MRI Checklist for MED EL CI and ABI models
|
|
- Ashlynn Stewart
- 6 years ago
- Views:
Transcription
1 MRI Checklist for MED EL CI and ABI models Mi1200 SYNCHRONY Mi1200 SYNCHRONY PIN Mi1210 SYNCHRONY ST...1 Mi1200 SYNCHRONY ABI Mi1200 SYNCHRONY PIN ABI...2 Mi1000 CONCERTO Mi1000 CONCERTO PIN SONATA...3 Mi1000 CONCERTO ABI Mi1000 CONCERTO PIN ABI...3 PULSAR C40+ C PULSAR ABI C40+ ABI...4 Please visit us at Help and assistance are always available from your local office. (English EU) 1
2 Mi1200 SYNCHRONY Mi1200 SYNCHRONY PIN Mi1210 SYNCHRONY ST MRI Checklist for MED EL CI models Mi1200 SYNCHRONY Mi1200 SYNCHRONY PIN Mi1210 SYNCHRONY ST VALID for all intracochlear electrode variants VALID for all body regions PERMITTED, static magnetic field strength 0.2 T, 1.0 T, 1.5 T, 3.0 T MAXIMUM PERMITTED SAR (at 0.2 T, 1.0 T, 1.5 T) NORMAL OPERATING MODE, i.e. MAXIMUM PERMITTED SAR (at 3.0 T) Head Whole Body <35 cm from the top of the head Whole Body 35 cm from the top of the head 1.6 W/kg 1.0 W/kg 2.0 W/kg (next bullet point) decide if the magnet should be removed Mi1200 SYNCHRONY Mi1200 SYNCHRONY PIN Mi1210 SYNCHRONY ST MAGNET REMOVAL Has the implant magnet been surgically removed? NOTE: The likelihood and intensity of auditory sensations can be reduced by selecting sequences with a lower Specific Absorption Rate (SAR) and slower gradient slew rates. HEAD ORIENTATION (only applicable at 1.0 T, 1.5 T, 3.0 T) OPTIONAL: HEAD BANDAGE A supportive head bandage over the implant using an elastic bandage wrapped tightly around the head for at least three times can optionally be used. PATIENT POSITIONING (only applicable at 1.0 T, 1.5 T, 3.0 T) Ensure straight head orientation. NOTE: When lower extremities are to be examined, it is recommended that patient s legs are positioned in the scanner first. OPERATING MODE (only applicable at 0.2 T, 1.0 T, 1.5 T) Run sequences in Normal Operating Mode only. OPERATING MODE (only applicable at 3.0 T) Apply maximum permitted SAR according to following table only: SAR (Head) SAR (Whole-Body) <35 cm from the top of the head 35 cm from the top of the head 1.6 W/kg 1.0 W/kg 2.0 W/kg ACCESSORIES (only applicable at 3.0 T) Do not utilise head transmit coils or multi-channel transmit coils. 1
3 Mi1200 SYNCHRONY ABI Mi1200 SYNCHRONY PIN ABI MRI Checklist for MED EL ABI models Mi1200 SYNCHRONY ABI Mi1200 SYNCHRONY PIN ABI VALID for ABI electrode variant VALID for all body regions PERMITTED, static magnetic field strength 0.2 T, 1.0 T, 1.5 T MAXIMUM PERMITTED SAR NORMAL OPERATING MODE, i.e. (next bullet point) decide if the magnet should be removed MAGNET REMOVAL Has the implant magnet been surgically removed? Mi1200 SYNCHRONY ABI Mi1200 SYNCHRONY PIN ABI NOTE: The likelihood and intensity of auditory sensations can be reduced by selecting sequences with a lower Specific Absorption Rate (SAR) and slower gradient slew rates. HEAD ORIENTATION (only applicable at 1.0 T, 1.5 T) OPTIONAL: HEAD BANDAGE A supportive head bandage over the implant using an elastic bandage wrapped tightly around the head for at least three times can optionally be used. PATIENT POSITIONING (only applicable at 1.0 T, 1.5 T) Ensure straight head orientation. NOTE: When lower extremities are to be examined, it is recommended that patient s legs are positioned in the scanner first. OPERATING MODE Apply Normal Operating Mode only. 2
4 Mi1000 CONCERTO Mi1000 CONCERTO PIN SONATA Mi1000 CONCERTO ABI Mi1000 CONCERTO PIN ABI MRI Checklist for MED EL CI and ABI models Mi1000 CONCERTO Mi1000 CONCERTO PIN SONATA Mi1000 CONCERTO ABI Mi1000 CONCERTO PIN ABI VALID for all electrode variants VALID for all body regions PERMITTED, static magnetic field strength 0.2 T, 1.0 T, 1.5 T MAXIMUM PERMITTED SAR NORMAL OPERATING MODE, i.e. NOTE: The likelihood and intensity of auditory sensations can be reduced by selecting sequences with a lower Specific Absorption Rate (SAR) and slower gradient slew rates. HEAD ORIENTATION (only applicable at 1.0 T, 1.5 T) Mi1000 CONCERTO Mi1000 CONCERTO PIN SONATA Mi1000 CONCERTO ABI Mi1000 CONCERTO PIN ABI HEAD BANDAGE (only applicable at 1.0 T, 1.5 T) Place a supportive headband over the implant. NOTE: The bandage may be an elastic bandage wrapped tightly around the head at least three times. PATIENT POSITIONING (only applicable at 1.0 T, 1.5 T) Align longitudinal axis of patient`s head parallel to the main magnetic field. NOTE: When lower extremities are to be examined, it is recommended that patient s legs are positioned in the scanner first to minimize any risk of weakening the implant magnet. OPERATING MODE Run sequences in Normal Operating Mode only. 3
5 PULSAR C40+ C40 PULSAR ABI C40+ ABI MRI Checklist for MED EL CI and ABI models PULSAR C40+ C40 PULSAR ABI C40+ ABI VALID for all electrode variants VALID for all body regions VALID for unilateral as well as bilateral implant provision PERMITTED, static magnetic field strength 0.2 T, 1.0 T, 1.5 T MAXIMUM PERMITTED SAR NORMAL OPERATING MODE, i.e. IMPLANT CONDITION Is the implant housing mechanically intact? (not fractured or shattered) IMPLANTATION STATUS Has the implant been implanted for at least six months? BONE THICKNESS Is the bone underneath the implant at least 0.4 mm thick? NOTE: The likelihood and intensity of auditory sensations can be reduced by selecting sequences with a lower Specific Absorption Rate (SAR) and slower gradient slew rates. HEAD ORIENTATION (only applicable at 1.0 T, 1.5 T) HEAD BANDAGE (only applicable at 1.0 T, 1.5 T) Place a supportive headband over the implant. NOTE: The bandage may be an elastic bandage wrapped tightly around the head at least three times. PULSAR C40+ C40 PULSAR ABI C40+ ABI PATIENT POSITIONING (only applicable at 1.0 T, 1.5 T) Align longitudinal axis of patient`s head parallel to the main magnetic field. NOTE: When lower extremities are to be examined, it is recommended that patient`s legs are positioned in the scanner first to minimize any risk of weakening the implant magnet. OPERATING MODE Run sequences in Normal Operating Mode only. 4
6 MED EL Elektromedizinische Geräte GmbH Fürstenweg 77a 6020 Innsbruck, Austria 5 medel.com
Cochlear Implants. Medical Procedures. for MED EL Implant Systems. AW33290_2.0 (English US)
Cochlear Implants Medical Procedures for MED EL Implant Systems AW33290_2.0 (English US) This manual provides important instructions and safety information for MED EL Implant System users who have to undergo
More informationCochlear Implants. Medical Procedures. for MED EL CI Systems. AW33290_5.0 (English US)
Cochlear Implants Medical Procedures for MED EL CI Systems AW33290_5.0 (English US) This manual provides important instructions and safety information for MED EL CI System users who have to undergo a medical
More informationMRI Safety Information for the HiRes Ultra 3D Cochlear Implant
Advanced Bionics AG Laubisrütistrasse 28 8712 Stäfa, Switzerland +41 58 928 78 00 Manufactured by: Advanced Bionics LLC California, U.S.A. +1 661 362 1400 MRI Safety Information for the HiRes Ultra 3D
More informationMED-EL Medical Electronics
Innsbruck, Austria, February 2018 PRESS INFORMATION MED-EL Medical Electronics MED-EL, headquartered in Innsbruck, Austria, is a leading provider of hearing implant systems. The privately-owned business
More informationMRI Guidelines for the Axonics Sacral Neuromodulation System
MRI Guidelines for the Axonics Sacral Neuromodulation System For Healthcare Professionals Rx only Note: This document is a supplement to the physician manuals provided with the Axonics SNM System. This
More information1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)
1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500) ONLY NEVRO CORP. All questions or concerns about Nevro products should be forwarded to: Nevro
More informationMRI GUIDELINES FOR INSPIRE THERAPY
MRI GUIDELINES FOR INSPIRE THERAPY Clinician s Manual ONLY The following is a trademark of Inspire Medical Systems, Inc.: Inspire Introduction Read the information in this manual prior to conducting an
More informationRONDO. User Manual. Cochlear Implants NOT FOR PRINT
Cochlear Implants RONDO User Manual AW9389_3.0 (English US) Table of contents 1. Table of contents 1. TABLE OF CONTENTS 1 2. INTRODUCTION 3 3. INTENDED USE INDICATIONS CONTRA-INDICATIONS 4 Intended use
More information1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500)
1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System (IPG1000 and IPG1500). ONLY NEVRO CORP. All questions or concerns about Nevro products should be forwarded to: Nevro
More informationRead this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System.
Algovita Spinal Cord Stimulation System MRI Procedure Guidelines Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System. ONLY 0300-000175-001
More informationAlgovita. MRI Procedure Guidelines. Spinal Cord Stimulation System. 201x
Algovita Spinal Cord Stimulation System MRI Procedure Guidelines Read this manual before performing an MRI scan on a patient implanted with an Algovita Spinal Cord Stimulation System. ONLY 201x Algovita
More informationMRI SureScan pacemakers & ICDs what you need to know
MRI SureScan pacemakers & ICDs what you need to know Many variables can affect the device patient s likelihood of risks w/ an MRI Type of imaging sequence Type of scanner MRI scan duration Strength of
More informationMedium External Fixator Humeral Shaft Frame. Modular frame for upper extremity use.
Medium External Fixator Humeral Shaft Frame. Modular frame for upper extremity use. Technique Guide Part of the Medium External Fixation System MRI Information Synthes Medium External Fixation devices
More informationMedium External Fixator Pediatric Femoral Shaft Frame. Using medium multi-pin clamps.
Medium External Fixator Pediatric Femoral Shaft Frame. Using medium multi-pin clamps. Technique Guide Part of the Medium External Fixation System MRI Information Synthes Medium External Fixation devices
More informationMRI for Patients with MRI-Conditional Pacing System: Radiographers Role. Lawrance Yip DM, DR, QMH
MRI for Patients with MRI-Conditional Pacing System: Radiographers Role Lawrance Yip DM, DR, QMH MRI & Pacemaker MRI is a crucial and growing imaging modality Plays an important role in clinical management
More informationExternal Distal Radius Fixator. Supplement to the 8 mm rod fixator system
External Distal Radius Fixator. Supplement to the 8 mm rod fixator system Surgical technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation
More informationFor Professionals. SYNCHRONY System In Sync with Natural Hearing
For Professionals SYNCHRONY System In Sync with Natural Hearing SYNCHRONY Cochlear Implant In Sync with Natural Hearing Smallest Titanium Implant The smallest and lightest titanium cochlear implant available
More informationLow-Profile Wrist Fixator. For stabilization of fractures of the distal radius.
Low-Profile Wrist Fixator. For stabilization of fractures of the distal radius. Technique Guide Part of the External Fixation System Low-Profile Wrist Fixator Indications Intended for stabilization of
More information*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Knee Implants
Knee Implants MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG Knee Implants *smith&nephew Supporting healthcare professionals for over 150 years Summary All knee implants of Smith
More information1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System
1.5 Tesla and 3 Tesla Magnetic Resonance Imaging (MRI) Guidelines for the Senza System ONLY 11096 Rev B 1 NEVRO CORP. All questions or concerns about Nevro products should be forwarded to: Nevro Corp.
More informationFor Professionals. SYNCHRONY System. In Sync with Natural Hearing
For Professionals SYNCHRONY System In Sync with Natural Hearing For more natural hearing in any listening environment SONNET Audio Processor RONDO Single-Unit Processor Designed for exceptional hearing
More informationImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System
ImageReady MRI Full Body Guidelines for Precision Montage MRI Spinal Cord Stimulator System CAUTION: Federal law restricts this device to sale, distribution and use by or on the order of a physician. 91035972-02
More informationCardiac Rhythm Therapy // Advanced Features // ProMRI. ProMRI. Checklist and Quick Reference Guide
Cardiac Rhythm Therapy // Advanced Features // ProMRI ProMRI Checklist and Quick Reference Guide PAGE 2 Conditions for MR scans with a BIOTRONIK ProMRI system Usage of an MR scan on a patient having an
More information*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Shoulder Implants
Shoulder Implants MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG Shoulder Implants *smith&nephew Supporting healthcare professionals for over 150 years Summary All shoulder implants
More informationQ & A: How to Safely Scan Patients with a SureScan MRI Pacemaker
Q & A: How to Safely Scan Patients with a SureScan MRI Pacemaker Patient Scheduling and Screening Q: Is there any special (other than regular MRI consent) consent form that should be signed by the patient?
More informationThe Calcaneal Plate. The Synthes non-locking solution for the Calcaneus.
The Calcaneal Plate. The Synthes non-locking solution for the Calcaneus. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation.
More information2014 AAPM 56 th Annual Meeting
2014 AAPM 56 th Annual Meeting SAM Diagnostic Radiology MR Safety - Deep Brain Stimulator and Other Neurostimulators Yunhong Shu, Ph.D. Mayo Clinic, Rochester, MN Outline Background of Neurostimulator
More informationFor Professionals. Electrode Arrays. Designed for Atraumatic Implantation Providing Superior Hearing Performance
For Professionals Electrode Arrays Designed for Atraumatic Implantation Providing Superior Hearing Performance Electrode Arrays Designed for Atraumatic Implantation Providing Superior Hearing Performance,,,
More informationMRI GUIDELINES FOR INSPIRE THERAPY
MRI GUIDELINES FOR INSPIRE THERAPY Clinician s Manual The following is a trademark of Inspire Medical Systems, Inc.: Inspire This product and/or the use of this product in a method may be covered by one
More information*smith&nephew. MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG. Hip Implants
Hip Implants MRI Safety Information & Parameters for Smith & Nephew Orthopaedics AG Hip Implants *smith&nephew Supporting healthcare professionals for over 150 years Summary All hip implants of Smith &
More informationLCP Metaphyseal Plates. For extra-articular fractures.
LCP Metaphyseal Plates. For extra-articular fractures. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Image intensifier
More informationImageReady MRI Head Only Guidelines for Spectra WaveWriter Spinal Cord Stimulator System
ImageReady MRI Head Only Guidelines for Spectra WaveWriter Spinal Cord Stimulator System CAUTION: Federal law restricts this device to sale, distribution and use by or on the order of a physician. 91171762-01
More informationWarning: Patients should not be exposed to MRI environments until the surgical site following pump implantation is fully healed.
Prometra and Prometra II Programmable Pumps Magnetic Resonance Imaging (MRI) Safety Information GENERAL MR Conditional WARNING: FAILURE TO EMPTY THE PUMP PRIOR TO EXPOSURE TO MRI ENVIRONMENT COULD RESULT
More informationDistal Radius Plate 2.4/2.7 dorsal and volar
Distal Radius Plate 2.4/2.7 dorsal and volar Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Distal Radius Plate
More informationVNS Therapy System Physician s Manual
VNS Therapy System Physician s Manual Pulse Generator Model 102 Pulse Duo Generator Model 102R Demipulse Generator Model 103 Demipulse Duo Generator Model 104 AspireHC Generator Model 105 AspireSR Generator
More informationFastFrame External Fixation System. Damage Control Surgical Technique
FastFrame External Fixation System Damage Control Surgical Technique 1 FastFrame External Fixation System Damage Control Surgical Technique Table of Contents Introduction... 2 Indications and Contradictions...
More informationUser Manual: Ives MR Conditional Cup Electrodes J.R. Ives, December 22, 2017
User Manual: Ives MR Conditional Cup Electrodes J.R. Ives, December 22, 2017 Ives EEG Solutions; 25 Storey Ave., #118, Newburyport, MA, 01950; ph: 978-358-8006; fax: 978-358-7825; www.iveseegsolutions.com
More informationFor Professionals. SYNCHRONY EAS System. In Sync with Natural Hearing
For Professionals SYNCHRONY EAS System In Sync with Natural Hearing SYNCHRONY EAS System Electric Acoustic Stimulation The SYNCHRONY EAS System combines the SONNET EAS Audio Processor with the SYNCHRONY
More informationMRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System
MRI-Ready Systems Manual MRI Procedure Information for the St. Jude Medical MR Conditional System CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician. WARNING: This
More informationSterile-Packaged Large External Fixator Kits. For treatment of long bone and pelvic fractures that require external fixation.
Sterile-Packaged Large External Fixator Kits. For treatment of long bone and pelvic fractures that require external fixation. Large External Fixator Ankle Frame Kit Large External Fixator Trauma Kit Large
More informationEasyStep. Operative technique
Operative technique EasyStep - Step staple This publication sets forth detailed recommended procedures for using Stryker Osteosynthesis devices and instruments. It offers guidance that you should heed,
More information9/27/2018. Type of Hearing Loss. Type of Hearing Loss. Type of Hearing Loss
MED-EL Mission To overcome hearing loss as a barrier to communication and quality of life. We effectively yet gently restore hearing by offering a comprehensive set of intact-skin hearing implant solutions.
More informationThe Auditory Brainstem Implant. Manchester Royal Infirmary
The Auditory Brainstem Implant Manchester Royal Infirmary What is an auditory brainstem implant (ABI)? An auditory brainstem implant (ABI) is a device that may allow a person to hear if they have had damage
More informationLarge External Fixator Modular Knee Bridge
Using Multi-pin Clamps Large External Fixator Modular Knee Bridge Surgical Technique Large External Fixator Modular Knee Bridge DePuy Synthes Large External Fixation devices are labeled MR Conditional
More informationMRI guidelines for Medtronic neurostimulation systems for chronic pain
MRI guidelines for Medtronic neurostimulation systems for chronic pain See "START HERE" section before conducting MRI. Instructions for use! USA Rx only Explanation of symbols on product or package labeling
More informationCOCHLEAR NUCLEUS IMPLANT RELIABILITY REPORT. Volume 16 December 2017
COCHLEAR NUCLEUS IMPLANT RELIABILITY REPORT Volume 16 December 2017 OUR MISSION We help people hear and be heard. We empower people to connect with others and live a full life. We transform the way people
More informationREFILL KIT For use with Prometra Programmable Infusion Systems
REFILL KIT Caution: Federal (USA) Law restricts this device to sale by or on the order of a physician. Table of Contents Contents... 3 Description... 3 Indications... 3 Contraindications... 3 Warnings...
More informationJRI Thompson Hemiarthroplasty
JRI ORTHOPAEDICS LTD 18 Churchill Way, 35A Business Park, Chapeltown, Sheffield, S35 2PY, UK Instructions for Use JRI Thompson Hemiarthroplasty Page 1 of 6 English 3 Page 2 of 6 Important Information Please
More informationUnderstanding Peripheral
Patient Information Guide Understanding Peripheral Artery Disease Innova Vascular Self-Expanding Stent System Table of Contents Glossary... 2 What is Peripheral Artery Disease?... 4 Treating Peripheral
More informationButton Plate. Reinforcement for transosseous fixations.
Button Plate. Reinforcement for transosseous fixations. Product Information This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation. Image intensifier
More informationMicra MC1VR01. MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR)
Micra MC1VR01 MRI procedural information for Micra Model MC1VR01 MR Conditional single chamber transcatheter pacing device (VVIR) MRI Technical Manual The following list includes trademarks or registered
More informationAdvisa MRI and Ensura MRI SureScan pacing systems
Advisa MRI and Ensura MRI SureScan pacing systems MR Conditional dual chamber and single chamber SureScan pacing systems with SureScan leads MRI Technical Manual The following list includes trademarks
More informationCARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART
CARDIAC DEVICE MR-CONDITIONAL PRODUCT SUMMARY CHART December 2015 This chart encompasses all Medtronic cardiac devices FDA-Approved as MR Conditional and included in the MRI SureScan portfolio. If a device
More informationMagnetic resonance imaging safety of NucleusR 24 cochlear implants at 3.0 T
International Congress Series 1273 (2004) 394 398 www.ics-elsevier.com Magnetic resonance imaging safety of NucleusR 24 cochlear implants at 3.0 T F. Risi*, A. Saldanha, R. Leigh, P. Gibson Cochlear Limited,
More informationX-linked Malformation and Cochlear Implantation
X-linked Malformation and Cochlear Implantation Henrik Smeds, Jeremy Wales, Ulrika Löfkvist, Lena Anmyr, Babak Falahat, Britt-Marie Anderlid, Eva Karltorp Karolinska University Hospital Stockholm, Sweden
More informationLarge External Fixator Modular Knee Bridge. Using multi-pin clamps.
Large External Fixator Modular Knee Bridge. Using multi-pin clamps. Technique Guide Part of the Large External Fixation System Large External Fixator Modular Knee Bridge Technique Overview Insert Schanz
More informationMRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System
MRI-Ready Systems Manual MRI Procedure Information for the St. Jude Medical MR Conditional System Unless otherwise noted, indicates that the name is a trademark of, or licensed to, St. Jude Medical or
More informationMRI Procedure Information. For St. Jude Medical MR Conditional Neurostimulation Systems. Clinician's Manual
MRI Procedure Information For St. Jude Medical MR Conditional Neurostimulation Systems Clinician's Manual Unless otherwise noted, indicates that the name is a trademark of, or licensed to, St. Jude Medical
More informationFor Small-Statured Adults and Pediatric Patients. Medium External Fixator Basic Modular Frame
For Small-Statured Adults and Pediatric Patients Medium External Fixator Basic Modular Frame Surgical Technique MRI Information DePuy Synthes Medium External Fixation devices are labeled MR Conditional
More informationMEFiSTO. Monolateral External Fixation System for Trauma and Orthopaedics.
MEFiSTO. Monolateral External Fixation System for Trauma and Orthopaedics. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved by the AO Foundation.
More informationManchester Adult Cochlear Implant Programme
Manchester Royal Infirmary Manchester Adult Cochlear Implant Programme Information for Patients and Professionals Contents Introduction 3 The normal ear 4 The cochlear implant 5 The assessment procedure
More informationCardiac Rhythm Management // Manual // ProMRI. ProMRI. MR conditional device systems
Cardiac Rhythm Management // Manual // ProMRI ProMRI MR conditional device systems Table of Contents Table of Contents Version Comparison............................................ 3 Change History.....................................
More informationCochlear implants. Carol De Filippo Viet Nam Teacher Education Institute June 2010
Cochlear implants Carol De Filippo Viet Nam Teacher Education Institute June 2010 Controversy The CI is invasive and too risky. People get a CI because they deny their deafness. People get a CI because
More informationSyllabus References. Resources. Video: MRI Introduction
MRI Lesson Outline Syllabus References 9.6.4.2.5 Define precessing and relate the frequency of the precessing to the composition of the nuclei and the strength of the applied external magnetic field 9.6.4.2.6
More informationMRI Procedure Information. For St. Jude Medical MR Conditional Neurostimulation Systems. Clinician's Manual
MRI Procedure Information For St. Jude Medical MR Conditional Neurostimulation Systems Clinician's Manual Unless otherwise noted, indicates that the name is a trademark of, or licensed to, St. Jude Medical
More informationMRI-Ready Systems Manual. MRI Procedure Information for the St. Jude Medical MR Conditional System
MRI-Ready Systems Manual MRI Procedure Information for the St. Jude Medical MR Conditional System Unless otherwise noted, indicates that the name is a trademark of, or licensed to, St. Jude Medical or
More informationNucleus Reliability Report
Nucleus Reliability Report Nucleus Reliability Report Volume 10 February 2012 1 Nucleus Reliability Report February 2012 About Cochlear s reliability reporting The Nucleus Reliability Report makes available
More informationMRI SURESCAN SYSTEMS. Patient Scanning Process PATIENT PRESCREENING. SureScan Pacing, Defibrillation, and CRT-D Systems Verification
MRI SURESCAN SYSTEMS Patient Scanning Process PATIENT PRESCREENING SureScan Pacing, Defibrillation, and CRT-D Systems Verification Verify that patient has a complete SureScan pacing, defibrillation, or
More informationCOCHLEAR NUCLEUS RELIABILITY REPORT. Volume 14 February 2016
COCHLEAR NUCLEUS RELIABILITY REPORT Volume 14 February 2016 OUR MISSION We help people hear and be heard. We empower people to connect with others and live a full life. We transform the way people understand
More informationCOCHLEAR NUCLEUS IMPLANT RELIABILITY REPORT. Volume 15 January 2017
COCHLEAR NUCLEUS IMPLANT RELIABILITY REPORT Volume 15 January 2017 OUR MISSION We help people hear and be heard. We empower people to connect with others and live a full life. We transform the way people
More informationBasics of MRI Part I
Basics of MRI Part I Mathew J. Dixon, D.O. Chairman Department of Radiology Memorial Health University Medical Center Savannah, GA Objectives Brief History Concept of MRI Creation of a Magnetic Field Concepts
More informationYasargil Permanent Aneurysm Clips
Yasargil Permanent Aneurysm Clips Yasargil aneurysm clips Figure captions 1 Yasargil Phynox aneurysm clip, example of a straight clip 2 Yasargil titanium aneurysm clip, example of a straight clip 3 Yasargil
More informationEXAMPLE PROTOCOL FOR PATIENT SCANNING PROCESS
EXAMPLE PROTOCOL FOR PATIENT SCANNING PROCESS MRI SureScan Pacing, ICD, and CRT (CRT-D and CRT-P) Transvenous Implantable Cardiac Systems Timothy S. E. Albert, M.D. President CVMR Solutions, Inc. Carmel
More informationSTANDARD OPERATING PROCEDURE (SOP)
STANDARD OPERATING PROCEDURE (SOP) MRI Scanning for Patients with Cardiac Implantable Electronic Devices (Pacemakers and Implantable Cardiac Defibrillators) Effective date 05/04/2018 Version number V1.0
More informationWallFlex Biliary RX Partially Covered Stent System Prescriptive Information
Caution/Rx Only: Federal Law (USA) restricts this device to sale by or on the order of a physician. Intended Use/Indications for Use The WallFlex Biliary RX is indicated for use in the palliative treatment
More informationHearing Solutions. Product Portfolio
Hearing Solutions Product Portfolio SYNCHRONY Cochlear Implant System 2 SYNCHRONY EAS Hearing Implant System 4 MED-EL Electrode Arrays 6 BONEBRIDGE Bone Conduction Implant System 8 ADHEAR Bone Conduction
More informationThe Latest in Cochlear Implant Technology 3. Safe & Reliable Implant Design 6. In Tune with the Future 8. Comprehensive Diagnostic Toolkit 12
Cochlear Implant Main Entry: sonata Pronunciation: s -nä-t Function: noun Etymology: Latin sonare, to sound an instrumental musical composition Contents The Latest in Cochlear Implant Technology 3 New
More informationKNEE ALIGNMENT SYSTEM (KAS) MRI Protocol
KNEE ALIGNMENT SYSTEM (KAS) MRI Protocol Sample referral sticker Referral Sticker Insert here Corin 17 Bridge Street Pymble NSW Australia 2073 P: +61 (0)2 9497 7400 F: +61 (0)2 9497 7498 E: KAS.customerservice@coringroup.com
More informationCall Medtronic at 1 (800) to verify the patient s current implanted system
MRI SURESCAN SYSTEMS Patient Scanning Process Transvenous Implantable Cardiac Systems PATIENT PRESCREENING SureScan Pacing, Defibrillation, and CRT (CRT-D and CRT-P) Systems Verification Verify that patient
More informationMEDICAL POLICY SUBJECT: COCHLEAR IMPLANTS AND AUDITORY BRAINSTEM IMPLANTS. POLICY NUMBER: CATEGORY: Technology Assessment
MEDICAL POLICY PAGE: 1 OF: 5 If the member's subscriber contract excludes coverage for a specific service it is not covered under that contract. In such cases, medical policy criteria are not applied.
More informationANJON BREMER LIGHT VEST
PATENTED TECHNOLOGY, TARGETED TO YOUR NEEDS ANJON BREMER APPLICATION, REMOVAL, AND CPR INSTRUCTIONS WWW.GENERIXMEDICAL.COM INTRODUCTORY INFORMATION FOR THE ANJON BREMER MRI Safety Information: Non-clinical
More informationIMF Screw Set. For temporary, peri opera tive stabilisation of the occlusion in adults.
IMF Screw Set. For temporary, peri opera tive stabilisation of the occlusion in adults. Surgical Technique This publication is not intended for distribution in the USA. Instruments and implants approved
More informationLarge External Fixator Traveling Traction
Used to Correct Angular Deformity Large External Fixator Traveling Traction Surgical Technique Large External Fixator Traveling Traction DePuy Synthes Large External Fixation devices are labeled MR Conditional
More informationMRI Information for Medtronic Spinal and Biologics Devices
M708348B263E Rev C Release Date: 2013-02 MRI Information for Medtronic Spinal and Biologics Devices Not for Distribution in the U.S or its territories. 1 P age Table of Contents MRI Information for Medtronic
More informationLarge External Fixator Delta Frame Ankle Bridge. For staged fixation of the distal tibia.
Large External Fixator Delta Frame Ankle Bridge. For staged fixation of the distal tibia. Technique Guide Part of the Large External Fixation System Large External Fixator Delta Frame Ankle Bridge Technique
More informationANGLED BLADE PLATES FOR ADULTS
ANGLED BLADE PLATES FOR ADULTS Instruments and implants approved by the AO Foundation. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE Image intensifier control This description
More informationFor Candidates. A Lifetime of Hearing. SYNCHRONY Cochlear Implant System
For Candidates A Lifetime of Hearing SYNCHRONY Cochlear Implant System THE NEXT STEPS The Next Steps In this guide, we ll introduce you to SYNCHRONY, our latest and most advanced cochlear implant system.
More informationSafety Issue of Static Magnetic Field (1)
MRI Safety Safety Issue of Static Magnetic Field (1) Currently, typical MRI utilizes static field with strengths of 0.5 to 3 Tesla (FDA guideline is max 4 T for infants < 1 month and 8 T for others) 1
More informationInstructions for use Prodisc -C Vivo Cervical disc prosthesis
Instructions for use Prodisc -C Vivo Cervical disc prosthesis Instructions for use Prodisc-C Vivo Cervical disc prosthesis Safety precautions Please read these instructions for use, the Synthes brochure
More informationWrist Fusion Instrument and Implant Set.
Wrist Fusion Instrument and Implant Set. Surgical Technique Discontinued December 2016 DSEM/TRM/0815/0479(2) This publication is not intended for distribution in the USA. Instruments and implants approved
More informationVersion überholt. Nicht verwenden. Version obsolète. Ne pas utiliser. Versione obsoleta. Non utilizzare. Verouderde versie. Niet gebruiken.
MRI TECHNICAL GUIDE IMAGEREADY MR CONDITIONAL PACING SYSTEM REF J065, J066, J067, J175, J176, J177, J275, J276, J277, J279, L110, L111, L131, L210, L211, L231, L310, L311, L331, 4456, 4457, 4458, 4459,
More informationTissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR Imaging
Provläsningsexemplar / Preview TECHNICAL REPORT ISO/TR 16379 First edition 2014-03-01 Tissue-engineered medical products Evaluation of anisotropic structure of articular cartilage using DT (Diffusion Tensor)-MR
More informationLarge External Fixator Delta Frame Ankle Bridge. Using pin clamps with outrigger posts.
Large External Fixator Delta Frame Ankle Bridge. Using pin clamps with outrigger posts. Technique Guide Part of the Large External Fixation System Large External Fixator Delta Frame Ankle Bridge Technique
More informationLOW PROFILE NEURO. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE
LOW PROFILE NEURO This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE TABLE OF CONTENTS INTRODUCTION Low Profile Neuro Plating System 2 Intended Use, Indications, Contraindications
More informationUnderstanding Cochlear Implants
Understanding Cochlear Implants 1 Understanding Cochlear Implants Welcome. You may be wondering whether a cochlear implant is the best choice for you or someone in your life. This brochure is designed
More informationIndications and contra-indications of auditory brainstem implants. Systematic review and illustrative cases
Manuscript: Authors: Journal: Indications and contra-indications of auditory brainstem implants. Systematic review and illustrative cases Merkus P (p.merkus@vumc.nl), Di Lella F, Di Trapani G, Pasanisi
More informationDISTAL RADIUS. Instructions for Use
DISTAL RADIUS Instructions for Use CAUTION: FEDERAL LAW RESTRICTS THESE DEVICES TO SALE BY OR ON THE ORDER OF A PHYSICIAN. Table of Contents 1. INTENDED USE... 3 2. DEVICE DESCRIPTION... 3 3. METHOD OF
More informationPrometra Programmable Pump System Brief Summary
Prometra Programmable Pump System Brief Summary Indications, Safety and Warnings Product Instructions for Use and the Infumorph drug labeling must be reviewed prior to use for detailed disclosure. Caution:
More informationVA LOCKING CALCANEAL PLATES 2.7
VA LOCKING CALCANEAL PLATES 2.7 Instruments and Implants approved by the AO Foundation. This publication is not intended for distribution in the USA. SURGICAL TECHNIQUE Image intensifier control Warning
More information