BOOK CHAPTERS PUBLICATIONS

Size: px
Start display at page:

Download "BOOK CHAPTERS PUBLICATIONS"

Transcription

1 BOOK CHAPTERS Wright T, Komistek RD, Imhauser C, Sharma A: Biomechanics of Total Knee Arthroplasty. Advanced Reconstruction Knee, Chapter 5: AAOS Publication Dec Sharma A, Komistek RD: Contact Mechanics of the Human Knee. Insall Scott Surgery of the Knee, 5 th edition, Chapter 15. Elsevier, PUBLICATIONS Sharma A, Dennis DA, Zingde SM, Mahfouz MR, Komistek RD: Femoral Condylar Contact Points Start and Remain Posterior in High Flexing Patients. J Arthroplasty (in press). Nakamura S, Sharma A, Kobayashi M, Ito H, Nakamura K, Zingde SM, Nakamura T, Komistek RD: 3D In Vivo Femoro-Tibial Kinematics of Tri-condylar Total Knee Arthroplasty during Kneeling Activities. The Knee (in press) Zingde SM, Leszko F, Sharma A, Mahfouz MR, Komistek RD, Dennis DA: In Vivo Determination of Cam-Post Engagement in Fixed and Mobile-bearing TKA. Clin Orthop Relat Res 2013 [Epub. Ahead of print]. Cheng JS, Carr CB, Wong C, Sharma A, Mahfouz MR, Komistek RD: Altered Spinal Motion in Low back Pain Associated with Lumbar Strain and Spondylosis. J. Evid Based Spine Care. 2013(4): Johnson JM, Mahfouz M, Battaglia NV, Sharma A, Cheng JS, Komistek RD: Clinical and Statistical Correlation of Various Lumbar Pathological Conditions. J. Biomech Feb 22; 46(4): Lebow RL, Adogwa O, Parker SL, Sharma A, Cheng J, McGirt MJ: Asymptomatic Same-site Recurrent Disc Herniation After Lumbar Disectomy: Results of a Prospective Longitudinal Study with Two-year Serial Imaging. Spine 2011 Dec 1; 36(25): Dennis DA, Kim RH, Johnson DR, Springer BD, Fehring TK, Sharma A: Control-Matched Evaluation of Patellar Crepitus After Total Knee Arthroplasty. Clin Orthop Relat Res 2011 Jan 469(1): Sharma A, Komistek RD, Mahfouz MR: In Vivo Kinematics Evaluation in Flexion of Patients Implanted with Primary TKA. Techniques in Knee Surgery 2011 Jun 10(2) Barnes CL, Sharma A, Blaha JD, Nambu S, Carroll M: Kneeling is safe for patients implanted with medial pivot TKR designs. J Arthroplasty 2011 Jun 26(4): Dennis DA, Komistek RD, Kim RH, Sharma A: Gap Balancing Versus Measured Resection technique for Total Knee Arthroplasty. Clin Orthop Relat Res 2010 Jan 468(1): Victor J, Mueller JK, Komistek RD, Sharma A, Nadaud MC, Bellemans J: In Vivo Kinematics after Cruciate-substituting TKA. Clin Orthop Relat Res 2010 Mar 468(3): Leszko F, Sharma A, Komistek RD, Mahfouz MR, Cates HE, Scuderi GR: Comparison of In Vivo Patellofemoral Kinematics for Subjects Having High-Flexion Total Knee Arthroplasty Implant With Patients Having Normal Knees. J Arthroplasty 2010 Apr 25(3): Yang CC, McFadden LA, Dennis DA, Kim RH, Sharma A: Lateral Retinacular Release Rates in Mobile Versus Fixed bearing TKA. Clin Orthop Relat Res 2008 Nov 466(11): Sharma A, Leszko F, Komistek RD, Scuderi GR, Cates HE Jr., Liu F: In Vivo Patellofemoral Forces in High Flexion Total Knee Arthroplasty. J Biomech 2008; 41(3): Sharma A, Komistek RD, Scuderi GR, Cates HE: High Flexion TKA Designs: What are their in Vivo Contact Mechanics? Clin Orthop Relat Res 2007 Nov; 464: Adrija Sharma, page 1

2 Sharma A, Komistek RD, Ranawat CS, Dennis DA, Mahfouz MR: In Vivo Contact Pressures in Total Knee Arthroplasty. J Arthroplasty 2007 Apr; 22(3): Liu F, Cheng J, Komistek RD, Mahfouz MR, Sharma A: In Vivo Evaluation of Dynamic Characteristics of the Normal, Fused and Disc Replacement Cervical Spine. Spine 2007 Nov 1; 32(23): Cheng JS, Liu F, Komistek RD, Mahfouz MR, Sharma A, Glaser D: Comparison of Cervical Spine Kinematics Using a Fluoroscopic Model for Adjacent Segment Degeneration. J Neurosurg Spine 2007 Nov; 7(5): Dennis DA, Komistek RD, Mahfouz MR, Outten JT, Sharma A: Mobile Bearing Total Knee Arthroplasty. Do the Polyethylene Bearings Rotate? Clin Orthop Relat Res 2005 Nov; 440: CONFERENCE PRESENTATIONS In vivo Contact Stresses of TKA. The Zimmer Arthroplasty Course, Nashville, TN, Komistek RD, Sharma A, Ranawat CS, Mahfouz MR, Dennis DA. In vivo Determination of Contact Stresses for Subjects Implanted with a Posterior Stabilized TKA. The Knee Society, Jackson Hole, WY, Sharma A, Kubo M, Komistek RD. Mathematical Determination of Optimal Cam/Post Position and Location of Axial Rotation in the PFC Sigma RP Posterior-Stabilized Total Knee Arthroplasty. ISTA, Rome, Italy, Sharma A, Komistek RD, Ranawat CS, Mahfouz MR, Dennis DA. In vivo Determination for Subjects Implanted with a Posterior Stabilized TKA. ISTA, Rome, Italy, 2004 Sharma A, Komistek RD, Ranawat CS, Dennis DA, Mahfouz MR. In vivo Contact Pressures in Total Knee Arthroplasty. ISTA, Kyoto, Japan, Sharma A, Komistek RD, Outten JS, D Lima DD, Colwell CR Jr. In vivo Quantification of the Effect of Slip and Friction at the Knee Joint. ISTA, New York, NY, 2006 Leszko F, Sharma A, Komistek RD, Cates HE, Scuderi GR. Comparison of High Flexion TKA Patellofemoral Kinematics. ISTA, New York, NY, Sharma A, Komistek RD, Dennis D, Ranawat CS, Scuderi GR, Liu F. Kinetic Performance between Traditional and High Flexion TKA. ISTA, New York, NY, Sharma A, Komistek RD, Mahfouz MR, D Lima DD, Colwell CR Jr. Comparison of Femoro- Tibial Force Obtained from Telemetry and Mathematical Modeling. 5th World Congress of Biomechanics, Munich, Germany, Sharma A, Komistek RD, Ranawat CS, Dennis DA, Mahfouz MR. In vivo Performance Comparison between Mobile and Fixed Total Knee Arthroplasty. 52nd ORS Annual Meeting, Chicago, IL, Scuderi G, Komistek RD, Dennis DA, Ranawat CS, Sharma A, Mahfouz MR, Liu F, Anderle M. Kinetic Performance Comparison for Traditional and High Flexion TKA. AAOS, San Diego, CA, Cheng JS, Liu F, Komistek RD, Mahfouz MR, Sharma A, Glaser D. Comparison of Cervical Spine Kinematics Using a Fluoroscopic Model for Adjacent Segment Degeneration. AANS/CNS Section, Phoenix, AR, Sharma A, Komistek RD, Scuderi GR, Cates HE, Longenecker SL, Liu F. In vivo Contact Areas and Stresses for Multiple TKA Types. ISTA, Paris, France, Sharma A, Komistek RD, Hernigou P, Mahfouz MR, Anderle MR and Wang X. In vivo Kinematic Comparison for Subjects Having Both Cruciate Ligaments versus Those Using a PS TKA. ISTA 20th Annual Congress, Paris, France, Adrija Sharma, page 2

3 Dennis DA, Sharma A, Komistek RD, Mahfouz MR, Anderle MR, Little CR, Liu F. Kinematic Difference between Subjects Having Low and High Flexion at the Same Flexion Angle: A Multi- Center Study. ISTA 20th Annual Congress, Paris, France, 2007 Liu F, Komistek RD, Cheng JS, Mahfouz MR, Sharma A, Glaser D. Three-Dimensional in Vivo Contact Force Determination of Normal, Fused, and Degenerative Cervical Spines. ISTA 20th Annual Congress, Paris, France, Cheng JS, Liu F, Komistek RD, Mahfouz MR, Sharma A, Glaser D. Determination of in Vivo Three-Dimensional Motion of the Cervical Spine under Variable Conditions. ISTA 20th Annual Congress, Paris, France, Sharma A, Komistek RD, Dennis DA, Little CR: Kinematics of High versus Low Flexing Total Knee Arthroplasty. Knee Society Interim Meeting, Denver, CO, Sharma A, Dennis DA, Komistek RD, Mahfouz MR: Kinematic Difference Between Subjects having Low Flexion and High Flexion for the same Flexion Angles: A Multicenter Study. 54th ORS Annual Meeting, San Francisco, CA, 2008 Zindge SM, Sharma A, Komistek RD, Dennis DA, Mahfouz MR. In vivo Comparison of Axial Rotation for 2000 Non-Implanted and Implanted Knees. 55th ORS Annual Meeting, Las Vegas, NV, Dennis DA, Komistek RD, Kim RH, Sharma A. Balanced Resection vs Measured Resection: The clinical importance of Soft-Tissue Balancing During TKA. 22nd Annual Congress of the International Society for Technology in Arthroplasty. Big Island, HI, September, RL Lebow, O Adogwa, SL Parker, A Sharma, JS Cheng, MJ McGirt. Same-level Recurrent Disc Herniation after Lumbar Discectomy: Results of a Prospective Cohort Study with 2-Year Serial Imaging. North American Spine Society 2010 Annual Meeting, Orlando, FL. Oct. 5-9, Sharma A, Komistek RD. Variation of Femoro-Tibial Contact Force with Knee Flexion. Podium presentation. 24th Annual Congress of the International Society for Technology in Arthroplasty. Brugge, Belgium, September, Dressler M, Leszko F, Zingde S, Sharma A, Dennis D, Komistek R. Wear Simulation of a Fluoroscopic-Derived Activity of Daily Living. 24th Annual Congress of the International Society for Technology in Arthroplasty. Brugge, Belgium, September, Mueller JK, Sharma A, Komistek R, Meccia B. The Development of a Predictive Physiological Model of the Knee. 24th Annual Congress of the International Society for Technology in Arthroplasty. Brugge, Belgium, September, Meccia B, Spencer E, Zingde S, Sharma A, Leszko F, Mahfouz M, Komistek R. Real-Time Mechanics of Native Shoulders and Total Shoulder Arthroplasties. 24th Annual Congress of the International Society for Technology in Arthroplasty. Brugge, Belgium, September, Carr C, Cheng J, Sharma A, Mahfouz M, Komistek R. Impact of Low Back Pain and Degeneration on the Coupled Out-Of-Plane Rotations in the Lumbar Spine.. 24th Annual Congress of the International Society for Technology in Arthroplasty. Brugge, Belgium, September, Komistek RD, Dennis DA, Sharma A, Mahfouz MR, Anderle M. Abnormal Axial Rotation Patterns Contributes to Reduced weight Bearing Flexion. Knee Society Members Meeting, Garden City, NY, Mahfouz MR, Dennis DA, Sharma A, Komistek RD, Zingde S. Femoral Condylar Contact Points Start and Remain Posterior in High Flexing Patients. Knee Society Members Meeting, Garden City, NY, Zingde S, Leszko F, Sharma A, Mahfouz MR, Komistek RD and Dennis DA. In vivo determination of cam-post engagement in fixed and mobile bearing TKA. Knee Society Members Meeting, Garden City, NY, Adrija Sharma, page 3

4 Zingde S, Leszko F, Sharma A, Grieco T, Mahfouz MR, Dennis DA, Komistek RD. 3D in vivo Patellofemoral Kinematics for Implanted and Non-Implanted Knee. International Society for Technology in Arthroplasty, Sydney, Australia, October, Nakamura S, Komistek R, Kobayashi M, Ito H, Nakamura K, Sharma A, Zingde S. 3D in vivo Femoro-Tibial Kinematics of the Bi-Surface Total Knee System during Kneeling Activities. International Society for Technology in Arthroplasty, Sydney, Australia, October, Carr C, Sharma A, Smith J, Cheng J, Mahfouz M, Komistek, R. A Computational Model to Determine Vertebral Joint Forces in the Implanted and Non-Implanted Lumbar Spine. International Society for Technology in Arthroplasty, Sydney, Australia, October, Wong, C., Carr, C., Sharma, A., Mahfouz, M., Komistek, R., Cheng, J. Altered spinal motion in low back pain associated with lumbar strain and spondylosis. Scientific Session: Mechanobiological study of the intervertebral. Global Spine Congress, Hong Kong, April Komistek R, Hamel W, Young M, Zeller I, Grieco T, Sharma A. In vivo Kinematics of the Knee using Both Stationary and Mobile Fluoroscopy. International Society for Technology in Arthroplasty, Florida, USA, October, Nicholson GP, Komistek RD, Mahfouz MR, Hamel W, Sharma A. In vivo Dynamics of Normal, Rotator Cuff Deficient, Total and Reverse Replacement Shoulders. - Exhibit, AAOS, Washington D.C., Scientific Exhibit Award of Excellence. Sharma A, Komistek RD, Mahfouz MR, Ranawat CS, Dennis DA. In vivo Determination of Contact Pressures for Fixed and Mobile Bearing TKA. - Scientific Exhibit SE 34, AAOS, Chicago, IL, Liu F, Komistek RD, Cheng JS, Mahfouz MR, Furmanski T, Sharma A. In vivo Three- Dimensional Quantification of Kinetic Characteristics in the Normal, Degenerative and Fused Cervical Spines. - Science Exhibit, AAOS, San Diego, CA, JS Cheng, F Liu, RD Komistek, MR Mahfouz, A Sharma, DA Glaser. Normal, Fused and Degenerative Cervical Spines: A Comparative Study of 3D In Vivo Kinetics. American Academy of Orthopaedic Surgeons 2008 Annual Meeting, San Francisco, CA Mar 5-9, Sharma A, Dennis DA, Komistek RD, Mahfouz MR, Anderle M, Little CS. Kinematic Difference between Subjects Having Low and High Flexion for the Same Flexion Angles. Scientific Exhibit 18, 76th AAOS Annual Meeting, Las Vegas, NV, Zindge SM, Sharma A, Komistek RD. In vivo Comparison of Kinematics for 2000 Non- Implanted and Implanted Knees. Scientific Exhibit 22, 76th AAOS Annual Meeting, Las Vegas, NV, Liu F, Cheng JS, Komistek RD, Mahfouz MR, Sharma A. In vivo Evaluation of Dynamic Characteristics of the Normal, Degenerative, Fused and Disc Replacement Cervical Spines. - Poster, ORS, San Diego, CA, Dennis DA, Sharma A, Komistek RD, Anderle M, Little C. Kinematics of High versus Low Flexing Total Knee Arthroplasty. Poster, AAHKS, Dallas, TX, 2008 Zingde SM, Sharma A, Komistek RD, Dennis DA, Mahfouz MR. In vivo Comparison of Anterior/Posterior Translation for 2000 Knees Having Various TKA Designs. Poster, 55th ORS Annual Meeting, Las Vegas, NV, Dennis DA, Komistek RD, Kim RH, Sharma A. Stability of Total Knee Arthroplasty Performed Using Measured Resection versus Gap Balancing Methods. Poster, 55th ORS Annual Meeting, Las Vegas, NV, Sharma A, Komistek RD. Spring Network Contact Model for Non-Linear 3D Analysis of TKA Mechanics. Poster, 22nd Annual Congress of the International Society for Technology in Arthroplasty, Big Island, HI, Carr, C., Cheng, J., Sharma, A., Komistek, R.D., Mahfouz, M., Mitchell, J., Little, C. In vivo Kinematics between Pre-operative and Post-operative Fusion of the Lumbar Spine. Poster, 78th Adrija Sharma, page 4

5 Annual Meeting of the American Academy of Orthopaedic Surgeons. San Diego, CA, February Carr, C., Cheng, J., Komistek, R., Mahfouz, M., Sharma, A., Little, C. Is Fusion of the Lumbar Spine an Effective Procedure for Restoring More Normal Kinematics? 57th Annual Meeting of the Orthopaedic Research Society. Long Beach, CA. January Mueller JK, Sharma A, Komistek RD. The validation of a predictive physiological model of the knee. Poster, 24th Annual Congress of the International Society for Technology in Arthroplasty. Brugge, Belgium, September, Carr, C., Cheng, J., Sharma, A., Komistek, R.,Mahfouz, M. The Impact of Low Back Pain or Degeneration on the Coupled Out-of-Plane Rotations in the Lumbar Spine. Poster. Annual Meeting of the Orthopaedic Research Society, San Francisco, CA, February, Johnson, M.; Mahfouz, M.; Cheng, J.; Sharma, A.; Hagewood, C.; Komistek, R. A Method for Quantifying in vivo Kinematics of the Lumbar Spine for Differentiating Patients Exhibiting Low Back Pain. Poster. Annual Meeting of the Orthopaedic Research Society, San Francisco, CA, February, Smith J, Sharma A, Colwell C, D Lima DD Mahfouz MR, Komistek RD. Validation of TKA Contact Force Models Using Telemetric Implants. Poster, International Society for Technology in Arthroplasty, Sydney, Australia, October, Komistek, R., Dennis, D., Sharma, A., Mahfouz, M., Anderle, M. Abnormal Axial Rotation Patterns Contributes To Reduced Weight-bearing Flexion. Poster. American Academy of Orthopaedic Surgeons Annual Meeting, Chicago, IL, March Nakamura, S., Komistek, R., Kobayashi, M., Ito, H., Nakarmura, K., Sharma, A., Zingde, S., Nakamura, T. 3D in vivo Femoro-tibial Kinematics of Tri-Condylar Implant during Kneeling Activities. Poster. Annual Meeting of the Orthopaedic Research Society, San Antonio, TX, January, Sharma, A., Carr, C., Cheng, J., Mahfouz, M., Komistek R. Development of a Patient-Specific Mathematical Modeling Approach for Determination of in Vivo Lumbar Spine Loading Conditions. Poster, International Society for Technology in Arthroplasty, Florida, USA, October, Sharma, A., Komistek R. Comparison of Knee Forces Predicted From a Model with Telemetry for Various Activities. Poster, International Society for Technology in Arthroplasty, Florida, USA, October, Adrija Sharma, page 5

ATTUNE KNEE SYSTEM: SOFCAM CONTACT

ATTUNE KNEE SYSTEM: SOFCAM CONTACT ATTUNE KNEE SYSTEM: SOFCAM CONTACT Douglas A. Dennis, MD Medical Director at Porter Center for Joint Replacement Denver, Colorado Historically, sagittal plane instability following Total Knee Arthroplasty

More information

Evolution. Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee. Key Aspects

Evolution. Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee. Key Aspects Evolution Medial-Pivot Knee System The Bi-Cruciate-Substituting Knee Key Aspects MicroPort s EVOLUTION Medial-Pivot Knee System was designed to recreate the natural anatomy that is lost during a total

More information

Comparison of high-flex and conventional implants for bilateral total knee arthroplasty

Comparison of high-flex and conventional implants for bilateral total knee arthroplasty ISPUB.COM The Internet Journal of Orthopedic Surgery Volume 14 Number 1 Comparison of high-flex and conventional implants for bilateral total knee arthroplasty C Martin-Hernandez, M Guillen-Soriano, A

More information

BOOK CHAPTERS REFEREED JOURNAL ARTICLES

BOOK CHAPTERS REFEREED JOURNAL ARTICLES BOOK CHAPTERS 1. Mahfouz, Kuhn, To, The Future of Ultra Wideband Systems in Medicine: Orthopedic Surgical Navigation, Novel Applications of the UWB Technologies, Intech, ISBN: 978-953-307-324-8, 2011.

More information

In Vivo Mechanics of Cam-Post Engagement in Fixed and Mobile Bearing TKA and Vibroarthrography of the Knee Joint

In Vivo Mechanics of Cam-Post Engagement in Fixed and Mobile Bearing TKA and Vibroarthrography of the Knee Joint University of Tennessee, Knoxville Trace: Tennessee Research and Creative Exchange Doctoral Dissertations Graduate School 8-2015 In Vivo Mechanics of Cam-Post Engagement in Fixed and Mobile Bearing TKA

More information

Think isometry Feel balance

Think isometry Feel balance Think isometry Feel balance Learning from the experience of over 40 years of total knee development, Unity Knee is the latest evolution in total knee arthroplasty, unifying key design technologies with

More information

TOTAL KNEE ARTHROPLASTY (TKA)

TOTAL KNEE ARTHROPLASTY (TKA) TOTAL KNEE ARTHROPLASTY (TKA) 1 Anatomy, Biomechanics, and Design 2 Femur Medial and lateral condyles Convex, asymmetric Medial larger than lateral 3 Tibia Tibial plateau Medial tibial condyle: concave

More information

ATTUNE Knee System: Cruciate Sacrificing Fixed Bearing

ATTUNE Knee System: Cruciate Sacrificing Fixed Bearing ATTUNE Knee System: Cruciate Sacrificing Fixed Bearing Christel Wagner Knee Development Manager DePuy Synthes Joint Reconstruction INTRODUCTION: The purpose of a well functioning posterior cruciate ligament

More information

Fixed Bearing. stabilityinmotion

Fixed Bearing. stabilityinmotion Fixed Bearing stabilityinmotion BRINGING PATENTED TECHNOLOGIES TO A SEAMLESS SYSTEM, FROM PRIMARY THROUGH TO REVISION The ATTUNE Revision Fixed Bearing Knee System is a comprehensive system that is designed

More information

ATTUNE Knee System: Stability in Total Knee Replacement

ATTUNE Knee System: Stability in Total Knee Replacement ATTUNE Knee System: Stability in Total Knee Replacement Chadd Clary, PhD Staff Engineer DePuy Synthes Joint Reconstruction Young and active total knee replacement (TKR) patients demand a knee that feels

More information

Kinematics Analysis of Different Types of Prosthesis in Total Knee Arthroplasty with a Navigation System

Kinematics Analysis of Different Types of Prosthesis in Total Knee Arthroplasty with a Navigation System Showa Univ J Med Sci 29 3, 289 296, September 2017 Original Kinematics Analysis of Different Types of Prosthesis in Total Knee Arthroplasty with a Navigation System Hiroshi TAKAGI 1 2, Soshi ASAI 1, Atsushi

More information

Rotating Platform. stabilityinmotion

Rotating Platform. stabilityinmotion Rotating Platform stabilityinmotion BRINGING PATENTED TECHNOLOGIES TO A SEAMLESS SYSTEM, FROM PRIMARY THROUGH REVISION The ATTUNE Revision Rotating Platform Knee System is a comprehensive system that is

More information

Is There A Difference In Uni- And Multi-compartmental Knee Arthroplasty Kinematics?

Is There A Difference In Uni- And Multi-compartmental Knee Arthroplasty Kinematics? Is There A Difference In Uni- And Multi-compartmental Knee Arthroplasty Kinematics? Toshifumi Watanabe, MD, PhD 1, Stefan Kreuzer, MD, MS 2, Jennifer Amanda Christopher, BS 3, Michael Conditt, PhD 3, Brian

More information

C URRICULUM VITAE. 213 Perkins Hall University of Tennessee Knoxville, TN

C URRICULUM VITAE. 213 Perkins Hall University of Tennessee Knoxville, TN Mohamed Mahfouz, PhD C URRICULUM VITAE 213 Perkins Hall University of Tennessee Knoxville, TN 37996 mmahfouz@cmb.utk.edu Home: 865-777-1747 Work: 865-974-7668 Fax: 865-946-1787 EDUCATION Ph.D., 2002, Colorado

More information

Knee kinematics after TKA depends on preoperative kinematics

Knee kinematics after TKA depends on preoperative kinematics ICL #30 Achieving normal kinematics in TKA Knee kinematics after TKA depends on preoperative kinematics Tokifumi Majima, MD, PhD Dept. of Orthopedic Surgery Nippon Medical School 2017 ISAKOS, Shanghai,

More information

HIGH FLEXION IN CONTEMPORARY TOTAL KNEE DESIGN: A PRECURSOR OF UHMWPE DAMAGE? A FINITE ELEMENT STUDY

HIGH FLEXION IN CONTEMPORARY TOTAL KNEE DESIGN: A PRECURSOR OF UHMWPE DAMAGE? A FINITE ELEMENT STUDY HIGH FLEXION IN CONTEMPORARY TOTAL KNEE DESIGN: A PRECURSOR OF UHMWPE DAMAGE? A FINITE ELEMENT STUDY Orthopaedic Research Laboratories Cleveland, Ohio Edward A. Morra, M.S.M.E. A. Seth Greenwald, D.Phil.(Oxon)

More information

Correlation between Knee Kinematics and Patello-femoral Contact Pressure in Total Knee Arthroplasty

Correlation between Knee Kinematics and Patello-femoral Contact Pressure in Total Knee Arthroplasty Correlation between Knee Kinematics and Patello-femoral Contact Pressure in Total Knee Arthroplasty Takuya Konno, MD 1, Tomohiro Onodera, MD, PhD 1, Yasuhiko Kasahara, MD, PhD 1, Daisuke Takahashi 1, Norimasa

More information

BIOMECHANICAL MECHANISMS FOR DAMAGE: RETRIEVAL ANALYSIS AND COMPUTATIONAL WEAR PREDICTIONS IN TOTAL KNEE REPLACEMENTS

BIOMECHANICAL MECHANISMS FOR DAMAGE: RETRIEVAL ANALYSIS AND COMPUTATIONAL WEAR PREDICTIONS IN TOTAL KNEE REPLACEMENTS Journal of Mechanics in Medicine and Biology Vol. 5, No. 3 (2005) 469 475 c World Scientific Publishing Company BIOMECHANICAL MECHANISMS FOR DAMAGE: RETRIEVAL ANALYSIS AND COMPUTATIONAL WEAR PREDICTIONS

More information

The Knee 21 S1 (2014) S10 S14. Contents lists available at ScienceDirect. The Knee

The Knee 21 S1 (2014) S10 S14. Contents lists available at ScienceDirect. The Knee The Knee 21 S1 (2014) S10 S14 Contents lists available at ScienceDirect The Knee In vivo kinematics of medial unicompartmental osteoarthritic knees during activities of daily living Francesco Fiacchi,

More information

CURRICULUM VITAE CHRISTINE STEUBBEN HEIM Ward Drive Chesterland, OH Telephone:

CURRICULUM VITAE CHRISTINE STEUBBEN HEIM Ward Drive Chesterland, OH Telephone: EDUCATION CURRICULUM VITAE CHRISTINE STEUBBEN HEIM 12655 Ward Drive Chesterland, OH 44026 Telephone: +440 729 9274 B.Sc. (Biomedical Engineering) Case Western Reserve University, Cleveland, Ohio (1992)

More information

LEGION Total Knee System. Exceptional Durability

LEGION Total Knee System. Exceptional Durability LEGION Total Knee System Exceptional Durability How many knee systems have been lab-tested to 30 years of simulated wear? Just one: LEGION Primary Knee System with VERILAST Technology The LEGION Primary

More information

STABILITY & MOTION VS. THE PERSONA KNEE SYSTEM. The Zimmer Persona Knee

STABILITY & MOTION VS. THE PERSONA KNEE SYSTEM. The Zimmer Persona Knee STABILITY & MOTION VS. THE PERSONA KNEE SYSTEM The Zimmer Persona Knee The ATTUNE Knee System was designed to deliver stability and motion while the Zimmer Persona Knee System emphasizes the number of

More information

Tibial Base Design Factors Affecting Tibial Coverage After Total Knee Arthroplasty: Symmetric Versus Asymmetric Bases

Tibial Base Design Factors Affecting Tibial Coverage After Total Knee Arthroplasty: Symmetric Versus Asymmetric Bases Tibial Base Design Factors Affecting Tibial Coverage After Total Knee Arthroplasty: Symmetric Versus Asymmetric Bases Chadd Clary, PhD I Staff Engineer I DePuy Synthes Joint Reconstruction Daren Deffenbaugh,

More information

Estimating Total Knee Arthroplasty Joint Loads from Kinematics

Estimating Total Knee Arthroplasty Joint Loads from Kinematics Estimating Total Knee Arthroplasty Joint Loads from Kinematics Clare K. Fitzpatrick, Paul Rullkoetter. University of Denver, Denver, CO, USA. Disclosures: C.K. Fitzpatrick: None. P. Rullkoetter: 5; DePuy

More information

Publications and Presentations. B.A., Biology, University of Kansas, Lawrence, M.D., Cornell University Medical College, New York, 1979

Publications and Presentations. B.A., Biology, University of Kansas, Lawrence, M.D., Cornell University Medical College, New York, 1979 Publications and Presentations Name: James B. Grimes, M.D. Education: B.A., Biology, University of Kansas, Lawrence, 1975 M.D., Cornell University Medical College, New York, 1979 Graduate Hospital Clinical

More information

Analysis of factors affecting range of motion after Total Knee Arthroplasty

Analysis of factors affecting range of motion after Total Knee Arthroplasty IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 14, Issue 9 Ver. II (Sep. 2015), PP 01-10 www.iosrjournals.org Analysis of factors affecting range of

More information

EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE.

EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE. EXPERIENCE GPS FOR TOTAL KNEE ARTHROPLASTY DETERMINE YOUR OWN COURSE. The year 2010 marked Exactech s silver aiversary and 25 years of mobility. As a company founded by an orthopaedic surgeon and a biomedical

More information

BALANCING THE PATIENT NEED FOR FREEDOM OF MOVEMENT AND JOINT STABILITY

BALANCING THE PATIENT NEED FOR FREEDOM OF MOVEMENT AND JOINT STABILITY stabilityinmotion BALANCING THE PATIENT NEED FOR FREEDOM OF MOVEMENT AND JOINT STABILITY We began the ATTUNE Knee project with an important focus in mind: to improve patient performance. Data has shown

More information

itotal Customized POSTERIOR-STABILIZED knee replacement system

itotal Customized POSTERIOR-STABILIZED knee replacement system itotal PS Customized POSTERIOR-STABILIZED knee replacement system OUR VISION This is what we envision as the ideal total knee replacement (TKR) system: FOR THE SURGEON FOR THE PATIENT A REPRODUCIBLE PROCEDURE

More information

CLINICAL FINDINGS USING THE VERASENSE KNEE SYSTEM THE INTELLIGENT CHOICE FOR FLEXION STABILITY

CLINICAL FINDINGS USING THE VERASENSE KNEE SYSTEM THE INTELLIGENT CHOICE FOR FLEXION STABILITY CLINICAL FINDINGS USING THE VERASENSE KNEE SYSTEM THE INTELLIGENT CHOICE FOR FLEXION STABILITY TIGHT PCL Unfavorable Clinical Outcomes of an Excessively Tight PCL A tight PCL can result in excessive femoral

More information

Biomechanical Effects of Femoral Component Axial Rotation in Total Knee Arthroplasty (TKA)

Biomechanical Effects of Femoral Component Axial Rotation in Total Knee Arthroplasty (TKA) Biomechanical Effects of Femoral Component Axial Rotation in Total Knee Arthroplasty (TKA) Mohammad Kia, PhD, Timothy Wright, PhD, Michael Cross, MD, David Mayman, MD, Andrew Pearle, MD, Peter Sculco,

More information

Sasaki E 1,2, Otsuka H 2, Sasaki N 2, and Ishibashi Y 1

Sasaki E 1,2, Otsuka H 2, Sasaki N 2, and Ishibashi Y 1 Influence of osteophyte resection of the posterior femoral condyle on extension range of motion and gap balance in cruciate retaining type total knee arthroplasty. - Intraoperative evaluation using navigation

More information

Kinematic analysis of posterior-stabilized total knee arthroplasty during standing up from and sitting down on a chair

Kinematic analysis of posterior-stabilized total knee arthroplasty during standing up from and sitting down on a chair Mine et al. Journal of Orthopaedic Surgery and Research (216) 11:142 DOI 1.1186/s1318-16-482-y RESEARCH ARTICLE Open Access Kinematic analysis of posterior-stabilized total knee arthroplasty during standing

More information

Geometric variable designs of cam/post mechanisms influence the kinematics of knee implants

Geometric variable designs of cam/post mechanisms influence the kinematics of knee implants DOI 10.1007/s00167-014-3227-7 Knee Geometric variable designs of cam/post mechanisms influence the kinematics of knee implants Ali Fallahiarezoodar Mohammed Rafiq Abdul Kadir Mina Alizadeh Sangeetha Vasudevaraj

More information

Kinematic vs. mechanical alignment: What is the difference?

Kinematic vs. mechanical alignment: What is the difference? Kinematic vs. mechanical alignment: What is the difference? In this 4 Questions interview, Stephen M. Howell, MD, explains the potential benefits of 3D alignment during total knee replacement. Introduction

More information

Corey J. Wallach, MD The Anderson Orthopaedic Clinic 2445 Army Navy Drive Arlington, VA

Corey J. Wallach, MD The Anderson Orthopaedic Clinic 2445 Army Navy Drive Arlington, VA Corey J. Wallach, MD The Anderson Orthopaedic Clinic 2445 Army Navy Drive Arlington, VA 22206 703-769-8424 Current: Orthopedic Spine Surgeon, The Anderson Orthopaedic Clinic 2007- Present Medical Director,

More information

Zimmer Gender Solutions Natural-Knee Flex System

Zimmer Gender Solutions Natural-Knee Flex System Zimmer Natural-Knee Flex System Because Men and Women are Different Two distinct shapes for men and women. Two distinct shapes for men and women. Industry-leading technology. The proven success of the

More information

20 Kinematics of Mobile Bearing Total Knee Arthroplasty

20 Kinematics of Mobile Bearing Total Knee Arthroplasty 2 2 Kinematics of Mobile Bearing Total Knee Arthroplasty D. A. Dennis, R. D. Komistek Summary Review of the kinematic patterns of fixed- vs. mobile TKA has not demonstrated major differences, with the

More information

The challenge. Knee replacement patients report lower levels of satisfaction versus hip replacement patients. Return to sports activity post surgery

The challenge. Knee replacement patients report lower levels of satisfaction versus hip replacement patients. Return to sports activity post surgery The challenge Knee replacement patients report lower levels of satisfaction versus hip replacement patients. Return to sports activity post surgery THA 52% Post-op TKA 42% Preop 36% Preop 34% Post-op Total

More information

Presented By Dr Vincent VG An MD BSc (Adv) MPhil Dr Murilo Leie MD Mr Joshua Twiggs BEng Dr Brett A Fritsch MBBS FRACS (Orth) FAOrthA.

Presented By Dr Vincent VG An MD BSc (Adv) MPhil Dr Murilo Leie MD Mr Joshua Twiggs BEng Dr Brett A Fritsch MBBS FRACS (Orth) FAOrthA. A comparison of kinematic and mechanical alignment with regards to bony resection, soft tissue release, and deformity correction in total knee replacement Presented By Dr Vincent VG An MD BSc (Adv) MPhil

More information

Newer designs in Knee replacement The good,bad & ugly! Dr VAIBHAV BAGARIA

Newer designs in Knee replacement The good,bad & ugly! Dr VAIBHAV BAGARIA Newer designs in Knee replacement The good,bad & ugly! Dr VAIBHAV BAGARIA MBBS, MS, FCPS, DIP SICOT. Arthroplasty fellow- USA, Germany, Aus Joint replacement surgeon COLUMBIA ASIA HOSPITAL, GZB. Fresh

More information

why bicompartmental? A REVOLUTIONARY ALTERNATIVE TO TOTAL KNEE REPLACEMENTS

why bicompartmental? A REVOLUTIONARY ALTERNATIVE TO TOTAL KNEE REPLACEMENTS why bicompartmental? A REVOLUTIONARY ALTERNATIVE TO TOTAL KNEE REPLACEMENTS TKR is not always the answer Today, many patients with medial or lateral disease and patellofemoral involvement receive a Total

More information

ANDREW K. SIMPSON, MD, MHS

ANDREW K. SIMPSON, MD, MHS Andrew K. Simpson, MD, MHS 1 ANDREW K. SIMPSON, MD, MHS EDUCATION Fellowship 2013-2014 Residency 2009-2013 Internship 2008-2009 Medical School 2003-2008 Graduate School 2006-2007 Undergraduate 1999-2003

More information

Advantages of Mobile-bearing Total Knee Arthroplasty

Advantages of Mobile-bearing Total Knee Arthroplasty Advantages of Mobile-bearing Total Knee Arthroplasty a report by Douglas A Dennis, MD Clinical Director, Rocky Mountain Musculoskeletal Research Laboratory, Denver Early historical failure of total knee

More information

A study of functional outcome after Primary Total Knee Arthroplasty in elderly patients

A study of functional outcome after Primary Total Knee Arthroplasty in elderly patients Original Research Article A study of functional outcome after Primary Total Knee Arthroplasty in elderly patients Ragesh Chandran 1*, Sanath K Shetty 2, Ashwin Shetty 3, Bijith Balan 1, Lawrence J Mathias

More information

Distal femoral condyle is more internally rotated to the patellar tendon at 90 of flexion in normal knees

Distal femoral condyle is more internally rotated to the patellar tendon at 90 of flexion in normal knees Kawahara et al. Journal of Orthopaedic Surgery and Research (2015) 10:54 DOI 10.1186/s13018-015-0197-5 RESEARCH ARTICLE Open Access Distal femoral condyle is more internally rotated to the patellar tendon

More information

Frontal Plane Kinematics After Mobile- Bearing Total Knee Arthroplasty

Frontal Plane Kinematics After Mobile- Bearing Total Knee Arthroplasty CLINICAL ORTHOPAEDICS AND RELATED RESEARCH Number 392, pp. 56 61 2001 Lippincott Williams & Wilkins, Inc. Frontal Plane Kinematics After Mobile- Bearing Total Knee Arthroplasty James B. Stiehl, MD*; Richard

More information

Gold standard of a TKA. Conflicting goals? POLYETHYLENE WEAR THE SOLUTION: MOBILE BEARING KNEES. MOBILE BEARING A totally new approach (1977)

Gold standard of a TKA. Conflicting goals? POLYETHYLENE WEAR THE SOLUTION: MOBILE BEARING KNEES. MOBILE BEARING A totally new approach (1977) Changing designs : the case against mobile bearing? Gold standard of a TKA Goal of a TKA: 1. Pain 2. Motion 3. Longevity Stress Guy BELLIER M.D. PARIS France Conformity = Durability w/o constraints = non

More information

Bicruciate-Retaining or Medial Pivot Total Knee Prosthesis Pritchett 225 Fig. 3. The MP total knee prosthesis. Fig. 1. An anteroposterior radiograph o

Bicruciate-Retaining or Medial Pivot Total Knee Prosthesis Pritchett 225 Fig. 3. The MP total knee prosthesis. Fig. 1. An anteroposterior radiograph o The Journal of Arthroplasty Vol. 26 No. 2 2011 Patients Prefer A Bicruciate-Retaining or the Medial Pivot Total Knee Prosthesis James W. Pritchett, MD, FACS Abstract: Four-hundred forty patients underwent

More information

Preliminary measurements of lumbar spine kinematics and stiffness

Preliminary measurements of lumbar spine kinematics and stiffness 5 th Australasian Congress on Applied Mechanics, ACAM 2007 10-12 December 2007, Brisbane, Australia Preliminary measurements of lumbar spine kinematics and stiffness L. Jirková 1, Z. Horák 1, R. Sedláek

More information

Direct Measurement of Graft Tension in Anatomic Versus Non-anatomic ACL Reconstructions during a Dynamic Pivoting Maneuver

Direct Measurement of Graft Tension in Anatomic Versus Non-anatomic ACL Reconstructions during a Dynamic Pivoting Maneuver Direct Measurement of Graft Tension in Anatomic Versus Non-anatomic ACL Reconstructions during a Dynamic Pivoting Maneuver Scott A. Buhler 1, Newton Chan 2, Rikin Patel 2, Sabir K. Ismaily 2, Brian Vial

More information

EMPOWERING LIFE THROUGH NATURAL MOTION

EMPOWERING LIFE THROUGH NATURAL MOTION EMPOWERING LIFE THROUGH NATURAL MOTION em pow r əm pou(ə)r/ verb make (someone) stronger and more confident, especially in controlling their life and claiming their rights. WHY NATURAL MOTION? Today s

More information

STIFFNESS AFTER TKA PRE, PER AND POST OPERATIVE CAUSING FACTORS

STIFFNESS AFTER TKA PRE, PER AND POST OPERATIVE CAUSING FACTORS STIFFNESS AFTER TKA PRE, PER AND POST OPERATIVE CAUSING FACTORS Patrick DJIAN INTRODUCTION Stiffness is one of the most common complications following TKR, causing frustration to both the surgeon and the

More information

2015 Duplantier N, McCulloch P. Orthobullets Sports Medicine Technique Guide: Meniscectomy.

2015 Duplantier N, McCulloch P. Orthobullets Sports Medicine Technique Guide: Meniscectomy. Neil L. Duplantier M.D. Orthopaedic Surgeon Sports Medicine, Arthroscopy, and Cartilage Surgery PUBLICATIONS & PESENTATIONS Publications: Online Publications: 2015 Duplantier N, McCulloch P. Orthobullets

More information

An Advanced 3D Multi-Body System Model for the Human Lumbar Spine

An Advanced 3D Multi-Body System Model for the Human Lumbar Spine An Advanced 3D Multi-Body System Model for the Human Lumbar Spine Sousa, S. 1 and Claro, J. C. P. 2 1 University of Minho, Portugal, e-mail: sofia_sts@hotmail.com 2 University of Minho, Portugal, e-mail:

More information

Int J Clin Exp Med 2018;11(2): /ISSN: /IJCEM Yi Yang, Hao Liu, Yueming Song, Tao Li

Int J Clin Exp Med 2018;11(2): /ISSN: /IJCEM Yi Yang, Hao Liu, Yueming Song, Tao Li Int J Clin Exp Med 2018;11(2):1278-1284 www.ijcem.com /ISSN:1940-5901/IJCEM0063093 Case Report Dislocation and screws pull-out after application of an Isobar TTL dynamic stabilisation system at L2/3 in

More information

Is patella eversion during total knee arthroplasty crucial for gap adjustment and soft-tissue balancing?

Is patella eversion during total knee arthroplasty crucial for gap adjustment and soft-tissue balancing? Orthopaedics & Traumatology: Surgery & Research (2011) 97, 287 291 ORIGINAL ARTICLE Is patella eversion during total knee arthroplasty crucial for gap adjustment and soft-tissue balancing? G. Kamei a,,

More information

The Coflex vs. Fusion U.S. I.D.E. Trial An in vivo Biomechanical Study of Adjacent Segment Motion following Fusion

The Coflex vs. Fusion U.S. I.D.E. Trial An in vivo Biomechanical Study of Adjacent Segment Motion following Fusion The Coflex vs. Fusion U.S. I.D.E. Trial An in vivo Biomechanical Study of Adjacent Segment Motion following Fusion W.R. Sears 1, R.J. Davis 2, J.D. Auerbach 3 1 Wentworth Spine Clinic, Sydney, Australia,

More information

CURRICULUM VITAE HERBERT S. GATES, III, M.D., P.A. 681 Goodlette Road North Suite 220 Naples, Florida

CURRICULUM VITAE HERBERT S. GATES, III, M.D., P.A. 681 Goodlette Road North Suite 220 Naples, Florida CURRICULUM VITAE HERBERT S. GATES, III, M.D., P.A. 681 Goodlette Road North Suite 220 Naples, Florida 34102 239-263-4511 UNDERGRADUATE EDUCATION: Boston University School for the Arts, Boston Massachusetts

More information

Full Function, Faster Medial-Pivot

Full Function, Faster Medial-Pivot Full Function, Faster Medial-Pivot Total Knee Replacement Patient Brochure Does your knee prevent you from performing and enjoying everyday activities? Osteoarthritis affects nearly 350 million people

More information

Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing

Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing Journal of Orthopaedic Surgery 2001, 9(1): 45 50 Bilateral total knee arthroplasty: One mobile-bearing and one fixed-bearing KY Chiu, TP Ng, WM Tang and P Lam Department of Orthopaedic Surgery, The University

More information

Quality of Life. Quality of Motion.

Quality of Life. Quality of Motion. Quality of Life. Quality of Motion. Lateral Bend Vertical Translation Flexion Extension Lateral Translation Axial Rotation Anterior Posterior Translation Motion in all Directions Kinematics is the study

More information

Effects of Variation in Surgical Technique on Range of Motion in Total Knee Replacement

Effects of Variation in Surgical Technique on Range of Motion in Total Knee Replacement 1 Effects of Variation in Surgical Technique on Range of Motion in Total Knee Replacement Dipnil Chowdhury, Ronald E. McNair Scholar, Penn State University Dr. Stephen J. Piazza Department of Kinesiology,

More information

A Kinematic Assessment of Knee Prosthesis from Fluoroscopy Images

A Kinematic Assessment of Knee Prosthesis from Fluoroscopy Images Memoirs of the Faculty of Engineering, Kyushu University, Vol. 68, No. 1, March 2008 A Kinematic Assessment of Knee Prosthesis from Fluoroscopy Images by Mohammad Abrar HOSSAIN *, Michihiko FUKUNAGA and

More information

Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty

Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty Contact stress at the post-cam mechanism in posterior-stabilised total knee arthroplasty K. Nakayama, S. Matsuda, H. Miura, H. Higaki, K. Otsuka, Y. Iwamoto From Kyushu University, Fukuoka, Japan We measured

More information

MARK A. YAFFE, MD BOARD-CERTIFIED ORTHOPEDIC SURGEON HAND TO SHOULDER SPECIALIST

MARK A. YAFFE, MD BOARD-CERTIFIED ORTHOPEDIC SURGEON HAND TO SHOULDER SPECIALIST MARK A. YAFFE, MD BOARD-CERTIFIED ORTHOPEDIC SURGEON HAND TO SHOULDER SPECIALIST CURRENT EMPLOYMENT 2014-present Barrington Orthopedic Specialists, Schaumburg, Illinois Board-Certified Orthopaedic Surgeon,

More information

Editorial Manager(tm) for Clinical Orthopaedics and Related Research Manuscript Draft

Editorial Manager(tm) for Clinical Orthopaedics and Related Research Manuscript Draft Editorial Manager(tm) for Clinical Orthopaedics and Related Research Manuscript Draft Manuscript Number: Title: The Flexion Lateral Radiograph in the Evaluation of Total Knee Arthroplasty Article Type:

More information

J. Rafe Sales, MD Specializing in Spine Surgery and Reconstruction Board Certified, Orthopaedic Spine Surgery

J. Rafe Sales, MD Specializing in Spine Surgery and Reconstruction Board Certified, Orthopaedic Spine Surgery J. Rafe Sales, MD Specializing in Spine Surgery and Reconstruction Board Certified, Orthopaedic Spine Surgery 9155 SW Barnes Road, Suite 210 Phone (503) 546-3503 Fax (503) 546-3507 www.summitspinesurgery.com

More information

Finite Element Analysis of a Novel High Flexion Knee (Ti UHMWPE) used in Total Knee Arthroplasty

Finite Element Analysis of a Novel High Flexion Knee (Ti UHMWPE) used in Total Knee Arthroplasty ISPUB.COM The Internet Journal of Bioengineering Volume 4 Number 1 Finite Element Analysis of a Novel High Flexion Knee (Ti UHMWPE) used in Total Knee Arthroplasty S Sivarasu, M Lazar Citation S Sivarasu,

More information

CURRICULUM VITAE. Ohio Wesleyan University, Delaware, OH, B.A., l968. Ohio State University, College of Medicine, Columbus, OH, MD, l973

CURRICULUM VITAE. Ohio Wesleyan University, Delaware, OH, B.A., l968. Ohio State University, College of Medicine, Columbus, OH, MD, l973 CURRICULUM VITAE Name: Date and Place of Birth: Citizenship: Marital Status: Education: JAMES B. RECTOR, MD Jan. 31, 1946, Cincinnati, OH USA Married (Susan) Ohio Wesleyan University, Delaware, OH, B.A.,

More information

SANFORD H. DAVNE, M.D. CURRICULUM VITAE UPDATED 9/2006

SANFORD H. DAVNE, M.D. CURRICULUM VITAE UPDATED 9/2006 SANFORD H. DAVNE, M.D. CURRICULUM VITAE UPDATED 9/2006 ADDRESS: (O) 100 North Presidential Boulevard, 3 rd Floor Bala Cynwyd, PA 19004 610.664.2100 Cell 610.213.0287 Fax 610.647.2270 sdavne@dvosc.com (H)

More information

Stephen R Smith Northeast Nebraska Orthopaedics PC. Ligament Preserving Techniques in Total Knee Arthroplasty

Stephen R Smith Northeast Nebraska Orthopaedics PC. Ligament Preserving Techniques in Total Knee Arthroplasty Stephen R Smith Northeast Nebraska Orthopaedics PC Ligament Preserving Techniques in Total Knee Arthroplasty 10-15% have Fair to poor Results? Why? The complication rate is 2.567% If It happens To You

More information

ConforMIS, Inc. 28 Crosby Drive Bedford, MA Phone: Fax:

ConforMIS, Inc. 28 Crosby Drive Bedford, MA Phone: Fax: ConforMIS, Inc. 28 Crosby Drive Bedford, MA 01730 Phone: 781.345.9001 Fax: 781.345.0147 www.conformis.com 0086 Authorized Representative: Medical Device Safety Service, GMBH Schiffgraben 41, 30175 Hannover,

More information

Quality of Life. Quality of Motion. A Patient s Guide to. Artificial Lumbar Disc Replacement

Quality of Life. Quality of Motion. A Patient s Guide to. Artificial Lumbar Disc Replacement Quality of Life. Quality of Motion. A Patient s Guide to Artificial Lumbar Disc Replacement Each year, hundreds of thousands of adults are diagnosed with Lumbar Disc Degeneration, a lower spine condition

More information

CURRICULUM VITAE. Illinois Bone and Joint Institute 2004-Present. Diplomate, American Board of Orthopaedic Surgery Certified 7/2006

CURRICULUM VITAE. Illinois Bone and Joint Institute 2004-Present. Diplomate, American Board of Orthopaedic Surgery Certified 7/2006 CURRICULUM VITAE Alexander C. Gordon, M.D. Illinois Bone and Joint Institute 9000 Waukegan Rd Morton Grove, IL 60053 (847)-375-3000 agordon@ibji.com Occupation Certification Licensure Hospital Affiliations

More information

The KineSpring Knee Implant System Product Information

The KineSpring Knee Implant System Product Information The KineSpring Knee Implant System Product Information The Treatment Gap Increasing numbers of young, active OA patients with longer life expectancy and higher activity demands. 1 Large increase in arthroplasty

More information

ORIGINAL PAPER. Department of Orthopedic Surgery,Nagoya University Graduate School of Medicine,Nagoya,Japan 2

ORIGINAL PAPER. Department of Orthopedic Surgery,Nagoya University Graduate School of Medicine,Nagoya,Japan 2 Nagoya J. Med. Sci. 80. 583 589, 2018 doi:10.18999/nagjms.80.4.583 ORIGINAL PAPER Evaluation of sagittal alignment and range of motion of the cervical spine using multi-detector- row computed tomography

More information

SAIPH Knee System. Clinical Data Summary. Physiological Stability and Mobility for the Active Knee Without Compromise

SAIPH Knee System. Clinical Data Summary. Physiological Stability and Mobility for the Active Knee Without Compromise SAIPH Knee System Clinical Data Summary Physiological Stability and Mobility for the Active Knee Without Compromise Contents Section 1 Summary overview of clinical data 3 Section 2 Key SAIPH literature

More information

Rotaglide+ TM. Total Knee System Product overview

Rotaglide+ TM. Total Knee System Product overview Rotaglide+ TM Total Knee System Product overview Rotaglide+ TM Originality Stability History Originally implanted in 1988, Rotaglide+ was the first total knee design to adopt a true mobile bearing philosophy.

More information

Midterm results of cemented Press Fit Condylar Sigma total knee arthroplasty system

Midterm results of cemented Press Fit Condylar Sigma total knee arthroplasty system Journal of Orthopaedic Surgery 2005:13(3):280-284 Midterm results of cemented Press Fit Condylar Sigma total knee arthroplasty system S Asif, DSK Choon Department of Orthopaedic Surgery, University of

More information

Zimmer FuZion Instruments. Surgical Technique (Beta Version)

Zimmer FuZion Instruments. Surgical Technique (Beta Version) Zimmer FuZion Surgical Technique (Beta Version) INTRO Surgical Technique Introduction Surgical goals during total knee arthroplasty (TKA) include establishment of normal leg alignment, secure implant fixation,

More information

DATA & RESEARCH OVERVIEW

DATA & RESEARCH OVERVIEW DATA & RESEARCH OVERVIEW Total knee arthroplasty helps to relieve pain and restore function and mobility for arthritis pain sufferers and is widely recognized as one of the most performed and successful

More information

Posterior cruciate ligament retaining versus posterior cruciate ligament substituting knee arthroplasties: a four-decades-old debate

Posterior cruciate ligament retaining versus posterior cruciate ligament substituting knee arthroplasties: a four-decades-old debate Page 1 of 5 Trauma & Orthopaedics Posterior cruciate ligament retaining versus posterior cruciate ligament substituting knee arthroplasties: a four-decades-old debate NP Sachinis* *Corresponding author

More information

Rotating Platform System. Product Rationale

Rotating Platform System. Product Rationale References 1. Meftah M, Ranawat A, Ranawat C. Ten-Year Follow-up of a Rotating-Platform, Posterior-Stabilised Total Knee Arthroplasty. J Bone Joint Surg Am. 2012; 94:426-32 2. Dalury D, Gonzales R, Adams

More information

SAMUEL C. WORDEMAN, Ph.D. PROFESSIONAL BIOGRAPHICAL OUTLINE

SAMUEL C. WORDEMAN, Ph.D. PROFESSIONAL BIOGRAPHICAL OUTLINE SAMUEL C. WORDEMAN, Ph.D. PROFESSIONAL BIOGRAPHICAL OUTLINE BACKGROUND Dr. Wordeman earned a Bachelor of Science degree in Biomedical Engineering with a focus in Biomechanics from Washington University

More information

Mid-term Results of Total Knee Arthroplasty Using PFC Sigma RP-F

Mid-term Results of Total Knee Arthroplasty Using PFC Sigma RP-F Original Article Knee Surg Relat Res 2012;24(4):221-226 http://dx.doi.org/10.5792/ksrr.2012.24.4.221 pissn 2234-0726 eissn 2234-2451 Knee Surgery & Related Research Mid-term Results of Total Knee Arthroplasty

More information

Lumbar Facet Joint Replacement

Lumbar Facet Joint Replacement Rome Spine 2011 THE SPINE TODAY International Congress Rome 6-7th December 2011 Lumbar Facet Joint Replacement Prof. Dr. Karin Büttner-Janz Past President International Society for the Advancement of Spine

More information

Joint Line Elevation in Revision TKA Leads to Increased Patellofemoral Contact Forces

Joint Line Elevation in Revision TKA Leads to Increased Patellofemoral Contact Forces Joint Line Elevation in Revision TKA Leads to Increased Patellofemoral Contact Forces Christian König, Alexey Sharenkov, Georg Matziolis, William R. Taylor, Carsten Perka, Georg N. Duda, Markus O. Heller

More information

Where Is the Natural Internal-External Rotation Axis of the Tibia?

Where Is the Natural Internal-External Rotation Axis of the Tibia? Where Is the Natural Internal-External Rotation Axis of the Tibia? Daniel Boguszewski 1, Paul Yang 2, Nirav Joshi 2, Keith Markolf 1, Frank Petrigliano 1, David McAllister 1. 1 University of California

More information

THE KNEE SOCIETY VIRTUAL FELLOWSHIP

THE KNEE SOCIETY VIRTUAL FELLOWSHIP THE KNEE SOCIETY VIRTUAL FELLOWSHIP CHAPTER 2: RADIOGRAPHIC EVALUATION OF THE KNEE Radiographic Evaluation of the Knee Presented by: R. Michael Meneghini, MD COPYRIGHT 2016 THE KNEE SOCIETY Disclosures

More information

The power of simplicity

The power of simplicity The power of simplicity The power of simplicity Consider the facts, and take a look at the future: Revision TKA procedures are projected to double between now and 2015. 1 Restoration of a normal joint

More information

Orthopedics, Trauma and Rheumatology

Orthopedics, Trauma and Rheumatology March 2018 Proceedings of Orthopedics, Trauma and Rheumatology Hosting Organization: Pulsus Group 40 Bloomsbury Way, Lower Ground Floor London, UK WC1A 2SE Ph: +1-408-429-2646 E-Mail: contact@cmesociety.com

More information

NexGen CR-Flex and LPS-Flex Knees. Design Rationale

NexGen CR-Flex and LPS-Flex Knees. Design Rationale NexGen CR-Flex and LPS-Flex Knees Design Rationale Table of Contents Introduction... 2 High Flexion in Activities of Daily Living... 3 Key Elements in Achieving Deep Flexion... 4 Patient Factors Surgical

More information

IN VIVO CERVICAL SPINE KINEMATICS, ARTHROKINEMATICS AND DISC LOADING IN ASYMPTOMATIC CONTROL SUBJECTS AND ANTERIOR FUSION PATIENTS.

IN VIVO CERVICAL SPINE KINEMATICS, ARTHROKINEMATICS AND DISC LOADING IN ASYMPTOMATIC CONTROL SUBJECTS AND ANTERIOR FUSION PATIENTS. IN VIVO CERVICAL SPINE KINEMATICS, ARTHROKINEMATICS AND DISC LOADING IN ASYMPTOMATIC CONTROL SUBJECTS AND ANTERIOR FUSION PATIENTS by William Anderst BS in Mechanical Engineering, University of Notre Dame,

More information

Michael Finnegan Shepard M.D.

Michael Finnegan Shepard M.D. Michael Finnegan Shepard M.D. Professional Experience 2002-2003 Sports Fellowship - American Sports Medicine Institute James Andrews MD and William Clancy MD 1998-1999 UCLA Department of Orthopaedic Surgery

More information

Hiroto Yamaguchi*, Hidetoshi Nojiri**, Kei Miyagawa*, Nozomu Inoue***

Hiroto Yamaguchi*, Hidetoshi Nojiri**, Kei Miyagawa*, Nozomu Inoue*** Three-Dimensional High-Resolution Image Analysis of the Segmental Reduction Effect Obtained with Lateral Lumbar Interbody Fusion for Lumbar Intervertebral Deformity Hiroto Yamaguchi*, Hidetoshi Nojiri**,

More information

CURRICULUM VITAE. PERSONAL DATA Jeremy Michael Oryhon, MD.

CURRICULUM VITAE. PERSONAL DATA Jeremy Michael Oryhon, MD. PERSONAL DATA Jeremy Michael Oryhon, MD joryhon@ibji.com CURRICULUM VITAE WORK Lake Cook Orthopedic Associates (8/10/09 present) a division of Illinois Bone and Joint Institute 27401 W. Highway 22, Suite

More information

Cover Page. The handle holds various files of this Leiden University dissertation.

Cover Page. The handle  holds various files of this Leiden University dissertation. Cover Page The handle http://hdl.handle.net/1887/44484 holds various files of this Leiden University dissertation. Author: Van de Velde, S.K. Title: In vivo biomechanics of cruciate ligament injuries Issue

More information

Femoral component loosening in high-flexion total knee replacement

Femoral component loosening in high-flexion total knee replacement KNEE: RESEARCH Femoral component loosening in high-flexion total knee replacement AN IN VITRO COMPARISON OF HIGH-FLEXION VERSUS CONVENTIONAL DESIGNS P. Bollars, J.-P. Luyckx, B. Innocenti, L. Labey, J.

More information

University of Colorado, Health Sciences Center Denver, CO Physical Therapy Doctor of Physical Therapy (DPT) 2005

University of Colorado, Health Sciences Center Denver, CO Physical Therapy Doctor of Physical Therapy (DPT) 2005 Education: University of Colorado, Anschutz Medical Campus 2009-2014 Clinical Science Dissertation: Improving Rehabilitation Outcomes After Total Hip Arthroplasty Doctor of Philosophy (PhD) 2014 Certificate:

More information