Heflotron" Plus - An enviable asset

Size: px
Start display at page:

Download "Heflotron" Plus - An enviable asset"

Transcription

1 / Heflotron" Plus - An enviable asset

2 Rejlotronw - An enviable asset to test clinical chemistry parameters in primary care settings for daily routine diagnostics in small series or for single determinations... as back-up system in hospitals and private labs... at screening sites... for health check-ups. n p1us Refl otro \ \ Success!... because you impress your patients with rapid test results and an immediate diagnosis... because you have more time for your patients... because your patients like the fact that you don't waste any time deciding what treatment is needed... because your patients are recommending you to others

3 It's so easy and fast......preparation... The Reflotron" Plus system is ready only a few minutes after switching on. In stand-by mode it is READY immediately. Neither reagent preparation nor a calibration procedure is necessary.... Test procedure. Apply 30111capillary blood, venous blood, plasma or serum to test strip. Insert the test strip into the instrument, the flap. close Read the result after 2 to 3 minutes. The result is stored in the memory of the instrument. It can be printed out or can be transmitted to a computer system.

4 Rejlotron - Developed for easy and comfortable handling... Measuring principle: Reflectance measurement based on the colour change in the test strips Measuring temperature: 37.0 C ± O.l C, conversion to 25 C and 30 C possible Display: Alphanumeric - 2 lines of 24 characters each Data interfaces: 5-pin DIN socket as keyboard interface, 1 RS 232 C serial, DB 25 socket for transfer of data to an external computer Time to result: 2-3 minutes/ls-30 tests per hour Integrated printer: Dot-matrix printer for permanent Ambient operating conditions: documenation Temperature: + 15 C to +34 C, rei. humidity: max. 95% Power supply: V AC (± 22%); frequency: 47 Hz to 63 Hz, optional battery operation (10-30 V direct current, e.g. from a car battery) Process control: Text messages in the display guide the user through the process (automatic monitoring of over 50 functions, language selection possible) Dimensions: Approx. 300 x 350 x 210 mm Storage of patient data: Up to 60 results with date, time and patient/sample identification Weight: Approx. 5.3 kg

5 Rejlotron - Covers a wide range of daily routine and emergency testing small sample volume reliable test results comparable with standardised lab methods test-specific information as well as calibration data transmitted automatically to the instrument wide measuring ranges long stability of the test strips even after first opening of the container low-waste Muscle Diseases Anemia Hemoglobin Bilirubin CK Lipid Metabolism Disorders Cholesterol Triglycerides HDL Cholesterol Glucose LDL Cholesterol Bone Diseases Alk. Phosphatase Renal Diseases Liver Diseases GOT, GPT, GGT Bilirubin Alk. Phosphatase Urea Creatinine Hemoglobin Uric Acid K+ Gout Uric Acid Urea Creatinine Glucose Cholesterol Triglycerides Pancreatitis Pancr. Amylase Amylase Diabetes Glucose Triglycerides HDL Cholesterol Creatinine ~O::: ~===;===::::J ~~"~."~"'~'''~H~;;;:'';;. ~''.~ ~ ';;;;.''~. "~.m;;;,";;;:''..::". ==':'JJ':~:2JI:E':::::J::"... ~ For further information.!!.....!... _. &!!.!! ~ please visit us at c......s..s o... 0"""'- ao ao Q ~ " 0_ 4Oc.. TI f P,Olluclo""dlf 6IOo~an~. lan~=v At,. CIII.,. Com~l<t At,uWJ\CIIOC lie""""'" ocr C"dlat,.1<I1f m COlguClII"89ys~m...,... R_oo. R_n_. meet.., 0<,"'91000 Tn'lng F.: Renctrone Oeernew Plus --.~,, ~._ _ _. "'c.. hl.,,7_.....,,- ~ ~,... -~ --

6 Order your Refiotronv Plus today! Instrument REF Reflotron" Plus Reflectance photometer Retlotron" Tests Package size REF Glucose 30 tests Cholesterol 30 tests Triglycerides 30 tests HDL Cholesterol 30 tests GPT (ALT) 30 tests GOT (AST) 30 tests GGT (-y-gt) 30 tests Creatinine 30 tests Urea 15 tests Uric Acid 30 tests K (Postassium) 30 tests Alkal. Phosphatase 30 tests Hemoglobin 30 tests Bilirubin 30 tests CK 15 tests Amylase 15 tests Pancreatic Amylase 15 tests LDL Cholesterol Calculation acc. to Friedewald Reflotron" Controls Package size REF Clean + Check 15 Control test stripsl16 wipes Precinormv U 4x2ml Precinormv HB 4x2ml Precinorrnw HDL 2x 2 mllevel 1, 2x 2 mllevel REFLOTRON and PRECINORM are trademarks of Roche. Diagnostics Roche Diagnostics GmbH Mannheim Germany cc <> <> sq r- r- III co cc Q co Q

Serodos and Serodos plus

Serodos and Serodos plus Design Verification Serodos and Serodos plus Contents 1 Value Adjustment... 2 2 Target Determination... 2 3 Stability... 2 Real-Time Stability... 3 Stability after Reconstitution... 4 Stability after Reconstitution

More information

More to Life. Where research becomes the basis of discovering newer ways of alleviating human suffering and empowering an individual with good health.

More to Life. Where research becomes the basis of discovering newer ways of alleviating human suffering and empowering an individual with good health. More to Life Where research becomes the basis of discovering newer ways of alleviating human suffering and empowering an individual with good health. Meril Diagnostics Emerging from a lineage of successful

More information

CLINICAL CHEMISTRY REAGENTS. Product Profile

CLINICAL CHEMISTRY REAGENTS. Product Profile Product Profile Why Clinical Chemistry Reagents? Quantitative determination of specific analytes associated with various types of disease. Diagnosis Identifying a disease already present Prognosis Forecasting

More information

Front Cover PRICE LIST

Front Cover PRICE LIST Front Cover PRICE LIST w.e.f st July, 0 PACKSIZE KITMRP 9 0 9 0 X0ML X0ML 00ML XML XML XML X00ML XML X0ML 9.00,.00,.00,.00.00 9.00,.00,.00,90.00.00.00,0.00.00,00.00,.00,9.00,.00,9.00 9,.00 9.00.00 AMYLASE-LQ

More information

Reflotron Plus Information Booklet

Reflotron Plus Information Booklet Reflotron Plus Information Booklet Bio-Stat Healthcare Group Pepper Road, Hazel Grove, Stockport, Cheshire SK7 5BW Tel. 0161-483 5884 Fax. 0161-483 5778 Reflotron Information Booklet Rev. No. 1.0 Issue

More information

Chemistry Reference Ranges and Critical Values

Chemistry Reference Ranges and Critical Values Alanine Aminotransferase (ALT, SGPT) 3-9 years 9-18 years 1-9 years 9-18 years 10-30 U/L 10-30 U/L 10-20 U/L Albumin 0-6 days 6 days - 37 months 37 months - 7 years 7-20 years 2.6-3.6 g/dl 3.4-4.2 g/dl

More information

Chemistry Reference Ranges and Critical Values

Chemistry Reference Ranges and Critical Values Alanine Aminotransferase (ALT, SGPT) 3-9 years 9-18 years 1-9 years 9-18 years 10-25 U/L 10-35 U/L 10-30 U/L 10-25 U/L 10-30 U/L 10-35 U/L 10-25 U/L 10-35 U/L 10-25 U/L 10-20 U/L 10-35 U/L Albumin 0-6

More information

Carry-over Evasion List

Carry-over Evasion List Version 22 Note: It is possible that non-roche reagents may cause carry-over interference. Roche is not responsible for any carry-over interference caused by non-roche reagents. Urea and Ammonia should

More information

POC Testing: The New Standard. InnovaStar From DiaSys.

POC Testing: The New Standard. InnovaStar From DiaSys. POC Testing: The New Standard. InnovaStar From DiaSys. Easy to use, superior precision, rapid results: InnovaStar from DiaSys brings POC testing to a whole new level. A fully automatic, compact analyzer

More information

Uni-Asia Scientific Instrument Company Limited. Stanbio Laboratory Product List

Uni-Asia Scientific Instrument Company Limited. Stanbio Laboratory Product List 0130-430 Magnesium LiquiColor Test 0140-050 Sodium Test 0150-250 Calcium (CPC) LiquiColor Test 0153-030 Calcium Standard (10 mg/dl) 0155-225 Calcium (Arsenazo) LiquiColor Test 0160-050 Potassium Test 0210-250

More information

NEW. Fully Automated Solution. Metabolic Disorders Diabetes Vitamin Deficiencies Inflammatory Diseases Clinical Chemistry Specific Proteins TDM DOA

NEW. Fully Automated Solution. Metabolic Disorders Diabetes Vitamin Deficiencies Inflammatory Diseases Clinical Chemistry Specific Proteins TDM DOA NEW FAST & ACCURATE DIAGNOSIS OF: Metabolic Disorders Diabetes Vitamin Deficiencies Inflammatory Diseases Clinical Chemistry Specific Proteins TDM DOA Fully Automated Solution Reliable User-friendly Fast

More information

URYXXON 300 Instrumental evaluation of urine test sticks

URYXXON 300 Instrumental evaluation of urine test sticks URYXXON 300 Instrumental evaluation of urine test sticks MACHEREY-NAGEL URYXXON 300 Instrumental evaluation Boost your lab performance immediate startup one measurement every 8 seconds (400 sticks/h) bar

More information

INDEX PAG CLINICAL CHEMISTRY Enzymes, Substrate, Electrolytes... PAG. 5 - CALIBRATORS CONTROLS... PAG. 6 - ELECTROPHORESIS. PAG.

INDEX PAG CLINICAL CHEMISTRY Enzymes, Substrate, Electrolytes... PAG. 5 - CALIBRATORS CONTROLS... PAG. 6 - ELECTROPHORESIS. PAG. INDEX - CLINICAL CHEMISTRY Enzymes, Substrate, Electrolytes...... - CALIBRATORS CONTROLS..... - ELECTROPHORESIS. - Minipohor 08 - Dedicated Reagents.... - IMMUNOTURBIDIMETRY.... PAG. 1-5 PAG. 5 PAG. 6

More information

Comparison of VACUETTE Heparin Gel Tubes for Common Chemistry Analytes

Comparison of VACUETTE Heparin Gel Tubes for Common Chemistry Analytes Comparison of VACUETTE Heparin Gel Tubes for Common Chemistry Analytes Background: Greiner-Bio-One, Austria has been selling plastic evacuated tubes (VACUETTE ) for venous blood collection since 9. The

More information

GIMA ŠLAPIMO ANALIZATORIAI

GIMA ŠLAPIMO ANALIZATORIAI GIMA ŠLAPIMO ANALIZATORIAI Eil. Nr. 1. Aprašymas 24051 URILYZER 100 URINE ANALYZER - with printer Urilyzer 100 is a small urine test strip reader that offers a broad range of optimized features. The intuitive

More information

Dräger Alcotest Handheld Product Suite

Dräger Alcotest Handheld Product Suite Dräger Alcotest Handheld Product Suite D-7404-2014 Roadside alcohol testing can be challenging and unpredictable. That s why Dräger designed Alcotest handheld breath testers to be accurate and easy to

More information

Optimized for best performance in clinical chemistry testing

Optimized for best performance in clinical chemistry testing Optimized for best performance in clinical chemistry testing System Reagents for Indiko and Konelab clinical and specialty chemistry analyzers Complete system solutions Thermo Scientific system reagents

More information

Excellence and confidence

Excellence and confidence Thermo Scientific System Reagents Fully supported and guaranteed, CE marked system solutions Streamlined supply and support Maximum stability and reduced waste Standardised performance in External Quality

More information

CERTIFICATE OF CONFORMITY

CERTIFICATE OF CONFORMITY TECHEUROPA INSPECTION AND CERTIFICATIONS PRIVATE LIMITED Website: www.tech-europa.com CERTIFICATE OF CONFORMITY Manufacturer Jeev Diagnostics Private Limited #9, 5 th Floor, Gokul Tower, 9 & 10, C.P.Ramasamy

More information

Biocard. 1. Troponin I

Biocard.  1. Troponin I Biocard http://www.anibiotech.fi Biocard Quant Reader is a quantitative desktop reader for all Biocard rapid cardiac tests: Troponin I, Myoglobin, CRP, hscrp, MPO and CK-MB. It has a embedded printer and

More information

Manufacturer Report for Siemens Unassayed Chemistry Lot Exp 30 Jun 2018

Manufacturer Report for Siemens Unassayed Chemistry Lot Exp 30 Jun 2018 Acetaminophen Enzymatic, colorimetric µg/ml.09 0..0.09 0..0 0. 0. 0. 0. 9.. 9.0 0.9.0..9.. Albumin Bromcresol Purple (BCP) g/dl.0 0.0..0 0.00.. 0.0.. 0.09..9 0.0..9 0.0..0 0.0..0 0.0. Alkaline Phosphatase

More information

Questionnaire. Traceability in EQA. Traceability

Questionnaire. Traceability in EQA. Traceability Questionnaire in EQA QUESTIONNAIRE ON TRACEABILITY QUESTIONNAIRE ON TRACEABILITY GENERAL INFORMATION Name EQA organisation Country Specify the total number of measurands in the schemes of your EQA organisation

More information

cobas u 601 urine analyzer Providing precise and secure test results

cobas u 601 urine analyzer Providing precise and secure test results Providing precise and secure test results 1 of 6 Providing precise and secure test results cobas u 601 urine analyzer is a modular, analytical system platform for urine strip testing and features a fully

More information

BLOOD IS COMPLEX ANALYZING IT SHOULDN T BE DxH 500 * *Not available for sale in the U.S.

BLOOD IS COMPLEX ANALYZING IT SHOULDN T BE DxH 500 * *Not available for sale in the U.S. BLOOD IS COMPLEX ANALYZING IT SHOULDN T BE DxH 500 * *Not available for sale in the U.S. Introducing the DxH 500, an Open-vial Hematology System *. Quality 5-part Differential in a Compact Design The first

More information

Abaxis Piccolo xpress TM

Abaxis Piccolo xpress TM Abaxis Piccolo xpress TM A breakthrough in point-of care diagnostics A breakthrough in point of care diagnostics Fast, easy, accurate on-site testing The Piccolo xpress TM is a fully automated system,

More information

Thermo Scientific System Reagents Excellence in Clinical Chemistry

Thermo Scientific System Reagents Excellence in Clinical Chemistry Thermo Scientific System Reagents Excellence in Clinical Chemistry Part of Thermo Fisher Scientific Covering over 150 CE marked products, Thermo Scientific system reagents are specifically developed and

More information

short catalogue diasys diagnostic systems clinical chemistry immunoturbidimetric tests calibrators standards controls supplementary reagents

short catalogue diasys diagnostic systems clinical chemistry immunoturbidimetric tests calibrators standards controls supplementary reagents ::010 ::011 ::012 ::013 ::014 ::015 ::016 ::017 ::018 short catalogue 11 ::026 ::027 ::028 ::029 ::030 ::031 ::032 ::036 ::037 ::038 ::039 ::043 ::044 ::045 clinical chemistry ::048 ::049 immunoturbidimetric

More information

short catalogue clinical chemistry immunoturbidimetric tests calibrators standards controls supplementary reagents instruments Probedruck ::018 ::016

short catalogue clinical chemistry immunoturbidimetric tests calibrators standards controls supplementary reagents instruments Probedruck ::018 ::016 DiaSys_Kurzkatalog_2015_141209 10.12.2014 12:07 Uhr Seite 1 C ::010 ::011 ::012 ::013 ::014 M Y CM MY ::015 CY CMY K ::016 ::017 15 short catalogue ::026 ::027 ::028 ::029 ::036 ::030 ::037 ::018 ::031

More information

External Quality Assessment for Calibration Laboratories in Laboratory Medicine - RELA -

External Quality Assessment for Calibration Laboratories in Laboratory Medicine - RELA - External Quality Assessment for Calibration Laboratories in Laboratory Medicine - RELA - Anja Kessler Bonn, Germany 1 RELA Surveys www.dgkl-rfb.de 2 RELA Annual Process Each participant receives two different

More information

MEMORANDUM. These reference ranges are effective immediately but sample requirements remain unchanged currently.

MEMORANDUM. These reference ranges are effective immediately but sample requirements remain unchanged currently. MEMORANDUM Originating Department Chemical Pathology Issued By: Issued To: Subject: Details: Dr. Shari Srinivasan All Laboratory Service Users Change in Chemical Pathology Analysers Dear Colleague, As

More information

WSLH. Calibration Verification/ Linearity Products. roficiency. esting. Products provided in partnership with:

WSLH. Calibration Verification/ Linearity Products. roficiency. esting. Products provided in partnership with: WSLH PT roficiency esting Calibration Verification/ Linearity Products Products provided in partnership with: www.wslhpt.org 800-462-5261 PTService@slh.wisc.edu General Chemistry Ammonia/Ethanol - 5 x

More information

Glucose analyser GA 3

Glucose analyser GA 3 Glucose analyser GA 3 NEW The GA 3 from KABE LABORTECHNIK for a precise determination of glucose and lactate values Precise, fully automated, quick and economical the GA 3! The GA 3 represents a further

More information

Dräger Alcotest 5510 Alcohol Screening Device

Dräger Alcotest 5510 Alcohol Screening Device Dräger Alcotest 5510 Alcohol Screening Device The Dräger Alcotest 5510 handheld screener provides the quality, accuracy, and reliability that our customers have come to expect from our breath alcohol detection

More information

Polymer Technology Systems, Inc. CardioChek PA Comparison Study

Polymer Technology Systems, Inc. CardioChek PA Comparison Study Polymer Technology Systems, Inc. CardioChek PA Comparison Study Evaluation Protocol: Accuracy Precision Clinical Correlation PTS Panels Lipid Panel Test Strips For Use in Comparisons to a Reference Laboratory

More information

Specimen Collection Requirements

Specimen Collection Requirements The following is a job aid listing the specimen collection requirements for laboratory testing at Colchester East Hants Health Center. Specimens must be accompanied by the Patient Information Form G09.

More information

Specimen Collection Requirements

Specimen Collection Requirements The following is a job aid listing the specimen collection requirements for laboratory testing at Colchester East Hants Health Center. Specimens must be accompanied by the Patient Information Form G09.

More information

Standatrol S-E. 2 niveles. Lyophilized serum for precision control in clinical chemistry

Standatrol S-E. 2 niveles. Lyophilized serum for precision control in clinical chemistry Lot: 1711232000 Level 1: 230680 Level 2: 230700 C Standatrol S-E 2 niveles Lyophilized serum for precision control in clinical chemistry USES Standatrol S-E 2 niveles is adaptable to different uses: -

More information

General Chemistry Scheme Guide

General Chemistry Scheme Guide General Chemistry Scheme Guide Copyright WEQAS. All rights reserved. No part of this document may be reproduced or utilised in any form without permission from WEQAS Contents. Scheme details and repertoire.....

More information

Standatrol S-E. 2 niveles. Lyophilized serum for precision control in clinical chemistry

Standatrol S-E. 2 niveles. Lyophilized serum for precision control in clinical chemistry Lot: 1702210520 Level 1: 201920 Level 2: 201930 C Standatrol S-E 2 niveles Lyophilized serum for precision control in clinical chemistry USES Standatrol S-E 2 niveles is adaptable to different uses: -

More information

Setting of quality standards

Setting of quality standards Setting of quality standards Graham Jones Department of Chemical Pathology St Vincent s Hospital, Sydney AACB ASM Adelaide October 2014 Setting of Quality Standards - 2013 The 2013 QC workshop revealed

More information

BeneCheck BK6-12M. Plus Multi-Monitoring Meter and Strips

BeneCheck BK6-12M. Plus Multi-Monitoring Meter and Strips BeneCheck BK6-12M Plus Multi-Monitoring Meter and Strips The BeneCheck BK6-12M multi-monitoring system is an easy to use, handheld device which allows you to check your Total Cholesterol, as well as Blood

More information

Standatrol S-E. 2 niveles. Lyophilized serum for precision control in clinical chemistry

Standatrol S-E. 2 niveles. Lyophilized serum for precision control in clinical chemistry Lot: 1404137860 (Exp.: 2016/04) Level 1: 137860 (Exp.: 2016/04) Level 2: 137860 (Exp.: 2016/04) C Standatrol S-E 2 niveles Lyophilized serum for precision control in clinical chemistry USES Standatrol

More information

Items in the package:

Items in the package: Intended Use: The EasyLife Hb Monitoring System is designed for in vitro diagnostic use only (external use only), and is suitable for self-testing. The system is for healthcare professionals and persons

More information

AD226 Diagnostic Audiometer

AD226 Diagnostic Audiometer AD226 Technical Specificatons Page 0 Technical Specifications AD226 Diagnostic Audiometer D-0106126-C 2017/11 AD226 Technical Specificatons Page 1 License Overview International configuration AD226 Basic

More information

HemoCue Hb METHOD AND SAMPLE COLLECTION

HemoCue Hb METHOD AND SAMPLE COLLECTION HemoCue Hb 201 + METHOD AND SAMPLE COLLECTION 1. PURPOSE AND SCOPE The purpose of this document is to describe the procedure for performing a Haemoglobin (Hb) test using the HemoCue Hb 201 + analyser.

More information

BS-230. Clinical Chemistry Analyzer

BS-230. Clinical Chemistry Analyzer BS-230 Clinical Chemistry Analyzer Flexible loading: 80 sample positions, Up to 80 reagent positions. Up to (40 fixed + 40 interchangeable) μl minimum reaction volume Disposable Cuvettes to avoid contamination

More information

Adams Memorial Hospital Decatur, Indiana EXPLANATION OF LABORATORY TESTS

Adams Memorial Hospital Decatur, Indiana EXPLANATION OF LABORATORY TESTS Adams Memorial Hospital Decatur, Indiana EXPLANATION OF LABORATORY TESTS Your health is important to us! The test descriptions listed below are for educational purposes only. Laboratory test interpretation

More information

Omnitest : 2013

Omnitest : 2013 ISO 15197: 2013 Omnitest 3 Blood Glucose Monitoring System Omnitest 3 Could it be easier? After strip insertion, Omnitest 3 is ready for the measurement. The code is set automatically. Only 0.3 µl sample

More information

5/6/ :35:00AM 5/6/ :57:28AM 5/6/2017 3:49:09PM A/c Status. Test Name Results Units Bio. Ref. Interval

5/6/ :35:00AM 5/6/ :57:28AM 5/6/2017 3:49:09PM A/c Status. Test Name Results Units Bio. Ref. Interval LL - LL-ROHINI (NATIONAL REFERENCE 136235211 Age Unknown Gender Unknown 5/6/2017 103500AM 5/6/2017 105728AM 5/6/2017 34909M Ref By Final Swasth lus Health Advance anel LIVER & KIDNEY ANEL, SERUM (Spectrophotometry,

More information

DIABETES AND LABORATORY TESTS. Author: Josephine Davis

DIABETES AND LABORATORY TESTS. Author: Josephine Davis DIABETES AND LABORATORY TESTS Author: Josephine Davis LAB TESTS Think twice before you test. What is the reason for testing? Laboratory tests are generally requested in primary care for one of the following

More information

Roche/Hitachi - PreciControl ClinChem Multi 2

Roche/Hitachi - PreciControl ClinChem Multi 2 ATRYP Antitrypsin alpha 1 ERM-DA470k/IFCC 9 136 1.36 1.84 0.0184 GPROT Acid glycoprotein alpha 1 CRM 470 2 90.1 0.901 0.890 0.00890 ACP Acid phosphatase total 1-naphthyl phosphate 0.720 43.1 0.00703 0.421

More information

Multiphasic Blood Analysis

Multiphasic Blood Analysis Understanding Your Multiphasic Blood Analysis Test Results Mon General thanks you for participating in the multiphasic blood analysis. This test can be an early warning of health problems, including coronary

More information

ROTUNDA HOSPITAL DEPARTMENT OF LABORATORY MEDICINE

ROTUNDA HOSPITAL DEPARTMENT OF LABORATORY MEDICINE This active test table informs the user of Biochemistry tests available in house. s referred to other sites are recorded in the Referred Table. Issue date: 4 TH April 2016 Contact Phone Number ext.1345/2522

More information

6/3/2018 9:37:00AM 6/3/2018 9:39:05AM 6/3/2018 1:44:56PM A/c Status. Test Name Results Units Bio. Ref. Interval Bilirubin Direct 0.

6/3/2018 9:37:00AM 6/3/2018 9:39:05AM 6/3/2018 1:44:56PM A/c Status. Test Name Results Units Bio. Ref. Interval Bilirubin Direct 0. LL - LL-ROHINI (NATIONAL REFERENCE 140222511 Age 45 Years Gender Male 6/3/2018 93700AM 6/3/2018 93905AM 6/3/2018 14456M Ref By Final Swasth lus Tax Saver anel 1 LIVER & KIDNEY ANEL, SERUM (Spectrophotometry,

More information

NORMAL LABORATORY VALUES FOR CHILDREN

NORMAL LABORATORY VALUES FOR CHILDREN Pediatric Drug Lookup Normal Laboratory Values for NORMAL LABORATORY VALUES FOR CHILDREN CHEMISTRY Normal Values Albumin 0-1 y 2.0-4.0 g/dl 1 y to adult 3.5-5.5 g/dl Ammonia Newborns 90-150 mcg/dl 40-120

More information

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors VITAL SIGNS MONITORING RVS-100/200 ri-vital Vital Signs Patient Monitors RVS-100 ADVANCED VITAL SIGNS MONITOR The RVS-100 is an advanced vital signs monitor which offers pulse oximetry, blood pressure

More information

PRICE LIST RELIABLE ACCURATE COST EFFECTIVE. American Technology Made in India For India. W.E.F April 2018

PRICE LIST RELIABLE ACCURATE COST EFFECTIVE. American Technology Made in India For India. W.E.F April 2018 PRICE LIST W.E.F April 2018 RELIABLE ACCURATE COST EFFECTIVE American Technology Made in India For India +91-44-22541131 www.athenesedx.com info@athenesedx.com Code OnSite Rapid Tests R0061C R0062C R0062C

More information

2016 PRICE LIST All Prices Effective January 1, 2016 through December 31, 2016 Ex Works: Boerne, Texas

2016 PRICE LIST All Prices Effective January 1, 2016 through December 31, 2016 Ex Works: Boerne, Texas EKF Diagnostics dba Stanbio Laboratory 1261 North Main Street Boerne, Texas 78006 www.stanbio.com Orders: Toll-free: 1-800-531-5535 Fax (830) 249-0851 orders@stanbio.com 2016 PRICE LIST All Prices Effective

More information

Why do we need SD LipidoCare?

Why do we need SD LipidoCare? SD Biosensor, Inc. Innovative Global Leader of In Vitro Diagnostics Total supplier of Blood Glucose Monitoring System and Lipid Analyzer System in vitro diagnostics test kits for Point of Care Testing

More information

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard

GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER. Setting The Clinical Standard GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER GSI TYMPSTAR PRO CLINICAL MIDDLE-EAR ANALYZER New Standard for Clinical Impedance The GSI TympStar Pro is setting the clinical standard for performing a full

More information

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System

GlucCell TM SYSTEM USER S GUIDE Ver 2.1 CELL CULTURE GLUCOSE METER. Important Information. Intended Use. Caution. About the System GlucCell TM SYSTEM USER S GUIDE Ver 2.1 Intended Use The GlucCell TM Glucose Monitoring System (The GlucCell TM System) is designed to quantitatively measure the concentration of glucose during cell culture.

More information

Evidence Based Commutability: Bias 2 Study. Janice Gill Manager RCPAQAP Chemical Pathology Adelaide SA

Evidence Based Commutability: Bias 2 Study. Janice Gill Manager RCPAQAP Chemical Pathology Adelaide SA Evidence Based Commutability: Bias 2 Study Janice Gill Manager RCPAQAP Chemical Pathology Adelaide SA Australian Bias Studies conducted by Gus Koerbin, ACT Pathology on behalf of AACB Harmonisation Committee

More information

ENROLLMENT CONFIRMATION

ENROLLMENT CONFIRMATION Step 1: Please review the Facility/Contact information. If any of the information is incorrect, please make the appropriate changes below: Facility/Contact Phone: (850)474-3660 Fax: (850)474-3659 6431

More information

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY ASSAY AND INSTRUMENT COMBINATION TEMPLATE

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY ASSAY AND INSTRUMENT COMBINATION TEMPLATE A. 510(k) Number: k100322 510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY ASSAY AND INSTRUMENT COMBINATION TEMPLATE B. Purpose for Submission: Clearance of a new device C. Measurand: Whole

More information

Lab Values Explained. working at full strength. Other possible causes of an elevated BUN include dehydration and heart failure.

Lab Values Explained. working at full strength. Other possible causes of an elevated BUN include dehydration and heart failure. Patient Education Lab Values Explained Common Tests to Help Diagnose Kidney Disease Lab work, urine samples and other tests may be given as you undergo diagnosis and treatment for renal failure. The test

More information

888/890 Enter the Titrando world

888/890 Enter the Titrando world 888/890 Enter the Titrando world 2 888 Titrando potentiometric titrator 890 Titrando Karl Fischer titrator Touch Control with large color screen Titration software PC Control or tiamo TM for operation

More information

TYMP Technical data. at 85, 95 und 105 db HL. 2. detailed display symbols

TYMP Technical data. at 85, 95 und 105 db HL. 2. detailed display symbols TYMP 4000 With the HOMOTH Tymp 4000 it is possible to do a full automatic impedance measurement within a few seconds. All functions, as well as curves and data are presented at a LCD-display. Herewith

More information

15/9/2017 4:23:00PM 15/9/2017 4:26:06PM 20/9/2017 4:58:24PM A/c Status. Test Name Results Units Bio. Ref. Interval < >40.00 mg/dl <150.

15/9/2017 4:23:00PM 15/9/2017 4:26:06PM 20/9/2017 4:58:24PM A/c Status. Test Name Results Units Bio. Ref. Interval < >40.00 mg/dl <150. Lab No 135091258 Age 30 Years Gender Male 15/9/2017 42300M 15/9/2017 42606M 20/9/2017 45824M Ref By UNKNWON Final Test Results Units Bio Ref Interval SWASTH LUS HEALTH ADVANCE ANEL LIID ROFILE, BASIC,

More information

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa CARE OF PATIENT POLICY & PROCEDURE Policy Number: 4:10 Subject: Policy: Glucose Monitoring (Accuchek) Nursing department staff and laboratory staff

More information

Community health day. General Robert H. Reed Recreation Center 800 Gabreski Lane, Myrtle Beach Friday, May 11 7:30-10:30 a.m.

Community health day. General Robert H. Reed Recreation Center 800 Gabreski Lane, Myrtle Beach Friday, May 11 7:30-10:30 a.m. Community health day General Robert H. Reed Recreation Center 800 Gabreski Lane, Myrtle Beach Friday, May 11 7:30-10:30 a.m. Health screenings to be offered include: Chemistry profile...$20 TSH (thyroid

More information

Alere Technologies GmbH

Alere Technologies GmbH Alere Technologies GmbH Mobile Smart Instruments for Automated Image Analysis and Point of Care Diagnosis April 2011 Alere Technologies GmbH Alere Technologies GmbH Based in Jena, Thuringia, Germany ~300

More information

TEST LIST SAMPLE REQUIREMENT. 1 ml serum None

TEST LIST SAMPLE REQUIREMENT. 1 ml serum None ALBUMIN TEST NAME ALKALINE PHOSPHATASE ALLERGY PROFILE, FOOD 30 allergens ALLERGY PROFILE, INHALANT 30 Allergens ALT AMYLASE ANA ANTI- TG ANTI-GLIADIN IGG ANTI-GLIADIN IGA ANTI-HBS ANTI-HCV ANTI-TPO APOLIPOPROTEIN

More information

Quantitative Measurement of Emergency Biomarkers in Parallel

Quantitative Measurement of Emergency Biomarkers in Parallel Point-of-Care Immunoassay Analyzer Quantitative Measurement of Emergency Biomarkers in Parallel Troponin I, Myoglobin, CK-MB, D-Dimer, NTproBNP, hscrp Results in 17 minutes Direct measurement from whole

More information

Mission Hb accurately detects both

Mission Hb accurately detects both Mission Digital Hb-Testing System: Save Cost by testing 2- Parameters with Single Strip real time ie: i.e: Hemoglobin & Hematocrit-[PCV]. Presented By : Remedy Healthcare Private Limited, New Delhi, [INDIA].

More information

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa

MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa MARSHALLTOWN MEDICAL & SURGICAL CENTER Marshalltown, Iowa CARE OF PATIENT POLICY & PROCEDURE Policy Number: 4:10 Subject: Policy: Glucose Monitoring (Accuchek) Nursing department staff and laboratory staff

More information

QUALITROL 2H Insert. 01 Inglês - Ref.: 72. Ref.:72. Precautions and warnings

QUALITROL 2H Insert. 01 Inglês - Ref.: 72. Ref.:72. Precautions and warnings QUALITROL 2H Insert Ref.:72 Lot 6002 Expiration 2019/08/23 Precautions and warnings Qualitrol 2H is for in vitro diagnostic use only. Attention. It is suggested to verify carefully if the lot number pressed

More information

Evaluation of VACUETTE CAT Serum Fast Separator Blood Collection Tube for Routine Chemistry Analytes in Comparison to VACUTAINER RST Tube

Evaluation of VACUETTE CAT Serum Fast Separator Blood Collection Tube for Routine Chemistry Analytes in Comparison to VACUTAINER RST Tube Evaluation of VACUETTE CAT Serum Fast Separator Blood Collection Tube for Routine Chemistry Analytes in Comparison to VACUTAINER RST Tube Background: Greiner-Bio-One, Austria has been selling plastic evacuated

More information

Stability of VACUETTE Lithium Heparin Separator tubes with modified centrifugation conditions

Stability of VACUETTE Lithium Heparin Separator tubes with modified centrifugation conditions Stability of VACUETTE Lithium Heparin Separator tubes with modified centrifugation conditions Background: Greiner-Bio-One, Austria has been selling plastic evacuated tubes (VACUETTE ) for venous blood

More information

HEALTH SCREEN CARE. VIGNE Healthcare provides a comprehensive Health Screening Package of EXCLUSIVE HEALTH SCREENING EXPERIENCE

HEALTH SCREEN CARE. VIGNE Healthcare provides a comprehensive Health Screening Package of EXCLUSIVE HEALTH SCREENING EXPERIENCE HEALTH SCREEN CARE VIGNE Healthcare provides a comprehensive Health Screening Package of Silver Gold Platinum Cancer EXCLUSIVE HEALTH SCREENING EXPERIENCE Meet & Greet Medical Review with Doctor Appointment

More information

User Manual second language

User Manual second language User Manual second language GlucoTel Blood Glucose Monitoring and Diabetes Management System must be used with cell phones that have: Table of contents 2 3 Introduction 4 Bluetooth Wireless Technology

More information

The analytical phase

The analytical phase The analytical phase Result interpretation Test request Result Sampling Black box: the lab ANALYTICAL PHASE The CASE Uncle Pete, 67 years old Marked abdominal pain 8 pm, ED Acute abdomen? Assessment (+

More information

Fullerton Healthcare Screening Centres

Fullerton Healthcare Screening Centres Fullerton Healthcare Screening Centres Fullerton Healthcare Screening Centre @ Ngee Ann City The Penthouse, #26-02 Ngee Ann City Tower B, 391B Orchard Road, Singapore 238874 Operating hours: Monday - Friday

More information

Dear HighQ Check System Owner :

Dear HighQ Check System Owner : Dear HighQ Check System Owner : Thank you for purchasing the HighQ Check Blood Glucose Monitoring System. This manual provides important information to help you to use the system properly. Before using

More information

1. Calibra - H - Store at 2-8 ºC.

1. Calibra - H - Store at 2-8 ºC. CALIBRA H Insert Ref.:80 Lot Expiration Calibrator Attention. It is suggested to verify carefully if the lot number printed in this insert corresponds to the lot on the bottle label. Intended use. is a

More information

PRODUCTS FOR EXPORT 2018

PRODUCTS FOR EXPORT 2018 PRODUCTS FOR EXPORT 2018 MEDICON HELLAS SA 5-7 Melitona st., 153 44 Gerakas, Attiki, Greece - Tel.:+30 210 6606000 FAX:+30 210 6612666 e-mail:diag@mediconsa.com, http://www.mediconsa.com General Electronic

More information

ADPedKD: detailed description of data which will be collected in this registry

ADPedKD: detailed description of data which will be collected in this registry ADPedKD: detailed description of data which will be collected in this registry I. Basic data 1. Patient ID: will be given automatically 2. Personal information - Date of informed consent: DD/MM/YYYY -

More information

OIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION

OIML R 122 Annex C RECOMMENDATION. Edition 1999 (E) ORGANISATION INTERNATIONALE INTERNATIONAL ORGANIZATION INTERNATIONAL RECOMMENDATION OIML R 122 Annex C Edition 1999 (E) Equipment for speech audiometry Annex C Test report format Appareils pour l audiométrie vocale Annexe C Format du rapport d essai OIML R

More information

Hamilton Regional Laboratory Medicine Program

Hamilton Regional Laboratory Medicine Program Created: April 2002 of Review: February 2004 of Review: June 2006 of Review: July 2007, St. Joseph s Healthcare went live with Meditech as of June18, 2007. of Review: August 2009 of Review: December 2011;

More information

Thermo Scientific Konelab System Reagents For convenient and reliable analysis

Thermo Scientific Konelab System Reagents For convenient and reliable analysis Thermo Scientific Konelab System Reagents For convenient and reliable analysis Part of Thermo Fisher Scientific Thermo Scientific Konelab system reagents ensure the high quality analysis results Easy-to-use

More information

Total Cost of Ownership (TCO): An evidence-based approach to compare laboratory equipment

Total Cost of Ownership (TCO): An evidence-based approach to compare laboratory equipment Total Cost of Ownership (TCO): An evidence-based approach to compare laboratory equipment P.C.G. Gontard 1, L.I. Stankevich 1, B.G. Gorodetsky 1 SUMMARY Clinical laboratories across the globe operate in

More information

What Does My Blood Test Mean

What Does My Blood Test Mean What Does My Blood Test Mean CBC with Differential This means that your doctor wants to know the amounts and proportions among the various components of your blood, explained below. The term differential

More information

SartoPac Systems Average weight control of prepackages with Sartorius: Fast and effective for reliable product control

SartoPac Systems Average weight control of prepackages with Sartorius: Fast and effective for reliable product control SartoPac Systems Average weight control of prepackages with Sartorius: Fast and effective for reliable product control SartoPac Basic: easy, fast, reliable SartoPac Basic from Sartorius offers you a compact

More information

3 Linearity and Detection Limit Linearity Detection limit... 4

3 Linearity and Detection Limit Linearity Detection limit... 4 Design Verification liquicolor 1 Introduction... 2 2 Imprecision, Reproducibility... 2 2.1 Data from internal study... 2 2.2 Date from external study (Cholesterol Reference Method Laboratory Network)...

More information

INTRO SAFETY INFORMATION GENERAL INFORMATION TESTING PREANALYTICAL PHASE CHECKINGS RUNNING THE TEST ALTERNATIVE SITES MEMORY

INTRO SAFETY INFORMATION GENERAL INFORMATION TESTING PREANALYTICAL PHASE CHECKINGS RUNNING THE TEST ALTERNATIVE SITES MEMORY 04 12 30 60 66 72 INTRO SAFETY INFORMATION GENERAL INFORMATION THE LUX SYSTEM GETTING TO KNOW THE SYSTEM SETTING THE SYSTEM TESTING PREANALYTICAL PHASE CHECKINGS RUNNING THE TEST ALTERNATIVE SITES MEMORY

More information

Daily Quality Control Calibration Verification / Linearity. Quality control made easy. Product Information

Daily Quality Control Calibration Verification / Linearity. Quality control made easy. Product Information Daily Quality Control Calibration Verification / Linearity Quality control made easy. Product Information AUDIT MicroControls Making life in the lab easier. AUDIT provides value to customers through high-quality

More information

Tips for Training New Customers

Tips for Training New Customers Tips for Training New Customers Good Habits: Test Strips Recap vial immediately and tightly after removing a single test strip. Never remove the desiccant from the vial. Do not lay test strips out ahead

More information

10 Essential Blood Tests PART 1

10 Essential Blood Tests PART 1 Presents 10 Essential Blood Tests PART 1 The Blood Chemistry Webinars With DR. DICKEN WEATHERBY Creator of the Blood Chemistry Software Essential Blood Test #1: Basic Chem Screen and CBC http://bloodchemsoftware.com

More information

Dear Prodigy System Owner:

Dear Prodigy System Owner: User's Manual Dear Prodigy System Owner: You have chosen one of the best blood glucose monitoring systems available. This booklet has important information about the system. Please read it carefully. Your

More information

Authorised: JSWoodford, Lead of Speciality. Biochemistry Reference Intervals, October Page 1 of 5

Authorised: JSWoodford, Lead of Speciality. Biochemistry Reference Intervals, October Page 1 of 5 AFP All All < 15 ug/l Albumin All 0-3M 25-40 g/l Albumin All 3-12M 32-45 g/l Albumin All 1-70Y 34-48 g/l Albumin All >70Y 32-46 g/l Alk Phos All 0-10Y 80-350 U/L Alk Phos M 10-14Y 45-400 U/L Alk Phos F

More information