Fixed Bearing Knees Function with Wear Resistance

Size: px
Start display at page:

Download "Fixed Bearing Knees Function with Wear Resistance"

Transcription

1 Fixed Bearing Knees Function with Wear Resistance

2 Sigma Knee System Today s surgeons demand a knee system that can react to the needs of the individual patient. The Sigma Knee System brings together function with wear resistance to match the needs of a diverse patient population. Regardless of the size, shape or activity level of patients, surgeons can feel confident that with the Sigma Knee system, they can choose the procedure and implant to meet their patients demands.

3 The Sigma Fixed Bearing Knee Portfolio The Sigma Knee System offers one of today s most comprehensive, integrated knee systems. It embraces a wide variety of philosophies and surgical techniques and continues to develop with the addition of further implant options and instrumentation. Femoral Component CR CR150 CR Porocoat PS PS with Lugs Patella 1- Post (Round and Oval) 3-Post (Round and Oval) Inset Tibial Tray Polyethylene Insert Posterior Lipped (PLI) Curved (CVD) Curved Plus (CVD+) Stabilized (STB) Polished CoCr Keeled Ti Ti Porocoat

4 Sigma Fixed Bearing Knees Function with Wear Resistance Wear Resistance Function Femoral Components Rounded coronal geometry maximizes contact area while minimizing contact stresses 1 Accommodates high flexion with Sigma CR150 Highly Polished Cobalt Chrome Tibial Tray Reduces backside polyethylene wear (as compared to titanium trays) by providing a smooth surface 2 Retrieved CoCr trays show no locking mechanism erosion 3 XLK Polyethylene Moderately cross-linked to provide increased wear resistance versus standard polyethylene 4,5 Remelted to create an oxidatively stable material i2 Locking Mechanism Integrity of locking tabs maintained with anterior bumper Interference fit between the insert and the tibial tray reduces potential for micromotion

5

6 Optimal Function Sigma Femoral Components The Sigma femoral components are designed to provide optimal function for high demand patients. The main benefits of the femoral components are: Rounded Coronal Geometry By utilizing a round-on-round geometry, the system allows a larger contact area and lower contact stresses, both in neutral alignment and varus or valgus lift-off, compared to flat-on-flat designs. This optimizes the trade-off between maximal contact area and constraint of the implant. 1 Edge Loading In contrast, lift-off of the femoral component in a flatter condylar design can lead to edge loading on the opposite side. This may cause high concentrations of contact stresses on the polyethylene. High Flexion The clinically proven Sigma J-curve with extended posterior condyles provides conforming contact through 150 degrees of flexion, reducing the risk of point contact stress. J Curve for Sigma CR150 J Curve for Sigma CR At 135 degrees of flexion, the Sigma CR150 knee system provides a 31 percent increase in contact area resulting in a 19 percent decrease in contact stress compared to the Sigma CR femoral component. This helps to protect the tibial insert and reduce polyethylene wear º Min To increase congruency and conformity in high flexion, the J-curve of the Sigma CR150 is extended beyond 120 degrees. In order to achieve this, Sigma CR150 requires a posterior bone resection of an additional 2 mm when compared to the existing Sigma CR.

7

8

9 Wear Resistance Highly Polished Cobalt Chrome Tray A highly polished Cobalt Chrome (CoCr) fixed bearing tibial tray is a unique product from DePuy Orthopaedics with features not offered by any other competitor on the market. The main benefits of this tray are: Highly Polished Surface The polyethylene friendly, highly polished CoCr tray creates a smooth surface, minimizing abrasion. 2 The Ra value (a measure of surface roughness) of the CoCr tray surface has been reduced by 95 percent compared to the older Titanium tray. 2 Proven Design The CoCr tray uses the same design that was used by the original and successful P.F.C. tibial trays. It utilizes the same tray thickness, stem and keel, design as well as the same undersurface finish. In essence, the highly polished cobalt chrome tray provides a more polyethylene friendly environment than titanium with no compromise in material strength or fixation. It has been demonstrated that: Because motion between the insert and metal backing may be inevitable, the wear characteristics of the inner tray surface should be optimized to minimize debris production. 7 Polishing the tray has been shown to improve the wear characteristics of the articulation. 7

10 Wear Resistance Sigma XLK Polyethylene The main goal of cross-linking is to improve polyethylene s wear properties. Improving the wear properties of the polyethylene material is important in fixed bearing knees because of the multi-directional stress that the insert experiences. Gamma irradiation is a proven method for cross-linking the polyethylene. As the dose of gamma radiation increases, the material s wear properties also improve. 5 But higher doses of gamma irradiation have a drawback -- gamma radiation adversely affects polyethylene s mechanical properties. 8 Therefore, it is not advisable to increase the dose indiscriminately. A balance needs to exist between the amount of wear reduction that is achieved and reduction in mechanical properties. Sigma XLK finds that balance with the following characteristics: GUR 1020 Resin Sigma XLK polyethylene is made from GUR 1020 resin which has tougher mechanical properties relative to GUR Moderately cross-linked GVF 10 XLK Irradiation Dose (Mrad) DePuy Orthopaedics uses the 5 Mrads dose as it gives the desired amount of wear reduction without a significant drop in mechanical properties. Moderate cross-linking of the polymer chains provides increased resistance to the multidirectional wear generated by fixed bearing designs. 9 Oxidatively Stable Sigma XLK is remelted above the melting point of polyethylene after it is exposed to gamma radiation to make it oxidatively stable. 8 Wear Rate (mm 3 /million cycles) Bottom line: Sigma XLK is remelted to eliminate free radicals and therefore is oxidatively stable both on the shelf and in vivo. 8

11

12 Wear Resistance i2 Locking Mechanism The Sigma i2 locking mechanism plays a pivotal role in reducing the amount of micromotion between the tibial insert and the tibial tray. The two salient features of the i2 locking mechanism include: Interference Fit The size of the polyethylene insert is 150 microns bigger than the tibial tray pocket. Due to this difference in size, the insert has to squeeze inside the tray. Since the insert deforms as it goes in the tray, there is little room for it to move, thus minimizing the rotational micromotion and potential for backside polyethylene wear. 150 micron difference Integrity There is an anterior bumper on the front of the insert between the two locking tabs. This improved design removes the load from the tabs. Since the locking tabs do not experience the stress, it reduces the risk of tabs breaking over time. The bumper will also absorb most of any anteriorly directed force, minimizing the anterior/posterior micromotion and potential for backside polyethylene wear. Reduced anterior/ posterior motion due to anterior bumper

13 This construct delivers the benefits of modularity while approaching the performance of a one-piece tibial design. When compared with the older lock, the i2 lock has reduced the amount of micromotion by 85 percent. 10 In fact, 16 microns of resultant micromotion in the Sigma design is the lowest among a group of implant systems as demonstrated in mechanical testing. 11 Mean R & RT Micromotion by Manufacturer RESULTANT MOTION (MICRONS) Previous Locking System 85% Reduction 33 i2 Locking System R (MICROMETERS) PFC i2 XLK R RT PFC i2 GVF R = (AF) 2 + (ML) 2 Advance NexGen Duracon Optetrak Journey Scorpio MANUFACTURER RT (DEG)

14 Micromotion Micromotion is the motion that occurs between the polyethylene insert and the tibial tray. It s a phenomenon that has been recognized as a contributing factor to backside wear of polyethylene and is an unintended consequence of modularity in total knee implant systems. 12 Benefits of Modularity Modularity allows flexibility to customize the thickness of the polyethylene insert after the tibial tray has been fixed in the patient and exchange of polyethylene bearings without revision of the entire tibial component. 12 Disadvantages of Modularity The tray and insert interface can be a source of polyethylene wear debris. In a study by Wasielewski et al, wear on the underside of retrieved modular tibial inserts was associated with radiographic evidence of osteolysis. 13 Source and Significance of Micromotion Micromotion is typically caused by inherent design characteristics of the implant. By definition, modularity requires the two components to be of slightly different size so that they can easily be assembled. The key is to minimize this difference so as to minimize the play between the two. At the same time, it should be easy for a surgeon to assemble (and disassemble when required) the two components. Different implant designs in the marketplace have had different levels of success achieving this balance. Solution It is not possible to completely eliminate micromotion between the tibial tray and tibial insert in a modular design. Therefore the locking mechanism, material, and the surface finish of the tibial tray assume greater significance. If any amount of motion is taking place, the following is desirable: The insert locking mechanism should secure the insert and the tray with a tight fit. The surface finish of the tray should be polyethylene friendly. It should be as smooth as possible in order to minimize the friction between the metal and plastic components. The tray material should be a friendly articular surface. Key Message The undersurface of the insert is an additional source of polyethylene debris contributing to tibial metaphyseal osteolysis. To lessen polyethylene debris produced at this modular surface, the tibial implant locking mechanism should fix the insert firmly to the metal backing to decrease relative micromotion. Because motion between the insert and the metal backing may be inevitable, the wear characteristics of the inner tray surface should be optimized to minimize wear debris production at this other articulation. 13 The combination of a highly polished cobalt chrome tray, i2 locking mechanism and moderately cross-linked polyethylene has resulted in significant reduction in overall polyethylene wear in the Sigma Knee System. Tests have shown that use of these improved technologies has reduced the polyethylene wear rates in a Sigma Fixed Bearing Knee by 88 percent under standard kinematic loads and 71 percent under high kinematic loads compared to standard polyethylene and titanium trays. 14

15 Oxidative Stability Polyethylene has been successfully used in orthopaedic implants, including knee systems, for many decades. However it is also often cited as the leading cause of knee revision. 15 Oxidative Stability Oxidative Stability is defined as the material s ability to resist combining with oxygen molecules. Oxidation eventually leads to breakdown of the polyethylene material and may contribute to implant failure. Virgin polyethylene is a material not exposed to any gamma radiation and is therefore inherently oxidatively stable. However, exposure to gamma radiation is an essential step in the current manufacturing processes. Gamma radiation serves two functions: Cross-linking - Improves the wear characteristics of polyethylene 9 Sterilization - Terminal sterilization of some inserts Oxidation When polyethylene is exposed to gamma radiation, the gamma energy initially breaks either the carbon-carbon or carbon-hydrogen bonds along the polyethylene chain and forms free radicals. If the polyethylene material with free radicals is exposed to oxygen, oxygen molecules can combine with the free radicals. This can cause the long molecular chains to break, creating even more free radicals in the process. Degradation of the polymer chain continues in the presence of free radicals and oxygen molecules. Polyethylene that is not oxidatively stable has shown mid to long-term clinical mechanical failure and elevated wear rates. 16 Thus, it is of crucial importance to either: Remove free radicals from the polyethylene material Avoid exposure of polyethylene material to oxygen if free radicals are present in the material It is desirable to remove free radicals from the polyethylene because it is not possible to avoid exposure of the polyethylene insert to oxygen once placed in the body. Therefore, manufacturing techniques like remelting have been developed that allow removal of all free radicals that are generated in the process of gamma irradiation. It has been shown that cross-linking the polyethylene and then remelting above the melt point eliminates free radicals and creates an oxidatively stable polyethylene. 8

16 Technical Details Box height of Sigma PS Femoral Components Size mm Size mm Size mm Size mm Size mm Size 4N 16.7 mm Size mm Size mm 8 mm 9 mm* Sagittal Shape *10 mm for size 6 Size 6** Size 5 Size 4 Size 3/4N Size 2.5 Size mm Inner Box (Dimension Constant) Size 1.5 Coronal Shape **Not Available for TC3 Femoral Components

17 Posterior Lipped Insert (cruciate retaining only) 8, 10, 12.5, 15, 17.5, 20 (mm) Curved Plus Insert (cruciate retaining and cruciate sacrificing) 8, 10, 12.5, 15, 17.5, 20 (mm) Curved Insert (cruciate retaining only) 8, 10, 12.5, 15, 17.5, 20 (mm) Posterior Stabilized (PS) Insert (posterior stabilized only) 8, 10, 12.5, 15, 17.5, 20, 22.5, 25 (mm) All Polyethylene CVD and all Polyethylene PLI Tibia not shown; 8, 10, 12.5, 15 (mm) options available for each Size 1.5 (Curved Plus) insert only available in 8, 10, 12.5, 15, 17.5 (mm) All Polyethylene PS Tibia not shown; 8,10, 12.5, 15 (mm) options available Size 1.5 (PS) insert only available in 8, 10, 12.5, 15, 17.5 (mm) Amount of rotation allowed by each insert: Posterior Lipped (PLI) 15 Curved (CVD) 10 Curved Plus (CVD+) 20 Stabilized (STB) 8.0 Stabilized Plus (STB+) 2.0 Keel Height Size Keel Height M/L Keel mm 37 mm 2 38 mm 37 mm mm 37 mm 3 38 mm 37 mm 4 43 mm 43 mm 5 43 mm 43 mm 6 48 mm 49 mm Peripheral Lip Height (6.6 mm) M/L Tray Thickness (2.8 mm) Keel slopes 3 degrees posteriorly The poly plug at the bottom of the tibial tray adds an additional 8 mm to the keel height.

18 Sigma High Performance Instruments Function HP Instruments deliver Function with Wear Resistance through ease of use and improved alignment. Ease of use, or function, impacts all healthcare providers throughout the surgical pathway including surgeons, scrub techs and surgeon assistants by creating a straightforward and efficient procedure. Distal Femoral Resection Efficient - Engineered for fast pinning and easy removal. Adjustments designed to be easy to access and use. User-Friendly - Designed for comfortable fingertip control. Visual Cues - Line-of-site engraved marking for quick, eye-friendly visual clarity. Secure color-coded locking after adjustment. Fixed Reference Options - Anterior or Posterior referencing in one system, available in 0, 3, 5, or 7 degrees of rotation. Rotation Guides provide reference points to Whiteside s line and epicondylar axis. Optimized profile - Cutting blocks minimize soft tissue impingement, enable complete cuts, and are the same M/L width as the implant. Flexibility - Allows for easy downsizing or upsizing changes, as well as last minute +2 or -2mm adjustments.

19 Wear Resistance Wear resistance is a key factor in an implant s long-term success. It is influenced by implant alignment, which is a combination of surgical skill and precise instrumentation. Tibial Resection Stability - Blocks are designed to maximize stability against the bone, to promote a more accurate cut. Precision - Instruments provide 1 mm resection adjustment which allows for optimum gap balancing. Precise calculation sets the exact degree of slope that the surgeon desires based on leg length. Versatility - Multiple alignment checks/tools are available to aid in correct placement and resection. Tibial Preparation Precision - 1 mm cement mantle produced by instruments provides consistent implant fit. Accuracy - Tray tower is designed for drill and punch to occur at the same spot on the tibia. Rotation - Fixed Bearing instruments allow surgeons to locate optimal implant positioning for rotation.

20 References 1. P.F.C. Sigma Knee System with Rotating Platform Technical Monograph. DePuy Orthopaedics, Inc. Lit. No (Rev.1). 2. Data on File at DePuy Orthopaedics, Inc. WR# Currier, J.H., M.B. Mayor, A.S. Perry, J.C. Huot and D. Van Citters. Polished Tibial Trays in Modular Knees Show Reduced Backside Wear. Paper 165, Podium Presentation at AAOS, February 25, 2009, Las Vegas, NV. 4. McKellop, H., F.W. Shen, W. Diamaio and J.G. Lancaster. Wear of Gamma Cross-linked Polyethylene Acetabular Cups Against Roughened Femoral Balls. Clinical Orthopaedics and Related Research, 1999: McKellop, H., F.W. Shen, B. Lu, P. Campbell and R. Salovey. Development of an Extremely Wear-Resistant Ultra High Molecular Weight Polyethylene for Total Hip Replacements. Journal of Orthopaedic Research Vol. 17, No. 2, March 1999: Data on File at DePuy Orthopaedics, Inc. 7. Collier, M.B., C.A. Engh, Jr., J.P. McAuley, S.D. Ginn and G.A. Engh. Osteolysis After Total Knee Arthroplasty: Influence of Tibial Baseplate Surface Finish and Sterilization of Polyethylene Insert. The Journal of Bone and Joint Surgery Vol. 87-A, No. 12, December 2005: Collier, J.P., B.H. Currier, F.E. Kennedy, J.H. Currier, G.S. Timmins, S.K. Jackson and R.L. Brewer. Comparison of Cross-linked Polyethylene Materials for Orthopaedic Applications. Clinical Orthopaedics and Related Research No. 414, September 2003: Chiesa, R., M. Tanzi, S. Alfonsi, L. Paracchini, M. Moscatelli and A. Cigada. Enhanced Wear Performance of Highly Crosslinked UHMWPE for Artificial Joints. Journal of Biomedical Materials Research Vol. 50, No.3, June 2000: Data on File at DePuy Orthopaedics, Inc. WR# and Leisinger, S., S. Hazebrouck and D. Deffenbaugh. A New Approach to Micromotion Characterization of Modular Tibia Implants. 54th Annual Meeting of the Orthopaedic Research Society, Poster No. 1952, March 2-5, 2008, San Francisco, CA. 12. Parks, N.L., G.A. Engh, L.D.T. Topoleski and J. Emperado. Modular Tibial Insert Micromotion: A Concern with Contemporary Knee Implants. Clinical Orthopaedics and Related Research No. 356, November 1998: Wasielewski, R.C., N. Parks, I. Williams, H. Suprenant, J.P. Collier and G. Engh. Tibial Insert Undersurface as a Contributing Source of Polyethylene Wear Debris. Clinical Orthopaedics and Related Research No. 345, December 1997: Data on File at DePuy Orthopaedics, Inc. WR# and Sharkey, P., W. Hozack, R. Rothman, S. Shastri and S. Jacoby. Why are Total Knee Arthroplasties Failing Today? Clinical Orthopaedics and Related Research No. 404, November 2002: Currier, B.H., J.H. Currier, M.B. Mayor, K.A. Lyford, J.P. Collier and D.W. Van Citters. Evaluation of Oxidation and Fatigue Damage of Retrieved Crossfire Polyethylene Acetabular Cups. The Journal of Bone and Joint Surgery Vol. 89, September 2007: Printed in USA DePuy Orthopaedics, Inc. All rights reserved. 2.5M (Rev.1)

INSTRUMENTS. Design Rationale

INSTRUMENTS. Design Rationale INSTRUMENTS Design Rationale High Performance instruments that support your approach, your patient demand and your choice of knee system. Contemporary total knee arthroplasty demands high performance instrumentation

More information

INSTRUMENTS. Product Rationale

INSTRUMENTS. Product Rationale INSTRUMENTS Product Rationale R E C O V E R Y F U N C T I O N S U R V I V O R S H I P DePuy believes in an approach to knee arthroplasty that places equal importance on recovery, function and survivorship.

More information

DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0)

DePuy International Ltd St Anthony s Road Leeds LS11 8DT England Tel: +44 (0) Fax: +44 (0) This publication is not intended for distribution in the USA. DePuy Orthopaedics EMEA is a trading division of DePuy International Limited. Registered Office: St. Anthony s Road, Leeds LS11 8DT, England

More information

Rotating Platform System. Product Rationale

Rotating Platform System. Product Rationale References 1. Meftah M, Ranawat A, Ranawat C. Ten-Year Follow-up of a Rotating-Platform, Posterior-Stabilised Total Knee Arthroplasty. J Bone Joint Surg Am. 2012; 94:426-32 2. Dalury D, Gonzales R, Adams

More information

Consistency in U2 Knee System over Time

Consistency in U2 Knee System over Time U2 TM Knee System Consistency in U2 Knee System over Time Share the same femoral profile of all types allow inter-changibility Uniform AP/ML dimensions in all tibial components enhance intraoperative flexibility

More information

Instrumentation Options

Instrumentation Options Instrumentation Options With the introduction of Microplasty and Premier Instrumentation platforms and advancements such as our patented Slidex Technology, the Vanguard Complete Knee System is the surgeon

More information

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

Zimmer FuZion Instruments. Surgical Technique (Beta Version) Zimmer FuZion Surgical Technique (Beta Version) INTRO Surgical Technique Introduction Surgical goals during total knee arthroplasty (TKA) include establishment of normal leg alignment, secure implant fixation,

More information

MARATHON Cross-Linked Polyethylene

MARATHON Cross-Linked Polyethylene MARATHON Cross-Linked Polyethylene Fixation First... 1 Wear Reduction... 2 Oxidative Stability... 3 Mechanical Integrity... 4 Proven Technology...5-6 References... 7 Fixation First FIXATION FIRST Prodigy

More information

Optimum implant geometry

Optimum implant geometry Design Rationale Optimum implant geometry Extending the proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available

More information

UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD

UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS 66th Annual Meeting February 4-9, 1999 Anaheim, California COMMITTEE ON BIOMEDICAL ENGINEERING COMMITTEE ON

More information

Optimum implant geometry

Optimum implant geometry Design Rationale Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available

More information

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System

Over 20 Years of Proven Clinical Success. Zimmer Natural-Knee II System Over 20 Years of Proven Clinical Success Zimmer Natural-Knee II System CSTi Porous Coating Structurally similar to human bone CSTi porous coating combines the excellent biocompatibility of titanium with

More information

LPS SYSTEM POCKET GUIDE

LPS SYSTEM POCKET GUIDE LPS SYSTEM POCKET GUIDE Implants Procedural Uses Instruments & Trials L P S Limb Preservation System L P S Limb Preservation System The purpose of this document is to review the LPS (Limb Preservation

More information

Intramedullary Tibial Preparation

Intramedullary Tibial Preparation Surgical Technique Intramedullary Tibial Preparation Primary Total Knee Arthroplasty LEGION Total Knee System Intramedullary tibial preparation Contents Introduction...2 IM tibial highlights...3 Preoperative

More information

Extramedullary Tibial Preparation

Extramedullary Tibial Preparation Surgical Technique Extramedullary Tibial Preparation Primary Total Knee Arthroplasty LEGION Total Knee System Extramedullary tibial preparation Contents Introduction...2 EM tibial highlights...3 Preoperative

More information

TOTAL KNEE ARTHROPLASTY SYSTEM

TOTAL KNEE ARTHROPLASTY SYSTEM SURGICAL TECHNIQUE TOTAL KNEE ARTHROPLASTY SYSTEM 90-SRK-700000 B.0 0 Contents 1. Implant Sizing 2. Surgical Technique a. Incision and Exposure b. Distal Femoral Resection c. Tibial Resection d. Femoral

More information

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY Fixation First FIXATION FIRST 1958 Charnley Hip Over 1,000,000 implanted 1 96.2 percent survivorship at 32 years

More information

39 year old, 260 lb. park ranger. TKA in situ: 4 Years. First reported Metal-backed, non-modular PCA knee. 16% incidence. Modular metalbacked

39 year old, 260 lb. park ranger. TKA in situ: 4 Years. First reported Metal-backed, non-modular PCA knee. 16% incidence. Modular metalbacked Designer (Royalty income) - DePuy A Johnson & Johnson Company Consultant on Knee Products for Smith & Nephew Orthopaedics General Research Funding Inova Health System and the U.S. Army Medical Research

More information

Surgical Technique. VISIONAIRE Disposable Instruments for the LEGION Total Knee System

Surgical Technique. VISIONAIRE Disposable Instruments for the LEGION Total Knee System Surgical Technique VISIONAIRE Disposable Instruments for the LEGION Total Knee System VISIONAIRE and LEGION Disposable instrument technique* Note: All disposable instruments are interchangeable with the

More information

Vanguard Complete Knee System

Vanguard Complete Knee System Complete Knee System Design Rationale Knees Hips Extremities Cement and Accessories PMI Technology 1 One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized

More information

TOTAL KNEE ARTHROPLASTY (TKA)

TOTAL KNEE ARTHROPLASTY (TKA) TOTAL KNEE ARTHROPLASTY (TKA) 1 Anatomy, Biomechanics, and Design 2 Femur Medial and lateral condyles Convex, asymmetric Medial larger than lateral 3 Tibia Tibial plateau Medial tibial condyle: concave

More information

Product Information & Procedure Wall Chart

Product Information & Procedure Wall Chart Partial Knee System Product Information & Procedure Wall Chart Reproducible, balanced approach to partial knee replacement Developed by Dr. Gerard A. Engh Dr. Engh is renowned for his expertise in developing

More information

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique Enhanced Stability Constrained Liners Design Rationale Surgical Technique The Pinnacle Acetabular Cup System was designed to maximize the number of options available to the surgeon, and provide those options

More information

Open Access. Nick Steklov 1, Nam Chao*,2 and Sudesh Srivastav 3. LaJolla, CA, 92037, USA

Open Access. Nick Steklov 1, Nam Chao*,2 and Sudesh Srivastav 3. LaJolla, CA, 92037, USA 156 The Open Biomedical Engineering Journal, 2010, 4, 156-161 Open Access Patient-Specific Unicompartmental Knee Resurfacing Arthroplasty: Use of a Novel Interference Lock to Reduce Tibial Insert Micromotion

More information

Distal Cut First Femoral Preparation

Distal Cut First Femoral Preparation Surgical Technique Distal Cut First Femoral Preparation Primary Total Knee Arthroplasty LEGION Total Knee System Femoral preparation Contents Introduction...3 DCF femoral highlights...4 Preoperative planning...6

More information

Fixed Bearing. stabilityinmotion

Fixed Bearing. stabilityinmotion Fixed Bearing stabilityinmotion BRINGING PATENTED TECHNOLOGIES TO A SEAMLESS SYSTEM, FROM PRIMARY THROUGH TO REVISION The ATTUNE Revision Fixed Bearing Knee System is a comprehensive system that is designed

More information

Revolution. Unicompartmental Knee System

Revolution. Unicompartmental Knee System Revolution Unicompartmental Knee System While Total Knee Arthroplasty (TKA) is one of the most predictable procedures in orthopedic surgery, many patients undergoing TKA are in fact excellent candidates

More information

Luminus Flex Total Knee System (Fixed Type) The Innovative Technology for Knee Replacement

Luminus Flex Total Knee System (Fixed Type) The Innovative Technology for Knee Replacement Luminus Flex Total Knee System (Fixed Type) The Innovative Technology for Knee Replacement Intro The Luminus-Flex Total Knee system takes its name from the English word "Luminous" An adjective meaning

More information

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments Resection Guide System SURGICAL TECHNIQUE RESECTION GUIDE SURGICAL TECHNIQUE The following steps are an addendum to the SIGMA

More information

Comprehensive Solutions

Comprehensive Solutions Comprehensive Solutions Supporting healthcare professionals Flexibility Today s knee implant patients present increasingly diverse scenarios. The versatility of the JOURNEY II Total allows surgeons to

More information

PIN GUIDE SYSTEM SURGICAL TECHNIQUE. with the SIGMA High Performance Instruments System. This publication is not intended for distribution in the USA.

PIN GUIDE SYSTEM SURGICAL TECHNIQUE. with the SIGMA High Performance Instruments System. This publication is not intended for distribution in the USA. PIN GUIDE SYSTEM with the SIGMA High Performance Instruments System This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE Pin Guide Surgical Technique The following steps are

More information

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574) References 1. Sanchez-Sotelo J, Haidukewych GJ, Boberg CJ. Hospital Cost of Dislocation After Primary Total Hip Arthroplasty. J Bone Joint Surg. 2006;88A:290-294. 2. Brodner W, Grübl A, Jankovsky R, Meisinger

More information

HIGH FLEXION IN CONTEMPORARY TOTAL KNEE DESIGN: A PRECURSOR OF UHMWPE DAMAGE? A FINITE ELEMENT STUDY

HIGH FLEXION IN CONTEMPORARY TOTAL KNEE DESIGN: A PRECURSOR OF UHMWPE DAMAGE? A FINITE ELEMENT STUDY HIGH FLEXION IN CONTEMPORARY TOTAL KNEE DESIGN: A PRECURSOR OF UHMWPE DAMAGE? A FINITE ELEMENT STUDY Orthopaedic Research Laboratories Cleveland, Ohio Edward A. Morra, M.S.M.E. A. Seth Greenwald, D.Phil.(Oxon)

More information

Surgical Technique. VISIONAIRE FastPak Instruments for the LEGION Total Knee System

Surgical Technique. VISIONAIRE FastPak Instruments for the LEGION Total Knee System Surgical Technique VISIONAIRE FastPak Instruments for the LEGION Total Knee System VISIONAIRE FastPak for LEGION Instrument Technique* Nota Bene The technique description herein is made available to the

More information

Gold standard of a TKA. Conflicting goals? POLYETHYLENE WEAR THE SOLUTION: MOBILE BEARING KNEES. MOBILE BEARING A totally new approach (1977)

Gold standard of a TKA. Conflicting goals? POLYETHYLENE WEAR THE SOLUTION: MOBILE BEARING KNEES. MOBILE BEARING A totally new approach (1977) Changing designs : the case against mobile bearing? Gold standard of a TKA Goal of a TKA: 1. Pain 2. Motion 3. Longevity Stress Guy BELLIER M.D. PARIS France Conformity = Durability w/o constraints = non

More information

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique IMAGE TO COME

Zimmer NexGen MIS Tibial Component. Cemented Surgical Technique IMAGE TO COME Zimmer NexGen MIS Tibial Component Cemented Surgical Technique IMAGE TO COME Zimmer NexGen MIS Tibial Component Cemented Surgical Technique 1 Zimmer NexGen MIS Tibial Component Cemented Surgical Technique

More information

ConforMIS, Inc. 28 Crosby Drive Bedford, MA Phone: Fax:

ConforMIS, Inc. 28 Crosby Drive Bedford, MA Phone: Fax: ConforMIS, Inc. 28 Crosby Drive Bedford, MA 01730 Phone: 781.345.9001 Fax: 781.345.0147 www.conformis.com 0086 Authorized Representative: Medical Device Safety Service, GMBH Schiffgraben 41, 30175 Hannover,

More information

Evolution. Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee. Key Aspects

Evolution. Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee. Key Aspects Evolution Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee Key Aspects MicroPort s EVOLUTION Medial-Pivot Knee System was designed to recreate the natural anatomy that is lost during a total

More information

Sulzer Orthopedics Joint & Fracture Care

Sulzer Orthopedics Joint & Fracture Care Sulzer Orthopedics Joint & Fracture Care Natural-Knee Family Anatomic design for superior clinical results. Natural-Knee Natural-Knee Family: A solution for every knee. Asymmetric design increases coverage

More information

Understanding Hip Implant Options

Understanding Hip Implant Options Understanding Hip Implant Options Cup (Socket) Bearing (Liner) Head Stem (Femur) Modern Hip Implants (Ball) Metal Femoral Head on Marathon Cross-linked Polyethylene Liner Proven materials Polyethylene

More information

Triathlon Knee System

Triathlon Knee System Triathlon Knee System Express Instruments Surgical Protocol Posterior Stabilized & Cruciate Retaining TriathlonKneeSystem Express Instruments Surgical Protocol Acknowledgments..........................................................2

More information

CONTRIBUTING SURGEON. Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD

CONTRIBUTING SURGEON. Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD CONTRIBUTING SURGEON Barry Waldman, MD Director, Center for Joint Preservation and Replacement Sinai Hospital of Baltimore Baltimore, MD System Overview The EPIK Uni is designed to ease the use of the

More information

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique ESC Enhanced Stability Liners Design Rationale & Surgical Technique Choice Without Compromise DePuy Synthes PINNACLE Hip Solutions are designed with a wide range of acetabular cup options, biological and

More information

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments

TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments TRUMATCH PERSONALIZED SOLUTIONS with the SIGMA High Performance Instruments Pin Guide System SURGICAL TECHNIQUE PIN GUIDE SURGICAL TECHNIQUE The following steps are an addendum to the SIGMA High Performance

More information

ATTUNE KNEE SYSTEM: SOFCAM CONTACT

ATTUNE KNEE SYSTEM: SOFCAM CONTACT ATTUNE KNEE SYSTEM: SOFCAM CONTACT Douglas A. Dennis, MD Medical Director at Porter Center for Joint Replacement Denver, Colorado Historically, sagittal plane instability following Total Knee Arthroplasty

More information

The challenge. Knee replacement patients report lower levels of satisfaction versus hip replacement patients. Return to sports activity post surgery

The challenge. Knee replacement patients report lower levels of satisfaction versus hip replacement patients. Return to sports activity post surgery The challenge Knee replacement patients report lower levels of satisfaction versus hip replacement patients. Return to sports activity post surgery THA 52% Post-op TKA 42% Preop 36% Preop 34% Post-op Total

More information

itotal Customized POSTERIOR-STABILIZED knee replacement system

itotal Customized POSTERIOR-STABILIZED knee replacement system itotal PS Customized POSTERIOR-STABILIZED knee replacement system OUR VISION This is what we envision as the ideal total knee replacement (TKR) system: FOR THE SURGEON FOR THE PATIENT A REPRODUCIBLE PROCEDURE

More information

Persona. The Personalized Knee. Trabecular Metal Tibia. Surgical Technique

Persona. The Personalized Knee. Trabecular Metal Tibia. Surgical Technique Persona The Personalized Knee Trabecular Metal Tibia Surgical Technique Table of Contents Resect the Tibia... 4 Size and Finish the Tibia... 4 Trial Fit... 6 Component Implantation... 7 Inserter/Implant

More information

ZIMMER NEXGEN CRUCIATE RETAINING (CR) AND LEGACY KNEE POSTERIOR STABILIZED (LPS) TRABECULAR METAL MONOBLOCK TIBIAS. Surgical Technique Addendum

ZIMMER NEXGEN CRUCIATE RETAINING (CR) AND LEGACY KNEE POSTERIOR STABILIZED (LPS) TRABECULAR METAL MONOBLOCK TIBIAS. Surgical Technique Addendum ZIMMER NEXGEN CRUCIATE RETAINING (CR) AND LEGACY KNEE POSTERIOR STABILIZED (LPS) TRABECULAR METAL MONOBLOCK TIBIAS Surgical Technique Addendum SURGICAL TECHNIQUE FOR NEXGEN CRUCIATE RETAINING (CR) AND

More information

Total Knee Replacement

Total Knee Replacement Total Knee Replacement A total knee replacement, also known as total knee arthroplasty, involves removing damaged portions of the knee, and capping the bony surfaces with man-made prosthetic implants.

More information

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter Design Philosophy Cementless Stems of 12/14 Taper Stem Length Neck shaft Angle STEM-N3 STEM-N4 STEM-N5 STEM-N6 STEM-N7 STEM-N8 STEM-N9 123 mm 125 mm 130 mm 135 mm 140 mm 145 mm 150 mm 132 Cement Polished

More information

The information contained in this document is intended for healthcare professionals only.

The information contained in this document is intended for healthcare professionals only. The information contained in this document is intended for healthcare professionals only. Trident Hemispherical Acetabular Shell Trident PSL HA Acetabular Shell Featuring: The Trident Acetabular System

More information

Vanguard 360 Revision Knee System. Design Rationale

Vanguard 360 Revision Knee System. Design Rationale Vanguard 360 Revision Knee System Design Rationale One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized care to one patient. The science and art of medical

More information

Zimmer NexGen Trabecular Metal Tibial Tray

Zimmer NexGen Trabecular Metal Tibial Tray Zimmer NexGen Trabecular Metal Tibial Tray Surgical Technique Zimmer NexGen Trabecular Metal Tibial Tray Surgical Technique Give Bone A Solid Hold Zimmer NexGen Trabecular Metal Tibial Tray Surgical Technique

More information

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY

ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY E C H E L O N P R I M A R Y H I P S Y S T E M P R O D U C T R A T I O N A L E ADDRESSING CLINICAL ISSUES OF CEMENTLESS HIP ARTHROPLASTY Echelon Primary Total Hip System HIGH OFFSET STANDARD OFFSET Cementless

More information

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology Regenerex Porous Titanium Construct Knees Hips Extremities Cement and Accessories PMI Trauma Technology One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized

More information

NexGen Trabecular Metal Tibial Tray. Surgical Technique

NexGen Trabecular Metal Tibial Tray. Surgical Technique NexGen Trabecular Metal Tibial Tray Surgical Technique Table of Contents Surgical Technique...2 Resect the Tibia...2 Finish the Tibia...2 Position Based Anatomic Landmarks...3 Position Based on Trial

More information

AOX Antioxidant Polyethylene for SIGMA and LCS Rotating Platform Knee Systems

AOX Antioxidant Polyethylene for SIGMA and LCS Rotating Platform Knee Systems Value Brief AOX Antioxidant Polyethylene for SIGMA and LCS Rotating Platform Knee Systems Value Summary Advanced Technology: DePuy Orthopaedics is proud to offer AOX Antioxidant Polyethylene, the next

More information

Zimmer Segmental System

Zimmer Segmental System Zimmer Segmental System Simple solutions for solving complex salvage cases A Step Forward The Zimmer Segmental System is designed to address patients with severe bone loss associated with disease, trauma

More information

MicroSeal Total Hip Acetabular System. Like Nothing Else

MicroSeal Total Hip Acetabular System. Like Nothing Else MicroSeal Total Hip Acetabular System Like Nothing Else Like Nothing Else Unique Patented Sealing and Locking Design The MicroSeal design features: Locking/Sealing mechanisms work together to minimize

More information

MIS Cemented Tibial Component

MIS Cemented Tibial Component MIS Cemented Tibial Component NexGen Complete Knee Solution Surgical Technique Table of Contents Surgical Exposure... 2 Finish the Tibia... 2 Position Based on Anatomic Landmarks... 3 Lateral Posterior

More information

RESECTION GUIDE SYSTEM. TRUMATCH Personalized Solutions Surgical Technique with ATTUNE Knee INTUITION Instruments

RESECTION GUIDE SYSTEM. TRUMATCH Personalized Solutions Surgical Technique with ATTUNE Knee INTUITION Instruments RESECTION GUIDE SYSTEM TRUMATCH Personalized Solutions Surgical Technique with ATTUNE Knee INTUITION Instruments RESECTION GUIDE SURGICAL TECHNIQUE The following steps are an addendum to the ATTUNE Knee

More information

ATTUNE Knee System: Cruciate Sacrificing Fixed Bearing

ATTUNE Knee System: Cruciate Sacrificing Fixed Bearing ATTUNE Knee System: Cruciate Sacrificing Fixed Bearing Christel Wagner Knee Development Manager DePuy Synthes Joint Reconstruction INTRODUCTION: The purpose of a well functioning posterior cruciate ligament

More information

G7 ACETABULAR SYSTEM. beautifully. efficient.

G7 ACETABULAR SYSTEM. beautifully. efficient. G7 ACETABULAR SYSTEM beautifully efficient. HERITAGE MEETS MODERN DESIGN SIMPLICITY, EFFICIENCY AND PERFORMANCE The G7 System is a multi-bearing acetabular platform delivering simplicity, efficiency and

More information

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System Design Rationale and Surgical Technique *smith&nephew TANDEM Bipolar and Unipolar Hip System Maximizing performance from every angle Saving time in the operating room is one of the most valuable solutions

More information

Knee Replacement Implants

Knee Replacement Implants Knee Replacement Implants During knee replacement surgery, an orthopaedic surgeon will resurface your damaged knee with artificial components, called implants. There are many different types of implants.

More information

The Leader in Orthopaedic Innovation

The Leader in Orthopaedic Innovation The Leader in Orthopaedic Innovation Wright is a leading international manufacturer and distributor of superior, easy to use, and innovative orthopaedic implants and instrumentation. For over 50 years,

More information

Triathlon Knee System. Universal Baseplate Surgical Protocol

Triathlon Knee System. Universal Baseplate Surgical Protocol Triathlon Knee System Universal Baseplate Surgical Protocol Table of Contents Acknowledgments..........................................................2 Introduction...............................................................2

More information

Constrained Posterior Stabilized (CPS) Surgical Technique

Constrained Posterior Stabilized (CPS) Surgical Technique Constrained Posterior Stabilized (CPS) Surgical Technique Constrained Posterior Stabilized (CPS) Surgical Technique INTRO Introduction The Constrained Posterior Stabilized (CPS) articular surfaces can

More information

Rotating Platform. stabilityinmotion

Rotating Platform. stabilityinmotion Rotating Platform stabilityinmotion BRINGING PATENTED TECHNOLOGIES TO A SEAMLESS SYSTEM, FROM PRIMARY THROUGH REVISION The ATTUNE Revision Rotating Platform Knee System is a comprehensive system that is

More information

Triathlon Knee System Universal Baseplate Surgical Protocol

Triathlon Knee System Universal Baseplate Surgical Protocol Triathlon Knee System Universal Baseplate Surgical Protocol Triathlon Knee System Universal Baseplate Surgical Protocol Table of Contents Acknowledgments... 2 Introduction... 2 Assembly Instructions...

More information

Newer designs in Knee replacement The good,bad & ugly! Dr VAIBHAV BAGARIA

Newer designs in Knee replacement The good,bad & ugly! Dr VAIBHAV BAGARIA Newer designs in Knee replacement The good,bad & ugly! Dr VAIBHAV BAGARIA MBBS, MS, FCPS, DIP SICOT. Arthroplasty fellow- USA, Germany, Aus Joint replacement surgeon COLUMBIA ASIA HOSPITAL, GZB. Fresh

More information

Uniglide. Unicompartmental Knee Replacement Mk III surgical technique

Uniglide. Unicompartmental Knee Replacement Mk III surgical technique Uniglide Unicompartmental Knee Replacement Mk III surgical technique Uniglide Contents Operative summary 4 Pre-operative assessment 6 Preparation 7 Incision 7 Approach 7 Medial procedure 8 Tibial preparation

More information

KneeAlign System Surgical Technique Guide

KneeAlign System Surgical Technique Guide KneeAlign System Surgical Technique Guide Table of Contents Step 1 System Assembly... 1 Step 2 System Assembly... 2 Step 3 System Assembly... 2 Step 4 System Assembly... 2 Step 5 Sensor Pairing... 2 Step

More information

1Acetabular Reaming. 2Shell Sizing and Positioning. Trial Range of Motion. Trabecular Metal Natural Cup System

1Acetabular Reaming. 2Shell Sizing and Positioning. Trial Range of Motion. Trabecular Metal Natural Cup System Trabecular Metal Natural Cup System 1Acetabular Reaming Use progressively larger reamers to prepare the acetabulum. Hold the reamer steady in the same position in which the cup will be implanted (approximately

More information

Reaching new heights. Comprehensive. Efficient. Simple.

Reaching new heights. Comprehensive. Efficient. Simple. Reaching new heights Comprehensive. Efficient. Simple. Various acetabular cup choices Compatible with the different head and liner options including VERILAST Technology Reach for proven OR efficient Instrumentation

More information

ClassiQ. Scorpio. Anterior Referencing Surgical Protocol. Anterior Referencing. For use with Scorpio ClassiQ Instrument System

ClassiQ. Scorpio. Anterior Referencing Surgical Protocol. Anterior Referencing. For use with Scorpio ClassiQ Instrument System Scorpio ClassiQ Anterior Referencing Surgical Protocol For use with Scorpio ClassiQ Instrument System For use with Scorpio ClassiQ Single Radius Total Knee System AR Anterior Referencing This document

More information

INTUITION INSTRUMENTS SURGICAL TECHNIQUE

INTUITION INSTRUMENTS SURGICAL TECHNIQUE INTUITION INSTRUMENTS SURGICAL TECHNIQUE Introduction This surgical technique provides guidelines for the implantation of the ATTUNE Knee System Family of Knee Implants with the INTUITION Instrumentation.

More information

Section of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou

Section of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou Section of total knee replacement Total Knee Replacement System Knieendoprothesen System Système de prothèse totale de genou Introduction: This knee system features great versality with its modular component

More information

The power of simplicity

The power of simplicity The power of simplicity The power of simplicity Consider the facts, and take a look at the future: Revision TKA procedures are projected to double between now and 2015. 1 Restoration of a normal joint

More information

Knee Revision. Portfolio

Knee Revision. Portfolio Knee Revision Portfolio I use the DePuy Revision Knee System because of its versatility. With this system I can solve nearly any situation I encounter in the OR. Dr. Thomas Fehring, OrthoCarolina Hip and

More information

Zimmer NexGen MIS Tibial Component

Zimmer NexGen MIS Tibial Component Zimmer NexGen MIS Tibial Component Innovative Solutions for Minimally Invasive Procedures Innovative Design for MIS Procedures. The NexGen MIS Tibial Component was designed specifically to address the

More information

Constrained Posterior Stabilized (CPS)

Constrained Posterior Stabilized (CPS) Constrained Posterior Stabilized (CPS) Persona The Personalized Knee Surgical Technique Table of Contents Introduction... 2 Constraint Options Initial Knee Assessment... 3 Femoral Box Cut CPS Tibial Bearing

More information

Total Knee Original System Primary Surgical Technique

Total Knee Original System Primary Surgical Technique Surgical Procedure Total Knee Original System Primary Surgical Technique Where as a total hip replacement is primarily a bony operation, a total knee replacement is primarily a soft tissue operation. Excellent

More information

The information contained in this document is intended for healthcare professionals only.

The information contained in this document is intended for healthcare professionals only. The information contained in this document is intended for healthcare professionals only. Trident Poly Acetabular System Trident PSL HA Acetabular Shell with X3 Poly insert Trident Hemispherical Acetabular

More information

CAUTION: Ceramic liners are not approved for use in the United States.

CAUTION: Ceramic liners are not approved for use in the United States. Total Hip Prostheses, Self-Centering Hip Prostheses and Hemi-Hip Prostheses IMPORTANT: This essential product information sheet does not include all of the information necessary for selection and use of

More information

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS

SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS SURGICAL TECHNIQUE CEMENTED & PRESS-FIT UNIFIED INSTRUMENTATION INTRAOPERATIVE FLEXIBILITY PROVEN BIOMECHANICS INTRODUCTION The Summit Tapered Hip System s comprehensive set of implants and instruments

More information

Profix. Total Knee System. As described by

Profix. Total Knee System. As described by Profix Total Knee System P R I M A R Y P R O C E D U R E As described by Leo A. Whiteside, M.D. Associate Research Professor Washington University School of Medicine Director, Biomechanical Research Laboratory

More information

Pin Guide System. Surgical Technique

Pin Guide System. Surgical Technique Pin Guide System Surgical Technique Pin Guide Surgical Technique The following steps are an addendum to the SIGMA High Performance (HP) Instruments, Fixed Reference Surgical Technique (Cat. No. 0612-87-510

More information

EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE.

EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE. EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE. The year 2010 marked Exactech s silver aiversary and 25 years of mobility. As a company founded by an orthopaedic surgeon and a biomedical

More information

NATURAL MOTION TECHNOLOGY SURGICAL TECHNIQUE. EMPOWR 3D Knee. EMPOWR PS Knee

NATURAL MOTION TECHNOLOGY SURGICAL TECHNIQUE. EMPOWR 3D Knee. EMPOWR PS Knee NATURAL MOTION TECHNOLOGY EMPOWR 3D Knee EMPOWR PS Knee SURGICAL TECHNIQUE Contents System Features.... 3 Indications and Contraindications.... 4 Surgical Snap Shot.... Preoperative Planning.... Surgical

More information

INTUITION INSTRUMENTS SURGICAL TECHNIQUE

INTUITION INSTRUMENTS SURGICAL TECHNIQUE INTUITION INSTRUMENTS SURGICAL TECHNIQUE Introduction This surgical technique provides guidelines for the implantation of the ATTUNE Knee System Family of Knee Implants with the INTUITION Instrumentation.

More information

Medial Rotation Knee. Forever Active. Landmark Operative Technique Supplement: No.1 All-Polyethylene Tibia (Cemented)

Medial Rotation Knee. Forever Active. Landmark Operative Technique Supplement: No.1 All-Polyethylene Tibia (Cemented) Medial Rotation Knee Landmark Operative Technique Supplement: No.1 All-Polyethylene Tibia (Cemented) Physiological Stability and Mobility for the Active Knee Without Compromise Forever Active Contents

More information

ANATOMIC Fixed Bearing Total Knee System Posterior Stabilised Version Cemented or Cementless Options

ANATOMIC Fixed Bearing Total Knee System Posterior Stabilised Version Cemented or Cementless Options ANATOMIC Fixed Bearing Total Knee System Posterior Stabilised Version Cemented or Cementless Options ANATOMIC l Anatomic femoral component design based on a study of 420 knees digitised using the AMPLIVISION

More information

Design Rationale. ECHELON Primary Hip System

Design Rationale. ECHELON Primary Hip System Design Rationale ECHELON Primary Hip System ECHELON Primary Total Hip System Addressing clinical issues of cementless hip arthroplasty Cementless total hip arthroplasty has provided a proven method of

More information

Single Axis Revision Knee System

Single Axis Revision Knee System Orthopaedics Scorpio TS Single Axis Revision Knee System Scorpio TS Trial Cutting Guide Surgical Protocol Orthopaedics Scorpio TS Single Axis Revision Knee System Scorpio TS Trial Cutting Guide Surgical

More information

Surgical procedure. METS SMILES Total Knee Replacement

Surgical procedure. METS SMILES Total Knee Replacement Surgical procedure METS SMILES Total Knee Replacement Surgical Procedure Contents 1.0 2.0 3.0 4.0 Device information 2 3 1.1 Product overview 1.2 Indications 1.3 Absolute contra-indications 1.4 Relative

More information

The information contained in this document is intended for healthcare professionals only.

The information contained in this document is intended for healthcare professionals only. The information contained in this document is intended for healthcare professionals only. Triathlon Knee System Posterior Stabilized & Cruciate Retaining Table of Contents Acknowledgments.......................................................1

More information

OPERATIVE TECHNIQUE SKS Total Knee Replacement

OPERATIVE TECHNIQUE SKS Total Knee Replacement OPERATIVE TECHNIQUE SKS Total Knee Replacement Femoral preparation A40577 1 2 5 1: Alignment rod A30049 + A30124 2: Centromedullary rod A40224 4: T-handle A40232 6: Femoral measuring device A40411 + A40414

More information