NEW. Fully Automated Solution. Metabolic Disorders Diabetes Vitamin Deficiencies Inflammatory Diseases Clinical Chemistry Specific Proteins TDM DOA

Size: px
Start display at page:

Download "NEW. Fully Automated Solution. Metabolic Disorders Diabetes Vitamin Deficiencies Inflammatory Diseases Clinical Chemistry Specific Proteins TDM DOA"

Transcription

1 NEW FAST & ACCURATE DIAGNOSIS OF: Metabolic Disorders Diabetes Vitamin Deficiencies Inflammatory Diseases Clinical Chemistry Specific Proteins TDM DOA Fully Automated Solution Reliable User-friendly Fast results

2 COMPACT & VERSATILE A FULLY AUTOMATED SOLUTION A fully automated, hihly interated compact analyser. Specially desined for small to mid-sized laboratories, doctor offices, specific hospital settins, (rural) labs. Easy to operate menu for fast startup and minimum down time. Disposable reaction cells. Low water consumption. Minimum maintenance required. Very cost effective and precise. 2 years warranty. Fully developed and made in Italy.

3 hs-crp HbA1c Microalbumin & Glucose Clinical Chemistry Specific Proteins Vitamin D Cobalamin (Vit.B12) * Folic Acid (Vit.B9) * TDM * DOA * * Comin soon ALL IN ONE OPERATOR CONSOLE H Hemo One Instrument Unit Graphic and friendly interface assists the operator and simplifies the daily routine work The Hemo One software is modular and expandable for future parameters Simple to operate, minimum trainin requered Remote maintanance possible on demand * Based on MS Windows 10 operatin system HEMO ONE

4 SMALL FOOTPRINT & FLEXIBILITY IS THE ANSWER RELIABLE, FAST & SIMPLE FULLY AUTOMATED SOLUTION Throuhput Pretreatment Number of arms Number of reaents positions Number of samples / calibrators / controls Vials sizes Diluter Reaent volume Sample volume Dosin resolution Typical readin volume Calibration Calibration curves Automatic dilution Incubation & Readin cuvettes Up to 120 tests/hr mono-reaent Up to 60 tests/hr bi-reaent On board, automatic pretreatment of whole blood with HbA1c lysin reaent 1 liquid dispenser arm with capacitive liquid level detector and obstacle sensor mm Ø with 75/85 mm heiht, and 3 ml sample cups 1 hih-precision micro-meterin pump for dosin reaents and samples μl μl 1 microliter 200/250 μl On-line Calibration, QC and patient results archive Linear reression, piece-wise, cubic spline, polynomial (selected automatically by assay application) Automatic / on request 72 disposable on-board

5 TECHNICAL SPECIFICATIONS SIMPLE TO OPERATE - LOW MAINTENANCE Reaction temperature Wavelenths Liht source Photometric linearity Water consumption Reaent cooler Barcode Interface to LIS host STAT function Operator Console +37 C ± 0.1 C 8 from 340 to 700 nm Lon life haloen lamp (2000 hours life) OD Low water consumption due to use of disposable cuvettes Up to 14 C below ambient temperature (optional) Yes (fully interated for sample and reaents) Bi-directional connection, Ethernet Selectable on all sample positions External, All-in-One computer with Touch Screen Operational system MS Windows 10 GUI Printer Workin Environment Real-time electronics Power manaement Power supply Dimensions Weiht Easy to use and wizard-style user interface USB connection Temperature C Relative humidity % Modular, SMD Automatic start-up and shut-down Vac, Hz 45(W) x 46(D) x 50(H) cm 25 k HEMO ONE

6 TESTS MENU HEMO ONE TESTS HbA1c MICROALBUMIN GLUCOSE hs-crp VITAMIN D VITAMIN B12* VITAMIN B9* TDM* DOA* * Comin soon CLINICAL CHEMISTRY REAGENT KITS ALBUMIN BCG CK MB SL IRON ALT / GPT SL CK NAC SL MAGNESIUM ALP (DEA) SL CREATININE PHOSPHOROUS UV AMYLASE GAMMA GT SL TOTAL PROTEIN AST / GOT SL GLUCOSE PAP TRIGLYCERIDES BILIRUBIN DIRECT HDL CHOLESTEROL UREA UV SL BILIRUBIN TOTAL LDL CHOLESTEROL URIC ACID CALCIUM ARSENAZO LDH-P SL CHOLINESTERASE CHOLESTEROL PAP TURBIDIMETRY REAGENT KITS ALBUMIN CERULOPLASMIN IM ALFA-1 - ACID GLYCOPROTEIN COMPLEMENT C3 KAPPA LIGHT CHAIN ALFA-1 - ANTITRYPSIN COMPLEMENT C4 LAMBDA LIGHT CHAIN ALFA-2 MACROGLOBULIN CRP LIPOPROTEIN (A) ANTITHROMBIN III FIBRINOGEN MICROALBUMIN APOLIPO PROTEIN A1 HAPTOGLOBIN PREALBUMIN APOLIPO PROTEIN B IA TRANSFERRIN C1 ESTERASE INHIBITOR IG CE-IVD marked reaents panel: Ready to use Stable formulations based on IFCC & DGKC recommendations for whole blood, serum, plasma and urine samples LATEX REAGENT KITS ANTI-STREPTOLYSIN (O) BETA 2 - MICROGLOBULIN FERRITIN RHEUMATOID FACTOR GENERIC CALIBRATORS & CONTROLS MULTICALIBRATOR NORMAL CONTROL SERUM PATHOLOGICAL CONTROL SERUM

7 Positive identification of reaents ives the end user the assurance to work without compromises on quality. Twenty-eiht parameters for enzymes and substrates, with application on serum, plasma and urine, based on the most advanced research in clinical chemistry followin international recommendations (IFCC). Twenty-eiht parameters for specific protein, with application on serum, plasma and urine, standardized with 5-point calibration curve. HEMO ONE

8 R&D and Production: I.S.E. S.r.l. Via Luii Einaudi, 7 Guidonia Montecelio Rome, Italy Tel: Fax: Leal site: I.S.E. S.r.l. Via delle Driadi, Rome, Italy I.S.E. is a dynamic company specialized in development and manufacturin of Laboratory Analysers and associated Reaents. I.S.E. is an ISO 9001:2008 and ISO 13485:2012 certified company and all our products are CE marked. Several other certifications available. I.S.E. have thousands of solutions installed worldwide. I.S.E. provides to our customers hih end, hih quality and reliable solutions of Analysers and Reaents. Ease of use, combined with minimal operatin requirements makes ISE systems the best choice for any laboratory. Customer Care Center: info@lootech-ise.com Tel: Fax: Sales and Marketin office: sales@lootech-ise.com Tel: Fax: We are dedicated to customer satisfaction and will do the utmost to respond quickly to your needs. Technical service: service@lootech-ise.com Tel: Fax: Order handlin and loistics: order@lootech-ise.com Tel: Fax: Hemo One Ref. BRO1010 V2.1 I.S.E S.r.l. All rihts reserved. All trademarks are property of their respective owners. Specifications are subject to chane without notice.

Optimized for best performance in clinical chemistry testing

Optimized for best performance in clinical chemistry testing Optimized for best performance in clinical chemistry testing System Reagents for Indiko and Konelab clinical and specialty chemistry analyzers Complete system solutions Thermo Scientific system reagents

More information

Excellence and confidence

Excellence and confidence Thermo Scientific System Reagents Fully supported and guaranteed, CE marked system solutions Streamlined supply and support Maximum stability and reduced waste Standardised performance in External Quality

More information

PRODUCTS FOR EXPORT 2018

PRODUCTS FOR EXPORT 2018 PRODUCTS FOR EXPORT 2018 MEDICON HELLAS SA 5-7 Melitona st., 153 44 Gerakas, Attiki, Greece - Tel.:+30 210 6606000 FAX:+30 210 6612666 e-mail:diag@mediconsa.com, http://www.mediconsa.com General Electronic

More information

Thermo Scientific System Reagents Excellence in Clinical Chemistry

Thermo Scientific System Reagents Excellence in Clinical Chemistry Thermo Scientific System Reagents Excellence in Clinical Chemistry Part of Thermo Fisher Scientific Covering over 150 CE marked products, Thermo Scientific system reagents are specifically developed and

More information

Thermo Scientific Konelab System Reagents For convenient and reliable analysis

Thermo Scientific Konelab System Reagents For convenient and reliable analysis Thermo Scientific Konelab System Reagents For convenient and reliable analysis Part of Thermo Fisher Scientific Thermo Scientific Konelab system reagents ensure the high quality analysis results Easy-to-use

More information

DEDICATED LINES LÍNEAS DEDICADAS

DEDICATED LINES LÍNEAS DEDICADAS DEDICATED LINES LÍNEAS DEDICADAS DEDICATED LINES LÍNEAS DEDICADAS SPINLAB / SELECTRA - FLEXOR SYSTEM PRODUCT PRODUCTO METHOD MÉTODO SIZE PRESENTACIÓN REF. CÓDIGO BIOCHEMISTRY BIOQUÍMICA ALBUMIN ALBÚMINA

More information

INDEX PAG CLINICAL CHEMISTRY Enzymes, Substrate, Electrolytes... PAG. 5 - CALIBRATORS CONTROLS... PAG. 6 - ELECTROPHORESIS. PAG.

INDEX PAG CLINICAL CHEMISTRY Enzymes, Substrate, Electrolytes... PAG. 5 - CALIBRATORS CONTROLS... PAG. 6 - ELECTROPHORESIS. PAG. INDEX - CLINICAL CHEMISTRY Enzymes, Substrate, Electrolytes...... - CALIBRATORS CONTROLS..... - ELECTROPHORESIS. - Minipohor 08 - Dedicated Reagents.... - IMMUNOTURBIDIMETRY.... PAG. 1-5 PAG. 5 PAG. 6

More information

BS-230. Clinical Chemistry Analyzer

BS-230. Clinical Chemistry Analyzer BS-230 Clinical Chemistry Analyzer Flexible loading: 80 sample positions, Up to 80 reagent positions. Up to (40 fixed + 40 interchangeable) μl minimum reaction volume Disposable Cuvettes to avoid contamination

More information

short catalogue diasys diagnostic systems clinical chemistry immunoturbidimetric tests calibrators standards controls supplementary reagents

short catalogue diasys diagnostic systems clinical chemistry immunoturbidimetric tests calibrators standards controls supplementary reagents ::010 ::011 ::012 ::013 ::014 ::015 ::016 ::017 ::018 short catalogue 11 ::026 ::027 ::028 ::029 ::030 ::031 ::032 ::036 ::037 ::038 ::039 ::043 ::044 ::045 clinical chemistry ::048 ::049 immunoturbidimetric

More information

short catalogue clinical chemistry immunoturbidimetric tests calibrators standards controls supplementary reagents instruments Probedruck ::018 ::016

short catalogue clinical chemistry immunoturbidimetric tests calibrators standards controls supplementary reagents instruments Probedruck ::018 ::016 DiaSys_Kurzkatalog_2015_141209 10.12.2014 12:07 Uhr Seite 1 C ::010 ::011 ::012 ::013 ::014 M Y CM MY ::015 CY CMY K ::016 ::017 15 short catalogue ::026 ::027 ::028 ::029 ::036 ::030 ::037 ::018 ::031

More information

Front Cover PRICE LIST

Front Cover PRICE LIST Front Cover PRICE LIST w.e.f st July, 0 PACKSIZE KITMRP 9 0 9 0 X0ML X0ML 00ML XML XML XML X00ML XML X0ML 9.00,.00,.00,.00.00 9.00,.00,.00,90.00.00.00,0.00.00,00.00,.00,9.00,.00,9.00 9,.00 9.00.00 AMYLASE-LQ

More information

REAGENTS THE HIGHEST QUALITY RANGE OF ROUTINE AND NOVEL REAGENTS

REAGENTS THE HIGHEST QUALITY RANGE OF ROUTINE AND NOVEL REAGENTS THE HIGHEST QUALITY RANGE OF ROUTINE AND NOVEL REAGENTS Advancing Biochemistry Testing for Laboratories CONTENTS 01 06 43 46 53 55 60 BENEFITS OF RANDOX REAGENTS REAGENTS - RANDOX THIRD PARTY REAGENTS

More information

Roche/Hitachi - PreciControl ClinChem Multi 2

Roche/Hitachi - PreciControl ClinChem Multi 2 ATRYP Antitrypsin alpha 1 ERM-DA470k/IFCC 9 136 1.36 1.84 0.0184 GPROT Acid glycoprotein alpha 1 CRM 470 2 90.1 0.901 0.890 0.00890 ACP Acid phosphatase total 1-naphthyl phosphate 0.720 43.1 0.00703 0.421

More information

Uni-Asia Scientific Instrument Company Limited. Stanbio Laboratory Product List

Uni-Asia Scientific Instrument Company Limited. Stanbio Laboratory Product List 0130-430 Magnesium LiquiColor Test 0140-050 Sodium Test 0150-250 Calcium (CPC) LiquiColor Test 0153-030 Calcium Standard (10 mg/dl) 0155-225 Calcium (Arsenazo) LiquiColor Test 0160-050 Potassium Test 0210-250

More information

cobas c 501 analyzer and cobas c 311 analyzer Within Run Imprecision Guidelines

cobas c 501 analyzer and cobas c 311 analyzer Within Run Imprecision Guidelines cobas c 501 analyzer and cobas c 311 analyzer General Information How to use these guidelines Unless otherwise indicated, the data presented is the same for both the cobas c 501 analyzer and the cobas

More information

Clinical Chemistry Reagents Brochure

Clinical Chemistry Reagents Brochure Clinical Chemistry Reagents Brochure ekfdiagnostics.com Central Laboratory STANBIOChemistry from EKF Diagnostics Welcome to our Reagents Brochure EKF Diagnostics Stanbio Chemistry menu includes liquid-stable

More information

The power of proven technology

The power of proven technology Clinical Chemistry Critical Care Haemostasis Information Systems TEST CONSOLIDATION FLEXIBILITY PRODUCTIVITY EASE OF USE TRACEABILITY QUALITY RESULTS The power of proven technology Test Consolidation Flexibility

More information

Daily Quality Control Calibration Verification / Linearity. Quality control made easy. Product Information

Daily Quality Control Calibration Verification / Linearity. Quality control made easy. Product Information Daily Quality Control Calibration Verification / Linearity Quality control made easy. Product Information AUDIT MicroControls Making life in the lab easier. AUDIT provides value to customers through high-quality

More information

Clinical Chemisty Reagents Brochure. ekfdiagnostics.com STANBIOChemistry from EKF Diagnostics. Central Laboratory

Clinical Chemisty Reagents Brochure. ekfdiagnostics.com STANBIOChemistry from EKF Diagnostics. Central Laboratory Clinical Chemisty Reagents Brochure ekfdiagnostics.com STANBIOChemistry from EKF Diagnostics Central Laboratory Welcome to our Reagents Brochure EKF Diagnostics Stanbio Chemistry menu includes liquid-stable

More information

QUALITY CONTROL. Linearity Sets

QUALITY CONTROL. Linearity Sets QUALITY CONTROL Linearity Sets The new Acusera Linearity Sets have been designed with convenience in mind, helping you to easily meet CLIA requirements for calibration verification and assessment of linearity.

More information

WSLH. Calibration Verification/ Linearity Products. roficiency. esting. Products provided in partnership with:

WSLH. Calibration Verification/ Linearity Products. roficiency. esting. Products provided in partnership with: WSLH PT roficiency esting Calibration Verification/ Linearity Products Products provided in partnership with: www.wslhpt.org 800-462-5261 PTService@slh.wisc.edu General Chemistry Ammonia/Ethanol - 5 x

More information

Turbidos. Design Verification. Contents

Turbidos. Design Verification. Contents Design Verification Turbidos Contents 1 adjustment... 2 2 Target value determination... 2 3 Stability... 2 3.1 Accelerated stress data... 2 3.2 Open vial stability... 3 3.3 Real Time Stability... 4 4 Result

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2) (b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

The highest quality range of routine and novel reagents REAGENTS

The highest quality range of routine and novel reagents REAGENTS The highest quality range of routine and novel reagents REAGENTS 1 2 Advancing biochemistry testing for laboratories INTRODUCTION TO RANDOX REAGENTS Randox offers an extensive range of third party diagnostic

More information

The power of proven technology

The power of proven technology Clinical Chemistry Critical Care Haemostasis Information Systems TEST CONSOLIDATION FLEXIBILITY PRODUCTIVITY EASE OF USE TRACEABILITY QUALITY RESULTS The power of proven technology Test Consolidation Flexibility

More information

CERTIFICATE OF CONFORMITY

CERTIFICATE OF CONFORMITY TECHEUROPA INSPECTION AND CERTIFICATIONS PRIVATE LIMITED Website: www.tech-europa.com CERTIFICATE OF CONFORMITY Manufacturer Jeev Diagnostics Private Limited #9, 5 th Floor, Gokul Tower, 9 & 10, C.P.Ramasamy

More information

More to Life. Where research becomes the basis of discovering newer ways of alleviating human suffering and empowering an individual with good health.

More to Life. Where research becomes the basis of discovering newer ways of alleviating human suffering and empowering an individual with good health. More to Life Where research becomes the basis of discovering newer ways of alleviating human suffering and empowering an individual with good health. Meril Diagnostics Emerging from a lineage of successful

More information

CLINICAL CHEMISTRY REAGENTS. Product Profile

CLINICAL CHEMISTRY REAGENTS. Product Profile Product Profile Why Clinical Chemistry Reagents? Quantitative determination of specific analytes associated with various types of disease. Diagnosis Identifying a disease already present Prognosis Forecasting

More information

Serodos and Serodos plus

Serodos and Serodos plus Design Verification Serodos and Serodos plus Contents 1 Value Adjustment... 2 2 Target Determination... 2 3 Stability... 2 Real-Time Stability... 3 Stability after Reconstitution... 4 Stability after Reconstitution

More information

BLOOD IS COMPLEX ANALYZING IT SHOULDN T BE DxH 500 * *Not available for sale in the U.S.

BLOOD IS COMPLEX ANALYZING IT SHOULDN T BE DxH 500 * *Not available for sale in the U.S. BLOOD IS COMPLEX ANALYZING IT SHOULDN T BE DxH 500 * *Not available for sale in the U.S. Introducing the DxH 500, an Open-vial Hematology System *. Quality 5-part Differential in a Compact Design The first

More information

Heflotron" Plus - An enviable asset

Heflotron Plus - An enviable asset / Heflotron" Plus - An enviable asset Rejlotronw - An enviable asset to test clinical chemistry parameters...... in primary care settings for daily routine diagnostics in small series or for single determinations...

More information

Carry-over Evasion List

Carry-over Evasion List Version 22 Note: It is possible that non-roche reagents may cause carry-over interference. Roche is not responsible for any carry-over interference caused by non-roche reagents. Urea and Ammonia should

More information

RX series analyser overview

RX series analyser overview RX series analyser overview Excellence in clinical chemistry testing therxseries.com Expect innovation, accept no imitation Patient care is the primary focus of clinical chemistry testing and Randox has

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Tameside and Glossop Integrated Care NHS Foundation Trust Department of Blood Sciences Tameside General Hospital New Fountain House Ashton-under-Lyne

More information

Quantitative Measurement of Emergency Biomarkers in Parallel

Quantitative Measurement of Emergency Biomarkers in Parallel Point-of-Care Immunoassay Analyzer Quantitative Measurement of Emergency Biomarkers in Parallel Troponin I, Myoglobin, CK-MB, D-Dimer, NTproBNP, hscrp Results in 17 minutes Direct measurement from whole

More information

therxseries.com Rapid, comprehensive clinical chemistry testing on a superior fully automated analyser

therxseries.com Rapid, comprehensive clinical chemistry testing on a superior fully automated analyser therxseries.com Rapid, comprehensive clinical chemistry testing on a superior fully automated analyser The RX imola is a cost effective system that delivers consistent high quality results. Capable of

More information

Reagents. ApTT Cu Hp MAU D3-HB CH. CHE Li Na Zn TAS HDL LDL EDDP PT Lp(a) C. ApTT C ApTT Cu Hp MAU D3-HB CHE L. ApTT Cu Hp

Reagents. ApTT Cu Hp MAU D3-HB CH. CHE Li Na Zn TAS HDL LDL EDDP PT Lp(a) C. ApTT C ApTT Cu Hp MAU D3-HB CHE L. ApTT Cu Hp R E A G E N T S The highest quality range of routine and novel reagents DP PT Lp(a) C T Cu Hp MAU D3-HB HFABP Apo A-1PHE EDDP DP PT Lp(a) CO 2 ApTT Cu Hp u Hp MAU D3-HB CHE Li Na Zn ABP Apo A-1 PHE EDDP

More information

PRICE LIST RELIABLE ACCURATE COST EFFECTIVE. American Technology Made in India For India. W.E.F April 2018

PRICE LIST RELIABLE ACCURATE COST EFFECTIVE. American Technology Made in India For India. W.E.F April 2018 PRICE LIST W.E.F April 2018 RELIABLE ACCURATE COST EFFECTIVE American Technology Made in India For India +91-44-22541131 www.athenesedx.com info@athenesedx.com Code OnSite Rapid Tests R0061C R0062C R0062C

More information

General Chemistry Scheme Guide

General Chemistry Scheme Guide General Chemistry Scheme Guide Copyright WEQAS. All rights reserved. No part of this document may be reproduced or utilised in any form without permission from WEQAS Contents. Scheme details and repertoire.....

More information

RX SERIES ANALYSER OVERVIEW EXCELLENCE IN CLINICAL CHEMISTRY TESTING

RX SERIES ANALYSER OVERVIEW EXCELLENCE IN CLINICAL CHEMISTRY TESTING RX SERIES ANALYSER OVERVIEW EXCELLENCE IN CLINICAL CHEMISTRY TESTING 01 INTRODUCTION 02 THE RX SERIES 04 RX ALTONA 06 RX MONACO 08 RX DAYTONA+ 10 RX IMOLA 12 RX MODENA 14 THE RX SERIES TEST MENU 16 THE

More information

Reagents. Reagents. ApTT. ApTT Cu Hp MAU D3-HB CH. CHE Li Na Zn TAS HDL LDL EDDP PT Lp(a) C. ApTT Cu. ApTT Cu Hp MAU D3-HB CHE L

Reagents. Reagents. ApTT. ApTT Cu Hp MAU D3-HB CH. CHE Li Na Zn TAS HDL LDL EDDP PT Lp(a) C. ApTT Cu. ApTT Cu Hp MAU D3-HB CHE L The highest quality range of routine DP PT Lp(a) CO 2 ApTT Cu Hp MAU and novel D3-HB reagents CH T Cu Hp MAU D3-HB CHE Li Na Zn TAS HDL L HFABP Apo A-1PHE EDDP PT Lp(a) CO 2 ApTT DP PT Lp(a) CO 2 ApTT

More information

Quantitative Measurement of Cardiac Biomarkers

Quantitative Measurement of Cardiac Biomarkers Cardiac Biomarker Analyzer Quantitative Measurement of Cardiac Biomarkers Troponin I, Myoglobin, CK-MB, D-Dimer, NTproBNP, hscrp Results in 17 minutes Direct measurement from whole blood samples 6 parallel

More information

Laboratory diagnosis of plasma proteins and plasma enzymes

Laboratory diagnosis of plasma proteins and plasma enzymes Laboratory diagnosis of plasma proteins and plasma enzymes Functions of plasma proteins Function: transport humoral immunity enzymes protease inhibitors maintenance of oncotic pressure buffering Example:

More information

TRACEABILITY and UNCERTAINTY 9

TRACEABILITY and UNCERTAINTY 9 AAT Antitrypsin alpha 1 AAGP Acid glycoprotein alpha 1 immunoturbidimetric Gen. Acid phosphatase total 1-naphthyl phosphate Gen. Acid phosphatase total 1-naphthyl phosphate Gen. Integra 00 plus Acid phosphatase,

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2) (b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

Analyte Specimen Demographic Reference Range Units

Analyte Specimen Demographic Reference Range Units Acetone Negative titer Alanine aminotransferase (ALT/SGPT) 10-49 U/L Albumin 3.2-4.8 g/dl Alcohol < 10 Alpha-fetoprotein (AFP) < 1.3-8.1 ng/ml Alkaline phosphatase 0 7 days 7 30 days 1 3 3 6 6 12 1 3 3

More information

External Quality Assessment for Calibration Laboratories in Laboratory Medicine - RELA -

External Quality Assessment for Calibration Laboratories in Laboratory Medicine - RELA - External Quality Assessment for Calibration Laboratories in Laboratory Medicine - RELA - Anja Kessler Bonn, Germany 1 RELA Surveys www.dgkl-rfb.de 2 RELA Annual Process Each participant receives two different

More information

TRACEABILITY and UNCERTAINTY

TRACEABILITY and UNCERTAINTY Cat. No. 0 79 0 90 ACP Acid phosphatase total -naphthyl phosphate NPP Acid phosphatase, non-prostatic -naphthyl phosphate (Inhib.:tartrate) ALB Albumin BCG plus ALB Albumin BCP ALP Alkaline phosphatase

More information

The analytical phase

The analytical phase The analytical phase Result interpretation Test request Result Sampling Black box: the lab ANALYTICAL PHASE The CASE Uncle Pete, 67 years old Marked abdominal pain 8 pm, ED Acute abdomen? Assessment (+

More information

LIQUID ASSAYED CHEMISTRY CONTROL PREMIUM PLUS - LEVEL 1 (LIQ CHEM ASY PREMIUM PLUS 1)

LIQUID ASSAYED CHEMISTRY CONTROL PREMIUM PLUS - LEVEL 1 (LIQ CHEM ASY PREMIUM PLUS 1) 0086 LIQUID ASSAYED CHEMISTRY CONTROL PREMIUM PLUS - LEVEL 1 (LIQ CHEM ASY PREMIUM PLUS 1) CAT. NO. LAL 4213 LOT NO. 238UL SIZE: 12 x 5 ml EXPIRY: 2018-04-28 GTIN: 05055273209006 INTENDED USE This product

More information

Detection. personal. Now, you can optimize your personal workflow. Promega instruments and reagents integrate easily.

Detection. personal. Now, you can optimize your personal workflow. Promega instruments and reagents integrate easily. personal Detection Now, you can optimize your personal workflow. Promega instruments and reagents integrate easily. An ultra-sensitive, versatile, and affordable single tube luminometer for Life Science

More information

Biocard. 1. Troponin I

Biocard.  1. Troponin I Biocard http://www.anibiotech.fi Biocard Quant Reader is a quantitative desktop reader for all Biocard rapid cardiac tests: Troponin I, Myoglobin, CRP, hscrp, MPO and CK-MB. It has a embedded printer and

More information

Chemistry Reference Ranges and Critical Values

Chemistry Reference Ranges and Critical Values Alanine Aminotransferase (ALT, SGPT) 3-9 years 9-18 years 1-9 years 9-18 years 10-30 U/L 10-30 U/L 10-20 U/L Albumin 0-6 days 6 days - 37 months 37 months - 7 years 7-20 years 2.6-3.6 g/dl 3.4-4.2 g/dl

More information

Chemistry Reference Ranges and Critical Values

Chemistry Reference Ranges and Critical Values Alanine Aminotransferase (ALT, SGPT) 3-9 years 9-18 years 1-9 years 9-18 years 10-25 U/L 10-35 U/L 10-30 U/L 10-25 U/L 10-30 U/L 10-35 U/L 10-25 U/L 10-35 U/L 10-25 U/L 10-20 U/L 10-35 U/L Albumin 0-6

More information

The next generation portable diagnostics system: Over 20 parameters available!

The next generation portable diagnostics system: Over 20 parameters available! www.boditech.co.kr Immunofluorescence Assay System The next generation portable diagnostics system: Over 20 parameters available! Quantitative test results on the spot is an immunofluorescencebased diagnostics

More information

Manufacturer Report for Siemens Unassayed Chemistry Lot Exp 30 Jun 2018

Manufacturer Report for Siemens Unassayed Chemistry Lot Exp 30 Jun 2018 Acetaminophen Enzymatic, colorimetric µg/ml.09 0..0.09 0..0 0. 0. 0. 0. 9.. 9.0 0.9.0..9.. Albumin Bromcresol Purple (BCP) g/dl.0 0.0..0 0.00.. 0.0.. 0.09..9 0.0..9 0.0..0 0.0..0 0.0. Alkaline Phosphatase

More information

Total Cost of Ownership (TCO): An evidence-based approach to compare laboratory equipment

Total Cost of Ownership (TCO): An evidence-based approach to compare laboratory equipment Total Cost of Ownership (TCO): An evidence-based approach to compare laboratory equipment P.C.G. Gontard 1, L.I. Stankevich 1, B.G. Gorodetsky 1 SUMMARY Clinical laboratories across the globe operate in

More information

POC Testing: The New Standard. InnovaStar From DiaSys.

POC Testing: The New Standard. InnovaStar From DiaSys. POC Testing: The New Standard. InnovaStar From DiaSys. Easy to use, superior precision, rapid results: InnovaStar from DiaSys brings POC testing to a whole new level. A fully automatic, compact analyzer

More information

Evidence Based Commutability: Bias 2 Study. Janice Gill Manager RCPAQAP Chemical Pathology Adelaide SA

Evidence Based Commutability: Bias 2 Study. Janice Gill Manager RCPAQAP Chemical Pathology Adelaide SA Evidence Based Commutability: Bias 2 Study Janice Gill Manager RCPAQAP Chemical Pathology Adelaide SA Australian Bias Studies conducted by Gus Koerbin, ACT Pathology on behalf of AACB Harmonisation Committee

More information

Setting of quality standards

Setting of quality standards Setting of quality standards Graham Jones Department of Chemical Pathology St Vincent s Hospital, Sydney AACB ASM Adelaide October 2014 Setting of Quality Standards - 2013 The 2013 QC workshop revealed

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Biochemistry Department Poole Hospital Longfleet Road Poole BH15 2JB Contact: Dr Fergus Jack Tel: +44 (0) 1202 442 497 E-Mail: Fergus.jack@poole.nhs.uk

More information

Abaxis Piccolo xpress TM

Abaxis Piccolo xpress TM Abaxis Piccolo xpress TM A breakthrough in point-of care diagnostics A breakthrough in point of care diagnostics Fast, easy, accurate on-site testing The Piccolo xpress TM is a fully automated system,

More information

DIAZYME PRODUCT LIST LIST INNOVATIONS IN CLINICAL DIAGNOSTICS

DIAZYME PRODUCT LIST LIST INNOVATIONS IN CLINICAL DIAGNOSTICS DIAZYME PRODUCT LIST LIST PRODUCT 2 13 INNOVATIONS IN CLINICAL DIAGNOSTICS About Diazyme Diazyme Laboratories is a Division of General Atomics located in Poway, California. Diazyme uses its proprietary

More information

Glucose analyser GA 3

Glucose analyser GA 3 Glucose analyser GA 3 NEW The GA 3 from KABE LABORTECHNIK for a precise determination of glucose and lactate values Precise, fully automated, quick and economical the GA 3! The GA 3 represents a further

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2) (b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

Types of target values, acceptable ranges

Types of target values, acceptable ranges Types of target values, acceptable ranges As the differential of rounding, maximum 1 percent point deviation is allowed from the maximum acceptable range. 100. Clinical chemistry (wet) 1. Calcium RMV 10

More information

Specific Panels. Celiac disease panel. Pancreas Panel:

Specific Panels. Celiac disease panel. Pancreas Panel: Specific Panels Celiac disease panel Anti Endomysium IgA Anti Endomysium IgG Anti Gliadin IgA Anti Gliadin IgG Anti Transglutaminase IgA Anti Transglutaminase IgG Total IgA Total IgG Stool analysis +Sudan

More information

CALIBRATION SERUM - LEVEL 2 (CAL 2)

CALIBRATION SERUM - LEVEL 2 (CAL 2) CAT. NO. CAL 2350 LOT NO. 1242UN SIZE: 20 x 5ml EXPIRY: 2020-02-28 GTIN: 05055273200959 INTENDED USE For use as a Calibrator in clinical chemistry assays. RANDOX Calibration Sera are based on lyophilised

More information

cobas u 601 urine analyzer Providing precise and secure test results

cobas u 601 urine analyzer Providing precise and secure test results Providing precise and secure test results 1 of 6 Providing precise and secure test results cobas u 601 urine analyzer is a modular, analytical system platform for urine strip testing and features a fully

More information

CALIBRATION SERUM LEVEL 3 (CAL 3)

CALIBRATION SERUM LEVEL 3 (CAL 3) CALIBRATION SERUM LEVEL 3 (CAL 3) CAT. NO. CAL 2351 LOT NO. 907UE SIZE: 20 x 5ml EXPIRY: 2019-07-28 GTIN: 05055273200966 INTENDED USE For use as a Calibrator in clinical chemistry assays. RANDOX Calibration

More information

RX IMOLA A FULLY AUTOMATED CLINICAL CHEMISTRY ANALYSER, WITH A COMBINED THROUGHOUT OF 560 TESTS PER HOUR

RX IMOLA A FULLY AUTOMATED CLINICAL CHEMISTRY ANALYSER, WITH A COMBINED THROUGHOUT OF 560 TESTS PER HOUR RX IMOLA A FULLY AUTOMATED CLINICAL CHEMISTRY ANALYSER, WITH A COMBINED THROUGHOUT OF 560 TESTS PER HOUR THE RX IMOLA DEMONSTRATES HIGH QUALITY TESTING FOR RESULTS YOU CAN TRUST 01 04 BENEFITS SYSTEM OVERVIEW

More information

Specimen Collection Requirements

Specimen Collection Requirements The following is a job aid listing the specimen collection requirements for laboratory testing at Colchester East Hants Health Center. Specimens must be accompanied by the Patient Information Form G09.

More information

Standatrol S-E. 2 niveles. Lyophilized serum for precision control in clinical chemistry

Standatrol S-E. 2 niveles. Lyophilized serum for precision control in clinical chemistry Lot: 1711232000 Level 1: 230680 Level 2: 230700 C Standatrol S-E 2 niveles Lyophilized serum for precision control in clinical chemistry USES Standatrol S-E 2 niveles is adaptable to different uses: -

More information

Standatrol S-E. 2 niveles. Lyophilized serum for precision control in clinical chemistry

Standatrol S-E. 2 niveles. Lyophilized serum for precision control in clinical chemistry Lot: 1702210520 Level 1: 201920 Level 2: 201930 C Standatrol S-E 2 niveles Lyophilized serum for precision control in clinical chemistry USES Standatrol S-E 2 niveles is adaptable to different uses: -

More information

Specimen Collection Requirements

Specimen Collection Requirements The following is a job aid listing the specimen collection requirements for laboratory testing at Colchester East Hants Health Center. Specimens must be accompanied by the Patient Information Form G09.

More information

TRACEABILITY and UNCERTAINTY

TRACEABILITY and UNCERTAINTY ACP Acid phosphatase total 1-naphthyl phosphate NPP Acid phosphatase, non-prostatic 1-naphthyl phosphate (Inhib.:tartrate) ACP-P Acid phosphatase, prostatic 1-naphthyl phosphate (Inhib.:tartrate) ALB Albumin

More information

The PATH to better cardiac care starts here

The PATH to better cardiac care starts here The PATH to better cardiac care starts here #1 for precision among point-of-care analyzers * Affordable, core-lab quality results in under 17 minutes Test menu: Troponin I, NTproBNP, CK-MB, D-Dimer, hscrp

More information

Laboratory Medicine Standardization Activity in Japan

Laboratory Medicine Standardization Activity in Japan JCTLM 15/11/2005 Sevres, Paris oratory Medicine Standardization Activity in Japan National Institute Metrology of Japan (NMIJ) Koichi Chiba Fujirebio Inc. Katsuhiko Yamamoto University of Tsukuba Katsuhiko

More information

DIAZYME PRODUCT LIST LIST INNOVATIONS IN CLINICAL DIAGNOSTICS

DIAZYME PRODUCT LIST LIST INNOVATIONS IN CLINICAL DIAGNOSTICS DIAZYME PRODUCT LIST LIST PRODUCT 2 14 INNOVATIONS IN CLINICAL DIAGNOSTICS About Diazyme Diazyme Laboratories is a Division of General Atomics located in Poway, California. Diazyme uses its proprietary

More information

Standatrol S-E. 2 niveles. Lyophilized serum for precision control in clinical chemistry

Standatrol S-E. 2 niveles. Lyophilized serum for precision control in clinical chemistry Lot: 1404137860 (Exp.: 2016/04) Level 1: 137860 (Exp.: 2016/04) Level 2: 137860 (Exp.: 2016/04) C Standatrol S-E 2 niveles Lyophilized serum for precision control in clinical chemistry USES Standatrol

More information

CROATIAN SOCIETY OF MEDICAL BIOCHEMISTRY AND LABORATORY MEDICINE

CROATIAN SOCIETY OF MEDICAL BIOCHEMISTRY AND LABORATORY MEDICINE CROATIAN SOCIETY OF MEDICAL BIOCHEMISTRY AND LABORATORY MEDICINE Croatian Centre for Quality Assessment in Laboratory Medicine Dear colleagues, Boskoviceva 18, 10000 Zagreb Croatia Tel/Phone & Fax: +385

More information

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK Biochemistry Department University Hospital of North Durham Durham County Durham DH1 5TW Contact: Dr Tim Lang Tel: +44 (0) 191 333 2694 Fax:

More information

catálogo catalogue

catálogo catalogue catálogo 2010 2011 catalogue Linear Chemicals sl Joaquim Costa, 18 pl.2 08390 Montgat Spain tel. +34 934 694 990 fax. +34 934 693 435 e-mail: info@linear.es 2010 2011 04 Clinical chemistry / Química clínica

More information

Auto HbA1C ANALYZER HbA1LC HPLC 3660

Auto HbA1C ANALYZER HbA1LC HPLC 3660 Turnkey Laboratories Solutions Auto HbA1C ANALYZER HbA1LC HPLC 3660 Viewable Accuracy Real Time Summarized Chromatogram Authentic Results EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES

More information

URYXXON 300 Instrumental evaluation of urine test sticks

URYXXON 300 Instrumental evaluation of urine test sticks URYXXON 300 Instrumental evaluation of urine test sticks MACHEREY-NAGEL URYXXON 300 Instrumental evaluation Boost your lab performance immediate startup one measurement every 8 seconds (400 sticks/h) bar

More information

CALIBRATION SERUM LEVEL 3 (CAL 3)

CALIBRATION SERUM LEVEL 3 (CAL 3) CALIBRATION SERUM LEVEL 3 (CAL 3) CAT. NO. CAL 2351 LOT NO. 709UE SIZE: 20 x 5ml EXP: 2016-12 INTENDED USE For use as a Calibrator in clinical chemistry assays. RANDOX Calibration Sera are based on lyophilised

More information

HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. First HPLC Analyzer to Aid in Diagnosis of Diabetes

HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. First HPLC Analyzer to Aid in Diagnosis of Diabetes HPLC ANALYZER Gold Standard Accuracy by Ion-Exchange HbA1c First HPLC Analyzer to Aid in Diagnosis of Diabetes TOSOH BIOSCIENCE www.tosohbioscience.us HPLC ANALYZER HbA1c analysis in 1.6 minutes Direct

More information

Randox Biosciences Introduction

Randox Biosciences Introduction Sports & Exercise Randox Biosciences Introduction Randox Biosciences is part of Randox Laboratories and is dedicated to advancing scientific discovery, drug development and diagnostics. Spanning four key

More information

Technical Bulletin. Performance Characteristics of the BN ProSpecä System. By Liana Frances Romero, BS, MT(ASCP)

Technical Bulletin. Performance Characteristics of the BN ProSpecä System. By Liana Frances Romero, BS, MT(ASCP) Technical Bulletin Performance Characteristics of the BN ProSpecä System By Liana Frances Romero, BS, MT(ASCP) Introduction The BN ProSpecä System is an automated nephelometry analyzer for in vitro diagnostic

More information

TRACEABILITY and UNCERTAINTY 7

TRACEABILITY and UNCERTAINTY 7 Routine Method COBAS INTEGRA systems Acid phosphatase total 1-naphthyl phosphate Integra 00 plus Acid phosphatase total 1-naphthyl phosphate Acid phosphatase, non-prostatic Integra 00 plus Acid phosphatase,

More information

HUMAN ASSAYED MULTI-SERA - LEVEL 3 (HUM ASY CONTROL 3)

HUMAN ASSAYED MULTI-SERA - LEVEL 3 (HUM ASY CONTROL 3) 0086 HUMAN ASSAYED MULTI-SERA - LEVEL 3 (HUM ASY CONTROL 3) CAT. NO. HE1532 / HS2611 LOT NO. 789UE SIZE: 20 x 5ml / 5 x 5ml EXP: 2019-05 INTENDED USE This product is intended for in vitro diagnostic use

More information

Increasing your Products Shelf Life, Consistency, and Quality.

Increasing your Products Shelf Life, Consistency, and Quality. Increasing your Products Shelf Life, Consistency, and Quality. Q U A R T Z A N A LY T I C S AC Making Science Simple ryst al Fi ltrat ion Com pany Unsaturated and saturated fats, as well as nuts, chocolate,

More information

SydPath Reference Intervals for Clinical Trials (Contract Pathology Unit) Unauthorised Copy

SydPath Reference Intervals for Clinical Trials (Contract Pathology Unit) Unauthorised Copy HAEMATOLOGY APTT 1 150 M 25 35 sec APTT 1 150 F 25 35 sec Basophils Cord 2 weeks M 0.0 0.4 10^9/L Basophils Cord 2 weeks F 0.0 0.4 10^9/L Basophils 2 wks 3 mths M 0.0 0.2 10^9/L Basophils 2 wks 3 mths

More information

The Key to Confidence

The Key to Confidence WITH The Key to Confidence The Key to Confidence More detail, better accuracy, greater confidence The G-scan Brio is a revolutionary MRI approach for all musculoskeletal applications, which allows you

More information

Smart Diagnostics for Point-of-Care!

Smart Diagnostics for Point-of-Care! Smart Diagnostics for Point-of-Care! The one special multi-parameter Point-of-Care (POC) instrument that covers the constantly expanding range of applications with the highest precision. Designed for HbA1c

More information

Evaluation of VACUETTE CAT Serum Fast Separator Blood Collection Tube for Routine Chemistry Analytes in Comparison to VACUTAINER RST Tube

Evaluation of VACUETTE CAT Serum Fast Separator Blood Collection Tube for Routine Chemistry Analytes in Comparison to VACUTAINER RST Tube Evaluation of VACUETTE CAT Serum Fast Separator Blood Collection Tube for Routine Chemistry Analytes in Comparison to VACUTAINER RST Tube Background: Greiner-Bio-One, Austria has been selling plastic evacuated

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION In terms of section 22(2) (b) of the Accreditation for Conformity Assessment, Calibration and Good Laboratory Practice Act, 2006 (Act 19 of 2006), read with sections 23(1),

More information

ICL Integrative Laboratory Services Test Menu Contact ICL Client Care x300

ICL Integrative Laboratory Services Test Menu Contact ICL Client Care x300 Alletess Food Sensitivity Fingerstick 96 Foods IgG with or without Wellness Program 184 Foods IgG with or without Wellness Program Alletess Food Allergy/Sensitivity Serum 96 Foods IgG with or without Wellness

More information