Nova Implants surface treatment is carried out by one of the worlds. Implants maintains a meticulous quality control system and complies

Size: px
Start display at page:

Download "Nova Implants surface treatment is carried out by one of the worlds. Implants maintains a meticulous quality control system and complies"

Transcription

1

2 IMPLANTS MEDICAL DEVICES & DEVELOPMENT Nova Implants Medical Devices & Development Ltd. is a young, innovative, expanding high-tech production and research company. Specializing in the development of dental solutions and advanced production techniques. Nova Implants has over a decades experience in the field, and is recognized by the industry for its high quality products and constant clinical successes. Nova Implants continuously strives to design, develop and manufacture implants and prosthetics of the highest quality by implementing the latest advancement in implant science. Nova Implants market a comprehensive range of dental implants and superstructures. Nova Implants surface treatment is carried out by one of the worlds leading laboratories who have over ten years experience and have produced thousands of implants with a high level of success. Nova Implants maintains a meticulous quality control system and complies with major quality control standards. The implants, prosthetics and accompanying aids manufactured by Nova Implants, naturally integrate into the body, reduce healing time, minimize rejections, prevent complications and provide durability for years. The surface of all Nova s implants undergo a complex procedure which significantly increases the success of the osseointegration process. The Nova Implants consulting team offers all-round professional and technical support. Nova Implants continuously strives to improve its products and simplify your procedures, providing the patients with reliable long-lasting successful results. 1 All specifications in this catalog are subject to change without prior notice. All models shown are for simulation purposes.

3 About Us 1 Contents 2 RBM Dental Impants by CST Process 3-8 NOVA Implants System PSI 9-11 NOVA Implants System PCI NOVA One Stage System DV ORTHODONTIC ANCHOR SCREW HEALING CAPS Standard 19 Narrow 19 Wide 19 Premium Healing Caps 20 PROSTHETIC ABUTMENTS Standard Straight 21 Standard Straight Long 21 Standard Straight Narrow 21 Standard with Shoulder 22 Anatomic Straight 22 NEW Anatomic Straight 22 Angulated Angulated 15 Narrow 23 Anatomic Angulated Angulated Angulated 25 Narrow 24 Anatomic Angulated NEW Anatomic Angulated NEW Anatomic Angulated Angulated Angulated BALL ATTACHMENTS 27 Standard 27 Covers 27 IMPRESSION COPINGS Closed Tray 28 Open Tray 29 Abutment Screws 29 ESTHETIC ABUTMENTS 30 Components 30 Plastic Sleeve 30 Screws 30 ABUTMENT SLEEVES 31 Delrin Hex & Non Hex 31 Delrin Wide Hex & Non Hex 31 Custom Titanium Castable 31 PLASTIC ANATOMIC ABUTMENTS 32 Anatomic Angulated Anatomic Angulated ZIRCONIUM ABUTMENTS 33 Standard 33 Angulated Angulated IMPLANT ANALOGS 34 DRILLS & COUNTERSINKS 35 IMPLANT TOOLS 36 IMPLANT TOOLS 37 TOOL KIT 37 Packaging 38 Symbols 38 Opening Instructions 39 Procedures 40 User Instructions 41 2

4 RBM dental implants by CST Process Summary NOVA Implants has completed technological validation of RBM (Resorbable Blasting Media) Process, based on its CST (Comprehensive Surface Treatment) Process. From now, our customers may benefit from well known advantages of RBM implants. RBM surface is featured by extensively developed roughness and no biocompatibility obstructions, thanks to using of biocompatible Calcium Phosphate blasting media. Calcium Phosphates are easily dissolved, leaving well textured surface completely free of contaminants. Additionally, RBM does not need strong acids for removing of blasting media remains, which contributes to implants biocompatibility as well. NOVA Implants RBM surface undergoes completing surface treatment by citric acid, also compatible to live textures. NOVA Implants RBM CST Process uses an apatite born Calcium Phosphate having approximate chemical composition of Ca3(PO4) (Tri-Calcium Phosphate), blasted at automatic blasting machine allowing uniform and repeatable surface of implants. The clean- ing, washing-out and washing stages include using of Ultrasonic Baths with De-ionized Water of high purity, air drying is carried out in clean room class 10,000, while quality control at all stages of the treatment is performed including on-line SEM-EDS control and periodical XPS and optical profilometry tests. NOVA RBM implants demonstrate high surface performances, and when checked by advanced physical instruments (SEM, EDS, XPS, Optical Profilometer) are revealed to be fully identical to the surface performances of implants manufactured by the leaders in the field: 1. The surface structure (morphology) of the NOVA Implants RBM dental implants, as exposed by SEM microphotographs, is featured by highly developed surface porosity. 2. The surface roughness of the NOVA Implants RBM dental implants is well-defined and uniform. The main roughness parameter Ra has good acceptable value of 1.9microns. 3. The surface purity of the NOVA Implants RBM dental implants, as exposed by SEM microphotographs and checked by EDS-SEM instrument, is nearly absolute: no inclusions or contaminations are detected, any point of the surface is revealed to be pure Titanium alloy. 4. The surface chemical composition of the NOVA Implants RBM dental implants, as analyzed by XPS instrument, represents well acceptable values of the main elements usually found on the dental implants surface underwent blasting and blasting media cleaning. 3

5 RBM CST Process The Process Following years of experience in developing, engineering and industrial running of its alumina- blasting-double-etching CST Process, successfully operated during several years for manufacturing hundred of thousands dental implants, NOVA Implants has entered the RBM processing as well, to contribute to the world spreading of this novel process and to allow its customers to benefit from it. The RBM CST Process as presently validated is detailed in the appropriate NOVA Implants documents and consists of the following main stages of the implants treatment: Washing from machining remains, including Ultrasonic Bathes and steam cleaning. Calcium Phosphates Blasting for formation of surface morphology, using automatic blasting machine allowing uniform and repeatable blasted surface of implants. After blasting washing. Dissolution of the blasting media in diluted inorganic acid solutions not attacking Titanium. Surface conditioning through replacement of inorganic acids by citric acid. Ultimate washing, finally in Ultrasonic Bathe with DIW of high purity. Air drying in clean room class 10,000. Quality control at all stages of the treatment, including on-line SEM-EDS control and periodical XPS and optical profilometry tests. The blasting media used in the Process is an apatite born Calcium Phosphate having approximate chemical composition of Ca3(PO4) (Tri-Calcium Phosphate) with hardness estimated as 5 by the Mohs scale of hardness, as compared to 9 for Alumina. 2 mm The <300 μm particles of the apatite abrasive. 4

6 RBM implants comparative tests - SEM general view Test Results of NOVA RBM implants, which show their full identity to other RBM implant leaders in the field. SEM (Scanning Electron Microscope) - General view, Magnification X 10 Lifecore Biomedical RBM Implant NOVA RBM Implant sample APA-S NOVA RBM Implant sample a-gamma 2 mm 2 mm CONCLUSION: All three implants have gained identically clean microporous homogeneous surface. SEM (Scanning Electron Microscope) - surface structure (morphology) Lifecore Biomedical RBM Implant (X 500 magnification) NOVA RBM Implant samples APA-S and a-gamma (X 2000 mag.) Osstem(**) RBM Implant MAGNIFICATION X X 4000 * www. trycare.co.uk/ techdata_pdfs/106. pdf X 2000 ** www. chirurgiaorale. altervista.org/ Ostem/ostem/ RBM_Research.pdf 2 mm X 1000 CONCLUSION: All implants have an identical surface, and features intensive developed morphology with sharp boundaries, without special geometry. 5

7 Roughness by optical pro filometer Test s results of roughness measurement by optical profilometer, for NOVA Implants RBM implant, sample APA-P TECHNION IIT Title: Note: Surface statistics Rq Ra Rv Rp Rt X Y Ht Dist Angle um 1.94 um um um um Date Time Measurement Mode Fov Objective Pixel size um um um um 05/09/ :15:43 VSR 1.0 X 50 X mm 6

8 Comparative Results Comparative results of the main roughness parameter Ra value, for dental implant surface: Company Lifecore Osstem NOVA Implants Implant RBM implant RBM implant RBM implant Source (*) (**) Above test results Ra, microns * www. trycare.co.uk/ techdata_pdfs/106. pdf ** www. chirurgiaorale. altervista.org/ ostem/ostem/ RBM_Research.pdf Test instrument or way of derivation Ra is calculated following the Lifecore web page definition: Lifecore s RBM surface offers approximately 250% greater surface roughness (Ra) than a traditional machined surface, the last is roughly estimated as of 0.5 microns The Ra value as defined at the Osstem web page from the above profile image Veeco Optical Profilometer Conclusion: The surface of NOVA Implants RBM implants has homogeneous roughness with Ra statistical value of 1.9 microns, within a range declared as optimal by leaders in the field. Surface chemistry & purity of NOVA Implants RBM implants as tested by SEM-EDS (Scanning Electron Microscope and Energy Distribution Spectrum) NOVA Implants RBM sample identification: APA-S a-gamma a-beta SEM microphotograph, magnification X500: EDS (*): Conclusion: SEM microphotographs show absolutely clean porous surface of the implants, while EDS chemical analysis at any point of the surface show regular chemical composition of Ti-Al-V alloy with no contaminations. (*)The spectra were obtained from the random points on the surface as seen by the microphotograph, while absolutely identical spectra were revealed on any point of the tested surface. The high pick on the spectrum is responsible for Ti, the left small is responsible for Al, and the right small one for V. 7

9 Implant customers will benefit from RBM implants www. chirurgiaorale. altervista.org/ Ostem/ostem/ RBM_Research.pdf Chemical composition of dental implants surface as tested by X-ray Photoelectron Spectroscopy (XPS) Element concentration, atomic %, as defined at the Company Implant source measure point by XPS Ti O C AI V N Ca Zn Si P RBM implant, XPS test NOVA sample APAX- for this Implants , top research section NOVA Implants Osstem RBM implant, sample APAX , screw section RBM implant XPS test for this research (*) Conclusions: 1.Main chemical components detected on the surface (Ti, O, C) are of identical level for both NOVA Implants and Osstem implants (Al and V at the NOVA Implants are on the usual level for Ti6Al4V alloy, while their absence in the Osstem case may point out on using of pure Titanium for implants manufacturing). 2. Traces of Ca and P are remains of biocompatible blasting media (Calcium Phosphate) used in both cases. 3. Other negligible traces are common for both cases and constitute remains of materials used at various stages of the surface treatment process. Benefits The surface structure (morphology) of the NOVA Implants RBM dental implants, as exposed by SEM mi crophotographs, is identical to that of the leading companies in the field and is featured by highly developed surface porosity. The surface roughness of the NOVA Implants RBM dental implants is well-defined and uniform. The main roughness parameter Ra has good acceptable value of 1.9 microns, which falls in the range of this parameter as declared by the leaders in the field. The surface purity of the NOVA Implants RBM dental implants, as exposed by SEM micropho-tographs and checked by EDS-SEM instrument, is nearly absolute: no inclusions or contaminations are detected, any point of the surface is revealed to be pure Titanium alloy. The surface chemical composition of the NOVA Implants RBM dental implants, as analyzed by XPS instrument, represents well acceptable values of the main elements usually found on the dental implants surface that underwent blasting and blasting media cleaning, and is comparable to that of the leaders in the field. 8

10 Implant System - PSI Nova Implants are taperd internal hex implants, designed to enable easy insertion while supporting excellent initial stability. The variable thread design enables self tapping, thus providing superb solutions for a variety of bone conditions. All our implants are made of the titanium alloy Ti-6Al-4V ELI, in accordance with ASTM-F Titanium has the outstanding capability to integrate almost completely with the bone. This unique charactaristic coupled with its meatalorgic advantages of strength & endurance makes titanium the ideal implant material. In addition it can be precisely machined to ensure a range of implants that meets the requirements of modern state of the art Prosthetics. All our implants can be ordered with the regular SLA surface treatment or the new RBM more advanced surface treatment. Nova Implants multi-design features offers an excellent solution for immediate placement and immediate loading. One platform fits all implant diameters. Packaging has been designed for quick identification and easy opening. Nova Implants adhere to the highest international standards of manufacturing and have the ISO standards Institute and CE approval. Clinical Benefits: Better control during placement. Greater initial placement stability. Self drilling, super self-tapping feature. Self-condensing. Self-directing in line of insertion. Product Identification NAME DIAMETER LENGTH PSI L8 Color Identification - implants RED 3.30mm BLUE 3.75mm GREEN 4.20mm BLACK 5.00mm BROWN 6.00mm 9

11 Implant System - PSI ø 3.3 mm ø 3.3 mm PSI-3.3-L8 PSI-3.3-L10 PSI-3.3-L11.5 PSI-3.3-L13 PSI-3.3-L16 8 mm 11.5 mm 16 mm Surface Treatment ø ø PSI-3.75-L8 PSI-3.75-L10 PSI-3.75-L11.5 PSI-3.75-L13 PSI-3.75-L16 8 mm 11.5 mm 16 mm Surface Treatment ø 4.2 mm ø 4.2 mm PSI-4.2-L8 PSI-4.2-L10 PSI-4.2-L11.5 PSI-4.2-L13 PSI-4.2-L16 8 mm 11.5 mm 16 mm Surface Treatment 10

12 Implant System - PSI ø 5.0 mm ø 5.0 mm PSI-5-L8 PSI-5.-L10 PSI-5-L mm 11.5 mm Surface Treatment ø 6.0 mm PSI-5-L13 PSI-5.0-L16 16 mm ø 6.0 mm PSI-6-L8 PSI-6-L10 PSI-6-L11.5 PSI-6-L13 8 mm 11.5 mm Surface Treatment Color Identification - drills Implant Procedures drill point MD 100 drill-1.20 DR 0020 DR 5032 drill BLUE 3.20mm GREEN 3.65mm BLACK 4.20mm DR 5028 drill DR 5028 drill BROWN 5.20mm PSI -BONE TYPE, PCI -BONE TYPE DR 5042 drill-4.2 DR drill-3.65 ø3.75mm To be used at the begining of each procedure RED 2.80mm DR 5032 drill DR 5028 drill ø4.2mm DR 5032 drill DR drill-3.65 DR 5028 drill ø5mm DR 5032 drill DR drill-3.65 DR 5048 drill-5.2 DR 5042 drill-4.2 ø6mm

13 Implant System - PCI The Nova PCI implant is a straight wall 2.5 mm internal hex implant (standard) for both two-stage and single stage procedures. This design has a larger surface area that increases the bone to implant contact, resulting in more surface area for bone-cell attachment and interaction with the osteoblasts. The Nova PCI implant is self drilling, with a unique wide threads design, with tapered threads on the apical part for self tapping. It can be used with all bone types, but is specially recommended for bone type 1. All our implants can be ordered with the regular SLA surface treatment or the new RBM more advanced surface treatment. Product Identification NAME DIAMETER LENGTH PCI L8 Color Identification - implants RED 3.30mm BLUE 3.75mm GREEN 4.20mm BLACK 5.00mm BROWN 6.00mm 12

14 Implant System - PCI ø 3.3 mm ø 3.3 mm PCI-3.3-L8 PCI-3.3-L10 PCI-3.3-L11.5 PCI-3.3-L13 PCI-3.3-L16 8 mm 11.5 mm 16 mm Surface Treatment ø ø PCI-3.75-L8 PCI-3.75-L10 PCI-3.75-L11.5 PCI-3.75-L13 PCI-3.75-L16 8 mm 11.5 mm 16 mm Surface Treatment ø 4.2 mm ø 4.2 mm PCI-4.2-L8 PCI-4.2-L10 PCI-4.2-L11.5 PCI-4.2-L13 PCI-4.2-L16 8 mm 11.5 mm 16 mm Surface Treatment 13

15 Implant System - PCI ø 5.0 mm ø 5.0 mm PCI-5-L8 PCI-5-L10 PCI-5-L11.5 PCI-5-L13 PCI-5-L16 8 mm 11.5 mm 16 mm Surface Treatment ø 6.0 mm ø 6.0 mm PCI-6-L8 PCI-6-L10 PCI-6-L11.5 PCI-6-L13 8 mm 11.5 mm Surface Treatment Color Identification - drills Implant Procedures drill point MD 100 DR 5032 drill ø3.3 mm GREEN 3.65mm BLACK 4.20mm BROWN 5.20mm PSI -BONE TYPE, PCI -BONE TYPE DR 5042 drill-4.2 DR 5028 DR 5032 drill drill ø BLUE 3.20mm DR drill-3.65 DR 5028 drill DR 5028 drill drill-1.20 DR 0020 RED 2.80mm DR 5028 drill ø4.2 mm DR 5032 drill DR drill-3.65 DR 5028 drill ø5 mm DR 5032 drill DR 5048 drill-5.2 DR DR 5042 drill-3.65 drill-4.2 ø6 mm To be used at the begining of each procedure 14

16 One Stage System - DV A one piece implant and abutment (one stage) is available in 2.8 mm, 3.3mm, 3.6mm and 4.2mm diameters. The Nova one stage system is suitable for cases of narrow ridges or closed spaces between the teeth. It can also be used for immediate loading in all types of bone. All our implants can be ordered with the regular SLA surface treatment or the new RBM more advanced surface treatment. Both are conductive to bone. The transgingival neck with titanium oxide coating is placed at bone level. Placement: Make a pilot drilling (2mm) and using the plastic mount and Nova driver (2.1 mm) to place the implant. The abutment, if required, can support the provisional prosthesis. Impression: Use the plastic impression copying and the Nova analog. Product Identification NAME DIAMETER LENGTH DV L13 Color Identification - implants YELLOW 2.80mm RED 3.30mm BLUE 3.60mm GREEN 4.20mm ø 2.8 mm ø 2.8 mm DV-2.8-L10 DV-2.8-L11.5 DV2.8-L13 DV2.8-L mm 15 mm Surface Treatment ø 3.3 mm ø 3.30 mm DV-3.3-L10 DV-3.3-L11.5 DV-3.3-L13 DV-3.3-L mm 15 mm Surface Treatment 15

17 One Stage System - DV ø 3.6 mm ø 3.6 mm DV-3.6-L10 DV-3.6-L11.5 ø 4.2 mm 11.5 mm Surface Treatment DV3.6-L13 DV-3.6-L15 15 mm ø 4.2 mm DV-4.2-L10 DV-4.2-L11.5 DV-4.2-L13 DV-4.2-L15 Implant Procedures 11.5 mm Surface Treatment YELLOW 2.50mm RED 2.80mm BLUE 3.20mm drill NDI 3.2O drill NDI 2.5O ø2.8 mm 15 mm GREEN 3.65mm drill NDI 2.8O drill NDI 2.5O drill-1.20 DR 0020 Color Identification - drills WHITE 1.20mm drill point MD 100 drill drill NDI 2.5O NDI 2.8O ø3.3 mm drill drill drill NDI 2.5O NDI 2.8O NDI 3.2O ø3.65 mm ø4.2 mm To be used at the begining of each procedure 16

18 Orthodontic Anchor Screw The Nova MOI Orthodontic anchor screws are used as an anchor system for improving anchorage efficiency during the orthodontic treatment. The Nova MOI is self Tapping for quick and easy use. Due to its temporary function the surface of the titanium is not treated by sand blasting/acid-etch. ø 1.2 mm ø 1.20 mm MOI-1.2-L6 MOI-1.2-L8 MOI-1.2-L10 MOI-1.2-L mm 8 mm 11.5 mm ø 1.5 mm ø 1.50 mm MOI-1.5-L6 MOI-1.5-L8 MOI-1.5-L10 MOI-1.5-L mm 8 mm 11.5 mm 17

19 Orthodontic Anchor Screw ø 2.0 mm ø 2.0 mm MOI-2-L6 MOI-2-L8 MOI-2-L10 MOI-2-L mm 8 mm 11.5 mm ø 2.5 mm ø 2.5 mm MOI-2.5-L6 MOI-2.5-L8 MOI-2.5-L10 MOI-2.5-L mm 8 mm 11.5 mm 18

20 Healing Caps The healing cap is used as a covering for the implant to prevent bone and tissue growth over the implant during osseointegration. The healing caps are taller than cover caps, and usually remain in place for about 3-6 months to allow the gum tissue to form around the shape of the cap. Healing caps also help to keep the gum tissue pushed back so that a crown or abutment can be easily fitted. ø 4.7 mm Standard ø 4.70 mm HC-4020 HC-4030 HC-4040 HC-4050 HC-4060 HC-4070 Collar 2 mm 3 mm 4 mm 5 mm 6 mm 7 mm Collar 8 mm 11 mm 12 mm ø Narrow ø HC-3020 HC-3030 HC-4040 HC-3050 HC-3060 HC-3070 Collar Collar 2 mm 3 mm 4 mm 5 mm 6 mm 7 mm 8 mm 11 mm 12 mm ø mm Wide ø mm HCW-6030 HCW-6040 HCW-6050 HCW-6060 Collar Collar 3 mm 4 mm 5 mm 6 mm 11 mm 12 mm 19

21 Premium Healing Caps ø 4.7 mm PREMIUM Standard ø 4.70 mm PMI 5002 PMI 5003 PMI 5004 PMI 5005 PMI 5006 PMI 5007 Collar Collar 2 mm 3 mm 4 mm 5 mm 6 mm 7 mm 8 mm 11 mm 12 mm Material TI4V6AL-ELI TI4V6AL-ELI TI4V6AL-ELI TI4V6AL-ELI TI4V6AL-ELI TI4V6AL-ELI ø PREMIUM Narrow ø PMI 5102 PMI 5103 PMI 5104 PMI 5105 PMI 5106 PMI 5107 Collar Collar 2 mm 3 mm 4 mm 5 mm 6 mm 7 mm 8 mm 11 mm 12 mm Material TI4V6AL-ELI TI4V6AL-ELI TI4V6AL-ELI TI4V6AL-ELI TI4V6AL-ELI TI4V6AL-ELI ø 6.0 mm PREMIUM Wide ø 6.0 mm PMI 5203 PMI 5204 PMI 5205 PMI 5206 Collar Collar 3 mm 4 mm 5 mm 6 mm 11 mm 12 mm Material TI4V6AL-ELI TI4V6AL-ELI TI4V6AL-ELI TI4V6AL-ELI 20

22 Prosthetic Standard Abutments Straight ST-1109 Long ST-1113 ø 3.80 mm Narrow ø 3.80 mm STN mm 3.80 mm Where standard crown and bridge techniques are desired, use the Nova Narrow Abutment with single-unit restorations. Nova Narrow Abutments should be used when the interdental space is limited and is compatible with the internal conical connection. 21 Nova manufactures top quality prosthetic abutments. Use with the SRR 9.4 mm standard screw and the standard a 1.25mm hex driver.

23 Prosthetic Standard Abutments with Shoulder STA-4710 STA-4712 STA-4713 STA mm 12 mm Shoulder 1 mm 2 mm 3 mm 4 mm Shoulder Anatomic Straight SLM-3810 SLM-3812 SLM-3813 Height 1 mm 2 mm 3 mm 11 mm Height Anatomic NEW SCM-3010 SCM-3020 SCM-3030 Height 1 mm 2 mm 3 mm Height 11 mm Esthetic Abutments are pre-milled from titanium and are designed with scalloped margins that profile natural soft tissue contours. They are used where standard crown and bridge techniques are desired, with single and multiple-unit restorations. Esthetic Abutments are available with various collar heights based on implant platform and system. Nova manufactures top quality prosthetic abutments. Use with the SRR 9.4 mm standard screw and the standard a 1.25mm hex driver. 22

24 Prosthetic Angulated 15 Abutments Standard 15 ASM-1115 ASM-1315 Angle ø 3.80 mm Narrow 15 ø 3.80 mm ANS-1115 Angle 15 Nova manufactures top quality prosthetic abutments. Use with the SRR 7.8 mm standard screw and the standard a 1.25mm hex driver. Anatomic 15 ANG ANG ANG Angle Height Height 1.00 mm 2.00 mm 3.00 mm 11 mm 23 Nova manufactures top quality prosthetic abutments. Use with the SRR 8.3 mm standard screw and the standard a 1.25mm hex driver.

25 Prosthetic Angulated 25 Abutments Standard 25 ASM-1125 ASM-1325 Angle ø 3.8 mm Narrow 25 ø 3.80 mm ANS-1215 Angle 25 Nova manufactures top quality prosthetic abutments. Use with the SRR 7.8 mm standard screw and the standard a 1.25mm hex driver. Anatomic 25 ANG ANG ANG Angle Height Height 1.00 mm 2.00 mm 3.00 mm 11 mm Nova manufactures top quality prosthetic abutments. Use with the SRR 8.3 mm standard screw and the standard a 1.25mm hex driver. 24

26 Prosthetic Angulated 15 and 25 Abutments Esthetic Abutments are pre-milled from titanium and are designed with scalloped margins that profile natural soft tissue contours. They are used where standard crown and bridge techniques are required, with single and multiple-unit restorations. Esthetic Abutments are available with various collar heights based on implant platform and system. Anatomic 15 NEW ANT ANT ANT Angle Height Height 1 mm 2 mm 3 mm 11 mm Anatomic 25 NEW ANT ANT ANT Angle Height 1 mm 2 mm 3 mm Height 11 mm 12 mm 25 Nova manufactures top quality prosthetic abutments. Use with the SRR 8.3 mm standard screw and the standard a 1.25mm hex driver.

27 Prosthetic Angulated 35 and 45 Abutments 35 ASM-1135 Angle mm 45 ASM-1145 Angle mm Nova manufactures top quality prosthetic abutments. Use with the SRR 8.3 mm standard screw and the standard a 1.25mm hex driver. 26

28 Ball Attachments The titanium Nova Ball Attachment provides firm retention and stabilization of the overdenture when it is used with tissue-supported implant-retained overdentures. The titanium Nova Ball Attachment is compatible with internal hex. ø 4.00 mm Standard ø 4.00 mm BAT-0010 BAT-0020 BAT-0030 BAT-0040 BAT-0050 BAT-0060 Height 1.00 mm 2.00 mm 3.00 mm 4.00 mm 5.00 mm 6.00 mm 8 mm 11 mm 12 mm Covers and Caps HUS SIL 0001 SIS 0002 SIH 0003 Placement Ball Cover Cap Cap Cap Material Metal Silicone Silicone Silicone Finish Standard Soft Hard 27

29 Impression Copings Closed Tray TRANSFER PICK-UP ø 4.70 mm ø 4.70 mm TRS-0010 Material STAINLESS STEEL Closed Tray TRANSFER PLASTIC CUP TPC mm Material PLASTIC Closed Tray TRANSFER TMC-0910 TMC-0930 Height 1 mm 3 mm Hight Material TI4V6AL - ELI TI4V6AL - ELI 28

30 Impression Copings Open Tray IMPRESSION COPING ø 4.70 mm ø 4.70 mm TRO-1309 TRO-1310 Material STAINLESS STEEL STAINLESS STEEL TRANSFER SCREW SCR-8000 Material STAINLESS STEEL ABUTMENT SCREWS SRR -7.8 SRR -8.3 SRR -9.4 Height 7.8 mm 8.3 mm 9.4 mm Final Torque 30 Ncm 30 Ncm 30 Ncm Material TI4V6AL - ELI TI4V6AL - ELI TI4V6AL - ELI Packaged with Angulated Abutments Angulated Abutments Straight & UCLA Abutments Fits all Nova Abutments Universal 1.25 mm Hex Driver 29

31 Esthetic Abutments Components CONNECTIONS ø 4.50 mm ø 4.50 mm SPW-1005 SPW-1015 SPW-1025 Abutment 0.50 mm 1.50 mm 2.50 mm Hight 6 mm 7 mm 8 mm ø 4.50 mm PLASTIC SLEEVE ø 4.50 mm PTS mm CONNECTION SCREW SRS mm 30

32 Abutment Sleeves Delrin Hex And Non-Hex Plastic Sleeve ø 4.50 mm ø 4.50 mm PIS-0012 PIS-0013 Hex - 12 mm 12 mm Material PLASTIC - WHITE PLASTIC - RED ø 6.00 mm Delrin WIDE Hex and Non-Hex Plastic Sleeve ø 6.00 mm PIW-6012 PIW-6013 Hex - 12 mm 12 mm Material PLASTIC - WHITE PLASTIC - WHITE ø 6.00 mm Custom Titanium Castable Abutments (UCLA) ø 6.00 mm PTA-1312 Hex 12 mm Material PLASTIC & TITANIUM 31

33 Plastic Anatomic Abutments Angulated 15 PAN PAN PAN Angle Height 1.00 mm 2.00 mm 3.00 mm 11 mm Angulated 25 PAN PAN Angle Height 1.00 mm 2.00 mm Nova manufactures top quality prosthetic abutments. Use with the SRR 8.3 mm standard screw and the standard a 1.25mm hex driver. 32

34 Zirconium Abutments Standard ZRX-0910 ZRX-1110 ZRX-1111 Height 1 mm 2 mm 3 mm 11 mm Height Nova manufactures top quality prosthetic abutments. Use with the SRR 9.4 mm standard screw and the standard a 1.25mm hex driver. Angulated 15 ZRX ZRX ZRX-ZRX Angle Height 1 mm 2 mm 3 mm Height 11 mm Angulated 25 ZRX ZRX Angle Height 1 mm 2 mm Hight 33 Nova manufactures top quality prosthetic abutments. Use with the SRR 9.4 mm standard screw and the standard a 1.25mm hex driver.

35 Implant Analogs ø 3.30 mm ø 3.30 mm ADV mm Material STAINLESS STEEL Suitable for use with the One Stage Implants and Abutments System ø 4.00 mm ø 4.00 mm ANL-0001 ANL mm 12 mm Material STAINLESS STEEL TI4V6AL - ELI Suitable for use with the PSI Implants 34

36 Drills and Countersinks DR 5019 Round Bur without irrigation ø 1. DR 5020 Pilot Drill ø 2.0 mm DR 5028 Drills ø 2.8 mm DR 5032 ø 3.2 mm DR 5038 ø 3.8 mm DR 5042 ø 4.2 mm ø 4.8 mm DR 5048 TDS 280 L10 Short TDS 420 L10 TDL 250 L20 Long TDS 320 L20 TDC 25X37 L 16 Conical TDC 27X45 L 16 TDC 18X24 L 16 TDC 31X55 L 16 DR 3842 DR 5052 DR 5060 Countersink ø mm ø 5.2 mm ø 5-6 mm TB 2.0X3.0 L 16 Trephine Burr TB 3.0X4.0 L TB 4.0X5.0 L 16

37 Implant Tools Hex Drive Measure for Drill Depth DP 3040 HD 2507 HD 2510 HD 2515 HD 4507 HD 4510 HD L7 mm 1.25 L 1.25 L15 mm 2.42 L7 mm 2.42 L 2.42 L15 mm Motor Mount Hex 1.25 L22 mm / 1.25 L28 mm MG 2522 / MG 2528 Motor Mount Hex 2.42 L20 mm / 2.42 L28 mm Hand Ratchet MG 4220 / MG 4228 HR 2050 Hand Driver for DV Nova One Stage Implants AR 2060 Hand Driver Hex KT 2510 / KT L & 1.25 L15 mm Cover Screw CS

38 Implant Tools AR 2040 Surgical Screw Driver Hex 6.35 mm LABK 1010 Laboratory Screw Driver Hex 1.25 mm RC 2030 Ratchet KIT CAT No. PRODUCT DR-5019 Round Bur Ø 1.9 without irrigation DR-5020 Pilot Drill Ø =2.0mm DR-5028 Drill Ø =2.8mm DR-5032 Drill Ø =3.2mm DR-5038 Drill Ø =3.8mm DR-5042 Drill Ø =4.2mm DR-5048 Drill Ø =4.8mm GP-1020 Guide Pin 10mm x 2 GP-1320 Guide Pin 13mm x 2 HD-2507 Hex Driver 1.25 L 7mm HD-2510 Hex Driver 1.25 L10mm HD-4507 Hex Driver 2.42 L 7mm HD-4515 Hex Driver 2.42 L15mm MG-2422 Motor Mount 2.42 Hex L28mm MG-2522 Motor Mount 1.25 Hex L22mm MG-2528 Motor Mount 2.42 Hex L20mm RC-2030 Ratchet Drill Extension MC-0001 Metal Container 37

39 Packaging All Nova implants come in a sterile double pack. The transparent outer blister contains a vial that holds the pre-mounted implant and cover screw. The implant type, diameter and length is displayed on a sticker that is also placed within the blister pack. Medical Symbols STERILE 2! R Sterlized using irradation. Sterility guaranteed if pack unopened or undamaged. For single use only. Reference to the hazards in the operating instructions. Expiry date Use by YYYY-MM LOT CAT Lot number Catalogue number CE certification marking 38

40 Step by Step Blister Pack Before beginning the procedure make sure surgical gloves are worn. Peel back the blister cover to reveal the vial. Remove vial from pack as shown below. 3 ways to remove the implant from the vial 1. Removing the implant from the vial using the hand ratchet (RC 2030) - Gently loosen the seal by rotating it with the use of the hand ratchet. -Slowly pull out the implant from the vial. 2. Removing the implant from the vial using a wrench (AR 2040) - Connect the wrench to the seal. - Gently loosen the seal by rotating it with the use of the wrench. - Slowly pull the implant out of the vial. 3. Removing the implant from the vial using a surgical screwdriver (KT 2510 / 2515) - Connect the surgical screwdriver to the seal. - Gently loosen the seal by rotating it with the use of the surgical screwdriver. - Slowly pull the implant out of the vial. 39

41 Procedures Implant & Healing Cap Abutment Impression Transfer Model Casting Transfer & Abutment GIPS Abutment Preparation GIPS Final Restoration Implants & Healing Cap Abutment OR Direct Impression Transfer Ball System Elements GIPS GIPS Implant Level Impression Final Restoration 40

42 User Instructions Description: Nova Implants are manufactured from bio compatible titanium and titanium alloy and abutments from titanium or titanium alloy. Nova Implants and Abutments include various surface treatments and coatings. Other restorative components are manufactured with titanium or titanium alloy, stainless steel and a variety of polymers. For specific product description refer to individual product labels. Indications for Use: Nova Implants are intended for surgical placement in the upper or lower jaw to provide a means for prosthetic attachment in single tooth restorations and in partially or fully edentulous spans with multiple single teeth utilizing delayed or immediate loading, or as a terminal or intermediary abutment for fixed or removable bridgework, and to retain over dentures. Nova Implants are intended for immediate function on single tooth and/or multiple tooth applications when good primary stability is achieved, with appropriate occlusal loading, in order to restore chewing function. Additional Indications: Nova Dental Abutments and Over denture Bars are intended for use as an accessory to end osseous dental implants to support a prosthetic device in a partially or edentulous patient. These are intended for use to support single and multiple tooth prostheses, in the mandible or maxilla. The prostheses can be screw or cement retained to the abutment. PEEK Abutment Posts and Temporary Cylinders are intended for use as an accessory to end osseous dental implants to support a prosthetic device in a partially or fully edentulous patient. These are intended for use to support single and multiple unit prostheses in the mandible or maxilla for up to 180 days during end osseous and gingival healing, and are for non occlusal loading of single and multiple unit provision al restorations. The prostheses can be screw and/or cement retained to the abutment. These Temporary Posts and Cylinders require a minimum inter arch space of 6mm and a maximum angulation of 15. These also allow for occlusal loading of single and multiple unit restorations of integrated implants for guided soft tissue healing. The Quick Bridge Provisional Components are intended to be mated with Nova Conical Abutments for use as an accessory to end osseous dental implants to support a prosthetic device in a partially or fully edentulous patient. Contraindications: Placement of dental implants may be precluded by patient conditions that are contraindications for surgery. Nova Implants should not be placed in patients where the remaining jaw bone is too diminished to provide adequate implant stability. Cardiac conditions involving the risk of endocarditis, coronary insufficiency blood dyscrasias, cardiovascular disorders, patients on anticoagulant Rx A.I.D.S., cancers and chemotherapeutic treatments, corticosteroids treatment radiotherapy of the cervico-facial region osteoporosis, uncontrolled or insulindependant diabetes pregnancy, endocrine disorders. Possible contraindications Poor oral hygiene, bruxism alcoholism, smoking, drug abuse psychological problems aggressive behavior. Temporary contraindications Systemic infection, local oral or respiratory infection. Local contraindications Insufficient alveolar bone width and height to ensure the encompassing of the implant with at least one millimeter of bone Infections, cysts, tumors, periodontal disease, prostodontic problems Storage and Handling: Devices should be stored at room temperature. Refer to individual product labels and the Surgical Manual for special storage or handling conditions. Warnings: Excessive bone loss or breakage of a dental implant or restorative device may occur when an implant or abutment is loaded beyond its functional capability. Physiological and anatomic conditions may negatively affect the performance of dental implants. The following should be taken into consideration when placing dental implants: - Poor bone quality- - Poor oral hygiene - Medical conditions such as blood disorders or uncontrolled hormonal conditions It is recommended that small diameter implants not be restored with angled abutments in the molar region. Mishandling of small components inside the patients mouth carries a risk of aspiration and/or swallowing. Forcing the implant into the osteotomy deeper than the depth established by the drills can result in: stripping the driver hex interface inside the implant, stripping the driver, cold welding of the mount-driver interface to the implant, or stripping the walls of the osteotomy that may prevent an effective initial implant fixation. Clinical data have demonstrated enhanced performance of OSSEOTITE Implants as compared to other Nova Implants in patients with poor quality bone. Precautions: For safe and effective use of Nova Implants, abutments and other surgical and restorative dental accessories, these products or devices should only be used by trained professionals. The surgical and restorative techniques required to properly utilize these devices are highly specialized and complex procedures. Improper technique can lead to implant failure, loss of supporting bone, restoration fracture, screw loosening and aspiration. Sterility: All dental implants and some abutments are supplied sterile and are sterilized by an appropriate validated method. Refer to individual product labels for sterilization information; all sterile products are labeled STERILE. All products sold sterile are for single use before the expiration date printed on the product label. Do not use sterile products if the packaging has been damaged or previously opened. Do not re-sterilize or autoclave except where instructions to do so are provided on the product label, in the Surgical Manual, in the Restorative Manual or in any additional marketing literature for that product. Products provided nonsterile must be cleaned and sterilized according to the directions found in Surgical Manuals prior to use. Procedural Precautions, Surgery: For a detailed explanation of the procedural precautions refer to the Surgical Manual. During the planning phase, it is important to determine the vertical dimension, the actual space available between the alveolar crest and the opposing dentition, in order to confirm that the available space will accommodate the proposed abutment and the final crown restoration. This information varies with each patient and abutment; therefore it should be carefully evaluated before placing any dental implant. The final prosthesis should be designed prior to the placement of the dental implant. Utilize continuous irrigation with a cool, sterile irrigating solution to avoid excessive damage to the surrounding tissue and to prevent compromising osseo integration. This is mandatory during gall procedures. Avoid excessive pressure during preparation of the bone site. As the drilling speed varies based on the instrument and the surgical procedure, recommendations for speed can be found in the Surgical Manual. Only sharp instruments of the highest quality should be used for any surgical procedure involving bone. Minimizing trauma to the bone and surrounding tissue enhances the potential for successful osseo integration. In order to eliminate contaminants and other sources of infection, all non-sterile devices should be cleaned and/or sterilized prior to use, per the instructions on the individual product labels. Procedural Precautions, Restoration: The healing period varies depending on the quality of the bone at the implantation site, the tissue response to the implanted device and the surgeon s evaluation of the patient s bone density at the time of the surgical procedure. Excessive force applied to the dental implant should be avoided during the healing period. Proper occlusion should be evaluated on the implant restoration to avoid excessive force. Potential Adverse Events: Potential adverse events associated with the use of dental implants may include: - Failure to integrate - Loss of integration - Dehiscence requiring bone grafting - Perforation of the maxillary sinus, inferior border, lingual plate, labial plate, inferior alveolar canal, gingiva - Infection as reported by: abscess, fistula, suppuration, inflammation, radio lucency - Persistent pain, numbness, paresthesia - Hyperplasia - Excessive bone loss requiring intervention - Implant breakage or fracture - Systemic infection - Nerve injury. Techniques: - Determine local anatomy with the use of local X-rays and CT. etc. - Planning the site, the technique and the dimensions of the implant to be used. - Careful management and high precision is recommended. Caution: U.S. Federal Law restricts this device to sale by or on the order of a licensed dentist or physician. 41

43

44 ISO 9001:2008 ISO 13485:2003 MEDICAL DEVICES & DEVELOPMENT P.O.B. 2318, Kiryat Ono, 55122, Israel Tel: +972 (0) Telefax: +972 (0) Website: nova-implants.com

RBM dental implants by CST Process Technical Release September 2012

RBM dental implants by CST Process Technical Release September 2012 Page 1 of 7 RBM dental implants by CST Process Technical Release September 2012 Summary Finish Line operates technologically validated RBM (Resorbable Blasting Media) Process, based on its CST (Comprehensive

More information

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G

IQ IMPLANTS Smart Choice PRODUCT C ATA L O G IQ IMPLANTS Smart Choice PRODUCT C ATA L O G www.iqimplants.com info@iqimplants.com 2 TABLE OF CONTENTS GENERAL Company Profile 3 IMPLANTS 5 PROSTHETICS 13 TOOLS 27 3 COMPANY PROFILE IQ Implants Ltd. reflects

More information

Implant System MAKE IT SIMPLE

Implant System MAKE IT SIMPLE Implant System MAKE IT SIMPLE P. 4-5 P. 6-7 P. 8-9 P. 10-13 P. 14 P. 15-17 P. 18-19 P. 20-21 MIS Warranty: MIS exercises great care and effort in maintaining the superior quality of its products. All MIS

More information

NARROW DIAMETER implant

NARROW DIAMETER implant N NARROW IAMETER implant N Precision dental solutions C-Tech Implant is a dynamic company with aggressive growth, producing components and product lines primarily for dental implantology. International

More information

NARROW DIAMETER implant

NARROW DIAMETER implant ND NARROW DIAMETER implant TABLE OF CONTENTS ND - NARROW DIAMETER implant Implant characteristics page 04 Dental implant page 05 Open Tray Impression Transfer page 06 Titanium Abutments page 07 O-Ball

More information

Personal Attention Accurate Dental Solutions. Precision Down to the Smallest Detail. Wide Range of Dental Solutions Engineerd for a Lifetime

Personal Attention Accurate Dental Solutions. Precision Down to the Smallest Detail. Wide Range of Dental Solutions Engineerd for a Lifetime PRODUCT CATALOG Personal Attention Accurate Dental Solutions Precision Down to the Smallest Detail Wide Range of Dental Solutions Engineerd for a Lifetime Global Partners Table of Contents Company Profile

More information

NEW. An Extended Solution. for Narrow Ridges

NEW. An Extended Solution. for Narrow Ridges mm NEW An Extended Solution for Narrow Ridges NICE System: An Extended Solution for Narrow Ridges Quality Alpha-Bio Tec presents an advanced new NARROW implant solution for narrow ridges and tight spaces.

More information

Legacy Prosthetic Catalog

Legacy Prosthetic Catalog Legacy Prosthetic Catalog Straight Snap-On Straight Contoured Angled Contoured Ball Attachment Gold/Plastic Castable Locator Attachment Plastic Temporary Screw Receiving Plastic Non-Engaging Castable 15

More information

A self-tapping internal hex. implant by MAKE IT SIMPLE

A self-tapping internal hex. implant by MAKE IT SIMPLE A self-tapping internal hex. implant by MAKE IT SIMPLE P. 4-5 P. 6-7 P. 8 P. 9 P.10 P.11 P.12 P.13 P.14 P.15 P.16-17 P. 18-19 P. 20-21 P. 22 P. 23 P. 24-25 MIS Warranty: MIS exercises great care and effort

More information

Instructions for Use for dental implant

Instructions for Use for dental implant Instructions for Use for dental implant 1. Disclaimer of liability This product is part of the Cortex Dental Implant System and may only be used in conjunction with the corresponding original components

More information

NEW NEW. An Extended Solution for Narrow Ridges

NEW NEW. An Extended Solution for Narrow Ridges NEW mm NEW An Extended Solution for Narrow Ridges NICE System: An Extended Solution for Narrow Ridges Quality Alpha-Bio Tec presents an advanced new NARROW implant solution for narrow alveolar ridges and

More information

Where technology meets dentistry INNOVATION. at a GLANCE

Where technology meets dentistry INNOVATION. at a GLANCE Where technology meets dentistry INNOVATION at a GLANCE ABOUT PALTOP Paltop is a premium manufacturer of dental implants that strives to provide highest quality products in the dental arena. Leveraging

More information

NEW. An Extended Solution. for Narrow Ridges

NEW. An Extended Solution. for Narrow Ridges mm NEW An Extended Solution for Narrow Ridges NICE System: An Extended Solution for Narrow Ridges Quality Alpha-Bio Tec presents an advanced new NARROW implant solution. An addition to the existing range

More information

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag.

INDEX. Pag. 12. Pag. 05. Pag. 06. Pag. 13. Pag. 06. Pag. 14. Pag. 15. Pag. 15. Pag. 15. Pag. 15. Pag. 08. Pag. 16. Pag. 09. Pag. PROSTHESIS MANUAL INDEX PRESENTATION Pag. 05 CEMENT-SCREWED PROSTHESIS Pag. 12 INTRODUCTION PROSTHESIS MANUAL WARNINGS Pag. 06 Pag. 06 IMPRESSION TAKING: NECESSARY MATERIAL PROSTHESIS: NECESSARY MATERIAL

More information

4766 Research Dr. San Antonio, TX insightdentalsystems.com

4766 Research Dr. San Antonio, TX insightdentalsystems.com OVERVIEW OF THE INSIGHT DENTAL IMPLANT DELIVERY SYSTEM The IDS system comes in a unit dose implant system where its advantage provides sterile instrumentation in one single-use kit. It is organized to

More information

Biomimetic Product catalogue

Biomimetic Product catalogue Biomimetic Product catalogue 20 Pol. Industrial Santa Anna I Apartado 20 08251 Santpedor (Barcelona) España T. (+34) 902 38 38 48 F. (+34) 93 827 38 73 www.avinent.com avinent@avinent.com 1 CORAL is the

More information

Biomimetic PEARL. Product catalogue

Biomimetic PEARL. Product catalogue Biomimetic PEARL Product catalogue PEARL is the AVINENT system of mini implants, an innovative product with unique features that aims to provide a quality alternative to what is available today as regards

More information

contents the smarter case approach reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9

contents the smarter case approach reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9 simply fixed angled contents the smarter case approach 3-4 3 reasons to choose simplyintegrated 5 system overview 6 ordering 7 mount-free implants 8-9 SMART PACK prosthetics 10 simplyinteractive details

More information

RDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED

RDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED RDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED Introducing the new CIT Implant C ONFIDENCE I NSPIRING T ECHNOLOGY see more page.10 RDS IMPLANTS PERFECTLY DESIGNED - SIMPLY ASSIGNED TABLE OF CONTENTS

More information

SwissPlant Prosthetic Catalog. SwissPlant

SwissPlant Prosthetic Catalog. SwissPlant SwissPlant Prosthetic Catalog Contoured Snap-On Angled Contoured Ball Attachment Gold/Plastic Castable Locator Attachment Plastic Temporary Screw Receiving Plastic Non-Engaging Castable Narrow Titanium

More information

- RESTORATIVE PRODUCT CATALOG

- RESTORATIVE PRODUCT CATALOG - RESTORATIVE PRODUCT CATALOG MADE IN USA Others make Implants to sell... Tatum Surgical makes Implants to treat your Patients. Your Source for Implants To Meet Every Clinical Need Tatum... 4 Angled Post

More information

INTERNAL HEX ( ps) PLATFORM SHIFT PRESERVATION OF BONE NEVER LOOKED BETTER

INTERNAL HEX ( ps) PLATFORM SHIFT PRESERVATION OF BONE NEVER LOOKED BETTER INTERNAL HEX ( ps) PRESERVATION OF BONE NEVER LOOKED BETTER infinite opportunities in implantology For almost 50 years ACE Surgical has been dedicated to dental surgical advancements. We continue to develop

More information

Dental Implant Systems. Micro Precision Dental Devices

Dental Implant Systems. Micro Precision Dental Devices Dental Implant Systems Micro Precision Dental Devices About us TIDAL-SPIRAL IMPLANTS company profile Tidal-Spiral Implant Innovations established in 1992, as a unique, dynamic, rapidly expanding, high-tech

More information

Smarter Thinking. Simpler Design. Prima Plus. Surgical Manual

Smarter Thinking. Simpler Design. Prima Plus. Surgical Manual Smarter Thinking. Simpler Design. Prima Plus Surgical Manual TABLE OF CONTENTS PRIMA PLUS IMPLANT SURGICAL MANUAL SURGERY Prima Plus Characteristics 4 Surgical Considerations 5 Prima Plus Surgical Sequence

More information

product catalog

product catalog product catalog 2014-2015 02 Table of Contents About ADN 03 ntroduction About ADN... 3 Dental mplant Systems... 5 Surface Treatments... 6 nternal Conical Connection mplant Systems Touareg CloseFit mplant

More information

High-end solution STEP-BY-STEP USER GUIDE

High-end solution STEP-BY-STEP USER GUIDE High-end solution STEP-BY-STEP USER GUIDE System Contents REAL TIME Restoration Guided Conical drill Multi-Unit abutment, Conical connection Guided kit for conical connection implant procedure C1 & V3

More information

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray)

INSTRUCTIONS FOR THE DENTIST. synocta impression procedure, Screw-retained and Snap-on. Screw-retained (Open tray) Snap-on (Closed tray) INSTRUCTIONS FOR THE DENTIST synocta impression procedure, Screw-retained and Snap-on Screw-retained (Open tray) Snap-on (Closed tray) click 1. Attach synocta Impression caps to implants. Hand-tighten

More information

PRODUCT CATALOG / 1 /

PRODUCT CATALOG / 1 / PRODUCT CATALOG / 1 / Personal Attention Accurate Dental Solutions Precision Down to the Smallest Detail Wide Range of Dental Solutions Engineerd for a Lifetime Global Partners Table of Contents Company

More information

simply simply digital simply crown & bridge simply removable simply fixed simply à la carte

simply simply digital simply crown & bridge simply removable simply fixed simply à la carte TM crown & bridge fixed removable digital à la carte imagine... being able to order the way you treatment plan so you can focus on the dentistry, rather than the components knowing your treatment costs

More information

SimpleLine II Surgical / Prosthesis Manual

SimpleLine II Surgical / Prosthesis Manual SimpleLine II Surgical / Prosthesis Manual SimpleLine II SURGICAL MANUAL Surgical Drill Sequence 04 Fixture Installation 05 Fixture Connection 06 Surgical Kit Maintenance 08 Warnings 09 04 SimpleLine ll

More information

PHILOSOPHY SWISS QUALITY PERFORMANCE

PHILOSOPHY SWISS QUALITY PERFORMANCE SYSTEM OVERVIEW PHILOSOPHY TRI Dental Implants is an innovative provider of dental implant solutions from Switzerland. Join our unique approach in implant dentistry! Founder & CEO Tobias S. Richter 100%

More information

Utilizing Digital Treatment Planning and Guided Surgery in Conjunction with Narrow Body Implants. by Timothy F. Kosinski, DDS, MAGD

Utilizing Digital Treatment Planning and Guided Surgery in Conjunction with Narrow Body Implants. by Timothy F. Kosinski, DDS, MAGD Utilizing Digital Treatment Planning and Guided Surgery in Conjunction with Narrow Body Implants by Timothy F. Kosinski, DDS, MAGD Implant dentistry is undergoing some amazing transformations. With the

More information

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit

IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS. a perfect fit a perfect fit IMPRESSION-TAKING, BITE REGISTRATION, AND TEMPORARY RESTORATION ON CAMLOG IMPLANTS Open and closed impression-taking Impression-taking for option platform switching Bite registration Temporary

More information

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER

Product Chart. TOOLS The OSPOL tools fits with all components and both implant diameters. Ø 4,0 mm. Ø 3,35 mm DRILL KIT IMPLANT INSERTER Product Catalogue 1 Product Chart Follow the lines to see which products that fits both diameters and which that are special. In true OSPOL philosophy, most of the instruments and abutments fits both diameters.

More information

SwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD

SwishPlant. SwishPlant System Catalog. 4.8mmD mmD. 4.8mmD mmD. 3.7mmD mmD. 6.5mmD SwishPlant System Catalog ------------ 4.1mmD ------------ 3.7mmD ------------ 3.3mmD SwishPlant 6.5mmD ------------ 6.5mmD ------------ 5.7mmD Table of Contents SwishPlant Fixture Mount Packaging Page

More information

US Implant System 2013 PROSTHETIC PROCEDURE

US Implant System 2013 PROSTHETIC PROCEDURE US Implant System 2013 PROSTHETIC PROCEDURE Contents TS Implant System Cement retained restoration 06 Cement retained bridges with the Cement abutment system 18 Cement retained crown with the Angled abutment

More information

NEODENT GUIDED SURGERY

NEODENT GUIDED SURGERY NEODENT GUIDED SURGERY MANUAL Grand Morse Connection Helix Implant GRAND POSSIBILITIES WITH A LIMITLESS SOLUTION. GRAND MORSE NEODENT GUIDED SURGERY. 4 5 6 CONTENTS 1. CLINICAL STEP BY STEP OF GRAND

More information

introduction to BioHorizons prosthetics

introduction to BioHorizons prosthetics to BioHorizons prosthetics why choose BioHorizons prosthetics? BioHorizons offers a broad array of abutments for a wide range of restorative applications and individual needs including the versatile 3inOne

More information

Biomimetic PEARL. Product catalogue

Biomimetic PEARL. Product catalogue Biomimetic PEARL Product catalogue PEARL is the AVINENT system of mini implants, an innovative product with unique features that aims to provide a quality alternative to what is available today as regards

More information

Fixed Restoration for Atrophic Ridges

Fixed Restoration for Atrophic Ridges Fixed Restoration for Atrophic Ridges MIS Implants Technologies Ltd. All rights reserved. MIS Warranty: MIS exercises great care and effort in maintaining the superior quality of its products. All MIS

More information

Osteoconductive S.L.A. Surface. Fantastic surface, Bioseal, and Perfect achievement of CMI f ixation.

Osteoconductive S.L.A. Surface. Fantastic surface, Bioseal, and Perfect achievement of CMI f ixation. Fantastic surface, Bioseal, and Perfect achievement of CMI f ixation. Osteoconductive S.L.A. Surface No residual acid and cytotoxicity were observed in the surface examination. IS-II active Product Catalog

More information

Dental Implant Catalog All Rights Reserved

Dental Implant Catalog All Rights Reserved Dental Implant Catalog 2017 Dental Implant Catalog 2017 2 All Rights Reserved 3 About Contents Internal Hexagon Connection 6 Implantology made simple Medical Systems and Devices International Ltd. is a

More information

Legacy TM. System Catalog. Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4

Legacy TM. System Catalog. Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4 Legacy TM System Catalog Legacy TM 1 Legacy TM 2 Legacy TM 3 Legacy TM 4 Table of Contents Page # Design, Surface & Dimensions 1-5 6-13 Legacy TM 1, Legacy TM 2, Legacy TM 3 & Legacy TM 4 s Labeling &

More information

The REAL Mini Implant

The REAL Mini Implant by INTRA-LOCK The REAL Mini Implant IMMEDIATE LOAD STABILIZE DENTURES SIMPLIFIED PROCEDURE PROVISIONAL PROSTHETICS DIRECT PLACEMENT ENGINEERED EVOLUTION. Intra-Lock has elevated the engineering and delivery

More information

Astra Tech Implant System. Manual and product catalog OsseoSpeed TX Profile

Astra Tech Implant System. Manual and product catalog OsseoSpeed TX Profile Astra Tech Implant System Manual and product catalog OsseoSpeed TX Profile Adapting with nature OsseoSpeed TX Profile anatomically designed implants for sloped ridges Imagine being able to achieve 360

More information

The Uniti implant system is designed to be simple to learn and use. A seamless surgical protocol renders the system user friendly.

The Uniti implant system is designed to be simple to learn and use. A seamless surgical protocol renders the system user friendly. Surgical Manual The Uniti implant system is designed to be simple to learn and use. A seamless surgical protocol renders the system user friendly. For the experienced practitioner it will take no more

More information

Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants

Part 2: Internal Tri-Channel Connection. Nobel Biocare Compatible Components. Tri-Channel Internal Connection Implants Select Part 2 Internal Tri-Channel Connection Replace Select NobelSpeedy Replace NobelReplace and compatible implants listed below Select Part 2 contains only the Tri-Channel Internal Connection compatible

More information

User Manual Complete Prosthetic Kit (CPK)

User Manual Complete Prosthetic Kit (CPK) User Manual Complete Prosthetic Kit (CPK) The Complete Prosthetic Kit is designed to enable easy impression and transfer technique and to prevent the need to remove and to re-tighten the abutments. Advantages

More information

GMI. MONOLITH implant system. Surgical procedures guide

GMI. MONOLITH implant system. Surgical procedures guide GMI MONOLITH implant system Surgical procedures guide ABOUT THIS MANUAL This surgical procedures guide or surgical manual for the GMI MONOLITH implant system is designed solely to provide instructions

More information

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable.

PRODUCT CATALOG. Since 1985» Simple. Predictable. Profitable. PRODUCT CATALOG Since 1985» Simple. Predictable. Profitable. 2014 IMPLANTS HEALING PLUG INSERTERS COLLAGEN PRODUCTS 3.0mm Well Integra-CP Part No. DIAMETER LENGTH Price 345-306 4.5mm mm $280.00 345-308

More information

NARROW DIAMETER implant

NARROW DIAMETER implant NARROW IAMETER implant Impianto NARROW IAMETER Implant characteristics pag 04 ental Implants pag 06 Titanium healing abutments pag 06 Open tray impression transfer pag 07 Closed tray impression transfer

More information

Immediate loading in heavy smokers

Immediate loading in heavy smokers case report Immediate loading in heavy smokers Dr Dr Branislav Fatori & Dr Inge Schmitz, Germany Today, numerous implant systems and many modifications thereof are available on the market, and it may be

More information

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions

synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions synocta Meso abutment for cement-retained restorations PROSTHETICS Step-by-step instructions INTRODUCTION synocta Meso abutment for cement-retained restorations 1 The synocta Meso abutments, available

More information

SS Implant System 2013 PROSTHETIC PROCEDURE

SS Implant System 2013 PROSTHETIC PROCEDURE SS Implant System 2013 PROSTHETIC PROCEDURE Contents TS Implant System Cement retained restoration 06 Cement-retained bridges with the Solid abutment system (non-modified abutment) 16 Cement-retained bridges

More information

PRODUCT INFORMATION FOR CORTEX ABUTMENTS AND OTHER RESTORATIVE COMPONENTS

PRODUCT INFORMATION FOR CORTEX ABUTMENTS AND OTHER RESTORATIVE COMPONENTS PRODUCT INFORMATION FOR CORTEX ABUTMENTS AND OTHER RESTORATIVE COMPONENTS The Cortex Implants are intended for single or multiple replacements of lost teeth and provide a way to attach the prosthetic pieces

More information

NobelReplace Conical Connection Product overview

NobelReplace Conical Connection Product overview NobelReplace Conical Connection Product overview High primary stability, even in compromised bone situations1 The tapered implant body is designed for high primary stability and is ideal for Immediate

More information

GMI FRONTIER implant system. Surgical procedures guide

GMI FRONTIER implant system. Surgical procedures guide GMI implant system Surgical procedures guide ABOUT THIS MANUAL This surgical procedures guide or surgical manual for the GMI implant system is designed solely to provide instructions for using GMI products,

More information

InterActive System Catalog

InterActive System Catalog InterActive System Catalog Table of Contents Page # Implant Design & Surface 1 2-3 2 Implant Dimensions Fixture Mount & IQity Impression Technique 3 4-5 InterActive Implants Selection Chart 10-11 6-7 8

More information

Straumann Dental Implant System. Fax Order Form Collection.*

Straumann Dental Implant System. Fax Order Form Collection.* Straumann Dental Implant System. Fax Order Form Collection.* * The NNC Fax Order Form is still a stand alone document due to the unique restorative portfolio Straumann USA, LLC Tissue Level Implants for

More information

The LOCATOR concept. Simplicity and versatility for prosthesis fixation

The LOCATOR concept. Simplicity and versatility for prosthesis fixation The concept Simplicity and versatility for prosthesis fixation The concept Experience the freedom in prosthesis fixation Simple and secure fixation of implant-supported prostheses is essential for successful

More information

Alpha-Bio Tec specializes in the development and production of advanced dental solutions, focusing on the fields of implants and prosthetics. Over the

Alpha-Bio Tec specializes in the development and production of advanced dental solutions, focusing on the fields of implants and prosthetics. Over the Alpha-Bio Tec specializes in the development and production of advanced dental solutions, focusing on the fields of implants and prosthetics. Over the past few years the world of implantology has greatly

More information

How something small, can make such a big difference!! Your best choice in overdenture

How something small, can make such a big difference!! Your best choice in overdenture How something small, can make such a big difference!! Your best choice in overdenture Why? Kerator has the worldʼs most powerful competitiveness in overdenture attachment system. KERATOR was chosen over

More information

CAMLOG IMPLANT SYSTEM PRODUCT CATALOG

CAMLOG IMPLANT SYSTEM PRODUCT CATALOG a perfect fit CAMLOG IMPLANT SYSTEM PRODUCT CATALOG Valid from Janua y 2014 A partnership with CAMLOG encompasses the exceptional price-performance ratio of the CAMLOG Products and a custom-built service

More information

INTRODUCTION. Why Choose Cortex Prosthetics?

INTRODUCTION. Why Choose Cortex Prosthetics? Prosthetic Manual 4 INDEX Introduction 6-14 Impression Techniques 15-29 Abutments Selection Handling 30-33 Temporary Restorations 34-38 Screw Reiained Restorations 39-52 Removable Restorations 53-63 5

More information

INTRODUCTION. General Information. Important Warning

INTRODUCTION. General Information. Important Warning S u r g i c a l M a n u a l F o r M a g i x D e n t a l I m p l a n t INTRODUCTION General Information Read this manual carefully before starting treatment. This manual should be used as a reference guide

More information

Micro Production Part.

Micro Production Part. Micro Production Part www.mipro-inc.com Worldwide activity 3 Who we are 4 Materials 5 Surface Treatment 6 Packaging 7 Letter from CEO 8 Cover 10 SOI Implant 11-12 TOI Implant 13-14 NSI Implant 15-16 SHI

More information

GmbH DENTAL IMPLANT SYSTEMS PRODUCT CATALOG

GmbH DENTAL IMPLANT SYSTEMS PRODUCT CATALOG I M P L A N T GmbH DENTAL IMPLANT SYSTEMS PRODUCT CATALOG 2 ABOUT US GLOBAL IMPLANT GmbH is a Dental leading international company specializing in the development, manufacturing and marketing of Dental

More information

INTERNAL HEX Implant System

INTERNAL HEX Implant System Dental Implant Systems INTERNAL HEX Implant System infinite OPPORTUNITIES IN IMPLANTOLOGY For over 50 years ACE Surgical has been dedicated to dental surgical advancements. We continue to develop and manufacture

More information

Anchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282

Anchorage system. tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282 tomas / Sets Page 270 tomas / Pins Page 271 Instruments and accessories Page 273 Patient consultation material Page 282 266 . innovative comprehensive efficient. Dentaurum Online Shop shop.dentaurum.com

More information

Innovative Präzision Made in Germany

Innovative Präzision Made in Germany E OT-F 2 Surgical Manual Introduction The OT-F 2 implants are self-tapping cylindrical screw implants made of titanium grade 4 for insertion down to the bone crest level. The surgical protocol is usually

More information

Product Catalog. Since 1985» Simple. Predictable. Profitable.

Product Catalog. Since 1985» Simple. Predictable. Profitable. Product Catalog Since 1985» Simple. Predictable. Profitable. 2011 IMPLANTS 3.0mm Well Integra-CP Part No. DIAMETER LENGTH 345-306 4.5mm 6.0mm 345-308 4.5mm 8.0mm 345-311 4.5mm 11.0mm 350-305 5.0mm 5.0mm

More information

Product Catalog August 2018

Product Catalog August 2018 Product Catalog August 2018 2 Introducing the Hahn Tapered Implant System Combining decades of clinical experience with cutting-edge design, the Hahn Tapered Implant System is a contemporary dental implant

More information

Prosthodontic Procedure

Prosthodontic Procedure Prosthodontic Procedure TSH BNT Regeneration Implant Systems CAD-CAM Digital Solutions Services Important: before using Phibo The innovative and patented design of the Phibo implant systems incorporates

More information

SCREW-RETAINED RESTORATION LINE. THE MULTI UNIT ABUTMENT SYSTEM ON STRAIGHT and tilted IMPLANTS

SCREW-RETAINED RESTORATION LINE. THE MULTI UNIT ABUTMENT SYSTEM ON STRAIGHT and tilted IMPLANTS SCREW-RETAINED RESTORATION LINE THE MULTI UNIT ABUTMENT SYSTEM ON STRAIGHT and tilted IMPLANTS 2 SCREW-RETAINED RESTORATION LINE SCREW-RETAINED RESTORATION LINE 3 PROFESSIONAL SYSTEM FOR SUPERIOR ESTHETICS

More information

Product Catalog July 2017

Product Catalog July 2017 Product Catalog July 2017 1 2 Introducing the Hahn Tapered Implant System Combining decades of clinical experience with cutting-edge design, the Hahn Tapered Implant System is a contemporary dental implant

More information

Quick start Prosthetics

Quick start Prosthetics EN Quick start Prosthetics Easy and effective YELLOW PROSTHETIC PLATFORM QN CEMENTED RESTORATIONS ESTHETIC AUTMENTS OPEN TRAY POST IMPLANT ANALOG Indexed components with internal conical connection. 0.7

More information

InterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free

InterActive System CONICAL. Prosthetic Catalog. simplycrown & bridge SMART PACK. InterActive All-in-1 Packaging simplyinteractive Mount-Free InterActive System Prosthetic Catalog simplycrown & bridge SMART PACK InterActive All-in-1 Packaging simplyinteractive Mount-Free CONICAL Cover Screws, Healing Collars & Transfers Replacement Surgical

More information

ESTHETIC LINE implant

ESTHETIC LINE implant EL ESTHETIC LINE implant EL ESTHETIC LINE implant TABLE OF CONTENTS EL - ESTHETIC LINE implant Implant characteristics page 04 Dental implants page 05 Closed tray impression transfer page 06 Open tray

More information

UFII : Unique Fixture, 2 nd Generation. UFII Design Characteristics

UFII : Unique Fixture, 2 nd Generation. UFII Design Characteristics UFII : Unique Fixture, 2 nd Generation UFII Design Characteristics 1. Hybrid SLA Surface Treatment 2. Tapered-Straight Combined Shape 3. Hex Internal Connection 4. Dual Morse Tapered Connection (11 Morse)

More information

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants

Very small abutment head easy and secure handling. Ankylos. The SmartFix concept. Prosthetic solution on angled implants Very small abutment head easy and secure handling Ankylos The SmartFix concept Prosthetic solution on angled implants Stable prosthetic fit The area supporting the prosthesis is extended distally by the

More information

INNOVATION! The incisive choice

INNOVATION! The incisive choice R E S T R I C T E D M E S I O D I S TA L S P A C E INNOVATION! The incisive choice 2 anthogyr 2.8 A TRULY NARROW DIAMETER... An innovative concept axiom 2.8 is an implant designed specifically for restorations

More information

Instructions for Use DENTAL IMPLANTS

Instructions for Use DENTAL IMPLANTS HAHN TAPERED IMPLANT GUIDED SURGERY SYSTEM Instructions for Use English General Information IMPORTANT INFORMATION PLEASE READ Caution: U.S. federal law restricts this device to sale by, or on the order

More information

SuperLine & Implantium Surgical / Prosthesis Manual

SuperLine & Implantium Surgical / Prosthesis Manual SuperLine & Implantium Surgical / Prosthesis Manual SuperLine & Implantium SURGICAL MANUAL Surgical Drill Sequence 04 Drilling Depth Guide 06 Fixture Connection 08 Installation Procedure & Warnings 09

More information

cement-retained single crowns using cementable abutments

cement-retained single crowns using cementable abutments cement-retained single crowns using cementable abutments cement-retained restorations cement-retained single crowns using cementable abutments Cement-retained implant restorations are similar to conventional

More information

The Multi-unit Abutments of the CE-Series are indicated for Nobel Biocare / NobelReplace Tapered. The current implant diameters have to be attended.

The Multi-unit Abutments of the CE-Series are indicated for Nobel Biocare / NobelReplace Tapered. The current implant diameters have to be attended. Instructions for Use Multi-Unit Abutment with Screw Description: Multi-Unit Abutment with screws for series CC-Series, CE-Series, CV- Series, CF-Series, CH-Series, CK-Series, CL-Series, CN-Series, CR-Series,

More information

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations

Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations Abutments for all indications. Individualized CAD/CAM and prefabricated implant restorations 2 Abutments for all indications Comprehensive and effective the Nobel Biocare abutment portfolio. The Nobel

More information

For the oral rehabilitation

For the oral rehabilitation For the oral rehabilitation Contents For superstructures Chapter 1 Overview of prosthetic modes 1. Prosthetic modes of the PLATON system 2. Factors involved in prosthetic design Chapter 2 Cement-retained

More information

» For multi-unit restorations -

» For multi-unit restorations - » For multi-unit restorations - conventional or digital «Multi-Unit Abutments 2 The Multi-unit product range is being contiunally expanded to include other abutment series. Available for a large number

More information

Transforming the Implant Industry. Broadest Product Line Highest Quality-Best Value

Transforming the Implant Industry. Broadest Product Line Highest Quality-Best Value Transforming the Industry Broadest Product Line Highest Quality-Best Value System Overview 2010 Table of Contents Legacy System pages 2-5 Compatible with *Zimmer Screw-Vent Legacy3 3.2/3.0 Legacy3 3.7/3.5

More information

Locator retained mandibular complete prosthesis (isy Implant System)

Locator retained mandibular complete prosthesis (isy Implant System) Locator retained mandibular complete prosthesis (isy Implant System) Mucosa-supported complete prostheses with poor fit greatly reduce people's quality of life. This is why the importance of implant-supported

More information

INDEX. General informations. Pg.2. JDNow concept. Pg.3. Surgical procedure. Pg.9. Pg.17. Prosthetic procedure. Instruments and accessories. Pg.

INDEX. General informations. Pg.2. JDNow concept. Pg.3. Surgical procedure. Pg.9. Pg.17. Prosthetic procedure. Instruments and accessories. Pg. Pg.1 INDEX General informations JDNow concept Surgical procedure Prosthetic procedure Instruments and accessories Product catalog Pg.2 Pg.3 Pg.9 Pg.17 Pg.21 Pg.24 Index Pg.2 GENERAL INFORMATIONS Read this

More information

GINGIVAL LEVEL implant

GINGIVAL LEVEL implant G GINGIVA EVE implant GINGIVA EVE implant Implant characteristics page 04 ental implant page 06 Titanium healing abutment page 07 Prosthetic components page 07 Cemented prosthesis procedure page 10 O ball

More information

Step-by-Step Cemented Bridge Using Using CPK Abutments. Internal Hex. Implant System

Step-by-Step Cemented Bridge Using Using CPK Abutments. Internal Hex. Implant System 4. 6. Step-by-Step Cemented Bridge Using Using CPK Abutments Internal Hex. Implant System MIS Corporation. All rights reserved. Published by MIS, which reserves the right to ameliorate the products described

More information

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l

Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l Treatment Options for Restoring Edentulous Jaws using One- and Two-Piece Implants from Implant Direct Int l Two-Piece ReActive Tri-Lobe Implants with Multi-Unit Abutments One-Piece ScrewIndirect Implants

More information

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants

Multi-Unit Abutment System SIC Safe on Four. Optimum use of available bone by angled placement of implants Multi-Unit Abutment System SIC Safe on Four Optimum use of available bone by angled placement of implants Multi-Unit Abutment System SIC Safe on Four Safe on Four The SIC Safe on Four system is a further

More information

For technical assistance: Tel Working time: 8.30 am pm

For technical assistance: Tel Working time: 8.30 am pm I For technical assistance: Tel. +39 059 392827 Working time: 8.30 am - 5.30 pm Index JD Digital solutions for Intraoral Scanning JD Implant Libraries JD Guided Surgery Kit JD Surgical Guide and 3D Model

More information

QZ-Implant TRINON. Bone level implant with hexagonal internal cone connection

QZ-Implant TRINON. Bone level implant with hexagonal internal cone connection QZ-Implant Information Components are updated periodically, check with your local Trinon partner on current models Please follow Instructions for Use for individual components Images are not to scale see

More information

MagDen System Magnetic Implant. Catalog/Manual

MagDen System Magnetic Implant. Catalog/Manual MagDen System Magnetic Implant Catalog/Manual Contents MagDen Concept 3 MagDen Properties 4 RBM Surface 5 MagDen Fixture 6 MagDen Keeper & Magnet 7 MagDen Surgical Kit 8 MagDen Drilling Depth Guide 9 MagDen

More information

S i m p l i c I t y, c o m f o r t, a e s t h e t i c s. axiom. The new dimension

S i m p l i c I t y, c o m f o r t, a e s t h e t i c s. axiom. The new dimension S i m p l i c I t y, c o m f o r t, a e s t h e t i c s axiom The new dimension 2 Implants by anthogyr axiom, t h e n e w g e n e r a t i o n i m p l a n t axiom characteristics represent the perfect synthesis

More information

FOR C1 & V3 IMPLANTS STEP-BY-STEP GUIDED SURGICAL PROCEDURE

FOR C1 & V3 IMPLANTS STEP-BY-STEP GUIDED SURGICAL PROCEDURE FOR C1 & V3 IMPLANTS STEP-BY-STEP GUIDED SURGICAL PROCEDURE 1 2 LOGICAL LAYOUT 1 Example: C1 Implant Ø4.20 / 11.5L ; Soft Bone Ø4.20 / 11.5L MG-D0624 MG-D1124 MG-D1133 MG-D1137 2 Example: Implant C1 Ø4.20

More information