1 PROSTHESIS MANUAL
2
3 INDEX PRESENTATION Pag. 05 CEMENT-SCREWED PROSTHESIS Pag. 12 INTRODUCTION PROSTHESIS MANUAL WARNINGS Pag. 06 Pag. 06 IMPRESSION TAKING: NECESSARY MATERIAL PROSTHESIS: NECESSARY MATERIAL REMOVABLE PROSTHESIS OVERDENTURES Pag. 13 IMPRESSION TAKING: NECESSARY MATERIAL PROSTHESIS: NECESSARY MATERIAL MICRODENT EKTOS MULTIFUNCTION (STRAIGHT) MICRODENT EKTOS CONICAL (STRAIGHT) WITH FLAP MICRODENT EKTOS CONICAL (STRAIGHT) WITHOUT FLAP MICRODENT EKTOS IMMEDIATE LOADING CONICAL (STRAIGHT) MICRODENT EKTOS ANGLED MICRODENT EKTOS MINI CAPITEL MICRODENT EKTOS ANGLED MINI CAPITEL MICRODENT EKTOS OSSCILIA RETENTION LABELING CODE SYMBOLOGY S IMPLANTS INSTRUCTIONS FOR USE MRI SAFETY INFORMATION SURGICAL INSTRUMENTS GUARANTEE PROGRAM Pag. 14 Pag. 15 Pag. 15 Pag. 15 Pag. 15 IMPRESSION TAKING Pag. 08 CHART OF MICRODENT EKTOS S Pag. 16 CLOSED TRAY IMPRESSION TAKING WITH MULTIFUNCTION OPEN TRAY IMPRESSION TAKING CLOSED TRAY IMPRESSION TAKING PROVISIONAL CEMENTED PROSTHESIS SINGLE CEMENTED PROSTHESIS: NECESSARY MATERIAL MULTIPLE CEMENTED PROSTHESIS: NECESSARY MATERIAL Pag. 09 Pag. 10 Microdent Cover screw Microdent Retention screw Microdent Healing abutment Microdent multifunction (straight) abutment Microdent Conical (straight) abutment with flap Microdent Conical (straight) abutment without flap Microdent Immediate loading Conical (straight) abutment Microdent Angled abutment Microdent Mini Capitel abutment Microdent Angled Mini Capitel abutment Microdent Osscilia retention abutment
4
5 PRESENTATION Implant Microdent System S.L. is a company that, from its creation in 1983, has specialized in developing, manufacturing and marketing components for odontological treatments, and, specially, oral implantology. Always striving for customer satisfaction, Microdent offers all the guarantee, both of quality and service, backed up by its long and ascending professional history in the field of oral implantology. The periodical offer of formation courses for professionals of the implantology field and the existence of a collaboration and assessment team allows Microdent to have products that verify the most strict quality parameters stablished, as well as to satisfy the needs of its clients. Microdent has modern facilities equipped with the most cutting-edge technology, thus making Microdent into one of the pioneer companies in the research and manufacture of solutions for oral implantology. The patents obtained by Microdent products demonstrate the continued dedication of the company to the research work. 5
6 Microdent With internal hexagonal connection INTRODUCTION PROSTHESIS MANUAL This manual informs dental practitioners and prosthetists of the different Microdent Implant System abutments available to make a dental prosthesis. This prosthetic manual suggests which Microdent abutment should be used depending on the situation and/or requirements of the patient. The use of the strict protocols described in this manual guarantees the efficacy of the Microdent products. WARNINGS MICRODENT EKTOS MULTIFUNCTION (STRAIGHT) A retention screw is provided in the container with the abutment. Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended. The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment. While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis. The multifunction abutment is characterized by its multiple functionality: implant holder, transfer and provisional abutment. The multifunction abutment is supplied with the implant and cover screw in their own packaging in a sterile state. The multifunction abutment is connected to the implant through the employment of a prosthetic screw, which is also presented in a sterile state. The upper part of the abutment has a hexagonal socket to accomodate a tool for: - Implant and abutment extraction from the container. - Implant transport from the container to the insertion point. MICRODENT EKTOS CONICAL (STRAIGHT) WITH FLAP A retention screw is provided in the container with the abutment. Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended. The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment. While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis. 6
7 MICRODENT EKTOS CONICAL (STRAIGHT) WITHOUT FLAP A retention screw is provided in the container with the abutment. Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended. The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment. While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis. MICRODENT EKTOS IMMEDIATE LOADING CONICAL (STRAIGHT) A retention screw is provided in the container with the abutment. Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended. The abutment cut cannot be larger than 4.5 mm measured from the upper part of the abutment. While the abutment width must not be modified, its height can be customized. A minimum length of 4.50 mm is required in order to cement the prosthesis. MICRODENT EKTOS ANGLED A retention screw is provided in the container with the abutment. Do not to exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended. The abutment cannot be modified. Angled abutments are not recommended for the posterior region of the mouth. MICRODENT EKTOS MINI CAPITEL Use the UTSNLEC / UTSNLEC51 keys to screw the abutment and the implant together. Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended. MICRODENT EKTOS ANGLED MINI CAPITEL The UTSNATR18 retention screw and the PACN carrier are provided in the container with the angled Mini Capitel abutment. Use the PACN carrier to fix angled Mini Capitel abutment to its desired position. Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Through laboratory trials, a screwed torque of 10 / 15 Ncm was found to be recommended. MICRODENT EKTOS OSSCILIA RETENTION The use of the hex screwdriver is required to join the product and the implant together. Do not exceed a torque of 30 Ncm for the final fixation of the abutment. Do not exceed a disparallelism of 17º between implants. The exchange of retainers is facilitated through the use of the MC220PB screwdriver. The retainers are identified by color. The different colors denote different retentive strengths. - Black retainer = soft retention strength 2Kg. For use in laboratory trials. - White retainer = middle retention strength 3Kg. To keep stable for a long period of time. - Red retainer = strong retention strength 4Kg. Only to be used in special cases where an extreme fixation is required. 7
8 IMPRESSION TAKING CLOSED TRAY IMPRESSION TAKING WITH MULTIFUNCTION A multifunction abutment can be used for taking impressions with a closed tray. After testing the fitting, set the material for impressions in the tray (silicone or polyester) and take the impression. Unscrew the closed tray screw using the MH120 screwdriver and place the implant copies into the impression in the same position as they are in the mouth. Cast the model with type IV clay (ISO 6873) and use silicone if needed. Necessary material HEX. MULTIFUNCTION TRANSFER BALL SCREW IMPLANT ANALOG ANALOG (MH120) CLOSED TRAY OPEN TRAY IMPRESSION TAKING Remove the healing abutment with the MH120 screwdriver and clean the implant emergence area. Set the transfer on the base of the implant ensuring that it is perfectly settled. Screw it to the implant with a long or short open tray screw using the MH120 screwdriver. Place the drilled transfer area tray (circular or hexagonal) to test the fit. Make sure the screw heads stand out 1 mm and ensure they are easy to reach after taking the impression. After testing the fitting, set the material for impressions in the tray (silicone or polyester) and take the impression. Unscrew the emerging screws when removing the impression using the MH120 screwdriver. Remove the tray and fix the implant copies very carefully into the impression, then cast the model with type IV clay (ISO 6873). Silicone is recommended when simulating soft tissues. Long transfers (14mm H) will be used when the adjacent teeth have high crown length and when the patient s mouth opening is broad. Short transfers (10mm H) will be used for short crown lengths and small mouth openings. Necessary material HEX. SHORT TRANSFER HEX. LONG TRANSFER OPEN TRAY CIRCULAR SHORT TRANSFER CIRCULAR LONG TRANSFER OPEN TRAY TRANSFER LONG SCREW OPEN TRAY TRANSFER SHORT SCREW IMPLANT ANALOG (MH120) 8
9 CLOSED TRAY IMPRESSION TAKING Remove the healing abutment with the MH120 screwdriver and clean the implant emergence area. Set the transfer on the base of the implant ensuring that it is perfectly settled. Screw it to the implant with a closed tray screw using the MH120 screwdriver and cover the screw with the plastic cap to avoid any silicone from entering. After testing the fitting, set the material for impressions in the tray (silicone or polyester) and take the impression. Unscrew the closed tray screw using the MH120 screwdriver and place the implant copies into the impression in the same position as they are in the mouth. Cast the model with type IV clay (ISO 6873) and use silicone if needed. Necessary material HEXAGONAL TRANSFER TRANSFER SCREW PROTECTIVE CAP IMPLANT ANALOG (MH120) OPEN TRAY CIRCULAR TRANSFER TRANSFER BALL SCREW PROVISIONAL Necessary material Multifunction abutment and/or Immediate loading abutment Multifunction abutments can be used for both single and multiple prosthesis. Use Immediate loading hexagonal abutments for single restorations (they can also be used for multiple prosthesis) and Immediate loading circular abutments for multiple prosthesis. HEX. MULTIFUNCTION TRANSFER BALL SCREW (DL120) MULTIFUNCTION IMMEDIATE LOADING CONICAL HEX. IMMEDIATE LOADING IMMEDIATE LOADING CONICAL CIRCULAR OPEN TRAY TRANSFER LONG SCREW RETENTION SCREW (DL120) 9
10 CEMENTED PROSTHESIS SINGLE CEMENTED PROSTHESIS: NECESSARY MATERIAL Conical abutment hexagonal with and without flap Recommended for single prosthesis. The conical abutment can be either with or without flap. In the conical abutment with flap, the prosthetic crown has to end with a shoulder joint. In the conical abutment without flap, the prosthetic crown has to end at 0 mm, in order to lean on the implant platform (like a knife cutting edge). The conical abutment with flap is recommended when there are more than 2 mm of keratineized gum, and an optimal emergency profile can be created. The conical abutment without flap is recommended when there are less than 2 mm of keratineized gum. This is a situation that can cause a difficult aesthetic situation but it is rectifiable with this kind of abutment. Angled abutment The angled abutment is recommended to compensate insertions caused by implant inclinations up to 25º. Available in three different angles (15º, 20º and 25º). To maintain the exact position of the implant connection, a hexagonal connection is used. CONICAL WITH FLAP RETENTION SCREW (DL120) CONICAL HEXAGONAL CONICAL WITHOUT FLAP RETENTION SCREW (DL120) AESTHETIC ANGLED AESTHETIC ANGLED RETENTION SCREW (DL120) Cement the prosthesis with the cement suggested for this kind of restorations 10
11 MULTIPLE CEMENTED PROSTHESIS: NECESSARY MATERIAL Conical abutment circular with and without flap Recommended for multiple prosthesis. The conical abutment can be either with flap or without flap. In the conical abutment with flap, the prosthetic crown has to end with a shoulder joint. The conical abutment with flap is recommended when there are more than 2 mm of keratineized gum, and an optimal emergency profile can be created. Angled abutment The angled abutment is recommended to compensate insertions caused by implant inclinations up to 25º. Available in three different angles (15º, 20º and 25º). CONICAL WITH FLAP RETENTION SCREW (DL120) CONICAL CIRCULAR CONICAL WITHOUT FLAP RETENTION SCREW (DL120) AESTHETIC ANGLED AESTHETIC ANGLED RETENTION SCREW (DL120) Cement the prosthesis with the cement suggested for this kind of restorations 11
12 CEMENT-SCREWED PROSTHESIS IMPRESSION TAKING: NECESSARY MATERIAL Mini Capitel abutment transfer and Mini Capitel analog Place the transfer on the Mini Capitel abutment. Proceed to take impressions with an open or closed tray. Once the impression is done, remove the transfer and drag the impression along with the carrier. Place the Mini Capitel analog in the impression. PROSTHESIS: NECESSARY MATERIAL Mini Capitel abutment Recommended for screwed multiple prosthesis. Mini Capitel abutments allow the complete prosthesis to be placed and removed even when the implants are not parallel. It is fixed on the platform of the implant, forming a single compact body without the possibility of rotational motion. It allows a compensation of up to 35º between implants (with no greater than 17.5º compensation for either of the two implants) to remedy disparallelism as well as providing a perfect adjustment and a vertical removal of the prosthesis. Available in different heights: from 1 mm to 4 mm, depending on the platform. For prosthetic restorations with either the Mini Capitel abutment or the angled Mini Capitel abutment, the same prosthetic accessories are used. The angled Mini Capitel abutment has an angle between 17º and 30º and a height of 0 mm and 1 mm. Mini Capitel abutment or angled Mini Capitel abutment Cementable abutment. Closed tray transfer Closed tray retention screw IMPRESSION TAKING MINI CAPITEL TRANSFER MINI CAPITEL Open tray transfer Open tray retention screw ANALOG (DL120) CIRCULAR MINI CAPITEL APPLICATOR MULTIPLE PROSTHESIS MINI CAPITEL MINI CAPITEL OR ANGLED MINI CAPITEL ANGLED HEX. MINI CAPITEL RETENTION SCREW CARRIER CEMENTABLE (DL120) Cementable abutment is common for both Mini Capitel and angled Mini Capitel abutments 12
13 REMOVABLE PROSTHESIS. OVERDENTURES IMPRESSION TAKING: NECESSARY MATERIAL Osscilia transfer and Osscilia analog Place the transfer on the Osscilia abutment, which is held by an elastic washer. Proceed to take impressions with an open tray. Once the impression is done, remove the tray and drag the impression along with the carrier. Place the Osscilia analog in the impression. PROSTHESIS: NECESSARY MATERIAL Osscilia abutment The retainer of the abutments for overdenture retention can be easily exchanged by a practitioner. An Osscilia abutment has a reduced prosthetic height and an emergence diameter of only 3.50 mm. The complete ensemble is formed by a metallic cap and three different types of interchangeable retainers that are housed inside the metallic cap. Through the employment of a simple key and the screw, the retainers are fixed. Different colors denote different strengths of retention. Black retainer = soft retention 2 Kg. For use in laboratory trials. White retainer = middle retention 3 Kg. To keep stable for a long period of time. Red retainer = strong retention 4 Kg. Only to be used in special cases when an extreme fixation is required. IMPRESSION TAKING OSSCILIA OVERDENTURES TRANSFER OSSCILIA TRANSFER OSSCILIA ANALOG OSSCILIA (DL120) PROSTHESIS OSSCILIA OVERDENTURES (MC220PB) OSSCILIA OSSCILIA RETENTION + METAL CAP BLACK RETAINER SOFT RETENTION STRENGTH WHITE RETAINER MIDDLE RETENTION STRENGTH RED RETAINER STRONG RETENTION STRENGTH (DL120) 13
14 LABELING CODE SYMBOLOGY S Images 1: image of primary packaging of a Microdent abutment Images 2: image of secondary packaging of a Microdent abutment IMPLANTS Unique Device Identifier (DI&PI) Device Identifier Manufacturer Implant type Do not re-use Caution, consult accompanying documents Caution: federal law restrics this device to sale by or on the order of a dental professional Endosteal diameter Reference/article number Lot/batch number Do not use if package is damaged Site for Instructions or Use (IFU) review Sterile by irradiation Expiration date Image 3: images of primary packaging (right) and secondary packaging (left) for a Microdent implant Two similar labels are included as guidance for practitioners, inside the implant package 14
15 INSTRUCTIONS FOR USE In accordance and compliance with legal requirements, all implants manufactured by Implant Microdent System have instructions for use. These instructions are available at MRI SAFETY INFORMATION Implants and abutments have not been evaluated for safety and compatibility in the MR environment. Implants and abutments have not been tested for heating, migration, or image artifact in the MR environment. The safety of implants and abutments in the MR environment is unknown. Scanning a patient who has this device may result in patient injury. SURGICAL INSTRUMENTS For a proper use and cleaning of surgical instruments, consult their instructions for use. GUARANTEE PROGRAM Implant Microdent System provides guarantees for the products it distributes. The terms and conditions of these guarantees are indicated in the Microdent Implant System Guarantee Program, consult their instructions for use: 15
16 MICRODENT EKTOS S All prosthetic abutments are made in titanium grade 5 MICRODENT EKTOS COVER SCREW Sterilized cover screw supplied in the implant package. Use of a 1.20mm hexagonal screwdriver required. Do not cement the cover screw to the implant. Do not exceed a torque of 5Ncm. EKTC35 Platform 3.50mm EKTC45 Platform 4.50mm EKTC57 Platform 5.70mm MICRODENT EKTOS RETENTION SCREW EKTRHC Screw can be used with different types of prosthesis. Use of a 1.20mm hexagonal screwdriver required. Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. MICRODENT EKTOS HEALING EKPCR3502 Ø 3.50 height 2mm EKPCR3503 Ø 3.50 height 3mm EKPCR3504 Ø 3.50 height 4mm EKPCR3505 Ø 3.50 height 5mm Healing abutment EKPCR5702 Ø 5.70 height 2mm EKPCR4502 Ø 4.50 height 2mm EKPCR4503 Ø 4.50 height 3mm EKPCR4504 Ø 4.50 height 4mm EKPCR4505 Ø 4.50 height 5mm This abutment is intended for further use of Osscilia abutments and conical abutments without flap. Abutment supplied in sterile state. Use of a 1.20mm hexagonal screwdriver required. Do not cement the cover screw to the implant. Do not exceed a torque of 25Ncm. 16
17 EKPR3502 Ø 3,50 height 2mm EKPR3503 Ø 3,50 height 3mm EKPR3504 Ø 3.50 height 4mm EKPR3505 Ø 3.50 height 5mm Aesthetic Healing abutment EKPR5702 Ø 5.70 height 2mm EKPR4502 Ø 4.50 height 2mm EKPR4503 Ø 4.50 height 3mm EKPR4504 Ø 4.50 height 4mm EKPR4505 Ø 4.50 height 5mm Abutment supplied in sterile state. Use of a 1.20mm hexagonal screwdriver required. Do not cement the cover screw to the implant. Do not exceed a torque of 25Ncm. MICRODENT EKTOS MULTIFUNCTION (STRAIGHT) Multifunction abutment EKPMF35 Ø 3.50 height 0mm EKPMF45 Ø 4.50 height 0mm Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15 Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. Abutment can be cut, accepting minor changes in its design. 17
18 MICRODENT EKTOS CONICAL (STRAIGHT) WITH FLAP Hexagonal EKPCCP3501H Ø 3.50 height 1mm EKPCCP3503H Ø 3.50 height 3mm EKPCCP3505H Ø 3.50 height 5mm Conical abutment hexagonal with flap EKPCCP5701H Ø 5.70 height 1mm EKPCCP4501H Ø 4.50 height 1mm EKPCCP4503H Ø 4.50 height 3mm EKPCCP4505H Ø 4.50 height 5mm Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. Abutment can be cut, accepting minor changes in its design. Circular EKPCCP3501R Ø 3.50 height 1mm EKPCCP3503R Ø 3.50 height 3mm EKPCCP3505R Ø 3.50 height 5mm Conical abutment circular with flap EKPCCP5701R Ø 5.70 height 1mm EKPCCP4501R Ø 4.50 height 1mm EKPCCP4503R Ø 4.50 height 3mm EKPCCP4505R Ø 4.50 height 5mm Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. Abutment can be cut, accepting minor changes in its design. 18
19 MICRODENT EKTOS CONICAL (STRAIGHT) WITHOUT FLAP Hexagonal EKPCSP3500H Ø 3.50 height 0mm EKPCSP3501H Ø 3.50 height 1mm EKPCSP3502H Ø 3.50 height 2mm EKPCSP3503H Ø 3.50 height 3mm EKPCSP3504H Ø 3.50 height 4mm EKPCSP3505H Ø 3.50 height 5mm Conical abutment hexagonal without flap EKPCSP4500H Ø 4.50 height 0mm EKPCSP4501H Ø 4.50 height 1mm EKPCSP4502H Ø 4.50 height 2mm EKPCSP4503H Ø 4.50 height 3mm EKPCSP4504H Ø 4.50 height 4mm EKPCSP4505H Ø 4.50 height 5mm EKPCSP5700H Ø 5.70 height 0mm EKPCSP5701H Ø 5.70 height 1mm The screw can be used with all the different types of abutments. Use of a 1.20mm hexagonal screwdriver required. Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. 19
20 Circular EKPCSP3500R Ø 3.50 height 0mm EKPCSP3501R Ø 3.50 height 1mm EKPCSP3502R Ø 3.50 height 2mm EKPCSP3503R Ø 3.50 height 3mm EKPCSP3504R Ø 3.50 height 4mm EKPCSP3505R Ø 3.50 height 5mm Conical abutment circular without flap EKPCSP4500R Ø 4.50 height 0mm EKPCSP4501R Ø 4.50 height 1mm EKPCSP4502R Ø 4.50 height 2mm EKPCSP4503R Ø 4.50 height 3mm EKPCSP4504R Ø 4.50 height 4mm EKPCSP4505R Ø 4.50 height 5mm EKPCSP5700R Ø 5.70 height 0mm EKPCSP5701R Ø 5.70 height 1mm Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. Abutment can be cut, accepting minor changes in its design. MICRODENT EKTOS IMMEDIATE LOADING CONICAL (STRAIGHT) HEXAGONAL CIRCULAR Immediate loading conical abutment EKPCI3500H Ø 3.50 height 0mm EKPCI4500H Ø 4.50 height 0mm EKPCI5700H Ø 5.70 height0mm EKPCI3500R Ø 3.50 height 0mm EKPCI4500R Ø 4.50 height 0mm EKPCI5700R Ø 5.70 height 0mm Abutment supplied with a retention screw. Use the EKTUCI screw for impression taking when using immediate loading abutments. Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. Abutment can be cut, accepting minor changes in its design. 20
21 MICRODENT EKTOS ANGLED EKPAE3515H Ø 3.50 / 15º EKPAE3520H Ø 3.50 / 20º EKPAE3525H Ø 3.50 / 25º Hexagonal Aesthetic Angled abutment (height 0mm) EKPAE5715H Ø 5.70 / 15º EKPAE5720H Ø 5.70 / 20º EKPAE5725H Ø 5.70 / 25º EKPAE4515H Ø 4.50 / 15º EKPAE4520H Ø 4.50 / 20º EKPAE4525H Ø 4.50 / 25º Abutment supplied with the corresponding screw. Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. MICRODENT EKTOS MINI CAPITEL EKCAPN3501R Ø 3.50 height 1mm EKCAPN3502R Ø 3.50 height 2mm EKCAPN3503R Ø 3.50 height 3mm EKCAPN3504R Ø 3.50 height 4mm Circular Mini Capitel abutment EKCAPN5701R Ø 5.70 height 1mm EKCAPN5702R Ø 5.70 height 2mm EKCAPN4501R Ø 4.50 height 1mm EKCAPN4502R Ø 4.50 height 2mm EKCAPN4503R Ø 4.50 height 3mm EKCAPN4504R Ø 4.50 height 4mm Screw in the abutment using the UTSNLEC key. Do not exceed a torque of 30 Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. 21
22 MICRODENT EKTOS ANGLED MINI CAPITEL ANGLED 17º ANGLED 30º EKCAPNA35170H Ø 3.50 height 0mm EKCAPNA35171H Ø 3.50 height 1mm EKCAPNA35300H Ø 3.50 height 0mm EKCAPNA35301H Ø 3.50 height 1mm Hexagonal angled Mini Capitel abutment EKCAPNA45170H Ø 4.50 height 0mm EKCAPNA45171H Ø 4.50 height 1mm EKCAPNA45300H Ø 4.50 height 0mm EKCAPNA45301H Ø 4.50 height 1mm Abutment supplied with UTSNATR18 retention screw and PACN positioner. Use the PACN positioner to facilitate the desired fixation of the abutment. Do not exceed a torque of 30Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. Do not exceed a torque of 15Ncm for prosthetic retention screws. 22
23 Microdent Mini Capitel and Angled Mini Capitel abutment components MICRODENT EKTOS MINI CAPITEL FIXING KEY UTSNLEC Standard platform Material: Stainless steel UTSNLEC1 Wide platform Material: Stainless steel MICRODENT EKTOS MINI CAPITEL AND ANGLED MINI CAPITEL CEMENTABLE UTSNPC4X Standard platform Material: Titanium grade 5 UTSNPC51 Wide platform Material: Titanium grade 5 Mini Capitel cementable copings cannot be milled. MICRODENT EKTOS MINI CAPITEL AND ANGLED MINI CAPITEL PROTECTIVE CAP MICRODENT EKTOS MINI CAPITEL AND ANGLED MINI CAPITEL PROSTHETIC RETENTION SCREW UTSNCP4X Standard platform Material: Titanium grade 5 UTSNCP51 Wide platform Material: Titanium grade 5 UTSNTR Standard platform Material: Titanium grade 5 + DLC UTSNTR1 Wide platform Material: Titanium grade 5 + DLC Do not exceed a torque of 15Ncm for prosthetic retention screws. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. PACN Angled Mini Capitel abutment carrier Material: Stainless steel UTSNATR18 Angled Mini Capitel retention screw Material: Titanium grade 5 + DLC These two components are supplied together in the same set with the angled Mini Capitel abutment. Use of a 1.20mm hexagonal screwdriver required. Do not exceed a torque of 30 Ncm for the fixation of the abutment. For laboratory tests, the torque recommended is 10/15Ncm. It is recommended to not use the same screws as in the laboratory tests to fix the abutment but to use new ones. 23
24 MICRODENT EKTOS OSSCILIA RETENTION EKEOSS3500 Ø 3.50 height 0mm EKEOSS3501 Ø 3.50 height 1mm EKEOSS3502 Ø 3.50 height 2mm EKEOSS3503 Ø 3.50 height 3mm EKEOSS3504 Ø 3.50 height 4mm EKEOSS4500 Ø 4.50 height 0mm EKEOSS4501 Ø 4.50 height 1mm EKEOSS4502 Ø 4.50 height 2mm EKEOSS4503 Ø 4.50 height 3mm EKEOSS4504 Ø 4.50 height 4mm Osscilia retention abutment EKEOSS5700 Ø 5.70 height 0mm EKEOSS5701 Ø 5.70 height 1mm Use of a 1.20mm hexagonal screwdriver required to fix the implant. Do not exceed a torque of 30Ncm. Do not exceed a maximum non-parallelization of 15 from the vertical. CSUTGOSS Metal cap with soft, middle and strong retainers Material: Titanium grade 5 + POM MC220PB Microdent Osscilia retainer screwdriver Material: Stainless steel Metal cap with soft, middle or strong Osscilia retainer Available with three different retention levels, identified by a colored plastic cap: - Black plastic cap: supplied with an embedded metal sheath, it has a soft retention for clinical or laboratory tests. - White plastic cap: it has a medium retention very appropriate to keep stable during a long time period. - Red plastic cap: used in specific cases where extreme fixation is required. The key for the Osscilia retainers is a MC220PB. 24
25
MICRODENT EXTERNAL CONNECTION PRODUCTS GUIDE EXTERNAL CONNECTION IMPLANTS IMPLANTOLOGY SYSTEMS. Product presentation. Digital information
Product presentation Digital information IMPLANTOLOGY SYSTEMS EXTERNAL CONNECTION PRODUCTS GUIDE www.microdentsystem.com Implant catalogues SYSTEM UNIVERSAL Implantes de conexión externa Other catalogues
More informationLegacy Prosthetic Catalog
Legacy Prosthetic Catalog Straight Snap-On Straight Contoured Angled Contoured Ball Attachment Gold/Plastic Castable Locator Attachment Plastic Temporary Screw Receiving Plastic Non-Engaging Castable 15
More informationNARROW DIAMETER implant
ND NARROW DIAMETER implant TABLE OF CONTENTS ND - NARROW DIAMETER implant Implant characteristics page 04 Dental implant page 05 Open Tray Impression Transfer page 06 Titanium Abutments page 07 O-Ball
More informationINSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)
INSTRUCTIONS FOR THE DENTIST synocta impression procedure, Screw-retained and Snap-on Screw-retained (Open tray) Snap-on (Closed tray) click 1. Attach synocta Impression caps to implants. Hand-tighten
More informationProsthodontic Procedure
Prosthodontic Procedure TSH BNT Regeneration Implant Systems CAD-CAM Digital Solutions Services Important: before using Phibo The innovative and patented design of the Phibo implant systems incorporates
More informationLegacy TM. System Catalog. Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4
Legacy TM System Catalog Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4 Table of Contents Page # Design, Surface & Dimensions 1-5 6-13 Legacy TM 1, Legacy TM 2, Legacy TM 3 & Legacy TM 4 s Labeling &
More informationMiNi Overdenture Fixture
MiNi Overdenture Option MiNi Overdenture Fixture 1. Product Concept 1. Fast osseointegration for thanks to our SLA surface treatment. 2. Excellent for maxillary lateral incisor and mandible anterior. 3.
More informationSimpleLine II Surgical / Prosthesis Manual
SimpleLine II Surgical / Prosthesis Manual SimpleLine II SURGICAL MANUAL Surgical Drill Sequence 04 Fixture Installation 05 Fixture Connection 06 Surgical Kit Maintenance 08 Warnings 09 04 SimpleLine ll
More informationSwissPlant Prosthetic Catalog. SwissPlant
SwissPlant Prosthetic Catalog Contoured Snap-On Angled Contoured Ball Attachment Gold/Plastic Castable Locator Attachment Plastic Temporary Screw Receiving Plastic Non-Engaging Castable Narrow Titanium
More informationThe LOCATOR concept. Simplicity and versatility for prosthesis fixation
The concept Simplicity and versatility for prosthesis fixation The concept Experience the freedom in prosthesis fixation Simple and secure fixation of implant-supported prostheses is essential for successful
More informationProsthodontic Procedure
Prosthodontic Procedure TSA TSA Advance Regeneration Implant Systems CAD-CAM Digital Solutions Services IMPORTANT: BEFORE USING Phibo The innovative and patented design of the Phibo implant systems incorporates
More informationAbutment level impression Ⅰ. Combi abutment/dual abutment Multi units
Pr osthetic par t Abutment level impression Ⅰ Combi abutment/dual abutment Multi units Prosthetic part Remove Cover screw Prosthetic part Remove Healing abutment Prosthetic part Select suitable Combi abutment,
More informationOT EQUATOR CASTABLE Single Attachment for Overdentures
OT EQUATOR CASTABLE Single Attachment for Overdentures pick-up impression OT EQUATOR PROFILE CASTABLE MALE ATTACHMENT individual tray RETENTIVE CAPS OT EQUATOR HOUSING VIOLET CAP RIGID RETENTION (2.7Kg)
More informationFor the oral rehabilitation
For the oral rehabilitation Contents For superstructures Chapter 1 Overview of prosthetic modes 1. Prosthetic modes of the PLATON system 2. Factors involved in prosthetic design Chapter 2 Cement-retained
More informationStraight Octagon Abutment for Tissue Level Implant
Cover screw in place The presentation that follows lists only one combination of parts. Obviously the clinical situation may call for substitution of another part on this slide Prosthetic instruments needed
More informationINTRODUCTION. Why Choose Cortex Prosthetics?
Prosthetic Manual 4 INDEX Introduction 6-14 Impression Techniques 15-29 Abutments Selection Handling 30-33 Temporary Restorations 34-38 Screw Reiained Restorations 39-52 Removable Restorations 53-63 5
More informationIMPRESSION PROCEDURES TRAINING MANUAL
IMPRESSION PROCEDURES TRAINING MANUAL 01 01 A.B. DENTAL A.B. Dental is proud to present this impression taking procedure protocol. This manual explains, step by step, the procedure while using A.B. Dental
More informationMulti-Unit Abutment Guide
Multi-Unit Abutment Guide SpiralTech TM Screw-Retained & Multi-Unit Restorations Our multi-unit abutment system is designed for restoration of both partially or fully edentulous arch cases Straight Multi
More informationIQ IMPLANTS Smart Choice PRODUCT C ATA L O G
IQ IMPLANTS Smart Choice PRODUCT C ATA L O G www.iqimplants.com info@iqimplants.com 2 TABLE OF CONTENTS GENERAL Company Profile 3 IMPLANTS 5 PROSTHETICS 13 TOOLS 27 3 COMPANY PROFILE IQ Implants Ltd. reflects
More information. Simplification. High Performance. Safety and Longevity. The fundamental goal is to restore the quality of life of patients.
Catalog 4 P-I product line was developed by te Osseointegration pioneer, Professor Per-Ingvar Brånemark, jointly wit experienced scientists in world recognized entities to meet modern implant dentistry
More informationSCREW-RETAINED RESTORATION LINE. THE MULTI UNIT ABUTMENT SYSTEM ON STRAIGHT and tilted IMPLANTS
SCREW-RETAINED RESTORATION LINE THE MULTI UNIT ABUTMENT SYSTEM ON STRAIGHT and tilted IMPLANTS 2 SCREW-RETAINED RESTORATION LINE SCREW-RETAINED RESTORATION LINE 3 PROFESSIONAL SYSTEM FOR SUPERIOR ESTHETICS
More informationPRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.
PRODUCT CATALOG Since 1985» Simple. Predictable. Profitable. 2014 IMPLANTS HEALING PLUG INSERTERS COLLAGEN PRODUCTS 3.0mm Well Integra-CP Part No. DIAMETER LENGTH Price 345-306 4.5mm mm $280.00 345-308
More informationNEW NEW. An Extended Solution for Narrow Ridges
NEW mm NEW An Extended Solution for Narrow Ridges NICE System: An Extended Solution for Narrow Ridges Quality Alpha-Bio Tec presents an advanced new NARROW implant solution for narrow alveolar ridges and
More information4766 Research Dr. San Antonio, TX insightdentalsystems.com
OVERVIEW OF THE INSIGHT DENTAL IMPLANT DELIVERY SYSTEM The IDS system comes in a unit dose implant system where its advantage provides sterile instrumentation in one single-use kit. It is organized to
More informationProsthodontic Procedure
Prosthodontic Procedure Aurea Regeneration Implant Systems CAD-CAM Digital Solutions Services AUREA IMPLANT SYSTEM PROSTHODONTIC PROCEDURE IMPORTANT BEFORE USING AUREA IMPLANT SYSTEM The innovative and
More informationGMI. MONOLITH implant system. Surgical procedures guide
GMI MONOLITH implant system Surgical procedures guide ABOUT THIS MANUAL This surgical procedures guide or surgical manual for the GMI MONOLITH implant system is designed solely to provide instructions
More informationRDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED
RDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED Introducing the new CIT Implant C ONFIDENCE I NSPIRING T ECHNOLOGY see more page.10 RDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED TABLE OF CONTENTS
More informationBiomimetic PEARL. Product catalogue
Biomimetic PEARL Product catalogue PEARL is the AVINENT system of mini implants, an innovative product with unique features that aims to provide a quality alternative to what is available today as regards
More informationN E W S M I L E S E V E R Y D AY
C ATA LO G 2 0 6 N E W S M I L E S E V E R Y D AY Neodent provides you with a complete range of products and services that are designed and produced by a team of professionals who truly love what they
More informationStep-by-Step Cemented Bridge Using Using CPK Abutments. Internal Hex. Implant System
4. 6. Step-by-Step Cemented Bridge Using Using CPK Abutments Internal Hex. Implant System MIS Corporation. All rights reserved. Published by MIS, which reserves the right to ameliorate the products described
More informationthe perfect fusion Catalogue
the perfect fusion Catalogue Valladolid, June 2014 Dear Doctors, We are pleased to introduce our new MG In-Hex Catalogue 2014. Castilla y León Young Businessman of the Year Award. Valladolid 2003 Established
More informationNEW. An Extended Solution. for Narrow Ridges
mm NEW An Extended Solution for Narrow Ridges NICE System: An Extended Solution for Narrow Ridges Quality Alpha-Bio Tec presents an advanced new NARROW implant solution for narrow ridges and tight spaces.
More informationGMI FRONTIER implant system. Surgical procedures guide
GMI implant system Surgical procedures guide ABOUT THIS MANUAL This surgical procedures guide or surgical manual for the GMI implant system is designed solely to provide instructions for using GMI products,
More informationUFII : Unique Fixture, 2 nd Generation. UFII Design Characteristics
UFII : Unique Fixture, 2 nd Generation UFII Design Characteristics 1. Hybrid SLA Surface Treatment 2. Tapered-Straight Combined Shape 3. Hex Internal Connection 4. Dual Morse Tapered Connection (11 Morse)
More informationProduct Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER
Product Catalogue 1 Product Chart Follow the lines to see which products that fits both diameters and which that are special. In true OSPOL philosophy, most of the instruments and abutments fits both diameters.
More informationUser Manual Complete Prosthetic Kit (CPK)
User Manual Complete Prosthetic Kit (CPK) The Complete Prosthetic Kit is designed to enable easy impression and transfer technique and to prevent the need to remove and to re-tighten the abutments. Advantages
More informationStraumann Screw-retained Prosthetics
Straumann Screw-retained Prosthetics Straumann Screw-retained Abutments Straumann Screw-retained abutments Indication and product features Abutments for fixed screw-retained restorations; for multi-unit
More informationGmbH DENTAL IMPLANT SYSTEMS PRODUCT CATALOG
I M P L A N T GmbH DENTAL IMPLANT SYSTEMS PRODUCT CATALOG 2 ABOUT US GLOBAL IMPLANT GmbH is a Dental leading international company specializing in the development, manufacturing and marketing of Dental
More informationAstra Tech Implant System. Manual and product catalog OsseoSpeed TX Profile
Astra Tech Implant System Manual and product catalog OsseoSpeed TX Profile Adapting with nature OsseoSpeed TX Profile anatomically designed implants for sloped ridges Imagine being able to achieve 360
More informationSwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD
SwishPlant System Catalog ------------ 4.1mmD ------------ 3.7mmD ------------ 3.3mmD SwishPlant 6.5mmD ------------ 6.5mmD ------------ 5.7mmD Table of Contents SwishPlant Fixture Mount Packaging Page
More informationSuperLine & Implantium Surgical / Prosthesis Manual
SuperLine & Implantium Surgical / Prosthesis Manual SuperLine & Implantium SURGICAL MANUAL Surgical Drill Sequence I 04 Surgical Drill Sequence II 06 Drilling Depth Guide 08 Fixture Connection 10 Installation
More informationQuick start Prosthetics
EN Quick start Prosthetics Easy and effective YELLOW PROSTHETIC PLATFORM QN CEMENTED RESTORATIONS ESTHETIC AUTMENTS OPEN TRAY POST IMPLANT ANALOG Indexed components with internal conical connection. 0.7
More informationNEW. An Extended Solution. for Narrow Ridges
mm NEW An Extended Solution for Narrow Ridges NICE System: An Extended Solution for Narrow Ridges Quality Alpha-Bio Tec presents an advanced new NARROW implant solution. An addition to the existing range
More informationELSNER SYSTEM OVERVIEW Revolutionary solutions for your implant prosthetic problems
ELSNER SYSTEM OVERVIEW Revolutionary solutions for your implant prosthetic problems E L S N E R S Y S T E M LT D. www.elsnersystem.co.uk Elsner System Ltd. info@elsnersystem.com CONTENTS,CERTIFICATIONS
More informationS i m p l i c I t y, c o m f o r t, a e s t h e t i c s. axiom. The new dimension
S i m p l i c I t y, c o m f o r t, a e s t h e t i c s axiom The new dimension 2 Implants by anthogyr axiom, t h e n e w g e n e r a t i o n i m p l a n t axiom characteristics represent the perfect synthesis
More informationBiomimetic Product catalogue
Biomimetic Product catalogue 20 Pol. Industrial Santa Anna I Apartado 20 08251 Santpedor (Barcelona) España T. (+34) 902 38 38 48 F. (+34) 93 827 38 73 www.avinent.com avinent@avinent.com 1 CORAL is the
More informationIMPLANTS. Pearls. Your Precious Pearls. Made in Germany
M2 IMPLANTS Your Precious Pearls Made in Germany Pearls collection Pearls collection CORPORATE PROFILE Introduction: As per our long experience in the dental industry, Zakton LLC, headquartered in the
More informationThe intelligent system.
The intelligent system. Contents This is isy The intelligent system 5 Cost efficient implant sets 7 Total flexibility 9 Purposeful simplicity 11 The digital future 13 Quality without compromise 15 isy
More informationCATALOG. Since 1985» Simple. Predictable. Profitable.
CATALOG Since 1985» Simple. Predictable. Profitable. 2018 19 IMPLANTS SYNTHOGRAFT TEMPORARY ABUTMENTS (Ti) 3.0mm Well Integra-CP PART NO. DIAMETER LENGTH PRICE 345-305 4.5mm 5.0mm $290.00 345-306 4.5mm
More informationINTERNAL HEX ( ps) PLATFORM SHIFT PRESERVATION OF BONE NEVER LOOKED BETTER
INTERNAL HEX ( ps) PRESERVATION OF BONE NEVER LOOKED BETTER infinite opportunities in implantology For almost 50 years ACE Surgical has been dedicated to dental surgical advancements. We continue to develop
More informationSuperLine & Implantium Surgical / Prosthesis Manual
SuperLine & Implantium Surgical / Prosthesis Manual SuperLine & Implantium SURGICAL MANUAL Surgical Drill Sequence 04 Drilling Depth Guide 06 Fixture Connection 08 Installation Procedure & Warnings 09
More informationNARROW DIAMETER implant
N NARROW IAMETER implant N Precision dental solutions C-Tech Implant is a dynamic company with aggressive growth, producing components and product lines primarily for dental implantology. International
More informationAnkylos. Acuris conometric concept. Manual and product catalog
Ankylos Acuris conometric concept Manual and product catalog Ankylos Implanting TissueCare The true value of an implant system becomes apparent with time. For over 25 years, the Ankylos implant system
More informationUS Implant System 2013 PROSTHETIC PROCEDURE
US Implant System 2013 PROSTHETIC PROCEDURE Contents TS Implant System Cement retained restoration 06 Cement retained bridges with the Cement abutment system 18 Cement retained crown with the Angled abutment
More informationMulti-unit abutment open tray technique using the direct pick-up coping
Multi-unit abutment open tray technique using the direct pick-up coping impression techniques Multi-unit abutment open tray technique using the direct pick-up coping Use this technique to make an impression
More informationBiomimetic PEARL. Product catalogue
Biomimetic PEARL Product catalogue PEARL is the AVINENT system of mini implants, an innovative product with unique features that aims to provide a quality alternative to what is available today as regards
More informationNARROW DIAMETER implant
NARROW IAMETER implant Impianto NARROW IAMETER Implant characteristics pag 04 ental Implants pag 06 Titanium healing abutments pag 06 Open tray impression transfer pag 07 Closed tray impression transfer
More informationGUIDED SURGERY TECHNIQUE
GUIDED SURGERY TECHNIQUE INDEX WORKFLOW...4 OUR SOLUTIONS...5 PLANNING PROTOCOL - PARTIAL EDENTULISM...6 - TOTAL EDENTULISM...9 SOFTWARE FEATURES...12 SURGICAL COMPONENTS FOR GUIDED IMPLANTOLOGY...14
More informationOsteotome inserts kit, angled. Impression tube (open tray) Selection abutment kit / Selection measurement post. Bar base PMMA & Finisher
Osteotome inserts kit, angled Impression tube (open tray) Locator system Selection abutment kit / Selection measurement post Bar base PMMA & Finisher Titaniumbase for CAD/CAM, long Clue support Locator
More informationisy indications and techniques
This is isy 3 The isy Implant System demonstrates its unique talents in numerous indications. Its intelligence allows the clinician to focus on what is most common in their everyday implant practice. isy
More informationRATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG A company of the KLINGEL GROUP
RATCHETS RATCHET ACCESSORIES DENTAL PRODUCTS PRODUCT CATALOG 0 A company of the KLINGEL GROUP Contents Universal ratchet without torque function General information All ratchets are available with different
More informationRePlant System Prosthetic Catalog
RePlant System Prosthetic Catalog Healing Collars, Transfers, Analogs & Alignment Tools Healing Collars Components include Dual-Grip feature for use with 1.25mmD Hex Tool or Nobel Unigrip ScrewDriver Width
More informationVery small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants
Very small abutment head easy and secure handling Ankylos The SmartFix concept Prosthetic solution on angled implants Stable prosthetic fit The area supporting the prosthesis is extended distally by the
More informationNEODENT GUIDED SURGERY
NEODENT GUIDED SURGERY MANUAL Grand Morse Connection Helix Implant GRAND POSSIBILITIES WITH A LIMITLESS SOLUTION. GRAND MORSE NEODENT GUIDED SURGERY. 4 5 6 CONTENTS 1. CLINICAL STEP BY STEP OF GRAND
More informationProduct Catalog. Since 1985» Simple. Predictable. Profitable.
Product Catalog Since 1985» Simple. Predictable. Profitable. 2011 IMPLANTS 3.0mm Well Integra-CP Part No. DIAMETER LENGTH 345-306 4.5mm 6.0mm 345-308 4.5mm 8.0mm 345-311 4.5mm 11.0mm 350-305 5.0mm 5.0mm
More informationSIMPLE INSERTION, NATURAL STABILITY. Self-cutting capacity in both directions Makes it possible to achieve high primary stability with low torque
JD EVOLUTION PLUS+ SIMPLE INSERTION, NATURAL STABILITY. FEATURES ADVANTAGES Internal hex connection with lead-in bevel, 100% compatible with Zimmer Screw-Vent The Connection is universally recognized by
More informationMulti-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants
Multi-Unit Abutment System SIC Safe on Four Optimum use of available bone by angled placement of implants Multi-Unit Abutment System SIC Safe on Four Safe on Four The SIC Safe on Four system is a further
More informationInterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free
InterActive System Prosthetic Catalog simplycrown & bridge SMART PACK InterActive All-in-1 Packaging simplyinteractive Mount-Free CONICAL Cover Screws, Healing Collars & Transfers Replacement Surgical
More informationSS Implant System 2013 PROSTHETIC PROCEDURE
SS Implant System 2013 PROSTHETIC PROCEDURE Contents TS Implant System Cement retained restoration 06 Cement-retained bridges with the Solid abutment system (non-modified abutment) 16 Cement-retained bridges
More informationAnchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282
tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282 266 . innovative comprehensive efficient. Dentaurum Online Shop shop.dentaurum.com
More informationGuided surgery manual
Including product catalog Guided surgery manual SIMPLANT computer guided implant treatment with the ASTRA TECH Implant System EV CONTENTS Introduction Drilling protocol and bone classification 4 Implant
More informationDental Implant Catalog All Rights Reserved
Dental Implant Catalog 2017 Dental Implant Catalog 2017 2 All Rights Reserved 3 About Contents Internal Hexagon Connection 6 Implantology made simple Medical Systems and Devices International Ltd. is a
More informationLow Profile Neuro Plating System. Surgical Technique
Low Profile Neuro Plating System Surgical Technique TABLE OF CONTENTS INTRODUCTION Low Profile Neuro Plating System 2 SURGICAL TECHNIQUE Technique 5 PRODUCT INFORMATION Low Profile Neuro Plates 10 Low
More informationPart 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants
Select Part 2 Internal Tri-Channel Connection Replace Select NobelSpeedy Replace NobelReplace and compatible implants listed below Select Part 2 contains only the Tri-Channel Internal Connection compatible
More informationInstructions for Use DENTAL IMPLANTS
HAHN TAPERED IMPLANT SYSTEM Instructions for Use English General Information IMPORTANT INFORMATION PLEASE READ Caution: U.S. federal law restricts this device to sale by, or on the order of, a licensed
More informationQZ-Implant TRINON. Bone level implant with hexagonal internal cone connection
QZ-Implant Information Components are updated periodically, check with your local Trinon partner on current models Please follow Instructions for Use for individual components Images are not to scale see
More informationBridging the Gap Between Original and Multi-Platform Systems.
Product Information Straumann CARES Screw-Retained Bars & Bridges Bridging the Gap Between Original and Multi-Platform Systems. CARES SRBB solutions are compatible with the following implant systems: Neodent
More informationRestoring Straumann implants. with Locator abutments.
Restoring Straumann implants with Locator abutments. 1 1 Straumann is the industrial partner of the ITI (International Team for Implantology) in the areas of research, development, and education. Contents.
More informationType 1. Type 2. Straumann Bone Level. The L-Series abutments are compatible with» L-SERIES «
The L-Series abutments are compatible with L-SERIES «Bone Level DETAILED VIEW Exact view of the direction of the angulation (indexing) of all angled abutments. Type 1 angled over flat Type 2 angled over
More informationMulti-unit abutment closed tray technique using the indirect transfer coping
Multi-unit abutment closed tray technique using the indirect transfer coping impression techniques Multi-unit abutment closed tray technique using the indirect transfer coping Use this technique to make
More informationBONE LEVEL ABUTMENTS. on4. multi-unit
BONE LEVEL 2016 on4 multi-unit STANDARD CONNECTION STANDARD connection means that connection between implant and the abutment will be established on the platform of the implant instead of conical switching.
More informationFor technical assistance: Tel Working time: 8.30 am pm
I For technical assistance: Tel. +39 059 392827 Working time: 8.30 am - 5.30 pm Index JD Digital solutions for Intraoral Scanning JD Implant Libraries JD Guided Surgery Kit JD Surgical Guide and 3D Model
More information» For multi-unit restorations -
» For multi-unit restorations - conventional or digital «Multi-Unit Abutments 2 The Multi-unit product range is being contiunally expanded to include other abutment series. Available for a large number
More informationNEW. The SmartFix Concept Prosthetic solution on tilted implants. SmartFix
NEW The SmartFix Concept Prosthetic solution on tilted implants SmartFix The SmartFix Concept Prosthetic solution on tilted implants The SmartFix Concept is an effective and time-saving technique for immediate
More information- RESTORATIVE PRODUCT CATALOG
- RESTORATIVE PRODUCT CATALOG MADE IN USA Others make Implants to sell... Tatum Surgical makes Implants to treat your Patients. Your Source for Implants To Meet Every Clinical Need Tatum... 4 Angled Post
More informationTRINON. Index. Index. Overview Page 4. Catalogue
QK-Implant Information Components are updated periodically, check with your local Trinon partner on current models Please follow Instructions for Use for individual components Images are not to scale see
More informationC O M PA N Y P R O F I L E S I N C E W E H AV E B E E N H E L P I N G D E N T I S T S T O M A K E T H E I R PAT I E N T S S M I L E
C O M PA N Y P R O F I L E SINCE 1977 W E H AV E B E E N H E L P I N G D E N T I S T S T O M A K E T H E I R PAT I E N T S S M I L E A LONG ROAD DEDICATED TO IMPLANTOLOGY With over 40 years of experience
More informationFOR PROFESSIONALS. Product Catalogue. Cochlear Vistafix 3 System A BONE ANCHORED PROSTHETIC SOLUTION
FOR PROFESSIONALS Product Catalogue Cochlear Vistafix 3 System A BONE ANCHORED PROSTHETIC SOLUTION 1 The Vistafix 3 System consists of: Cochlear Vistafix VXI300 Implant (Vistafix 3 Implant) Cochlear Vistafix
More informationOsteoconductive S.L.A. Surface. Fantastic surface, Bioseal, and Perfect achievement of CMI f ixation.
Fantastic surface, Bioseal, and Perfect achievement of CMI f ixation. Osteoconductive S.L.A. Surface No residual acid and cytotoxicity were observed in the surface examination. IS-II active Product Catalog
More informationInstructions for Use DENTAL IMPLANTS
HAHN TAPERED IMPLANT GUIDED SURGERY SYSTEM Instructions for Use English General Information IMPORTANT INFORMATION PLEASE READ Caution: U.S. federal law restricts this device to sale by, or on the order
More informationHow something small, can make such a big difference!! Your best choice in overdenture
How something small, can make such a big difference!! Your best choice in overdenture Why? Kerator has the worldʼs most powerful competitiveness in overdenture attachment system. KERATOR was chosen over
More informationPRODUCT CATALOG 2014 CONELOG IMPLANTATSYSTEM PRODUCT PRODUKTKATALOG CATALOG 2014
PRODUCT CATALOG 2014 CONELOG IMPLANTATSYSTEM PRODUCT PRODUKTKATALOG CATALOG 2014 Valid from May 2014 ADDED VALUE THROUGH COMPETENCE IN IMPLANTOLOGY A partnership with CAMLOG encompasses the exceptional
More informationI M P L A N T O L O G Y
IMPLANTOLOGY Premium Straight The cylindrical implant with 16 years of clinical success and over 60 publications. All Premium Straight implants have a smooth collar 0.80 mm high, a cylindrical shape and
More informationTreatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l
Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l Two-Piece ReActive Tri-Lobe Implants with Multi-Unit Abutments One-Piece ScrewIndirect Implants
More informationProduct Catalog July 2017
Product Catalog July 2017 1 2 Introducing the Hahn Tapered Implant System Combining decades of clinical experience with cutting-edge design, the Hahn Tapered Implant System is a contemporary dental implant
More informationHEXAGON Implant System
HEXAGON Implant System PRODUCT N 1 CATALOG 2018 2 Table of contents Implants... 4 Prosthetics Lab Components, Abutments... 5 Zest LOCATOR, R-Tx and F-Tx...6 Multi-Unit Abutments...7 Instruments...8 Zest
More informationWhere technology meets dentistry INNOVATION. at a GLANCE
Where technology meets dentistry INNOVATION at a GLANCE ABOUT PALTOP Paltop is a premium manufacturer of dental implants that strives to provide highest quality products in the dental arena. Leveraging
More informationIR (INTELLIGENT) INTERNAL ONE-STAGE SYSTEM
IR (INTELLIGENT) INTERNAL ONE-STAGE SYSTEM MESSAGE FROM THE CEO Our company, Biotem Co. Ltd, has been working to improve and enhance dental implant technology for many years in order to provide the most
More informationIMPLANTS. Y o u r P r e c i o u s P e a r l s
M2 IMPLANTS Y o u r P r e c i o u s P e a r l s Pearls 5.0 S CORPORATE PROFILE Introduction: As per our long experience in the dental industry, Zakton LLC, headquartered in the state of Colorado, USA,