Screening Patients for the Transcatheter Aortic Valve Replacement (TAVR) Procedure. A Guide for Referring Physicians

Size: px
Start display at page:

Download "Screening Patients for the Transcatheter Aortic Valve Replacement (TAVR) Procedure. A Guide for Referring Physicians"

Transcription

1 Screening Patients for the Transcatheter Aortic Valve Replacement (TAVR) Procedure A Guide for Referring Physicians

2 TAVR Patient Screening Flow Patient is diagnosed with symptomatic severe native calcific aortic stenosis and referred to the Heart Team for evaluation The aortic valvular complex is evaluated using echocardiography The aortic valvular complex and peripheral vasculature are evaluated using MDCT

3 4 5 6 The aortic valvular complex and peripheral vasculature are evaluated using catheterization Patient is evaluated by the Heart Team and meets the indication for TAVR Appropriate access route for TAVR procedure is determined by the Heart Team The above is a suggested flow for the patient screening process, however, the order in which screening tests are conducted varies depending on the patient s profile and should be at the discretion of the Heart Team.

4 This guide provides an overview of the screening process used by Heart Teams to evaluate patients for transcatheter aortic valve replacement (TAVR) with the Edwards SAPIEN XT transcatheter heart valve. Please visit to locate a Heart Team and TAVR center near you.

5 1 Patient is Diagnosed with Symptomatic Severe Native Calcific Aortic Stenosis An Overview of the 2014 AHA/ACC Valvular Heart Disease Guidelines - Symptomatic Severe Aortic Stenosis 1 Symptoms of severe aortic stenosis include: dyspnea or decreased exercise tolerance, heart failure, angina, syncope and presyncope. Patients with severe aortic stenosis typically have an aortic valve area < 1.0 cm 2 Hemodynamic Stage Definition Valve Hemodynamics Consequences D: Symptomatic Severe Aortic Stenosis 50% After the onset of symptoms, patients with severe aortic stenosis have a survival rate as low as 50% at 2 years without aortic valve replacement. 2 D1 High-gradient Aortic jet velocity > 4m/s or mean gradient > 40 mmhg Or aortic valve area index < 0.6 cm 2 /m 2 Left ventricular diastolic dysfunction Left ventricular hypertrophy Pulmonary hypertension may be present D2 Low-flow/low-gradient with reduced left ventricular ejection fraction Resting aortic jet velocity < 4m/s or mean gradient < 40 mmhg Dobutamine stress echocardiography shows aortic valve area < 1.0 cm 2 with aortic jet velocity > 4m/s at any flow rate Left ventricular diastolic dysfunction Left ventricular hypertrophy Left ventricular ejection fraction < 50% D3 Low-gradient with normal left ventricular ejection fraction or paradoxical low-flow Aortic jet velocity < 4m/s or mean gradient < 40 mmhg Stroke volume index < 35 ml/m 2 measured when patient is normotensive (systolic blood pressure < 140 mmhg) Increased left ventricular relative wall thickness Small left ventricular chamber with low stroke volume Restrictive diastolic filling Left ventricular ejection fraction > 50%

6 2 The Aortic Valvular Complex is Evaluated Using Echocardiography After a patient is diagnosed with symptomatic severe native calcific aortic stenosis, patients will need various imaging tests to assess if they are appropriate candidates for the transcatheter heart valve and delivery method. Comprehensive imaging tests will assess: the aortic valvular complex, cardiac structures and function, aortic arch, and peripheral vessels. Transthoracic Echocardiography (TTE) is generally the first approach in assessing the annulus size due to its non-invasiveness TTE underestimates the annulus size and is typically used to obtain an estimation of annulus size Transesophageal Echocardiography (TEE) is used to confirm annulus size when TTE measurements are borderline or the image quality is poor A B TTE (A) should occur in a parasternal long-axis view 3 TEE (B) should occur in a left ventricular long-axis view (~120 ) 3

7 Transesophageal Echocardiography is used to evaluate the size of the aortic annulus When the annulus size is assessed by TEE: Measurements are taken during systole at the plane of the hinge points of the native valve leaflets at the largest diameter The long-axis plane is positioned between the left and non-coronary cusps and through the right coronary cusp Systole Diastole Oblique Measurement

8 3 The Aortic Valvular Complex and Peripheral Vasculature are Evaluated Using MDCT Gated Multi-Detector Computed Tomography (MDCT) is used to evaluate the size of the aortic annulus Annulus assessment via ECG-gated cardiac MDCT and 3D echocardiography allows the evaluation of the annulus in an orthogonal plane at the level of the basal ring 4 The annulus is a dynamic structure that changes shape during the cardiac cycle: 5 Largest during systole Smaller and more ovoid during diastole It is critical to obtain accurate sizing measurements and it is recommended to use a systolic series obtained from MDCT Patient is not moving during acquisition ECG triggered or gated CT Contrast-enhanced Slice thickness of heart (less than) 1 mm Dose modulation switched off or only used for diastole (drop in diastole increase in systole) Sinotubular Junction Aortic Leaflets Virtual Ring formed by joining basal attachments of aortic leaflets Reconstruct in 5-10% increments from 25% - 45% of the R-R interval which helps ensure the maximum area is determined

9 14 mm 17 mm 19 mm 23 mm THV Size to Annulus Size* 26 mm 29 mm THV Size 23 mm 26 mm 29 mm Native Valve Annulus Size (TEE) mm mm mm Native Valve Annulus Size (CT) Area mm mm mm 2 Native Valve Annulus Size (CT) Area Derived Diameter mm mm mm *THV size recommendations are based on native valve annulus size, as measured by transesophageal echocardiography (TEE) or computed tomography (CT). Patient anatomical factors and multiple imaging modalities should be considered during THV size selection. Note: Risks associated with undersizing and oversizing should be considered.

10 3 The Aortic Valvular Complex and Peripheral Vasculature are Evaluated Using MDCT Gated MDCT is used to evaluate the aortic valvular complex: Location and extent of leaflet calcification is evaluated For transapical patients, preoperative chest CT may be helpful in determining the orientation of the apex to determine suitability for access For transaortic patients, preoperative chest CT may be helpful in determining the anatomical relationship of the sternum and ascending aorta 6

11 MDCT is used to evaluate the peripheral vasculature to determine patient appropriateness for the transfemoral procedure: Minimum lumen diameters should be measured along the length of the common femoral, external iliac and common iliac arteries Internal diameter measurements should not include calcium Recommended Minimum Vessel Diameters for Implantation of the Edwards SAPIEN XT Transcatheter Heart Valve Edwards SAPIEN XT THV Size Suggested minimum vessel size 23 mm 26 mm 29 mm 6 mm 6.5 mm 7 mm esheath profile 16F 18F 20F Note: For patients with renal failure, non-contrast CT or IVUS of the iliac may be used to evaluate the extent of calcification in the vessel and estimate vessel diameter

12 4 The Aortic Valvular Complex and Peripheral Vasculature are Evaluated Using Catheterization The following may be evaluated using catheterization: Degree of calcification and tortuosity of the peripheral vasculature Qualitative assessment of angulation and degree of stenosis of the aortic arch and distance of the coronary ostia from the aortic annulus

13 Assessment of the coronary arteries to determine if revascularization is necessary

14 5 Patient is Evaluated by the Heart Team and Meets the Indication for TAVR According to the National Coverage Determination Memo published by the Centers for Medicare and Medicaid Services (CMS), two cardiac surgeons must independently examine the patient face-to-face and evaluate the patient s suitability for open aortic valve replacement surgery; both surgeons are required to document the rationale for their clinical judgement and make this rationale available to the Heart Team. HIGH OR GREATER RISK PATIENTS: who are judged by a Heart Team, including a cardiac surgeon, may be considered for TAVR if they have an STS operative risk score of 8% or are at a 15% risk of mortality at 30 days. See page 18 and 19 for indications and Important Risk Information. In addition, some patients may have a low STS score but present with co-existing conditions that prevent the patient from being a suitable candidate for surgery. These conditions include 7 : Extensively calcified (porcelain) aorta Chest wall deformity Oxygen-dependent respiratory insufficiency Frailty

15 6 Appropriate Access Route for Aortic TAVR Procedure is Determined Transfemoral Approach Transapical Approach Transaortic Approach

16 6 Appropriate Access Route for Aortic TAVR Procedure is Determined Anatomy Diameter of iliac and femoral arteries Transfemoral Approach Recommended Femoral and iliac arteries 6 mm for 23 mm valve, 6.5 mm for 26 mm valve and 7 mm for 29 mm valve Calcification of iliac and femoral arteries Tortuosity of iliac and femoral arteries Ventricle Aorta No significant calcification of the femoral or iliac arteries No significant calcification of the aortic bifurcation No severe tortuosity of the arterial pathway from the femoral artery to the aortic bifurcation Severe LV dysfunction Hostile apex LV aneurysm Dyskinetic ventricle Quality of the tissue frail, immunosuppressed patients Myocardial injury Severe COPD No significant aortic disease, including no aneurysm, no presence of severe tortuosity and/or narrowing No horizontal aortic root and vertical valve plane No acute aortic arch angulation No aortic arch atheroma

17 Transapical Approach Recommended Femoral and/or iliac arteries < 6 mm for 23 mm valve, < 6.5 mm and for 26 mm valve, and < 7 mm for 29 mm valve Iliofemoral bypass Extensive calcification of the femoral and/or iliac arteries Extensive calcification of aortic bifurcation Severe tortuosity of the arterial pathway from the femoral artery to the aortic bifurcation Free from pericardial disease or dyskinetic or aneurysmal ventricular apex Significant aortic disease including aneurysm, severe tortuosity and/or narrowing Horizontal aortic root without vertical valve plane Acute aortic arch angulation Aortic arch atheroma Significant aortic valve calcification with bulky leaflets wherein retrograde crossing may be problematic Transaortic Approach Recommended Femoral and/or iliac arteries < 6 mm for 23 mm valve, < 6.5 mm and for 26 mm valve, and < 7 mm for 29 mm valve Iliofemoral bypass Extensive calcification of the femoral and/or iliac arteries Extensive calcification of aortic bifurcation Severe tortuosity of the arterial pathway from the femoral artery to the aortic bifurcation Severe LV dysfunction Hostile apex LV aneurysm Dyskinetic ventricle Quality of the tissue frail, immunosuppressed patients Myocardial injury Severe COPD Adequate distance from puncture to aortic annular plane (5.0 cm for 23 mm valve, 5.5 cm for 26 mm valve and 6.0 cm for 29 mm valve) No significant aortic disease, including no aneurysm No aortic arch atheroma No excessive calcification of aorta at access site

18 Why recommend an Edwards transcatheter heart valve for your patient? The Edwards SAPIEN transcatheter heart valve platform is designed to imitate surgical valves in design and outcomes. They are the most widely used transcatheter heart valves worldwide and consistently demonstrate clinical excellence in both trials and real-world experience. Designed for Durability Edwards transcatheter heart valves use proven tissue and leverage the manufacturing processes of our leading surgical heart valves which have over 20 years of durability data. Low Incidence of Complications and Permanent Pacemakers Low frame height minimizes the risk of coronary obstruction and conduction system interference. SAPIEN valves consistently demonstrate low rates of permanent pacemaker implantation. Optimal Hemodynamic Performance The balloon-expandable, high radial strength frame is designed to achieve circularity* at the annulus to maximize area and flow while promoting full expansion and apposition at the annulus to minimize aortic regurgitation. The Edwards SAPIEN XT transcatheter heart valve, model 9300TFX, systems are indicated for relief of aortic stenosis in patients with symptomatic heart disease due to severe native calcific aortic stenosis (aortic valve area 1.0 cm 2 or aortic valve area index 0.6 cm 2 /m 2, a mean aortic valve gradient of 40 mmhg, or a peak aortic-jet velocity of 4.0 m/s), and with native anatomy appropriate for the 23, 26, or 29 mm valve system, who are judged by a heart team, including a cardiac surgeon, to be at high or greater risk for open surgical therapy (i.e., Society of Thoracic Surgeons operative risk score 8% or at a 15% risk of mortality at 30 days). *Data on file at Edwards Lifesciences

19 IMPORTANT RISK INFORMATION Available Valve Sizes 23 mm 26 mm 29 mm The 23 mm, 26 mm, and 29 mm sizes of the Edwards SAPIEN XT valve are designed to treat an annulus size range of mm on TEE and mm on CT.

20 References 1. Nishimura RA, Otto CM, Bonow RO, Carabello BA, Erwin JP III, Guyton RA,O Gara PT, Ruiz CE, Skubas NJ, Sorajja P, Sundt TM III, Thomas JD, 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: Executive Summary, Journal of the American College of Cardiology (2014), doi: /j.jacc Otto CM. Timing of aortic valve surgery. Heart. 2000;84: Delgado, V, et al. Pre-Operative Aortic Valve Implantation Evaluation: Multimodality Imaging. EuroIntervention Supplement 6.G (2010): G Leipsic, Jonathon, Gurvitch, Ronen, et.al. Multidetector Computed Tomography in Transcatheter Aortic Valve Implantation. JACC. 2011; 4(4): Achenbach, Stephan, Victoria Delgado, Jörg Hausleiter, Paul Schoenhagen, James K. Min, and Jonathon A. Leipsic. SCCT Expert Consensus Document on Computed Tomography Imaging before Transcatheter Aortic Valve Implantation (TAVI)/transcatheter Aortic Valve Replacement (TAVR). Journal of Cardiovascular Computed Tomography 6.6 (2012): Bapat V, Attia R., Transaortic Transcatheter Aortic Valve Implantation: Step-by-Step Guide., Semin Thorac Cardiovasc Surg Autumn;24(3): Leon M, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010;363(17): See accompanying Important Risk Information. CAUTION: Federal (United States) law restricts these devices to sale by or on the order of a physician. See Important Risk Information for full prescribing information, including indications, contraindications, warnings, precautions and adverse events. Edwards, Edwards Lifesciences, the stylized E logo, Edwards SAPIEN, Edwards SAPIEN XT, esheath, NewHeartValve.com, SAPIEN and SAPIEN XT are trademarks of Edwards Lifesciences Corporation. All other trademarks are the property of their respective owners Edwards Lifesciences Corporation. All rights reserved. AR11852 Edwards Lifesciences I edwards.com One Edwards Way I Irvine, California USA Switzerland I Japan I China I Brazil I Australia I India

21 IMPORTANT RISK INFORMATION EDWARDS SAPIEN XT TRANSCATHETER HEART VALVE WITH THE NOVAFLEX+ DELIVERY SYSTEM Indications: The Edwards SAPIEN XT Transcatheter Heart Valve, model 9300TFX, systems are indicated for relief of aortic stenosis in patients with symptomatic heart disease due to severe native calcific aortic stenosis (aortic valve area 1.0 cm 2 or aortic valve area index 0.6 cm 2 /m 2, a mean aortic valve gradient of 40 mmhg, or a peak aortic-jet velocity of 4.0 m/s), and with native anatomy appropriate for the 23, 26, or 29 mm valve system, who are judged by a heart team, including a cardiac surgeon, to be at high or greater risk for open surgical therapy (i.e., Society of Thoracic Surgeons operative risk score 8% or at a 15% risk of mortality at 30 days). Contraindications: The THV and delivery systems are contraindicated in patients who cannot tolerate an anticoagulation/antiplatelet regimen or who have active bacterial endocarditis or other active infections. Warnings: Observation of the pacing lead throughout the procedure is essential to avoid the potential risk of pacing lead perforation. There is an increased risk of stroke in transcatheter aortic valve replacement procedures, as compared to balloon aortic valvuloplasty or other standard treatments. The devices are designed, intended, and distributed for single use only. Do not resterilize or reuse the devices. There are no data to support the sterility, nonpyrogenicity, and functionality of the devices after reprocessing. Incorrect sizing of the THV may lead to paravalvular leak, migration, embolization and/or annular rupture. Accelerated deterioration of the THV may occur in patients with an altered calcium metabolism. Prior to delivery, the THV must remain hydrated at all times and cannot be exposed to solutions other than its shipping storage solution and sterile physiologic rinsing solution. THV leaflets mishandled or damaged during any part of the procedure will require replacement of the THV. Caution should be exercised in implanting a THV in patients with clinically significant coronary artery disease. Patients with preexisting mitral valve devices should be carefully assessed prior to implantation of the THV to ensure proper THV positioning and deployment. Do not use the THV if the tamper evident seal is broken, the storage solution does not completely cover the THV, the temperature indicator has been activated, the THV is damaged, or the expiration date has elapsed. Do not mishandle the NovaFlex+ delivery system or use it if the packaging or any components are not sterile, have been opened or are damaged (e.g., kinked or stretched), or the expiration date has elapsed. Use of excessive contrast media may lead to renal failure. Measure the patient s creatinine level prior to the procedure. Contrast media usage should be monitored. Patient injury could occur if the delivery system is not un-flexed prior to removal. Care should be exercised in patients with hypersensitivities to cobalt, nickel, chromium, molybdenum, titanium, manganese, silicon, and/or polymeric materials. The procedure should be conducted under fluoroscopic guidance. Some fluoroscopically guided procedures are associated with a risk of radiation injury to the skin. These injuries may be painful, disfiguring, and long-lasting. THV recipients should be maintained on anticoagulant/antiplatelet therapy, except when contraindicated, as determined by their physician. This device has not been tested for use without anticoagulation. Do not add or apply antibiotics to the storage solution, rinse solutions, or to the THV. Precautions: Long-term durability has not been established for the THV. Regular medical follow-up is advised to evaluate THV performance. Glutaraldehyde may cause irritation of the skin, eyes, nose and throat. Avoid prolonged or repeated exposure to, or breathing of, the solution. Use only with adequate ventilation. If skin contact occurs, immediately flush the affected area with water; in the event of contact with eyes, seek immediate medical attention. For more information about glutaraldehyde exposure, refer to the Material Safety Data Sheet available from Edwards Lifesciences. To maintain proper valve leaflet coaptation, do not overinflate the deployment balloon. Appropriate antibiotic prophylaxis is recommended post-procedure in patients at risk for prosthetic valve infection and endocarditis. Safety, effectiveness, and durability have not been established for valve-invalve procedures. Safety and effectiveness have not been established for patients with the following characteristics/comorbidities: non-calcified aortic annulus, severe ventricular dysfunction with ejection fraction < 20%, congenital unicuspid or congenital bicuspid aortic valve, mixed aortic valve disease (aortic stenosis and aortic regurgitation with predominant aortic regurgitation > 3+), pre-existing prosthetic heart valve or prosthetic ring in any position, severe mitral annular calcification (MAC), severe (> 3+) mitral insufficiency, or Gorlin syndrome, blood dyscrasias defined as: leukopenia (WBC < 3000 cells/ml), acute anemia (Hb < 9 g/dl), thrombocytopenia (platelet count <50,000 cells/ ml),or history of bleeding diathesis or coagulopathy, hypertrophic cardiomyopathy with or without obstruction (HOCM), echocardiographic evidence of intracardiac mass, thrombus, or vegetation, a known hypersensitivity or contraindication to aspirin, heparin, ticlopidine (Ticlid ), or clopidogrel (Plavix ), or sensitivity to contrast media, which cannot be adequately premedicated, significant aortic disease, including abdominal aortic or thoracic aneurysm defined as maximal luminal diameter 5 cm or greater; marked tortuosity (hyperacute bend), aortic arch atheroma (especially if thick [> 5 mm], protruding, or ulcerated) or narrowing (especially with calcification and surface irregularities) of the abdominal or thoracic aorta, severe unfolding and tortuosity of the thoracic aorta, access characteristics that would preclude safe placement of 16F, 18F, or 20F Edwards Expandable Introducer Sheath Set, such as severe obstructive calcification, severe tortuosity or diameter less than 6 mm, 6.5 mm, or 7 mm, respectively, bulky calcified aortic valve leaflets in close proximity to coronary ostia. Potential Adverse Events: Potential risks associated with the overall procedure including potential access complications associated with standard cardiac catheterization, balloon valvuloplasty, the potential risks of conscious sedation and/or general anesthesia, and the use of angiography: death; stroke/transient ischemic attack, clusters or neurological deficit; paralysis; permanent disability; respiratory insufficiency or respiratory failure; hemorrhage requiring transfusion or intervention; cardiovascular injury including perforation or dissection of vessels, ventricle, myocardium or valvular structures that may require intervention; pericardial effusion or cardiac tamponade; embolization including air, calcific valve material or thrombus; infection including septicemia and endocarditis; heart failure; myocardial infarction; renal insufficiency or renal failure; conduction system defect which may require a permanent pacemaker; arrhythmia; retroperitoneal bleed; AV fistula or pseudoaneurysm; reoperation; ischemia or nerve injury; restenosis; pulmonary edema; pleural effusion; bleeding; anemia; abnormal lab values (including electrolyte imbalance); hypertension or hypotension; allergic reaction to anesthesia, contrast media, or device materials; hematoma; syncope; pain or changes at the access site; exercise intolerance or weakness; inflammation; angina; heart murmur; fever. Additional potential risks associated with the use of the THV, delivery system, and/or accessories include: cardiac arrest; cardiogenic shock; emergency cardiac surgery; cardiac failure or low cardiac output; coronary flow obstruction/transvalvular flow disturbance; device thrombosis requiring intervention; valve thrombosis; device embolization; device migration or malposition requiring intervention; valve deployment in unintended location; valve stenosis; structural valve deterioration (wear, fracture, calcification, leaflet tear/tearing from the stent posts, leaflet retraction, suture line disruption of components of a prosthetic valve, thickening, stenosis); device degeneration; paravalvular or transvalvular leak; valve regurgitation; hemolysis; device explants; nonstructural dysfunction; mechanical failure of delivery system, and/or accessories, non-emergent reoperation. EDWARDS BALLOON CATHETER (9350BC20 and 9350BC23) Indications: The Edwards balloon catheter is indicated for valvuloplasty of a stenotic aortic valve prior to implantation of the Edwards SAPIEN and SAPIEN XT transcatheter heart valves. Contraindications: Other than standard risks associated with insertion of a cardiovascular catheter, there are no known contraindications for valvuloplasty. The patient s medical condition could affect successful use of this catheter. Warnings: The device is designed, intended, and distributed for single use only. Do not resterilize or reuse the device. There are no data to support the sterility, nonpyrogenicity, and functionality of the device after reprocessing. Do not mishandle the device or use it if the packaging or any components are not sterile, have been opened or are damaged (e.g. kinked or stretched), or the expiration date has elapsed. Precautions: For special considerations associated with the use of this device prior to transcatheter heart valve implantation, refer to the bioprosthesis Instructions for Use (IFU). Use only appropriate balloon inflation medium. Do not use air or gaseous medium to inflate the balloon. The device is not intended for post-dilatation of deployed transcatheter heart valves. While exposed within the body, device advancement and retrieval should not be done without the aid of fluoroscopy. Do not advance or retract the device unless the balloon is fully deflated under vacuum. Potential Adverse Events: Complications associated with standard catheterization, balloon valvuloplasty, and the use of angiography include, but are not limited to, allergic reaction to anesthesia or to contrast media, injury including perforation or dissection of vessels, thrombus formation, plaque dislodgement and embolization that may result in myocardial infarction, stroke, distal peripheral occlusion and/or death, arrhythmia development, cardiac perforation, conduction system injury, hematoma, infundibulum injury, annular tear or rupture and/or valve leaflet dehiscence, severe valve insufficiency, valve restenosis, valve damage, balloon rupture, balloon separation following balloon rupture, valvular tearing or trauma, thromboembolic events, and infection. Reference the Edwards SAPIEN Transcatheter Heart Valve with RetroFlex 3 Delivery System, or the Edwards SAPIEN XT Transcatheter Heart Valve with the NovaFlex+ Delivery System Instructions for Use, for a full list of potential adverse events. EDWARDS BALLOON CATHETER (9350BC25) Indications: The Edwards balloon catheter is indicated for valvuloplasty of a stenotic aortic valve prior to implantation of the Edwards SAPIEN XT transcatheter heart valve. Contraindications: Other than standard risks associated with insertion of a cardiovascular catheter, there are no known contraindications for valvuloplasty. The patient s medical condition could affect successful use of this catheter. Warnings: The device is designed, intended, and distributed for single use only. Do not resterilize or reuse the device. There are no data to support the sterility, nonpyrogenicity, and functionality of the device after reprocessing. Do not mishandle the device or use it if the packaging or any components are not sterile, have been opened or are damaged (e.g. kinked or stretched), or the expiration date has elapsed. Precautions: For special considerations associated with the use of this device prior to transcatheter heart valve implantation, refer to the bioprosthesis Instructions for Use. Use only appropriate balloon inflation medium. Do not use air or gaseous medium to inflate the balloon. The device is not intended for post-dilatation of deployed transcatheter heart valves. While exposed within the body, device advancement and retrieval should not be done without the aid of fluoroscopy. Do not advance or retract the device unless the balloon is fully deflated under vacuum. Potential Adverse Events: Complications associated with standard catheterization, balloon valvuloplasty, and the use of angiography include, but are not limited to, allergic reaction to anesthesia or to contrast media, injury including perforation or dissection of vessels, thrombus formation, plaque dislodgement and embolization that may result in myocardial infarction, stroke, distal peripheral occlusion and/or death, arrhythmia development, cardiac perforation, conduction system injury, hematoma, infundibulum injury, annular tear or rupture and/or valve leaflet dehiscence, severe valve insufficiency, valve restenosis, valve damage, balloon rupture, balloon separation following balloon rupture, valvular tearing or trauma, thromboembolic events, and infection. Reference the Edwards SAPIEN XT Transcatheter Heart Valve with the NovaFlex+ Delivery System Instructions for Use for a full list of potential adverse events. EDWARDS EXPANDABLE INTRODUCER SHEATH SET Indications: The Edwards expandable introducer sheath is indicated for the introduction and removal of devices used with the Edwards SAPIEN XT Transcatheter Heart Valve. Contraindications: This product is contraindicated for tortuous or calcified vessels that would prevent safe entry of the introducer and sheath. Warnings: The devices are designed, intended, and distributed for single use only. Do not resterilize or reuse the devices. There is no data to support the sterility, nonpyrogenicity, and functionality of the devices after reprocessing. The Edwards Expandable Introducer Sheath Set must be used with a compatible guidewire. Precautions: Do not use the introducer sheath set if the packaging sterile barriers and any components have been opened or damaged. The Edwards Expandable Sheath temporarily enlarges to allow the passage of devices; ensure that the vasculature can accommodate the maximum diameter of the expanded sheath. When inserting, manipulating or withdrawing a device through the expandable sheath, always maintain sheath position. When puncturing, suturing or incising the tissue near the sheath, use caution to avoid damage to the sheath. Potential Adverse Events: Complications associated with standard catheterization and use of angiography include, but are not limited to, injury including perforation or dissection of vessels, thrombosis, and/or plaque dislodgement which may result in emboli formation, distal vessel obstruction, stroke, infection, and/or death.

22 IMPORTANT RISK INFORMATION EDWARDS SAPIEN XT TRANSCATHETER HEART VALVE WITH THE ASCENDRA+ DELIVERY SYSTEM Indications: The Edwards SAPIEN XT Transcatheter Heart Valve, model 9300TFX, systems are indicated for relief of aortic stenosis in patients with symptomatic heart disease due to severe native calcific aortic stenosis (aortic valve area 1.0 cm 2 or aortic valve area index 0.6 cm 2 /m 2, a mean aortic valve gradient of 40 mmhg, or a peak aortic-jet velocity of 4.0 m/s), and with native anatomy appropriate for the 23, 26, or 29 mm valve system, who are judged by a heart team, including a cardiac surgeon, to be at high or greater risk for open surgical therapy (i.e., Society of Thoracic Surgeons operative risk score 8% or at a 15% risk of mortality at 30 days). Contraindications: The THV and delivery systems are contraindicated in patients who cannot tolerate an anticoagulation/antiplatelet regimen or who have active bacterial endocarditis or other active infections. Warnings: Observation of the pacing lead throughout the procedure is essential to avoid the potential risk of pacing lead perforation. There is an increased risk of stroke in transcatheter aortic valve replacement procedures, as compared to balloon aortic valvuloplasty or other standard treatments. The devices are designed, intended, and distributed for single use only. Do not resterilize or reuse the devices. There are no data to support the sterility, nonpyrogenicity, and functionality of the devices after reprocessing. Incorrect sizing of the THV may lead to paravalvular leak, migration, embolization and/or annular rupture. Accelerated deterioration of the THV may occur in patients with an altered calcium metabolism. Prior to delivery, the THV must remain hydrated at all times and cannot be exposed to solutions other than its shipping storage solution and sterile physiologic rinsing solution. THV leaflets mishandled or damaged during any part of the procedure will require replacement of the THV. Caution should be exercised in implanting a THV in patients with clinically significant coronary artery disease. Patients with preexisting mitral valve devices should be carefully assessed prior to implantation of the THV to ensure proper THV positioning and deployment. Patients presenting with combination AV low flow, low gradient should undergo additional evaluation to establish the degree of aortic stenosis. Do not use the THV if the tamper evident seal is broken, the storage solution does not completely cover the THV, the temperature indicator has been activated, the THV is damaged, or the expiration date has elapsed. Do not mishandle the Ascendra+ delivery system or use it if the packaging or any components are not sterile, have been opened or are damaged (e.g. kinked or stretched), or the expiration date has elapsed. Care should be exercised in patients with hypersensitivities to cobalt, nickel, chromium, molybdenum, titanium, manganese, silicon, and/or polymeric materials. The procedure should be conducted under fluoroscopic guidance. Some fluoroscopically guided procedures are associated with a risk of radiation injury to the skin. These injuries may be painful, disfiguring, and long-lasting. THV recipients should be maintained on anticoagulant/antiplatelet therapy, except when contraindicated, as determined by their physician. This device has not been tested for use without anticoagulation. Do not add or apply antibiotics to the storage solution, rinse solutions, or to the THV. Precautions: Long-term durability has not been established for the THV. Regular medical follow-up is advised to evaluate THV performance. Glutaraldehyde may cause irritation of the skin, eyes, nose and throat. Avoid prolonged or repeated exposure to, or breathing of, the solution. Use only with adequate ventilation. If skin contact occurs, immediately flush the affected area with water; in the event of contact with eyes, seek immediate medical attention. For more information about glutaraldehyde exposure, refer to the Material Safety Data Sheet available from Edwards Lifesciences. To maintain proper valve leaflet coaptation, do not overinflate the deployment balloon. Appropriate antibiotic prophylaxis is recommended post-procedure in patients at risk for prosthetic valve infection and endocarditis. Safety, effectiveness, and durability have not been established for valve-invalve procedures. Safety and effectiveness have not been established for patients with the following characteristics/comorbidities: Non-calcified aortic annulus, severe ventricular dysfunction with ejection fraction < 20%, congenital unicuspid or congenital bicuspid aortic valve, mixed aortic valve disease (aortic stenosis and aortic regurgitation with predominant aortic regurgitation > 3+), pre-existing prosthetic heart valve or prosthetic ring in any position, severe mitral annular calcification (MAC), severe (> 3+) mitral insufficiency, or Gorlin syndrome, blood dyscrasias defined as: leukopenia (WBC < 3000 cells/ml), acute anemia (Hb < 9 g/dl), thrombocytopenia (platelet count <50,000 cells/ml) or history of bleeding diathesis or coagulopathy, hypertrophic cardiomyopathy with or without obstruction (HOCM), echocardiographic evidence of intracardiac mass, thrombus, or vegetation, a known hypersensitivity or contraindication to aspirin, heparin, ticlopidine (Ticlid ), or clopidogrel (Plavix ), or sensitivity to contrast media, which cannot be adequately premedicated, excessive calcification of vessel at access site, bulky calcified aortic valve leaflets in close proximity to coronary ostia. Potential Adverse Events: Potential risks associated with the overall procedure including potential access complications associated with standard cardiac catheterization, balloon valvuloplasty, the potential risks of conscious sedation and/or general anesthesia, and the use of angiography: death; stroke/transient ischemic attack, clusters or neurological deficit; paralysis; permanent disability; respiratory insufficiency or respiratory failure; hemorrhage requiring transfusion or intervention; cardiovascular injury including perforation or dissection of vessels, ventricle, myocardium or valvular structures that may require intervention; pericardial effusion or cardiac tamponade; embolization including air, calcific valve material or thrombus; infection including septicemia and endocarditis; heart failure; myocardial infarction; renal insufficiency or renal failure; conduction system defect which may require a permanent pacemaker; arrhythmia; retroperitoneal bleed; AV fistula or pseudoaneurysm; reoperation; ischemia or nerve injury; restenosis; pulmonary edema; pleural effusion; bleeding; anemia; abnormal lab values (including electrolyte imbalance); hypertension or hypotension; allergic reaction to anesthesia, contrast media, or device materials; hematoma; syncope; pain or changes at the access site; exercise intolerance or weakness; inflammation; angina; heart murmur; fever. Additional potential risks associated with the use of the THV, delivery system, and/or accessories include: cardiac arrest; cardiogenic shock; emergency cardiac surgery; cardiac failure or low cardiac output; coronary flow obstruction/transvalvular flow disturbance; device thrombosis requiring intervention; valve thrombosis; device embolization; device migration or malposition requiring intervention; valve deployment in unintended location; valve stenosis; structural valve deterioration (wear, fracture, calcification, leaflet tear/tearing from the stent posts, leaflet retraction, suture line disruption of components of a prosthetic valve, thickening, stenosis); device degeneration; paravalvular or transvalvular leak; valve regurgitation; hemolysis; device explants; nonstructural dysfunction; mechanical failure of delivery system, and/or accessories; non-emergent reoperation. ASCENDRA BALLOON AORTIC VALVULOPLASTY CATHETER Indications: The Ascendra Balloon Aortic Valvuloplasty Catheter is indicated for valvuloplasty of a stenotic aortic valve prior to implantation of the Edwards SAPIEN or Edwards SAPIEN XT Transcatheter Heart Valve. Contraindications: Other than standard risks associated with insertion of a cardiovascular catheter, there are no known contraindications for valvuloplasty. The patient s medical condition could affect successful use of this catheter. Warnings: The device is designed, intended, and distributed for single use only. Do not resterilize or reuse the device. There are no data to support the sterility, nonpyrogenicity, and functionality of the device after reprocessing. Do not mishandle the device or use it if the packaging or any components are not sterile, have been opened or are damaged (e.g. kinked or stretched), or the expiration date has elapsed. Precautions: For special considerations associated with the use of this device prior to transcatheter heart valve (THV) implantation, refer to the THV instructions for use (IFU). This catheter has not been tested with any transcatheter valve other than the Edwards SAPIEN and Edwards SAPIEN XT transcatheter heart valve. Use only appropriate balloon inflation medium. Do not use air or gaseous medium to inflate the balloon. The device is not intended for post-dilation of deployed transcatheter heart valves. While exposed within the body, device advancement and retrieval should not be done without the aid of fluoroscopy. Do not advance or retract the device unless the balloon is fully deflated under vacuum. Potential Adverse Events: Complications associated with standard catheterization, balloon valvuloplasty, and the use of angiography include, but are not limited to, allergic reaction to anesthesia or to contrast media, thrombus formation, plaque dislodgement and embolization that may result in myocardial infarction, stroke, distal peripheral occlusion and/or death, arrhythmia development, cardiac perforation, conduction system injury, hematoma, infundibulum injury, annular tear or rupture and/or valve leaflet dehiscence, severe valve insufficiency, valve restenosis, valve damage, balloon rupture, balloon separation following balloon rupture, valvular tearing or trauma, thromboembolic events, and infection. Reference the Edwards SAPIEN Transcatheter Heart Valve with the Ascendra Balloon Catheter, Edwards SAPIEN Transcatheter Heart Valve with the Ascendra 3 Delivery System, or the Edwards SAPIEN XT Transcatheter Heart Valve with the Ascendra+ Delivery System Instructions for Use for a full list of potential adverse events. ASCENDRA+ INTRODUCER SHEATH SET Indications: The Ascendra+ Introducer Sheath Set is indicated for the introduction and removal of devices used with the Edwards SAPIEN XT Transcatheter Heart Valve. Contraindications: No known contraindications. Warnings: The devices are designed, intended, and distributed for single use only. Do not resterilize or reuse the devices. There are no data to support the sterility, nonpyrogenicity, and functionality of the devices after reprocessing. Do not mishandle the device or use it if the packaging or any components are not sterile, have been opened or are damaged (e.g. kinked or stretched), or the expiration date has elapsed. Should not be used in patients with left ventricular aneurysm. The Ascendra+ Introducer Sheath Set must be used with a guidewire. Precautions: No known precautions. Potential Adverse Events: Complications associated with cardiac surgical intervention and use of angiography include, but are not limited to, allergic reaction to anesthesia or to contrast media, injury including myocardial injury, thrombus formation, and plaque dislodgement which may result in myocardial infarction, arrhythmia, stroke, and/or death. Reference the Edwards SAPIEN XT Transcatheter Heart Valve with the Ascendra+ Delivery System Instructions for Use for a full list of potential adverse events. EDWARDS CRIMPER Indications: The Edwards Crimper is indicated for use in preparing the Edwards SAPIEN XT Transcatheter Heart Valve for implantation. Contraindications: No known contraindications. Warnings: The device is designed, intended, and distributed for single use only. Do not resterilize or reuse the device. There are no data to support the sterility, nonpyrogenicity, and functionality of the device after reprocessing. Do not mishandle the device. Do not use the device if the packaging or any components are not sterile, have been opened or are damaged, or the expiration date has elapsed. Precautions: For special considerations associated with the use of this device prior to THV implantation, refer to the SAPIEN XT Transcatheter Heart Valve Instructions for Use. Potential Adverse Events: No known potential adverse events. CAUTION: Federal (United States) law restricts these devices to sale by or on the order of a physician. See instructions for use for full prescribing information, including indications, contraindications, warnings, precautions and adverse events. Edwards, Edwards Lifesciences, the stylized E logo, Ascendra, Ascendra 3, Ascendra+, Edwards SAPIEN, Edwards SAPIEN XT, NovaFlex, NovaFlex+, RetroFlex, RetroFlex 3, SAPIEN and SAPIEN XT are trademarks of Edwards Lifesciences Corporation Edwards Lifesciences Corporation. All rights reserved. AR11592 Edwards Lifesciences I edwards.com Irvine, California USA

Important Safety Information

Important Safety Information Important Safety Information Edwards SAPIEN 3 Transcatheter Heart Valve with the Edwards Commander Delivery System Indications: The Edwards SAPIEN 3 transcatheter heart valve, model 9600TFX, and the Society

More information

TAVR with the SAPIEN 3 Valve. See the Clinical Difference

TAVR with the SAPIEN 3 Valve. See the Clinical Difference TAVR with the See the Clinical Difference Better Than Surgery for Intermediate-Risk Patients* 1.1 % All-cause Disabling Mortality Stroke 1.0 % Lower Than Surgery * The PARTNER II trial intermediate-risk

More information

TAVR Patient Screening & Identification Guide

TAVR Patient Screening & Identification Guide TAVR Patient Screening & Identification Guide Severe Aortic Stenosis is Life Threatening Patients may live with aortic stenosis for many years during a latent, asymptomatic period, even before symptoms

More information

What is TAVR? Transcatheter Aortic Valve Replacement

What is TAVR? Transcatheter Aortic Valve Replacement What is TAVR? Transcatheter Aortic Valve Replacement What Are Your Options for Treating Severe Aortic Stenosis? Treatment for aortic stenosis depends on how far your disease has progressed. If your stenosis

More information

TAVR with the SAPIEN 3 Valve See the Clinical Difference. Name: Title: Date:

TAVR with the SAPIEN 3 Valve See the Clinical Difference. Name: Title: Date: TAVR with the SAPIEN 3 Valve See the Clinical Difference Name: Title: Date: SAPIEN 3 Valve 2 1 Outer Sealing Skirt Designed to minimize paravalvular (PV) leak 3 2 Frame Design Enhanced frame geometry for

More information

Transcatheter Heart Valve. Replacement. With the Edwards SAPIEN 3. for Patients & Caregivers

Transcatheter Heart Valve. Replacement. With the Edwards SAPIEN 3. for Patients & Caregivers For Patients With a Failing Surgical Bioprosthetic Heart Valve Transcatheter Heart Valve Replacement With the Edwards SAPIEN 3 Transcatheter Heart Valve for Patients & Caregivers This patient booklet is

More information

Transcatheter Aortic Valve Replacement

Transcatheter Aortic Valve Replacement INTERMEDIATE OR GREATER RISK Transcatheter Aortic Valve Replacement with the Edwards SAPIEN 3 Transcatheter Heart Valve For Patients & Caregivers This patient booklet is for those who are suffering from

More information

2018 Facility and Physician Billing Guide

2018 Facility and Physician Billing Guide 2018 Facility and Physician Billing Guide Transcatheter Heart Valve Replacement Technologies Physician Inpatient Coding for TAVR Facilities and Physicians use Current Procedural Terminology (CPT 1 ) codes

More information

Pre-procedural CT angiography for Transcatheter Aortic Valve Implantation: What a Radiologist Needs to Know?

Pre-procedural CT angiography for Transcatheter Aortic Valve Implantation: What a Radiologist Needs to Know? Pre-procedural CT angiography for Transcatheter Aortic Valve Implantation: What a Radiologist Needs to Know? E O Dwyer, C O Brien, I Murphy, C Shortt, O Buckley Department of Radiology, AMNCH, Dublin,

More information

Transcatheter Aortic Valve Replacement

Transcatheter Aortic Valve Replacement I N T E R M E D I AT E O R G R E AT E R R I S K Transcatheter Aortic Valve Replacement With the Edwards SAPIEN 3 Transcatheter Heart Valve For Patients & Caregivers This patient booklet is for those who

More information

Australia and New Zealand Source Registry Edwards Sapien Aortic Valve 30 day Outcomes

Australia and New Zealand Source Registry Edwards Sapien Aortic Valve 30 day Outcomes Australia and New Zealand Source Registry Edwards Sapien Aortic Valve 30 day Outcomes A/ Professor Darren Walters On behalf of the ANZ Source Investigators Director of Cardiology Brisbane, Australia ANZ

More information

LIFE IS DIFFERENT WITH PRO. Evolut PRO System

LIFE IS DIFFERENT WITH PRO. Evolut PRO System LIFE IS DIFFERENT WITH PRO Evolut PRO System YOUR PATIENTS DESERVE A PRO The Evolut PRO System combines exceptional valve design and advanced sealing with an excellent safety profile. BUILT ON A PROVEN

More information

Aortic Stenosis and TAVR TARUN NAGRANI, MD INTERVENTIONAL AND ENDOVASCULAR CARDIOLOGIST, SOMC

Aortic Stenosis and TAVR TARUN NAGRANI, MD INTERVENTIONAL AND ENDOVASCULAR CARDIOLOGIST, SOMC Aortic Stenosis and TAVR TARUN NAGRANI, MD INTERVENTIONAL AND ENDOVASCULAR CARDIOLOGIST, SOMC No Financial Disclosures Aortic Stenosis AS is an insidious disease with a long latency period followed by

More information

DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service

DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service M AY. 6. 2011 10:37 A M F D A - C D R H - O D E - P M O N O. 4147 P. 1 DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service Food and Drug Administration 10903 New Hampshire Avenue Document Control

More information

2/28/2010. Speakers s name: Paul Chiam. I have the following potential conflicts of interest to report: NONE. Antegrade transvenous transseptal route

2/28/2010. Speakers s name: Paul Chiam. I have the following potential conflicts of interest to report: NONE. Antegrade transvenous transseptal route Transcatheter Aortic Valve Implantation Asian perspective Speakers s name: Paul Chiam Paul TL Chiam MBBS, MRCP, FACC I have the following potential conflicts of interest to report: NONE Consultant National

More information

Transcatheter Pulmonary Valve Therapy

Transcatheter Pulmonary Valve Therapy Transcatheter Pulmonary Valve Therapy With the Edwards SAPIEN XT Transcatheter Heart Valve For Patients and Caregivers This booklet was created to help you learn more about the Edwards SAPIEN XT Transcatheter

More information

New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor. Cardiothoracic Radiology

New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor. Cardiothoracic Radiology New Cardiovascular Devices and Interventions: Non-Contrast MRI for TAVR Abhishek Chaturvedi Assistant Professor Cardiothoracic Radiology Disclosure I have no disclosure pertinent to this presentation.

More information

REBEL. Platinum Chromium Coronary Stent System. Patient Information Guide

REBEL. Platinum Chromium Coronary Stent System. Patient Information Guide REBEL Patient Information Guide REBEL PATIENT INFORMATION GUIDE You have recently had a REBEL bare metal stent implanted in the coronary arteries of your heart. The following information is important for

More information

Transforming the Treatment of Aortic Valve Disease

Transforming the Treatment of Aortic Valve Disease Transforming the Treatment of Aortic Valve Disease How Do Your Heart Valves Work? Pulmonary Valve Has three leaflets. It controls blood flow from the right ventricle to the pulmonary artery, sending blood

More information

CIPG Transcatheter Aortic Valve Replacement- When Is Less, More?

CIPG Transcatheter Aortic Valve Replacement- When Is Less, More? CIPG 2013 Transcatheter Aortic Valve Replacement- When Is Less, More? James D. Rossen, M.D. Professor of Medicine and Neurosurgery Director, Cardiac Catheterization Laboratory and Interventional Cardiology

More information

The Role of Imaging in Transcatheter Aortic Valve Implantation

The Role of Imaging in Transcatheter Aortic Valve Implantation The Role of Imaging in Transcatheter Aortic Valve Implantation Helmut Baumgartner Westfälische Wilhelms-Universität Münster Division of Adult Congenital and Valvular Heart Disease Department of Cardiovascular

More information

Dr Winnie Sze-Wun Chan. Cardiac Team Deputy Team Head Department of Radiology and Imaging Queen Elizabeth Hospital Hong Kong

Dr Winnie Sze-Wun Chan. Cardiac Team Deputy Team Head Department of Radiology and Imaging Queen Elizabeth Hospital Hong Kong Dr Winnie Sze-Wun Chan Cardiac Team Deputy Team Head Department of Radiology and Imaging Queen Elizabeth Hospital Hong Kong Why? Is CT reliable? How to perform the CT study? How to interpret the CT study?

More information

What You Need to Know About Aortic Stenosis

What You Need to Know About Aortic Stenosis What You Need to Know About Aortic Stenosis Millions of people in the United States have aortic stenosis, yet many people have never heard of it. As a caregiver, you may be asked to help navigate the road

More information

Preprocedural evaluation for TAVR

Preprocedural evaluation for TAVR KEBE 30/05/15 Preprocedural evaluation for TAVR Ioannis Iakovou, MD, PhD Interventional Cardiology Onassis Cardiac Surgery Center Athens, Greece Clinical Pathway: Developing Peri- Procedural Protocols

More information

Transcatheter Aortic Valve Replacement: Current and Future Devices: How do They Work, Eligibility, Review of Data

Transcatheter Aortic Valve Replacement: Current and Future Devices: How do They Work, Eligibility, Review of Data Transcatheter Aortic Valve Replacement: Current and Future Devices: How do They Work, Eligibility, Review of Data Echo Florida 2013 Jonathan J. Passeri, M.D. Co-Director, Heart Valve Program Director,

More information

An Update on the Edwards TAVR Results. Zvonimir Krajcer, MD Director, Peripheral Intervention Texas Heart Institute at St.

An Update on the Edwards TAVR Results. Zvonimir Krajcer, MD Director, Peripheral Intervention Texas Heart Institute at St. An Update on the Edwards TAVR Results Zvonimir Krajcer, MD Director, Peripheral Intervention Texas Heart Institute at St. Luke s Hospital Disclosures On the speaker s bureau for Endologix, TriVascular,

More information

Optimal Imaging Technique Prior to TAVI -Echocardiography-

Optimal Imaging Technique Prior to TAVI -Echocardiography- 2014 KSC meeting Optimal Imaging Technique Prior to TAVI -Echocardiography- Geu-Ru Hong, M.D. Ph D Associate Professor of Medicine Division of Cardiology, Severance Cardiovascular Hospital Yonsei University

More information

Transcatheter Aortic Valve Implantation Management of risks and complications

Transcatheter Aortic Valve Implantation Management of risks and complications Transcatheter Aortic Valve Implantation Management of risks and complications TAVI Summit, Seoul, Korea, Spetember 3rd, 2011 Alain Cribier University of Rouen, France Complications of TAVI Depending on

More information

Severity of AS Degree of AV calcification (? Bicuspid AV), annulus size, & aortic root

Severity of AS Degree of AV calcification (? Bicuspid AV), annulus size, & aortic root The role of Cardiac Imaging modalities in evaluation & selection of patients for Trans-catheter Aortic Valve Implantation Dr.Saeed AL Ahmari Consultant Cardiologist Prince Sultan Cardaic Center, Riyadh

More information

TAVR SPRING 2017 The evolution of TAVR

TAVR SPRING 2017 The evolution of TAVR TAVR SPRING 2017 The evolution of TAVR Matthew Johnson, MD Disclosers None Evolution of the Balloon- Expandable Transcatheter Valves Cribier 2002 SAPIEN 2006 SAPIEN XT 2009 SAPIEN 3 2013 * Sheath compatibility

More information

Imaging in TAVI. Jeroen J Bax Dept of Cardiology Leiden Univ Medical Center The Netherlands Davos, feb 2013

Imaging in TAVI. Jeroen J Bax Dept of Cardiology Leiden Univ Medical Center The Netherlands Davos, feb 2013 Imaging in TAVI Jeroen J Bax Dept of Cardiology Leiden Univ Medical Center The Netherlands Davos, feb 2013 Research grants: Medtronic, Biotronik, Boston Scientific, St Jude, BMS imaging, GE Healthcare,

More information

Edwards SAPIEN 3 Kit - Transapical and Transaortic

Edwards SAPIEN 3 Kit - Transapical and Transaortic The THV is recommended to be implanted in a native annulus size range associated with the three-dimensional area of the aortic annulus measured at the basal ring during systole: Edwards SAPIEN 3 Kit -

More information

TAVR: Echo Measurements Pre, Post And Intra Procedure

TAVR: Echo Measurements Pre, Post And Intra Procedure 2017 ASE Florida, Orlando, FL October 10, 2017 8:00 8:25 AM 25 min TAVR: Echo Measurements Pre, Post And Intra Procedure Muhamed Sarić MD, PhD, MPA Director of Noninvasive Cardiology Echo Lab Associate

More information

Talent Abdominal Stent Graft

Talent Abdominal Stent Graft Talent Abdominal with THE Xcelerant Hydro Delivery System Expanding the Indications for EVAR Treat More Patients Short Necks The Talent Abdominal is the only FDA-approved device for proximal aortic neck

More information

PATIENT BOOKLET MEDTRONIC SURGICAL VALVE REPLACEMENT. Tissue Valve for Aortic and Mitral Valve Replacement

PATIENT BOOKLET MEDTRONIC SURGICAL VALVE REPLACEMENT. Tissue Valve for Aortic and Mitral Valve Replacement PATIENT BOOKLET MEDTRONIC SURGICAL VALVE REPLACEMENT Tissue Valve for Aortic and Mitral Valve Replacement ARE MEDTRONIC SURGICAL TISSUE HEART VALVES RIGHT FOR YOU? Medtronic surgical heart valves are for

More information

Interventional procedures guidance Published: 26 September 2014 nice.org.uk/guidance/ipg504

Interventional procedures guidance Published: 26 September 2014 nice.org.uk/guidance/ipg504 Transcatheter valve-in-valve e implantation for aortic bioprosthetic valve dysfunction Interventional procedures guidance Published: 26 September 2014 nice.org.uk/guidance/ipg504 Your responsibility This

More information

EVOLUT R FORWARD 30-DAY OUTCOMES PRESENTED AT THE TCT ANNUAL MEETING OCTOBER 31, 2016

EVOLUT R FORWARD 30-DAY OUTCOMES PRESENTED AT THE TCT ANNUAL MEETING OCTOBER 31, 2016 EVOLUT R FORWARD 30-DAY OUTCOMES PRESENTED AT THE TCT ANNUAL MEETING OCTOBER 31, 2016 OBJECTIVE/PRIMARY ENDPOINT FORWARD is a multicenter, prospective, single-arm, observational post-market study to evaluate

More information

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use

The SplitWire Percutaneous Transluminal Angioplasty Scoring Device. Instructions for Use The SplitWire Percutaneous Transluminal Angioplasty Scoring Device Instructions for Use Contents Contains one (1) SplitWire device. Sterile. Sterilized with ethylene oxide gas. Radiopaque. For single use

More information

Edwards Sapien. Medtronic CoreValve. Inoperable FDA approved High risk: in trials. FDA approved

Edwards Sapien. Medtronic CoreValve. Inoperable FDA approved High risk: in trials. FDA approved Transcatheter Aortic Valve Replacement Symptomatic Aortic Stenosis Asymptomatic Juan Crestanello, MD Interim Director, Division of Cardiac Surgery Associate Professor Division of Cardiac Surgery The Ohio

More information

16 YEAR RESULTS Carpentier-Edwards PERIMOUNT Mitral Pericardial Bioprosthesis, Model 6900

16 YEAR RESULTS Carpentier-Edwards PERIMOUNT Mitral Pericardial Bioprosthesis, Model 6900 CLINICAL COMMUNIQUé 6 YEAR RESULTS Carpentier-Edwards PERIMOUNT Mitral Pericardial Bioprosthesis, Model 69 The Carpentier-Edwards PERIMOUNT Mitral Pericardial Valve, Model 69, was introduced into clinical

More information

Echo Assessment Pre-TAVI

Echo Assessment Pre-TAVI Disclosure Statement of Financial Interest Within the past 12 months, I or my spouse/partner have had a financial Interest /arrangement or affiliation with the organization(s) listed below Echocardiographic

More information

1-YEAR OUTCOMES FROM JOHN WEBB, MD

1-YEAR OUTCOMES FROM JOHN WEBB, MD 1-YEAR OUTCOMES FROM JOHN WEBB, MD ON BEHALF OF THE SAPIEN 3 INVESTIGATORS UNIVERSITY OF BRITISH COLUMBIA VANCOUVER, CANADA Potential conflicts of interest Speaker's name: John Webb I have the following

More information

Successful Transfemoral Edwards Sapien Aortic. Valve Implantation in a Patient with Previous. Mitral Valve Replacement

Successful Transfemoral Edwards Sapien Aortic. Valve Implantation in a Patient with Previous. Mitral Valve Replacement Advanced Studies in Medical Sciences, Vol. 2, 2014, no. 1, 37-45 HIKARI Ltd, www.m-hikari.com http://dx.doi.org/10.12988/asms.2014.31213 Successful Transfemoral Edwards Sapien Aortic Valve Implantation

More information

TAVR : Caring for your patients before and after TAVR

TAVR : Caring for your patients before and after TAVR TAVR : Caring for your patients before and after TAVR Zubair Ahmed MD FSCAI Interventional Cardiologist Washington Regional Medical Center / Walker Heart Institute What is Aortic Valve Stenosis? AVA ~4

More information

Aortic Valve Practice Guidelines: What Has Changed and What You Need to Know

Aortic Valve Practice Guidelines: What Has Changed and What You Need to Know Aortic Valve Practice Guidelines: What Has Changed and What You Need to Know James F. Burke, MD Program Director Cardiovascular Disease Fellowship Lankenau Medical Center Disclosure Dr. Burke has no conflicts

More information

PATIENT BOOKLET. Medtronic Transcatheter Aortic Valve Replacement (TAVR) System. medtronic.com/tavr

PATIENT BOOKLET. Medtronic Transcatheter Aortic Valve Replacement (TAVR) System. medtronic.com/tavr PATIENT BOOKLET Medtronic Transcatheter Aortic Valve Replacement (TAVR) System medtronic.com/tavr IS THE MEDTRONIC TAVR VALVE RIGHT FOR YOU? The Medtronic TAVR valve is for people with severe aortic stenosis

More information

Establishing the New Standard of Care for Inoperable Aortic Stenosis THE PARTNER TRIAL COHORT B RESULTS

Establishing the New Standard of Care for Inoperable Aortic Stenosis THE PARTNER TRIAL COHORT B RESULTS Establishing the New Standard of Care for Inoperable Aortic Stenosis THE PARTNER TRIAL COHORT B RESULTS E D W A R D S T R A N S C A T H E T E R H E A R T V A L V E P R O G R A M T H E P A R T N E R T R

More information

Jonathon Leipsic MD FRCPC FSCCT. Vice Chairman of Radiology University of British Columbia. Disclosures

Jonathon Leipsic MD FRCPC FSCCT. Vice Chairman of Radiology University of British Columbia. Disclosures Jonathon Leipsic MD FRCPC FSCCT Vice Chairman of Radiology University of British Columbia Disclosures Speaker s bureau: GE Healthcare and Edwards LifeSciences Grant Support- CIHR, GE Healthcare Advisory

More information

Image Assistance in TAVI Why CT? Won-Jang Kim, MD, PhD Clinical Assistant Professor of Medicine, Heart Institute, Asan Medical Center, Seoul, Korea

Image Assistance in TAVI Why CT? Won-Jang Kim, MD, PhD Clinical Assistant Professor of Medicine, Heart Institute, Asan Medical Center, Seoul, Korea Image Assistance in TAVI Why CT? Won-Jang Kim, MD, PhD Clinical Assistant Professor of Medicine, Heart Institute, Asan Medical Center, Seoul, Korea Major Uses of CT in TAVI Ileofemoral Patient Arterial

More information

Assurant Cobalt Iliac BALLOON EXPANDABLE STENT SYSTEM

Assurant Cobalt Iliac BALLOON EXPANDABLE STENT SYSTEM Assurant Cobalt Iliac BALLOON EXPANDABLE STENT SYSTEM Innovating for life. CONFORMABILIT Y 6 F S H E AT H C O M PAT I B I L I T Y THE ASSURANT COBALT ILIAC STENT, WITH ITS UNIQUE COBALT CHROMIUM MODULAR

More information

Boston, MA 2 Service Chief, Cardiovascular Imaging, Department of Radiology, Massachusetts General Hospital,

Boston, MA 2 Service Chief, Cardiovascular Imaging, Department of Radiology, Massachusetts General Hospital, Chapter 9: Cardiac imaging for TAVR: CTA, TTE, TEE, and valve sizing Lucy M. Safi, DO 1 ; Brian Ghoshhajra, MD, MBA 2 ; Jonathan J. Passeri, MD 3 1 Clinical and Research Fellow in Medicine, Massachusetts

More information

Update on Percutaneous Therapies for Structural Heart Disease. William Thomas MD Director of Structural Heart Program Tucson Medical Center

Update on Percutaneous Therapies for Structural Heart Disease. William Thomas MD Director of Structural Heart Program Tucson Medical Center Update on Percutaneous Therapies for Structural Heart Disease William Thomas MD Director of Structural Heart Program Tucson Medical Center NCVH 2014- Tucson Disclosure of Financial Interest Research: Stock

More information

TRANSAPICAL AORTIC VALVE REPAIR

TRANSAPICAL AORTIC VALVE REPAIR TRANSAPICAL AORTIC VALVE REPAIR Mauro ROMANO M.D. Department of Cardio-Vascular Surgery Institut Cardiovasculaire Paris Sud Institut Hospitalier Jacques Cartier MASSY FRANCE romano.mauro@orange.fr Treatment

More information

0 P a g e NEIL E STRICKMAN MD

0 P a g e NEIL E STRICKMAN MD 0 P a g e NEIL E STRICKMAN MD T ranscatheter Aortic Valve Replacement INTRODUCTION The heart is a muscular organ located in your chest between your lungs which is designed to pump blood throughout the

More information

PROVEN PLUS. Introducing the Avalus Aortic Valve by Medtronic.

PROVEN PLUS. Introducing the Avalus Aortic Valve by Medtronic. PROVEN PLUS. Introducing the Avalus Aortic Valve by Medtronic. With more than 40 years of heart valve innovations, we took proven valve design concepts and adapted them for excellent implantability for

More information

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER

1 Description. 2 Indications. 3 Warnings ASPIRATION CATHETER Page 1 of 5 ASPIRATION CATHETER Carefully read all instructions prior to use, observe all warnings and precautions noted throughout these instructions. Failure to do so may result in complications. STERILE.

More information

(EU), FACC (USA), FSCAI (USA)

(EU), FACC (USA), FSCAI (USA) How to reduce vascular complications of TAVI Paul TL Chiam MBBS (S pore), MMed, MRCP (UK), FAMS FRCP (Edin), FESC (EU), FACC (USA), FSCAI (USA) Cardiologist Mount Elizabeth Hospital Singapore Definition

More information

ER REBOA Catheter. Instructions for Use

ER REBOA Catheter. Instructions for Use ER REBOA Catheter Instructions for Use Prytime Medical Devices, Inc. 229 N. Main Street Boerne, TX 78006, USA feedback@prytimemedical.com www.prytimemedical.com US 1 210 340 0116 U.S. and Foreign Patents

More information

Procedural Guidance of TAVR: How to Assure it Goes Right and What to Do If It Doesn t

Procedural Guidance of TAVR: How to Assure it Goes Right and What to Do If It Doesn t Procedural Guidance of TAVR: How to Assure it Goes Right and What to Do If It Doesn t James D. Thomas, M.D., F.A.C.C. Department of Cardiovascular Medicine Heart and Vascular Institute Cleveland Clinic

More information

1 Comparison of Warfarin and Aspirin for Symptomatic Intracranial Arterial Stenosis. N Engl J Med 352;13, March 31, 2005

1 Comparison of Warfarin and Aspirin for Symptomatic Intracranial Arterial Stenosis. N Engl J Med 352;13, March 31, 2005 The risk of ischemic stroke in patients with Intracranial Atherosclerotic Disease (ICAD) ranges from 7 to 24%. 1,2 Developed specifically for the treatment of ICAD, the Wingspan Stent System and Gateway

More information

Minimalist Transcatheter Aortic Valve Replacement (MA-TAVR)

Minimalist Transcatheter Aortic Valve Replacement (MA-TAVR) Minimalist Transcatheter Aortic Valve Replacement (MA-TAVR) Jensen HA, Condado JF, Devireddy C, Binongo JN, Leshnower BG, Babaliaros V, Sarin EL, Lerakis S, Guyton RA, Stewart JP, Syed AQ, Mavromatis K,

More information

Section 1: Initial Evaluation for Valvular Heart Disease Table 1: Initial Evaluation of an Asymptomatic Patient

Section 1: Initial Evaluation for Valvular Heart Disease Table 1: Initial Evaluation of an Asymptomatic Patient Section 1: Initial Evaluation for Valvular Heart Disease Table 1: Initial Evaluation of an Asymptomatic Patient Indication 1. Unexplained murmur or abnormal heart sounds 2. Reasonable suspicion of valvular

More information

Echocardiography as a diagnostic and management tool in medical emergencies

Echocardiography as a diagnostic and management tool in medical emergencies Echocardiography as a diagnostic and management tool in medical emergencies Frank van der Heusen MD Department of Anesthesia and perioperative Care UCSF Medical Center Objective of this presentation Indications

More information

Valve Replacement without a Scalpel Transcatheter Aortic Valve Replacement (TAVR) Charles T. Klodell, M.D.

Valve Replacement without a Scalpel Transcatheter Aortic Valve Replacement (TAVR) Charles T. Klodell, M.D. Valve Replacement without a Scalpel Transcatheter Aortic Valve Replacement (TAVR) Charles T. Klodell, M.D. Professor, Thoracic and Cardiovascular Surgery University of Florida klodell@surgery.ufl.edu Disclosures

More information

The Transcatheter Aortic Valve Replacement (TAVR)Program at Southcoast Health. Adam J. Saltzman, MD Cardiovascular Care Center

The Transcatheter Aortic Valve Replacement (TAVR)Program at Southcoast Health. Adam J. Saltzman, MD Cardiovascular Care Center The Transcatheter Aortic Valve Replacement (TAVR)Program at Southcoast Health Adam J. Saltzman, MD Cardiovascular Care Center Southcoast Health Disclosures Edwards Lifesciences: speaking honorarium Outline

More information

Structural Heart Disease Transcatheter Aortic Valve Replacement (TAVR)

Structural Heart Disease Transcatheter Aortic Valve Replacement (TAVR) Structural Heart Disease Transcatheter Aortic Valve Replacement (TAVR) Kathleen Harper DO FACC FACP 87 Chief, Cardiology Section VA Maine Healthcare Kathleen.Harper@va.gov Prevalence of Aortic Stenosis

More information

CoreValve in a Degenerative Surgical Valve

CoreValve in a Degenerative Surgical Valve CoreValve in a Degenerative Surgical Valve Ran Kornowski, MD, FESC, FACC Chairman Department of Cardiology Rabin Medical Center, Petach Tikva, Israel Disclosure Statement of Financial Interest I, Ran Kornowski,

More information

Detailed Order Request Checklists for Cardiology

Detailed Order Request Checklists for Cardiology Next Generation Solutions Detailed Order Request Checklists for Cardiology 8600 West Bryn Mawr Avenue South Tower Suite 800 Chicago, IL 60631 www.aimspecialtyhealth.com Appropriate.Safe.Affordable 2018

More information

CAUTION- Investigational device. Limited by United States law to investigational use.

CAUTION- Investigational device. Limited by United States law to investigational use. CAUTION- Investigational device. Limited by United States law to investigational use. This booklet is provided to help you learn more about the Medtronic CoreValve U.S. Pivotal Trial. The purpose of the

More information

Transcatheter Aortic Valve Replacement (TAVR)

Transcatheter Aortic Valve Replacement (TAVR) UW MEDICINE PATIENT EDUCATION Transcatheter Aortic Valve Replacement (TAVR) Treatment for aortic stenosis This handout explains when your doctor may advise TAVR to treat aortic stenosis. It includes the

More information

Aortic Valve Stenosis and TAVR: Putting it all together.

Aortic Valve Stenosis and TAVR: Putting it all together. Aortic Valve Stenosis and TAVR: Putting it all together. Maria L. Held, MSN CNS Valve Clinic Coordinator at The Cleveland Clinic Alliance of Cardiovascular Professionals April 14 th, 2018 Brief Anatomy

More information

Andrzej Ochala, MD Medical University of Silesia, Katowice, Poland

Andrzej Ochala, MD Medical University of Silesia, Katowice, Poland Andrzej Ochala, MD Medical University of Silesia, Katowice, Poland Bicuspid aortic valve o Most common congenital heart disease in adults (1% - 2%) o AS is the most common complication of BAV o Patophysiology

More information

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER

NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER Page 1 of 5 NON-COMPLIANT PTCA RAPID EXCHANGE DILATATION CATHETER STERILE. SINGLE USE ONLY. Sterilized with ethylene oxide gas. Non pyrogenic. Do not resterilize. Do not use opened or damaged packages.

More information

Incorporating the intermediate risk in Transcatheter Aortic Valve Implantation (TAVI)

Incorporating the intermediate risk in Transcatheter Aortic Valve Implantation (TAVI) Incorporating the intermediate risk in Transcatheter Aortic Valve Implantation (TAVI) Larry S. Dean, MD, MSCAI Past President SCAI Professor of Medicine and Surgery University of Washington School of Medicine

More information

Prince Sultan Cardiac Center Experience Riyadh, Saudi Arabia

Prince Sultan Cardiac Center Experience Riyadh, Saudi Arabia Transcatheter Transapical Aortic Valve Implantation Prince Sultan Cardiac Center Experience Riyadh, Saudi Arabia Ahmed Elwatidy, MD,PhD, FRCS S Kassab, MD,S Ahmari, MD, H Amri, MD, H Ismail, MD, A Calafiori,

More information

Percutaneous Mitral Valve Repair. Transesophageal Echo Acquisition Guide

Percutaneous Mitral Valve Repair. Transesophageal Echo Acquisition Guide TEE Screening MitraClip Percutaneous Mitral Valve Repair Transesophageal Echo Acquisition Guide Suggested Settings n Each view should be performed with and without color flow Doppler using color compare

More information

DURABLE. CONSISTENT. SAFE. IN.PACT Admiral Drug-Coated Balloon

DURABLE. CONSISTENT. SAFE. IN.PACT Admiral Drug-Coated Balloon DURABLE. CONSISTENT. SAFE. Drug-Coated Balloon THE SCIENCE BEHIND THE OUTCOMES DCB has proven, long-term durable outcomes across multiple clinical trials, as well as across complex patient and lesion types.

More information

INSPIRIS RESILIA Aortic Valve

INSPIRIS RESILIA Aortic Valve Aortic Valve Surgery with the INSPIRIS RESILIA Aortic Valve What You and Your Loved Ones Should Know Introduction This guide is for patients who have aortic heart valve disease and whose doctors have proposed

More information

Index. interventional.theclinics.com. Note: Page numbers of article titles are in boldface type.

Index. interventional.theclinics.com. Note: Page numbers of article titles are in boldface type. Index Note: Page numbers of article titles are in boldface type. A Ablation, of mitral leaflets, 80 Accucinch Annuloplasty system, for mitral regurgitation, 79, 94 95 Accutrak delivery system, for CoreValve

More information

Multicentre clinical study evaluating a novel resheatable self-expanding transcatheter aortic valve system

Multicentre clinical study evaluating a novel resheatable self-expanding transcatheter aortic valve system Multicentre clinical study evaluating a novel resheatable self-expanding transcatheter aortic valve system Preliminary Results: Acute and 1-year Outcomes Ganesh Manoharan, MBBCh, MD, FRCP Consultant Cardiologist

More information

Aortic valve implantation using the femoral and apical access: a single center experience.

Aortic valve implantation using the femoral and apical access: a single center experience. Aortic valve implantation using the femoral and apical access: a single center experience. R. Hoffmann, K. Brehmer, R. Koos, R. Autschbach, N. Marx, G. Dohmen Rainer Hoffmann, University Aachen, Germany

More information

SHARED DECISION MAKING: AN EVIDENCE-BASED CORNERSTONE OF LAAC THERAPY

SHARED DECISION MAKING: AN EVIDENCE-BASED CORNERSTONE OF LAAC THERAPY SHARED DECISION MAKING: AN EVIDENCE-BASED CORNERSTONE OF LAAC THERAPY SHARED DECISION MAKING: AN EVIDENCE BASED CORNERSTONE OF LAAC THERAPY Shared decision making is a collaborative process that allows

More information

TAVI- Is Stroke Risk the Achilles Heel of Percutaneous Aortic Valve Repair?

TAVI- Is Stroke Risk the Achilles Heel of Percutaneous Aortic Valve Repair? TAVI- Is Stroke Risk the Achilles Heel of Percutaneous Aortic Valve Repair? Elaine E. Tseng, MD and Marlene Grenon, MD Department of Surgery Divisions of Adult Cardiothoracic and Vascular and Endovascular

More information

Interventional procedures guidance Published: 26 July 2017 nice.org.uk/guidance/ipg586

Interventional procedures guidance Published: 26 July 2017 nice.org.uk/guidance/ipg586 Transcatheter aortic valve implantation for aortic stenosis Interventional procedures guidance Published: 26 July 17 nice.org.uk/guidance/ipg586 Your responsibility This guidance represents the view of

More information

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter

Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter Instructions for Use Reprocessed LASSO Circular Mapping Diagnostic Electrophysiology (EP) Catheter Caution: Federal (USA) law restricts this device to sale by or on the order of a physician. DEVICE DESCRIPTION

More information

PVL Assessment. Is paravalvular regurgitation after TAVR still an important consideration in 2018?

PVL Assessment. Is paravalvular regurgitation after TAVR still an important consideration in 2018? Joint Meeting 1 Aortic and Mitral Club Chairpersons: S.Adamopoulos, M. Vavuranakis, L. Michalis, P. Nihoyannopoulos PVL Assessment. Is paravalvular regurgitation after TAVR still an important consideration

More information

Nouvelles indications/ Nouvelles valves

Nouvelles indications/ Nouvelles valves Nouvelles indications/ Nouvelles valves Sadra Lotus Valve system Boston Scientific A. Tirouvanziam Institut Thorax Nantes SH-31314-AC Sept 2012 Slide 1 of 53 SH-31314-AC Sept 2012 Slide 2 of 53 Building

More information

Chapter 24: Diagnostic workup and evaluation: eligibility, risk assessment, FDA guidelines Ashwin Nathan, MD, Saif Anwaruddin, MD, FACC Penn Medicine

Chapter 24: Diagnostic workup and evaluation: eligibility, risk assessment, FDA guidelines Ashwin Nathan, MD, Saif Anwaruddin, MD, FACC Penn Medicine Chapter 24: Diagnostic workup and evaluation: eligibility, risk assessment, FDA guidelines Ashwin Nathan, MD, Saif Anwaruddin, MD, FACC Penn Medicine Mitral regurgitation, regurgitant flow between the

More information

TRANSCATHETER AORTIC VALVE IMPLANTATION: PSCC EXPERIENCE DR HUSSEIN ALAMRI PSCC RIYADH

TRANSCATHETER AORTIC VALVE IMPLANTATION: PSCC EXPERIENCE DR HUSSEIN ALAMRI PSCC RIYADH TRANSCATHETER AORTIC VALVE IMPLANTATION: PSCC EXPERIENCE DR HUSSEIN ALAMRI PSCC RIYADH Available systems: Edwards (TA and TF) and Core valve. INTRODUCTION 3 4% 0f > 65 y. 30 40% of elderly denied surgery,.

More information

TSDA Boot Camp September 13-16, Introduction to Aortic Valve Surgery. George L. Hicks, Jr., MD

TSDA Boot Camp September 13-16, Introduction to Aortic Valve Surgery. George L. Hicks, Jr., MD TSDA Boot Camp September 13-16, 2018 Introduction to Aortic Valve Surgery George L. Hicks, Jr., MD Aortic Valve Pathology and Treatment Valvular Aortic Stenosis in Adults Average Course (Post mortem data)

More information

TAVR: It s a Career, Not Just a Procedure! Jeffrey A Southard, MD Cardiology May 5, 2012

TAVR: It s a Career, Not Just a Procedure! Jeffrey A Southard, MD Cardiology May 5, 2012 TAVR: It s a Career, Not Just a Procedure! Jeffrey A Southard, MD Cardiology May 5, 2012 Transcatheter Aortic Valve Replacement T- eam A- pproach to V- alve R- eplacement UCDMC Team Administration Cardiology

More information

How to manage TAVI related vascular complications. Paul TL Chiam MBBS, FRCP, FESC, FACC, FSCAI

How to manage TAVI related vascular complications. Paul TL Chiam MBBS, FRCP, FESC, FACC, FSCAI How to manage TAVI related vascular complications Paul TL Chiam MBBS, FRCP, FESC, FACC, FSCAI Definition VARC-2 consensus statement Complications caused by: Wire Catheter Anything related to vascular access

More information

How Do I Evaluate a Patient Being Considered for TAVR? Sunday, February 14, :00 11:25 PM 25 min

How Do I Evaluate a Patient Being Considered for TAVR? Sunday, February 14, :00 11:25 PM 25 min 2016 ASE State of the Art Echocardiography Course Tucson, AZ How Do I Evaluate a Patient Being Considered for TAVR? Sunday, February 14, 2016 11:00 11:25 PM 25 min 1 M U H A M E D S A R I Ć, M D, P H D

More information

22/06/2017. Oxford City. Transcatheter aortic valve replacement 2017 guidelines. 1. First time I have heard about it. 2.

22/06/2017. Oxford City. Transcatheter aortic valve replacement 2017 guidelines. 1. First time I have heard about it. 2. Oxford City Transcatheter aortic valve replacement 2017 guidelines Monday 19 th June Jim Newton Oxford Oxford University Hospitals NHS FT How familiar are you with TAVR? 1. First time I have heard about

More information

ICE: Echo Core Lab-CRF

ICE: Echo Core Lab-CRF APPENDIX 1 ICE: Echo Core Lab-CRF Study #: - Pt Initials: 1. Date of study: / / D D M M M Y Y Y Y 2. Type of Study: TTE TEE 3. Quality of Study: Poor Moderate Excellent Ejection Fraction 4. Ejection Fraction

More information

A Health Care Professional s Guide Aortic Stenosis in Seniors

A Health Care Professional s Guide Aortic Stenosis in Seniors A Health Care Professional s Guide Aortic Stenosis in Seniors With highlights from the 2014 ACC/AHA practice guidelines for valve disease Aortic stenosis (AS) is primarily caused by calcification of the

More information

AXS Catalyst Distal Access Catheter

AXS Catalyst Distal Access Catheter AXS Catalyst Distal Access Catheter Directions for Use 2 AXS Catalyst Distal Access Catheter ONLY Caution: Federal Law (USA) restricts this device to sale by or on the order of a physician. warning Contents

More information

30-Day Outcomes Following Implantation of a Repositionable Self-Expanding Aortic Bioprosthesis: First Report From the FORWARD Study

30-Day Outcomes Following Implantation of a Repositionable Self-Expanding Aortic Bioprosthesis: First Report From the FORWARD Study 30-Day Outcomes Following Implantation of a Repositionable Self-Expanding Aortic Bioprosthesis: First Report From the Study Stephan Windecker Department of Cardiology Bern University Hospital - INSELSPITAL

More information

Dr. Jean-Claude Laborde

Dr. Jean-Claude Laborde Medtronic CoreValve Experience Alternative Access (Subclavian) and Technology Evolution of the Medtronic CoreValve TAVI System Dr. Jean-Claude Laborde Glenfield Hospital, Leicester, U.K. St George Hospital,

More information