1 NURSING PRACTICE & SKILL Authors Tanja Schub, BS Mary Woten, RN, BSN Reviewers Eliza Schub, RN, BSN Teresa-Lynn Spears, RN, MSN Nursing Practice Council Glendale Adventist Medical Center, Glendale, CA Editor Diane Pravikoff, RN, PhD, FAAN Intra-aortic Balloon Pump: Overview of Patient Management What is Involved in Management of a Patient with an Intra- Aortic Balloon Pump? The intra-aortic balloon pump (IABP) employs a balloon-tipped catheter and a process called counterpulsation to temporarily support coronary and systemic perfusion in patients with severe cardiac disease (e.g., cardiogenic shock) or injury (e.g., myocardial infarction [MI]). The catheter is typically inserted into the femoral artery, threaded close to the descending aortic arch, and attached to an external pump which inflates and deflates the intra-aortic balloon (IAB) in synchrony (timed) with the cardiac cycle. IABP therapy provides temporary hemodynamic support by increasing coronary and systemic perfusion until the heart can resume its function/workload or until cardiac transplantation is performed. The information contained in this Nursing Practice & Skill lesson is intended to present a brief overview of caring for the patient receiving IABP therapy and is not intended to replace facility/unit-specific protocols, clinician orders, or the comprehensive coursework and clinical experience necessary to become proficient in caring for the patient IABP (for information about IAB insertion, timing, pressure wave assessment, weaning, and removal, see the related series of Nursing Practice & Skill papers) What: Management of a patient receiving IABP therapy requires managing the computerized IABP console; assessing, monitoring, and adjusting balloon inflation and deflation (referred to as timing); monitoring patient response to IABP therapy; and performing intervention to prevent complications that can arise as a result of the presence of the IAB catheter (for details, see What You Need to Know Before Managing a Patient with an Intra-aortic Balloon Pump, below) How: In accordance with treating clinician orders and facility protocols, the nurse caring for a patient receiving IABP therapy evaluates the proper functioning of the IABP and balloon inflation/deflation - NOTE: In many facilities, an IABP technician or perfusionist is responsible for monitoring the mechanical components of the IABP the accuracy of balloon timing for signs of vascular compromise (for details, see Red Flags, below) or other complications of IAB catheter placement (e.g., bleeding at the insertion site) the patient s response to IABP therapy Where: Management of a patient receiving IABP therapy is performed in the operating room or cardiac catheterization suite where the IAB catheter was placed, and in the ICU after placement Who: Management of a patient receiving IABP therapy is performed by a specially trained critical care nurse; an IABP technician or perfusionist is typically responsible for monitoring the mechanical components of the IABP. Care of the patient with an IABP cannot be delegated to assistive personnel. In the interest of minimizing contaminants, family members are not usually permitted to be present during insertion site dressing changes, although they may be present during routine assessment and management December 28, 2018 Published by Cinahl Information Systems, a division of EBSCO Information Services. Copyright 2018, Cinahl Information Systems. All rights reserved. No part of this may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, or by any information storage and retrieval system, without permission in writing from the publisher. Cinahl Information Systems accepts no liability for advice or information given herein or errors/omissions in the text. It is merely intended as a general informational overview of the subject for the healthcare professional. Cinahl Information Systems, 1509 Wilson Terrace, Glendale, CA 91206

2 What is the Desired Outcome of Managing the Patient with an Intra-Aortic Balloon Pump? The patient receiving IABP therapy will experience optimal counterpulsation and hemodynamic support with no complications as a result of IAB catheter placement or IABP therapy. Expected outcomes of IABP therapy include (de Jong et al., 2017) increased coronary artery perfusion decreased left ventricular(lv) workload decreased myocardial oxygen consumption decreased afterload increased renal blood flow increased splanchnic blood flow Why is Management of the Patient with an Intra-Aortic Balloon Pump Important? Because IABP therapy is a highly invasive strategy associated with severe and potentially life-threatening complications (e.g., hemorrhage), intensive management of patients with an IABP is important to ensure optimal counterpulsation and patient outcomes and to prevent complications. Facts and Figures Investigators who conducted a meta-analysis of 10 international randomized trials reported that use of IABP was not associated with reduced 30-daymortality rates in patients undergoing high-risk reperfusion therapy, but was associated with a 37% reduction in 6-month mortality rates (Chen et al., 2014) Authors of a study examining U.S. trends in IABP usage in light of the conflicting evidence of its usefulness found that it is being used much less than before due to better treatment of acute coronary syndrome, including early revascularization and better prevention (Patel et al., 2014) Researchers conducting a retrospective chart review to evaluate the effect of IABP therapy on activity tolerance of 45 adult patients awaiting heart transplantation concluded that IABP therapy can allow safely increased physical mobilization among patients awaiting heart transplants, promoting improved preoperative strengthening, decreasing need for assistance with postoperative activity, and significantly shortening length of hospital stay (Green et al., 2015) Researchers in a meta-analysis determined that the use of IABP therapy before coronary artery bypass grafting (CABG) was associated with decreased mortality, a shorter ICU length of stay (LOS), and a shorter overall LOS (Poirier et al., 2016) Researchers in a systematic review of 20 studies reported an incidence of vascular complications of %. Limb ischemia, bleeding, and mesenteric ischemia were the most common vascular complications. Factors that increased risk for IABP complications were diabetes, smoking, peripheral vascular disease, and hypertension (de Jong et al., 2017) Roughly 7% of patients utilize IABP therapy following cardiac surgery (Parissis et al., 2016) Factors that can preclude the use of IABP therapy in children include small stroke volume, small aortic size, and high aortic elasticity(parissi s et al., 2016) What You Need to Know Before Managing a Patient with an Intra-Aortic Balloon Pump Managing a patient with an IABP requires specialized training and a strong foundation in critical care skills, including knowledge of and demonstrated competence in the following critical care/nursing skills: anatomy and physiology of the cardiovascular system, including the events of the normal cardiac cycle EKG monitoring (for more information, see the series of Nursing Practice & Skills papers on EKG monitoring) arterial pressure monitoring (for more information, see Nursing Practice & Skill Arterial Catheter, Indwelling: Monitoring Arterial Pressure ) The IABP can rely on a traditional arterial line set-up and fluid-filled transducer system to monitor arterial pressure in the aorta, or the IAB catheter can be a fiberoptic catheter with a sensor at the tip for monitoring and transmitting the arterial pressure waveform. If a fluid-filled transducer is to be used, the nurse must know how to set up and manage a pressure transducer system (for more information, see Nursing Practice & Skill Pressure Transducer System, Intravascular/ Intracardiac: Setting Up ) how to analyze an arterial pressure waveform pulmonary artery pressure monitoring (for more information, see Nursing Practice & Skill Pulmonary Artery Catheter: Monitoring Pulmonary Artery Pressure )

3 how to measure cardiac output (for more information, see the related series of Nursing Practice & Skill papers on measuring cardiac output) cardiovascular assessment (for more information, see Nursing Practice & Skill Physical Assessment: Performing a Cardiovascular Assessment in Adults ) advanced cardiac life support (ACLS) protocols infection control procedures and aseptic technique (for more information, see the series of related Nursing Practice & Skill papers) Knowledge of how the IABP functions and provides hemodynamic support is essential IABP therapy involves use of a double-lumen catheter with a 25 50cm 3 balloon that lies about 2 cm inferior to the left subclavian artery and proximal to the renal arteries. The balloon inflates and deflates in synchrony with the patient s cardiac cycle; the outer lumen of the catheter allows for movement of helium to and from the IAB, while the inner lumen is typically used for arterial pressure monitoring. The balloon should not occlude > 85-90% of the aorta when inflated Balloon inflation is set to start at the beginning of ventricular diastole, which corresponds to the middle of the T-wave on the EKG or at or just prior to the dicrotic notch (i.e., aortic valve closure) on the arterial pressure waveform. Balloon deflation is set to occur just prior to the onset of ventricular systole, which corresponds to the peak of the R-wave on the EKG or prior to the arterial upstroke on the arterial pressure waveform (for more information, see Nursing Practice & Skill Intra-aortic Balloon Pump: Timing of ). Inflation during diastole increases retrograde perfusion to the coronary arteries. Deflation at the onset of systole (during the pre-ejection phase) decreases afterload, end-diastolic pressure, the workload of the LV, and myocardial oxygen consumption, and increases cardiac output; this action is referred to ascounterpulsation Initially, when the patient requires the most support, the IABP can be set to augment each beat (1:1 assist ratio), also known as maximum augmentation. As the patient requires less support, the ratio can be adjusted to a minimum of 1:8 to wean the patient from IABP therapy, after which IABP support can usually be discontinued Timing errors can result in significant and life-threatening adverse effects. Early inflation is the most dangerous timing error because inflation occurs during systole which results in a significant increase in LV workload as it pumps against the pressure of the inflated balloon Incorrect IABP timing can cause - decreased cardiac output (early inflation, early deflation, late deflation) - hypotension (early inflation, early deflation, late deflation) - increased myocardial oxygen demand and consumption (early inflation, late deflation) - myocardial ischemia (late inflation, perhaps early deflation) Indications for IABP therapy include LV failure, especially those patients with an ejection fraction < 35% and patients who are awaiting heart transplantation unstable angina cardiogenic shock following myocardial infarction (MI) high-risk percutaneous transluminal cutaneous angioplasty (PTCA) status or failed PTCA the need for hemodynamic support prior to, during, and/or after cardiac surgery inability to be weaned from cardiopulmonary bypass support following cardiac surgery refractory ventricular arrhythmias septic shock Knowledge of how to assess the IABP augmented arterial pressure waveform and the balloon pressure waveform is essential to ensure optimal counterpulsation The accuracy of IABP timing is assessed by evaluating the changes in the arterial pressure waveform caused by the IABP when the augmentation ratio is set at 1:2 or 1:3 (for details, see Nursing Practice & Skill Intra-aortic Balloon Pump: Timing of; CINAHL Topic ID Number T706035). Incorrect timing can result in decreased cardiac output, diminished blood pressure, increased myocardial oxygen demand and consumption, and myocardial ischemia. The augmented arterial pressure waveform should demonstrate a rapid upstroke at the dicrotic notch (indicating a rapid rise in aortic pressure) that results in an augmented peak diastolic pressure that is greater than the patient s systolic pressure a balloon aortic end-diastolic pressure that is lower than the native patient end-diastolic pressure; the balloon aortic end-diastolic pressure should appear as a distinct V the slopes of the assisted and unassisted systolic pressure waveforms are equal an assisted peak systolic pressure lower than the unassisted peak systolic pressure

4 The balloon pressure waveform must be assessed to verify that the inflation/deflation process is occurring correctly, that the catheter is not kinked or leaking, and that optimal counterpulsation is occurring (for details, see Nursing Practice & Skill Intra-aortic Balloon Pump: Assessing the Pressure Waveform ). Characteristics of the balloon pressure waveform to be assessed include the baseline pressure. Normal fill pressure is typically mmhg a rapid upstroke as the balloon is inflated with helium. A normal upstroke will be sharp and vertical or nearly vertical an inflation artifact as the maximum pressure in the balloon is reached a plateau pressure, which represents duration of inflation. The presence of a plateau indicates the duration of inflation during diastole and confirms that the balloon is fully inflated The height of the plateau indicates the pressure in the aorta while the IAB is inflated and should be within mmhg of the augmented peak diastolic pressure a rapid downstroke as the balloon deflates. A normal downstroke will be sharp and nearly vertical a negative deflation artifact below the baseline that occurs as helium returns to the helium supply pump and then stabilizes - The deflation artifact may be missing in hypertensive patients a return to baseline Knowledge of how the IABP console functions and how to respond to alarms is important The IABP console displays the EKG tracing, arterial pressure waveform, and the Balloon pressure waveform, as well as numerical readings of heart rate and arterial pressure The IABP console can alarm for a variety of reasons (e.g., occlusion of the IAB, loss of the trigger). Alarms must be responded to promptly as the system may cease counterpulsation when in an alarm state The pneumatic system that inflates/deflates the balloon must be assessed periodically, the helium tank pressure monitored, and the helium tank changed as needed; these responsibilities typically fall to the perfusionist For details, see the manufacturer s instructions for the specific IABP system in use, as well as the series of Nursing Practice & Skills papers regarding IABP management and timing Knowledge of potential complications of IABP therapy. Limb ischemia is the most common vascular complication of IABP therapy (see Red Flags, below). Other complications include compartment syndrome (i.e., excessive pressure in muscles that prevents adequate oxygenation and can lead to paralysis, loss of limb, or death) vascular injury, including aortic laceration or dissection, dislodging of plaque, and arterial perforation left arm ischemia (evidenced by pain and impaired circulation in the left arm) if the balloon is displaced proximally and occludes the left subclavian artery hemorrhage due to anticoagulation Heparin-induced thrombocytopenia can occur. In addition, damage to platelets can occur as a result of the balloon inflation and deflation. Patients with a lower initial platelet count are at a substantially higher risk for thrombocytopenia than patients with an initial platelet count that is within normal parameters gas embolus secondary to balloon rupture If balloon rupture is suspected, the IAB catheter must be removed immediately to reduce risk for air embolus (see Red Flags, below) balloon entrapment (i.e., an inability to remove the IAB catheter, which can result in the need for surgical removal) thromboembolism thrombocytopenia Heparin-induced thrombocytopenia can occur. In addition, damage to platelets can occur as a result of the balloon inflation and deflation. Patients with a lower initial platelet count are at a substantially higher risk for thrombocytopenia than patients with an initial platelet count that is within normal parameters cardiac tamponade peripheral nerve damage if a cutdown was used to insert the catheter impaired cerebral circulation (evidenced by neurologic changes including agitation or changes in level of consciousness) if the balloon is displaced proximally and occludes the subclavian artery renal ischemia (evidenced by a decrease in urinary output) if the balloon is displaced distally and occludes the renal arteries infection and/or sepsis Strict adherence to aseptic technique is necessary. Patient visitors should be instructed in hand hygiene Preliminary steps that should be performed before managing a patient with an IABP include the following: Review the facility/unit protocol for IABP therapy, if one is available

5 Review the treating clinician s orders for IABP therapy, monitoring parameters, laboratory tests, and/or related medication Verify completion of facility informed consent documents Review the patient s medical history/medical record for indications for IABP therapy patient s response to IABP therapy medications ordered previous waveform tracings any allergies (e.g., to latex, medications, or other substances); use alternative materials, as appropriate Review the manufacturer s instructions for all equipment to be used and verify that the equipment is in good working order The IABP should already be in use at the patient s bedside. Gather the necessary supplies, which typically include Nonsterile gloves; additional personal protective equipment (PPE; e.g., gown, mask, eye protection) may be needed if exposure to body fluids is anticipated Equipment for monitoring vital signs Facility-approved pain assessment tool Doppler for assessing pedal and/or tibial pulses, if needed Prescribed sedative and analgesia and means for administering 60-cc syringe to manually inflate the balloon in the event of pump malfunction Emergency resuscitation equipment (e.g., defibrillator, suction equipment, and medications for advanced cardiac life support [ACLS] protocols) should be readily available Written materials to reinforce patient education Contact the IABP technician or perfusionist, if available, to assist with the IABP console if difficulties arise How to Manage a Patient with an Intra-Aortic Balloon Pump Perform hand hygiene and don PPE as appropriate Identify the patient using two unique identifiers, according to facility protocol Establish privacy by closing the door to the patient s room and/or drawing the curtain surrounding the patient s bed Introduce yourself to the patient and family member(s), if present; explain your clinical role; assess the coping ability of the patient and family and for knowledge deficits and anxiety regarding IABP therapy Determine if the patient/family requires special considerations regarding communication (e.g., due to illiteracy, language barriers, hearing impairment); make arrangements to meet these needs if they are present Use professional certified medical interpreters, either in person or via phone, when language barriers exist Reinforce the purpose of IABP therapy and the need to keep the affected extremity immobile; answer any questions and provide emotional support as needed Verify that the patient is supine with the head of the bead 30 and with the affected limb immobilized (6) Perform a thorough assessment of the patient s cardiovascular system and hemodynamic status to determine response to IABP therapy as currently timed Assess vital signs and level of pain using a facility-approved pain assessment tool. Administer analgesics and sedatives, as ordered Zero the transducer, according to manufacturer s instructions, to ensure accuracy of the readings (6) If using an IABP that requires a fluid-filled transducer, verify that the transducer set up is intact flush the arterial line to assess patency level the transducer with the patients phlebostatic axis Assess and adjust the timing of balloon inflation and deflation every hour, if there is a change in heart rate > 10 bpm, and if there is a change in the patient s heart rhythm (6) Select an EKG lead on the IABP console that produces the largest R-wave to allow for optimal triggering Set the console to manual or operator mode if on an automatic timing setting Set the assist ratio to 1:2 (50% augmentation) (6) Run an arterial pressure waveform strip to use to assess the timing of balloon inflation and deflation Identify the dicrotic notch of the augmented waveform. Draw a line that passes through the dicrotic notches of several systolic waveforms recorded on the strip (6)

6 Change the inflation point briefly to occur after the dicrotic notch so that the dicrotic notch can be identified instantly, then immediately change to occur at or just prior to the dicrotic notch (6) Adjust the inflation point as needed so that it produces a sharp and deep V at the dicrotic notch The appearance of a deep, sharp V wave serves to confirm that inflation is correctly occurring at the onset of diastole Confirm that the augmented peak diastolic pressure is greater than the patient s unassisted systolic pressure Identify and compare the augmented end-diastolic pressure and the patient s unassisted end-diastolic pressures (6) The augmented end-diastolic pressure should appear as a sharp and deep V and be lower than the patient s unassisted end-diastolic pressure Verify that the assisted peak systolic pressure is lower than the patient s native peak systolic pressure (6) Slightly adjust deflation earlier or later as needed so that (6) the augmented end-diastolic pressure is lower than the patient end-diastolic pressure and forms a distinct sharp and deep V the assisted systolic pressure is less than the unassisted systolic pressure Set the IABP back to 1:1 augmentation, or as ordered (6) Assess the characteristics of the balloon pressure waveform Run a strip of the balloon pressure waveform Verify that the baseline uninflated pressure in the balloon is 0 2.5mmHg (6) Verify that the upstroke of the waveform is sharp and vertical or nearly vertical (6) Assess for the presence of a peak inflation artifact followed by a rapid drop-off (6) Assess for the presence of a pressure plateau (6) Verify that the downstroke immediately following the pressure plateau is sharp and nearly vertical (6) Assess for a negative deflection below the baseline (6) Assess the width of the waveform, starting at the beginning of the inflation upstroke and ending when the deflation downstroke crosses the baseline. Verify that it matches the width of the augmented arterial waveform (6) Troubleshoot the IABP, if necessary, according to manufacturer instructions or facility protocol, if the normal characteristics of the balloon pressure waveform are not present (6) If the balloon is inflating early or late, adjust the inflation point so that the balloon inflates at or just before the dicrotic notch (6) Be aware that early inflation is the most dangerous timing error If the balloon is deflating early or late, adjust the deflation point so that there is a sharp diastolic wave and the greatest increase in the augmented systolic pressure (6) If the fill pressure is elevated > 2.5 mmhg assess the catheter or connecting tubing for kinks and straighten, as needed assess for improper balloon positioning; perform a patient assessment (e.g., assess urine output and pulses) and request X-ray to verify placement, as needed If the plateau pressure is lower than expected (e.g., > 25 mmhg lower than the augmented peak diastolic pressure), assess the helium supply for leaks or a low supply that could cause a decreased plateau pressure; secure all connections and change the helium tank, as needed Call the IABP technician or perfusionist may need to be called if there are concerns about the helium supply and balloon inflation, according to facility protocol If the plateau pressure is higher than expected (e.g., > 25 mmhg higher than the augmented peak diastolic pressure) assess the catheter or connecting tubing for kinks and straighten, as needed decrease the volume of helium used for inflation, according to the treating clinician s order or facility/unit protocol if it is suspected that the balloon is too large for the aorta If the waveform is narrow but the patient s heart rate is not rapid, assess the timing for late inflation or early deflation If the waveform rhythm is erratic but the patient has a regular rhythm, assess the IABP trigger to verify that the trigger is appropriate and is being sensed; adjust the trigger, as indicated Routinely check for the presence of blood in the connecting tubing, which is a hallmark of balloon rupture and is considered a medical emergency (for details, see Red Flags, below)

7 If balloon rupture is suspected (e.g., blood in the helium tubing), immediately (6) place the console on standby to prevent pumping helium into the patient clamp the IAB catheter to prevent blood back-flow into the catheter remove the IAB catheter from the console to prevent blood from entering the console notify the treating clinician prepare for immediate removal/replacement of the IAB catheter discontinue anticoagulant therapy if ordered Perform a physical assessment of the patient every minutes, according to facility protocol Assess for hypotension and/or pain in the abdomen, flank or back, which can indicate retroperitoneal bleeding Assess for a blood pressure differential between the left and right sides of the body, pallor, dyspnea,syncope, diaphoresis, and pain in the chest, abdomen, or back as these can indicate dissecting aortic aneurysm Assess cardiac rate and rhythm; auscultate heart sounds and assess cardiac output, according to facility protocol If the patient is hemodynamically stable, the IABP can be placed on standby briefly so that heart sounds can be more easily auscultated Assess respiratory status, including ventilator settings, if applicable, and pulse oximetry. Assess pedal and tibial pulses distal to the IAB catheter insertion site; assess for changes in capillary refill, color, temperature, and sensation of the affected limb. Use a Doppler to assess pulses, as needed Assess the radial and ulnar pulses and for changes in capillary refill, color, temperature, and sensation in the left arm Assess the patient s urinary output A decrease in urinary output can indicate that the balloon is displaced downward and is occluding the renal arteries Assess for neurologic changes, although this may not always be possible because many patients are sedated during IABP therapy Changes in level of consciousness can indicate reduced cerebral blood flow. If the patient is agitated, the risk for catheter displacement is greater Administer sedative, if ordered, to reduce agitation, if present, and reduce risk for catheter displacement Auscultate bowel sounds and palpate the abdomen for distention or tenderness, which can indicate thrombus, internal bleeding, or mesenteric ischemia Inspect the IAB catheter insertion site Verify that the catheter is secured to the patient s skin, either with sutures or a catheter securement device (6) Assess for signs of infection (e.g., redness, drainage) Change the dressing at the insertion site every 24 hours or according to facility protocol using strict aseptic technique. A transparent occlusive dressing can be used as this allows for better visualization of the insertion site Assess for bleeding at the insertion site or from other sites (e.g., blood in urine or stools, bleeding gums, petechiae) that suggest over anticoagulation Assess the skin of the lower limb, especially the heel, for redness or pain, which could indicate pressure injury formation Monitor laboratory test results, including PT/PTT to assess bleeding risk serum electrolytes (e.g., potassium) as abnormalities can increase risk for arrhythmia serum creatinine levels to assess risk of compromised renal perfusion Verify proper mechanical functioning of the IABP Monitor for pump interruption, which may be the result of improper body alignment, loose EKG electrodes or lead wires, outside electrical interference, or kinks in the catheter Confirm that the back-up battery for the IABP console is fully charged in case of power failure or if it becomes necessary to transport the patient Obtain a new IABP console in the event of pump malfunction; perform manual pumping if a new console not immediately available Use the 60-cc syringe to manually pump the balloon with room air a minimum of once every five minutes to prevent thrombus formation in the catheter. When inflating the balloon manually with room air, the volume of inflation is 10 ml less than the balloon volume marked on the catheter Discard used supplies appropriately and perform hand hygiene Update the patient s medication administration record (MAR) and plan of care, if appropriate, and document the following information in the patient s medical record and on the IABP flowsheet: Date and time of assessments and care provided

8 Details of timing, pressure waveform, and pump assessment Patient assessment findings, including vital signs level of pain hemodynamic measurements results of cardiovascular, respiratory, neurologic,abdominal,and skin assessment presence and strength of peripheral pulses I & O insertion site and any indications of bleeding or infection Details of patient positioning Complications or mechanical malfunctions that occurred, interventions performed, whether or not the treating clinician was notified, and patient outcome All patient and family education provided, including topics presented, response to education, plan for follow-up education, barriers to communication, and techniques that promoted successful communication and emotional support Other Tests, Treatments, or Procedures That May be Necessary Before or After Managing a Patient with an IABP Chest X-rays may be ordered daily to verify correct placement of the IABP ABGs are routinely ordered to evaluate the effectiveness of the IABP and the patient s oxygenation and respiration status The patient s hematologic status is closely monitored, especially for infection and bleeding. Laboratory tests include CBC with differential and platelets. The platelet count is assessed for the increased risk of thrombocytopenia Hct and Hgb values to monitor for hemorrhage PTT levels if the patient is receiving heparin therapy in order to monitor that a level times the normal value is maintained What to Expect After Management of a Patient with an Intra-Aortic Balloon Pump The patient s cardiac workload will be reduced and myocardial perfusion will be increased The patient s cardiac function will improve The patient will not experience adverse effects from the IABP therapy Red Flags Limb ischemia is the most common vascular complication. Patients with a history of peripheral vascular disease are particularly at risk. Routinely palpate pedal and posterior tibial pulses, noting both presence and strength; if pulses are not palpable, a Doppler must be used to monitor neurovascular status and prevent limb ischemia. Pain or changes in the color, sensation, capillary refill, and temperature of the affected limb can also indicate limb ischemia and/or compartment syndrome. Provide ongoing documentation, and report changes to the clinician. If the patient develops ischemia, the IAB catheter will have to be removed Ischemia of the left arm can also occur if the balloon is displaced proximally and occludes the left subclavian artery. Loss of pulses,pain, or changes in the color, sensation, and temperature in the left arm may indicate upward balloon displacement. Renal ischemia can occur if the balloon is displaced distally and occludes the renal arteries. Although less common than limb ischemia, visceral and mesenteric ischemia can occur due to incorrect balloon positioning which compromises perfusion to visceral arteries. Patients can develop abdominal pain and distention as a result of ischemia or thrombus formation. Visceral ischemia can lead to fatal organ damage before signs and symptoms are detected. If the patient develops ischemia, the IAB catheter will have to be removed Patients with an IABP are at increased risk for a dissecting aortic aneurysm and should be monitored for a blood pressure differential between the left and right sides of the body; an increase in blood pressure; pallor; dyspnea; pain in the chest, abdomen, or back; syncope;and diaphoresis IABP therapy may be placed on hold while troubleshooting the device; however, it is important that the balloon not remain dormant (i.e., not inflating/deflating) for > 15 minutes due to an increased risk for clot formation If the IABP console malfunctions, a new console must be immediately obtained, attached to the IAB catheter, and pumping continued as ordered

9 If unable to locate a new IABP console immediately, the IAB should be manually inflated/deflated every 5 minutes using a 60 cc syringe and a quantity of room air roughly 10 cc less than the maximum inflation volume printed on the catheter. Never manually inflate the IAB if balloon rupture suspected Balloon rupture is a life-threateningemergency. Balloon rupture is suspected if there is blood visible in the helium tubing or if there is a sudden cessation of inflation/deflation. If balloon rupture is suspected, the IAB catheter must be removed immediately to reduce the likelihood for fatal gas embolism occurring as a result of helium being pumped directly into the artery and infection with can occur because the gas chamber of the balloon is not sterile (for more information on balloon removal, see Nursing Practice & Skill... Intra-aortic Balloon Pump: Weaning from and Removing ) What Do I Need to Tell the Patient/Patient s Family? Explain how IABP therapy helps to support the patient s cardiovascular system and why it has been ordered for the patient Reinforce the need to not bend the leg or handle the IAB catheter Reassure that sedation and analgesia will be provided either routinely or as needed, according to treating clinician orders Provide information regarding the timeline for use of IABP therapy (e.g., until the patient s heart can function adequately or, if appropriate, until post-transplant weaning is successful) References 1. Arrow Teleflex. (2012). Proactive counterpulsation: Automatic timing accuracy even during arrhythmias. Morrisville, NC: Teleflex, Incorporated. Retrieved October 1, 2018, from (GI) 2. Chen, S., Yin, Y., Ling, Z., & Krucoff, M. W. (2014). Short and long term effect of adjunctive intra-aortic balloon pump use for patients undergoing high risk reperfusion therapy: A meta-analysis of 10 international randomised trials. Heart, 100(4), doi: /heartjnl (M) 3. de Jong, M. M., Lorusso, R., Al Awami, F., Matteuci, F., Parise, O., Lozekoot, P.,... Gelsomino, S. (2017). Vascular complications following intra-aortic balloon pump implantation: An updated review. Perfusion, 33(2), doi: / (SR) 4. Eckman, M. (Ed.). (2015). Intra-aortic balloon counterpulsation. In Lippincott nursing procedures (7th ed., pp ). Philadelphia, PA: Wolters Kluwer Health/Lippincott Williams & Wilkins. (PP) 5. Green, L., McClellan, E., Macapagal, F., & Bridges, C. (2015). Effects of mobilization on patients awaiting heart transplant with an intra-aortic balloon pump. Critical Care Nurse, 35(2), e72. (R) 6. Harper, J. P. (2017). Intraaortic balloon pump management. In D. L. Wiegand (Ed.), AACN procedure manual for high acuity, progressive, and critical care (7th ed., pp ). t. Louis, MO: Elsevier. (PP) 7. O'Gara, P. T., Kushner, F. G., Ascheim, D. D., Casey, D. E., Jr, Chung, M. K., de Lemos, J. A.,... Yancy, C. W. (2013) ACCF/AHA Guideline for the Management of ST-Elevation Myocardial Infarction: A Report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. Circulation, 127(4), e362-e425. doi: /cir.0b013e cf6 (G) 8. Parissis, H., Graham, V., Lampridis, S., Lau, M., Hooks, G., & Mhandu, P. C. (2016). IABP: History-evolution-pathophysiology-indications: What we need to know. Journal of Cardiothoracic Surgery, 11, 122. doi: /s (GI) 9. Patel, H., Shivaraju, A., Fonarow, G. C., Xie, H., Gao, W., Shroff, A. R., & Vidovich, M. I. (2014). Temporal trends in the use of intra-aortic balloon pump associated with percutaneous coronary intervention in the United States, American Heat Journal, 168(3), 363. doi: /j.ahj (R) 10. Poirier, Y., Voisine, P., Plourde, G., Rimac, G., Perez, A. B., Costerousse, O., & Bertrand, O. F. (2016). Efficacy and safety of preoperative intraaortic balloon pump use in patients undergoing cardiac surgery: A systematic review and meta-analysis. International Journal of Cardiology, 2017, doi: /j.ijcard (M)

Section 6 Intra Aortic Balloon Pump

Section 6 Intra Aortic Balloon Pump Section 6 Intra Aortic Balloon Pump The Intra Aortic Balloon Pump (IABP) The balloon is synthetic and is made for single use only. It is threaded into the aorta, usually via a femoral approach. The balloon

More information

Hemodynamic Monitoring and Circulatory Assist Devices

Hemodynamic Monitoring and Circulatory Assist Devices Hemodynamic Monitoring and Circulatory Assist Devices Speaker: Jana Ogden Learning Unit 2: Hemodynamic Monitoring and Circulatory Assist Devices Hemodynamic monitoring refers to the measurement of pressure,

More information

CSC Review Course: Intra Aortic Balloon Pump (IABP) Paula M Davis ARNP, MSN, CCRN-CSC

CSC Review Course: Intra Aortic Balloon Pump (IABP) Paula M Davis ARNP, MSN, CCRN-CSC CSC Review Course: Intra Aortic Balloon Pump (IABP) Paula M Davis ARNP, MSN, CCRN-CSC What is an IABP? The Intra-Aortic Balloon Counterpulsation system is a volume displacement device. It should be positioned

More information

IABP Timing & Fidelity. Pocket Reference Guide

IABP Timing & Fidelity. Pocket Reference Guide IABP Timing & Fidelity Pocket Reference Guide Correct IABP Timing A = One complete cardiac cycle R B = Unassisted aortic end diastolic pressure P T C = Unassisted systolic pressure D = Diastolic augmentation

More information

CLINICAL SUPPORT SERVICES DEVELOPING AN IABP PRECEPTOR STRATEGY

CLINICAL SUPPORT SERVICES DEVELOPING AN IABP PRECEPTOR STRATEGY CLINICAL SUPPORT SERVICES DEVELOPING AN IABP PRECEPTOR STRATEGY DATASCOPE IS NOW MAQUET CARDIOVASCULAR Datascope is now MAQUET Cardiovascular In early 2009, the purchase agreement between Datascope and

More information

2. Need for serial arterial blood gas determinations. 2. Anticipation of the initiation of thrombolytic therapy

2. Need for serial arterial blood gas determinations. 2. Anticipation of the initiation of thrombolytic therapy I. Subject: Arterial Cannulation II. Policy: Arterial cannulation will be performed upon a physician's order by Cardiopulmonary and Respiratory Therapy personnel certified in the arterial catheterization

More information

Useful? Definition of High-risk? Pre-OP/Intra-OP/Post-OP? Complication vs Benefit? Mortality? Morbidity?

Useful? Definition of High-risk? Pre-OP/Intra-OP/Post-OP? Complication vs Benefit? Mortality? Morbidity? Preoperative intraaortic balloon counterpulsation in high-risk CABG Stefan Klotz, M.D. Preoperative IABP in high-risk CABG Questions?? Useful? Definition of High-risk? Pre-OP/Intra-OP/Post-OP? Complication

More information

Competency Title: Caring for a patient with an arterial line

Competency Title: Caring for a patient with an arterial line Appendix 2 Competency Title: Caring for a patient with an arterial line Aims and objectives Following completion of this competency document the practitioner will be able to: Discuss the indications for

More information

CATCH A WAVE.. INTRODUCTION NONINVASIVE HEMODYNAMIC MONITORING 4/12/2018

CATCH A WAVE.. INTRODUCTION NONINVASIVE HEMODYNAMIC MONITORING 4/12/2018 WAVES CATCH A WAVE.. W I S C O N S I N P A R A M E D I C S E M I N A R A P R I L 2 0 1 8 K E R I W Y D N E R K R A U S E R N, C C R N, E M T - P Have you considered that if you don't make waves, nobody

More information

Critical Care Nursing Program August to November, 2015 Full-time Lesson A13 Pumping and Perfusion III Basic Hemodynamic Monitoring

Critical Care Nursing Program August to November, 2015 Full-time Lesson A13 Pumping and Perfusion III Basic Hemodynamic Monitoring Critical Care Nursing Program August to November, 2015 Full-time Lesson A13 Pumping and Perfusion III Basic Hemodynamic Monitoring August 2015 RN Professional Development Centre Page 1 Lesson Thirteen

More information

Images have been removed from the PowerPoint slides in this handout due to copyright restrictions.

Images have been removed from the PowerPoint slides in this handout due to copyright restrictions. Percutaneous Coronary Intervention https://www.youtube.com/watch?v=bssqnhylvma Types of PCI Procedures Balloon Angioplasty Rotational Atherectomy Coronary Stent Balloon Inflation Rotational Atherectomy

More information

The Role of Mechanical Circulatory Support in Cardiogenic Shock: When to Utilize

The Role of Mechanical Circulatory Support in Cardiogenic Shock: When to Utilize The Role of Mechanical Circulatory Support in Cardiogenic Shock: Presented by Nancy Scroggins ACNP, CNS-CC CV Surgery ACNP Bayshore Medical Center The Role of Mechanical Circulatory Support in Cardiogenic

More information

Principles of intra-aortic balloon pump counterpulsation

Principles of intra-aortic balloon pump counterpulsation Principles of intra-aortic balloon pump counterpulsation Murli Krishna MBBS FRCA FFPMRCA Kai Zacharowski MD PhD FRCA Key points The primary goal of intraaortic balloon pump (IABP) treatment is to increase

More information

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER Page 1 of 5 ASPIRATION CATHETER Carefully read all instructions prior to use, observe all warnings and precautions noted throughout these instructions. Failure to do so may result in complications. STERILE.

More information

CVICU EXAM. Mrs. Jennings is a 71-year-old post-op CABG x5 with an IABP in her left femoral artery

CVICU EXAM. Mrs. Jennings is a 71-year-old post-op CABG x5 with an IABP in her left femoral artery CVICU EXAM 1111 North 3rd Street Mrs. Jennings is a 71-year-old post-op CABG x5 with an IABP in her left femoral artery 1. Nursing standards for a patient on an IABP device include: a. Know results of

More information

Rhondalyn C. McLean. 2 ND YEAR RESEARCH ELECTIVE RESIDENT S JOURNAL Volume VII, A. Study Purpose and Rationale

Rhondalyn C. McLean. 2 ND YEAR RESEARCH ELECTIVE RESIDENT S JOURNAL Volume VII, A. Study Purpose and Rationale A Randomized Clinical Study To Compare The Intra-Aortic Balloon Pump To A Percutaneous Left Atrial-To-Femoral Arterial Bypass Device For Treatment Of Cardiogenic Shock Following Acute Myocardial Infarction.

More information

Cardiovascular Nursing Practice: A Comprehensive Resource Manual and Study Guide for Clinical Nurses 2 nd Edition

Cardiovascular Nursing Practice: A Comprehensive Resource Manual and Study Guide for Clinical Nurses 2 nd Edition Cardiovascular Nursing Practice: A Comprehensive Resource Manual and Study Guide for Clinical Nurses 2 nd Edition Table of Contents Volume 1 Chapter 1: Cardiovascular Anatomy and Physiology Basic Cardiac

More information

1/3/2008. Karen Burke Priscilla LeMone Elaine Mohn-Brown. Medical-Surgical Nursing Care, 2e Karen Burke, Priscilla LeMone, and Elaine Mohn-Brown

1/3/2008. Karen Burke Priscilla LeMone Elaine Mohn-Brown. Medical-Surgical Nursing Care, 2e Karen Burke, Priscilla LeMone, and Elaine Mohn-Brown Medical-Surgical Nursing Care Second Edition Karen Burke Priscilla LeMone Elaine Mohn-Brown Chapter 26 Caring for Clients with Coronary Heart Disease and Dysrhythmias Coronary Heart Disease (CHD) Leading

More information

Admission of patient CVICU and hemodynamic monitoring

Admission of patient CVICU and hemodynamic monitoring Admission of patient CVICU and hemodynamic monitoring Prepared by: Rami AL-Khatib King Fahad Medical City Pi Prince Salman Heart tcentre CVICU-RN Admission patient to CVICU Introduction All the patients

More information

Relax and Learn At the Farm 2012

Relax and Learn At the Farm 2012 Relax and Learn At the Farm Session 9: Invasive Hemodynamic Assessment and What to Do with the Data Carol Jacobson RN, MN Cardiovascular Nursing Education Associates Function of CV system is to deliver

More information

Modern Left Ventricular Assist Devices (LVAD) : An Intro, Complications, and Emergencies

Modern Left Ventricular Assist Devices (LVAD) : An Intro, Complications, and Emergencies Modern Left Ventricular Assist Devices (LVAD) : An Intro, Complications, and Emergencies ERIC T. ROME D.O. HEART FAILURE, MECHANICAL ASSISTANCE AND TRANSPLANTATION CVI Left Ventricular Assist Device An

More information

Cardiology. Objectives. Chapter

Cardiology. Objectives. Chapter 1:44 M age 1121 Chapter Cardiology Objectives art 1: Cardiovascular natomy and hysiology, ECG Monitoring, and Dysrhythmia nalysis (begins on p. 1127) fter reading art 1 of this chapter, you should be able

More information

Cath Lab Essentials : LV Assist Devices for Hemodynamic Support (IABP, Impella, Tandem Heart, ECMO)

Cath Lab Essentials : LV Assist Devices for Hemodynamic Support (IABP, Impella, Tandem Heart, ECMO) Cath Lab Essentials : LV Assist Devices for Hemodynamic Support (IABP, Impella, Tandem Heart, ECMO) Michael A. Gibson, MD Assistant Professor of Medicine University of California, Irvine Division of Cardiology

More information

NURSING PRACTICE & SKILL

NURSING PRACTICE & SKILL NURSING PRACTICE & SKILL ICD-9 93.5, 93.59 Authors Carita Caple, RN, BSN, MSHS Eliza Schub, RN, BSN Reviewers Jennifer Kornusky, RN, MS Nursing Practice Council Glendale Adventist Medical Center, Glendale,

More information

Cardiothoracic Fellow Expectations Division of Cardiac Anesthesia, Beth Israel Deaconess Medical Center

Cardiothoracic Fellow Expectations Division of Cardiac Anesthesia, Beth Israel Deaconess Medical Center The fellowship in Cardiothoracic Anesthesia at the Beth Israel Deaconess Medical Center is intended to provide the foundation for a career as either an academic cardiothoracic anesthesiologist or clinical

More information

Technique. Technique. Technique. Monitoring 1. Local anesthetic? Aseptic technique Hyper-extend (if radial)

Technique. Technique. Technique. Monitoring 1. Local anesthetic? Aseptic technique Hyper-extend (if radial) Critical Care Monitoring Hemodynamic Monitoring Arterial Blood Pressure Cannulate artery Uses 2 Technique Sites Locate artery, prep 3 1 Technique Local anesthetic? Aseptic technique Hyper-extend (if radial)

More information

CLINICAL CONSIDERATIONS FOR THE BUNNELL LIFE PULSE HIGH-FREQUENCY JET VENTILATOR

CLINICAL CONSIDERATIONS FOR THE BUNNELL LIFE PULSE HIGH-FREQUENCY JET VENTILATOR CLINICAL CONSIDERATIONS FOR THE BUNNELL LIFE PULSE HIGH-FREQUENCY JET VENTILATOR 801-467-0800 Phone 800-800-HFJV (4358) Hotline TABLE OF CONTENTS Respiratory Care Considerations..3 Physician Considerations

More information

Diastolic Augmentation with an External Pulsating Device To Treat Cardiogenic Shock

Diastolic Augmentation with an External Pulsating Device To Treat Cardiogenic Shock Diastolic Augmentation with an External Pulsating Device To Treat Cardiogenic Shock Nickolas Trubov, B.Sc., C.C.P. and Steven J. Phillips, M.D. Mercy Hospital, Des Moines, Iowa 50314 ABSTRACT An 80 cc

More information

Arterial Line Insertion Pre Reading

Arterial Line Insertion Pre Reading PROCEDURE ACCREDITATION THE CANBERRA HOSPITAL EMERGENCY DEPARTMENT Arterial Line Insertion Pre Reading Indications Requirement for continuous blood pressure monitoring (all patients on pressors, inotropes,

More information

Aortic Dissection Causes of Death

Aortic Dissection Causes of Death Aortic Dissection Causes of Death Rupture aorta 33.3% Unspecified 33.3% Neurological l deficit it 13.9% Visceral ischemia/kidney failure 11.5% Cardiac tamponade 7.9% (Circulation 2002;105:200-6) Medical

More information

HAEMODYNAMIC IN THE CATH LABORATORY INTRO TO BASICS

HAEMODYNAMIC IN THE CATH LABORATORY INTRO TO BASICS HAEMODYNAMIC IN THE CATH LABORATORY INTRO TO BASICS BY NOOR FADZLY ALIAS CARDIOVASCULAR TECHNOLOGIST NCL Department National Heart Institute Kuala Lumpur INTRODUCTION ROLES OF HAEMODYNAMIC MONITORING PURPOSE

More information

Complications of Acute Myocardial Infarction

Complications of Acute Myocardial Infarction Acute Myocardial Infarction Complications of Acute Myocardial Infarction Diagnosis and Treatment JMAJ 45(4): 149 154, 2002 Hiroshi NONOGI Director, Division of Cardiology and Emergency Medicine, National

More information

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER Page 1 of 5 NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER STERILE. SINGLE USE ONLY. Sterilized with ethylene oxide gas. Non pyrogenic. Do not resterilize. Do not use opened or damaged packages.

More information

Coronary angioplasty and stents

Coronary angioplasty and stents Tests and Procedures Coronary angioplasty and stents By Mayo Clinic Staff Coronary angioplasty (AN-jee-o-plas-tee), also called percutaneous coronary intervention, is a procedure used to open clogged heart

More information

Counterpulsation. John N. Nanas, MD, PhD. Professor and Head, 3 rd Cardiology Dept, University of Athens, Athens, Greece

Counterpulsation. John N. Nanas, MD, PhD. Professor and Head, 3 rd Cardiology Dept, University of Athens, Athens, Greece John N. Nanas, MD, PhD Professor and Head, 3 rd Cardiology Dept, University of Athens, Athens, Greece History of counterpulsation 1952 Augmentation of CBF Adrian and Arthur Kantrowitz, Surgery 1952;14:678-87

More information

ER REBOA Catheter. Instructions for Use

ER REBOA Catheter. Instructions for Use ER REBOA Catheter Instructions for Use Prytime Medical Devices, Inc. 229 N. Main Street Boerne, TX 78006, USA feedback@prytimemedical.com www.prytimemedical.com US 1 210 340 0116 U.S. and Foreign Patents

More information

Cardiac Emergencies. Jim Bennett Paramedic and Clinical Education Coordinator American Medical Response Spokane, Washington

Cardiac Emergencies. Jim Bennett Paramedic and Clinical Education Coordinator American Medical Response Spokane, Washington Cardiac Emergencies Jim Bennett Paramedic and Clinical Education Coordinator American Medical Response Spokane, Washington The Heart -------Aorta Pulmonary Veins---- Superior Vena Cava------ Right Atrium-----

More information

THE journal OF EXTRA-CORPOREAL TECHNOLOGY ABSTRACT

THE journal OF EXTRA-CORPOREAL TECHNOLOGY ABSTRACT Original Article Innovations in Intra-Aortic Balloon Pump Management: Computer Modem Technology John M. Ingram, BS, CCP Cedars Medical Center Miami, Florida Keywords: intra-aortic balloon pump; computer;

More information

RECOMMENDED INSTRUCTIONS FOR USE

RECOMMENDED INSTRUCTIONS FOR USE Rapid Exchange PTCA Dilatation Catheter RECOMMENDED INSTRUCTIONS FOR USE Available in diameters 1.25mm to 4.5mm and in lengths 09mm to 40mm Caution: This device should be used only by physicians trained

More information

Arrow AC3 Optimus Intra-Aortic Balloon Pump Greater precision with increased simplicity; an evolution in IABP performance

Arrow AC3 Optimus Intra-Aortic Balloon Pump Greater precision with increased simplicity; an evolution in IABP performance Arrow AC3 Optimus Intra-Aortic Balloon Pump Greater precision with increased simplicity; an evolution in IABP performance Unmatched simplicity, right from the start The AC3 Optimus Intra-Aortic Balloon

More information

Arrow AC3 Optimus Intra-Aortic Balloon Pump Greater precision with increased simplicity; an evolution in IABP performance

Arrow AC3 Optimus Intra-Aortic Balloon Pump Greater precision with increased simplicity; an evolution in IABP performance Arrow AC3 Optimus Intra-Aortic Balloon Pump Greater precision with increased simplicity; an evolution in IABP performance Optimized therapy even in the most challenging patient conditions When already-compromised

More information

Transcatheter Aortic Valve Implantation Procedure (TAVI)

Transcatheter Aortic Valve Implantation Procedure (TAVI) Page 1 of 5 Procedure (TAVI) Introduction Aortic stenosis (AS) is a common heart valve problem associated with heart failure and death. Surgical valve repair or replacement is recommended if AS patients

More information

Your heart is a muscular pump about the size of your fist, located

Your heart is a muscular pump about the size of your fist, located How Your Heart Works Your heart is a muscular pump about the size of your fist, located slightly to the left and behind your breastbone. Its function is to pump blood throughout your body. As your heart

More information

Can be felt where an artery passes near the skin surface and over a

Can be felt where an artery passes near the skin surface and over a 1 Chapter 14 Cardiovascular Emergencies 2 Cardiovascular Emergencies Cardiovascular disease has been leading killer of Americans since. Accounts for 1 of every 2.8 deaths Cardiovascular disease (CVD) claimed

More information

Nitroglycerin and Heparin Drip Interfacility Protocols

Nitroglycerin and Heparin Drip Interfacility Protocols Nitroglycerin and Heparin Drip Interfacility Protocols EMS Protocol This protocol applies to nitroglycerin and Heparin drips that are initiated at the transferring facility prior to transport and are not

More information

University of Florida Department of Surgery. CardioThoracic Surgery VA Learning Objectives

University of Florida Department of Surgery. CardioThoracic Surgery VA Learning Objectives University of Florida Department of Surgery CardioThoracic Surgery VA Learning Objectives This service performs coronary revascularization, valve replacement and lung cancer resections. There are 2 faculty

More information

PROBLEM SET 2. Assigned: February 10, 2004 Due: February 19, 2004

PROBLEM SET 2. Assigned: February 10, 2004 Due: February 19, 2004 Harvard-MIT Division of Health Sciences and Technology HST.542J: Quantitative Physiology: Organ Transport Systems Instructors: Roger Mark and Jose Venegas MASSACHUSETTS INSTITUTE OF TECHNOLOGY Departments

More information

Chapter 14. Cardiovascular Emergencies

Chapter 14. Cardiovascular Emergencies Chapter 14 Cardiovascular Emergencies Introduction (1 of 2) Cardiovascular disease has been leading killer of Americans since 1900. Accounts for 1 of every 2.8 deaths Introduction (2 of 2) EMS can help

More information

Chapter 14 Cardiovascular Emergencies Cardiovascular Emergencies Cardiovascular disease has been leading killer of Americans since.

Chapter 14 Cardiovascular Emergencies Cardiovascular Emergencies Cardiovascular disease has been leading killer of Americans since. 1 2 3 4 5 Chapter 14 Cardiovascular Emergencies Cardiovascular Emergencies Cardiovascular disease has been leading killer of Americans since. Accounts for 1 of every 2.8 deaths Cardiovascular disease (CVD)

More information

SARASOTA MEMORIAL HOSPITAL NURSING DEPARTMENT POLICY

SARASOTA MEMORIAL HOSPITAL NURSING DEPARTMENT POLICY PS1070 SARASOTA MEMORIAL HOSPITAL NURSING DEPARTMENT POLICY TITLE: ADMISSION/DISCHARGE CRITERIA: CARDIOVASCULAR INTENSIVE Job Title of Reviewer: Director, CVICU EFFECTIVE DATE: REVIEWED/REVISED DATE: POLICY

More information

AORTIC GRAFT INFECTION

AORTIC GRAFT INFECTION NURSING CARE Theresa O Keefe NUM Vascular Unit PAH Vascular infections are serious They are associated with high morbidity and mortality The primary cause of surgical wound infections is contamination

More information

DEMYSTIFYING VADs. Nicolle Choquette RN MN Athabasca University

DEMYSTIFYING VADs. Nicolle Choquette RN MN Athabasca University DEMYSTIFYING VADs Nicolle Choquette RN MN Athabasca University Objectives odefine o Heart Failure o VAD o o o o Post Operative Complications Acute Long Term Nursing Interventions What is Heart Failure?

More information

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use The SplitWire Percutaneous Transluminal Angioplasty Scoring Device Instructions for Use Contents Contains one (1) SplitWire device. Sterile. Sterilized with ethylene oxide gas. Radiopaque. For single use

More information

Central Venous Catheter Insertion: Assisting

Central Venous Catheter Insertion: Assisting Approved by: Central Venous Catheter Insertion: Assisting Gail Cameron Senior Director, Operations, Maternal, Neonatal & Child Health Programs Dr. Santiago Ensenat Medical Director, Neonatology Neonatal

More information

Policies & Procedures. RNSP - RN Procedure. I.D. Number: 1097

Policies & Procedures. RNSP - RN Procedure. I.D. Number: 1097 Policies & Procedures Title: ESOPHAGEAL TAMPONADE TUBE (MINNESOTA Tube) ASSISTING WITH INSERTION, CARE OF A PATIENT, ASSISTING WITH REMOVAL RNSP - RN Procedure I.D. Number: 1097 Authorization [x] Nursing

More information

Acute arterial embolism

Acute arterial embolism Acute arterial embolism Definition Thrombus come from heart or blood vessel or other embolus such as tumor,air gas or fat flow with blood stream and occlude distal limb or visceral arteries which causes

More information

Intraaortic Balloon Counterpulsation- Supportive Data for a Role in Cardiogenic Shock ( Be Still My Friend )

Intraaortic Balloon Counterpulsation- Supportive Data for a Role in Cardiogenic Shock ( Be Still My Friend ) Intraaortic Balloon Counterpulsation- Supportive Data for a Role in Cardiogenic Shock ( Be Still My Friend ) Stephen G. Ellis, MD Section Head, Interventional Cardiology Professor of Medicine Cleveland

More information

Pre-operative usage of IABP for patients for by pass surgery

Pre-operative usage of IABP for patients for by pass surgery Pre-operative usage of IABP for patients for by pass surgery Mitrev Z, Anguseva T, Hristov N Special hospital for surgery Filip Vtori Skopje - Macedonija Oktomvri, 2008 IABP Background Preload Afterload

More information

Cardiovascular Practice Quiz

Cardiovascular Practice Quiz Cardiovascular Practice Quiz 1. When caring for a patient following a cardiac catheterization with coronary angiography, which of the following findings would be of most concern to the nurse? a. Swelling

More information

12/19/2017. Learning Objectives. Mechanical Circulatory Support. Mechanical Aids to External Massage. Noninvasive Mechanical Support Devices

12/19/2017. Learning Objectives. Mechanical Circulatory Support. Mechanical Aids to External Massage. Noninvasive Mechanical Support Devices Learning Objectives Mechanical Circulatory Support Explain the indications, function, & complications for selected mechanical circulatory support devices Describe examples of ventricular assist devices

More information

Parkland Health & Hospital System Women & Infant Specialty Health

Parkland Health & Hospital System Women & Infant Specialty Health Parkland Health & Hospital System Women & Infant Specialty Health NS 1700.04 Nursery Services Procedure Manual Arterial Puncture Practice Statement Upon the written order of the provider, the credentialled

More information

SARASOTA MEMORIAL HOSPITAL

SARASOTA MEMORIAL HOSPITAL SARASOTA MEMORIAL HOSPITAL TITLE: NURSING PROCEDURE PACEMAKERS AND DETERMINING PACEMAKER DATE: REVIEWED: PAGES: 10/99 11/18 1 of 7 PS1094 ISSUED FOR: Nursing RESPONSIBILITY: *Qualified RN PURPOSE: To establish

More information

CY2015 Hospital Outpatient: Endovascular Procedure APCs and Complexity Adjustments

CY2015 Hospital Outpatient: Endovascular Procedure APCs and Complexity Adjustments CY2015 Hospital Outpatient: Endovascular Procedure APCs Complexity Adjustments Comprehensive Ambulatory Payment Classifications (c-apcs) CMS finalized the implementation of 25 Comprehensive APC to further

More information

UNIVERSITY OF UTAH HEALTH CARE HOSPITALS AND CLINICS

UNIVERSITY OF UTAH HEALTH CARE HOSPITALS AND CLINICS UNIVERSITY OF UTAH HEALTH CARE HOSPITALS AND CLINICS CARDIAC MECHANICAL SUPPORT PROGRAM GUIDELINES CARDIAC MECHANICAL SUPPORT: LVAD BASICS FREQUENT SCENARIOS AND TROUBLESHOOTING Review Date: July 2011

More information

Acute heart failure: ECMO Cardiology & Vascular Medicine 2012

Acute heart failure: ECMO Cardiology & Vascular Medicine 2012 Acute heart failure: ECMO Cardiology & Vascular Medicine 2012 Lucia Jewbali cardiologist-intensivist 14 beds/8 ICU beds Acute coronary syndromes Heart failure/ Cardiogenic shock Post cardiotomy Heart

More information

Abdominal Exam: The examination of the abdomen used by physicians to detect an abdominal aortic aneurysm.

Abdominal Exam: The examination of the abdomen used by physicians to detect an abdominal aortic aneurysm. Glossary of Terms Abdominal Exam: The examination of the abdomen used by physicians to detect an abdominal aortic aneurysm. Angiogram: A diagnostic test requiring the insertion of a catheter into an artery

More information

Ventricular Assisting Devices in the Cathlab. Unrestricted

Ventricular Assisting Devices in the Cathlab. Unrestricted Ventricular Assisting Devices in the Cathlab Unrestricted What is a VAD? A single system device that is surgically attached to the left ventricle of the heart and to the aorta for left ventricular support

More information

Intended Learning Outcomes

Intended Learning Outcomes 2011 Acute Limb Ischemia Definition, Etiology & Pathophysiology Clinical Evaluation Management Ali SABBOUR Prof. of Vascular Surgery, Ain Shams University Acute Limb Ischemia Intended Learning Outcomes

More information

Assist Devices in STEMI- Intra-aortic Balloon Pump

Assist Devices in STEMI- Intra-aortic Balloon Pump Assist Devices in STEMI- Intra-aortic Balloon Pump Ioannis Iakovou, MD, PhD Onassis Cardiac Surgery Center Athens, Greece Cardiogenic shock 5-10% of pts after a heart attack 60000-70000 pts in Europe/year

More information

MONITORING PATIENTS WITH A TEMPORARY EXTERNAL EPICARDIAL PACEMAKER PURPOSE POLICY STATEMENTS SITE APPLICABILITY PRACTICE LEVEL/COMPETENCIES

MONITORING PATIENTS WITH A TEMPORARY EXTERNAL EPICARDIAL PACEMAKER PURPOSE POLICY STATEMENTS SITE APPLICABILITY PRACTICE LEVEL/COMPETENCIES PURPOSE Guidelines for caring for and monitoring patients with a temporary external epicardial pacemaker. Epicardial pacemaker monitoring is performed on a continuous basis by a nurse to evaluate the effectiveness

More information

ATI Skills Modules Checklist for Central Venous Access Devices

ATI Skills Modules Checklist for Central Venous Access Devices For faculty use only Educator s name Score Date ATI Skills Modules Checklist for Central Venous Access Devices Student s name Date Verify order Patient record Assess for procedure need Identify, gather,

More information

Nursing Process Focus: Patients Receiving Heparin

Nursing Process Focus: Patients Receiving Heparin Obtain complete heath history including allergies, drug history and possible drug Assess baseline coagulation studies and CBC. Assess for history of bleeding disorders, GI bleeding, cerebral bleed, recent

More information

Post-Cardiac Surgery Evaluation

Post-Cardiac Surgery Evaluation Post-Cardiac Surgery Evaluation 20th Annual Heart Conference October 15, 2016 Gary A Mayman PROFESSOR PEDIATRICS UNIVERSITY OF NEVADA Look Touch Listen Temperature, pulse, respiratory rate, & blood pressure

More information

Mary Lou Garey MSN EMT-P MedFlight of Ohio

Mary Lou Garey MSN EMT-P MedFlight of Ohio Mary Lou Garey MSN EMT-P MedFlight of Ohio Function Prolonged and frequent access to venous circulation Allows for patient to carry on normal life; decrease number of needle sticks Medications, parenteral

More information

BACHELOR OF SCIENCE IN CARDIO VASCULAR TECHNOLOGY

BACHELOR OF SCIENCE IN CARDIO VASCULAR TECHNOLOGY BACHELOR OF SCIENCE IN CARDIO VASCULAR TECHNOLOGY BCVT 101 Eco Cardiography BCVT 102 ECG-Stream-Holter BCVT 103 Cat lab BCVT 104 Anatomy 1 st YEAR BCVT 105 Physiology BCVT 106 Pathology & Pathophysiology

More information

Peripheral and Cardiology Coder 2018

Peripheral and Cardiology Coder 2018 Peripheral and Cardiology Coder 2018 Cardiovascular Services and Procedures Prepared and Published By: MedLearn Publishing A Division of MedLearn Media, Inc. 445 Minnesota Street, Suite 514 St. Paul, MN

More information

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE. MEASURING BLOOD PRESSURE - MANUAL (equ04)

SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE. MEASURING BLOOD PRESSURE - MANUAL (equ04) SARASOTA MEMORIAL HOSPITAL NURSING PROCEDURE TITLE: ISSUED FOR: MEASURING BLOOD PRESSURE - MANUAL Nursing DATE: REVIEWED: PAGES: 2/80 7/17 1 of 5 RESPONSIBILITY: RN, LPN, Patient Care Technician Multi-skilled

More information

Indications of Coronary Angiography Dr. Shaheer K. George, M.D Faculty of Medicine, Mansoura University 2014

Indications of Coronary Angiography Dr. Shaheer K. George, M.D Faculty of Medicine, Mansoura University 2014 Indications of Coronary Angiography Dr. Shaheer K. George, M.D Faculty of Medicine, Mansoura University 2014 Indications for cardiac catheterization Before a decision to perform an invasive procedure such

More information

Cardiac Catheterization Lab Procedures

Cardiac Catheterization Lab Procedures Patient Education Cardiac Catheterization Lab Procedures This booklet describes cardiac catheterization. It also details how to prepare for the procedure and the care needed after it is done. Before You

More information

Intravascular Ultrasound

Intravascular Ultrasound Scan for mobile link. Intravascular Ultrasound Intravascular ultrasound (IVUS) uses a transducer or probe to generate sound waves and produce pictures of the coronary arteries. IVUS can show the entire

More information

Diagnostic & Therapeutic Cardiac Catheterization Coder 2017

Diagnostic & Therapeutic Cardiac Catheterization Coder 2017 Diagnostic & Therapeutic Cardiac Catheterization Coder 2017 Including peripheral and cardiovascular services and procedures Prepared and Published By: MedLearn Publishing A Division of Panacea Healthcare

More information

Coronary angiography and PCI

Coronary angiography and PCI Coronary arteries Coronary angiography and PCI Samo Granda, Franjo Naji Department of Cardiology Clinical department of internal medicine University clinical centre Maribor Coronary arteries Atherosclerosis

More information

STATE OF OKLAHOMA 2014 EMERGENCY MEDICAL SERVICES PROTOCOLS

STATE OF OKLAHOMA 2014 EMERGENCY MEDICAL SERVICES PROTOCOLS 5M VENTRICULAR ASSIST DEVICE (VAD) MANAGEMENT ADULT EMERGENCY MEDICAL DISPATCHER EMERGENCY MEDICAL RESPONDER EMT EMT-INTERMEDIATE 85 ADVANCED EMT PARAMEDIC A Ventricular Assist Device, or VAD, is a mechanical

More information

LINEAR. 7.5Fr. IAB CATHETER INSTRUCTIONS FOR USE. INSTRUCTIONS FOR USE LINEAR 7.5Fr. Intra-Aortic Balloon Catheter 1

LINEAR. 7.5Fr. IAB CATHETER INSTRUCTIONS FOR USE. INSTRUCTIONS FOR USE LINEAR 7.5Fr. Intra-Aortic Balloon Catheter 1 LINEAR 7.5Fr. IAB CATHETER INSTRUCTIONS FOR USE Read this entire booklet before opening inner pack. INSTRUCTIONS FOR USE LINEAR 7.5Fr. Intra-Aortic Balloon Catheter 1 INTENDED USE The intra-aortic balloon

More information

HOW TO PERFORM LEFT VENTRICULAR ASSISTANCE IN THE CATHLAB. Andreas Baumbach, MD FESC FRCP Bristol Heart Institute University Hospitals Bristol UK

HOW TO PERFORM LEFT VENTRICULAR ASSISTANCE IN THE CATHLAB. Andreas Baumbach, MD FESC FRCP Bristol Heart Institute University Hospitals Bristol UK HOW TO PERFORM LEFT VENTRICULAR ASSISTANCE IN THE CATHLAB Andreas Baumbach, MD FESC FRCP Bristol Heart Institute University Hospitals Bristol UK Disclosure I have no conflicts of interest regarding this

More information

SEMINOLE COUNTY EMS PROVISIONAL EMT SKILLS VERIFICATION

SEMINOLE COUNTY EMS PROVISIONAL EMT SKILLS VERIFICATION The following individual has completed the Seminole County EMS Provisional EMT Skills Verification check in the following areas: Oxygen, Airway and Ventilation Skills ALS Assistance Trauma Management Medical

More information

C1: Medical Standards for Safety Critical Workers with Cardiovascular Disorders

C1: Medical Standards for Safety Critical Workers with Cardiovascular Disorders C1: Medical Standards for Safety Critical Workers with Cardiovascular Disorders GENERAL ISSUES REGARDING MEDICAL FITNESS-FOR-DUTY 1. These medical standards apply to Union Pacific Railroad (UPRR) employees

More information

SENSATION and CS300 Smaller meets faster. IABP System

SENSATION and CS300 Smaller meets faster. IABP System SENSATION and CS300 Smaller meets faster IABP System Cardiac Assist SENSATION and CS300 3 Cardiac Assist SENSATION and CS300 5 Smaller The SENSATION 7Fr. Fiber-Optic IAB Catheter Faster The CS300 with

More information

Guide to Cardiology Care at Scripps

Guide to Cardiology Care at Scripps Guide to Cardiology Care at Scripps Cardiology is the word in health care associated with heart, but the body s vascular system is also an important part of heart care. Your body has more than 60,000 miles

More information

Patient guide: pfm Nit-Occlud PDA coil occlusion system. Catheter occlusion of. Patent Ductus Arteriosus. with the

Patient guide: pfm Nit-Occlud PDA coil occlusion system. Catheter occlusion of. Patent Ductus Arteriosus. with the Patient guide: Catheter occlusion of Patent Ductus Arteriosus with the pfm Nit-Occlud PDA coil occlusion system pfm Produkte für die Medizin - AG Wankelstr. 60 D - 50996 Cologne Phone: +49 (0) 2236 96

More information

From Recovery to Transplant: One Patient's Journey

From Recovery to Transplant: One Patient's Journey From Recovery to Transplant: One Patient's Journey Tonya Elliott, RN, MSN Assist Device and Thoracic Transplant Coordinator Inova Transplant Center at Inova Fairfax Hospital Falls Church, VA Introduction

More information

Cardiovascular System

Cardiovascular System Cardiovascular System angio BELLWORK Day One: Define using technology hemo/hema cardio Medical Therapeutics Standards 11) Outline the gross normal structure and function of all body systems and summarize

More information

Unit 1: Human Systems. The Circulatory System

Unit 1: Human Systems. The Circulatory System Unit 1: Human Systems The Circulatory System nourish all cells with oxygen, glucose, amino acids and other nutrients and carry away carbon dioxide, urea and other wastes Purposes Transport chemical messengers

More information

LeMone & Burke Ch 30-32

LeMone & Burke Ch 30-32 LeMone & Burke Ch 30-32 2 Right side- Low oxygenation Low pressure Light workload Goes toward the lungs Left side High oxygenation Thick walled high pressure Heavier workload Carries oxygenation blood

More information

Ultrasound-enhanced, catheter-directed thrombolysis for pulmonary embolism

Ultrasound-enhanced, catheter-directed thrombolysis for pulmonary embolism NATIONAL INSTITUTE FOR HEALTH AND CARE EXCELLENCE Interventional procedure consultation document Ultrasound-enhanced, catheter-directed thrombolysis for pulmonary embolism A pulmonary embolism (PE) is

More information

Title and contents page 1 Who should read this document 2 Scope of the Guideline 2 Background 2 What is new in this version 2

Title and contents page 1 Who should read this document 2 Scope of the Guideline 2 Background 2 What is new in this version 2 Temporary Transvenous Pacing Guideline Classification: Clinical Guideline Lead Author: Dr Peter Woolfson Additional author(s): Dr Alan Fitchet Sister Joanne Hughes, Matron Julie Winstanley Authors Division:

More information

Routine, Every 2 hours, Starting today, If temperature greater than 38.5 C initiate Evaluation for Possible Sepsis Physician Order #829

Routine, Every 2 hours, Starting today, If temperature greater than 38.5 C initiate Evaluation for Possible Sepsis Physician Order #829 Height Weight Allergies General Vital Signs [X] Frequent vital signs Indication: Q15 minutes x (# of occurrences): 4 Q30 minutes x (# of occurrences): 4 Q1 hour x (# of occurrences): Q2 hours x (# of occurrences):

More information

Diagnosis and Management of Acute Myocardial Infarction

Diagnosis and Management of Acute Myocardial Infarction Diagnosis and Management of Acute Myocardial Infarction Acute Myocardial Infarction (AMI) occurs as a result of prolonged myocardial ischemia Atherosclerosis leads to endothelial rupture or erosion that

More information

Chp. 5 The cardiovascular system. What are the function of the cardiovascular system? Arteries and arterioles:

Chp. 5 The cardiovascular system. What are the function of the cardiovascular system? Arteries and arterioles: 5.1 Overview of the cardiovascular system Chp. 5 The cardiovascular system Includes the heart and blood vessels Brings nutrients to cells and helps get rid of wastes Blood is refreshed in the lung, kidneys,

More information

Cheltenham General Hospital

Cheltenham General Hospital Page 1 of 5 Coronary angioplasty Introduction This leaflet provides information for patients undergoing coronary angioplasty also known as PCI (Percutaneous Coronary Intervention). What is coronary artery

More information