1 -CH Laboratory Safety Manual Laboratory Ventilation Policy PURPOSE The University of North Carolina at Chapel Hill (University) is committed to providing students, faculty and staff with engineering controls that minimize their exposure to hazardous materials. This policy addresses the installation, removal, change, and monitoring of ducted and non-ducted equipment used to control exposure to chemicals, toxins, radionuclides, and biohazard agents at the University. DEFINITION Types of Protection Common hoods and cabinets used at -CH that provide worker protection by enclosing the hazardous operation include the chemical fume hood and the biological safety cabinet (BSC). The Clean Bench does not offer worker protection. For more information about safe use of chemical hoods, refer to the Laboratory Safety Manual, Chapter 17. For more information about the safe use of biosafety cabinets, refer to the Biological Safety Manual, Chapter 9. Snorkel Units (Protection from vapors and gases) Chemical Fume Hoods (Protection From Vapors And Gases) Biological Safety Cabinets (Protection From Particulates and minute/small amounts of gases)) Clean Benches (No Worker Protection) Ductless Fume Hoods (Protection From Vapors And Gases) Worker Product Environment Selection and Purchase University Materials & Disbursement Services requires the approval of the Directors of Facilities Services and Environment, Health and Safety (EHS) (or their designees) for the 1
2 -CH Laboratory Safety Manual purchase of a ducted biological safety cabinet, a snorkel unit or a ducted or ductless chemical fume hood. Examples of Director designees are Engineering Supervisors, Biological Safety Officers and Chemical Hygiene Officers. Investigators who wish to bring Chemical Fume Hoods or Biological Safety Cabinets with them from a previous location must seek approval from EHS prior to shipment. All newly installed Chemical Fume Hoods and ducted Biological Safety Cabinets shall be equipped with a static pressure gauge and alarm to continuously monitor hood airflow. Gauges shall be selected to operate at 50% of full range. Alarms shall be calibrated to alarm at +/- 20% of designed airflow. The purchase and installation of an auxiliary air hood is not permitted. Clean Benches may not be approved for use with hazardous materials. The purchase and installation of ducted Biological Safety Cabinets must follow the Flammable Gases Policy. The purchase and installation of a ductless fume hood must be approved by the EHS Director (or designee) and filter-changing/testing conducted at the expense of the PI or department and documented on the Laboratory Safety Plan (Schedule B). Ductless fume hoods are designed to remove hazardous fumes and vapors from the work area by passing the exhaust air through a filter and/or adsorbent, such as activated charcoal. Because of the potential for unregulated use and personnel exposure through a "breakthrough" and desorption of vapors from the hood s filtering system, EHS recommends using ducted hoods wherever possible. Ductless hoods should be used only when ducted hoods cannot be reasonably utilized or accommodated MODIFICATIONS Responsibilities: Users of ducted and ductless chemical fume hoods and biological safety cabinets are responsible for maintaining the unit in its original condition and minimizing storage of materials inside the hood/cabinet. EHS will assess hoods during safety audits for materials that may potentially restrict airflow. Students, faculty, staff, and Facilities Services personnel must not modify hoods or biosafety cabinets by drilling, cutting, adding or removing the hardware that was originally provided with the hoods. Such modifications are likely to degrade containment/performance of the unit and result in leakage of contaminants. An exception is installing a standard latticework of monkey bars at the rear of a chemical fume hood. Installers must follow the chemical fume hood manufacturer s recommendations when installing these support bars. When in doubt, 2
3 -CH Laboratory Safety Manual contact EHS. Any other proposed hood modifications must be reviewed and approved by EHS in advance and then tested following completion. ALARMS and REPAIR Responsibilities: Users of chemical fume hoods are responsible for contacting Facilities Services at if the hoods go into alarm or the gauge indicates poor hood performance. Users of biological safety cabinets are responsible for contacting their third-party vendor (or EHS at , if unknown) if the alarm sounds or the gauge indicates poor cabinet performance. Users must follow shut down procedures and place a sign on the chemical fume hood or biological safety cabinet to notify others: Out of Service/Do Not Use. Facilities Services will coordinate all responses to requests for ventilation system repair and contact EHS for a Safety Clearance Form as indicated in the worker s Hazards Management Plan. All system outages (planned or unplanned) require that laboratory notification, posting, and appropriate shutdown procedures be followed. Maintenance personnel shall follow all applicable OSHA standards as indicated in their Hazards Management Plan (e.g., hazard communication, lockout-tagout, personal protective equipment). Directors or Department Chairs of the affected laboratories and EHS must be notified of all ventilation outages that will exceed four hours in duration. PREVENTIVE MAINTENANCE Responsibility: Facilities Services. As with all mechanical systems, inspections and regular preventive maintenance are critical to ensure that laboratory exhaust systems operate without unscheduled interruptions in service. Facilities Services personnel maintain records of all inspections and corrective actions for each laboratory building. Depending on the item, inspections are done quarterly, semiannually or annually. Laboratory occupants must receive advanced notification of planned fan stoppage and label the hood or ducted cabinet Out of Service/Do Not Use during the procedure. 3
4 -CH Laboratory Safety Manual AUTHORIZATION Authorization for removal, change, or installation of laboratory ventilation: A ducted or ductless chemical fume hood, snorkel unit or ducted biological safety cabinet cannot be installed at the University without the approval of the Directors of Facilities Services and Environment, Health and Safety, or their designees. Authorization for Startup. To prevent the exposure of students, faculty and staff to volatile radionuclides, reproductive hazards, carcinogens, toxins, and biological hazards, EHS will not permit hazardous materials in a new laboratory until its ducted or ductless chemical fume hoods, ducted biological safety cabinets, and general ventilation system are performing according to the project s design and manufacture s specifications. The EHS Director, or designee, will make this decision based on the available information, including tests by the contractor, Facilities Services staff and EHS. All Chemical Fume Hoods: o Must pass the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 110 as-installed test, including a Sulfur Hexafluoride (SF 6 ) challenge. Contact EHS for recommended testers. Testing shall be done at the user s expense. See Addendum 1 for additional testing requirements. Until the EHS Director or designee authorizes the startup of a new ducted or ductless chemical fume hood: In an occupied laboratory, the hood will be posted with an Out of Service/Do Not Use sign. EHS will not authorize the new laboratory for radioactive material use. EHS will not move chemicals into the new laboratory. EHS will instruct laboratory staff to not move any hazardous materials, including BSL-2 materials into the new laboratory. Third party commissioning is required for Variable Air Volume (VAV) laboratory hood systems. REMOVAL Responsibilities: The Building Manager, Department Administrator, and/or Project Manager will coordinate all requests for chemical fume hood or ducted biological safety cabinet removal and will notify EHS for Safety Clearance procedures. Design Services of Facilities Services will oversee the airflow assessment and balance. Facilities Services Movers will not move a chemical fume hood or biological safety cabinet without an EHS Safety Clearance Form. 4
5 -CH Laboratory Safety Manual Because ducted chemical fume hoods, snorkel units and ducted biological safety cabinets may supply the majority of a room s exhaust, removal of these units may require careful calculation to maintain safe and comfortable air in the space afterwards. Once the airflow assessment is signed off by Design Services of Facilities Services, EHS is called in to conduct a safety clearance for the physical removal of the hood. Biological safety cabinets must also obtain microbiological decontamination that meets or exceeds the NSF-49 standard prior to being moved. A chemical fume hood or biological safety cabinet is never to be moved without an EHS Safety Clearance Form. INSTALLATION/REPLACEMENT Responsibility: Users or their representatives, Facilities Services, EHS. The design of ducted chemical fume hood, snorkel units and ducted biological safety cabinet and overall laboratory ventilation systems must consider their physical environment and integration into the building s supply and exhaust systems. System components include the hood or ducted cabinet, airflow alarm and gauge, supply and exhaust air requirements, general room ventilation, and Variable Air Volume (VAV) controls. After installation or replacement and prior to use, the safety of the chemical fume hood or biological safety cabinet must be validated. All Chemical Fume Hoods: o Must pass the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) 110 as-installed test, including a Sulfur Hexafluoride (SF 6 ) challenge. Contact EHS for recommended testers. Testing shall be included in the cost of the project. See Addendum 1 for additional testing requirements. o In laboratories designed to require that corridor doors be normally closed, require smoke puff tests at the bottom of the closed doors. (To pass, no smoke can escape into the corridor.) All Biological Safety Cabinets: o Must pass the National Safety Foundation (NSF) standard 49 certification for Class II (Laminar Flow) Biosafety Cabinetry. Contact EHS for recommended certifiers. o In laboratories designed to require that corridor doors be normally closed, require smoke puff tests at the bottom of the closed doors. (To pass, no smoke can escape into the corridor.) Project budgets over $300K involving laboratories (both major and download) typically include major revisions to, or replacement of, existing HVAC systems, ductwork, hoods, cabinets, and control systems. For these projects, specifications for the design, purchase, installation, testing 5
6 -CH Laboratory Safety Manual and balancing of chemical fume hoods, ducted biological safety cabinets and laboratory ventilation systems are detailed in the University Design Guidelines and may require approval from State Construction. As described in the Guidelines, a rigorous, detailed review process for the entire ventilation system must be undertaken early in the project. Design and construction must follow coordinated, sequential steps to assure that all components of the system are considered and will perform properly. Project budgets under $300K involving laboratory ventilation or the installation of new or replacement chemical fume hoods or ducted biological safety cabinets are managed through Design Services of Facilities Services. Facilities Services will determine whether a building can adequately support a proposed chemical fume hood or ducted biological safety cabinet. An engineering assessment of existing mechanical and electrical systems must be performed before units can be added, removed, or replaced. As much as practicable, specifications should rely on the University Design Guidelines, may require approval from State Construction, and design drawings and specifications shall be sealed by a Professional Engineer. ANNUAL HOOD AND SYSTEM TESTING EHS manages the University Biosafety Cabinet and Chemical Fume Hood Inspection and Airflow Measurement Program that ensures testing standards are met and maintains databases of all fumehood airflow testing and biosafety cabinet certifications at -CH. Chemical Fume Hoods Responsibility: EHS. Testing shall occur with HVAC systems operating at 100%. Qualified and trained personnel shall conduct testing. At a minimum, the following test procedures will be followed: Visual inspection for hood damage, modifications or congestion. Face velocity measurements at the designated working sash position. (To pass, the average velocity must be within plus 20% or minus 10% of the design rating at the standard operating sash opening. This is typically fpm. For most chemical fume hoods at the University, standard operating sash opening is 18 inches sash height, or two panes open on a combination sash hood.) Chemical fume hood alarm test. 6
7 -CH Laboratory Safety Manual Tested chemical fume hoods will have EHS labels affixed stating the following: test date; initials of inspector, and face velocity readings at the standard operating sash opening as indicated on the test label. For chemical fume hoods found to be outside of the designated range at the standard operating sash opening, Facilities Services will be contacted for airflow adjustments (this does not apply to low flow chemical fume hoods). EHS will post hoods: Out of Service/Do Not Use. Hoods that are posted Out of Service/Do Not Use may need to be emptied and cleaned as determined by the EHS Safety Clearance procedure to prevent chemical exposures for lab occupants and personnel who will repair the hood system. Radiation Chemical Fume Hoods: If a radioactive materials posted hood is above 90 fpm and below 100 fpm, a request for airflow adjustment should be submitted to Facilities Service as soon as practicable. The hood can be continued to be used if below 100 fpm as long as it is posted as Air flow adjustment has been requested. If below 90 fpm the hood should not be used for radioactive materials until adjustments are made. EHS will post hoods: Out of Service/Do Not Use. After repairs, EHS or Facilities Services, as appropriate, will perform follow-up testing. Low Flow Chemical Fumehoods Low flow chemical fumehoods are manufactured as low flow hoods. It is designed to be an energy savings fumehood. A low flow hood is one that has had the exhaust volume reduced by operating through a smaller sash opening. This type of hood does not require the containment be the same with the sash full open for setup as it is for usage. Energy savings can parallel that of low velocity hoods, but proper sash position for usage or setup must be managed. These fume hoods will be tested by EHS based on the manufacturers criteria. Biological Safety Cabinets Responsibility: Users. EHS recommends annual certification for all biosafety cabinets at biosafety level 1 (BSL-1) and BSL-2; however, if the BSL-2 cabinet is used for concentrations of risk group 2 agents, annual certification is required. This includes ducted and non-ducted biosafety cabinets. All biosafety cabinets at BSL-3 are certified annually. Contact EHS at to arrange for certification. 7
8 Snorkels -CH Laboratory Safety Manual Upon request EHS can check the airflow on an existing snorkel. Contact EHS at Key References: ANSI/AIHA Z9.5 (most current) ASHRAE (or most current) NSF/ANSI-49 (most current) EHS Laboratory Design Guidelines (most current) Laboratory Safety Manual (most current) Biological Safety Manual (most current) 8
9 -CH Laboratory Safety Manual -Chapel Hill Dept. of Environment, Health and Safety Chemical Fume Hood Certification Performance Requirements Addendum 1 1. Follow ASHRAE flow visualization test with low and high volume smoke at designed opening, 18. Hood should not be loaded. a. Pass/Fail Criteria RATING DESCRIPTION FAIL LOW PASS (Poor) PASS (Fair) HIGH PASS (Good) Smoke was visually observed escaping from the hood Reverse flow of smoke is evident near opening Lazy flow into hood along openings Slow capture and clearance Observed potential for escape Some Reverse flow in hood not necessarily at opening Limited turbulent vortex flow inside hood Smoke is captured and clears readily No visible escape Good capture and quick clearance Limited vortex flow inside hood No reverse flow regions No visible escape 2. Face Velocity should be 100fpm, +20% or -10% at designed opening (per ANSI Z9.5). a. No single point in the face velocity testing may be +/- 20% of the average, at designed opening. b. Test face velocity at 50% and 25% of designed opening. At 50% opening, face velocity should be fpm. At 25% of design opening, face velocity should be fpm. 3. Perform ASHRAE tracer gas test at 4Lpm. Results must be less than 0.05ppm. a. Vertical hoods should be tested in the right, left, and center positions at designed opening. b. For horizontal sashes, test with the maximum opening in the left, right, and center positions. 9
10 -CH Laboratory Safety Manual c. All tracer gas testing should be performed with the hood loaded. 4. Perform walk-by test with tracer gas with the mannequin in the center position. Execute three rapid walk-bys, 12 inches behind the mannequin, at 30 second intervals. Tracer gas concentration shall not exceed 0.1ppm and should return to specified containment within 15 seconds. 5. All testing should be done using the specific diversity factor for at least the section of the floor being tested, if not the entire building, to ensure the total of the fume hood exhaust system is being challenged, as applicable. 6. Test Fume Hood Alarms a. Alarm should activate when hood sash is fully open. b. Alarm reading should match tested face velocity. 10
11 -CH Laboratory Safety Manual Contacts Mike Long Cathy Brennan Assicate Chemical Hygiene Officer Chemical Safety Manager/CHO Chapel Hill Chapel Hill 1120 Estes Drive Extension 1120 Estes Drive Extension Campus Box 1650 Campus Box 1650 Chapel Hill, NC Chapel Hill, NC Office: Office: Mary Beth Koza, MBA Director Dept. of Environment, Health and Safety Chapel Hill 1120 Estes Drive Extension Campus Box 1650 Chapel Hill, NC Office: Document History Effective Date: April 10, 2014 (date approved by University Safety and Security Committee, chaired by Vice Chancellor for Finance and Administration) 11
THE UNIVERSITY OF ALABAMA FUME HOOD MANAGEMENT PLAN
THE UNIVERSITY OF ALABAMA FUME HOOD MANAGEMENT PLAN ENVIRONMENTAL HEALTH AND SAFETY 410 CAMPUS DRIVE EAST BOX 870178 TUSCALOOSA, ALABAMA 35487 (205)348-5905 Table of Contents 1. Scope...3 2. Purpose.3
More informationEnvironmental Health & Safety Policy Manual
Environmental Health & Safety Policy Manual Issue Date: 5/31/2017 Policy # EHS-400.17 Isoflurane Use and Exposure Control Procedures 1.0 PURPOSE: LSUHSC is committed to keeping all exposures to hazardous
More informationPersonal Protective Equipment:
have, at a minimum a legible label to identify the contents even if it is water or benign material. Hazardous chemical containers must have the following: - Original manufacturer label with the date received
More information2016 EHS Annual review
2016 EHS Annual review May 2016 University of Michigan Note from the EHS Executive Director Inside this issue: Research Safety 1-4 Shop Safety 4 Radiation Safety 5 Biological Safety 6 Food Safety 6 Ergonomics
More informationSTANDARD OPERATING PROCEDURES (SOP) FOR CARCINOGENS
STANDARD OPERATING PROCEDURES (SOP) FOR CARCINOGENS INTRODUCTION: Standard operating procedures (SOP) are intended to provide you with general guidance on how to safely work with a specific class of chemical
More informationSection 7 ALARA Program
Page 7-1 Section 7 ALARA Program Contents A. ALARA Principle... 7-2 1. Biological Basis... 7-2 2. Applied Practices... 7-3 3. Operational Dose Limits... 7-3 4. Collective Dose... 7-3 B. Radiation Safety
More informationIn this issue of the Environmental Health and Safety (EHS) Listserv, January 16, 2014:
In this issue of the Environmental Health and Safety (EHS) Listserv, January 16, 2014: 1. Plucking Dollars from the Sky? 2. Correct Laboratory Hood/Cabinet? Correct Use? 3. Elements of Creating Safety
More informationLaboratory Orientation and Safety
Laboratory Orientation and Safety Laboratory Safety Prevention of physical injuries and laboratory acquired infections with zoonotic disease agents Laboratory safety is every employee s responsibility!
More informationHearing Conservation Program. Santa Clara University 500 El Camino Real Santa Clara, CA 95053
Hearing Conservation Program Santa Clara University 500 El Camino Real Santa Clara, CA 95053 December 10, 2013 Program Approval Signature on file in the EHS Office 5/19/10 Signature Date Joe Sugg Assistant
More informationAppendix A: Record Retention Guide for Environmental Health and Safety Records
s for Safety, Health and Protection Document - AD-015 3 Appendix A: Guide for Health and Safety s Area Type Required by Access to s Aerial Lifts and bucket Trucks Air Emissions Inventory Air - Any hazardous
More informationOKLAHOMA STATE UNIVERSITY X-RAY MACHINE PROGRAM AND PI HANDBOOK For easy navigation, please use Adobe s bookmark feature.
OKLAHOMA STATE UNIVERSITY X-RAY MACHINE PROGRAM AND PI HANDBOOK For easy navigation, please use Adobe s bookmark feature. Table of Contents Overview... 2 Section 1: X-ray Program Oversight... 2 1.a: Institutional
More informationWherever air quality is critical, we take care of every breath you take. Enabling Wellbeing
Wherever air quality is critical, we take care of every breath you take. Halton Vita Values Putting people first Passion for better solutions Solving each challenge together Halton Vita solutions are made
More informationNo. GA Page 1 of 7 Effective Date: 03/04/ CFR (c), ANSI/ISEA Z TITLE: Chancellor Date: 03/04/16
TEXAS STATE TECHNICAL COLLEGE STATEWIDE OPERATING STANDARD No. GA 1.6.9 Page 1 of 7 Effective Date: 03/04/16 DIVISION: SUBJECT: AUTHORITY: General Administration Eyewash and Shower Stations 29 CFR 1910.151(c),
More informationIARC - International Agency for Research on Cancer - Classifies carcinogens in the following manner:
ESHD 5008, Section 8, Chapter 2 Carcinogens, Mutagens, and Teratogens Rev. 3 Page 1 of 10 Approved 10/21/98 CHAPTER 2 CARCINOGENS, MUTAGENS, AND TERATOGENS 2.1 INTRODUCTION The purpose of this chapter
More informationTHE BAKER COMPANY 161 Gatehouse Rd., Sanford, Maine USA Creating Immaculate Atmospheres
Microbiological Testing Report BioProtect IV with Becton Dickenson FACS Aria III April 26, 2011 Customer Becton Dickenson Biosciences Microbiological Testing Robert Thibeault Data Reference Document number:
More informationREMEMBER, SAFETY FIRST!
Lab Chatter Table of contents: Page 1.Safety Spotlight: Proper Lab Attire Page 2.Minors in UNE Laboratories Page 3.UNE minors on campus Waiver Release Form Page 4.EHS enhances outreach to students for
More informationHazard Communication Program. Santa Clara University (SCU) 500 El Camino Real Santa Clara, CA 95053
Hazard Communication Program Santa Clara University (SCU) 500 El Camino Real Santa Clara, CA 95053 February 2018 Program Review Record Revision 1 - January 2011 Name Title Department Jeff Charles Director
More informationEnergy-Efficient Biological Safety Cabinet Reduces Energy Costs While Ensuring Safety
Energy-Efficient Biological Safety Cabinet Reduces Energy Costs While Ensuring Safety Robert Lloyd David C. Eagleson Dennis Eagleson ABSTRACT As the primary containment devices within laboratories, biological
More informationHearing Conservation Program
Hearing Conservation Program June 2018 Hearing Conservation Program Table of Contents I. Purpose II. III. Responsibilities Program Directives A. Noise Exposure Monitoring B. Audiometric Testing C. Control
More informationAsbestos Awareness Training Environmental Health and Safety. Home Page
Asbestos Awareness Training Environmental Health and Safety Home Page 1 Table of Contents Introduction Terms and Definitions Common Asbestos Acronyms What is Asbestos? Why is Asbestos a Hazard? When is
More informationSpill and Release Response Procedures
Page #: 1 of 6 Last Reviewed/Update Date: 03/01/16 Spill and Release Response Procedures 1. Purpose / Background This document describes the procedures used by the Massachusetts Institute of Technology
More informationHealth & Safety, Edinburgh Napier University
Health & Safety, Edinburgh Napier University Version number 2.0 Version date October 2018 Review Date 1 : 1 or earlier if change in legislation or on risk assessment Approval/Authorised Signature Distribution
More informationHEARING CONSERVATION PROGRAM
HEARING CONSERVATION PROGRAM Prepared By: ENVIRONMENTAL HEALTH AND SAFETY OFFICE 0 Revision Table of Contents Introduction..3 Hearing Conservation Responsibilities.....4 Identification of Noise Exposure...5
More informationEnvironmental Health and Safety RESPIRATORY PROTECTION PROGRAM
Environmental Health and Safety RESPIRATORY PROTECTION PROGRAM Revised February 2012 TABLE OF CONTENTS 1 INTRODUCTION... 1 1.1 Regulatory Authority... 1 1.2 Application... 1 1.3 Glossary... 1 1.4 Overview...
More informationHearing Conservation Program
The University of Memphis Hearing Conservation Program December 2016 Table of Contents University of Memphis Hearing Conservation Program Contents Purpose... 1 Scope and Application... 1 Responsibilities...
More informationSUBJECT: Effective Date: Policy Number: Controlled Substance and Prescription Drugs 11/30/
Division of Research SUBJECT: Effective Date: Controlled Substance and Prescription Drugs 11/30/2018 Supersedes: Page Of 12/04/2015 04/25/2007 1 6 Responsible Authorities: Vice President, Research Institutional
More informationHEARING CONSERVATION PROGRAM
SUNY OSWEGO FACILITIES SERVICES ENVIRONMENTAL HEALTH & SAFETY HEARING CONSERVATION PROGRAM Program Number EHS-HCP-2014 Original Effective Date 2007 Revision Number-Date 12/01/2014 1.0 Purpose 2.0 Scope
More informationTAMPA ELECTRIC COMPANY ENERGY SUPPLY HEARING CONSERVATION PROGRAM
TABLE OF CONTENTS TITLE PAGE # PURPOSE / INTRODUCTION / SCOPE 1, 2 ROLES AND RESPONSIBILITIES 2 EMPLOYEE TRAINING 3 ENGINEERING CONTROLS 4 NOISE EXPOSURE EVALUATION 4 SIGNAGE / POSTING 4-5 AUDIOMETRIC
More informationSUBJECT: Management of Human Body Fluids/Waste (Bloodborne Pathogens)
Page 1 of 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 PURPOSE To establish uniform procedures for the safe management of human body fluids
More informationTECHNICAL BULLETIN GENERAL INFORMATION
TECHNICAL BULLETIN GENERAL INFORMATION NU-612 SMALL ANIMAL CAGE CHANGING STATION PERFORMANCE EVALUATION 2100 Fernbrook Lane Plymouth, MN 55447-4722 U.S.A. Phone: 763.553.1270 Fax: 763.553.0459 Toll Free:
More informationEnvironmental Health and Safety. Hearing Conservation Program
Environmental Health and Safety Hearing Conservation Program Date of Issuance: 07/23/2018 Revision Number: Initial Revision Date: Prepared by: EH&S 1. Purpose Carnegie Mellon University (CMU) has developed
More informationCommitted to Environment, Health and Safety
Committed to Environment, Health and Safety Environment, Health and Safety Management System and Policy of GCP Applied Technologies Inc. SEPTEMBER 1, 2017 The GCP Environment, Health, and Safety Management
More informationSan Diego Community College OSHA Standards
San Diego Community College OSHA Standards Hearing Conservation Program REV 5 11/19/2015 Original: 10/29/15 Rev 2: 10/29/15 Rev 3: 11/06/15 Rev 4: 11/10/15 Rev 5: 11/19/15 Table of Contents PURPOSE...
More informationSAFETY SHOWERS AND EYEWASHES 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS
224500 SAFETY SHOWERS AND EYEWASHES PART 1 GENERAL 1.01 RELATED CORNELL DESIGN AND CONSTRUCTION STANDARDS A. Section 013010 Accessibility for People with Disabilities B. Section 115000 Laboratory Equipment
More informationLEAD SAFETY PROGRAM. Purpose. Scope. Responsibilities. Southern Heat Exchanger Services Safety Program
Page: Page 1 of 5 Purpose The purpose of this procedure is to identify the controls and actions necessary to prevent adverse health effects to employees from occupational exposure to lead, and to ensure
More informationRecords Retention for Safety, Health and Environmental Protection
s for Safety, Health and Protection University of Tennessee Safety Procedure AD-015 Document Contact: EHS Date effective: February 1, 2010 Revision Date: December 15, 2014 Purpose The purpose of this procedure
More informationHearing Conservation Program April 27, 2018
Hearing Conservation Program April 27, 2018 1.0 INTRODUCTION 1.1 Purpose The purpose of the Indiana University Hearing Conservation Program is to prevent occupational noise exposures which could lead to
More informationCarcinogens STANDARD OPERATING PROCEDURE (SOP) Click here to enter a date. REQUIRED - Insert Preparer's Name CLSC SOP Task Force
Carcinogens STANDARD OPERATING PROCEDURE (SOP) Type of SOP: Process Hazardous Chemical Hazardous Class All personnel who are subject to these SOP requirements must review a completed SOP and sign the associated
More informationBiosafety Level 2 Standard Practices and Containment Office of Research Safety Affairs
Biosafety Level 2 Standard Practices and Containment Office of Research Safety Affairs Purpose and Objectives Purpose To promote the safe conduct of research with biohazardous materials known to present
More informationAbu Dhabi EHSMS Regulatory Framework (AD EHSMS RF)
NOWLEDGEMENTS With gratitude Abu Dhabi EHS Center acknowledges the great support provided by the Executive Council in facilitating the issuance of Abu Dhabi Emirate Environment, Health and Safety Management
More informationLean and Environment Training Modules Version 1.0 January 2006
Lean and Environment Training Modules Version 1.0 January 2006 Next Page Lean and Environment Training Module 5 6S (5S+Safety) Previous Page Next Page Purpose of This Module» Learn why Environment, Health,
More informationHearing Conservation Program
1500 - Hearing Conservation Program DOCUMENT HISTORY Version Date Comments 1.0 January, 2016 Initial Hearing Conservation Program 2.0 July, 2017 Annual Review This document will be reviewed routinely and
More informationUCSD HEARING CONSERVATION PROGRAM Environment, Health & Safety (EH&S) and Center for Occupational & Environmental Medicine (COEM) 2017
UCSD HEARING CONSERVATION PROGRAM Environment, Health & Safety (EH&S) and Center for Occupational & Environmental Medicine (COEM) 2017 Table of Contents Purpose Applicable Regulations and Standards Responsibilities
More informationReport on Exposure to Animal Allergens in the Biomedical Research Facility March 21, 2003
Report on Exposure to Animal Allergens in the Biomedical Research Facility March 21, 2003 Background On March 6, 2003, Environmental Health and Safety (EH&S) was advised that an incident had occurred in
More informationEyewash and Safety Showers HM 20 Page 1
Policy Subject: Safety Showers and Eyewash Effective: 12/01/09 Stations Affected Area/Department: University of Tennessee Reviewed/Revised: 12/15/08 Policy It shall be the policy of the University of Tennessee
More informationBiosafety Level 3 (BL3)
Biosafety Level 3 (BL3) NIH Guidelines for Research Involving Recombinant or Synthetic Nucleic Acid Molecules (Appendix G-II-C) - April 2016 Biosafety Level 3 (BL3) Biosafety Level 3 is applicable to clinical,
More informationOccupational Health & Safety in the Animal Care and Use Program
Occupational Health & Safety in the Animal Care and Use Program May 19, 2016 Table of Contents I. Purpose and Application... 5 II. Responsibilities... 5 III. Hazard Recognition... 6 IV. Control Measures...
More informationLab-Specific Standard Operating Procedure (LSOP)- Picric Acid (2,4,6-Trinitrophenol) and Solutions Containing Picric Acid
Office of the Vice President for Research Environmental Health and Safety Policies, Programs and Procedures Lab-Specific Standard Operating Procedure (LSOP)- Picric Acid (2,4,6-Trinitrophenol) and Solutions
More informationBiosafety & Biosecurity in the Laboratory. Based on the OIE Terrestrial Manual for Diagnostic Tests and Vaccines
Biosafety & Biosecurity in the Laboratory Based on the OIE Terrestrial Manual for Diagnostic Tests and Vaccines Keeping people and animals safe Keeping samples safe Definitions Biosafety: The measures
More informationHEARING CONSERVATION PURPOSE
HEARING CONSERVATION PURPOSE The purpose of a Hearing Conservation Policy (HCP) is to prevent occupational noise exposures which could lead to noise-induced hearing loss and to comply with existing Occupational
More informationHearing Conservation Program
Hearing Conservation Program Subject Matter Expert Brandi E. Kissel bek66@cornell.edu 607-882-5273 Page 1 of 9 Contents 1.0 INTRODUCTION... 2 2.0 OBJECTIVES AND METRICS... 2 3.0 SCOPE... 2 4.0 ROLES AND
More informationHearing Conservation Program
1. Introduction The University of Denver (HCP) is written in accordance with the Occupational Safety and Health Administration (OSHA) General Industry Standard Occupational Exposure to Noise CFR 1910.95
More informationAn Overview of The CA Whole House Home Energy Rating System (HERS II) Presented by CalCERTS, Inc.
An Overview of The CA Whole House Home Energy Rating System (HERS II) Presented by CalCERTS, Inc. Background In 1992 the first Home Energy Rating System (HERS) was established in California, called California
More informationMONITORING OF OCCUPATIONAL EXPOSURE AT NUCLEAR FACILITIES
GUIDE YVL 7.10 / 29 JANUARY 2002 MONITORING OF OCCUPATIONAL EXPOSURE AT NUCLEAR FACILITIES 1 GENERAL 3 2 PROVISIONS OF THE RADIATION ACT AND DECREE 3 3 MONITORING OF RADIATION EXPOSURE 4 3.1 General requirements
More informationOWNER S MANUAL and INSTALLATION INSTRUCTIONS
NP-L5003 Ab Crunch OWNER S MANUAL and INSTALLATION INSTRUCTIONS Leverage Ab Crunch Owner s Manual Copyright 2017. Core Health and Fitness, LLC. All rights reserved, including those to reproduce this book
More informationEffective Airflow Visualization Studies. Gordon Farquharson, July 2017
Effective Airflow Visualization Studies Gordon Farquharson, July 2017 Slide 1 PharmOut 2017 Agenda Regulatory imperative Role of CFD Air velocity measurements Airflow visualisation to prove effectiveness
More informationTitle: Supplementary guidelines on handling of
Revised 1 st July 2006 Page 1 of 7 Supplementary Guideline on Handling of Clinical Specimens in the Laboratory (Revised July 2006) The following guidelines are supplementary to existing standard laboratory
More information866-362-2691 www.westernfirstaid.com LAWS, CODES AND... Occupational Safety and Health Administration OSHA 29 CFR 1910.151, Subpart k, Section c Where the eyes or body of any person may be exposed to injurious
More informationProgram Title Indoor Air Quality. Classification General Safety. Program No INTRODUCTION
ENVIRONMENTAL HEALTH AND SAFETY EHS PROGRAM MANUAL Program Title 1.0 INTRODUCTION 7.7 General Safety As part of the Weill Cornell Medical College (WCMC) Environmental Health and Safety (EHS) Program Manual,
More informationUNIVERSITY POLICY. Revised: Contact:
UNIVERSITY POLICY Policy Name: Policy for Controlled Substances Section #: 90.2.3 Section Title: Compliance Approval Authority: Responsible Executive: Responsible Office: Formerly Book: President Adopted:
More information40 CFR PART DENTAL OFFICE POINT SOURCE CATEGORY
40 CFR PART 441 - DENTAL OFFICE POINT SOURCE CATEGORY 441.10 Applicability. (a) Except as provided in paragraphs (c), (d), and (e) of this section, this part applies to dental dischargers. (b) Unless otherwise
More information2013 USP Chapter <797> Compliance Survey & Current Practice Standards
2013 USP Chapter Compliance Survey & Current Practice Standards Kenneth S. Latta, BS, RPh Gates Healthcare Associates, Inc Hillsborough, NC We Welcome Your Questions You can submit questions throughout
More informationDOELAP On-Site Assessment Requirements Checklist Page 1 of 24 Participant:
DOELAP On-Site Assessment Requirements Checklist Page 1 of 24 General Requirements Y, N, N/A Demonstration of Conformance G.1 Latest version of protocols or procedures G.2 Latest version of dosimeter specifications
More informationRadiation Safety Procedures for the Use of Sources of Ionising Radiation. Trinity College, Dublin.
Radiation Safety Procedures for the Use of Sources of Ionising Radiation. Trinity College, Dublin. (Amended and updated by the College RPO, Mr. Tom Merriman in Aug 2014) SCOPE AND APPLICABILITY These procedures
More informationTIP NO AEROSOLIZED DRUGS TECHNICAL INFORMATION PAPER NO PURPOSE.
AEROSOLIZED DRUGS TECHNICAL INFORMATION PAPER NO. 56-088-0618 PURPOSE. Healthcare workers risk exposure to exhaled aerosolized drugs along with infectious airborne pathogens during administration and routine
More informationSingle market, regulatory environment, industries under vertical legislation Pharmaceuticals : regulatory framework and market authorisations
EUROPEAN COMMISSION ENTERPRISE DIRECTORATE-GENERAL Single market, regulatory environment, industries under vertical legislation Pharmaceuticals : regulatory framework and market authorisations Brussels,
More informationHEARING CONSERVATION PROCEDURE
HEARING CONSERVATION PROCEDURE 1. PURPOSE The purpose of this procedure is to prevent permanent and temporary occupational hearing loss that may result from impulsive, intermittent or continuous noise
More informationRadiation Safety for Safety Wardens
Environmental Health, Safety & Risk Management Health Physics Services Unit Radiation Safety for Safety Wardens - Orientation Session - Mohamad Houssam Tamim University Radiation Safety Officer B.E. Communications
More informationBiosafety Basics. Patrick Stockton, Director, Office of Biosafety Biosafety Community Liaison Committee June 26, 2017
Biosafety Basics Patrick Stockton, Director, Office of Biosafety Biosafety Community Liaison Committee June 26, 2017 What is Biosafety? The discipline that addresses how to provide guidance and assistance
More informationHearing Conservation Program
Hearing Conservation Program Revised: September 2017 2009-2017. University of New Hampshire Office of Environmental Health and Safety. All rights reserved. The most current version of this document can
More informationIncreased Microbiological Challenge Test with Bunsen Burner Inside the Cabinet
Increased Microbiological Challenge Test with Bunsen Burner Inside the Cabinet Introduction Bunsen Burner is the most frequently used apparatus in the laboratory as a source of heat. Typically used inside
More informationJury Recommendations Concerning the Death of Mr. John Wilson. The following recommendations are not presented in any particular order of priority.
Jury Recommendations Concerning the Death of Mr. John Wilson The following recommendations are not presented in any particular order of priority. 1. We the jury recommend: That the recommendations of the
More informationMANUFACTURING OPERATING STANDARDS AND RESTRICTIONS FOR COMMERCIAL CANNABIS OPERATIONS IN CITY OF CARSON
MANUFACTURING OPERATING STANDARDS AND RESTRICTIONS FOR COMMERCIAL CANNABIS OPERATIONS IN CITY OF CARSON A commercial cannabis operation engaged in manufacturing shall operate in conformance with both the
More informationInstallation Instructions
Instructions Midrange Self-Contained Unit Accessory: Indeeco Electric Heat Used with Models SCWJ, SCRJ 3, 5, 7.5, 10, 12, and 15 Tons AO and later design sequence SAFETY WARNING Only qualified personnel
More informationQUALITY CONTROL IN CYTOLOGY
27 QUALITY CONTROL IN CYTOLOGY 27.1 INTRODUCTION Cytopathologists are concerned about and committed to quality assurance and quality control in their laboratories. These practices include, among others,
More informationProcedure Number 310 TVA Safety Procedure Page 1 of 6 Hearing Conservation Revision 0 January 6, 2003
Procedure Number 310 TVA Safety Procedure Page 1 of 6 Hearing Conservation Revision 0 January 6, 2003 1. Purpose 1.1. The purpose of this procedure is to establish a TVA Hearing Conservation Program (HCP)
More informationA day in the life of an EHS Rep.
A day in the life of an EHS Rep. The EHS Rep Role of the EHS Rep created as part of MIT s EHS Management System. What are the responsibilities of the EHS Rep? Becoming an effective EHS Rep. EHS Management
More informationIntrinsically Safe Ultrasonic Testers: How important are they?
Intrinsically Safe Ultrasonic Testers: How important are they? Introduction The use of ultrasonic devices for non-destructive testing (NDT) has become more common in recent years as equipment has increased
More informationHearing Conservation Program Evaluation Checklist
Hearing Conservation Program Evaluation Checklist Training and Education Yes No N/A Comments 1. Is training conducted at least once a year? 2. Is the training provided by a qualified instructor? 3. Is
More informationHealth Services. Procedure Manual
Management of Adult Safety Net Vaccine Program All Clinic Sites To ensure uniform management of this resource throughout the agency. REPORT THROUGH AN AGENCY COORDINATOR. 1) Designated staff positions/persons
More informationRAPID Meeting. February 2018
RAPID Meeting February 2018 Agenda 2017 Annual Inspection Results and 2018 Priorities InfoEd Updates Refrigerator and Freezer Monitoring Program Lessons Learned Program New EHS Customer Satisfaction Survey
More informationTERMS AND CONDITIONS NATIONAL GOOD LABORATORY PRACTICE (GLP) COMPLIANCE MONITORING AUTHORITY
TERMS AND CONDITIONS OF NATIONAL GOOD LABORATORY PRACTICE (GLP) COMPLIANCE MONITORING AUTHORITY FOR OBTAINING AND MAINTAINING ITS GLP CERTIFICATION BY A TEST FACILITY Document No.GLP-101 Version/Issue
More informationCommitted to Environment, Health, & Safety
Committed to Environment, Health, & Safety Environment, Health, and Safety Management System and Policy of W. R. Grace & Co. November 8, 2018 The Grace Environment, Health, and Safety Management System,
More informationUni-directional Airflow Systems Working Height Velocity (WHV) Gordon Farquharson July 2017
Uni-directional Airflow Systems Working Height Velocity (WHV) Gordon Farquharson July 2017 Agenda: Uni-directional Airflow Systems Regulatory requirements & expectations. Measurement methods. Location
More informationHearing Conservation Plan
Hearing Conservation Plan TUFTS ENVIRONMENTAL HEALTH AND SAFETY SEPTEMBER 2018 Table of Contents I. Objective...3 II. Assignment of Responsibility...3 A. Department Chairpersons, Directors or designated
More informationRadiation Safety Refresher Training for Prepared by Sue Dupre Radiation Safety Officer
Radiation Safety Refresher Training for 2014 Prepared by Sue Dupre Radiation Safety Officer Topics Radiation safety staffing New training requirements Radioactive waste Surveying lab coats Wearing safety
More informationBiosafety in the Animal Setting. Tina Bogac Institutional Biosafety Officer
Biosafety in the Animal Setting Tina Bogac Institutional Biosafety Officer May 27, 2009 Biohazards and Biosafety Risk groups/risk assessment Biosafety/animal biosafety levels Essential work practices Biosafety
More informationPROCEDURE TITLE: BLOOD BORNE PATHOGENS EXPOSURE CONTROL PLAN PROCEDURE NO.: 5.21:1
PROCEDURE TITLE: BLOOD BORNE PATHOGENS EXPOSURE CONTROL PLAN PROCEDURE NO.: 5.21:1 RELATED POLICY: 5.21REV PAGE NO.: 1 OF 9 RESPONSIBLE ADMINISTRATOR(S): VPF&A/EHS EFECTIVE DATE: 07/11/14 NEXT REVIEW DATE:
More informationDivision of Research University Policy
Division of Research University Policy SUBJECT: Effective Date: Policy Number: SATELLITE ANIMAL HOUSING FACILITIES June 24, 2016 Supersedes: August 22, 2014 1 5 Responsible Authorities: Vice President,
More informationImplementation Guide for the DoseControl Dosimetry System
1.0 SCOPE The GEX DoseControl System is intended for use as a single dosimetry system solution, specifically developed to satisfy the generic dosimetry needs of radiation sterilization application users
More informationEyewash & Emergency Shower Equipment (Plumbed) Academic Affairs Laboratories of Ferris State University
EYEWASH & EMERGENCY SHOWER SECURED DOCUMENT Academic Affairs Laboratory Safety Eyewash & Emergency Shower Equipment (Plumbed) Academic Affairs Laboratories of Ferris State University Number: AALSD-2-50-1001
More informationBest Theratronics Annual Compliance Report
Best Theratronics Annual Compliance Report - 2015 License: NSPFOL-14.01/2019 Licensing period: January 1, 2015 to Dec 31, 2015 Submitted: March 30, 2016 Executive Summary Best Theratronics received a Class
More informationAdministrative Procedure
Durham Catholic District School Board The Board Title: Eyewash Stations and Safety Showers Procedure #: AP414-12 Administrative Area: Policy Reference: Human Resources and Administrative Services Emergency
More informationEnvironmental Health & Safety Policy Manual
Environmental Health & Safety Policy Manual Issue Date: 1/23/2014 Policy # EHS-400.14 Hearing Conservation Program 1.0 PURPOSE: To establish policy that defines the minimum requirements for the LSUHSC
More informationThis program is designed to prevent hearing loss for students, staff and employees while engaged in universitysponsored
Hearing Conservation University of Tennessee Safety Program IH-010 Document Contact: EHS-General Safety Date effective: January 1, 2009 Revision Date: April 2, 2015 Purpose This program is designed to
More informationEast Carolina University
East Carolina University Office of Environmental Health & Safety 211 S Jarvis Street, Suite 102 Greenville, NC 27858 P: (252) 328-6166 F: (252) 737-1458 www.ecu.edu/oehs Hearing Conservation Program ii
More informationARKANSAS STATE UNIVERSITY GOVERNING PRINCIPLES FOR THE USE OF CONTROLLED SUBSTANCES IN RESEARCH
ARKANSAS STATE UNIVERSITY GOVERNING PRINCIPLES FOR THE USE OF CONTROLLED SUBSTANCES IN RESEARCH 1.0 INTRODUCTION Arkansas State University (ASU) is committed to enhancing the growth of research and other
More informationSOUTHERN UTAH UNIVERSITY S WRITTEN HEARING CONSERVATION PROGRAM December 2017
SOUTHERN UTAH UNIVERSITY S WRITTEN HEARING CONSERVATION PROGRAM December 2017 1.0 PURPOSE: The objective of the Southern Utah University hearing conservation program is to minimize occupational hearing
More informationB. Tasks and Procedures where employees, students or contractors can be exposed to bloodborne pathogens:
Page 1 of 6 BLOODBORNE PATHOGEN PROGRAM INTRODUCTION The intended purpose of this document is to comply with OSHA s Occupational Exposures to Bloodborne Pathogens in Title 29 Code of Federal Regulations
More informationCity of Montpelier, Vermont The Smallest Capital City in the United States BLOODBORNE PATHOGENS EXPOSURE CONTROL PLAN AND PROCEDURES
City of Montpelier, Vermont The Smallest Capital City in the United States BLOODBORNE PATHOGENS EXPOSURE CONTROL PLAN AND PROCEDURES Last Updated June 19, 2003 1 Bloodborne Pathogens Exposure Control Plan
More information