LD TECHNOLOGY PRODUCT CATALOG

Size: px
Start display at page:

Download "LD TECHNOLOGY PRODUCT CATALOG"

Transcription

1 LD TECHNOLOGY M A K I N G A D I F F E R E N C E EARLY DETECTION OF DIABETES COMPLICATIONS AUTONOMIC NERVOUS SYSTEM AND ARTERY ASSESSEMENT BLOOD PRESSURE AND ARTERIAL STIFFNESS ANALYSIS Monitoring and Treatment Management of Hypertension HEART RATE VARIABILITY (HRV) Cardiac Autonomic Dysfunction Assessment PHOTOPLETHYSMOGRAPHY Microcirculation disorders are the earlier stages of artery and Autonomic Nervous System complications CARDIAC AUTONOMIC REFLEX TESTS (CARTs) Cardiac Autonomic Neuropathy Assessment ANKLE BRACHIAL INDEX (ABI) Peripheral Artery Disease. Artery Blood Flow blockage or Calcification SUDOMOTOR FUNCTION TESTS Small Fiber Neuropathy Assessment LD TECHNOLOGY PRODUCT CATALOG

2 MAIN SYMPTOMS OF AUTONOMIC NERVE AND ARTERY DYSFUNCTION / DAMAGE Fatigue Headache Dizziness Exercice Intolarance Fainting Tingling in the Toes or Fingers Claudication Paintful muscle cramping in the hips, thighs or calves when walking, climbing stairs or exercising POPULATIONS THAT SHOULD BE TESTED WITH LD PRODUCTS Autonomic nerves and artery damage risk group in the USA Population over 50 years old with cardiovascular risk factors (Hypertensive, Overweight, Smoker, Diabetic) Everyone older than 70 OVER 45 MILLION PEOPLE EVERYONE IN THE RISK GROUP SHOULD BE MEASURED WITH LD PRODUCTS

3 TM-FLOW ARTERY / AUTONOMIC NERVES ARTERY ASSESSMENT AUTONOMIC NERVOUS SYSTEM ASSESSMENT LD-OXY OXIMETER FEET ELECTRODES TM-F l ow is focused on th e a u t o n o m i c n e r vo us s ys t e m a n d v a sc u la r sy st em f o r t h e ea r ly d etec t i o n a n d mo n i t o r i n g of com pl ication s res ul ting from chronic dis ea s e s, s uc h a s Di a b e t e s. PATIENT SETUP

4 TM-FLOW MARKERS ARTERY ASSESSMENT : ANS ASSESSMENT : Photoplethysmography (PTG) analysis Volume plethysmography analysis Second derivative PTG Pulse Wave Velocity (PWV) Peripheral Augmentation Index (paix) Central Aortic Systolic Pressure (CASP) Ankle Brachial Indices (ABI) Toe Brachial Index (TBI) Sudomotor markers Peak sweat gland blood flow and density Heart Rate Variability Analysis (HRV) Total Power, SDANN, LF, HF and LF/HF Cardiac Autonomic Reflex Tests (CARTs) Valsalva Ratio, E/I Ratio, K30/15 Ratio and Systolic blood pressure response difference while standing MICROCIRCULATION DISORDERS X PERIPHERAL ARTERY DISEASE X SUDOMOTOR DYSFUNCTION X CARDIAC AUTONOMIC NEUROPATHY BENEFITS OF TM-FLOW SYSTEM No Human Error Clear report Accurate Results (Simultaneous measurements) 7-10 min ANS and Artery Overview Combinaison of Technologies TM-FLOW is the only available medical device for assessing the Autonomic Nervous System and Arteries in one simultaneous exam. It helps the physician to distinguish the cause of neuropathic or vascular symptoms. Although the symptoms may imitate each other, it is imperative to distinguish between Autonomic Neuropathy and Artery Disease because the treatments are quite different. TM-FLOW performs accurate, simultaneous measurements that are based on established medical guidelines without any extrapolation of the results.

5 TM-FLOW TECHNICAL SPECIFICATIONS TM-FLOW is a Medical Device Data System (MDDS) which manages the SweatC, TM-ABI and LD-OXY Systems. FDA product code: OUG. Measuring principle SWEATC Galvanic skin response Voltage Intensity Measuring Range Maximum 1.28 V Maximum 200 ma SWEATC (a.k.a.sudoc) Galvanic Skin Response related to the sweat gland function. Measuring Accuracy The max mean deviation ± 3% 510k # k Power requirements Supply voltage 5V via USB port Measuring types Measuring ranges TM-ABI Ankle Brachial pressure index using volume plethysmography method for measuring systolic and diastolic pressure at arm and ankles. Pressure: 0 to 299 mmhg Heart rate 30 to 199 per min. TM-ABI Volume Plethysmography for assessing symtomatic peripheral artery disease. 510k # k LD-OXY SpO₂ Parameter Specification Measuring range 0%~100% (the resolution is 1%) Measuring range Photoplethysmography resolution: 100 ms Pulse Parameter Specification Measuring ranges 30 bpm ~ 250 bpm, (the resolution is 1bpm) LD-OXY Photoplethysmography analysis, HRV and CARTs analysis. 510k # k Accuracy ± 2bpm during the pulse rate range of 30 ~ 99bpm and 2% during pulse rate range of 100 ~ 250bpm

6 TM-ABI PLUS ARTERY PERIPHERAL ARTERY DISEASE ASSESSMENT The TM-ABI is the first valuable automated ankle-brachial index measuring system based on volume plethysmography for measuring blood pressure, ankle brachial and toe brachial index, arterial stiffness and central aortic Pressure. PATIENT SETUP

7 TM-ABI PLUS MARKERS ARTERY ASSESSMENT : Volume plethysmography analysis: Arm and Ankles Blood Pressure Pulse Wave Velocity (PWV) Peripheral Augmentation Index (paix) Central Aortic Systolic Pressure (CASP) Ankle Brachial Indices (ABI) Toe Brachial Index (TBI) PERIPHERAL ARTERY DISEASE BENEFITS OF TM-ABI PLUS No Human Error Clear report Accurate Results (Simultaneous measurements) 2-3 min ANS and Artery Overview Combinaison of Technologies TM-ABI PLUS detects all the markers of hypertension in addition to the Brachial Blood Pressure. The device provides Brachial and Ankle Arterial Stiffness and Central Aortic Systolic Pressure. ALLOWS NEW AND EFFECTIVE TREATMENT MANAGEMENT OF HYPERTENSION Best method to assess peripheral artery disease using: - Synchronization of the measurements arm-ankles - Blood pressure measurement from Photoplethysmography - Toe Brachial Index is a requirement to assess PAD in cases of ABI results >=1.4

8 TM-ABI PLUS TECHNICAL SPECIFICATIONS TM-ABI PLUS is a Medical Device Data System (MDDS) which manages the TM-ABI and LD-OXY Systems. FDA product code: OUG. TM-ABI Measuring types Measuring ranges Ankle Brachial pressure index using volume plethysmography method for measuring systolic and diastolic pressure at arm and ankles. Pressure: 0 to 299 mmhg Heart rate 30 to 199 per min. TM-ABI Volume Plethysmography for assessing symtomatic peripheral artery disease. 510k # k LD-OXY SpO₂ Parameter Specification Measuring range 0%~100% (the resolution is 1%) Measuring range Photoplethysmography resolution: 100 ms Pulse Parameter Specification Measuring ranges 30 bpm ~ 250 bpm, (the resolution is 1bpm) LD-OXY Photoplethysmography analysis, HRV and CARTs analysis. 510k # k Accuracy ± 2bpm during the pulse rate range of 30 ~ 99bpm and 2% during pulse rate range of 100 ~ 250bpm

9 ANS-1 AUTONOMIC NERVES AUTONOMIC NERVOUS SYSTEM ASSESSMENT OXIMETER FEET ELECTRODES ANS-1 system manages the Sudomotor test, Heart Rate Variability (HRV) Analysis at rest and during the Ewings tests in order to provide an overview of Automic nervous System. PATIENT SETUP

10 ANS-1 MARKERS ARTERY ASSESSMENT : ANS ASSESSMENT : Photoplethysmography (PTG) analysis Sudomotor function markers Conductance at anode and cathode following a DC stimulation Heart Rate Variability Analysis (HRV) Cardiac Autonomic Reflex Tests (CARTs) Valsalva Raio, E/I Ratio, K30/15 Ratio, Systolic response difference while standing MICROCIRCULATION DISORDERS X SUDOMOTOR DYSFUNCTION X CARDIAC AUTONOMIC NEUROPATHY BENEFITS OF ANS-1 No Human Error Clear report Accurate Results (Simultaneous measurements) 7-10 min ANS and Artery Overview ANS-1 System manages the Autonomic Nervous System battery of tests recommended by the American Academy of Neurology since 1996, and the Cardiovascular Autonomic Neuropathy Subcommittee of the Toronto Consensus Panel on Diabetic Neuropathy, for assessing the Autonomic Nervous System. Autonomic testing is recommended for all patients with type 2 diabetes at the time of the diagnosis, and 5 years after diagnosis in individuals with type 1 diabetes. ( Boulton et al., 2005;Tesfaye et al., 2010;Spallone et al., 2011; Bernardi et al.,2011.)

11 ANS-1 TECHNICAL SPECIFICATIONS ANS-1 is a Medical Device Data System (MDDS) which manages a unique Galvanic Skin response device, an oximeter and non-invasive blood pressure device. FDA product code: DXN, DQA, GZO and MNW. GALVANIC SKIN RESPONSE Measuring principle Galvanic skin response Measuring Range Voltage Intensity Maximum 1.28 V Maximum 200 ma Measuring Accuracy The max mean deviation ± 3% Power requirements Supply voltage 5V via USB port BLOOD PRESSURE DEVICE Measuring types Ankle Brachial pressure index using oscillometric method. Measuring ranges Pressure: 0 to 299 mmhg. ANS-1 SYSTEM Sudomotor function, HRV and CARTs Analysis and Photoplethysmography 510k # k OXIMETER SpO₂ Parameter Specification Measuring range Measuring range 0%~100% (the resolution is 1%) Photoplethysmography resolution: 100 ms Pulse Parameter Specification Measuring ranges Accuracy 30 bpm ~ 250 bpm, (the resolution is 1bpm) ± 2bpm during the pulse rate range of 30 ~ 99bpm and 2% during pulse rate range of 100 ~ 250bpm

12 LD TECHNOLOGY M A K I N G A D I F F E R E N C E LD TECHNOLOGY ISO CAMCAS FDA OWNER/OPERATOR NUMBER: FDA ESTABLISHMENT REGISTRATION NUMBER: CONTACT LD TECHNOLOGY ADDRESS 100 N. BISCAYNE BLVD, SUITE MIAMI, FLORIDA UNITED STATES

LD TECHNOLOGY PRODUCT CATALOG

LD TECHNOLOGY PRODUCT CATALOG LD TECHNOLOGY M A K I N G A D I F F E R E N C E EARLY DETECTION OF DIABETES COMPLICATIONS AUTONOMIC NERVOUS SYSTEM AND VASCULAR FUNCTION ASSESSMENTS BLOOD PRESSURE AND ARTERIAL STIFFNESS ANALYSIS Monitoring

More information

EARLY DETECTION OF DIABETES COMPLICATIONS AUTONOMIC NERVOUS SYSTEM AND VASCULAR FUNCTION ASSESSMENTS

EARLY DETECTION OF DIABETES COMPLICATIONS AUTONOMIC NERVOUS SYSTEM AND VASCULAR FUNCTION ASSESSMENTS HIGHLY REIMBURSABLE M A K I N G A D I F F E R E N C E EARLY DETECTION OF DIABETES COMPLICATIONS AUTONOMIC NERVOUS SYSTEM AND VASCULAR FUNCTION ASSESSMENTS BLOOD PRESSURE AND ARTERIAL STIFFNESS ANALYSIS

More information

ARTERIAL STIFFNESS ASSESSMENT COMMENTS:

ARTERIAL STIFFNESS ASSESSMENT COMMENTS: ARTERIAL STIFFNESS ASSESSMENT 10% Low small artery stiffness risk. However, we detect mild vasoconstriction in small artery. No large arterial stiffness has been detected. High Blood Pressure & Arterial

More information

ANS1 : Sudopath & TM Oxi

ANS1 : Sudopath & TM Oxi ANS1 : Sudopath & TM Oxi Assessment of: Autonomic Nervous System Cardiovascular System Sudomotor Function Endothelial (arterial) Function Clinical Applications: Early Detection of risk for Peripheral Small

More information

SUMMARY REPORT. Autonomic Nervous System Function. Valsalva 100

SUMMARY REPORT. Autonomic Nervous System Function. Valsalva 100 SUMMARY REPORT Nervous System Function 8 Heart Rate (red) & Blood Pressure (blue) Parasympathetic Balance Sympathetic hypertonia 4 [bpm] Resting Deep Breathing Valsalva Standing Relaxation Balance Stress.

More information

Identifying Autonomic Neuropathy and Endothelial Dysfunction in Type II Diabetic Patients

Identifying Autonomic Neuropathy and Endothelial Dysfunction in Type II Diabetic Patients Cronicon OPEN ACCESS NEUROLOGY Research Article Albert Maarek 1 *, Pratiksha G Gandhi 2 and Pr Gundu HR Rao 3 1 Research and development LD Technology, USA 2 Cardiologist, India 3 University of Minnesota,

More information

QANS ASSESSMENT SYSTEM

QANS ASSESSMENT SYSTEM Comprehensive Non Invasive System Includes: Autonomic Balance Analysis Cardiovascular Pulse Wave Velocity Analysis ECG Analysis Cardiovascular Fitness Analysis Metabolic Report Arterial Vascular Assessment

More information

RM-3A Cardiovascular & ANS Medical Device

RM-3A Cardiovascular & ANS Medical Device RM-3A Cardiovascular & ANS Medical Device The RM-3A medical device is a powerful analytical tool in managing your patients health. Scientifically validated and FDA cleared, this medical device performs

More information

ESTECK Status Report [Abridged]

ESTECK Status Report [Abridged] Back www.geoffbond.com ESTECK Status Report [Abridged] WARNING! The ES Teck system [] does not replace any existing other medical examinations. The ES Teck system[] is not used for diagnosis. It is intended

More information

Managing cardiovascular risk with SphygmoCor XCEL

Managing cardiovascular risk with SphygmoCor XCEL Managing cardiovascular risk with SphygmoCor XCEL Central pulse pressure better predicts outcome than does brachial pressure Roman et al., Hypertension, 2007; 50:197-203 Carotid to femoral Pulse Wave Velocity

More information

World s Fastest Ankle-Brachial Index Screening Device

World s Fastest Ankle-Brachial Index Screening Device World s Fastest Ankle-Brachial Index Screening Device Accurate and objective Peripheral Arterial Disease diagnosis E S S E N T I A L T O H E A LT H NOTE: Brošura - A4 format na poli A3 What is Peripheral

More information

with SERIES ANALYTICAL SYSTEM Clinical, Billing & Orientation Reference Guide

with SERIES ANALYTICAL SYSTEM Clinical, Billing & Orientation Reference Guide with SERIES ANALYTICAL SYSTEM Clinical, Billing & Orientation Reference Guide RM-3A Series Analytical System INTRODUCTION Thank you for purchasing your RM-3A Series Analytical System (RM-3A SAS)! We appreciate

More information

VitalScan Plus. Autonomic Dysfunction Assessment. VitalScan + In 15 Minutes Identify Patients at Risk. Medeia Inc

VitalScan Plus. Autonomic Dysfunction Assessment. VitalScan + In 15 Minutes Identify Patients at Risk. Medeia Inc VitalScan Plus Medeia Inc Autonomic Dysfunction Assessment In 15 Minutes Identify Patients at Risk The VitalScan diagnostic test provides next generation non invasive patient diagnostics within minutes.

More information

Imaging for Peripheral Vascular Disease

Imaging for Peripheral Vascular Disease Imaging for Peripheral Vascular Disease James G. Jollis, MD Director, Rex Hospital Cardiovascular Imaging Imaging for Peripheral Vascular Disease 54 year old male with exertional calf pain in his right

More information

World s Fastest Ankle-Brachial Index Screening Device

World s Fastest Ankle-Brachial Index Screening Device World s Fastest Ankle-Brachial Index Screening Device Accurate and objective Peripheral Arterial Disease diagnosis From secondary to primary healthcare with the help of technology. MESI founders identified

More information

Managing anti-hypertensive treatment with SphygmoCor XCEL

Managing anti-hypertensive treatment with SphygmoCor XCEL Managing anti-hypertensive treatment with SphygmoCor XCEL Measurement of Central aortic BP may provide valuable information on antihypertensive drug action that is not apparent with assessment of Brachial

More information

boso Germany PAOD! The crucial Premium-quality risk marker for heart attack and stroke! Now PAOD screening with the boso ABI-system!

boso Germany PAOD! The crucial Premium-quality risk marker for heart attack and stroke! Now PAOD screening with the boso ABI-system! PAOD! The crucial risk marker for heart attack and stroke! Now PAOD screening with the boso ABI-system! The measurement takes 1 minute and also discovers asymptomatic patients. The new standard for primary

More information

A Healthy Heart. IN BRIEF: Your Guide to

A Healthy Heart. IN BRIEF: Your Guide to IN BRIEF: Your Guide to A Healthy Heart If you re like most people, you may think of heart disease as a problem for other folks. If you re a woman, you may believe that being female protects you from heart

More information

QANS ASSESSMENT SYSTEM

QANS ASSESSMENT SYSTEM Comprehensive Non Invasive System Includes: Autonomic Balance Analysis Cardiovascular Pulse Wave Velocity Analysis ECG Analysis Cardiovascular Fitness Analysis Metabolic Report Arterial Vascular Assessment

More information

Cardiovascular Diseases in CKD

Cardiovascular Diseases in CKD 1 Cardiovascular Diseases in CKD Hung-Chun Chen, MD, PhD. Kaohsiung Medical University Taiwan Society of Nephrology 1 2 High Prevalence of CVD in CKD & ESRD Foley RN et al, AJKD 1998; 32(suppl 3):S112-9

More information

Blood Pressure Estimation Using Photoplethysmography (PPG)

Blood Pressure Estimation Using Photoplethysmography (PPG) Blood Pressure Estimation Using Photoplethysmography (PPG) 1 Siddhi Sham Karande, BE E&TC, VIIT Pune. 2 Kiran Rajendrasingh Thakur, BE E&TC, VIIT Pune. 3 Sneha Dattatraya Waghmare, BE E&TC, VIIT Pune 4

More information

Automated Blood Pressure Monitor

Automated Blood Pressure Monitor Automated Blood Pressure Monitor For Cardiac Stress and Exercise Testing SunTech Tango M2 Our cardiac stress blood pressure (BP) monitoring products give you the confidence to know that patient movement,

More information

Our Vision NADA BoD Strategic Planning Session -

Our Vision NADA BoD Strategic Planning Session - Who we are NADA is a not-for-profit members-led organization established in 1995 as a result of the rising rates of diabetes among First Nations, Inuit and Métis Peoples in Canada Our Vision - 2016 NADA

More information

Utility of Exercise-Induced Zero TBI Sign in Patients on Maintenance Hemodialysis

Utility of Exercise-Induced Zero TBI Sign in Patients on Maintenance Hemodialysis 2016 Annals of Vascular Diseases doi:10.3400/avd.oa.16-00074 Original Article Utility of Exercise-Induced Zero TBI Sign in Patients on Maintenance Hemodialysis Kazuo Tsuyuki, CVT, PhD, 1 Kenji Kohno, PhD,

More information

Clinico-demographic profile of type 2 diabetes patients with cardiac autonomic neuropathy

Clinico-demographic profile of type 2 diabetes patients with cardiac autonomic neuropathy Original Research Article Clinico-demographic profile of type 2 diabetes patients with cardiac autonomic neuropathy Kothai G 1, Prasanna Karthik S 2* 1 Assistant Professor, Department of General Medicine,

More information

Lower Extremity Arterial Disease

Lower Extremity Arterial Disease Lower Extremity Arterial Disease Circulating the Facts About Peripheral Disease Brought to you by the Education Committee of the Society for 1 www.svnnet.org Peripheral Artery Disease (PAD) Many people

More information

Peripheral Arterial Disease

Peripheral Arterial Disease UFS Peripheral Arterial Disease A problem of supply and demand Larry Rhoads, Associate Chief Underwriter November 8, 2011 PAD Two categories of these circulation disorders: Functional peripheral vascular

More information

boso Germany reliably boso Abi-system 100 Premium quality seen in time Arteriosclerosis and economically. PWV measurement option.

boso Germany reliably boso Abi-system 100 Premium quality seen in time Arteriosclerosis and economically. PWV measurement option. A big step in the fight AgAinst heart AttACK AnD stroke: boso Abi-system 100 Arteriosclerosis seen in time reliably and economically. PWV measurement option. Premium quality made in Germany boso Germany

More information

INCREASED PULSE PRESSURE AND SYSTOLIC x HEART RATE DOUBLE PRODUCT AND CARDIOVASCULAR AUTONOMIC NEUROPATHY IN TYPE 2 DIABETIC PATIENTS

INCREASED PULSE PRESSURE AND SYSTOLIC x HEART RATE DOUBLE PRODUCT AND CARDIOVASCULAR AUTONOMIC NEUROPATHY IN TYPE 2 DIABETIC PATIENTS INCREASED PULSE PRESSURE AND SYSTOLIC x HEART RATE DOUBLE PRODUCT AND CARDIOVASCULAR AUTONOMIC NEUROPATHY IN TYPE 2 DIABETIC PATIENTS A.J. Scheen, J.C. Philips, M. Marchand Division of Diabetes, Nutrition

More information

HRV in Diabetes and Other Disorders

HRV in Diabetes and Other Disorders HRV in Diabetes and Other Disorders Roy Freeman, MD Center for Autonomic and Peripheral Nerve Disorders Beth Israel Deaconess Medical Center Harvard Medical School Control Propranolol Atropine Wheeler

More information

Monitoring Equipment. Blood Pressure Monitor Upper Arm Type: Image (Image not to scale)

Monitoring Equipment. Blood Pressure Monitor Upper Arm Type: Image (Image not to scale) Monitoring Equipment Blood Pressure Monitor Upper Arm Type: Order # Description BP500 LCD Size: 40mm x 60mm Blood pressure classification (WHO) indicator; HAD technology (Heart Arrhythmia Detection) Time

More information

Arterial Age and Shift Work

Arterial Age and Shift Work 340 Arterial Age and Shift Work Ioana Mozos 1*, Liliana Filimon 2 1 Department of Functional Sciences, Victor Babes University of Medicine and Pharmacy, Timisoara, Romania 2 Department of Occupational

More information

Peripheral Arterial Disease Extremity

Peripheral Arterial Disease Extremity Peripheral Arterial Disease Lower Extremity 05 Contributor Dr Steven Chong Advisors Dr Ashish Anil Dr Tay Jam Chin Introduction Risk Factors Clinical Presentation Classification History PHYSICAL examination

More information

Copyright 2013 Renua Medical TM, A Health First Technologies, Inc. Company. All rights reserved.

Copyright 2013 Renua Medical TM, A Health First Technologies, Inc. Company. All rights reserved. Copyright 2013 Renua Medical TM, A Health First Technologies, Inc. Company. All rights reserved. This document may not be reproduced in whole, or in part, stored in a retrieval system, or transmitted in

More information

BGmetrix 3000 Series

BGmetrix 3000 Series Product Description BGmetrix 3000 is a suite of FDA cleared bio-sensor medical devices, with adjunct software, that monitors and evaluates several body functions including the autonomic nervous system

More information

Theoretical and practical questions in the evaluation of arterial function Miklós Illyés MD. Ph.D.

Theoretical and practical questions in the evaluation of arterial function Miklós Illyés MD. Ph.D. Theoretical and practical questions in the evaluation of arterial function Miklós Illyés MD. Ph.D. TensioMed Arterial Stiffness Centre, Budapest Heart Institute, Faculty of Medicine, University of Pécs

More information

UC SF. Disclosures. Vascular Assessment of the Diabetic Foot. What are the best predictors of wound healing? None. Non-Invasive Vascular Studies

UC SF. Disclosures. Vascular Assessment of the Diabetic Foot. What are the best predictors of wound healing? None. Non-Invasive Vascular Studies Disclosures Vascular Assessment of the Diabetic Foot What are the best predictors of wound healing? None Shant Vartanian MD Assistant Professor of Vascular Surgery UCSF Vascular Symposium April 20, 2013

More information

Diabetic Foot Ulcers. Alex Khan APRN ACNS-BC MSN CWCN CFCN WCN-C. Advanced Practice Nurse / Adult Clinical Nurse Specialist

Diabetic Foot Ulcers. Alex Khan APRN ACNS-BC MSN CWCN CFCN WCN-C. Advanced Practice Nurse / Adult Clinical Nurse Specialist Diabetic Foot Ulcers Alex Khan APRN ACNS-BC MSN CWCN CFCN WCN-C Advanced Practice Nurse / Adult Clinical Nurse Specialist Organization of Wound Care Nurses www.woundcarenurses.org Objectives Identify Diabetic/Neuropathic

More information

Practical Point in Diabetic Foot Care 3-4 July 2017

Practical Point in Diabetic Foot Care 3-4 July 2017 Diabetic Foot Ulcer : Role of Vascular Surgeon Practical Point in Diabetic Foot Care 3-4 July 2017 Supapong Arworn, MD Division of Vascular and Endovascular Surgery Department of Surgery, Chiang Mai University

More information

Endothelial function is impaired in women who had pre-eclampsia

Endothelial function is impaired in women who had pre-eclampsia Endothelial function is impaired in women who had pre-eclampsia Christian Delles, Catriona E Brown, Joanne Flynn, David M Carty Institute of Cardiovascular and Medical Sciences University of Glasgow United

More information

vasolab 320 Vascular Diagnosis Center

vasolab 320 Vascular Diagnosis Center vasolab 320 Vascular Diagnosis Center Arterial function diagnosis Venous function diagnosis Doppler vl320 EN vasolab 320 modular concept easy to use ergonomic design The vasolab 320 is a modular designed

More information

Non- invasive vascular testing. Pros and Cons of ABIs and Alternative Physiologic Assessments

Non- invasive vascular testing. Pros and Cons of ABIs and Alternative Physiologic Assessments Non- invasive vascular testing Pros and Cons of ABIs and Alternative Physiologic Assessments Non- Invasive Physiologic Arterial Studies Segmental Systolic Pressure Measurements ABIs, TBIs, and full segmentals

More information

boso ABI-system 100 inexpensive New feature: PWV Early detection of PAOD: fast, accurate The easy way of checking for measurement option

boso ABI-system 100 inexpensive New feature: PWV Early detection of PAOD: fast, accurate The easy way of checking for measurement option The easy way of checking for risk of HeART ATTACK AND STROKE: boso ABI-system 100 Early detection of PAOD: fast, accurate inexpensive New feature: PWV measurement option Top quality for doctors and clinics

More information

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors

VITAL SIGNS MONITORING. RVS-100/200 ri-vital. Vital Signs Patient Monitors VITAL SIGNS MONITORING RVS-100/200 ri-vital Vital Signs Patient Monitors RVS-100 ADVANCED VITAL SIGNS MONITOR The RVS-100 is an advanced vital signs monitor which offers pulse oximetry, blood pressure

More information

Due to Perimed s commitment to continuous improvement of our products, all specifications are subject to change without notice.

Due to Perimed s commitment to continuous improvement of our products, all specifications are subject to change without notice. A summary Disclaimer The information contained in this document is intended to provide general information only. It is not intended to be, nor does it constitute, medical advice. Under no circumstances

More information

EDUCATION. Peripheral Artery Disease

EDUCATION. Peripheral Artery Disease EDUCATION Peripheral Artery Disease Peripheral Artery Disease You may have circulation problems that have to do with your blood vessels. You may feel aches, pains, cramps, numbness or muscle fatigue when

More information

Heart Rate and Blood Pressure as Vital Signs

Heart Rate and Blood Pressure as Vital Signs Heart Rate and Blood Pressure as Vital Signs Computer 10 Since the earliest days of medicine heart rate has been recognized as a vital sign an indicator of health, disease, excitement, and stress. Medical

More information

High Risk Podiatry in a Vascular Setting; A new paradigm in Diabetic Foot Disease? Ereena Torpey Senior Podiatrist - FMC

High Risk Podiatry in a Vascular Setting; A new paradigm in Diabetic Foot Disease? Ereena Torpey Senior Podiatrist - FMC High Risk Podiatry in a Vascular Setting; A new paradigm in Diabetic Foot Disease? Ereena Torpey Senior Podiatrist - FMC A new paradigm? Foot ulceration 101 Assessing Perfusion a new challenge Pressure

More information

Measurement of Hemodynamic Parameters: Design of Methods and Hardware

Measurement of Hemodynamic Parameters: Design of Methods and Hardware Measurement of Hemodynamic Parameters: Design of Methods and Hardware Jan Havlík xhavlikj@fel.cvut.cz Lenka Lhotská Dep. of Cybernetics lhotska@fel.cvut.cz Vratislav Fabián Dep. of Physics fabiav1@fel.cvut.cz

More information

Medical Electronics Dr. Neil Townsend Michaelmas Term 2001 ( The story so far.

Medical Electronics Dr. Neil Townsend Michaelmas Term 2001 (  The story so far. Medical Electronics Dr Neil Townsend Michaelmas Term 2001 (wwwrobotsoxacuk/~neil/teaching/lectures/med_elec) Blood Pressure has been measured (in some way) for centuries However, clinical interpretation

More information

iworx Sample Lab Experiment HC-5: Body Position, Exercise, and Cardiac Output

iworx Sample Lab Experiment HC-5: Body Position, Exercise, and Cardiac Output Experiment HC-5: Body Position, Exercise, and Cardiac Output Exercise 1: Cardiac Output While Reclining Aim: To determine the cardiac output of a subject through the measurement of blood pressures and

More information

Coronary artery disease (CAD) risk factors

Coronary artery disease (CAD) risk factors Background Coronary artery disease (CAD) risk factors CAD Risk factors Hypertension Insulin resistance /diabetes Dyslipidemia Smoking /Obesity Male gender/ Old age Atherosclerosis Arterial stiffness precedes

More information

droxidopa (Northera )

droxidopa (Northera ) Applies to all products administered or underwritten by Blue Cross and Blue Shield of Louisiana and its subsidiary, HMO Louisiana, Inc.(collectively referred to as the Company ), unless otherwise provided

More information

Evidence of Baroreflex Activation Therapy s Mechanism of Action

Evidence of Baroreflex Activation Therapy s Mechanism of Action Evidence of Baroreflex Activation Therapy s Mechanism of Action Edoardo Gronda, MD, FESC Heart Failure Research Center IRCCS MultiMedica Cardiovascular Department Sesto S. Giovanni (Milano) Italy Agenda

More information

/tj7-0zq0 510 (k) Summary P

/tj7-0zq0 510 (k) Summary P /tj7-0zq0 510 (k) Summary P Date Prepared: November 28, 2012 Sponsor Information: Pulsecor Limited DEC i 2o12 Level 2, 135 Morrin Road Auckland 1072, New Zealand Sponsor Contact: Andrew Lowe Telephone:

More information

What Is PAD? MAY SHOWERS, BRING SPRING FLOWERS! mhtml:file://c:\users\copper Moon Media\Documents\NMFA\newsletters\2017\May

What Is PAD? MAY SHOWERS, BRING SPRING FLOWERS! mhtml:file://c:\users\copper Moon Media\Documents\NMFA\newsletters\2017\May Page 1 of 5 Subscribe Past Issues Trans What is PAD?, Early Bird Coming Soon! View this email in your browser Forward to a friend What Is PAD? PAD is short for Peripheral Arterial Disease. PAD is caused

More information

MAX PULSE RESULT INTERPRETATION GUIDE PROVE CLINICAL EFFICACY IMPROVE CLINICAL OUTCOMES IMPROVE PATIENT ADHERENCE

MAX PULSE RESULT INTERPRETATION GUIDE PROVE CLINICAL EFFICACY IMPROVE CLINICAL OUTCOMES IMPROVE PATIENT ADHERENCE MAX PULSE RESULT INTERPRETATION GUIDE PROVE CLINICAL EFFICACY IMPROVE CLINICAL OUTCOMES IMPROVE PATIENT ADHERENCE PLETHYSMOGRAPHY VOLUME CAPACITY PG ON FINGERTIP VELOCITY PG (1ST DIFFERENTIATION) APG (2ND

More information

Dopplex ABIlity Automatic Ankle Brachial Index System. Image

Dopplex ABIlity Automatic Ankle Brachial Index System. Image Dopplex ABIlity Automatic Ankle Brachial Index System Image The Problem Cardiovascular Disease (CVD) remains the leading cause of global death and disability and was responsible for the loss of 17 million

More information

DON T LET LEG PAIN BECOME A REAL THREAT.

DON T LET LEG PAIN BECOME A REAL THREAT. DON T LET LEG PAIN BECOME A REAL THREAT. These three words have the power to change lives. Between 8 to 10 million Americans are estimated to suffer from poor blood flow to the legs and feet potentially

More information

AFFORDABLE TECHNOLOGY

AFFORDABLE TECHNOLOGY World Health Organization AFFORDABLE TECHNOLOGY BLOOD PRESSURE MEASURING DEVICES FOR LOW RESOURCE SETTINGS CARDIOVASCULAR DISEASES Blood Pressure Measurement in Low Resource Settings Annex 1: Blood Pressure

More information

BackBeat Cardiac Neuromodulation Therapy (CNT) for Immediate, Substantial and Sustained Lowering of Blood Pressure. Daniel Burkhoff MD PhD

BackBeat Cardiac Neuromodulation Therapy (CNT) for Immediate, Substantial and Sustained Lowering of Blood Pressure. Daniel Burkhoff MD PhD BackBeat Cardiac Neuromodulation Therapy (CNT) for Immediate, Substantial and Sustained Lowering of Blood Pressure Daniel Burkhoff MD PhD Director Heart Failure, Hemodynamics and Mechanical Support Research

More information

ASSESSING THE VASCULAR STATUS OF THE FEET FOR PATIENTS WITH DIABETES

ASSESSING THE VASCULAR STATUS OF THE FEET FOR PATIENTS WITH DIABETES ASSESSING THE VASCULAR STATUS OF THE FEET FOR PATIENTS WITH DIABETES Caroline McIntosh is Senior Lecturer in Podiatry, University of Huddersfield, Yorkshire A reduced blood supply to the lower limb, due

More information

Impedance Cardiography (ICG) Application of ICG for Hypertension Management

Impedance Cardiography (ICG) Application of ICG for Hypertension Management Application of ICG for Hypertension Management 1mA @ 100 khz Impedance Cardiography (ICG) Non-invasive Beat-to-beat Hemodynamic Monitoring Diastole Systole Aortic valve is closed No blood flow in the aorta

More information

Estimation of Pulse Arrival Time Using Impedance Plethysmogram from Body Composition Scales

Estimation of Pulse Arrival Time Using Impedance Plethysmogram from Body Composition Scales Estimation of Pulse Arrival Time Using Impedance Plethysmogram from Body Composition Scales Birutė Paliakaitė 1, Saulius Daukantas 2, Andrius Sakalauskas 2, Vaidotas Marozas 1,2 1 Department of Electronics

More information

The Internist s Approach to Neuropathy

The Internist s Approach to Neuropathy The Internist s Approach to Neuropathy VOLKAN GRANIT, MD, MSC ASSISTANT PROFESSOR OF NEUROLOGY NEUROMUSCU LAR DIVISION UNIVERSITY OF MIAMI, MILLER SCHOOL OF MEDICINE RELEVANT DECLARATIONS Financial disclosures:

More information

Biomedical Instrumentation E. Blood Pressure

Biomedical Instrumentation E. Blood Pressure Biomedical Instrumentation E. Blood Pressure Dr Gari Clifford Adapted from slides by Prof. Lionel Tarassenko Blood pressure Blood is pumped around the body by the heart. It makes its way around the body

More information

Introduction of diverse devices to measure arterial stiffness

Introduction of diverse devices to measure arterial stiffness Slide 1 Introduction of diverse devices to measure arterial stiffness PARK, Jeong Bae, MD, PhD, Medicine/Cardiology, Samsung Cheil Hospital, Sungkyunkwan University School of Medicine 2005 5 27 일혈관연구회부산집담회,

More information

BP-600 Noninvasive Blood Pressure Sensor

BP-600 Noninvasive Blood Pressure Sensor Technical Note BP-600 Overview A person's cardiac output, peripheral vascular resistance, blood pressure, and other cardiovascular parameters change in response to the activities and events taking place

More information

Activity Vital Signs: Heart Rate and Blood Pressure

Activity Vital Signs: Heart Rate and Blood Pressure Activity 8.1.2 Vital Signs: Heart Rate and Blood Pressure Introduction The human body is an amazing machine that automatically monitors and adjusts itself in order to maintain equilibrium or homeostasis.

More information

Keun-Ho Kim and Sang-Suk Lee* Department of Oriental Biomedical Engineering, Sangji University, Wonju , Korea

Keun-Ho Kim and Sang-Suk Lee* Department of Oriental Biomedical Engineering, Sangji University, Wonju , Korea Journal of Magnetics 20(1), 47-51 (2015) ISSN (Print) 1226-1750 ISSN (Online) 2233-6656 http://dx.doi.org/10.4283/jmag.2015.20.1.047 Peripheral Blood Flow Velocity and Peripheral Pulse Wave Velocity Measured

More information

CHAPTER 4 ESTIMATION OF BLOOD PRESSURE USING PULSE TRANSIT TIME

CHAPTER 4 ESTIMATION OF BLOOD PRESSURE USING PULSE TRANSIT TIME 64 CHAPTER 4 ESTIMATION OF BLOOD PRESSURE USING PULSE TRANSIT TIME 4.1 GENERAL This chapter presents the methodologies that are usually adopted for the measurement of blood pressure, heart rate and pulse

More information

Non-invasive examination

Non-invasive examination Non-invasive examination Segmental pressure and Ankle-Brachial Index (ABI) The segmental blood pressure (SBP) examination is a simple, noninvasive method for diagnosing and localizing arterial disease.

More information

Automatic Ankle Brachial Index System. Image

Automatic Ankle Brachial Index System. Image Automatic Ankle Brachial Index System Image The Problem Cardiovascular Disease (CVD) remains the leading cause of global death and disability and was responsible for the loss of 17 million lives in 2008.

More information

Sympathetic Vasomotor Response Of The Radial Artery In Patients With End Stage Renal Disease

Sympathetic Vasomotor Response Of The Radial Artery In Patients With End Stage Renal Disease ISPUB.COM The Internet Journal of Nephrology Volume 2 Number 1 Sympathetic Vasomotor Response Of The Radial Artery In Patients With End Stage Renal Disease L Galea, M Schembri, M Debono Citation L Galea,

More information

TODAY S TOPIC Blood Pressure & Pulse Wave Measurement Combined in One Procedure Re-classification of Risk Patients

TODAY S TOPIC Blood Pressure & Pulse Wave Measurement Combined in One Procedure Re-classification of Risk Patients CARDIOVASCULAR TECHNOLOGY AND INDICATION SERVICE TODAY S TOPIC Blood Pressure & Pulse Wave Measurement Combined in One Procedure Re-classification of Risk Patients SERIES Hypertension Management in the

More information

8) BLOOD PRESSURE AND PULSE RATE RESPONSES TO SUSTAINED HANDGRIP DYNAMOMETER TEST IN RHEUMATOID ARTHRITIS PATENTS

8) BLOOD PRESSURE AND PULSE RATE RESPONSES TO SUSTAINED HANDGRIP DYNAMOMETER TEST IN RHEUMATOID ARTHRITIS PATENTS 8) BLOOD PRESSURE AND PULSE RATE RESPONSES TO SUSTAINED HANDGRIP DYNAMOMETER TEST IN RHEUMATOID ARTHRITIS PATENTS Dr. RANGRAO M. BHISE*, Dr. A.D.HATEKAR**, Dr. (Mrs.) S.D.KAUNDINYA*** *Corresponding author:

More information

Device Equivalence Evaluation Form

Device Equivalence Evaluation Form Device Equivalence Evaluation Form Comparison of the HARTMANN Veroval upper arm blood pressure monitor with the AViTA BPM63S Devices Pictures HARTMANN Veroval upper arm blood pressure monitor AViTA BPM63S

More information

Objective assessment of CLI patients Hemodynamic parameters

Objective assessment of CLI patients Hemodynamic parameters Objective assessment of CLI patients Hemodynamic parameters Worth anything in end stage patients? Marianne Brodmann Angiology, Medical University Graz, Austria Disclosure Speaker name: Marianne Brodmann

More information

AUTONOMIC FUNCTION IS A HIGH PRIORITY

AUTONOMIC FUNCTION IS A HIGH PRIORITY AUTONOMIC FUNCTION IS A HIGH PRIORITY 1 Bladder-Bowel-AD Tetraplegia Sexual function Walking Bladder-Bowel-AD Paraplegia Sexual function Walking 0 10 20 30 40 50 Percentage of respondents an ailment not

More information

Special Lecture 10/28/2012

Special Lecture 10/28/2012 Special Lecture 10/28/2012 HYPERTENSION Dr. HN Mayrovitz Special Lecture 10/28/2012 Arterial Blood Pressure (ABP) - Definitions ABP Review Indirect Oscillographic Method Resistance (R), Compliance (C)

More information

Blood Pressure 1 of 22 Boardworks Ltd 2011

Blood Pressure 1 of 22 Boardworks Ltd 2011 Blood Pressure 1 of 22 Boardworks Ltd 2011 2 of 22 Boardworks Ltd 2011 Heart rate 3 of 22 Boardworks Ltd 2011 Heart rate is the rate at which your heart beats. It can be measured by taking a pulse. A pulse

More information

Q&A. DEMO Version

Q&A. DEMO Version ACSM Exercise Specialist Exam Q&A DEMO Version Copyright (c) 2010 Chinatag LLC. All rights reserved. Important Note Please Read Carefully For demonstration purpose only, this free version Chinatag study

More information

RM- 3A Full Report Review How to Use the 8 Risk Factors

RM- 3A Full Report Review How to Use the 8 Risk Factors RM- 3A Full Report Review How to Use the 8 Risk Factors RM- 3A Cardiovascular and ANS Medical Device The RM- 3A medical device is a powerful analytic tool in managing your patients health. Scientifically

More information

RM-3A Clinical Diagnosis Reference Guide RM-3A Cardiovascular and ANS Medical Device

RM-3A Clinical Diagnosis Reference Guide RM-3A Cardiovascular and ANS Medical Device RM-3A Clinical Diagnosis Reference Guide RM-3A Cardiovascular and ANS Medical Device The RM-3A medical device is a powerful analytical tool in managing your patients health. Scientifically validated and

More information

Clinical Study Of Autonomic Neuropathy In Diabetes Mellitus

Clinical Study Of Autonomic Neuropathy In Diabetes Mellitus IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 17, Issue 3 Ver.19 March. (2018), PP 23-27 www.iosrjournals.org Clinical Study Of Autonomic Neuropathy

More information

Arterial stiffness index: A new evaluation for arterial stiffness in elderly patients with essential hypertension

Arterial stiffness index: A new evaluation for arterial stiffness in elderly patients with essential hypertension Blackwell Science, LtdOxford, UK GGIGeriatrics and Gerontology International1444-15862002 Blackwell Science Asia Pty Ltd 24December 2002 045 ASI in elderly hypertensive patients M Kaibe et al. 10.1046/j.1444-1586.2002.00045.x

More information

boso ABI-system 100 Early detection of PAOD fast, precise, without Doppler Premium quality for doctors and hospitals

boso ABI-system 100 Early detection of PAOD fast, precise, without Doppler Premium quality for doctors and hospitals boso ABI-system 100 Early detection of PAOD fast, precise, without Doppler Premium quality for doctors and hospitals Product of tradition Premium quality for doctors and hospitals For decades, boso has

More information

LAB 4. Human Cardiovascular Lab

LAB 4. Human Cardiovascular Lab 35 Assignments: LAB 4 Human Cardiovascular Lab Due before lab: Do IP exercises (Factors that Affect Blood Pressure and Arterial Baroreceptor Reflex (Pgs. 46-47). Quiz: Define the terms on pg 36 and IP

More information

Case Study: Chris Arden. Peripheral Arterial Disease

Case Study: Chris Arden. Peripheral Arterial Disease Case Study: Chris Arden Peripheral Arterial Disease Patient Presentation Diane is a 65-year-old retired school teacher She complains of left calf pain when walking 50 metres; the pain goes away after she

More information

Departments of Cardiology and Vascular Surgery Michaelidion Cardiac Center University of Ioannina, Greece

Departments of Cardiology and Vascular Surgery Michaelidion Cardiac Center University of Ioannina, Greece Departments of Cardiology and Vascular Surgery Michaelidion Cardiac Center University of Ioannina, Greece ARGYRIS Vassilis, PEROULIS Michalis, MATSAGKAS Miltiadis, BECHLIOULIS Aris, MICHALIS Lampros, NAKA

More information

POSTURAL ORTHOSTATIC TACHYCARDIA SYNDROME (POTS) IT S NOT THAT SIMPLE

POSTURAL ORTHOSTATIC TACHYCARDIA SYNDROME (POTS) IT S NOT THAT SIMPLE POSTURAL ORTHOSTATIC TACHYCARDIA SYNDROME (POTS) IT S NOT THAT SIMPLE POTS Irritable heart syndrome. Soldier s heart. Effort syndrome. Vasoregulatory asthenia. Neurocirculatory asthenia. Anxiety neurosis.

More information

MEDICALSOFT. Innovative health & wellness screening systems for professional and personal use

MEDICALSOFT. Innovative health & wellness screening systems for professional and personal use MEDICALSOFT Innovative health & wellness screening systems for professional and personal use About us The MEDICALSOFT Company is a manufacturer of a range of innovative equipment based on cuttingedge diagnostic

More information

Aortic and Iliac Artery Occlusive Disease (Updated 10.08)

Aortic and Iliac Artery Occlusive Disease (Updated 10.08) S PATIENT INFORMATION oregon surgical specialists Aortic and Iliac Artery Occlusive Disease (Updated 10.08) Abdominal aortic and iliac artery occlusive disease occurs when the arteries in your abdomen

More information

Abstract. (Left Mouse-click to begin and move to next slide.)

Abstract. (Left Mouse-click to begin and move to next slide.) Abstract (Left Mouse-click to begin and move to next slide.) A Comparison of Pulse Pressure, Arterial Stiffness, and Endothelial Function for the Diagnosis and Prognostic Risk of Coronary Heart Disease

More information

Clinical application of Arterial stiffness. pulse wave analysis pulse wave velocity

Clinical application of Arterial stiffness. pulse wave analysis pulse wave velocity Clinical application of Arterial stiffness pulse wave analysis pulse wave velocity Arterial system 1. Large arteries: elastic arteries Aorta, carotid, iliac, Buffering reserve: store blood during systole

More information

Assessment of Arterials Functions: Is Pulse Wave Velocity ready forprime Time. Gérard M. LONDON INSERM U970 Hopital Georges Pompidou Paris, France

Assessment of Arterials Functions: Is Pulse Wave Velocity ready forprime Time. Gérard M. LONDON INSERM U970 Hopital Georges Pompidou Paris, France Assessment of Arterials Functions: Is Pulse Wave Velocity ready forprime Time Gérard M. LONDON INSERM U970 Hopital Georges Pompidou Paris, France The causes of Cardiovascular Diseases in CKD Systolic BP;

More information

EARLY IDENTIFICATION AND FOLLOW-UP OF PERIPHERAL AUTONOMIC NEUROPATHIES

EARLY IDENTIFICATION AND FOLLOW-UP OF PERIPHERAL AUTONOMIC NEUROPATHIES EARLY IDENTIFICATION AND FOLLOW-UP OF PERIPHERAL AUTONOMIC NEUROPATHIES llestablish diagnosis llcontrol effectiveness of treatment llprovide quantitative data to adapt patient care and lifestyle 3 MINUTES

More information

Anatomy, Biomechanics, Work Physiology, and Anthropometry. After completing and understanding of the current chapter students should be able to:

Anatomy, Biomechanics, Work Physiology, and Anthropometry. After completing and understanding of the current chapter students should be able to: Chapter 2 Anatomy, Biomechanics, Work Physiology, and Anthropometry Learning outcomes: After completing and understanding of the current chapter students should be able to: Describe the anatomical structure

More information

CAMOSUN COLLEGE BIOLOGY 144 (2010) LABS

CAMOSUN COLLEGE BIOLOGY 144 (2010) LABS LAB 8: CARDIOVASCULAR PHYSIOLOGY PART 1. HEART SOUNDS AND PULSE DETERMINATIONS Introduction Two distinct sounds can be heard during each cardiac cycle. These sounds are commonly described as lub and dup