Modularity of Orthopedic Implants
|
|
- Matilda Tate
- 6 years ago
- Views:
Transcription
1
2 STP 1301 Modularity of Orthopedic Implants Donald E. Marlowe, Jack E. Parr, and Michael B. Mayor, Editors ASTM Publication Code Number (PCN): ASTM 100 Barr Harbor Drive West Conshohocken, PA Printed in the U.S.A.
3 ISBN: ASTM Publication Code Number (PCN): Copyright AMERICAN SOCIETY FOR TESTING AND MATERIALS, West Conshohocken, PA. All rights reserved. This material may not be reproduced or copied, in whole or in part, in any printed, mechanical, electronic, film, or other distribution and storage media, without the written consent of the publisher. Photocopy Rights Authorization to photocopy items for internal, personal, or educational classroom use, or the internal, personal, or educational classroom use of specific clients, is granted by the American Society for Testing and Materials (ASTM) provided that the appropriate fee is paid to the Copyright Clearance Center, 222 Rosewood Dr., Danvers, MA 01923; Tel: ; online: ht.com/. Peer Review Policy Each paper published in this volume was evaluated by two peer reviewers and at least one editor. The authors addressed all of the reviewers' comments to the satisfaction of both the technical editor(s) and the ASTM Committee on Publications. To make technical information available as quickly as possible, the peer-reviewed papers in this publication were prepared "camera-ready" as submitted by the authors. The quality of the papers in this publication reflects not only the obvious efforts of the authors and the technical editor(s), but also the work of these peer reviewers. The ASTM Committee on Publications acknowledges with appreciation their dedication and contribution of time and effort on behalf of ASTM. Printed in Philadelphia, PA March 1997
4 Foreword This publication, Modularity of Orthopedic Implants, contains papers presented at the Symposium on Modularity of Orthopedic Implants held 8 November 1995 in Norfolk, VA. The symposium was sponsored by ASTM Committee F4 on Medical and Surgical Materials and Devices. Donald E. Marlowe, of the FDA Center for Devices and Radiological Health in Rockville, MD; Jack E. Parr, with Wright Medical Technologies in Memphis, TN; and Michael B. Mayor, with the Dartmouth Hitchcock Medical Center in Lebanon, NH, presided as symposium chairmen and are editors of the resulting publication.
5 Contents Overview CLINICAL RELEVANCE A Review of the Use of Modularity in Total Shoulder Arthroplasty JOSEPH D. ZUCKERMAN, RUSSELL J. CAVALLO, AND FREDERICK J. KUMMER ISSUES OF CONCERN The Fibrous Tissue Interface Surrounding Well-Fixed, Revised, Cementless Acetabular Components for Hip Replacement ~ STUART B. GOODMAN, PHIL HUIE, YONG SONG, MIKE O'CONNOR, STEVEN T. WOOLSON, WILLIAM J. MALONEY, DAVID J. SCHURMAN, AND RICHARD SIBLEY 21 Characterization of Solid Products of Corrosion Generated by Modular-Head Femoral Stems of Different Designs and Materials m ROBERT M. URBAN, JOSHUA J. JACOBS, JEREMY L GILBERT, STEPHEN B. RICE, MURALI JASTY, CHARLES R. BRAGDON AND JORGE O. GALANTE 33 The Mechanical and Electrochemical Processes Associated with Taper Fretting Crevice Corrosion: A Review -- JEREMY L GILBERT AND JOSHUA J. JACOBS Wear of Non-Articulating Surfaces in Modular Acetabular Cups JEFFREY J. SHEA, RICHARD D. LAMBERT, AND TERRY W. McLEAN Marking of Ceramic Femoral Heads -- BERNARD J. CALI~S STATE OF THE ART IN PROPERTIES TESTING I Test Method for Fatigue of a Modular Posterior-Stabilized Tibial Component -- MARY E. ANTHONY, MICHAEL B. COOPER, AND JEFFREY A. HOLBROOK Test Method for Evaluating Motion Between the Polymeric Articulating Surface and the Tibial Tray of Modular Total Knee Systems LYNN A. KIRKPATRICK Test Method for the Assessment of Fretting at the Femoral Head and Neck Taper Interface m TERRY W. McLEAN AND RICHARD D. LAMBERT
6 Assessing Morse Taper Function: The Relationship Between Impaction Force, Disassembly Force, and Design Variables m ANDREW H. SCHMIDT DEB A. LOCH, JOAN E. BECHTOLD, AND RICHARD F. KYLE Influence of the Ball/Stem-Interface on the Load Bearing Capability of Modular Total Hip Endoprostheses -- HERBERT G. RICHTER, GERD WILLMAN, MARTIN WIMMER, AND FRANK G. OSTHUES STATE OF THE ART IN PROPERTIES TESTING II Fatigue Integrity Test of a Modular Tibial Stem Extension MICHAEL B. COOPER, MARY E. ANTHONY, ABRAHAM B. SALEHI, AND JEFF A. HOLBROOK Fretting Corrosion Fatigue Study of Modular Joints in Total Hip Replacements by Accelerated In Vitro Testing -- SUSHIL K. BHAMBRI AND LESLIE N. GILBERTSON Corrosion Testing of Modular Hip Implants --JAY R. GOLDBERG, CHRISTINE A. BUCKLEY, JOSHUA J. JACOBS, AND JEREMY L. GILBERT Test Method Comparing Torsional Fatigue of Modular Acetabular Components m RICHARD D. LAMBERT AND TERRY W. McLEAN Effects of Neck Extension, Coverage, and Frequency on the Fretting Corrosion of Modular THR Bore and Cone Interface STANLEY A. BROWN, ALULA ABERA, MARK D'ONOFRIO, AND CURT FLEMMING The Importance of Fatigue Loading When Assessing Liner/Shell Distraction Resistance and Congruency for Modular Acetabular Components DOMINIC R. FOSCO AND DENNIS J. BUCHANAN Fretting Corrosion Mechanisms at Modular Implant Interfaces -- SHILESH C. JANI, WILLARD L. SAUER, TERRY W. McLEAN, RICHARD D. LAMBERT AND PAUL KOVACS Femoral Stem Fatigue Characteristics of Modular Hip Designs -- CHRISTINE S. HEIM, PAUL D. POSTAK, AND A. SETH GREENWALD Author Index Subject Index
7 OD Z 0! rl w L-J! FU Ln! u1
Alternative Bearing Surfaces in Total Joint Replacement
STP 1346 Alternative Bearing Surfaces in Total Joint Replacement Joshua J. Jacobs and Thomas L. Craig, Editors ASTM Stock #: STP1346 ASTM 100 Barr Harbor Drive West Conshohocken, PA 19428-2959 Printed
More informationNondestructive Testing Standards~Present and Future
STP 1151 Nondestructive Testing Standards~Present and Future Harold Berger and Leonard Mordfin, editors ASTM Publication Code Number (PCN) 04-011510-22 1916 Race Street Philadelphia, PA 19103 Library of
More informationCompression Response of Composite Structures
STP 1185 Compression Response of Composite Structures Scott E. Groves and Alton L. Highsmith, Editors ASTM Publication Code Number (PCN): 04-011850-33 1916 Race Street Philadelphia, PA 19103 Printed in
More informationCURRICULUM VITAE CHRISTINE STEUBBEN HEIM Ward Drive Chesterland, OH Telephone:
EDUCATION CURRICULUM VITAE CHRISTINE STEUBBEN HEIM 12655 Ward Drive Chesterland, OH 44026 Telephone: +440 729 9274 B.Sc. (Biomedical Engineering) Case Western Reserve University, Cleveland, Ohio (1992)
More informationThermomechanical Fatigue Behavior of Materials
STP 1186 Thermomechanical Fatigue Behavior of Materials Huseyin Sehitoglu, editor ASTM Publication Code Number (PCN) 04-011860-30 AS M 1916 Race Street Philadelphia, PA 19103 Library of Congress Cataloging-in-Publication
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 EMPIRICAL TESTING CORP. 4628 Northpark Drive Colorado Springs, CO 80918 Dawn Lissy Phone: 719 264 9937 dlissy@empiricaltesting.com MECHANICAL Valid To: January
More informationTrident Ceramic Acetabular System Technical Monograph
Trident Ceramic Acetabular System Technical Monograph Introduction Clinical research and laboratory testing have demonstrated the benefits of ceramic-on-ceramic bearings in THA. Among these benefits are
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that JTL America 3205 Clairmont Ct., Ste. B Fort
More informationEnhanced Stability Constrained Liners. Design Rationale Surgical Technique
Enhanced Stability Constrained Liners Design Rationale Surgical Technique The Pinnacle Acetabular Cup System was designed to maximize the number of options available to the surgeon, and provide those options
More informationCERTIFICATE OF ACCREDITATION
CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that JTL America 3205 Clairmont Ct., Ste. B Fort
More informationSpecializing in Mechanical Testing for Medical Devices. Office:
Specializing in Mechanical Testing for Medical Devices Office: 260.489.1444 Email: sales@jtlamerica.com www.jtlamerica.com Spine Spinal implant test standards can t keep up with the rapid pace of device
More informationHead and Neck Injuries in Sports
STP 1229 Head and Neck Injuries in Sports Earl F. Hoerner, Editor ASTM Publication Code Number (PCN): 0,t 012290-47 ASTM 1916 Race Street Philadelphia, PA 19103 Printed in the U.S.A. Library of Congress
More informationASTM Committee F04 Tuesday 05/19/2015 Grand Ballroom F Platinum 9
ASTM Committee F04 Tuesday 05/19/2015 Grand Ballroom F Platinum 9 8:00 AM 8:00 AM 10:00 AM 10:00 AM F04 Attendees are invited to an ASTM Training Session on Responsibilities for Subcommittee Chairman,
More informationSpinal Implants: Are We Evaluating Them Appropriately?
STP 1431 Spinal Implants: Are We Evaluating Them Appropriately? M. N. Melkerson, M. S.; S. L. Griffith, Ph.D.; and J. S. Kirkpatrick, M.D., editors ASTM Stock Number: STP 1431 m l ASTM International 100
More informationReaching new heights. Comprehensive. Efficient. Simple.
Reaching new heights Comprehensive. Efficient. Simple. Various acetabular cup choices Compatible with the different head and liner options including VERILAST Technology Reach for proven OR efficient Instrumentation
More informationUHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD
UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS 66th Annual Meeting February 4-9, 1999 Anaheim, California COMMITTEE ON BIOMEDICAL ENGINEERING COMMITTEE ON
More informationCLASSIFICATION OF MOBILE BEARING KNEE DESIGN: MOBILITY AND CONSTRAINT
CLASSIFICATION OF MOBILE BEAING KNEE DESIGN: MOBILITY AND CONSTAINT Orthopaedic esearch Laboratories Lutheran Hospital Cleveland Clinic Health System Christine S. Heim, B.Sc. Paul. D. Postak, B.Sc. Nicholas
More informationOptimum implant geometry
Design Rationale Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available
More informationCase report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?
Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis? Diagnosis: Ceramic head fracture In the 1970 s, Boutin implemented ceramic in modern total hip arthroplasty (THA).
More informationOptimum implant geometry
Design Rationale Optimum implant geometry Extending the proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available
More informationReCap Product Rationale
ReCap Product Rationale A Complete resurfacing system designe engineering principles, tried and tested m clinically proven fixation methods Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales
More informationICF-based Clinical Practice Guidelines for Common Musculoskeletal Conditions. Board of Directors Meeting. February 2015
ICF-based Clinical Practice Guidelines for Common Musculoskeletal Conditions Board of Directors Meeting February 2015 Submitted by: Joe Godges DPT* and Christine McDonough PT, PhD** *ICF-based Clinical
More informationScan Bi-Polar 22/28. Operative Technique
Scan Bi-Polar 22/28 Operative Technique Disclaimer This publication and all content, artwork, photographs, names, logos and marks contained in it are protected by copyright, trademarks and other intellectual
More information1.1 Ceramic on Ceramic Bearings Used with Proximal Modular Stems in THA K. J. Keggi, J. M. Keggi, R. E. Kennon and T. McTighe
1.1 Ceramic on Ceramic Bearings Used with Proximal Modular Stems in THA K. J. Keggi, J. M. Keggi, R. E. Kennon and T. McTighe Abstract Introduction: Osteolysis generated by wear debris remains a problem
More informationEnhancing stability and increasing range of motion. Metasul LDH Large Diameter Head
Enhancing stability and increasing range of motion Metasul LDH Large Diameter Head The Metasul large diameter head technology is the result of in-depth research, development and clinical experience that
More informationOptimizing function Maximizing survivorship Accelerating recovery
Surgical Technique Optimizing Function Maximizing Survivorship Accelerating Recovery The company believes in an approach to patient treatment that places equal importance on: Optimizing function Maximizing
More informationCement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter
Design Philosophy Cementless Stems of 12/14 Taper Stem Length Neck shaft Angle STEM-N3 STEM-N4 STEM-N5 STEM-N6 STEM-N7 STEM-N8 STEM-N9 123 mm 125 mm 130 mm 135 mm 140 mm 145 mm 150 mm 132 Cement Polished
More informationDAMAGE IN COMPOSITE MATERIALS: BASIC MECHANISMS, ACCUMULATION, TOLERANCE, AND CHARACTERIZATION
DAMAGE IN COMPOSITE MATERIALS: BASIC MECHANISMS, ACCUMULATION, TOLERANCE, AND CHARACTERIZATION A symposium sponsored by ASTM Committees E-7 on Nondestructive Testing and E-9 on Fatigue Bal Harbour, Fla.,
More informationRotating Platform System. Product Rationale
References 1. Meftah M, Ranawat A, Ranawat C. Ten-Year Follow-up of a Rotating-Platform, Posterior-Stabilised Total Knee Arthroplasty. J Bone Joint Surg Am. 2012; 94:426-32 2. Dalury D, Gonzales R, Adams
More informationISO INTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO 7206-2 Third edition 2011-04-01 Implants for surgery Partial and total hip joint prostheses Part 2: Articulating surfaces made of metallic, ceramic and plastics materials Implants
More informationESC. Enhanced Stability Liners. Design Rationale & Surgical Technique
ESC Enhanced Stability Liners Design Rationale & Surgical Technique Choice Without Compromise DePuy Synthes PINNACLE Hip Solutions are designed with a wide range of acetabular cup options, biological and
More informationMetaFix Cementless Total Hip Replacement Product overview
MetaFix Cementless Total Hip Replacement Product overview MetaFix Evolution Versatility Simplicity Founded on 20 years experience in cementless technology with a proven, world-leading stem design, MetaFix
More informationOperations included in the National Joint Registry (NJR) Quick links, go to: Hips > Knees > Ankles > Elbows > Shoulders > Trauma >
Operations included in the National Joint Registry (NJR) Quick links, go to: Hips > Knees > Ankles > Elbows > Shoulders > Trauma > Version 5 December 2013 1 Version control Version number Date Amendments
More informationMULTIPOLAR BIPOLAR CUP. Surgical Technique
MULTIPOLAR BIPOLAR CUP Surgical Technique MULTIPOLAR BIPOLAR CUP ASSEMBLY 1PREASSEMBLY (BACK TABLE) TECHNIQUE INSERT FEMORAL HEAD Seat the femoral head securely in the polyethylene liner. The inner split
More informationREFLECTION Constrained Liner Introduction
Surgical Technique REFLECTION Constrained Liner Introduction Surgical treatment of recurrent dislocation should be directed toward correction of any mechanical abnormalities. If dislocation is caused
More informationPublications and Presentations. B.A., Biology, University of Kansas, Lawrence, M.D., Cornell University Medical College, New York, 1979
Publications and Presentations Name: James B. Grimes, M.D. Education: B.A., Biology, University of Kansas, Lawrence, 1975 M.D., Cornell University Medical College, New York, 1979 Graduate Hospital Clinical
More informationThe power of simplicity
The power of simplicity The power of simplicity Consider the facts, and take a look at the future: Revision TKA procedures are projected to double between now and 2015. 1 Restoration of a normal joint
More informationOvation Hip System. Surgical Technique
Ovation Hip System Surgical Technique Ovation Hip System Surgical Technique Ovation Designing Surgeons: Andrew Petrella, M.D. Lecanto, FL Richard Vlasak, M.D. Gainesville, FL Ovation Tribute Designing
More informationBi-Polar 22.2mm & 28mm System - Operative technique
Disclaimer Biomet UK Ltd, as the manufacturer of this device, does not practice medicine and does not recommend any particular surgical technique for use on a specific patient. The surgeon who performs
More informationRegenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology
Regenerex Porous Titanium Construct Knees Hips Extremities Cement and Accessories PMI Trauma Technology One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized
More informationThe Leader in Orthopaedic Innovation
The Leader in Orthopaedic Innovation Wright is a leading international manufacturer and distributor of superior, easy to use, and innovative orthopaedic implants and instrumentation. For over 50 years,
More informationTrabecular Metal Primary Hip Prosthesis
Trabecular Metal Primary Hip Prosthesis Quick-Reference Guide The Best Thing Next to Bone Trabecular Metal Primary Hip Prosthesis Quick-Reference Guide Key Features & Benefits Proximal Trabecular Metal
More informationM-SERIES. Modular Femoral Stem AN ACCURATE MATCH EVERY TIME
M-SERIES Modular Femoral Stem AN ACCURATE MATCH EVERY TIME 54 Extension 114 Flexion High How do you ensure optimal post-operative joint stability? MECHANICAL RANGE OF MOTION Cup Position: 45 degrees abduction,
More informationFIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY
FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY Fixation First FIXATION FIRST 1958 Charnley Hip Over 1,000,000 implanted 1 96.2 percent survivorship at 32 years
More informationAccumulation in Liver and Spleen of Metal Particles Generated at Nonbearing Surfaces in Hip Arthroplasty
The Journal of Arthroplasty Vol. 19 No. 8 Suppl. 3 2004 Accumulation in Liver and Spleen of Metal Particles Generated at Nonbearing Surfaces in Hip Arthroplasty Robert M. Urban, AS, Michael J. Tomlinson,
More informationHOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX
HOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX HIP IMPLANTS TOTAL HIPS Ultra High Demand (metal on metal) Femur, ingrowth Femoral head, metal Acetabular shell, ingrowth Acetabular liner,
More informationProduct Rationale. Where Strength and Modularity Connect
Product Rationale Where Strength and Modularity Connect 2 ReClaim Modular Revision Hip System Advanced Strength 1 Advanced Strength Over 600 million cycles of testing 1 Advanced Fixation Advanced Instrumentation
More informationSYMPOSIUM ON MODULARITY & TAPERS IN TOTAL JOINT REPLACEMENT DEVICES. Sponsored by ASTM Committee F04 Medical & Surgical Materials & Devices
November 10, 2014 Sheraton New Orleans New Orleans, LA SYMPOSIUM ON MODULARITY & TAPERS IN TOTAL JOINT REPLACEMENT DEVICES Sponsored by ASTM Committee F04 Medical & Surgical Materials & Devices Symposium
More informationMETHODS AND MODELS FOR PREDICTING FATIGUE CRACK GROWTH UNDER RANDOM LOADING
METHODS AND MODELS FOR PREDICTING FATIGUE CRACK GROWTH UNDER RANDOM LOADING Sponsored by ASTM Subcommittee E24.06 on Fracture Mechanics Applications AMERICAN SOCIETY FOR TESTING AND MATERIALS ASTM SPECIAL
More informationRetrieval analysis of metal and ceramic femoral heads on a single CoCr stem design
Retrieval analysis of metal and ceramic femoral heads on a single CoCr stem design The Harvard community has made this article openly available. Please share how this access benefits you. Your story matters.
More informationKnee Replacement Implants
Knee Replacement Implants During knee replacement surgery, an orthopaedic surgeon will resurface your damaged knee with artificial components, called implants. There are many different types of implants.
More informationSinus Headache, Migraine, and the Otolaryngologist
Sinus Headache, Migraine, and the Otolaryngologist Mark E. Mehle Editor Sinus Headache, Migraine, and the Otolaryngologist A Comprehensive Clinical Guide 123 Editor Mark E. Mehle Private Practice ENT and
More informationPINNACLE REVISION CUP SYSTEM
PINNACLE REVISION CUP SYSTEM This publication is not intended for distribution in the USA. DESIGN RATIONALE FLEXIBILITY. PRECISION. CONFIDENCE. DePuy Synthes Joint Reconstruction is proud to offer the
More informationCORRELATING SENSORY OBJECTIVE MEASUREMENTS- NEW METHODS FOR ANSWERING OLD PROBLEMS
CORRELATING SENSORY OBJECTIVE MEASUREMENTS- NEW METHODS FOR ANSWERING OLD PROBLEMS A symposium sponsored by ASTM Committee E-18 on Sensory Evaluation of Materials and Products AMERICAN SOCIETY FOR TESTING
More informationISO INTERNATIONAL STANDARD. Non-active surgical implants Joint replacement implants Particular requirements
INTERNATIONAL STANDARD ISO 21534 Second edition 2007-10-01 Non-active surgical implants Joint replacement implants Particular requirements Implants chirurgicaux non actifs Implants de remplacement d'articulation
More informationSection of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou
Section of total knee replacement Total Knee Replacement System Knieendoprothesen System Système de prothèse totale de genou Introduction: This knee system features great versality with its modular component
More informationFemoral Head Diameter, Neck And Taper Length Influence The Mechanical Load And Micromotion In The Taper Connection Of Total Hip Replacements
Femoral Head Diameter, Neck And Taper Length Influence The Mechanical Load And Micromotion In The Taper Connection Of Total Hip Replacements Daniel Kluess, Sarah Bierbaum, Wolfram Mittelmeier, Rainer Bader,
More informationDo ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study.
Thomas Jefferson University Jefferson Digital Commons Rothman Institute Rothman Institute 10-1-2013 Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study. Steven
More informationWear Properties of UHMWPE in CHARITE Artificial Inter-vertebral Disc
Mechanics of Contact and Lubrication, MTM G230 Department of Mechanical & Industrial Enineering Northeastern University Spring 2006 Wear Properties of UHMWPE in CHARITE Artificial Inter-vertebral Disc
More informationRECLAIM REVISION HIP SYSTEM
RECLAIM REVISION HIP SYSTEM Where Strength and Modularity Connect DESIGN RATIONALE System Overview RECLAIM Modular Revision Hip System WHERE STRENGTH & MODULARITY CONNECT 2 Offset Options Proximal Body
More informationCONSENSUS ORTHOPEDICS INC. UNISYN HIP SYSTEM
CONSENSUS ORTHOPEDICS INC. UNISYN HIP SYSTEM Instructions for Use (IFU) IMPORTANT INFORMATION FOR SURGEON: PLEASE READ PRIOR TO IMPLANTING THIS DEVICE IN A CLINICAL SETTING. THE SURGEON SHOULD BE FAMILIAR
More informationFinite element analysis of prosthetic knee joint using ANSYS
Modelling in Medicine and Biology VII 5 Finite element analysis of prosthetic knee joint using ANSYS C. Shashishekar & C. S. Ramesh Siddaganga Institute of Technology, India P.E.S. Institute of Technology,
More informationSupplementary Appendix
Supplementary Appendix This appendix has been provided by the authors to give readers additional information about their work. Supplement to: Ardaugh BM, Graves SE, Redberg RF. The 510(k) ancestry of a
More informationFeaturing. Technology. Product Rationale
Featuring Technology Product Rationale 2 Optimum implant geometry Extending proven TRI-LOCK heritage The original TRI-LOCK Stem was introduced in 1981. This implant was the first proximally coated tapered-wedge
More informationInstrumentation Options
Instrumentation Options With the introduction of Microplasty and Premier Instrumentation platforms and advancements such as our patented Slidex Technology, the Vanguard Complete Knee System is the surgeon
More informationZimmer Segmental System
Zimmer Segmental System Simple solutions for solving complex salvage cases A Step Forward The Zimmer Segmental System is designed to address patients with severe bone loss associated with disease, trauma
More informationMechanical Evaluation of Metal on Metal Total Hip Arthroplasty
Cedarville University DigitalCommons@Cedarville The Research and Scholarship Symposium The 2013 Symposium Apr 10th, 1:00 PM - 5:00 PM Mechanical Evaluation of Metal on Metal Total Hip Arthroplasty Scott
More informationA NEW APPROACH TO BEARING SURFACES FOR TOTAL HIP ARTHROPLASTY
A NEW APPROACH TO BEARING SURFACES FOR TOTAL HIP ARTHROPLASTY by Timothy McTighe, Exec. Dir., JISRF, Chagrin Falls, Ohio Ying Ko, Ph.D., Cincinnati, Ohio Russell B. Bennett, Ph.D., Cincinnati, Ohio James
More information2016 CELEBRATING 15 YEARS OF DATA REPORT NATIONAL JOINT REPLACEMENT REGISTRY. Metal and Ceramic Bearing Surface in Total Conventional Hip Arthroplasty
NATIONAL JOINT REPLACEMENT REGISTRY Metal and Ceramic Bearing Surface in Total Conventional Hip Arthroplasty SUPPLEMENTARY REPORT 2016 CELEBRATING 15 YEARS OF DATA Contents INTRODUCTION...3 Commencement
More informationDesign Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System
Design Rationale and Surgical Technique *smith&nephew TANDEM Bipolar and Unipolar Hip System Maximizing performance from every angle Saving time in the operating room is one of the most valuable solutions
More informationDePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)
References 1. Sanchez-Sotelo J, Haidukewych GJ, Boberg CJ. Hospital Cost of Dislocation After Primary Total Hip Arthroplasty. J Bone Joint Surg. 2006;88A:290-294. 2. Brodner W, Grübl A, Jankovsky R, Meisinger
More informationSYMPOSIUM ON MOBILE BEARING TOTAL KNEE REPLACEMENT DEVICES
SYMPOSIUM ON MOBILE BEARING TOTAL KNEE REPLACEMENT DEVICES Sponsored by ASTM Committee F04 Medical and Surgical Materials and Devices Symposium Chairs: A. Seth Greenwald, D. Phil (Oxon) Orthopaedic Research
More informationBone Conserving Hip Replacement Surgical technique
MiniHip Bone Conserving Hip Replacement Surgical technique MiniHip Contents Operative summary 4 Overview 5 Pre-operative templating 6 Operative technique 7 Neck resection 7 Femoral canal preparation 7
More informationSurgical procedure. METS Modular Proximal Femur
Surgical procedure METS Modular Proximal Femur Surgical Procedure Contents 1.0 2.0 3.0 4.0 5.0 Device information 2 3 1.1 Product overview 1.2 Indications 1.3 Absolute contra-indications 1.4 Relative
More informationStability of Modular Acetabular Components Depends on the Lacking Mechanism Design, Temperature, and Axial Load
University of Tennessee, Knoxville Trace: Tennessee Research and Creative Exchange University of Tennessee Honors Thesis Projects University of Tennessee Honors Program Spring 5-1997 Stability of Modular
More informationUniSyn Hip System. Instrument Catalog
UniSyn Hip System Instrument Catalog UniSyn Hip System Instrument Catalog Table of Contents Introduction... 1 Tray 1... 2 Tray 2... 5 Tray 3... 9 Tray 4...11 Tray 5... 12 Tray 6... 14 Introduction Consensus
More informationOPTIONAL/ADDITIONAL INSTRUMENTS
20 Elevated 6320-36-22 20 Elevated Rim Liner, 36mm OD x 22mm ID 6320-80-22 20 Elevated Rim Liner, 80mm OD x 22mm ID 6320-42-26 20 Elevated Rim Liner, 42mm OD x 26mm ID 6320-80-26 20 Elevated Rim Liner,
More informationBone Preservation Stem
TRI-LOCK Bone Preservation Stem Featuring GRIPTION Coating Surgical Technique Implant Geometry Extending the TRI-LOCK Stem heritage The original TRI-LOCK Stem was introduced in 1981. This implant was
More informationFocal Osteolysis at the Junctions of a Modular Stainless-Steel Femoral Intramedullary Nail
Syracuse University SURFACE Biomedical and Chemical Engineering College of Engineering and Computer Science 2001 Focal Osteolysis at the Junctions of a Modular Stainless-Steel Femoral Intramedullary Nail
More informationMeeting the Challenges of Total Hip Arthroplasty: Approaches, Complications and Contemporary Issues
AAOS/AAHKS/The Hip Society Meeting the Challenges of Total Hip Arthroplasty: Approaches, Complications and Contemporary Issues 16.5 CME Credits SURGICAL SKILLS July 20 22, 2017 OLC Education & Conference
More informationExamination of Porous-Coated Patellar Components and Analysis of the Reasons for Their Retrieval
Examination of Porous-Coated Patellar Components and Analysis of the Reasons for Their Retrieval J. P. Collier,* M. B. Mayor,+ V. A. Surprenant,* H. P. Surprenant,* and R.E. Jensen* *Dartmouth Biomedical
More informationRichard Underwood, Ph.D., CEng, P.E.
Managing Engineer Biomedical Engineering 3440 Market Street, Suite 600 Philadelphia, PA 19104 (215) 594-8875 tel runderwood@exponent.com Professional Profile Dr. Underwood is a Chartered Engineer and Member
More informationPainful Metal-on-Metal Total Hip Arthroplasty
The Journal of Arthroplasty Vol. 21 No. 2 2006 Painful Metal-on-Metal Total Hip Arthroplasty Cambize Shahrdar, MD,* Pat Campbell, PhD,y Joseph Mirra, MD,y and Lawrence D. Dorr, MD* Abstract: Two patients
More informationDIRECT ANTERIOR APPROACH
DIRECT ANTERIOR APPROACH JOINT REPLACEMENT PROGRAM 2301 25TH STREET SOUTH FARGO ND 58103 CENTER FOR MINIMAL INVASIVE JOINT SURGERY (p) 701-241-9300 (tf) 866-887-9300 www.jointpain.md FARGO FERGUS FALLS
More informationExeter. Designed for Anatomic Restoration. Clinical Evidence Education
Exeter Designed for Anatomic Restoration Clinical Evidence Education Anatomic Restoration Exeter re-creating biomechanics In hip replacement, the smallest adjustment can make a big difference. Stryker
More informationVersatility in a proven design. Trilogy Acetabular System
Versatility in a proven design Trilogy Acetabular System Wide-ranging options. Clear-cut solutions. Offering a broad selection of shell and liner configurations, the Trilogy Acetabular System is designed
More informationThe arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006
The arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006 Overview Every patient moves differently 1 and their total hip replacement should be optimised
More informationOperations included in the National Joint Registry (NJR)
Operations included in the National Joint Registry (NJR) Quick links, go to: Hips > Knees > Ankles > Elbows > Shoulders > Trauma > Version 8 June 2018 1 Version control Version number Date Amendments 1
More informationThis is a free sample of content from Basic Stereology. Click here for more information or to buy the book.
BASIC STEREOLOGY FOR BIOLOGISTS AND NEUROSCIENTISTS ALSO FROM COLD SPRING HARBOR LABORATORY PRESS RELATED LABORATORY MANUALS Basic Methods in Microscopy Imaging: A Laboratory Manual Imaging in Developmental
More informationTrusted technology. Trusted performance. Supporting healthcare professionals
Trusted technology. Trusted performance. Supporting healthcare professionals Trusted technology. Trusted performance. The POLAR3 Total Hip Solution, powered by Smith & Nephew s proprietary VERILAST Technology,
More informationSulzer Orthopedics Joint & Fracture Care
Sulzer Orthopedics Joint & Fracture Care Natural-Knee Family Anatomic design for superior clinical results. Natural-Knee Natural-Knee Family: A solution for every knee. Asymmetric design increases coverage
More informationWe are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%
We are IntechOpen, the first native scientific publisher of Open Access books 3,350 108,000 1.7 M Open access books available International authors and editors Downloads Our authors are among the 151 Countries
More informationDocument No Rev. B Pg. 1 of 5 Approvals / Date Title: INSTRUCTIONS FOR USE DJO SURGICAL MODULAR REVISION HIP SYSTEM AND ACETABULAR CAGE
Document No. 0400-0205 Rev. B Pg. 1 of 5 Approvals / Date Title: INSTRUCTIONS FOR USE DJO SURGICAL MODULAR REVISION HIP SYSTEM AND ACETABULAR CAGE Revision ECO Date ECO Summary of Changes Deann Rector
More informationControversies and Complications in Total Hip and Knee Arthroplasty
AORecon Symposium at AAOT 2016 Controversies and Complications in Total Hip and Knee Arthroplasty November 28-29, 2016 Hotel Hilton, Buenos Aires, Argentina. Room: Buen Ayre A+B Chaired by Luigi Zagra
More informationDr. Mont Interview, Baltimore, MD
Dr. Mont Interview, Baltimore, MD Interviewed by Vicky Marlow on September 1, 2008 1.) How did you get started with Hip Resurfacing and tell us about your background and experience as a surgeon. Where
More informationUniglide. Unicompartmental Knee Replacement Product overview
Uniglide Unicompartmental Knee Replacement Product overview Uniglide History Technology Versatility Uniglide is a clinically proven highly congruent, triple radius unicompartmental knee system, offering
More informationA Systematic Review on Performance of the Vanguard Complete Knee System
A Systematic Review on Performance of the Vanguard Complete Knee System Author: Jing Xie, Ph.D. June 30, 2011 Abstract A systematic review was conducted to evaluate the clinical performance of the Vanguard
More informationDISEASES OF THE GASTROESOPHAGEAL MUCOSA
DISEASES OF THE GASTROESOPHAGEAL MUCOSA CLINICAL GASTROENTEROLOGY George Y. Wu, MD, PhD SERIES EDITOR Diseases of the Gastroesophageal Mucosa: The Acid-Related Disorders, edited by James W. Freston, 2001.
More informationOne system for all revision types
Design Rationale 1 Introduction Revisions today are anything but routine. As more patients have their first total hip at a younger age, it s becoming common for many to have multiple revision surgeries
More informationArcos Modular Femoral Revision System
Arcos Modular Femoral Revision System Arcos System Simplify the Complex The Arcos Modular Femoral Revision System meets the demands of complex hip revision surgery by offering surgeons and OR staff the
More information