Intraocular pressure changes and relationship. Corneal Biomechanics After SMILE and FS-LASIK

Size: px
Start display at page:

Download "Intraocular pressure changes and relationship. Corneal Biomechanics After SMILE and FS-LASIK"

Transcription

1 Cornea Intraocular Pressure Changes and Relationship With Corneal Biomechanics After SMILE and FS-LASIK Hua Li, Yan Wang, Rui Dou, Pinghui Wei, Jiamei Zhang, Wei Zhao, and Liuyang Li Tianjin Eye Hospital & Eye Institute, Tianjin Key Lab of Ophthalmology and Visual Science, Tianjin Medical University, Tianjin, China Correspondence: Yan Wang, Tianjin Eye Hospital & Eye Institute, No. 4 Gansu Road, Heping District, Tianjin , China; wangyan7143@vip.sina.com. Submitted: March 23, 2016 Accepted: June 27, 2016 Citation: Li H, Wang Y, Dou R, et al. Intraocular pressure changes and relationship with corneal biomechanics after SMILE and FS-LASIK. Invest Ophthalmol Vis Sci. 2016;57: DOI: /iovs PURPOSE. The purpose of this article was to evaluate intraocular pressure (IOP) changes and investigate the relationship with corneal biomechanics after small-incision lenticule extraction (SMILE) and femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK). METHODS. A total of 193 eyes of 193 patients who underwent SMILE and FS-LASIK procedures were included in this retrospective study. Data were collected preoperatively and postoperatively, including Goldmann-correlated IOP (IOPg), corneal-compensated IOP (IOPcc), corneal hysteresis (CH), and corneal resistance factor (CRF) by ocular response analyzer, noncontact intraocular pressure (IOP NCT ) by noncontact tonometer, and Ehlers, Shah, Dresden, Kohlhaas, Orssengo/Pye by the Pentacam corrected system. Changes in both groups and differences between groups were evaluated. Multiple linear regression models were constructed to explore factors influencing IOP changes. RESULTS. In SMILE, the IOPg, IOPcc, IOP NCT, and Kohlhaas decreased significantly at 1 month postoperatively (P < 0.01), whereas with the Ehlers formula they significantly increased (P < 0.01). IOPs decreased at 3 and 6 months compared with all preoperative values except Ehlers values (P < 0.01), but there was no significant difference between 3 and 6 months (P > 0.05). In FS-LASIK, the IOPg, IOPcc, and IOP NCT decreased significantly at 1 month (P < 0.01), whereas in the Ehlers and Shah formulas they significantly increased (P < 0.01). Compared with preoperative values, the IOPs decreased at 3 and 6 months except in the Ehlers and Shah formulas (P < 0.01). Only IOPg and IOPcc differed between 3 and 6 months (P < 0.05). The Ehlers and Shah formulas were closer to the preoperative IOP for both groups, with variation approximately 1 at 6 months postoperatively. Preoperative IOP, postoperative corneal resistance factor, corneal hysteresis, and flat keratometry were enrolled into the regression equations. CONCLUSIONS. IOP underestimation after SMILE or FS-LASIK was related to corneal biomechanics as well as preoperative IOP and flat keratometry. IOP after SMILE seem to remain more stable. Accordingly, the Ehlers and Shah formulas were closer to the preoperative IOP. It may be useful to estimate future IOP with the best-fit models after surgery. Keywords: intraocular pressure, small-incision lenticule extraction, femtosecond laser-assisted laser in situ keratomileusis, corneal biomechanics Corneal refractive surgery, such as femtosecond laserassisted laser in situ keratomileusis (FS-LASIK) and smallincision lenticule extraction (SMILE), has emerged as having good efficacy, predictability, safety, and stability for surgical correction of low, moderate, and high myopia. 1 3 However, the central corneal thickness (CCT), the corneal curvature, and corneal biomechanics change after corneal refractive surgery, which may affect intraocular pressure (IOP) measurements. 4 Meanwhile, myopia is a risk factor for open-angle glaucoma, 5 and the routine application of steroids postoperatively will increase the risk of elevated IOP after corneal refractive surgery, even causing steroid-induced glaucoma. 6 In addition, elevated IOP is recognized as the most important risk factor for progressive glaucomatous damage. 7 Therefore, the accurate evaluation of IOP is a great concern for clinicians. Previous studies have showed IOP changes after some refractive surgeries, including photorefractive keratectomy, 8,9 laser-assisted subepithelial keratectomy, 10,11 laser in situ keratomileusis (LASIK), 12 epipolis laser in situ keratomileusis, 13 and FS-LASIK. 14 Up to now, there has been no study regarding IOP change after SMILE, especially a comparison of IOPs between SMILE and FS-LASIK. We therefore decided to conduct a new retrospective study to evaluate IOP changes and the relationship with corneal biomechanics after both surgeries. METHODS Patients The institutional review board at Tianjin Eye Hospital, Tianjin Medical University, approved this study protocol, which adhered to the tenets of the Declaration of Helsinki. All patients provided informed consent for surgery. iovs.arvojournals.org j ISSN: This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

2 Intraocular Pressure Changes After SMILE and FS-LASIK IOVS j August 2016 j Vol. 57 j No. 10 j 4181 This was a retrospective study performed at Tianjin Eye Hospital, and patients with myopia or myopic astigmatism who underwent SMILE or FS-LASIK were enrolled. Inclusion criteria were (1) patients older than 18 years; (2) absence of corneal, ocular, or systemic diseases; (3) refractive diopter maintained stable the past 2 years (change of diopter); (4) patients who wore soft contact lens were off contact lenses for at least 2 weeks and off rigid contact lenses for at least 4 weeks; (5) preoperative noncontact intraocular pressure (IOP NCT ) less than 21 ; (6) no family history of glaucoma; (7) postoperative IOP NCT increase less than 7 11,15 ; (8) and no use of IOP-lowering medications before or after refractive surgery. From a total of 193 eyes, 97 eyes of 97 patients underwent SMILE and 96 eyes of 96 patients underwent FS- LASIK. Measures Patients underwent preoperative measurements of uncorrected distance visual acuity; corrected distance visual acuity; manifest and cycloplegic refractions; IOP NCT, Goldmanncorrelated IOP (IOPg), and corneal-compensated IOP (IOPcc) measured by an Ocular Response Analyzer (ORA), corneal topography, and Pentacam-corrected IOPs by the Scheimpflug tomography system (Pentacam; Oculus GmbH, Wetzlar, Germany). Patients were followed up at 1, 3, and 6 months after surgery. Ocular Response Analyzer The ORA (Reichert, Inc., Depew, NY, USA) was used to measure corneal biomechanics and IOPs. Measured parameters are produced by the dynamic bidirectional applanator based on the two pressure measurements at applanation, P1 in the inward direction and P2 in the outward direction. The four parameters included (1) corneal hysteresis (CH), with CH ¼ a[p1-p2] 16 representing the ability of the cornea to absorb or dampen the applied force; (2) corneal resistance factor (CRF), with CRF ¼ a[p1-0.7p2] þ d described as the whole corneal resistance cumulative effect; (3) IOPg, with IOPg ¼ a[(p1-p2)/ 2] þ c, which were highly correlated with IOPg 17 ; (4) IOPcc, with IOPcc ¼ b[p2-0.43p1] þ e, which compensated for corneal properties in estimating IOP, producing a more accurate value in softer eyes and patients after refractive surgery, 18 where a, b, c, d, and e are calibration and regression constants. For each studied eye, three records were reserved with the signal score higher than 3.5, 19 and the average values were calculated. Noncontact Tonometer The noncontact tonometer (TX-F; Canon, Tokyo, Japan) was used to measure IOP avoiding contact and thus reducing the risk of infection. Some research suggested that IOP NCT had good repeatability and precision. 20 This tonometer records three readings and then calculates the average value automatically. Pentacam Scheimpflug Images The rotating Scheimpflug camera identified 25,000 true elevation points to measure corneal thickness and curvature. It also had five IOP correction formulas to correct IOP. This applied for measurements with the applanation tonometer as well as the NCT. When IOP NCT data were input into Pentacam, Ehlers, Shah, Dresden, Kohlhaas, and Orssengo/Pye formulas, corrected IOPs were generated. The following descriptions explains the calculation of IOP change for the correction formula: (1) Ehlers: IOP change ¼ (545 corneal thickness measured ) 21 ; (2) Shah: IOP change ¼ (550 corneal thickness measured ) 22 ; (3) Dresden: IOP change ¼ (550 corneal thickness measured ) 23 ; 4) Kohlhaas: IOP change ¼ (540 corneal thickness measured )/71 þ (43 K)/2.7 þ ; (5) Orssengo/Pye: IOP change ¼ IOP measured /K. 25 These formulas can correct the effects of corneal thickness and corneal curvature on IOP. Surgical Procedures All surgical procedures were performed by the same surgeon (Y.W.). After routine irrigation of the conjunctival sac and periocular sterilization, topical anesthesia was applied with two to three drops of oxybuprocaine hydrochloride (benoxyl; Santen, Inc., Osaka, Japan) twice before surgery, 5 minutes apart. SMILE Procedure SMILE was performed using only the femtosecond laser platform (Visumax; Carl Zeiss Meditec AG, Jena, Germany), with typical pulse energy of approximately 140 to 150 nj and a pulse repetition rate of 500 khz. Four sequential cleavages were created to make an intrastromal lenticule and a small incision. The laser scanning order was, first, the posterior surface of the refractive lenticule, then the lenticule border, then the anterior surface of the lenticule and, finally, the sidecutting of the 3-mm width incision at the 12:00 location of the cornea. The lenticule diameter was 6.5 mm, and the side-cut angle was 908. The corneal cap thickness was 110 lm, and its diameter was 7.5 mm. A basement of 10 to 15 lm above the lenticule was added to remove the lenticule successfully. FS-LASIK Procedure In the FS-LASIK group, flap creation was performed using the same femtosecond laser with pulse energy at 165 to 175 nj. Flap diameter was 8.0 mm, and the thickness was 100 to 110 lm. The flap hinge was positioned nasally. After lifting the flap, ablation of the stromal bed was performed by an excimer laser system (Allegretto; WaveLight Laser Technologie AG, Erlangen, Germany). Finally, the corneal flap was repositioned. Patients of both groups were medicated with topical 0.5% levofloxacin (Cravit; Santen, Inc.) eye drops four times daily for 2 days, and 0.1% fluorometholone (FML; Flumetholon; Santen, Inc.) was applied four times daily for 2 weeks and then tapered down to once every 2 weeks. Statistical Analysis Statistical analysis was performed using SPSS (version 20.0; IBM Corp., Chicago, IL, USA). In this study, changes were expressed by the D symbol and calculated as preoperative value minus 6- month postoperative value; the thickness of the tissue removed was expressed as lenticule thickness (LT) in the SMILE group and as ablation depth (AD) in the FS-LASIK group. Furthermore, because SMILE uses a unique corneal cutting algorithm, the LT was based on the algebraic sum of spherical power and astigmatic power. In the FS-LASIK group, the spherical equivalent was calculated. The normality of all data samples were checked with the Kolmogorov Smirnov test. The means of all of the IOPs at different examination points within a group were compared by repeated-measures analysis of variance, and the further pairwise comparison used least-significant difference. The Greenhouse Geisser correction was applied to degrees of freedom if sphericity was violated. The comparison of IOP

3 Intraocular Pressure Changes After SMILE and FS-LASIK IOVS j August 2016 j Vol. 57 j No. 10 j 4182 TABLE 1. Parameter Baseline Characteristics of the Eyes by Group SMILE Mean 6 SD FS-LASIK t /v 2 Value P Value Sex, n Male Female Age, y Spherical, D Cylinder, D MRSE, D Mean K, D CCT, lm IOPg, IOPcc, IOP NCT, Ehlers, Shah, Dresden, Orssengo, Kohlhaas, LT or AD, lm <0.001* SD, standard deviation; K, Scheimpflug keratometry; MRSE, manifest refraction spherical equivalent. * P < changes between two groups were performed using independent t-tests. The Pearson correlation coefficient (r) was used to evaluate the correlations between variables. Multiple linear regressions were used to explore factors influencing IOP changes in both groups. P values less than 0.05 were considered statistically significant. RESULTS Table 1 shows the preoperative baseline characteristics of patients by group. In the SMILE and FS-LASIK groups, 97 and 96 eyes completed postoperative examinations at 1 and 3 months, respectively; 44 and 38 of these eyes completed the 6- month follow-up. There were no significant differences between preoperative baseline characteristics. Change in the IOP Measurement Values and Corneal Parameters Over Time Table 2 shows IOPs, CH, CRF, CCT, flat keratometry (Kf), steep keratometry (Ks), and mean keratometry (Km) changes after SMILE and FS-LASIK. In SMILE, the IOPg, IOPcc, IOP NCT, and Kohlhaas decreased significantly at 1 month postoperatively (P < 0.01), whereas in the Ehlers formula, they significantly increased (P < 0.01). All of the IOPs showed severe decreases at the 3- and 6-month follow-ups except for those in Ehlers (P < 0.01), but there were no significant differences between 3 and 6 months (P > 0.05). CH, CRF, CCT, Kf, Ks, and Km decreased significantly at 1, 3, and 6 months when compared TABLE 2. The IOP Measurement Values and Relevant Parameter Variations Pre- and Post-SMILE and FS-LASIK P Value Surgeries IOPs Pre-IOP, Post-1M, Post-3M, Post-6M, Pre- vs. Post-1M Pre- vs. Post-3M Pre- vs. Post-6M Post-1M vs. Post-3M Post-3M vs. Post-6M SMILE IOPg <0.001* <0.001* <0.001* <0.001* IOPcc <0.001* <0.001* <0.001* <0.001* IOP NCT <0.001* <0.001* <0.001* 0.002* Ehlers <0.001* 0.001* 0.007* <0.001* Shah * 0.004* <0.001* Dresden <0.001* <0.001* <0.001* Orssengo <0.001* <0.001* <0.001* Kohlhaas * <0.001* <0.001* <0.001* CH <0.001* <0.001* <0.001* CRF <0.001* <0.001* <0.001* CCT <0.001* <0.001* <0.001* <0.001* Kf <0.001* <0.001* <0.001* 0.001* 0.005* Ks <0.001* <0.001* <0.001* 0.002* 0.004* Km <0.001* <0.001* <0.001* <0.001* 0.005* FS-LASIK IOPg <0.001* <0.001* <0.001* <0.001* 0.018* IOPcc * <0.001* <0.001* <0.001* 0.014* IOP NCT <0.001* <0.001* 0.001* <0.001* Ehlers <0.001* <0.001* <0.001* <0.001* Shah * * Dresden * 0.002* 0.002* Orssengo * 0.001* 0.003* Kohlhaas <0.001* <0.001* 0.005* CH <0.001* <0.001* <0.001* CRF <0.001* <0.001* <0.001* CCT <0.001* <0.001* <0.001* <0.001* 0.041* Kf <0.001* <0.001* <0.001* <0.001* 0.016* Ks <0.001* <0.001* <0.001* <0.001* 0.011* Km <0.001* <0.001* <0.001* <0.001* 0.013* 1M, 1 month; 3M, 3 months; 6M, 6 months. * Significant difference at P < 0.05.

4 Intraocular Pressure Changes After SMILE and FS-LASIK IOVS j August 2016 j Vol. 57 j No. 10 j 4183 TABLE 3. The DIOP per Removed or Ablated Tissue at 6 Months Between SMILE and FS-LASIK Group DIOPg DIOPcc DNCT DEhlers DShah DDresden DOrssengo DKohlhaas SMILE FS-LASIK t value P value 0.001* 0.013* * P < with preoperative values (P < 0.01). CH and CRF showed no significant differences between 1, 3, and 6 months (P > 0.05). In FS-LASIK, the IOPg, IOPcc, and IOP NCT decreased significantly at 1 month (P < 0.01), whereas in the Ehlers and Shah formulas they significantly increased (P < 0.01). All of the IOPs decreased sharply at the 3- and 6-month follow-ups except in the Ehlers and Shah formulas (P < 0.01) when compared with preoperative values. Only IOPg and IOPcc differed between 3 and 6 months (P < 0.05). CH, CRF, CCT, Kf, Ks, and Km decreased significantly at 1, 3, and 6 months when compared with preoperative values (P < 0.01). CH and CRF showed no significant differences between 1 and 3 months (P > 0.05; Table 2). Between-Group Comparisons Table 3 shows IOP variation per removed or ablated tissue (DIOP/LT or AD) between two groups, only DIOPg/AD and DIOPcc/AD in FS-LASIK were higher than DIOPg/LT and DIOPcc/LT in SMILE at the 6-month follow-up (P < 0.05). The Figure shows the DIOP at 1, 3, and 6 months postoperatively, and only DIOPg in FS-LASIK was higher than SMILE at the 6-month follow-up (P < 0.05). Similarly, DCRF, DCH, DKf, DKs, and DKm per removed or ablated tissue in FS- LASIK were higher than in SMILE ( vs , vs , vs , vs , vs ; P ¼ 0.001, 0.009, 0.001, <0.001, <0.001; respectively). Correlation Analysis Table 4 shows the correlations between the DIOPg, DIOPcc, DIOP NCT, and the pre-iop, DCCT, DCRF, DCH, DKm, respectively. The DIOP in the FS-LASIK group had more influencing factors and correlated with DCH and DCRF. In SMILE, the DIOPg, DIOPcc, and DIOP NCT correlated with the pre-iop (r ¼ 0.532, 0.478, 0.512, respectively, P < 0.01). Although in FS- LASIK, the DIOPg, DIOPcc, and DIOP NCT correlated with the pre-iop (r ¼ 0.780, 0.664, 0.614, respectively, P < 0.01). Regression Analysis of DIOP NCT and Influencing Factors Table 2 shows that IOP NCT was stable at 3 months after SMILE and FS-LASIK, so patients completed 3-month follow-ups were analyzed. Considering that IOP NCT was common in clinical examinations, a multiple linear regression analysis of DIOP NCT was created to analyze the relationships between possible preoperative influencing factors (pre-iop, pre-cct, Km, Kf, Ks, CRF, CH, and spherical power and astigmatic power/spherical equivalent) and intraoperative parameters (LT or AD) as well postoperative influencing factors (post-cct, Km, Kf, Ks, CRF, CH) and variations after surgery (DCCT, DKm, DKf, DKs, DCRF, DCH). Multiple linear regression models were constructed to explore the factors influencing DIOP NCT in both groups. Preoperative IOP and postoperative CRF, CH, and Kf were enrolled into regression equations in both groups. Table 5 shows the definite regression coefficients between DIOP NCT FIGURE. The comparisons of DIOPg (A), DIOPcc (B), DEhlers (C), and DShah (D) between the SMILE and FS-LASIK groups and their changes over time (pre- and postoperative 1 month [1M], pre- and postoperative 3 months [3M], and pre- and postoperative 6 months [6M]). The standard error (SE) is shown by the error bar (*P < 0.05).

5 Intraocular Pressure Changes After SMILE and FS-LASIK IOVS j August 2016 j Vol. 57 j No. 10 j 4184 TABLE 4. The Correlation Analysis Between DIOPg, DIOPcc, DIOP NCT, and the Pre-IOP, DCCT, DCRF, DCH, DKm, Respectively r Value and the influencing factors. It is possible to obtain the following two regression equations to evaluate DIOP NCT : after SMILE, DIOP NCT ¼ 5:412 þ 0:768IOP pre 1:892CRF post þ 1:345CH post after FS-LASIK, ðr 2 ¼ 0:520; R 2 adjusted ¼ 0:505Þ; DIOP NCT ¼ 8:612 þ 0:681IOP pre 1:362CRF post þ 0:881CH post 0:327Kf post ðr 2 ¼ 0:571; R 2 adjusted ¼ 0:552Þ: The actual postoperative IOP may be evaluated by the measured IOP plus the DIOP. DISCUSSION DIOPg DIOPcc DIOP NCT SMILE FS-LASIK SMILE FS-LASIK SMILE FS-LASIK Pre-IOP 0.532* 0.780* 0.478* 0.664* 0.512* 0.614* DCCT * * * DKf * DKs * DKm * DCRF 0.647* 0.879* * * DCH * 0.465* * * P < IOP measurement values decreased after both SMILE and FS- LASIK, which was consistent with previous research results. 8 14,19 In this study, corneal biomechanical method ORA combined with NCT were used to investigate the relationship between corneal biomechanics and IOP change. Both tonometers estimated IOP by directing a pulse of air at the cornea, causing it to flatten and allowing an electro-optical collimation detector to evaluate corneal curvature. Both SMILE and FS- LASIK surgeries used a myopic ablation profile to remove tissue from the cornea to correct refractive error. After the surgery, CCT, corneal curvature, and corneal biomechanics decreased significantly, 26 and the corneal structure also changed. These corneal changes altered postsurgical measurement of IOP. 24 The corneal biomechanic parameters from ORA could present CH and CRF, with CH representing the viscoelastic property of the cornea and CRF the corneal elasticity with a strong positive correlation for CCT. The decrease of CH and CRF then indicates the decrease of cornea stiffness. When the IOP was measured, the cornea was more likely to be flattened, so these values were lower and underestimated the real IOP. Some studies suggested that there were no clinical symptoms of low IOP after surgery, based on animal experiments but also on clinical observation. 27 This IOP reduction was an illusion and what really changed were the influencing factors of IOP measurement. In this study, IOP measurement values remained stable at 3 months after SMILE, with CH and CRF also restored at 1 month. Moreover, CCT remained stable at 3 months and corneal curvature kept changing. Although some studies showed that the corneal curvature and CCT were related to IOP reduction, 15,28 Liu and Roberts 29 reported that differences in corneal biomechanics between individuals may contribute more than corneal thickness or curvature to IOP measurement errors, which was consistent with this study. After surgery, patients needed routine application of 0.1% FML to prevent inflammation and refractive regression for 2 months. In a comparative study, 6 weeks of FML treatment resulted in an IOP increase greater than 5 in 8.3% of cases, although topical FML was thought to have less effect on IOP than other steroid agents. 30 All of these possible influencing factors, especially corneal biomechanics, regained stability, and after stopping FML medication, IOP measurement values were stable again. Regarding IOP changes in FS-LASIK, most IOP measurement values remained stable at 3 months except IOPg and IOPcc. Similarly, CCT, Kf, Ks, and Km also did not regain its stability at 3 months except in corneal biomechanics. When compared with SMILE, FS-LASIK induced more keratocyte apoptosis, proliferation, and inflammation, 31 so IOP values after FS-LASIK seemed less stable, which may be a result of corneal structure variation. In both groups, the low IOP readings after surgery resulted in a delayed diagnosis of glaucoma or recognition of ocular hypertensive patients, so it was very important to measure postoperative IOP or the change of IOP in an accurate way. Interestingly, the decrease in postoperative 6-month IOP in the current study was significant when measured using NCT (approximately 5 ) and IOPg (approximately 6 ) when compared with IOPcc (approximately 3 ) and Pentacam (approximately 2 ). This finding is supported by the hypothesis that IOPcc is less influenced by corneal properties, such as CCT, and does not decrease significantly following LASIK and epipolis laser in situ keratomileusis. 13 Furthermore, among all of the DIOP after SMILE, DShah was smallest (0.83 ), followed by DEhlers ( 0.87 ). After FS-LASIK, DShah was the smallest (0.35 ) and DEhlers second ( 1.43 ). The comparison between DEhlers and DShah showed no significant difference. Accord- TABLE 5. The Regression Coefficients of Influencing Factors Enrolled Into the Equation Variable Group Unstandardized Coefficients Standardized Coefficients t Value P Value 95% CI Constant SMILE , FS-LASIK , pre-iop NCT SMILE , FS-LASIK , post-crf SMILE , FS-LASIK , post-ch SMILE , FS-LASIK , post-kf FS-LASIK , CI, confidence interval.

6 Intraocular Pressure Changes After SMILE and FS-LASIK IOVS j August 2016 j Vol. 57 j No. 10 j 4185 ingly, the Ehlers and Shah formulas were more close to preoperative IOP for both surgeries, with IOP variation approximately 1. Previous studies have found that IOPcc and Pentacam-Ehlers were consistent before and after LASIK 13 because only Pentacam Ehlers was available in that version of the machine. The corrected IOP can eliminate the influence of CCT. In this study, the Ehlers significantly increased at 6 months postoperatively, which may be related to the corrected coefficients and formula. It needs further investigation. A comparison of DIOP per removed or ablated tissue showed that DIOPg and DIOPcc per removed tissue in SMILE was lower than with FS-LASIK. DIOPg had a moderate correlation with DCRF (Table 3). Reasons for this change may be the better preservation of corneal integrity and corneal biomechanics after SMILE. 26 A strong positive linear correlation was found between DIOP and preoperative IOP, which was consistent with Schallhorn et al., 32 being the strongest predictor of postoperative IOP. In the FS-LASIK group, DIOP had more influencing factors and correlated with CH and CRF. Regarding DCCT, the correlation coefficient was smaller than the corneal biomechanic parameter CRF. Similarly, Liu et al. 29 reported that corneal biomechanics may contribute more than corneal thickness or curvature to IOP change, with controversy regarding how much DIOP can be explained by the DCCT. 33 From the available data, it was possible to construct models for IOP change after SMILE and FS-LASIK. These models cannot evaluate all of the variance after refractive surgery. The best-fit model for SMILE and FS-LASIK can explain 50.5% and 55.2% variance, respectively. In both models, preoperative IOP was still the main predictor of DIOP. Furthermore, postoperative CH, CRF, and Kf also enrolled in the equation, which was a new finding and a reminder of the important role of corneal biomechanics in IOP changes. In addition, NCT was a simple and safe device for routine IOP measurements. Previous data have showed that NCT can produce accurate IOP that is comparable to a Goldmann tonometer, 34,35 which was the gold standard, allowing these models to be useful in evaluating future IOP changes. The calculation of DIOP needs preoperative IOP and postoperative corneal biomechanics, which may need more comprehensive examinations. Previous studies have constructed statistical models to predict postoperative IOP after LASIK. Cheng et al. 4 used NCT to measure IOP after LASIK in 123 eyes and gave a model involving postoperative CCT, postoperative corneal curvature, and AD. That study did not consider the corneal biomechanics, which were the main influencing factors. Schallhorn et al. 32 also used NCT to measure IOP after LASIK in a large sample investigation, and the best-fit model, including manifest refraction spherical equivalent and preoperative IOP, can explain 45% variance. In that study, although the large sample was important, it only considered CCT, corneal curvature, and manifest refraction spherical equivalent while ignoring corneal biomechanics. The models in this study may be valuable when evaluating IOP after SMILE if the influence of corneal biomechanics is considered. Although new influencing factors have been added to the model to evaluate the real IOP, this study needs more samples for further study. Other IOP measurement devices need be investigated in future, such as the Goldmann tonometer, which was a gold standard for IOP measurements of a normal cornea. Some studies have showed that the Goldmann tonometer was no more accurate and could lower the IOP after PRK (photorefractive keratectomy), 15 LASEK, 10 and LASEK (laser-assisted subepithelial keratectomy), 36 because it can be affected by the corneal thickness. However, the Goldmann tonometer measurement still needs to be investigated in the further research. In summary, IOP measurement underestimation after SMILE and FS-LASIK was related to corneal biomechanics as well as to preoperative IOP and Kf. IOP after SMILE seemed to remain more stable than FS-LASIK. Accordingly, the Ehlers and Shah formulas were closer to the preoperative values, with IOP variation approximately 1 at 6 months postoperatively. The best-fit models for IOP change may be useful to evaluate the long-term postoperative IOP after SMILE and FS-LASIK. Further investigations on accurate IOP measurements are required. Acknowledgments Supported by the National Natural Science Foundation of China (Grant ) and Tianjin Research Program of Application Foundation and Advanced Technology (14JCZDJC35900). The authors alone are responsible for the content and writing of the paper. Disclosure: H. Li, None; Y. Wang, None; R. Dou, None; P. Wei, None; J. Zhang, None; W. Zhao, None; L. Li, None References 1. Lee JK, Chuck RS, Park CY. Femtosecond laser refractive surgery: small-incision lenticule extraction vs. femtosecond laser-assisted LASIK. Curr Opin Ophthalmol. 2015;26: Vestergaard A, Ivarsen AR, Asp S, et al. Small-incision lenticule extraction for moderate to high myopia: predictability, safety, and patient satisfaction. J Cataract Refract Surg. 2012;38: Reinstein DZ, Carp GI, Archer TJ, et al. Outcomes of small incision lenticule extraction (SMILE) in low myopia. J Refract Surg. 2014;30: Cheng AC, Fan D, Tang E, et al. Effect of corneal curvature and corneal thickness on the assessment of intraocular pressure using noncontact tonometry in patients after myopic LASIK surgery. Cornea. 2006;25: Marcus MW, de Vries MM, Junoy Montolio FG, et al. Myopia as a risk factor for open-angle glaucoma: a systematic review and meta-analysis. Ophthalmology. 2011;118: Tomi T, Nicula C, Nicula D. Postoperative complications of refractive surgery, Lasik technique. Oftalmologia. 2003;58: The Advanced Glaucoma Intervention Study. The relationship between control of intraocular pressure and visual field deterioration. Am J Ophthalmol. 2000;130: Chatterjee A, Shah S, Bessant DA, et al. Reduction in intraocular pressure after excimer laser photorefractive keratectomy correlation with pretreatment myopia. Ophthalmology. 1997;104: Sadigh AL, Fouladi RF, Hashemi H, et al. A comparison between Goldmann applanation tonometry and dynamic contour tonometry after photorefractive keratectomy. Graefes Arch Clin Exp Ophthalmol. 2013;251: Johannesson G, Hallberg P, Eklund A, et al. Change in intraocular pressure measurement 2 years after myopic laserassisted subepithelial keratectomy. J Cataract Refract Surg. 2012;38: Han KE, Kim H, Kim NR, et al. Comparison of intraocular pressures after myopic laser-assisted subepithelial keratectomy: Tonometry-pachymetry, Goldmann applanation tonometry, dynamic contour tonometry, and noncontact tonometry. J Cataract Refract Surg. 2013;39: Kaufmann C, Bachmann LM, Thiel MA. Intraocular pressure measurements using dynamic contour tonometry after laser in situ keratomileusis. Invest Ophthalmol Vis Sci. 2003;44:

7 Intraocular Pressure Changes After SMILE and FS-LASIK IOVS j August 2016 j Vol. 57 j No. 10 j Shousha SM, Abo Steit MA, Hosny MH, et al. Comparison of different intraocular pressure measurement techniques in normal eyes, post surface and post lamellar refractive surgery. Clin Ophthalmol. 2013;7: Shemesh G, Soiberman U, Kurtz S. Intraocular pressure measurements with Goldmann applanation tonometry and dynamic contour tonometry in eyes after IntraLASIK or LASEK. Clin Ophthalmol. 2012;6: Garzozi HJ, Chung HS, Lang Y, et al. Intraocular pressure and photorefractive keratectomy: a comparison of three different tonometers. Cornea. 2001;20: Roberts CJ. Concepts and misconceptions in corneal biomechanics. J Refract Surg. 2014;40: Lam A, Chen D, Chiu R, et al. Comparison of IOP measurements between ORA and GAT in normal Chinese. Optom Vis Sci. 2007;84: Pepose JS, Feigenbaum SK, Qazi MA, et al. Changes in corneal biomechancis and intraocular pressure following LASIK using static, dynamic and noncontact tonometry. Am J Ophthalmol. 2007;143: Dou R, Wang Y, Xu L, et al. Comparison of corneal biomechanical characteristics after surface ablation refractive surgery and novel lamellar refractive surgery. Cornea. 2015; 34: Yilmaz I, Altan C, Aygit ED, et al. Comparison of three methods of tonometry in normal subjects: Goldmann applanation tonometer, non-contact airpuff tonometer, and Tono-Pen XL. Clin Ophthalmol. 2014;8: Ehlers N, Bramsen T, Sperling S. Applanation tomometry and central corneal thickness. Acta Ophthalmol. 1975;53: Shah S, Chatterjee A, Mathai M, et al. Relationship between corneal thickness and measured intraocular pressure in a general ophthalmology clinic. Ophthalmology. 1999;106: Kohlhaas M, Boehm AG, Spoerl E, et al. Effect of central corneal thickness, corneal curvature, and axial length on applanation tomometry. Arch Ophthalmol. 2006;124: Kohlhaas M, Spoerl E, Boehm AG, et al. A correction formula for the real intraocular pressure after LASIK for the correction of myopic astigmatism. J Refract Surg. 2006;22: Orssengo GJ, Pye DC. Determination of the true intraocular pressure and modulus of elasticity of the human cornea in vivo. Bull Math Biol. 1999;61: Wu D, Wang Y, Zhang L, et al. Corneal biomechanical effects: small-incision lenticule extraction versus femtosecond laserassisted laser in situ keratomileusis. J Cataract Refract Surg. 2014;40: Siganos DS, Papastergion GI, Moedas C. Assessment of the pascal dynamic contour tonometer in monitoring intraocular pressure in unoperated eyes and eyes after LASIK. J Cataract Refract Surg. 2004;30: Cacho I, Sanchez-Naves J, Batres L, et al. Comparison of Intraocular pressure before and after laser in situ keratomileusis refractive surgery measured with Perkins tonometry noncontact tonometry, and transpalpebral tonometry. J Ophthalmol. 2015;2015: Liu J, Roberts CJ. Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis. J Cataract Refract Surg. 2005;31: Armaly MF. Statistical attributes of the steroid hypertensive response in the clinically normal eye: the demonstration at three levels of response. Invest Ophthalmol. l965;4: Dong Z, Zhou X, Wu J, et al. Small incision lenticule extraction (SMILE) and femtosecond laser LASIK: comparison of corneal wound healing and inflammation. Br J Ophthalmol. 2014;98: Schallhorn JM, Schallhorn SC, Ou Y. Factors that influence intraocular pressure changes after myopic and hyperopic LASIK and photorefractive keratectomy: a large population study. Ophthalmology. 2015;122: Kotecha A. What biomechanical properties of the cornea are relevant for the clinician? Surv Ophthalmol. 2007;52(suppl 2): S109 S Jorge J, Diaz-Rey JA, Gonzalez-Meijome JM, et al. Clinical performance of the Reichert AT 550: a new non-contact tonometer. Ophthalmic Physiol Opt. 2002;22: Cho P, Lui T. Comparison of the performance of the Nidek NT noncontact tonometer with the Keeler Pulsair 2000 and the Goldmann applanation tonometer. Optom Vis Sci. 1997; 74: Kirwan C, O Keefe M. Measurement of intraocular pressure in LASIK and LASEK patients using the Reichert Ocular Response Analyzer and Goldmann applanation tonometry. J Refract Surg. 2008;24:

December 2016, Volume: 8, Issue: 12, Pages: , DOI:

December 2016, Volume: 8, Issue: 12, Pages: , DOI: Electronic Physician (ISSN: 2008-5842) http://www.ephysician.ir December 2016, Volume: 8, Issue: 12, Pages: 3429-3433, DOI: http://dx.doi.org/10.19082/3429 Refinement of Intraocular Pressure Measurements

More information

Jose M. Martinez-de-la-Casa, Julian Garcia-Feijoo, Ana Fernandez-Vidal, Carmen Mendez-Hernandez, and Julian Garcia-Sanchez METHODS

Jose M. Martinez-de-la-Casa, Julian Garcia-Feijoo, Ana Fernandez-Vidal, Carmen Mendez-Hernandez, and Julian Garcia-Sanchez METHODS Ocular Response Analyzer versus Goldmann Applanation Tonometry for Intraocular Pressure Measurements Jose M. Martinez-de-la-Casa, Julian Garcia-Feijoo, Ana Fernandez-Vidal, Carmen Mendez-Hernandez, and

More information

Wenjing Wu and Yan Wang. 1. Introduction. 2. Materials and Methods

Wenjing Wu and Yan Wang. 1. Introduction. 2. Materials and Methods Journal of Ophthalmology Volume 2015, Article ID 758196, 10 pages http://dx.doi.org/10.1155/2015/758196 Research Article The Correlation Analysis between Corneal Biomechanical Properties and the Surgically

More information

Original Article Comparison of different femtosecond laser refractive surgeries on higher-order aberrations

Original Article Comparison of different femtosecond laser refractive surgeries on higher-order aberrations Int J Clin Exp Med 2016;9(11):22375-22380 www.ijcem.com /ISSN:1940-5901/IJCEM0034556 Original Article Comparison of different femtosecond laser refractive surgeries on higher-order aberrations Xinli Zhang

More information

Comparison between Pascal dynamic contour tonometer and Goldmann applanation tonometer after different types of refractive surgery

Comparison between Pascal dynamic contour tonometer and Goldmann applanation tonometer after different types of refractive surgery DOI 10.1007/s00417-010-1431-9 REFRACTIVE SURGERY Comparison between Pascal dynamic contour tonometer and Goldmann applanation tonometer after different types of refractive surgery Antonios P. Aristeidou

More information

Yang Shen 1,2, Xiangjian Su 3, Xiu Liu 3, Huamao Miao 1,2, Xuejun Fang 3* and Xingtao Zhou 1,2*

Yang Shen 1,2, Xiangjian Su 3, Xiu Liu 3, Huamao Miao 1,2, Xuejun Fang 3* and Xingtao Zhou 1,2* Shen et al. BMC Ophthalmology (2016) 16:205 DOI 10.1186/s12886-016-0381-3 RESEARCH ARTICLE Changes in intraocular pressure values measured with noncontact tonometer (NCT), ocular response analyzer (ORA)

More information

INTRODUCTION S. HERDENER, D. HAFIZOVIC, M. PACHE, S. LAUTEBACH, J. FUNK. University Eye Hospital, Freiburg - Germany

INTRODUCTION S. HERDENER, D. HAFIZOVIC, M. PACHE, S. LAUTEBACH, J. FUNK. University Eye Hospital, Freiburg - Germany European Journal of Ophthalmology / Vol. 18 no. 1, 2008 / pp. 39-43 Is the PASCAL -Tonometer suitable for measuring intraocular pressure in clinical routine? Long- and short-term reproducibility of dynamic

More information

CLINICAL SCIENCES. Effect of Central Corneal Thickness, Corneal Curvature, and Axial Length on Applanation Tonometry

CLINICAL SCIENCES. Effect of Central Corneal Thickness, Corneal Curvature, and Axial Length on Applanation Tonometry CLINICAL SCIENCES Effect of Central Corneal Thickness, Corneal Curvature, and Axial Length on Applanation Tonometry Markus Kohlhaas, MD; Andreas G. Boehm, MD; Eberhard Spoerl, PhD; Antje Pürsten, Dipl-Ing

More information

The Egyptian Journal of Hospital Medicine (October 2018) Vol. 73 (9), Page

The Egyptian Journal of Hospital Medicine (October 2018) Vol. 73 (9), Page The Egyptian Journal of Hospital Medicine (October 2018) Vol. 73 (9), Page 7574-7579 Biomechanical Corneal Changes Post LASIK with Mechanical Microkeratome Flap versus Femtosecond Flap Department of Ophthalmology,

More information

Effects of Intracorneal Ring Segment on Corneal Biomechanics in Keratoconic Eyes. Abstract

Effects of Intracorneal Ring Segment on Corneal Biomechanics in Keratoconic Eyes. Abstract Effects of Intracorneal Ring Segment on Corneal Biomechanics in Keratoconic Eyes Javad Amoozadeh, MD 1 Nima Mirzaee Rad, MD 2 Amir Houshang Beheshtnejad, MD 3 Ahmad Kheirkhah, MD 1 Hassan Hashemi, MD 4,5

More information

Dina H. Erickson, O.D., a Denise Goodwin, O.D., a Michael Rollins, O.D., b Amber Belaustegui, O.D., c and Chad Anderson a

Dina H. Erickson, O.D., a Denise Goodwin, O.D., a Michael Rollins, O.D., b Amber Belaustegui, O.D., c and Chad Anderson a Optometry (2009) 80, 169-174 Comparison of dynamic contour tonometry and Goldmann applanation tonometry and their relationship to corneal properties, refractive error, and ocular pulse amplitude Dina H.

More information

Comparison of Corneal Shape Changes and Aberrations Induced By FS-LASIK and SMILE for Myopia

Comparison of Corneal Shape Changes and Aberrations Induced By FS-LASIK and SMILE for Myopia ORIGINAL ARTICLE Comparison of Corneal Shape Changes and Aberrations Induced By FS-LASIK and SMILE for Myopia Anders Gyldenkerne, MS; Anders Ivarsen, MD, PhD; Jesper Ø. Hjortdal, MD, PhD ABSTRACT PURPOSE:

More information

Cataract Surgery in the Patient with a History of LASIK or PRK

Cataract Surgery in the Patient with a History of LASIK or PRK Cataract Surgery in the Patient with a History of LASIK or PRK #56996-RS April 2018 Sebastian Lesniak, MD Matossian Eye Associates None Disclosures Bio Matossian Eye Associates, Hopewell NJ, 7/2015 Present

More information

NIIOS. Cornea Specialist, Melles Cornea Clinic, NIIOS, Rotterdam, the Netherlands Naval Hospital, Athens, Greece VASILIS S.

NIIOS. Cornea Specialist, Melles Cornea Clinic, NIIOS, Rotterdam, the Netherlands Naval Hospital, Athens, Greece VASILIS S. Cornea Specialist, Melles Cornea Clinic, NIIOS, Rotterdam, the Netherlands Naval Hospital, Athens, Greece Goldman applanation tonometry is still the gold standard for measuring IOP, but its accuracy is

More information

White Paper. Topography-Guided Laser Assisted In-Situ Keratomileusis vs Small- Incision Lenticule Extraction Refractive Surgery

White Paper. Topography-Guided Laser Assisted In-Situ Keratomileusis vs Small- Incision Lenticule Extraction Refractive Surgery White Paper Topography-Guided Laser Assisted In-Situ Keratomileusis vs Small- Incision Lenticule Extraction Refractive Surgery A Summary of Clinical Outcomes Andrea Petznick, Diplom-AO (FH), PhD Alcon

More information

Author s Affiliation. Original Article. Visual outcomes after LASIK (laser-assisted in-situ keratomileusis) for various refractive errors.

Author s Affiliation. Original Article. Visual outcomes after LASIK (laser-assisted in-situ keratomileusis) for various refractive errors. Original Article Visual outcomes after LASIK (laser-assisted in-situ keratomileusis) for various refractive errors. Author s Affiliation Sobia Tufail Imran Ahmad Asad Aslam Khan Correspondence Author:

More information

One-year outcomes of small-incision lenticule extraction (SMILE): mild to moderate myopia vs. high myopia

One-year outcomes of small-incision lenticule extraction (SMILE): mild to moderate myopia vs. high myopia Kim et al. BMC Ophthalmology (2015) 15:59 DOI 10.1186/s12886-015-0051-x RESEARCH ARTICLE Open Access One-year outcomes of small-incision lenticule extraction (SMILE): mild to moderate myopia vs. high myopia

More information

Sheldon Herzig MD, FRCSC Herzig Eye Institute Toronto, Ontario

Sheldon Herzig MD, FRCSC Herzig Eye Institute Toronto, Ontario Sheldon Herzig MD, FRCSC Herzig Eye Institute Toronto, Ontario Clinical Visual quality Improved safety Financial Increase LVC volume Personal Peer-reviewed papers Conversations with users Observe experienced

More information

White Paper. Topography-Guided Laser Assisted In-Situ Keratomileusis vs Small- Incision Lenticule Extraction Refractive Surgery

White Paper. Topography-Guided Laser Assisted In-Situ Keratomileusis vs Small- Incision Lenticule Extraction Refractive Surgery White Paper Topography-Guided Laser Assisted In-Situ Keratomileusis vs Small- Incision Lenticule Extraction Refractive Surgery A Summary of Clinical Outcomes Andrea Petznick, Diplom-AO (FH), PhD Alcon

More information

A pilot study: LASEK with the Triple-A profile of a MEL 90 for mild and moderate myopia

A pilot study: LASEK with the Triple-A profile of a MEL 90 for mild and moderate myopia Chen et al. BMC Ophthalmology (2017) 17:98 DOI 10.1186/s12886-017-0493-4 RESEARCH ARTICLE A pilot study: LASEK with the Triple-A profile of a MEL 90 for mild and moderate myopia Yingjun Chen 1, Dong Yang

More information

Comparison of Intraocular Pressure Measurements by the Ocular Response Analyzer and Goldmann Applanation Tonometer after Penetrating Keratoplasty

Comparison of Intraocular Pressure Measurements by the Ocular Response Analyzer and Goldmann Applanation Tonometer after Penetrating Keratoplasty Comparison of Intraocular Pressure Measurements by the Ocular Response Analyzer and Goldmann Applanation Tonometer after Penetrating Keratoplasty in Keratoconic Patients Sepehr Feizi, MD 1 Mohammad Pakravan,

More information

Flap characteristics, predictability, and safety of the Ziemer FEMTO LDV femtosecond laser with the disposable suction ring for LASIK

Flap characteristics, predictability, and safety of the Ziemer FEMTO LDV femtosecond laser with the disposable suction ring for LASIK (2014) 28, 66 71 & 2014 Macmillan Publishers Limited All rights reserved 0950-222X/14 www.nature.com/eye CLINICAL STUDY Flap characteristics, predictability, and safety of the Ziemer FEMTO LDV femtosecond

More information

Evaluation of the Effect of Diabetes Mellitus on Corneal Biomechanics

Evaluation of the Effect of Diabetes Mellitus on Corneal Biomechanics The Egyptian Journal of Hospital Medicine (January 2019) Vol. 74 (4), Page 782-788 Abd Elmagid Mohamed Tag Eldin, Abdulmoez Haddad Ahmed, Amr Khalil Abdelmonem* Ophthalmology department, Faculty of Medicine,

More information

The changes in corneal biomechanical parameters after phototherapeutic keratectomy in eyes with granular corneal dystrophy

The changes in corneal biomechanical parameters after phototherapeutic keratectomy in eyes with granular corneal dystrophy (2009) 23, 1790 179 & 2009 Macmillan Publishers Limited All rights reserved 090-222X/09 $32.00 www.nature.com/eye CLINICAL STUDY The changes in corneal biomechanical parameters after phototherapeutic keratectomy

More information

Laser in situ keratomileusis (LASIK) has proven to be

Laser in situ keratomileusis (LASIK) has proven to be Autorefractometry after laser in situ keratomileusis Dimitrios S. Siganos, MD, PhD, Corina Popescu, MD, Nikolaos Bessis, DOpt, Georgios Papastergiou, MD Purpose: To correlate cycloplegic subjective refraction

More information

For approximately two decades photorefractive keratectomy. Seven-Year Changes in Corneal Power and Aberrations after PRK or LASIK.

For approximately two decades photorefractive keratectomy. Seven-Year Changes in Corneal Power and Aberrations after PRK or LASIK. Cornea Seven-Year Changes in Corneal Power and Aberrations after PRK or LASIK Anders Ivarsen and Jesper Hjortdal PURPOSE. To examine long-term changes in corneal power and aberrations in myopic patients

More information

Visual and Refractive Outcomes of Small-Incision Lenticule Extraction for the Correction of Myopia: One-Year Follow- Up. For peer review only

Visual and Refractive Outcomes of Small-Incision Lenticule Extraction for the Correction of Myopia: One-Year Follow- Up. For peer review only Visual and Refractive Outcomes of Small-Incision Lenticule Extraction for the Correction of Myopia: One-Year Follow- Up. Journal: BMJ Open Manuscript ID: bmjopen--00 Article Type: Research Date Submitted

More information

In recent years, more and more studies have focused on. Characteristics of Straylight in Normal Young Myopic Eyes and Changes before and after LASIK

In recent years, more and more studies have focused on. Characteristics of Straylight in Normal Young Myopic Eyes and Changes before and after LASIK Cornea Characteristics of Straylight in Normal Young Myopic Eyes and Changes before and after LASIK Jing Li and Yan Wang PURPOSE. To investigate the characteristics of straylight and relevant factors in

More information

An Ultra-High-Speed Scheimpflug Camera for Evaluation of Corneal Deformation Response and Its Impact on IOP Measurement

An Ultra-High-Speed Scheimpflug Camera for Evaluation of Corneal Deformation Response and Its Impact on IOP Measurement Glaucoma An Ultra-High-Speed Scheimpflug Camera for Evaluation of Corneal Deformation Response and Its Impact on IOP Measurement Christopher Kai-Shun Leung, 1 Cong Ye, 1 and Robert N. Weinreb 2 1 Department

More information

Policy #: 354 Latest Review Date: July 2011

Policy #: 354 Latest Review Date: July 2011 Name of Policy: Corneal Hysteresis Policy #: 354 Latest Review Date: July 2011 Category: Medicine Policy Grade: Active Policy but no longer scheduled for regular literature reviews and updates. Background/Definitions:

More information

Four-year Postoperative Results of the US ALLEGRETTO WAVE Clinical Trial for the Treatment of Hyperopia

Four-year Postoperative Results of the US ALLEGRETTO WAVE Clinical Trial for the Treatment of Hyperopia Four-year Postoperative Results of the US ALLEGRETTO WAVE Clinical Trial for the Treatment of Hyperopia Guy M. Kezirian, MD, FACS; Charles R. Moore, MD, FICS; Karl G. Stonecipher, MD; SurgiVision Consultants

More information

Comparison of IOP measurement by ocular response analyzer, dynamic contour, Goldmann applanation, and noncontact tonometry

Comparison of IOP measurement by ocular response analyzer, dynamic contour, Goldmann applanation, and noncontact tonometry European Journal of Ophthalmology / Vol. 19 no. 6, 2009 / pp. 936-941 Comparison of IOP measurement by ocular response analyzer, dynamic contour, Goldmann applanation, and noncontact tonometry BANU ONCEL,

More information

Nature and Science 2017;15(11) Mohamed Elmoddather. MD

Nature and Science 2017;15(11)   Mohamed Elmoddather. MD Outcome of PRK in Management of Post LISIK Residual Myopia and Myopic Astigmatism Mohamed Elmoddather. MD Ophthalmology Faculty of Medicine, Al-Azhar University, Assuit, Egypt shahdmsaleh@hotmail.com Abstract:

More information

Recent concerns regarding the depth of tissue ablation with

Recent concerns regarding the depth of tissue ablation with Volume Estimation of Excimer Laser Tissue Ablation for Correction of Spherical Myopia and Hyperopia Damien Gatinel, 1 Thanh Hoang-Xuan, 1 and Dimitri T. Azar 1,2 PURPOSE. To determine the theoretical volumes

More information

Number 80. Laser Eye Surgery in Myopia. Date of decision October 2017 Date of review October 2020 GUIDANCE

Number 80. Laser Eye Surgery in Myopia. Date of decision October 2017 Date of review October 2020 GUIDANCE Excluded: Procedure not routinely funded Bedfordshire, Hertfordshire, West Essex, Luton and Milton Keynes Priorities Forum statement - adapted for Bedfordshire CCG Number 80 Subject Date of decision October

More information

2/7/18. Disclosures: Laser K s: Keratectomy to Keratomileusis with a SMILE. Who Patients Are Listening to

2/7/18. Disclosures: Laser K s: Keratectomy to Keratomileusis with a SMILE. Who Patients Are Listening to Disclosures: Laser K s: Keratectomy to Keratomileusis with a SMILE Glaukos Equinox Alcon Mitch Ibach OD, FAAO Vance Thompson Vision Who Patients Are Listening to Optometrist 36% People who've had surgery

More information

Peretyagin O.A., Cand. Med. Sc., Ass. Prof.; Dmitriev S.K., Dr. Med. Sc., Prof.; Lazar Yu.M., Cand. Med. Sc.; Tatarina Yu.A., Junior Research Fellow

Peretyagin O.A., Cand. Med. Sc., Ass. Prof.; Dmitriev S.K., Dr. Med. Sc., Prof.; Lazar Yu.M., Cand. Med. Sc.; Tatarina Yu.A., Junior Research Fellow Changes in corneoscleral rigidity and corneal thickness at various target intraocular pressures in patients with stabilized primary open-angle glaucoma Peretyagin O.A., Cand. Med. Sc., Ass. Prof.; Dmitriev

More information

펨토초레이저와미세각막절삭기를이용한근시교정수술에서임상성적비교

펨토초레이저와미세각막절삭기를이용한근시교정수술에서임상성적비교 펨토초레이저와미세각막절삭기를이용한근시교정수술에서임상성적비교 4 Table. Summary of data about patient who had LASIK operation using second laser and keratome Age (years) Male:Female (eyes) Pre-op. IOP (mmhg) Pre-op SE * (D) Pre-op

More information

Comparison between Pentacam HR and Orbscan II after Hyperopic Photorefractive Keratectomy

Comparison between Pentacam HR and Orbscan II after Hyperopic Photorefractive Keratectomy Original Article Comparison between Pentacam HR and Orbscan II after Hyperopic Photorefractive Keratectomy Mahmoud Jabbarvand 1, MD; Farshad Askarizadeh 2, PhD; Mohamad Reza Sedaghat 3, MD Hadi Ghadimi

More information

Introduction. Anders Vestergaard, 1,2 Anders Ivarsen, 1 Sven Asp 1 and Jesper Ø. Hjortdal 1. Acta Ophthalmologica 2013

Introduction. Anders Vestergaard, 1,2 Anders Ivarsen, 1 Sven Asp 1 and Jesper Ø. Hjortdal 1. Acta Ophthalmologica 2013 Femtosecond (FS) laser vision correction procedure for moderate to high myopia: a prospective study of ReLEx Ò flex and comparison with a retrospective study of FS-laser in situ keratomileusis Anders Vestergaard,

More information

Cataract Surgery in Patients with a Previous History of KAMRA Inlay Implantation: A Case Series

Cataract Surgery in Patients with a Previous History of KAMRA Inlay Implantation: A Case Series Ophthalmol Ther (2017) 6:207 213 DOI 10.1007/s40123-017-0088-4 CASE SERIES Cataract Surgery in Patients with a Previous History of KAMRA Inlay Implantation: A Case Series Majid Moshirfar. Tyler S. Quist.

More information

Enhancement of femtosecond lenticule extraction for visual symptomatic eye after myopia correction

Enhancement of femtosecond lenticule extraction for visual symptomatic eye after myopia correction Zhao et al. BMC Ophthalmology 2014, 14:68 CASE REPORT Open Access Enhancement of femtosecond lenticule extraction for visual symptomatic eye after myopia correction Jing Zhao, Peijun Yao, Zhi Chen, Meiyan

More information

MEDICAL POLICY SUBJECT: CORNEAL ULTRASOUND PACHYMETRY. POLICY NUMBER: CATEGORY: Technology Assessment

MEDICAL POLICY SUBJECT: CORNEAL ULTRASOUND PACHYMETRY. POLICY NUMBER: CATEGORY: Technology Assessment MEDICAL POLICY SUBJECT: CORNEAL ULTRASOUND,, PAGE: 1 OF: 5 If a product excludes coverage for a service, it is not covered, and medical policy criteria do not apply. If a commercial product, including

More information

Evaluation of The Accuracy of Sub Bowman s Keratomileusis (SBK) Microkeratome in Flap Creation during Lasik Surgery

Evaluation of The Accuracy of Sub Bowman s Keratomileusis (SBK) Microkeratome in Flap Creation during Lasik Surgery The Egyptian Journal of Hospital Medicine (April 2018) Vol. 71 (3), Page 2636-2642 Evaluation of The Accuracy of Sub Bowman s Keratomileusis (SBK) Microkeratome in Flap Creation during Lasik Surgery Hager

More information

Predicting Refractive Outcome of Small Incision Lenticule Extraction for Myopia Using Corneal Properties

Predicting Refractive Outcome of Small Incision Lenticule Extraction for Myopia Using Corneal Properties Article https://doi.org/10.1167/tvst.7.5.11 Predicting Refractive Outcome of Small Incision Lenticule Extraction for Myopia Using Corneal Properties Mengyu Wang 1, *, Yaohua Zhang 2, *,WenjingWu 2,3, Joshua

More information

Laser in situ keratomileusis (LASIK) has

Laser in situ keratomileusis (LASIK) has Changes in Intraocular Pressure After Laser in situ Keratomileusis Khaled M. Rashad, MD; Ahmed A. Bahnassy, MSc, PhD ABSTRACT PURPOSE: To evaluate changes in intraocular pressure (IOP) measurements by

More information

Management of Unpredictable Post-PRK Corneal Ectasia with Intacs Implantation

Management of Unpredictable Post-PRK Corneal Ectasia with Intacs Implantation Management of Unpredictable Post-PRK Corneal Ectasia with Intacs Implantation Mohammad Naser Hashemian, MD 1 Mahdi AliZadeh, MD 2 Hassan Hashemi, MD 1,3 Firoozeh Rahimi, MD 4 Abstract Purpose: To present

More information

Keratoconus Clinic. Optometric Co-management Opportunities

Keratoconus Clinic. Optometric Co-management Opportunities Keratoconus Clinic Optometric Co-management Opportunities The Bochner Eye Institute established the first Keratoconus Clinic in Canada in 2008. The consultation and advanced imaging are OHIP covered. All

More information

Deep anterior lamellar keratoplasty (DALK) is considered

Deep anterior lamellar keratoplasty (DALK) is considered Cornea Comparison of the Ocular Response Analyzer and the Goldmann Applanation Tonometer for Measuring Intraocular Pressure after Deep Anterior Lamellar Keratoplasty Sepehr Feizi, 1,2 Ali Hashemloo, 1,2

More information

Research Article Effect of Cap-Lenticule Diameter Difference on the Visual Outcome and Higher-Order Aberrations in SMILE: 0.4mm versus 1.

Research Article Effect of Cap-Lenticule Diameter Difference on the Visual Outcome and Higher-Order Aberrations in SMILE: 0.4mm versus 1. Hindawi Ophthalmology Volume 2017, Article ID 8259546, 7 pages https://doi.org/10.1155/2017/8259546 Research Article Effect of Cap-Lenticule Diameter Difference on the Visual Outcome and Higher-Order Aberrations

More information

Our experience with Athens protocol - simultaneous topo-guided photorefractive keratectomy followed by corneal collagen cross linking for keratoconus

Our experience with Athens protocol - simultaneous topo-guided photorefractive keratectomy followed by corneal collagen cross linking for keratoconus International Journal of Research in Medical Sciences Shah S et al. Int J Res Med Sci. 2016 Jul;4(7):2639-2644 www.msjonline.org pissn 2320-6071 eissn 2320-6012 Research Article DOI: http://dx.doi.org/10.18203/2320-6012.ijrms20161924

More information

Central and Peripheral Changes in Anterior Corneal Topography after Orthokeratology and Laser in situ Keratomileusis

Central and Peripheral Changes in Anterior Corneal Topography after Orthokeratology and Laser in situ Keratomileusis Central and Peripheral Changes in Anterior Corneal Topography after Orthokeratology and Laser in situ Keratomileusis Han-Yin Sun 1, 2, 3, Hsiu-Wan Yang 4, I-Tsung Wu 4, Jung-Kai Tseng 2, 3 1, 5* and Shun-Fa

More information

Wavefront-optimized Versus Wavefrontguided LASIK for Myopic Astigmatism With the ALLEGRETTO WAVE: Three-month Results of a Prospective FDA Trial

Wavefront-optimized Versus Wavefrontguided LASIK for Myopic Astigmatism With the ALLEGRETTO WAVE: Three-month Results of a Prospective FDA Trial Wavefront-optimized Versus Wavefrontguided LASIK for Myopic Astigmatism With the ALLEGRETTO WAVE: Three-month Results of a Prospective FDA Trial Karl G. Stonecipher, MD; Guy M. Kezirian, MD, FACS ABSTRACT

More information

Contoura TM Vision Correction

Contoura TM Vision Correction Contoura TM Vision Correction Fernando Faria Correia, Financial Disclosures: Alcon/Wavelight Cairo (Egypt) 26/01/2018 Topography-guided ablations Topography guided ablations Evolution from complicated

More information

Make a more confident glaucoma risk assessment with Corneal Hysteresis, a superior predictor of glaucoma progression.

Make a more confident glaucoma risk assessment with Corneal Hysteresis, a superior predictor of glaucoma progression. Make a more confident glaucoma risk assessment with Corneal Hysteresis, a superior predictor of glaucoma progression. Advancing Eye Care. American Innovation. Reichert Ocular Response Analyzer G3. Make

More information

Laser-assisted in situ keratomileusis (LASIK) is the most

Laser-assisted in situ keratomileusis (LASIK) is the most CLINICAL SCIENCE Visual Outcomes After SMILE, LASEK, and LASEK Combined With Corneal Collagen Cross-Linking for High Myopic Correction Sangyoon Hyun, MD,* Seongjun Lee, MD, and Jae-hyung Kim, MD* Purpose:

More information

LASIK for 6.00 to D of Myopia With up to 3.00 D of Cylinder Using the ALLEGRETTO WAVE: 3- and 6-month Results With the 200- and 400-Hz Platforms

LASIK for 6.00 to D of Myopia With up to 3.00 D of Cylinder Using the ALLEGRETTO WAVE: 3- and 6-month Results With the 200- and 400-Hz Platforms LASIK for 6.00 to 12.00 D of Myopia With up to 3.00 D of Cylinder Using the ALLEGRETTO WAVE: 3- and 6-month Results With the 200- and 400-Hz Platforms Karl G. Stonecipher, MD; Guy M. Kezirian, MD; Megan

More information

Corneal Hysteresis, Resistance Factor, Topography, and Pachymetry After Corneal Lamellar Flap

Corneal Hysteresis, Resistance Factor, Topography, and Pachymetry After Corneal Lamellar Flap Corneal Hysteresis, Resistance Factor, Topography, and Pachymetry After Corneal Lamellar Flap Damien Gatinel, MD, PhD; Slim Chaabouni, MD; Pierre-Alexandre Adam, MD; Jacques Munck, OD; Michel Puech, MD;

More information

Comparative Studies on Femto-LASIK

Comparative Studies on Femto-LASIK Comparative Studies on Femto-LASIK Assoc Prof Jod Mehta P Royalty: Network Medical Products D Research Funds: Carl Zeiss Meditec Assoc Prof Jod S Mehta BSc.(Hons), MBBS, FRCOphth, FRCS (Ed) Consultant

More information

Correlation between presence of primary irisand cilliary body cysts and intraocular pressure

Correlation between presence of primary irisand cilliary body cysts and intraocular pressure European Review for Medical and Pharmacological Sciences 2017; 21: 3985-3989 Correlation between presence of primary irisand cilliary body cysts and intraocular pressure R. ZHU, L. CHENG, D.-M. WANG Institute

More information

Glaucoma is the leading cause of irreversible blindness in

Glaucoma is the leading cause of irreversible blindness in CLINICAL SCIENCE Determinants of Postoperative Corneal Edema and Impact on Goldmann Intraocular Pressure Yuqiang Huang, MBBS,* Mingzhi Zhang, MD,* Chukai Huang, MBBS,* Bin Chen, PhD,* Dennis S. C. Lam,

More information

Research Article Effect of Mitomycin C on Myopic versus Astigmatic Photorefractive Keratectomy

Research Article Effect of Mitomycin C on Myopic versus Astigmatic Photorefractive Keratectomy Hindawi Ophthalmology Volume 2017, Article ID 2841408, 5 pages https://doi.org/10.1155/2017/2841408 Research Article Effect of Mitomycin C on Myopic versus Astigmatic Photorefractive Keratectomy Ashwag

More information

Trabeculectomy is an effective method for lowering

Trabeculectomy is an effective method for lowering ORIGINAL STUDY Refractive Outcome of Cataract Surgery in Eyes With Prior Trabeculectomy: Risk Factors for Postoperative Myopia Oliver L. Yeh, MD, Karine D. Bojikian, MD, Mark A. Slabaugh, MD, and Philip

More information

Safety and satisfaction of myopic small-incision lenticule extraction combined with monovision

Safety and satisfaction of myopic small-incision lenticule extraction combined with monovision Fu et al. BMC Ophthalmology (2018) 18:131 https://doi.org/10.1186/s12886-018-0794-2 RESEARCH ARTICLE Safety and satisfaction of myopic small-incision lenticule extraction combined with monovision Dan Fu

More information

The Egyptian Journal of Hospital Medicine (October 2018) Vol. 73 (9), Page

The Egyptian Journal of Hospital Medicine (October 2018) Vol. 73 (9), Page The Egyptian Journal of Hospital Medicine (October 2018) Vol. 73 (9), Page 7580-7586 Outcome of PRK in Management of Post LISIK Residual Myopia and Myopic Astigmatism Department of Ophthalmology, Faculty

More information

Comparison of Corneal and Anterior Chamber Parameters following Myopic laser in situ keratomileusis and photorefractive keratectomy by

Comparison of Corneal and Anterior Chamber Parameters following Myopic laser in situ keratomileusis and photorefractive keratectomy by Comparison of Corneal and Anterior Chamber Parameters following Myopic laser in situ keratomileusis and photorefractive keratectomy by Pentacam as A New Imaging Technique Mohammad Ali Zare, MD 1 Hassan

More information

CLINICAL SCIENCES. Clinical Significance of Central Corneal Thickness in the Management of Glaucoma

CLINICAL SCIENCES. Clinical Significance of Central Corneal Thickness in the Management of Glaucoma CLINICAL SCIENCES Clinical Significance of Central Corneal Thickness in the Management of Glaucoma Carolyn Y. Shih, MD; Joshua S. Graff Zivin, PhD; Stephen L. Trokel, MD; James C. Tsai, MD Objective: To

More information

Comparison of Newer IOL Power Calculation Methods for Eyes With Previous Radial Keratotomy PATIENTS AND METHODS. Patients

Comparison of Newer IOL Power Calculation Methods for Eyes With Previous Radial Keratotomy PATIENTS AND METHODS. Patients Special Issue Comparison of Newer IOL Power Calculation Methods for Eyes With Previous Radial Keratotomy Jack X. Ma, 1 Maolong Tang, 2 Li Wang, 3 Mitchell P. Weikert, 3 David Huang, 2 and Douglas D. Koch

More information

Correspondence should be addressed to Xingtao Zhou;

Correspondence should be addressed to Xingtao Zhou; Hindawi Ophthalmology Volume 2017, Article ID 9659481, 8 pages https://doi.org/10.1155/2017/9659481 Clinical Study Comparison of Corneal Power and Astigmatism between Simulated Keratometry, True Net Power,

More information

pre-laser cut pre-laser cut Pre-operative Known and Potential Complications of SMILE Failure to obtain an adequate suction

pre-laser cut pre-laser cut Pre-operative Known and Potential Complications of SMILE Failure to obtain an adequate suction pre-laser cut! Known and Potential Complications of SMILE Failure to obtain an adequate suction Walter Sekundo Correct treatment pack size (S in myopic cases) Philipps University Marburg/Germany Use speculum

More information

Ocular Rigidity Evaluation After Photorefractive Keratectomy: An Experimental Study

Ocular Rigidity Evaluation After Photorefractive Keratectomy: An Experimental Study BIOMECHANICS Ocular Rigidity Evaluation After Photorefractive Keratectomy: An Experimental Study George D. Kymionis, MD, PhD; Vasilios F. Diakonis, MD; George Kounis, BSc; Spyridon Charisis, MD; Dimitrios

More information

ONE THOUSAND WAVEFRONT GIDED TREATMENT ON MICROSCAN VISUM. Mickael Yablokov. I have no any financial interests in any products mentioned in this paper

ONE THOUSAND WAVEFRONT GIDED TREATMENT ON MICROSCAN VISUM. Mickael Yablokov. I have no any financial interests in any products mentioned in this paper ONE THOUSAND WAVEFRONT GIDED TREATMENT ON MICROSCAN VISUM Mickael Yablokov I have no any financial interests in any products mentioned in this paper Ophthalmology clinic Eye Surgery, Kostroma, Russia Goal

More information

Comparison of Intraocular Lens Power Calculation Methods Following Myopic Laser Refractive Surgery: New Options Using a Rotating Scheimpflug Camera

Comparison of Intraocular Lens Power Calculation Methods Following Myopic Laser Refractive Surgery: New Options Using a Rotating Scheimpflug Camera pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2018;32(6):497-505 https://doi.org/10.3341/kjo.2018.0008 Original Article Comparison of Intraocular Lens Power Calculation Methods Following Myopic

More information

Biomechanical Weakening of Different Re-treatment Options After Small Incision Lenticule Extraction (SMILE)

Biomechanical Weakening of Different Re-treatment Options After Small Incision Lenticule Extraction (SMILE) Biomechanical Weakening of Different Re-treatment Options After Small Incision Lenticule Extraction (SMILE) Sabine Kling, PhD; Bogdan Spiru, MD; Farhad Hafezi, MD, PhD; Walter Sekundo, MD, PhD ABSTRACT

More information

Single-step Transepithelial photorefractive keratectomy in the treatment of mild, moderate, and high myopia: six month results

Single-step Transepithelial photorefractive keratectomy in the treatment of mild, moderate, and high myopia: six month results Xi et al. BMC Ophthalmology (2018) 18:209 https://doi.org/10.1186/s12886-018-0888-x RESEARCH ARTICLE Open Access Single-step Transepithelial photorefractive keratectomy in the treatment of mild, moderate,

More information

Clinical experience of 9,000 small aperture Inlays for presbyopia correction

Clinical experience of 9,000 small aperture Inlays for presbyopia correction Clinical experience of 9,000 small aperture Inlays for presbyopia correction Minoru Tomita, MD, PhD Shinagawa LASIK Center, Tokyo, Japan September 7 th, 2012, ISOP meeting in Tokyo, JAPAN 1,060,666 Femto

More information

Summary Recommendations for Keratorefractive Laser Surgery June 2013

Summary Recommendations for Keratorefractive Laser Surgery June 2013 Summary Recommendations for Keratorefractive Laser Surgery June 2013 Background Laser assisted in-situ keratomileusis (LASIK) surgery is the most commonly performed keratorefractive surgery; altering the

More information

1 Birmingham and Midland Eye Centre, City Hospital, Birmingham, 2 Ophthalmic Research Group, Life and Health Sciences, Aston

1 Birmingham and Midland Eye Centre, City Hospital, Birmingham, 2 Ophthalmic Research Group, Life and Health Sciences, Aston Accuracy of Goldmann, Ocular Response Analyser, Pascal and TonoPen XL Tonometry in Keratoconic and Normal Eyes Susan P Mollan MB CHB MRCOphth 1, James S Wolffsohn BSc PhD PgDip MCOptom 2, Maged Nessim

More information

Sensations of Chinese Ametropia Patients under Laser-Assisted Keratomileusis Surgical Techniques

Sensations of Chinese Ametropia Patients under Laser-Assisted Keratomileusis Surgical Techniques Sensations of Chinese Ametropia Patients under Laser-Assisted Keratomileusis Surgical Techniques Jing Zhu, MD 1 Ji-Feng Yu, MD 2 Gai-Ping Du, MD 2 Mei Ge, MD 2 Yi-Fei Huang, MD 2 Yu-Li Pi, MD 1 Abstract

More information

Evolution in Visual Freedom.

Evolution in Visual Freedom. Evolution in Visual Freedom. The EVO Visian ICL Advantages Many vision correction procedures promise an improved level of vision, but few vision correction alternatives offer the quality and features

More information

Central corneal thickness (CCT) measurement is a critical

Central corneal thickness (CCT) measurement is a critical ARTICLE Topographic Paracentral Corneal Thickness With Pentacam and Orbscan: Effect of Acoustic Factor Javier González-Pérez, O.D., M.Sc., Ph.D., Jose M. González-Méijome, O.D., Ph.D., María T. Rodríguez

More information

IOL Master. Photorefractive keratectomy

IOL Master. Photorefractive keratectomy 89/11/3 : 89/9/3 : 1389 /119 / IOL Master * Photorefractive keratectomy 3 2 1 2 4 Photorefractive keratectomy(prk) (IOL) :. IoL-Master.. (clinical trial) :. 30 20 35.. PRK. IOL Master ( GM300,china) IOL.

More information

SMILE A Solution to Those who go in Harm s Way

SMILE A Solution to Those who go in Harm s Way SMILE A Solution to Those who go in Harm s Way Steven Schallhorn, M.D. Chief Medical Officer November 12, 2016 Operational Basis for Involvement Commander of Naval Special Warfare identified deficiencies

More information

Inaccuracy of Intraocular Lens Power Prediction for Cataract Surgery in Angle-Closure Glaucoma

Inaccuracy of Intraocular Lens Power Prediction for Cataract Surgery in Angle-Closure Glaucoma Original Article DOI 10.3349/ymj.2009.50.2.206 pissn: 0513-5796, eissn: 1976-2437 Yonsei Med J 50(2):206-210, 2009 Inaccuracy of Intraocular Lens Power Prediction for Cataract Surgery in Angle-Closure

More information

The pinnacle of refractive performance.

The pinnacle of refractive performance. The pinnacle of refractive performance. WaveLight REFRACTIVE PORTFOLIO Advancing REFRACTIVE SURGERY Contoura Vision sets a new standard in LASIK outcomes More than 98% of patients would choose it again.

More information

LASIK Flap Thickness Accuracy after Using Mechanical Microkeratome

LASIK Flap Thickness Accuracy after Using Mechanical Microkeratome Med. J. Cairo Univ., Vol. 84, No. 1, June: 733-737, 2016 www.medicaljournalofcairouniversity.net LASIK Flap Thickness Accuracy after Using Mechanical Microkeratome AYA H. FARAG, M.Sc.; RANIA M. SOBHY,

More information

Correspondence should be addressed to Fusako Fujimura;

Correspondence should be addressed to Fusako Fujimura; BioMed Research International Volume 2013, Article ID 370592, 5 pages http://dx.doi.org/10.1155/2013/370592 Research Article Repeatability and Reproducibility of Measurements Using a NT-530P Noncontact

More information

Effects of laser in situ keratomileusis (LASIK) on corneal biomechanical measurements with the Corvis ST tonometer

Effects of laser in situ keratomileusis (LASIK) on corneal biomechanical measurements with the Corvis ST tonometer Clinical Ophthalmology open access to scientific and medical research Open Access Full Text Article Original Research Effects of laser in situ keratomileusis (LASIK) on corneal biomechanical measurements

More information

The Visian ICL Advantages

The Visian ICL Advantages The Visian ICL Advantages Many vision correction procedures promise an improved level of vision, but few vision correction alternatives offer the quality and features found with the Visian ICL. These include:

More information

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer

Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer 518 EXTENDED REPORT Effect of corneal parameters on measurements using the pulsatile ocular blood flow tonograph and Goldmann applanation tonometer P Gunvant, M Baskaran, L Vijaya, I S Joseph, R J Watkins,

More information

Nature and Science 2016;14(9)

Nature and Science 2016;14(9) Comparison between Implantable Contact Lens (ICL) versus Acry Sof Cachet Phakic Intraocular Lenses in Correction of Moderate to High Myopia Khaled Nada, M. Sc.; Mohammed Attia, M. D and Ashraf El Habbak,

More information

KNOW THE OPTIONS. Discover how the latest advances in vision correction can improve your sight.

KNOW THE OPTIONS. Discover how the latest advances in vision correction can improve your sight. KNOW THE OPTIONS. LASIK VISIAN ICL PRK Discover how the latest advances in vision correction can improve your sight. Today, you can choose from several choices of permanent vision correction procedures

More information

Thirty-month results after the treatment of post-lasik ectasia with allogenic lenticule addition and corneal cross-linking: a case report

Thirty-month results after the treatment of post-lasik ectasia with allogenic lenticule addition and corneal cross-linking: a case report Li et al. BMC Ophthalmology (2018) 18:294 https://doi.org/10.1186/s12886-018-0967-z CASE REPORT Open Access Thirty-month results after the treatment of post-lasik ectasia with allogenic lenticule addition

More information

Predictability and accuracy of IOL formulas in high myopia

Predictability and accuracy of IOL formulas in high myopia ARTICLE Predictability and accuracy of IOL formulas in high myopia Mohamed Yasser Sayed Saif, MD 1 ; Mohamed Othman Abdel Khalek, MD 1 ; Ahmed Tamer Sayed Saif, MD 2 ; Passant Sayed Saif, MD 3 ; Sherif

More information

Comparison of Corneal Power and Intraocular Lens Power Calculation Methods after LASIK for Myopia

Comparison of Corneal Power and Intraocular Lens Power Calculation Methods after LASIK for Myopia Comparison of Corneal Power and Intraocular Lens Power Calculation Methods after LASIK for Myopia Seyed Mohammad Reza Taheri, MD 1 Azita Kheiltash, MD, MPH 2 Hassan Hashemi, MD 1,3 Abstract Purpose: To

More information

Jing Zhao 1, Peijun Yao 1, Meiyan Li 1, Zhi Chen 1, Yang Shen 1, Zhennan Zhao 1, Zimei Zhou 2, Xingtao Zhou 1 * Abstract.

Jing Zhao 1, Peijun Yao 1, Meiyan Li 1, Zhi Chen 1, Yang Shen 1, Zhennan Zhao 1, Zimei Zhou 2, Xingtao Zhou 1 * Abstract. The Morphology of Corneal Cap and Its Relation to Refractive Outcomes in Femtosecond Laser Small Incision Lenticule Extraction (SMILE) with Anterior Segment Optical Coherence Tomography Observation Jing

More information

VisuMax from ZEISS Defining the pulse rate in refractive surgery

VisuMax from ZEISS Defining the pulse rate in refractive surgery VisuMax from ZEISS Defining the pulse rate in refractive surgery Remarkable precision and detail Defining new trends in modern corneal surgery As a ground-breaking, high-performance femtosecond laser

More information

The innovative aspects are that ORA G3 is currently the only device capable of measuring corneal hysteresis.

The innovative aspects are that ORA G3 is currently the only device capable of measuring corneal hysteresis. pat hways ORA G3 to measure corneal hysteresis Medtech innovation briefing Published: 18 June 2018 nice.org.uk/guidance/mib150 Summary The technology described in this briefing is Ocular Response Analyzer

More information

Abstracts. Edited by Dr. Tahir Mahmood. Effect of phacoemulsification on intraocular pressure in eyes with pseudoexfoliation Single-surgeon series

Abstracts. Edited by Dr. Tahir Mahmood. Effect of phacoemulsification on intraocular pressure in eyes with pseudoexfoliation Single-surgeon series Abstracts Edited by Dr. Tahir Mahmood Effect of phacoemulsification on intraocular pressure in eyes with pseudoexfoliation Single-surgeon series Shingleton BJ, Laul A, Nagao K, Wolff B, Donoghue MO, Eagan

More information

Comparison between toric and spherical phakic intraocular lenses combined with astigmatic keratotomy for high myopic astigmatism

Comparison between toric and spherical phakic intraocular lenses combined with astigmatic keratotomy for high myopic astigmatism Zheng et al. Eye and Vision (2017) 4:20 DOI 10.1186/s40662-017-0085-7 RESEARCH Open Access Comparison between toric and spherical phakic intraocular lenses combined with astigmatic keratotomy for high

More information