1 Distal Radius Fractures: Staying Out of Trouble Brad Palmer, MD Allegheny General Hospital Pittsburgh, PA Disclosures Nothing to Disclosure in the past 12 months, neither my spouse nor myself have had a financial relationship with a commercial interest (any entity producing, marketing, re-selling, or distributing health care goods or services consumed by or used on patients; with the exception of providers of clinical service directly to patients) Epidemiology Most common fracture of UE 1/6 of all fractures in ER 74% of all forearm fractures 195.2/100,000 persons per year $164,000,000 was spent on hospitalizations related to distal radius fracture in 2007 Bimodal High energy in predominantly young males Low energy in predominantly older females 1
2 History Abraham Colles (1814) This fracture takes place at about an inch and a half above the carpal extremity of the radius The carpus and base of the metacarpus appear to be thrown backward so much as on first view, to excite a suspicion that the carpus is dislocated. Treatment Trends Trend towards ORIF Finland x increase in surgical treatment 13x increase in use of open reduction and plate fixation ASSH Members more often treated patients with ORIF vs nonmembers (33% vs 16%, P<0.001) Mattila VM, Huttunen TT, Sillanpaa P, Niemi S, Pihlajamaki H, Kannus P. Significant change in the surgical treatment of distal radius fractures: a nationwide study between 1998 and 2008 in Finland. J Trauma 2011;71: Chung KC, Shauver MJ, Yin H. The relationship between ASSH membership and the treatment of distal radius fracture in the United States Medicare population. J Hand Surg 2011;36A: AAOS Guidelines December 5, 2009 Large work group Evidence based literature review Treatment of distal radius fracture in patients older then 19 years 2
3 AAOS Guidelines 219 page document 29 recommendations 14 inconclusive Could not recommend for or against a treatment modality 6 limited Treatment modality is an option 6 moderate Suggest treatment modality based on evidence 3 consesus Not enough evidence to support a modality but the work group all agreed the modality was reasonable AAOS Recommendation We are unable to recommend for or against any one specific operative method for fixation of distal radius fractures. Inconclusive AAOS recommendation Closed reduction and percutaneous fixation vs. ORIF Non-bridging vs. bridging external fixation Augmented bridging external fixation vs. percutaneous pinning Augmented bridging external fixation vs. bridging external fixation Augmented bridging external fixation vs. plate Augmented bridging external fixation vs. volar locking plate Bridging external fixation vs. percutaneous pinning Bridging external fixation vs. medullary pinning Bridging external fixation vs. pins and plaster Dorsal locking plate vs. dual plating 3
4 ORIF Indications: shearing marginal fx of joint surface Barton s fx, reverse Barton s fx, radial styloid fx unstable, extra-articular fx complex intra-articular fx irreducible fx radiocarpal fracture-dislocation associated carpal fx ipsilateral forearm or elbow fx ORIF Volar Plating Bridge Plating Volar Plating Evolution of the blade plate Locking distal screws Fixed angle device Now many versions with fixed or variable angle distal locking screws 4
5 So many choices Limthongthang R, Bachoura A, Jacoby SM, Osterman AL. Distal Radius Volar Plate Design and Associated Vulnerability of the Flexor Pollicis Longus. J Hand Surg Am. May (5): Adverse Events Carpal tunnel syndrome Tendon ruptures Intra-articular screw protusion Loss of fixation Carpal Tunnel Symptoms 12 of 60 patients treated nonoperatively 20% 17 of 69 patients treated with volar plating 25% Griffin JW, Chhabra AB. Complications After Volar Plating of Distal Radius Fracture: An Evidence Based Review. J Hand Surg Am. June :
6 AAOS Recommendation We are unable to recommend for or against performing nerve decompression when nerve dysfunction persists after reduction. Inconclusive Volar Approach Volar Approach 6
7 Volar Approaches Eighty-three patients entered the CTR group. Thirty-one patients showed median nerve dysfunction 6 weeks after surgery. 91 patients entered the HRY group. Temporary median nerve paraesthesia was seen in 4 patients in the HRY group 6 weeks after surgery. After 1 year, persistent median nerve irritation was observed in 4 patients of the CTR group and none of the HRY group. Grip strength, range of motion, and Patient- Rated Wrist Evaluation were similar after 1 year. Lattmann T, Dietrich M,Meier C, Kilgus M. Comparison of 2 Surgical Approaches for Volar Locking Plate Osteosynthesis of the Distal Radius. Sept JHS:33: CTS after Volar Plating 10 patients Volar plate ORIF Insert slit catheters 24 hour continuous monitoring of carpal canal Fuller DA, Barrett M, Marburger RK, Hirsch R. Carpal canal pressures after volar plating of distal radius fractures. J Hand Surg Br. 2006;31(2):236e239. CTS after Volar Plating 10 patients 9 patients Pressures below 40 mmhg 1 patient 65 mmhg No patients had median nerve sypmtoms Fuller DA, Barrett M, Marburger RK, Hirsch R. Carpal canal pressures after volar plating of distal radius fractures. J Hand Surg Br. 2006;31(2):236e239. 7
8 Adverse Events Carpal tunnel syndrome Tendon ruptures Intra-articular screw protusion Loss of fixation Has been reports as high as 12% Many potential causes Previous steroid injections Plate material Plate prominence Plate/hardware placement Tendon Ruptures Soong, M., Earp, B.E., Bishop, G., Leung, A., and Blazar, P. Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am. 2011; 93: Plate Position Retrospective review 4 year period 2 Groups Compared complications Group 1: 72 patients Group 2: 93 patient Soong, M., Earp, B.E., Bishop, G., Leung, A., and Blazar, P. Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am. 2011; 93:
9 Plate Position Grade 0 Dorsal to red line Grade 1 Volar to red line but proximal to the volar rim Grade 2 Plate at the rim or beyond Soong, M., Earp, B.E., Bishop, G., Leung, A., and Blazar, P. Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am. 2011; 93: Plates at rim had more tendon ruptures Consider plate placement and design Soong, M., Earp, B.E., Bishop, G., Leung, A., and Blazar, P. Volar locking plate implant prominence and flexor tendon rupture. J Bone Joint Surg Am. 2011; 93: Volar Plate Positioning Retrospective Review Patients SP ORIF of DR with volar plate 8 patients with flexor tendon ruptures Evaluate for radiographic parameters to identify risk factors for flexor tendon ruptures Kitay A, Swanstrom M, Schreiber JJ, Carlson MG, Nguyen JT, Weiland J, Daluiski A. Volar Plate Position and Flexor Tendon Rupture Following Radius Fracture Fixation. J Hand Surg Am. 2013;38(6):
10 Volar Plate Position A The measurements of plate position and prominence are demonstrated on this facet lateral radiograph. The plate to critical line distance (PCL) is measured with negative values for plates dorsal to the critical line (like the plate in this figure) and positive values for prominent plates volar to the critical line. The plate to volar rim (PVR) distance is measured with positive numbers for plates proximal to the volar rim (as demonstrated in the figure) and negative values for plates distal to the volar rim. The facet lateral radiograph in this figure was chosen for clarity, but for analysis, all PCL and PVR measurements were made on standard lateral radiographs. B The plate is Soong grade 0 because it is both dorsal to the volar critical line and proximal to the volar rim. Soong 1: plates volar to the volar critical line (but proximal to the volar rim). Soong 2: Distal plates that extend to the level of the volar rim or beyond. Volar Plate Position Risk Factors for flexor tendon rupture following distal radius fracture fixation with volar plates. recommend considering elective hardware removal after union in symptomatic patients with plate prominence greater than 2.0 mm volar to the critical line or plate position within 3.0 mm of the volar rim. Kitay A, Swanstrom M, Schreiber JJ, Carlson MG, Nguyen JT, Weiland J, Daluiski A. Volar Plate Position and Flexor Tendon Rupture Following Radius Fracture Fixation. J Hand Surg Am. 2013;38(6): Adverse Events Carpal tunnel syndrome Tendon ruptures Intra-articular screw protusion Loss of fixation 10
11 Screw Protusion Intra-articular screws Radiocarpal degeneration Out the dorsal cortex EPL tendon ruptures Intra-articular Screws 22 o tilted lateral view Standard lateral Tilted Lateral Lundy DW, Quisling SG, Lourie GM, Feiner CM, Lins RE. Tilted Lateral Radiographs in the Evaluation of Intra-articular Distal Radius Fractures. J Hand Surg Am. March 1999:24(2): Dorsal Screw Protusion Extensor tendon ruptures Difficult to accurately evaluate on Lateral or angled lateral views 11
12 Dorsal Horizon View Joseph SJ, Harvey JN. The Dorsal Horizon View: Detecting Screw Protusion at the Distal Radius. J Hand Surg Am. Oct 2011:36(10): Lateral views can be inaccurate Need to drill the dorsal cortex? Joseph SJ, Harvey JN. The Dorsal Horizon View: Detecting Screw Protusion at the Distal Radius. J Hand Surg Am. Oct 2011:36(10):
13 Screw Length Biomechanical SawBones Study Locked unicortical distal screws of at least 75% length produce construct stiffness similar to bicortical fixation Wall LB, Brodt MD, Silva MJ, Boyer MI, Calfee RP. The Effects of Screw Length on Stability of Simulated Osteoporotic Distal Radius Fractures Fixed With Volar Locking Plates. J Hand Surg Am. March 2012:37(3): Adverse Events Carpal tunnel syndrome Tendon ruptures Intra-articular screw protusion Loss of fixation Loss of Fixation 72 year old female Slipped in the tub Volar <1cm open wound No neurologic deficits 13
14 14
15 ORIF 4 weeks postop Lunate Facet Fragment Fixation can be challenging Attachment of the volar ligaments Loss of reduction leads to loss of extension and supination Ruch, D.S., Wray, W.H. III, Papadonikolakis, A., Richard, M.J., Leversedge, F.J., and Goldner, R.D. Corrective osteotomy for isolated malunion of the palmar lunate facet in distal radius fractures. J Hand Surg Am. 2010; 35:
16 Recognition Tear drop angle Lateral view Longitudinal axis of the radius Line parallel with the subchondral bone Normal ~70 o If <45 o there is marked dorsal tilt Medoff, R.J. Essential radiographic evaluation for distal radius fractures. Hand Clin. 2005; 21: How to Fix? careful positioning of a volar plate on the ulnar-most aspect of the distal radius can allow for at least 2 points of fixation into the lunate facet fragment Volar plate fixation can also be augmented by adding a single cannulated screw with a washer to secure the lunate facet fragment Fragment-specific fixation low-profile plates wire loop fixation Kitay A, Madgal C. Volar Carpal Subluxation Following Lunate Facet Fracture. J Hand Surg Am. Nov 2014;39(11): How to Fix? 16
17 Specific Plates Specific Plates Comminuted Volar Rim 17
18 AAOS Recommendation In order to limit complications when using external fixation, it is an option to limit the duration of fixation. Limited Bridge Plating Spanning wrist plate internal external fixation Ligamentaxis Supplemental fixation High energy distal radius fractures Allow weightbearing Bridge Plating in the Elderly 33 patients (mean age, 70 y) distraction plating for comminuted distal radius fractures all fractures had healed radiographs demonstrated mean palmar tilt of 5 and mean positive ulnar variance of 0.6 mm. Mean radial inclination was 20 Mean values for wrist flexion and extension were 46 and 50, respectively. Mean pronation and supination were 79 and 77, respectively. At final follow-up, the mean DASH score was 32. Richard MJ, Katolik LI,Hanel DP, Wartinbee DA, Ruch DS. Distraction Plating for the Treatment of Highly Comminuted Distal Radius Fracture in Elderly Patients. J of Hand Surg. May 2012:37:
19 19
20 20
21 21
22 Take Home Points Volar Plating Plate Position Beware the lunate Facet fracture Dorsal Horizon View and Tilted Lateral View Bridge Plate Contact 22
Disclosures. Distal Radius Fractures 5/16/2017. Distal Radius Fractures: Complications & Limitations of the Volar Approach
Distal Radius Fractures: Complications & Limitations of the Volar Approach Frank R. Avilucea, MD Assistant Professor Department of Orthopaedic Surgery University of Cincinnati Medical Center Disclosures
More information6/5/2018. DISCLOSURES Hassan R. Mir, MD, MBA, FACS. Evolution of Distal Radius Fracture Treatment [Chung Hand Clinics 2012]
DISCLOSURES Hassan R. Mir, MD, MBA, FACS Paid Consultant for a Company or Supplier Smith & Nephew Zimmer Biomet Trice Medical Stock or Stock Options Core Orthopaedics OrthoGrid Systems Research Support
More informationDistal radius fractures
Distal radius fractures One of the most common fractures seen by orthopaedic surgeons Incidence 195.2/100,000 persons per year Significant financial burden Distal radius fractures Improved implants ORIF
More informationComplications of Distal Radius Fractures. How to Treat a Distal Radius Fx 11/13/2017. Michael S. Bednar, M.D. Loyola University Chicago
Complications of Distal Radius Fractures Michael S. Bednar, M.D. Loyola University Chicago How to Treat a Distal Radius Fx Need to restore motion, begin with uninvolved parts Need to reduce an unreduced
More informationIndex. Note: Page numbers of article titles are in boldface type. Hand Clin 21 (2005)
Hand Clin 21 (2005) 501 505 Index Note: Page numbers of article titles are in boldface type. A Antibiotics, following distal radius fracture treatment, 295, 296 Arthritis, following malunion of distal
More informationDisclosure. 85% Dorsal. 15% Volar. Distal Radius Fractures- Volar Plating for All. Skeletal Dynamics- Consultant
Distal Radius Fractures- Volar Plating for All Frontiers in Upper Extremity Surgery 2017 Francisco Rubio, M.D. Miami Hand and Upper Extremity Institute Miami, FL Disclosure Skeletal Dynamics- Consultant
More informationCommon Limb Fractures. Mr Sheraz Malik MB BS MRCS Instructor Mr Paul Ofori-Atta Mb ChB FRCS President Motc Life UK April 2009
Common Limb Fractures Mr Sheraz Malik MB BS MRCS Instructor Mr Paul Ofori-Atta Mb ChB FRCS President Motc Life UK April 2009 Objectives To be able to describe all characteristics of a fracture Describe
More informationVolar fixed-angle plating for distal radius fractures 刀圭会協立病院 津村敬
Volar fixed-angle plating for distal radius fractures 刀圭会協立病院 津村敬 Normal distal radius anatomy Radial styloid process EPL Volar lip Lister s s tubercle Radial styloid process Sigmoid notch palmar view
More informationIndex. Springer International Publishing Switzerland 2016 J.N. Lawton (ed.), Distal Radius Fractures, DOI /
Index A AAOS. See American Academy of Orthopaedic Surgeons (AAOS) Abductor pollicis longus (APL) tendon, 34, 73 Acute carpal tunnel syndrome, 93 American Academy of Orthopaedic Surgeons (AAOS), 66, 238
More informationHand and wrist emergencies
Chapter1 Hand and wrist emergencies Carl A. Germann Distal radius and ulnar injuries PEARL: Fractures of the distal radius and ulna are the most common type of fractures in patients younger than 75 years.
More informationEmile N. Brown, MD, and Scott D. Lifchez, MD
Flexor Pollicis Longus Tendon Rupture After Volar Plating of a Distal Radius Fracture: Pronator Quadratus Plate Coverage May Not Adequately Protect Tendons Emile N. Brown, MD, and Scott D. Lifchez, MD
More informationMark VanDer Kaag 1, Ajmal Ikram 2. Hand Unit, Tygerberg Hospital University of Stellenbosch
A Prospective, Randomized Controlled Study To Determine The Radiological And Functional Outcomes Of IMN Fixation Of Distal Radius Fractures Using A Novel Device The Sonoma Wrx Distal Radius Nail Compared
More informationTreatment of unstable distal radius fractures with the volar locking plate
Upsala Journal of Medical Sciences. 2011; 116: 280 284 ORIGINAL ARTICLE Treatment of unstable distal radius fractures with the volar locking plate HANAE MINEGISHI 1, OSAMU DOHI 1, SOUKAN AN 2 & HIDETSUGU
More informationThe NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are
The NBX Non-Bridging External Fixator A Non-Bridging External Fixator/Locking Plate capturing a series of.062mm K-wires and 3mm half-pins that are inserted in a multiplanar and multi-directional fashion
More informationAcu-Loc Wrist Spanning Plate System. Surgical Technique
Acu-Loc Wrist Spanning Plate System Surgical Technique Acumed is a global leader of innovative orthopaedic and medical solutions. We are dedicated to developing products, service methods, and approaches
More informationWrist Fixation System
Wrist Fixation System Anatomy / Fracture Implant EXTRA & SIMPLE ARTICULAR Volar Radius Volar Fixed Angle Plate Volar Bearing Plate Radial Peg Plate Volar Hook Plate Volar Buttress Pin Volar Shear Plate
More informationReproducibility of Three Dimensional Digital Preoperative Planning for the Osteosynthesis of Distal Radius Fractures
Reproducibility of Three Dimensional Digital Preoperative Planning for the Osteosynthesis of Distal Radius Fractures Yuichi Yoshii, 1 Takuya Kusakabe, 1 Kenichi Akita, 2 Wen Lin Tung, 3 Tomoo Ishii 1 1
More informationTechnique Guide. 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.
Technique Guide 2.4 mm Variable Angle LCP Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Table of Contents Introduction 2.4 mm Variable Angle LCP
More information5/9/2017. Distal Radius Fractures: What s New? What s New? Or Maybe New to you. Single Pak Sterile distal radius kits
Distal Radius Fractures: What s New? What s New? Or Maybe New to you. Single Pak Sterile distal radius kits Extension of FCR split to release tendon for retraction Pronator Quadratus elevation with BR
More informationMINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y.
Riv Chir Mano - Vol. 43 (3) 2006 MINIMALLY INVASIVE PLATE OSTEOSYNTHESIS FOR DISTAL RADIUS FRACTURES: SURGICAL TECHNIQUE M. TOBE 1, K. MIZUTANI 1, Y. TSUBUKU 1, Y. YANAGIHARA 2 1 Department of 2nd Orthopaedic
More informationUniversity of Groningen. Fracture of the distal radius Oskam, Jacob
University of Groningen Fracture of the distal radius Oskam, Jacob IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the document
More informationUniversity of Groningen. Fracture of the distal radius Oskam, Jacob
University of Groningen Fracture of the distal radius Oskam, Jacob IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the document
More informationCASE REPORT. Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report
Nagoya J. Med. Sci. 79. 551 ~ 557, 2017 doi:10.18999/nagjms.79.4.551 CASE REPORT Distal radius nonunion after volar locking plate fixation of a distal radius fracture: a case report Takaaki Shinohara 1
More informationClient centered approach to distal radius fracture management. Jared Rasmussen OTR
Client centered approach to distal radius fracture management Jared Rasmussen OTR Disclosures Sadly, no financial disclosures Objectives Review of anatomy, common fractures of the distal radius, fixation
More informationForearm Fracture Solutions. Product Overview
Forearm Fracture Solutions Product Overview Acumed Forearm Fracture Solutions Acumed Forearm Fracture Solutions includes plating and rodding systems with a range of diaphyseal radius and ulna fracture
More informationMICRONAIL. Intramedullary Distal Radius System SURGICAL TECHNIQUE
MICRONAIL II Intramedullary Distal Radius System SURGICAL TECHNIQUE Contents Introduction 3 4 Chapter 1 5 Chapter 2 6 Appendix A 18 Appendix B 19 Surgeon Design Team Introduction Product Information Surgical
More informationIntroduction. The wrist contains eight small carpal bones, which as a group act as a flexible spacer between the forearm and hand.
Wrist Introduction The wrist contains eight small carpal bones, which as a group act as a flexible spacer between the forearm and hand. Distal forearm Distal forearm 4 Distal end of the radius A. anterior
More informationOutcome following distally locked volar plating for distal radius fractures with metadiaphyseal involvement
HAND (2015) 10:292 296 DOI 10.1007/s11552-014-9713-z Outcome following distally locked volar plating for distal radius fractures with metadiaphyseal involvement Kristofer S. Matullo & David G. Dennison
More informationHand numbness and carpal tunnel syndrome after volar plating of distal radius fracture
HAND (2011) 6:34 38 DOI 10.1007/s11552-010-9283-7 ORIGINAL ARTICLE Hand and carpal tunnel syndrome after volar plating of distal radius fracture Angela Wing Hang Ho & S. T. Ho & S. C. Koo & K. H. Wong
More informationCase Presentation: Comminuted Fractures of the Proximal Ulna 11/28/2017. Disclosures. Surgical Strategy. Implant Choice. Melvin P.
Current Solutions in Orthopaedic Trauma Case Presentation: Comminuted Fracture of the Proximal Ulna Melvin P. Rosenwasser, MD Robert E. Carroll Professor of Surgery of the Hand Chief, Orthopaedic Hand
More informationA STUDY OF THE FUNCTIONAL OUTCOME OF LOW PROFILE DORSAL PLATING IN DISTAL END RADIUS FRACTURES
Original Article Orthopaedics A STUDY OF THE FUNCTIONAL OUTCOME OF LOW PROFILE DORSAL PLATING IN DISTAL END RADIUS FRACTURES Sunil H. Shetty 1, Amit B. Dhond 2, Manavdeep Singh 3, Atul Kharat 4, Abhimanyu
More informationjournal ORIGINAL RESEARCH
texas orthopaedic journal ORIGINAL RESEARCH Assessment of Volar Tilt Measurements with Variations in X-Ray Beam Centralization Along the Longitudinal Axis of the Radius Russell A. Wagner, MD; Will Junius,
More informationUniversity of Groningen. Fracture of the distal radius Oskam, Jacob
University of Groningen Fracture of the distal radius Oskam, Jacob IMPORTANT NOTE: You are advised to consult the publisher's version (publisher's PDF) if you wish to cite from it. Please check the document
More informationInteresting Case Series. Ulnolunate Impaction Syndrome
Interesting Case Series Ulnolunate Impaction Syndrome Saptarshi Biswas, MD, FRCS Westchester University Medical Center, Valhalla, NY Keywords: ulnar impaction, ulnar impaction syndrome, ulnar wrist pain,
More informationUnion Surgical. T-Pin. Fixation System for Distal Radius & Distal Ulna Fractures. Surgical Technique
Union Surgical T-Pin Fixation System for Distal Radius & Distal Ulna Fractures Surgical Technique 1 Table of Contents 02 The T-Pin 03 Historical Perspective 04 Indications & Contraindications 05 Surgical
More informationClinical Study Rate of Improvement following Volar Plate Open Reduction and Internal Fixation of Distal Radius Fractures
SAGE-Hindawi Access to Research Advances in Orthopedics Volume 2011, Article ID 565642, 4 pages doi:10.4061/2011/565642 Clinical Study Rate of Improvement following Volar Plate Open Reduction and Internal
More informationVisualize, stabilize, mobilize. Wristore * Distal Radius Fracture Fixator Abbreviated Surgical Technique
Visualize, stabilize, mobilize Wristore * Distal Radius Fracture Fixator Abbreviated Surgical Technique Wristore Distal Radius Fracture Fixator 1 Pin Placement Identify anatomy and make a direct (open)
More informationMadelung s Deformity 11/7/2016. Disclosures: Introduction:
Madelung s Deformity MICHAEL J GARCIA, MD FLORIDA ORHOPAEDIC INSTITUTE UNIVERSITY OF SOUTH FLORIDA NOVEMBER 5, 2016 Disclosures: I am a consultant for Arthrex, Inc I am on the Speaker s Bureau for Endo
More informationIncidence 643,000 per year United States 15% of all fractures, peak occurrence age 60 70, Classification - AO/OTA (Murray 2013)
Treatment of Distal Radial Fractures John M. Bednar, M.D. Associate Clinical Professor Orthopaedic Surgery, Thomas Jefferson University School of Medicine and The Philadelphia Hand Center Incidence 643,000
More informationAcu-Loc Wrist Plating System. Surgical Technique
Acu-Loc Wrist Plating System Surgical Technique Acumed is a global leader of innovative orthopaedic and medical solutions. We are dedicated to developing products, service methods, and approaches that
More informationJMSCR Vol 05 Issue 06 Page June 2017
www.jmscr.igmpublication.org Impact Factor 5.84 Index Copernicus Value: 83.27 ISSN (e)-2347-176x ISSN (p) 2455-0450 DOI: https://dx.doi.org/10.18535/jmscr/v5i6.32 Functional & Radiological Outcome of the
More informationInstrument and Implant for wrist fracture
Instrument and Implant for wrist fracture Jansri Janpanya Product specialist The Bangkok Unitrade Co,.ltd. Objectives Type of LCP for distal radius Fx. The new LCP design for distal radius Fx. Have knowledge
More informationFractures of distal end of Radius: A study on fracture reduction and stable fixation
IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 16, Issue 6 Ver. X (June. 2017), PP 27-31 www.iosrjournals.org Fractures of distal end of Radius: A study
More informationRadiographic Evaluation and Classification of Distal Radius Fractures
Radiographic Evaluation and Classification of Distal Radius Fractures Robert J Medoff, MD Introduction X-rays are essential to the treatment of distal radius fractures. When combined with the age and baseline
More informationCarpal Injuries. AO Advanced Principles of Fracture Management Middelfart, april 2016
Carpal Injuries AO Advanced Principles of Fracture Management Middelfart, 11.-14. april 2016 Overlæge Marianne Vestergaard Lind Traumesektionen Ortopædkirurgisk Klinik Rigshospitalet AOT Advanced Principles
More informationAcu-Loc 2 Wrist Plating System
Surgical Technique Acu-Loc 2 Wrist Plating System Acumed is a global leader of innovative orthopaedic and medical solutions. We are dedicated to developing products, service methods, and approaches that
More informationSean Walsh Orthopaedic Surgeon Dorset County Hospital
Sean Walsh Orthopaedic Surgeon Dorset County Hospital Shapes and orientation of articular surfaces Ligaments Oblique positioning of scaphoid Tendons surrounding the joints Other soft tissues Peripheral
More informationSurgical Technique. Wrist Plating System
Surgical Technique Wrist Plating System Acumed is a global leader of innovative orthopaedic and medical solutions. We are dedicated to developing products, service methods, and approaches that improve
More informationQUICK REFERENCE GUIDE. The Pennig Dynamic Wrist Fixator. Part A: Trans-articular application
10 The Pennig Dynamic Wrist Fixator Part A: Trans-articular application B1 B2 B3 III IV TRANS-ARTICULAR APPLICATION The fractures that can be treated with this technique include AO type B and C fractures,
More informationComparative Study between Bridging External Fixation vs Volar Plating (Ellis-T Plate) for Comminuted Fracture of the Distal End Radius
SK Venkatesh Gupta, Pradeep Mandapalli Clinical study 10.5005/jp-journals-10017-1051 Comparative Study between Bridging External Fixation vs Volar Plating (Ellis-T Plate) for Comminuted Fracture of the
More informationCase Report Bone Resection for Isolated Ulnar Head Fracture
Hindawi Case Reports in Orthopedics Volume 2017, Article ID 3519146, 4 pages https://doi.org/10.1155/2017/3519146 Case Report Bone Resection for Isolated Ulnar Head Fracture Hiromasa Akino, Shunpei Hama,
More informationCarpal rows injuries!
Carpal rows injuries! Michael Papaloïzos! Center for Hand Surgery and Therapy Geneva, Switzerland no conflict of interest to declare Fractures of carpal bones! The fractured scaphoid! Fracture-dislocations
More informationCOMPARATIVE STUDY OF FUNCTIONAL OUTCOME OF EXTERNAL AND INTERNAL FIXATION IN TREATMENT OF COMMINUTED DISTAL RADIUS FRACTURES
COMPARATIVE STUDY OF FUNCTIONAL OUTCOME OF EXTERNAL AND INTERNAL FIXATION IN TREATMENT OF COMMINUTED DISTAL RADIUS FRACTURES R. Sahaya Jose 1 1Assistant Professor, Department of Orthopaedics, Sree Mookambika
More informationUltrasonographic Assessment of the Flexor Pollicis Longus Tendon After Plate Fixation
Ultrasonographic Assessment of the Flexor Pollicis Longus Tendon After Plate Fixation Chieko Kadoma, MD; Masatoshi Takahara, MD, PhD; Masahiro Maruyama, MD; Hiroshi Satake, MD, PhD; Michiaki Takagi, MD,
More informationClinical Study Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed Angle Locking Plates
ISRN Orthopedics Volume 2013, Article ID 131757, 6 pages http://dx.doi.org/10.1155/2013/131757 Clinical Study Dorsally Comminuted Fractures of the Distal End of the Radius: Osteosynthesis with Volar Fixed
More informationComparisonofUlnar-ShorteningOsteotomyWitha NewTrimedDynamicCompressionSystemVersusthe SynthesDynamicCompressionSystem:ClinicalStudy
SCIENTIFICARTICLE ComparisonofUlnar-ShorteningOsteotomyWitha NewTrimedDynamicCompressionSystemVersusthe SynthesDynamicCompressionSystem:ClinicalStudy ShaiLuria,MD,AnthonyJ.Lauder,MD,ThomasE.Trumble,MD
More informationDistal Radius and Distal Ulna Plates System Self-Tapping Spherical Locking Screw Self-Tapping Conical Locking Screw Cortex Screw
DISTAL RADIUS AND ULNA LOCKING PLATE SYSTEM Surgical Technique Distal Radius and Distal Ulna Plates System Self-Tapping Spherical Locking Screw Self-Tapping Conical Locking Screw Cortex Screw Approved
More informationAesculap Orthopaedics Targon DR
Aesculap Orthopaedics Targon DR Intramedullary nail for the distal radius Stability from within Targon DR stability from within PD Dr. med. Georg Gradl, Dept. for Accident and Reconstructive Surgery at
More informationSCAPHOID FRACTURE. Relevant antomy
SCAPHOID FRACTURE Relevant antomy The proximal row consists of the scaphoid, the lunate, and the triquetrum. The proximal carpal row is regarded as an intercalated segment The keystone in the coordination
More informationWINSTA-R. Distal Radius System
Distal Radius System Table of Contents Introduction WINSTA-R System 2 Indication 2 Surgical Technique Palmar Access for Radius Plate 3 Dorsal Access for Radius Plate 3 Positioning of the Radius Plate
More informationOlecranon fracture. Lonnie Froberg, MD, Ph.D Rigshospitalet, Copenhagen University Hospital
Olecranon fracture Lonnie Froberg, MD, Ph.D Rigshospitalet, Copenhagen University Hospital 20% of forearm fracture 12 per 100.000 persons per year Low-energy fall Increased risk >50 years 90% AO 21.B1.1
More informationBASIC PRINCIPLES OF HAND TRAUMA: ARE CHILDREN DIFFERENT? SUSAN THOMPSON, MD, FRCSC
BASIC PRINCIPLES OF HAND TRAUMA: ARE CHILDREN DIFFERENT? SUSAN THOMPSON, MD, FRCSC EPIDEMIOLOGY HAND FRACTURES MAKE UP 2.3% OF ER VISITS INCIDENCE VARIES WITH AGE LOW IN TODDLERS INCREASES WITH AGE (20
More informationFragment-Specific Fixation of Distal Radius Fractures
Fragment-Specific Fixation of Distal Radius Fractures Robert J. Medoff 10 H P T E R DEFINITION Fragment-specific fixation is a treatment approach for complex articular fracture patterns characterized by
More informationFractures of the distal radius have occupied a storied history
Distal Radius Fractures: What Cannot Be Fixed With a Volar Plate? The Role of Fragment-Specific Fixation in Modern Fracture Treatment Jonathan Lam, MD, PhD,* and Scott W. Wolfe, MD, The advent of volar
More informationORIGINAL ARTICLE. possible. Accurate assessment of standard radiographs is essential for appropriate 3. management. And includes true posterior- 4
ORIGINAL ARTICLE Treatment of Colle's Fracture with Wrist Immobilization in Palmar flexed & Dorsiflexed Position Sohail Iqbal Shaikh, Abdul Basit, Javed Iqbal, Saba Sohail Shaikh, Imran Sohail Shaikh 26
More informationAcu-Loc 2 Wrist Plating System. Surgical Technique
Acu-Loc 2 Wrist Plating System Surgical Technique Acumed is a global leader of innovative orthopaedic and medical solutions. We are dedicated to developing products, service methods, and approaches that
More informationManagement of intra-articular fractures of distal end radius in adults
International Journal of Research in Orthopaedics Gawali SR et al. Int J Res Orthop. 2016 Dec;2(4):220-228 http://www.ijoro.org Original Research Article DOI: http://dx.doi.org/10.18203/issn.2455-4510.intjresorthop20163148
More informationBridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius
Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius A RANDOMISED, PROSPECTIVE TRIAL K. Egol, M. Walsh, N. Tejwani,
More informationAngle Stable Distal Radial Plate System WINSTA-R
Angle Stable Distal Radial Plate System WINSTA-R Priv.-Doz.Dr.med. Martin Walz Dr. med. Felix Menzinger Prof.Dr.med. Jürgen Rudigier www.marquardt-medizintechnik.de General The problem posed by metaphyseal
More informationCover Page. The handle holds various files of this Leiden University dissertation.
Cover Page The handle http://hdl.handle.net/1887/35777 holds various files of this Leiden University dissertation. Author: Wijffels, Mathieu Mathilde Eugene Title: The clinical and non-clinical aspects
More information2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology.
Technique Guide 2.4 mm Variable Angle LCP Volar Extra-Articular Distal Radius System. For fragment-specific fracture fixation with variable angle locking technology. Table of Contents Introduction 2.4
More informationORIGINAL ARTICLE TREATMENT DISTAL RADIUS FRACTURE WITH VOLAR BUTTRESS TECHNIQUE- A CLINICAL STUDY
TREATMENT DISTAL RADIUS FRACTURE WITH VOLAR BUTTRESS TECHNIQUE- A CLINICAL STUDY Neelanagowda V P Patil 1, Lingaraj 2, P S Kaladagi 3, Paramanda Hospeti 4, Nizamuddin 5. 1. Assistant professor, Department
More informationDistal radius fractures raises considerable interest and
Original Article Two peg spade plate for distal radius fractures A novel technique Sharad M Hardikar, Sreenivas Prakash, Madan S Hardikar, Rohit Kumar Abstract Background: The management of distal radius
More informationIC 30: Tips and Tricks for Management of Hand Fractures-Simple to Complex
IC 30: Tips and Tricks for Management of Hand Fractures-Simple to Complex Moderator(s): Randip R. Bindra, FRCS, MCh Orth Faculty: Andrea Atzei, MD, Donald H. Lalonde, MD, David S. Ruch, MD Session Handouts
More informationDistal radius fractures are
Clin Orthop Relat Res (2015) 473:3098 3104 / DOI 10.1007/s11999-015-4335-5 Clinical Orthopaedics and Related Research A Publication of The Association of Bone and Joint Surgeons Published online: 21 May
More informationMR IMAGING OF THE WRIST
MR IMAGING OF THE WRIST Wrist Instability Dissociative Pattern apparent on routine radiographs Non-dissociative Stress / positional radiographs Dynamic fluoroscopy during stress Arthrography MRI / MR arthrography
More informationDistal Radius Plate Instrument and Implant Set. Discontinued December 2017 DSUS/TRM/0916/1063(1)
Distal Radius Plate Instrument and Implant Set Surgical Technique Discontinued December 2017 DSUS/TRM/0916/1063(1) The Distal Radius Plates Indications For fixation of fractures and osteotomies, including
More informationIntra articular distal radius fractures and volar plate fixation: a prospective study
International Journal of Research in Orthopaedics Kundu AK et al. Int J Res Orthop. 2017 May;3(3):589-594 http://www.ijoro.org Original Research Article DOI: http://dx.doi.org/10.18203/issn.2455-4510.intjresorthop20171907
More informationFractures of the distal end of the radius should be
FRACTURES OF THE DISTAL END OF THE RADIUS TREATED BY INTERNAL FIXATION AND EARLY FUNCTION A PRELIMINARY REPORT OF 20 CASES DANIEL A. RIKLI, PIETRO REGAZZONI From the University Hospital, Basel, Switzerland
More informationOperative Indications
Distal Radius Fractures: Closed Treatment? Paul Tornetta III, MD Professor Boston Medical Center Boston Medical Center Operative Indications Age Initial films Dorsal comminution Intraarticular involvement
More informationA Patient s Guide to Adult Distal Radius (Wrist) Fractures
A Patient s Guide to Adult Distal Radius (Wrist) Fractures Suite 11-13/14/15 Mount Elizabeth Medical Center 3 Mount Elizabeth Singapore, 228510 Phone: (65) 6738 2628 Fax: (65) 6738 2629 1 DISCLAIMER: The
More informationDifference Between Angle You Can Bend Your Left Wrist Back vs Your Right Wrist Jenna Priest Science Department Altoona High School January 25, 2017
Difference Between Angle You Can Bend Your Left Wrist Back vs Your Right Wrist Jenna Priest Science Department Altoona High School January 25, 2017 Background 1- The wrist joint (also known as the radiocarpal
More informationSmall External Fixator Wrist Spanning Frame. For the treatment of wrist fractures.
Small External Fixator Wrist Spanning Frame. For the treatment of wrist fractures. Technique Guide Part of the Small External Fixation System Small External Fixator Wrist Spanning Frame When to use The
More informationSmall External Fixator Nonspanning Wrist Frame. For the treatment of wrist fractures.
Small External Fixator Nonspanning Wrist Frame. For the treatment of wrist fractures. Technique Guide Part of the Small External Fixation System Small External Fixator Nonspanning Wrist Frame When to use
More informationLCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius.
Technique Guide LCP Proximal Radius Plates 2.4. Plates for radial head rim and for radial head neck address individual fracture patterns of the proximal radius. Table of Contents Introduction LCP Proximal
More informationAcute Rupture of Flexor Tendons as a Complication of Distal Radius Fracture
60 pissn : 1226-2102, eissn : 2005-8918 Case Report J Korean Orthop Assoc 2015;50: 60-65 http://dx.doi.org/10.4055/jkoa.2015.50.1.60 www.jkoa.org Acute Rupture of Flexor Tendons as a Complication of Distal
More informationFunctional Outcome Of Intraarticular Distal Radius Fractures Managed By Volar Locking Compression Plate A Prospective Study
IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 17, Issue 3 Ver.11 March. (2018), PP 29-34 www.iosrjournals.org Functional Outcome Of Intraarticular
More informationLigaments of Elbow hinge: sagittal plane so need lateral and medial ligaments
Ligaments of Elbow hinge: sagittal plane so need lateral and medial ligaments Ulnar Collateral ligament on medial side; arising from medial epicondyle and stops excess valgus movement (lateral movement)
More informationHand Fracture System with Small Bone External Fixation System. Product Overview
Hand Fracture System with Small Bone External Fixation System Product Overview Acumed Hand Fracture System The Acumed Hand Fracture System is designed to provide both standard and fracture-specific fixation
More informationA prospective study of surgical management of distal radius fracture in adult with plate fixation
2017; 3(3): 236-240 ISSN: 2395-1958 IJOS 2017; 3(3): 236-240 2017 IJOS www.orthopaper.com Received: 14-05-2017 Accepted: 15-06-2017 Dr. Jagadeesh Babu Somesula MS (Orthopaedics), Assistant RVM Institute
More informationRadiographic Evaluation of Dorsal Screw Penetration After Volar Fixed-Angle Plating of the Distal Radius: A Cadaveric Study
HAND (2007) 2:144 150 DOI 10.1007/s11552-007-9038-2 Radiographic Evaluation of Dorsal Screw Penetration After Volar Fixed-Angle Plating of the Distal Radius: A Cadaveric Study Steven D. Maschke & Peter
More informationIntegra. Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE
Integra Spider and Mini Spider Limited Wrist Fusion System SURGICAL TECHNIQUE Table of contents Description... 02 Indications... 02 Contraindications... 02 Surgical Technique... 03 Spider Introduction-Four
More informationDistal Radius Plate 2.4/2.7 dorsal and volar
Distal Radius Plate 2.4/2.7 dorsal and volar Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Distal Radius Plate
More informationEvaluation of volar locking plate fixation for management of intraarticular fractures of distal end of radius
International Journal of Research in Orthopaedics Pathak RS et al. Int J Res Orthop. 2018 Mar;4(2):193-197 http://www.ijoro.org Original Research Article DOI: http://dx.doi.org/10.18203/issn.2455-4510.intjresorthop20180400
More informationepak Single-Use Delivery System
epak Single-Use Delivery System featuring DVR Crosslock Volar Rim Surgical Technique Peel the Seal and You re Ready to Go! One Surgeon. One Patient. Over 1 million times per year, Biomet helps one surgeon
More informationAcute Wrist Injuries OUCH!
Acute Wrist Injuries OUCH! Case the athlete FOOSH from sporting event 2 days ago C/O wrist swelling, pain, worse with movement Hmmm Wrist pain Exam of the wrist - basics Appearance Swelling, bruising,
More informationThe Utility of the Fluoroscopic Skyline View During Volar Locking Plate Fixation of Distal Radius Fractures
Scientific Article 245 The Utility of the Fluoroscopic Skyline View During Volar Locking Plate Fixation of Distal Radius Fractures Lucile Vaiss, MD 1 Satoshi Ichihara, MD, PhD 1,2 Sarah Hendriks, MD 1
More informationVolar Distal Radius Plating System Surgical Technique
Volar Distal Radius Plating System Surgical Technique Acu-Loc 2 Volar Distal Radius Plating System Acumed is a global leader of innovative orthopaedic and medical solutions. We are dedicated to developing
More informationArhtroscopy of the wrist joint: Setup, instrumentation, anatomy & indications
Arhtroscopy of the wrist joint: Setup, instrumentation, anatomy & indications Andreas Panagopoulos, MD, PhD Upper Limb and Sports Medicine Surgeon Assistant Professor in Orthopaedics Patras University
More informationPROXIMAL AVULSION of RADIOCARPAL CAPSULE Parc Lesion: a new entity
PROXIMAL AVULSION of RADIOCARPAL CAPSULE Parc Lesion: a new entity Ch. Mathoulin PARC LESION Parc lesion is a large capsular tear of the dorsal wrist capsule, from TFCC to DCSS, often neglected in wrist
More information