THE ONLY SYSTEM^ CLINICALLY PROVEN TO REDUCE HYPOGLYCAEMIA
|
|
- Oswin Thomas
- 6 years ago
- Views:
Transcription
1 THE ONLY SYSTEM^ CLINICALLY PROVEN TO REDUCE HYPOGLYCAEMIA MINIMED 640G system^ with SmartGuard technology
2 HYPOGLYCAEMIA IS CHALLENGING FOR GLYCAEMIC CONTROL 1 AND quality of life 2 Achieving good glucose control without the risk or fear of going low is a challenging balancing act for you and your patients. ON AVEraGE A PATIENT EXPERIENCEs 74% SYMPTOMATIC HYPOS PER WEEK. 1 of type 1 patients report altering insulin doses out of fear of hypoglycaemia. 3 26% of severe hypoglycaemic events lead to seizures & coma. 4 poor GLYCAEMIC control ProvIDEs risk for both development and progression of diabetes complications. 5
3 Patients with severe hypoglycaemia have a greater fear of hypos, more diabetes-related distress and poorer general emotional wellbeing. 3 38% of emergency medical service call outs for hypoglycaemia result IN hospitalisation. 6 Hypoglycaemia is the biggest barrier to good glycaemic control in patients with type 1 diabetes. It causes fear and worry for patients and is costly to our healthcare budgets. Dr Conget
4 MINIMED 640G system^ WITH SMARTGUARD PROVIDES ADVANCED PROTECTION AGAINST HYPOGLYCAEMIA 7 75% Of SMARTGUARD events did not hit the low glucose limit. 8 Based upon SmartGuard real life data from 4,818 patients * SmartGuard, our exclusive closed loop technology, provides protection against hypoglycaemia. 8 It can: HELP PREVENT severe hypoglycaemic episodes Automatically stops insulin when sensor glucose is predicted to approach a pre-set low limit. Help AVOID hyperglycaemic rebound Resumes insulin delivery when levels recover. HELP provide Better protection against lows Allows your patients to set multiple low limits throughout the day and night.
5 trust smartguard to DO THE WORk NO INCREASE IN HYPERGLYCAEMIA SmartGuard technology provides advanced protection from hypoglycaemia without significant increase in hyperglycaemia SmartGuard REAL Life PerfORMANCE DATA * High limit SmartGuard feature: On Off Sensor Glucose mmol/l Low limit Time from the Suspend event (hr) LESS GLYCAEMIC VARIABILITY Sensor Glucose values associated with automatically-resumed events showed less glycaemic variability than those associated with manually-resumed events. 7 Trust our accurate system to provide Advanced Protection for your patients (9.1% MARD). 9 * Medtronic data on file: SmartGuard technology real life data evaluated using the voluntary MiniMed 640G system uploads to CareLink Personal from Jan. 13th 2015 to Jan. 14th 2016.
6 how smartguard works Insulin suspended SmartGuard suspends insulin when sensor glucose is approaching a pre-set low limit. * SmartGuard feature: On Off predicted predicted Sensor Glucose mmol/l 4.5 SmartGuard resumes basal insulin Delivery will automatically resume if sensor glucose recover. ** 3.4 Low limit 2.3 1:00 1:30 2:00 2:30 3:00 3:30 4:00 4:30 Time of day (AM) * The dynamic suspend feature is based on certain criteria: sensor glucose must be within 3.9mmol/L of the low limit and predicted to be 1.1mmol/L above the low limit within 30 minutes AND the pump must not be in the refractory period. ** The dynamic resume feature is based on certain preset criteria: sensor glucose must be 1.1mmol/L above the preset low limit and predicted to be 2.2mmol/L above within 30 minutes AND insulin must have been suspended for at least 30 minutes. The MiniMed 640G system^ with SmartGuard significantly reduces hypoglycaemia in clinical practice and allows more time to be spent within target glycaemic range.
7 MINIMED 640G system^ greater CONVenIENCE IMPROVED DESIGN Diabetes is already complicated, your patients system shouldn t be. greater CONVENIENCE Greater and easier dosing for patients with the Bolus Wizard calculator. * Preset bolus options, personalised basal patterns and programmable reminders for easy customising of your patients therapy. Improved Design Intuitive 10 navigation for easy training. Waterproof ** allowing uninterrupted wear. Full-colour, auto-brightness display for legibility even for patients with reduced eyesight. * Calculation is based on the amount of insulin currently in the body, the amount of carbohydrates, the user s current and target blood sugar levels, their insulin-to-carb ratio and their body s sensitivity to insulin. Proper Bolus Wizard setup must be completed first. Users must input the number of carbohydrates their current blood glucose value before the Bolus Wizard can calculate the insulin users. ** Waterproof at time of manufacture up to 3.6 meters for up to 24 hours at a time. See MiniMed 640G User Guide for a complete description of the waterproof capabilities and proper use instructions.
8 MINIMED 640G system^ WITH SMARTGUARD technology it thinks insulin delivery Medtronic offers a wide range of infusion sets so that you can choose the right infusion set for your patients comfort and safety. continuous GLUCOSE MONITORING The Enlite sensor provides a reliable 9 CGM experience for your patients. 1 therapy MANAGEMENT tools CareLink TM Pro software includes insightful trend reports and therapy considerations to help you make informed treatment decisions for your patients. Blood GLUCOSE Testing Contour Next LINK 2.4 meter links wirelessly to MiniMed 640G and provides proven 11,12 testing accuracy and discreet remote bolusing. 1 Cryer, PE. Diabetologia. 2002, Jul 45(7): Hendrieckx, C. et al. Diabetes Research and Clinical Practice Fidler, C. et al. J Med Econ (5) DCCT Group. N Engl J Med Sep; 329: Skyler, JS. Edocrinol Metab Clin North Am Jun; 25(2) Villani, M. et al. Journal of Diabetes and its Complications Choudhary, P. et al. Diabetes Technol. Ther. 2016, Vol 18 (5). 8 Medtronic data on file: SmartGuard real life data. Medtronic MiniMed evaluated using the voluntary MiniMed 640G uploads to CareLink Personal from Jan. 13th 2015 to Jan. 14th Cohen, O. et al. Diabetes Technol. Ther. Feb 2016, 18(S1): A CCR Study, 2012 HFMD, Inc. Data on file at Medtronic MiniMed, Inc. Northridge, CA. 11 Bailey, T. et al. Clin Chim Acta 2015 Aug; 448: In vitro diagnostic test systemsrequirements for blood glucose monitoring systems for self-testing in managing diabetes mellitus. Geneva, Switzerland: International Organization for Standardization; ISO 15197:2013. When combined with the MiniMed 640G system and Guardian 2 Link transmitter. ^Components sold separately Medtronic Australasia Pty Ltd, 97 Waterloo Road, North Ryde NSW 2113 Australia Mail: Medtronic Diabetes, PO Box 945, North Ryde, NSW hour Toll Free: australia.diabetes@medtronic.com Facebook: YouTube: Medtronic Diabetes ANZ Safety Information: MiniMed 640G MiniMed 640G Insulin Pump system is indicated for the continuous delivery of insulin, at set and variable rates, for the management of diabetes mellitus in persons requiring insulin. In addition, the pump system is indicated for continuous or periodic monitoring of glucose levels in the fluid under the skin, and possible low and high glucose episodes. When using a sensor and transmitter, the pump displays continuous glucose values and stores this data so that it can be analyzed to track patterns and improve diabetes management. Pump history can be downloaded to a computer for analysis of historical glucose values. The continuous sensor glucose values provided by the MiniMed 640G insulin pump system are not intended to be used directly for making therapy adjustments. Rather, they provide an indication that a confirmation fingerstick measurement may be required. All therapy adjustments should be based on measurements obtained using a home glucose monitor and not based on the value displayed by the pump. For listings of indications, contraindications, precautions, warnings and parental adverse events, please refer to the instructions for use. MiniMed 640G, SmartGuard, Bolus Wizard, Guardian 2 CareLink and Enlite are Trademarks of Medtronic Inc. Bayer, Bayer Cross are trademarks of Bayer. Ascensia and CONTOUR are trademarks of Ascensia Diabetes Holdings AG. Please visit for complete details. APPROVAL # Date of prep: April 2016
WOULD YOU LIKE TO REDUCE THE FEAR OF HYPOGLYCAEMIA FOR YOUR PATIENTS?
WOULD YOU LIKE TO REDUCE THE FEAR OF HYPOGLYCAEMIA FOR YOUR PATIENTS? THE ONLY SYSTEM CLINICALLY PROVEN TO REDUCE HYPOGLYCAEMIA MINIMED 640G SYSTEM WITH SMARTGUARD TECHNOLOGY 1 HYPOGLYCAEMIA IS CHALLENGING
More informationWOULD YOU LIKE MORE CONFIDENCE IN YOUR HYPOGLYCAEMIC CONTROL? SMARTGUARD. PROVIDES PREDICTIVE PROTECTION
WOULD YOU LIKE MORE CONFIDENCE IN YOUR HYPOGLYCAEMIC CONTROL? SMARTGUARD. PROVIDES PREDICTIVE PROTECTION 1,2 MINIMED 640G WITH SMARTGUARD HAVE YOU CONSIDERED THE REAL IMPACT HYPOGLYCAEMIA HAS ON YOUR LIFE?
More informationMINIMED 640G WITH SMARTGUARD GIVES YOU CONFIDENCE TO TAKE CONTROL OF YOUR DIABETES
MINIMED 640G WITH SMARTGUARD GIVES YOU CONFIDENCE OF YOUR DIABETES HAVE YOU CONSIDERED THE REAL IMPACT HYPOS HAVE ON YOUR LIFE? AN ESTIMATED 1 HOUR EVERY DAY IS LOST TO THE MANAGEMENT OF 43% OF PEOPLE
More informationMORE TIME TO BE. The MiniMed 670G system. Less time thinking about managing your diabetes. *1 More time focusing on your day. 2,3
MORE TIME TO BE Leanne. MiniMed TM 670G Ambassador The MiniMed 670G system Less time thinking about managing your diabetes. *1 More time focusing on your day. 2,3 *Some user interaction required. THE SYSTEM
More informationDISCOVER THE POWER OF CONNECTION MINIMED 640G
DISCOVER THE POWER OF CONNECTION MINIMED 640G INSULIN PUMP THERAPY CHANGING LIVES TODAY Has your child just been diagnosed with insulin dependent diabetes? Or perhaps they ve been on multiple daily injection
More informationPATIENT TRAINING CHECKLIST MINIMED 670G SYSTEM
Technical Training Insulin Pump Infusion Set: Insulin Pump Model: BASIC FEATURES Patient has demonstrated understanding of: Button Functions Home Screen Menu review Status Screens Battery type/insertion
More informationDISCOVER THE POWER OF CONNECTION MINIMED 640G
DISCOVER THE POWER OF CONNECTION MINIMED 640G INSULIN PUMP THERAPY CHANGING LIVES TODAY Have you just been diagnosed with insulin dependent diabetes? Perhaps you ve been on multiple daily injection therapy
More informationUSING THE MINIMED 670G SYSTEM. Instructions for the Experienced MiniMed 630G System User
USING THE MINIMED 670G SYSTEM Instructions for the Experienced MiniMed 630G System User This is a supplemental guide. For complete instructions and safety information, please see your MiniMed 670G System
More informationUSING THE MINIMED 670G SYSTEM
USING THE MINIMED 670G SYSTEM Instructions for the Experienced MiniMed 630G System User USING THE MINIMED 670G SYSTEM: INSTRUCTIONS FOR THE EXPERIENCED USER Checklist for starting on your MiniMed 670G
More informationGIVE YOUR PATIENTS CERTAINTY
GIVE CERTAINTY Pictured: The Renouf brothers all live with T1D TECH UPGRADE CGM SUBSCRIPTION INTRODUCING THE TECH UPGRADE CGM SUBSCRIPTION FROM MEDTRONIC HOW SMARTGUARD TM WORKS In Australia people generally
More informationCARELINK PERSONAL ACTIONABLE INSIGHTS FOR BETTER DIABETES MANAGEMENT CARELINK REPORTS GUIDE
CARELINK PERSONAL ACTIONABLE INSIGHTS FOR BETTER DIABETES MANAGEMENT CARELINK REPORTS GUIDE CARELINK PERSONAL ACTIONABLE INSIGHTS FOR BETTER DIABETES MANAGEMENT As part of your diabetes therapy you have
More informationINSPIRED BY GIVE HIM MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.
INSPIRED BY GIVE HIM MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs. * NOW APPROVED FOR AGES 7 AND UP. Waterproof to a depth
More informationINSPIRED BY GIVE HER MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs.
INSPIRED BY GIVE HER MORE. The MiniMed 670G system is the world s first insulin delivery system that automatically adapts to your child s needs. * NOW APPROVED FOR AGES 7 AND UP. MORE TIME HERE TO USING
More informationUnderstanding the CareLink TM Therapy Management Dashboard Report
3 2 1 5 6 7 4 1 This is a great place to start recognizing trends. In this example you may see plenty of events that result in a low glucose trend. A low glucose is identified as a value less than 70mg/dL.
More informationGETTING STARTED WITH CONTINUOUS GLUCOSE MONITORING
GETTING STARTED WITH CONTINUOUS GLUCOSE MONITORING TABLE OF CONTENTS GETTING STARTED WITH CONTINUOUS GLUCOSE MONITORING SECTION 1: Introduction to Continuous Glucose Monitoring... 3 SECTION 2: Sensor Glucose
More informationRELEASED. Clearing your active insulin
To clear all your settings: 1. Make sure the pump is not connected to your body. 2. Go to the Manage Settings screen. Menu > Utilities > Manage Settings 3. Simultaneously press and hold and until the Manage
More informationReport Reference Guide
Report Reference Guide How to use this guide Each type of CareLink report and its components are described in the following sections. Report data used to generate the sample reports was from sample patient
More informationCareLink. software REPORT REFERENCE GUIDE. Management Software for Diabetes
CareLink Management Software for Diabetes software REPORT REFERENCE GUIDE How to use this guide Each type of CareLink report and its components are described in the following sections. Report data used
More informationTHE MINIMED 670G SYSTEM SCHOOL NURSE GUIDE
THE MINIMED 670G SYSTEM SCHOOL NURSE GUIDE Indicated for type 1 patients 14 and over. Prescription required. WARNING: Medtronic performed an evaluation of the MiniMed 670G system and determined that it
More informationGETTING STARTED WITH THE MINIMED 640G SYSTEM
GETTING STARTED WITH THE MINIMED 640G SYSTEM TABLE OF CONTENTS INTRODUCING THE MINIMED 640G SYSTEM MiniMed Care...3 Welcome...4 The Delivery of Insulin...7 Menu Map...8 GETTING STARTED WITH THE MINIMED
More informationImagine a world... Believe in better control. MiniMed Veo Paradigm System A Step-by-Step Guide
Imagine a world... Believe in better control MiniMed Veo Paradigm System A Step-by-Step Guide Imagine a world... Where you can exercise whenever you want and not have to carb load or worry about hypos.
More informationRELEASED. first steps. Icon Icon name What it means
Icon Icon name What it means Connection The connection icon appears green when the Sensor feature is on and your transmitter is successfully communicating with your pump. The connection icon appears gray
More informationMiniMed 640G System Intelligent for Better Control
Getting Started with the MiniMed 640G System Intelligent for Better Control Table Of Contents Introduction I MiniMed Care Introducing the MiniMed 640G System MiniMed Care...3 Welcome...4 The Delivery of
More informationPumps & Sensors made easy. OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University
Pumps & Sensors made easy OPADA ALZOHAILI MD FACE Endocrinology Assistant Professor Wayne State University DeFronzo RA. Diabetes. 2009;58:773-795. Ominous Octet Relationship of b-cell Dysfunction and Development
More informationUNCOVERING THE BENEFITS OF THE ACCU- CHEK BOLUS ADVISOR MICHAEL PORTER CDE
UNCOVERING THE BENEFITS OF THE ACCU- CHEK BOLUS ADVISOR MICHAEL PORTER CDE 1 LEARNING OBJECTIVES By the end of this session participants should be able to understand: The benefits of bolus advisors The
More informationDiabetes Technology Update. Sarah Konigsberg, MD Diabetes & Endocrine Assoc. April 7, 2018
Diabetes Technology Update Sarah Konigsberg, MD Diabetes & Endocrine Assoc. April 7, 2018 Disclosures None No future technologies are FDA approved Continuous Glucose Monitors Continuous Glucose Monitors
More informationArtificial Pancreas Device Systems. Populations Interventions Comparators Outcomes. pump. pump
Protocol Artificial Pancreas Device Systems (10130) Medical Benefit Effective Date: 04/01/18 Next Review Date: 01/19 Preauthorization Yes Review Dates: 03/15, 03/16, 03/17, 01/18 Preauthorization is required.
More informationInsulin Pumps and Continuous Glucose Sensors- Embracing Technology. Susan Cavalier, BS, RN, CDE Manager, Diabetes Educator Sanford Diabetes Education
Insulin Pumps and Continuous Glucose Sensors- Embracing Technology Susan Cavalier, BS, RN, CDE Manager, Diabetes Educator Sanford Diabetes Education Diabetes Management Tools in 1974 Insulin pump history
More informationWelcome to CareLink Pro
Reference Guide Welcome to CareLink Pro This guide was developed to serve as a reference for obtaining patient data and reviewing CareLink Pro reports. Getting Started with CareLink Pro Adding New Patients
More informationArtificial Pancreas Device Systems. Populations Interventions Comparators Outcomes Individuals: With type 1 diabetes
Protocol Artificial Pancreas Device Systems Medical Benefit Effective Date: 07/01/18 Next Review Date: 01/20 Preauthorization Yes Review Dates: 03/15, 03/16, 03/17, 01/18, 05/18, 01/19 Preauthorization
More informationPROTOCOL FOR HYBRID CLOSED LOOP TECHNOLOGY
PROTOCOL FOR HYBRID CLOSED LOOP TECHNOLOGY Situations Requiring Special Consideration and Resource Documents Second Edition MiniMed 67G System Medical Education TABLE OF CONTENTS A PROTOCOL FOR HYBRID
More informationInsulin Pumps Available in Canada
Insulin Pumps Available in Canada A Comparison from WaltzingTheDragon.ca *Accu-Chek Animas Ping/Vibe Medtronic Minimed 630G Omnipod ABOUT FORM: Is the insulin pump Tubing- Free? Is the pump? Or Water-Resistant?
More informationAdvances in Technology in the Treatment of Diabetes Mellitus 2017 How far have we come-how far are we going? Is there a final frontier?
Advances in Technology in the Treatment of Diabetes Mellitus 2017 How far have we come-how far are we going? Is there a final frontier? Alan B Schorr DO FAAIM FACE www.sugardoc.com abs@sugardoc.com Disclosures
More informationMINIMED 640G SYSTEM^ Getting Started WITH CONTINUOUS GLUCOSE MONITORING
MINIMED 640G SYSTEM^ Getting Started WITH CONTINUOUS GLUCOSE MONITORING let s get started! Table of Contents Section 1: Continuous Glucose Monitoring System Components... 2 Section 2: Sensor Glucose (SG)
More informationWHAT CAN I DO TO REDUCE MY RISK OF DEVELOPING THE COMPLICATIONS OF TYPE 1 DIABETES?
Christian In better control with his pump since 2012 WHAT CAN I DO TO REDUCE MY RISK OF DEVELOPING THE COMPLICATIONS OF TYPE 1 DIABETES? Many people with Type 1 diabetes worry about potential long-term
More informationDiabetes Management: Current High Tech Innovations
Diabetes Management: Current High Tech Innovations How Far We ve Come in the Last 40 Years William V. Tamborlane, MD Department of Pediatrics Yale School of Medicine Disclosures I am a consultant for:
More informationGetting Started. Learning Guide. with Insulin Pump Therapy. PUMP Foundations. for the MiniMed 530G with Enlite
Getting Started with Insulin Pump Therapy for the MiniMed 530G with Enlite Learning Guide PUMP Foundations MiniMed 530G Insulin Pump Settings Form: We recommend that you record all settings on this form
More informationNDSS Helpline
Continuous GLUCOSE MONITORING A guide to using CGM for children and young people with type 1 diabetes NDSS Helpline 1300 136 588 ndss.com.au The National Diabetes Services Scheme is an initiative of the
More informationComparative table of insulin pumps
Comparative table of insulin pumps Pumps reviewed: insight (Roche Veo 640G Mylife OmniPod Mylife S () The first stop for professional medicines advice www.sps.nhs.uk Authored May 2018 Insight OmniPod S
More informationReport Reference Guide. THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1
Report Reference Guide THERAPY MANAGEMENT SOFTWARE FOR DIABETES CareLink Report Reference Guide 1 How to use this guide Each type of CareLink report and its components are described in the following sections.
More informationAbbott FreeStyle Libre Pro System
, the Professional CGM Abbott FreeStyle Libre Pro Reader Kit includes: Reader, USB cable, interactive tutorial on USB, and power adapter, user s manual, Quick Start Guide, Quick Reference Guide Kit includes:
More informationContinuous Glucose Monitoring
Continuous Glucose Monitoring Information about fully-subsidised continuous glucose monitoring for children and young people with type 1 diabetes Continuous glucose monitoring (CGM) can help in managing
More informationArtificial Pancreas Device System (APDS)
Medical Policy Manual Durable Medical Equipment, Policy No. 77 Artificial Pancreas Device System (APDS) Next Review: October 2019 Last Review: October 2018 Effective: November 1, 2018 IMPORTANT REMINDER
More informationPredicts and helps prevent lows with. zero fingersticks NOW FEATURING BASAL-IQ TECHNOLOGY
Predicts and helps prevent lows with * zero fingersticks NOW FEATURING BASAL-IQ TECHNOLOGY Basal-IQ Technology is not a substitute for active self-management of your diabetes. Please see back cover for
More informationTHERAPY MANAGEMENT SOFTWARE FOR DIABETES
THERAPY MANAGEMENT SOFTWARE FOR DIABETES Report Report Interpretation Reference Guide Guide 2009 Medtronic MiniMed. All rights reserved. 6025274-012_a CareLink Pro Report Reference Guide 0 p.2 Adherence
More informationThe pump that gets updated, not outdated. *
FULLY FUNDED for eligible patients. The pump that gets updated, not outdated. * * Charges may apply. Dexcom CGM is not currently funded and is sold separately. Small pump. Big features. The simple-to-use
More informationMiniMed 640G System Intelligent for Better Control
Getting Started with the MiniMed 640G System Intelligent for Better Control Table Of Contents Introduction I MiniMed Care Introducing the MiniMed 640G System MiniMed Care...3 Welcome...4 The Delivery of
More informationAnneli, Martina s daughter In better control with her pump since 2011 MY CHILD HAS TYPE 1 DIABETES
Anneli, Martina s daughter In better control with her pump since 2011 MY CHILD HAS TYPE 1 DIABETES Many parents whose child is diagnosed with Type 1 diabetes wonder: Why is this happening to my child?
More informationObjectives. The Problem. We ve come a LONG way, Innovations in Diabetes Care and Management. Barbara Walz, RN, BSN, CDE April 26, 2018
Objectives Innovations in Diabetes Care and Management Barbara Walz, RN, BSN, CDE April 26, 2018 1. Briefly discuss the history of diabetes management over the past 100 years 2. Describe the impact of
More informationTHERAPY MANAGEMENT SOFTWARE FOR DIABETES
THERAPY MANAGEMENT SOFTWARE FOR DIABETES Report Report Interpretation Reference Guide Guide 2007 Medtronic MiniMed. All rights reserved. 6025274-0U2 120707 CareLink Pro Report Reference Guide 0 p.2 Sensor
More informationPaolo Di Bartolo U.O di Diabetologia Dip. Malattie Digestive & Metaboliche AULS Prov. di Ravenna. Ipoglicemie e Monitoraggio Glicemico
Paolo Di Bartolo U.O di Diabetologia Dip. Malattie Digestive & Metaboliche AULS Prov. di Ravenna Ipoglicemie e Monitoraggio Glicemico Management of Hypoglycaemia.if hypoglycemia is a problem, the principles
More informationAbbott FreeStyle Libre Pro System
Professional CGM Abbott FreeStyle Libre Pro Reader Kit includes: Reader, USB cable, interactive tutorial on USB, and power adapter, user s manual, Quick Start Guide, Quick Reference Guide Kit includes:
More informationSensor-augmented pump systems provide insulin delivery
DIABETES TECHNOLOGY & THERAPEUTICS Volume 18, Number 10, 2016 Mary Ann Liebert, Inc. DOI: 10.1089/dia.2016.0216 ORIGINAL ARTICLE Effectiveness of Automated Insulin Management Features of the MiniMed c
More informationHow to Transfer Your Settings
How to Transfer Your Settings for your Replacement MiniMed 530G System Let s get started! Step 1: Before you send your original pump back, copy your current settings onto the Insulin Pump Settings Form.
More informationA pump for every body.
A quick look at Animas Vibe A pump for every body. Even for the most insulin sensitive. Every body needs accuracy. Here s why: For anyone with diabetes, having the right amount of insulin at just the right
More informationMINIMED 670G HYBRID CLOSED LOOP (HCL) IN THE FIELD
MINIMED 670G HYBRID CLOSED LOOP (HCL) IN THE FIELD USE AND EXAMPLES Rich Flores, RD Diabet es Clinical Manger Northern Minnesota/ St. Cloud WARNING: Territory Medtronic performed an evaluation of the MiniMed
More informationApproved by: Integrated Health Quality Management Subcommittee Effective Date: Department of Origin: Integrated Healthcare Services.
Reference #: MC/L008 Page: 1 of 8 PRODUCT APPLICATION: PreferredOne Community Health Plan (PCHP) PreferredOne Administrative Services, Inc. (PAS) ERISA PreferredOne Administrative Services, Inc. (PAS)
More information10:20 AM March 5, B 100% 235 u. 124 mg/dl 3 HRS INSULIN ON BOARD:
DEXCOM G5 MOBILE CGM COMPATIBLE B 100% 235 u INSULIN ON BOARD: OPTIONS 10:20 AM March 5, 2017 400 350 300 250 200 150 100 50 1.1 u 1:09 hrs BOLUS 124 mg/dl 3 HRS The pump that gets updated, not outdated.
More informationAssessing the value of the Ambulatory Glucose Profile in clinical practice
Assessing the value of the Ambulatory Glucose Profile in clinical practice STEPHAN MATTHAEI Abstract Glycated haemoglobin (HbA 1c) is a measure of mean blood glucose levels over time. It is not a good
More informationWhat is the role of insulin pumps in the modern day care of patients with Type 1 diabetes?
What is the role of insulin pumps in the modern day care of patients with Type 1 diabetes? Dr. Fiona Wotherspoon Consultant in Diabetes and Endocrinology Dorset County Hospital Fiona.Wotherspoon@dchft.nhs.uk
More informationUnderstanding the CareLinkTM Sensor Meter Overview Report: Page 1
Understanding the CareLinkTM Sensor Meter Overview Report: Page 1 Sensor & Meter Overview (1 of 3) 4-Hour Glucose Sensor Overlay - Readings & Averages (mg/dl) 1 Glucose Sensor Overlay Bedtime to Wake-Up
More informationMEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps
POLICY: PG0177 ORIGINAL EFFECTIVE: 12/01/08 LAST REVIEW: 02/13/18 MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps GUIDELINES This policy does not certify benefits or authorization
More informationAdvances Towards the Bionic Pancreas.
Advances Towards the Bionic Pancreas. Ron Brazg MD, FACE Rainier Clinical Research Center Renton, WA DISCLOSURES Rainier Clinical Research Center is an independent research facility not directly affiliated
More informationMEDTRONIC SCIENTIFIC PROGRAM
SCIENTIFIC PROGRAM ATTD 2017 15 th - 18 th PARIS, FRANCE Our vision at Medtronic is to transform diabetes care by working closely with you, so people living with diabetes can enjoy greater freedom and
More informationDiagnostics guidance Published: 12 February 2016 nice.org.uk/guidance/dg21
Integrated sensor-augmented pump therapy systems for managing blood glucose levels els in type 1 diabetes (the MiniMed Paradigm adigm Veo system and the Vibe and G4 PLATINUM CGM system) Diagnostics guidance
More informationGETTING STARTED WITH THE MINIMED 640G SYSTEM
GETTING STARTED WITH THE MINIMED 640G SYSTEM TABLE OF CONTENTS INTRODUCTION I MINIMED CARE INTRODUCING THE MINIMED 640G SYSTEM MiniMed Care...3 Welcome...4 The Delivery of Insulin...7 Menu Map...8 GETTING
More informationUNDERSTANDING THE BASIC FEATURES AND MANAGEMENT IN THE SCHOOL SETTING CHRISTINE HERTLER RN BSN CDE & MARY MCCARTHY RN CDE
UNDERSTANDING THE BASIC FEATURES AND MANAGEMENT IN THE SCHOOL SETTING CHRISTINE HERTLER RN BSN CDE & MARY MCCARTHY RN CDE The insulin pump Replaces injections Delivers insulin through a soft cannula
More informationGETTING STARTED WITH MINIMED 670G CONTINUOUS GLUCOSE MONITORING
GETTING STARTED WITH MINIMED 670G CONTINUOUS GLUCOSE MONITORING Contents Continuous Glucose Monitoring Getting started with continuous glucose monitoring Section 1: Section 2: Section 3: Section 4: Section
More informationUnderstanding the Assessment and Progress Report
Understanding the ssessment and Progress Report ssessment and Progress 8//2-8/7/2 (7 Days) 3 7/2/2-7/27/2 (7 Days) 4 25-75% -% verage 2 4: M- 5:4 M Hyperglycemic patterns() :45 PM- :3 PM 2 3 :2 M- :5 M
More informationGETTING STARTED WITH THE MINIMED 640G SYSTEM
GETTING STARTED WITH THE MINIMED 640G SYSTEM TABLE OF CONTENTS INTRODUCTION I MINIMED CARE INTRODUCING THE MINIMED 640G SYSTEM MiniMed Care... 3 Welcome... 4 The Delivery of Insulin... 7 Menu Map... 8
More informationHow to Transfer Your Settings
How to Transfer Your Settings for your Replacement Paradigm REAL-Time Revel Insulin Pump Let s get started! Step 1: Before you send your original pump back, copy your current settings onto the Insulin
More informationADA 2018 JUN 25, 2018 ORLANDO, FLORIDA
ADA 2018 JUN 25, 2018 ORLANDO, FLORIDA FORWARD LOOKING STATEMENTS This presentation contains forward-looking statements. They are based on current assumptions and expectations that involve uncertainties
More informationCAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS Annual Meeting HILTON HEAD ISLAND FRIDAY PRESENTATION
CAROLINAS CHAPTER/AMERICAN ASSOCIATION OF CLINICAL ENDOCRINOLOGISTS 2016 Annual Meeting HILTON HEAD ISLAND FRIDAY PRESENTATION September 9-11, 2016 ~ Sonesta Resort ~ Hilton Head Island, SC This continuing
More informationUniversity College Hospital. Blood glucose and HbA 1 c targets
University College Hospital Blood glucose and HbA 1 c targets Children & Young People s Diabetes Service The diabetes team at UCLH aims to help every child and young person with Type 1 Diabetes to safely
More informationGLOOKO DREAMED FOR ANDROID USER GUIDE
GLOOKO DREAMED FOR ANDROID USER GUIDE November 2018 IFU-0017 02 TABLE OF CONTENTS TABLE OF CONTENTS GENERAL INFORMATION... 2 Product Description... 2 Glooko Intended Use... 2 Dreamed Intended Use... 2
More informationGlucometers Gastrostomy Tubes Nasogastric Tubes Insulin pumps Continuous Glucose monitoring system Closed Loop Smart phones/tablets
Devices Glucometers Gastrostomy Tubes Nasogastric Tubes Insulin pumps Continuous Glucose monitoring system Closed Loop Smart phones/tablets Accuracy Glucometers The ISO (International Organization for
More informationCONTENTS Introduction 1-2 Home 3-4 Upload 5-8 Logbook 9-10 Reports 11-17
CONTENTS Introduction 1-2 Home 3-4 Upload 5-8 Logbook 9-10 Reports 11-17 Medtronic Diabetes is the world leader in insulin pump therapy and continuous glucose monitoring systems. Every day, our products
More informationREPORT INTERPRETATION
REPORT INTERPRETATION: Interpreting ipro Professional Continuous Glucose Monitoring (CGM) Reports and Making Therapy Adjustments TARGET AUDIENCE The audience for this section is physicians, mid-level practitioners,
More informationDURING TRAINING CONTINUOUS GLUCOSE MONITORING MINIMED 630G SYSTEM
DURING TRAINING CONTINUOUS GLUCOSE MONITORING MINIMED 630G SYSTEM TABLE OF CONTENTS DURING TRAINING CONTINUOUS GLUCOSE MONITORING MINIMED 630G SYSTEM Welcome... Section 1: Getting Started... Section :
More informationCGM Therapy Expert Program
CGM Therapy Expert Program PROGRAM OVERVIEW The Medtronic-Bayer CGM Therapy Expert Program is designed to update healthcare professionals on the most current scientific and technical information regarding
More informationPerformance-powered. The OneTouch. Ping insulin pump and meter-remote.
Performance-powered. The OneTouch Ping insulin pump and meter-remote. I We don t just deliver insulin. We deliver outstanding clinical performance. P36337_OTP_DetAid_OmniPodUpdate_r12.indd 1 OneTouch Ping.
More informationAnimas Vibe System World-class insulin pumping meets world-class CGM*
Animas Vibe System World-class insulin pumping meets world-class CGM* Fully integrated with Dexcom G4 PLATINUM CGM* *Continuous glucose monitoring. My Animas pump has really put me in the driver s seat
More informationDiabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond)
Diabetes II Insulin pumps; Continuous glucose monitoring system (CGMS) Ernest Asamoah, MD FACE FACP FRCP (Lond) 9501366-011 20110401 Objectives Understand the need for insulin pumps and CGMS in managing
More informationMedical Education. Personal Continuous Glucose Monitoring Protocol. Innovating for life.
Personal Continuous Glucose Monitoring Protocol A Guide to Continuous Glucose Monitoring Integrated with Insulin Pump Therapy Includes Alert and Trend Management as well as Threshold Medical Education
More informationMAKE THE CHANGE. For better control and to maintain skin health, change your infusion set and site every 2-3 days.
MAKE THE CHANGE For better control and to maintain skin health, change your infusion set and site every 2-3 days. PROBLEMS THAT CAN OCCUR AFTER 3 DAYS Why it s important to change your infusion set every
More informationCountry Health SA Local Health Network. Title: Continuous Glucose Monitoring (CGM) and Flash Glucose Monitoring (FGM) Ambulatory Service
Protocol (Clinical) Title: Continuous Glucose Monitoring (CGM) and Flash Glucose Monitoring (FGM) Ambulatory Service Protocol developed by: CHSALHN Diabetes Service Protocol Sponsor: CHSALHN, Executive
More informationDesigned with your patients lives in mind
The Accu-Chek Insight diabetes therapy system Designed with your patients lives in mind With pre-filled insulin cartridge Designed for easy patient training The Accu-Chek Insight diabetes therapy system
More informationGETTING STARTED. Continuous Glucose Monitoring MiniMed 630G System
GETTING STARTED Continuous Glucose Monitoring MiniMed 630G System WARNING: Do not use the Suspend on low feature until you have read the information in this Getting Started Guide and received instructions
More informationInsulin Pump Therapy in children. Prof. Abdulmoein Al-Agha, FRCPCH(UK)
Insulin Pump Therapy in children Prof. Abdulmoein Al-Agha, FRCPCH(UK) aagha@kau.edu.sa Highlights Evolution of insulin pump Pumps mimics Pancreas Goals of diabetes care What lowers HbA1c Criteria for selection
More informationBlood glucose Meter Roche USA V6/ PMS 287 Proof Print Number 209 Advanced Owner s Booklet
This file may not print or view at 100%. Die lines and color breaks do not print. Roche USA 50841 V6/1 06434258002 Black Proof Print Number 209 06434258002-0512 Roche USA 50841 V6/2 06434258002 Cyan Proof
More informationSet-up and special features
Set-up and special features Set Time 2 : 45 Set Date 23 Apr 202 Choose to keep your Verio IQ simple or customise it to your desire with its various features Alerts On Of f Please set with care. In the
More informationPresented by Dr. Bruce Perkins, MD MPH Dr. Michael Riddell, PhD
Type 1 Diabetes and Exercise: Optimizing the Medtronic MiniMed Veo Insulin Pump and Continuous Glucose Monitoring (CGM) for Better Glucose Control 1,2 for Healthcare Professionals Presented by Dr. Bruce
More informationGetting Started. with Continuous Glucose Monitoring. Learning Guide
Getting Started with Continuous Glucose Monitoring Learning Guide Getting Started with Continuous Glucose Monitoring Keys to Success Getting Started with CGM: Learning Guide TRENDS CGM finally lets you
More informationDesigned by Animas. Inspired by you.
Designed by Animas. Inspired by you. part of the family We re Animas. And we make insulin pumps. Diabetes is what we know. Pumps are what we do. And our commitment is to you, the people who live with Type
More informationUsing the Bolus Wizard Calculator
9501179-011 Using the Bolus Wizard Calculator Objective Describe the features and benefits of the Bolus Wizard Calculator Key Points The Bolus Wizard: Estimates high blood glucose corrections using the
More informationNEW TECHNOLOGIES FOR MANAGING DIABETES ANGELA THOMPSON DNP, FNP-C, BC-ADM, CDE, FAANP
NEW TECHNOLOGIES FOR MANAGING DIABETES ANGELA THOMPSON DNP, FNP-C, BC-ADM, CDE, FAANP No commercial support or sponsorship was received for this project I have nothing to disclose OBJECTIVES Identify at
More informationPeople with type 1 diabetes and Do It Yourself (DIY) technology solutions ABOUT THIS POSITION STATEMENT
Position Statement People with type 1 diabetes and Do It Yourself (DIY) technology solutions ABOUT THIS POSITION STATEMENT Diabetes Australia believes that people with diabetes should have choice and access
More informationMEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps
POLICY: PG0177 ORIGINAL EFFECTIVE: 12/01/08 LAST REVIEW: 05/24/18 MEDICAL POLICY Continuous Glucose Monitoring Systems and Insulin Pumps GUIDELINES This policy does not certify benefits or authorization
More informationUvA-DARE (Digital Academic Repository) The artificial pancreas Kropff, J. Link to publication
UvA-DARE (Digital Academic Repository) The artificial pancreas Kropff, J. Link to publication Citation for published version (APA): Kropff, J. (2017). The artificial pancreas: From logic to life General
More informationDIABETES & ENDOCRINE DIABETES TECHNOLOGY: HOW TO STAY CURRENT WITH ONGOING TECHNOLOGY ADVANCEMENT
DIABETES TECHNOLOGY: HOW TO STAY CURRENT WITH ONGOING TECHNOLOGY ADVANCEMENT Min-Jye Chen, MD Endocrinology Diabetes Management of the School-Aged Child Provided by Texas Children s Hospital Provider #18-267764-A
More information