1 CLINICAL SCIENCES Agreement of the Heidelberg Retina Tomograph II Macula Edema Module With Fundus Biomicroscopy in Diabetic Maculopathy Mila Kisilevsky, MD; Christopher Hudson, PhD; John G. Flanagan, PhD; Ravi Krishna Nrusimhadevara, MD; Kit Guan, OD; Tien Wong, BSc; Mark Mandelcorn, MD; Wai-Ching Lam, MD; Robert G. Devenyi, MD Objectives: To estimate the agreement between the macular edema maps (MEMs) of the Retina Module of the Heidelberg Retina Tomograph II (Heidelberg Engineering, Heidelberg, Germany) and contact lens fundus biomicroscopy (FB) and to assess the influence of combining MEM data with the results of short-wavelength automated perimetry (SWAP) and fluorescein angiography (FA) on diagnostic test performance. Design: Prospective, observational case series. Methods: Twenty patients (2 eyes) with diabetic retinopathy with or without clinically manifest macular edema (11 and 9 eyes, respectively) were enrolled. All patients underwent full ophthalmologic examination and also MEM assessment, SWAP, and FA. Results: Using FB as the gold standard, the agreement between the MEMs and FB was very good (Kendall coefficient of concordance,.8). Macular edema maps showed good agreement with FA and SWAP (Kendall coefficient,.64 and.65). Virtually all of the edematous areas detected with MEM but not seen clinically had decreased sensitivity on SWAP and/or fluorescein leakage. Conclusions: Macular edema maps demonstrated very good agreement with FB. Combining the results of FA and SWAP with those of the MEMs provided supporting evidence of concomitant blood-retinal barrier leakage and visual dysfunction, respectively, in areas of early retinal thickening. Prospective studies are ongoing to fully assess the diagnostic test performance of MEMs in the detection of early and progressive diabetic macular edema. Arch Ophthalmol. 26;124: Author Affiliations: Multi-Disciplinary Laboratory for the Research of Sight-Threatening Diabetic Retinopathy, Department of Ophthalmology and Vision Science, University of Toronto, Ontario (Drs Kisilevsky, Hudson, Flanagan, Nrusimhadevara, Guan, Mandelcorn, Lam, and Devenyi and Mr Wong); School of Optometry, University of Waterloo, Ontario (Drs Kisilevsky, Hudson, Flanagan, and Nrusimhadevara and Mr Wong). DIABETIC RETINOPATHY IS the leading cause of visual impairment and blindness in the working population of Western countries. 1 Macular edema in particular remains the most common cause of visual impairment and blindness among people with diabetes. 2,3 The current clinical gold standard for the detection of diabetic macular edema (DME) is contact lens stereo fundus biomicroscopy (FB), but subtle changes in retinal thickness are difficult to detect and it is even more challenging to determine change in retinal thickening over time. 4 The first-choice treatment currently available for DME is laser photocoagulation, which is implemented when there is a threat of central vision loss. 5 Conventional laser treatment is effective but may cause complications such as visible laser scars that can enlarge, 6 choroidal neovascularization, 7 and visual field loss. 8 There are 2 possible approaches to reduce potential adverse effects of laser treatment. One is to use less destructive treatment such as subthreshold diode micropulse laser photocoagulation. 9 The other is to improve the accuracy of edema diagnosis, which will allow the start of treatment earlier and the application of photocoagulation in a more precise manner to a smaller area of retina. In fact, the combination of both approaches promises to improve the overall outcome of laser treatment. Furthermore, validation of any new treatment modality in clinical trials will require shorter follow-up periods and smaller sample sizes if objective, sensitive, and reliable techniques for the detection and monitoring of DME are available. Any new technique for the quantitative assessment of DME needs to have a similar, and ideally improved, diagnostic test performance to that of clinical examination. Tong and coworkers 1 have proposed the use of the Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany) as a screening modality for the detection of sightthreatening diabetic maculopathy and a new scoring system for macular image assessment. The authors reported high specificity and good sensitivity of HRT topographic assessment in a group of diabetic (REPRINTED) ARCH OPHTHALMOL / VOL 124, MAR Downloaded From: on 7/2/ American Medical Association. All rights reserved.
2 METHODS r = 15 µm r = 1 µm r = 5 µm Figure 1. Nine-sector grid used for the assessment of macular edema map images. patients with heterogenous retinopathy characteristics. 1 Other studies from our laboratory using the edema index methodology have demonstrated good spatial agreement between areas of elevated edema index and clinically detected areas of retinal thickening in diabetic patients. 11 In addition, we have demonstrated good correlation of the HRT edema index with change of visual function, including logmar visual acuity, conventional automated static perimetry, and short-wavelength automated perimetry (SWAP) in patients undergoing grid laser treatment for clinically significant macular edema. 12 Furthermore, SWAP has been shown to be a sensitive tool for the detection of DME. In many cases, the localized field loss detected by SWAP corresponded to, but was greater than, the area of edema on clinical mapping. 13 The macular edema maps (MEMs) of the Retina Module of the HRT II were subsequently developed. More recently, the HRT II MEMs have been demonstrated to offer improved sensitivity (and comparable specificity) in the detection of DME when compared with the Retinal Thickness Analyzer. 14 The HRT II MEMs have been demonstrated to have good repeatability in patients with diabetic retinopathy and edema. 14 In our experience, however, MEMs tend to detect larger areas of edema than clinical assessment and also on occasion show elevated edema index values in patients without any clinically evident retinal thickening. 14 We hypothesized that the assessment of visual function (ie, SWAP) and bloodretinal barrier integrity (ie, fluorescein angiography [FA]) in cases of controversy between MEMs and clinical assessment may help to confirm or deny the validity of the MEM findings. The aims of the study were to estimate the agreement of the MEMs with contact lens stereo FB and to assess the influence of combining MEM data with the results of SWAP and FA on diagnostic test performance. We compared the results of MEMs with contact lens stereo FB, FA, and SWAP in a group of diabetic patients with and without clinically evident DME. Diabetic patients were enrolled from the retina clinics at the Toronto Western Hospital, University Health Network, Toronto, Ontario. The study was approved by the research ethics board of the University Health Network, University of Toronto, and the Office of Research Ethics, University of Waterloo, Ontario. The research followed the tenets set out in the Declaration of Helsinki. Informed consent was obtained from all subjects. The sample comprised 2 patients (14 men, 6 women) with a mean±sd age of 59.15±7.1 years (range, years). Nineteen patients had type 2 diabetes, and 1 patient had type 1 diabetes. The mean±sd duration of diabetes was 15±8.8 years (range, 4-42 years). Inclusion criteria comprised mild-tomoderate diabetic retinopathy, an age range of 4 to 7 years, and a logmar visual acuity of.3 or better. Exclusion criteria comprised lenticular opacities that would impact substantially on fundus visualization, refractive error greater than ±6. diopter sphere and/or ±2.5 diopter cylinder, any other eye disorder or disease apart from diabetic retinopathy, previous laser treatment or surgery in the study eye, a family history of glaucoma in a first-degree relative, central nervous system or psychiatric diseases, systemic medications with known central nervous system effects, and unreliable automated perimetry results as defined by the Humphrey Field Analyzer II (Carl Zeiss Meditec Inc, Dublin, Calif). All patients underwent a full ophthalmologic evaluation, including logmar visual acuity and refraction, slitlamp examination with contact lens stereo FB, FA, SWAP, and HRT II MEM. Pupillary dilation using 1.% Mydriacyl (Alcon, Fort Worth, Tex) was undertaken for all procedures apart from logmar visual acuity and refraction. All tests but FA were performed on the same day. One eye of each patient was randomly assigned to the study. MEMs OF THE HRT II The HRT II is a confocal laser scanning system for the acquisition and analysis of 3-dimensional images of the posterior segment of the eye. The laser source employed in the HRT II is a diode laser with a wavelength of 67 nm. A 3-dimensional image is generated as a series of 16 to 64 consecutive and equidistant (ie, 16 images every 1 mm of scan depth) 2-dimensional optical section images. Each of the 2-dimensional images consists of picture elements. The scan field is Three sequential tomographic images are automatically scanned on initiation of image acquisition and are averaged to display a mean topography image. The edema index analysis developed by Flanagan and Hudson has been incorporated within the HRT II as part of the Retina Module. The HRT II Retina Module software computes reflectivity, topography, signal width, and edema maps. A full description of the edema index methodology has been detailed previously. 14 The image acquisition was performed by experienced operators and 3 sets (ie, 3 3 images) of HRT II images were obtained for each patient. The HRT II MEM images were subsequently assessed by an experienced MEM user. One of the 3 sets of images was chosen based on best image quality. The edema map was divided into 9 sectors using a grid formed by 3 concentric circles centered on the fovea and 4 radial lines extending outward from the innermost of these in the 45, 135, 225, and 315 meridians (9-Zone Analysis). The radius of the innermost circle was 5 µm, and the radii of the second and the third circles were 1 µm and 15 µm, respectively. The total field size for the analysis was approximately 1 in diameter (Figure 1). To minimize error in the positioning of the 9-sector grid on the MEM image, the foveal center was located on the basis of clinical and (REPRINTED) ARCH OPHTHALMOL / VOL 124, MAR Downloaded From: on 7/2/ American Medical Association. All rights reserved.
3 A B C D E F Figure 2. This case demonstrates very good agreement between macular edema maps (MEMs) and fundus biomicroscopy (89%), fairly good agreement between MEMs and fluorescein angiography (67%), and good agreement between MEMs and short-wavelength automated perimetry (78%). A, Fundus photograph. B, Fundus biomicroscopy interpretation. C, Fluorescein angiography. D, Macular Edema Module reflectivity map. E, Macular Edema Module edema map. F, Short-wavelength automated perimetry analysis. FA assessments and marked on an acetate sheet that detailed each individual s retinal vascular pattern. This also ensured consistency in the positioning of the grid across all imaging modalities (FB, FA, and MEM) (Figure 2). The presence or absence of elevated edema index values was documented for each of the 9 sectors; 18 sectors (ie, 9 sectors 2 patients) were analyzed for the group as a whole. SHORT-WAVELENGTH AUTOMATED PERIMETRY The macular visual field of each patient was determined with program 1-2 of the Humphrey Field Analyzer II using shortwavelength stimulus parameters and a standard full-threshold strategy. All subjects had previously undertaken at least 1 SWAP field, thus minimizing learning effects. The SWAP was assessed using a pointwise horizontal and vertical hemifield asymmetry analysis that has been detailed previously, 11 thereby negating the influence of prereceptoral absorption. Abnormality was defined as 7 or more contiguous stimulus locations with statistically significant negative asymmetries. From the total of 68 stimulus locations, only 32 central points corresponding to a 1 field diameter were included in the comparative analysis. These 32 stimulus locations were divided into 9 predefined sectors approximately corresponding to the areas of the MEM (Figure 3). Each predefined sector comprised 4 points (4 points falling on the radial lines were double counted and included into the analysis of both adjacent areas). A given grid sector was considered abnormal if it contained at least 2 statistically significant points with negative SWAP asymmetry values, apart from the central 5-µm radius sector where only 1 abnormal point was required. Figure 3. Grid used for the assessment of short-wavelength automated perimetry results. CONTACT LENS STEREO FB Contact lens stereo FB was performed by retinal specialists masked to MEM results. For each patient, all areas of edema were drawn on an acetate sheet that detailed each individual s (REPRINTED) ARCH OPHTHALMOL / VOL 124, MAR Downloaded From: on 7/2/ American Medical Association. All rights reserved.
4 Table 1. Distribution of Abnormal Test Results* Patient No. FB MEMs FA SWAP * denotes abnormal test results; no entry indicates normal results. retinal vascular pattern while the patient was situated at the slitlamp. The 9-sector grid was overlaid on the sheet detailing the areas of retinal thickening to allocate the presence or absence of DME in each sector of the grid. FLUORESCEIN ANGIOGRAPHY Fluorescein angiography was performed on all research patients. The interval between FA and the study tests was dictated by routine clinical care of the patient and ranged from the same day to 2 weeks (median, 8 weeks). Late phase and early phase angiograms were used to determine the presence and location of FA leakage according to Early Treatment Diabetic Retinopathy Study Research criteria. 15 All areas of leakage were drawn on an acetate sheet and sectors of involvement were documented in a similar manner to that of FB. STATISTICAL ANALYSIS Descriptive statistics such as mean, range, and standard deviation were calculated for case characteristics. Percentage of agreement and the Kendall coefficient of concordance were calculated using the pooled sectors to compare FB results with those of MEMs, SWAP, and FA. RESULTS Eleven patients had clinically evident macular edema and 9 patients had no edema by FB. Fourteen patients had an abnormal HRT II MEM. Fourteen patients had localized visual field loss using SWAP. Eleven patients had leakage on FA (Table 1). Across the group, on average 1.85 of 9 sectors were noted as abnormal on FB. Fluorescein angiography, MEMs, and SWAP detected more abnormal sectors than FB (Table 2). Table 2. Number of Areas Defined as Abnormal Test Total Abnormal Sectors, No. The HRT II MEMs and FB showed very good agreement in identifying areas with DME with a Kendall coefficient of concordance of.8 (P.1). There was substantial agreement between MEMs and FA (Kendall coefficient,.64; P.1) as well as between MEMs and SWAP (Kendall coefficient,.65; P.1) (Table 3). Comparing MEMs with FB as the gold standard, MEMs demonstrated a sensitivity of 92% and specificity of 85%. The mean number of sectors without clinically evident retinal thickening and defined by MEMs as abnormal was 1.1 of 9. Similarly, FA detected a mean of 1.2 additional abnormal sectors while SWAP detected a mean of 1.75 sectors. The mean number of sectors with clinically evident retinal thickening and defined by MEMs as normal was.15 of 9, whereas for FA and SWAP, the mean numbers of normal sectors were 1.5 and.85, respectively (Table 4). Analyzing only the sectors that were detected as abnormal by MEMs but that did not show retinal thickening on FB, the localized SWAP sensitivity loss was observed in 13 of 22 such sectors and FA leakage in 9 of 22 sectors, and decreased SWAP sensitivity and/or FA leakage was observed in 16 of 22 sectors (Table 5). COMMENT Abnormal Sectors per Patient, Mean, No. (Range) FB 37/ /9 (-5) MEMs 56/18 2.8/9 (-9) FA 4/18 2/9 (-8) SWAP 55/ /9 (-6) Fundus biomicroscopy remains the clinical gold standard for the assessment of DME, but it relies on the subjective interpretation of thickening of an essentially transparent retina, has large interobserver variability, and lacks objective quantification. The development of a reproducible, objective technique to identify retinal edema and to monitor change in edema is widely recognized to be essential for the improved clinical management of DME per se and for the evaluation of new therapeutic protocols. 16 Currently available imaging technologies to assess DME include optical coherence tomography (OCT), the Retinal Thickness Analyzer, and the Macular Edema Module of the HRT II. Optical coherence tomography is widely used for the assessment of macular disease with different etiologies. Optical coherence tomography has very good agreement with contact lens FB, 17 although it has been reported to be prone to artifacts arising in the process of macular surface map reconstruction. 18 The Retinal Thickness Analyzer works on the principle of slitlamp FB and in our experience shows poor sensitivity and moderate specificity in the assessment of the retinal thickness of diabetic patients. 14 (REPRINTED) ARCH OPHTHALMOL / VOL 124, MAR Downloaded From: on 7/2/ American Medical Association. All rights reserved.
5 Table 3. Agreement Between MEMs and FB, FA, and SWAP (in Number of Areas) Tests Agreement Total Sectors, No. Sectors per Patient, Mean, No. Kendall Coefficient MEMs vs FB Positive 34/18 1.7/9.8 (P.1) Negative 121/18 6.5/9 MEMs vs FA Positive 24/18 1.2/9.64 (P.1) Negative 117/ /9 MEMs vs SWAP Positive 31/ /9.65 (P.1) Negative 1/18 5/9 The Macular Edema Module represents a relatively new and promising application for the detection and follow-up of DME. The Macular Edema Module generates an edema index that reflects increase in retinal thickness and reduction in retinal reflectivity due to changes in retinal refractive index in areas of edema. The reliance of the Macular Edema Module technique on 2 optical principles for the detection of edema is thought to increase the sensitivity. 11 Compared to OCT, the HRT II has inferior axial resolution; however, it has far superior spatial resolution and thereby avoids the undersampling in the periphery of the image that is inherent in the OCT macular maps. This study and previous work from our laboratory 14 demonstrated that MEMs offer very good sensitivity and similar specificity in detecting macular edema compared to FB. The Macular Edema Module generates high spatial resolution topographic edema maps and, unlike any of the current imaging technologies, offers facility for the precise alignment of images acquired over successive visits, an essential feature for any sequential analysis. The extent to which all imaging technologies are influenced by the ocular media, corneal drying, and excessive eye movements is uncertain, but experience suggests that such factors impact the diagnostic test performance of every modality. The lower specificity of MEMs when compared with FB may be due to the fact that the Macular Edema Module detects edema-related changes that are not yet clinically manifest using FB. The failure of FB to correlate with alternative objective techniques for the assessment of retinal thickness has been reported by previous investigators. 17,19 Brown et al 17 proposed the term subclinical edema for such cases. The assessment of the blood-retinal barrier integrity and short-wavelength pathway function in areas of possible subclinical DME was used in our study to validate the MEM results. The presence of edema suggests blood-retinal barrier breakdown, and areas of retinal edema largely, although not completely, coincide with areas of fluorescein leakage. Similarly, localized SWAP sensitivity loss has been shown to correspond with the clinical mapping of the area of DME, but the extent of this loss was found to be generally greater than that suggested by clinical assessment. 13 Although SWAP visual field defects in diabetic maculopathy may also be caused by ischemic damage in the absence of DME, 2 the larger area of defect most likely reflects subtle changes in retinal thickness, particularly given the clinical characteristics of the patients described in this study. Table 4. Disagreement Between FB, MEMs, FA, and SWAP Tests Total Sectors, No. (of 18) Sectors per Patient, Mean, No. (of 9) MEMs positive/fb negative 22/ /7.15 MEMs negative/fb positive 3/37.15/1.85 FA positive/fb negative 24/ /7.15 FA negative/fb positive 21/37 1.5/1.85 SWAP positive/fb negative 35/ /7.15 SWAP negative/fb positive 17/37.85/1.85 Table 5. Agreement Between Modalities (MEMs, SWAP, FA) for Additional Abnormal Areas Found Within the MEMs Test Total Sectors, No. Sectors per Patient, Mean, No. MEMs positive/fb negative 22/ /7.15 SWAP agreed with MEMs 13/22.65/1.1 FA agreed with MEMs 9/22.45/1.1 SWAP and/or FA agreed with MEMs 16/22.8/1.1 We assessed the MEMs using a 9-sector grid rather than define the image as normal or abnormal as a whole. This approach allowed more precise assessment of MEMs and a topographic comparison of different techniques used for the detection of abnormality associated with the occurrence of DME. Macular edema maps showed excellent agreement with FB but tended to show a greater extent of abnormality. Almost all sectors identified as abnormal using MEMs but normal with FB and revealed some abnormality on SWAP and/or FA, suggesting the presence of functional and structural changes. Thus, combining the findings of FA and SWAP with the MEM scans provided supporting evidence of abnormality in areas of subclinical retinal edema. Ideally, a prospective study with a larger group of patients will determine whether these positive MEM findings will progress to clinically evident retinal edema. Such a study, also incorporating OCT, is currently in progress in our laboratory. (REPRINTED) ARCH OPHTHALMOL / VOL 124, MAR Downloaded From: on 7/2/ American Medical Association. All rights reserved.
6 Submitted for Publication: October 5, 24; accepted March 14, 25. Correspondence: Christopher Hudson, PhD, University of Toronto, Toronto Western Hospital, Main Pavilion 6-26, 399 Bathurst St, Toronto, Ontario, Canada M5T 2S8 Financial Disclosure: Dr Flanagan has received payment as a consultant and has received research funding from Heidelberg Engineering, Heidelberg, Germany. Funding/Support: This work was funded by the Canadian Institutes of Health Research, Ottawa, Ontario (New Investigator Award, C.H.; Operating Grant, C.H. and J.G.F.); and by a Premier s Research Excellence Award (C.H.). REFERENCES 1. Klein R, Klein BE, Moss SE, Cruickshanks KJ. The Wisconsin epidemiology study of diabetic retinopathy, VII: the 14 year incidence and progression of diabetic retinopathy and associated risk factors in type I diabetes. Ophthalmology. 1998; 15: Klein R, Klein BE, Moss SE, Davis MD, DeMets DL. The Wisconsin epidemiologic study of diabetic retinopathy, IV: diabetic macular edema. Ophthalmology. 1984;91: Klein R, Moss SE, Klein BE, Davis MD, DeMets DL. The Wisconsin epidemiologic study of diabetic retinopathy, I: the incidence of macular edema. Ophthalmology. 1989;96: Hudson C, Flanagan JG, McLeod D. A clinical vision science perspective of the management of diabetic macular oedema: focus on diabetic retinopathy. Excerpta Medica. 1999;6: Early Treatment Diabetic Retinopathy Study Research Group. Early photocoagulation for diabetic retinopathy: ETDRS report number 9. Ophthalmology. 1991; 98(suppl 5): Early Treatment Diabetic Retinopathy Study Research Group. Focal photocoagulation treatment of diabetic macular edema. Relationship of treatment effect to fluorescein angiographic and other retinal characteristics at baseline: ETDRS report No. 19. Arch Ophthalmol. 1995;113: Lewis H, Schachat AP, Haimann MH, et al. Choroidal neovascularization after laser photocoagulation for diabetic macular edema. Ophthalmology. 199; 97: Hudson C, Flanagan JG, Turner GS, Chen HC, Young LB, McLeod D. Influence of laser photocoagulation for clinically significant diabetic macular oedema (DMO) on short-wavelength and conventional automated perimetry. Diabetologia. 1998; 41: Luttrull JK, Musch DC, Mainster MA. Subthreshold diode micropulse photocoagulation for the treatment of clinically significant diabetic macular oedema. Br J Ophthalmol. 25;89: Tong L, Ang A, Vernon SA, et al. Sensitivity and specificity of a new scoring system for diabetic macular oedema detection using a confocal laser imaging system. Br J Ophthalmol. 21;85: Hudson C, Flanagan JG, Turner GS, McLeod D. Scanning laser tomography Z- profile signal width as an objective index of retinal thickening due to macular oedema. Br J Ophthalmol. 1998;82: Hudson C, Flanagan JG, Turner GS, Chen HC, Young L, McLeod D. Correlation of a scanning laser derived oedema index and visual function following grid laser treatment for diabetic macular oedema. Br J Ophthalmol. 23;87: Hudson C, Flanagan JG, Turner GS, Chen HC, Young LB, McLeod D. Shortwavelength sensitive visual field loss in patients with clinically significant diabetic macular oedema. Diabetologia. 1998;41: Guan K, Hudson C, Flanagan JG. Comparison of Heidelberg Retina Tomograph II and Retinal Thickness Analyzer in the assessment of DME. Invest Ophthalmol Vis Sci. 24;45: Early Treatment Diabetic Retinopathy Study Research Group. Classification of diabetic retinopathy from fluorescein angiograms: ETDRS report number 11. Ophthalmology. 1991;98: Bresnick GH. Diabetic macular edema. Ophthalmology. 1986;93: Brown JC, Solomon SD, Bressler SB, Schachat AP, DiBernardo C, Bressler NM. Detection of diabetic foveal edema: contact lens biomicroscopy compared with optical coherence tomography. Arch Ophthalmol. 24;122: Ray R, Stinnett SS, Jaffe GJ. Evaluation of image artifact produced by optical coherence tomography of retinal pathology. Am J Ophthalmol. 25;139: Shahidi M, Ogura Y, Blair N, Rusin MM, Zeimer R. Retinal thickness analysis for quantitative assessment of diabetic macular edema. Arch Ophthalmol. 1991; 19: Remky A, Arend O, Hendricks S. Short-wavelength automated perimetry and capillary density in early diabetic maculopathy. Invest Ophthalmol Vis Sci. 2; 41: Call for Papers Archives of Ophthalmology will publish articles on men s health and ophthalmology in conjunction with a JAMA theme issue on the same topic in November 26. Manuscripts received by June 1, 26, will have the best chance for consideration for this theme issue. (REPRINTED) ARCH OPHTHALMOL / VOL 124, MAR Downloaded From: on 7/2/ American Medical Association. All rights reserved.
Andrew J. Barkmeier, MD; Benjamin P. Nicholson, MA; Levent Akduman, MD
c l i n i c a l s c i e n c e Effectiveness of Laser Photocoagulation in Clinically Significant Macular Edema With Focal Versus Diffuse Parafoveal Thickening on Optical Coherence Tomography Andrew J. Barkmeier,
More informationThe Measure of Confidence
Heidelberg_936357.qxd:Layout 1 5/9/08 12:01 PM 12:02 Page 1 (Cyan (Magenta (Yellow (Black (UV Five Powerful Solutions to Fit Your Practice PowerCheck Glaucoma FastCheck+ GPS Software and Retina Edema Index
More informationCLINICAL SCIENCES. Repeatability and Reproducibility of Fast Macular Thickness Mapping With Stratus Optical Coherence Tomography
CLINICAL SCIENCES Repeatability and Reproducibility of Fast Macular Thickness Mapping With Stratus Optical Coherence Tomography Antonio Polito, MD; Michele Del Borrello, MD; Miriam Isola, MHS; Nicola Zemella,
More informationStudy of clinical significance of optical coherence tomography in diagnosis & management of diabetic macular edema
Original Research Article Study of clinical significance of optical coherence tomography in diagnosis & management of diabetic macular edema Neha Kantilal Desai 1,*, Somesh Vedprakash Aggarwal 2, Sonali
More informationOptical Coherence Tomography Fast versus Regular Macular Thickness Mapping in Diabetic Retinopathy
Original Paper DOI: 10.1159/000127830 Received: March 18, 2007 Accepted after revision: July 9, 2007 Published online: April 25, 2008 Optical Coherence Tomography Fast versus Regular Macular Thickness
More informationQuantitative assessment of macular thickness in normal subjects and patients with diabetic retinopathy by scanning retinal thickness analyser
54 Department of Ophthalmology, Osaka Rosai Hospital, Osaka, Japan Y Oshima K Emi S Yamanishi M Motokura Department of Ophthalmology, Osaka University Medical School, Osaka, Japan Y Oshima Correspondence
More informationIs OCT-A Needed As An Investigative Tool During The Management Of Diabetic Macular Edema
Is OCT-A Needed As An Investigative Tool During The Management Of Diabetic Macular Edema Ayman M Khattab MD, FRCS Professor of Ophthalmology Cairo University Diabetic Macular Edema (DME) Diabetic macular
More informationEvaluation of Changes of Macular Thickness in Diabetic Retinopathy after Cataract Surgery
pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2011;25(4):238-242 DOI: 10.3341/kjo.2011.25.4.238 Evaluation of Changes of Macular Thickness in Diabetic Retinopathy after Cataract Surgery Original
More informationVISUAL OUTCOME IN DIABETIC MACULAR EDEMA AFTER GRID LASER TREATMENT
The Professional Medical Journal DOI: 10.17957/TPMJ/16.2856 ORIGINAL PROF-2856 VISUAL OUTCOME IN DIABETIC MACULAR EDEMA AFTER GRID LASER TREATMENT 1. MBBS.FCPS Assistant Professor Ophthalmology Independent
More informationReproducibility of volumetric measurements of normal maculae with the Heidelberg retina tomograph
884 Department of Ophthalmology, Queen s Medical Centre, University Hospital, Nottingham NG7 2UH H J Zambarakji JEEvans WMKAmoaku SAVernon Correspondence to: Mr S A Vernon, Ophthalmology Directorate, Queen
More informationDiabetic retinopathy accounts for much of the visual impairment
Diabetic Macular Edema Assessed with Optical Coherence Tomography and Stereo Fundus Photography Charlotte Strøm, 1 Birgit Sander, 1 Nicolai Larsen, 1,2 Michael Larsen, 1 and Henrik Lund-Andersen 1 PURPOSE.
More informationOptical Coherence Tomograpic Features in Idiopathic Retinitis, Vasculitis, Aneurysms and Neuroretinitis (IRVAN)
Columbia International Publishing Journal of Ophthalmic Research (2014) Research Article Optical Coherence Tomograpic Features in Idiopathic Retinitis, Vasculitis, Aneurysms and Neuroretinitis (IRVAN)
More informationCLINICAL SCIENCES. Felipe A. Medeiros, MD; Linda M. Zangwill, PhD; Christopher Bowd, PhD; Robert N. Weinreb, MD
CLINICAL SCIENCES Comparison of the GDx VCC Scanning Laser Polarimeter, HRT II Confocal Scanning Laser Ophthalmoscope, and Stratus OCT Optical Coherence Tomograph for the Detection of Glaucoma Felipe A.
More informationSeiji T. Takagi, Yoshiyuki Kita, Asuka Takeyama, and Goji Tomita. 1. Introduction. 2. Subjects and Methods
Ophthalmology Volume 2011, Article ID 914250, 5 pages doi:10.1155/2011/914250 Clinical Study Macular Retinal Ganglion Cell Complex Thickness and Its Relationship to the Optic Nerve Head Topography in Glaucomatous
More information3/16/2018. Perimetry
Perimetry The normal visual field extends further away from fixation temporally and inferiorly than superiorly and nasally. From the center of the retina this sensitivity decreases towards the periphery,
More informationRetinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography
Original Article Philippine Journal of OPHTHALMOLOGY Retinal Nerve Fiber Layer Measurements in Myopia Using Optical Coherence Tomography Dennis L. del Rosario, MD and Mario M. Yatco, MD University of Santo
More informationClinical Study Choroidal Thickness in Eyes with Unilateral Ocular Ischemic Syndrome
Hindawi Publishing Corporation Journal of Ophthalmology Volume 215, Article ID 62372, 5 pages http://dx.doi.org/1.1155/215/62372 Clinical Study Choroidal Thickness in Eyes with Unilateral Ocular Ischemic
More informationMethod for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma.
Method for comparing visual field defects to local RNFL and RGC damage seen on frequency domain OCT in patients with glaucoma. Donald C. Hood 1,2,* and Ali S. Raza 1 1 Department of Psychology, Columbia
More informationJMSCR Vol 06 Issue 12 Page December 2018
www.jmscr.igmpublication.org Impact Factor (SJIF): 6.379 Index Copernicus Value: 79.54 ISSN (e)-2347-176x ISSN (p) 2455-0450 DOI: https://dx.doi.org/10.18535/jmscr/v6i12.39 Central Macular Thickness analysis
More informationThe Natural History of Diabetic Retinopathy and How Primary Care Makes A Difference
The Natural History of Diabetic Retinopathy and How Primary Care Makes A Difference We will discuss - How exactly does blood sugar control affect retinopathy? - What are other factors that we measure in
More informationPRIMUS 200 from ZEISS The essential OCT
PRIMUS 200 from ZEISS The essential OCT Seeing beyond the surface. ZEISS PRIMUS 200 // INNOVATION MADE BY ZEISS Clear Visualization. Advanced Technology. Reliability. Essential elements of your first OCT.
More informationR&M Solutions
Mohamed Hosny El-Bradey, MD., Assistant Professor of Ophthalmology, Tanta University. Wael El Haig, MD., Professor of Ophthalmology. Zagazeeg University. 1 Myopic CNV is considered the most common vision
More informationAdvances in OCT Murray Fingeret, OD
Disclosures Advances in OCT Murray Fingeret, OD Consultant Alcon, Allergan, Bausch & Lomb, Carl Zeiss Meditec, Diopsys, Heidelberg Engineering, Reichert, Topcon Currently Approved OCT Devices OCT Devices
More informationUse of Scanning Laser Ophthalmoscope Microperimetry in Clinically Significant Macular Edema in Type 2 Diabetes Mellitus
Use of Scanning Laser Ophthalmoscope Microperimetry in Clinically Significant Macular Edema in Type 2 Diabetes Mellitus Fumihiko Mori, Satoshi Ishiko, Norihiko Kitaya, Taiichi Hikichi, Eiichi Sato, Akira
More informationOCT Assessment of the Vitreoretinal Relationship in CSME
December 2007 Sonia Rani John et al. - IFIS 375 ORIGINAL ARTICLE OCT Assessment of the Vitreoretinal Relationship in CSME Dr. Manoj S. DNB FRCS, Dr. Unnikrishnan Nair MS DO FRCS, Dr. Gargi Sathish MS Introduction
More informationSubclinical Diabetic Macular Edema Study
Diabetic Retinopathy Clinical Research Network Subclinical Diabetic Macular Edema Study Version 2.0 March 21, 2006 Subclinical DME Protocol v2 0 3-21-06.doc Table of Contents Chapter 1. Background Information
More informationDo You See What I See!!! Shane R. Kannarr, OD
Do You See What I See!!! Shane R. Kannarr, OD skannarr@kannarreyecare.com Define Specialty Testing Additional Test to: Prove/Disprove Diagnosis To monitor progression of a condition To document a condition
More informationParafoveal Scanning Laser Polarimetry for Early Glaucoma Detection
Yamanashi Med. J. 18(1), 15~ 20, 2003 Original Article Parafoveal Scanning Laser Polarimetry for Early Glaucoma Detection Satoshi KOGURE, Yoshiki TODA, Hiroyuki IIJIMA and Shigeo TSUKAHARA Department of
More informationFundus Fluorescein Angiography in Diabetic Retinopathy: Correlation of Angiographic Findings to the Clinical Maculopathy Abstract: Purpose:
IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 15, Issue 2 Ver. XII (Feb. 2016), PP 80-88 www.iosrjournals.org Fundus Fluorescein Angiography in Diabetic
More informationCirrus TM HD-OCT. Details define your decisions
Cirrus TM HD-OCT Details define your decisions 2 With high-definition OCT Carl Zeiss Meditec takes you beyond standard spectral domain Built on 10 years experience at the vanguard of innovation, Carl Zeiss
More informationPRIMUS 200 from ZEISS The essential OCT
EN 00_00I The contents of the brochure may differ from the current status of approval of the product in your country. Please contact your regional representative for more information. Subject to change
More informationROLE OF LASER PHOTOCOAGULATION VERSUS INTRAVITREAL TRIAMCINOLONE ACETONIDE IN ANGIOGRAPHIC MACULAR EDEMA IN DIABETES MELLITUS
ORIGINAL ARTICLE ROLE OF LASER PHOTOCOAGULATION VERSUS INTRAVITREAL TRIAMCINOLONE ACETONIDE IN ANGIOGRAPHIC MACULAR EDEMA IN DIABETES MELLITUS Aggarwal Somesh VP 1, Shah Sonali N 2, Bharwada Rekha M 3,
More informationIn its initial report, the Early Treatment Diabetic Retinopathy. A Severity Scale for Diabetic Macular Edema Developed from ETDRS Data
A Severity Scale for Diabetic Macular Edema Developed from ETDRS Data Ronald E. Gangnon, 1,2 Matthew D. Davis, 3 Larry D. Hubbard, 3 Lloyd M. Aiello, 4 Emily Y. Chew, 5 Frederick L. Ferris III, 5 Marian
More informationRETINAL NERVE FIBER LAYER
CLINICAL SCIENCES The Effect of Scan Diameter on Retinal Nerve Fiber Layer Thickness Measurement Using Stratus Optic Coherence Tomography Giacomo Savini, MD; Piero Barboni, MD; Michele Carbonelli, MD;
More informationCOMPARISON OF INTRAVITREAL TRIAMCINOLONE INJECTION VS LASER PHOTOCOAGULATION IN ANGIOGRAPHIC MACULAR EDEMA IN DIABETIC RETINOPATHY
Original Article COMPARISON OF INTRAVITREAL TRIAMCINOLONE INJECTION VS LASER PHOTOCOAGULATION IN ANGIOGRAPHIC MACULAR EDEMA IN DIABETIC RETINOPATHY Aggarwal Somesh V 1, Shah Sonali N 2, Bharwada Rekha
More informationA retrospective nonrandomized study was conducted at 3
Department of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University College of Medicine 1, Seoul, Korea Hangil Eye Hospital 2, Incheon, Korea Seoul National University Bundang Hospital 3, Seongnam,
More informationZEISS AngioPlex OCT Angiography. Clinical Case Reports
Clinical Case Reports Proliferative Diabetic Retinopathy (PDR) Case Report 969 PROLIFERATIVE DIABETIC RETINOPATHY 1 1-year-old diabetic female presents for follow-up of proliferative diabetic retinopathy
More informationIl contributo dell'angio-oct: valutazione integrata della componente nervosa e vascolare della malattia glaucomatosa
SIMPOSIO G.O.A.L. - LE NUOVE FRONTIERE DIAGNOSTICHE E LE LINEE DI INDIRIZZO AMBULATORIALI DEL GLAUCOMA Coordinatore e moderatore: D. Mazzacane Presidente: L. Rossetti Il contributo dell'angio-oct: valutazione
More informationGanglion cell complex scan in the early prediction of glaucoma
Original article in the early prediction of glaucoma Ganekal S Nayana Super Specialty Eye Hospital and Research Center, Davangere, Karnataka, India Abstract Objective: To compare the macular ganglion cell
More informationDiabetic Retinopathy and Peripapillary Retinal Thickness
pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2010;24(1):16-22 DOI: 10.3341/kjo.2010.24.1.16 Original Article Diabetic Retinopathy and Peripapillary Retinal Thickness Hee Yoon Cho 1, Dong Hoon
More informationAutomated Detection of Clinically Significant Macular Edema by Grid Scanning Optical Coherence Tomography
Automated Detection of Clinically Significant Macular Edema by Grid Scanning Optical Coherence Tomography Srinivas R. Sadda, MD, 1 Ou Tan, PhD, 1 Alexander C. Walsh, MD, 1 Joel S. Schuman, MD, 2 Rohit
More informationRecalcitrant Diabetic Macular Oedema: Therapeutic Options
December 2007 A. Giridhar et al. - Recalcitrant DME 451 CONSULTATION S E C T I O N Recalcitrant Diabetic Macular Oedema: Therapeutic Options Dr. Cyrus M Shroff 1, Dr. N S Muralidhar 2, Dr. R Narayanan
More informationClinical biomicroscopy versus fluorescein angiography: Effectiveness and sensitivity in detecting diabetic retinopathy
European Journal of Ophthalmology / Vol. 17 no. 1, 2007 / pp. 84-88 Clinical biomicroscopy versus fluorescein angiography: Effectiveness and sensitivity in detecting diabetic retinopathy S.S. KHALAF, M.D.
More informationDiagnosis and treatment of diabetic retinopathy. Blake Cooper MD Ophthalmologist Vitreoretinal Surgeon Retina Associates Kansas City
Diagnosis and treatment of diabetic retinopathy Blake Cooper MD Ophthalmologist Vitreoretinal Surgeon Retina Associates Kansas City Disclosures Consulted for Novo Nordisk 2017,2018. Will be discussing
More informationLinking structure and function in glaucoma
CET CONTINUING Sponsored by 1 CET POINT Linking structure and function in glaucoma 50 Dr Samantha McGinnigle PhD, BSc (Hons), MCOptom, AHEA This article will give an overview of the latest imaging technology
More informationmeasure of your overall performance. An isolated glucose test is helpful to let you know what your sugar level is at one moment, but it doesn t tell you whether or not your diabetes is under adequate control
More informationNovel imaging techniques for diabetic macular edema
Documenta Ophthalmologica 97: 341 347, 1999. T.J. Wolfensberger (ed.), Conference Proceedings of the 2 nd International Symposium on Macular Edema, 137 143. 2000 Kluwer Academic Publishers. Printed in
More informationQuantitative analysis of central visual field defects in macular edema using three-dimensional computer-automated threshold Amsler grid testing
Graefes Arch Clin Exp Ophthalmol (2009) 247:165 170 DOI 10.1007/s00417-008-0971-8 RETINAL DISORDERS Quantitative analysis of central visual field defects in macular edema using three-dimensional computer-automated
More informationResearch Article Repeatability of Perimacular Ganglion Cell Complex Analysis with Spectral-Domain Optical Coherence Tomography
Ophthalmology Volume 2015, Article ID 605940, 5 pages http://dx.doi.org/10.1155/2015/605940 Research Article Repeatability of Perimacular Ganglion Cell Complex Analysis with Spectral-Domain Optical Coherence
More informationTHE PREVALENCE OF CAUSES FOR DIABETIC RETINOPATHY USING MATHEMATICAL MODELS
International Journal of Advanced Research in Engineering and Technology (IJARET) Volume 9, Issue 6, November-December 2018, pp. 167 171, Article ID: IJARET_09_06_017 Available online at http://www.iaeme.com/ijaret/issues.asp?jtype=ijaret&vtype=9&itype=6
More informationCase Report Inherent Challenges in Managing Long Standing Refractory Diabetic Macular Edema
Cronicon OPEN ACCESS EC OPHTHALMOLOGY Case Report Inherent Challenges in Managing Long Standing Refractory Diabetic Macular Edema V Swetha E Jeganathan 1,2 * and Karen Madill 3 1 Department of Ophthalmology,
More informationIncorporating OCT Angiography Into Patient Care
Incorporating OCT Angiography Into Patient Care Beth A. Steele, OD, FAAO OCT A: Introduction Isolates microvascular circulation from OCT image data Axial resolution = 5 microns (i.e. fine capillaries visible)
More informationRETINAL THICKENING MAY BE PRESENT IN A NUMBER. B-scan Ultrasonography for the Detection of Macular Thickening METHODS
B-scan Ultrasonography for the Detection of Macular Thickening JAMES C. LAI, MD, SANDRA S. STINNETT, DRPH, AND GLENN J. JAFFE, MD PURPOSE: To report the sensitivity and specificity of B-scan ultrasonography
More informationDiabetic retinopathy (DR) progressively
FOCUS ON DIABETIC MACULAR EDEMA * Frederick L. Ferris III, MD ABSTRACT The current state of treatment for diabetic macular edema (DME) is focused on slowing the rate of vision loss through assessment of
More informationGlaucoma: Diagnostic Modalities
Glaucoma: Diagnostic Modalities - Dr. Barun Kumar Nayak, Dr. Sarika Ramugade Glaucoma is a leading cause of blindness in the world, especially in older people. Early detection and treatment by ophthalmologist
More informationCase Report Increase in Central Retinal Edema after Subthreshold Diode Micropulse Laser Treatment of Chronic Central Serous Chorioretinopathy
Case Reports in Ophthalmological Medicine Volume 2015, Article ID 813414, 4 pages http://dx.doi.org/10.1155/2015/813414 Case Report Increase in Central Retinal Edema after Subthreshold Diode Micropulse
More informationRole of OCT in the diagnosis and follow up of diabetic macular edema
Seminars in Ophthalmology 0882-0538/02/1701-019$16.00 2002, Vol. 17, No. 1, pp. Swets & Zeitlinger Role of OCT in the diagnosis and follow up of diabetic macular edema Giacomo Panozzo, Elena Gusson, arbara
More informationHHS Public Access Author manuscript Ophthalmic Surg Lasers Imaging Retina. Author manuscript; available in PMC 2016 January 14.
High-Speed Ultrahigh-Resolution OCT of Bruch s Membrane in Membranoproliferative Glomerulonephritis Type 2 Mehreen Adhi, MD, Sarah P. Read, MD, PhD, Jonathan J. Liu, PhD, James G. Fujimoto, PhD, and Jay
More informationClinically Significant Macular Edema (CSME)
Clinically Significant Macular Edema (CSME) 1 Clinically Significant Macular Edema (CSME) Sadrina T. Shaw OMT I Student July 26, 2014 Advisor: Dr. Uwaydat Clinically Significant Macular Edema (CSME) 2
More informationFluorescein Angiography Compared to Three-Dimensional Measurements by the Retinal Thickness Analyzer in Classic Choroidal Neovascularization
Original Paper DOI: 1.1159/99245 Received: June 1, 26 Accepted after revision: November 15, 26 Published online: February 2, 27 Fluorescein Angiography Compared to Three-Dimensional Measurements by the
More informationSTANDARD AUTOMATED PERIMETRY IS A GENERALLY
Comparison of Long-term Variability for Standard and Short-wavelength Automated Perimetry in Stable Glaucoma Patients EYTAN Z. BLUMENTHAL, MD, PAMELA A. SAMPLE, PHD, LINDA ZANGWILL, PHD, ALEXANDER C. LEE,
More informationOCT Angiography: The Next Step in Retinal Imaging Jonathan Zelenak D.O.
OCT Angiography: The Next Step in Retinal Imaging Jonathan Zelenak D.O. Hillsdale Hospital Michigan State University Overview Evolution of OCT How does OCT angiography work? Clinical examples Potential
More informationSAFETY OF TRANSFOVEAL SUBTHRESHOLD DIODE MICROPULSE LASER FOR FOVEA-INVOLVING DIABETIC MACULAR EDEMA IN EYES WITH GOOD VISUAL ACUITY
SAFETY OF TRANSFOVEAL SUBTHRESHOLD DIODE MICROPULSE LASER FOR FOVEA-INVOLVING DIABETIC MACULAR EDEMA IN EYES WITH GOOD VISUAL ACUITY JEFFREY K. LUTTRULL, MD,* STEPHEN H. SINCLAIR, MD Purpose: To determine
More informationOCT Angiography in Primary Eye Care
OCT Angiography in Primary Eye Care An Image Interpretation Primer Julie Rodman, OD, MS, FAAO and Nadia Waheed, MD, MPH Table of Contents Diabetic Retinopathy 3-6 Choroidal Neovascularization 7-9 Central
More informationMacular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma
Med. J. Cairo Univ., Vol. 83, No. 2, September: 67-72, 2015 www.medicaljournalofcairouniversity.net Macular Ganglion Cell Complex Measurement Using Spectral Domain Optical Coherence Tomography in Glaucoma
More informationCirrus TM HD-OCT. Details defi ne your decisions
Cirrus TM HD-OCT Details defi ne your decisions 2 With high-defi nition OCT Carl Zeiss Meditec takes you beyond standard spectral domain Built on 10 years experience at the vanguard of innovation, Carl
More informationINTRODUCTION J. DAWCZYNSKI, E. KOENIGSDOERFFER, R. AUGSTEN, J. STROBEL. Department of Ophthalmology, University Hospital Jena, Jena - Germany
European Journal of Ophthalmology / Vol. 17 no. 3, 2007 / pp. 363-367 Anterior segment optical coherence tomography for evaluation of changes in anterior chamber angle and depth after intraocular lens
More informationIntravitreal versus Posterior Subtenon Injection of Triamcinolone Acetonide for Diabetic Macular Edema
Intravitreal versus Posterior Subtenon Injection of Triamcinolone Acetonide for Diabetic Macular Edema Young Jae Choi, MD, In Kyung Oh, MD, Jae Ryung Oh, MD, PhD, Kuhl Huh, MD, PhD Department of Ophthalmology,
More informationMulti-Modal Longitudinal Evaluation of Subthreshold Laser Lesions in Human Retina, Including Scanning Laser Ophthalmoscope-Adaptive Optics Imaging
EXPERIMENTAL SCIENCE Multi-Modal Longitudinal Evaluation of Subthreshold Laser Lesions in Human Retina, Including Scanning Laser Ophthalmoscope-Adaptive Optics Imaging Edward H. Wood, MD; Theodore Leng,
More informationFundus Autofluorescence. Jonathan A. Micieli, MD Valérie Biousse, MD
Fundus Autofluorescence Jonathan A. Micieli, MD Valérie Biousse, MD The retinal pigment epithelium (RPE) has many important functions including phagocytosis of the photoreceptor outer segments Cone Rod
More informationDifferences between Non-arteritic Anterior Ischemic Optic Neuropathy and Open Angle Glaucoma with Altitudinal Visual Field Defect
pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2015;29(6):418-423 http://dx.doi.org/10.3341/kjo.2015.29.6.418 Original Article Differences between Non-arteritic Anterior Ischemic Optic Neuropathy
More informationNoel de Jesus Atienza, MD, MSc and Joseph Anthony Tumbocon, MD
Original Article Philippine Journal of OPHTHALMOLOGY Diagnostic Accuracy of the Optical Coherence Tomography in Assessing Glaucoma Among Filipinos. Part 1: Categorical Outcomes Based on a Normative Database
More informationCLINICAL SCIENCES. Volumetric Analysis of Macular Edema by Scanning Laser Tomography in Immune Recovery Uveitis
CLINICAL SCIENCES Volumetric Analysis of Macular Edema by Scanning Laser Tomography in Immune Recovery Uveitis Dirk-Uwe G. Bartsch, PhD; Ajay Aurora, MD; Nuttawut Rodanant, MD; Lingyun Cheng, MD; William
More informationCorporate Medical Policy
Corporate Medical Policy Optical Coherence Tomography (OCT) Anterior Segment of the Eye File Name: Origination: Last CAP Review: Next CAP Review: Last Review: optical_coherence_tomography_(oct)_anterior_segment_of_the_eye
More informationOphthalmology. Caring For Your Eyes. Jurong Medical Centre
Ophthalmology Caring For Your Eyes Jurong Medical Centre Your eyes and you At Jurong Medical Centre, we have a dedicated team of ophthalmologists that specialise in treating a wide range of acute and chronic
More informationWidefield Retinal Imaging with Auto Fluorescence Technology in the Optometric Practice
Widefield Retinal Imaging with Auto Fluorescence Technology in the Optometric Practice This course will define ultra-widefield retinal imaging and autofluorescence for the attendee. Will show how it is
More informationOCT in Diabetic Macular Edema and its Correlation with Flourescein Angiography
Uvea OCT in Diabetic Macular Edema and its Correlation with Flourescein Angiography Kirti Jaisingh MS Kirti Jaisingh MS, Yashpal Goel* MS, Kshitij Aditya** DO * Guru Nanak Eye Centre, New Delhi ** Baba
More informationDiabetic Management beyond traditional risk factors and LDL-C control: Can we improve macro and microvascular risks?
Retinopathy Diabetes has a negative effect on eyes in many ways, increasing the risk of cataracts for example, but the most common and serious ocular complication of diabetes is retinopathy. Diabetic retinopathy
More informationStructural examina.on: Imaging
ManaMa: Glaucoma Structural examina.on: Imaging Luís Abegão Pinto, MD, PhD Department of Ophthalmology CHLC Lisbon Faculty of Medicine, Lisbon University 1 11-10- 2013 Structural changes Qualitative changes
More informationA Comparative Study of Age Related Macular Degeneration In Relation To SD-OCTand Fundus Photography.
IOSR Journal of Dental and Medical Sciences (IOSR-JDMS) e-issn: 2279-0853, p-issn: 2279-0861.Volume 14, Issue 11 Ver. III (Nov. 2015), PP 33-37 www.iosrjournals.org A Comparative Study of Age Related Macular
More informationTechnologies and Methods for Visualizing the Retina
Transcript Details This is a transcript of an educational program accessible on the ReachMD network. Details about the program and additional media formats for the program are accessible by visiting: https://reachmd.com/programs/revealing-retina/technologies-and-methods-for-visualizing-theretina/3663/
More informationDiabetic Retinopathy Clinical Research Network
Diabetic Retinopathy Clinical Research Network Comparison of Time Domain OCT and Spectral Domain OCT Retinal Thickness Measurement in Diabetic Macular Edema Version 1.0 June 16, 2009 comparison of td vs
More informationPERIMETRIC LONG-TERM FOLLOW-UP OF DIABETIC CYSTOID MACULAR EDEMA AFTER LASER TREATMENT EXTENDED TO THE FOVEAL AVASCULAR ZONE
Perimetric long-term follow-up of diabetic cystoid macular edema 477 PERIMETRIC LONG-TERM FOLLOW-UP OF DIABETIC CYSTOID MACULAR EDEMA AFTER LASER TREATMENT EXTENDED TO THE FOVEAL AVASCULAR ZONE FRANCESCO
More informationVisualize. Analyze. Personalize. OCT + OCTA
Visualize. Analyze. Personalize. OCT + OCTA A New Approach to Protecting Vision AngioVue OCT Angiography brings valuable new information to clinical practice. Non-invasive visualization of retinal vasculature.
More informationRama Vadapalli * 1, Vankadara Naga Suresh 2. Online Access and Article Informtaion. Original Research Article
Original Research Article An Interventional Follow up Study to Determine the Effect of Nepafenac 0.1% in Macular thickness in Patients who had Undergone Cataract Surgery as Determined By OCT Rama Vadapalli
More informationDiabetic maculopathy 11/ An update on. Miss Vasuki Sivagnanavel
Miss Vasuki Sivagnanavel Consultant Ophthalmologist An update on Diabetic maculopathy Despite advances in the management of diabetes, diabetic retinopathy is already the commonest cause of blindness among
More informationReproducibility of Nerve Fiber Layer Thickness Measurements by Use of Optical Coherence Tomography
Reproducibility of Nerve Fiber Layer Thickness Measurements by Use of Optical Coherence Tomography Eytan Z. Blumenthal, MD, 1 Julia M. Williams, BS, 1 Robert N. Weinreb, MD, 1 Christopher A. Girkin, MD,
More informationOptical coherence tomography in diabetic macular edema: patterns and related risk factors
Original article Optical coherence tomography in diabetic macular edema: patterns and related risk factors Mohammadreza Ahmadpour-Baghdadabad Masoudreza Manaviat Ahmad Shojaoddiny-Ardekani Yazd Diabetes
More informationComparative study of new imaging technologies for the diagnosis of glaucoma: Protocol Approved by the Ethics Committee
Comparative study of new imaging technologies for the diagnosis of glaucoma: Protocol Approved by the Ethics Committee HTA 09/22/111. Applicants: Augusto Azuara-Blanco (CI), Jennifer Burr,, Rodolfo Hernández,
More informationTissue-Sparing MicroPulse Photocoagulation
Tissue-Sparing MicroPulse Photocoagulation What is MicroPulse? A technology that finely controls thermal elevation by: chopping a CW beam into a train of repetitive microsecond pulses allowing tissue to
More informationT herapeutic retinal photocoagulation has been practised
1173 EXTENDED REPORT Subthreshold micropulse diode laser treatment in diabetic macular oedema M L Laursen, F Moeller, B Sander, A K Sjoelie... See end of article for authors affiliations... Correspondence
More informationNIH Public Access Author Manuscript JAMA Ophthalmol. Author manuscript; available in PMC 2013 September 10.
NIH Public Access Author Manuscript Published in final edited form as: JAMA Ophthalmol. 2013 May ; 131(5): 693 694. doi:10.1001/jamaophthalmol.2013.692. Effect of Intravitreous Anti Vascular Endothelial
More informationStructural changes of the anterior chamber following cataract surgery during infancy
Structural changes of the anterior chamber following cataract surgery during infancy Matthew Nguyen, Emory University Marla Shainberg, Emory University Allen Beck, Emory University Scott Lambert, Emory
More informationNon-arteritic anterior ischemic optic neuropathy (NAION) with segmental optic disc edema. Jonathan A. Micieli, MD Valérie Biousse, MD
Non-arteritic anterior ischemic optic neuropathy (NAION) with segmental optic disc edema Jonathan A. Micieli, MD Valérie Biousse, MD A 75 year old white woman lost vision in the inferior part of her visual
More informationComparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis OCT
pissn: 1011-8942 eissn: 2092-9382 Korean J Ophthalmol 2011;25(3):166-173 DOI: 10.3341/kjo.2011.25.3.166 Original Article Comparison of Retinal Nerve Fiber Layer Thickness between Stratus and Spectralis
More informationTHE OCULAR histoplasmosis
CLINICAL SCIENCES Reactivation of Inflammatory Lesions in Ocular Histoplasmosis David Callanan, MD; Gary E. Fish, MD, JD; Rajiv Anand, MD Background: Active inflammation has not been traditionally associated
More informationOptical Coherence Tomography Grid Decentration and Its Effect on Macular Thickness Measurements
Optical Coherence Tomography Grid Decentration and Its Effect on Macular Thickness Measurements Khalil Ghasemi Falavarjani, MD 1 Joobin Khadamy, MD 2 Nasser Karimi, MD, MPH 2 Anis Alsadat Jazayeri, MD
More informationThe use of a high-intensity laser to create an anastomotic
Case Report 866 Laser Chorioretinal Venous Anastomosis for Progressive Nonischemic Central Retinal Vein Occlusion Chih-Hsin Chen, MD; Chien-Hsiung Lai 1, MD; Hsi-Kung Kuo, MD The use of high or medium-intensity
More informationDiabetic Retinopathy Clinical Research Network
Diabetic Retinopathy Clinical Research Network An Observational Study of the Development of Diabetic Macular Edema Following Scatter Laser Photocoagulation Version 1.4 June 24, 2005 PRP Obs Study Protocol
More informationIn 1990 our group first described reticular pseudodrusen as a. Choroidal Changes Associated with Reticular Pseudodrusen. Retina
Retina Choroidal Changes Associated with Reticular Pseudodrusen Giuseppe Querques, 1,2 Lea Querques, 1,2 Raimondo Forte, 1 Nathalie Massamba, 1 Florence Coscas, 1 and Eric H. Souied 1 PURPOSE. To analyze
More information