Welcome to the 8 th European Bifurcation Club October Barcelona

Size: px
Start display at page:

Download "Welcome to the 8 th European Bifurcation Club October Barcelona"

Transcription

1 Welcome to the 8 th European Bifurcation Club October Barcelona Safety and clinical efficacy of Sideguard stent for treatment of bifurcation lesions Interim results from European multicentre Sideguard Bifurcation Registry study

2 Dr. Sanjay Sastry Manchester Heart Centre Royal Bolton Hospital Royal Albert Edward Infirmary, Wigan

3 Trumpet Sideguard : Self Expanding Nitinol for Bifurcations Gimbal Anchor Trumpet Gimbal Anchor Flared end with 3 markers Easy crossing Ostial coverage Higher radial force Transition zone Axial flexibility Lower radial force. Spacer to improve anchoring. Distal markers

4 Sideguard Profile Sideguard Self-expanding Nitinol Stent Delivers like a PCI catheter Rx, low-profile (<3.2Fr), single wire, employs standard inflators Sheath prevents migration & allows accurate placement Split Sheath Technology

5 The Sideguard Coronary Sidebranch Registry A post market registry to observe the clinical outcomes of the Bare Metal Sideguard Coronary Sidebranch stent in de novo Bifurcation Lesions of Native Coronary Arteries

6 European Registry Summary Total Registry Patients Enrolled 419 Enrolment is on-going in Germany, Italy and the UK

7 European Registry Demographics Medical history of patients N= 419 Age profile 65 years (35 92) Male 77% Smokers/previous smokers 61% Diabetes 20% Family history of CV disease 49% Previous MI 33% Previous CABG 4% Previous PCI 32% Stroke/TIA 6% Hypertension 71% Hypercholesterolemia 63% Congestive Heart Failure 5%

8 85 Sites with 5+ enrolment

9 Lesion Morphology

10 Lesion Morphology

11 Procedural Details Item Average (n=419) Procedure time Contrast Volume Fluoroscopy time 78 minutes (Min: 20; Max:305) 252ml (Min:62ml; Max:1250ml) 20min47sec (Min:1.50; Max:140.40) Kissing Balloon 51%

12 Procedural Details Baseline Vessel & lesion characteristics (n=419) Mainbranch Sidebranch Mean Vessel Diameter Mean Vessel Diameter 3.25mm +/ mm +/ Mean Lesion Length Mean Lesion Length 20.55mm +/ mm +/ Mean Stent Length Mean Stent Length 22.54mm +/ mm +/ nd Stent (%, L+/-σ) 3rd Stent (%, L+/-σ) Second Stent used 30%, 17.73mm +/ %, 17.47mm +/ % Calcification present 31.5% Tortuous anatomy 24.9%

13 Device / Procedural Success details Device failures 11 Stent not deployed at intended site 8 Did not cross proximal lesion 2 SB occlusion caused when deploying MV stent 1 Lesion failures 27 Sidebranch lesion failures (DS 50+%) 7 Main vessel lesion failures (DS 50+%) 1 Both vessel lesion failures (DS 50+%) 2 Procedural failures 4 Myocardial infarction 2 Repeat revascularisation (1MB & 1SB) 2

14 European Registry Primary Endpoint MACE at 30 days MI 10/ % SB TLR MV TLR 3/399 1/ % 0.25% Death 1/ % Total 15/ % MACE at 12 Months MI 6/ % SB TLR MV TLR Both 5/205 3/205 5/ % 1.5% 2.4% Death 2/205 1% Total 21/ % MACE at 6 Months MI 12/ % SB TLR MV TLR Both 6/322 2/322 2/ % 0.6% 0.6 Death 1/ % Total 23/ % Stent Thrombosis Sub-acute (<30d) 5 1.2% Late (>30d, <1year) 1 0.3% Very late (> 1year) 0 0% Total 6/ %

15 Provisional Technique Comparison Questioning the Keep it Simple approach Published studies promote the keep it simple approach to bifurcation stenting strategies. We compare their results to the Sideguard data CACTUS (2009) BBC ONE (2010) DK Crush II (2011) Simple (n=173) Crush (n=177) Simple (n=250) Complex (n=250) Provisional (n=185) DK Crush (n=185) MACE 15.0 (6m) 15.8 (6m) 8.0 (9m) 15.2 (9m) 17.3 (12m) 10.3 (12m) CE Trial (n=83) 10.8 (6m) Sideguard Registry (n=310) 7.1 (6m) No penalty for using a dedicated second stent. CE Trial (n=83) 12.0 (12m) Sideguard Registry (n=189) 10.2 (12m)

16 Conclusion The Sideguard device offers a straight-forward bifurcation solution that provides full coverage at the ostium of the sidebranch while maintaining wire access to the main vessel at all times. Excellent safety profile obtained from the European Registry with MACE rates at 6 months of 7.1% with a sidebranch failure rate of 2.5% and a bifurcation failure rate of 3.1% Data continues to substantiate the view that there is no procedural or long-term penalty for placing a stent in the sidebranch while offering confidence by preserving and protecting the sidebranch due to plaque and carina shift.

17 THANK YOU

18 Sideguard Case example Positive re-modelling: IVUS sub study Post-Intervention Stent area=4.4 mm 2 Lumen area=4.4 mm 2 Follow-up Stent area=5.7 mm 2 Lumen area=5.7 mm 2 Main Vessel *IH area=0.0 mm 2 IVUS images Gary S. Mintz M.D. Cardiovascular Research Foundation, New York, NY,USA

19 Nitinol Overview

LM stenting - Cypher

LM stenting - Cypher LM stenting - Cypher Left main stenting with BMS Since 1995 Issues in BMS era AMC Restenosis and TLR (%) 3 27 TLR P=.282 Restenosis P=.71 28 2 1 15 12 Ostium 5 4 Shaft Bifurcation Left main stenting with

More information

Protection of side branch is essential in treating bifurcation lesions: overview

Protection of side branch is essential in treating bifurcation lesions: overview Angioplasty Summit TCT Asia Pacific Seoul, April 26-28, 2006 Protection of side branch is essential in treating bifurcation lesions: overview Alfredo R Galassi, MD, FACC, FSCAI, FESC Head of the Catetherization

More information

Complex Coronary Interventions: Bifurcations. John M. Lasala MD PhD Professor of Medicine Washington University St Louis, Missouri

Complex Coronary Interventions: Bifurcations. John M. Lasala MD PhD Professor of Medicine Washington University St Louis, Missouri Complex Coronary Interventions: Bifurcations John M. Lasala MD PhD Professor of Medicine Washington University St Louis, Missouri Disclosures Advisory Board Boston Scientific, St. Jude Medical Speaker-

More information

Eulogio Garcia MD H. U. Gregorio Marañon Madrid

Eulogio Garcia MD H. U. Gregorio Marañon Madrid Eulogio Garcia MD H. U. Gregorio Marañon Madrid Coronary Bifurcation Lesions Open Issues Technically demanding Time consuming Low tech success rate Too much operator dependant Off-the the-shelf standard

More information

ΣΥΜΠΛΟΚΕΣ ΑΓΓΕΙΟΠΛΑΣΤΙΚΕΣ ΑΓΓΕΙΟΠΛΑΣΤΙΚΗ ΔΙΧΑΣΜΩΝ

ΣΥΜΠΛΟΚΕΣ ΑΓΓΕΙΟΠΛΑΣΤΙΚΕΣ ΑΓΓΕΙΟΠΛΑΣΤΙΚΗ ΔΙΧΑΣΜΩΝ ΣΥΜΠΛΟΚΕΣ ΑΓΓΕΙΟΠΛΑΣΤΙΚΕΣ ΑΓΓΕΙΟΠΛΑΣΤΙΚΗ ΔΙΧΑΣΜΩΝ DR ΝΙΚΟΛΑΟΣ ΚΑΥΚΑΣ MD, FESC Διευθυντής, Υπεύθυνος Αιμοδ/κού Εργαστηρίου Καρδιολογική Κλινική Γεν. Νοσοκομείο ΚΑΤ-ΕΚΑ PCI in Coronary Bifurcations Bifurcations

More information

Drug Eluting Stents: Bifurcation and Left Main Approach

Drug Eluting Stents: Bifurcation and Left Main Approach TCT Asia 2006 Drug Eluting Stents: Bifurcation and Left Main Approach Eberhard Grube MD FACC, FSCAI Heart Center,, Germany Stanford University, School of Medicine, CA, USA DES in High Risk Lesions TAXUS

More information

I have nothing to disclose.

I have nothing to disclose. I have nothing to disclose. ESC congress of cardiology, 25-29th August 2012, Munich, Germany Minsk-Village 6, August 26 th, 2:22 PM Session: The grey zone of coronary interventions: The real bifurcation

More information

A Paclitaxel-Eluting Balloon for Bifurcation Lesions : Early Clinical Observations

A Paclitaxel-Eluting Balloon for Bifurcation Lesions : Early Clinical Observations Innovative Devices : Non Stent Technologies : Drug Eluting Balloons A Paclitaxel-Eluting Balloon for Bifurcation Lesions : Early Clinical Observations Pieter R. Stella, MD Director CardioVascular Research

More information

EBC London 2013 Provisional SB stenting strategy with kissing balloon with Absorb

EBC London 2013 Provisional SB stenting strategy with kissing balloon with Absorb EBC London 2013 Provisional SB stenting strategy with kissing balloon with Absorb A. Medina Servicio de Cardiología Hospital Universitario de Gran Canaria Dr. Negrín Islas Canarias (Spain) Provisional

More information

Bifurcation stenting with BVS

Bifurcation stenting with BVS Bifurcation stenting with BVS Breaking the limits or just breaking the struts? Maciej Lesiak Department of Cardiology University Hospital in Poznan, Poland Disclosure Speaker s name: Maciej Lesiak I have

More information

Side Branch Occlusion

Side Branch Occlusion Side Branch Occlusion Mechanism, Outcome, and How to avoid it From COBIS II Registry Hyeon-Cheol Gwon Cardiac&Vascular Center, Samsung Medical Center Sungkyunkwan University School of Medicine SB occlusion

More information

The Spectrum of Dedicated Stents for Bifurcation Lesions: Current Status and Future Projections. Martin B. Leon, MD

The Spectrum of Dedicated Stents for Bifurcation Lesions: Current Status and Future Projections. Martin B. Leon, MD The Spectrum of Dedicated Stents for Bifurcation Lesions: Current Status and Future Projections Martin B. Leon, MD Columbia University Medical Center Cardiovascular Research Foundation New York City Angioplasty

More information

DK Crush,Culotte,SKS,T or TAP. Subhash Chandra, MD,DM,FACC Chairman,Cardiac Sciences BLK Super Speciality Hospital, Pusa Road, New Delhi

DK Crush,Culotte,SKS,T or TAP. Subhash Chandra, MD,DM,FACC Chairman,Cardiac Sciences BLK Super Speciality Hospital, Pusa Road, New Delhi PCI for Bifurcations: Which is the best strategy DK Crush,Culotte,SKS,T or TAP Subhash Chandra, MD,DM,FACC Chairman,Cardiac Sciences BLK Super Speciality Hospital, Pusa Road, New Delhi CSI 2018 Selection

More information

Non-LM bifurcation studies of importance in 2011

Non-LM bifurcation studies of importance in 2011 7th European Bifurcation Club 14-15 October 2011 LISBON Goran Stankovic MD, PhD Non-LM bifurcation studies of importance in 2011 October 15 th : 08:00 08:10 DKCRUSH-II: A Prospective Randomized Trial of

More information

STENTYS for Le, Main Sten2ng. Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy

STENTYS for Le, Main Sten2ng. Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy STENTYS for Le, Main Sten2ng Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy Disclosure Statement of Financial Interest I, Carlo Briguori DO NOT have a financial interest/ arrangement or affilia2on

More information

Are Asian Patients Different? - Updates Of Biomatrix Experience In Regional Settings: BEACON II (3 Yr F up) &

Are Asian Patients Different? - Updates Of Biomatrix Experience In Regional Settings: BEACON II (3 Yr F up) & Are Asian Patients Different? - Updates Of Biomatrix Experience In Regional Settings: BEACON II (3 Yr F up) & Biomatrix TM Single Center Experience (Indonesia)(Final 5 Yr F up) T. Santoso University of

More information

Le# main treatment with Stentys stent. Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy

Le# main treatment with Stentys stent. Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy Le# main treatment with Stentys stent Carlo Briguori, MD, PhD Clinica Mediterranea Naples, Italy Disclosure Statement of Financial Interest I, Carlo Briguori DO NOT have a financial interest/ arrangement

More information

Insight from the CACTUS trial Coronary Bifurcation Application of the Crush

Insight from the CACTUS trial Coronary Bifurcation Application of the Crush EBC - Prague 26-28 september 2008 Insight from the CACTUS trial The role of final kissing balloon inflation F. Airoldi,, A. Colombo San Raffaele Scientific Institute EMO Centro Cuore,, Columbus Hospital

More information

Y. Louvard, ICPS, Massy, France. TCT Asia Pacific 2010

Y. Louvard, ICPS, Massy, France. TCT Asia Pacific 2010 Provisional Bifurcation Stenting: Main Branch First Y. Louvard, ICPS, Massy, France TCT Asia Pacific 2010 No conflict of interest to declare M Main prox. first A Main Accross side first D Distal first

More information

FFR-guided Jailed Side Branch Intervention

FFR-guided Jailed Side Branch Intervention FFR-guided Jailed Side Branch Intervention - Pressure wire in Bifurcation lesions - Bon-Kwon Koo, MD, PhD Seoul National University Hospital, Seoul, Korea Bifurcation Lesions Bifurcation Lesions Still

More information

Sideguard dedicated stent system for the treatment of coronary bifurcation artery lesions

Sideguard dedicated stent system for the treatment of coronary bifurcation artery lesions Device device Evaluation evaluation Sideguard dedicated stent for the treatment of coronary bifurcation artery lesions Coronary artery bifurcation disease is considered to be technically challenging since

More information

FLEXIBLE, BALOON EXPANDABLE

FLEXIBLE, BALOON EXPANDABLE EARLY RESULTS OF A CLINICAL TRIAL OF FLEXIBLE, BALOON EXPANDABLE COVERED STENT GRAFT IN ILIAC OCCLUSIVE DISEASE Chris LeCroy Coastal Vascular and Interventional Pensacola, Florida Clinical Trial WL GORE

More information

PCI for Bifurcation Coronary Lesion

PCI for Bifurcation Coronary Lesion PCI for Bifurcation Coronary Lesion Bifurcation Lesions PCI is Challenging Higher acute complication Lower success rates Higher restenosis & TLR Restenosis Rate 21 ~ 57% TLR 8 ~ 43% Event Free Survival

More information

Contemporary therapy of bifurcation lesions

Contemporary therapy of bifurcation lesions Contemporary therapy of bifurcation lesions Dr Angela Hoye MB ChB PhD MRCP Interventional Cardiologist Kingston-upon-Hull, UK Hull The challenge of bifurcations Risk of peri-procedural infarction Relatively

More information

Insight from Nordic III

Insight from Nordic III Insight from Nordic III Fifth European Bifurcation Club Meeting Berlin 16-17 October 2009 Jens Flensted Lassen, MD, PH.D., FESC. Department of Cardiology Skejby Hospital, University of Aarhus Denmark Nordic-Baltic

More information

Consensus so far and what we will be focusiong on this time

Consensus so far and what we will be focusiong on this time Consensus so far and what we will be focusiong on this time The 6 th European Bifurcation Club Meeting Budapest October 22-23 2010 Jens Flensted Lassen, MD, PH.D., FESC. Department of Cardiology B Skejby

More information

Drug eluting balloons in CAD

Drug eluting balloons in CAD Drug eluting balloons in CAD Ioannis Iakovou, MD, PhD Interventional Cardiology 1 st Cath Lab Onassis Cardiac Surgery Center Drug-Eluting Balloons (DEB) Technology and Applications 1. Special Features

More information

The tailored solution for your bifurcation therapy

The tailored solution for your bifurcation therapy The tailored solution for your bifurcation therapy The tailored solution for your bifurcation therapy Dedicated self-expanding platform that conforms to the specific bifurcation anatomy Full bifurcation

More information

POLish Bifurcation Optimal treatment Strategy randomized Study (POLBOSS) - Interim analysis

POLish Bifurcation Optimal treatment Strategy randomized Study (POLBOSS) - Interim analysis POLish Bifurcation Optimal treatment Strategy randomized Study (POLBOSS) - Interim analysis Robert J. Gil 1,2, MD, PhD, FESC 1- Mossakowski Medical Research Centre, Polish Academy of Sciences 2- Invasive

More information

The Tryton Side Branch System in Distal Left Main PCI

The Tryton Side Branch System in Distal Left Main PCI The Tryton Side Branch System in Distal Left Main PCI Yaron Almagor, MD Director, Interventional Cardiology Shaare Zedek Medical Center Jerusalem, Israel TCTAP Seoul April 2013 Speaker s name: YARON ALMAGOR

More information

Effect of Intravascular Ultrasound- Guided vs. Angiography-Guided Everolimus-Eluting Stent Implantation: the IVUS-XPL Randomized Clinical Trial

Effect of Intravascular Ultrasound- Guided vs. Angiography-Guided Everolimus-Eluting Stent Implantation: the IVUS-XPL Randomized Clinical Trial Effect of Intravascular Ultrasound- Guided vs. Angiography-Guided Everolimus-Eluting Stent Implantation: the IVUS-XPL Randomized Clinical Trial Myeong-Ki Hong, MD. PhD on behalf of the IVUS-XPL trial investigators

More information

ANGIOPLASY SUMMIT 2007 TCT ASIA PACIFIC. Seoul, Korea: April Session: Left mains & bifurcation intervention

ANGIOPLASY SUMMIT 2007 TCT ASIA PACIFIC. Seoul, Korea: April Session: Left mains & bifurcation intervention ANGIOPLASY SUMMIT 2007 TCT ASIA PACIFIC Seoul, Korea: 25-27 27 April 2007 Session: Left mains & bifurcation intervention An integrated approach to bifurcation lesions: lessons from years of randomized

More information

New Double Stent Technique

New Double Stent Technique New Double Stent Technique Jasvindar Singh MD, FACC Associate Professor of Medicine Barnes-Jewish Hospital/Washington University in St. Louis jzsingh@dom.wustl.edu New Double Stent Technique Jasvindar

More information

Percutaneous Intervention of Unprotected Left Main Disease

Percutaneous Intervention of Unprotected Left Main Disease Percutaneous Intervention of Unprotected Left Main Disease Technical feasibility and Clinical outcomes Seung-Jung Park, MD, PhD, FACC Professor of Internal Medicine Asan Medical Center, Seoul, Korea Unprotected

More information

6 th European Bifurcation Club October BUDAPEST. Kissing in simple strategy? Why and how I kiss. Y. Louvard, ICPS, Massy France

6 th European Bifurcation Club October BUDAPEST. Kissing in simple strategy? Why and how I kiss. Y. Louvard, ICPS, Massy France 6 th European Bifurcation Club 22-23 October 2010 - BUDAPEST Kissing in simple strategy? Why and how I kiss Y. Louvard, ICPS, Massy France A long experience of kissing 1996 Patients 79 Final Kissing balloon

More information

Mid-term results from real-world REPARA registry. Felipe Hernandez, on behalf of the REPARA investigators

Mid-term results from real-world REPARA registry. Felipe Hernandez, on behalf of the REPARA investigators Mid-term results from real-world REPARA registry Felipe Hernandez, on behalf of the REPARA investigators Potential conflicts of interest Speaker's name: Felipe Hernandez I have the following potential

More information

Dr. Robert J. van Geuns. Thoraxcenter ErasmusMC Rotterdam On behalf of Dr. Jean Fajadet and Co-investigators

Dr. Robert J. van Geuns. Thoraxcenter ErasmusMC Rotterdam On behalf of Dr. Jean Fajadet and Co-investigators Complex coronary bifurcation lesions treated with the novel polymer-free dedicated bifurcation paclitaxel-eluting stent (Nile pax): clinical and angiographic results of the prospective, multicenter bipax

More information

PrOspective multicenter study of carotid artery stenting Usinng mer Stent OCEANUS study!!!

PrOspective multicenter study of carotid artery stenting Usinng mer Stent OCEANUS study!!! PrOspective multicenter study of carotid artery stenting Usinng mer Stent OCEANUS study!!! Prof Piotr Pieniazek MD PhD Jagiellonian University Institute of Cardiology, John Paul II Hospital Krakow, Poland

More information

Unprotected LM intervention

Unprotected LM intervention Unprotected LM intervention Guideline for COMBAT Seung-Jung Park, MD, PhD Professor of Internal Medicine, Seoul, Korea Current Recommendation for unprotected LMCA Stenosis Class IIb C in ESC guideline

More information

Resolute in Bifurcation Lesions: Data from the RESOLUTE Clinical Program

Resolute in Bifurcation Lesions: Data from the RESOLUTE Clinical Program Resolute in Bifurcation Lesions: Data from the RESOLUTE Clinical Program Prof. Ran Kornowski, MD, FESC, FACC Director - Division of Interventional Cardiology Rabin Medical Center and Tel Aviv University,

More information

Management of Non-protected Left-Main Bifurcation without Drug Eluting Stent. Masahiko Ochiai MD, FACC, FESC, FSCAI

Management of Non-protected Left-Main Bifurcation without Drug Eluting Stent. Masahiko Ochiai MD, FACC, FESC, FSCAI Management of Non-protected Left-Main Bifurcation without Drug Eluting Stent Masahiko Ochiai MD, FACC, FESC, FSCAI Division of Cardiology and Cardiovascular Surgery Showa University Northern Yokohama Hospital

More information

Final Kissing Ballooning Returns? The analysis of COBIS II registry

Final Kissing Ballooning Returns? The analysis of COBIS II registry Final Kissing Ballooning Returns? The analysis of COBIS II registry Hyeon- Cheol Gwon Heart Vascular & Stroke Ins?tute, Samsung Medical Center Sungkyunkwan University School of Medicine Final Kissing Ballooning

More information

Tailored bifurcation therapy

Tailored bifurcation therapy Tailored bifurcation therapy Dedicated self-expanding platform that conforms to the specific bifurcation anatomy Full bifurcation lesion coverage without creating a false carina Bifurcation DES technology

More information

Technical considerations in the Treatment of Left Main Lesions Ioannis Iakovou, MD, PhD

Technical considerations in the Treatment of Left Main Lesions Ioannis Iakovou, MD, PhD Technical considerations in the Treatment of Left Main Lesions Ioannis Iakovou, MD, PhD Onassis Cardiac Surgery Center, Athens, Greece Critical issues in LM PCI Anatomic variability Techniques Variability

More information

Side branch occlusion in 500 ABSORB BVS

Side branch occlusion in 500 ABSORB BVS Side branch occlusion in 500 ABSORB BVS Clinical implications and Solutions Robert-Jan van Geuns, MD, PhD Associate Professor,Thoraxcenter, Erasmus Medical Center, Rotterdam, the Netherlands On behalf

More information

Complex PCI of an LAD/Diagonal bifurcation lesion (Medina 1,1,1) utilizing the DK Crush technique ".

Complex PCI of an LAD/Diagonal bifurcation lesion (Medina 1,1,1) utilizing the DK Crush technique . Complex PCI of an LAD/Diagonal bifurcation lesion (Medina 1,1,1) utilizing the DK Crush technique ". "Σύμπλοκη αγγειοπλαστική βλάβης διχασμού LAD/Diagonal (Medina 1,1,1) με την τεχνική DK crush ". Anastasios

More information

Bifurcations Bad Krozingen I

Bifurcations Bad Krozingen I Bifurcations Bad Krozingen I Clinical outcome 5 years after routine T-Stenting versus provisional T-stenting in the treatment of de novo coronary bifurcation lesions using sirolimus-eluting stents M. Ferenc

More information

Bifurcation Stenting: IVUS and OCT Information

Bifurcation Stenting: IVUS and OCT Information Bifurcation Stenting: IVUS and OCT Information Yoshinobu Murasato MD, PhD (New Yukuhashi Hospital) On behalf of J-REVERSE investigators October 14-15, 2011, Lisbon Proximal stent deformation induced by

More information

Why I try to avoid side branch dilatation

Why I try to avoid side branch dilatation Why I try to avoid side branch dilatation Hyeon-Cheol Gwon Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea Why I don t kiss? I kiss! I prefer to discuss SB ballooning rather

More information

Update from the Tryton IDE study

Update from the Tryton IDE study Update from the Tryton IDE study Maciej Lesiak EBC 2015 - Athens The Tryton Bifurcation Trial: A randomized comparison of a provisional one-stent vs. a dedicated two-stent strategy for true bifurcation

More information

DESolve NX Trial Clinical and Imaging Results

DESolve NX Trial Clinical and Imaging Results DESolve NX Trial Clinical and Imaging Results Alexandre Abizaid, MD, PhD, Instituto Dante Pazzanese, Sao Paulo, Brazil On behalf of the DESolve Nx Trial Investigators Please refer to the TCT2014 App or

More information

Integrated Use of IVUS and FFR for LM Stenting

Integrated Use of IVUS and FFR for LM Stenting Integrated Use of IVUS and FFR for LM Stenting Gary S. Mintz, MD Cardiovascular Research Foundation Four studies have highlighted the inaccuracy of angiography in the assessment of LMCA disease Fisher

More information

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ

History of the Powerlink System Design and Clinical Results. Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ History of the Powerlink System Design and Clinical Results Edward B. Diethrich Arizona Heart Hospital Phoenix, AZ Powerlink System: Unibody-Bifurcated Design Long Main Body Low-Porosity Proprietary eptfe

More information

Dr Aniket Puri. OCT guided BVS for LMCA to LAD : Optimising the 'Pot'

Dr Aniket Puri. OCT guided BVS for LMCA to LAD : Optimising the 'Pot' OCT guided BVS for LMCA to LAD : Optimising the 'Pot' Dr Aniket Puri MD,DM,FRACP, FACC, FSCAI, FAPSIC Consultant Interventional Cardiologist Christchurch Hospital and Canterbury DHB(Univ of Otago) Christchurch,New

More information

DRUG-COATED BALLOONS AND CORONARY BIFURCATION LESIONS

DRUG-COATED BALLOONS AND CORONARY BIFURCATION LESIONS DRUG-COATED BALLOONS AND CORONARY BIFURCATION LESIONS *Alessandro Durante, 1 Pietro Leonida Laforgia 2 1. Ospedale Valduce, Como, Italy 2. Università degli Studi di Milano, Milan, Italy *Correspondence

More information

Ultimaster clinical results in left main and bifurcations

Ultimaster clinical results in left main and bifurcations Left main and complex bifurcation stenting clinical results in left main and bifurcations GENNARO SARDELLA MD, FACC,FESC O.U. of Interventional Cardiology Dept. of Cardiovascular and Pulmonary Sciences

More information

Bifurcations Have Met Their Match

Bifurcations Have Met Their Match Bifurcations Have Met Their Match Perspectives on clinical research and treatment from an international panel of experts Tryton Medical recently invited several leading interventional cardiologists to

More information

PCI for Ostial Lesion

PCI for Ostial Lesion PCI for Ostial Lesion ii) LAD ostial Osamu Katoh,M.D. kyoto Katsura Hospital Cardiovascular Center PCI for a LAD ostial lesion is well-known to be associated with a high restenosis rate because of excessive

More information

Session: EBC s position on dedicated devices. Pro

Session: EBC s position on dedicated devices. Pro Session: EBC s position on dedicated devices Pro Robert J. Gil 1,2, MD, PhD, FESC 1- Mossakowski Medical Research Centre, Polish Academy of Sciences 2- Invasive Cardiology Dept., Central Hospital of the

More information

Plaque Shift vs. Carina Shift Prevalence and Implication

Plaque Shift vs. Carina Shift Prevalence and Implication TCTAP 2013 Fellowship Course Left Main and Bifurcation PCI: Bifurcation PCI Plaque Shift vs. Carina Shift Prevalence and Implication Soo-Jin Kang, MD., PhD. Department of Cardiology, University of Ulsan

More information

Solving the Dilemma of Ostial Stenting: A Case Series Illustrating the Flash Ostial System

Solving the Dilemma of Ostial Stenting: A Case Series Illustrating the Flash Ostial System Volume 1, Issue 1 Case Report Solving the Dilemma of Ostial Stenting: A Case Series Illustrating the Flash Ostial System Robert F. Riley * and Bill Lombardi University of Washington Medical Center, Division

More information

INCRAFT system: Update from the Pivotal INSPIRATION Study

INCRAFT system: Update from the Pivotal INSPIRATION Study INCRAFT system: Update from the Pivotal INSPIRATION Study Michel S. Makaroun MD Co-Director, UPMC Heart and Vascular Institute Professor and Chair, Division of Vascular Surgery University of Pittsburgh

More information

Update on Tack Optimized Balloon Angioplasty (TOBA) Below the Knee. Marianne Brodmann, MD Medical University Graz Graz, Austria

Update on Tack Optimized Balloon Angioplasty (TOBA) Below the Knee. Marianne Brodmann, MD Medical University Graz Graz, Austria Update on Tack Optimized Balloon Angioplasty (TOBA) Below the Knee Marianne Brodmann, MD Medical University Graz Graz, Austria Critical Limb Ischemia Infrapopliteal arterial disease is a leading source

More information

OCTOBER. OCT Optimised Bifurcation Event Reduction. A Nordic Baltic British clinical outcome trial

OCTOBER. OCT Optimised Bifurcation Event Reduction. A Nordic Baltic British clinical outcome trial OCT Optimised Bifurcation Event Reduction A Nordic Baltic British clinical outcome trial NIELS RAMSING HOLM, Skejby Denmark Study start: OCTOBER 2016 OCTOBER LMCA or non-lmca bifurcations with SB 2.5mm

More information

ISAR-LEFT MAIN: A Randomized Clinical Trial on Drug-Eluting Stents for Unprotected Left Main Lesions

ISAR-LEFT MAIN: A Randomized Clinical Trial on Drug-Eluting Stents for Unprotected Left Main Lesions Julinda Mehilli, MD Deutsches Herzzentrum Technische Universität Munich Germany ISAR-LEFT MAIN: A Randomized Clinical Trial on Drug-Eluting Stents for Unprotected Left Main Lesions Background Left main

More information

Drug eluting stents. Where are we now and what can we expect in 2003? Tony Gershlick Leicester

Drug eluting stents. Where are we now and what can we expect in 2003? Tony Gershlick Leicester Drug eluting stents Where are we now and what can we expect in 2003? Tony Gershlick Leicester Trials Real World What we need i. Prevent restenosis cost effective Either : - Treat all at equivalent cost

More information

A Novel Low Pressure Self Expanding Nitinol Coronary Stent (vprotect): Device Design and FIH Experience

A Novel Low Pressure Self Expanding Nitinol Coronary Stent (vprotect): Device Design and FIH Experience A Novel Low Pressure Self Expanding Nitinol Coronary Stent (vprotect): Device Design and FIH Experience Juan F. Granada, MD Medical Director, Skirball Center for Cardiovascular Research The Cardiovascular

More information

September Peter Barlis. Royal Brompton Hospital, London, UK

September Peter Barlis. Royal Brompton Hospital, London, UK 3rd EBC Meeting European Bifurcation Club September 2007 PALAU DE LA MUSICA, SalaRodrigo VALENCIA, SPAIN Culotte Technique in Left Main Disease Peter Barlis Carlo DiMario Royal Brompton Hospital, London,

More information

PCI for Left Main Coronary Artery Stenosis. Jean Fajadet Clinique Pasteur, Toulouse, France

PCI for Left Main Coronary Artery Stenosis. Jean Fajadet Clinique Pasteur, Toulouse, France PCI for Left Main Coronary Artery Stenosis Jean Fajadet Clinique Pasteur, Toulouse, France Athens, October 19, 2018 Left Main Coronary Artery Disease Significant unprotected left main coronary artery disease

More information

FFR vs icecg in Coronary Bifurcations FIESTA ClinicalTrials.gov Identifier: NCT

FFR vs icecg in Coronary Bifurcations FIESTA ClinicalTrials.gov Identifier: NCT FFR vs icecg in Coronary Bifurcations FIESTA ClinicalTrials.gov Identifier: NCT01724957 Dobrin Vassilev MD, PhD Assoc. Prof. in Cardiology Head Cardiology Clinic, Alexandrovska University Hospital Medical

More information

Chronic Total Occlusion (CTO) Technologies

Chronic Total Occlusion (CTO) Technologies to receive our latest news and key activities. Chronic Total Occlusion (CTO) Technologies Re-open vital channels LinkedIn page Follow us on CORDIS EMEA OUTBACK LTD Re-Entry Catheter True Lumen Re-Entry

More information

PROMUS Element Experience In AMC

PROMUS Element Experience In AMC Promus Element Luncheon Symposium: PROMUS Element Experience In AMC Jung-Min Ahn, MD. University of Ulsan College of Medicine, Heart Institute, Asan Medical Center, Seoul, Korea PROMUS Element Clinical

More information

PCI for Left Anterior Descending Artery Ostial Stenosis

PCI for Left Anterior Descending Artery Ostial Stenosis PCI for Left Anterior Descending Artery Ostial Stenosis Why do you hesitate PCI for LAD ostial stenosis? LAD Ostial Lesion Limitations of PCI High elastic recoil Involvement of the distal left main coronary

More information

Patient. Clinical data Indications: Operation date. Comorbidities: Patient code Birth date: / /

Patient. Clinical data Indications: Operation date. Comorbidities: Patient code Birth date: / / Patient Patient code Birth date: / / Sex: Male Height (cm): Female Weight (kg): Risk Factors: Family history of coronary disease: Hypertension Dyslipidemia Peripheral disease Diabetes Comorbidities: No

More information

Drug eluting balloon for bifurcation lesion: is it useful?

Drug eluting balloon for bifurcation lesion: is it useful? Welcome to the 8 th European Bifurcation Club 12-13 October 2012 - Barcelona Drug eluting balloon for bifurcation lesion: is it useful? Dr. Bruno Garcia Hospital Universitari Vall Hebrón Barcelona (Spain)

More information

Treatment of lesions at bifurcations: General perspective

Treatment of lesions at bifurcations: General perspective ESC Congress 2011 27-31 August, Paris, France Treatment of lesions at bifurcations: General perspective Goran Stankovic MD, PhD, FESC Division of Cardiology Clinical Center of Serbia, Belgrade Serbia Potential

More information

Radiation Safety Abbott Vascular. All rights reserved.

Radiation Safety Abbott Vascular. All rights reserved. Radiation Safety More and more complex cases are performed Complexity Index and Fluoroscopy Time 2 3 Collimators / Distances The intensity of scattered radiation is a function of exposed field size Use

More information

Ostial Stents and Distal Embolic Protection During Renal Stenting

Ostial Stents and Distal Embolic Protection During Renal Stenting Ostial Stents and Distal Embolic Protection During Renal Stenting John R. Laird, MD Professor of Medicine Director of the Vascular Center UC Davis Medical Center Limitations of Current Techniques of Renal

More information

Innovation in Transradial access. Aminian Adel, MD CHU Charleroi Belgium

Innovation in Transradial access. Aminian Adel, MD CHU Charleroi Belgium Innovation in Transradial access Aminian Adel, MD CHU Charleroi Belgium Potential conflicts of interest Speaker's name: Adel Aminian I do not have any potential conflict of interest Limitations of TR access?

More information

Final Clinical and Angiographic Results From a Nationwide Registry of FIREBIRD Sirolimus- Eluting Stent: Firebird In China (FIC) Registry (PI R. Gao)

Final Clinical and Angiographic Results From a Nationwide Registry of FIREBIRD Sirolimus- Eluting Stent: Firebird In China (FIC) Registry (PI R. Gao) The Microport FIREBIRD Polymer-based Sirolimus- Eluting Stent Clinical Trial Program Update: The FIC and FIREMAN Registries Junbo Ge, MD, FACC, FESC, FSCAI On behalf of Runlin Gao (FIC PI) and Haichang

More information

Medtronic Symposium The Complex Bifurcation Patient: new insights into stent selection

Medtronic Symposium The Complex Bifurcation Patient: new insights into stent selection Medtronic Symposium The Complex Bifurcation Patient: new insights into stent selection Carlo Trani, MD, FESC Cardiology Department, Catholic University of the Sacred Heart, Rome - Italy How would you treat

More information

MULTIVESSEL PCI. IN DRUG-ELUTING STENT RESTENOSIS DUE TO STENT FRACTURE, TREATED WITH REPEAT DES IMPLANTATION

MULTIVESSEL PCI. IN DRUG-ELUTING STENT RESTENOSIS DUE TO STENT FRACTURE, TREATED WITH REPEAT DES IMPLANTATION MULTIVESSEL PCI. IN DRUG-ELUTING STENT RESTENOSIS DUE TO STENT FRACTURE, TREATED WITH REPEAT DES IMPLANTATION C. Graidis, D. Dimitriadis, A. Ntatsios, V. Karasavvides Euromedica Kyanous Stavros, Thessaloniki.

More information

Chronic Total Occlusion (CTO) Technologies. Re-open vital channels

Chronic Total Occlusion (CTO) Technologies. Re-open vital channels Chronic Total Occlusion (CTO) Technologies Re-open vital channels OUTBACK LTD Re-Entry Catheter True Lumen Re-Entry Technology Get back into the true lumen with ease and precision There are a number of

More information

Lessons for technique and stent choice

Lessons for technique and stent choice 8 th European Bifurcation Club 12-13 October 2012 - Barcelona Session: What are the requirements for using a stent in a bifurcation? Lessons for technique and stent choice October 12 th : 16:45 17:50 Goran

More information

Christian Wissgott MD, PhD Assistant Director, Radiology Westküstenkliniken Heide

Christian Wissgott MD, PhD Assistant Director, Radiology Westküstenkliniken Heide 2-Year Results Of The Tack Optimized Balloon Angioplasty (TOBA) Trial For Fem- Pop Lesions Demonstrates Safety and Efficacy Of The Tack Endovascular System In Repairing Focal Post-PTA Dissections Christian

More information

Final Results of the Feasibility Study for the Drug-coated Chocolate Touch PTA balloon. (The ENDURE Trial)

Final Results of the Feasibility Study for the Drug-coated Chocolate Touch PTA balloon. (The ENDURE Trial) Final results of the feasibility study for the drug-coated Chocolate Touch PTA balloon of of femoropopliteal Femoropopliteal lesions lesions: (The ENDURE Trial) Final Results of the Feasibility Study for

More information

What's on the Horizon for AAA: Unilateral & Percutaneous, "UP-EVAR" System Zoran Rancic M.D., Ph.D.

What's on the Horizon for AAA: Unilateral & Percutaneous, UP-EVAR System Zoran Rancic M.D., Ph.D. What's on the Horizon for AAA: Unilateral & Percutaneous, "UP-EVAR" System Zoran Rancic M.D., Ph.D. Clinic for Cardiovascular Surgery University Hospital Zurich DISCLOSURES COMMON SITUATIONS FOR UNILATERAL

More information

Stent Thrombosis in Bifurcation Stenting

Stent Thrombosis in Bifurcation Stenting Summit TCT Asia Pacific 2009 Stent Thrombosis in Bifurcation Stenting Associate Professor Tan Huay Cheem MBBS, M Med(Int Med), MRCP, FRCP(UK), FAMS, FACC, FSCAI Director, National University Heart Centre,

More information

PCI for Long Coronary Lesion

PCI for Long Coronary Lesion PCI for Long Coronary Lesion Shift of a General Idea with the Introduction of DES In the Bare Metal Stent Era Higher Restenosis Rate With Increasing Stent Length and Decreasing Stent Area Restenosis.6.4.2

More information

Unprotected left main coronary stenting with a second generation drug-eluting stent. One-year clinical follow-up of the LeMaX pilot study.

Unprotected left main coronary stenting with a second generation drug-eluting stent. One-year clinical follow-up of the LeMaX pilot study. Unprotected left main coronary stenting with a second generation drug-eluting stent. One-year clinical follow-up of the LeMaX pilot study. N. Boudou, N. Salvatella, N. Dumonteil, M.C. Morice, O. Darremont,

More information

Making the difference with Live Image Guidance

Making the difference with Live Image Guidance Interventional Cardiology AlluraClarity Making the difference with Live Image Guidance Diagnosis and treatment of coronary artery diseases and atherosclerosis Where/who The First Bethune Hospital of Jilin

More information

Final Results of the Feasibility Study for the Drug-coated Chocolate Touch PTA balloon. (The ENDURE Trial)

Final Results of the Feasibility Study for the Drug-coated Chocolate Touch PTA balloon. (The ENDURE Trial) Final results of the feasibility study for the drug-coated Chocolate Touch PTA balloon of of femoropopliteal Femoropopliteal lesions lesions: (The ENDURE Trial) Final Results of the Feasibility Study for

More information

TCTAP Upendra Kaul MD,DM,FACC,FSCAI,FAMS,FCSI

TCTAP Upendra Kaul MD,DM,FACC,FSCAI,FAMS,FCSI Indian TUXEDO Trial In Medically Treated Diabetics Upendra Kaul MD,DM,FACC,FSCAI,FAMS,FCSI Executive Director and Dean Escorts Heart Institute & Medical Research Center and Fortis Hospitals, New Delhi

More information

IVUS-Guided d Provisional i Stenting: Plaque or Carina Shift. Soo-Jin Kang, MD., PhD.

IVUS-Guided d Provisional i Stenting: Plaque or Carina Shift. Soo-Jin Kang, MD., PhD. Left Main and Bifurcation Summit IVUS-Guided d Provisional i Stenting: ti Plaque or Carina Shift Soo-Jin Kang, MD., PhD. Department of Cardiology, University of Ulsan College of Medicine Asan Medical Center,

More information

Bench Insights into Bifurcation Stenting in the DES Era: An Update

Bench Insights into Bifurcation Stenting in the DES Era: An Update Bench Insights into Bifurcation Stenting in the DES Era: An Update John Ormiston, Mark Webster, Peter Ruygrok, Jim Stewart, Douglas Scott, Duncan McNabb, Erin Currie, Monique Panther Mercy Hospital and

More information

FFR vs. icecg in Coronary Bifurcations (FIESTA) - preliminary results. Dobrin Vassilev MD, PhD National Heart Hospital Sofia, Bulgaria

FFR vs. icecg in Coronary Bifurcations (FIESTA) - preliminary results. Dobrin Vassilev MD, PhD National Heart Hospital Sofia, Bulgaria FFR vs. icecg in Coronary Bifurcations (FIESTA) - preliminary results Dobrin Vassilev MD, PhD National Heart Hospital Sofia, Bulgaria I would like to express my personal gratitude to Dr. BK Koo for opening

More information

Seeing double: the double kissing crush stenting technique for coronary bifurcation lesions

Seeing double: the double kissing crush stenting technique for coronary bifurcation lesions xxxxxxx editorial Seeing double: the double kissing crush stenting technique for coronary bifurcation lesions In the drug-eluting stent era, interventionalists continue to face the traditional problems:

More information

Biliary Metal Stents MAKING A DIFFERENCE TO HEALTH

Biliary Metal Stents MAKING A DIFFERENCE TO HEALTH Biliary Metal Stents In a fast paced and maturing market, Diagmed Healthcare s Hanarostent has managed to continue to innovate and add unique and clinically superior features to its already premium range.

More information

Bioabsorbable Scaffolding: Technology and Clinical Update. PD Dr. Nicolas Diehm, MD, FESC Inselspital, University Hospital Bern, Switzerland

Bioabsorbable Scaffolding: Technology and Clinical Update. PD Dr. Nicolas Diehm, MD, FESC Inselspital, University Hospital Bern, Switzerland Bioabsorbable Scaffolding: Technology and Clinical Update PD Dr. Nicolas Diehm, MD, FESC Inselspital, University Hospital Bern, Switzerland Disclosures I am not Ron Waksman 1 Clinical experience with AMS

More information

Basics of Angiographic Interpretation Analysis of Angiography

Basics of Angiographic Interpretation Analysis of Angiography Basics of Angiographic Interpretation Analysis of Angiography Young-Hak Kim, MD, PhD Cardiac Center, University of Ulsan College of Medicine, Seoul, Korea What made us nervous Supervisors Stent Contrast

More information