Smile Beautifully With Sustainable Aesthetic Solutions

Size: px
Start display at page:

Download "Smile Beautifully With Sustainable Aesthetic Solutions"

Transcription

1 Smile Beautifully With Sustainable Aesthetic Solutions

2 Sustainable Aesthetics Clinicians require solutions that can meet the clinical challenge of providing aesthetic outcomes that are sustainable. BIOMET 3i introduces a portfolio of sustainable aesthetic solutions for laboratories and clinicians. These solutions combined with the proven 3i T3 multi-surface topography, provide flexibility and aesthetic results that are sustainable. The definitive prosthetic solutions incorporate 3i SureSeal TM technology with the BIOMET 3i Gold-Tite Screw, increasing the seal integrity * of the Certain connection - minimizing microleakage and leveraging platform switching benefits. Smile Beautifully with Sustainable Aesthetic Solutions BIOMET 3i provides a comprehensive portfolio of surgical and restorative treatment options with 3i SureSeal Technology to assist in achieving longterm aesthetic results. Prosthetic Selection and Placement Wide-ranging portfolio of restorative solutions Prosthetic Planning The BellaTek Encode Impression System Implant Placement Implant design and surface topography Peri-Implant Health Management The 3i T3 Implant Management System Site Preparation Comprehensive selection of regenerative products * Byrne D, Jacobs S, O Connell B, Houston F, Claffey N. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies. J. Prosthodont May Jun;15(3):

3 Sustainable Aesthetics Product Portfolio Patients specific CAD/CAM BellaTek Abutments provide anatomical margins and profiles for improved aesthetics. Custom restorations with BIOMET 3i UCLA Castable Abutments BELLATEK CAD/CAM ABUTMENTS UCLA ABUTMENTS BellaTek Encode Healing Abutments provide optimized solutions to clinicians by eliminating in most cases the need for implant level impressions.* Key benefits include: Hard-tissue and Soft-tissue Maintenance Patient Specific Abutments Traditional Impressions or Intraoral Scanning BELLATEK ENCODE HEALING ABUTMENTS Contemporary Hybrid 3i T3 Implants facilitate sustainable aesthetics through Dual Acid-Etched (DAE) surface technology and integrated platform switching. 3i T3 TAPERED IMPLANTS Endobon Xenograft Granules OsseoGuard and OsseoGuard Flex Membranes Safescraper Bone Scraper ENDOBON XENOGRAFT GRANULES Manufacturer: BIOMET France Sarl. OSSEOGUARD AND OSSEOGUARD FLEX MEMBRANES Manufacturer: Collagen Matrix, Inc., Oakland, NJ * Procedure may vary based on patient and clinical variables. Not all cases can be performed without implant level impressions.

4 The BIOMET 3i new FlexLink TiBase provides material flexibility for screwretained and cement-retained restorations GOLD-TITE SCREW FLEXLINK TM TiBASE GINGIHUE ABUTMENTS The BIOMET 3i SureSeal TM Connection with Gold-Tite Screw Technology provides up to 113% greater Certain Implant/Abutment clamping force than an uncoated screw in bench testing.* 1 PEEK & Titanium Temporary Cylinders for soft-tissue sculpting during healing in single or multi-unit cases PREFORMANCE PEEK & TITANIUM TEMPORARY CYLINDERS 3i T3 PARALLEL WALLED IMPLANTS One study shows that some implants with the BIOMET 3i integrated platform switching feature demonstrated crestal bone loss as low as 0.37mm.** 2 3i T3 Implants incorporate this same feature. The 3i T3 Implant utilizes the proven OSSEOTITE Surface technology at the coronal aspect of the implant. In a five-year study, the dual acid-etched surface of the OSSEOTITE Implant presented no increased risk of peri-implantitis or soft-tissue complications versus a machined surface. 3 SAFESCRAPER BONE SCRAPER Manufacturer: META Advanced Medical Technology, Reggio Emilia, Italy 1 Suttin Z, Towse R. Effect of abutment screw design on implant system seal performance. Presented at the European Association for Osseointegration, 20th Annual Scientific Meeting; October 2012; Copenhagen, Denmark. * Bench testing; not necessarily indicative of clinical outcomes. ** Results are not necessarily typical, indicative or representative of all recipient patients. 2 Östman PO, Wennerberg A, Ekestubbe A, Albrektsson T. Immediate occlusal loading of NanoTite prevail implants: A prospective 1-year clinical and radiographic study. Clin Implant Dent Relat Res Mar;12(1): Zetterqvist L, Feldman S, Rotter B, Vincenzi G, Wennström JL, Chierico A, Stach RM and Kenealy JN. A prospective, multicenter, randomized-controlled 5-year study of hybrid and fully etched implants for the incidence of peri-implantitis. J Periodontol 2010 April;81: Dr. Kenealy, Dr. Stach, Mr. Suttin and Mr. Towse contributed to the above research while employed by BIOMET 3i. Dr. Östman and Dr. Zetterqvist have financial relationships with BIOMET 3i LLC resulting from speaking engagements, consulting engagements and other retained services.

5 Implant/Abutment 3i SureSeal TM Technology BIOMET 3i SureSeal technology is designed for seal integrity through the implant/ abutment connection. This is achieved with a combination of the BIOMET 3i Gold-Tite Screw with the Certain Internal Connection and precision manufacturing. Implant/abutment seal strength The combination of the Certain Internal Connection and the Gold- Tite Screw provides a robust implant/ abutment junction (IAJ) interface through exacting tolerances and proprietary technology that generates increased clamping forces. Implant/abutment clamping force Gold-Tite Surface lubrication allows the screw to rotate further, increasing clamping force and maximizing abutment stability. 4 Molecular and Bacterial Leakage Test * Al-Jadaa A, * Attin T, Peltomäki T, Schmidlin PR. Comparison of three in vitro implant leakage testing methods. Clin Oral Impl Res. 00, 2013, 1 7. Aim of the bench study was to develop a customized and standardized measurement device allowing repetitive non-destruction evaluation of implant leakage. Seal Strength Test ** Zach Suttin, Ross Towse, Joell Cruz Astra Tech Nobel Biocare BIOMET 3i Molecular Bacterial MOLECULAR & BACTERIAL LEAKAGE Pre-clinical studies are not necessarily indicative of clinical results. Screw A bench study assessed the Implant-Abutment Junction (IAJ) seal robustness of industry-leading dental implant systems subjected to a dynamic loading test 5 SEAL STRENGTH Implant Thommen SPI Astra Tech TM Straumann 3i T3 Element OsseoSpeed TM Bone Level With DCD Pre-clinical studies are not necessarily indicative of clinical results. 4 Byrne D, Jacobs S, O Connell B, Houston F, Claffey N. Preloads generated with repeated tightening in three types of screws used in dental implant assemblies. J. Prosthodont May Jun;15(3): Suttin Z, Towse R, Cruz J. A novel method for assessing implantabutment connection seal robustness. Poster Presentation: Academy of Osseointegration, 27th Annual Meeting; March 2012; Phoenix, AZ. Mr. Cruz, Mr. Suttin and Mr. Towse contributed to the above research while employed by BIOMET 3i. Dr. Attin and Dr. Patrick R. Schmidlin have financial relationships with BIOMET 3i LLC resulting from speaking engagements, consulting engagements and other retained services. * Primary researcher s PhD fellowship was supported by BIOMET 3i LLC. Three implant systems were tested (n=20, 4 of each group, which were negative controls). The research was funded by BIOMET 3i LLC. Poster presentation can be reviewed at: Poster_Al-Jadaa_et_al_GELT.pdf. ** Poster presentation can be reviewed at: P16-Suttin.pdf

6 BIOMET 3i offers a family of synergistic system solutions to help you and your patients achieve beautiful, confident and healthy smiles. Smile Beautifully Smile Confidently Smile Healthy For more information regarding Smile Therapy TM System Solutions, please contact your local BIOMET 3i Sales Representative. Global Headquarters 4555 Riverside Drive Palm Beach Gardens, FL Outside the U.S.: Fax: EC REP BIOMET 3i Dental Ibérica S.L. WTC Almeda Park, Ed. 4, Planta 2 C/Tirso de Molina, , Cornellà de Llobregat (Barcelona) Spain Phone: Fax: Join Us Follow Us Watch Us Download It All trademarks herein are the property of BIOMET 3i LLC unless otherwise indicated BIOMET 3i LLC. Endobon is a trademark of BIOMET Deutschland GmbH and Safescraper is a trademark of CGM S.P.A. This material is intended for clinicians only and is NOT intended for patient distribution. This material is not to be redistributed, duplicated or disclosed without the express written consent of BIOMET 3i. For additional product information, including indications, contraindications, warnings, precautions and potential adverse effects, please visit the BIOMET 3i Website: ART1258EU REV A 5/15

FlexLink TiBase. Sustainable Aesthetic Solution

FlexLink TiBase. Sustainable Aesthetic Solution FlexLink TiBase Sustainable Aesthetic Solution FlexLink TiBase Design Sustainable Aesthetic Solution The 3i T3 Implant s macrodesign and multi-surface topography help to facilitate aesthetic patient outcomes.

More information

FlexLink TiBase. Sustainable Aesthetic Solution

FlexLink TiBase. Sustainable Aesthetic Solution FlexLink TiBase Sustainable Aesthetic Solution FlexLink TiBase For Certain And External Hex Implant Systems The FlexLink TiBase The FlexLink TiBase is designed for digital and traditional procedures with

More information

LDAC Laboratory Designed Abutments For Competitive Systems. Precision Engineered

LDAC Laboratory Designed Abutments For Competitive Systems. Precision Engineered LDAC Laboratory Designed Abutments For Competitive Systems Precision Engineered LDAC Precision Engineered, Laboratory Designed Abutments For Competitive Implant Systems Clinicians have a need for high-quality

More information

Implant And Abutment Level Impressions

Implant And Abutment Level Impressions Implant And Abutment Level Impressions Implant And Abutment Level Impressions Pick-Up Impression Copings Certain Internal Connection is illustrated below. 1. Select the proper Pick-Up Impression Coping

More information

IOS & The Sirona Connect System Clinician Procedure

IOS & The Sirona Connect System Clinician Procedure Clinician Procedure Surgeon (Please ensure that these instructions are forwarded to the restorative clinician.) STEP 1: Select a BellaTek Encode Healing Abutment with the appropriate restorative platform

More information

Laboratory Solutions. Optimization By Design

Laboratory Solutions. Optimization By Design Laboratory Solutions Optimization By Design Digital Dentistry Solutions Business Optimization With BellaTek Digital Dentistry Solutions Optimize the solutions you give to your customers with BellaTek premium

More information

Smile Confidently With DIEM 2. Melissa DelMastro. Immediate Full Arch Rehabilitation

Smile Confidently With DIEM 2. Melissa DelMastro. Immediate Full Arch Rehabilitation Smile Confidently With DIEM 2 Immediate Full Arch Rehabilitation Immediate Full Arch Rehabilitation * Edentulism and failing dentition continue to be major health challenges affecting millions of people

More information

Laboratory Designed Abutments (LDA) & Laboratory Designed Abutments For Competitive Systems (LDAC) Quick Reference Guide

Laboratory Designed Abutments (LDA) & Laboratory Designed Abutments For Competitive Systems (LDAC) Quick Reference Guide Laboratory Designed Abutments (LDA) & Laboratory Designed Abutments For Competitive Systems (LDAC) Quick Reference Guide Table Of Contents BellaTek Laboratory Designed Abutments (LDA) & BIOMET 3i Laboratory

More information

Don t Let Life Pass You By Because Of Oral Bone Loss

Don t Let Life Pass You By Because Of Oral Bone Loss Don t Let Life Pass You By Because Of Oral Bone Loss Ask For Dental Implant Solutions From BIOMET 3i Scan With Your Smartphone! In order to scan QR codes, your mobile device must have a QR code reader

More information

Zfx GenTek Genuine Restorations and Open Digital Workflows. Easy, fast, genuine.

Zfx GenTek Genuine Restorations and Open Digital Workflows. Easy, fast, genuine. Zfx GenTek Genuine Restorations and Open Digital Workflows Easy, fast, genuine. Premium implants deserve premium prosthetic components. For long-term clinical success, it is essential that the interface

More information

The Tapered Implant Slim Surgical Kit. Kit Assembly

The Tapered Implant Slim Surgical Kit. Kit Assembly The Tapered Implant Slim Surgical Kit Kit Assembly The Tapered Implant Slim Surgical Kit The Tapered Implant Surgical Kit is designed to provide a compact set of instrumentation for placing 3.25mm and

More information

LOCATOR Overdenture Implant System

LOCATOR Overdenture Implant System LOCATOR Overdenture Implant System Product Ordering Information Manufactured by ZEST Anchors Distributed by: The LOCATOR Overdenture Implant System Each package includes your choice of a 2.4mm or 2.9mm

More information

SPECIAL SUPPLEMENT. Inside this issue: 2014 No. 3. Peri-implant disease Implant surface: An evolution Summaries of select scientific publications

SPECIAL SUPPLEMENT. Inside this issue: 2014 No. 3. Peri-implant disease Implant surface: An evolution Summaries of select scientific publications www.jird.com SPECIAL SUPPLEMENT Inside this issue: Peri-implant disease Implant surface: An evolution Summaries of select scientific publications Official Publication of The Institute for Implant and Reconstructive

More information

LOCATOR Overdenture Implant System

LOCATOR Overdenture Implant System LOCATOR Overdenture Implant System Product Ordering Information Manufactured by ZEST Anchors Distributed by: LOCATOR Overdenture Implant System Surgical Instrument Kit Schematic 07357 08926 07366 07374

More information

Editorial Dental implant system design and its potential impact on the establishment and sustainability of aesthetics Richard J. Lazzara, DMD, MScD

Editorial Dental implant system design and its potential impact on the establishment and sustainability of aesthetics Richard J. Lazzara, DMD, MScD www.jird.com Editorial Dental implant system design and its potential impact on the establishment and sustainability of aesthetics Richard J. Lazzara, DMD, MScD Official Publication of The Institute for

More information

TSV BellaTek Laboratory Solutions. Optimization By Design

TSV BellaTek Laboratory Solutions. Optimization By Design TSV BellaTek Laboratory Solutions Optimization By Design Digital Dentistry Solutions for TSV Implants Business Optimization With TSV BellaTek Digital Dentistry Solutions Optimize the solutions you give

More information

REGENERATION BY DESIGN

REGENERATION BY DESIGN REGENERATION BY DESIGN ALLOGRAFT, XENOGRAFT, PUTT Y & BIOACTIVE GLASS FOR BONE REGENERATION INSTRUMENTS FOR COLLECTING BONE BARRIER MEMBRANES FOR GUIDED REGENERATION GUIDED IMPLANT TREATMENT Wide Selection

More information

T3 Short Implants. Implants & Instrumentation

T3 Short Implants. Implants & Instrumentation T3 Sort Implants Implants & Instrumentation Implant Treatment Options for Vertical Heigt Deficiencies Te T3 Sort Implant s lengt and features are designed to provide an implant treatment option in some

More information

SPECIAL SUPPLEMENT. Inside this issue: 2014 No. 2. Abstracts from Selected Publications and Poster Presentations BIOMET 3i T3 Implants

SPECIAL SUPPLEMENT. Inside this issue: 2014 No. 2. Abstracts from Selected Publications and Poster Presentations BIOMET 3i T3 Implants www.jird.com SPECIAL SUPPLEMENT Inside this issue: s from Selected Publications and Poster Presentations BIOMET 3i T3 Implants Official Publication of 2014 No. 2 The Institute for Implant and Reconstructive

More information

Scanners From BIOMET 3i. Optimization By Design

Scanners From BIOMET 3i. Optimization By Design Scanners From BIOMET 3i Optimization By Design Increase Productivity With Dental Scanners From Make an investment to increase your productivity by purchasing a 3Shape Dental Scanner from BIOMET 3i. Purchasing

More information

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations 2 Abutments for all indications Comprehensive and effective the Nobel Biocare abutment portfolio. The Nobel

More information

16 www.inclusivemagazine.com Maximizing Clinical Flexibility with the Open Platform Inclusive Tooth Replacement Solution by Tarun Agarwal, DDS, PA Go online for in-depth content The Inclusive Tooth Replacement

More information

SIMPLANT Guided Surgery delivering restorative-driven implant treatment

SIMPLANT Guided Surgery delivering restorative-driven implant treatment SIMPLANT Guided Surgery delivering restorative-driven implant treatment SIMPLANT the key to unlocking digital potential As part of the DENTSPLY Implants Digital Solutions portfolio, SIMPLANT digital implant

More information

Simplant. Guided Surgery. delivering restorative driven implant treatment

Simplant. Guided Surgery. delivering restorative driven implant treatment Simplant Guided Surgery delivering restorative driven implant treatment Simplant the key to unlocking digital potential As part of the Denstsply Sirona Implants Digital Solutions offering, Simplant delivers

More information

Natural Tapered Implant Primary Implant Stability Starts With The BIOMET 3i Tapered Implant System

Natural Tapered Implant Primary Implant Stability Starts With The BIOMET 3i Tapered Implant System Natural Tapered Implant Primary Implant Stability Starts With The BIOMET 3i Tapered Implant System BIOMET 3i s Tapered Implant provides for primary stability through its macrogeometric design. This Tapered

More information

Table of Contents. 1 Immediate occlusal loading of NanoTite PREVAIL Implants: A prospective 1-year clinical and radiographic study

Table of Contents. 1 Immediate occlusal loading of NanoTite PREVAIL Implants: A prospective 1-year clinical and radiographic study Table of Contents 1 Immediate occlusal loading of NanoTite PREVAIL Implants: A prospective 1-year clinical and radiographic study 3 Immediate provisionalization of NanoTite Implants in support of single-tooth

More information

Titanium Base abutments plus screw and associated restorative and dental laboratory components.

Titanium Base abutments plus screw and associated restorative and dental laboratory components. Instructions for use Titanium Base abutments plus screw and associated restorative and dental laboratory components. Description: Titanium Base with screw for Individual abutments under CE-Series, CL-

More information

Navigator System Model-Based Surgery Manual

Navigator System Model-Based Surgery Manual Looking For Guided Surgery Without CT Guidance? Try Navigator Model-Based Surgery Today! Model-Based Surgery Manual Accurate Treatment Pre- Operative Planning Minimally Invasive Approach Immediate Provisionalization

More information

When It Clicks, It s Seated. You re Certain. The Next-Generation Internal Connection System

When It Clicks, It s Seated. You re Certain. The Next-Generation Internal Connection System When It Clicks, It s Seated. You re Certain. The Next-Generation Internal Connection System Certain Seating Flexible Placement Uncompromised Stability Proven Predictability Simple Tools, Broad Options

More information

Description: Prosthetic Components for dental restoration under CE-Series, CL- Series, CN-Series, CH-Series, CF-Series, CR-Series, CS-Series.

Description: Prosthetic Components for dental restoration under CE-Series, CL- Series, CN-Series, CH-Series, CF-Series, CR-Series, CS-Series. Instructions for use Components for dental restoration. Description: Components for dental restoration under CE-Series, CL- Series, CN-Series, CH-Series, CF-Series, CR-Series, CS-Series. Indications: Abutment

More information

A shield never to be broken On1 concept

A shield never to be broken On1 concept A shield never to be broken On1 concept Gain peace of mind The On1 Base has a unique prosthetic connection, ensuring that only precision-engineered Nobel Biocare restorations are used. F a cos( ρ ) cos(

More information

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER Product Catalogue 1 Product Chart Follow the lines to see which products that fits both diameters and which that are special. In true OSPOL philosophy, most of the instruments and abutments fits both diameters.

More information

introduction to BioHorizons prosthetics

introduction to BioHorizons prosthetics to BioHorizons prosthetics why choose BioHorizons prosthetics? BioHorizons offers a broad array of abutments for a wide range of restorative applications and individual needs including the versatile 3inOne

More information

Welcome to DENTSPLY Implants

Welcome to DENTSPLY Implants Welcome to DENTSPLY Implants As a dental professional involved with implant therapy, replacing missing teeth is often just the beginning. In fact, you are restoring happiness and quality of life for your

More information

surgical and prosthetic options & impression technique overview

surgical and prosthetic options & impression technique overview surgical and prosthetic options & impression technique overview surgical options Multiple surgical protocols are used to achieve the prosthetic outcome of choice. The technique selected may be dependent

More information

Inside this issue: SPECIAL SUPPLEMENT, JIRD No. 1, T3 Implants A Scientific Compendium. Official Publication of Biomet 3i LLC No.

Inside this issue: SPECIAL SUPPLEMENT, JIRD No. 1, T3 Implants A Scientific Compendium. Official Publication of Biomet 3i LLC No. www.jird.com SPECIAL SUPPLEMENT, JIRD No. 1, 2017 Inside this issue: T3 Implants A Scientific Compendium Official Publication of Biomet 3i LLC. 2017 No. 1 The Journal of Implant and Reconstructive Dentistry

More information

NobelProcera Implant Bar Overdenture complete range of fixed and removable solutions.

NobelProcera Implant Bar Overdenture complete range of fixed and removable solutions. NobelProcera Implant Bar Overdenture EXPERIENCE THE NEW WORLD OF CAD/CAM DENTISTRY 2 NobelProcera Implant Bar Overdenture NobelProcera Implant Bar Overdenture complete range of fixed and removable solutions.

More information

» For multi-unit restorations -

» For multi-unit restorations - » For multi-unit restorations - conventional or digital «Multi-Unit Abutments 2 The Multi-unit product range is being contiunally expanded to include other abutment series. Available for a large number

More information

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants Very small abutment head easy and secure handling Ankylos The SmartFix concept Prosthetic solution on angled implants Stable prosthetic fit The area supporting the prosthesis is extended distally by the

More information

NobelReplace Conical Connection Product overview

NobelReplace Conical Connection Product overview NobelReplace Conical Connection Product overview High primary stability, even in compromised bone situations1 The tapered implant body is designed for high primary stability and is ideal for Immediate

More information

NobelActive Product overview

NobelActive Product overview NobelActive Product overview High primary stability even in demanding situations NobelActive s expanding tapered implant body condenses bone gradually while the apex with drilling blades enables a smaller

More information

Soft Tissue Transfer Utilizing Digital Impressions of Anterior Implants

Soft Tissue Transfer Utilizing Digital Impressions of Anterior Implants Soft Tissue Transfer Utilizing Digital Impressions of Anterior Implants Pacific Coast Society for Prosthodontics Anchorage, Alaska June 28, 2013 Kenneth F. Hinds DDS Traditional(Analog) ImpressionTechnique

More information

More than pure esthetics. The natural and strong solution.

More than pure esthetics. The natural and strong solution. More than pure esthetics. The natural and strong solution. Expand your patient pool with an innovative solution. With the Straumann PURE Ceramic Implant, clinicians have an additional option to convince

More information

Watson Dental Lab Fixed Hybrid Protocol

Watson Dental Lab Fixed Hybrid Protocol Watson Dental Lab Fixed Hybrid Protocol Watson Dental Lab has put Protocols in place to: Ensure maximum quality and fit of the final restoration. Maximize Dr. /Patient/ Lab communication and participation

More information

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix

NEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix NEW The SmartFix Concept Prosthetic solution on tilted implants SmartFix The SmartFix Concept Prosthetic solution on tilted implants The SmartFix Concept is an effective and time-saving technique for immediate

More information

PHILOSOPHY SWISS QUALITY PERFORMANCE

PHILOSOPHY SWISS QUALITY PERFORMANCE SYSTEM OVERVIEW PHILOSOPHY TRI Dental Implants is an innovative provider of dental implant solutions from Switzerland. Join our unique approach in implant dentistry! Founder & CEO Tobias S. Richter 100%

More information

cement-retained crown using the Laser-Lok Easy Ti temp abutment and PEEK plastic sleeves

cement-retained crown using the Laser-Lok Easy Ti temp abutment and PEEK plastic sleeves cement-retained crown using the Laser-Lok Easy Ti temp abutment and PEEK plastic sleeves temporary restorations cement-retained crown using the Laser-Lok Easy Ti temp abutment and PEEK plastic sleeves

More information

User Manual Complete Prosthetic Kit (CPK)

User Manual Complete Prosthetic Kit (CPK) User Manual Complete Prosthetic Kit (CPK) The Complete Prosthetic Kit is designed to enable easy impression and transfer technique and to prevent the need to remove and to re-tighten the abutments. Advantages

More information

open tray technique using the direct pick-up coping

open tray technique using the direct pick-up coping open tray technique using the direct pick-up coping impression techniques open tray technique using the direct pick-up coping Use this technique to make a single or multiple-unit, implant-level impression

More information

for individual abutment design large glue surface, so durable solid connection to the base conventional usable and also for CAD/CAM process

for individual abutment design large glue surface, so durable solid connection to the base conventional usable and also for CAD/CAM process For implant supported individual hybrid abutments BENEFITS: engaged for individual abutment design large glue surface, so durable solid connection to the base conventional usable and also for CAD/CAM process

More information

Product Information. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance. The NEW. Variobase family members

Product Information. Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance. The NEW. Variobase family members Product Information Straumann Variobase Beyond a common Ti-base. Efficiency and flexibility in balance. The NEW Variobase family members Straumann Variobase for Crown AS Angled Solution Straumann Variobase

More information

This recommendation outlines the requisite steps for the optimal use of the BEGO CADPositioner.

This recommendation outlines the requisite steps for the optimal use of the BEGO CADPositioner. This recommendation outlines the requisite steps for the optimal use of the BEGO CADPositioner. 1. The scanner must be calibrated in accordance with the manufacturer s specifications before it is used.

More information

ß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note:

ß For cement-retained crowns and bridges. Note: synocta cementable abutments. ß Can be especially helpful with large multi-unit cases Note: Choosing the correct Straumann abutment for crowns, bridges, and bars Straumann abutments are torqued to 35 Ncm by using the ratchet with torque control device and the appropriate abutment driver. Abutments

More information

COMPUTER-GENERATED ABUTMENTS USING A CODED HEALING ABUTMENT: A TWO-YEAR PRELIMINARY REPORT

COMPUTER-GENERATED ABUTMENTS USING A CODED HEALING ABUTMENT: A TWO-YEAR PRELIMINARY REPORT COMPUTER-GENERATED ABUTMENTS USING A CODED HEALING ABUTMENT: A TWO-EAR PRELIMINAR REPORT Dean C. Vafiadis, DDS* VAFIADIS 19 7 Z AUGUST This article presents a preliminary clinical evaluation following

More information

Straumann Original Clinical Review. General Information

Straumann Original Clinical Review. General Information Straumann Original Clinical Review General Information Perfect, precise components match Proven mechanical performance Long-term clinical effect PROVEN MECHANICAL PERFORMANCE A number of studies have investigated

More information

Product Information for Labs. etkon ident Perfectly versatile. Performance you can rely on.

Product Information for Labs. etkon ident Perfectly versatile. Performance you can rely on. Product Information for Labs etkon ident Perfectly versatile. Performance you can rely on. BENEFIT FROM THE BEST OF BOTH WORLDS Versatility Simplicity Industry-leading manu facturing standards Variety

More information

ONE SOLUTION FOR ALL YOUR NEEDS

ONE SOLUTION FOR ALL YOUR NEEDS ONE SOLUTION FOR ALL YOUR NEEDS JUST LIKE YOU, WE WORK WITH ONE PURPOSE IN MIND: TO ALLOW YOUR PATIENTS TO HAVE NEW REASONS TO SMILE EVERY DAY. And with this goal in mind we developed the Alvim implant.

More information

SwissPlant Prosthetic Catalog. SwissPlant

SwissPlant Prosthetic Catalog. SwissPlant SwissPlant Prosthetic Catalog Contoured Snap-On Angled Contoured Ball Attachment Gold/Plastic Castable Locator Attachment Plastic Temporary Screw Receiving Plastic Non-Engaging Castable Narrow Titanium

More information

Simplicity without compromise

Simplicity without compromise New Simplicity without compromise ASTRA TECH Implant System EV 2 Join the EVolution Simplicity without compromise We are pleased to introduce the next step in the continuous evolution of the ASTRA TECH

More information

NobelParallel Conical Connection Product overview

NobelParallel Conical Connection Product overview NobelParallel Conical Connection Product overview Access to innovative restorative solutions Take advantage of innovative solutions available only for the internal conical connection, such as the cement-free

More information

Proven stability, high esthetics NobelReplace Conical Connection

Proven stability, high esthetics NobelReplace Conical Connection Proven stability, high esthetics NobelReplace Conical Connection Proven tapered implant body with a tight sealed connection NobelReplace Conical Connection combines the original tapered implant body with

More information

Prothesis. For SHELTA implants

Prothesis. For SHELTA implants Prothesis For SHELTA implants XA posts for cemented prosthesis These posts, made of Gr. 5 titanium, allow cemented prosthesis to be fitted using the One-Abutment-One-Time technique, in which the XA post

More information

cement-retained single crowns using cementable abutments

cement-retained single crowns using cementable abutments cement-retained single crowns using cementable abutments cement-retained restorations cement-retained single crowns using cementable abutments Cement-retained implant restorations are similar to conventional

More information

Restorative Manual. Flexibility By Design

Restorative Manual. Flexibility By Design Restorative Manual Flexibility By Design Important Product Information Biomet 3i Restorative Products For detailed product information on all Biomet 3i Restorative Products, refer to the Biomet 3i Restorative

More information

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions INTRODUCTION synocta Meso abutment for cement-retained restorations 1 The synocta Meso abutments, available

More information

A novel technique for fabrication of immediate provisional restorations

A novel technique for fabrication of immediate provisional restorations Clinical A novel technique for fabrication of immediate provisional restorations Pär-Olov Östman 1 Prosthetic rehabilitation of the edentulous patient with implant-supported restorations is a commonly

More information

Restorative Manual. April

Restorative Manual. April Restorative Manual April 2014 800-407- 3379 www.glidewelldirect.com Introducing Inclusive Prosthetic Components Founded in 2006 with the goal of expanding the availability of comprehensive dental implant

More information

NEODENT GRAND MORSE IMPLANT SYSTEM GREATNESS IS AN ACHIEVEMENT.

NEODENT GRAND MORSE IMPLANT SYSTEM GREATNESS IS AN ACHIEVEMENT. NEODENT GRAND MORSE IMPLANT SYSTEM GREATNESS IS AN ACHIEVEMENT. NEODENT GRAND MORSE NIMPLANT SYSTEM GREATNESS IS AN ACHIEVEMENT. The Neodent Grand Morse Implant System is the achievement of more than 20

More information

CAD/CAM SMARTbase Beauty Done Better

CAD/CAM SMARTbase Beauty Done Better CAD/CAM SMARTbase Beauty Done Better Tools Legacy InterActive SMARTbase. Beauty Done Better. Implant Direct s SMARTbase CAD/CAM abutments combine superior aesthetics for your patient and more freedom of

More information

4-unit bridge supported by 2 implants using digital workflow

4-unit bridge supported by 2 implants using digital workflow Melbourne Bayside Dental Specialists Dr. Philip Tan 4-unit bridge supported by 2 implants using digital workflow Solutions featured: 3Shape TRIOS 3Shape Dental System 3Shape Implant Studio Case information

More information

Implant Restorations: A Step-By-Step Guide

Implant Restorations: A Step-By-Step Guide Implant Restorations: A Step-By-Step Guide Drago, Carl DDS, MS ISBN-13: 9780813828831 Table of Contents Contributors. Foreword. Acknowledgments. Chapter 1. Introduction To Implant Dentistry. 1. Introduction.

More information

Straumann Screw-retained Prosthetics

Straumann Screw-retained Prosthetics Straumann Screw-retained Prosthetics Straumann Screw-retained Abutments Straumann Screw-retained abutments Indication and product features Abutments for fixed screw-retained restorations; for multi-unit

More information

Restoring Quality Of Life. Zimmer Biomet Dental Implants. A Better Treatment Option

Restoring Quality Of Life. Zimmer Biomet Dental Implants. A Better Treatment Option Restoring Quality Of Life Zimmer Biomet Dental Implants A Better Treatment Option Dental Implants A Better Treatment Option What Are Dental Implants? A dental implant is a small anchor made of titanium

More information

Platform overview. cara I-Bridge Overview of platforms and systems. Giving a hand to oral health.

Platform overview. cara I-Bridge Overview of platforms and systems. Giving a hand to oral health. Platform overview I-Bridge Overview of platforms and systems Giving a hand to oral health. I-Bridge Implant System Platform I-Bridge regular I-Bridge angled Digital Design I-Pack I-Flex Ankylos Balance

More information

Where technology meets dentistry INNOVATION. at a GLANCE

Where technology meets dentistry INNOVATION. at a GLANCE Where technology meets dentistry INNOVATION at a GLANCE ABOUT PALTOP Paltop is a premium manufacturer of dental implants that strives to provide highest quality products in the dental arena. Leveraging

More information

closed tray technique using the indirect transfer coping

closed tray technique using the indirect transfer coping closed tray technique using the indirect transfer coping impression techniques closed tray technique using the indirect transfer coping Use this technique to make a single or multiple-unit, implant-level

More information

Multi-unit abutment open tray technique using the direct pick-up coping

Multi-unit abutment open tray technique using the direct pick-up coping Multi-unit abutment open tray technique using the direct pick-up coping impression techniques Multi-unit abutment open tray technique using the direct pick-up coping Use this technique to make an impression

More information

SPECIALIST IN CUSTOMIZED PROSTHETICS

SPECIALIST IN CUSTOMIZED PROSTHETICS STRAUMANN CARES digital solutions SPECIALIST IN CUSTOMIZED PROSTHETICS Excellent solutions with Straumann Specialist in customized prosthetics Digitalizing your workflow Attaining an accurate restoration

More information

More than a short implant.

More than a short implant. Straumann Standard Plus Short Implant More than a short implant. A new world of possibilities. More than a less invasive solution. A practice differentiator. IMPROVE PATIENT ACCEPTANCE Clinicians around

More information

STRAUMANN CARES CUSTOMIZED PROSTHETIC SOLUTIONS

STRAUMANN CARES CUSTOMIZED PROSTHETIC SOLUTIONS STRAUMANN CARES CUSTOMIZED PROSTHETIC SOLUTIONS PROSTHETIC SOLUTIONS ONE-STEP RESTORATIONS CARES X-Stream CUSTOMIZED ABUTMENTS CARES Variobase Abutment CARES Abutment, titanium CARES Abutment, ZrO 2 SCREW-RETAINED

More information

verification jig fabrication

verification jig fabrication verification jig fabrication full-arch restorations verification jig fabrication Use this technique to verify and achieve passive fitting metal framework for a bridge, hybrid prosthesis or for an overdenture

More information

PROSTHETIC EFFICIENCY. Straumann Angled Solutions (AS) Flexibility and precision from a different angle

PROSTHETIC EFFICIENCY. Straumann Angled Solutions (AS) Flexibility and precision from a different angle PROSTHETIC EFFICIENCY Straumann Angled Solutions (AS) Flexibility and precision from a different angle ORIGINAL Leverage the precise fit and the quality of the original Straumann connection 2 Straumann

More information

*The interlocking of the newly formed cement line matrix of bone with the implant surface.

*The interlocking of the newly formed cement line matrix of bone with the implant surface. *The interlocking of the newly formed cement line matrix of bone with the implant surface. The Revolutionary NanoTite Implant A Bone Bonding Surface Microtopography Of The OSSEOTITE Implant Combined With

More information

UFII : Unique Fixture, 2 nd Generation. UFII Design Characteristics

UFII : Unique Fixture, 2 nd Generation. UFII Design Characteristics UFII : Unique Fixture, 2 nd Generation UFII Design Characteristics 1. Hybrid SLA Surface Treatment 2. Tapered-Straight Combined Shape 3. Hex Internal Connection 4. Dual Morse Tapered Connection (11 Morse)

More information

Bridging the Gap Between Original and Multi-Platform Systems.

Bridging the Gap Between Original and Multi-Platform Systems. Product Information Straumann CARES Screw-Retained Bars & Bridges Bridging the Gap Between Original and Multi-Platform Systems. CARES SRBB solutions are compatible with the following implant systems: Neodent

More information

TruAbutment Digital Solutions

TruAbutment Digital Solutions TruAbutment Digital Solutions CEREC Solution TruAbutment Inc. 17742 Cowan Irvine, CA 92614 cerec@truabutment.com T : 714. 956.1488 F : 714. 956. 1491 truabutment.com Tru Scan Post Kit Tru Scan Post GH

More information

Simplicity without compromise Astra Tech Implant System EV

Simplicity without compromise Astra Tech Implant System EV Astra Tech Implant System Simplicity without compromise Astra Tech Implant System EV 2 Join the EVolution Simplicity without compromise We are pleased to introduce the next step in the continuous evolution

More information

NobelProcera Product Overview

NobelProcera Product Overview NobelProcera Product Overview TM EXPERIENCE THE NEW WORLD OF CAD/CAM DENTISTRY Most versatile product and material portfolio Latest production technology for Precision Milled Restorations PMR Cutting-edge

More information

screw-retained crown using a PEEK temporary abutment

screw-retained crown using a PEEK temporary abutment screw-retained crown using a PEEK temporary abutment temporary restorations screw-retained crown using a PEEK temporary abutment Use this technique for the fabrication of short term (30 days), screw-retained

More information

NobelActive. The NobelActive technical story

NobelActive. The NobelActive technical story NobelActive The NobelActive technical story The NobelActive technical story NobelActive origins The life cycle of NobelActive began following years of research and development on a self-drilling and bone-condensing

More information

Basic information on the. Straumann Pro Arch TL. Straumann Pro Arch TL

Basic information on the. Straumann Pro Arch TL. Straumann Pro Arch TL Basic information on the Straumann Pro Arch TL Straumann Pro Arch TL Contents 1. Introduction 2 1.1 Discover more treatment options with the 4 mm Short Implant 2 2. Technical information 3 3. Step-by-step

More information

Platform overview. cara I-Bridge Overview of platforms and systems. Giving a hand to oral health.

Platform overview. cara I-Bridge Overview of platforms and systems. Giving a hand to oral health. Platform overview I-Bridge Overview of platforms and systems Giving a hand to oral health. I-Bridge Implant System Platform I-Bridge regular I-Bridge angled Digital Design I-Pack I-Flex Ankylos Balance

More information

SIC invent. SIC P2F Abutment Dr. Galip Gurel From the gingiva shaper to a provisional crown to the final aesthetic restoration

SIC invent. SIC P2F Abutment Dr. Galip Gurel From the gingiva shaper to a provisional crown to the final aesthetic restoration SIC invent SIC P2F Abutment Dr. Galip Gurel From the gingiva shaper to a provisional crown to the final aesthetic restoration SIC P2F Abutment Dr. Galip Gurel P2F PROVISIONAL 2 FINAL From the gingiva shaper

More information

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

The LOCATOR concept. Simplicity and versatility for prosthesis fixation The concept Simplicity and versatility for prosthesis fixation The concept Experience the freedom in prosthesis fixation Simple and secure fixation of implant-supported prostheses is essential for successful

More information

the way to straumann cares abutments

the way to straumann cares abutments the way to straumann cares abutments solutions for dental laboratories 2 Why choose Straumann CARES Abutments Each patient is unique and each clinical situation is different. with Straumann CARES Abutments,

More information

MIS Implants Technologies Ltd. All rights reserved. AKE T IMPLE

MIS Implants Technologies Ltd. All rights reserved. AKE T IMPLE MIS Implants Technologies Ltd. All rights reserved. AKE T IMPLE TABLE OF CONTENTS P. 4-5 P. 6-7 P. 8-9 P. 10-11 P. 12-13 P. 14-15 P. 16-17 P. 18-19 P. 20-21 P. 22-23 P. 24-25 P. 26-27 P. 28-29 P. 30-31

More information

Product Information. Straumann CARES Scan & Shape Turn into digital.

Product Information. Straumann CARES Scan & Shape Turn into digital. Product Information Turn into digital. I have been using the Scan & Shape service since its introduction by Straumann. I have found it fast, reliable and cost-effective. The ability to preview the case

More information

Straumann Dental System Indication-based prosthetic workflow. Technical Information

Straumann Dental System Indication-based prosthetic workflow. Technical Information Straumann Dental System Indication-based prosthetic workflow Technical Information Contents Tissue Level Single Crown Screw-retained 2 Tissue Level Single Crown Cement-retained 4 Tissue Level Bridge Screw-retained

More information

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G IQ IMPLANTS Smart Choice PRODUCT C ATA L O G www.iqimplants.com info@iqimplants.com 2 TABLE OF CONTENTS GENERAL Company Profile 3 IMPLANTS 5 PROSTHETICS 13 TOOLS 27 3 COMPANY PROFILE IQ Implants Ltd. reflects

More information