening Acta Ophthalmol. Scand. 2006: 84: Copyright # Acta Ophthalmol Scand doi: /j x Introduction Glaucoma is a significant cause of blindness worldwide. The estimated number of people suffering from glaucoma in the year 2000 was approximately 67 million, 10% of whom were bilaterally blind (Quigley 1996). The fact that glaucoma blindness is irreversible, but often develops after a slowly progressive asymptomatic stage, calls for the development of improved methods of early detection (Quigley 1996). Although early detection of glaucoma is fundamental to reducing progression to blindness, an optimal screening method has remained elusive. Screening methods need to be accurate, rapid, inexpensive, easily administered, reliable, and highly sensitive and specific (Katz et al. 1993; Quigley 1996). Although direct optic disc observation by glaucoma specialists is considered an ideal method, applying this method to large mass screening is impossible. As an alternative, screening methods using simple and rapid visual field (VF) tests have been suggested (Katz et al. 1993; Sponsel et al. 1995). Automated perimetry has been the gold standard for the detection and 345

2 ACTAOPHTHALMOLOGICA SCANDINAVICA 2006 monitoring of functional loss in glaucoma for the past three decades (Fankhauser et al. 1972; Bebie et al. 1976). Numerous attempts have been made to improve the sensitivity, specificity and speed of data acquisition, in order to help reduce the fatigue induced by the test (Bengtsson et al. 1997; Bengtsson & Heijl 1998a; Johnson 2002). The Humphrey Swedish Interactive Threshold Algorithm (SITA) has greatly reduced testing time without reducing data quality, compared with the full-threshold (FT) strategy (Bengtsson et al. 1997). The SITA includes two different programs: SITA Standard (SS) and SITA Fast (SF). The SS strategy test time is nearly 50% shorter than that of FT (Bengtsson et al. 1997), while SF is even more rapid than SS (Bengtsson & Heijl 1998a). Another fast strategy called tendency-oriented perimetry (TOP) was introduced in Octopus perimeters to obtain an approximation of the VF threshold in a much shorter period of time than traditional strategies. The TOP strategy is based on testing each position only once, but interpolating the information to the surrounding areas (Morales et al. 2000; Gonzales de la Rosa et al. 2003). Frequency-doubling technology (FDT) presents stimuli on a black-andwhite video monitor. The stimulus is a low spatial frequency sinusoidal grating that undergoes a 25-Hz counterphase flicker. Seventeen VF locations are evaluated in a short testing time (Kalaboukhova & Lindblom 2003). Furthermore, FDT may detect functional loss in glaucoma patients earlier than standard white-on-white perimetry (Quigley 1998; Medeiros et al. 2004). The purpose of our study was to examine the sensitivity and specificity of four rapid VF tests (FDT, TOP, SF and SS) in normal subjects and glaucoma patients who had never undergone automated perimetry. Materials and Methods The study was approved by the Ethics Committee of the University of Campinas. Written informed consent was then obtained from consecutive subjects selected from February to November After a complete ophthalmological examination, including visual acuity (VA) measurement, slit-lamp biomicroscopy, Goldmann applanation tonometry, gonioscopy and optic disc evaluation (with the pupils dilated and using a 78-dioptre lens), patients were included in the study if appropriate criteria were met. One eye per subject was randomly included in the analysis. All recruited subjects were 18 years or older, had not previously undergone automated perimetry, had corrected VA of 20/50 and a spherical equivalent of 5D. Subjects were excluded if they presented with a history of systemic or ocular disease other than glaucoma that might interfere with visual field results. We also excluded pseudophakic eyes and those with significant cataract greater than moderate lens opacification, according to the Lens Opacity Classification System III (Chylack et al. 1993). The diagnosis of glaucoma was based on the presence of typical glaucomatous optic disc damage (i.e. cup : disc ratio 0.6, localized rim loss, optic disc haemorrhage, or cupto-disc asymmetry > 0.2), and intraocular pressure (IOP) > 21 mmhg. Normal subjects were recruited from volunteers among spouses, friends, relatives or accompanying persons of patients and had IOP < 21 mmhg, optic disc examination graded as normal and no family history of glaucoma. Visual field data were not used as inclusion criteria for either group, as this would have generated an important source of bias, artificially increasing the sensitivity and specificity of VF tests (Garway-Heath & Hitchings 1998). After appropriate instruction, all participants were tested with the FDT C-20-5 program (Zeiss Humphrey Systems, Dublin, California, USA), the Octopus 301 G1-TOP program (Interzeag, Schlieren, Switzerland), and the SS and SF 24-2 program using the Humphrey Field Analyser II (model 750, Version A-10; Zeiss Humphrey Systems, Dublin, California, USA) with appropriate refractive correction (except for in FDT), during a single visit on the same day. The order of tests was randomly chosen for each subject, with an interval of approximately mins between each test. The technician conducting VF examinations was masked to the underlying diagnosis. In the FDT C-20-5 program, the test stimuli are presented at contrast levels corresponding to the normal 5% of probability level. If the stimulus is detected, no further testing is performed in that location. If the stimulus is missed, a repeat presentation at the 5% probability level is made at the same location. If it is missed again, a stimulus at the 2% probability level is presented, and if this is missed, a 1% probability level stimulus is presented. The result at each location is labelled to one of the following values: p 5% (normal), p < 5% (mild defect), p < 2% (moderate defect), p < 1% (severe defect) (Johnson & Samuels 1997; Joson et al. 2002; Anderson & Johnson 2003). Two different criteria (previously described in the literature) were used to define an abnormal FDT test: (1) the presence of at least one abnormal location (Burnstein et al. 2000), and (2) the presence of two or more abnormal locations regardless of the severity of abnormal points (Quigley 1998). The TOP strategy tests each point only once, but each point is affected by the responses of the surrounding points to reach the final threshold approximation. The TOP examinations were performed with an Octopus 301 perimeter connected to and controlled by an external personal computer (PC). The TOP test was considered abnormal if: (1) the mean defect (MDe) > 2dB and/or the loss variance (LV) > 6 db, and (2) there were at least seven points (three of them contiguous) with a reduction in sensitivity 5 db in the corrected comparisons graphic (Sponsel et al. 1995; Morales et al. 2000; Wadood et al. 2002). The new SITA strategies use models of normal and typically altered VFs. The threshold values and measurement errors are constantly estimated during the test, which is interrupted when measurement errors have been reduced to a predetermined level (Bayesian posterior probability function) (Bengtsson et al. 1997). Sita Standard and Sita Fast were performed using a size III white stimulus on a white background (31.5 apostilbs or 10 cd/m 2 ). Results for SS and SF were considered abnormal if: 346

3 ACTA OPHTHALMOLOGICA SCANDINAVICA 2006 (1) the glaucoma hemifield test (GHT) was borderline or outside normal limits; (2) the pattern deviation probability map showed a cluster of three or more non-edge points deviating at p < 5%, with one of them deviating at p < 1%, or (3) the pattern standard deviation (PSD) was increased to values deviating at p < 5% (Wadood et al. 2002). Sita Standard and Sita Fast tests were considered reliable if fixation losses were < 20%, and false-positive and false-negative answers were < 33%. Tendency-oriented perimetry VFs with > 33% false-positive and/or false-negative responses or a reliability factor > 15% were considered unreliable. Frequency-doubling technology was considered unreliable when falsepositive responses and/or fixation errors were > 33.3%. After all examinations had been performed, glaucoma subjects were further classified according to the mean deviation (MD) obtained with SS as having early (MD > 6 db), moderate ( 6dBMD > 12 db), or severe (MD 12 db) glaucoma (Iwasaki et al. 2002). Initially, a global analysis was performed, comparing the results of all tests, regardless of the order in which they were applied. A second analysis, which included the results of only the first examination of each patient, was performed in order to exclude the possible learning effect observed in subsequent examinations. The sensitivity and specificity of the above two criteria for FDT, two criteria for TOP, and three criteria for SS and SF were compared. Statistical analyses were performed with SAS Version 8.20 (SAS Institute Inc., Cary, North Carolina, USA). Demographic and clinical characteristics between the two groups were compared using chi-squared and twotailed Student s t-tests for categorical and continuous variables, respectively. Differences among proportions were determined using the chi-squared test, Fisher s exact test or the Cochran test as appropriate. Times for test completion (which did not include the time spent entering data, instructing the patient and printing out the result) were compared using the Friedman test or Student s t-test. A p-value < 0.05 was considered statistically significant. Data are reported as mean SD where applicable. Results A total of 117 eyes, 53 normal and 64 glaucomatous, were enrolled in this study. Among the 64 glaucomatous eyes, 21 (32.8%), 12 (18.8%) and 31 (48.4%) were classified as having early, moderate and severe glaucoma, respectively. Demographic data for the study subjects are listed in Table 1. The mean age in the glaucoma group ( years, range years) was significantly higher than in the normal group ( years, range years) (p < ). Black people accounted for 24.8% of the individuals and were more frequent in the glaucoma group (p < 0.05). The cup : disc ratio was significantly higher among glaucoma patients than in the normal group (p < ). The mean test duration was mins for SS, mins for SF, mins for TOP, and mins for FDT. The mean test time was significantly lower for FDT (p < ). Glaucomatous patients had longer test times and more unreliable visual fields than normal subjects for all tests, even when we controlled for differences in age (Tables 2 and 3). The Cochran test showed significant differences in reliability indices among the different tests, with TOP presenting more unreliable results in both normal subjects (p ¼ 0.019) and glaucoma patients (p < ) (Table 3). The sensitivity and the specificity of each criterion for each test are shown in Table 4. When all tests were evaluated using the previously described criteria, regardless of the order in which they were performed, sensitivities ranged as follows: % for FDT; % for TOP; % for SF, and % for SS. There was no statistically significant difference between the sensitivities obtained with each perimetric test (p ¼ 0.34). Specificities varied as follows: % for FDT; % for Table 1. Demographic data. TOP; % for SF, and % for SS. The specificity obtained with criterion 2 for FDT (based on the presence of two or more abnormal locations regardless of the severity of abnormal points) was higher than those measured with the other strategies (p < 0.01). There was no significant difference regarding the distribution of early, moderate and severe glaucoma among patients undergoing the different examinations as a first test (p ¼ 0.223) (Table 5). Table 6 shows the sensitivity and specificity of each test considering only the first examinations of each patient. When only the first tests were evaluated using the criteria described previously, sensitivities were 78.6% for FDT, 94.1% for TOP, 89.5% for SS, and in the range of % for SF. There was no statistically significant difference between the sensitivities obtained with each perimetric test (p ¼ 0.63). Specificities were 76.9% for FDT and in the range of % for TOP, % for SF and % for SS. There was no statistically significant difference between the specificities obtained with each perimetric test (p ¼ 0.65). Discussion Automated perimetry has become an essential component in the successful diagnosis and follow-up of glaucoma. Some studies have been designed to evaluate the sensitivity and specificity of different visual field tests in perimetrically experienced patients (Burnstein et al. 2000; Wadood et al. 2002; Kalaboukhova & Lindblom 2003). It has been shown that individuals with no perimetric experience may exhibit a learning effect, thus reducing test accuracy and reliability (Joson et al. 2002; Budenz et al. 2002; Schimiti et al. 2002). When performing large-scale, mass screening for glaucoma, researchers often face a number of individuals Normal subjects Glaucoma patients p-value Number (n) Sex (M/F) 25/28 27/ Age (years SD) < Race (Black/White/Asians) 8/44/1 21/43/ Cup : disc ratio <

4 ACTAOPHTHALMOLOGICA SCANDINAVICA 2006 Table 2. Average time (minutes) required for each test (ANCOVA corrected for age). Total (n ¼ 117) Normal subjects (n ¼ 53) Glaucoma patients (n ¼ 64) p-value FDT < TOP SF < SS < FDT ¼ frequency-doubling technology; TOP ¼ tendency-oriented perimetry; SF ¼ Humphrey SITA Fast; SS ¼ Humphrey SITA Standard. Table 3. Percentage of reliable visual field tests in normal subjects and glaucoma patients. (corrected for age by logistic regression). Normal subjects (n ¼ 53) Glaucoma patients (n ¼ 64) p-value FDT 96.2% 92.2% 0.79 TOP 83.0% 56.2% 0.06 SF 94.2% 93.7% 0.44 SS 98.1% 93.7% 0.29 FDT ¼ frequency-doubling technology. TOP ¼ tendency-oriented perimetry. SF ¼ Humphrey SITA Fast. SS ¼ Humphrey SITA Standard. with no previous perimetric experience. In this study, we compared the diagnostic performance of the FDT screening mode C-20-5, the Octopus G1-TOP program, and the SS and SF program 24 2 for the Humphrey Field Analyser II in subjects undergoing automated perimetry for the first time. The new perimetric tests FDT, TOP, SF and SS may offer important advantages over standard automated perimetry because of the reduced time required to administer the test, especially for elderly people (Bengtsson & Heijl 1998b; Budenz et al. 2002; Delgado et al. 2002; Iwasaki et al. 2002; Schimiti et al. 2002; Wadood et al. 2002; Kalaboukhova & Lindblom 2003). In this study, SS had the longest test duration and FDT was the fastest (p < ). The shorter time required for FDT may be explained by the 17 test locations for FDT as compared with the 54 points evaluated with TOP, SF and SS. Moreover, FDT employs a suprathreshold screening strategy, whereas the other strategies aim to determine the threshold of each tested location. Surprisingly, the TOP strategy showed the lowest number of reliable tests in both normal subjects and glaucoma patients. Different methodologies used to derive reliability indices may explain discrepancies between reliability estimates. Table 4. Sensitivities and specificities with their respective confidence intervals for each criterion of each test. Test* Sensitivity Specificity % (95% CI) % (95% CI) FDT (1) 85.9 ( ) 73.6 ( ) FDT (2) 82.8 ( ) 83.0 ( ) TOP (1) 87.5 ( ) 56.6 ( ) TOP (2) 89.1 ( ) 62.3 ( ) SF (1) 93.8 ( ) 60.4 ( ) SF (2) 92.2 ( ) 67.8 ( ) SF (3) 92.2 ( ) 69.8 ( ) SS (1) 89.1 ( ) 66.0 ( ) SS (2) 89.1 ( ) 66.0 ( ) SS (3) 87.5 ( ) 71.7 ( ) p-value 0.34 < 0.01 * Refer to text for details of criteria for each test. CI ¼ confidence interval. In addition to being rapid, a screening test needs to be associated with high sensitivity and specificity. Table 7 lists the sensitivities and specificities obtained with all tested instruments in previous studies with perimetrically experienced individuals. Although comparisons with these studies are limited by different sample characteristics and different inclusion criteria, it is evident that their sensitivities and specificities are generally higher than those reported herein (Tables 4 and 6), which suggests that perimetrically inexperienced individuals do not perform as well as experienced patients. Despite the widespread adoption of the SITAs for detection and follow-up of glaucomatous visual field defects, relatively little has been published on the sensitivity of these two algorithms when the gold standard for glaucoma is based on optic disc examination. Although SS was not designed specifically for screening purposes, its short test duration prompted us to include it in this comparison. In one of the few studies that compared FT and SS in 80 normal individuals with no perimetric experience, using criteria described by Anderson & Patella (1992) to define abnormality, the specificity of SS varied from 60% to 77.5% when each single criterion was analysed, and was 50% when the fulfilment of any criteria was enough to define abnormality (Schimiti et al. 2002). These findings were confirmed in our study, where specificities obtained with SS ranged from 66% to 71.7%. It was interesting to observe that, although SS provides more information than suprathreshold strategies such as the FDT screening program, its sensitivity and specificity were not significantly different from the other tests. With any diagnostic test, evaluation of its sensitivity and specificity provides important information about its usefulness, especially with regard to screening. In this study, we found moderate sensitivities and specificities for all strategies. We also observed that criterion 2 of FDT (based on the presence of two or more abnormal locations regardless of the severity of abnormal points) was associated with better specificity than other previously described criteria for other instruments. Similarly, the sensitivities and specificities obtained with each instrument when only first examinations 348

5 ACTA OPHTHALMOLOGICA SCANDINAVICA 2006 Table 5. Distribution of early, moderate and severe glaucoma among patients according to the first examination. Severity of glaucoma FDT (n ¼ 14) TOP (n ¼ 17) SF (n ¼ 14) SS (n ¼ 19) Early Moderate Severe p ¼ Table 6. Sensitivities and specificities with their respective confidence intervals for only the first examinations of each patient. Test* n Sensitivity Specificity % (95% CI) % (95% CI) FDT (1) ( ) 76.9 ( ) FDT (2) ( ) 76.9 ( ) TOP (1) ( ) 53.9 ( ) TOP (2) ( ) 61.5 ( ) SF (1) ( ) 57.1 ( ) SF (2) ( ) 64.3 ( ) SF (3) ( ) 71.4 ( ) SS (1) ( ) 84.6 ( ) SS (2) ( ) 76.9 ( ) SS (3) ( ) 84.6 ( ) p-value * Refer to text for details of criteria for each test. CI ¼ confidence interval. were analysed did not appear to be significantly different (p > 0.05). Our study has important limitations. The ideal strategy to compare sensitivities and specificities of different instruments includes the construction of ROC curves, or the comparison of sensitivities at a fixed specificity. In this study, we aimed to compare the sensitivities and specificities of different instruments using criteria that had been previously described in the literature. This does not allow for the construction of ROC curves. Some have employed ROC curves derived from one data point (Wadood et al. 2002), but this represents an approximation that is not appropriate. Similarly, setting the specificity at a fixed value and comparing sensitivities is very difficult when categorical data are used as criteria. Because it is a clinic-based study including a proportion of glaucomatous cases that is significantly higher than that expected in the general population, our findings may not be applicable to the general population. Furthermore, our exclusion criteria selected a population free of other Table 7. Sensitivities and specificities of FDT, TOP, SS, and SF in previously published studies. Author Test Criteria* Disease definition Sensitivity Specificity Burnstein et al. (2000) FDT C-20-1 FDT (1) Abnormal HFA fields 85.7% 83.3% Quigley (1998) FDT C-20-1 FDT (2) Abnormal HFA fields 91% 94.0% Kalaboukhova & Lindblom (2003) FDT C-20-5 FDT score > 1 Abnormal optic nerves 91.7% 87.8% Patel et al. (2000) FDT C-20-1 Own algorithm Abnormal HFA fields 80% 93.0% Trible et al. (2000) FDT C-20-1 FDT (1) Clinical diagnosis and 39%, 86% and 100% 95.0% abnormal HFA fields Wadood et al. (2002) TOP-G1 TOP (1) Abnormal optic nerves 97% 68.0% TOP-G1 TOP (2) 94% 82.0% SF 24-2 SF (1) 98.5% 67.8% SF 24-2 SF (2) 95.7% 75.0% SF 24-2 SF (3) 94.2% 82.1% FDT C-20-1 FDT (1) 91.4% 96.4% FDT C-20-1 FDT (2) 80% 100% Morales et al. (2000) TOP-G1 TOP (1) Abnormal Octopus % 87.0% TOP-G1 TOP (2) 89% 90.0% Shekar et al. (2000) SS 30-2 SS (1) Abnormal HFA fields 95.1% NA SF 30-2 SS (1) 92.7% NA Sharma et al. (2000) SS 24-2 SS (1) Abnormal HFA fields 93.2% 79.0% King et al. (2002) SF 24-2 SF (1) Clinical diagnosis 88.3% 93.8% SF 24-2 SF (2) 86.4% 82.4% SF 24-2 SF (3) 89.2% 80.0% TOP-G1 TOP (1) 85.2% 86.7% TOP-G1 TOP (2) 84.7% 76.5% * Refer to text for details of criteria for each test. The FDT score was calculated as follows: normal areas (p 5%) were assigned a value of 0; areas with p < 5% were graded as 1; those with p < 2% as 2, and those with p < 1% as 3 on the basis of FDT grey-scale printout. For early, moderate, and severe glaucoma. FDT ¼ frequency-doubling technology; TOP ¼ tendency-oriented perimetry; SF ¼ Humphrey SITA Fast; SS ¼ Humphrey SITA Standard; HFA ¼ Humphrey field analyser; NA ¼ not available. 349

6 ACTAOPHTHALMOLOGICA SCANDINAVICA 2006 ocular diseases (such as cataract), which is not the case in populationbased screening. Finally, our sample size was relatively small, resulting in wide confidence intervals and possibly reducing the chances of finding differences between strategies. Nevertheless, we were able to determine that fast strategies are associated with reduced performance in individuals undergoing VF examinations for the first time. When testing individuals with no perimetric experience, a situation typically observed during population screening, moderate sensitivities and specificities are expected, regardless of the strategy chosen. These findings suggest that relying on a single rapid VF test in a screening setting is not appropriate. Although these tests certainly represent an advance in the functional evaluation of glaucomatous patients, the confirmation of initial results and/or the employment of additional tests (including the analysis of structural damage) are required for accurate diagnosis. References Anderson AJ & Johnson CA (2003): Frequency-doubling technology perimetry. Ophthalmol Clin North Am 16: Anderson DR & Patella VM (1992): Automated Static Perimetry. St. Louis, Missouri: Mosby Bebie H, Frankhauser F & Spahr J (1976): Static perimetry. Acta Ophthalmol (Copenh) 54: Bengtsson B & Heijl A (1998a): SITA Fast, a new rapid perimetric threshold test: description of methods and evaluation in patients with manifest and suspect glaucoma. Acta Ophthalmol Scand 76: Bengtsson B & Heijl A (1998b): Evaluation of a new perimetric threshold strategy, SITA, in patients with manifest and suspect glaucoma. Acta Ophthalmol Scand 76: Bengtsson B, Olsson J, Heijl A & Rootzén H (1997): A new generation of algorithms for computerized threshold perimetry: SITA. Acta Ophthalmol Scand 75: Budenz DL, Rhee P, Feuer WJ, McSoley J, Johnson CA & Anderson DR (2002): Sensitivity and specificity of the Swedish Interactive Threshold Algorithm for glaucomatous visual field defects. Ophthalmology 109: Burnstein Y, Ellish NJ, Magbalon M & Higginbotham EJ (2000): Comparison of frequency-doubling perimetry with Humphrey visual field analysis in a glaucoma practice. Am J Ophthalmol 129: Chylack LT, Wolfe JK & Singer DM et al. (1993): The Lens Opacities Classification System III. Arch Ophthalmol 111: Delgado MF, Nguyen NT & Cox TA et al. & the American Academy of Ophthalmology Ophthalmic Technology Assessment Committee Glaucoma Panel (2002): Automated Perimetry. A report by the American Academy of Ophthalmology. Ophthalmology 109: Fankhauser F, Koch P & Roulier A (1972): On automation of perimetry. Graefes Arch Clin Exp Ophthalmol 184: Garway-Heath DF & Hitchings RA (1998): Sources of bias in studies of optic disc and retinal nerve fibre layer morphology. Br J Ophthalmol 82: 986. Gonzales de la Rosa M, Morales J & Dannheim F et al. (2003): Multicentre evaluation of tendency-oriented perimetry (TOP) using the G1 grid. Eur J Ophthalmol 13: Iwasaki A, Sugita M & Glaucoma Screening Project Study Group (2002): Performance of glaucoma mass screening with only a visual testing using frequency-doubling technology perimetry. Am J Ophthalmol 134: Johnson CA (2002): Recent developments in automated perimetry in glaucoma diagnosis and management. Curr Opin Ophthalmol 13: Johnson CA & Samuels SJ (1997): Screening for glaucomatous visual field loss with frequency-doubling perimetry. Invest Ophthalmol Vis Sci 38: Joson PJ, Kamantigue ME & Chen PP (2002): Learning effects among perimetric novices in frequency-doubling technology perimetry. Ophthalmology 109: Kalaboukhova L & Lindblom B (2003): Frequency-doubling technology and highpass resolution perimetry in glaucoma and ocular hypertension. Acta Ophthalmol Scand 81: Katz J, Tielsch JM, Quigley HA, Javitt J, Will K & Sommer A (1993): Automated suprathreshold screening for glaucoma: the Baltimore Eye Survey. Invest Ophthalmol Vis Sci 34: King AJ, Taguri A, Wadood AC & Azuara- Blanco A (2002): Comparison of two fast strategies, SITA Fast and TOP, for the assessment of visual fields in glaucoma patients. Graefes Arch Clin Exp Ophthalmol 240: Medeiros FA, Sample PA & Weinreb RN (2004): Frequency-doubling technology perimetry as predictors of glaucomatous visual field loss. Am J Ophthalmol 137: Morales J, Weitzman ML & Gonzales de la Rosa M (2000): Comparison between tendency-oriented perimetry (TOP) and Octopus threshold perimetry. Ophthalmology 107: PatelSC,FriedmanDS,VaradkarP&RobinAL (2000): Algorithm for interpreting the results of frequency-doubling perimetry. Am J Ophthalmol 129: Quigley HA (1996): Number of people with glaucoma worldwide. Br J Ophthalmol 80: Quigley HA (1998): Identification of glaucoma-related visual field abnormality with the screening protocol of frequencydoubling technology. Am J Ophthalmol 125: Schimiti RB, Avelino RR, Kara-José N & Costa VP (2002): Full-threshold versus Swedish Interactive Threshold Algorithm (SITA) in normal individuals undergoing automated perimetry for the first time. Ophthalmology 109: Sharma AK, Goldberg I, Graham SL & Mohsin M (2000): Comparison of the Humphrey Swedish Interactive Threshold Algorithm (SITA) and full-threshold strategies. J Glaucoma 9: Shekar GC, Naduvilath TJ, Lakkai M, Jayakumar AJ, Pandi GT, Mandal AK & Honovar SG (2000): Sensitivity of Swedish Interactive Threshold Algorithm in Humphrey visual field testing. Ophthalmology 107: Sponsel WE, Ritch R, Stamper R, Higginbotham EJ, Anderson DR, Wilson MR & Zimmerman TJ (1995): Prevent Blindness America visual field screening study. The Prevent Blindness America Glaucoma Advisory Committee. Am J Ophthalmol 120: Trible JR, Schultz RO, Robinson JC & Roth TL (2000): Accuracy of glaucoma detection with frequency-doubling perimetry. Am J Ophthalmol 129: Wadood AC, Azuara-Blanco A, Aspinall LL, Taguri A & King AJ (2002): Sensitivity and specificity of frequency-doubling technology, tendency-oriented perimetry, and Humphrey Swedish Interactive Threshold Algorithm Fast perimetry in a glaucoma practice. Am J Ophthalmol 133: Received on February 24th, Accepted on November 14th, Correspondence: Paulo de Tarso P. Pierre-Filho MD Rua Visconde de Mauá 470/500 Fortaleza-CE CEP Brazil Tel: þ paulooft@unicamp.br. 350

Access to the published version may require journal subscription. Published with permission from: Elsevier

Access to the published version may require journal subscription. Published with permission from: Elsevier This is an author produced version of a paper published in Ophthalmology. This paper has been peer-reviewed but does not include the final publisher proof-corrections or journal pagination. Citation for

More information

Test-retest variability in visual field testing using frequency doubling technology

Test-retest variability in visual field testing using frequency doubling technology European Journal of Ophthalmology / Vol. 17 no. 2, 2007 / pp. 203-207 Test-retest variability in visual field testing using frequency doubling technology A. HORANI, S. FRENKEL, E.Z. BLUMENTHAL Department

More information

Discrimination between normal and glaucomatous eyes with visual field and scanning laser polarimetry measurements

Discrimination between normal and glaucomatous eyes with visual field and scanning laser polarimetry measurements 586 Glaucoma Service, Department of Ophthalmology, University of Campinas, Campinas, Brazil R Lauande-Pimentel R A Carvalho H C Oliveira D C Gonçalves L M Silva V P Costa Glaucoma Service, Department of

More information

STANDARD AUTOMATED PERIMETRY IS A GENERALLY

STANDARD AUTOMATED PERIMETRY IS A GENERALLY Comparison of Long-term Variability for Standard and Short-wavelength Automated Perimetry in Stable Glaucoma Patients EYTAN Z. BLUMENTHAL, MD, PAMELA A. SAMPLE, PHD, LINDA ZANGWILL, PHD, ALEXANDER C. LEE,

More information

3/16/2018. Perimetry

3/16/2018. Perimetry Perimetry The normal visual field extends further away from fixation temporally and inferiorly than superiorly and nasally. From the center of the retina this sensitivity decreases towards the periphery,

More information

CHAPTER 6 SELECTING A TEST STRATEGY INTRODUCTION. accurate but shorter test may yield more useful visual

CHAPTER 6 SELECTING A TEST STRATEGY INTRODUCTION. accurate but shorter test may yield more useful visual 81 CHAPTER 6 SELECTING A TEST STRATEGY INTRODUCTION As illustrated in Chapter 4, determining sensitivity thresholds by assessing all levels of stimulus intensity (e.g., stimulus luminance) is not practical

More information

CORRELATING OF THE VISUAL FIELD INDEX WITH MEAN DEVIATION AND PATTERN STANDARD DEVIATION IN GLAUCOMA PATIENTS

CORRELATING OF THE VISUAL FIELD INDEX WITH MEAN DEVIATION AND PATTERN STANDARD DEVIATION IN GLAUCOMA PATIENTS CORRELATING OF THE VISUAL FIELD INDEX WITH MEAN DEVIATION AND PATTERN STANDARD DEVIATION IN GLAUCOMA PATIENTS Bui Thi Huong Giang, Pham Thi Kim Thanh Department of Ophthamology, Hanoi Medical University

More information

CLINICAL SCIENCES. Glaucoma Monitoring in a Clinical Setting

CLINICAL SCIENCES. Glaucoma Monitoring in a Clinical Setting CLINICAL SCIENCES Glaucoma Monitoring in a Clinical Setting Glaucoma Progression Analysis vs Nonparametric Progression Analysis in the Groningen Longitudinal Glaucoma Study Christiaan Wesselink, MD; Govert

More information

Misleading Statistical Calculations in Faradvanced Glaucomatous Visual Field Loss

Misleading Statistical Calculations in Faradvanced Glaucomatous Visual Field Loss Misleading Statistical Calculations in Faradvanced Glaucomatous Visual Field Loss Eytan Z. Blumenthal, MD, Ruthy Sapir-Pichhadze, MD Objective: In this study, the capability of statistical analysis indices

More information

CLINICAL SCIENCES. (FDP) was designed to emphasize the response characteristics of the parasol

CLINICAL SCIENCES. (FDP) was designed to emphasize the response characteristics of the parasol CLINICAL SCIENCES Detecting Visual Function Abnormalities Using the Swedish Interactive Threshold Algorithm and Matrix Perimetry in Eyes With Glaucomatous Appearance of the Optic Disc Lisandro M. Sakata,

More information

Citation for published version (APA): Wesselink, C. (2017). Glaucoma care optimised in an ageing population [Groningen]: Rijksuniversiteit Groningen

Citation for published version (APA): Wesselink, C. (2017). Glaucoma care optimised in an ageing population [Groningen]: Rijksuniversiteit Groningen University of Groningen Glaucoma care optimised in an ageing population Wesselink, Christiaan IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from

More information

Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD

Noel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD Original Article Philippine Journal of OPHTHALMOLOGY Diagnostic Accuracy of the Optical Coherence Tomography in Assessing Glaucoma Among Filipinos. Part 1: Categorical Outcomes Based on a Normative Database

More information

Citation for published version (APA): Stoutenbeek, R. (2010). Population based glaucoma screening Groningen: s.n.

Citation for published version (APA): Stoutenbeek, R. (2010). Population based glaucoma screening Groningen: s.n. University of Groningen Population based glaucoma screening Stoutenbeek, Remco IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check

More information

Fluctuation of Intraocular Pressure and Glaucoma Progression in the Early Manifest Glaucoma Trial

Fluctuation of Intraocular Pressure and Glaucoma Progression in the Early Manifest Glaucoma Trial Fluctuation of Intraocular Pressure and Glaucoma Progression in the Early Manifest Glaucoma Trial Boel Bengtsson, PhD, 1 M. Cristina Leske, MD, MPH, 2 Leslie Hyman, PhD, 2 Anders Heijl, MD, PhD, 1 Early

More information

F requency doubling technology (FDT) perimetry was

F requency doubling technology (FDT) perimetry was 131 EXTENDED REPORT Clinical evaluation of frequency doubling technology perimetry using the Humphrey Matrix 24-2 threshold strategy P G D Spry, H M Hussin, J M Sparrow... See end of article for authors

More information

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma Med. J. Cairo Univ., Vol. 83, No. 2, September: 67-72, 2015 www.medicaljournalofcairouniversity.net Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma

More information

T he retinal ganglion cells of different sizes have distinct

T he retinal ganglion cells of different sizes have distinct 604 CLINICAL SCIENCE Agreement between frequency doubling perimetry and static perimetry in eyes with high tension glaucoma and normal tension glaucoma S Kogure, Y Toda, D Crabb, K Kashiwagi, F W Fitzke,

More information

Visual Fields Shawn L. Cohen, M.D. Part 2 of 4. Definitions / Tables (Part 2 of 2) Static Perimetry (Humphrey, Octopus)

Visual Fields Shawn L. Cohen, M.D. Part 2 of 4. Definitions / Tables (Part 2 of 2) Static Perimetry (Humphrey, Octopus) Visual Fields Shawn L. Cohen, M.D. Part 2 of 4 Definitions / Tables (Part 2 of 2) Static Perimetry (Humphrey, Octopus) Normal Visual Field: Components: General Information Reliability Indices Raw Data

More information

Science & Technologies

Science & Technologies STANDARD COMPUTERIZED PERIMETRY IN FUNCTION OF DIAGNOSTIC GLAUCOMA Iljaz Ismaili, 1 Gazepov Strahil, 2, Goshevska Dashtevska Emilija 1 1 University Eye Clinic,Skopje 2 Clinical Hospital, Shtip Abstract

More information

21st Century Visual Field Testing

21st Century Visual Field Testing Supplement to Supported by an educational grant from Carl Zeiss Meditec, Inc. Winter 2011 21st Century Visual Field Testing the Evolution Continues 21st Century Visual Field Testing 21st Century Visual

More information

CLINICAL SCIENCES. Screening for Glaucoma With Frequency-Doubling Technology and Damato Campimetry

CLINICAL SCIENCES. Screening for Glaucoma With Frequency-Doubling Technology and Damato Campimetry CLINICAL SCIENCES Screening for Glaucoma With Frequency-Doubling Technology and Damato Campimetry Noriko Yamada, MD; Philip P. Chen, MD; Richard P. Mills, MD; Martha M. Leen, MD; Marc F. Lieberman, MD;

More information

Fluctuations on the Humphrey and Octopus Perimeters

Fluctuations on the Humphrey and Octopus Perimeters May 987 Vol. 28/ Investigative Ophthalmology & Visual Science A Journal of Dosic and Clinical Research Articles Fluctuations on the and Perimeters Randall S. Drenton and William A. Argus Fluctuation of

More information

A comparison of HRT II and GDx imaging for glaucoma detection in a primary care eye clinic setting

A comparison of HRT II and GDx imaging for glaucoma detection in a primary care eye clinic setting (2007) 21, 1050 1055 & 2007 Nature Publishing Group All rights reserved 0950-222X/07 $30.00 www.nature.com/eye CLINICAL STUDY A comparison of HRT II and GDx imaging for glaucoma detection in a primary

More information

Intro to Glaucoma/2006

Intro to Glaucoma/2006 Intro to Glaucoma/2006 Managing Patients with Glaucoma is Exciting Interesting Challenging But can often be frustrating! Clinical Challenges To identify patients with risk factors for possible glaucoma.

More information

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements

Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements Original article Comparative evaluation of time domain and spectral domain optical coherence tomography in retinal nerve fiber layer thickness measurements Dewang Angmo, 1 Shibal Bhartiya, 1 Sanjay K Mishra,

More information

Correspondence should be addressed to Verena Prokosch;

Correspondence should be addressed to Verena Prokosch; Hindawi Ophthalmology Volume 2017, Article ID 8014294, 6 pages https://doi.org/10.1155/2017/8014294 Research Article Comparison between the Correlations of Retinal Nerve Fiber Layer Thickness Measured

More information

Investigative Ophthalmology & Vision Sciences MSc Course. Glaucoma Module. Visual Field Reliability Indices. David Henson 2014.

Investigative Ophthalmology & Vision Sciences MSc Course. Glaucoma Module. Visual Field Reliability Indices. David Henson 2014. Investigative Ophthalmology & Vision Sciences MSc Course Glaucoma Module Visual Field Reliability Indices David Henson 214 Variability 1 Variability Clinical problem How can we judge whether the change

More information

Glaucoma: Diagnostic Modalities

Glaucoma: Diagnostic Modalities Glaucoma: Diagnostic Modalities - Dr. Barun Kumar Nayak, Dr. Sarika Ramugade Glaucoma is a leading cause of blindness in the world, especially in older people. Early detection and treatment by ophthalmologist

More information

Baseline Visual Field Characteristics in the Ocular Hypertension Treatment Study

Baseline Visual Field Characteristics in the Ocular Hypertension Treatment Study Baseline Visual Field Characteristics in the Ocular Hypertension Treatment Study Chris A. Johnson, PhD, 1 John L. Keltner, MD, 2 Kimberly E. Cello, BS, 2 Mary Edwards, BS, 2 Michael A. Kass, MD, 3 Mae

More information

CHAPTER 10 NON-CONVENTIONAL PERIMETRY

CHAPTER 10 NON-CONVENTIONAL PERIMETRY 193 CHAPTER 10 NON-CONVENTIONAL PERIMETRY INTRODUCTION Static Standard Automated Perimetry (SAP, alternatively called white-on-white perimetry), which uses a white Goldmann size III stimulus presented

More information

Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography

Retinal nerve fiber layer thickness in Indian eyes with optical coherence tomography Original articles in Indian eyes with optical coherence tomography Malik A, Singh M, Arya SK, Sood S, Ichhpujani P Department of Ophthalmology Government Medical College and Hospital, Sector 32, Chandigarh,

More information

Comparative study of new imaging technologies for the diagnosis of glaucoma: Protocol Approved by the Ethics Committee

Comparative study of new imaging technologies for the diagnosis of glaucoma: Protocol Approved by the Ethics Committee Comparative study of new imaging technologies for the diagnosis of glaucoma: Protocol Approved by the Ethics Committee HTA 09/22/111. Applicants: Augusto Azuara-Blanco (CI), Jennifer Burr,, Rodolfo Hernández,

More information

OCTOPUS 300 Perimetry you can trust

OCTOPUS 300 Perimetry you can trust OCTOPUS 300 Perimetry you can trust Tradition and innovation Since 1858, visionary thinking and a fascination with technology have guided us to develop innovative products of outstanding reliability: Anticipating

More information

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography

Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography Original Article Philippine Journal of OPHTHALMOLOGY Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography Dennis L. del Rosario, MD and Mario M. Yatco, MD University of Santo

More information

The improvement in perimetric results occurring over

The improvement in perimetric results occurring over ORIGINAL STUDY Learning Effect of Humphrey Matrix Frequency Doubling Technology Perimetry in Patients With Ocular Hypertension Marco Centofanti, MD, PhD,*w Paolo Fogagnolo, MD,w Francesco Oddone, MD,w

More information

Financial Disclosure. Visual Field Interpretation RELIABILITY VISUAL FIELD INTERPRETATION IN GLAUCOMA METHODS OF DATA PRESENTATION

Financial Disclosure. Visual Field Interpretation RELIABILITY VISUAL FIELD INTERPRETATION IN GLAUCOMA METHODS OF DATA PRESENTATION VISUAL FIELD INTERPRETATION IN GLAUCOMA Danica J. Marrelli, OD, FAAO University of Houston College of Optometry Financial Disclosure I have received speaking and/or consulting fees from: Aerie Pharmaceutical

More information

Persistence, Spatial Distribution and Implications for Progression Detection of Blind Parts of the Visual Field in Glaucoma: A Clinical Cohort Study

Persistence, Spatial Distribution and Implications for Progression Detection of Blind Parts of the Visual Field in Glaucoma: A Clinical Cohort Study Persistence, Spatial Distribution and Implications for Progression Detection of Blind Parts of the Visual Field in Glaucoma: A Clinical Cohort Study Francisco G. Junoy Montolio 1., Christiaan Wesselink

More information

CLINICAL SCIENCES. Comparison of Glaucoma Diagnostic Capabilities of Cirrus HD and Stratus Optical Coherence Tomography

CLINICAL SCIENCES. Comparison of Glaucoma Diagnostic Capabilities of Cirrus HD and Stratus Optical Coherence Tomography CLINICAL SCIENCES Comparison of Glaucoma Diagnostic Capabilities of Cirrus HD and Stratus Optical Coherence Tomography Seong Bae Park, MD; Kyung Rim Sung, MD, PhD; Sung Yong Kang, MD; Kyung Ri Kim, BS;

More information

Study of Retinal Nerve Fiber Layer Thickness Within Normal Hemivisual Field in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma

Study of Retinal Nerve Fiber Layer Thickness Within Normal Hemivisual Field in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma Study of Retinal Nerve Fiber Layer Thickness Within Normal Hemivisual Field in Primary Open-Angle Glaucoma and Normal-Tension Glaucoma Chiharu Matsumoto, Shiroaki Shirato, Mai Haneda, Hiroko Yamashiro

More information

CLINICAL SCIENCES. Steven L. Mansberger, MD; Pamela A. Sample, PhD; Linda Zangwill, PhD; Robert N. Weinreb, MD

CLINICAL SCIENCES. Steven L. Mansberger, MD; Pamela A. Sample, PhD; Linda Zangwill, PhD; Robert N. Weinreb, MD CLINICAL SCIENCES Achromatic and Short-Wavelength Automated Perimetry in Patients With Glaucomatous Large Cups Steven L. Mansberger, MD; Pamela A. Sample, PhD; Linda Zangwill, PhD; Robert N. Weinreb, MD

More information

VISUAL FIELD TESTING OCCUpies

VISUAL FIELD TESTING OCCUpies CLINICAL SCIENCES Prediction of Glaucomatous Visual Field Loss by Extrapolation of Linear Trends Boel Bengtsson, PhD; Vincent Michael Patella, OD; Anders Heijl, MD, PhD Objective: To investigate how well

More information

Learning Effect and Test-Retest Variability in Healthy Subjects and Patients with Primary Open Angle Glaucoma Using Rarebit Perimetry

Learning Effect and Test-Retest Variability in Healthy Subjects and Patients with Primary Open Angle Glaucoma Using Rarebit Perimetry International Journal of Pharmaceutical Science Invention ISSN (Online): 2319 6718, ISSN (Print): 2319 670X Volume 6 Issue 4 April 2017 PP. 38-43 Learning Effect and Test-Retest Variability in Healthy

More information

Visual Field Interpretation Anthony B. Litwak, OD, FAAO VA Medical Center Baltimore, MD

Visual Field Interpretation Anthony B. Litwak, OD, FAAO VA Medical Center Baltimore, MD Visual Field Interpretation Anthony B. Litwak, OD, FAAO VA Medical Center Baltimore, MD Dr. Litwak is on the speaker bureau and advisory panel for Alcon and Zeiss Meditek o Confirms Glaucoma Diagnosis!

More information

Spontaneous Intraocular Pressure Reduction in Normal-Tension Glaucoma and Associated Clinical Factors

Spontaneous Intraocular Pressure Reduction in Normal-Tension Glaucoma and Associated Clinical Factors CLINICAL INVESTIGATIONS Spontaneous Intraocular Pressure Reduction in Normal-Tension Glaucoma and Associated Clinical Factors Akihiro Oguri, Tetsuya Yamamoto and Yoshiaki Kitazawa Department of Ophthalmology,

More information

Prevalence Of Primary Open Angle Glaucoma in Diabetic Patients

Prevalence Of Primary Open Angle Glaucoma in Diabetic Patients IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 16, Issue 6 Ver. III (June. 2017), PP 147-151 www.iosrjournals.org Prevalence Of Primary Open Angle Glaucoma

More information

Characteristics of Frequency-of-Seeing Curves in Normal Subjects, Patients With Suspected Glaucoma, and Patients With Glaucoma

Characteristics of Frequency-of-Seeing Curves in Normal Subjects, Patients With Suspected Glaucoma, and Patients With Glaucoma Characteristics of Frequency-of-Seeing Curves in Normal Subjects, Patients With Suspected Glaucoma, and Patients With Glaucoma Balwantray C. Chauhan* James D. Tompkins,-\ Raymond P. LeBlanc* and Terry

More information

City, University of London Institutional Repository

City, University of London Institutional Repository City Research Online City, University of London Institutional Repository Citation: Artes, P. H., O'Leary, N., Nicolela, M. T., Chauhan, B. C. and Crabb, D. P. (2014). Visual Field Progression in Glaucoma

More information

NERVE FIBER LAYER THICKNESS IN NORMALS AND GLAUCOMA PATIENTS

NERVE FIBER LAYER THICKNESS IN NORMALS AND GLAUCOMA PATIENTS Nerve fiber layer thickness in normals and glaucoma patients 403 NERVE FIBER LAYER THICKNESS IN NORMALS AND GLAUCOMA PATIENTS HIROTAKA SUZUMURA, KAYOKO HARASAWA, AKIKO KOBAYASHI and NARIYOSHI ENDO Department

More information

CLINICAL SCIENCES. Fellow Eye Prognosis in Patients With Severe Visual Field Loss in 1 Eye From Chronic Open-Angle Glaucoma

CLINICAL SCIENCES. Fellow Eye Prognosis in Patients With Severe Visual Field Loss in 1 Eye From Chronic Open-Angle Glaucoma Fellow Eye Prognosis in Patients With Severe Visual Field Loss in 1 Eye From Chronic Open-Angle Glaucoma Philip P. Chen, MD; Anuja Bhandari, FRCOphth CLINICAL SCIENCES Objectives: To examine the prognosis

More information

Perimetry Phobia: Don t fear the field Savory Turman, COMT, CPSS

Perimetry Phobia: Don t fear the field Savory Turman, COMT, CPSS Perimetry Phobia: Don t fear the field Savory Turman, COMT, CPSS I have no financial interest in this presentation. Who am I? Where am I? What am I? The anatomy of the visual field Purpose of Visual Field

More information

IPS Standards and Guidelines 2010

IPS Standards and Guidelines 2010 IPS Standards and Guidelines 2010 PREFACE In 1978, the Perimetric Standards and Perimetric Glossary of the International Council of Ophthalmology was developed and published by the IPS Research Group on

More information

Comparison of Visual Field Measurement with Heidelberg Edge Perimeter and Humphrey Visual Field Analyzer in Patients with Ocular Hypertension

Comparison of Visual Field Measurement with Heidelberg Edge Perimeter and Humphrey Visual Field Analyzer in Patients with Ocular Hypertension ORIGINAL PAPERS Adv Clin Exp Med 2016, 25, 5, 937 944 DOI: 10.17219/acem/62142 Copyright by Wroclaw Medical University ISSN 1899 5276 Kamil Kaczorowski 1, B E, Małgorzata Mulak 1, A, C, E, Dorota Szumny

More information

LUP. Lund University Publications Institutional Repository of Lund University

LUP. Lund University Publications Institutional Repository of Lund University LUP Lund University Publications Institutional Repository of Lund University This is an author produced version of a paper published in Ophthalmology. This paper has been peerreviewed but does not include

More information

Diurnal IOP fluctuation: not an independent risk factor for glaucomatous visual field loss in high-risk ocular hypertension.

Diurnal IOP fluctuation: not an independent risk factor for glaucomatous visual field loss in high-risk ocular hypertension. Diurnal IOP fluctuation: not an independent risk factor for glaucomatous visual field loss in high-risk ocular hypertension. Bengtsson, Boel; Heijl, Anders Published in: Graefe's Archive for Clinical and

More information

Diagnosing open-angle glaucoma may be particularly

Diagnosing open-angle glaucoma may be particularly A New Look at Selective Perimetry What is its role in clinical practice? BY MURRAY FINGERET, OD Diagnosing open-angle glaucoma may be particularly challenging when damage is mild or early. Although most

More information

Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects

Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects Romanian Journal of Ophthalmology, Volume 60, Issue 3, July-September 2016. pp:158-164 GENERAL ARTICLE Translating data and measurements from stratus to cirrus OCT in glaucoma patients and healthy subjects

More information

S Morishita, T Tanabe, S Yu, M Hangai, T Ojima, H Aikawa, N Yoshimura. Clinical science

S Morishita, T Tanabe, S Yu, M Hangai, T Ojima, H Aikawa, N Yoshimura. Clinical science Department of Ophthalmology and Visual Sciences, Kyoto University Graduate School of Medicine, Kyoto, Japan Correspondence to: Dr T Tanabe, Department of Ophthalmology, The Tazuke Kofukai Medical Institute,

More information

The Role of the RNFL in the Diagnosis of Glaucoma

The Role of the RNFL in the Diagnosis of Glaucoma Chapter 1. The Role of the RNFL in the Diagnosis of Glaucoma Introduction Glaucoma is an optic neuropathy characterized by a loss of of retinal ganglion cells and their axons, the Retinal Nerve Fiber Layer

More information

Author(s) Sekiya, Takuro; Yoshimura, Nagahisa. Citation Japanese journal of ophthalmology (

Author(s) Sekiya, Takuro; Yoshimura, Nagahisa. Citation Japanese journal of ophthalmology ( Title Concentric division of 10 visual f pigmentosa. Author(s) Ogino, Ken; Otani, Atsushi; Oishi, Sekiya, Takuro; Yoshimura, Nagahisa Citation Japanese journal of ophthalmology ( Issue Date 2013-05 URL

More information

FORUM Glaucoma Workplace from ZEISS Clinical Interpretation Guide

FORUM Glaucoma Workplace from ZEISS Clinical Interpretation Guide FORUM Glaucoma Workplace from ZEISS Clinical Interpretation Guide ZEISS FORUM Glaucoma Workplace.0 For years, doctors have asked for the operational capability to analyze data from their Humphrey Field

More information

THE DEMOGRAPHICS OF THE

THE DEMOGRAPHICS OF THE EPIDEMIOLOGY SECTION EDITOR: LESLIE HYMAN, PhD The Prevalence of Open-angle Glaucoma Among Blacks and Whites 73 Years and Older The Salisbury Eye Evaluation Glaucoma Study David S. Friedman, MD, MPH; Henry

More information

MOVE IT OR LOSE IT: THE ROLE OF KINETIC VISUAL FIELDS

MOVE IT OR LOSE IT: THE ROLE OF KINETIC VISUAL FIELDS MOVE IT OR LOSE IT: THE ROLE OF KINETIC VISUAL FIELDS Course Objectives Review the visual field Review types of perimetry Discuss advantages and disadvantages of different types of visual field testing

More information

Scanning Laser Polarimetry in Patients with Acute Attack of Primary Angle Closure

Scanning Laser Polarimetry in Patients with Acute Attack of Primary Angle Closure Scanning Laser Polarimetry in Patients with Acute Attack of Primary Angle Closure Jimmy S. M. Lai*, Clement C. Y. Tham, Jonathan C. H. Chan*, Nelson K. F. Yip, Wilson W. T. Tang, Patrick S. H. Li*, Jane

More information

Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma

Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma Role of Central Corneal Thickness in Circadian Intraocular Pressure Fluctuations among Patients with Primary Open Angle Glaucoma Mohannad Albdour MD*, Karanjit Kooner MD, PHD** ABSTRACT Objectives: To

More information

Diagnostic Accuracy of OCT with a Normative Database to Detect Diffuse Retinal Nerve Fiber Layer Atrophy: Diffuse Atrophy Imaging Study METHODS

Diagnostic Accuracy of OCT with a Normative Database to Detect Diffuse Retinal Nerve Fiber Layer Atrophy: Diffuse Atrophy Imaging Study METHODS Glaucoma Diagnostic Accuracy of OCT with a Normative Database to Detect Diffuse Retinal Nerve Fiber Layer Atrophy: Diffuse Atrophy Imaging Study Jin Wook Jeoung, 1,2 Seok Hwan Kim, 1,3 Ki Ho Park, 1,2

More information

Correlation of Blue Chromatic Macular Sensitivity with Optic Disc Change in Early Glaucoma Patients

Correlation of Blue Chromatic Macular Sensitivity with Optic Disc Change in Early Glaucoma Patients Correlation of Blue Chromatic Macular Sensitivity with Optic Disc Change in Early Glaucoma Patients Yoshio Yamazaki, Kenji Mizuki, Fukuko Hayamizu and Chizuru Tanaka Department of Ophthalmology, Nihon

More information

Scanning laser polarimetry (SLP) provides real-time, objective

Scanning laser polarimetry (SLP) provides real-time, objective The Effect of Atypical Birefringence Patterns on Glaucoma Detection Using Scanning Laser Polarimetry with Variable Corneal Compensation Christopher Bowd, Felipe A. Medeiros, Robert N. Weinreb, and Linda

More information

PREVALENCE OF GLAUCOMA AMONG FISHERMEN COMMUNITY OF MUNDRA TALUKA OF KUTCH DISTRICT- A CROSS- SECTIONAL STUDY

PREVALENCE OF GLAUCOMA AMONG FISHERMEN COMMUNITY OF MUNDRA TALUKA OF KUTCH DISTRICT- A CROSS- SECTIONAL STUDY ORIGINAL RESEARCH PREVALENCE OF GLAUCOMA AMONG FISHERMEN COMMUNITY OF MUNDRA TALUKA OF KUTCH DISTRICT- A CROSS- SECTIONAL STUDY Sanjay Upadhyay 1, Jayantilal Shah 2 1 Assistant Professor, 2 Associate Professor,

More information

Clinical Guidance and Monitoring for Change. Cecilia Fenerty MD FRCOphth Manchester Royal Eye Hospital

Clinical Guidance and Monitoring for Change. Cecilia Fenerty MD FRCOphth Manchester Royal Eye Hospital Clinical Guidance and Monitoring for Change Cecilia Fenerty MD FRCOphth Manchester Royal Eye Hospital Glaucoma Referral Criteria 2000 Original referral scheme Simple criteria based on IOP/Disc/Field Solitary

More information

Effect of brimonidine on intraocular pressure in normal tension glaucoma: A short term clinical trial

Effect of brimonidine on intraocular pressure in normal tension glaucoma: A short term clinical trial European Journal of Ophthalmology / Vol. 13 no. 7, 2003 / pp. 611-615 Effect of brimonidine on intraocular pressure in normal tension glaucoma: A short term clinical trial S.A. GANDOLFI, L. CIMINO, P.

More information

Ganglion cell complex scan in the early prediction of glaucoma

Ganglion cell complex scan in the early prediction of glaucoma Original article in the early prediction of glaucoma Ganekal S Nayana Super Specialty Eye Hospital and Research Center, Davangere, Karnataka, India Abstract Objective: To compare the macular ganglion cell

More information

A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT) Retinal Nerve Fiber Layer Measurements Based on Time Domain OCT Measurements

A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT) Retinal Nerve Fiber Layer Measurements Based on Time Domain OCT Measurements pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2012;26(5):369-377 http://dx.doi.org/10.3341/kjo.2012.26.5.369 Original Article A Formula to Predict Spectral Domain Optical Coherence Tomography (OCT)

More information

Central Corneal Thickness-An important variable for prognostication in Primary Open Angle glaucoma; A Kolkata based study in Eastern India

Central Corneal Thickness-An important variable for prognostication in Primary Open Angle glaucoma; A Kolkata based study in Eastern India Original article: Central Corneal Thickness-An important variable for prognostication in Primary Open Angle glaucoma; A Kolkata based study in Eastern India 1Dr. Apala Bhattacharya, 2 Dr Gautam Bhaduri,

More information

Idiopathic intracranial hypertension (IIH) is a disorder of

Idiopathic intracranial hypertension (IIH) is a disorder of Factors Affecting Visual Field Outcomes in the Idiopathic Intracranial Hypertension Treatment Trial Kimberly E. Cello, BS, John L. Keltner, MD, Chris A. Johnson, PhD, Michael Wall, MD, for the NORDIC Idiopathic

More information

C linical visual field tests are designed to provide. Measurement error of visual field tests in glaucoma LABORATORY SCIENCE

C linical visual field tests are designed to provide. Measurement error of visual field tests in glaucoma LABORATORY SCIENCE 107 LABORATORY SCIENCE Measurement error of visual field tests in glaucoma P G D Spry, C A Johnson, A M McKendrick, A Turpin... Br J Ophthalmol 2003;87:107 112 See end of article for authors affiliations...

More information

The determination of glaucoma progression is based on a. Refinement of Pointwise Linear Regression Criteria for Determining Glaucoma Progression

The determination of glaucoma progression is based on a. Refinement of Pointwise Linear Regression Criteria for Determining Glaucoma Progression Glaucoma Refinement of Pointwise Linear Regression Criteria for Determining Glaucoma Progression Colleen M. Kummet, 1 K. D. Zamba, 2 Carrie K. Doyle, 3 5 Chris A. Johnson, 3,4 and Michael Wall 3 5 1 Department

More information

Optic nerve head morphometry in healthy adults using confocal laser scanning tomography

Optic nerve head morphometry in healthy adults using confocal laser scanning tomography 761 SCIENTIFIC REPORT Optic nerve head morphometry in healthy adults using confocal laser scanning tomography M M Hermann, I Theofylaktopoulos, N Bangard, C Jonescu-Cuypers, S Coburger, M Diestelhorst...

More information

Rarebit perimetry and frequency doubling technology in patients with ocular hypertension

Rarebit perimetry and frequency doubling technology in patients with ocular hypertension European Journal of Ophthalmology / Vol. 18 no. 2, 2008 / pp. 205-211 Rarebit perimetry and frequency doubling technology in patients with ocular hypertension G. CORALLO, M. IESTER, R. SCOTTO, G. CALABRIA,

More information

Quantification of Glaucomatous Visual Field Defects with Automated Perimetry

Quantification of Glaucomatous Visual Field Defects with Automated Perimetry Quantification of Glaucomatous Visual Field Defects with Automated Perimetry J. Flammer,* 5. M. Drance,f L. Augusriny,* and A. Funkhouser* A method to quantify different glaucomatous visual field defects

More information

Lifetime Risk of Blindness in Open-Angle Glaucoma.

Lifetime Risk of Blindness in Open-Angle Glaucoma. Lifetime Risk of Blindness in Open-Angle Glaucoma. Peters, Dorothea; Bengtsson, Boel; Heijl, Anders Published in: American Journal of Ophthalmology DOI: 10.1016/j.ajo.2013.05.027 2013 Link to publication

More information

Clinical decision making based on data from GDx: One year observations

Clinical decision making based on data from GDx: One year observations Washington University School of Medicine Digital Commons@Becker Open Access Publications 2002 Clinical decision making based on data from GDx: One year observations James C. Bobrow Washington University

More information

Expanding your field of vision. Visual Field Analyzers from Carl Zeiss

Expanding your field of vision. Visual Field Analyzers from Carl Zeiss Expanding your field of vision Visual Field Analyzers from Carl Zeiss Vision in focus Visual Field Analyzers Humphrey Field Analyzer/HFA II-i Series Humphrey Matrix Humphrey FDT Perimeter Software Guided

More information

Factors Associated With Visual Field Progression in Cirrus Optical Coherence Tomography-guided Progression Analysis: A Topographic Approach

Factors Associated With Visual Field Progression in Cirrus Optical Coherence Tomography-guided Progression Analysis: A Topographic Approach ORIGINAL STUDY Factors Associated With Visual Field Progression in Cirrus Optical Coherence Tomography-guided Progression Analysis: A Topographic Approach Joong Won Shin, MD, Kyung Rim Sung, MD, PhD, Jiyun

More information

FLICKER-TOP PERIMETRY IN NORMALS AND PATIENTS WITH OCULAR HYPERTENSION AND EARLY GLAUCOMA

FLICKER-TOP PERIMETRY IN NORMALS AND PATIENTS WITH OCULAR HYPERTENSION AND EARLY GLAUCOMA Flicker-TOP perimetry 59 FLICKER-TOP PERIMETRY IN NORMALS AND PATIENTS WITH OCULAR HYPERTENSION AND EARLY GLAUCOMA MANUEL GONZÁLEZ DE LA ROSA, JAVIER RODRÍGUEZ and MANUEL RODRÍGUEZ Hospital Universitario

More information

Discriminating between Normal and Glaucoma-Damaged Eyes with the Heidelberg Retina Tomograph 3

Discriminating between Normal and Glaucoma-Damaged Eyes with the Heidelberg Retina Tomograph 3 Discriminating between Normal and Glaucoma-Damaged Eyes with the Heidelberg Retina Tomograph 3 Antonio Ferreras, MD, PhD, 1 Luís E. Pablo, MD, PhD, 1 José M. Larrosa, MD, PhD, 1 Vicente Polo, MD, PhD,

More information

Incidence of manifest glaucoma

Incidence of manifest glaucoma Incidence of manifest glaucoma BO BENGTSSON British Journal of Ophthalmology, 1989, 73, 483-487 From the Departments ofresearch in Primary Health Care and Experimental Ophthalmology, University of Lund,

More information

Detection of Glaucoma Using Scanning Laser Polarimetry with Enhanced Corneal Compensation

Detection of Glaucoma Using Scanning Laser Polarimetry with Enhanced Corneal Compensation Detection of Glaucoma Using Scanning Laser Polarimetry with Enhanced Corneal Compensation Felipe A. Medeiros, Christopher Bowd, Linda M. Zangwill, Chirag Patel, and Robert N. Weinreb From the Hamilton

More information

Correlating Structure With Function in End-Stage Glaucoma

Correlating Structure With Function in End-Stage Glaucoma C L I N I C A L S C I E N C E Correlating Structure With Function in End-Stage Glaucoma Eytan Z. Blumenthal, MD; Amjad Horani, MD; Rajesh Sasikumar, MD; Chandrasekhar Garudadri, MD; Addepalli Udaykumar,

More information

Sensitivity and specificity of new GDx parameters Colen TP, Tang NEML, Mulder PGH and Lemij HG Submitted for publication CHAPTER 7

Sensitivity and specificity of new GDx parameters Colen TP, Tang NEML, Mulder PGH and Lemij HG Submitted for publication CHAPTER 7 Sensitivity and specificity of new GDx parameters Colen TP, Tang NEML, Mulder PGH and Lemij HG Submitted for publication CHAPTER 7 61 Abstract Purpose The GDx is a scanning laser polarimeter that assesses

More information

Research Article Optic Disc Hemorrhage after Phacoemulsification in Patients with Glaucoma

Research Article Optic Disc Hemorrhage after Phacoemulsification in Patients with Glaucoma ISRN Ophthalmology, Article ID 574054, 5 pages http://dx.doi.org/10.1155/2014/574054 Research Article Optic Disc Hemorrhage after Phacoemulsification in Patients with Glaucoma Karine D. Bojikian, Daniel

More information

T he extent of damage to the optic nerve caused by nonarteritic

T he extent of damage to the optic nerve caused by nonarteritic 1274 EXTENDED REPORT Frequency doubling technology perimetry in non-arteritic ischaemic optic neuropathy with altitudinal defects C A Girkin, G McGwin Jr, J DeLeon-Ortega... See end of article for authors

More information

Receiver operating characteristic (ROC) curves are a wellaccepted

Receiver operating characteristic (ROC) curves are a wellaccepted A Statistical Approach to the Evaluation of Covariate Effects on the Receiver Operating Characteristic Curves of Diagnostic Tests in Glaucoma Felipe A. Medeiros, 1 Pamela A. Sample, 1 Linda M. Zangwill,

More information

Glaucoma Progression. Murray Fingeret, OD

Glaucoma Progression. Murray Fingeret, OD Glaucoma Progression Murray Fingeret, OD Managing glaucoma or glaucoma suspects Summary For patients diagnosed or at risk of glaucoma Stage disease Risk assessment Asses for progression Treatment plan

More information

Research Article The Pattern of Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness Changes in Glaucoma

Research Article The Pattern of Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer Thickness Changes in Glaucoma Hindawi Ophthalmology Volume 2017, Article ID 78365, 8 pages https://doi.org/10.1155/2017/78365 Research Article The Pattern of Retinal Nerve Fiber Layer and Macular Ganglion Cell-Inner Plexiform Layer

More information

Glaucoma surgery with or without adjunctive antiproliferatives in normal tension glaucoma: 2 Visual field progression

Glaucoma surgery with or without adjunctive antiproliferatives in normal tension glaucoma: 2 Visual field progression 696 Glaucoma Unit, Moorfields Eye Hospital, City Road, London EC1V 2PD, UK W L Membrey C Bunce D P Poinoosawmy F W Fitzke R A Hitchings Correspondence to: R A Hitchings roger.hitchings@virgin.net Accepted

More information

Differences between Non-arteritic Anterior Ischemic Optic Neuropathy and Open Angle Glaucoma with Altitudinal Visual Field Defect

Differences between Non-arteritic Anterior Ischemic Optic Neuropathy and Open Angle Glaucoma with Altitudinal Visual Field Defect pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2015;29(6):418-423 http://dx.doi.org/10.3341/kjo.2015.29.6.418 Original Article Differences between Non-arteritic Anterior Ischemic Optic Neuropathy

More information

Present relevant clinical findings of four landmark glaucoma trials OHTS, EMGT, CNTGS and CIGTS.

Present relevant clinical findings of four landmark glaucoma trials OHTS, EMGT, CNTGS and CIGTS. Course title: The Glaucoma Compass Course length: 1 hour +/- 31 slides Corse Description: Even with the technology and available information, glaucoma decision making can still be confusing. How should

More information

Reproducibility of measurements and variability of the classification algorithm of Stratus OCT in normal, hypertensive, and glaucomatous patients

Reproducibility of measurements and variability of the classification algorithm of Stratus OCT in normal, hypertensive, and glaucomatous patients ORIGINAL RESEARCH Reproducibility of measurements and variability of the classification algorithm of Stratus OCT in normal, hypertensive, and glaucomatous patients Alfonso Antón 1,2,3 Marta Castany 1,2

More information

Research Article Relationship between Spectral-Domain Optical Coherence Tomography and Standard Automated Perimetry in Healthy and Glaucoma Patients

Research Article Relationship between Spectral-Domain Optical Coherence Tomography and Standard Automated Perimetry in Healthy and Glaucoma Patients BioMed Research International, Article ID 514948, 7 pages http://dx.doi.org/10.1155/2014/514948 Research Article Relationship between Spectral-Domain Optical Coherence Tomography and Standard Automated

More information