1 Página 1 de 6 NeuroGuide EEG and QEEG Analysis System NeuroGuide the most informative and comprehensive Conventional EEG and QEEG analysis system available. Modern and simple to use Windows Functions provide for Automatic Artifact Rejection, Dynamic FFTs with Comparisons to FFT Lifespan Eyes Open and Eyes Closed Norms covering the age from Birth to 82 years of age. NeuroGuide includes re-montaging to Average Reference or reference free Current Source Density (CSD) or Bipolar Montages, JTFA Instantaneous Power, Coherence, Phase Differences, Burst Metrics and Phase Reset and Bi- Spectral Analyses. NeuroGuide is also designed for use with the LORETA Key Institute Source Localization software for registration with the Talarich MRI Atlas from the Montreal Neurological Institute. NeuroGuide provides tab delimited output files of the edited EEG and the analyses that can be imported into any statistical package or database management system, NeuroGuide includes a TBI & LD discriminant functions, as well as an integrated statistical package as well as predictions of neuropsychological test scores using the Brain Performance Index. NeuroGuide Dynamic Editing Window. Split-Half Reliability and FFT Normative Comparisons of Selected Segments Reduces Artifact Easy KEY Inst. LORETA Integration of Selected EEG Segment or the Artifact Free Record Used for QEEG Report Writing UNIQUE FEATURES Lifespan Normative Comparisons (N = 625): Rel. Power, Abs. Power, Power Ratios, Coherence, Phase and Amp. Asymmetry. Automatic Artifact Rejection with Manual Editing Capability. Multiple EEG File Imports (Lexicor, NeuroScan, EDF, Cadwell, ASCII, Mindset, Mitsar, XLTEK, DeyMed, BrainMaster & others) Instantaneous Split-Half Reliability and test re-test reliability of Selected EEG Segments. Dynamic and Flexible FFT and Normative Comparisons in the Editing Mode. Eyes Open and Eyes Closed Lifespan Norms for Linked ears, average ref. and Current Source Density (CSD) and any bipolar combination of the 10/20 system Re-Montage to any Reference Arrangement, e.g., Average reference or Current Source Density (CSD) Export to the Key Institute LORETA equations and the Montreal Neurological MRI Database (standard in NeuroGuide). Time domain Output Files Formatted for Easy Import to LORETA Key Inst. NeuroGuide Color Bar Graphs of the Direction and Magnitude of EEG Change Required to Normalize the EEG using EEG Biofeedback EEG Coherence and EEG Phase Raw Values and Z Score Normative Comparisons Birth to 82 Years Tab Delimited Output Files for easy importing into statistical programs and database management systems. NeuroStat package for computing paired t-tests, ANOVA for pre vs. post treatment analysis as well as group comparisons (add on to the base price). NeuroBatch programs for automatic processing of large numbers of EEG files (add on to the base price). Raw or Edited EEG Printouts of Any Montage for Conventional EEG Analyses FFT using a 0.5 Hz resolution and 1 Hz Color Maps from 0 to 50 Hz Export edited EEG in Lexicor file format and ASCII FFT Normative Power Ratios, including Z scores for Theta/Hi-Beta, Alpha/Hi-Beta & lo-beta/hi-beta frequency bands Mild Head Injury Discriminant Function and TBI EEG Severity Index (add on to the base price) Learning Disability Discriminant Function (add on to the base price) LORETA normative databases of linked ears, average reference, eyes open and eyes closed - birth to 82 years of age (add on to the base price). LORETA source correlations to evaluate dynamic connectivity Brain Performance Index Prediction of Neuropsychological test scores with a 95% confidence band and including Full Scale IQ, Verbal I.Q. and Performance I.Q. (add on to the base price) JTFA for Instantaneous power, coherence, phase and amplitude asymmetry. JTFA feature detection to detect brain state changes such as drowsiness, sleep and spike & waves. A built in Help manual including tutorials. 24 channel Mindset EEG acquisition (add on to the base price). EEG Burst Metrics
2 Página 2 de 6 Cross-Spectra power, co-spectrum and quad-spectrum for in-phase and out-of-phase EEG analyses Complete 171 channel combination topographic maps Phase Reset and Phase and Frequency Locking measures Time Domain 3-Dimensional Source Localization for spike and wave and other conventional EEG analyses Bi-Spectral Analyses including Log-Log plots of the spectrum and 1/f distributions Up to 128 channel import capacity (128 channels are customized depending on labeling and channel order us at qeeg@appliedneuroscience.com) Real-Time Feedback Between Reliable Artifact Free EEG and the QEEG Re-Montage NeuroGuide Window 85 channels is standard with custom 128 channel imports. You can Select or Create any Montage With Nearly Instant Screen Update Displays and Real-Time Comparisons to Norms Eyes Open & Eyes Closed LifeSpan Norms, Birth to 82 yrs. For Linked Ears, Ave. Reference and Current Source Density (CSD) Standard Features of NeuroGuide Deluxe (Basic) Including LifeSpan Norms EEG Coherence, Phase, Amp. Asym., Rel. Power, Power Ratios Eyes Closed LifeSpan Norms, Dynamic Split-Half Reliability, Dynamic FFT Editing, Automatic Artifact Rejection, Outputs to be used for LORETA 3D Localization, Launch the Key Institute LORETA Viewer, LORETA normative database (birth to 82 years), Tab Delimited Output, Conventional EEG Print Outs, Color Bar Graphs for Minimization of Z Scores, Eyes Open and Eyes Closed Linked Ears, Average Reference and Current Source Density Norms (i.e., Laplacian Norms), Lexicor Export, ASCII Export and multiple EEG file import, EEG burst metrics, time domain LORETA Z-Score tables and connection maps for Coherence, Phase, Asymmetry, Relative Power. Tab Delimited Raw-Score and Z-Scores Exportable to Excel, Systat, SPSS and all Database Management programs. Topographic maps for Raw-Score and Z-Score Relative Power in 4 frequency bands Topographic maps for Absolute and Relative Power Band Ratios, including Gamma frequencies (δ/θ, δ/α, δ/β; δ/γ, θ/α, θ/β, θ/γ, α/ β, α/γ, β/γ). FFT Absolute and Relative Power in Tab Delimited Format Split-Half Reliability Values for Each Channel and an Average Reliability Score all in Tab Delimited Format
3 Página 3 de 6 FFT Absolute and Relative Power in 0.5 Hz resolution from 0 to 50 Hz Color Bar Graphs of Raw Scores and Z scores Showing how much the EEG must change so that the Z Score = 0 1 Hz Topographic Color Maps, from Delta to the Gamma Frequency Band including and Absolute Power and Relative Power Z scores ASCII EEG Export and ASCII Digital EEG Printout as well as Export in Lexicor file format Multiple EEG file import capabilities, e.g., ASCII, Lexicor, NeuroData, NeuroScan, Mindset, NeuroGuide, Mitsar, EDF, BrainMaster, Capscan, Cadwell JTFA instantaneous power, coherence, phase and amplitude asymmetry Import up to 128 channels (128 channel import customized to the users labeling and channel order) JTFA feature detection to identify deviant EEG events and brain state changes such as drowsiness and sleep LORETA current source analyses using the Key Inst. LORETA program LORETA source correlation analyses to evaluate ROI coupling Flexible report generator with adjustable color schemes and Z score ranges First and second derivatives of the EEG time series Export of JTFA values and derivates Flexible export and print capabilities of the EEG traces EEG Burst Metrics Time Domain Source Localization for conventional EEG analysis Event markers with flexible sorting routines NeuroGuide Seamlessly Integrates to TBI and Learning Disability (LD) Discriminant Functions and Correlations with Neuropsychological Tests (purchased as an add on to the basic system) NeuroGuide s NeuroStat ($600 Add On) Seamlessly Integrates Dedicated Comparative Statistics EEG Pre vs. Post Treatment or Beginning Session vs. End of Session EEG and other comparisons
4 Página 4 de 6 Scientific Publications That NeuroGuide is Based On: EEG and Clinical Neurophysiol., 64: , 1986; Science, 236: , 1987; EEG and Clinical Neurophys., 73: , 1989; Journal of Neuroimaging, 5, 35-45, 1995; J. Neurotrauma, 14: 1-14, 1997; NeuroImage, 8(4), , NeuroImage, 7: , 1998; Brain Injury, 12: 13-21, 1999; J. Neuropsychiatry and Clin. Neuroscience 13(1): 77-87, 2001; Int. J. of Neuroscience, 107: , 2000; Clinical Neurophysiology, 112: , 2001; J. of Neurotherapy, 7(3/4): , 2003; Clinical Neurophysiology, 36(2): , 2005; Human Brain Mapping, 28(2): , 2007; Clinical EEG and Neuroscience, 38(1): 35-48, 2007; Human Brain Mapping, Jan. 24, Price and How To Order PACKAGE TYPE (INTRODUCTORY OFFER) PART NO. PRICE NEUROGUIDE DELUXE (BASIC) EEG REVIEW AND NG-1 LifeSpan Normative database Eyes Open & Included Closed FFT and Eyes Closed Birth to 82 years, Automatic artifact rejection, Launch LORETA Viewer in NeuroGuide Amplifier imports include: Lexicor NRS-24, (Basic) NeuroNavigator NeuroScan, Misar, NeuroData, Cadwell MindSet, BrainMaster & CapScan, XLTEK, NeuroPrax, etc. A single Mild Head Injury Discriminant Function and TBI-1 TBI Severity Index or LD Discriminant and Severity LD-1 Index =. Two Discrimiant Functions and severity indexes as a package =. Purchase one discriminant function for
5 Página 5 de 6 and then upgrade to a second for another LORETA Current Density Normative Database LOR-1 Birth to 82 years of Age LORETA 3D Source Correlation Normative Database Birth to 82 years of Age SC-1 * NeuroBatch Automatic Batch analysis software NB-1 NeuroStat An Integrated QEEG Statistics Package NS-1 Brain Performance Index Predict BPI-1 Connectivity Suite (contact dealer for pricing) CS-1 Dynamic Bi-Spectral Analyses (call) BS-1 NeuroGuide for BrainMaster (1 to 4 channels) = $1,200 NGBMr-1 (not an add on) 2 channel Z Score Biofeedback = call DLL-2 4 channel Z Score Biofeedback = call 19 Channel Z Score Biofeedback = call DLL-4 DLL-19 EEG Acquisition as an Add On Module inside of NeuroGuide (Neuropulse or Discovery or Deymed) 19 channel Surface EEG Biofeedback of Z scores. Includes power, coherence, phase, amplitude asymmetry, phase reset, Laplacian, Linked Ears & Ave. Reference. Also Includes a Symptom Check list + Surface EEG Z Scores to Inform Protocol Selections 19 channel Surface EEG Biofeedback of Z scores Includes all of NF1 + LORETA Z Scores to Inform Protocol Selections (must also purchase NF1 (NF1 + NF2) 3-Dimensional LORETA Z Score NeuroImaging Real- Time Brodmann Area Z scores, Functional Module Z Scores, Default Brain Z Scores. Includes a Symptom Check list + Surface EEG Z Scores + LORETA Z Scores to Inform Protocol Selections. Must also purchase NF1 & NF2 before purchase of NF3 (Total package of NF1 + Nf2 + NF3 = $5,000) Symptom Check List NF Protocol Generator add on (independent of NF1 NF3). Generates NF protocols based on qeeg analyses that can be exported. NP1, Disc1 & Dey1 NF1 NF2 NF3 SCL1 NeuroGuide EEG Viewer (Standalone EEG Import, Edit V1 Standalone EEG Acquisition (not an add on to A1 Neuroguide). Only provides for acquisition and saving of EEG data * Prices do not include costs for shipping and handling or sales tax, where applicable Ten month payment plan at 0% interest is Possible Call For further information: Call: (727) ; Fax: Write to: Applied Neuroscience, Inc th Terrace Drive Redington Shores, Fl Or qeeg@appliedneuroscience.com NeuroGuide s operates as a "Library function" for information retrieval and analysis and as an "Accounting and Communications" function by accessing a table of age matched means and standard deviations from an approximate Gaussian Distribution and computing age matched Z scores. There is no intended use for NeuroGuide to provide a medical diagnosis. A trained and qualified person is
6 Página 6 de 6 required to edit the NeuroGuide EEG samples and to interpret the numbers based on their competence and training. NeuroGuide should serve only as an adjunct or in combination to other information that the clinician may use to render a clinical judgment. FDA 510k indications for use are by qualified medical or clinical professionals for the statistical evaluation of the human electroencephalogram (EEG) and competent students and scientists for research purposes.
Clinical Validation of the NeuroGuide QEEG Normative Database. Phase Reset Duration Means. abs(out-phase) Cross Spectral Power. Burst Amplitude Means
1.000 0.900 Clinical Validation of the NeuroGuide QEEG Normative Database Multiple R 0.800 Correlation Coefficient 0.700 0.600 0.500 0.400 0.300 0.200 0.100 0.000 PLATE 2.6 Phase Difference Coherence Phase
More informationHistory of NeuroGuide
1 History of NeuroGuide Robert W. Thatcher, Ph.D. March 21, 2019 1- The central and binding idea of NeuroGuide 1.0 is conventional EEG and qeeg (quantitative electroencephalography) on the same screen
More information4-CHANNEL Z-SCORE NEUROFEEDBACK: A SINGLE CASE STUDY
Introduction 4-CHANNEL Z-SCORE NEUROFEEDBACK: A SINGLE CASE STUDY Nancy Wigton, M.A., LPC, BCIA-EEG, QEEG-T Applied Neurotherapy Center - Scottsdale, Arizona - www.appliedneurotherapy.com 08-29-2008 In
More informationHuman Brain Institute Russia-Switzerland-USA
1 Human Brain Institute Russia-Switzerland-USA CONTENTS I Personal and clinical data II Conclusion. III Recommendations for therapy IV Report. 1. Procedures of EEG recording and analysis 2. Search for
More informationEEG Changes (Research Abstracts)
EEG Changes (Research Abstracts) Kennerly, Richard. QEEG analysis of cranial electrotherapy: a pilot study. Journal of Neurotherapy (8)2, 2004. Presented at the International Society for Neuronal Regulation
More informationNortheast Center for Special Care Grant Avenue Lake Katrine, NY
300 Grant Avenue Lake Katrine, NY 12449 845-336-3500 Information Bulletin What is Brain Mapping? By Victor Zelek, Ph.D., Director of Neuropsychological Services Diplomate, National Registry of Neurofeedback
More informationNeuroLink by Applied Neuroscience, Inc. Help Manual Applied Neuroscience, Inc. Applied Neuroscience, Inc.
NeuroLink by Applied Neuroscience, Inc. Help Manual Applied Neuroscience, Inc. 8200 Bryan Dairy Road, Suite 315 Largo, FL 33777-1355 For More Information Contact: info@anineurolink.com For Support Contact:
More informationNeurotechnology for Special Needs Children
ISSN 4-956 (Print) ISSN -849 (Online) Sep Dec 5 Neurotechnology for Special Needs Children Norsiah Fauzan Faculty of Cognitive Science and Human Development, Universiti Malaysia Sarawak Abstract This paper
More informationBRAIN FUNCTION INDEX
BRAIN FUNCTION INDEX Thatcher, R. W., North, D. M., Biver, C. J. and Zhou, L. EEG and NeuroImaging Laboratory, Applied Neuroscience Research Institute. St. Petersburg, Fl Send Reprint Requests To: Robert
More informationJonathan E. Walker MD a & Joseph Horvat PhD a a. Neurotherapy Center of Dallas Published online: 18 May 2010.
Journal of Neurotherapy: Investigations in Neuromodulation, Neurofeedback and Applied Neuroscience Is It Better to Train Power First or Coherence First? Jonathan E. Walker MD a & Joseph Horvat PhD a a
More informationElectroencephalography System
Electroencephalography System POWERFUL SUPPORT TOOL FOR BRAIN DIAGNOSTICS WORLDWIDE It's a pleasure to help you with your scientific work and patient's healthcare needs FDA 510k: K143233 (USA) eeg routine
More informationProcessed by HBI: Russia/Switzerland/USA
1 CONTENTS I Personal and clinical data II Conclusion. III Recommendations for therapy IV Report. 1. Procedures of EEG recording and analysis 2. Search for paroxysms 3. Eyes Open background EEG rhythms
More informationEEG Biofeedback Training Using Live Z Scores and a Normative Database
EEG Biofeedback Training Using Live Z Scores and a Normative Database Thomas F. Collura, Ph.D., BrainMaster Technologies, Inc. Robert W. Thatcher, Ph.D., Applied Neurosciences, Inc. and University of South
More informationEvaluation and Validity of a LORETA Normative EEG Database
Published in Clin EEG Neurosci. 2005 Apr;36(2):116-22. Evaluation and Validity of a LORETA Normative EEG Database Thatcher, R.W. (Ph.D.) 1,2, North, D.(M.S.) 1 and Biver, C. (Ph.D.) 1 NeuroImaging Labortory,
More informationExploratory Investigation into Mild Brain Injury and Discriminant Analysis with High Frequency Bands (32-64 Hz)
Exploratory Investigation into Mild Brain Injury and Discriminant Analysis with High Frequency Bands (32-64 Hz), Brain Injury, August,1999, 477-488 Exploratory Investigation into Mild Brain Injury and
More informationQuantitative EEG Analyses
Applied Neuroscience, Inc. 7985 113 th Street, Suite #210 Phone 727-244-0240 Seminole Fax 727-392-1436 Florida, 33772 email qeeg@appliedneuroscience.com Quantitative EEG Analyses PATIENT INFORMATION RECORDING
More informationBCIA NEUROFEEDBACK CERTIFICATION PROGRAM
BCIA NEUROFEEDBACK CERTIFICATION PROGRAM Instructor: Cynthia Kerson, PhD (26 BCIA F2F Hours 10 Self-paced Hours Accredited Instruction) Level: Introductory to Intermediate Practice Gap: Neurofeedback is
More informationEEG Biofeedback Case Studies Using Live Z Score Training (LZT) and a Normative Database
EEG Biofeedback Case Studies Using Live Z Score Training (LZT) and a Normative Database Thomas F. Collura, PhD Joseph Guan, MM.ED, PhD Jeffrey Tarrant, PhD Penijean Rutter, MA Nancy Wigton, MA Fred Starr,
More informationElectroencephalograph EEG-9200J/K
Electroencephalograph EEG-9200J/K Efficient and user-friendly EEG-9200 is a Windows XP desktop PC based electroencephalograph that is efficient and easy to use with 8 ch DSA trendgraph, 3D mapping, high
More informationSleepSign System. FAQs User List Software Overview
FAQs User List Software Overview SleepSign System SSA100W SleepSign System - Frequently Asked Questions 1. Why should I use SleepSign software? 2. Can SleepSign import digital data generated from my BIOPAC
More informationEEG History. Where and why is EEG used? 8/2/2010
EEG History Hans Berger 1873-1941 Edgar Douglas Adrian, an English physician, was one of the first scientists to record a single nerve fiber potential Although Adrian is credited with the discovery of
More informationTo link to this article: PLEASE SCROLL DOWN FOR ARTICLE
Journal of Neurotherapy: Investigations in Neuromodulation, Neurofeedback and Applied Neuroscience Clinical Corner D. Corydon Hammond PhD, Joel F. Lubar PhD & Marvin W. Sams ND Published online: 08 Sep
More informationQuantitative EEG Analyses
Applied Neuroscience, Inc. 8200 Bryan Dairy Rd, Suite #315 Phone: 727-244-0240 Largo, Florida, 33777 Fax: 727-392-1436 www.appliedneuroscience.com email: qeeg@appliedneuroscience.com Quantitative EEG Analyses
More information6/1/2015. Quantitative Electroencephalogram (QEEG) Based Assessment and Treatment in Psychiatry. Assessment in Psychiatry Current Standards
Quantitative Electroencephalogram (QEEG) Based Assessment and Treatment in Psychiatry Teresa Poprawski, MD, QEEGD Chief Medical Officer at Hartgrove Behavioral Health System Clinical Director at First
More informationNeurofeedback for ASD AND ADHD
Neurofeedback for ASD AND ADHD Thomas F. Collura, Ph.D., MSMHC, QEEG-D, BCN, LPC The Brain Enrichment Center and BrainMaster Technologies, Inc., Bedford, OH Association for Applied Psychophysiology and
More informationNeXus: Z-Score for Neurofeedback
NeXus: Z-Score for Neurofeedback This NeXus white paper has been created to educate and inform the reader about the Z-score Neurofeedback functionality offered by the NeXus Instruments with the BioTrace+
More informationIntegrating Quantitative Electroencephalography in Clinical Practice
Integrating Quantitative Electroencephalography in Clinical Practice Gary Schummer, Ph.D. Clinical Director ADD Treatment Center Neurofeedback Center of Los Angeles Torrance, California, USA Western Association
More informationNeurostyle. Medical Innovation for Better Life
Neurostyle Medical Innovation for Better Life Neurostyle Pte Ltd is a company dedicated to design, develop, manufacture and distribute neurological and neuromuscular medical devices. Strategically located
More informationSpeed - Accuracy - Exploration. Pathfinder SL
Speed - Accuracy - Exploration Pathfinder SL 98000 Speed. Accuracy. Exploration. Pathfinder SL represents the evolution of over 40 years of technology, design, algorithm development and experience in the
More informationCONSULTATION / LIAISON PSYCHIATRY
CONSULTATION / LIAISON PSYCHIATRY Dr. Jon Hunter, MD Tel: 416-586-4800 ext. 4557 Fax: 416-586-5970 Email: jhunter@mtsinai.on.ca Jeanette Villapando Tel: 416-586-4800 ext. 8493 Fax: 416-586-8654 Email:
More informationPhotic Output control using BrainMaster Atlantis
Photic Output control using BrainMaster Atlantis Software version 3.5 (and later) December 17, 2009 December 17, 2009 Page 1 of 20 Table of Contents Introduction...3 Autonomous/Immersive Mode...5 PC Controlled
More informationLC/MS/MS SOLUTIONS FOR LIPIDOMICS. Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS
LC/MS/MS SOLUTIONS FOR LIPIDOMICS Biomarker and Omics Solutions FOR DISCOVERY AND TARGETED LIPIDOMICS Lipids play a key role in many biological processes, such as the formation of cell membranes and signaling
More informationNEUROFEEDBACK INNOVATIONS FOR CONCUSSION WITH RETIRED NFL PLAYERS
NEUROFEEDBACK INNOVATIONS FOR CONCUSSION WITH RETIRED NFL PLAYERS 4/1/17 Evaluating the Effectiveness of Ultra Low Power Pulsed Electric Current EEG Biofeedback in Treating Symptoms of Repeated Traumatic
More informationCognitive Enhancement Using 19-Electrode Z-Score Neurofeedback
This article was downloaded by: [Lucas Koberda] On: 22 August 2012, At: 09:31 Publisher: Routledge Informa Ltd Registered in England and Wales Registered Number: 1072954 Registered office: Mortimer House,
More informationLORETA Coherence and Phase Differences
LORETA Coherence and Phase Differences Robert W. Thatcher, Ph.D. 4/25/12 Example from the Neuroguide Demo from a high functioning business professional prior to right hemisphere brain damage by being struck
More informationThe Eclipse High quality evoked potentials at your command. AEP, ASSR, & OAE testing on one dedicated platform
The Eclipse High quality evoked potentials at your command AEP, ASSR, & OAE testing on one dedicated platform Design your own diagnostic solution for a perfect result The Eclipse is a modern and versatile
More informationThe electrophysiological effects of a brain injury on auditory memory functioning The QEEG correlates of impaired memory
Archives of Clinical Neuropsychology 18 (2003) 363 378 Abstract The electrophysiological effects of a brain injury on auditory memory functioning The QEEG correlates of impaired memory Kirtley Thornton
More informationIntegrated Analysis of Copy Number and Gene Expression
Integrated Analysis of Copy Number and Gene Expression Nexus Copy Number provides user-friendly interface and functionalities to integrate copy number analysis with gene expression results for the purpose
More informationThis presentation is the intellectual property of the author. Contact them for permission to reprint and/or distribute.
Modified Combinatorial Nomenclature Montage, Review, and Analysis of High Density EEG Terrence D. Lagerlund, M.D., Ph.D. CP1208045-16 Disclosure Relevant financial relationships None Off-label/investigational
More informationA User s guide to MindReflector Training
A User s guide to MindReflector Training Thomas E. Fink, Ph.D. The brain s electroencephalogram (EEG) reflects the electromagnetic behavior of the brain, which is correlated with many important psychological
More informationSleep Apnea Therapy Software User Manual
Sleep Apnea Therapy Software User Manual Page ii Notices Revised Notice Trademark Copyright 103392 Rev B Published February 8, 2013 and supersedes all previous versions. The information contained in this
More informationGlobal qeeg Changes Associated With Non-frequency & Non-site Specific Neurofeedback Training
Global qeeg Changes Associated With Non-frequency & Non-site Specific Neurofeedback Training Director, Norwalk Hospital Sleep Disorders Center Norwalk CT New York, NY Overview! Describe case study demographics!
More informationSeizure onset can be difficult to asses in scalp EEG. However, some tools can be used to increase the seizure onset activity over the EEG background:
This presentation was given during the Dianalund Summer School on EEG and Epilepsy, July 24, 2012. The main purpose of this introductory talk is to show the possibilities of improved seizure onset analysis
More informationSleepImage Website Instructions for Use
SleepImage Website Instructions for Use Wellness Clinician Account Version 1 MyCardio SleepImage Website Copyright 2017 MyCardio. All rights reserved. Distributed by MyCardio LLC Issued Sept, 2017 Printed
More informationMES 9000 MUSCULOSKELETAL EVALUATION SYSTEM
MES 9000 MUSCULOSKELETAL EVALUATION SYSTEM The new MES 9000. Now you can completely and objectively evaluate and document Dynamic Range of Motion, Static and Dynamic EMG and Muscle Testing All with one
More informationMatrix Energetics Research Brainwaves and Heart waves Research on Matrix Energetics in Action
Matrix Energetics Research Brainwaves and Heart waves Research on Matrix Energetics in Action QEEG (quantitative electroencephalography) and HRV (heart rate variability analysis) tests revealed Dr. Richard
More informationQuantitative EEG Analysis Report. Color coded key for reading the color brain maps and understanding standard deviation:
Quantitative EEG Analysis Report Centers for NeuroTransformation, LLC P.O. Box 129, Lakemont, Ga. 30552 706-212-0195, ifw@mindspring.com www.neurotherapy.us August 8, 2008 Qeeg Functional Brain Interpretation
More informationThought Technology Ltd.
Thought Technology Ltd. 8205 Montreal/ Toronto Blvd. Suite 223, Montreal West, QC H4X 1N1 Canada Tel: (800) 361-3651 ۰ (514) 489-8251 Fax: (514) 489-8255 E-mail: mail@thoughttechnology.com Webpage: http://www.thoughttechnology.com
More informationSupplemental Digital Content 1: Supplemental Results
Supplemental Digital Content 1: Supplemental Results Fig. 1 presents the normalized symbolic transfer entropy (NSTE) matrix of eight electroencephalographic channels and significant changes of connectivity
More informationBioGraph Infiniti DynaMap Suite 3.0 for ProComp Infiniti March 2, SA7990B Ver 3.0
BioGraph Infiniti DynaMap Suite 3.0 for ProComp Infiniti March 2, 2006 SA7990B Ver 3.0 DynaMap Suite 3.0 for ProComp Infiniti Contents List P Inf 8 Ch EMG Bi-Lateral Difference.chs 3 P Inf 8 Ch EMG.chs
More informationSubmitted report on Sufi recordings at AAPB 2013 in Portland. Not for general distribution. Thomas F. Collura, Ph.D. July, 2013
Submitted report on Sufi recordings at AAPB 2013 in Portland Not for general distribution. Thomas F. Collura, Ph.D. July, 2013 Summary of EEG findings The intent of the EEG monitoring was to see which
More informationIII. Comprehensive. Efficient. Auditory EP Testing
V I III Comprehensive. Efficient. Auditory EP Testing Fast, Flexible and User-Friendly Efficient workflow = Focus on the patient The intuitive software and streamlined interpretation with normative data
More informationAC40. The true clinical. hybrid
AC40 The true clinical hybrid The true clinical hybrid audiometer Stand alone & PCbased audiometry in one box A true hybrid audiometer The AC40 full two channel audiometer includes all the advanced features
More informationNeurotherapy and Neurofeedback, as a research field and evidence-based practice in applied neurophysiology, are still unknown to Bulgarian population
[6] MathWorks, MATLAB and Simulink for Technical Computing. Available: http://www.mathworks.com (accessed March 27, 2011) [7] Meyer-Baese U., (2007), Digital Signal Processing with Field Programmable Gate
More informationBioGraph Infiniti DynaMap Suite 3.0 for FlexComp Infiniti March 2, SA7990A Ver 3.0
BioGraph Infiniti DynaMap Suite 3.0 for FlexComp Infiniti March 2, 2006 SA7990A Ver 3.0 DynaMap Suite 3.0 for FlexComp Infiniti Contents List F Inf 10 Ch EMG Bi-Lateral Difference.chs 3 F Inf 10 Ch EMG.chs
More informationSleep Apnea Therapy Software Clinician Manual
Sleep Apnea Therapy Software Clinician Manual Page ii Sleep Apnea Therapy Software Clinician Manual Notices Revised Notice Trademark Copyright Sleep Apnea Therapy Software Clinician Manual 103391 Rev A
More informationEquinox 2.0 PC-based audiometer. Not just an audiometer - A full counseling and reporting solution
Equinox 2.0 PC-based audiometer Not just an audiometer - A full counseling and reporting solution The PC-based Advantage The Equinox 2.0 is a state of the art two channel clinical audiometer. Counseling
More informationNature Neuroscience: doi: /nn Supplementary Figure 1
Supplementary Figure 1 Hippocampal recordings. a. (top) Post-operative MRI (left, depicting a depth electrode implanted along the longitudinal hippocampal axis) and co-registered preoperative MRI (right)
More informationA Brain Computer Interface System For Auto Piloting Wheelchair
A Brain Computer Interface System For Auto Piloting Wheelchair Reshmi G, N. Kumaravel & M. Sasikala Centre for Medical Electronics, Dept. of Electronics and Communication Engineering, College of Engineering,
More informationA Study of Smartphone Game Users through EEG Signal Feature Analysis
, pp. 409-418 http://dx.doi.org/10.14257/ijmue.2014.9.11.39 A Study of Smartphone Game Users through EEG Signal Feature Analysis Jung-Yoon Kim Graduate School of Advanced Imaging Science, Multimedia &
More informationNovel single trial movement classification based on temporal dynamics of EEG
Novel single trial movement classification based on temporal dynamics of EEG Conference or Workshop Item Accepted Version Wairagkar, M., Daly, I., Hayashi, Y. and Nasuto, S. (2014) Novel single trial movement
More informationNeuro-MEP-Micro EMG EP. 2-Channel Portable EMG and NCS System with a Built-in Miniature Dedicated Keyboard. EMG according to international standards
Neuro-MEP-Micro 2-Channel Portable EMG and NCS System with a Built-in Miniature Dedicated Keyboard EMG according to international standards Instant analysis of high-quality responses Over 50 EMG and EP
More informationSeparation Of,, & Activities In EEG To Measure The Depth Of Sleep And Mental Status
Separation Of,, & Activities In EEG To Measure The Depth Of Sleep And Mental Status Shah Aqueel Ahmed 1, Syed Abdul Sattar 2, D. Elizabath Rani 3 1. Royal Institute Of Technology And Science, R. R. Dist.,
More informationEBCC Data Analysis Tool (EBCC DAT) Introduction
Instructor: Paul Wolfgang Faculty sponsor: Yuan Shi, Ph.D. Andrey Mavrichev CIS 4339 Project in Computer Science May 7, 2009 Research work was completed in collaboration with Michael Tobia, Kevin L. Brown,
More informationISSN: (Online) Volume 3, Issue 7, July 2015 International Journal of Advance Research in Computer Science and Management Studies
ISSN: 2321-7782 (Online) Volume 3, Issue 7, July 2015 International Journal of Advance Research in Computer Science and Management Studies Research Article / Survey Paper / Case Study Available online
More informationMentis Cura November
Mentis Cura November 29 2012 www.mentiscura.com New Facts on Alzheimer s Death rank nr. 2-5 in western countries Fastest growing disease in: Cost Incedence Death rate People with Alzheimer s 2012 36 million
More informationUse of Databases in QEEG Evaluation
Use of Databases in QEEG Evaluation Jack Johnstone, PhD Jay Gunkelman, QEEG-D About the Authors: Jack Johnstone is President and CEO of Q-Metrx, Inc., Burbank, California. Jay Gunkelman is Executive Vice
More informationThe objective of this article is to present and investigate the idea of multi-modality
Multi-Modality Intensive Neurofeedback Jamie Moore, RN, BCN and Erica Kube, BS Abstract The objective of this article is to present and investigate the idea of multi-modality intensive neurofeedback (infb).
More informationFREQUENTLY ASKED QUESTIONS Updated v1.0
FREQUENTLY ASKED QUESTIONS Updated 08.12.08 v1.0 VeriPRO Helpdesk 877.VERIPRO [877.837.4776] For questions or additional VeriPRO support, please contact our Technical Helpdesk, available between 7.00 am
More informationQEEG Informed Protocol Recommendation
Protocol ecommendation Psychopathology ating Substance Use AD(H)D (page 2) Depression (page 3) Anxiety Disorder OCD Autism Schizophrenia Memory Disorder Insomnia Stimulants Anti depressants Anxiolytics/Sedatives
More informationCopyright: Thornton. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (CC-BY).
A QEEG Activation Methodology That Obtained % Accuracy in the Discrimination of Traumatic Brain Injured from and Does the Learning Disabled Show the Brain Injury Pattern? Kirtley E. Thornton* The Neuroscience
More informationBCIA NEUROFEEDBACK CERTIFICATION PROGRAM 2019
BCIA NEUROFEEDBACK CERTIFICATION PROGRAM 2019 Instructor: Cynthia Kerson, PhD (36 BCIA F2F Hours) Level: Introductory to Intermediate Instructor: Cynthia Kerson, 2(PhD), QEEGD, BCN, BCB, BCB-HRV Hong Kong
More informationThe Eclipse Designed to meet your every need. AEP, ASSR, VEMP & OAE testing on one dedicated platform
The Eclipse Designed to meet your every need AEP, ASSR, VEMP & OAE testing on one dedicated platform Design your own diagnostic solution for a perfect result The Eclipse is a modern and versatile platform.
More informationThe Epilog Chapters. Chapter 36, 37, 38 John JB Allen
The Epilog Chapters Chapter 36, 37, 38 John JB Allen Recommendations in Reporting Results Chapter 36 The modal viewer: Title Abstract Figures Recommendations in Reporting Results #1: One figure, one idea
More informationPathfinder Holter Analyzer CARDIAC DIAGNOSTIC SOLUTIONS
Pathfinder Holter Analyzer CARDIAC DIAGNOSTIC SOLUTIONS Pathfinder Digital - An Evolution... Del Mar Reynolds rich history of innovation began nearly a half century ago with the development of Holter monitoring
More informationRestoring Communication and Mobility
Restoring Communication and Mobility What are they? Artificial devices connected to the body that substitute, restore or supplement a sensory, cognitive, or motive function of the nervous system that has
More informationBrainMaster Knowledge Base Article Using the Swingle Clinical Q Assessment and Spreadsheet by Gary Ames July 31, 2011
BrainMaster Knowledge Base Article Using the Swingle Clinical Q Assessment and Spreadsheet by Gary Ames July 31, 2011 1. Clinical Q vs. QEEG 2. Mindset for the Clinical Q 3. Running the Clinical Q Assessment
More informationIn-vivo EEG Changes During A Panic Attack in A Patient With Specific Phobia
Elmer Press Case Report In-vivo EEG Changes During A Panic Attack in A Patient With Specific Phobia Hessel J. Engelbregt a, d, Daniel Keeser b, Vincent H.L. Promes a, Sonja Verhagen-Schouten a, Jan Berend
More informationABSTRACT 1. INTRODUCTION 2. ARTIFACT REJECTION ON RAW DATA
AUTOMATIC ARTIFACT REJECTION FOR EEG DATA USING HIGH-ORDER STATISTICS AND INDEPENDENT COMPONENT ANALYSIS A. Delorme, S. Makeig, T. Sejnowski CNL, Salk Institute 11 N. Torrey Pines Road La Jolla, CA 917,
More informationBiopac Student Lab Lesson 3 ELECTROENCEPHALOGRAPHY (EEG) I Analysis Procedure. Rev
42 Aero Camino, Goleta, CA 93117 www.biopac.com Biopac Student Lab Lesson 3 ELECTROENCEPHALOGRAPHY (EEG) I Analysis Procedure Rev. 12112014 Richard Pflanzer, Ph.D. Associate Professor Emeritus Indiana
More informationBeltone Solus Pro 1.9 Fitting Guide
Beltone Solus Pro 1.9 Fitting Guide Table of Contents Table of Contents... 2 Getting started... 3 Start Screen... 3 Assigning Devices... 4 Connection Process... 5 MSG Calibration... 5 Gain Adjustment...
More informationWalkthrough
0 8. Walkthrough Simulate Product. Product selection: Same look as estore. Filter Options: Technology levels listed by descriptor words. Simulate: Once product is selected, shows info and feature set Order
More informationEmotion Detection Using Physiological Signals. M.A.Sc. Thesis Proposal Haiyan Xu Supervisor: Prof. K.N. Plataniotis
Emotion Detection Using Physiological Signals M.A.Sc. Thesis Proposal Haiyan Xu Supervisor: Prof. K.N. Plataniotis May 10 th, 2011 Outline Emotion Detection Overview EEG for Emotion Detection Previous
More informationTitan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device.
Titan power The best just got better Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device. Let your equipment and needs interact The Titan from Interacoustics is a modular
More informationEEG Analysis on Brain.fm (Focus)
EEG Analysis on Brain.fm (Focus) Introduction 17 subjects were tested to measure effects of a Brain.fm focus session on cognition. With 4 additional subjects, we recorded EEG data during baseline and while
More informationDEMOGRAPHICS IMPACT FACTOR / SPECIALTY FIELD
2018 MEDIA KIT EPILEPSY CURRENTS Volume 17 Issue 4 Current Status of Treatments for Children with Electrical Status in SlowWave Sleep (ESES/CSWS)... How Closely Should We Monitor for Nocturnal Seizures?...
More informationTitan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device
Titan power The best just got better Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device Let your equipment and needs interact The first and only one of its kind 4
More informationAT235/AT235h Middle Ear Analyzers. Diagnostic & clinical tympanometry with basic audiometry.
AT235/AT235h Middle Ear Analyzers Diagnostic & clinical tympanometry with basic audiometry. Fast & reliable middle ear analyzer The AT235 is an automatic middle ear analyzer ideal for diagnostic and screening
More informationThe Effectiveness of EEG Biofeedback and Cognitive Rehabilitation as Treatments for Moderate to Severe Traumatic Brain Injury
The Effectiveness of EEG Biofeedback and Cognitive Rehabilitation as Treatments for Moderate to Severe Traumatic Brain Injury Joanne Stephens A research thesis submitted in partial fulfilment of the requirements
More informationTallahassee NeuroBalance Center, Tallahassee, Florida, USA Published online: 21 Aug 2012.
Journal of Neurotherapy: Investigations in Neuromodulation, Neurofeedback and Applied Neuroscience Application of Neurofeedback in General Neurology Practice J. Lucas Koberda a, Donna S. Hillier a, Barry
More informationFeatures and Benefits
Features and Benefits DC7 Significant Features HIPAA Compliant Frequency Compound Imaging Standard i-clear Standard i-beam Standard SCI Digital Processing Channels 2048 Dynamic Range > 160 Db 10 Bit A/D
More informationThe Most Outstanding Features & Benefits of Today s Auditory Evoked Potentials (AEP) Systems
Authored by: Whenever faced with purchasing new equipment, the makes and models on the market can be confusing. It helps to know some basics, what comparable products are on the market, and what each of
More informationTesting the Accuracy of ECG Captured by Cronovo through Comparison of ECG Recording to a Standard 12-Lead ECG Recording Device
Testing the Accuracy of ECG Captured by through Comparison of ECG Recording to a Standard 12-Lead ECG Recording Device Data Analysis a) R-wave Comparison: The mean and standard deviation of R-wave amplitudes
More informationCorrelation Dimension versus Fractal Exponent During Sleep Onset
Correlation Dimension versus Fractal Exponent During Sleep Onset K. Šušmáková Institute of Measurement Science, Slovak Academy of Sciences Dúbravská cesta 9, 84 19 Bratislava, Slovak Republic E-mail: umersusm@savba.sk
More informationTitan power The best just got better. Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device
Titan power The best just got better Impedance, OAE, ABRIS and the revolutionary Wideband Tympanometry in one powerful device Let your equipment and needs interact The Titan from Interacoustics is a modular
More informationCorporate Medical Policy
Corporate Medical Policy Quantitative Electroencephalography as a Diagnostic Aid for Attention File Name: Origination: Last CAP Review: Next CAP Review: Last Review: quantitative_electroencephalography_as_a_diagnostic_aid_for_adhd
More informationNeuroSky s esense Meters and Detection of Mental State
NeuroSky s esense Meters and Detection of Mental State The Attention and Meditation esense meters output by NeuroSky s MindSet are comprised of a complex combination of artifact rejection and data classification
More informationSedLine Sedation Monitor
SedLine Sedation Monitor Quick Reference Guide Not intended to replace the Operator s Manual. See the SedLine Sedation Monitor Operator s Manual for complete instructions, including warnings, indications
More informationNature Neuroscience: doi: /nn Supplementary Figure 1. Large-scale calcium imaging in vivo.
Supplementary Figure 1 Large-scale calcium imaging in vivo. (a) Schematic illustration of the in vivo camera imaging set-up for large-scale calcium imaging. (b) High-magnification two-photon image from