3 ISBN: ASTM Publication Code Number (PCN): Copyright AMERICAN SOCIETY FOR TESTING AND MATERIALS, West Conshohocken, PA. All rights reserved. This material may not be reproduced or copied, in whole or in part, in any printed, mechanical, electronic, film, or other distribution and storage media, without the written consent of the publisher. Photocopy Rights Authorization to photocopy items for internal, personal, or educational classroom use, or the internal, personal, or educational classroom use of specific clients, is granted by the American Society for Testing and Materials (ASTM) provided that the appropriate fee is paid to the Copyright Clearance Center, 222 Rosewood Dr., Danvers, MA 01923; Tel: ; online: ht.com/. Peer Review Policy Each paper published in this volume was evaluated by two peer reviewers and at least one editor. The authors addressed all of the reviewers' comments to the satisfaction of both the technical editor(s) and the ASTM Committee on Publications. To make technical information available as quickly as possible, the peer-reviewed papers in this publication were prepared "camera-ready" as submitted by the authors. The quality of the papers in this publication reflects not only the obvious efforts of the authors and the technical editor(s), but also the work of these peer reviewers. The ASTM Committee on Publications acknowledges with appreciation their dedication and contribution of time and effort on behalf of ASTM. Printed in Philadelphia, PA March 1997

4 Foreword This publication, Modularity of Orthopedic Implants, contains papers presented at the Symposium on Modularity of Orthopedic Implants held 8 November 1995 in Norfolk, VA. The symposium was sponsored by ASTM Committee F4 on Medical and Surgical Materials and Devices. Donald E. Marlowe, of the FDA Center for Devices and Radiological Health in Rockville, MD; Jack E. Parr, with Wright Medical Technologies in Memphis, TN; and Michael B. Mayor, with the Dartmouth Hitchcock Medical Center in Lebanon, NH, presided as symposium chairmen and are editors of the resulting publication.

5 Contents Overview CLINICAL RELEVANCE A Review of the Use of Modularity in Total Shoulder Arthroplasty JOSEPH D. ZUCKERMAN, RUSSELL J. CAVALLO, AND FREDERICK J. KUMMER ISSUES OF CONCERN The Fibrous Tissue Interface Surrounding Well-Fixed, Revised, Cementless Acetabular Components for Hip Replacement ~ STUART B. GOODMAN, PHIL HUIE, YONG SONG, MIKE O'CONNOR, STEVEN T. WOOLSON, WILLIAM J. MALONEY, DAVID J. SCHURMAN, AND RICHARD SIBLEY 21 Characterization of Solid Products of Corrosion Generated by Modular-Head Femoral Stems of Different Designs and Materials m ROBERT M. URBAN, JOSHUA J. JACOBS, JEREMY L GILBERT, STEPHEN B. RICE, MURALI JASTY, CHARLES R. BRAGDON AND JORGE O. GALANTE 33 The Mechanical and Electrochemical Processes Associated with Taper Fretting Crevice Corrosion: A Review -- JEREMY L GILBERT AND JOSHUA J. JACOBS Wear of Non-Articulating Surfaces in Modular Acetabular Cups JEFFREY J. SHEA, RICHARD D. LAMBERT, AND TERRY W. McLEAN Marking of Ceramic Femoral Heads -- BERNARD J. CALI~S STATE OF THE ART IN PROPERTIES TESTING I Test Method for Fatigue of a Modular Posterior-Stabilized Tibial Component -- MARY E. ANTHONY, MICHAEL B. COOPER, AND JEFFREY A. HOLBROOK Test Method for Evaluating Motion Between the Polymeric Articulating Surface and the Tibial Tray of Modular Total Knee Systems LYNN A. KIRKPATRICK Test Method for the Assessment of Fretting at the Femoral Head and Neck Taper Interface m TERRY W. McLEAN AND RICHARD D. LAMBERT

6 Assessing Morse Taper Function: The Relationship Between Impaction Force, Disassembly Force, and Design Variables m ANDREW H. SCHMIDT DEB A. LOCH, JOAN E. BECHTOLD, AND RICHARD F. KYLE Influence of the Ball/Stem-Interface on the Load Bearing Capability of Modular Total Hip Endoprostheses -- HERBERT G. RICHTER, GERD WILLMAN, MARTIN WIMMER, AND FRANK G. OSTHUES STATE OF THE ART IN PROPERTIES TESTING II Fatigue Integrity Test of a Modular Tibial Stem Extension MICHAEL B. COOPER, MARY E. ANTHONY, ABRAHAM B. SALEHI, AND JEFF A. HOLBROOK Fretting Corrosion Fatigue Study of Modular Joints in Total Hip Replacements by Accelerated In Vitro Testing -- SUSHIL K. BHAMBRI AND LESLIE N. GILBERTSON Corrosion Testing of Modular Hip Implants --JAY R. GOLDBERG, CHRISTINE A. BUCKLEY, JOSHUA J. JACOBS, AND JEREMY L. GILBERT Test Method Comparing Torsional Fatigue of Modular Acetabular Components m RICHARD D. LAMBERT AND TERRY W. McLEAN Effects of Neck Extension, Coverage, and Frequency on the Fretting Corrosion of Modular THR Bore and Cone Interface STANLEY A. BROWN, ALULA ABERA, MARK D'ONOFRIO, AND CURT FLEMMING The Importance of Fatigue Loading When Assessing Liner/Shell Distraction Resistance and Congruency for Modular Acetabular Components DOMINIC R. FOSCO AND DENNIS J. BUCHANAN Fretting Corrosion Mechanisms at Modular Implant Interfaces -- SHILESH C. JANI, WILLARD L. SAUER, TERRY W. McLEAN, RICHARD D. LAMBERT AND PAUL KOVACS Femoral Stem Fatigue Characteristics of Modular Hip Designs -- CHRISTINE S. HEIM, PAUL D. POSTAK, AND A. SETH GREENWALD Author Index Subject Index

7 OD Z 0! rl w L-J! FU Ln! u1

Alternative Bearing Surfaces in Total Joint Replacement

Alternative Bearing Surfaces in Total Joint Replacement STP 1346 Alternative Bearing Surfaces in Total Joint Replacement Joshua J. Jacobs and Thomas L. Craig, Editors ASTM Stock #: STP1346 ASTM 100 Barr Harbor Drive West Conshohocken, PA 19428-2959 Printed

More information

Nondestructive Testing Standards~Present and Future

Nondestructive Testing Standards~Present and Future STP 1151 Nondestructive Testing Standards~Present and Future Harold Berger and Leonard Mordfin, editors ASTM Publication Code Number (PCN) 04-011510-22 1916 Race Street Philadelphia, PA 19103 Library of

More information

Compression Response of Composite Structures

Compression Response of Composite Structures STP 1185 Compression Response of Composite Structures Scott E. Groves and Alton L. Highsmith, Editors ASTM Publication Code Number (PCN): 04-011850-33 1916 Race Street Philadelphia, PA 19103 Printed in

More information

CURRICULUM VITAE CHRISTINE STEUBBEN HEIM Ward Drive Chesterland, OH Telephone:

CURRICULUM VITAE CHRISTINE STEUBBEN HEIM Ward Drive Chesterland, OH Telephone: EDUCATION CURRICULUM VITAE CHRISTINE STEUBBEN HEIM 12655 Ward Drive Chesterland, OH 44026 Telephone: +440 729 9274 B.Sc. (Biomedical Engineering) Case Western Reserve University, Cleveland, Ohio (1992)

More information

Thermomechanical Fatigue Behavior of Materials

Thermomechanical Fatigue Behavior of Materials STP 1186 Thermomechanical Fatigue Behavior of Materials Huseyin Sehitoglu, editor ASTM Publication Code Number (PCN) 04-011860-30 AS M 1916 Race Street Philadelphia, PA 19103 Library of Congress Cataloging-in-Publication

More information

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 EMPIRICAL TESTING CORP. 4628 Northpark Drive Colorado Springs, CO 80918 Dawn Lissy Phone: 719 264 9937 dlissy@empiricaltesting.com MECHANICAL Valid To: January

More information

Trident Ceramic Acetabular System Technical Monograph

Trident Ceramic Acetabular System Technical Monograph Trident Ceramic Acetabular System Technical Monograph Introduction Clinical research and laboratory testing have demonstrated the benefits of ceramic-on-ceramic bearings in THA. Among these benefits are

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that JTL America 3205 Clairmont Ct., Ste. B Fort

More information

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique

Enhanced Stability Constrained Liners. Design Rationale Surgical Technique Enhanced Stability Constrained Liners Design Rationale Surgical Technique The Pinnacle Acetabular Cup System was designed to maximize the number of options available to the surgeon, and provide those options

More information

CERTIFICATE OF ACCREDITATION

CERTIFICATE OF ACCREDITATION CERTIFICATE OF ACCREDITATION ANSI-ASQ National Accreditation Board 500 Montgomery Street, Suite 625, Alexandria, VA 22314, 877-344-3044 This is to certify that JTL America 3205 Clairmont Ct., Ste. B Fort

More information

Specializing in Mechanical Testing for Medical Devices. Office:

Specializing in Mechanical Testing for Medical Devices. Office: Specializing in Mechanical Testing for Medical Devices Office: 260.489.1444 Email: sales@jtlamerica.com www.jtlamerica.com Spine Spinal implant test standards can t keep up with the rapid pace of device

More information

Head and Neck Injuries in Sports

Head and Neck Injuries in Sports STP 1229 Head and Neck Injuries in Sports Earl F. Hoerner, Editor ASTM Publication Code Number (PCN): 0,t 012290-47 ASTM 1916 Race Street Philadelphia, PA 19103 Printed in the U.S.A. Library of Congress

More information

ASTM Committee F04 Tuesday 05/19/2015 Grand Ballroom F Platinum 9

ASTM Committee F04 Tuesday 05/19/2015 Grand Ballroom F Platinum 9 ASTM Committee F04 Tuesday 05/19/2015 Grand Ballroom F Platinum 9 8:00 AM 8:00 AM 10:00 AM 10:00 AM F04 Attendees are invited to an ASTM Training Session on Responsibilities for Subcommittee Chairman,

More information

Spinal Implants: Are We Evaluating Them Appropriately?

Spinal Implants: Are We Evaluating Them Appropriately? STP 1431 Spinal Implants: Are We Evaluating Them Appropriately? M. N. Melkerson, M. S.; S. L. Griffith, Ph.D.; and J. S. Kirkpatrick, M.D., editors ASTM Stock Number: STP 1431 m l ASTM International 100

More information

Reaching new heights. Comprehensive. Efficient. Simple.

Reaching new heights. Comprehensive. Efficient. Simple. Reaching new heights Comprehensive. Efficient. Simple. Various acetabular cup choices Compatible with the different head and liner options including VERILAST Technology Reach for proven OR efficient Instrumentation

More information

UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD

UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD UHMWPE LONGEVITY: INFLUENCES OF THE ORTHOPAEDIC TRIAD AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS 66th Annual Meeting February 4-9, 1999 Anaheim, California COMMITTEE ON BIOMEDICAL ENGINEERING COMMITTEE ON

More information

CLASSIFICATION OF MOBILE BEARING KNEE DESIGN: MOBILITY AND CONSTRAINT

CLASSIFICATION OF MOBILE BEARING KNEE DESIGN: MOBILITY AND CONSTRAINT CLASSIFICATION OF MOBILE BEAING KNEE DESIGN: MOBILITY AND CONSTAINT Orthopaedic esearch Laboratories Lutheran Hospital Cleveland Clinic Health System Christine S. Heim, B.Sc. Paul. D. Postak, B.Sc. Nicholas

More information

Optimum implant geometry

Optimum implant geometry Design Rationale Optimum implant geometry Extending proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available

More information

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis?

Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis? Case report: Pain L THR [ post THR 2 years; with history of trivial fall] Your Diagnosis? Diagnosis: Ceramic head fracture In the 1970 s, Boutin implemented ceramic in modern total hip arthroplasty (THA).

More information

Optimum implant geometry

Optimum implant geometry Design Rationale Optimum implant geometry Extending the proven Tri-Lock heritage The original Tri-Lock was introduced in 1981. This implant was the first proximally coated tapered-wedge hip stem available

More information

ReCap Product Rationale

ReCap Product Rationale ReCap Product Rationale A Complete resurfacing system designe engineering principles, tried and tested m clinically proven fixation methods Biomet UK Ltd Waterton Industrial Estate Bridgend, South Wales

More information

ICF-based Clinical Practice Guidelines for Common Musculoskeletal Conditions. Board of Directors Meeting. February 2015

ICF-based Clinical Practice Guidelines for Common Musculoskeletal Conditions. Board of Directors Meeting. February 2015 ICF-based Clinical Practice Guidelines for Common Musculoskeletal Conditions Board of Directors Meeting February 2015 Submitted by: Joe Godges DPT* and Christine McDonough PT, PhD** *ICF-based Clinical

More information

Scan Bi-Polar 22/28. Operative Technique

Scan Bi-Polar 22/28. Operative Technique Scan Bi-Polar 22/28 Operative Technique Disclaimer This publication and all content, artwork, photographs, names, logos and marks contained in it are protected by copyright, trademarks and other intellectual

More information

1.1 Ceramic on Ceramic Bearings Used with Proximal Modular Stems in THA K. J. Keggi, J. M. Keggi, R. E. Kennon and T. McTighe

1.1 Ceramic on Ceramic Bearings Used with Proximal Modular Stems in THA K. J. Keggi, J. M. Keggi, R. E. Kennon and T. McTighe 1.1 Ceramic on Ceramic Bearings Used with Proximal Modular Stems in THA K. J. Keggi, J. M. Keggi, R. E. Kennon and T. McTighe Abstract Introduction: Osteolysis generated by wear debris remains a problem

More information

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head

Enhancing stability and increasing range of motion. Metasul LDH Large Diameter Head Enhancing stability and increasing range of motion Metasul LDH Large Diameter Head The Metasul large diameter head technology is the result of in-depth research, development and clinical experience that

More information

Optimizing function Maximizing survivorship Accelerating recovery

Optimizing function Maximizing survivorship Accelerating recovery Surgical Technique Optimizing Function Maximizing Survivorship Accelerating Recovery The company believes in an approach to patient treatment that places equal importance on: Optimizing function Maximizing

More information

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter

Cement Polished Tapered Stems of 12/14 Taper. 96 mm 98 mm 104 mm 110 mm 116 mm 122 mm 128 mm. Ceramic Femoral Head. Outer Diameter Design Philosophy Cementless Stems of 12/14 Taper Stem Length Neck shaft Angle STEM-N3 STEM-N4 STEM-N5 STEM-N6 STEM-N7 STEM-N8 STEM-N9 123 mm 125 mm 130 mm 135 mm 140 mm 145 mm 150 mm 132 Cement Polished

More information

DAMAGE IN COMPOSITE MATERIALS: BASIC MECHANISMS, ACCUMULATION, TOLERANCE, AND CHARACTERIZATION

DAMAGE IN COMPOSITE MATERIALS: BASIC MECHANISMS, ACCUMULATION, TOLERANCE, AND CHARACTERIZATION DAMAGE IN COMPOSITE MATERIALS: BASIC MECHANISMS, ACCUMULATION, TOLERANCE, AND CHARACTERIZATION A symposium sponsored by ASTM Committees E-7 on Nondestructive Testing and E-9 on Fatigue Bal Harbour, Fla.,

More information

Rotating Platform System. Product Rationale

Rotating Platform System. Product Rationale References 1. Meftah M, Ranawat A, Ranawat C. Ten-Year Follow-up of a Rotating-Platform, Posterior-Stabilised Total Knee Arthroplasty. J Bone Joint Surg Am. 2012; 94:426-32 2. Dalury D, Gonzales R, Adams

More information

ISO INTERNATIONAL STANDARD

ISO INTERNATIONAL STANDARD INTERNATIONAL STANDARD ISO 7206-2 Third edition 2011-04-01 Implants for surgery Partial and total hip joint prostheses Part 2: Articulating surfaces made of metallic, ceramic and plastics materials Implants

More information

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique

ESC. Enhanced Stability Liners. Design Rationale & Surgical Technique ESC Enhanced Stability Liners Design Rationale & Surgical Technique Choice Without Compromise DePuy Synthes PINNACLE Hip Solutions are designed with a wide range of acetabular cup options, biological and

More information

MetaFix Cementless Total Hip Replacement Product overview

MetaFix Cementless Total Hip Replacement Product overview MetaFix Cementless Total Hip Replacement Product overview MetaFix Evolution Versatility Simplicity Founded on 20 years experience in cementless technology with a proven, world-leading stem design, MetaFix

More information

Operations included in the National Joint Registry (NJR) Quick links, go to: Hips > Knees > Ankles > Elbows > Shoulders > Trauma >

Operations included in the National Joint Registry (NJR) Quick links, go to: Hips > Knees > Ankles > Elbows > Shoulders > Trauma > Operations included in the National Joint Registry (NJR) Quick links, go to: Hips > Knees > Ankles > Elbows > Shoulders > Trauma > Version 5 December 2013 1 Version control Version number Date Amendments

More information

MULTIPOLAR BIPOLAR CUP. Surgical Technique

MULTIPOLAR BIPOLAR CUP. Surgical Technique MULTIPOLAR BIPOLAR CUP Surgical Technique MULTIPOLAR BIPOLAR CUP ASSEMBLY 1PREASSEMBLY (BACK TABLE) TECHNIQUE INSERT FEMORAL HEAD Seat the femoral head securely in the polyethylene liner. The inner split

More information

REFLECTION Constrained Liner Introduction

REFLECTION Constrained Liner Introduction Surgical Technique REFLECTION Constrained Liner Introduction Surgical treatment of recurrent dislocation should be directed toward correction of any mechanical abnormalities. If dislocation is caused

More information

Publications and Presentations. B.A., Biology, University of Kansas, Lawrence, M.D., Cornell University Medical College, New York, 1979

Publications and Presentations. B.A., Biology, University of Kansas, Lawrence, M.D., Cornell University Medical College, New York, 1979 Publications and Presentations Name: James B. Grimes, M.D. Education: B.A., Biology, University of Kansas, Lawrence, 1975 M.D., Cornell University Medical College, New York, 1979 Graduate Hospital Clinical

More information

The power of simplicity

The power of simplicity The power of simplicity The power of simplicity Consider the facts, and take a look at the future: Revision TKA procedures are projected to double between now and 2015. 1 Restoration of a normal joint

More information

Ovation Hip System. Surgical Technique

Ovation Hip System. Surgical Technique Ovation Hip System Surgical Technique Ovation Hip System Surgical Technique Ovation Designing Surgeons: Andrew Petrella, M.D. Lecanto, FL Richard Vlasak, M.D. Gainesville, FL Ovation Tribute Designing

More information

Bi-Polar 22.2mm & 28mm System - Operative technique

Bi-Polar 22.2mm & 28mm System - Operative technique Disclaimer Biomet UK Ltd, as the manufacturer of this device, does not practice medicine and does not recommend any particular surgical technique for use on a specific patient. The surgeon who performs

More information

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology

Regenerex Porous Titanium Construct. Knees Hips Extremities Cement and Accessories PMI Trauma Technology Regenerex Porous Titanium Construct Knees Hips Extremities Cement and Accessories PMI Trauma Technology One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon provide personalized

More information

The Leader in Orthopaedic Innovation

The Leader in Orthopaedic Innovation The Leader in Orthopaedic Innovation Wright is a leading international manufacturer and distributor of superior, easy to use, and innovative orthopaedic implants and instrumentation. For over 50 years,

More information

Trabecular Metal Primary Hip Prosthesis

Trabecular Metal Primary Hip Prosthesis Trabecular Metal Primary Hip Prosthesis Quick-Reference Guide The Best Thing Next to Bone Trabecular Metal Primary Hip Prosthesis Quick-Reference Guide Key Features & Benefits Proximal Trabecular Metal

More information

M-SERIES. Modular Femoral Stem AN ACCURATE MATCH EVERY TIME

M-SERIES. Modular Femoral Stem AN ACCURATE MATCH EVERY TIME M-SERIES Modular Femoral Stem AN ACCURATE MATCH EVERY TIME 54 Extension 114 Flexion High How do you ensure optimal post-operative joint stability? MECHANICAL RANGE OF MOTION Cup Position: 45 degrees abduction,

More information

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY

FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY FIXATION FIRST WEAR REDUCTION OXIDATIVE STABILITY MECHANICAL INTEGRITY PROVEN TECHNOLOGY Fixation First FIXATION FIRST 1958 Charnley Hip Over 1,000,000 implanted 1 96.2 percent survivorship at 32 years

More information

Accumulation in Liver and Spleen of Metal Particles Generated at Nonbearing Surfaces in Hip Arthroplasty

Accumulation in Liver and Spleen of Metal Particles Generated at Nonbearing Surfaces in Hip Arthroplasty The Journal of Arthroplasty Vol. 19 No. 8 Suppl. 3 2004 Accumulation in Liver and Spleen of Metal Particles Generated at Nonbearing Surfaces in Hip Arthroplasty Robert M. Urban, AS, Michael J. Tomlinson,

More information

HOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX

HOSPITAL A (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX HOSPITAL "A" (2007) ORTHOPEDIC JOINT IMPLANT COMPONENT MATRIX HIP IMPLANTS TOTAL HIPS Ultra High Demand (metal on metal) Femur, ingrowth Femoral head, metal Acetabular shell, ingrowth Acetabular liner,

More information

Product Rationale. Where Strength and Modularity Connect

Product Rationale. Where Strength and Modularity Connect Product Rationale Where Strength and Modularity Connect 2 ReClaim Modular Revision Hip System Advanced Strength 1 Advanced Strength Over 600 million cycles of testing 1 Advanced Fixation Advanced Instrumentation

More information

SYMPOSIUM ON MODULARITY & TAPERS IN TOTAL JOINT REPLACEMENT DEVICES. Sponsored by ASTM Committee F04 Medical & Surgical Materials & Devices

SYMPOSIUM ON MODULARITY & TAPERS IN TOTAL JOINT REPLACEMENT DEVICES. Sponsored by ASTM Committee F04 Medical & Surgical Materials & Devices November 10, 2014 Sheraton New Orleans New Orleans, LA SYMPOSIUM ON MODULARITY & TAPERS IN TOTAL JOINT REPLACEMENT DEVICES Sponsored by ASTM Committee F04 Medical & Surgical Materials & Devices Symposium

More information

METHODS AND MODELS FOR PREDICTING FATIGUE CRACK GROWTH UNDER RANDOM LOADING

METHODS AND MODELS FOR PREDICTING FATIGUE CRACK GROWTH UNDER RANDOM LOADING METHODS AND MODELS FOR PREDICTING FATIGUE CRACK GROWTH UNDER RANDOM LOADING Sponsored by ASTM Subcommittee E24.06 on Fracture Mechanics Applications AMERICAN SOCIETY FOR TESTING AND MATERIALS ASTM SPECIAL

More information

Retrieval analysis of metal and ceramic femoral heads on a single CoCr stem design

Retrieval analysis of metal and ceramic femoral heads on a single CoCr stem design Retrieval analysis of metal and ceramic femoral heads on a single CoCr stem design The Harvard community has made this article openly available. Please share how this access benefits you. Your story matters.

More information

Knee Replacement Implants

Knee Replacement Implants Knee Replacement Implants During knee replacement surgery, an orthopaedic surgeon will resurface your damaged knee with artificial components, called implants. There are many different types of implants.

More information

Sinus Headache, Migraine, and the Otolaryngologist

Sinus Headache, Migraine, and the Otolaryngologist Sinus Headache, Migraine, and the Otolaryngologist Mark E. Mehle Editor Sinus Headache, Migraine, and the Otolaryngologist A Comprehensive Clinical Guide 123 Editor Mark E. Mehle Private Practice ENT and

More information

PINNACLE REVISION CUP SYSTEM

PINNACLE REVISION CUP SYSTEM PINNACLE REVISION CUP SYSTEM This publication is not intended for distribution in the USA. DESIGN RATIONALE FLEXIBILITY. PRECISION. CONFIDENCE. DePuy Synthes Joint Reconstruction is proud to offer the

More information

CORRELATING SENSORY OBJECTIVE MEASUREMENTS- NEW METHODS FOR ANSWERING OLD PROBLEMS

CORRELATING SENSORY OBJECTIVE MEASUREMENTS- NEW METHODS FOR ANSWERING OLD PROBLEMS CORRELATING SENSORY OBJECTIVE MEASUREMENTS- NEW METHODS FOR ANSWERING OLD PROBLEMS A symposium sponsored by ASTM Committee E-18 on Sensory Evaluation of Materials and Products AMERICAN SOCIETY FOR TESTING

More information

ISO INTERNATIONAL STANDARD. Non-active surgical implants Joint replacement implants Particular requirements

ISO INTERNATIONAL STANDARD. Non-active surgical implants Joint replacement implants Particular requirements INTERNATIONAL STANDARD ISO 21534 Second edition 2007-10-01 Non-active surgical implants Joint replacement implants Particular requirements Implants chirurgicaux non actifs Implants de remplacement d'articulation

More information

Section of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou

Section of total knee replacement. Total Knee Replacement System. Knieendoprothesen System. Système de prothèse totale de genou Section of total knee replacement Total Knee Replacement System Knieendoprothesen System Système de prothèse totale de genou Introduction: This knee system features great versality with its modular component

More information

Femoral Head Diameter, Neck And Taper Length Influence The Mechanical Load And Micromotion In The Taper Connection Of Total Hip Replacements

Femoral Head Diameter, Neck And Taper Length Influence The Mechanical Load And Micromotion In The Taper Connection Of Total Hip Replacements Femoral Head Diameter, Neck And Taper Length Influence The Mechanical Load And Micromotion In The Taper Connection Of Total Hip Replacements Daniel Kluess, Sarah Bierbaum, Wolfram Mittelmeier, Rainer Bader,

More information

Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study.

Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study. Thomas Jefferson University Jefferson Digital Commons Rothman Institute Rothman Institute 10-1-2013 Do ceramic femoral heads reduce taper fretting corrosion in hip arthroplasty? A retrieval study. Steven

More information

Wear Properties of UHMWPE in CHARITE Artificial Inter-vertebral Disc

Wear Properties of UHMWPE in CHARITE Artificial Inter-vertebral Disc Mechanics of Contact and Lubrication, MTM G230 Department of Mechanical & Industrial Enineering Northeastern University Spring 2006 Wear Properties of UHMWPE in CHARITE Artificial Inter-vertebral Disc

More information

RECLAIM REVISION HIP SYSTEM

RECLAIM REVISION HIP SYSTEM RECLAIM REVISION HIP SYSTEM Where Strength and Modularity Connect DESIGN RATIONALE System Overview RECLAIM Modular Revision Hip System WHERE STRENGTH & MODULARITY CONNECT 2 Offset Options Proximal Body

More information

CONSENSUS ORTHOPEDICS INC. UNISYN HIP SYSTEM

CONSENSUS ORTHOPEDICS INC. UNISYN HIP SYSTEM CONSENSUS ORTHOPEDICS INC. UNISYN HIP SYSTEM Instructions for Use (IFU) IMPORTANT INFORMATION FOR SURGEON: PLEASE READ PRIOR TO IMPLANTING THIS DEVICE IN A CLINICAL SETTING. THE SURGEON SHOULD BE FAMILIAR

More information

Finite element analysis of prosthetic knee joint using ANSYS

Finite element analysis of prosthetic knee joint using ANSYS Modelling in Medicine and Biology VII 5 Finite element analysis of prosthetic knee joint using ANSYS C. Shashishekar & C. S. Ramesh Siddaganga Institute of Technology, India P.E.S. Institute of Technology,

More information

Supplementary Appendix

Supplementary Appendix Supplementary Appendix This appendix has been provided by the authors to give readers additional information about their work. Supplement to: Ardaugh BM, Graves SE, Redberg RF. The 510(k) ancestry of a

More information

Featuring. Technology. Product Rationale

Featuring. Technology. Product Rationale Featuring Technology Product Rationale 2 Optimum implant geometry Extending proven TRI-LOCK heritage The original TRI-LOCK Stem was introduced in 1981. This implant was the first proximally coated tapered-wedge

More information

Instrumentation Options

Instrumentation Options Instrumentation Options With the introduction of Microplasty and Premier Instrumentation platforms and advancements such as our patented Slidex Technology, the Vanguard Complete Knee System is the surgeon

More information

Zimmer Segmental System

Zimmer Segmental System Zimmer Segmental System Simple solutions for solving complex salvage cases A Step Forward The Zimmer Segmental System is designed to address patients with severe bone loss associated with disease, trauma

More information

Mechanical Evaluation of Metal on Metal Total Hip Arthroplasty

Mechanical Evaluation of Metal on Metal Total Hip Arthroplasty Cedarville University DigitalCommons@Cedarville The Research and Scholarship Symposium The 2013 Symposium Apr 10th, 1:00 PM - 5:00 PM Mechanical Evaluation of Metal on Metal Total Hip Arthroplasty Scott

More information

A NEW APPROACH TO BEARING SURFACES FOR TOTAL HIP ARTHROPLASTY

A NEW APPROACH TO BEARING SURFACES FOR TOTAL HIP ARTHROPLASTY A NEW APPROACH TO BEARING SURFACES FOR TOTAL HIP ARTHROPLASTY by Timothy McTighe, Exec. Dir., JISRF, Chagrin Falls, Ohio Ying Ko, Ph.D., Cincinnati, Ohio Russell B. Bennett, Ph.D., Cincinnati, Ohio James

More information

2016 CELEBRATING 15 YEARS OF DATA REPORT NATIONAL JOINT REPLACEMENT REGISTRY. Metal and Ceramic Bearing Surface in Total Conventional Hip Arthroplasty

2016 CELEBRATING 15 YEARS OF DATA REPORT NATIONAL JOINT REPLACEMENT REGISTRY. Metal and Ceramic Bearing Surface in Total Conventional Hip Arthroplasty NATIONAL JOINT REPLACEMENT REGISTRY Metal and Ceramic Bearing Surface in Total Conventional Hip Arthroplasty SUPPLEMENTARY REPORT 2016 CELEBRATING 15 YEARS OF DATA Contents INTRODUCTION...3 Commencement

More information

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System

Design Rationale and Surgical Technique. *smith&nephew TANDEM. Bipolar and Unipolar Hip System Design Rationale and Surgical Technique *smith&nephew TANDEM Bipolar and Unipolar Hip System Maximizing performance from every angle Saving time in the operating room is one of the most valuable solutions

More information

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574)

DePuy Orthopaedics, Inc. 700 Orthopaedic Drive Warsaw, IN USA Tel: +1 (800) Fax: +1 (574) References 1. Sanchez-Sotelo J, Haidukewych GJ, Boberg CJ. Hospital Cost of Dislocation After Primary Total Hip Arthroplasty. J Bone Joint Surg. 2006;88A:290-294. 2. Brodner W, Grübl A, Jankovsky R, Meisinger

More information

SYMPOSIUM ON MOBILE BEARING TOTAL KNEE REPLACEMENT DEVICES

SYMPOSIUM ON MOBILE BEARING TOTAL KNEE REPLACEMENT DEVICES SYMPOSIUM ON MOBILE BEARING TOTAL KNEE REPLACEMENT DEVICES Sponsored by ASTM Committee F04 Medical and Surgical Materials and Devices Symposium Chairs: A. Seth Greenwald, D. Phil (Oxon) Orthopaedic Research

More information

Bone Conserving Hip Replacement Surgical technique

Bone Conserving Hip Replacement Surgical technique MiniHip Bone Conserving Hip Replacement Surgical technique MiniHip Contents Operative summary 4 Overview 5 Pre-operative templating 6 Operative technique 7 Neck resection 7 Femoral canal preparation 7

More information

Surgical procedure. METS Modular Proximal Femur

Surgical procedure. METS Modular Proximal Femur Surgical procedure METS Modular Proximal Femur Surgical Procedure Contents 1.0 2.0 3.0 4.0 5.0 Device information 2 3 1.1 Product overview 1.2 Indications 1.3 Absolute contra-indications 1.4 Relative

More information

Stability of Modular Acetabular Components Depends on the Lacking Mechanism Design, Temperature, and Axial Load

Stability of Modular Acetabular Components Depends on the Lacking Mechanism Design, Temperature, and Axial Load University of Tennessee, Knoxville Trace: Tennessee Research and Creative Exchange University of Tennessee Honors Thesis Projects University of Tennessee Honors Program Spring 5-1997 Stability of Modular

More information

UniSyn Hip System. Instrument Catalog

UniSyn Hip System. Instrument Catalog UniSyn Hip System Instrument Catalog UniSyn Hip System Instrument Catalog Table of Contents Introduction... 1 Tray 1... 2 Tray 2... 5 Tray 3... 9 Tray 4...11 Tray 5... 12 Tray 6... 14 Introduction Consensus

More information

OPTIONAL/ADDITIONAL INSTRUMENTS

OPTIONAL/ADDITIONAL INSTRUMENTS 20 Elevated 6320-36-22 20 Elevated Rim Liner, 36mm OD x 22mm ID 6320-80-22 20 Elevated Rim Liner, 80mm OD x 22mm ID 6320-42-26 20 Elevated Rim Liner, 42mm OD x 26mm ID 6320-80-26 20 Elevated Rim Liner,

More information

Bone Preservation Stem

Bone Preservation Stem TRI-LOCK Bone Preservation Stem Featuring GRIPTION Coating Surgical Technique Implant Geometry Extending the TRI-LOCK Stem heritage The original TRI-LOCK Stem was introduced in 1981. This implant was

More information

Focal Osteolysis at the Junctions of a Modular Stainless-Steel Femoral Intramedullary Nail

Focal Osteolysis at the Junctions of a Modular Stainless-Steel Femoral Intramedullary Nail Syracuse University SURFACE Biomedical and Chemical Engineering College of Engineering and Computer Science 2001 Focal Osteolysis at the Junctions of a Modular Stainless-Steel Femoral Intramedullary Nail

More information

Meeting the Challenges of Total Hip Arthroplasty: Approaches, Complications and Contemporary Issues

Meeting the Challenges of Total Hip Arthroplasty: Approaches, Complications and Contemporary Issues AAOS/AAHKS/The Hip Society Meeting the Challenges of Total Hip Arthroplasty: Approaches, Complications and Contemporary Issues 16.5 CME Credits SURGICAL SKILLS July 20 22, 2017 OLC Education & Conference

More information

Examination of Porous-Coated Patellar Components and Analysis of the Reasons for Their Retrieval

Examination of Porous-Coated Patellar Components and Analysis of the Reasons for Their Retrieval Examination of Porous-Coated Patellar Components and Analysis of the Reasons for Their Retrieval J. P. Collier,* M. B. Mayor,+ V. A. Surprenant,* H. P. Surprenant,* and R.E. Jensen* *Dartmouth Biomedical

More information

Richard Underwood, Ph.D., CEng, P.E.

Richard Underwood, Ph.D., CEng, P.E. Managing Engineer Biomedical Engineering 3440 Market Street, Suite 600 Philadelphia, PA 19104 (215) 594-8875 tel runderwood@exponent.com Professional Profile Dr. Underwood is a Chartered Engineer and Member

More information

Painful Metal-on-Metal Total Hip Arthroplasty

Painful Metal-on-Metal Total Hip Arthroplasty The Journal of Arthroplasty Vol. 21 No. 2 2006 Painful Metal-on-Metal Total Hip Arthroplasty Cambize Shahrdar, MD,* Pat Campbell, PhD,y Joseph Mirra, MD,y and Lawrence D. Dorr, MD* Abstract: Two patients

More information

DIRECT ANTERIOR APPROACH

DIRECT ANTERIOR APPROACH DIRECT ANTERIOR APPROACH JOINT REPLACEMENT PROGRAM 2301 25TH STREET SOUTH FARGO ND 58103 CENTER FOR MINIMAL INVASIVE JOINT SURGERY (p) 701-241-9300 (tf) 866-887-9300 www.jointpain.md FARGO FERGUS FALLS

More information

Exeter. Designed for Anatomic Restoration. Clinical Evidence Education

Exeter. Designed for Anatomic Restoration. Clinical Evidence Education Exeter Designed for Anatomic Restoration Clinical Evidence Education Anatomic Restoration Exeter re-creating biomechanics In hip replacement, the smallest adjustment can make a big difference. Stryker

More information

Versatility in a proven design. Trilogy Acetabular System

Versatility in a proven design. Trilogy Acetabular System Versatility in a proven design Trilogy Acetabular System Wide-ranging options. Clear-cut solutions. Offering a broad selection of shell and liner configurations, the Trilogy Acetabular System is designed

More information

The arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006

The arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006 The arc of pelvic motion has been shown to be as great as 70 through sit to stand activities 1 DiGioia CORR 2006 Overview Every patient moves differently 1 and their total hip replacement should be optimised

More information

Operations included in the National Joint Registry (NJR)

Operations included in the National Joint Registry (NJR) Operations included in the National Joint Registry (NJR) Quick links, go to: Hips > Knees > Ankles > Elbows > Shoulders > Trauma > Version 8 June 2018 1 Version control Version number Date Amendments 1

More information

This is a free sample of content from Basic Stereology. Click here for more information or to buy the book.

This is a free sample of content from Basic Stereology. Click here for more information or to buy the book. BASIC STEREOLOGY FOR BIOLOGISTS AND NEUROSCIENTISTS ALSO FROM COLD SPRING HARBOR LABORATORY PRESS RELATED LABORATORY MANUALS Basic Methods in Microscopy Imaging: A Laboratory Manual Imaging in Developmental

More information

Trusted technology. Trusted performance. Supporting healthcare professionals

Trusted technology. Trusted performance. Supporting healthcare professionals Trusted technology. Trusted performance. Supporting healthcare professionals Trusted technology. Trusted performance. The POLAR3 Total Hip Solution, powered by Smith & Nephew s proprietary VERILAST Technology,

More information

Sulzer Orthopedics Joint & Fracture Care

Sulzer Orthopedics Joint & Fracture Care Sulzer Orthopedics Joint & Fracture Care Natural-Knee Family Anatomic design for superior clinical results. Natural-Knee Natural-Knee Family: A solution for every knee. Asymmetric design increases coverage

More information

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1%

We are IntechOpen, the first native scientific publisher of Open Access books. International authors and editors. Our authors are among the TOP 1% We are IntechOpen, the first native scientific publisher of Open Access books 3,350 108,000 1.7 M Open access books available International authors and editors Downloads Our authors are among the 151 Countries

More information

Document No Rev. B Pg. 1 of 5 Approvals / Date Title: INSTRUCTIONS FOR USE DJO SURGICAL MODULAR REVISION HIP SYSTEM AND ACETABULAR CAGE

Document No Rev. B Pg. 1 of 5 Approvals / Date Title: INSTRUCTIONS FOR USE DJO SURGICAL MODULAR REVISION HIP SYSTEM AND ACETABULAR CAGE Document No. 0400-0205 Rev. B Pg. 1 of 5 Approvals / Date Title: INSTRUCTIONS FOR USE DJO SURGICAL MODULAR REVISION HIP SYSTEM AND ACETABULAR CAGE Revision ECO Date ECO Summary of Changes Deann Rector

More information

Controversies and Complications in Total Hip and Knee Arthroplasty

Controversies and Complications in Total Hip and Knee Arthroplasty AORecon Symposium at AAOT 2016 Controversies and Complications in Total Hip and Knee Arthroplasty November 28-29, 2016 Hotel Hilton, Buenos Aires, Argentina. Room: Buen Ayre A+B Chaired by Luigi Zagra

More information

Dr. Mont Interview, Baltimore, MD

Dr. Mont Interview, Baltimore, MD Dr. Mont Interview, Baltimore, MD Interviewed by Vicky Marlow on September 1, 2008 1.) How did you get started with Hip Resurfacing and tell us about your background and experience as a surgeon. Where

More information

Uniglide. Unicompartmental Knee Replacement Product overview

Uniglide. Unicompartmental Knee Replacement Product overview Uniglide Unicompartmental Knee Replacement Product overview Uniglide History Technology Versatility Uniglide is a clinically proven highly congruent, triple radius unicompartmental knee system, offering

More information

A Systematic Review on Performance of the Vanguard Complete Knee System

A Systematic Review on Performance of the Vanguard Complete Knee System A Systematic Review on Performance of the Vanguard Complete Knee System Author: Jing Xie, Ph.D. June 30, 2011 Abstract A systematic review was conducted to evaluate the clinical performance of the Vanguard

More information

DISEASES OF THE GASTROESOPHAGEAL MUCOSA

DISEASES OF THE GASTROESOPHAGEAL MUCOSA DISEASES OF THE GASTROESOPHAGEAL MUCOSA CLINICAL GASTROENTEROLOGY George Y. Wu, MD, PhD SERIES EDITOR Diseases of the Gastroesophageal Mucosa: The Acid-Related Disorders, edited by James W. Freston, 2001.

More information

One system for all revision types

One system for all revision types Design Rationale 1 Introduction Revisions today are anything but routine. As more patients have their first total hip at a younger age, it s becoming common for many to have multiple revision surgeries

More information

Arcos Modular Femoral Revision System

Arcos Modular Femoral Revision System Arcos Modular Femoral Revision System Arcos System Simplify the Complex The Arcos Modular Femoral Revision System meets the demands of complex hip revision surgery by offering surgeons and OR staff the

More information